WorldWideScience

Sample records for monitor measurement values

  1. Adding Shareholder Value through Project Performance Measurement, Monitoring & Control

    NARCIS (Netherlands)

    M.M. Akalu; J.R. Turner (Rodney)

    2002-01-01

    textabstractWe present the various views and methods of measuring and controlling project performance, and factors affecting a project. The review indicates that there is a shift in the type and understanding of factors of project success or failure. However, the presence of various measurement

  2. Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards.

    Science.gov (United States)

    Deschamps, Ann E; De Geest, Sabina; Vandamme, Anne-Mieke; Bobbaers, Herman; Peetermans, Willy E; Van Wijngaerden, Eric

    2008-09-01

    Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.

  3. Value activity monitoring

    NARCIS (Netherlands)

    de Alencar Silva, P.

    2013-01-01

    Current value modeling ontologies are grounded on the economic premise that profit sharing is a critical condition to be assessed during the configuration of a value constellation. Such a condition ought to be reinforced through a monitoring mechanism design, since a value model expresses only

  4. Player Monitoring in Indoor Team Sports: Concurrent Validity of Inertial Measurement Units to Quantify Average and Peak Acceleration Values

    Directory of Open Access Journals (Sweden)

    Mareike Roell

    2018-02-01

    Full Text Available The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia were compared to the results of a 3D motion analysis (MA system (Vicon Motion Systems, Oxford, UK during selected standardized movement simulations in an indoor laboratory (n = 56. A low-pass filtering method for gravity correction (LF and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF, Kalman-Filter (KF] were implemented and compared with MA system data. Significant differences (p < 0.05 were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6% and KF (RMSE = 0.15; CV = 3.8% both compared to the LF method (RMSE = 1.14; CV = 47.6% regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 – 17.8%. Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that

  5. Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system.

    Science.gov (United States)

    Adamson, Philip B; Magalski, Anthony; Braunschweig, Frieder; Böhm, Michael; Reynolds, Dwight; Steinhaus, David; Luby, Allyson; Linde, Cecilia; Ryden, Lars; Cremers, Bodo; Takle, Teri; Bennett, Tom

    2003-02-19

    This study examined the characteristics of continuously measured right ventricular (RV) hemodynamic information derived from an implantable hemodynamic monitor (IHM) in heart failure patients. Hemodynamic monitoring might improve the day-to-day management of patients with chronic heart failure (CHF). Little is known about the characteristics of long-term hemodynamic information in patients with CHF or how such information relates to meaningful clinical events. Thirty-two patients with CHF received a permanent RV IHM system similar to a single-lead pacemaker. Right ventricular systolic and diastolic pressures, heart rate, and pressure derivatives were continuously measured for nine months without using the data for clinical decision-making or management of patients. Data were then made available to clinical providers, and the patients were followed up for 17 months. Pressure characteristics during optimal volume, clinically determined volume-overload exacerbations, and volume depletion events were examined. The effect of IHM on hospitalizations was examined using the patients' historical controls. Long-term RV pressure measurements had either marked variability or minimal time-related changes. During 36 volume-overload events, RV systolic pressures increased by 25 +/- 4% (p < 0.05) and heart rate increased by 11 +/- 2% (p < 0.05). Pressure increases occurred in 9 of 12 events 4 +/- 2 days before the exacerbations requiring hospitalization. Hospitalizations before using IHM data for clinical management averaged 1.08 per patient year and decreased to 0.47 per patient-year (57% reduction, p < 0.01) after hemodynamic data were used. Long-term ambulatory pressure measurements from an IHM may be helpful in guiding day-to-day clinical management, with a potentially favorable impact on CHF hospitalizations.

  6. A method for realistic assessment of the environmental load following an accident in a nuclear facility taking into consideration measured values from environment monitoring

    International Nuclear Information System (INIS)

    Geiss, H.

    1985-01-01

    To enable consideration of time and space variations of source properties and of meteorological parameters, the quasi-stationary computational programme MUSEMET was developed for risk assessment. It was the modified for use in the prognosis of radiation exposure following accidents, in view of on-line registration of current meteorological data in 5- or 10-minute increments. By direct time-dependent continuous measurement of turbulence parameters a classification of diffusion categories is no more required. The diffusion parameters needed for this quasi-instationary Gaussian model are also determined continuously from turbulence measurements. MUSEMET and/or the follow-up programme MUSEDOS allow the determination of time- and location-dependent individual dose rates received by inhalation, γ- and β-submersion, γ-radiation from contaminated floors and by ingestion. An illustration is made in time-dependent form on a graphic display showing isodose lines together with a map of the site surroundings, or in tables. The anticipated values are continuously compared with the measured values from environment monitoring. γ-spectrometric measurements in particular can be exploited for calculations designed to enable accurate statements on the source, and the prognosis can be corrected accordingly. (orig./HP) [de

  7. Effluent monitoring: Its purpose and value

    International Nuclear Information System (INIS)

    Schoen, A.A.

    1978-01-01

    The purpose of effluent monitoring is described in terms of the primary objectives, the most important of which is to verify that the facility is functioning as it was designed and that the waste treatment and effluent control systems are performing as planned and expected. The object of a monitoring programme should be periodically re-examined to ensure that the programme serves a contemporary purpose. The value of the effluent monitoring programme is determined by the extent to which users of the monitoring data, i.e. the operator, the regulating authorities and the public, accept the result as indicating that the plant is operating safely, and in an environmentally acceptable manner. The credibility of the monitoring results is therefore the most important factor determining the value of an effluent monitoring programme. (author)

  8. Measuring the value of intangibles

    DEFF Research Database (Denmark)

    Clausen, Saskia; Hirth, Stefan

    2016-01-01

    We propose a new earnings-based measure for the value of intangibles. To validate this measure, we compare it to commonly used proxies for intangible intensity, such as R&D expenses. While R&D expenses measure the investment in new intangibles, our new measure gauges the productivity of already e...... of our intangible-intensity measure in the context of capital structure. We find that more intangible-intensive firms have lower leverage. © 2016 Elsevier B.V....

  9. Measuring value sensitivity in medicine.

    Science.gov (United States)

    Ineichen, Christian; Christen, Markus; Tanner, Carmen

    2017-01-28

    Value sensitivity - the ability to recognize value-related issues when they arise in practice - is an indispensable competence for medical practitioners to enter decision-making processes related to ethical questions. However, the psychological competence of value sensitivity is seldom an explicit subject in the training of medical professionals. In this contribution, we outline the traditional concept of moral sensitivity in medicine and its revised form conceptualized as value sensitivity and we propose an instrument that measures value sensitivity. We developed an instrument for assessing the sensitivity for three value groups (moral-related values, values related to the principles of biomedical ethics, strategy-related values) in a four step procedure: 1) value identification (n = 317); 2) value representation (n = 317); 3) vignette construction and quality evaluation (n = 37); and 4) instrument validation by comparing nursing professionals with hospital managers (n = 48). We find that nursing professionals recognize and ascribe importance to principle-related issues more than professionals from hospital management. The latter are more likely to recognize and ascribe importance to strategy-related issues. These hypothesis-driven results demonstrate the discriminatory power of our newly developed instrument, which makes it useful not only for health care professionals in practice but for students and people working in the clinical context as well.

  10. Microfabricated fuel heating value monitoring device

    Science.gov (United States)

    Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM

    2010-05-04

    A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

  11. Space weather monitoring with neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian [Christian-Albrechts-Universitaet zu Kiel (Germany)

    2013-07-01

    Space Weather affects many areas of the modern society, advance knowledge about space weather events is important to protect personnel and infrastructure. Cosmic Rays (CR) measurements by ground-based Neutron Monitors are influenced by Coronal Mass Ejections (CME), the intensity of the ever present Cosmic Rays is reduced in a Forbush decrease (Fd). In the case of very energetic CMEs, the measured intensity can be significantly increased in a Ground Level Enhancement (GLE). By detecting the anisotropy of the CR environment, a CME can be detected hours before it arrives at Earth. During a GLE the high-energy particles from the Sun can be detected before the more abundant lower energy particles arrive at Earth, thus allowing to take protective measures. Since the beginning of the Neutron Monitor Database (NMDB) project, which has been started in 2008 with funding from the European Commission, real-time data from Neutron Monitors around the world has been made available through one web-portal. We have more than doubled the number of stations providing data since the start of the project to now over 30 stations. The effectiveness of the ALERT applications which are based on NMDB data has been shown by the recent GLE71. We present different applications through which the measurements and different data products are accessible.

  12. Environmental radioactivity. Measurement and monitoring

    International Nuclear Information System (INIS)

    2009-11-01

    The contribution on environmental radioactivity covers the following issues: natural and artificial radioactivity; continuous monitoring of radioactivity; monitoring authorities and measurement; radioactivity in the living environment; radioactivity in food and feeding stuff; radioactivity of game meat and wild-growing mushrooms; radioactivity in mines; radioactivity in the research center Rossendorf.

  13. Reconstructing weak values without weak measurements

    International Nuclear Information System (INIS)

    Johansen, Lars M.

    2007-01-01

    I propose a scheme for reconstructing the weak value of an observable without the need for weak measurements. The post-selection in weak measurements is replaced by an initial projector measurement. The observable can be measured using any form of interaction, including projective measurements. The reconstruction is effected by measuring the change in the expectation value of the observable due to the projector measurement. The weak value may take nonclassical values if the projector measurement disturbs the expectation value of the observable

  14. Assessing the value of structural health monitoring

    DEFF Research Database (Denmark)

    Thöns, S.; Faber, Michael Havbro

    2013-01-01

    Structural Health Monitoring (SHM) systems are designed for assisting owners and operators with information and forecasts concerning the fitness for purpose of structures and building systems. The benefit associated with the implementation of SHM may in some cases be intuitively anticipated...... as their responses and performances over their life-cycle. In addition, the quality of monitoring and the performance of possible remedial actions triggered by monitoring results are modeled probabilistically.The consequences accounted for, in principle include all consequences associated with the performance...

  15. Performance Measures, Benchmarking and Value.

    Science.gov (United States)

    McGregor, Felicity

    This paper discusses performance measurement in university libraries, based on examples from the University of Wollongong (UoW) in Australia. The introduction highlights the integration of information literacy into the curriculum and the outcomes of a 1998 UoW student satisfaction survey. The first section considers performance indicators in…

  16. Monitoring coordinate measuring machines by calibrated parts

    International Nuclear Information System (INIS)

    Weckenmann, A; Lorz, J

    2005-01-01

    Coordinate measuring machines (CMM) are essential for quality assurance and production control in modern manufacturing. Due to the necessity of assuring traceability during the use of CMM, interim checks with calibrated objects carried out periodically. For this purpose usually special artefacts like standardized ball plates, hole plates, ball bars or step gages are measured. Measuring calibrated series parts would be more advantageous. Applying the substitution method of ISO 15530-3: 2000 such parts can be used. It is less cost intensive and less time consuming than measuring expensive special standardized objects in special programmed measurement routines. Moreover, the measurement results can directly compare with the calibration values; thus, direct information on systematic measurement deviations and uncertainty of the measured features are available. The paper describes a procedure for monitoring horizontal-arm CMMs with calibrated sheet metal series parts

  17. On the value of structural health monitoring

    DEFF Research Database (Denmark)

    Faber, Michael Havbro; Thöns, Sebastian

    2014-01-01

    in the fields of SHM and the quantification of value of information as well as the identification of typical situations in structural engineering in which SHM has the potential to provide value beyond its costs. Subsequently, the theoretical framework which allows for the quantification of the value...... of information collected through SHM systems is developed and elaborated. It is shown how the value of information can be quantified to support the assessment and optimization of decisions on whether and how to implement SHM. To illustrate the use of the developed theoretical framework for evaluating the benefit...

  18. Value of monitoring in road network management

    NARCIS (Netherlands)

    Zouch, M.; Courage, W.; Napoles-Morales, O.

    2014-01-01

    We present a framework for road network management to assist road authorities in maintenance budget estimations and long-term maintenance strategies definition. Information about road conditions is obtained from monitoring. Available data are used to estimate and update prediction of degradation

  19. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by

  20. Measurement units of physical values

    International Nuclear Information System (INIS)

    Debraine, P.

    1955-01-01

    The aim of this paper is twofold: 1) to give an analysis of the formation conditions of the various systems of units, 2) to show how the practical problems involving changes of units can be solved. This analysis leads to the conception of 'types' of systems, which is very useful to clarity the question of rationalized and non rationalized systems. The second point which consists essentially in: 1) finding the relationship between the measures of a given quantity in different systems, 2) deriving practical formulas, 3) deriving formulas in various 'types' of systems, is made easier by use of sets of: * definition formulas, * transformation formulas, * units of the various practical systems with useful numerical information covering the following fields: ** geometry, ** kinematics, ** mechanics, ** electricity and magnetism, ** thermodynamics, ** radiation, ** photometry, These sets being printed on coloured paper can be easily found. A number of numerical examples (21) show in a detailed way how to solve the various problems likely to occur. A chapter is particularly devoted to the Giorgi MKS system. (author) [fr

  1. Measuring and monitoring energy poverty

    International Nuclear Information System (INIS)

    Pachauri, Shonali; Spreng, Daniel

    2011-01-01

    This article undertakes a review of alternative measures and indicators of energy poverty targeted to specific audiences and for particular purposes. At the national and international scales there have been some efforts for constructing measures of energy poverty. However, much more needs to be done to develop an internationally consistent measurement framework and to put in place data collection systems that will enable regular reporting. At the programme and project level, indicator systems by necessity need to be designed for specific purposes. Nevertheless, the article proposes that in many instances it is desirable to widen the scope of metrics used for designing and evaluating policies and programmes. In the past, monitoring and evaluation indicators have focused largely on outputs, service delivery or dissemination. Central to the recommendations laid out in the paper is the call for widening the focus of evaluation and necessity to design indicators that adequately assess the needs of beneficiaries and describe the living conditions of families and communities, who are targeted by such programmes and initiatives. - Highlights: ► Consistent measurement frameworks and regular data collection systems on energy poverty are needed. ► Metrics used for designing and evaluating energy access programmes should be widened. ► Indicators that adequately assess needs and describe living conditions of targeted beneficiaries are required.

  2. Towards a biological monitoring guidance value for acrylamide.

    Science.gov (United States)

    Sams, C; Jones, K; Warren, N; Cocker, J; Bell, S; Bull, P; Cain, M

    2015-08-19

    Acrylamide is classified as a potential human carcinogen and neurotoxicant. Biological monitoring is a useful tool for monitoring worker exposure. However, other sources of exposure to acrylamide (including cigarette smoke and diet) also need to be considered. This study has performed repeat measurements of the urinary mercapturic acids of acrylamide (AAMA) and its metabolite glycidamide (GAMA) and determined globin adducts in 20 production-plant workers at a UK acrylamide production facility. The relationship between biomarker levels and environmental monitoring data (air levels and hand washes) was investigated. Good correlations were found between all of the biomarkers (r(2)=0.86-0.91) and moderate correlations were found between the biomarkers and air levels (r(2) = 0.56-0.65). Our data show that urinary AAMA is a reliable biomarker of acrylamide exposure. Occupational hygiene data showed that acrylamide exposure at the company was well within the current UK Workplace Exposure Limit. The 90th percentile of urinary AAMA in non-smoking production-plant workers (537 μmol/mol creatinine (n = 59 samples)) is proposed as a possible biological monitoring guidance value. This 90th percentile increased to 798 μmol/mol if smokers were included (n = 72 samples). These values would be expected following an airborne exposure of less than 0.07 mg/m(3), well below the current UK workplace exposure limit of 0.3mg/m(3). Comparison of biomarker levels in non-occupationally exposed individuals suggests regional variations (between UK and Germany), possibly due to differences in diet. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Institutional investor monitoring motivation and the\\ud marginal value of cash

    OpenAIRE

    Zeng, Yeqin; Yin, Chao; Ward, Charles

    2018-01-01

    This paper examines whether the motivation of institutional investors in monitoring a firm is positively related to the relative importance of the firm's stock in their portfolios. We find that greater motivated monitoring institutional ownership is associated with a higher marginal value of corporate cash holdings, which cannot be explained by other corporate governance measures and institution types. Further, we find that the economic effect of institutional monitoring on the marginal value...

  4. FAIR VALUE MEASUREMENT UNDER IFRS 13

    Directory of Open Access Journals (Sweden)

    COZMA IGHIAN DIANA

    2015-07-01

    Full Text Available The IFRS 13, „Fair Value Measurement”, was first published in May 2011 and it applies to annual reporting periods that begin on or after January 1st 2013; this standard comes as a result of shared efforts on the part of the IASB and the FASB to develop a convergent framework regarding fair value measurement. The main purpose of this paper is to describe the main provisions of the IFRS 13 regarding fair value measurement, with a special emphasis on key concepts found throughout the standard, which refer to the principal market, the most advantageous market, the highest and best use, valuation techniques, and value hierarchy.

  5. Positive-Operator Valued Measure (POVM Quantization

    Directory of Open Access Journals (Sweden)

    Jean Pierre Gazeau

    2014-12-01

    Full Text Available We present a general formalism for giving a measure space paired with a separable Hilbert space a quantum version based on a normalized positive operator-valued measure. The latter are built from families of density operators labeled by points of the measure space. We especially focus on various probabilistic aspects of these constructions. Simple ormore elaborate examples illustrate the procedure: circle, two-sphere, plane and half-plane. Links with Positive-Operator Valued Measure (POVM quantum measurement and quantum statistical inference are sketched.

  6. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  7. Measuring values for cross-cultural research

    NARCIS (Netherlands)

    Maseland, R.K.J.; Hoorn, A.A.J. van

    2009-01-01

    This paper investigates the empirical relevance of the recent critique that values surveys, as they are, suffer from the problem of measuring marginal preferences rather than values. By surveying items from cross-cultural surveys by Hofstede, Inglehart and GLOBE, we show that the marginal

  8. Air Monitoring, Measuring, and Emissions Research

    Science.gov (United States)

    Measurement research is advancing the ability to determine the composition of sources of air pollution, conduct exposure assessments, improve monitoring capabilities and support public health research.

  9. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1996-01-01

    The guide presents the principles to be applied in calculating the equivalent dose and the effective dose, instructions on application of the maximum values for radiation exposure, and instruction on monitoring of radiation exposure. In addition, the measurable quantities to be used in monitoring the radiation exposure are presented. (2 refs.)

  10. Environmental performance, profitability, asset utilization, debt monitoring and firm value

    Science.gov (United States)

    Bukit, R. Br; Haryanto, B.; Ginting, P.

    2018-02-01

    The growing issue on firm value shows that firm value is not only determined by the firm ability to increase financial profit, but also by the company's concern in maintaining the environmental condition. The industrial development produces waste that pollutes the environment that has potential to serious impact on the next life. In addition to provide financial benefits, companies are increasingly facing pressure to be socially responsible for the survival of the company. However, past findings demonstrate that the effect of environmental performance, profitability, and asset utilization to the firm’s value are still unclear. This study aims to test whether environmental performance, firm profitability and asset utilization can effectively enhance firm value in two different conditions: intensive debt monitoring and less intensive debt monitoring. Sample of companies is taken from the list of Indonesia Stock Exchange during the period of 2013 to 2015. Using multiple regression analysis, discloses that: in intensive monitoring, managers tend to have high firm value when company has high environmental performance and or high profitability and high asset utilization. Monitoring system needs to be intensified especially for companies with the above characteristics.

  11. measurements of distribution coefficients and lipophilicity values

    African Journals Online (AJOL)

    Preferred Customer

    octanol and water, followed by measuring the distribution of the solute in ... Instrumentation and apparatus: HPLC-UV-DAD and HPLC–ESI-MS experiments .... process in the determination of KD and log P values for the HFSLM extracts. ..... Perrin, D.D.; Dempsey, B. Buffers for pH and Metal Ion Control, Chapman and Hall:.

  12. Lattice-Valued Possibilistic Entropy Measure

    Czech Academy of Sciences Publication Activity Database

    Kramosil, Ivan

    2008-01-01

    Roč. 16, č. 6 (2008), s. 829-846 ISSN 0218-4885 R&D Projects: GA AV ČR IAA100300503 Institutional research plan: CEZ:AV0Z10300504 Keywords : complete lattice * lattice-valued possibilistic distribution * entropy measure * product of possibilistic distribution Subject RIV: BA - General Mathematics Impact factor: 1.000, year: 2008

  13. Radioactivity monitoring network: Measurements 1987

    International Nuclear Information System (INIS)

    1989-01-01

    Four papers are presented: radionuclide concentration measurement in aerosols, surface water and the wastes of the Vienna Central Clarification Plant respectively, and on tritium in Austrian lakes and rivers. (qui)

  14. Shared Values?: Measuring Value Differences Between Civilians and Soldiers

    National Research Council Canada - National Science Library

    Efflandt, Scott

    1998-01-01

    .... In response to this many within and outside of the military have attributed these problems to the absence of personal values among new service members that are congruent with the military's core values...

  15. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can

  16. On the audit of fair value measurements

    Directory of Open Access Journals (Sweden)

    Jatinder P. Singh

    2015-04-01

    Full Text Available In this article, the hypotheses „whether the auditor’s functional domain, his approach, methodology and responsibilities are undergoing a metamorphosis with the adoption of Fair Value Accounting (hereinafter the „FVA” and whether his/her role is moving away from the mechanized attester of tangible evidence to the one exercising a substantively judgmental function in a holistic assessment of the values ascribed to be fair by the entity’s management” are tested. These hypotheses are tested on the basis of an analysis of the statutory provisions, the pronouncements of accounting and other regulatory bodies and accounting norms and theories. After setting forth the research objectives and the hypotheses, the necessity of the FVA is reviewed and the underlying philosophy is analyzed. Impediments in performing audits of fair-value-based measurements are then identified and the US auditing standards and their international counterparts are touched upon. Finally, some safeguards and precautions for the auditor in an audit of fair-value measurements are presented.

  17. Value measurement of nuclear medicine procedures

    International Nuclear Information System (INIS)

    Potchen, E.J.; Harris, G.I.; Schonbein, W.R.; Rashford, N.J.

    1977-01-01

    The difficulty in measuring the benefit component for cost/benefit analysis of diagnostic procedures in medicine is portrayed as a complex issue relating the objective of intent to a classification of types of decisions a physician must make in evaluating a patient's problem. Ultimately, it seems desirable to develop measuring instruments such as attitude measurement tools by which the relative value of alternative diagnostic procedures could be measured in terms of what they contribute to diminishing the patient's personal perception of disease. Even without this idealized objective, it is reasonable to assume that diagnostic tests which do not contain information, defined as a change in the randomness of a state of knowledge, could not be expected to ultimately benefit the patient. Thus diagnostic information should provide a rational direction for the physician to modify the course of the patient's illness. Since information can be measured as a change in randomness of a knowledge state, we can determine the information content of a specific nuclear medicine procedure when faced with an array of diagnostic problems. These measurements remain to be made for clinical nuclear medicine procedures and are currently under study

  18. Debate Regarding Measuring Accounting Value: Historical Cost against Fair Value

    OpenAIRE

    Victor Munteanu; Marilena Zuca

    2015-01-01

    The transition from historical cost to fair value represents an option with major implications in accounting, because it is a complex process that requires tuning to today’s trends of national and global economy. We can state that with all the advantages of using historical cost it has its limitations and it is” getting old”. That doesn’t mean that will be abandoned but substituted when it is needed with another value. At present, the lack of historical value is inconceivable; many practit...

  19. Debate Regarding Measuring Accounting Value: Historical Cost against Fair Value

    Directory of Open Access Journals (Sweden)

    Victor Munteanu

    2015-12-01

    Full Text Available The transition from historical cost to fair value represents an option with major implications in accounting, because it is a complex process that requires tuning to today’s trends of national and global economy. We can state that with all the advantages of using historical cost it has its limitations and it is” getting old”. That doesn’t mean that will be abandoned but substituted when it is needed with another value. At present, the lack of historical value is inconceivable; many practitioners consider it to be the best method to evaluate assets.

  20. VALUE AT RISK - CORPORATE RISK MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Anis Cecilia-Nicoleta

    2011-12-01

    Full Text Available The notion of 'risk' is used in a number of sciences. The Faculty of Law studies the risk depending on its legality. The Accident Theory applies this term to describe the damage and the disasters. One can find studies on the risks in the works of psychology, philosophy, medicine and within each of these areas the study of the risk is based on the given science subject and, of course, on their methods and approaches. Such a variety of risk study is explained by the diversity of this phenomenon. Under the market economy conditions, the risk is an essential component of any economic agent management policy, of the approach developed by this one, a strategy that depends almost entirely on individual ability and capacity to anticipate his evolution and to exploit his opportunities, assuming a so-called 'risk of business failure.' There are several ways to measure the risks in projects, one of the most used methods to measure this being the Value at Risk(VaR. Value at Risk (VaR was made famous by JP Morgan in the mid 1990s, by introducing the RiskMetrics approach, and hence, by far, has been sanctioned by several Governing Bodies throughout the world bank. In short, it measures the value of risk capital stocks in a given period at a certain probability of loss. This measurement can be modified for risk applications through, for example, the potential loss values affirmation in a certain amount of time during the economic life of the project- clearly, a project with a lower VaR is better. It should be noted that it is not always possible or advisable for a company to limit itself to the remote analysis of each risk because the risks and their effects are interdependent and constitute a system .In addition, there are risks which, in combination with other risks, tend to produce effects which they would not have caused by themselves and risks that tend to offset and even cancel each other out.

  1. Quantum measurement with a positive operator-valued measure

    International Nuclear Information System (INIS)

    Brandt, Howard E

    2003-01-01

    In the quantum theory of measurement, the positive operator-valued measure (POVM) is an important concept, and its implementation can be useful. A POVM consists of a set of non-negative quantum-mechanical Hermitian operators that add up to the identity. The probability that a quantum system is in a particular state is given by the expectation value of the POVM operator corresponding to that state. Following a brief review of the mathematics and mention of the history of POVMs in quantum theory, a particular implementation of a POVM for use in the measurement of nonorthogonal photon polarization states is reviewed. The implementation consists simply of a Wollaston prism, a mirror, two beam splitters, a polarization rotator and three phototubes arranged in an interferometric configuration, and it is shown analytically that the device faithfully represents the POVM. Based on Neumark's extension theorem, the two-dimensional Hilbert space of the POVM implementation can be embedded in the three-dimensional Hilbert space of an ordinary projective-valued measure. Also, analytical expressions are given for the maximum Renyi information loss from the device to a disturbing probe, and for the error and inconclusive rates induced by the probe. Various aspects of the problem of probe optimization are elaborated

  2. Weak-value measurements can outperform conventional measurements

    International Nuclear Information System (INIS)

    Magaña-Loaiza, Omar S; Boyd, Robert W; Harris, Jérémie; Lundeen, Jeff S

    2017-01-01

    In this paper we provide a simple, straightforward example of a specific situation in which weak-value amplification (WVA) clearly outperforms conventional measurement in determining the angular orientation of an optical component. We also offer a perspective reconciling the views of some theorists, who claim WVA to be inherently sub-optimal for parameter estimation, with the perspective of the many experimentalists and theorists who have used the procedure to successfully access otherwise elusive phenomena. (invited comment)

  3. Continuous pneumothorax monitoring by remittance measurement

    NARCIS (Netherlands)

    Beek, J. F.; Sterenborg, H. J.; van Gemert, M. J.

    1993-01-01

    The feasibility of a noninvasive method, based on a remittance measurement, to monitor continuously for the occurrence of pneumothorax in neonates under ventilation, was investigated through animal experiments. Light from a He-Ne laser (632.8 nm) or a semiconductor laser (790 nm) was incident on the

  4. Measurement of Detector Efficiency for the CZT Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Kang Hwa; Kon, Kang Seo; Kim, Jeongin [KHNP, Radiation Health Research Institute, Seoul (Korea, Republic of)

    2014-05-15

    Evaluation method of using CZT have been being attempted in various places such as AEP(American Electronic Power) etc since EDF(Electricite de France) had apply to the project named 'Source Term Reduction'. CZT can measure source terms on various places in nuclear power plants because it is available at room temperature unless a seperate device and portability is good. Consequently, CZT show good result from analysis of source terms in nuclear power plants. This study found out efficiency of CZT detector that is now researched in CZT Monitoring System for measure source terms on RCS system of domestic old and new nuclear power plants and verified measured efficiency values by comparing to reference efficiency we already know. This study was carried out for finding out detector's efficiency depending on necessary energy in order to save quantitative radioactivity value of source terms. Eventually, this study is to develope CZT Monitoring System measuring CRUD in domestic PWRs primary system or piping system by carrying out in-vivo. Considering error ratio ±20% on radioactivity value of CRM used in measuring and verifying efficiency, measurement of detector Efficiency for the CZT Monitoring System is good. But more various tests is needed than now for an accurate measurement.

  5. Comparison of the values of measured hydratation of sporting youths with normative values

    Directory of Open Access Journals (Sweden)

    Petr Kutáč

    2013-06-01

    Full Text Available BACKROUND: When measuring body composition, we monitor the fractionalization of body weight and the share of the individual elements in its aggregate value. The total body water (TBW is a very important element in addition to the share of body fat (BF, muscle mass and bone minerals. Water is the largest element of the body weight and its sufficient amount (organism hydration is a condition for maintaining the physiological functions of the person and thus has an immediate effect on the health of the individual. OBJECTIVE: The aim of the study is to check the standard values of the percentage share of the representation of the total body water in the total body weight in different age groups of sporting youths using the tetrapolar bio-impedance Tanita 418 MA scale. METHODS: The research group included a total of 532 individuals (332 men and 200 women at the age from 12 to 17 years. They were individuals with regular physical activity and without any health problems. The measurement was carried out using the tetrapolar bio-impedance TANITA 418 MA scale. The confidence interval at the reliability level of .99 was used to define the range of the standard values of the percentage share of the total body water representation. The normalization index Ni was used to compare the mean values of the total body water representation with the reference file. RESULTS: The mean values of the TBW representation in boys ranged from 61.75 to 64.34% and in girls from 55.51 to 58.69%, always in relation to the age. The value of the upper bound of (95% the confidence interval of the Tanita 418 MA device software did not exceed the lower bound of the standard (65% in any of the monitored files. CONCLUSIONS: The results showed significant gender differences in the total body water representation that, however, the standard of the used device does not respect. The standard values are set high which was also confirmed by the comparison of our results with other studies

  6. Measurement of liquid radioactive materials for monitoring radioactive emissions

    International Nuclear Information System (INIS)

    1977-10-01

    This draft regulation applies to measuring equipment for liquid radioactive materials for the monitoring of the radioactive discharges from stationary nuclear power plants with LWR and HTR reactors. Demands made on the measuring procedure, methods of concentration determination, balancing, indication of limiting values, and inspections are layed down. The draft regulation deals with: 1) Monitoring liquid radioactive discharges: Water and similar systems; radionuclides and their detection limits, radioactively contaminated water (waste water); secondary cooling water; power house cooling water; primary cooling water; flooding water; 2) Layout of the measuring and sampling equipment and demands made on continuous and discontinuous measuring equipment; demands made on discontinuous α and β measuring equipment; 3) Maintenance and repair work; inspections; repair of defects; 4) Demands made on documentation; reports to authorities; 5) Supplement: List of general and reference regulations. (orig./HP) [de

  7. Measurement and estimation of dew point for SNG. [Comparison of calculated and measured values

    Energy Technology Data Exchange (ETDEWEB)

    Furuyama, Y.

    1974-08-01

    Toho Gas measured and estimated SNG dew points in high-pressure deliveries by calculating the theoretical values by the high-pressure gas-liquid equilibrium theory using the pressure-extrapolation method to reach K = 1, and the BWR method to estimate fugacity, then verifying these values experimentally. The experimental values were measured at 161.7 to 367.5 psi using the conventional static and circulation methods, in addition to a newly developed method consisting of circulating a known composition of gas mixtures, partially freezing them, and monitoring the dew point by observing the droplets on a mirror cooled by blowing liquid nitrogen. Good agreement was found between the calculated and the experimental values.

  8. Application of real time spectrum measurement to radiation monitors

    International Nuclear Information System (INIS)

    Matsuno, K.; Watanabe, M.; Sakamaki, T.

    1996-01-01

    A multichannel analyzer (MCA) and two realtime spectrum monitoring methods have been developed for use in radiation monitors. The new MCA was designed to be installed at a local site as a component of a radiation monitor. The MCA repeats spectrum measurement at short intervals (Δt) and, after each measurement, transmits a spectrum datum to the operation console. The authors applied two methods to process Δt spectrum counts for each channel for longer time interval. One method of processing counts is the 'running average (RA) method'. The other method is the 'exponential smoothing (ES) method', which simulates RC rate meters by subtracting a fraction corresponding to the accumulated counts. Relative standard deviations for each channel can be made the same by selecting an appropriate value. The response with the 'ES' method is initially faster than that with the 'RA' method, but the 'RA' method allows a full response to be reached at a predictable time. (author)

  9. Mechanical seal monitoring technique by acoustic emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tadashi; Fujita, Yoshihiro; Kawaguchi, Kazunori; Saito, Kazuhiro; Yokota, Setsuo; Hisada, Yasuhide; Masahiro, Komatsu

    1987-09-20

    This report describes a technique for mechanical seal monitoring through acoustic emission (AE) measurement. The equipment consists of an AE sensor, preamplifier, multiplexer, main amplifier, effective value transducer and computer system. When the sealed liquid pressure undergoes a large change, the seal surface configuration is monitored and evaluated accurately through AE measurement. If the mechanical seal surface id damaged or worn, the AE level is kept high or continues to fluctuate largely for a rather long period. When leak occurs, the AE value shows great fluctuations either at extremely low levels or at high levels. The former trend is considered to result from a decrease in solid contact due to an excessive amount of liquid film being formed at the seal surface during leak. In the latter case, the leak is attributed to severe damage to the seal surface. (18 figs, 1 tab, 5 photos, 3 refs)

  10. Cultural Value, Measurement and Policy Making

    Science.gov (United States)

    O'Brien, Dave

    2015-01-01

    No matter what the national context, the question of how to understand the impact of government programmes, particularly in terms of value for money, has emerged as a complex problem to be solved by social scientific management. This article engages with these trends in two ways. It focuses on the UK to understand how these tools and technologies…

  11. Measuring the safeguards value of material accountability

    International Nuclear Information System (INIS)

    Sicherman, A.

    1988-01-01

    Material accountability (MA) activities focus on providing after-the-fact indication of diversion or theft of special nuclear material (SNM). MA activities include maintaining records for tracking nuclear material and conducting periodic inventories and audits to ensure that loss has not occurred. This paper presents a value model concept for assessing the safeguards benefits of MA activities and for comparing these benefits to those provided by physical protection (PP) and material control (MC) components. The model considers various benefits of MA, which include: 1) providing information to assist in recovery of missing material, 2) providing assurance that physical protection and material control systems have been working, 3) defeating protracted theft attempts, and 4) properly resolving causes of and responding appropriately to anomalies of missing material and external alarms (e.g., hoax). Such a value model can aid decision-makers in allocating safeguards resources among PP, MC, and MA systems

  12. Stride length: measuring its instantaneous value

    International Nuclear Information System (INIS)

    Campiglio, G C; Mazzeo, J R

    2007-01-01

    Human gait has been studied from different viewpoints: kinematics, dynamics, sensibility and others. Many of its characteristics still remain open to research, both for normal gait and for pathological gait. Objective measures of some of its most significant spatial/temporal parameters are important in this context. Stride length, one of these parameters, is defined as the distance between two consecutive contacts of one foot with ground. On this work we present a device designed to provide automatic measures of stride length. Its features make it particularly appropriate for the evaluation of pathological gait

  13. Exemption values and measurements in international comparison

    International Nuclear Information System (INIS)

    Neider, R.

    1994-01-01

    Activities are developed worldwide to systematically derive exemption limits or exemption values (IAEA, ICRP, Radiation Protection Ordinance) for different applications according to uniform principles. An important step in this regard is the adoption of the new guideline of the EU Council on radiation protection. Also regarding a uniform definition of the exemption of material from nuclear installations, agreement should be reached soon in Europe. Due to different concepts of ultimate disposal of radioactive wastes, in particular low level wastes, internationally there is no prospect of a uniform regulation concerning the exemption of very low level wastes, while in Germany a corresponding recommendation has already been made by the radiation protection commission. The exemption limits valid at present are mentioned. (orig./HP) [de

  14. Simplified correction of g-value measurements

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    been carried out using a detailed physical model based on ISO9050 and prEN410 but using polarized data for non-normal incidence. This model is only valid for plane, clear glazings and therefor not suited for corrections of measurements performed on complex glazings. To investigate a more general...... correction procedure the results from the measurements on the Interpane DGU have been corrected using the principle outlined in (Rosenfeld, 1996). This correction procedure is more general as corrections can be carried out without a correct physical model of the investigated glazing. On the other hand...... the way this “general” correction procedure is used is not always in accordance to the physical conditions....

  15. Valuing compassion through definition and measurement.

    Science.gov (United States)

    Dewar, Belinda; Pullin, Simon; Tocheris, Ria

    2011-02-01

    The Leadership in Compassionate Care programme aims to embed compassionate care in practice and education. This article describes a project within the programme that explores with staff, patients and families the meaning of compassion and how this can be measured. The project has involved developing practice statements from noticing the aspects of compassionate care that work well. Staff were provided with support to consider, develop and implement actions that would help ensure consistency in developing compassionate care.

  16. Measuring oxidation processes: Atomic oxygen flux monitor

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Of the existing 95 high-energy accelerators in the world, the Stanford Linear Collider (SLC) at the Stanford Linear Accelerator Center (SLAC) is the only one of the linear-collider type, where electrons and positrons are smashed together at energies of 50 GeV using linear beams instead of beam rings for achieving interactions. Use of a collider eliminates energy losses in the form of x-rays due to the curved trajectory of the rings, a phenomena known as bremsstrauhlung. Because these losses are eliminated, higher interaction energies are reached. Consequently the SLC produced the first Z particle in quantities large enough to allow measurement of its physical properties with some accuracy. SLAC intends to probe still deeper into the structure of matter by next polarizing the electrons in the beam. The surface of the source for these polarized particles, typically gallium arsenide, must be kept clean of contaminants. One method for accomplishing this task requires the oxidation of the surface, from which the oxidized contaminants are later boiled off. The technique requires careful measurement of the oxidation process. SLAC researchers have developed a technique for measuring the atomic oxygen flux in this process. The method uses a silver film on a quartz-crystal, deposition-rate monitor. Measuring the initial oxidation rate of the silver, which is proportional to the atomic oxygen flux, determines a lower limit on that flux in the range of 10 13 to 10 17 atoms per square centimeter per second. Furthermore, the deposition is reversible by exposing the sensor to atomic hydrogen. This technique has wider applications to processes in solid-state and surface physics as well as surface chemistry. In semiconductor manufacturing where a precise thickness of oxide must be deposited, this technique could be used to monitor the critical flux of atomic oxygen in the process

  17. Automatic solar image motion measurements. [electronic disk flux monitoring

    Science.gov (United States)

    Colgate, S. A.; Moore, E. P.

    1975-01-01

    The solar seeing image motion has been monitored electronically and absolutely with a 25 cm telescope at three sites along the ridge at the southern end of the Magdalena Mountains west of Socorro, New Mexico. The uncorrelated component of the variations of the optical flux from two points at opposite limbs of the solar disk was continually monitored in 3 frequencies centered at 0.3, 3 and 30 Hz. The frequency band of maximum signal centered at 3 Hz showed the average absolute value of image motion to be somewhat less than 2sec. The observer estimates of combined blurring and image motion were well correlated with electronically measured image motion, but the observer estimates gave a factor 2 larger value.

  18. Real-time database for high resolution neutron monitor measurements

    Energy Technology Data Exchange (ETDEWEB)

    Steigies, Christian T.; Rother, Oliver M.; Wimmer-Schweingruber, Robert F.; Heber, Bernd [IEAP, Christian-Albrechts-Universitaet zu Kiel (Germany)

    2008-07-01

    The worldwide network of standardised neutron monitors is, after 50 years, still the state-of-the-art instrumentation to measure spectral variations of the primary cosmic ray component. These measurements are an ideal complement to space based cosmic ray measurements. Data from the approximately 50 IGY and NM64 neutron monitors is stored locally but also available through data collections sites like the World Data Center (WDC) or the IZMIRAN ftp server. The data from the WDC is in a standard format, but only hourly values are available. IZMIRAN collects the data in the best available time resolution, but the data arrives on the ftp server only hours, sometimes days, after the measurements. Also, the high time-resolution measurements of the different stations do not have a common format, a conversion routine for each station is needed before they can be used for scientific analysis. Supported by the 7th framework program of the European Commission, we are setting up a real-time database where high resolution cosmic ray measurements will be stored and accessible immediately after the measurement. Stations that do not have 1-minute resolution measurements will be upgraded to 1-minute or better resolution with an affordable standard registration system, that will submit the measurements to the database via the internet in real-time.

  19. Opinion Paper: 'Likelihood-ratio' and 'odds' applied to monitoring of patients as a supplement to 'reference change value' (RCV)

    DEFF Research Database (Denmark)

    Petersen, Per Hyltoft; Sandberg, Sverre; Iglesias, Natàlia

    2007-01-01

    and odds used for diagnostic test evaluations is applied to monitoring by substituting measured concentrations with measured differences. Thus, two frequency distributions of differences are assumed, one for a stable, steady-state, situation and one for a certain change. Values exceeding a measured...

  20. Ultrasonic flow measurements for irrigation process monitoring

    Science.gov (United States)

    Ziani, Elmostafa; Bennouna, Mustapha; Boissier, Raymond

    2004-02-01

    This paper presents the state of the art of the general principle of liquid flow measurements by ultrasonic method, and problems of flow measurements. We present an ultrasonic flowmeter designed according to smart sensors concept, for the measurement of irrigation water flowing through pipelines or open channels, using the ultrasonic transit time approach. The new flowmeter works on the principle of measuring time delay differences between sound pulses transmitted upstream and downstream in the flowing liquid. The speed of sound in the flowing medium is eliminated as a variable because the flowrate calculations are based on the reciprocals of the transmission times. The transit time difference is digitally measured by means of a suitable, microprocessor controlled logic. This type of ultrasonic flowmeter will be widely used in industry and water management, it is well studied in this work, followed by some experimental results. For pressurized channels, we use one pair of ultrasonic transducer arranged in proper positions and directions of the pipe, in this case, to determine the liquid velocity, a real time on-line analysis taking account the geometries of the hydraulic system, is applied to the obtained ultrasonic data. In the open channels, we use a single or two pairs of ultrasonic emitter-receiver according to the desired performances. Finally, the goals of this work consist in integrating the smart sensor into irrigation systems monitoring in order to evaluate potential advantages and demonstrate their performance, on the other hand, to understand and use ultrasonic approach for determining flow characteristics and improving flow measurements by reducing errors caused by disturbances of the flow profiles.

  1. Religiosity and basic values of Russians (based on the European Social Survey and Orthodox Monitor

    Directory of Open Access Journals (Sweden)

    Elena Prutskova

    2017-12-01

    Full Text Available The article examines the relationship between religiosity and basic values in Russia. Basic values are measured by the Schwartz's Portrait Value Questionnaire. The analysis is based on the data of the European Social Survey conducted in 2012 and the Orthodox Monitor survey conducted in 2012 as well, which is a representative survey of churched Russian Orthodox Christians. Usually based on the results of mass surveys, the connection of basic values with religiosity in Russia is very weak. One possible reason is the use of inappopriate indicators to measure the degree of religiosity. One of the most important characteristics that distinguish churched Orthodox Christians is regular Communion, which presupposes quite serious preparation, fasting and Confession. People make an attempt to rethink their views, values, and change their behavior. If this happens with a certain regularity, then it can lead to a gradual change in basic values, conditioned by religiosity. Such working out the best of oneself may not occur if a person just attends religious services, but does not receive Communion. Churched Orthodox are much more committed to the values of Conservation and Self-Transcendence, and less to the values of Openness to change and Self-Enhancement. One of the unexpected results was the discovery of significant differences in the values of Universalism, in which the churched Orthodox Christians are noticeably ahead of the average Russians, while in most previous studies the relationship of religiosity to the values of Universalism was either negative or absent, and only rarely was weak positive. Also, despite the general low commitment to the values of Openness to change, the differences are due to the great rejection of the values of Hedonism and Stimulation, while the values of Self Direction differ from the average Russians only slightly.

  2. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    Science.gov (United States)

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  3. Assessing the value of information for long-term structural health monitoring

    Science.gov (United States)

    Pozzi, Matteo; Der Kiureghian, Armen

    2011-04-01

    In the field of Structural Health Monitoring, tests and sensing systems are intended as tools providing diagnoses, which allow the operator of the facility to develop an efficient maintenance plan or to require extraordinary measures on a structure. The effectiveness of these systems depends directly on their capability to guide towards the most optimal decision for the prevailing circumstances, avoiding mistakes and wastes of resources. Though this is well known, most studies only address the accuracy of the information gained from sensors without discussing economic criteria. Other studies evaluate these criteria separately, with only marginal or heuristic connection with the outcomes of the monitoring system. The concept of "Value of Information" (VoI) provides a rational basis to rank measuring systems according to a utility-based metric, which fully includes the decision-making process affected by the monitoring campaign. This framework allows, for example, an explicit assessment of the economical justifiability of adopting a sensor depending on its precision. In this paper we outline the framework for assessing the VoI, as applicable to the ranking of competitive measuring systems. We present the basic concepts involved, highlight issues related to monitoring of civil structures, address the problem of non-linearity of the cost-to-utility mapping, and introduce an approximate Monte Carlo approach suitable for the implementation of time-consuming predictive models.

  4. From Monitored Values to the Model Creation of the Dynamic System

    Directory of Open Access Journals (Sweden)

    Vladena BARANOVÁ

    2015-11-01

    Full Text Available Current information technology allow sensing and processes data recording under severe conditions of operation with new technical means in real time, storing the measurement data, its processing and evaluation in situ or in the laboratory. An example would be the monitoring system boring machine-rock used in tunneling Branisko. The monitored variables of the boring process were downforce of disconnecting head of boring machine, torque, speed of disconnecting head, the power consumption of the aggregate and the extended position of disconnecting head depending on the drilled length. These measured values allowed the creation of models, which help to modeling various properties of boring process within the meaning of Eykhoff definition: "A model is an expression of the essential characteristics of an existing object, which describes the knowledge of this object in a usable form".

  5. Historical Costs versus Fair Value Measurement in Financial Accounting

    OpenAIRE

    Dvořáková, Dana

    2009-01-01

    There are two important points in which in which we need assets and liabilities measured in financial accounting: on initial recognition and at a balance sheet day. Many International Financial Reporting Standards (IFRS) used the fair value measurement concept. But most of these standards use the fair value measurement method only at a balance sheet day. On initial recognition assets and liabilities are measured usually at costs. The IASB presented the discussion paper “Measurement Bases for ...

  6. Corporate performance and the measures of value added

    Directory of Open Access Journals (Sweden)

    T. Petravičius

    2008-09-01

    Full Text Available In recent years, managers have turned their attention to the ways increasing the value of their companies. A number of competing measures have been developed and marketed by investment and consulting firms. This paper considers the ways in which value can be created or destroyed in a firm and looks at how to calculate the cost of capital used to measure the opportunity cost of investing funds in one particular business instead of others with equivalent risk. Next, we have a look at the four most widely used value enhancement measures including Economic Value Added, Cash Flow Return on Investment, Market Value Added, Cash Value Added and use an example to think of where these approaches yield similar results and where differences might occur. In conclusion, we summarize the new or unique points in these competing measures, establish the information they can give and explain how to use it when managing and creating shareholder value.

  7. Reference values for generic instruments used in routine outcome monitoring: the leiden routine outcome monitoring study

    Directory of Open Access Journals (Sweden)

    Schulte-van Maaren Yvonne WM

    2012-11-01

    Full Text Available Abstract Introduction The Brief Symptom Inventory (BSI, Mood & Anxiety Symptom Questionnaire −30 (MASQ-D30, Short Form Health Survey 36 (SF-36, and Dimensional Assessment of Personality Pathology-Short Form (DAPP-SF are generic instruments that can be used in Routine Outcome Monitoring (ROM of patients with common mental disorders. We aimed to generate reference values usually encountered in 'healthy' and ‘psychiatrically ill’ populations to facilitate correct interpretation of ROM results. Methods We included the following specific reference populations: 1294 subjects from the general population (ROM reference group recruited through general practitioners, and 5269 psychiatric outpatients diagnosed with mood, anxiety, or somatoform (MAS disorders (ROM patient group. The outermost 5% of observations were used to define limits for one-sided reference intervals (95th percentiles for BSI, MASQ-D30 and DAPP-SF, and 5th percentiles for SF-36 subscales. Internal consistency and Receiver Operating Characteristics (ROC analyses were performed. Results Mean age for the ROM reference group was 40.3 years (SD=12.6 and 37.7 years (SD=12.0 for the ROM patient group. The proportion of females was 62.8% and 64.6%, respectively. The mean for cut-off values of healthy individuals was 0.82 for the BSI subscales, 23 for the three MASQ-D30 subscales, 45 for the SF-36 subscales, and 3.1 for the DAPP-SF subscales. Discriminative power of the BSI, MASQ-D30 and SF-36 was good, but it was poor for the DAPP-SF. For all instruments, the internal consistency of the subscales ranged from adequate to excellent. Discussion and conclusion Reference values for the clinical interpretation were provided for the BSI, MASQ-D30, SF-36, and DAPP-SF. Clinical information aided by ROM data may represent the best means to appraise the clinical state of psychiatric outpatients.

  8. 1991 measurement report. Air pollution monitoring in Schleswig-Holstein

    International Nuclear Information System (INIS)

    1992-01-01

    This article provides a report of the immission situation for 1991 in Schleswig-Holstein on the basis of the continuously processing measuring stations of the Air Hygienic Monitoring Schleswig-Holstein and the special measuring programs at selected sites. The measuring results of the Air Hygienic Monitoring determined for Schleswig-Holstein in 1991 can be summarized as follows: - The basic load of air by pollutants such as sulphur dioxide (SO 2 ), nitrogen monoxide (NO), nitrogen dioxide (NO 2 ) and airborne particles in relatively small in the entires region of the nation; Schleswig-Holstein is, therefore, continues to be ranked as one of the regions in the Federal Republic of Germany least burden to air contaminates. - A slight increase compared to the previous year could be determined for the components of sulphur dioxide and airborne particles. - The limit values defined by the European Community (EG) were adhered to at the time of the report; the admittance values for SO 2 and NO 2 were, however, exceeded. (orig./KW) [de

  9. Test method for measuring insulation values of cryogenic pipes

    NARCIS (Netherlands)

    Velthuis, J.F.M.; Blokland, H.; Klaver, B.W.; Beld, C. van de

    2010-01-01

    In this paper a large-area heat flux and temperature sensor (HFT) is used for the evaluation of the insulation value of cryogenic pipes. The HFT is flexible and clamp-on. The test method is relatively simple and can be used in-situ. The HFT makes it possible to monitor insulation performance over

  10. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    Directory of Open Access Journals (Sweden)

    V.V. Svitselska

    2015-03-01

    Full Text Available The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair value» is narrower and more accurate than the previous, it clarifies the subject matter, subjects of transactions, as well as the date of its execution. The scheme of estimation at fair value as well as model of fair value determination according to IFRS 13 «Fair Value Measurement» has been presented. Methods of measurement at fair value and the fair value hierarchy have been researched. Some disadvantages of provisions of IFRS 13 «Fair Value Measurement» on the basis of its analysis have been highlighted, uncertainty is essential among them in which fair value should be applied.

  11. Measurement of small dispersion values in optical components

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Liu, Fenghai; Pedersen, Rune Johan Skullerud

    1999-01-01

    It is reported that small dispersion values in optical components can be measured using the RF modulation method originally restricted to large dispersions. Using a constant dispersion offset, arbitrarily small dispersion values can be measured with a resolution as good as 1.2 ps/nm....

  12. Measurement Invariance of Expectancy-Value Questionnaire in Physical Education

    Science.gov (United States)

    Zhu, Xihe; Sun, Haichun; Chen, Ang; Ennis, Catherine

    2012-01-01

    Expectancy-Value Questionnaire (EVQ) measures student expectancy beliefs and task values of the domain content (Eccles & Wigfield, 1995). In this study the authors examine measurement invariance of EVQ in the domain of physical education between elementary and middle-school students. Participants included 811 students (3rd-5th grades) from 13…

  13. A method for valuing architecture-based business transformation and measuring the value of solutions architecture

    OpenAIRE

    Slot, R.G.

    2010-01-01

    Enterprise and Solution Architecture are key in today’s business environment. It is surprising that the foundation and business case for these activities are nonexistent; the financial value for the business of these activities is largely undetermined. To determine business value of enterprise and solution architecture, this thesis shows how to measure and quantify, in business terms, the value of enterprise architecture-based on business transformation and the value of solution architecture.

  14. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  15. Fair Value Accounting and Measurement through FASB’s Developments

    OpenAIRE

    Bonaci, Carmen Giorgiana; Strouhal, Jiří; Matis, Dumitru

    2009-01-01

    Our research follows the path of fair value as a term and concept, as well as its disclosure, measurement and recognition back from 1953 until our days, and analyzes the regulations issued by United States Accounting Standard setters, through the point of view of the historical events, which led to their appearance. Our study brings its’ contribution to complementing growing literature on the value relevance of fair value, but focuses on the assessment of fair value as a financial reporting s...

  16. Retrieval monitoring is influenced by information value: the interplay between importance and confidence on false memory.

    Science.gov (United States)

    McDonough, Ian M; Bui, Dung C; Friedman, Michael C; Castel, Alan D

    2015-10-01

    The perceived value of information can influence one's motivation to successfully remember that information. This study investigated how information value can affect memory search and evaluation processes (i.e., retrieval monitoring). In Experiment 1, participants studied unrelated words associated with low, medium, or high values. Subsequent memory tests required participants to selectively monitor retrieval for different values. False memory effects were smaller when searching memory for high-value than low-value words, suggesting that people more effectively monitored more important information. In Experiment 2, participants studied semantically-related words, and the need for retrieval monitoring was reduced at test by using inclusion instructions (i.e., endorsement of any word related to the studied words) compared with standard instructions. Inclusion instructions led to increases in false recognition for low-value, but not for high-value words, suggesting that under standard-instruction conditions retrieval monitoring was less likely to occur for important information. Experiment 3 showed that words retrieved with lower confidence were associated with more effective retrieval monitoring, suggesting that the quality of the retrieved memory influenced the degree and effectiveness of monitoring processes. Ironically, unless encouraged to do so, people were less likely to carefully monitor important information, even though people want to remember important memories most accurately. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Stability monitoring for BWR based on singular value decomposition method using artificial neural network

    International Nuclear Information System (INIS)

    Tsuji, Masashi; Shimazu, Yoichiro; Michishita, Hiroshi

    2005-01-01

    A new method for evaluating the decay ratios in a boiling water reactor (BWR) using the singular value decomposition (SVD) method had been proposed. In this method, a signal component closely related to the BWR stability can be extracted from independent components of the neutron noise signal decomposed by the SVD method. However, real-time stability monitoring by the SVD method requires an efficient procedure for screening such components. For efficient screening, an artificial neural network (ANN) with three layers was adopted. The trained ANN was actually applied to decomposed components of local power range monitor (LPRM) signals that were measured in stability experiments conducted in the Ringhals-1 BWR. In each LPRM signal, multiple candidates were screened from the decomposed components. However, decay ratios could be estimated by introducing appropriate criterions for selecting the most suitable component among the candidates. The estimated decay ratios are almost identical to those evaluated by visual screening in a previous study. The selected components commonly have the largest singular value, the largest decay ratio and the least squared fitting error among the candidates. By virtue of excellent screening performance of the trained ANN, the real-time stability monitoring by the SVD method can be applied in practice. (author)

  18. Passive in-home health and wellness monitoring: overview, value and examples.

    Science.gov (United States)

    Alwan, Majd

    2009-01-01

    Modern sensor and communication technology, coupled with advances in data analysis and artificial intelligence techniques, is causing a paradigm shift in remote management and monitoring of chronic disease. In-home monitoring technology brings the added benefit of measuring individualized health status and reporting it to the care provider and caregivers alike, allowing timely and targeted preventive interventions, even in home and community based settings. This paper presents a paradigm for geriatric care based on monitoring older adults passively in their own living settings through placing sensors in their living environments or the objects they use. Activity and physiological data can be analyzed, archived and mined to detect indicators of early disease onset or changes in health conditions at various levels. Examples of monitoring systems are discussed and results from field evaluation pilot studies are summarized. The approach has shown great promise for a significant value proposition to all the stakeholders involved in caring for older adults. The paradigm would allow care providers to extend their services into the communities they serve.

  19. THE ISSUES IN THE MEASUREMENT OF POSTMATERIAL VALUES

    Directory of Open Access Journals (Sweden)

    Svetlana Tasić

    2012-02-01

    Full Text Available The measurement of postmaterial values includes measuring of the views on the preservation ofpeace, freedom of speech, environmental protection, tolerance and everything else that is contrary tothe concept of measuring the material values, that is physical and economic variables. Measurementof postmaterial values is based on the application of 4 or 12 items scale that refers to the materialismor postmaterialism in certain country. There are several issues and limitations in the application ofpostmaterial values measurement scale which can cause significant error, in other words bias inmeasurement. One of the most interesting issues is the impact of question order change on themeasurement results of postmaterial values. Using the results of empirical research it is shown thatthis effect is significant and, also it is particularly examined the intensity of this effect consideringgender and level of education based on the sample of respondents from urban Serbia.

  20. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  1. The value of intra-abdominal pressure monitoring through ...

    African Journals Online (AJOL)

    hypertension after abdominal closure (8%) and only one of ... Ann Pediatr. Surg 13:69–73 c 2017 Annals of Pediatric Surgery. Annals of ... intra-abdominal hypertension ..... measurements as a guide in the closure of abdominal wall defects.

  2. U-value measurements on a roof window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    This report describes the results of the U-value measurements performed on a roof window. The work is as a part of the development of an ISO/CEN standard measuring procedure for roof windows.The measurements have been performed using the procedures given in ISO 12567 draft version 1998...

  3. The value of citizen science for ecological monitoring of mammals

    Directory of Open Access Journals (Sweden)

    Arielle Waldstein Parsons

    2018-03-01

    Full Text Available Citizen science approaches are of great interest for their potential to efficiently and sustainably monitor wildlife populations on both public and private lands. Here we present two studies that worked with volunteers to set camera traps for ecological surveys. The photographs recorded by these citizen scientists were archived and verified using the eMammal software platform, providing a professional grade, vouchered database of biodiversity records. Motivated by managers’ concern with perceived high bear activity, our first example enlisted the help of homeowners in a short-term study to compare black bear activity inside a National Historic Site with surrounding private land. We found similar levels of bear activity inside and outside the NHS, and regional comparisons suggest the bear population is typical. Participants benefited from knowing their local bear population was normal and managers refocused bear management given this new information. Our second example is a continuous survey of wildlife using the grounds of a nature education center that actively manages habitat to maintain a grassland prairie. Center staff incorporated the camera traps into educational programs, involving visitors with camera setup and picture review. Over two years and 5,968 camera-nights this survey has collected 41,393 detections of 14 wildlife species. Detection rates and occupancy were higher in open habitats compared to forest, suggesting that the maintenance of prairie habitat is beneficial to some species. Over 500 volunteers of all ages participated in this project over two years. Some of the greatest benefits have been to high school students, exemplified by a student with autism who increased his communication and comfort level with others through field work with the cameras. These examples show how, with the right tools, training and survey design protocols, citizen science can be used to answer a variety of applied management questions while

  4. The use of personal values in living standards measures

    African Journals Online (AJOL)

    2011-08-26

    Aug 26, 2011 ... Values Questionnaire, Living Standards Measure, purchase decision- .... According to Schwartz (1992), scholars in the areas of psychology, anthropology ... The application of the values perspective to the marketing of .... is a fairly complex task involving large data tables, and that some of the LSM groups.

  5. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  6. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    OpenAIRE

    V.V. Svitselska

    2015-01-01

    The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair v...

  7. Adam Smith's Concept of Labour: Value or Measure?

    OpenAIRE

    Adolfo Rodriguez-Herrera

    2014-01-01

    The terminology employed by Smith to refer to value and measure of value is used in his time with imprecision, which has led to different interpretations about his position on these issues. It is no coincidence that Smith is considered the father of the labour theory of value developed by David Ricardo and Karl Marx and simultaneously of the cost-of-production theory of value developed by John Stuart Mill and Alfred Marshall. This paper reviews the concepts developed by Smith to formulate his...

  8. Effectiveness Monitoring Report, MWMF Tritium Phytoremediation Interim Measures.

    Energy Technology Data Exchange (ETDEWEB)

    Hitchcock, Dan; Blake, John, I.

    2003-02-10

    This report describes and presents the results of monitoring activities during irrigation operations for the calendar year 2001 of the MWMF Interim Measures Tritium Phytoremediation Project. The purpose of this effectiveness monitoring report is to provide the information on instrument performance, analysis of CY2001 measurements, and critical relationships needed to manage irrigation operations, estimate efficiency and validate the water and tritium balance model.

  9. The Influence of Brittle Daniels System Characteristics on the Value of Load Monitoring Information

    DEFF Research Database (Denmark)

    Thöns, Sebastian; Schneider, Ronald

    This paper addresses the influence of deteriorating brittle Daniels system characteristics on the value of structural health monitoring (SHM). The value of SHM is quantified as the difference between the life cycle benefits with and without SHM. A value of SHM analysis is performed within...

  10. Value for money: Defining and measuring 'value' in MoD's acquisition policy of obtaining best value for money

    OpenAIRE

    Weiss, A.

    2006-01-01

    Obtaining value for money is a keystone of UK Ministry of Defence (MoD) acquisition strategy embedded in its Smart Acquisition policy. This thesis examines how best to measure the relative value of competing tender submissions for major projects. There is a comprehensive discussion of a wide range of relevant definitions and over three dozen documents are scrutinised including just some sixteen published by the Government. Commercially available models, algorithms and software are examined as...

  11. Theory of “Weak Value" and Quantum Mechanical Measurements

    OpenAIRE

    Shikano, Yutaka

    2012-01-01

    Comment: to be published from "Measurements in Quantum Mechanics", edited by M. R. Pahlavani (InTech, 2012) Chapter 4 page 75. Yutaka Shikano (2012). ISBN: 978-953-51-0058-4 Available from: http://www.intechopen.com/articles/show/title/theory-of-weak-value-and-quantum-mechanical-measurement

  12. The use of personal values in living standards measures | Ungerer ...

    African Journals Online (AJOL)

    The Living Standards Measure (LSM), a South African marketing segmentation method, is a multivariate wealth measure based on standard of living. This article reports on whether a rationale can be found for the inclusion of psychological variables, particularly personal values, in this type of multivariate segmentation.

  13. Evaluation of consumer monitors to measure particulate matter.

    Science.gov (United States)

    Sousan, Sinan; Koehler, Kirsten; Hallett, Laura; Peters, Thomas M

    2017-05-01

    Recently, inexpensive (consumer aerosol monitors (CAMs) targeted for use in homes have become available. We evaluated the accuracy, bias, and precision of three CAMs (Foobot from Airoxlab, Speck from Carnegie Mellon University, and AirBeam from HabitatMap) for measuring mass concentrations in occupational settings. In a laboratory study, PM 2.5 measured with the CAMs and a medium-cost aerosol photometer (personal DataRAM 1500, Thermo Scientific) were compared to that from reference instruments for three aerosols (salt, welding fume, and Arizona road dust, ARD) at concentrations up to 8500 μg/m 3 . Three of each type of CAM were included to estimate precision. Compared to reference instruments, mass concentrations measured with the Foobot (r-value = 0.99) and medium-cost photometer (r-value = 0.99) show strong correlation, whereas those from the Speck (r-value range 0.88 - 0.99) and AirBeam (0.7 - 0.96) were less correlated. The Foobot bias was (-12%) for ARD and measurements were similar to the medium-cost instrument. Foobot bias was (< -46%) for salt and welding fume aerosols. Speck bias was at 18% salt for ARD and -86% for welding fume. AirBeam bias was (-36%) for salt and (-83%) for welding fume. All three photometers had a bias (< -82%) for welding fume. Precision was excellent for the Foobot (coefficient of variation range: 5% to 8%) and AirBeam (2% to 9%), but poorer for the Speck (8% to 25%). These findings suggest that the Foobot, with a linear response to different aerosol types and good precision, can provide reasonable estimates of PM 2.5 in the workplace after site-specific calibration to account for particle size and composition.

  14. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  15. A Framework for Measuring Low-Value Care.

    Science.gov (United States)

    Miller, George; Rhyan, Corwin; Beaudin-Seiler, Beth; Hughes-Cromwick, Paul

    2018-04-01

    It has been estimated that more than 30% of health care spending in the United States is wasteful, and that low-value care, which drives up costs unnecessarily while increasing patient risk, is a significant component of wasteful spending. To address the need for an ability to measure the magnitude of low-value care nationwide, identify the clinical services that are the greatest contributors to waste, and track progress toward eliminating low-value use of these services. Such an ability could provide valuable input to the efforts of policymakers and health systems to improve efficiency. We reviewed existing methods that could contribute to measuring low-value care and developed an integrated framework that combines multiple methods to comprehensively estimate and track the magnitude and principal sources of clinical waste. We also identified a process and needed research for implementing the framework. A comprehensive methodology for measuring and tracking low-value care in the United States would provide an important contribution toward reducing waste. Implementation of the framework described in this article appears feasible, and the proposed research program will allow moving incrementally toward full implementation while providing a near-term capability for measuring low-value care that can be enhanced over time. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  16. Determination of contamination operational value by routine monitoring in research laboratories

    International Nuclear Information System (INIS)

    Salomao, Edeilson; Medeiros, Regina Bitelli; Mattos, Maria Fernanda S.S.; Daros, Kellen Adriana Curci

    2008-01-01

    The radioisotopes have a large spectrum of applicability in many areas of science, as in medicine, agriculture and industry in general. In the biological area, the radioisotopes have brought many benefits to study physiological processes in living organisms and in vitro. The most radioisotopes used in biological research are emitters of radiation of low energy, mainly β, and are used as unsealed sources. The manipulation of these radioisotopes generates radioactive wastes and eventually can cause contamination in the areas of handling or even occasionally in areas to which access is not controlled. According to CNEN-NE-3.02 standard is necessary and mandatory the exposure and contamination levels control in the areas of handling of unsealed sources. The goal of the work is to establish how often the monitoring should be done through the survey of the contamination and exposure levels, in areas designed to manipulate 32 P and how this monitoring can contribute to the improvement the conditions of radiological protection. From the twenty eight research laboratories registered by 'Nucleo de Protecao Radiologica' (NPR) were selected four where the activities are not restrict to 32 P biological assays. The levels of contamination and exposure were evaluated using monitors GM and the layout of laboratories containing the points to be tracker defined based on the researchers' routine. At each point three values were obtained to measure the rate of contamination on the surface and exposure rate. The measures were made twice a week before and after the radioisotope manipulation. Based on these data was possible to establish the range from 0,306 to 0,678 Bq.cm -2 as operational average level to the superficial contamination. The average exposure rate measured was 5.16 n C/Kg.h. The results were important to demonstrating to researchers how they can contribute to the improvement of radiological protection conditions. (author)

  17. Uncertain added value of Global Trigger Tool for monitoring of patient safety in cancer care

    DEFF Research Database (Denmark)

    Lipczak, Henriette; Neckelmann, Kirsten; Steding-Jessen, Marianne

    2011-01-01

    Monitoring patient safety is a challenging task. The lack of a golden standard has contributed to the recommendation and introduction of several methods. In 2000 the Danish Lung Cancer Registry (DLCR) was established to monitor the clinical management of lung cancer. In 2008 the Global Trigger Tool...... (GTT) was recommended in Denmark as a tool for the monitoring of patient safety. Ideally, the recommendation of a new tool should be preceded by a critical assessment of its added value....

  18. [Implicit value judgments in the measurement of health inequalities].

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; E Reichman, Marsha; Breen, Nancy; Lynch, John

    2014-04-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data,we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  19. Implicit value judgments in the measurement of health inequalities.

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; Reichman, Marsha E; Breen, Nancy; Lynch, John

    2010-03-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data, we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  20. English Value-Added Measures: Examining the Limitations of School Performance Measurement

    Science.gov (United States)

    Perry, Thomas

    2016-01-01

    Value-added "Progress" measures are to be introduced for all English schools in 2016 as "headline" measures of school performance. This move comes despite research highlighting high levels of instability in value-added measures and concerns about the omission of contextual variables in the planned measure. This article studies…

  1. A model for measuring value for money in professional sports

    Directory of Open Access Journals (Sweden)

    Vlad ROŞCA

    2013-07-01

    Full Text Available Few to almost none sports teams measure the entertainment value they provide to fans in exchange of the money the latter ones spend on admission fees. Scientific literature oversees the issue as well. The aim of this paper is to present a model that can be used for calculating value for money in the context of spectating sports. The research question asks how can value for money be conceptualized and measured for sports marketing purposes? Using financial and sporting variables, the method calculates how much money, on average, a fan had to spend for receiving quality entertainment – defined as won matches – from his favorite team, during the last season of the Romanian first division football championship. The results only partially confirm the research hypothesis, showing that not just price and sporting performances may influence the value delivered to fans, but other factors as well.

  2. Measuring Values in Environmental Research: A Test of an Environmental Portrait Value Questionnaire

    Science.gov (United States)

    Bouman, Thijs; Steg, Linda; Kiers, Henk A. L.

    2018-01-01

    Four human values are considered to underlie individuals’ environmental beliefs and behaviors: biospheric (i.e., concern for environment), altruistic (i.e., concern for others), egoistic (i.e., concern for personal resources) and hedonic values (i.e., concern for pleasure and comfort). These values are typically measured with an adapted and shortened version of the Schwartz Value Survey (SVS), to which we refer as the Environmental-SVS (E-SVS). Despite being well-validated, recent research has indicated some concerns about the SVS methodology (e.g., comprehensibility, self-presentation biases) and suggested an alternative method of measuring human values: The Portrait Value Questionnaire (PVQ). However, the PVQ has not yet been adapted and applied to measure values most relevant to understand environmental beliefs and behaviors. Therefore, we tested the Environmental-PVQ (E-PVQ) – a PVQ variant of E-SVS –and compared it with the E-SVS in two studies. Our findings provide strong support for the validity and reliability of both the E-SVS and E-PVQ. In addition, we find that respondents slightly preferred the E-PVQ over the E-SVS (Study 1). In general, both scales correlate similarly to environmental self-identity (Study 1), energy behaviors (Studies 1 and 2), pro-environmental personal norms, climate change beliefs and policy support (Study 2). Accordingly, both methodologies show highly similar results and seem well-suited for measuring human values underlying environmental behaviors and beliefs. PMID:29743874

  3. A Single Bremsstrahlung Monitor to Measure Luminosity at LEP

    CERN Multimedia

    2002-01-01

    The luminosity, the beam divergence and the longitudinal polarization can be measured at an interaction point of LEP by dectecting the energy, the angular distribution and the circular polarization of the single bremsstrahlung photons (SB) emitted at very forward angle. The luminosity can be measured by this met than by the conventional method of detecting small angle Bhabha scattering. The bunch to bunch relative luminosity can be monitored at a few per mil level in few minutes. Absolute values of the luminosity and of the polarization can be measured with a precision of the order of 1\\%. \\\\ \\\\ The apparatus to detect SB photons consists of a low Z absorber and of an EM calorimeter made of lead and scintillating fibres. Both the total energy and the space distribution of the SB photons are measured. This apparatus has been designed and built at the Department of Physics and INFN Section of the University of Rome ``La Sapienza''. Later on, together with suitable monocrystal converters, it may be used also for...

  4. FAIR VALUE MEASUREMENT IN AGRICULTURE AND THE POTENTIAL TO MISLEAD

    Directory of Open Access Journals (Sweden)

    VLADU ALINA BEATTRICE

    2013-08-01

    Full Text Available Applying fair value measurement to tangible and intangible assets in agriculture cannot be risk free. Twofoldreasons can be brought into attention for the above statement: fair value estimation and the specific of agriculturefield. The purpose of this discussion paper is to underline potential creative accounting demarches that can appear inthis context. The paper concludes based on the discussions approached in the literature. Further avenues of researchare discussed.

  5. Measuring the value of internal audit in the banking industry

    Directory of Open Access Journals (Sweden)

    Clara-Iulia Zinca (Voiculescu

    2016-09-01

    The results of the study suggest that most organizations use methods that contain mainly quantitative and less qualitative elements. There are differences between banks and other types of organizations in terms of the methods and practices used, but also on the importance showed to measurement of internal audit value. In addition, the findings confirm that there is room for improving the methods and practices used, so that the audit function gains value and credibility.

  6. Measure-valued solutions to the complete Euler system revisited

    Science.gov (United States)

    Březina, Jan; Feireisl, Eduard

    2018-06-01

    We consider the complete Euler system describing the time evolution of a general inviscid compressible fluid. We introduce a new concept of measure-valued solution based on the total energy balance and entropy inequality for the physical entropy without any renormalization. This class of so-called dissipative measure-valued solutions is large enough to include the vanishing dissipation limits of the Navier-Stokes-Fourier system. Our main result states that any sequence of weak solutions to the Navier-Stokes-Fourier system with vanishing viscosity and heat conductivity coefficients generates a dissipative measure-valued solution of the Euler system under some physically grounded constitutive relations. Finally, we discuss the same asymptotic limit for the bi-velocity fluid model introduced by H.Brenner.

  7. International Accounting Convergence in the Field of Fair Value Measurement

    Directory of Open Access Journals (Sweden)

    Diana Cozma Ighian

    2015-09-01

    Full Text Available The investors’ desire for high-quality, internationally comparable financial information that is useful for decision-making in increasingly global capital markets imposed an international convergence, the ultimate goal of which is a single set of international accounting standards that companies worldwide would use for both domestic and cross-border financial reporting. The guidance, set out in IFRS 13 Fair Value Measurement and the update to Topic 820 (formerly referred to as SFAS 157, completes a major project of the boards’ joint work to improve IFRSs and US GAAP and to bring about their convergence. This article describes the controversial history of fair value measurement and the main novelties in the field of fair value measurement, arising from the international convergence process.

  8. Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures

    OpenAIRE

    Landowska Agnieszka

    2014-01-01

    This paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment is described, that aimed at practical evaluation of measurement procedures performed at the emotion monitoring stand...

  9. Calibration measurements using the ORNL fissile mass flow monitor

    International Nuclear Information System (INIS)

    March-Leuba, J.; Uckan, T.; Sumner, J.; Mattingly, J.; Mihalczo, J.

    1998-01-01

    This paper presents a demonstration of fissile-mass-flow measurements using the Oak Ridge National Laboratory (ORNL) Fissile Mass Flow Monitor in the Paducah Gaseous Diffusion Plant (PGDP). This Flow Monitor is part of a Blend Down Monitoring System (BDMS) that will be installed in at least two Russian Federation (R.F.) blending facilities. The key objectives of the demonstration of the ORNL Flow Monitor are two: (a) demonstrate that the ORNL Flow Monitor equipment is capable of reliably monitoring the mass flow rate of 235 UF 6 gas, and (b) provide a demonstration of ORNL Flow Monitor system in operation with UF 6 flow for a visiting R.F. delegation. These two objectives have been met by the PGDP demonstration, as presented in this paper

  10. Measuring techniques for continuous monitoring of bioreactors

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlmann, W; Meyer, H D; Schuegerl, K

    1982-01-01

    Control apparatus for fermentation reactors is described. In the example of alcohol fermentation by Saccharomyces cerevisiae, mass spectrometry is used for measuring soluble volatile components (CO/sub 2/, EtOH, and H/sub 2/O) and low-molecular-weight soluble components are separated by cross flow membrane filtration for measurement: D glucose by polarimetry, phosphate by photometry, and NH/sup 4 +/ by potentiometry.

  11. Weak measurements and quantum weak values for NOON states

    Science.gov (United States)

    Rosales-Zárate, L.; Opanchuk, B.; Reid, M. D.

    2018-03-01

    Quantum weak values arise when the mean outcome of a weak measurement made on certain preselected and postselected quantum systems goes beyond the eigenvalue range for a quantum observable. Here, we propose how to determine quantum weak values for superpositions of states with a macroscopically or mesoscopically distinct mode number, that might be realized as two-mode Bose-Einstein condensate or photonic NOON states. Specifically, we give a model for a weak measurement of the Schwinger spin of a two-mode NOON state, for arbitrary N . The weak measurement arises from a nondestructive measurement of the two-mode occupation number difference, which for atomic NOON states might be realized via phase contrast imaging and the ac Stark effect using an optical meter prepared in a coherent state. The meter-system coupling results in an entangled cat-state. By subsequently evolving the system under the action of a nonlinear Josephson Hamiltonian, we show how postselection leads to quantum weak values, for arbitrary N . Since the weak measurement can be shown to be minimally invasive, the weak values provide a useful strategy for a Leggett-Garg test of N -scopic realism.

  12. Measurement and monitoring technologies are important SITE program component

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    An ongoing component of the Superfund Innovative Technologies Evaluation (SITE) Program, managed by the US EPA at its Hazardous Waste Engineering Research Laboratory in Cincinnati, is the development and demonstration of new and innovative measurement and monitoring technologies that will be applicable to Superfund site characterization. There are four important roles for monitoring and measurement technologies at Superfund sites: (1) to assess the extent of contamination at a site, (2) to supply data and information to determine impacts to human health and the environment, (3) to supply data to select the appropriate remedial action, and (4) to monitor the success or effectiveness of the selected remedy. The Environmental Monitoring Systems Laboratory in Las Vegas, Nevada (EMSL-LV) has been supporting the development of improved measurement and monitoring techniques in conjunction with the SITE Program with a focus on two areas: Immunoassay for toxic substances and fiber optic sensing for in-situ analysis at Superfund sites

  13. Measurement of half-value layer in mammography

    CERN Document Server

    Yagi, H; Saruwatari, R; Doi, N; Yamane, E

    2003-01-01

    The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology. The manual prescribes exactly the geometry of measurement, chamber position of measurement in the field, selection of chamber, and so on. However, the measurement of HVL is difficult in the actual clinical setting. This study examined the results of failure to perform the measurement of HVL in accordance with the manual for measuring HVL in the clinical setting. The investigation indicated that serious problems do not arise when measuring HVL for routine quality control even if the chamber in the field is not always set according to the manual and if a chamber for radiotherapy or diagnosis is used that is not recommended for soft X-ray by the manual. (author)

  14. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    Science.gov (United States)

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  15. Environmental radioactivity. Measurement and monitoring; Umweltradioaktivitaet. Messung und Ueberwachung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-11-15

    The contribution on environmental radioactivity covers the following issues: natural and artificial radioactivity; continuous monitoring of radioactivity; monitoring authorities and measurement; radioactivity in the living environment; radioactivity in food and feeding stuff; radioactivity of game meat and wild-growing mushrooms; radioactivity in mines; radioactivity in the research center Rossendorf.

  16. Electrostatic discharges and their effect on the validity of registered values in intracranial pressure monitors

    DEFF Research Database (Denmark)

    Andresen, Morten; Thomsen, Ole Cornelius; Juhler, Marianne

    2013-01-01

    Object Intracranial pressure (ICP) monitoring is used extensively in clinical practice, and as such, the accuracy of registered ICP values is paramount. Clinical observations of nonphysiological changes in ICP have called into question the accuracy of registered ICP values. Subsequently, the auth......Object Intracranial pressure (ICP) monitoring is used extensively in clinical practice, and as such, the accuracy of registered ICP values is paramount. Clinical observations of nonphysiological changes in ICP have called into question the accuracy of registered ICP values. Subsequently......, the authors have tried to determine if the ICP monitors from major manufacturers were affected by electrostatic discharges (ESDs), if the changes were permanent or transient in nature, and if the changes were modified by the addition of different electrical appliances normally used in the neurointensive care....... Results Five pressure monitors from 4 manufacturers were evaluated. Three monitors containing electrical circuitry at the tip of the transducer were all affected by ESDs. Clinically significant permanent changes in the reported ICP values for 1 pressure monitor were observed, as well as temporary...

  17. CHALLENGES INCURRED IN THE AUDITING OF FAIR VALUE MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    Silviu-Virgil Chiriac

    2016-07-01

    Full Text Available The purpose of the auditors' work is to establish confidence between the producers and users of accounting information. Thus, auditors help protect the interests of different categories of beneficiaries of accounting information when they make economic decisions. The prevalence of fair values in the financial statements as their inherent measurement uncertainty has increased dramatically in recent years and is recognized as representing a significant problem for regulators. In these circumstances we ask which are the difficulties encountered by auditors in auditing fair values, what kinds of deficiencies they find within auditing and whether the complexity of measurements of fair value jeopardizes the ability of auditors to give a highly secure opinion.

  18. Against Journal Articles for Measuring Value in University Output

    Science.gov (United States)

    Mbali, C.

    2010-01-01

    The following lines of arguments against the metrics of journal articles is developed: (1) Textual output should no longer be main valued output; (2) Digitalization enables other ways of advancing knowledge; (3) Measures by journal article favours the disciplines of Natural Science and Engineering (NSE) and moulds other disciplines of Social…

  19. Valuing Informal Care Experience: Does Choice of Measure Matter?

    Science.gov (United States)

    Mentzakis, Emmanouil; McNamee, Paul; Ryan, Mandy; Sutton, Matthew

    2012-01-01

    Well-being equations are often estimated to generate monetary values for non-marketed activities. In such studies, utility is often approximated by either life satisfaction or General Health Questionnaire scores. We estimate and compare monetary valuations of informal care for the first time in the UK employing both measures, using longitudinal…

  20. Measuring the strategic value of information technology investments

    International Nuclear Information System (INIS)

    Conrad, K.W.

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper

  1. Measuring the strategic value of information technology investments

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, K.W. [Boeing Computer Services Co., Richland, WA (United States)

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper.

  2. Measuring and Communicating the Value Created by an Organization

    Science.gov (United States)

    Sherman, W. Richard

    2010-01-01

    This paper offers a different perspective in measuring the value created by an organization. It does so in the context of an undergraduate course in managerial accounting. In order to break down the functional silo approach to problem solving that has become the model of traditional business education, applications of shadow accounting, the…

  3. Low diagnostic value of respiratory impedance measurements in children

    NARCIS (Netherlands)

    Cuijpers, CEJ; Wesseling, GJ; Kessels, AGH; Swaen, GMH; Mertens, PLJM; deKok, ME; Broer, J; Sturmans, F; Wouters, EFM

    The aim of this study was to determine whether impedance values in children with various chronic respiratory complaints differed from those observed in symptom-free children. Respiratory impedance was measured using the forced oscillation technique in 1,776 Dutch children aged 6-12 yrs. In addition

  4. How to Use Value-Added Measures Right

    Science.gov (United States)

    Di Carlo, Matthew

    2012-01-01

    Value-added models are a specific type of "growth model," a diverse group of statistical techniques to isolate a teacher's impact on his or her students' testing progress while controlling for other measurable factors, such as student and school characteristics, that are outside that teacher's control. Opponents, including many teachers, argue…

  5. Positive-operator-valued measure optimization of classical correlations

    NARCIS (Netherlands)

    Hamieh, S; Kobes, R; Zaraket, H

    We study the problem of optimization over positive-operator-valued measures to extract classical correlation in a bipartite quantum system. The proposed method is applied to binary states only. Moreover, to illustrate this method, an explicit example is studied in detail.

  6. Accurate Q value measurements for fundamental physics studies at JYFLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Eronen, T., E-mail: tommi.o.eronen@jyu.fi; Kolhinen, V. S. [University of Jyvaeskylae (Finland); Collaboration: JYFLTRAP collaboration

    2011-07-15

    We have measured several Q values at JYFLTRAP for superallowed {beta} decays that contribute to testing the Standard Model and candidate nuclei that one could use for the search of neutrinoless double-{beta} decay. These results play important roles in the research of fundamental physics that have scopes beyond Standard Model.

  7. Emotion Monitoring – Verification of Physiological Characteristics Measurement Procedures

    Directory of Open Access Journals (Sweden)

    Landowska Agnieszka

    2014-12-01

    Full Text Available This paper concerns measurement procedures on an emotion monitoring stand designed for tracking human emotions in the Human-Computer Interaction with physiological characteristics. The paper addresses the key problem of physiological measurements being disturbed by a motion typical for human-computer interaction such as keyboard typing or mouse movements. An original experiment is described, that aimed at practical evaluation of measurement procedures performed at the emotion monitoring stand constructed at GUT. Different locations of sensors were considered and evaluated for suitability and measurement precision in the Human- Computer Interaction monitoring. Alternative locations (ear lobes and forearms for skin conductance, blood volume pulse and temperature sensors were proposed and verified. Alternative locations proved correlation with traditional locations as well as lower sensitiveness to movements like typing or mouse moving, therefore they can make a better solution for monitoring the Human-Computer Interaction.

  8. Luminosity monitoring and measurement at CDF

    International Nuclear Information System (INIS)

    Cronin-Hennessy, D.; Beretvas, A.; Derwent, P.F.

    2000-01-01

    Using two telescopes of beam-beam counters, CDF (Collider Detector at Fermilab) has measured the luminosity to an accuracy of 4.1% (3.6%) in run Ib (Ia). For run Ib (Ia) the average luminosity was 9.1(3.3)x10 30 cm -2 s -1 . For a typical data set the integrated luminosity was 86.47 (19.65) pb -1 in run Ib (Ia) resulting in a total integrated luminosity of 106.1±4.1 pb -1 . This paper shows how we have determined the accuracy of our results

  9. The Value of Improved Measurements in a Pig Slaughterhouse

    DEFF Research Database (Denmark)

    Kjærsgaard, Niels Christian

    The pig industry is an essential and important part of Danish economy with an export value in 2006 of more than DKK 28 billions [Danish Meat Association (2007)]. The competition is hard, and potential new competitors from low cost countries can be expected to enter the traditional Danish export...... markets. Therefore it is more important than ever to optimize all aspects of Danish pig production, slaughtering processes and delivery. This paper concerns the aspects of optimization at the slaughterhouses regarding estimation of the value of improved measurements. The slaughterhouse industry differs...... investments are expected to improve the quality of the measurements further. This paper concerns the use of Operations Research to solve a practical problem, which is of major importance for the industry, namely to improve the estimation of the economic effects of improved measurements. The benefit...

  10. Evaluation of measurement precision errors at different bone density values

    International Nuclear Information System (INIS)

    Wilson, M.; Wong, J.; Bartlett, M.; Lee, N.

    2002-01-01

    Full text: The precision error commonly used in serial monitoring of BMD values using Dual Energy X Ray Absorptometry (DEXA) is 0.01-0.015g/cm - for both the L2 L4 lumbar spine and total femur. However, this limit is based on normal individuals with bone densities similar to the population mean. The purpose of this study was to systematically evaluate precision errors over the range of bone density values encountered in clinical practice. In 96 patients a BMD scan of the spine and femur was immediately repeated by the same technologist with the patient taken off the bed and repositioned between scans. Nine technologists participated. Values were obtained for the total femur and spine. Each value was classified as low range (0.75-1.05 g/cm ) and medium range (1.05- 1.35g/cm ) for the spine, low range (0.55 0. 85 g/cm ) and medium range (0.85-1.15 g/cm ) for the total femur. Results show that the precision error was significantly lower in the medium range for total femur results with the medium range value at 0.015 g/cm - and the low range at 0.025 g/cm - (p<0.01). No significant difference was found for the spine results. We also analysed precision errors between three technologists and found a significant difference (p=0.05) occurred between only two technologists and this was seen in the spine data only. We conclude that there is some evidence that the precision error increases at the outer limits of the normal bone density range. Also, the results show that having multiple trained operators does not greatly increase the BMD precision error. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. Value of self-monitoring blood glucose pattern analysis in improving diabetes outcomes.

    Science.gov (United States)

    Parkin, Christopher G; Davidson, Jaime A

    2009-05-01

    Self-monitoring of blood glucose (SMBG) is an important adjunct to hemoglobin A1c (HbA1c) testing. This action can distinguish between fasting, preprandial, and postprandial hyperglycemia; detect glycemic excursions; identify and monitor resolution of hypoglycemia; and provide immediate feedback to patients about the effect of food choices, activity, and medication on glycemic control. Pattern analysis is a systematic approach to identifying glycemic patterns within SMBG data and then taking appropriate action based upon those results. The use of pattern analysis involves: (1) establishing pre- and postprandial glucose targets; (2) obtaining data on glucose levels, carbohydrate intake, medication administration (type, dosages, timing), activity levels and physical/emotional stress; (3) analyzing data to identify patterns of glycemic excursions, assessing any influential factors, and implementing appropriate action(s); and (4) performing ongoing SMBG to assess the impact of any therapeutic changes made. Computer-based and paper-based data collection and management tools can be developed to perform pattern analysis for identifying patterns in SMBG data. This approach to interpreting SMBG data facilitates rational therapeutic adjustments in response to this information. Pattern analysis of SMBG data can be of equal or greater value than measurement of HbA1c levels. 2009 Diabetes Technology Society.

  12. Measuring Emotional Responses to TV Commercials: The Warmth Monitor Modernized

    Directory of Open Access Journals (Sweden)

    Marc Roy

    2014-12-01

    Full Text Available Recently there has been a lot of interest in measuring emotional responses to advertising. This study focuses on the measurement of a specific emotional response to television advertising; warmth. Nearly thirty years ago, (Aaker, Stayman and Hagerty, 1986 developed a procedure they called the Warmth Monitor; “paper and pencil” self-report process recording method. The Warmth Monitor has been used in a large number of empirical studies in marketing since, but the most recent versions of the procedure are computerized. The two methods of administering the Warmth Monitor are compared in this research.

  13. Conjectures Regarding the Adoption of Fair Value Measurements in Brazil

    Directory of Open Access Journals (Sweden)

    Fernando Dal-Ri Murcia

    2008-01-01

    Full Text Available The issue of relevance versus reliability has always been a debate in accounting. Far from being a consensus among the community, the adoption of fair value measurements is intended to present a more realistic view of an entity¿s financial position. However, it could also cause a loss of credibility due to the subjectivity inherent in the valuation process. Wishing to make a contribution to the existing literature on this issue, this paper presents a discussion about the adoption of fair value measurements in Brazil. First, we present a brief examination of asset and liability valuation using the accounting theory as a framework. Following, we conduct a review of the International Accounting Standards Board (IASB and the Financial Accounting Standards Board (FASB standards regarding fair value measurements. Empirical studies addressing fair value are also reviewed. Finally, a discussion about its implementation is presented, aiming to take into account the specificities of the Brazilian Market. This paper intends to contribute to the construction of academic knowledge in accounting by debating an issue which is a real problem for organizations, and yet incipient in the national literature.

  14. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring

    OpenAIRE

    Mark van Gastel; Sander Stuijk; Gerard de Haan

    2016-01-01

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO2) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted ...

  15. Radiation monitoring and measuring instrument developed by Turkish Atomic Energy Authority

    International Nuclear Information System (INIS)

    Kuecuekarslan, N.; Gueven, A.

    2001-01-01

    Turkish Atomic Energy Authority (TAEA), Cekmece Nuclear Research and Training Center, Nuclear Electronics Department is working on research, development and production of radiation monitoring and measuring instruments in the aims of TAEA to serve our Country. Advanced micro controller technology is used to cover problems of radiation measurement. Control by micro controller enables reliable, stable measurement and display of low level dose rate fields. It makes possible the simultaneous measurement of both dose and dose rate values

  16. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    OpenAIRE

    Thomas, Felicity Louise; Signal, Mathew; Harris, Deborah L.; Weston, Philip J.; Harding, Jane E.; Shaw, Geoffrey M.; Chase, J. Geoffrey

    2014-01-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia me...

  17. A universal measuring and monitoring system for nuclear radiation

    International Nuclear Information System (INIS)

    Genrich, V.

    1988-01-01

    Genitron Instruments, Frankfurt/Main, committed themselves to revise the 'conventional' concept of counting tube metrology. The goal was to develop a modular system that would allow large-area measuring tasks. The contribution in hand explains this development, which consists of a highly integrated measuring head that can be combined with various detector types, and complemented by various system components, to form a universal measuring and monitoring system for nuclear radiation. This modular design concept is capable of fulfilling a multitude of tasks, ranging from single, specific applications to non-stop monitoring tasks within a large-area measuring network. (orig./DG) [de

  18. Development and validation of a measure of food choice values.

    Science.gov (United States)

    Lyerly, Jordan E; Reeve, Charlie L

    2015-06-01

    Food choice values (FCVs) are factors that individuals consider when deciding which foods to purchase and/or consume. Given the potentially important implications for health, it is critical for researchers to have access to a validated measure of FCV. Though there is an existing measure of FCV, this measure was developed 20 years ago and recent research suggests additional FCVs exist that are not included in this measure. A series of four studies was conducted to develop a new expanded measure of FCV. An eight-factor model of FCV was supported and confirmed. In aggregate, results from the four studies indicate that the measure is content valid, and has internally consistent scales that also demonstrated acceptable temporal stability and convergent validity. In addition, the eight scales of the measures were independent of social desirability, met criteria for measurement invariance across income groups, and predicted dietary intake. The development of this new measure of FCV may be useful for researchers examining FCVs (FCVs) in the future, as well as for use in intervention and prevention efforts targeting dietary choices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Evaluation of indices for voltage stability monitoring using PMU measurements

    Directory of Open Access Journals (Sweden)

    Sindy Lorena Ramirez Perdomo

    2014-09-01

    Full Text Available Large disturbances such as voltage collapse and its consequences represent a large challenge to the operational safety of power systems. Therefore, it is important to have indicators of the presence of voltage stability problems in real time. Using phasor measure-ments of voltage and current that are presented in Phasor Measurement Units (PMU, indices for voltage stability monitoring can be calculated in real time. This paper presents some indices for voltage stability monitoring using PMU measurements. Evaluation of such indices on a simplified system was carried out, and the indices were classified according to their method of calculation. Finally, one of these indices was used with the New England 39-bus system under different operating scenarios, including load increments, line output and generator output, to check the indices’ behavior for voltage stability monitoring based on synchronized local measurements.

  20. Reference value sensitivity of measures of unfair health inequality

    Science.gov (United States)

    García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom

    2014-01-01

    Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998

  1. Quantification of the Value of Structural Health Monitoring Information for Fatigue Deteriorating Structural Systems

    DEFF Research Database (Denmark)

    Thöns, Sebastian; Schneider, Ronald; Faber, Michael Havbro

    2015-01-01

    This paper addresses the quantification of the value of structural health monitoring (SHM) before its implementation for structural systems on the basis of its Value of Information (VoI). The value of SHM is calculated utilizing the Bayesian pre-posterior decision analysis modelling the structural...... life cycle performance, the integrity management and the structural risks. The relevance and precision of SHM information for the reduction of the structural system risks and the expected cost of the structural integrity management throughout the life cycle constitutes the value of SHM...... and is quantified with this framework. The approach is focused on fatigue deteriorating structural steel systems for which a continuous resistance deterioration formulation is introduced. In a case study, the value of SHM for load monitoring is calculated for a Daniels system subjected to fatigue deterioration...

  2. The Predictive Value of Inflammation-Related Peripheral Blood Measurements in Cancer Staging and Prognosis

    Directory of Open Access Journals (Sweden)

    Joanna L. Sylman

    2018-03-01

    Full Text Available In this review, we discuss the interaction between cancer and markers of inflammation (such as levels of inflammatory cells and proteins in the circulation, and the potential benefits of routinely monitoring these markers in peripheral blood measurement assays. Next, we discuss the prognostic value and limitations of using inflammatory markers such as neutrophil-to-lymphocyte and platelet-to-lymphocyte ratios and C-reactive protein measurements. Furthermore, the review discusses the benefits of combining multiple types of measurements and longitudinal tracking to improve staging and prognosis prediction of patients with cancer, and the ability of novel in silico frameworks to leverage this high-dimensional data.

  3. Measure-valued solutions to the complete Euler system revisited

    Czech Academy of Sciences Publication Activity Database

    Březina, J.; Feireisl, Eduard

    2018-01-01

    Roč. 69, č. 3 (2018), č. článku 57. ISSN 0044-2275 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : Euler system * measure-valued solution * vanishing dissipation limit Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.687, year: 2016 https://link.springer.com/article/10.1007/s00033-018-0951-8

  4. Positive Operator Valued Measures: A General Setting for Frames

    OpenAIRE

    Moran, Bill; Howard, Stephen; Cochran, Doug

    2011-01-01

    This paper presents an overview of close parallels that exist between the theory of positive operator-valued measures (POVMs) associated with a separable Hilbert space and the theory of frames on that space, including its most important generalizations. The concept of a framed POVM is introduced, and classical frames, fusion frames, generalized frames, and other variants of frames are all shown to to arise as framed POVMs. This observation allows drawing on a rich existing theory of POVMs to ...

  5. Value of a radioimmunological monitoring in cancer patients treated with interferon alpha

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, J.; Franchimont, P. (University of Liege, Institute of Pathology (Belgium)); Reuter, A.; Vrindts-Gevaert, Y. (National Institute of Radioelements, Fleurus (Belgium)); Pouillart, P.; Bretaudeau, B.; Falcoff, E.; Magdelenat, H. (Institut Curie, 75 - Paris (France))

    1984-01-01

    Using a radioimmunoassy for human leukocyte interferon (IFN..cap alpha..), pharmacokinetic studies were carried out in twelve cancer patients given sequential intramuscular injections of Hu IFN..cap alpha../sub 2/. Even though individual monitoring of serum IFN titers emphasized for a given dose, marked quantitative variations of the observed maximum concentrations, their mean values were found to be dose-dependent (358+-167 U/ml at 30.10/sup 6/ U and 1044+-599 U/ml at 100.10/sup 6/ U doses). Comparison with bioassay results showed that IFN activities measured in sera were of the same order of magnitude as those calculated from radioimmunoassay standard curves. Data obtained from this series on observed peak time, half-life value and serum concentrations were consistent with those reported by the other groups using recombinant leukocyte interferon in clinical trial. Therefore, radioimmunoassay is an useful method for routinely assaying IFN..cap alpha.. used either as antitumour or antivirus agent because of its high sensitivity (4 U/ml) and its simplicity.

  6. Measuring Nursing Value from the Electronic Health Record.

    Science.gov (United States)

    Welton, John M; Harper, Ellen M

    2016-01-01

    We report the findings of a big data nursing value expert group made up of 14 members of the nursing informatics, leadership, academic and research communities within the United States tasked with 1. Defining nursing value, 2. Developing a common data model and metrics for nursing care value, and 3. Developing nursing business intelligence tools using the nursing value data set. This work is a component of the Big Data and Nursing Knowledge Development conference series sponsored by the University Of Minnesota School Of Nursing. The panel met by conference calls for fourteen 1.5 hour sessions for a total of 21 total hours of interaction from August 2014 through May 2015. Primary deliverables from the bit data expert group were: development and publication of definitions and metrics for nursing value; construction of a common data model to extract key data from electronic health records; and measures of nursing costs and finance to provide a basis for developing nursing business intelligence and analysis systems.

  7. Demonstrating the viability and value of community-based monitoring schemes in catchment science

    Science.gov (United States)

    Starkey, Eleanor; Parkin, Geoff; Quinn, Paul; Large, Andy

    2016-04-01

    Hydrological catchments are complex systems which need to be monitored over time in order to characterise their behaviour on a local level, model, implement mitigation measures and meet policy targets. Despite hydrometric monitoring techniques being well developed, data is often inadequate within rural areas. Local knowledge and experiences are also vital sources of information in this sector but they are not routinely harvested. Long-term evidence is required to provide stakeholders with confidence and innovation is required to fully engage with and inform the public. Citizen science and volunteered geographical information (VGI) projects are encouraging volunteers to participate in crowdsourcing activities and generate new knowledge, but they have not been fully investigated within catchment science. A citizen science approach has therefore been implemented within the 42km2 Haltwhistle Burn catchment (northern England) using effective engagement techniques. This catchment responds rapidly, experiences flash flood events, and like many, it does not benefit from any traditional monitoring equipment. Participation levels confirm that members of the public do want to monitor their local water environment, with flooding being a key driver. Regular 'River Watch' volunteers and passers-by are sharing their knowledge and monitoring rainfall, river levels, water quality parameters, sediment issues, flood events and performance of flood risk management features. This has enabled a variety of low-cost data collection and submission tools to be tested over a two year period. Training has encouraged good quality data to be collected and volunteers are ready to capture meaningful information during unexpected flood events. Although volunteers are capable of collecting quantitative information, photographs and videos are submitted more readily. Twitter has also been used to share real-time observations successfully. A traditional monitoring network has been running in parallel

  8. Designing the Monitoring of Water-Related Sustainable Development Goals Based on Value of Information

    Science.gov (United States)

    Chen, R. S.; Levy, M. A.; de Sherbinin, A. M.; Fischer, A.

    2015-12-01

    The proposed Sustainable Development Goals (SDGs) represent an unprecedented international commitment to collective action and targeted interventions at global, regional, and national scales. Existing monitoring and data infrastructures are inadequate for producing the variety of environmental and socioeconomic information needed to ensure efficient and effective outcomes across the range of interlinked SDGs and targets. The scientific community needs to take a lead in developing new tools and approaches that, at reasonable cost, provide monitoring data of sufficient quality and spatial and temporal coverage to support informed decision making by diverse stakeholders. The expanded SDGs related to water offer the opportunity to explore potential new monitoring approaches and data system architectures in a key sector, building on existing water monitoring capabilities and incorporating new technologies and methods. Since additional investments in monitoring will undoubtedly be limited, it is important to assess carefully the value of information produced by different options and their associated risks and tradeoffs. We review here the existing set of water monitoring systems, known gaps and limitations, stakeholder inputs on data needs, and the potential value of information in light of alternative water sector interventions. Of particular interest are opportunities to share investments in monitoring across sectors and stakeholders (e.g., public and private entities) and to identify where incremental improvements in water monitoring could have significant benefits for other SDGs (e.g., related to health, energy, agriculture, and climate change). Value of information is also driven by the numbers of people affected by decisions or able to take advantage of improved data, which implies the need not only to collect and archive data, but also to invest in making data accessible and usable to diverse and geographically dispersed users.

  9. Measuring Value in Internal Medicine Residency Training Hospitals Using Publicly Reported Measures.

    Science.gov (United States)

    Schickedanz, Adam; Gupta, Reshma; Arora, Vineet M; Braddock, Clarence H

    2018-03-01

    Graduate medical education (GME) lacks measures of resident preparation for high-quality, cost-conscious practice. The authors used publicly reported teaching hospital value measures to compare internal medicine residency programs on high-value care training and to validate these measures against program director perceptions of value. Program-level value training scores were constructed using Centers for Medicare & Medicaid Services Value-Based Purchasing (VBP) Program hospital quality and cost-efficiency data. Correlations with Association of Program Directors in Internal Medicine Annual Survey high-value care training measures were examined using logistic regression. For every point increase in program-level VBP score, residency directors were more likely to agree that GME programs have a responsibility to contain health care costs (adjusted odds ratio [aOR] 1.18, P = .04), their faculty model high-value care (aOR 1.07, P = .03), and residents are prepared to make high-value medical decisions (aOR 1.07, P = .09). Publicly reported clinical data offer valid measures of GME value training.

  10. Electromagnetic fields and health impact: measurements, monitoring and environmental indicators

    International Nuclear Information System (INIS)

    Lubritto, C.; Vetromile, C.; Petraglia, A.; Racioppoli, M.; D'Onofrio, A.

    2008-01-01

    Full text: During the last 10 years there has been a remarkable growth of the attention for problems related to the electromagnetic pollution, motivated by the alert connected to potential risk for the health of persons and due to the increasing diffusion of Bats for mobile telecommunication as EMF sources. Many projects are being realized about the environmental and health impact of electromagnetic field and an important social role is played by specific actions to minimize the risk perception of the population. This study aims to find an innovative approach to these problems through the use of a system of continuous time monitoring of the electromagnetic fields and the individuation of appropriate environmental indicators. The proposed system monitors the electromagnetic fields continuously over time, and is already operating in many southern Italian cities. It works in a very efficient way as a mean for: a) Info to the citizens, thanks to diffusion of daily collected data on Internet Web; b) Control for local administrations and Authorities, due to capability of the system itself to alert when measured values exceed the limits reported by the Italian laws; c) Planning, for the implementation of : 1) New procedures agreed among local environmental control agency, local administrations and mobile Companies for network planning and management of alarm situations; 2) New local guidelines documents concerning the installation and operation of telecommunications apparatus. Moreover, starting from the general principles of the Strategic Environmental Evaluation (VAS), the environmental impacts of EMS field is studied. Based on the model DPSIR (Drivers, Pressure, State, Impacts, Responses), 12 environmental indicators have been chosen providing an immediate and understandable tool to obtain very important information on electromagnetic pollution generated by radio-telecommunication systems. The selected environmental indicators have been applied to 11 cities of the

  11. Reference values and their application to the monitoring of occupational exposure to natural uranium compounds

    International Nuclear Information System (INIS)

    1986-09-01

    Natural uranium compounds, which enter the oxide fuel cycle offer physico-chemical characteristics dependent on their structure and their production process. These characteristics govern their biological behaviour and the degree of their radioactive and chemical toxicity. The monitoring of workers occupationnally exposed to these compounds is carried out by bioassays; in order to get the best interpretation, the resulting data must be compared to reference values. These values must be closely related to the type of contaminant and the real exposure conditions. In this report, the occupational medicine services working group has examined the possibilities of obtaining such reference values and suggests recommendations and operational values covering most situations found in routine monitoring [fr

  12. Uncertainty Quantification for Monitoring of Civil Structures from Vibration Measurements

    Science.gov (United States)

    Döhler, Michael; Mevel, Laurent

    2014-05-01

    Health Monitoring of civil structures can be performed by detecting changes in the modal parameters of a structure, or more directly in the measured vibration signals. For a continuous monitoring the excitation of a structure is usually ambient, thus unknown and assumed to be noise. Hence, all estimates from the vibration measurements are realizations of random variables with inherent uncertainty due to (unknown) process and measurement noise and finite data length. In this talk, a strategy for quantifying the uncertainties of modal parameter estimates from a subspace-based system identification approach is presented and the importance of uncertainty quantification in monitoring approaches is shown. Furthermore, a damage detection method is presented, which is based on the direct comparison of the measured vibration signals without estimating modal parameters, while taking the statistical uncertainty in the signals correctly into account. The usefulness of both strategies is illustrated on data from a progressive damage action on a prestressed concrete bridge. References E. Carden and P. Fanning. Vibration based condition monitoring: a review. Structural Health Monitoring, 3(4):355-377, 2004. M. Döhler and L. Mevel. Efficient multi-order uncertainty computation for stochastic subspace identification. Mechanical Systems and Signal Processing, 38(2):346-366, 2013. M. Döhler, L. Mevel, and F. Hille. Subspace-based damage detection under changes in the ambient excitation statistics. Mechanical Systems and Signal Processing, 45(1):207-224, 2014.

  13. Measure-valued differentiation for finite products of measures : theory and applications

    NARCIS (Netherlands)

    Leahu, H.

    2008-01-01

    In this dissertation we perform a comprehensive analysis of measure-valued differentiation, in which weak differentiation of parameter-dependent probability measures plays a central role. We develop a theory of weak differentiation of measures and show that classical concepts such as differential

  14. Value of monitoring in asset management: A social costbenefit analysis approach

    NARCIS (Netherlands)

    Zouch, M.; Courage, W.; Nápoles, O.M.

    2013-01-01

    We present a framework to investigate new monitoring techniques for infrastructures and assess their potential value for the network management. This framework is based on a social cost benefit analysis tool that aims to (i) assist decision makers in selecting and developing cost-effective new

  15. Three measures of longevity: time trends and record values

    DEFF Research Database (Denmark)

    Canudas-Romo, V

    2010-01-01

    at birth increased from a level of 44 years in Sweden in 1840 to 82 years in Japan in 2005. The record median age at death shows increasing patterns similar to those observed in life expectancy at birth. However, the record modal age at death changes very little until the second half of the twentieth......This article examines the trend over time in the measures of “typical” longevity experienced by members of a population: life expectancy at birth, and the median and modal ages at death. The article also analyzes trends in record values observed for all three measures. The record life expectancy...... time from a dominance of child mortality reductions to a dominance of adult mortality reductions, which became evident by studying trends in the record modal age at death....

  16. Monitoring of MNSR operation by measuring subcritical photoneutron flux

    International Nuclear Information System (INIS)

    Haddad, Kh.; Alsomel, N.

    2011-01-01

    Passive nondestructive assay methods are used to monitor the reactor's operation. It is required for nuclear regulatory, calculation validation and safeguards purposes. So, it plays a vital role in the safety and security of the nuclear plants. The possibility of MNSR operation monitoring by measuring the subcritical state photoneutron flux were investigated in this work. The photoneutron flux is induced by the fuels hard gamma radiation in the beryllium reflector. Theoretical formulation and experimental tests were performed. The results show that within a specified cooling time range, the photoneutron flux is induced by a single dominant hard gamma emitter such as 117 Cd (activation product) and 140 Ba ( 140 La fission product). This phenomenon was utilized to monitor the cooling time and the operation neutron flux during the last campaign. Thus a passive nondestructive assay method is proposed with regard to the reactor operation's monitoring.

  17. Measuring energy efficiency in economics: Shadow value approach

    Science.gov (United States)

    Khademvatani, Asgar

    For decades, academic scholars and policy makers have commonly applied a simple average measure, energy intensity, for studying energy efficiency. In contrast, we introduce a distinctive marginal measure called energy shadow value (SV) for modeling energy efficiency drawn on economic theory. This thesis demonstrates energy SV advantages, conceptually and empirically, over the average measure recognizing marginal technical energy efficiency and unveiling allocative energy efficiency (energy SV to energy price). Using a dual profit function, the study illustrates how treating energy as quasi-fixed factor called quasi-fixed approach offers modeling advantages and is appropriate in developing an explicit model for energy efficiency. We address fallacies and misleading results using average measure and demonstrate energy SV advantage in inter- and intra-country energy efficiency comparison. Energy efficiency dynamics and determination of efficient allocation of energy use are shown through factors impacting energy SV: capital, technology, and environmental obligations. To validate the energy SV, we applied a dual restricted cost model using KLEM dataset for the 35 US sectors stretching from 1958 to 2000 and selected a sample of the four sectors. Following the empirical results, predicted wedges between energy price and the SV growth indicate a misallocation of energy use in stone, clay and glass (SCG) and communications (Com) sectors with more evidence in the SCG compared to the Com sector, showing overshoot in energy use relative to optimal paths and cost increases from sub-optimal energy use. The results show that energy productivity is a measure of technical efficiency and is void of information on the economic efficiency of energy use. Decomposing energy SV reveals that energy, capital and technology played key roles in energy SV increases helping to consider and analyze policy implications of energy efficiency improvement. Applying the marginal measure, we also

  18. Luminosity measurement and beam condition monitoring at CMS

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, Jessica Lynn [DESY, Zeuthen (Germany)

    2015-07-01

    The BRIL system of CMS consists of instrumentation to measure the luminosity online and offline, and to monitor the LHC beam conditions inside CMS. An accurate luminosity measurement is essential to the CMS physics program, and measurement of the beam background is necessary to ensure safe operation of CMS. In expectation of higher luminosity and denser proton bunch spacing during LHC Run II, many of the BRIL subsystems are being upgraded and others are being added to complement the existing measurements. The beam condition monitor (BCM) consists of several sets of diamond sensors used to measure online luminosity and beam background with a single-bunch-crossing resolution. The BCM also detects when beam conditions become unfavorable for CMS running and may trigger a beam abort to protect the detector. The beam halo monitor (BHM) uses quartz bars to measure the background of the incoming beams at larger radii. The pixel luminosity telescope (PLT) consists of telescopes of silicon sensors designed to provide a CMS online and offline luminosity measurement. In addition, the forward hadronic calorimeter (HF) will deliver an independent luminosity measurement, making the whole system robust and allowing for cross-checks of the systematics. Data from each of the subsystems will be collected and combined in the BRIL DAQ framework, which will publish it to CMS and LHC. The current status of installation and commissioning results for the BRIL subsystems are given.

  19. Ambulatory blood pressure monitoring after 1 year on valsartan or amlodipine-based treatment: a VALUE substudy

    DEFF Research Database (Denmark)

    Pedersen, Ole Lederballe; Mancia, Giuseppe; Pickering, Thomas

    2007-01-01

    OBJECTIVE: The ambulatory blood pressure (ABP) monitoring substudy of the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial was carried out in a subset of patients from USA, Italy and Denmark. ABP was measured after 1 year in the trial, with the aim of evaluating comparability...... of ABP levels on valsartan (VAL) and amlodipine (AML)-based regimens. METHODS: ABP was measured every 20 min during a 25-h period after morning administration of medicine; 659 patients were available for intention-to-treat analysis. RESULTS: Office blood pressure (BP) differences were smaller than...

  20. Incorporation monitoring by measurements of activity concentrations in air

    International Nuclear Information System (INIS)

    Breukelmann, G.; Dalheimer, A.; Dilger, H.; Henrichs, K.

    1997-01-01

    The incorporation monitoring of workers handling actinides is in many cases not possible by individual methods: The sensitivity of bioassay of methods (in vivo, in vitro) is not sufficient to detect amounts as required by the low annual limits of intake. Similar difficulties may occur with the use of radionuclides with very short physical half-lives. In these cases, the measuring of activity concentrations in the air is the only way to monitor the workers and to meet legal requirements. The essential problem connected with this approach is to make sure, that the air sample analyzed represents the average air inhaled actually. Correspondingly, the new system regulating the incorporation monitoring in Germany requires additional measures to ensure this representatively. (author)

  1. Value of information analysis for groundwater quality monitoring network design Case study: Eocene Aquifer, Palestine

    Science.gov (United States)

    Khader, A.; McKee, M.

    2010-12-01

    Value of information (VOI) analysis evaluates the benefit of collecting additional information to reduce or eliminate uncertainty in a specific decision-making context. It makes explicit any expected potential losses from errors in decision making due to uncertainty and identifies the “best” information collection strategy as one that leads to the greatest expected net benefit to the decision-maker. This study investigates the willingness to pay for groundwater quality monitoring in the Eocene Aquifer, Palestine, which is an unconfined aquifer located in the northern part of the West Bank. The aquifer is being used by 128,000 Palestinians to fulfill domestic and agricultural demands. The study takes into account the consequences of pollution and the options the decision maker might face. Since nitrate is the major pollutant in the aquifer, the consequences of nitrate pollution were analyzed, which mainly consists of the possibility of methemoglobinemia (blue baby syndrome). In this case, the value of monitoring was compared to the costs of treating for methemoglobinemia or the costs of other options like water treatment, using bottled water or importing water from outside the aquifer. And finally, an optimal monitoring network that takes into account the uncertainties in recharge (climate), aquifer properties (hydraulic conductivity), pollutant chemical reaction (decay factor), and the value of monitoring is designed by utilizing a sparse Bayesian modeling algorithm called a relevance vector machine.

  2. Light-pollution measurement with the Wide-field all-sky image analyzing monitoring system

    Science.gov (United States)

    Vítek, S.

    2017-07-01

    The purpose of this experiment was to measure light pollution in the capital of Czech Republic, Prague. As a measuring instrument is used calibrated consumer level digital single reflex camera with IR cut filter, therefore, the paper reports results of measuring and monitoring of the light pollution in the wavelength range of 390 - 700 nm, which most affects visual range astronomy. Combining frames of different exposure times made with a digital camera coupled with fish-eye lens allow to create high dynamic range images, contain meaningful values, so such a system can provide absolute values of the sky brightness.

  3. Calibration of alpha-track monitors for measurement of thoron

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1990-03-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) to provide standardization, calibration, verification of data, quality assurance, and cost-effectiveness for environmental measurements associated with the various DOE remedial action programs. The GJPO Radon Laboratory has conducted a number of studies evaluating the precision and accuracy of alpha-track monitors for the measurement of airborne radon (Rn-222) concentration. These studies have demonstrated the usefulness of using alpha-track monitors to measure radon. Alpha-track devices have also been proposed for estimating concentrations of thoron (Rn-220). 9 refs., 7 figs., 4 tabs

  4. Oxide thickness measurement for monitoring fuel performance at high burnup

    International Nuclear Information System (INIS)

    Jaeger, M.A.; Van Swam, L.F.P.; Brueck-Neufeld, K.

    1991-01-01

    For on-site monitoring of the fuel performance at high burnup, Advanced Nuclear Fuels uses the linear scan eddy current method to determine the oxide thickness of irradiated Zircaloy fuel cans. Direct digital data acquisition methods are employed to collect the data on magnetic storage media. This field-proven methodology allows oxide thickness measurements and rapid interpretation of the data during the reactor outages and makes it possible to immediately reinsert the assemblies for the next operating cycle. The accuracy of the poolside measurements and data acquisition/interpretation techniques have been verified through hot cell metallographic measurements of rods previously measured in the fuel pool. The accumulated data provide a valuable database against which oxide growth models have been benchmarked and allow for effective monitoring of fuel performance. (orig.) [de

  5. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  6. Monitoring dental erosion by colour measurement : An in vitro study

    NARCIS (Netherlands)

    Krikken, J. B.; Zijp, J. R.; Huysmans, M. C. D. N. J. M.

    Objectives: The aim of this study was to develop a method to monitor dental erosion by evaluation of the colour change of teeth as a function of enamel loss, and to evaluate the reproducibility of the method used. Methods: Light reflectance spectra of 12 extracted human incisors were measured using

  7. Ozone Measurements Monitoring Using Data-Based Approach

    KAUST Repository

    Harrou, Fouzi; Kadri, Farid; Khadraoui, Sofiane; Sun, Ying

    2016-01-01

    The complexity of ozone (O3) formation mechanisms in the troposphere make the fast and accurate modeling of ozone very challenging. In the absence of a process model, principal component analysis (PCA) has been extensively used as a data-based monitoring technique for highly correlated process variables; however conventional PCA-based detection indices often fail to detect small or moderate anomalies. In this work, we propose an innovative method for detecting small anomalies in highly correlated multivariate data. The developed method combine the multivariate exponentially weighted moving average (MEWMA) monitoring scheme with PCA modelling in order to enhance anomaly detection performance. Such a choice is mainly motivated by the greater ability of the MEWMA monitoring scheme to detect small changes in the process mean. The proposed PCA-based MEWMA monitoring scheme is successfully applied to ozone measurements data collected from Upper Normandy region, France, via the network of air quality monitoring stations. The detection results of the proposed method are compared to that declared by Air Normand air monitoring association.

  8. Ozone Measurements Monitoring Using Data-Based Approach

    KAUST Repository

    Harrou, Fouzi

    2016-02-01

    The complexity of ozone (O3) formation mechanisms in the troposphere make the fast and accurate modeling of ozone very challenging. In the absence of a process model, principal component analysis (PCA) has been extensively used as a data-based monitoring technique for highly correlated process variables; however conventional PCA-based detection indices often fail to detect small or moderate anomalies. In this work, we propose an innovative method for detecting small anomalies in highly correlated multivariate data. The developed method combine the multivariate exponentially weighted moving average (MEWMA) monitoring scheme with PCA modelling in order to enhance anomaly detection performance. Such a choice is mainly motivated by the greater ability of the MEWMA monitoring scheme to detect small changes in the process mean. The proposed PCA-based MEWMA monitoring scheme is successfully applied to ozone measurements data collected from Upper Normandy region, France, via the network of air quality monitoring stations. The detection results of the proposed method are compared to that declared by Air Normand air monitoring association.

  9. Application of maximum radiation exposure values and monitoring of radiation exposure

    International Nuclear Information System (INIS)

    1993-01-01

    According to the Section 32 of the Radiation Act (592/91) the Finnish Centre for Radiation and Nuclear Safety gives instructions concerning the monitoring of the radiation exposure and the application of the dose limits in Finland. The principles to be applied to calculating the equivalent and the effective doses are presented in the guide. Also the detailed instructions on the application of the maximum exposure values for the radiation work and for the natural radiation as well as the instructions on the monitoring of the exposures are given. Quantities and units for assessing radiation exposure are presented in the appendix of the guide

  10. Three-dimensional wound measurements for monitoring wound healing

    DEFF Research Database (Denmark)

    Bisgaard Jørgensen, Line; Møller Jeppesen, Sune; Halekoh, Ulrich

    Telemedicine is increasingly used for monitoring wound healing. Three-dimensional (3D) measurement methods enable clinicians to assess wound healing with respect to all dimensions. However, the currently available methods are inaccurate, costly or complicated to use. To address these issues, a 3D......-WAM camera was developed. This camera is able to measure wound size (2D area, 3D area, perimeter and volume) and to assess wound characteristics....

  11. Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

    Science.gov (United States)

    Ballesteros, D; Martínez, Ó; Blancas Gómez-Casero, R; Martín Parra, C; López Matamala, B; Estébanez, B; Chana, M

    2015-10-01

    Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. Consecutive patients admitted to the ICU with a diagnosis of distributive shock and the need of insulin infusion for glycemic control were included in the study. These patients were implanted a Continuous Glucose Control Monitoring System (CGMS) with the sensor inserted subcutaneously into the abdominal wall. CGMS values were recorded every 5min. Capillary glucose (CG) was monitored for adjusting insulin perfusion according to the ICU protocol. Correlation between both methods was assessed. A total of 11,673 CGMS and 348 CG values were recorded. In five patients, CGMS failed to detect tissue glucose. A glucose value <3.33mmol/l (<60mg/dl) was observed in 3.6% of CGMS and in 0.29% CG values. 295 pairs of measurements were included in the statistical analysis for correlation assessment. The intraclass correlation coefficient was 0.706. The Pearson correlation coefficient was 0.71 (p<0.0001, 95% CI 0.65-0.76). The mean of differences between both measurement methods was 0.22mmol/l (3.98mg/dl) (95% CI 0.66-7.31). When the Continuous Glucose Control Monitoring System (CGMS) is able to obtain data (75% of the patients), there is correlation between the values obtained by this method and capillary blood glucose in patients with distributive shock. CGMS can detect more episodes of glycemic excursions outside the normal range than intermittent capillary glucose monitoring. Variables that may impair glucose metabolism and peripheral soft tissues perfusion could impair CGMS measurements. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  12. Predictive value of early near-infrared spectroscopy monitoring of patients with traumatic brain injury.

    Science.gov (United States)

    Vilkė, Alina; Bilskienė, Diana; Šaferis, Viktoras; Gedminas, Martynas; Bieliauskaitė, Dalia; Tamašauskas, Arimantas; Macas, Andrius

    2014-01-01

    Traumatic brain injury (TBI) is the leading cause of death and disability in young adults. Study aimed to define the predictive value of early near-infrared spectroscopy (NIRS) monitoring of TBI patients in a Lithuanian clinical setting. Data of 61 patients was analyzed. Predictive value of early NIRS monitoring, computed tomography data and regular intensive care unit (ICU) parameters was investigated. Twenty-six patients expressed clinically severe TBI; 14 patients deceased. Patients who survived expressed higher NIRS values at the periods of admission to operative room (75.4%±9.8% vs. 71.0%±20.5%; P=0.013) and 1h after admission to ICU (74.7%±1.5% vs. 61.9%±19.4%; P=0.029). The NIRS values discriminated hospital mortality groups more accurately than admission GCS score, blood sugar or hemoglobin levels. Admission INR value and NIRS value at 1h after admission to ICU were selected by discriminant analysis into the optimal set of features when classifying hospital mortality groups. Average efficiency of classification using this method was 88.9%. When rsO2 values at 1h after admission to ICU did not exceed 68.0% in the left hemisphere and 68.3% in the right hemisphere, the hazard ratio for death increased by 17.7 times (Pbrain saturation monitoring provides accurate predictive data, which can improve the allocation of scarce medical resources, set the treatment goals and alleviate the early communication with patients' relatives. Copyright © 2014 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  13. Remote state preparation using positive operator-valued measures

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Siendong, E-mail: sdhuang@mail.ndhu.edu.tw [Department of Applied Mathematics, National Dong Hwa University, Hualien 974, Taiwan (China)

    2013-02-04

    We consider the process of remote state preparation using a pure state |ψ〉 with the maximal Schmidt number n. For any given state σ, pure or mixed, a construction of a positive operator-valued measure {M_j}{sub j=0}{sup n} is provided. The classical outcome j=0 indicates the failure of a remote preparation of σ. All other classical outcomes j>0 correspond to unitary transformations of the receiver system such that σ can be prepared. The total probability of successful remote preparation depends on the state σ. Our protocol is a variation of conclusive teleportation and the classical bits required for this protocol are given by log{sub 2}(n+1), which is nearly half that of conclusive teleportation.

  14. An introduction to branching measure-valued processes

    CERN Document Server

    Dynkin, Eugene B

    1994-01-01

    For about half a century, two classes of stochastic processes-Gaussian processes and processes with independent increments-have played an important role in the development of stochastic analysis and its applications. During the last decade, a third class-branching measure-valued (BMV) processes-has also been the subject of much research. A common feature of all three classes is that their finite-dimensional distributions are infinitely divisible, allowing the use of the powerful analytic tool of Laplace (or Fourier) transforms. All three classes, in an infinite-dimensional setting, provide means for study of physical systems with infinitely many degrees of freedom. This is the first monograph devoted to the theory of BMV processes. Dynkin first constructs a large class of BMV processes, called superprocesses, by passing to the limit from branching particle systems. Then he proves that, under certain restrictions, a general BMV process is a superprocess. A special chapter is devoted to the connections between ...

  15. Protocol for fermionic positive-operator-valued measures

    Science.gov (United States)

    Arvidsson-Shukur, D. R. M.; Lepage, H. V.; Owen, E. T.; Ferrus, T.; Barnes, C. H. W.

    2017-11-01

    In this paper we present a protocol for the implementation of a positive-operator-valued measure (POVM) on massive fermionic qubits. We present methods for implementing nondispersive qubit transport, spin rotations, and spin polarizing beam-splitter operations. Our scheme attains linear opticslike control of the spatial extent of the qubits by considering ground-state electrons trapped in the minima of surface acoustic waves in semiconductor heterostructures. Furthermore, we numerically simulate a high-fidelity POVM that carries out Procrustean entanglement distillation in the framework of our scheme, using experimentally realistic potentials. Our protocol can be applied not only to pure ensembles with particle pairs of known identical entanglement, but also to realistic ensembles of particle pairs with a distribution of entanglement entropies. This paper provides an experimentally realizable design for future quantum technologies.

  16. New values of some physical interaction coefficients for dose measurements

    International Nuclear Information System (INIS)

    Eisenlohr, H.H.; Zsdanszky, K.

    1986-01-01

    At its 8th meeting in 1985 Section I of the ''Comite Consultatif pour les Etalons de Mesure des Rayonnements lonisants'' (CCEMRI) to the ''Comite International des Poids et Mesures'' (CIPM) has put forward a recommendation on new values of some physical constants to be used for exposure and absorbed dose determinations (see Annex I). Implementation of this recommendation has some impact on the measurement of exposure, air kerma and absorbed dose, and may result in changes in calibration factors of dosimeters. This subject will be discussed in detail at the IAEA Workshop on Calibration Procedures in Dosimetry, to be held in Quito in October 1986. The following information may assist SSDLs in preparing themselves for the expected changes of calibration factors. The recommendation has been caused by new numerical values of some physical constants which have become available recently. The two most important changes concern: a) S m,a , the ratio of the mean restricted collision mass stopping powers of the chamber material to that of air for electrons crossing the cavity, and b) W air /e, the mean energy required to produce an ion pair in air per electron charge, for electrons emitted by radioactive sources or produced by photon absorption

  17. Measurement results obtained from air quality monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Turzanski, P.K.; Beres, R. [Provincial Inspection of Environmental Protection, Cracow (Poland)

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  18. The use of Tritium measurements for environmental monitoring

    International Nuclear Information System (INIS)

    Camus, H.; Carrere, D; Simeon, C.

    1987-05-01

    Impact studies, compulsory for large installations and land use, require an environmental monitoring program throughout the plant operation. Therefore, and in appliance with the specific regulations concerning them, industrial plants of the nuclear fuel cycle must ensure environmental monitoring including measurements both on the air and water vectors and on the receiving compartments, i.e. food chains and consumers. The development of fine methods in order to assess the limiting capacity of the environment and evaluate the fate of the releases requires to have sensitive bioindicators. For radioactive releases, this is the case of tritium: following the fate of hydrogen, it combines with the vegetal or animal organic molecule, and therefore presents a biological half-life longer than in the elemental water on which measurements were carried out systematically up to now. The interest of measuring organically bound tritium in food chains is presented, and the corresponding technique is described [fr

  19. Measuring the economic value of wildlife: a caution

    Science.gov (United States)

    T. H. Stevens

    1992-01-01

    Wildlife values appear to be very sensitive to whether species are evaluated separately or together, and value estimates often seem inconsistent with neoclassical economic theory. Wildlife value estimates must therefore be used with caution. Additional research about the nature of individual value structures for wildlife is needed.

  20. Indicator values for lichens on Quercus as a tool to monitor ammonia pollution in Denmark

    DEFF Research Database (Denmark)

    Berthelsen, K.; Olsen, H. B.; Søchting, Ulrik

    2008-01-01

    The epiphytic lichen vegetation on solitary Quercus trees was investigated on 13 locations in Denmark in order to test the usability of indicator values to quantify ammonia deposition from the ambient air. Indicator values calculated for each location corresponded well with the expected ecological...... conditions. The indicator values for nitrogenous nutrients significantly correlated with measured nitrogen content in Xanthoria parietina thalli sampled from the investigated Quercus trees. Indicator values for some species are critically evaluated, and it is suggested that indicator values can serve...

  1. Fluorescence Spectroscopy Applied to Monitoring Biodiesel Degradation: Correlation with Acid Value and UV Absorption Analyses.

    Science.gov (United States)

    Vasconcelos, Maydla Dos Santos; Passos, Wilson Espíndola; Lescanos, Caroline Honaiser; Pires de Oliveira, Ivan; Trindade, Magno Aparecido Gonçalves; Caires, Anderson Rodrigues Lima; Muzzi, Rozanna Marques

    2018-01-01

    The techniques used to monitor the quality of the biodiesel are intensely discussed in the literature, partly because of the different oil sources and their intrinsic physicochemical characteristics. This study aimed to monitor the thermal degradation of the fatty acid methyl esters of Sesamum indicum L. and Raphanus sativus L. biodiesels (SILB and RSLB, resp.). The results showed that both biodiesels present a high content of unsaturated fatty acids, ∼84% (SILB) and ∼90% (RSLB). The SILB had a high content of polyunsaturated linoleic fatty acid (18  :  2), about 49%, and the oleic monounsaturated (18  :  1), ∼34%. On the other hand, RSLB presented a considerable content of linolenic fatty acid (18  :  3), ∼11%. The biodiesel samples were thermal degraded at 110°C for 48 hours, and acid value, UV absorption, and fluorescence spectroscopy analysis were carried out. The results revealed that both absorption and fluorescence presented a correlation with acid value as a function of degradation time by monitoring absorptions at 232 and 270 nm as well as the emission at 424 nm. Although the obtained correlation is not completely linear, a direct correlation was observed in both cases, revealing that both properties can be potentially used for monitoring the biodiesel degradation.

  2. Fluorescence Spectroscopy Applied to Monitoring Biodiesel Degradation: Correlation with Acid Value and UV Absorption Analyses

    Directory of Open Access Journals (Sweden)

    Maydla dos Santos Vasconcelos

    2018-01-01

    Full Text Available The techniques used to monitor the quality of the biodiesel are intensely discussed in the literature, partly because of the different oil sources and their intrinsic physicochemical characteristics. This study aimed to monitor the thermal degradation of the fatty acid methyl esters of Sesamum indicum L. and Raphanus sativus L. biodiesels (SILB and RSLB, resp.. The results showed that both biodiesels present a high content of unsaturated fatty acids, ∼84% (SILB and ∼90% (RSLB. The SILB had a high content of polyunsaturated linoleic fatty acid (18  :  2, about 49%, and the oleic monounsaturated (18  :  1, ∼34%. On the other hand, RSLB presented a considerable content of linolenic fatty acid (18  :  3, ∼11%. The biodiesel samples were thermal degraded at 110°C for 48 hours, and acid value, UV absorption, and fluorescence spectroscopy analysis were carried out. The results revealed that both absorption and fluorescence presented a correlation with acid value as a function of degradation time by monitoring absorptions at 232 and 270 nm as well as the emission at 424 nm. Although the obtained correlation is not completely linear, a direct correlation was observed in both cases, revealing that both properties can be potentially used for monitoring the biodiesel degradation.

  3. Blood glucose measurement in patients with suspected diabetic ketoacidosis: a comparison of Abbott MediSense PCx point-of-care meter values to reference laboratory values.

    Science.gov (United States)

    Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope

    2009-04-01

    The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.

  4. On the Value of Monitoring Information for the Structural Integrity and Risk Management

    DEFF Research Database (Denmark)

    Thöns, Sebastian

    2018-01-01

    facilitates the assessment of the value of information associated with SHM. The principal approach for the quantification of the value of SHM is formulated by modeling the fundamental decision of performing SHM or not in conjunction with their expected utilities. The expected utilities are calculated....... The calculation of the expected utilities necessitates a comprehensive and rigorous modeling, which is introduced close to the original formulations and for which analysis characteristics and simplifications are described and derived. The framework provides the basis for the optimization of the structural risk......This article introduces an approach and framework for the quantification of the value of structural health monitoring (SHM) in the context of the structural risk and integrity management for systems.The quantification of the value of SHM builds upon the Bayesian decision and utility theory, which...

  5. The Study and Measurement of Values and Attitudes.

    Science.gov (United States)

    Kerlinger, Fred N.

    The author defines values, attitudes, and beliefs according to their relation to referents. A referent is a construct standing for a set or category of social objects, ideas, or behaviors that is the focus of an attitude. Attitudes and values are belief systems. Beliefs are enduring cognitions about referents; beliefs reflect the value and…

  6. AIP Diffraction measurements using the LHC Beam Loss Monitoring System

    CERN Document Server

    Kalliokoski, Matti

    2017-01-01

    The Beam Loss Monitoring (BLM) system of the Large Hadron Collider protects the machine from beam induced damage by measuring the absorbed dose rates of beam losses, and by triggering beam dump if the rates increase above the allowed threshold limits. Although the detection time scales are optimized for multi-turn losses, information on fast losses can be recovered from the loss data. In this paper, methods in using the BLM system in di ff raction studies are discussed.

  7. Diffraction measurements using the LHC Beam Loss Monitoring System

    Science.gov (United States)

    Kalliokoski, Matti

    2017-03-01

    The Beam Loss Monitoring (BLM) system of the Large Hadron Collider protects the machine from beam induced damage by measuring the absorbed dose rates of beam losses, and by triggering beam dump if the rates increase above the allowed threshold limits. Although the detection time scales are optimized for multi-turn losses, information on fast losses can be recovered from the loss data. In this paper, methods in using the BLM system in diffraction studies are discussed.

  8. Path Planning & Measurement Registration for Robotic Structural Asset Monitoring

    OpenAIRE

    Pierce , Stephen Gareth; Macleod , Charles Norman; Dobie , Gordon; Summan , Rahul

    2014-01-01

    International audience; The move to increased levels of autonomy for robotic delivery of inspection for asset monitoring, demands a structured approach to path planning and measurement data presentation that greatly surpasses the more ad‐,hoc approach typically employed by remotely controlled, but manually driven robotic inspection vehicles. The authors describe a traditional CAD/CAM approach to motion planning (as used in machine tool operation) which has numerous benefits including the...

  9. New parameters and reference values for monitoring iron status in Middle Eastern adolescent male athletes.

    Science.gov (United States)

    Voss, S C; Varamenti, E; Elzain Elgingo, M; Bourdon, P C

    2014-04-01

    Hematological and biochemical parameters of 160 Middle Eastern adolescent male athletes (aged from 12-18 years) were tested in order to investigate their iron status and to establish reference values for this population. A focus of this study was also the investigation of Reticulocyte hemoglobin (RetHe) and soluble transferrin receptor (sTfR). Complete blood count, reticulocyte and sera parameters were analyzed at the beginning of the training season for these adolescent athletes. As the diagnosis of iron deficiency in adolescents is extremely difficult subjects were subdivided in three age groups (12-13, 14-15, 16-18). For most of the parameters our results confirmed the existing reference values reported in young athletes. Exceptions were however found with lower Mean Cell Volumes (79.9±4.3 fl) in this group when compared to other age matched data. RetHe, ferritin and sTfR levels were monitored for the interpretation of the iron status in this population and reference values for these parameters were also established. Information to help evidence based decision making about the need for supplementation or further investigations is provided to physicians and nutritionists. RetHe with a proposed threshold value of 25 pg expands the list of parameters which can be used to monitor athletes.

  10. Measuring and monitoring IT using a balanced scorecard approach.

    Science.gov (United States)

    Gash, Deborah J; Hatton, Todd

    2007-01-01

    Ensuring that the information technology department is aligned with the overall health system strategy and is performing at a consistently high level is a priority at Saint Luke's Health System in Kansas City, Mo. The information technology department of Saint Luke's Health System has been using the balanced scorecard approach described in this article to measure and monitor its performance for four years. This article will review the structure of the IT department's scorecard; the categories and measures used; how benchmarks are determined; how linkage to the organizational scorecard is made; how results are reported; how changes are made to the scorecard; and tips for using a scorecard in other IT departments.

  11. An Analysis of the Relationship between the Perceptions of Value-Added Measurement and Teacher Job Satisfaction

    Science.gov (United States)

    Viar, Meagan Alexis

    2016-01-01

    Educational leaders are struggling with the issue of academic reform as it pertains to accountability for student achievement. With increasing pressures to improve student achievement, many states have adopted value-added measures to monitor student growth and teacher effectiveness. This study undertook a quantitative approach to examine the…

  12. Measurement of an electron-beam size with a beam profile monitor using Fresnel zone plates

    International Nuclear Information System (INIS)

    Iida, K.; Nakamura, N.; Sakai, H.; Shinoe, K.; Takaki, H.; Fujisawa, M.; Hayano, H.; Nomura, M.; Kamiya, Y.; Koseki, T.; Amemiya, Y.; Aoki, N.; Nakayama, K.

    2003-01-01

    We present a non-destructive and real-time beam profile monitor using Fresnel zone plates (FZPs) and the measurement of an electron-beam size with this monitor in the KEK-Accelerator Test Facility (ATF) damping ring. The monitor system has the structure of a long-distance X-ray microscope, where two FZPs constitute an X-ray imaging optics. The synchrotron radiation from the electron beam at the bending magnet is monochromatized by a crystal monochromator and the transverse electron beam image is twenty times magnified by the two FZPs and detected on an X-ray CCD camera. The expected spatial resolution for the selected photon energy of 3.235 keV is sufficiently high to measure the horizontal and vertical beam sizes of the ATF damping ring. With the beam profile monitor, we succeeded in obtaining a clear electron-beam image and measuring the extremely small beam size less than 10 μm. The measured magnification of the X-ray imaging optics in the monitor system was in good agreement with the design value

  13. Crack Growth Monitoring in Harsh Environments by Electric Potential Measurements

    International Nuclear Information System (INIS)

    Lloyd, Wilson Randolph; Reuter, Walter Graham; Weinberg, David Michael

    1999-01-01

    Electric potential measurement (EPM) technology offers an attractive alternative to conventional nondestructive evaluation (NDE) for monitoring crack growth in harsh environments. Where conventional NDE methods typically require localized human interaction, the EPM technique developed at the Idaho National Engineering and Environmental Laboratory (INEEL) can be operated remotely and automatically. Once a crack-like defect is discovered via conventional means, EPM can be applied to monitor local crack size changes. This is of particular interest in situations where an identified structural defect is not immediately rejectable from a fitness-for-service viewpoint, but due to operational and environmental conditions may grow to an unsafe size with continuing operation. If the location is in a harsh environment where periodic monitoring by normal means is either too costly or not possible, a very expensive repair may be immediately mandated. However, the proposed EPM methodology may offer a unique monitoring capability that would allow for continuing service. INEEL has developed this methodology, supporting equipment, and calibration information to apply EPM in a field environment for just this purpose. Laboratory and pilot scale tests on full-size engineering structures (pressure vessels and piping) have been successfully performed. The technique applicable is many severe environments because the sensitive equipment (electronics, operators) can be situated in a remote location, with only current and voltage probe electrical leads entering into the harsh environment. Experimental results showing the utility of the methodology are presented, and unique application concepts that have been examined by multiple experiments are discussed

  14. Gradient heat flux measurement as monitoring method for the diesel engine

    Science.gov (United States)

    Sapozhnikov, S. Z.; Mityakov, V. Yu; Mityakov, A. V.; Vintsarevich, A. V.; Pavlov, A. V.; Nalyotov, I. D.

    2017-11-01

    The usage of gradient heat flux measurement for monitoring of heat flux on combustion chamber surface and optimization of diesel work process is proposed. Heterogeneous gradient heat flux sensors can be used at various regimes for an appreciable length of time. Fuel injection timing is set by the position of the maximum point on the angular heat flux diagram however, the value itself of the heat flux may not be considered. The development of such an approach can be productive for remote monitoring of work process in the cylinders of high-power marine engines.

  15. Measuring breath acetone for monitoring fat loss: Review.

    Science.gov (United States)

    Anderson, Joseph C

    2015-12-01

    Endogenous acetone production is a by-product of the fat metabolism process. Because of its small size, acetone appears in exhaled breath. Historically, endogenous acetone has been measured in exhaled breath to monitor ketosis in healthy and diabetic subjects. Recently, breath acetone concentration (BrAce) has been shown to correlate with the rate of fat loss in healthy individuals. In this review, the measurement of breath acetone in healthy subjects is evaluated for its utility in predicting fat loss and its sensitivity to changes in physiologic parameters. BrAce can range from 1 ppm in healthy non-dieting subjects to 1,250 ppm in diabetic ketoacidosis. A strong correlation exists between increased BrAce and the rate of fat loss. Multiple metabolic and respiratory factors affect the measurement of BrAce. BrAce is most affected by changes in the following factors (in descending order): dietary macronutrient composition, caloric restriction, exercise, pulmonary factors, and other assorted factors that increase fat metabolism or inhibit acetone metabolism. Pulmonary factors affecting acetone exchange in the lung should be controlled to optimize the breath sample for measurement. When biologic factors are controlled, BrAce measurement provides a non-invasive tool for monitoring the rate of fat loss in healthy subjects. © 2015 The Authors Obesity published by Wiley Periodicals, Inc. on behalf of The Obesity Society (TOS).

  16. Anoxic Activated Sludge Monitoring with Combined Nitrate and Titrimetric Measurements

    DEFF Research Database (Denmark)

    Petersen, B.; Gernaey, Krist; Vanrolleghem, P.A.

    2002-01-01

    was with the carbon source in excess, since excess nitrate provoked nitrite build-up thereby complicating the data interpretation. A conceptual model could quantitatively describe the experimental observations and thus link the experimentally measured proton production with the consumption of electron acceptor......An experimental procedure for anoxic activated sludge monitoring with combined nitrate and titrimetric measurements is proposed and evaluated successfully with two known carbon sources, (-)acetate and dextrose. For nitrate measurements an ion-selective nitrate electrode is applied to allow...... for frequent measurements, and thereby the possibility for detailed determination of the denitrification biokinetics. An internal nitrate electrode calibration is implemented in the experiments to avoid the often-encountered electrode drift problem. It was observed that the best experimental design...

  17. Biodiesel transesterification kinetics monitored by pH measurement.

    Science.gov (United States)

    Clark, William M; Medeiros, Nicholas J; Boyd, Donal J; Snell, Jared R

    2013-05-01

    Quantification of a pH change that was observed over the course of the transesterification reaction that converts vegetable oil to biodiesel may provide a simple method to monitor the reaction. Transesterification of canola oil at 6:1 methanol to oil ratio with 0.5 wt.% KOH as catalyst was studied at 25, 35, and 45 °C. Reaction conversion was correlated to pH measurements and the results were shown to be in agreement with an independent measure of conversion using an enzymatic assay for glycerol. Rate constants obtained from these measurements are consistent with those in the literature. The measured pH change appears to be related to dilution of OH(-) ions as the oil is converted to products rather than to depletion of OH(-) due to reaction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. The effect of bank monitoring as an alternative of corporate governance mechanisms on the borrowers’ firm value: Evidence from Indonesian listed firms

    Directory of Open Access Journals (Sweden)

    Alexandra Ryan Ahmad Dina

    2012-12-01

    Full Text Available The objective of this research is to examine the effect of bank monitoring as an alternative of corporate governance mechanisms on the borrowers’ firm value. The strengths of bank monitoring on the borrowers are measured based on the magnitude of the bank loan, the size of the loan from banks with high monitoring quality, the length of a bank loan outstanding period, and the number of lenders. The research hypotheses were tested using multiple regression model with a sample of 230 companies listed in Indonesia Stock Exchange during 2009. The empirical results show that only the size of the loan from banks with high monitoring quality and the number of lenders significantly influences the borrowers’ firm value. These findings imply that only banks with high monitoring quality could play an important role in the corporate governance and therefore increasing the firm value by their monitoring function. Furthermore, bank monitoring is less effective if a company borrows from many banks, and therefore decreasing the firm value

  19. A method for valuing architecture-based business transformation and measuring the value of solutions architecture

    NARCIS (Netherlands)

    Slot, R.G.

    2010-01-01

    Enterprise and Solution Architecture are key in today’s business environment. It is surprising that the foundation and business case for these activities are nonexistent; the financial value for the business of these activities is largely undetermined. To determine business value of enterprise and

  20. Calibration of Heat Stress Monitor and its Measurement Uncertainty

    Science.gov (United States)

    Ekici, Can

    2017-07-01

    Wet-bulb globe temperature (WBGT) equation is a heat stress index that gives information for the workers in the industrial areas. WBGT equation is described in ISO Standard 7243 (ISO 7243 in Hot environments—estimation of the heat stress on working man, based on the WBGT index, ISO, Geneva, 1982). WBGT is the result of the combined quantitative effects of the natural wet-bulb temperature, dry-bulb temperature, and air temperature. WBGT is a calculated parameter. WBGT uses input estimates, and heat stress monitor measures these quantities. In this study, the calibration method of a heat stress monitor is described, and the model function for measurement uncertainty is given. Sensitivity coefficients were derived according to GUM. Two-pressure humidity generators were used to generate a controlled environment. Heat stress monitor was calibrated inside of the generator. Two-pressure humidity generator, which is located in Turkish Standard Institution, was used as the reference device. This device is traceable to national standards. Two-pressure humidity generator includes reference temperature Pt-100 sensors. The reference sensor was sheltered with a wet wick for the calibration of natural wet-bulb thermometer. The reference sensor was centred into a black globe that has got 150 mm diameter for the calibration of the black globe thermometer.

  1. Monitoring of thiopurine metabolites in patients with inflammatory bowel disease-what is actually measured?

    Science.gov (United States)

    Vikingsson, Svante; Carlsson, Björn; Almer, Sven H C; Peterson, Curt

    2009-06-01

    Azathioprine and 6-mercaptopurine are often used in the treatment of patients with inflammatory bowel disease (IBD). They are prodrugs and undergo a complex metabolism to active and inactive metabolites. Thiopurine treatment is monitored in many laboratories by measuring metabolite concentrations in erythrocytes (red blood cells). The metabolites of interest are not measured directly but as hydrolysis products, which can be produced from several metabolites. The aim of this study was to examine which metabolites are actually measured during routine monitoring. Samples from 18 patients treated with a thiopurine were analyzed by a typical routine high-performance liquid chromatography method for therapeutic drug monitoring and by a newly developed specific method measuring thioguanosine monophosphate (TGMP), thioguanosine diphosphate (TGDP), and thioguanosine triphosphate (TGTP), as well as methylthioinosine monophosphate (meTIMP), and the results were compared. 6-Thioguanine nucleotide (TGN) values detected by the routine method were 69% (range 40%-90%) of the sum of TGMP, TGDP, and TGTP measured by the specific method. TGTP and TGDP contributed 85% (range 78%-90%) and 14% (range 10%-21%) of the TGN total, respectively. Thioguanosine was not found in any patient sample. The concentration of meTIMP obtained by the routine method was 548% of the value obtained by the specific method (range 340%-718%). The difference in TGN measurements between the routine and specific methods can be explained by low hydrolysis efficiency in the routine method, although the most likely explanation for the difference in meTIMP values is that not yet identified metabolites are codetermined in the routine high-performance liquid chromatography method. Concentrations reported as TGN during therapeutic drug monitoring of thiopurine metabolites consist of TGDP and TGTP with a minor contribution of the TGMP. Concentrations reported as meTIMP or methyl mercaptopurine consist in part of me

  2. Reportable Creation: value, performance and risk measurement in financial reporting

    NARCIS (Netherlands)

    N.G. de Jager

    2006-01-01

    textabstractReporting on value or reporting value-relevant information unavoidably implies that estimates of future cash flows should be made. Consequently, uncertainty becomes an important factor in (external) financial reporting. For a long time, uncertainty was dealt with by substituting relevant

  3. Measuring Strategic Value-Drivers for Managing Intellectual Capital

    Science.gov (United States)

    Bose, S.; Oh, K. B.

    2004-01-01

    In an evolving business environment characterised by globalisation and a challenging competitive paradigm, it is imperative for strategic management processes to focus on the financial perspectives of value and risk in intellectual capital to create sustainability in long-term value. This paper presents the key issues pertaining to the strategic…

  4. Measuring the added value of IT in construction firms

    NARCIS (Netherlands)

    Laan, Albertus; Voordijk, Johannes T.; Kolkman, S.; Greenwood, D.J.

    2003-01-01

    The added value of information technology (IT) varies widely along firms. The objective of this paper is to analyse the underlying factors that enlarge or reduce the added value of information systems and IT-applications in construction firms. By applying the process-oriented approach of Tallon et

  5. Value of information in sequential decision making: Component inspection, permanent monitoring and system-level scheduling

    International Nuclear Information System (INIS)

    Memarzadeh, Milad; Pozzi, Matteo

    2016-01-01

    We illustrate how to assess the Value of Information (VoI) in sequential decision making problems modeled by Partially Observable Markov Decision Processes (POMDPs). POMDPs provide a general framework for modeling the management of infrastructure components, including operation and maintenance, when only partial or noisy observations are available; VoI is a key concept for selecting explorative actions, with application to component inspection and monitoring. Furthermore, component-level VoI can serve as an effective heuristic for assigning priorities to system-level inspection scheduling. We introduce two alternative models for the availability of information, and derive the VoI in each of those settings: the Stochastic Allocation (SA) model assumes that observations are collected with a given probability, while the Fee-based Allocation model (FA) assumes that they are available at a given cost. After presenting these models at component-level, we investigate how they perform for system-level inspection scheduling. - Highlights: • On the Value of Information in POMDPs, for optimal exploration of systems. • A method for assessing the Value of Information of permanent monitoring. • A method for allocating inspections in systems made up by parallel POMDPs.

  6. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  7. Flood effects on an Alaskan stream restoration project: the value of long-term monitoring

    Science.gov (United States)

    Densmore, Roseann V.; Karle, Kenneth F.

    2009-01-01

    On a nationwide basis, few stream restoration projects have long-term programs in place to monitor the effects of floods on channel and floodplain configuration and floodplain vegetation, but long-term and event-based monitoring is required to measure the effects of these stochastic events and to use the knowledge for adaptive management and the design of future projects. This paper describes a long-term monitoring effort (15 years) on a stream restoration project in Glen Creek in Denali National Park and Preserve in Alaska. The stream channel and floodplain of Glen Creek had been severely degraded over a period of 80 years by placer mining for gold, which left many reaches with unstable and incised streambeds without functioning vegetated floodplains. The objectives of the original project, initiated in 1991, were to develop and test methods for the hydraulic design of channel and floodplain morphology and for floodplain stabilization and riparian habitat recovery, and to conduct research and monitoring to provide information for future projects in similar degraded watersheds. Monitoring methods included surveyed stream cross-sections, vegetation plots, and aerial, ground, and satellite photos. In this paper we address the immediate and outlying effects of a 25-year flood on the stream and floodplain geometry and riparian vegetation. The long-term monitoring revealed that significant channel widening occurred following the flood, likely caused by excessive upstream sediment loading and the fairly slow development of floodplain vegetation in this climate. Our results illustrated design flaws, particularly in regard to identification and analysis of sediment sources and the dominant processes of channel adjustment.

  8. Continuous monitoring systems for indoor radon measurement: construction and results of their testing

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.; Bujnova, A.; Polaskova, A.; Hola, O.

    2007-01-01

    Two continuous radon monitoring systems were built on the basis of the scintillation chambers. The first system used the large volume scintillation chamber with the volume of 4.5 liters and the second one the commercial scintillation chamber with the volume of 1 liter as the detectors for radon concentration measurement. Both systems were calibrated by Ward-Borak method. The detection limits of monitoring systems are 2.9 Bq · m -3 and 5.1 Bq · m -3 respectively, at -2 hour counting period and 30 % statistical uncertainty. The radon monitoring systems and the professional radon monitor AlphaGUARD were tested in real conditions of working room. The testing showed that long-tenn courses of radon activity concentrations obtained by all three monitors are highly correlated (R 2 ∼0.95). Also the average values of radon activity concentrations calculated on the basis of measured data are identical in the scope of counting errors already at the measurement of the radon activity concentrations in the range of (10-120) Bq · m -3 . (authors)

  9. Value of information: A roadmap to quantifying the benefit of structural health monitoring

    DEFF Research Database (Denmark)

    Straub, D.; Chatzi, E.; Bismut, E.

    2017-01-01

    The concept of value of information (VoI) enables quantification of the benefits provided by structural health monitoring (SHM) systems – in principle. Its implementation is challenging, as it requires an explicit modelling of the structural system’s life cycle, in particular of the decisions...... that are taken based on the SHM information. In this paper, we approach the VoI analysis through an influence diagram (ID), which supports the modelling process. We provide a simple example for illustration and discuss challenges associated with real-life implementation....

  10. Real time alpha value measurement with Feynman-α method utilizing time series data acquisition on low enriched uranium system

    International Nuclear Information System (INIS)

    Tonoike, Kotaro; Yamamoto, Toshihiro; Watanabe, Shoichi; Miyoshi, Yoshinori

    2003-01-01

    As a part of the development of a subcriticality monitoring system, a system which has a time series data acquisition function of detector signals and a real time evaluation function of alpha value with the Feynman-alpha method was established, with which the kinetic parameter (alpha value) was measured at the STACY heterogeneous core. The Hashimoto's difference filter was implemented in the system, which enables the measurement at a critical condition. The measurement result of the new system agreed with the pulsed neutron method. (author)

  11. Beam based measurement of beam position monitor electrode gains

    Directory of Open Access Journals (Sweden)

    D. L. Rubin

    2010-09-01

    Full Text Available Low emittance tuning at the Cornell Electron Storage Ring (CESR test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ∼0.1%.

  12. Beam based measurement of beam position monitor electrode gains

    Science.gov (United States)

    Rubin, D. L.; Billing, M.; Meller, R.; Palmer, M.; Rendina, M.; Rider, N.; Sagan, D.; Shanks, J.; Strohman, C.

    2010-09-01

    Low emittance tuning at the Cornell Electron Storage Ring (CESR) test accelerator depends on precision measurement of vertical dispersion and transverse coupling. The CESR beam position monitors (BPMs) consist of four button electrodes, instrumented with electronics that allow acquisition of turn-by-turn data. The response to the beam will vary among the four electrodes due to differences in electronic gain and/or misalignment. This variation in the response of the BPM electrodes will couple real horizontal offset to apparent vertical position, and introduce spurious measurements of coupling and vertical dispersion. To alleviate this systematic effect, a beam based technique to measure the relative response of the four electrodes has been developed. With typical CESR parameters, simulations show that turn-by-turn BPM data can be used to determine electrode gains to within ˜0.1%.

  13. On the Value of Structural Health Monitoring Information for the Operation of Wind Parks

    DEFF Research Database (Denmark)

    Thöns, Sebastian; Faber, Michael H.; Val, Dimitri V.

    2017-01-01

    wind turbine systems and its components is developed accounting for the wind park functionality, i.e. power production, its operation and its cascading damage and failure scenarios. This system model facilitates to quantify the expected benefits and risks throughout the service life accounting......In the present paper, an approach for the quantification of the Value of Structural Health Monitoring (SHM) Information building upon a framework for infrastructure system utility and decision analysis is developed and applied to the operation of wind parks. The quantification of the value of SHM...... facilitates a benefit and risk informed assessment and optimization of SHM strategies and encompasses models for the infrastructure functionality, the structural constituent and system risks and its management as well as the performance of SHM strategies. A wind park system model incorporating the structural...

  14. Extreme dissolved oxygen variability in urbanised tropical wetlands: The need for detailed monitoring to protect nursery ground values

    Science.gov (United States)

    Dubuc, Alexia; Waltham, Nathan; Malerba, Martino; Sheaves, Marcus

    2017-11-01

    Little is known about levels of dissolved oxygen fish are exposed to daily in typical urbanised tropical wetlands found along the Great Barrier Reef coastline. This study investigates diel dissolved oxygen (DO) dynamics in one of these typical urbanised wetlands, in tropical North Queensland, Australia. High frequency data loggers (DO, temperature, depth) were deployed for several days over the summer months in different tidal pools and channels that fish use as temporal or permanent refuges. DO was extremely variable over a 24 h cycle, and across the small-scale wetland. The high spatial and temporal DO variability measured was affected by time of day and tidal factors, namely water depth, tidal range and tidal direction (flood vs ebb). For the duration of the logging time, DO was mainly above the adopted threshold for hypoxia (50% saturation), however, for around 11% of the time, and on almost every logging day, DO values fell below the threshold, including a severe hypoxic event (nursery ground value. There is a substantial discontinuity between the recommended DO values in the Australian and New Zealand Guidelines for Fresh and Marine Water Quality and the values observed in this wetland, highlighting the limited value of these guidelines for management purposes. Local and regional high frequency data monitoring programs, in conjunction with local exposure risk studies are needed to underpin the development of the management that will ensure the sustainability of coastal wetlands.

  15. What is the value of ultrasound soft tissue measurements in the prediction of abnormal fetal growth?

    LENUS (Irish Health Repository)

    Farah, N

    2012-02-01

    Abnormal fetal growth increases the complications of pregnancy not only for the baby but also for the mother. Growth abnormalities also have lifelong consequences. These babies are at increased risk of insulin resistance, diabetes and hypertension later in life. It is important to identify these babies antenatally to optimise their clinical care. Although used extensively antenatally to monitor fetal growth, ultrasound has its limitations. Despite the use of more than 50 different formulae to estimate fetal weight, their performance has been poor at the extremes of fetal weight. Over the past 20 years there has been emerging interest in studying fetal soft tissue measurements to improve detection of growth abnormalities. This review paper outlines the value of soft tissue measurements in identifying fetal growth abnormalities, in estimating fetal weight and in managing diabetes mellitus in pregnancy.

  16. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn; Hempel, Maria; Henschel, Hans; Karacheban, Olena; Lange, Wolfgang; Lohmann, Wolfgang; Novgorodova, Olga; Penno, Marek; Walsh, Roberval; Dabrowski, Anne; Guthoff, Moritz; Loos, R; Ryjov, Vladimir; Burtowy, Piotr; Lokhovitskiy, Arkady; Odell, Nathaniel; Przyborowski, Dominik; Stickland, David P; Zagozdzinska, Agnieszka

    2014-01-01

    The CMS beam condition monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be discussed, including results from the January 201...

  17. Upgraded Fast Beam Conditions Monitor for CMS online luminosity measurement

    CERN Document Server

    Leonard, Jessica Lynn

    2014-01-01

    The CMS beam and radiation monitoring subsystem BCM1F during LHC Run I consisted of 8 individual diamond sensors situated around the beam pipe within the tracker detector volume, for the purpose of fast monitoring of beam background and collision products. Effort is ongoing to develop the use of BCM1F as an online bunch-by-bunch luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. To prepare for the expected increase in the LHC luminosity and the change from 50 ns to 25 ns bunch separation, several changes to the system are required, including a higher number of sensors and upgraded electronics. In particular, a new real-time digitizer with large memory was developed and is being integrated into a multi-subsystem framework for luminosity measurement. Current results from Run II preparation will be shown, including results from the January 201...

  18. On the method of estimating the event of unusually high values in the radiation monitoring data

    International Nuclear Information System (INIS)

    Kumazawa, Shigeru; Matsui, Hiroshi

    1980-01-01

    The method was discussed for estimating a comparatively rare occurrence of monitoring data much greater than the average in the field of radiation protection. The features of and the mutual relationships among four types of probability distributions, i.e., normal, log-normal, double-exponential and log-double-exponential, were presented, and their application to various monitoring data of radiation protection was shown. For graphical analysis of empirical distributions the followings were concluded: 1. The upper probabilities are considerably affected by the method of calculating the quantiles and the method of logarithmic transformation of a stochastic variable after a fixed value being added to or subtracted from it to obtain the better straight-line fit on the probability paper. 2. A double-exponential distribution provided a good fit to the annual dose maxima, while a log-double-exponential distribution did to the radioactive contamination maxima in a fixed period of time or in a fixed region of space. 3. The monitoring data arranged in the order of their magnitude were expressed by an exponential function of the order for dose data and by a power function of the order for radioactive contamination data. (author)

  19. Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.

    Science.gov (United States)

    Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E

    2013-09-25

    The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men

  20. Measuring the value of older people's production: a diary study

    Directory of Open Access Journals (Sweden)

    Sahlen Klas-Göran

    2012-01-01

    Full Text Available Abstract Background The productive capacity of retired people is usually not valued. However, some retirees produce much more than we might expect. This diary-based study identifies the activities of older people, and suggests some value mechanisms. One question raised is whether it is possible to scale up this diary study into a larger representative study. Methods Diaries kept for one week were collected among 23 older people in the north of Sweden. The texts were analysed with a grounded theory approach; an interplay between ideas and empirical data. Results Some productive activities of older people must be valued as the opportunity cost of time or according to the market value, and others must be valued with the replacement cost. In order to make the choice between these methods, it is important to consider the societal entitlement. When there is no societal entitlement, the first or second method must be used; and when it exists, the third must be used. Conclusions An explicit investigation of the content of the entitlement is needed to justify the choice of valuation method for each activity. In a questionnaire addressing older people's production, each question must be adjusted to the type of production. In order to fully understand this production, it is important to consider the degree of free choice to conduct an activity, as well as health-related quality of life.

  1. Airborne anthropogenic radioactivity measurements from an international radionuclide monitoring system

    International Nuclear Information System (INIS)

    Mason, L.R.; Bohner, J.D.; Williams, D.L.

    1998-01-01

    Anthropogenic radioactivity is being measured in near-real time by an international monitoring system designed to verify the Comprehensive Nuclear Test Ban Treaty. Airborne radioactivity measurements are conducted in-situ by stations that are linked to a central data processing and analysis facility. Aerosols are separated by high-volume air sampling with high-efficiency particulate filters. Radio-xenon is separated from other gases through cryogenic methods. Gamma-spectrometry is performed by high purity germanium detectors and the raw spectral data is immediately transmitted to the central facility via Internet, satellite, or modem. These highly sensitive sensors, combined with the automated data processing at the central facility, result in a system capable of measuring environmental radioactivity on the microbecquerel scale where the data is available to scientists within minutes of the field measurement. During the past year, anthropogenic radioactivity has been measured at approximately half of the stations in the current network. Sources of these measured radionuclides include nuclear power plant emissions, Chernobyl resuspension, and isotope production facilities. The ability to thoroughly characterize site-specific radionuclides, which contribute to the radioactivity of the ambient environment, will be necessary to reduce the number of false positive events. This is especially true of anthropogenic radionuclides that could lead to ambiguous analysis. (author)

  2. Whole body measurements for in vivo monitoring in emergency situations

    International Nuclear Information System (INIS)

    Doerfel, H.

    2000-01-01

    The conventional procedures for in vivo monitoring of γ-emitting radionuclides require a lot of information, such as time and pathway of intake, physical and chemical form of incorporated materials, metabolism etc. In emergency situations this information is rarely available, thus resulting in significant uncertainties for the estimation of intake and committed dose equivalent. Moreover, the procedure is time consuming and thus only a relatively small number of persons can be monitored. In order to cope with these difficulties, a new method for direct internal dosimetry has recently been developed at Karlsruhe Nuclear Research Centre. The method is based on the measurement of the integral photon flux emitted from the body using a special detector system which has been optimised in such a way that the system sensitivity matches the respective dose factors for a maximum number of radionuclides and deposition sites in the body. The detector system consists of four plastic scintillation detectors, which are positioned at the thyroid, at the lungs, under the gastro-intestinal tract and over the thighs of the person monitored in a seated posture. The system allows for detection of effective dose equivalent rates down to 1.6 μSv/week, the mean detection uncertainty being about 200% for known radionuclide mixtures and about 600% for unknown radionuclide mixtures, respectively. The detector system is very easy to handle; the measurement can be performed by untrained individuals and the results are available after a very short measuring time (20 s). Thus, the detector system is appropriate especially for short-term decision making after incidents or accidents. Because of its relative low weight (1 t) the detector system could be installed as a mobile unit in a container for transportation by car, train or aircraft. Thus, in emergency situations the detector system can be brought to the site within a short period of time. It allows for the rapid monitoring of a large number

  3. Attitudes toward statistics in medical postgraduates: measuring, evaluating and monitoring.

    Science.gov (United States)

    Zhang, Yuhai; Shang, Lei; Wang, Rui; Zhao, Qinbo; Li, Chanjuan; Xu, Yongyong; Su, Haixia

    2012-11-23

    In medical training, statistics is considered a very difficult course to learn and teach. Current studies have found that students' attitudes toward statistics can influence their learning process. Measuring, evaluating and monitoring the changes of students' attitudes toward statistics are important. Few studies have focused on the attitudes of postgraduates, especially medical postgraduates. Our purpose was to understand current attitudes regarding statistics held by medical postgraduates and explore their effects on students' achievement. We also wanted to explore the influencing factors and the sources of these attitudes and monitor their changes after a systematic statistics course. A total of 539 medical postgraduates enrolled in a systematic statistics course completed the pre-form of the Survey of Attitudes Toward Statistics -28 scale, and 83 postgraduates were selected randomly from among them to complete the post-form scale after the course. Most medical postgraduates held positive attitudes toward statistics, but they thought statistics was a very difficult subject. The attitudes mainly came from experiences in a former statistical or mathematical class. Age, level of statistical education, research experience, specialty and mathematics basis may influence postgraduate attitudes toward statistics. There were significant positive correlations between course achievement and attitudes toward statistics. In general, student attitudes showed negative changes after completing a statistics course. The importance of student attitudes toward statistics must be recognized in medical postgraduate training. To make sure all students have a positive learning environment, statistics teachers should measure their students' attitudes and monitor their change of status during a course. Some necessary assistance should be offered for those students who develop negative attitudes.

  4. Attitudes toward statistics in medical postgraduates: measuring, evaluating and monitoring

    Science.gov (United States)

    2012-01-01

    Background In medical training, statistics is considered a very difficult course to learn and teach. Current studies have found that students’ attitudes toward statistics can influence their learning process. Measuring, evaluating and monitoring the changes of students’ attitudes toward statistics are important. Few studies have focused on the attitudes of postgraduates, especially medical postgraduates. Our purpose was to understand current attitudes regarding statistics held by medical postgraduates and explore their effects on students’ achievement. We also wanted to explore the influencing factors and the sources of these attitudes and monitor their changes after a systematic statistics course. Methods A total of 539 medical postgraduates enrolled in a systematic statistics course completed the pre-form of the Survey of Attitudes Toward Statistics −28 scale, and 83 postgraduates were selected randomly from among them to complete the post-form scale after the course. Results Most medical postgraduates held positive attitudes toward statistics, but they thought statistics was a very difficult subject. The attitudes mainly came from experiences in a former statistical or mathematical class. Age, level of statistical education, research experience, specialty and mathematics basis may influence postgraduate attitudes toward statistics. There were significant positive correlations between course achievement and attitudes toward statistics. In general, student attitudes showed negative changes after completing a statistics course. Conclusions The importance of student attitudes toward statistics must be recognized in medical postgraduate training. To make sure all students have a positive learning environment, statistics teachers should measure their students’ attitudes and monitor their change of status during a course. Some necessary assistance should be offered for those students who develop negative attitudes. PMID:23173770

  5. Measuring the Economic Value of Pre-MBA Work Experience

    Science.gov (United States)

    Yeaple, Ronald N.; Johnston, Mark W.; Whittingham, Keith L.

    2010-01-01

    Pre-MBA work experience is required for admission to many graduate schools of business. In the present study, MBA graduates with a wide range of pre-MBA work experience were surveyed to assess the economic value of such work experience. No evidence was found of a systematic financial advantage to students from working for several years before…

  6. SOLUTIONS FOR MEASURING THE FAIR VALUE OF THE WORKFORCE

    Directory of Open Access Journals (Sweden)

    Deaconu Adela

    2009-05-01

    Full Text Available For the past decades International Accounting Standards and other Anglo-Saxon standards, for example the American ones, had promoted fair value as a valuation basis for the elements of the financial statements. Thus, the quality of the financial informati

  7. Measuring the Multinational Business Value – An indexing Approach

    Directory of Open Access Journals (Sweden)

    Jorge MONGAY HURTADO

    2018-03-01

    Full Text Available The research project aims to present a comparative analysis of countries related to the value of their MNCs in the global arena. The study works in secondary data analysis using as a platform the Forbes Global 2000 list, which is maybe the best source explaining the presence of MNCs by country. This research goes beyond the information provided by the original list, offering an index and information about the number of corporations per country as well as their value (number of corpora-tions per country, their position in the ranking and the weight obtained by each company expressed in numerical value. Also the index obtained has been adjusted to the population of each country to determine which one should be the expected value per country from a more realistic perspective. An analysis of cultural clus-ters and trading zones has been applied as well. Finally, a calculation of the dif-ferent sectors where MNCs operate give the index the possibility to estimate the % of penetration or importance of the services and financial sector in each country and in the world.

  8. Agreement Between Home-Based Measurement of Stool Calprotectin and ELISA Results for Monitoring Inflammatory Bowel Disease Activity

    NARCIS (Netherlands)

    Heida, Anke; Knol, Mariska; Kobold, Anneke Muller; Bootsman, Josette; Dijkstra, Gerard; van Rheenen, Patrick F

    2017-01-01

    BACKGROUND & AIMS: An increasing number of physicians use repeated measurements of stool calprotectin to monitor intestinal inflammation in patients with inflammatory bowel diseases (IBDs). A lateral flow-based rapid test allows patients to measure their own stool calprotectin values at home. The

  9. Automatic measurement for monitoring crack growth with electric potential technique

    International Nuclear Information System (INIS)

    Nakajima, Nobuya; Kikuchi, Masaaki; Shima, Seishi

    1981-10-01

    In the study of fracture mechanics, it is one of the most important problems to monitor the crack growth phenomena. Recently, many experimental methods have been developed. In this report, the Direct Current (DC) potential method is employed for measuring the crack growth length in the pressuried high temperature water. The objective of the current investigation is to develop an experimental method to quantify the sensitivity of this method in the air environment using the Compact Tension (CT) specimen. The main results obtained are as follows: 1) It is ignored that the electrical potential changes with plastic deformation at the crack tip of the specimen. 2) Using the Reversible Direct Current (RDC) Method, the measurement system gives no effect on the electrical stability for a long time. 3) For the fatigue and statical crack growth length, good relation is observed between the crack length-to-specimen width ratio (a/W) and potential ratio (Va/Vo). (author)

  10. Unrestricted release measurements with ambient air ionization monitors

    International Nuclear Information System (INIS)

    MacArthur, D.; Gunn, R.; Dockray, T.; Luff, C.

    1999-01-01

    Radiation monitoring systems based on the long-range alpha detection (LRAD) technique, such as the BNFL Instruments IonSens trademark, provide a single contamination measurement for an entire object rather than the more familiar individual readings for smaller surface areas. The LRAD technique relies on the ionization of ambient air molecules by alpha particles, and the subsequent detection of these ions, rather than direct detection of the alpha particles themselves. A single monitor can detect all of the ions produced over a large object and report a total contamination level for the entire surface of that object. However, both the unrestricted release limits specified in USDOE Order 5400.5 (and similar documents in other countries), and the definitions of radioactive waste categories, are stated in terms of contamination per area. Thus, conversion is required between the total effective contamination as measured by the LRAD-based detector and the allowable release limits. In addition, since the release limits were not written assuming an averaging detector system, the method chosen to average the assumed contamination over the object can have a significant impact on the effective sensitivity of the detector

  11. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  12. CENTIMETER COSMO-SKYMED RANGE MEASUREMENTS FOR MONITORING GROUND DISPLACEMENTS

    Directory of Open Access Journals (Sweden)

    F. Fratarcangeli

    2016-06-01

    Full Text Available The SAR (Synthetic Aperture Radar imagery are widely used in order to monitor displacements impacting the Earth surface and infrastructures. The main remote sensing technique to extract sub-centimeter information from SAR imagery is the Differential SAR Interferometry (DInSAR, based on the phase information only. However, it is well known that DInSAR technique may suffer for lack of coherence among the considered stack of images. New Earth observation SAR satellite sensors, as COSMO-SkyMed, TerraSAR-X, and the coming PAZ, can acquire imagery with high amplitude resolutions too, up to few decimeters. Thanks to this feature, and to the on board dual frequency GPS receivers, allowing orbits determination with an accuracy at few centimetres level, the it was proven by different groups that TerraSAR-X imagery offer the capability to achieve, in a global reference frame, 3D positioning accuracies in the decimeter range and even better just exploiting the slant-range measurements coming from the amplitude information, provided proper corrections of all the involved geophysical phenomena are carefully applied. The core of this work is to test this methodology on COSMO-SkyMed data acquired over the Corvara area (Bolzano – Northern Italy, where, currently, a landslide with relevant yearly displacements, up to decimeters, is monitored, using GPS survey and DInSAR technique. The leading idea is to measure the distance between the satellite and a well identifiable natural or artificial Persistent Scatterer (PS, taking in account the signal propagation delays through the troposphere and ionosphere and filtering out the known geophysical effects that induce periodic and secular ground displacements. The preliminary results here presented and discussed indicate that COSMO-SkyMed Himage imagery appear able to guarantee a displacements monitoring with an accuracy of few centimetres using only the amplitude data, provided few (at least one stable PS’s are

  13. Monitoring catalyst flow rate in a FCC cold pilot unity by gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Brito, Marcio F.P.; Netto, Wilson F.S.; Miranda, Marcia V.F.E.S.; Junior, Isacc A.S.; Dantas, Carlos C.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    A model for monitoring catalyst mass flow in riser of Fluid Catalytic Cracking - FCC, pilot unity as a function of air flow and solid injection is proposed. The fluidized FCC- catalyst bed system is investigated in an experimental setup the Cold Pilot Unity - CPU by means of gamma ray transmission measurements. Riser in CPU simulates the reactor in FCC process. By automation control air flow is instrumentally measured in riser and the solid injection is manually controlled by valve adjusting. Keeping a constant solid injection, catalyst level at the return column was measured by gamma transmission for several air flow values in riser. The operational condition reached a steady state regime before given to setup a new air flow value. A calibration of catalyst level as a function of air flow in riser is calculated, therefore, a model for solid feed rate is derived. Recent published work evaluates solid concentration in riser of the CPU by means of gamma ray transmission, and a correlation with air velocity is obtained. In this work, the model for solid feed rate was further investigated by carrying out experiments to measure catalyst concentration at the same air flow values. These experiments lead to a model for monitoring catalyst flow in riser as function of solid feed rate and air flow. Simulation with random numbers produced with Matlab software allows to define validation criteria for the model parameters. (author)

  14. Different top-down approaches to estimate measurement uncertainty of whole blood tacrolimus mass concentration values.

    Science.gov (United States)

    Rigo-Bonnin, Raül; Blanco-Font, Aurora; Canalias, Francesca

    2018-05-08

    Values of mass concentration of tacrolimus in whole blood are commonly used by the clinicians for monitoring the status of a transplant patient and for checking whether the administered dose of tacrolimus is effective. So, clinical laboratories must provide results as accurately as possible. Measurement uncertainty can allow ensuring reliability of these results. The aim of this study was to estimate measurement uncertainty of whole blood mass concentration tacrolimus values obtained by UHPLC-MS/MS using two top-down approaches: the single laboratory validation approach and the proficiency testing approach. For the single laboratory validation approach, we estimated the uncertainties associated to the intermediate imprecision (using long-term internal quality control data) and the bias (utilizing a certified reference material). Next, we combined them together with the uncertainties related to the calibrators-assigned values to obtain a combined uncertainty for, finally, to calculate the expanded uncertainty. For the proficiency testing approach, the uncertainty was estimated in a similar way that the single laboratory validation approach but considering data from internal and external quality control schemes to estimate the uncertainty related to the bias. The estimated expanded uncertainty for single laboratory validation, proficiency testing using internal and external quality control schemes were 11.8%, 13.2%, and 13.0%, respectively. After performing the two top-down approaches, we observed that their uncertainty results were quite similar. This fact would confirm that either two approaches could be used to estimate the measurement uncertainty of whole blood mass concentration tacrolimus values in clinical laboratories. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry

    NARCIS (Netherlands)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H.; Tol, Johannes L.; Verhaar, Jan A. N.; Weir, Adam

    2016-01-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of

  16. Fluid flow measurements by means of vibration monitoring

    International Nuclear Information System (INIS)

    Campagna, Mauro M; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano

    2015-01-01

    The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology. (paper)

  17. Fluid flow measurements by means of vibration monitoring

    Science.gov (United States)

    Campagna, Mauro M.; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano

    2015-11-01

    The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology.

  18. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    International Nuclear Information System (INIS)

    William S. Charlton

    1999-01-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels

  19. Technical Challenge and Demonstration of Advanced Solution Monitoring and Measurement System (ASMS)

    International Nuclear Information System (INIS)

    Takaya, A.; Mukai, Y.; Nakamura, H.; Hosoma, T.; Yoshimoto, K.; Tamura, T.; Iwamoto, T.

    2010-01-01

    JNFL and JAEA have collaboratively started to develop an Advanced Solution Measurement and monitoring System (ASMS) as a part of technical challenge intended for next generation safeguards NDA equipment. After we completed feasibility study by using small detectors, the second stage of ASMS has installed into PCDF tank located in a cell, and then tested and calibrated by Pu nitrate solution experimentally. There was no experience measuring around 50kg Pu inventory directly, so it was very challenging work. The conventional SMMS (Solution Monitoring and Measurement System) that is composed of precision manometers acquires density, level and temperature of solution, so that the sampling and analysis are essential to obtain the nuclear material amount in the tank. The SMMS has two weak points on verification and monitoring of the nuclear material flow and inventory; (1) Direct measurement of the inventory cannot be done, (2) Solution rework and reagent adjustment operation in actual plant will make miss-interpretation on the monitoring evaluation. The purpose of ASMS development is to establish quantitative plutonium mass measurement technique directly by NDA of high concentrated pure plutonium nitrate solution and monitoring capability for solution transfers in a process. The merits of ASMS are considered below; (1) Provide direct Pu measurement and continuous monitoring capability, (2) Eliminate sampling and analysis at IIV, (3) Reduce unmeasured inventory. The target of the measurement uncertainty of ASMS is set less than 6% (1sigma) which is equivalent to meet the detection level of the partial defect at IIV by NDA. Known-alpha coincidence counting technique is applied to the ASMS, which is similar to the NDAs for MOX powder as a principle measurement technique. Especially, three following points are key techniques to establish ASMS. (1) Pre-determination of plutonium isotopic composition because it impacts alpha and rho-zero values to obtain multiplication

  20. The Value of Continuous ST-Segment Monitoring in the Emergency Department.

    Science.gov (United States)

    Bovino, Leonie Rose; Funk, Marjorie; Pelter, Michele M; Desai, Mayur M; Jefferson, Vanessa; Andrews, Laura Kierol; Forte, Kenneth

    2015-01-01

    Practice standards for electrocardiographic monitoring recommend continuous ST-segment monitoring (C-STM) in patients presenting to the emergency department (ED) with signs and/or symptoms of acute coronary syndrome (ACS), but few studies have evaluated its use in the ED. We compared time to diagnosis and 30-day adverse events before and after implementation of C-STM. We also evaluated the diagnostic accuracy of C-STM in detecting ischemia and infarction. We prospectively studied 163 adults (preintervention: n = 78; intervention: n = 85) in a single ED and stratified them into low (n = 51), intermediate (n = 100), or high (n = 12) risk using History, ECG, Age, Risk factors, and Troponin (HEART) scores. The principal investigator monitored participants, activating C-STM on bedside monitors in the intervention phase. We used likelihood ratios (LRs) as the measure of diagnostic accuracy. Overall, 9% of participants were diagnosed with ACS. Median time to diagnosis did not differ before and after implementation of C-STM (5.55 vs. 5.98 hr; p = 0.43). In risk-stratified analyses, no significant pre-/postdifference in time to diagnosis was found in low-, intermediate-, or high-risk participants. There was no difference in the rate of 30-day adverse events before versus after C-STM implementation (11.5% vs. 10.6%; p = 0.85). The +LR and -LR of C-STM for ischemia were 24.0 (95% confidence interval [CI]: 1.4, 412.0) and 0.3 (95% CI: 0.02, 2.9), respectively, and for infarction were 13.7 (95% CI: 1.7, 112.3) and 0.7 (95% CI: 0.3, 1.5), respectively. Use of C-STM did not provide added diagnostic benefit for patients with signs and/or symptoms of myocardial ischemia in the ED.

  1. The Shapley value for a fuzzy poverty measurement

    Directory of Open Access Journals (Sweden)

    Lamia ASNAOUI

    2015-05-01

    Full Text Available This article studies the relationship between poverty, inequality and growth. In classical political economic model, we introduce a residual term to maintain the identity of the model. It does not permit us to find the exact contribution of each factor. To derive the results of the decomposition, the Shapley value augmented by the fuzzy approach is used. In order to take its full advantage, it is of interest to calculate the marginal contribution of each factor in the variation of poverty. An application based on individual wellbeing data from Tunisian households is presented to illustrate use of the proposed concepts.

  2. Measuring and monitoring collective attention during shocking events

    Directory of Open Access Journals (Sweden)

    Xingsheng He

    2017-11-01

    Full Text Available Abstract There has been growing interest in leveraging Web-based social and communication technologies for better crisis response. How might the Web platforms be used as an observatory to systematically understand the dynamics of the public’s attention during disaster events? And how could we monitor such attention in a cost-effective way? In this work, we propose an ‘attention shift network’ framework to systematically observe, measure, and analyze the dynamics of collective attention in response to real-world exogenous shocks such as disasters. Through tracing hashtags that appeared in Twitter users’ complete timeline around several violent terrorist attacks, we study the properties of network structures and reveal the temporal dynamics of the collective attention across multiple disasters. Further, to enable an efficient monitoring of the collective attention dynamics, we propose an effective stochastic sampling approach that accounts for the users’ hashtag adoption frequency, connectedness and diversity, as well as data variability. We conduct extensive experiments to show that the proposed sampling approach significantly outperforms several alternative methods in both retaining the network structures and preserving the information with a small set of sampling targets, suggesting the utility of the proposed method in various realistic settings.

  3. Measuring Virtual Simulations Value in Training Exercises - USMC Use Case

    Science.gov (United States)

    2015-12-04

    performance capability, (2) training realism capability, (3) affective reaction level , and (4) training efficiencies. The first three elements combined...included 18 unclassified events and 11 classified events from air combat element (ACE), ground combat element ( GCE ), and logistics combat element...affective reaction data sheets (measurement for affective reaction level element). Discrepancies in data sheet collection totals resulted from fluid

  4. Survey Guidelines and its Reading Criteria for Monitoring and Transmitting Cultural Heritage Values

    Science.gov (United States)

    De Masi, A.

    2015-08-01

    The paper describes reading criteria for an analysis and interpretation of material systems in relation to a built space, survey guidelines and its reading criteria for Cultural Heritage (CH) values'monitoring and transmission. In addition, integrated systems of digital technologies and 2D/3D digitization of CH are introduced for an effective and accurate reading of Venice and Milan's monuments. Specifically, the guidelines for an architectural survey allow to organize and document historic monuments information, and to identify the significant cultural/physical elements of our past in order for them to be preserved and protected for future generations. In addition, in this paper the studied projects introduce a combination of virtual technologies and historical reality with experimenting innovative solutions for CH. From the methodological point of view, this study has made use of the identification of levels of study (LS) differentiated, each of which is capable of identifying categories.

  5. ICT energy efficiency in higher education. Continuous measurement and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Ter Hofte, H. [Novay, Enschede (Netherlands)

    2011-11-15

    Power consumption of information and communications technology (ICT) is rising rapidly worldwide. Reducing (the growth in) energy demand helps to achieve sustainability goals in the area of energy resource depletion, energy security, economy, and ecology. Various governments and industry consortia have set out policies and agreements to reduce the (growth in) demand for energy. In the MJA3 agreements in the Netherlands, various organizations, including all 14 universities and 39 universities of applied sciences pledged to achieve 30% increase in energy efficiency in 2020 compared to 2005. In this report, we argue that using the number of kilowatt-hours of final electricity used for ICT per enrolled student per day (kWh/st/d), should be used as the primary metric for ICT energy efficiency in higher education. For other uses of electricity than ICT in higher education, we express electricity use in kilowatthours per person per day (kWh/p/d). Applying continuous monitoring and management of ICT energy is one approach one could take to increase ICT energy efficiency in education. In households, providing direct (i.e. real-time) feedback about energy use typically results in 5-15% energy savings, whereas indirect feedback (provided some time after consumption occurs), results in less energy savings, typically 0-10%. Continuous measurement of ICT electricity use can be done in a variety of ways. In this report, we distinguish and describe four major measurement approaches: (1) In-line meters, which require breaking the electrical circuit to install the meter; (2) clamp-on-meters, which can be wrapped around a wire; (3) add-ons to existing energy meters, which use analog or digital ports of existing energy meters; (4) software-only measurement, which uses existing network interfaces, protocols and APIs. A measurement approach can be used at one or more aggregation levels: at building level (to measure all electrical energy used in a building, e.g. a datacenter); at

  6. Prognostic value of monitoring tumour markers CA 15-3 and CEA during fulvestrant treatment

    Directory of Open Access Journals (Sweden)

    Locker Gottfried J

    2006-03-01

    Full Text Available Abstract Background At many centres tumour markers are used to detect disease recurrence and to monitor response to therapy in patients with advanced disease, although the real value of serial observation of marker levels remains disputed. In this study, we evaluated the prognostic value of tumour markers for predicting response (partial response [PR], stable disease [SD] ≥ 6 months, de novo disease progression (PD and secondary PD in patients receiving fulvestrant ('Faslodex' 250 mg/month for the treatment of metastatic breast cancer (MBC. Methods Changes in cancer antigen 15–3 (CA 15-3 and carcinoembryonic antigen (CEA were prospectively monitored (monthly and were also evaluated for the 3 months preceding secondary PD. Data from 67 patients with previously treated MBC participating in a Compassionate Use Programme were analysed. Results In patients with a PR (n = 7 [10.4%], a non-significant increase in CA 15-3 occurred during the first 6 months of treatment; CEA was significantly reduced (P = 0.0165. In patients with SD ≥ 6 months (n = 28 [41.8%], both CA 15-3 (P P = 0.0399 levels increased significantly after 6 months treatment. In those experiencing de novo PD (n = 32 [47.8%], CA 15-3 increased significantly (P P = 0.0002 during the same time period. Both CA 15-3 (P P Conclusion CA 15-3 increases in patients progressing on fulvestrant but may also increase in those experiencing clinical benefit; this should not be taken as a sign of PD without verification. Overall, both CA 15-3 and CEA appear to be poor prognostic markers for determining progression in patients receiving fulvestrant.

  7. Option's value - Greek measures fluctuations and their consequences

    Directory of Open Access Journals (Sweden)

    Izabela Pruchnicka-Grabias

    2004-01-01

    Full Text Available Options are financial instruments that can be applied in many situations. Options buyers sell risk which is bought by their sellers who are obliged to reduce it as much as possible. It can be done by using hedging strategies based on Greek letters and options values analysis. The author proves that Greek letters are not constant during the time of option’s life. The paper shows to what extent they are influenced by such factors as risk free interest rate, volatility, underlying asset price and time to maturity. The conclusion is that options sellers must play an active role, i.e. follow fluctuations of all these parameters and modify their hedging portfolios regularly.

  8. Organohalogen diffuse contamination in Firenze and Prato groundwater bodies. investigative monitoring and definition of background values

    Directory of Open Access Journals (Sweden)

    Stefano Menichetti

    2017-03-01

    Full Text Available The experience of the Environmental Protection Agency of Tuscany in the determination of background values start from 2009 with various substances such as metals, non-metals and inorganic, dioxins and various matrices such as soil, groundwater, inland surface waters and coastal marine sediments. The methodologies supplied in literature have been interpreted and integrated to meet the requirements of current legislation and needs for remediation, diffuse pollution and excavated earth in specific areas. The method for diffuse pollution described here focuses on the use of statistical and geostatistical tools and what we present in this paper are some early results of interest obtained from two case studies in the Florence and in the Prato area. The study has been carried out on concentrations of tetrachlorethylene in the two groundwater bodies by identifying a number of frequency classes in the distribution. Each class has been hypothesized as corresponding to a distinct process. The occurrence both in space and time of the classes has been analysed and discussed critically concluding for a background value that has been found similar between the two zones. The investigation conducted on two monitoring stations representing hot-spots, with values in excess on background value has enabled to map spatial distribution of concentrations and to separate plumes from diffuse pollution area. The two areas show some peculiarities: Florence area shows advanced dehalogenation and a clear spatial continuity, whereas in Prato area it is limited with poor spatial continuity suggesting a spreading with vertical motions from still active primary or secondary sources. Observing how the methodological structure would require, to be fully predictive, a greater number of samples, however, the present work want to constitute a first contribution for management of areas subject to diffuse pollution.

  9. A continuous monitor for the measurement of environmental radon

    International Nuclear Information System (INIS)

    Chittaporn, P.; Eisenbud, M.; Harley, N.H.

    1981-01-01

    Although inhaled short-lived 222 Rn daughters deliver the pertinent α dose for assessing human health effects, radon daughters do not of themselves exist in any atmosphere for more than 2-3 hr. Their long-lived parent (3.82 day) 222 Rn supports the daughter activity and it is the transport of 222 Rn which ultimately determines dose. Without an understanding of the long and short-term temporal patterns of indoor and outdoor 222 Rn it is impossible to understand the factors which are important in establishing any human health hazard from the daughters. This work describes a new continuous environmental radon monitor which measures radon alone without interference from radon daughters. The detector is a cylinder (13 cm diameter x 14 cm high), is lined with alpha scintillation phospor on a Mylar substrate and is portable and easily constructed from inexpensive and commercially available materials. (author)

  10. Measurement of sound velocity profiles in fluids for process monitoring

    International Nuclear Information System (INIS)

    Wolf, M; Kühnicke, E; Lenz, M; Bock, M

    2012-01-01

    In ultrasonic measurements, the time of flight to the object interface is often the only information that is analysed. Conventionally it is only possible to determine distances or sound velocities if the other value is known. The current paper deals with a novel method to measure the sound propagation path length and the sound velocity in media with moving scattering particles simultaneously. Since the focal position also depends on sound velocity, it can be used as a second parameter. Via calibration curves it is possible to determine the focal position and sound velocity from the measured time of flight to the focus, which is correlated to the maximum of averaged echo signal amplitude. To move focal position along the acoustic axis, an annular array is used. This allows measuring sound velocity locally resolved without any previous knowledge of the acoustic media and without a reference reflector. In previous publications the functional efficiency of this method was shown for media with constant velocities. In this work the accuracy of these measurements is improved. Furthermore first measurements and simulations are introduced for non-homogeneous media. Therefore an experimental set-up was created to generate a linear temperature gradient, which also causes a gradient of sound velocity.

  11. Measuring the Value of Earth Observation Information with the Gravity Research and Climate Experiment (GRACE) Satellite

    Science.gov (United States)

    Bernknopf, R.; Kuwayama, Y.; Brookshire, D.; Macauley, M.; Zaitchik, B.; Pesko, S.; Vail, P.

    2014-12-01

    Determining how much to invest in earth observation technology depends in part on the value of information (VOI) that can be derived from the observations. We design a framework and then evaluate the value-in-use of the NASA Gravity Research and Climate Experiment (GRACE) for regional water use and reliability in the presence of drought. As a technology that allows measurement of water storage, the GRACE Data Assimilation System (DAS) provides information that is qualitatively different from that generated by other water data sources. It provides a global, reproducible grid of changes in surface and subsurface water resources on a frequent and regular basis. Major damages from recent events such as the 2012 Midwest drought and the ongoing drought in California motivate the need to understand the VOI from remotely sensed data such as that derived from GRACE DAS. Our conceptual framework models a dynamic risk management problem in agriculture. We base the framework on information from stakeholders and subject experts. The economic case for GRACE DAS involves providing better water availability information. In the model, individuals have a "willingness to pay" (wtp) for GRACE DAS - essentially, wtp is an expression of savings in reduced agricultural input costs and for costs that are influenced by regional policy decisions. Our hypothesis is that improvements in decision making can be achieved with GRACE DAS measurements of water storage relative to data collected from groundwater monitoring wells and soil moisture monitors that would be relied on in the absence of GRACE DAS. The VOI is estimated as a comparison of outcomes. The California wine grape industry has features that allow it to be a good case study and a basis for extrapolation to other economic sectors. We model water use in this sector as a sequential decision highlighting the attributes of GRACE DAS input as information for within-season production decisions as well as for longer-term water reliability.

  12. Monitoring and Assessment of Water Retention Measures in Agricultural Land

    Science.gov (United States)

    Výleta, Roman; Danáčová, Michaela; Škrinár, Andrej; Fencík, Róbert; Hlavčová, Kamila

    2017-12-01

    One of the most interesting events, from the environmental impact point of view, is the huge storm rainfall at which soil degradation processes occur. In Slovakia, agricultural areas with a higher slope have been recently increasingly denudated by water erosion processes. Areas having regular problems with muddy floods and denudation of soil particles have been currently identified. This phenomenon has long-term adverse consequences in the agricultural landscape, especially the decline in soil fertility, the influence on soil type and the reduction of depth of the soil profile. In the case of storm rainfall or long-term precipitation, soil particles are being transported and deposited at the foot of the slope, but in many cases the large amounts of sediment are transported by water in the form of muddy floods, while putting settlements and industrial zones at risk, along with contamination and clogging of watercourses and water reservoirs. These unfavourable phenomena may be prevented by appropriate management and application of technical measures, such as water level ditches, erosion-control weirs, terraces and others. The study deals with determination of the soil loss and denudation of soil particles caused by water erosion, as well as with determination of the volume of the surface runoff created by the regional torrential rains in the area of the village of Sobotište. The research is based on the analysis of flood and erosion-control measures implemented in this area. Monitoring of these level ditches for protection against muddy floods has been carried out since 2015 using UAV technology and terrestrial laser scanning. Monitoring is aimed on determination of the volume of the ditch, changes in its capacity and shape in each year. The study evaluates both the effectiveness of these measures to reduce the surface runoff as well as the amount of eroded soil particles depending on climatological conditions. The results of the research point to the good

  13. Measuring the Value of Mortality Risk Reductions in Turkey

    Science.gov (United States)

    Tekeşin, Cem; Ara, Shihomi

    2014-01-01

    The willingness to pay (WTP) for mortality risk reduction from four causes (lung cancer, other type of cancer, respiratory disease, traffic accident) are estimated using random parameter logit model with data from choice experiment for three regions in Turkey. The value of statistical life (VSL) estimated for Afsin-Elbistan, Kutahya-Tavsanli, Ankara and the pooled case are found as 0.56, 0.35, 0.46 and 0.49 million Purchasing Power Parity (PPP) adjusted 2012 US dollars (USD). Different types of risk cause different VSL estimates and we found the lung cancer premium of 213% against traffic accident. The effects of one-year-delayed provision of risk-reduction service are the reduction of WTP by 482 TL ($318 in PPP adjusted USD) per person on average, and the disutility from status-quo (zero risk reduction) against alternative is found to be 891 TL ($589 in PPP adjusted USD) per person on average. Senior discounts of VSL are partially determined by status-quo preference and the amount of discount decreases once the status-quo bias is removed. The peak VSL is found to be for the age group 30–39 and the average VSL for the age group is 0.8 million PPP adjusted USD). Turkey’s compliance to European Union (EU) air quality standard will cause welfare gains of total 373 million PPP adjusted USD for our study areas in terms of reduced number of premature mortality. PMID:25000150

  14. Measuring the Value of Mortality Risk Reductions in Turkey

    Directory of Open Access Journals (Sweden)

    Cem Tekeşin

    2014-07-01

    Full Text Available The willingness to pay (WTP for mortality risk reduction from four causes (lung cancer, other type of cancer, respiratory disease, traffic accident are estimated using random parameter logit model with data from choice experiment for three regions in Turkey. The value of statistical life (VSL estimated for Afsin-Elbistan, Kutahya-Tavsanli, Ankara and the pooled case are found as 0.56, 0.35, 0.46 and 0.49 million Purchasing Power Parity (PPP adjusted 2012 US dollars (USD. Different types of risk cause different VSL estimates and we found the lung cancer premium of 213% against traffic accident. The effects of one-year-delayed provision of risk-reduction service are the reduction of WTP by 482 TL ($318 in PPP adjusted USD per person on average, and the disutility from status-quo (zero risk reduction against alternative is found to be 891 TL ($589 in PPP adjusted USD per person on average. Senior discounts of VSL are partially determined by status-quo preference and the amount of discount decreases once the status-quo bias is removed. The peak VSL is found to be for the age group 30–39 and the average VSL for the age group is 0.8 million PPP adjusted USD. Turkey’s compliance to European Union (EU air quality standard will cause welfare gains of total 373 million PPP adjusted USD for our study areas in terms of reduced number of premature mortality.

  15. Mean values and measures in quantum mechanics and classical mechanics

    International Nuclear Information System (INIS)

    Bass, J.

    1980-01-01

    In quantum mechanics, for a system at a fixed time, the theory of operators associates to every physical quantity X a probability law. But it is not possible to associate a probability law to a pair (X, Y) of operators, when they do not commute. Therefore it is not possible to represent the physical quantities by the usual methods of probability theory. The aim of this paper is to show that, if X, Y are represented by non random functions which are oscillating in such a way that they generate temporal averages their exist pairs of functions X, Y which have properties similar to pairs of operators. To X and to Y it is possible to associate two measures analogous to probability measures, but that is not possible for the pair (X, Y). The functions satisfying to such conditions are the pseudo-random function, a class of stationary functions which is complementary of the class of almost-periodic functions. The construction of these functions makes use of uniformly distributed sequences of real numbers, which constitute a simulation of random variables uniformly distributed over [0, 1]. Their properties are consequences of the ergodic theorems of H. Weyl (1916) and are related to the properties of irrational numbers [fr

  16. Measurement of use value and non-use value of environmental quality consistent with general equilibrium approach

    OpenAIRE

    Naoki Sakamoto; Kazunori Nakajima

    2014-01-01

    This paper proposes the consistent method with general equilibrium models to measure use value and non-use value of large-scale change in environmental quality. First, we develop a general equilibrium model that parameters of the utility function with environmental quality as a dependent variable can be estimated on the basis of the travel cost method and the contingent variation method. Second, we examine to identify the general equilibrium impact of environmental quality by a comparative st...

  17. Short-term biological variation of clinical chemical values in dumeril's monitors (Varanus dumerili)

    DEFF Research Database (Denmark)

    Bertelsen, Mads Frost; Kjelgaard-Hansen, Mads Jens; Howell, Jennifer R.

    2007-01-01

    Plasma biochemical values are routinely used in the medical management of ill reptiles, and for monitoring the health of clinically normal animals. Laboratory tests, including clinical biochemical values, are subject to biological and analytical variation, the magnitude of which determines the ut...

  18. Phase Space Dissimilarity Measures for Structural Health Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bubacz, Jacob A [ORNL; Chmielewski, Hana T [ORNL; Pape, Alexander E [ORNL; Depersio, Andrew J [ORNL; Hively, Lee M [ORNL; Abercrombie, Robert K [ORNL; Boone, Shane [ORNL

    2011-11-01

    A novel method for structural health monitoring (SHM), known as the Phase Space Dissimilarity Measures (PSDM) approach, is proposed and developed. The patented PSDM approach has already been developed and demonstrated for a variety of equipment and biomedical applications. Here, we investigate SHM of bridges via analysis of time serial accelerometer measurements. This work has four aspects. The first is algorithm scalability, which was found to scale linearly from one processing core to four cores. Second, the same data are analyzed to determine how the use of the PSDM approach affects sensor placement. We found that a relatively low-density placement sufficiently captures the dynamics of the structure. Third, the same data are analyzed by unique combinations of accelerometer axes (vertical, longitudinal, and lateral with respect to the bridge) to determine how the choice of axes affects the analysis. The vertical axis is found to provide satisfactory SHM data. Fourth, statistical methods were investigated to validate the PSDM approach for this application, yielding statistically significant results.

  19. New approach to radiation monitoring: citizen based radiation measurement

    International Nuclear Information System (INIS)

    Kuca, P.; Helebrant, J.

    2016-01-01

    Both the Fukushima Dai-chi NPP accident in Japan in 2011 and the Chernobyl NPP accident in USSR in 1986 similarly to the first one have shown a necessity to find a way how to improve confidence of the public to official authorities. It is important especially in such a case of severe accidents with significant consequences in large inhabited areas around the damaged NPP. A lack of public confidence to officials was caused mostly by rather poor communication between official authorities and the public, as well by restricted access to the information for the public. It may have extremely negative impacts on the public understanding of actual situation and its possible risks, on public acceptance of necessary protective measures and participation of the public in remediation of the affected areas. One of possible ways to improve the situation can be implementation of citizen radiation monitoring on voluntary basis. Making sure, the official results are compatible with public self-measured ones, the public probably has more confidence in them. In the Czech Republic the implementation of such an approach is tested in the framework of security research founded by the Czech Ministry of the Interior - the research project RAMESIS solved by SURO. (authors)

  20. Diagnostic value of structural and diffusion imaging measures in schizophrenia

    Directory of Open Access Journals (Sweden)

    Jungsun Lee

    Full Text Available Objectives: Many studies have attempted to discriminate patients with schizophrenia from healthy controls by machine learning using structural or functional MRI. We included both structural and diffusion MRI (dMRI and performed random forest (RF and support vector machine (SVM in this study. Methods: We evaluated the performance of classifying schizophrenia using RF method and SVM with 504 features (volume and/or fractional anisotropy and trace from 184 brain regions. We enrolled 47 patients and 23 age- and sex-matched healthy controls and resampled our data into a balanced dataset using a Synthetic Minority Oversampling Technique method. We randomly permuted the classification of all participants as a patient or healthy control 100 times and ran the RF and SVM with leave one out cross validation for each permutation. We then compared the sensitivity and specificity of the original dataset and the permuted dataset. Results: Classification using RF with 504 features showed a significantly higher rate of performance compared to classification by chance: sensitivity (87.6% vs. 47.0% and specificity (95.9 vs. 48.4% performed by RF, sensitivity (89.5% vs. 48.0% and specificity (94.5% vs. 47.1% performed by SVM. Conclusions: Machine learning using RF and SVM with both volume and diffusion measures can discriminate patients with schizophrenia with a high degree of performance. Further replications are required. Keywords: Classification, Diffusion MRI, Random forest, Support vector machine, Schizophrenia

  1. Monitoring of Landslide Areas with the Use of Contemporary Methods of Measuring and Mapping

    Directory of Open Access Journals (Sweden)

    Skrzypczak Izabela

    2017-03-01

    Full Text Available In recent years, there is an increase of landslide risk observed, which is associated with intensive anthropogenic activities and extreme weather conditions. Appropriate monitoring and proper development of measurements resulting as maps of areas at risk of landslides enables us to estimate the risk in the social and economic aspect. Landslide monitoring in the framework of SOPO project is performed by several methods of measurements: monitoring of surface (GNSS measurement and laser scanning, monitoring in-deepth (inclinometer measurements and monitoring of the hydrological changes and precipitation (measuring changes in water-table and rainfall.

  2. Strain measurements using Fiber Bragg Grating sensors in Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Daniela ENCIU

    2017-06-01

    Full Text Available The paper presents some results obtained within a project of the “NUCLEU” Program financed by the Ministry of Research and Innovation-ANCS. The project supposes, among others, the design and the realization of a demonstrator for strain and stress measurements made with Fiber Bragg Gratings optical sensors. The paper details the construction of the demonstrator. The strain measurements induced in a cantilevered aluminum plate are compared with the analytical values provided by a mathematical model, and with the numerical values obtained by FEM analysis. The consistency of these comparative data indicates the achievement within the project of a level of competence necessary for later use of FBG sensors in the applicative researches involving the aerospace structures monitoring.

  3. Program controlled system for measuring and monitoring the electron coherent radiation spectrum of Yerevan synchrotron

    International Nuclear Information System (INIS)

    Adamyan, F.V.; Vartapetyan, G.A.; Galumyan, P.I.

    1980-01-01

    An automatic system for measurement, processing and control of energy spectrum of polarized photons realized at the Yerevan electron synchrotron is described. For measuring energy spectra of intensive high energy photon beams a pair spectrometer is used which comprises an aluminium target-converter, an analizing magnet and 2 telescopes of scintillation counters for electron-positron pairs registration. the procedure of spectra measurement by the pair spectrometer is reduced to determining the converted e + e - pairs yield at certain values of the H field intensity of the analizing magnet. An algorithm of the data express-processing for operative monitoring of peak energy stability of electron coherent radiation spectrum is given. The spectra measurement results obtained under real experimental conditions are presented

  4. The Impact of Corporate Governance on Financial Performance: (Measured using Accounting and Value-Added based Measures): Evidence from Malaysia

    OpenAIRE

    Abdul Aziz, Khairul Annuar

    2005-01-01

    This paper aims to test empirically which measure, an accounting based financial performance measure such as Return on Equity, Price to Earnings Ratio, Earnings Per Share and Return on Capital Employed; or value-added based financial performance measures such as Economic Value Added and Market Value Added; is more closely related with Corporate Governance Compliance. This paper also aims to study the level of Corporate Governance Compliance of the Smaller Companies listed on the KLSE, the mea...

  5. Measuring Children's Environmental Attitudes and Values in Northwest Mexico: Validating a Modified Version of Measures to Test the Model of Ecological Values (2-MEV)

    Science.gov (United States)

    Schneller, A. J.; Johnson, B.; Bogner, F. X.

    2015-01-01

    This paper describes the validation process of measuring children's attitudes and values toward the environment within a Mexican sample. We applied the Model of Ecological Values (2-MEV), which has been shown to be valid and reliable in 20 countries, including one Spanish speaking culture. Items were initially modified to fit the regional dialect,…

  6. Monitoring of the Syrian rift valley using radon measurement technique in groundwater

    International Nuclear Information System (INIS)

    Jubeli, Y.; Al-Ali, M.A.; Al-Hilall, M.

    1999-07-01

    Radon concentrations in groundwater were measured from six monitoring stations that were distributed along the Syrian rift valley, with time intervals of one month over a span of more than six years from 1992 to 1998. This set of data was integrated and statistically handled in order to be used as a significant base for estimating the range of natural radon background variations in groundwater along the concerned zone. The results reveal that only few anomalous radon values were recorded during the given time-window, which might be caused by tectonic disturbances or otherwise in the study region. (author)

  7. How to measure customer value and its relationship with shareholder value in a business-to-business market

    Directory of Open Access Journals (Sweden)

    Gustavo Bermejo

    2010-10-01

    Full Text Available Intangible assets are difficult to measure, but nowadays the value of the shares of firms in the stock exchange market contains a high percentage of intangible capital and customers are one of the main intangible assets which should be evaluated. This paper presents and discusses some tools to measure the value of customers. But first, it is mandatory to define and clarify the relationships among the concepts of Customer Equity (CE, Life Time Value (LTV and Customer Relationship Management (CRM. LTV is the best financial outcome to measure customer value, so the paper reviews the literature on some mathematical models to calculate LTV. We propose an equation for LTV in order to apply it in a business-to-business market, and an analysis of the influence factors involved in it is made, focusing especially in the link between LTV and shareholder value. Finally, we propose as future lines of research, the relational equity approach as the perfect complement to the customer equity analysis and a way to estimate LTV for actual cases of publicly traded firms using published information.

  8. Vector-valued measure and the necessary conditions for the optimal control problems of linear systems

    International Nuclear Information System (INIS)

    Xunjing, L.

    1981-12-01

    The vector-valued measure defined by the well-posed linear boundary value problems is discussed. The maximum principle of the optimal control problem with non-convex constraint is proved by using the vector-valued measure. Especially, the necessary conditions of the optimal control of elliptic systems is derived without the convexity of the control domain and the cost function. (author)

  9. Examining the Perceived Value of Integration of Earned Value Management with Risk Management-Based Performance Measurement Baseline

    Science.gov (United States)

    Shah, Akhtar H.

    2014-01-01

    Many projects fail despite the use of evidence-based project management practices such as Performance Measurement Baseline (PMB), Earned Value Management (EVM) and Risk Management (RM). Although previous researchers have found that integrated project management techniques could be more valuable than the same techniques used by themselves, these…

  10. Measuring the value of endoscopic retrograde cholangiopancreatography activity: an opportunity to stratify endoscopists on the basis of their value.

    Science.gov (United States)

    Parihar, Vikrant; Moran, Carthage; Maheshwari, Pardeep; Cheriyan, Danny; O'Toole, Aoibhlinn; Murray, Frank; Patchett, Stephen E; Harewood, Gavin C

    2018-07-01

    As finite healthcare resources come under pressure, the value of physician activity is assuming increasing importance. The value in healthcare can be defined as patient health outcomes achieved per monetary unit spent. Even though some attempts have been made to quantify the value of clinician activity, there is little in the medical literature describing the importance of endoscopists' activity. This study aimed to characterize the value of endoscopic retrograde cholangiopancreatography (ERCP) performance of five gastroenterologists. We carried out a retrospective-prospective cohort study using the databases of patients undergoing ERCP between September 2014 and March 2017. We collected data from 1070 patients who underwent ERCP comparing value among the ERCPists at index ERCP. Procedure value was calculated using the formula Q/(T/C), where Q is the quality of procedure, T is the duration of procedure and C is the adjusted for complexity level. Quality and complexity were derived on a 1-4 Likert scale on the basis of American Society for Gastrointestinal Endoscopy criteria; time was recorded (in min) from intubation to extubation. Endoscopist time calculated from procedure time was considered a surrogate marker of cost as individual components of procedure cost were not itemized. In total, 590 procedures were analysed: 465 retrospectively over 24 months and 125 prospectively over 6 months. There was a 32% variation in the value of endoscopist activity in a more substantial retrospective cohort, with an even more considerable 73% variation in a smaller prospective arm. In an analysis of greater than 1000 ERCPs by a small cohort of experienced ERCPists, there was a wide variation in the value of endoscopist activity. Although the precision of estimating procedural costs needs further refinement, these findings show the ability to stratify ERCPists on the basis of the value their activity. As healthcare costs are scrutinized more closely, such value measurements are

  11. Perspectives on the relevance of the circadian time structure to workplace threshold limit values and employee biological monitoring.

    Science.gov (United States)

    Smolensky, Michael H; Reinberg, Alain E; Sackett-Lundeen, Linda

    2017-01-01

    The circadian time structure (CTS) and its disruption by rotating and nightshift schedules relative to work performance, accident risk, and health/wellbeing have long been areas of occupational medicine research. Yet, there has been little exploration of the relevance of the CTS to setting short-term, time-weighted, and ceiling threshold limit values (TLVs); conducting employee biological monitoring (BM); and establishing normative reference biological exposure indices (BEIs). Numerous publications during the past six decades document the CTS substantially affects the disposition - absorption, distribution, metabolism, and elimination - and effects of medications. Additionally, laboratory animal and human studies verify the tolerance to chemical, biological (contagious), and physical agents can differ extensively according to the circadian time of exposure. Because of slow and usually incomplete CTS adjustment by rotating and permanent nightshift workers, occupational chemical and other contaminant encounters occur during a different circadian stage than for dayshift workers. Thus, the intended protection of some TLVs when working the nightshift compared to dayshift might be insufficient, especially in high-risk settings. The CTS is germane to employee BM in that large-amplitude predictable-in-time 24h variation can occur in the concentration of urine, blood, and saliva of monitored chemical contaminants and their metabolites plus biomarkers indicative of adverse xenobiotic exposure. The concept of biological time-qualified (for rhythms) reference values, currently of interest to clinical laboratory pathology practice, is seemingly applicable to industrial medicine as circadian time and workshift-specific BEIs to improve surveillance of night workers, in particular. Furthermore, BM as serial assessments performed frequently both during and off work, exemplified by employee self-measurement of lung function using a small portable peak expiratory flow meter, can

  12. Online monitoring of Mezcal fermentation based on redox potential measurements.

    Science.gov (United States)

    Escalante-Minakata, P; Ibarra-Junquera, V; Rosu, H C; De León-Rodríguez, A; González-García, R

    2009-01-01

    We describe an algorithm for the continuous monitoring of the biomass and ethanol concentrations as well as the growth rate in the Mezcal fermentation process. The algorithm performs its task having available only the online measurements of the redox potential. The procedure combines an artificial neural network (ANN) that relates the redox potential to the ethanol and biomass concentrations with a nonlinear observer-based algorithm that uses the ANN biomass estimations to infer the growth rate of this fermentation process. The results show that the redox potential is a valuable indicator of the metabolic activity of the microorganisms during Mezcal fermentation. In addition, the estimated growth rate can be considered as a direct evidence of the presence of mixed culture growth in the process. Usually, mixtures of microorganisms could be intuitively clear in this kind of processes; however, the total biomass data do not provide definite evidence by themselves. In this paper, the detailed design of the software sensor as well as its experimental application is presented at the laboratory level.

  13. Opportunities and Challenges in Enhancing Value of Annual Glacier Mass Balance Monitoring Examples from Western North America

    Science.gov (United States)

    Pelto, M. S.

    2017-12-01

    Alpine glacier mass balance is the most accurate indicator of glacier response to climate and with retreat of alpine glaciers is one of the clearest signals of global climate change. Completion of long term, representative and homogenous mass balance field measurement of mass balance, compiled by WGMS, is a key climate data record. To ensure a monitoring program remains vital and funded local collaboration and connecting the research to local societal impacts is crucial. Working with local partners in collecting and providing the right data is critical whether their interest is in hydropower, irrigation, municipal supply, hazard reduction and/or aquatic ecosystems. The expansion of remote sensing and modeling capability provides both a challenge to continued relevance and an opportunity for field mass balance programs to expand relevance. In modelling studies of both glacier mass balance and glacier runoff transient balance data has equivalent value with annual balance data, for both calibration runs and as an input variable. This increases the utility of mid-season field observations. Remote sensing provides repeat imagery that often identifies the AAR and transient snowline of a glacier. For runoff assessment understanding the specific percent of glacier surface area that is glacier ice, older firn, and retained snowpack from the previous winter at frequent intervals during the melt season is vital since each region has a different melt factor. A denser field observation network combined with this imagery can provide additional point balance values of ablation that complement the mass balance record. Periodic measurement of mass balance at a denser network using GPR, LIDAR, TLS or probing is required to better understand long term point balance locations and is important at end of the melt season not just beginning, and has value mid-season for modelling. Applications of each of utility of field mass balance observations will be illustrated.

  14. Establishment of a reference value for chromium in the blood for biological monitoring among occupational chromium workers.

    Science.gov (United States)

    Li, Ping; Li, Yang; Zhang, Ji; Yu, Shan-Fa; Wang, Zhi-Liang; Jia, Guang

    2016-10-01

    The concentration of chromium in the blood (CrB) has been confirmed as a biomarker for occupational chromium exposure, but its biological exposure indices (BEIs) are still unclear, so we collected data from the years 2006 and 2008 (Shandong Province, China) to analyze the relationship between the concentration of chromium in the air (CrA) of the workplaces and CrB to establish a reference value of CrB for biological monitoring of occupational workers. The levels of the indicators for nasal injury, kidney (β2 microglobulin (β2-MG)), and genetic damages (8-hydroxy-deoxyguanosine (8-OHdG) and micronucleus (MN)) were measured in all subjects of the year 2011 (Henan Province, China) to verify the protective effect in this reference value of CrB. Compared with the control groups, the concentrations of CrA and CrB in chromium exposed groups were significantly higher (P value of CrB was recommended to 20 μg/L. The levels of nasal injury, β2-MG, 8-OhdG, and MN were not significantly different between the low chromium exposed group (CrB ≤ 20 μg/L) and the control group, while the levels of β2-MG, 8-OHdG, and MN were statistically different in the high chromium exposed group than that in the control group. This research proved that only in occupational workers, CrB could be used as a biomarker to show chromium exposure in the environment. The recommended reference value of CrB was 20 μg/L. © The Author(s) 2015.

  15. Measuring Value-at-Risk and Expected Shortfall of crude oil portfolio using extreme value theory and vine copula

    Science.gov (United States)

    Yu, Wenhua; Yang, Kun; Wei, Yu; Lei, Likun

    2018-01-01

    Volatilities of crude oil price have important impacts on the steady and sustainable development of world real economy. Thus it is of great academic and practical significance to model and measure the volatility and risk of crude oil markets accurately. This paper aims to measure the Value-at-Risk (VaR) and Expected Shortfall (ES) of a portfolio consists of four crude oil assets by using GARCH-type models, extreme value theory (EVT) and vine copulas. The backtesting results show that the combination of GARCH-type-EVT models and vine copula methods can produce accurate risk measures of the oil portfolio. Mixed R-vine copula is more flexible and superior to other vine copulas. Different GARCH-type models, which can depict the long-memory and/or leverage effect of oil price volatilities, however offer similar marginal distributions of the oil returns.

  16. Real-time measurement of electron beam weld penetration in uranium by acoustic emission monitoring

    International Nuclear Information System (INIS)

    Whittaker, J.W.; Murphy, J.L.

    1991-07-01

    High quality electron beam (EB) welds are required in uranium test articles. Acoustic emission (AE) techniques are under development with the goal of measuring weld penetration in real-time. One technique, based on Average Signal Level (ASL) measurement was used to record weld AE signatures. Characteristic AE signatures were recorded for bead-on-plate (BOP) and butt joint (BJ) welds made under varied welding conditions. AE waveforms were sampled to determine what microscopic AE behavior led to the observed macroscopic signature features. Deformation twinning and weld expulsion are two of the main sources of emission. AE behavior was correlated with weld penetration as measured by standard metallographic techniques. The ASL value was found to increase approximately linearly with weld penetration in BJ welds. These results form the basis for a real-time monitoring technique for weld penetration. 5 refs

  17. Go green! Reusing brain monitoring data containing missing values: a feasibility study with traumatic brain injury patients.

    Science.gov (United States)

    Feng, Mengling; Loy, Liang Yu; Zhang, Feng; Zhang, Zhuo; Vellaisamy, Kuralmani; Chin, Pei Loon; Guan, Cuntai; Shen, Liang; King, Nicolas K K; Lee, Kah Keow; Ang, Beng Ti

    2012-01-01

    Despite the wealth of information carried, periodic brain monitoring data are often incomplete with a significant amount of missing values. Incomplete monitoring data are usually discarded to ensure purity of data. However, this approach leads to the loss of statistical power, potentially biased study and a great waste of resources. Thus, we propose to reuse incomplete brain monitoring data by imputing the missing values - a green solution! To support our proposal, we have conducted a feasibility study to investigate the reusability of incomplete brain monitoring data based on the estimated imputation error. Seventy-seven patients, who underwent invasive monitoring of ICP, MAP, PbtO (2) and brain temperature (BTemp) for more than 24 consecutive hours and were connected to a bedside computerized system, were selected for the study. In the feasibility study, the imputation error is experimentally assessed with simulated missing values and 17 state-of-the-art predictive methods. A framework is developed for neuroclinicians and neurosurgeons to determine the best re-usage strategy and predictive methods based on our feasibility study. The monitoring data of MAP and BTemp are more reliable for reuse than ICP and PbtO (2); and, for ICP and PbtO (2) data, a more cautious re-usage strategy should be employed. We also observe that, for the scenarios tested, the lazy learning method, K-STAR, and the tree-based method, M5P, are consistently 2 of the best among the 17 predictive methods investigated in this study.

  18. Measuring the risk of an Iranian banking system using Value at Risk (VaR Model

    Directory of Open Access Journals (Sweden)

    Sudabeh Morshedian Rafiee

    2012-10-01

    Full Text Available Measuring risk of financial institutes and banks plays an important role on managing them. Recent financial turmoil in United States banking system has motivated banking industry to monitor risk factors more closely. In this paper, we present an empirical study to measure the risk of some private banks in Iran called Bank Mellat using Value at Risk (VaR method. The proposed study collects the necessary information for the fiscal year of 2010 and analyses them using regression analysis. The study divides the financial data into two groups where the financial data of the first half of year is considered in the first group and the remaining information for the second half of year 2010 is considered in the second group. The implementation of VaR method indicates that financial risks increase during the time horizon. The study also uses linear regression method where independent variable is time, dependent variable is the financial risk, and the results confirm what we have found in the previous part of the survey.

  19. Evaluation of tissue oxygen measurements for flap monitoring in an animal model

    DEFF Research Database (Denmark)

    Bonde, Christian; Elberg, Jens; Holstein-Rathlou, N.-H.

    2008-01-01

    Tissue oxygen tension (p(ti)O(2)) measurements are common in neurosurgery but uncommon in plastic surgery. We examined this technique as a monitoring method with probe placement in the subcutaneous tissue and addressed the importance of probe placement. Myocutaneous flaps were raised in an animal...... model and p(ti)O(2) measurements performed at different levels in the subcutaneous fat. Flap artery and vein were occluded until a 50% p(ti)O(2) reduction had occurred (T(1/2)). We found no significant effect of depth (P>0.10) on the level of p(ti)O(2). T(1/2)(arterial) was 7.2 minutes and T(1/2)(venous......) was 18 minutes. We found no significant relation between initial levels of p(ti)O(2) and T(1/2). Location of the probe and absolute p(ti)O(2) value is of little relevance for flap monitoring. It is the relative change in p(ti)O(2) that is important. The p(ti)O(2) technique is well suited for monitoring...

  20. Fock-state view of weak-value measurements and implementation with photons and atomic ensembles

    International Nuclear Information System (INIS)

    Simon, Christoph; Polzik, Eugene S.

    2011-01-01

    Weak measurements in combination with postselection can give rise to a striking amplification effect (related to a large ''weak value''). We show that this effect can be understood by viewing the initial state of the pointer as the ground state of a fictional harmonic oscillator. This perspective clarifies the relationship between the weak-value regime and other measurement techniques and inspires a proposal to implement fully quantum weak-value measurements combining photons and atomic ensembles.

  1. Consistency between Self-Reported and Recorded Values for Clinical Measures

    OpenAIRE

    III, Joseph Thomas; Paulet, Mindy; Rajpura, Jigar R.

    2016-01-01

    Objectives. This study evaluated consistency between self-reported values for clinical measures and recorded clinical measures. Methods. Self-reported values were collected for the clinical measures: systolic blood pressure, diastolic blood pressure, glucose level, height, weight, and cholesterol from health risk assessments completed by enrollees in a privately insured cohort. Body mass index (BMI) was computed from reported height and weight. Practitioner recorded values for the clinical me...

  2. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  3. The value of serial FDG PET on therapeutic evaluation and relapse monitoring of lung cancer

    International Nuclear Information System (INIS)

    Zhu Zhaohui; Cheng Wuying; Cui Ruixue; Chen Xin; Hao Li; Dang Yonghong; Zhe Fu; Wang Bocheng

    2004-01-01

    Purpose: A retrospective study was designed to investigate the value of serial FDG PET on therapeutic evaluation and relapse monitoring of lung cancer, and the influence factors to the evaluation and follow-up were also analyzed. Methods: Nineteen patients with confirmed lung cancer were included in the study, and they accepted a total of 87 FDG PET scans, with 3 to 12 times for each patient. The follow-up intervals of FDG PET varied from 14 days to 32 months, and 51 of 68 intervals were within 6 months with a mean of 3.3 months. The PET images of serial studies were analyzed with both visual and semi-quantitative Methods, and they were compared with other imaging techniques (CT, MRI and/or bone scan) and clinical follow-ups. Results: By providing metabolic information, FDG PET detected tumors with high contrast to normal tissue, and the serial examinations helped 9 patients in detecting and evaluating lesions in areas with complicated anatomic structures, such as lung hilus, mediastinum, supraclavicular and abdomen. PET also showed more accuracy and sensitivity than bone scan, CT or MRI in evaluation of bone metastases in two cases. Serial FDG PET was also helpful to the cases in complicated conditions with necrosis, fibrosis or changes of anatomic structures after multiple therapies. In two cases, the follow-up studies confirmed the metastases in the incision wound, which had increasing uptake while it decreased in the repairing wound tissue. By analyzing metabolism of the lesions, PET also showed changes in 3 cases, while they were unconcluded by CT and/or MRI. In some circumstances, benign uptake of FDG influenced the evaluation and monitoring. Inflammation after radiotherapy showed high uptake in 7 cases, and influenced the evaluation of therapy in the serial examinations. Recent use of granulocyte clone stimulation factor (G-CSF) caused diffuse high uptake in bone marrow, and it covered the bone metastases in one case. And in other two cases, diffuse high

  4. Complex Fuzzy Set-Valued Complex Fuzzy Measures and Their Properties

    Science.gov (United States)

    Ma, Shengquan; Li, Shenggang

    2014-01-01

    Let F*(K) be the set of all fuzzy complex numbers. In this paper some classical and measure-theoretical notions are extended to the case of complex fuzzy sets. They are fuzzy complex number-valued distance on F*(K), fuzzy complex number-valued measure on F*(K), and some related notions, such as null-additivity, pseudo-null-additivity, null-subtraction, pseudo-null-subtraction, autocontionuous from above, autocontionuous from below, and autocontinuity of the defined fuzzy complex number-valued measures. Properties of fuzzy complex number-valued measures are studied in detail. PMID:25093202

  5. Northern Mariana Islands Marine Monitoring Team Sea Temperature Measurements

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Site specific monitoring of sea temperature is conducted using submersible temperature dataloggers at selected sites and depths around the islands of Saipan and Rota.

  6. Evaluation the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid

    International Nuclear Information System (INIS)

    Gontijo, Rodrigo Modesto Gadelha

    2011-01-01

    In vivo monitoring techniques consist of identification and quantification of radionuclides present in the whole body and specific organs and tissues. In Vivo monitoring requires the use of detedors which are sensitive to the radiation emitted by radionuclides present in the monitored individual. The results obtained in measurements may present small uncertainties which are within pre-set limits in monitoring programs for occupationally exposed individuais. However, any device used to determine physical quantities present uncertainties in the measured values. The total uncertainty of a measurement result is estimated from the propagation of the uncertainties associated to each parameter of the calculation. This study aims to evaluate the sources of uncertainty associated to the measurement results of in vivo monitoring of iodine 131 in the thyroid, in comparison to the suggested in the General Guide for Estimating Effective Doses from Monitoring Data (Project IDEAS/European Community). The reference values used were the ones for high-energy photons (>100 keV). The measurement uncertainties were divided into two categories: type A and type B. The component of type A represents the statistical fluctuation in the counting of the standard source. Regarding type B, the following variations were presented: detector positioning over the phantom; variation of background radiation; thickness of the overlay tissue over the monitored organ, distribution of the activity in the organ. Besides the parameters suggested by the IDEAS Guide, it has also been evaluated the fluctuation of the counting due to the phantom repositioning, which represents the reproducibility of the measurement geometry. Measurements were performed at the Whole Body Counter Unit of IRD using a scintillation detector Nal (Tl) 3 x3 and a neck-thyroid phantom developed at LABMIVIRD. Scattering factors were calculated and compared in different counting geometries. The results of this study show that the

  7. The value of surrogate markers to monitor cholesterol absorption, synthesis and bioconversion to bile acids under lipid lowering therapies.

    Science.gov (United States)

    Stellaard, Frans; von Bergmann, Klaus; Sudhop, Thomas; Lütjohann, Dieter

    2017-05-01

    Regulation of cholesterol (Chol) homeostasis is controlled by three main fluxes, i.e. intestinal absorption, de novo synthesis (ChS) and catabolism, predominantly as bile acid synthesis (BAS). High serum total Chol and LDL-Chol concentrations in particular are considered risk factors and markers for the development of atherosclerosis. Pharmaceutical treatments to lower serum Chol have focused on reducing absorption or ChS and increasing BAS. Monitoring of these three parameters is complex involving isotope techniques, cholesterol balance experiments and advanced mass spectrometry based analysis methods. Surrogate markers were explored that require only one single fasting blood sample collection. These markers were validated in specific, mostly physiological conditions and during statin treatment to inhibit ChS. They were also applied under cholesterol absorption restriction, but were not validated in this condition. We retrospectively evaluated the use of serum campesterol (Camp), sitosterol (Sit) and cholestanol (Cholol) as markers for cholesterol absorption, lathosterol (Lath) as marker for ChS and 7α-hydroxycholesterol (7α-OH-Ch) and 27-hydroxycholesterol (27-OH-Ch) as markers for BAS under conditions of Chol absorption restriction. Additionally, their values were corrected for Chol concentration (R_sterol or oxysterols). Thirty-seven healthy male omnivore subjects were studied under treatments with placebo (PLAC), ezetimibe (EZE) to inhibit cholesterol absorption, simvastatin (SIMVA) to reduce cholesterol synthesis and a combination of both (EZE+SIMVA). Results were compared to those obtained in 18 pure vegetarian subjects (vegans) whose dietary Chol intake is extremely low. Relative or fractional Chol absorption (FrChA) was measured with the continuous feeding stable isotope procedure, ChS and BAS with the cholesterol balance method. The daily Chol intake (DICh) was inventoried and the daily Chol absorption (DACh) calculated. Monitoring cholesterol

  8. Measuring the value of nonwage employee benefits: building a model of the relation between benefit satisfaction and value.

    Science.gov (United States)

    Weathington, Bart L; Jones, Allan P

    2006-11-01

    Researchers have commonly assumed benefits that employees view as more valuable have a greater influence on their attitudes and behaviors. Researchers have used 2 common methods to measure benefit value: attaching a monetary value to benefits and using self-reports of benefit importance. The present authors propose that the 2 approaches are conceptually distinct and have different implications. They use a social exchange perspective to justify this distinction and integrate both approaches and benefit satisfaction into a more comprehensive model of benefit perception. Results suggest that both measures have practical applications depending on the nature of the exchange relationship between the organization and employees. However, this relationship depends on the specific benefit and on employee satisfaction with that benefit. Some benefits lend themselves to a monetary estimate, whereas others lend themselves more to a nonmonetary valuation.

  9. The value of soil respiration measurements for interpreting and modeling terrestrial carbon cycling

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Claire L.; Bond-Lamberty, Ben; Desai, Ankur R.; Lavoie, Martin; Risk, Dave; Tang, Jianwu; Todd-Brown, Katherine; Vargas, Rodrigo

    2016-11-16

    A recent acceleration of model-data synthesis activities has leveraged many terrestrial carbon (C) datasets, but utilization of soil respiration (RS) data has not kept pace with other types such as eddy covariance (EC) fluxes and soil C stocks. Here we argue that RS data, including non-continuous measurements from survey sampling campaigns, have unrealized value and should be utilized more extensively and creatively in data synthesis and modeling activities. We identify three major challenges in interpreting RS data, and discuss opportunities to address them. The first challenge is that when RS is compared to ecosystem respiration (RECO) measured from EC towers, it is not uncommon to find substantial mismatch, indicating one or both flux methodologies are unreliable. We argue the most likely cause of mismatch is unreliable EC data, and there is an unrecognized opportunity to utilize RS for EC quality control. The second challenge is that RS integrates belowground heterotrophic (RH) and autotrophic (RA) activity, whereas modelers generally prefer partitioned fluxes, and few models include an explicit RS output. Opportunities exist to use the total RS flux for data assimilation and model benchmarking methods rather than less-certain partitioned fluxes. Pushing for more experiments that not only partition RS but also monitor the age of RA and RH, as well as for the development of belowground RA components in models, would allow for more direct comparison between measured and modeled values. The third challenge is that soil respiration is generally measured at a very different resolution than that needed for comparison to EC or ecosystem- to global-scale models. Measuring soil fluxes with finer spatial resolution and more extensive coverage, and downscaling EC fluxes to match the scale of RS, will improve chamber and tower comparisons. Opportunities also exist to estimate RH at regional scales by implementing decomposition functional types, akin to plant functional

  10. The measurement of abundance and content of 148Nd monitor for the determination of burnup with mass spectrometry

    International Nuclear Information System (INIS)

    Gao Shuqin; Li Silin

    1992-09-01

    The abundance and content of nuclide 148 Nd, which is used as monitor to determine reactor element burnup, were measured by mass spectrometry, and the burnup can be calculated from measured results. The distribution of 148 Nd abundance and content in the axial direction are consistent with the theoretical calculation. The burnup values agree with the data obtained from heavy isotope ratio and radiochemistry methods within the errors of 4.0% and 2.8% respectively

  11. Diagnostic value of diffusion-weighted MRI for tumor characterization, differentiation and monitoring in pediatric patients with neuroblastic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Henning [Univ. Hospital Ulm (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Hospital Wuerzburg (Germany). Dept. of Diagnostic and Interventional Radiology; Li, Mengxia [Univ. Hospital Wuerzburg (Germany). Dept. of Radiation Oncology; Mueller, Verena Rabea [Univ. Hospital Wuerzburg (Germany). Dept. of Paediatrics; Pabst, Thomas [Univ. Hospital Wuerzburg (Germany). Dept. of Diagnostic and Interventional Radiology; Beer, Meinrad [Univ. Hospital Ulm (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-07-15

    We explored the diagnostic value of diffusion-weighted MRI (DWI) for tumor characterization, differentiation and therapy monitoring in pediatric patients with extracranial neuroblastic tumors. All 29 patients (14 girls, median age: 3 years) with neuroblastoma (NB, n = 19), ganglioneuroblastoma (GNB, n = 4) and ganglioneuroma (GN, n = 6) who had had at least one in-house DWI examination since 2005 were identified and retrospectively analyzed. Two independent blinded readers measured ADC values (unit: 10-3 mm{sup 2}/s) and signal intensity ratios (SIRs) of the primary tumor and, if applicable, of the tumor after chemotherapy, metastases and tumor relapse. The pre-treatment ADC was 0.90 ± 0.23 in NB/GNB and 1.70 ± 0.36 in GN without overlap between the two entities for both readers, 0.67 ± 0.14 in metastases and 0.72 ± 0.18 in tumor relapse. With chemotherapy, mean ADC increased to 1.54 ± 0.33 in NB/GNB and to 1.23 ± 0.27 in metastases (p < 0.05). The median SIRs of various tumor lesions vs. liver, vs. muscle tissue and vs. adjacent tissue were significantly higher on DWI (range: 2.4 -9.9) than on ce-T1w (range: 1.0 - 1.8, all p < 0.05). The coefficient of variation (CV) was ≤ 8.0% for ADC and ≤ 16.4% for signal intensity data. Based on mean ADC, DWI distinguishes between NB/GNB and GN with high certainty and provides plausible quantitative data on tumor response to therapy. Lesion conspicuity, as measured by SIR, is superior on DWI, compared to ce-T1w. DWI as a noninvasive, radiation-free and widely available imaging technique should be an integral part of MR imaging for neuroblastic tumors and should undergo prospective evaluation in multicenter studies.

  12. A New Measure of Traditional Values Across Cultures: China and Russia Compared

    Directory of Open Access Journals (Sweden)

    Robert J. Taormina

    2016-10-01

    Full Text Available A new measure of adherence to traditional values was created with the objective of facilitating research within and across cultures and nations. The measure was tested in China (N = 321 and Russia (N = 314 and factor analysis of the data revealed two subscales named Personal Traditional Values (10 items and Public Traditional Values (6 items. Empirical psychometric testing of the overall 16-item measure and the two subscales strongly supported the validity and reliability of all three measures. Means comparisons conducted to assess how well the measures could be used for cross-cultural comparisons revealed the Russians somewhat more than the Chinese living by traditional values overall, both nations about equal on living according to traditional values in their personal lives, and the Russians significantly more inclined to abide by traditional values in public. Also tested were several social and psychological variables as theoretical predictors of living by traditional values, and Life Satisfaction was tested as a possible correlate of living according to traditional values. Regression analyses on the combined data confirmed that Family Emotional Support, Conscientiousness, Collectivism, and Age were all significant positive predictors of living by traditional values. Additional regressions also found some unique predictors for each nation. These findings and the results of the parametric tests support the use of the new scales for measuring traditional values both within and across cultures.

  13. A step-by-step plan to manage and measure adding value by FM/CREM

    NARCIS (Netherlands)

    van der Voordt, Theo; Jensen, Per Anker; Hoendervanger, Jan Gerard; Bergsma, Feike; Nielsen, Susanne Balslev; Jensen, Per Anker

    Purpose: To present a new Value Adding Management model in order to support decision makers in identifying appropriate interventions to add value to the organisation, to manage its implementation, and to measure the output and outcomes. Theory: The paper builds on value adding management theories

  14. Evaluation of Isotopic Measurements and Burn-up Value of Sample GU3 of ARIANE Project

    Energy Technology Data Exchange (ETDEWEB)

    Tore, C.; Rodriguez Rivada, A.

    2014-07-01

    Estimation of the burn-up value of irradiated fuel and its isotopic composition are important for criticality analysis, spent fuel management and source term estimation. The practical way to estimate the irradiated fuel composition and burn.up value is calculation with validated code and nuclear data. Such validation of the neutronic codes and nuclear data requires the benchmarking with measured values. (Author)

  15. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    Science.gov (United States)

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  16. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    Science.gov (United States)

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; Pblood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  17. Comparing Multi-Informant Assessment Measures of Parental Monitoring and Their Links with Adolescent Delinquent Behavior

    Science.gov (United States)

    Augenstein, Tara M.; Thomas, Sarah A.; Ehrlich, Katherine B.; Daruwala, Samantha; Reyes, Shelby M.; Chrabaszcz, Jeffrey S.; De Los Reyes, Andres

    2016-01-01

    SYNOPSIS Objective Parents’ poor monitoring of adolescents’ whereabouts and activities is commonly linked to adolescents’ increased engagement in delinquent behaviors. Yet, different domains of parental monitoring (parental monitoring behaviors vs. parental knowledge) and reports from multiple informants (parent vs. adolescent) may vary in their links to delinquent behavior. Design Seventy-four parental caregivers and 74 adolescents completed survey measures of parental monitoring and knowledge, and adolescents completed self-report surveys of delinquent behavior. Results We observed low-to-moderate magnitudes of correspondence between parent- and adolescent-reports of parental monitoring behaviors and parental knowledge. Adolescent self-reported delinquent behavior related to parent and adolescent reports of parental monitoring behaviors and parental knowledge, with adolescents who self-reported engagement in delinquent behaviors evidencing lower levels of parental knowledge and higher levels of poor monitoring compared to adolescents who did not self-report engagement in delinquent behaviors. Adolescent self-reported engagement in delinquent behaviors evidenced stronger links to parental monitoring when based on adolescent reports of monitoring (relative to parent reports), whereas stronger links held between adolescent self-reported delinquent behavior and parental knowledge when based on parent reports of knowledge (relative to adolescent reports). Conclusions Links between monitoring and adolescents’ delinquent behavior vary by the kind of monitoring measure completed as well as the informant completing the measure. These findings inform measurement selection in research and clinical assessments of parental monitoring and adolescent delinquent behavior. PMID:27482171

  18. The Impact of Political Context on the Measurement of Postmaterial Values

    Directory of Open Access Journals (Sweden)

    Bruce Tranter

    2015-06-01

    Full Text Available This research highlights the influence of political context upon the measurement of postmaterial value orientations. Drawing upon a variety of international survey data, Inglehart claims that since World War II a shift has occurred in advanced industrialized nations from material toward postmaterial values. However, cross-sectional data from Australian Election Study surveys collected over more than two decades indicate that atypically for an advanced democracy, Australian value orientations tend toward the materialist pole. Australian Election Study values estimates are also at odds with those from other national social surveys that portray Australia as a far more postmaterialist nation. Regression analysis demonstrates that after controlling for election issues, attitudes toward political leaders, political party identification, and social background, predicted values estimates are substantially more postmaterial than the raw estimates. The findings have international implications as they suggest that measuring values during or soon after election campaigns may affect the measurement of postmaterial value orientations.

  19. Beam profile measurement of ES-200 using secondary electron emission monitor

    Directory of Open Access Journals (Sweden)

    E Ebrahimi Basabi

    2015-09-01

    Full Text Available Up to now, different designs have been introduced for measurement beam profile accelerators. Secondary electron emission monitors (SEM are one of these devices which have been used for this purpose. In this work, a SEM has been constructed to measure beam profile of ES-200 accelerator, a proton electrostatic accelerator which is installed at SBU. Profile grid for both planes designed with 16 wires which are insulated relative to each other. The particles with maximum energy of 200 keV and maximum current of 400 μA are stopped in copper wires. Each of the wires has an individual current-to-voltage amplifier. With a multiplexer, the analogue values are transported to an ADC. The ADCs are read out by a microcontroller and finally profile of beam shows by a user interface program

  20. Measurement comparisons of radioactivity among European monitoring laboratories for the environment and food stuff

    International Nuclear Information System (INIS)

    Waetjen, U.; Spasova, Y.; Altzitzoglou, T.

    2008-01-01

    For more than 15 years, European Union (EU) laboratories monitoring environmental radioactivity have been obliged to participate in measurement comparisons organised by the European Commission. After a short review of comparisons conducted during the 1990s, the approach of IRMM organising these comparisons since 2003 is presented. It relies on the provision of comparison samples with reference values traceable to the International Reference System for radionuclides (SIR). The results of the most recent comparison, the determination of 40 K, 90 Sr and 137 Cs in milk powder, are presented. The influence of repetitive participation in measurement comparisons on laboratory performance is studied on the basis of data from more than 20 laboratories having participated in several exercises during the last 15 years

  1. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

    Science.gov (United States)

    van Gastel, Mark; Stuijk, Sander; de Haan, Gerard

    2016-12-07

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.

  2. Can semiquantitative measurements of SUVmax and cut-off values differentiate colorectal malignant from benign lessions?

    DEFF Research Database (Denmark)

    Nguyen, Tram; Hess, Søren; Petersen, Henrik

    2017-01-01

    , which also precludes a clinically significant cut-off value. The same applies to SUVpeak and SUVmean while TLG measures may be more indicative. CONCLUSION: Semi-quantitative measurements of SUVmax and cut-off values proved inadequate for differentiating colorectal malignancies from benign findings...

  3. Changes in the measurement of fair value : implications for accounting earnings.

    OpenAIRE

    Fargher, N.; Zhang, J.

    2014-01-01

    With the FASB's issue of staff position papers in 2009 and the relaxation of how fair value standards are applied, there has been a change in the practice of how fair value is measured. Since the FASB staff position papers in 2009, fair value measurement by financial institutions has increasingly relied on managerial assumptions. This study examines the impact of this change on the quality of earnings. Consistent with attribute substitution theory that emphasises reliability over relevance, w...

  4. Several Similarity Measures of Interval Valued Neutrosophic Soft Sets and Their Application in Pattern Recognition Problems

    Directory of Open Access Journals (Sweden)

    Anjan Mukherjee

    2014-12-01

    Full Text Available Interval valued neutrosophic soft set introduced by Irfan Deli in 2014[8] is a generalization of neutrosophic set introduced by F. Smarandache in 1995[19], which can be used in real scientific and engineering applications. In this paper the Hamming and Euclidean distances between two interval valued neutrosophic soft sets (IVNS sets are defined and similarity measures based on distances between two interval valued neutrosophic soft sets are proposed. Similarity measure based on set theoretic approach is also proposed. Some basic properties of similarity measures between two interval valued neutrosophic soft sets is also studied. A decision making method is established for interval valued neutrosophic soft set setting using similarity measures between IVNS sets. Finally an example is given to demonstrate the possible application of similarity measures in pattern recognition problems.

  5. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    Science.gov (United States)

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Shaw, Geoffrey M; Chase, J Geoffrey

    2014-05-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. © 2014 Diabetes Technology Society.

  6. Fine PM measurements: personal and indoor air monitoring.

    Science.gov (United States)

    Jantunen, M; Hänninen, O; Koistinen, K; Hashim, J H

    2002-12-01

    This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.

  7. A decision tree model to estimate the value of information provided by a groundwater quality monitoring network

    Science.gov (United States)

    Khader, A. I.; Rosenberg, D. E.; McKee, M.

    2013-05-01

    Groundwater contaminated with nitrate poses a serious health risk to infants when this contaminated water is used for culinary purposes. To avoid this health risk, people need to know whether their culinary water is contaminated or not. Therefore, there is a need to design an effective groundwater monitoring network, acquire information on groundwater conditions, and use acquired information to inform management options. These actions require time, money, and effort. This paper presents a method to estimate the value of information (VOI) provided by a groundwater quality monitoring network located in an aquifer whose water poses a spatially heterogeneous and uncertain health risk. A decision tree model describes the structure of the decision alternatives facing the decision-maker and the expected outcomes from these alternatives. The alternatives include (i) ignore the health risk of nitrate-contaminated water, (ii) switch to alternative water sources such as bottled water, or (iii) implement a previously designed groundwater quality monitoring network that takes into account uncertainties in aquifer properties, contaminant transport processes, and climate (Khader, 2012). The VOI is estimated as the difference between the expected costs of implementing the monitoring network and the lowest-cost uninformed alternative. We illustrate the method for the Eocene Aquifer, West Bank, Palestine, where methemoglobinemia (blue baby syndrome) is the main health problem associated with the principal contaminant nitrate. The expected cost of each alternative is estimated as the weighted sum of the costs and probabilities (likelihoods) associated with the uncertain outcomes resulting from the alternative. Uncertain outcomes include actual nitrate concentrations in the aquifer, concentrations reported by the monitoring system, whether people abide by manager recommendations to use/not use aquifer water, and whether people get sick from drinking contaminated water. Outcome costs

  8. Value of Free-Run Electromyographic Monitoring of Extraocular Cranial Nerves during Expanded Endonasal Surgery (EES) of the Skull Base.

    Science.gov (United States)

    Thirumala, Parthasarathy D; Mohanraj, Santhosh Kumar; Habeych, Miguel; Wichman, Kelley; Chang, Yue-Fang; Gardner, Paul; Snyderman, Carl; Crammond, Donald J; Balzer, Jeffrey

    2013-06-01

    Objective To evaluate the value of free-run electromyography (f-EMG) monitoring of extraocular cranial nerves (EOCN) III, IV, and VI during expanded endonasal surgery (EES) of the skull base in reducing iatrogenic cranial nerve (CN) deficits. Design We retrospectively identified 200 patients out of 990 who had at least one EOCN monitored during EES. We further separated patients into groups according to the specific CN monitored. In each CN group, we classified patients who had significant (SG) f-EMG activity as Group I and those who did not as Group II. Results A total of 696 EOCNs were monitored. The number of muscles supplied by EOCNs that had SG f-EMG activity was 88, including CN III = 46, CN IV = 21, and CN VI = 21. There were two deficits involving CN VI in patients who had SG f-EMG activity during surgery. There were 14 deficits observed, including CN III = 3, CN IV = 2, and CN VI = 9 in patients who did not have SG f-EMG activity during surgery. Conclusions f-EMG monitoring of EOCN during EES can be useful in identifying the location of the nerve. It seems to have limited value in predicting postoperative neurological deficits. Future studies to evaluate the EMG of EOCN during EES need to be done with both f-EMG and triggered EMG.

  9. A step-by-step plan to manage and measure adding value by FM/CREM

    DEFF Research Database (Denmark)

    van der Voordt, Theo; Jensen, Per Anker; Hoendervanger, Jan Gerard

    2016-01-01

    Purpose To present a new Value Adding Management model in order to support decision makers in identifying appropriate interventions to add value to the organisation, to manage its implementation, and to measure the output and outcomes. Theory The paper builds on value adding management theories...... different European countries present a state of the art of theory and research on 12 value parameters, how to manage and measure each value, and to discuss the costs and benefits of typical FM and CREM interventions to enhance satisfaction, image, culture, health and safety, productivity, adaptability...... and models including the triplet input-throughput-output, a distinction between output, outcome and added value, the Plan-Do-Act-Check cycle, change management and performance measurement. Design/methodology/approach Literature review and a cross-chapter analysis of a forthcoming book, where authors from...

  10. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    Science.gov (United States)

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  11. Development and Preliminary Validation of a New Measure of Values in Scientific Work.

    Science.gov (United States)

    English, Tammy; Antes, Alison L; Baldwin, Kari A; DuBois, James M

    2018-04-01

    In this paper we describe the development and initial psychometric evaluation of a new measure, the values in scientific work (VSW). This scale assesses the level of importance that investigators attach to different VSW. It taps a broad range of intrinsic, extrinsic, and social values that motivate the work of scientists, including values specific to scientific work (e.g., truth and integrity) and more classic work values (e.g., security and prestige) in the context of science. Notably, the values represented in this scale are relevant to scientists regardless of their career stage and research focus. We administered the VSW and a measure of global values to 203 NIH-funded investigators. Exploratory factor analyses suggest the delineation of eight VSW, including autonomy, research ethics, social impact, income, collaboration, innovation and growth, conserving relationships, and job security. These VSW showed predictable and distinct associations with global values. Implications of these findings for work on research integrity and scientific misconduct are discussed.

  12. CAP vessel monitoring. Programme, measurement and neutron calculation

    International Nuclear Information System (INIS)

    Farrugia, J.M.; Nimal, J.C.; Totth, B.; Lloret, R.; Perdreau, R.

    1982-03-01

    Starting with the design of the CAP (Prototype Advanced NSSS), a programme for pressure vessel monitoring has been prepared, including dosimetry. The dosimetry programme encompasses activation dosimeters (Cu, Nb, Co) and fission dosimeters ( 237 Np, 238 U) installed either inside the pressure vessel with the monitoring test-samples, or in a counting tube outside the pressure vessel. In the first place, a description of the method for neutronic calculation is given; such calculations use the codes ANISN and MERCURE 4 allowing assessment of the neutron spectrum seen by the detectors and the related reaction coefficient. This is followed by a description of the instrumentation. The initial dosimetry results available after the initial operating cycles concur with calculations [fr

  13. Glucose Monitoring System Based on Osmotic Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Alexandra LEAL

    2011-02-01

    Full Text Available This paper presents the design and development of a prototype sensor unit for implementation in a long-term glucose monitoring system suitable for estimating glucose levels in people suffering from diabetes mellitus. The system utilizes osmotic pressure as the sensing mechanism and consists of a sensor prototype that is integrated together with a pre-amplifier and data acquisition unit for both data recording and processing. The sensor prototype is based on an embedded silicon absolute pressure transducer and a semipermeable nanoporous membrane that is enclosed in the sensor housing. The glucose monitoring system facilitates the integration of a low power microcontroller that is combined with a wireless inductive powered communication link. Experimental verification have proven that the system is capable of tracking osmotic pressure changes using albumin as a model compound, and thereby show a proof of concept for novel long term tracking of blood glucose from remote sensor nodes.

  14. Design of automatic control and measurement software for radioactive aerosol continuity monitor

    International Nuclear Information System (INIS)

    Mao Yong; Li Aiwu

    1997-01-01

    The radioactive aerosol continuity measurement is very important for the development of nuclear industry, and it is the major method to measure and find out the leakage of radioactive material. Radioactive aerosol continuity monitor is the advanced method for the radioactive aerosol continuity measurement. With the development of nuclear industry and nuclear power station, it is necessary to design and automatic continuity measurement device. Because of this reason, the authors developed the first unit of radioactive aerosol continuity monitor and adopted the ministry appraisal. The design idea and method of automatic control and measurement for radioactive aerosol continuity monitor are discussed

  15. CT -guided sclerotherapy for simple renal cysts: Value of ethanol concentration monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jin Hong; Du, Yong; Li, Yang; Yang, Han Feng; Xu, Xiao Xue; Zheng, Hou Jun [The Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2014-02-15

    The aim of our study was to evaluate the differences between sclerotherapy with and without ethanol concentration monitoring for the treatment of simple renal cysts. Sixty-seven patients with 70 simple renal cysts were randomly assigned to two groups in a 12-month prospective controlled trial. One group (group A) was treated with computed tomography (CT)-guided sclerotherapy without ethanol concentration monitoring (33 patients with 35 cysts), whereas the other group (group B) had ethanol concentration monitoring (34 patients with 35 cysts) during the procedure. Treatment outcomes between the two groups were compared 12 months later with follow-up ultrasound examination. After the 12-month follow-up period, the overall success rate was 74.3% in group A and 94.3% in group B (p = 0.022). The mean cyst size before and after treatment was 8.6 ± 2.0 cm and 2.3 ± 2.9 cm, respectively, in group A, and 8.4 ± 1.7 cm and 0.8 ± 1.9 cm, respectively, in group B. The final size of the cysts in group B was significantly smaller than that in group A (p = 0.015). The likelihood of treatment with ethanol concentration monitoring being successful was approximately 16 times higher than without ethanol concentration monitoring (p = 0.026; odds ratio = 15.7; 95% confidence interval: 1.38-179.49). There were no major complications in either group. Monitoring of Hounsfield units (HU) of ethanol by CT is an effective method in the treatment of simple renal cysts with ethanol sclerotherapy. The ethanol sclerotherapy procedure can be terminated at the point of clear fluid aspiration because the HU (-190) of CT scan corresponds to it.

  16. Value of PET and PET-CT for monitoring tumor therapy

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2007-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) PET or PET-CT is an accurate test for differentiating residual viable tumor tissue from therapy-induced changes in tumor. Furthermore, quantitative assessment of therapy-induced changes in tumor 18 F-FDG uptake may allow the prediction of tumor response. Treatment may be adjusted according to tumor response. So it is increasingly used to monitor tumor response in patients undergoing chemotherapy and chemoradiotherapy. Here we focused on practical aspects of 18 F-FDG PET or PET-CT for treatment monitoring and on the existing advantages and challenges. (authors)

  17. Transportation performance measures for outcome based system management and monitoring.

    Science.gov (United States)

    2014-09-01

    The Oregon Department of Transportation (ODOT) is mature in its development and use of : performance measures, however there was not a standard approach for selecting measures nor : evaluating if existing ones were used to inform decision-making. Thi...

  18. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  19. Value, Impact, and the Transcendent Library: Progress and Pressures in Performance Measurement and Evaluation

    Science.gov (United States)

    Town, J. Stephen

    2011-01-01

    Libraries are under pressure to prove their worth and may not have achieved this fully successfully. There is a resultant growing requirement for value and impact measurement in academic and research libraries. This essay reviews the natural history of library performance measurement and suggests that proof of worth will be measured by the…

  20. On the interplay between distortion, mean value and Haezendonck-Goovaerts risk measures

    NARCIS (Netherlands)

    Goovaerts, M.J.; Linders, D.; van Weert, K.; Tank, F.

    2012-01-01

    In the actuarial research, distortion, mean value and Haezendonck-Goovaerts risk measures are concepts that are usually treated separately. In this paper we indicate and characterize the relation between these different risk measures, as well as their relation to convex risk measures. While it is

  1. Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods

    Energy Technology Data Exchange (ETDEWEB)

    Keating, Kristina [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Slater, Lee [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Ntarlagiannis, Dimitris [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Williams, Kenneth H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Earth Sciences Division

    2015-02-24

    This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR) and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements

  2. Feasibility of using a biowatch to monitor GSR as a measure of radiologists' stress and fatigue

    Science.gov (United States)

    Krupinski, Elizabeth A.; MacKinnon, Lea; Reiner, Bruce I.

    2015-03-01

    We have been investigating the impact of fatigue on diagnostic performance of radiologists interpreting medical images. In previous studies we found evidence that eye strain could be objectively measured and that it correlates highly with degradations in diagnostic accuracy as radiologists work long hours. Eye strain however can be difficult to measure in a non-invasive and continuous manner over the work day so we have been investigating other ways to measure physiological stress and fatigue. In this study we evaluated the feasibility of using a commercially available biowatch to measure galvanic skin response (GSR), a well known indicator of stress. 10 radiology residents wore the biowatch for about 8 hours during their normal work day and data were automatically collected at 10 Hz. They completed the Swedish Occupational Fatigue Inventory (SOFI) at the start and finish of the day. GSR values (microsiemens) ranged from 0.14 to 38.27 with an average of 0.50 (0.28 median). Overall GSR tended to be fairly constant as the day progressed, but there were definite spikes indicating higher levels of stress. SOFI scores indicated greater levels of fatigue and stress at the end of the work day. Although further work is needed, GSR measurements obtained via an easy to wear watch may provide a means to monitor stress/fatigue and alert radiologists when to take a break from interpreting images to avoid making errors.

  3. Predictive value of early near-infrared spectroscopy monitoring of patients with traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Alina Vilkė

    2014-01-01

    Conclusions: NIRS plays an important role in the clinical care of TBI patients. Regional brain saturation monitoring provides accurate predictive data, which can improve the allocation of scarce medical resources, set the treatment goals and alleviate the early communication with patients’ relatives.

  4. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    Science.gov (United States)

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  5. Drought monitoring with soil moisture active passive (SMAP) measurements

    Science.gov (United States)

    Mishra, Ashok; Vu, Tue; Veettil, Anoop Valiya; Entekhabi, Dara

    2017-09-01

    Recent launch of space-borne systems to estimate surface soil moisture may expand the capability to map soil moisture deficit and drought with global coverage. In this study, we use Soil Moisture Active Passive (SMAP) soil moisture geophysical retrieval products from passive L-band radiometer to evaluate its applicability to forming agricultural drought indices. Agricultural drought is quantified using the Soil Water Deficit Index (SWDI) based on SMAP and soil properties (field capacity and available water content) information. The soil properties are computed using pedo-transfer function with soil characteristics derived from Harmonized World Soil Database. The SMAP soil moisture product needs to be rescaled to be compatible with the soil parameters derived from the in situ stations. In most locations, the rescaled SMAP information captured the dynamics of in situ soil moisture well and shows the expected lag between accumulations of precipitation and delayed increased in surface soil moisture. However, the SMAP soil moisture itself does not reveal the drought information. Therefore, the SMAP based SWDI (SMAP_SWDI) was computed to improve agriculture drought monitoring by using the latest soil moisture retrieval satellite technology. The formulation of SWDI does not depend on longer data and it will overcome the limited (short) length of SMAP data for agricultural drought studies. The SMAP_SWDI is further compared with in situ Atmospheric Water Deficit (AWD) Index. The comparison shows close agreement between SMAP_SWDI and AWD in drought monitoring over Contiguous United States (CONUS), especially in terms of drought characteristics. The SMAP_SWDI was used to construct drought maps for CONUS and compared with well-known drought indices, such as, AWD, Palmer Z-Index, sc-PDSI and SPEI. Overall the SMAP_SWDI is an effective agricultural drought indicator and it provides continuity and introduces new spatial mapping capability for drought monitoring. As an

  6. Review of measurement techniques for stack monitoring of long-lived alpha emitters

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1978-01-01

    As a result of the promulgation of new guidelines by the Environmental Protection Agency (40 CFR 190) for releases of long-lived, alpha-emitting substances, the stack-monitoring requirements for measuring long-lived alpha particles may change in terms of both monitored isotopes and the detection levels. This paper briefly reviews stack-monitoring requirements for long-lived alpha-emitting particles. It also examines the currently deployed alpha-particulate, stack-monitoring systems and discusses prototype systems that may be applicable to stack monitoring

  7. Learning from your mistakes: The functional value of spontaneous error monitoring in aphasia

    Directory of Open Access Journals (Sweden)

    Erica L. Middleton

    2014-04-01

    Ex. 4.\t(T = umbrella “umbelella, umbrella”: Phonological error; DetCorr We used mixed effects logistic regression to assess whether the log odds of changing from error to correct was predicted by monitoring status of the error (DetCorr vs. NoDet; DetNoCorr vs. NoDet; whether the monitoring benefit interacted with direction of change (forward, backward; and whether effects varied by error type. Figure 1 (top shows that the proportion accuracy change was higher for DetCorr, relative to NoDet, consistent with a monitoring benefit. The difference in log odds was significant for semantic errors in both directions (forward: coeff. = -1.73; z= -7.78; p < .001; backward: coeff = -0.92; z= -3.60; p < .001, and for phonological errors in both directions (forward: coeff. = -0.74; z= -2.73; p=.006; backward : coeff. = -.76; z = -2.73; p = .006. The difference between DetNoCorr and NoDet was not significant in any condition. Figure 1 (bottom shows that for Semantic errors, there was a directional asymmetry favoring the Forward condition (interaction: coeff. = .79; z = 2.32; p = .02. Phonological errors, in contrast, produced comparable effects in Forward and Backward direction. The results demonstrated a benefit for errors that were detected and corrected. This monitoring benefit was present in both the forward and backward direction, supporting the Strength hypothesis. Of greatest interest, the monitoring benefit for Semantic errors was greater in the forward than backward direction, indicating a role for learning.

  8. Evaluation of physical dimension changes as nondestructive measurements for monitoring rigor mortis development in broiler muscles.

    Science.gov (United States)

    Cavitt, L C; Sams, A R

    2003-07-01

    Studies were conducted to develop a non-destructive method for monitoring the rate of rigor mortis development in poultry and to evaluate the effectiveness of electrical stimulation (ES). In the first study, 36 male broilers in each of two trials were processed at 7 wk of age. After being bled, half of the birds received electrical stimulation (400 to 450 V, 400 to 450 mA, for seven pulses of 2 s on and 1 s off), and the other half were designated as controls. At 0.25 and 1.5 h postmortem (PM), carcasses were evaluated for the angles of the shoulder, elbow, and wing tip and the distance between the elbows. Breast fillets were harvested at 1.5 h PM (after chilling) from all carcasses. Fillet samples were excised and frozen for later measurement of pH and R-value, and the remainder of each fillet was held on ice until 24 h postmortem. Shear value and pH means were significantly lower, but R-value means were higher (P rigor mortis by ES. The physical dimensions of the shoulder and elbow changed (P rigor mortis development and with ES. These results indicate that physical measurements of the wings maybe useful as a nondestructive indicator of rigor development and for monitoring the effectiveness of ES. In the second study, 60 male broilers in each of two trials were processed at 7 wk of age. At 0.25, 1.5, 3.0, and 6.0 h PM, carcasses were evaluated for the distance between the elbows. At each time point, breast fillets were harvested from each carcass. Fillet samples were excised and frozen for later measurement of pH and sacromere length, whereas the remainder of each fillet was held on ice until 24 h PM. Shear value and pH means (P rigor mortis development. Elbow distance decreased (P rigor development and was correlated (P rigor mortis development in broiler carcasses.

  9. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    Science.gov (United States)

    Petrenko, A. V.; Valishev, A. A.; Lebedev, V. A.

    2011-09-01

    Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  10. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    Directory of Open Access Journals (Sweden)

    A. V. Petrenko

    2011-09-01

    Full Text Available Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  11. Fair Value Measurement under IFRS 13: A Faithful Representation of Real-World Economic Phenomena?

    OpenAIRE

    Palea Vera; Maino Renato

    2012-01-01

    In this paper, we discuss IFRS 13 with regard to private equity valuation We raise issues on the fair value definition as an exit price and question the reliability of valuation techniques which are categorized into Level 2 fair value hierarchy. Our paper questions whether fair value as defined by IFRS 13 is an appropriate measure for private equities and can contribute to enhancing transparency and comparability in financial statements, which is one of the purposes of the IASB and the Europe...

  12. Why do we buy luxury experiences?: Measuring value perceptions of luxury hospitality services

    OpenAIRE

    Mattila, Anna S.; Yang, Wan

    2015-01-01

    Abstract The luxury segment of the hospitality industry has experienced substantial growth in the past decade. Unfortunately, the notion of perceived luxury values has received scant attention, and there is a lack of a valid framework to capture consumers' value perceptions in the context of luxury hospitality services. Using luxury restaurant as an example of luxury hospitality services, this paper aims to establish the structure of luxury hospitality values and their measures and to inve...

  13. Monitoring of radioiodine and methods for rapid measurement, 2

    International Nuclear Information System (INIS)

    Kamada, Hiroshi

    1979-01-01

    Milk is selected as an indicator or critical food in the environmental monitoring samples, and radioactive iodine as a specific critical radionuclide. Rapid determination of Iodine-131 in the milk has been developed as a standard procedure for the network of environmental radioactivity monitoring in a state of emergency. Outline of the procedure is gamma-ray spectrometry using a heavily shielded 3''diameter x 3'' sodium iodide (thallium-activated) crystal as a detector, 2 liter of Marinelli Beaker for a raw milk and a multi channel pulse height analyzer for quantitative analysis of gamma spectra through the utilization of simultaneous equations. The analysis is what we call ''Milk Matrix Method'' introducing calibration data from the standard samples of Iodine-131, Cesium-137 and Potassium-40. They were selected experimentally, and counting data from the sample were taken into the elements of matrix of set up three simultaneous equations. Most recently detected concentration of Iodine-131 in milk was 81 pCi per liter in 20 May 1978, originated from the nuclear explosion test carried out by the People's Republic of China in 15 May 1978. (author)

  14. Predictive value of noninvasive measures of atherosclerosis for incident myocardial infarction - The Rotterdam study

    NARCIS (Netherlands)

    van der Meer, IM; Bots, ML; Hofman, A; del Sol, AI; van der Kuip, DAM; Witteman, JCM

    2004-01-01

    Background - Several noninvasive methods are available to investigate the severity of extracoronary atherosclerotic disease. No population- based study has yet examined whether differences exist between these measures with regard to their predictive value for myocardial infarction (MI) or whether a

  15. Compilations of measured and calculated physicochemical property values for PCBs, PBDEs, PCDDs and PAHs

    Data.gov (United States)

    U.S. Environmental Protection Agency — The dataset consists of compilations of measured and calculated physicochemical property values for PCBs, PBDEs, PCDDs and PAHs. The properties included in this...

  16. Prognostic Value of Serial ST2 Measurements in Patients With Acute Heart Failure

    NARCIS (Netherlands)

    van Vark, Laura C.; Lesman-Leegte, Ivonne; Baart, Sara J.; Postmus, Douwe; Pinto, Yigal M.; Orsel, Joke G.; Westenbrink, B. Daan; Brunner-la Rocca, Hans P.; van Miltenburg, Addy J. M.; Boersma, Eric; Hillege, Hans L.; Akkerhuis, K. Martijn

    2017-01-01

    Several clinical studies have evaluated the association between ST2 and outcome in patients with heart failure (HF). However, little is known about the predictive value of frequently measured ST2 levels in patients with acute HF. This study sought to describe the prognostic value of baseline and

  17. Stability of Teacher Value-Added Rankings across Measurement Model and Scaling Conditions

    Science.gov (United States)

    Hawley, Leslie R.; Bovaird, James A.; Wu, ChaoRong

    2017-01-01

    Value-added assessment methods have been criticized by researchers and policy makers for a number of reasons. One issue includes the sensitivity of model results across different outcome measures. This study examined the utility of incorporating multivariate latent variable approaches within a traditional value-added framework. We evaluated the…

  18. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women

    NARCIS (Netherlands)

    Bruijn, Merel M. C.; Kamphuis, Esme I.; Hoesli, Irene M.; Martinez de Tejada, Begoña; Loccufier, Anne R.; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M.; Oudijk, Martijn A.; Jacquemyn, Yves; Schulzke, Sven M.; Vetter, Grit; Hoste, Griet; Vis, Jolande Y.; Kok, Marjolein; Mol, Ben W. J.; van Baaren, Gert-Jan

    2016-01-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the

  19. Bird biodiversity assessments in temperate forest: the value of point count versus acoustic monitoring protocols

    Directory of Open Access Journals (Sweden)

    Brian T. Klingbeil

    2015-05-01

    Full Text Available Effective monitoring programs for biodiversity are needed to assess trends in biodiversity and evaluate the consequences of management. This is particularly true for birds and faunas that occupy interior forest and other areas of low human population density, as these are frequently under-sampled compared to other habitats. For birds, Autonomous Recording Units (ARUs have been proposed as a supplement or alternative to point counts made by human observers to enhance monitoring efforts. We employed two strategies (i.e., simultaneous-collection and same-season to compare point count and ARU methods for quantifying species richness and composition of birds in temperate interior forests. The simultaneous-collection strategy compares surveys by ARUs and point counts, with methods matched in time, location, and survey duration such that the person and machine simultaneously collect data. The same-season strategy compares surveys from ARUs and point counts conducted at the same locations throughout the breeding season, but methods differ in the number, duration, and frequency of surveys. This second strategy more closely follows the ways in which monitoring programs are likely to be implemented. Site-specific estimates of richness (but not species composition differed between methods; however, the nature of the relationship was dependent on the assessment strategy. Estimates of richness from point counts were greater than estimates from ARUs in the simultaneous-collection strategy. Woodpeckers in particular, were less frequently identified from ARUs than point counts with this strategy. Conversely, estimates of richness were lower from point counts than ARUs in the same-season strategy. Moreover, in the same-season strategy, ARUs detected the occurrence of passerines at a higher frequency than did point counts. Differences between ARU and point count methods were only detected in site-level comparisons. Importantly, both methods provide similar

  20. Productivity in Pediatric Palliative Care: Measuring and Monitoring an Elusive Metric.

    Science.gov (United States)

    Kaye, Erica C; Abramson, Zachary R; Snaman, Jennifer M; Friebert, Sarah E; Baker, Justin N

    2017-05-01

    Workforce productivity is poorly defined in health care. Particularly in the field of pediatric palliative care (PPC), the absence of consensus metrics impedes aggregation and analysis of data to track workforce efficiency and effectiveness. Lack of uniformly measured data also compromises the development of innovative strategies to improve productivity and hinders investigation of the link between productivity and quality of care, which are interrelated but not interchangeable. To review the literature regarding the definition and measurement of productivity in PPC; to identify barriers to productivity within traditional PPC models; and to recommend novel metrics to study productivity as a component of quality care in PPC. PubMed ® and Cochrane Database of Systematic Reviews searches for scholarly literature were performed using key words (pediatric palliative care, palliative care, team, workforce, workflow, productivity, algorithm, quality care, quality improvement, quality metric, inpatient, hospital, consultation, model) for articles published between 2000 and 2016. Organizational searches of Center to Advance Palliative Care, National Hospice and Palliative Care Organization, National Association for Home Care & Hospice, American Academy of Hospice and Palliative Medicine, Hospice and Palliative Nurses Association, National Quality Forum, and National Consensus Project for Quality Palliative Care were also performed. Additional semistructured interviews were conducted with directors from seven prominent PPC programs across the U.S. to review standard operating procedures for PPC team workflow and productivity. Little consensus exists in the PPC field regarding optimal ways to define, measure, and analyze provider and program productivity. Barriers to accurate monitoring of productivity include difficulties with identification, measurement, and interpretation of metrics applicable to an interdisciplinary care paradigm. In the context of inefficiencies

  1. A new inductive method for measuring the RRR-value of niobium

    International Nuclear Information System (INIS)

    Bolore, M.; Bonin, B.; Boudigou, Y.; Heuveline, S.; Jacques, E.; Jaidane, S.; Koechlin, F.; Safa, H.

    1996-01-01

    A new method for measuring the RRR-value of niobium is presented. The principle of the measurement uses low frequency induction in a niobium sheet placed close to a pair of coils. In contrast with the usual resistive method, the present one gives information on the local value of the RRR, with a spatial resolution of the order of 1 cm. In addition, it is non destructive, thus opening the way to mapping RRR measurements on cavities. This tool will permit the measure of RRR inhomogeneities in cavities due to sheet forming or heat treatments, and the systematic check of the quality of weld seams. (author)

  2. Method and apparatus for real-time measurement of fuel gas compositions and heating values

    Science.gov (United States)

    Zelepouga, Serguei; Pratapas, John M.; Saveliev, Alexei V.; Jangale, Vilas V.

    2016-03-22

    An exemplary embodiment can be an apparatus for real-time, in situ measurement of gas compositions and heating values. The apparatus includes a near infrared sensor for measuring concentrations of hydrocarbons and carbon dioxide, a mid infrared sensor for measuring concentrations of carbon monoxide and a semiconductor based sensor for measuring concentrations of hydrogen gas. A data processor having a computer program for reducing the effects of cross-sensitivities of the sensors to components other than target components of the sensors is also included. Also provided are corresponding or associated methods for real-time, in situ determination of a composition and heating value of a fuel gas.

  3. Representativeness of shorter measurement sessions in long-term indoor air monitoring.

    Science.gov (United States)

    Maciejewska, M; Szczurek, A

    2015-02-01

    Indoor air quality (IAQ) considerably influences health, comfort and the overall performance of people who spend most of their lives in confined spaces. For this reason, there is a strong need to develop methods for IAQ assessment. The fundamental issue in the quantitative determination of IAQ is the duration of measurements. Its inadequate choice may result in providing incorrect information and this potentially leads to wrong conclusions. The most complete information may be acquired through long-term monitoring. However it is typically perceived as impractical due to time and cost load. The aim of this study was to determine whether long-term monitoring can be adequately represented by a shorter measurement session. There were considered three measurable quantities: temperature, relative humidity and carbon dioxide concentration. They are commonly recognized as indicatives for IAQ and may be readily monitored. Scaled Kullback-Leibler divergence, also called relative entropy, was applied as a measure of data representativeness. We considered long-term monitoring in a range from 1 to 9 months. Based on our work, the representative data on CO2 concentration may be acquired while performing measurements during 20% of time dedicated to long-term monitoring. In the case of temperature and relative humidity the respective time demand was 50% of long-term monitoring. From our results, in indoor air monitoring strategies, there could be considered shorter measurement sessions, while still collecting data which are representative for long-term monitoring.

  4. Finite element approximation for time-dependent diffusion with measure-valued source

    Czech Academy of Sciences Publication Activity Database

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  5. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  6. PAMTRAK: A system to monitor high value objects and personnel in restricted areas

    International Nuclear Information System (INIS)

    Anspach, D.A.; Walters, B.G.; Anspach, J.P.; Crain, B. Jr.

    1996-01-01

    The US Department of Energy (DOE) uses sensitive or classified parts and material that must be protected and accounted for. The authors believe there is a need for an automated system that can help protect and monitor these parts and material. In response to this need Sandia National Laboratories (SNL) has developed a real-time personnel and material tracking system called PAMTRAK that has been installed at selected DOE facilities. PAMTRAK safeguards sensitive parts and material by tracking tags worn by personnel and by monitoring sensors attached to the parts or material. This paper describes the goals when designing PAMTRAK, the PAMTRAK system components, the current installations, and the benefits a site can expect when using PAMTRAK

  7. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  8. ATP measurements for monitoring microbial drinking water quality

    DEFF Research Database (Denmark)

    Vang, Óluva Karin

    Current standard methods for surveillance of microbial drinking water quality are culture based, which are laborious and time-consuming, where results not are available before one to three days after sampling. This means that the water may have been consumed before results on deteriorated water....... The overall aim of this PhD study was to investigate various methodological features of the ATP assay for a potential implementation on a sensor platform as a real-time parameter for continuous on-line monitoring of microbial drinking water quality. Commercial reagents are commonly used to determine ATP......, microbial quality in distributed water, detection of aftergrowth, biofilm formation etc. This PhD project demonstrated that ATP levels are relatively low and fairly stable in drinking water without chlorine residual despite different sampling locations, different drinking water systems and time of year...

  9. Inspection frequency required to monitor measurement, recording, or surveillance devices

    International Nuclear Information System (INIS)

    Jaech, J.L.

    1980-01-01

    A problem encountered recently is identical from a mathematical viewpoint to certain types of problems encountered in nuclear materials safeguards. The general form of the solution to the problem in question is therefore of interest in safeguards applications. The specific problem which prompted the investigation is stated as follows. An automatic recording instrument is used in atmospheric monitoring. It is subject to randomly occurring breakdown. The question is, what should be the time interval between the routine checks to provide a specified probability that the recording instrument is functioning properly for at least a given percentage of the time over a specified interval of time. The stated problem is solved in general terms. An application is then made to the specific problem that prompted the study. Applications to specific safeguards problems are left to the reader. 4 refs

  10. Incorporation monitoring with triage measurements in Switzerland; Inkorporationsueberwachung mit Triagemessungen in der Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Elmiger, Raphael [Bundesamt fuer Gesundheit BAG, Liebefeld (Switzerland). Abteilung Strahlenschutz

    2017-08-01

    The actual valid concept of incorporation monitoring in Switzerland was implemented in 1999 with the regulation on personal dosimetry based on the recommendations of an expert group for dosimetry of the Helvetian commission for radiation protection (KSR). IN the sense of an uncomplicated and practical solution for the respective companies it is a two-step monitoring using two different measuring methods: a simplified triage measurement performed by the company and the incorporation measurement by an authorized dosimetry station.

  11. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    Science.gov (United States)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  12. Measurement invariance of the Portrait Values Questionnaire across 25 European countries

    DEFF Research Database (Denmark)

    Scholderer, Joachim

    The Portrait Values Questionnaire (PVQ) is tested for cross-cultural validity. Measurement characteristics are compared across representative consumer samples from 25 European countries (total N = 37,592) using multi-group confirmatory factor analysis with structured means. The results suggest....... Hence, most direct comparisons of PVQ raw scores and sample statistics between European countries are valid without correction. Furthermore, it can be concluded that the ten values measured by the PVQ are invariant across European countries in terms of their relative position on the quasi......-circumplex hypothesised by the theory of basic human values....

  13. Linking Quality and Spending to Measure Value for People with Serious Illness

    Science.gov (United States)

    Rodgers, Phillip E.

    2018-01-01

    Abstract Background: Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. Objective: To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. Design: We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Results: Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending—or are likely to within the next few years—the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. Conclusions: We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs. PMID:29091529

  14. Effect of measurement conditions on three-dimensional roughness values, and development of measurement standard

    International Nuclear Information System (INIS)

    Fabre, A; Brenier, B; Raynaud, S

    2011-01-01

    Friction or corrosion behaviour, fatigue lifetime for mechanical components are influenced by their boundary and subsurface properties. The surface integrity is studied on mechanical component in order to improve the service behaviour of them. Roughness is one of the main geometrical properties, which is to be qualified and quantified. Components can be obtained using a complex process: forming, machining and treatment can be combined to realize parts with complex shape. Then, three-dimensional roughness is needed to characterize these parts with complex shape and textured surface. With contact or non-contact measurements (contact stylus, confocal microprobe, interferometer), three-dimensional roughness is quantified using the calculation of pertinent parameters defined by the international standard PR EN ISO 25178-2:2008. An analysis will identify the influence of measurement conditions on three-dimensional parameters. The purpose of this study is to analyse the variation of roughness results using contact stylus or optical apparatus. The second aim of this work is to develop a measurement standard well adapted to qualify the contact and non-contact apparatus.

  15. Hepatic stiffness measurement by using MR elastography: prognostic values after hepatic resection for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jeong Min; Han, Joon Koo [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Hospital, Institute of Radiation Medicine, Seoul (Korea, Republic of); Yi, Nam-Joon; Lee, Kwang-Woong; Suh, Kyung-Suk [Seoul National University Hospital, Department of Surgery, Seoul (Korea, Republic of); Lee, Jeong-Hoon [Seoul National University Hospital, Department of Internal Medicine, Seoul (Korea, Republic of); Lee, Kyung Bun [Seoul National University Hospital, Department of Pathology, Seoul (Korea, Republic of)

    2017-04-15

    To evaluate prognostic value of hepatic stiffness (HS) measurement using MR elastography (MRE) in patients with hepatocellular carcinoma (HCC) treated by hepatic resection (HR). We enrolled 144 patients with Barcelona Clinic Liver Cancer stage A HCCs initially treated by HR who underwent preoperative liver MRE between January 2010 and June 2013. HS values were measured using MRE. Receiver operating characteristics (ROC) and multivariate logistic regression analyses were used to determine significant predictive factors for posthepatecomy liver failure (PHLF). Overall survival (OS) was analyzed by evaluating prognostic factors using the Kaplan-Meier method and Cox proportional hazard regression model. After HR, 43 patients (29.9 %) experienced PHLF. HS values were significant predictive factors for PHLF. In ROC analysis, the area under the curve of HS was 0.740 (P = 0.001) for PHLF. Thirty-one patients had HS values ≥ 4.02 kPa; the estimated 1, 3, 5-year survival were 90.0 %, 74.7 % and 65.4 %, respectively, versus 98.1 %, 96.5 % and 96.5 % in 113 patients with HS values < 4.02 kPa (P = 0.015). An HS value ≥ 4.02 kPa was the only significant affecting factor for OS. HS values measured by MRE could predict PHLF development post-HR. Furthermore, an HS value ≥4.02 kPa was a significant predicting factor for poor OS post-HR. (orig.)

  16. Measuring the Value of New Drugs: Validity and Reliability of 4 Value Assessment Frameworks in the Oncology Setting.

    Science.gov (United States)

    Bentley, Tanya G K; Cohen, Joshua T; Elkin, Elena B; Huynh, Julie; Mukherjea, Arnab; Neville, Thanh H; Mei, Matthew; Copher, Ronda; Knoth, Russell; Popescu, Ioana; Lee, Jackie; Zambrano, Jenelle M; Broder, Michael S

    2017-06-01

    Several organizations have developed frameworks to systematically assess the value of new drugs. To evaluate the convergent validity and interrater reliability of 4 value frameworks to understand the extent to which these tools can facilitate value-based treatment decisions in oncology. Eight panelists used the American Society of Clinical Oncology (ASCO), European Society for Medical Oncology (ESMO), Institute for Clinical and Economic Review (ICER), and National Comprehensive Cancer Network (NCCN) frameworks to conduct value assessments of 15 drugs for advanced lung and breast cancers and castration-refractory prostate cancer. Panelists received instructions and published clinical data required to complete the assessments, assigning each drug a numeric or letter score. Kendall's Coefficient of Concordance for Ranks (Kendall's W) was used to measure convergent validity by cancer type among the 4 frameworks. Intraclass correlation coefficients (ICCs) were used to measure interrater reliability for each framework across cancers. Panelists were surveyed on their experiences. Kendall's W across all 4 frameworks for breast, lung, and prostate cancer drugs was 0.560 (P= 0.010), 0.562 (P = 0.010), and 0.920 (P fair to excellent, increasing with clinical benefit subdomain concordance and simplicity of drug trial data. Interrater reliability, highest for ASCO and ESMO, improved with clarity of instructions and specificity of score definitions. Continued use, analyses, and refinements of these frameworks will bring us closer to the ultimate goal of using value-based treatment decisions to improve patient care and outcomes. This work was funded by Eisai Inc. Copher and Knoth are employees of Eisai Inc. Bentley, Lee, Zambrano, and Broder are employees of Partnership for Health Analytic Research, a health services research company paid by Eisai Inc. to conduct this research. For this study, Cohen, Huynh, and Neville report fees from Partnership for Health Analytic Research

  17. Online Vce measurement method for wear-out monitoring of high power IGBT modules

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Ghimire, Pramod; de Vega, Angel Ruiz

    2013-01-01

    A simple Vce online monitoring circuit is presented in this paper. It allows an accurate wear out prediction of IGBT modules, in high-power applications, during normal converter operation. Bipolar measurement allows monitoring of both IGBT and antiparallel diode. The circuit uses two serial...... offset due to diodes' forward voltage temperature dependency. Using four diodes one can monitor voltages on all power devices in a converter leg....

  18. Using Commercial Activity Monitors to Measure Gait in Patients with Suspected iNPH: Implications for Ambulatory Monitoring.

    Science.gov (United States)

    Gaglani, Shiv; Moore, Jessica; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele

    2015-11-17

    This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested.

  19. Transcutaneous oximetry measurements of the leg: comparing different measuring equipment and establishing values in healthy young adults.

    Science.gov (United States)

    Trinks, Tobias P; Blake, Denise F; Young, Derelle A; Thistlethwaite, Ken; Vangaveti, Venkat N

    2017-06-01

    Transcutaneous oximetry measurement (TCOM) is a non-invasive method of determining oxygen tension at the skin level using heated electrodes. To compare TCOM values generated by different machines and to establish lower limb TCOM values in a cohort of healthy individuals younger than 40 years of age. Sixteen healthy, non-smoking volunteers aged 18 to 39 years were recruited. TCOM was obtained at six locations on the lower leg and foot using three different Radiometer machines. Measurements were taken with subjects lying supine, breathing air. Except for one sensor site, there were no statistical differences in measurements obtained by the different TCOM machines. There was no statistical difference in measurements comparing left and right legs. Room air TCOM values for the different lower leg sites were (mean (SD) in mmHg): lateral leg 61.5 (9.2); lateral ankle 61.1 (9.7); medial ankle 59.1 (10.8); foot, first and second toe 63.4 (10.6); foot, fifth toe 59.9 (13.2) and plantar foot 74.1 (8.8). The overall mean TCOM value for the lower limb was 61 (10.8; 95% confidence intervals 60.05-62.0) mmHg. Lower-leg TCOM measurements using different Radiometer TCOM machines were comparable. Hypoxia has been defined as lower-leg TCOM values of less than 40 mmHg in non-diabetic patients and this is supported by our measurements. The majority (96.9%) of the lower leg TCOM values in healthy young adults are above the hypoxic threshold.

  20. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  1. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  2. Determinants of the use of value-based performance measures for managerial performance evaluation

    NARCIS (Netherlands)

    Dekker, H.C.; Groot, T.L.C.M.; Schoute, M.; Wiersma, E.

    2012-01-01

    As value-based (VB) performance measures include firms' cost of capital, they are considered more congruent than earnings measures. Prior studies, however, find that their use for managerial performance evaluation is less extensive than their presumed benefits would suggest. We examine how the

  3. Measuring the added value of workplace change. Comparison between Theory and Practice

    NARCIS (Netherlands)

    van der Voordt, Theo; Riratanaphong, C.

    2014-01-01

    Purpose: Worldwide organisations have introduced more flexibility in place, time and ways of working. In order to be able to define the added value of workplace change, a clear performance measurement system is needed to measure organisational performance in connection to real estate before and

  4. Real-time long term measurement using integrated framework for ubiquitous smart monitoring

    Science.gov (United States)

    Heo, Gwanghee; Lee, Giu; Lee, Woosang; Jeon, Joonryong; Kim, Pil-Joong

    2007-04-01

    Ubiquitous monitoring combining internet technologies and wireless communication is one of the most promising technologies of infrastructure health monitoring against the natural of man-made hazards. In this paper, an integrated framework of the ubiquitous monitoring is developed for real-time long term measurement in internet environment. This framework develops a wireless sensor system based on Bluetooth technology and sends measured acceleration data to the host computer through TCP/IP protocol. And it is also designed to respond to the request of web user on real time basis. In order to verify this system, real time monitoring tests are carried out on a prototype self-anchored suspension bridge. Also, wireless measurement system is analyzed to estimate its sensing capacity and evaluate its performance for monitoring purpose. Based on the evaluation, this paper proposes the effective strategies for integrated framework in order to detect structural deficiencies and to design an early warning system.

  5. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Braun, J.; Soederlund, B.

    1960-11-01

    An instrument is described which measures α and β contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers α-pulses, the outer chambers deliver β-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available

  6. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J; Soederlund, B

    1960-11-15

    An instrument is described which measures {alpha} and {beta} contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers {alpha}-pulses, the outer chambers deliver {beta}-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available.

  7. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  8. A scheme of quantum state discrimination over specified states via weak-value measurement

    Science.gov (United States)

    Chen, Xi; Dai, Hong-Yi; Liu, Bo-Yang; Zhang, Ming

    2018-04-01

    The commonly adopted projective measurements are invalid in the specified task of quantum state discrimination when the discriminated states are superposition of planar-position basis states whose complex-number probability amplitudes have the same magnitude but different phases. Therefore we propose a corresponding scheme via weak-value measurement and examine the feasibility of this scheme. Furthermore, the role of the weak-value measurement in quantum state discrimination is analyzed and compared with one in quantum state tomography in this Letter.

  9. Applicability of International and DOE Target Values to ALD Destructive Measurement Applications

    International Nuclear Information System (INIS)

    Holland, M.K.

    2002-01-01

    International Target values and target value applicability are a function of the nuclear material processing campaign or application for which the accountability measurement method is being applied. Safeguarding significant quantities of nuclear-grade materials requires that accountability measurements be as accurate, precise, and representative as practically possible. In general, the ITV provides a benchmark for determining generic acceptability of the performance of the various accountability measurement methods, since it represents a performance level that is accepted as highly reliable. There are cases where it is acceptable to select alternative accountability methods not specifically referenced by the ITV, or to use the recognized measurement method, even though the uncertainties are greater than the target values

  10. Value-based performance measures for Hanford Tank Waste Remedition System (TWRS) Program

    International Nuclear Information System (INIS)

    Keeney, R.L.; von Winterfeldt, D.

    1996-01-01

    The Tank Waste Remediation Systems (TWRS) Program is responsible for the safe storage, retrieval, treatment, and preparation for disposal of high-level waste currently stored in underground storage tanks at the Hanford site in Richland. The TWRS program has adopted a logical approach to decision making that is based on systems engineering and decision analysis (Westinghouse Hanford Company, 1995). This approach involves the explicit consideration of stakeholder values and an evaluation of the TWRS alternatives in terms of these values. Such evaluations need to be consistent across decisions. Thus, an effort was undertaken to develop a consistent, quantifiable set of measures that can be used by TVVRS to assess alternatives against the stakeholder values. The measures developed also met two additional requirements: 1) the number of measure should be relatively small; and 2) performance with respect to the measures should be relatively easy to estimate

  11. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  12. The influence of probe fiber distance on laser Doppler perfusion monitoring measurements

    NARCIS (Netherlands)

    Morales, F; Graaff, R; Smit, AJ; Gush, R; Rakhorst, G

    2003-01-01

    Laser Doppler perfusion monitoring (LDPM) is a noninvasive technique for monitoring skin microcirculation. The aim of this article was to investigate the influence of fiber separation on clinical LDPM measurements. A dual-channel LDPM system was used in combination with a probe that consists of two

  13. Investigating General Chemistry Students' Metacognitive Monitoring of Their Exam Performance by Measuring Postdiction Accuracies over Time

    Science.gov (United States)

    Hawker, Morgan J.; Dysleski, Lisa; Rickey, Dawn

    2016-01-01

    Metacognitive monitoring of one's own understanding plays a key role in learning. An aspect of metacognitive monitoring can be measured by comparing a student's prediction or postdiction of performance (a judgment made before or after completing the relevant task) with the student's actual performance. In this study, we investigated students'…

  14. Progress of the COST Action TU1402 on the Quantification of the Value of Structural Health Monitoring

    DEFF Research Database (Denmark)

    Thöns, Sebastian; Limongelli, Maria Pina; Ivankovic, Ana Mandic

    2017-01-01

    This paper summarizes the development of Value of Structural Health Monitoring (SHM) Information analyses and introduces the development, objectives and approaches of the COST Action TU1402 on this topic. SHM research and engineering has been focused on the extraction of loading, degradation...... for its quantification. This challenge can be met with Value of SHM Information analyses facilitating that the SHM contribution to substantial benefits for life safety, economy and beyond can be may be quantified, demonstrated and utilized. However, Value of SHM Information analyses involve complex models...... encompassing the infrastructure and the SHM systems, their functionality and thus require the interaction of several research disciplines. For progressing on these points, a scientific networking and dissemination project namely the COST Action TU1402 has been initiated....

  15. On set-valued functionals: Multivariate risk measures and Aumann integrals

    Science.gov (United States)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In

  16. Extreme Value Theory Approach to Simultaneous Monitoring and Thresholding of Multiple Risk Indicators

    NARCIS (Netherlands)

    Einmahl, J.H.J.; Li, J.; Liu, R.Y.

    2006-01-01

    Risk assessments often encounter extreme settings with very few or no occurrences in reality.Inferences about risk indicators in such settings face the problem of insufficient data.Extreme value theory is particularly well suited for handling this type of problems.This paper uses a multivariate

  17. Value-Personality Link Measured With Novel Instruments Developed With an Emic Perspective

    Directory of Open Access Journals (Sweden)

    Suna Tevrüz

    2017-05-01

    Full Text Available The first aim of this study is to investigate whether instruments developed with an emic approach in Turkey produce the same trait-value links obtained with studies using near universal instruments, and if emic traits and value concepts are composed under agency and communal conceptions. So, the first aim of this study is to inspect the conceptual similarities in the links between traits and values. The second aim is to examine the moderating effect of disposable income on the strength of the trait-value relationship. Undergraduate and graduate students (N = 595 from six universities in Istanbul responded to the Personality Profile Scale (PPS and the Life Goal Values (LGV questionnaire. Second order factor analysis indicated that indigenous value and trait items were representative of communal and agency conceptions. Furthermore, most of the value-trait links revealed with regression analysis, and the sinusoid relationships revealed with Pearson correlation coefficients were consistent with the findings measured with near universal instruments. Additionally found relationships between traits and especially conservation values can be interpreted as the instrumentality of agentic traits for personal as well for social focused values. Disposable income had a moderating effect on five trait-value relationships and three out of five were weaker in the low-income group.

  18. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    International Nuclear Information System (INIS)

    Yang, Han; Wei, Wu; Chun-Wang, Wu; Hong-Yi, Dai; Cheng-Zu, Li

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given

  19. Realization of arbitrary positive-operator-value measurement of single atomic qubit via cavity QED

    International Nuclear Information System (INIS)

    Han Yang; Wu Wei; Wu Chunwang; Dai Hongyi; Li Chengzu

    2008-01-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given. (authors)

  20. Realization of Arbitrary Positive-Operator-Value Measurement of Single Atomic Qubit via Cavity QED

    Science.gov (United States)

    Han, Yang; Wu, Wei; Wu, Chun-Wang; Dai, Hong-Yi; Li, Cheng-Zu

    2008-12-01

    Positive-operator-value measurement (POVM) is the most general class of quantum measurement. We propose a scheme to deterministically implement arbitrary POVMs of single atomic qubit via cavity QED catalysed by only one ancilla atomic qubit. By appropriately entangling two atomic qubits and sequentially measuring the ancilla qubit, any POVM can be implemented step by step. As an application of our scheme, the realization of a specific POVM for optimal unambiguous discrimination (OUD) between two nonorthogonal states is given.

  1. Monitoring groundwater variation by satellite and implications for in-situ gravity measurements

    International Nuclear Information System (INIS)

    Fukuda, Yoichi; Yamamoto, Keiko; Hasegawa, Takashi; Nakaegawa, Toshiyuki; Nishijima, Jun; Taniguchi, Makoto

    2009-01-01

    In order to establish a new technique for monitoring groundwater variations in urban areas, the applicability of precise in-situ gravity measurements and extremely high precision satellite gravity data via GRACE (Gravity Recovery and Climate Experiment) was tested. Using the GRACE data, regional scale water mass variations in four major river basins of the Indochina Peninsula were estimated. The estimated variations were compared with Soil-Vegetation-Atmosphere Transfer Scheme (SVATS) models with a river flow model of 1) globally uniform river velocity, 2) river velocity tuned by each river basin, 3) globally uniform river velocity considering groundwater storage, and 4) river velocity tuned by each river basin considering groundwater storage. Model 3) attained the best fit to the GRACE data, and the model 4) yielded almost the same values. This implies that the groundwater plays an important role in estimating the variation of total terrestrial storage. It also indicates that tuning river velocity, which is based on the in-situ measurements, needs further investigations in combination with the GRACE data. The relationships among GRACE data, SVATS models, and in-situ measurements were also discussed briefly.

  2. Optimal spatio-temporal design of water quality monitoring networks for reservoirs: Application of the concept of value of information

    Science.gov (United States)

    Maymandi, Nahal; Kerachian, Reza; Nikoo, Mohammad Reza

    2018-03-01

    This paper presents a new methodology for optimizing Water Quality Monitoring (WQM) networks of reservoirs and lakes using the concept of the value of information (VOI) and utilizing results of a calibrated numerical water quality simulation model. With reference to the value of information theory, water quality of every checkpoint with a specific prior probability differs in time. After analyzing water quality samples taken from potential monitoring points, the posterior probabilities are updated using the Baye's theorem, and VOI of the samples is calculated. In the next step, the stations with maximum VOI is selected as optimal stations. This process is repeated for each sampling interval to obtain optimal monitoring network locations for each interval. The results of the proposed VOI-based methodology is compared with those obtained using an entropy theoretic approach. As the results of the two methodologies would be partially different, in the next step, the results are combined using a weighting method. Finally, the optimal sampling interval and location of WQM stations are chosen using the Evidential Reasoning (ER) decision making method. The efficiency and applicability of the methodology are evaluated using available water quantity and quality data of the Karkheh Reservoir in the southwestern part of Iran.

  3. Value of free-run electromyographic monitoring of lower cranial nerves in endoscopic endonasal approach to skull base surgeries.

    Science.gov (United States)

    Thirumala, Parthasarathy D; Mohanraj, Santhosh Kumar; Habeych, Miguel; Wichman, Kelley; Chang, Yue-Fang; Gardner, Paul; Snyderman, Carl; Crammond, Donald J; Balzer, Jeffrey

    2012-08-01

    Objective The main objective of this study was to evaluate the value of free-run electromyography (f-EMG) monitoring of cranial nerves (CNs) VII, IX, X, XI, and XII in skull base surgeries performed using endoscopic endonasal approach (EEA) to reduce iatrogenic CN deficits. Design We retrospectively identified 73 patients out of 990 patients who had EEA in our institution who had at least one CN monitored. In each CN group, we classified patients who had significant (SG) f-EMG activity as group I and those who did not as group II. Results We monitored a total of 342 CNs. A total of 62 nerves had SG f-EMG activity including CN VII = 18, CN IX = 16, CN X = 13, CN XI = 5, and CN XII = 10. No nerve deficit was found in the nerves that had significant activity during procedure. A total of five nerve deficits including (CN IX = 1, CN X = 2, CN XII = 2) were observed in the group that did not display SG f-EMG activity during surgery. Conclusions f-EMG seems highly sensitive to surgical manipulations and in locating CNs. It seems to have limited value in predicting postoperative neurological deficits. Future studies to evaluate the EMG of lower CNs during EEA procedures need to be done with both f-EMG and triggered EMG.

  4. The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations of cyclosporine A after renal transplantation

    Directory of Open Access Journals (Sweden)

    Xiao-Hui Luo

    2011-05-01

    Full Text Available The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT monitoring of blood concentrations of cyclosporine A (CsA in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood ‘trough concentrations (C0 of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 12 months, (185.6 ± 28.1ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14. 1%, significantly lower than that of the none-recommended dose group (37.2% (P < 0.05; the transplantation rejection rate was 4.4%, significantly lower than that of the none-recommended dose group (22.5% (P < 0.05. Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect. Keywords: enzyme-multiplied immunoassay technique, renal transplantation, cyclosporin A, blood concentration monitoring

  5. Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density

    International Nuclear Information System (INIS)

    Gotanda, R.; Takeda, Y.; Gotanda, T.; Oishi Hospital, Hiroshima; Tabuchi, A.; Kawasaki Hospital, Okayama; Yamamoto, K.; Osaka Cancer Prevention and Detection Centre, Osaka; Kuwano, T.; Osaka Medical Center for Cancer and Cardovascular Diseases, Osaka; Yatake, H.; Kaizuka City Hospital, Osaka; Katsuda, T.

    2009-01-01

    The effective energy of diagnostic x-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the applicability of GAFCHROMIC XR type R (GAF-R) film for HVL measurement as an alternative to monitoring with an ionization chamber, a single-strip method for measuring the HVL has been evaluated. Calibration curves of absorbed dose versus film density were generated using this single-strip method with GAF-R film, and the coefficient of determination (r2) of the straight-line approximation was evaluated. The HVLs (effective energies) estimated using the GAF-R film and an ionization chamber were compared. The coefficient of determination (r2) of the straight-line approximation obtained with the GAF-R film was more than 0.99. The effective energies (HVLs) evaluated using the GAF-R film and the ionization chamber were 43.25 keV (5.10 m m) and 39.86 keV (4.45 mm), respectively. The difference in the effective energies determined by the two methods was thus 8.5%. These results suggest that GAF-R might be used to evaluate the effective energy from the film-density growth without the need for ionization-chamber measurements.

  6. Survey Guidelines and its Reading Criteria for Monitoring and Transmitting Cultural Heritage Values

    Directory of Open Access Journals (Sweden)

    A. De Masi

    2015-08-01

    Full Text Available The paper describes reading criteria for an analysis and interpretation of material systems in relation to a built space, survey guidelines and its reading criteria for Cultural Heritage (CH values’monitoring and transmission. In addition, integrated systems of digital technologies and 2D/3D digitization of CH are introduced for an effective and accurate reading of Venice and Milan’s monuments. Specifically, the guidelines for an architectural survey allow to organize and document historic monuments information, and to identify the significant cultural/physical elements of our past in order for them to be preserved and protected for future generations. In addition, in this paper the studied projects introduce a combination of virtual technologies and historical reality with experimenting innovative solutions for CH. From the methodological point of view, this study has made use of the identification of levels of study (LS differentiated, each of which is capable of identifying categories.

  7. Value orientations and environmental beliefs in five countries - Validity of an instrument to measure egoistic, altruistic and biospheric value orientations

    NARCIS (Netherlands)

    de Groot, Judith I. M.; Steg, Linda

    Various scholars argue that egoistic, altruistic, and biospheric value orientations are important for understanding environmental beliefs and behavior. However, little empirical evidence has been provided for the distinction between altruistic and biospheric values. This study examines whether this

  8. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... of serum HIV RNA (p normal allele (p

  9. A research on determination of input levels used in fair value measurement hierarchy by firms listed in Borsa Istanbul

    OpenAIRE

    Gokgoz, Ahmet; Senturk, Fatih

    2015-01-01

    With the coming into force of TFRS 13 Fair Value Measurement Standard, the inputs which firms use for determination of fair value measurement are classified into three levels and hierarchy of determination of fair value is constituted. This standard requires increasing level 1 inputs and decreasing level 3 inputs in determination of fair value. With this study fair value measurement levels (hierarchy) which are used in determination of fair value are described within the scope of TFRS 13 Fair...

  10. Air pollution assessment in the Slovak Republic in 2005. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2006-05-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2005' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  11. Air pollution assessment in the Slovak Republic in 2004. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2005-07-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2004' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  12. Measuring Risk-adjusted Customer Lifetime Value and its Impact on Relationship Marketing Strategies and Shareholder Value

    OpenAIRE

    Ryals, Lynette; Knox, Simon

    2005-01-01

    The calculations which underlie efforts to balance marketing spending on customer acquisition and customer retention are usually based on either single- period customer profitability or forecasts of customer lifetime value (CLTV). This paper argues instead for risk-adjusted CLTV, which is termed the economic value (EV) of a customer, as the means for marketing to assess both customer profitability and shareholder value gains.

  13. The value of spirometry and exercise challenge test to diagnose and monitor children with asthma.

    Science.gov (United States)

    van den Wijngaart, Lara S; Roukema, Jolt; Merkus, Peter Jfm

    2015-03-01

    Asthma is defined as a chronic inflammatory disease of the airways with characteristic symptoms including recurrent episodes of wheezing, breathlessness, chest tightness, and coughing. It may result in abnormalities of ventilator function, which can be assessed by different pulmonary function tests. In this case report, we present a 15-year-old boy with asthma and illustrate the value and limitations of spirometry and exercise challenge test in daily practice.

  14. Comparation of Some Values of Measured Parameteres between Old and New X-Ray Machines

    International Nuclear Information System (INIS)

    Kocic, B.; Marinkovic, J.; Praskalo, J.

    2013-01-01

    Checking the change of values of parameters like specific value of kerma, repeatability of expositions, linearity of exposition, stability of high voltage, time of exposition and HVL of X-ray machines that are in use in medical centres of Republic of Serbia give us an idea of comparing those values for two groups of X-ray machines. One is in use since 70's in last century and is still in use, and the other group is quite new, and is controlled for last 5 years. Checking the results of controlled parameters within those two groups of X-ray machines we can compare stability and quality of old and new machines, and the influence of 'aging' of machines to the quality and stability of measured parameters. Some of conclusions are that old machines are showing better stability and repeatability of values of measured parameters during the 'aging' than new machines.(author)

  15. Analysis and monitoring of energy security and prediction of indicator values using conventional non-linear mathematical programming

    Directory of Open Access Journals (Sweden)

    Elena Vital'evna Bykova

    2011-09-01

    Full Text Available This paper describes the concept of energy security and a system of indicators for its monitoring. The indicator system includes more than 40 parameters that reflect the structure and state of fuel and energy complex sectors (fuel, electricity and heat & power, as well as takes into account economic, environmental and social aspects. A brief description of the structure of the computer system to monitor and analyze energy security is given. The complex contains informational, analytical and calculation modules, provides applications for forecasting and modeling energy scenarios, modeling threats and determining levels of energy security. Its application to predict the values of the indicators and methods developed for it are described. This paper presents a method developed by conventional nonlinear mathematical programming needed to address several problems of energy and, in particular, the prediction problem of the security. An example of its use and implementation of this method in the application, "Prognosis", is also given.

  16. How to measure and monitor antimicrobial consumption and resistance.

    Science.gov (United States)

    Grau, Santiago; Bou, Germán; Fondevilla, Esther; Nicolás, Jordi; Rodríguez-Maresca, Manuel; Martínez-Martínez, Luis

    2013-09-01

    Collateral damage caused by antibiotic use includes resistance, which could be reduced if the global inappropriate use of antibiotics, especially in low-income countries, could be prevented. Surveillance of antimicrobial consumption can identify and target practice areas for quality improvement, both in the community and in healthcare institutions. The defined daily dose, the usual adult dose of an antimicrobial for treating one patient for one day, has been considered useful for measuring antimicrobial prescribing trends within a hospital. Various denominators from hospital activity including beds, admissions and discharges have been used to obtain some standard ratios for comparing antibiotic consumption between hospitals and countries. Laboratory information systems in Clinical Microbiology Services are the primary resource for preparing cumulative reports on susceptibility testing results. This information is useful for planning empirical treatment and for adopting infection control measures. Among the supranational initiatives on resistance surveillance, the EARS-Net provides information about trends on antimicrobial resistance in Europe. Resistance is the consequence of the selective pressure of antibiotics, although in some cases these agents also promote resistance by favouring the emergence of mutations that are subsequently selected. Multiple studies have shown a relationship between antimicrobial use and emergence or resistance. While in some cases a decrease in antibiotic use was associated with a reduction in resistance rates, in many other situations this has not been the case, due to co-resistance and/or the low biological cost of the resistance mechanisms involved. New antimicrobial agents are urgently needed, which coupled with infection control measures will help to control the current problem of antimicrobial resistance. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  17. Microwave Radiometry for Oil Pollution Monitoring, Measurements, and Systems

    DEFF Research Database (Denmark)

    Skou, Niels

    1986-01-01

    Work is presently carried out in Europe to change the Status of the microwave radiometer, namely, to develop it from a research instrument to an operational instrument-especially for measuring oil pollution on the sea surface. The Technical University of Denmark (TUD), with its long experience...... in airborne microwave radiometry, is heavily involved in this process. The TUD multichannel imaging radiometer system has been flown in several large-scale oil-pollution experiments, the collected data have been analyzed, and they have revealed that care must be exercised to obtain accurate oil volume...

  18. Monitoring and measurement of oxygen concentrations in liquid sodium

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-01-01

    The measurement of oxygen concentrations in sodium at levels of interest for LMFBR applications is reviewed. Additional data are presented to support the validity of the vanadium-equilibration method as a reference for determination of oxygen concentrations in sodium at levels equal to or less than 15 ppM. Operating experience with electrochemical oxygen meters that have a thoria-yttria electrolyte and a Na--Na 2 O reference electrode is described. Meter lifetimes in excess of one year have generally been achieved for operating temperatures of 352 and 402 0 C, and fairly stable emfs have been observed for periods of several months. 7 fig, 21 references

  19. Measuring Corporate Sustainability and Environmental, Social, and Corporate Governance Value Added

    Directory of Open Access Journals (Sweden)

    Alena Kocmanová

    2016-09-01

    Full Text Available The aim of the paper is to propose a model for measuring sustainable value which would complexly assess environmental, social, and corporate governance contribution to value creation. In the paper the concept of the Sustainable Environmental, Social and Corporate Governance Value Added is presented. The Sustainable Environmental, Social and Corporate Governance Value Added is based on the Sustainable Value Added model and combines weighted environmental, social, and corporate governance indicators with their benchmarks determined by Data Envelopment Analysis. Benchmark values of indicators were set for each company separately and determine the optimal combination of environmental, social, and corporate governance inputs to economic outcomes. The Sustainable Environmental, Social and Corporate Governance Value Added methodology is applied on real-life corporate data and presented through a case study. The value added of most of the selected companies was negative, even though economic indicators of all of them are positive. The Sustainable Environmental, Social and Corporate Governance Value Added is intended to help owners, investors, and other stakeholders in their decision-making and sustainability assessment. The use of environmental, social, and corporate governance factors helps identify the company’s strengths and weaknesses, and provides a more sophisticated insight into it than the one-dimensional methods based on economic performance alone.

  20. Repeatability and Comparison of Keratometry Values Measured with Potec PRK-6000 Autorefractometer, IOLMaster, and Pentacam

    Directory of Open Access Journals (Sweden)

    Adem Türk

    2014-05-01

    Full Text Available Objectives: To research the repeatability and intercompatibility of keratometry values measured with Potec PRK-6000 autorefractometer, IOL Master, and Pentacam. Materials and Methods: In this prospective study, consecutive measurements were performed in two different sessions with the mentioned three devices on 110 eyes of 55 subjects who had no additional ocular pathology except for refraction error. The consistency of flat and steep keratometry, average keratometry, and corneal astigmatism values obtained in both sessions was compared by using intraclass correlation coefficient (ICC. The measurement differences between the devices were statistically compared as well. Results: The mean age of the study subjects was 23.05±3.01 (18-30 years. ICC values of average keratometry measurements obtained in the sessions were 0.996 for Potec PRK-6000 autorefractometer, 0.997 for IOL Master, and 0.999 for Pentacam. There was high compatibility between the three devices in terms of average keratometry values in Bland-Altman analysis. However, there were statistically significant differences between the devices in terms of parameters other than corneal astigmatism. Conclusion: The repeatability of the three devices was found considerably high in keratometry measurements. However, it is not appropriate for these devices to be substituted for each other in keratometry measurements. (Turk J Ophthalmol 2014; 44: 179-83

  1. Comparison of measurement- and proxy-based Vs30 values in California

    Science.gov (United States)

    Yong, Alan K.

    2016-01-01

    This study was prompted by the recent availability of a significant amount of openly accessible measured VS30 values and the desire to investigate the trend of using proxy-based models to predict VS30 in the absence of measurements. Comparisons between measured and model-based values were performed. The measured data included 503 VS30 values collected from various projects for 482 seismographic station sites in California. Six proxy-based models—employing geologic mapping, topographic slope, and terrain classification—were also considered. Included was a new terrain class model based on the Yong et al. (2012) approach but recalibrated with updated measured VS30 values. Using the measured VS30 data as the metric for performance, the predictive capabilities of the six models were determined to be statistically indistinguishable. This study also found three models that tend to underpredict VS30 at lower velocities (NEHRP Site Classes D–E) and overpredict at higher velocities (Site Classes B–C).

  2. Health-Based Cyanotoxin Guideline Values Allow for Cyanotoxin-Based Monitoring and Efficient Public Health Response to Cyanobacterial Blooms

    Science.gov (United States)

    Farrer, David; Counter, Marina; Hillwig, Rebecca; Cude, Curtis

    2015-01-01

    Human health risks from cyanobacterial blooms are primarily related to cyanotoxins that some cyanobacteria produce. Not all species of cyanobacteria can produce toxins. Those that do often do not produce toxins at levels harmful to human health. Monitoring programs that use identification of cyanobacteria genus and species and enumeration of cyanobacterial cells as a surrogate for cyanotoxin presence can overestimate risk and lead to unnecessary health advisories. In the absence of federal criteria for cyanotoxins in recreational water, the Oregon Health Authority (OHA) developed guideline values for the four most common cyanotoxins in Oregon’s fresh waters (anatoxin-a, cylindrospermopsin, microcystins, and saxitoxins). OHA developed three guideline values for each of the cyanotoxins found in Oregon. Each of the guideline values is for a specific use of cyanobacteria-affected water: drinking water, human recreational exposure and dog recreational exposure. Having cyanotoxin guidelines allows OHA to promote toxin-based monitoring (TBM) programs, which reduce the number of health advisories and focus advisories on times and places where actual, rather than potential, risks to health exist. TBM allows OHA to more efficiently protect public health while reducing burdens on local economies that depend on water recreation-related tourism. PMID:25664510

  3. Measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1976-08-01

    The purpose of this work has been an analysis and evaluation of the state-of-the-art of measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities. The occurrence of plutonium and uranium in the nuclear fuel cycle, the corresponding potential for releases, associated radiological protection standards and monitoring objectives are discussed. Techniques for monitoring via decay radiation from plutonium and uranium isotopes are presented in detail, emphasizing air monitoring, but also including soil sampling and survey methods. Additionally, activation and mass measurement techniques are discussed. The availability and prevalence of these various techniques are summarized. Finally, possible improvements in monitoring capabilities due to alterations in instrumentation, data analysis, or programs are presented

  4. Utilizing Non-Contact Stress Measurement System (NSMS) as a Health Monitor

    Science.gov (United States)

    Hayes, Terry; Hayes, Bryan; Bynum, Ken

    2011-01-01

    Continuously monitor all 156 blades throughout the entire operating envelope without adversely affecting tunnel conditions or compromise compressor shell integrity, Calculate dynamic response and identify the frequency/mode to determine individual blade deflection amplitudes, natural frequencies, phase, and damping (Q), Log static deflection to build a database of deflection values at certain compressor conditions to use as basis for real-time online Blade Stack monitor, Monitor for stall, surge, flutter, and blade damage, Operate with limited user input, low maintenance cost, safe illumination of probes, easy probe replacement, and require little or no access to compressor.

  5. Monitoring groundwater storage changes in the highly dynamic Bengal Basin: validation of GRACE measurements

    Science.gov (United States)

    Shamsudduha, M.; Taylor, R. G.; Longuevergne, L.

    2011-12-01

    Monitoring of spatio-temporal changes in terrestrial water storage (ΔTWS) provides valuable information regarding the basin-scale dynamics of hydrological systems. Recent satellite measurements of the ΔTWS under the Gravity Recovery and Climate Experiment (GRACE) enable the derivation of groundwater storage changes (ΔGWS) where in situ data are limited. In the well monitored and highly-dynamic Bengal Basin of Bangladesh, we test the ability of GRACE measurements to trace the seasonality and trend in groundwater storage associated with intensive groundwater abstraction for dry-season irrigation and wet-season (monsoonal) recharge. Two different GRACE products (CSR and GRGS) and data processing methods (gridded and spherical harmonics) are also compared. Results show that GRACE derived estimates of recent (2003 to 2007) ΔGWS correlate well (r=0.77 to 0.93, p-value CSR for these estimates. ΔGWS accounts for 44% of the total variation in ΔTWS in the Bengal Basin. Changes in surface water storage (ΔSWS) estimated from a network of 298 river gauging stations and soil moisture storage (ΔSMS) derived from Land Surface Models explain 22% and 33% of ΔTWS respectively. Groundwater depletion estimated from borehole hydrographs (-0.52±0.30 km3/yr) is within the range of satellite-derived estimates (-0.44 to -2.04 km3/yr) that result from uncertainty associated with ΔSMS (CLM, NOAH, VIC) and GRACE data processing techniques. Recent (2003 to 2007) estimates of groundwater depletion are substantially greater than the long-term (1985 to 2007) mean (-0.21±0.03 km3/yr) and are explained primarily by substantial increases in groundwater abstraction for the dry-season irrigation and drinking water supplies over the last two decades.

  6. Measurement and monitoring of safety: impact and challenges of putting a conceptual framework into practice.

    Science.gov (United States)

    Chatburn, Eleanor; Macrae, Carl; Carthey, Jane; Vincent, Charles

    2018-03-06

    The Measurement and Monitoring of Safety Framework provides a conceptual model to guide organisations in assessing safety. The Health Foundation funded a large-scale programme to assess the value and impact of applying the Framework in regional and frontline care settings. We explored the experiences and reflections of key participants in the programme. The study was conducted in the nine healthcare organisations in England and Scotland testing the Framework (three regional improvement bodies, six frontline settings). Post hoc interviews with clinical and managerial staff were analysed using template analysis. Participants reported that the Framework promoted a substantial shift in their thinking about how safety is actively managed in their environment. It provided a common language, facilitated a more inquisitive approach and encouraged a more holistic view of the components of safety. These changes in conceptual understanding, however, did not always translate into broader changes in practice, with many sites only addressing some aspects of the Framework. One of the three regions did embrace the Framework in its entirety and achieved wider impact with a range of interventions. This region had committed leaders who took time to fully understand the concepts, who maintained a flexible approach to exploring the utility of the Framework and who worked with frontline staff to translate the concepts for local settings. The Measuring and Monitoring of Safety Framework has the potential to support a broader and richer approach to organisational safety. Such a conceptually based initiative requires both committed leaders who themselves understand the concepts and more time to establish understanding and aims than might be needed in a standard improvement programme. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

    Science.gov (United States)

    Pestel, G; Fukui, K; Higashi, M; Schmidtmann, I; Werner, C

    2018-06-01

    An ideal non-invasive monitoring system should provide accurate and reproducible measurements of clinically relevant variables that enables clinicians to guide therapy accordingly. The monitor should be rapid, easy to use, readily available at the bedside, operator-independent, cost-effective and should have a minimal risk and side effect profile for patients. An example is the introduction of pulse oximetry, which has become established for non-invasive monitoring of oxygenation worldwide. A corresponding non-invasive monitoring of hemodynamics and perfusion could optimize the anesthesiological treatment to the needs in individual cases. In recent years several non-invasive technologies to monitor hemodynamics in the perioperative setting have been introduced: suprasternal Doppler ultrasound, modified windkessel function, pulse wave transit time, radial artery tonometry, thoracic bioimpedance, endotracheal bioimpedance, bioreactance, and partial CO 2 rebreathing have been tested for monitoring cardiac output or stroke volume. The photoelectric finger blood volume clamp technique and respiratory variation of the plethysmography curve have been assessed for monitoring fluid responsiveness. In this manuscript meta-analyses of non-invasive monitoring technologies were performed when non-invasive monitoring technology and reference technology were comparable. The primary evaluation criterion for all studies screened was a Bland-Altman analysis. Experimental and pediatric studies were excluded, as were all studies without a non-invasive monitoring technique or studies without evaluation of cardiac output/stroke volume or fluid responsiveness. Most studies found an acceptable bias with wide limits of agreement. Thus, most non-invasive hemodynamic monitoring technologies cannot be considered to be equivalent to the respective reference method. Studies testing the impact of non-invasive hemodynamic monitoring technologies as a trend evaluation on outcome, as well as

  8. Dollar$ & $en$e. Part IV: Measuring the value of people, structural, and customer capital.

    Science.gov (United States)

    Wilkinson, I

    2001-01-01

    In Part I of this series, I introduced the concept of memes (1). Memes are ideas or concepts, the information world equivalent of genes. The goal of this series of articles is to infect you with my memes, so that you will assimilate, translate, and express them. We discovered that no matter what our area of expertise or "-ology," we all are in the information business. Our goal is to be in the wisdom business. We saw that when we convert raw data into wisdom we are moving along a value chain. Each step in the chain adds a different amount of value to the final product: timely, relevant, accurate, and precise knowledge which can then be applied to create the ultimate product in the value chain: wisdom. In Part II of this series, I infected you with a set of memes for measuring the cost of adding value (2). In Part III of this series, I infected you with a new set of memes for measuring the added value of knowledge, i.e., intellectual capital (3). In Part IV of this series, I will infect you with memes for measuring the value of people, structural, and customer capital.

  9. Measurements and monitoring of phototherapy in newborn jaundice

    International Nuclear Information System (INIS)

    Sisson, T.R.

    1982-01-01

    Hyperbilirubinemia in the newborn (neonatal jaundice) may cause irreversible brain damage if plasma concentrations of bilirubin exceed the number of binding sites on albumin and other blood components. Phototherapy or exchange transfusions to prevent the excessive rise in concentration of the pigment should be instituted in appropriate clinical situations. In phototherapy, the jaundiced infant is exposed to visible light containing the wavelength (about 450 nm) bilirubin will absorb. Because bilirubin is quite photolabile and will readily isomerize in vivo, it is rapidly converted to excretable forms. The effectiveness of this therapy, however, depends upon the maintenance of adequate radiant flux in the required wavelength. Energy output and spectral distributions of phototherapy lamps must be measured. The long-term effects of irradiation of newborn infants over several days are not yet known

  10. Relevance of free cash flow as a measure of generating value for owners

    Directory of Open Access Journals (Sweden)

    Bešlić Ivana

    2014-01-01

    Full Text Available In the new economy or knowledge economy the main goal of any company should be directed towards the achievement of the business in the interest of the owners, or generating the value for owners. In dynamic business environment, an effective performance measurement system is key determinant of successful implementation of corporate strategy, growth and survival of the company. Modern performance measures should provide an accurate assessment of the intrinsic value of the company, as well as the value for the owners (shareholders. The essence is maximizing the immanent or guaranteed value of the company. The immanent value is the value of a company based on internal evaluation (assessment discounted cash flows or expected cash flow in the future by the management team. Corporate managers in Serbia are facing the challenge of increasingly efficient capital markets and the competition in the future, which requires the implementation of a value oriented corporate governance, therefore this paper presents FCF (Free Cash Flow methodology of valuation. Free cash flow (FCF is the amount of cash available for owners of the company after the necessary investments in fixed assets and working capital to maintain the current scope of activities and support to planning.

  11. Measurement of the G-value for 1. 5 keV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, J.P.; Schillaci, M.E.; Raju, M.R. (Los Alamos National Lab., NM (USA))

    1989-12-01

    Using a ferrous sulfate solution modified by the addition of benzoic acid, the authors measured relative G-values for Al{sub k} characteristic X-rays (1.5keV), {sup 238}Pu {alpha}-particles (3.7MeV), {sup 60}Co (1.17 MeV) and {sup 137}Cs (0.66 MeV){gamma}-rays. Relative ferrous-to-ferric conversions as a function of dose were similar for the two {gamma}-ray energies, yielding G-values of 1.62 and 1.59 {mu}mol J{sup -1} for the {sup 60}Co and {sup 137}Cs radiations. The {alpha}-particle G-value was 0.52 {mu}mol J{sup -1}, or 31% of that for {sup 60}Co {gamma}-rays. The Al{sub k} X-rays had a G-value of 0.92 {mu}mol J{sup -1} or 57% of that of the {sup 60}Co radiation. This G-value for 1.5 keV X-rays is within 20% of values predicted by current theories, and theoretical values are within the error range of the authors' measurements. (author).

  12. CORRECTION OF GLOBAL AND REFLEX RADIATION VALUES MEASURED ABOVE THE LAKE BALATON

    Directory of Open Access Journals (Sweden)

    Laszlo Menyhart

    2014-03-01

    Full Text Available Albedo measurements have been carried out since 2007 above the Lake Balaton near Keszthely and Siofok. It turned out that a systematic offset error was superposed to both the global and the reflex radiation. The value of this systematic error was approximately constant per pyranometer within a year but on the other hand it varied from year to year and from pyranometer to pyranometer. In this paper the values of this systematic errors were determined with two different methods. The difference between the values measured at night-time and the intrinsic thermal offset error of pyranometers were examined with both methods. The base of the first method is the empirical observation, that the values measured at night-time by a global radiometer are typically negative whereas by a reflex radiometer are typically positive. The substance of the second method is utilizing the air temperature measured within 1 as well as 5 hours before the radiation measuring to +select the fully overcast nights, when the thermal offset error of the global radiometer is zero. In addition, the cases where the thermal offset error of the reflex radiometer is zero were selected on the basis of the difference between water and air temperature. When the thermal offset error is zero the measured value is equal to the systematic error. Comparing the results of the two methods showed that the systematic error of the global radiometer were determined with uncertainty of 1 Wm–2, whereas that of the reflex radiometer with uncertainty of 2 Wm–2. The calibration constants were recalculated from the values being in the calibration reports taking the systematic errors into account.

  13. An automated A-value measurement tool for accurate cochlear duct length estimation.

    Science.gov (United States)

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit

  14. Peptide self-association in aqueous trifluoroethanol monitored by pulsed field gradient NMR diffusion measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yao Shenggen [Biomolecular Research Institute (Australia); Howlett, Geoffrey J. [University of Melbourne, Department of Biochemistry and Molecular Biology (Australia); Norton, Raymond S. [Biomolecular Research Institute (Australia)

    2000-02-15

    Defining the self-association state of a molecule in solution can be an important step in NMR-based structure determination. This is particularly true of peptides, where there can be a relatively small number of long-range interactions and misinterpretation of an intermolecular NOE as an intramolecular contact can have a dramatic influence on the final calculated structure. In this paper, we have investigated the use of translational self-diffusion coefficient measurements to detect self-association in aqueous trifluoroethanol of three peptides which are analogues of the C-terminal region of human neuropeptide Y. Experimentally measured diffusion coefficients were extrapolated to D{sup 0}, the limiting value as the peptide concentration approaches zero, and then converted to D{sub 20,w}, the diffusion coefficient after correction for temperature and the viscosity of the solvent. A decrease in D{sub 20,w} of about 16% was found for all three peptides in aqueous TFE (30% by volume) compared with water, which is in reasonable agreement with the expected decrease upon dimerisation, the presence of which was indicated by sedimentation equilibrium measurements. Apparent molecular masses of these peptides in both solutions were also calculated from their diffusion coefficients and similar results were obtained. Several potential internal standards, including acetone, acetonitrile, dimethylsulfoxide and dioxane, were assessed as monitors of solution viscosity over a range of trifluoroethanol concentrations. Compared with independent measurements of viscosity, acetonitrile was the most accurate standard among these four. The practical limitations of a quantitative assessment of peptide self-association from translational diffusion coefficients measured by PFGNMR, including the calculation of apparent molecular mass, are also discussed.

  15. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    Directory of Open Access Journals (Sweden)

    F. J. Cullinan

    2015-11-01

    Full Text Available The Compact Linear Collider (CLIC requires beam position monitors (BPMs with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3 at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2/3  ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  16. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    Science.gov (United States)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.; Lefevre, T.; Lunin, A.; Lyapin, A.; Søby, L.; Towler, J.; Wendt, M.

    2015-11-01

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2 /3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  17. Towards better service in restaurants by monitoring trends: Display of nutritional values on the menus

    Directory of Open Access Journals (Sweden)

    Ivkov Milan

    2015-01-01

    Full Text Available Business obligations, the manner and pace of life today, and a large number of options when it comes to eating out, require that at least one meal is consumed outside the residence or using the services of catering and retail facilities. With this in mind, restaurants are forced to fight in the market and to differentiate the specific offer to attract a particular segment of the market. Differentiation is possible through monitoring the trends and timely adjustments to more demanding consumer needs. In this way, restaurateurs also contribute to greater customer satisfaction through quality service, which also has a positive effect on the restaurant and sales performance. Based on the results of the survey of 82 respondents, it was concluded that nutritional information shown within menus is of no importance, and also that such information does not affect the selection of dishes. Although nutritional information can be helpful in selecting more favourable and healthy food, neither men nor women care about it.

  18. Calculating meal glycemic index by using measured and published food values compared with directly measured meal glycemic index.

    Science.gov (United States)

    Dodd, Hayley; Williams, Sheila; Brown, Rachel; Venn, Bernard

    2011-10-01

    Glycemic index (GI) testing is normally based on individual foods, whereas GIs for meals or diets are based on a formula using a weighted sum of the constituents. The accuracy with which the formula can predict a meal or diet GI is questionable. Our objective was to compare the GI of meals, obtained by using the formula and by using both measured food GI and published values, with directly measured meal GIs. The GIs of 7 foods were tested in 30 healthy people. The foods were combined into 3 meals, each of which provided 50 g available carbohydrate, including a staple (potato, rice, or spaghetti), vegetables, sauce, and pan-fried chicken. The mean (95% CI) meal GIs determined from individual food GI values and by direct measurement were as follows: potato meal [predicted, 63 (56, 70); measured, 53 (46, 62)], rice meal [predicted, 51 (45, 56); measured, 38 (33, 45)], and spaghetti meal [predicted, 54 (49, 60); measured, 38 (33, 44)]. The predicted meal GIs were all higher than the measured GIs (P < 0.001). The extent of the overestimation depended on the particular food, ie, 12, 15, and 19 GI units (or 22%, 40%, and 50%) for the potato, rice, and spaghetti meals, respectively. The formula overestimated the GI of the meals by between 22% and 50%. The use of published food values also overestimated the measured meal GIs. Investigators using the formula to calculate a meal or diet GI should be aware of limitations in the method. This trial is registered with the Australian and New Zealand Clinical Trials Registry as ACTRN12611000210976.

  19. Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

    International Nuclear Information System (INIS)

    Pfob, H.; Heinemann, G.

    1992-01-01

    Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

  20. Implant Monitoring Measurements On Ultra Shallow Implants Before And After Anneal Using Photomodulated Reflection And Junction Photovoltage Measurement Techniques

    Science.gov (United States)

    Tallian, M.; Pap, A.; Mocsar, K.; Somogyi, A.; Nadudvari, Gy.; Kosztka, D.; Pavelka, T.

    2011-01-01

    Ultra shallow junctions are becoming widely used in the micro- and nanoelectronic devices, and novel measurement methods are needed to monitor the manufacturing processes. Photomodulated Reflection measurements before anneal and Junction Photovoltage-based sheet resistance measurements after anneal are non-contact, nondestructive techniques suitable for characterizing both the implantation and the annealing process. Tests verify that these methods are consistent with each other and by using them together, defects originating in the implantation and anneal steps can be separated.

  1. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  2. Experimental study of ERT monitoring ability to measure solute dispersion.

    Science.gov (United States)

    Lekmine, Grégory; Pessel, Marc; Auradou, Harold

    2012-01-01

    This paper reports experimental measurements performed to test the ability of electrical resistivity tomography (ERT) imaging to provide quantitative information about transport parameters in porous media such as the dispersivity α, the mixing front velocity u, and the retardation factor R(f) associated with the sorption or trapping of the tracers in the pore structure. The flow experiments are performed in a homogeneous porous column placed between two vertical set of electrodes. Ionic and dyed tracers are injected from the bottom of the porous media over its full width. Under such condition, the mixing front is homogeneous in the transverse direction and shows an S-shape variation in the flow direction. The transport parameters are inferred from the variation of the concentration curves and are compared with data obtained from video analysis of the dyed tracer front. The variations of the transport parameters obtained from an inversion performed by the Gauss-Newton method applied on smoothness-constrained least-squares are studied in detail. While u and R(f) show a relatively small dependence on the inversion procedure, α is strongly dependent on the choice of the inversion parameters. Comparison with the video observations allows for the optimization of the parameters; these parameters are found to be robust with respect to changes in the flow condition and conductivity contrast. © 2011, The Author(s). Ground Water © 2011, National Ground Water Association.

  3. Monitoring method for an ambient Gamma exposure rate and its measurement analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mo Sung [Cheongju Univ., Cheongju (Korea, Republic of); Woo, Jong Kwan [University of Seoul, Seoul (Korea, Republic of)

    2006-12-15

    Daily and seasonal variations of the ambient gamma ray exposure rates were measured by using a pressurized ion chamber from January 2003 to December 2005 in the Cheongju Regional Radiation Monitoring Post and the patterns of the distributions were studied. The annual average of the daily variation of the exposure rate was {approx}0.17 {mu}R/h. The exposure rate was found to be maximum during 8:00 am to 9:00 am and minimum during 8:00 pm to 10:00 pm. For the annual data, the exposure rate was the minimum during the month of February. The exposure rate increased from February to mid-October (except during the period from May to July with no change) and decreased from October to February. The seasonal variation was found to be about 1 {mu}R/h. Most of the measured values (96%) of the exposure rates fell under the normal distribution with a deviation of less than 4.8% and the remaining 4% had large fluctuations caused mainly by the rainfalls.

  4. The value of pulmonary vessel CT measuring and calculating of relative ratio

    International Nuclear Information System (INIS)

    Ji Jiansong; Xu Xiaoxiong; Lv Suzhen; Zhao Zhongwei; Wang Zufei; Xu Min; Gong Jianping

    2004-01-01

    Objective: To evaluate value of CT measurement and calculation of vessels of isolate pig lung, by compare with measurement and calculation of resin cast of them. Methods: CT scanned and measured the four isolated pig lung which vessels were full with ABS liquid or self-solidification resin liquid, and calculate the relative ratio of superior/inferior order and vein/artery of same order. After resin cast were made, measure and calculate the same as CT did. Results: Second order of calculation of vein/artery of same order by the two method had statistic difference (P 0.05). Conclusion: CT has high value in calculation of the relative ratio of superior/inferior order

  5. Uniqueness of Gibbs measure for Potts model with countable set of spin values

    International Nuclear Information System (INIS)

    Ganikhodjaev, N.N.; Rozikov, U.A.

    2004-11-01

    We consider a nearest-neighbor Potts model with countable spin values 0,1,..., and non zero external field, on a Cayley tree of order k (with k+1 neighbors). We study translation-invariant 'splitting' Gibbs measures. We reduce the problem to the description of the solutions of some infinite system of equations. For any k≥1 and any fixed probability measure ν with ν(i)>0 on the set of all non negative integer numbers Φ={0,1,...} we show that the set of translation-invariant splitting Gibbs measures contains at most one point, independently on parameters of the Potts model with countable set of spin values on Cayley tree. Also we give a full description of the class of measures ν on Φ such that wit respect to each element of this class our infinite system of equations has unique solution {a i =1,2,...}, where a is an element of (0,1). (author)

  6. How Can Value-Added Measures Be Used for Teacher Improvement? What We Know Series: Value-Added Methods and Applications. Knowledge Brief 13

    Science.gov (United States)

    Loeb, Susanna

    2013-01-01

    The question for this brief is whether education leaders can use value-added measures as tools for improving schooling and, if so, how to do this. Districts, states, and schools can, at least in theory, generate gains in educational outcomes for students using value-added measures in three ways: creating information on effective programs, making…

  7. Non-Markovian stochastic Schroedinger equations: Generalization to real-valued noise using quantum-measurement theory

    International Nuclear Information System (INIS)

    Gambetta, Jay; Wiseman, H.M.

    2002-01-01

    Do stochastic Schroedinger equations, also known as unravelings, have a physical interpretation? In the Markovian limit, where the system on average obeys a master equation, the answer is yes. Markovian stochastic Schroedinger equations generate quantum trajectories for the system state conditioned on continuously monitoring the bath. For a given master equation, there are many different unravelings, corresponding to different sorts of measurement on the bath. In this paper we address the non-Markovian case, and in particular the sort of stochastic Schroedinger equation introduced by Strunz, Diosi, and Gisin [Phys. Rev. Lett. 82, 1801 (1999)]. Using a quantum-measurement theory approach, we rederive their unraveling that involves complex-valued Gaussian noise. We also derive an unraveling involving real-valued Gaussian noise. We show that in the Markovian limit, these two unravelings correspond to heterodyne and homodyne detection, respectively. Although we use quantum-measurement theory to define these unravelings, we conclude that the stochastic evolution of the system state is not a true quantum trajectory, as the identity of the state through time is a fiction

  8. Evaluation of Heat Flux Measurement as a New Process Analytical Technology Monitoring Tool in Freeze Drying.

    Science.gov (United States)

    Vollrath, Ilona; Pauli, Victoria; Friess, Wolfgang; Freitag, Angelika; Hawe, Andrea; Winter, Gerhard

    2017-05-01

    This study investigates the suitability of heat flux measurement as a new technique for monitoring product temperature and critical end points during freeze drying. The heat flux sensor is tightly mounted on the shelf and measures non-invasively (no contact with the product) the heat transferred from shelf to vial. Heat flux data were compared to comparative pressure measurement, thermocouple readings, and Karl Fischer titration as current state of the art monitoring techniques. The whole freeze drying process including freezing (both by ramp freezing and controlled nucleation) and primary and secondary drying was considered. We found that direct measurement of the transferred heat enables more insights into thermodynamics of the freezing process. Furthermore, a vial heat transfer coefficient can be calculated from heat flux data, which ultimately provides a non-invasive method to monitor product temperature throughout primary drying. The end point of primary drying determined by heat flux measurements was in accordance with the one defined by thermocouples. During secondary drying, heat flux measurements could not indicate the progress of drying as monitoring the residual moisture content. In conclusion, heat flux measurements are a promising new non-invasive tool for lyophilization process monitoring and development using energy transfer as a control parameter. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  9. A Value Measure for Public-Sector Enterprise Risk Management: A TSA Case Study.

    Science.gov (United States)

    Fletcher, Kenneth C; Abbas, Ali E

    2018-05-01

    This article presents a public value measure that can be used to aid executives in the public sector to better assess policy decisions and maximize value to the American people. Using Transportation Security Administration (TSA) programs as an example, we first identify the basic components of public value. We then propose a public value account to quantify the outcomes of various risk scenarios, and we determine the certain equivalent of several important TSA programs. We illustrate how this proposed measure can quantify the effects of two main challenges that government organizations face when conducting enterprise risk management: (1) short-term versus long-term incentives and (2) avoiding potential negative consequences even if they occur with low probability. Finally, we illustrate how this measure enables the use of various tools from decision analysis to be applied in government settings, such as stochastic dominance arguments and certain equivalent calculations. Regarding the TSA case study, our analysis demonstrates the value of continued expansion of the TSA trusted traveler initiative and increasing the background vetting for passengers who are afforded expedited security screening. © 2017 Society for Risk Analysis.

  10. Imaging and measurement of T1 value by NMR of low magnetic field

    International Nuclear Information System (INIS)

    Asai, Hideaki; Izawa, Akira; Furuse, Kazuhiro; Saoi, Katsuyoshi; Nagai, Masahiko.

    1983-01-01

    FONAR QED-80α having two operating mode: the anatomy mode to obtain an image of proton densities and the chemistry mode to measure T 1 value at a region of intenst, was used clinically. The strength of static magnetic field is 0.041T. 32 cases, 18 healthy volunteers and 14 patients were studied. In proton density imaging, high proton density organs such as skin were imaged bright, and low proton density organs such as bones and flowing blood were imaged dark. The merits of NMR imaging are no artifacts caused by bones and air. However, NMR image is required long time for measurement and the image of NMR is unsharp than that of X-ray CT. Concerning with T 1 value, cerebral and cerebellar gray matter had longer T 1 's than that of white matter. Pathological lesions, such as tumor and/or infarct, had also longer T 1 values than these of normal tissue. The value of T 1 was thought to be applicable clinically except for some problems, such as measuring T 1 value of large extent. No side effects were found during and after examinations. (author)

  11. Prognostic and diagnostic value of EEG signal coupling measures in coma.

    Science.gov (United States)

    Zubler, Frederic; Koenig, Christa; Steimer, Andreas; Jakob, Stephan M; Schindler, Kaspar A; Gast, Heidemarie

    2016-08-01

    Our aim was to assess the diagnostic and predictive value of several quantitative EEG (qEEG) analysis methods in comatose patients. In 79 patients, coupling between EEG signals on the left-right (inter-hemispheric) axis and on the anterior-posterior (intra-hemispheric) axis was measured with four synchronization measures: relative delta power asymmetry, cross-correlation, symbolic mutual information and transfer entropy directionality. Results were compared with etiology of coma and clinical outcome. Using cross-validation, the predictive value of measure combinations was assessed with a Bayes classifier with mixture of Gaussians. Five of eight measures showed a statistically significant difference between patients grouped according to outcome; one measure revealed differences in patients grouped according to the etiology. Interestingly, a high level of synchrony between the left and right hemisphere was associated with mortality on intensive care unit, whereas higher synchrony between anterior and posterior brain regions was associated with survival. The combination with the best predictive value reached an area-under the curve of 0.875 (for patients with post anoxic encephalopathy: 0.946). EEG synchronization measures can contribute to clinical assessment, and provide new approaches for understanding the pathophysiology of coma. Prognostication in coma remains a challenging task. qEEG could improve current multi-modal approaches. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Incidence and localizing value of vertigo and dizziness in patients with epilepsy: Video-EEG monitoring study.

    Science.gov (United States)

    Kim, Dong Wook; Sunwoo, Jun-Sang; Lee, Sang Kun

    2016-10-01

    Vertigo and dizziness are common neurological complaints that have long been associated with epilepsy. However, studies of patients with epileptic vertigo or dizziness with concurrent EEG monitoring are scarce. We performed the present study to investigate the incidence and localizing value of vertigo and dizziness in patients with epilepsy who had confirmation of EEG changes via video-EEG monitoring. Data of aura and clinical seizure episodes of 831 consecutive patients who underwent video-EEG monitoring were analyzed retrospectively. Out of 831 patients, 40 patients (4.8%) experienced vertigo or dizziness as aura (mean age, 32.8±11.8years), all of whom had partial seizures. Eight had mesial temporal, 20 had lateral temporal, four had frontal, one had parietal, and seven had occipital lobe onset seizures. An intracranial EEG with cortical stimulation study was performed in seven patients, and the area of stimulation-induced vertigo or dizziness coincided with the ictal onset area in only one patient. Our study showed that vertigo or dizziness is a common aura in patients with epilepsy, and that the temporal lobe is the most frequent ictal onset area in these patients. However, it can be suggested that the symptomatogenic area in patients with epileptic vertigo and dizziness may not coincide with the ictal onset area. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Cell-associated HIV DNA measured early during infection has prognostic value independent of serum HIV RNA measured concomitantly

    DEFF Research Database (Denmark)

    Katzenstein, Terese L; Oliveri, Roberto S; Benfield, Thomas

    2002-01-01

    Using data from the Danish AIDS Cohort of HIV-infected homosexual men established in the 1980s, the prognostic value of early HIV DNA loads was evaluated. In addition to DNA measurements, concomitant serum HIV RNA levels, CD4 cell counts and CCR5 genotypes were determined. The patients were divided...... into 3 groups, according to whether their cell-associated HIV DNA load was or = 2,500 DNA copies/10(6) peripheral blood mononuclear cells. Clinical progression rates differed significantly between the groups (p value independent...... of serum HIV RNA (p value. Patients heterozygous for the CCR5 delta 32 allele had significantly lower HIV DNA loads than those homozygous for the normal allele (p

  14. Accurate Estimation of Low Fundamental Frequencies from Real-Valued Measurements

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2013-01-01

    In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason for this is that the......In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason...... for this is that they employ asymptotic approximations that are violated when the harmonics are not well-separated in frequency, something that happens when the observed signal is real-valued and the fundamental frequency is low. To mitigate this, we analyze the problem and present some exact fundamental frequency estimators...

  15. Measuring the Value of Succession Planning and Management: A Qualitative Study of Multinational Companies

    Science.gov (United States)

    Kim, Yeonsoo

    2010-01-01

    This article proposes a model for planning and operating an effective succession planning and management (SP&M) program and measuring its value. The nature of the research is exploratory, following a qualitative approach using in-depth interviews. Representatives of multinational companies interviewed for this study revealed that succession…

  16. Normal values for bone mineral content measured by dual photon absorptiometry in children

    International Nuclear Information System (INIS)

    Tison, F.; Lecouffe, P.; Rousseau, J.; Marchandise, X.; Ythier, H.

    1990-01-01

    The results of dual photon absorptiometry measurements in 43 normal children are analyzed. Results were correlated with age, body weight, and stature. Reference stature-specific values for bone mineral content in children are proposed. Furthermore, the results show that mineralization continues beyond the end of statural growth [fr

  17. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers

    NARCIS (Netherlands)

    Haftka, Joris J H; Scherpenisse, Peter; Oetter, G??nter; Hodges, Geoff; Eadsforth, Charles V.; Kotthoff, Matthias; Hermens, Joop L M

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibres were used in the present study to measure CMC values of twelve nonionic, anionic, cationic and zwitterionic surfactants. The SPME derived CMC

  18. The predictive value of different infant attachment measures for socioemotional development at age 5 years

    NARCIS (Netherlands)

    Smeekens, S.; Riksen-Walraven, J.M.A.; Bakel, H.J.A. van

    2009-01-01

    The predictive value of different infant attachment measures was examined in a community-based sample of 111 healthy children (59 boys, 52 girls). Two procedures to assess infant attachment, the Attachment Q-Set (applied on a relatively short observation period) and a shortened version of the

  19. Determination of temperature dependant viscosity values of lubricants via simultaneous measurements of refractive index

    International Nuclear Information System (INIS)

    Yaltkaya, S.

    2005-01-01

    Viscosity is one of the most important parameter in rheological and tribological properties of fluids. The objective of this study is to obtain the viscosity values from the simultaneous refractive-index measurements of lubricants, simply by dipping the fiber-optic probe into the oil to be measured. Due to the fact that these parameters are temperature dependent, within the interval under consideration, oil heated up steadily while measuring the viscosity and refractive index at the same time. The refractive index sensor, the digital viscometer and the thermometer were connected to a PC via an analog to digital converter and the values were acquired at the same time. The fiber optic refractive index sensor has been designed in our laboratory. By utilising Fresnel's fundamental reflection law, the intensity of reflected light from boundary surface (optic fiber core-motor oil) was measured at 660 nm wavelength and then refractive index of the oil was calculated. The derived refractive index values were converted viscosity values that acquired by using the calibration equation. The viscometer, used during the study, was the rotational Brookfield type

  20. Value-Added Measures in Education: What Every Educator Needs to Know

    Science.gov (United States)

    Harris, Douglas N.

    2011-01-01

    In "Value-Added Measures in Education", Douglas N. Harris takes on one of the most hotly debated topics in education. Drawing on his extensive work with schools and districts, he sets out to help educators and policymakers understand this innovative approach to assessment and the issues associated with its use. Written in straightforward language…

  1. Dispositional resistance to change: Measurement equivalence and the link to personal values across 17 nations

    Czech Academy of Sciences Publication Activity Database

    Oreg, S.; Bayazit, M.; Vakola, M.; Arciniega, L.; Armenakis, A.; Barkauskiene, R.; Bozionelos, N.; Ferič, I.; Fujimoto, Y.; Gonzáles, L.; Han, J.; Hetland, H.; Hřebíčková, Martina; Jimmieson, N.; Kordačová, J.; Kotrla Topič, M.; Mitsuhashi, H.; Mlacić, B.; Ohly, S.; Saksvik, I.; Saksvik, P.O.; van Dam, K.

    2008-01-01

    Roč. 93, č. 4 (2008), s. 935-944 ISSN 0021-9010 R&D Projects: GA AV ČR IAA700250702 Institutional research plan: CEZ:AV0Z70250504 Keywords : resistance to change * personal values * measurement equivalence Subject RIV: AN - Psychology Impact factor: 3.769, year: 2008

  2. Estimating values for the moisture source load and buffering capacities from indoor climate measurements

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2008-01-01

    The objective of this study is to investigate the potential for estimating values for the total size of human induced moisture source load and the total buffering (moisture storage) capacity of the interior objects with the use of relatively simple measurements and the use of heat, air, and moisture

  3. Effects of caffeine on fractional flow reserve values measured using intravenous adenosine triphosphate.

    Science.gov (United States)

    Nakayama, Masafumi; Chikamori, Taishiro; Uchiyama, Takashi; Kimura, Yo; Hijikata, Nobuhiro; Ito, Ryosuke; Yuhara, Mikio; Sato, Hideaki; Kobori, Yuichi; Yamashina, Akira

    2018-04-01

    We investigated the effects of caffeine intake on fractional flow reserve (FFR) values measured using intravenous adenosine triphosphate (ATP) before cardiac catheterization. Caffeine is a competitive antagonist for adenosine receptors; however, it is unclear whether this antagonism affects FFR values. Patients were evenly randomized into 2 groups preceding the FFR study. In the caffeine group (n = 15), participants were given coffee containing 222 mg of caffeine 2 h before the catheterization. In the non-caffeine group (n = 15), participants were instructed not to take any caffeine-containing drinks or foods for at least 12 h before the catheterization. FFR was performed in patients with more than intermediate coronary stenosis using the intravenous infusion of ATP at 140 μg/kg/min (normal dose) and 170 μg/kg/min (high dose), and the intracoronary infusion of papaverine. FFR was followed for 30 s after maximal hyperemia. In the non-caffeine group, the FFR values measured with ATP infusion were not significantly different from those measured with papaverine infusion. However, in the caffeine group, the FFR values were significantly higher after ATP infusion than after papaverine infusion (P = 0.002 and P = 0.007, at normal and high dose ATP vs. papaverine, respectively). FFR values with ATP infusion were significantly increased 30 s after maximal hyperemia (P = 0.001 and P < 0.001 for normal and high dose ATP, respectively). The stability of the FFR values using papaverine showed no significant difference between the 2 groups. Caffeine intake before the FFR study affected FFR values and their stability. These effects could not be reversed by an increased ATP dose.

  4. We do not know what we do not know: innovative approaches to value measurement.

    Science.gov (United States)

    Laviana, Aaron A; Resnick, Matthew J

    2018-07-01

    Over the past several years, there has been an increasing focus on improving the 'value' of healthcare delivered, defined as the ratio of clinical outcomes to the costs incurred to achieve them. The former U.S. Secretary of Health and Human Services Sylvia Burwell announced in 2015 that the majority of healthcare payments in the Medicare and Medicaid programmes will align with value by 2018. Although this has yet to fully mature, numerous health systems have restructured with a goal of improving the value of care delivered to their populations. Nevertheless, there remain important unanswered questions regarding how we measure value in the current U.S. healthcare system. The purpose of this review is to highlight innovations that are not only making it easier to measure value but also to improve care from the patient, provider and healthcare system perspectives. Behavioural start-ups and the introduction of relatively inexpensive health coaches are starting to permeate the healthcare landscape. These coaches are the consumers' advocate, acting as the quarterback of an extended care team in order to optimize health. Furthermore, time-driven activity-based costing has allowed us to understand costs on a more granular level, and novel tracking software may further automate these costing algorithms in order to better facilitate their dissemination. We must all work to enable new models of care that improve value by incentivizing individuals, payers and providers to improve health, rather than treat the disease after it manifests. We must also continue to improve the efficiency of healthcare delivery largely through improvements in value measurement.

  5. Error in the measurement of the Telector monitor, model 6112B (analogic); Error de medicion del monitor Telector, modelo 6112B (analogico)

    Energy Technology Data Exchange (ETDEWEB)

    Cruz E, P.; Sanchez R, G.H.; Torres B, M.A.; Martinez, R.F. [ININ, 52750 La Marquesa, Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: pce@nuclear.inin.mx

    2007-07-01

    This monitor is a portable equipment used with radiological protection ends in many areas where use of radioactive material is made, since account with a telescopic bar with two Geiger Mueller tubes (GM) to measure gamma radiation. The maker in his specifications indicates that the equipment is able to measure from 0.1 R/hr up to 1000 R/hr and their response doesn't depend on the energy in the interval of 300 keV to 3 MeV. However, personal of the Electronic Systems department carrying out tests in the Secondary Laboratory of Dosimetric Calibration (LSCD) of the ININ, it found that this monitor really presents an energy dependence for the energies of {sup 60}Co, in the scale of 2 R/hr. With base in an analysis of the equipment and the two GM detectors that it uses, was found that the origin of the problem is the point of saturation of the detector that uses for this scale, which coincides with the maximum measurement value that is of 2 R/hr. This flaw it can be solved using the detector that operates with the high scales, for which is required to make a modification to the electronic circuit in the part of the switch that selects the detector type. (Author)

  6. A process for selecting ecological indicators for application in monitoring impacts to Air Quality Related Values (AQRVs) from atmospheric pollutants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    White, G.J.; Breckenridge, R.P.

    1997-01-01

    Section 160 of the Clean Air Act (CAA) calls for measures be taken {open_quotes}to preserve, protect, and enhance air quality in national parks, national wilderness areas, national monuments, national seashores, and other areas of special national or regional natural, recreational, scenic, or historic value.{close_quotes} Pursuant to this, stringent requirement have been established for {open_quotes}Class I{close_quotes} areas, which include most National Parks and Wilderness Areas. Federal Land Managers (FLMs) are charged with the task of carrying out these requirements through the identification of air quality related values (AQRVs) that are potentially at risk from atmospheric pollutants. This is a complex task, the success of which is dependent on the gathering of information on a wide variety of factors that contribute to the potential for impacting resources in Class I areas. Further complicating the issue is the diversity of ecological systems found in Class I areas. There is a critical need for the development of monitoring programs to assess the status of AQRVs in Class I areas with respect to impacts caused by atmospheric pollutants. These monitoring programs must be based on the measurement of a carefully selected suite of key physical, chemical, and biological parameters that serve as indicators of the status of the ecosystems found in Class I areas. Such programs must be both scientifically-based and cost-effective, and must provide the data necessary for FLMs to make objective, defensible decisions. This document summarizes a method for developing AQRV monitoring programs in Class I areas.

  7. Humans as Sensors: Assessing the Information Value of Qualitative Farmer's Crop Condition Surveys for Crop Yield Monitoring and Forecasting

    Science.gov (United States)

    Beguería, S.

    2017-12-01

    While large efforts are devoted to developing crop status monitoring and yield forecasting systems trough the use of Earth observation data (mostly remotely sensed satellite imagery) and observational and modeled weather data, here we focus on the information value of qualitative data on crop status from direct observations made by humans. This kind of data has a high value as it reflects the expert opinion of individuals directly involved in the development of the crop. However, they have issues that prevent their direct use in crop monitoring and yield forecasting systems, such as their non-spatially explicit nature, or most importantly their qualitative nature. Indeed, while the human brain is good at categorizing the status of physical systems in terms of qualitative scales (`very good', `good', `fair', etcetera), it has difficulties in quantifying it in physical units. This has prevented the incorporation of this kind of data into systems that make extensive use of numerical information. Here we show an example of using qualitative crop condition data to estimate yields of the most important crops in the US early in the season. We use USDA weekly crop condition reports, which are based on a sample of thousands of reporters including mostly farmers and people in direct contact with them. These reporters provide subjective evaluations of crop conditions, in a scale including five levels ranging from `very poor' to `excellent'. The USDA report indicates, for each state, the proportion of reporters fort each condition level. We show how is it possible to model the underlying non-observed quantitative variable that reflects the crop status on each state, and how this model is consistent across states and years. Furthermore, we show how this information can be used to monitor the status of the crops and to produce yield forecasts early in the season. Finally, we discuss approaches for blending this information source with other, more classical earth data sources

  8. Supplementary measurements for air monitoring under NOVANA - Benzene and PAH; Supplerende maalinger til luftovervaagning under NOVANA - benzen og PAH

    Energy Technology Data Exchange (ETDEWEB)

    Ellermann, T.; Klenoe Noejgaard, J.; Bossi, R.

    2011-10-15

    The report presents results from a project carried out for the Danish Environmental Protection Agency. The aim of the project was to carry out several measuring campaigns in order to be able to better assess the monitoring needs for PAH and benzene in relation to EU's air quality directives. The results show that the mean concentrations of benzene are almost at the same level in Denmark's four largest cities, and that the concentrations are both below the threshold value (5mug/m3) as well as below the lower assessment threshold (2mug/m3). The report presents a method for objectively estimation the benzene concentration based on measurements of CO. The method can be applied to fulfil the monitoring need for benzene in those zones where no measurements of benzene are made. Measurements of PAH, especially benzo(a)pyrene, have been made during 12 months in the period 2010-2011 in an area with many wood burning furnaces are used (the town Jyllinge). The concentrations of benzo(a)pyrene in Jyllinge is almost three times higher than in the street H.C. Andersens Boulevard in Copenhagen. The concentrations of benzo(a)pyrene in Jylllinge are 0,6 ng/m3, which corresponds to the upper assessment threshold (0,6 ng/m3) and is 40% below the measuring value (1 ng/m3). On this basis, there is a need for re-evaluating the monitoring of PAH in the sub-programme for air under NOVANA. Measurements of PM{sub 10} showed that the levels in the towns Jyllinge, Lille Valby/Risoe and at the H.C. Oersted Institute in Copenhagen are all at about 20-22 mug/m3. (LN)

  9. An improved potential drop method for measuring and monitoring defects in structures

    International Nuclear Information System (INIS)

    Oppermann, W.; Keller, H.P.

    1991-01-01

    In its advanced form, the direct-current potential probe measuring technique is a reliable and relatively exact procedure for measuring and monitoring surface defects. In addition, there is the possibility - important for practical purposes - of measuring cracks at the inaccessible side of a component part. The improved accuracy, in particular with regard to short defects, is based on advanced measuring techniques and calibration curves determined at the electrolytical tank. (orig./DG) [de

  10. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery.

    Directory of Open Access Journals (Sweden)

    George Garas

    Full Text Available Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations.Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus® was performed (1974-2014. The virality of each cascade was measured as was innovation value (measured by the innovation index derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample-NIS®.Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width were found to correlate closely with the ranking by innovation value (Spearman's rank correlation coefficient = 0.758 (p = 0.01, 0.782 (p = 0.008, 0.624 (p = 0.05, respectively which in turn matches the ranking based on real world big data from the NIS® (Spearman's coefficient = 0.673;p = 0.033.Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different specialties. The novel surgical innovation metrics

  11. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery.

    Science.gov (United States)

    Garas, George; Cingolani, Isabella; Panzarasa, Pietro; Darzi, Ara; Athanasiou, Thanos

    2017-01-01

    Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations. Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus®) was performed (1974-2014). The virality of each cascade was measured as was innovation value (measured by the innovation index) derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample-NIS®). Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width) were found to correlate closely with the ranking by innovation value (Spearman's rank correlation coefficient = 0.758 (p = 0.01), 0.782 (p = 0.008), 0.624 (p = 0.05), respectively) which in turn matches the ranking based on real world big data from the NIS® (Spearman's coefficient = 0.673;p = 0.033). Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different specialties. The novel surgical innovation metrics developed may

  12. A program for monitor unit calculation for high energy photon beams in isocentric condition based on measured data

    International Nuclear Information System (INIS)

    Gesheva-Atanasova, N.

    2008-01-01

    The aim of this study is: 1) to propose a procedure and a program for monitor unit calculation for radiation therapy with high energy photon beams, based on data measured by author; 2) to compare this data with published one and 3) to evaluate the precision of the monitor unit calculation program. From this study it could be concluded that, we reproduced with a good agreement the published data, except the TPR values for dept up to 5 cm. The measured relative weight of upper and lower jaws - parameter A was dramatically different from the published data, but perfectly described the collimator exchange effect for our treatment machine. No difference was found between the head scatter ratios, measured in a mini phantom and those measured with a proper brass buildup cap. Our monitor unit calculation program was found to be reliable and it can be applied for check up of the patient's plans for irradiation with high energy photon beams and for some fast calculations. Because of the identity in the construction, design and characteristics of the Siemens accelerators, and the agreement with the published data for the same beam qualities, we hope that most of our experimental data and this program can be used after verification in other hospitals

  13. Monitor of Energetic Saving. Final measurements; Monitor VoortVarend Besparen. Eindmeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-05-15

    In 2007, the Dutch Ministry of Waterways and Public Works (currently the Ministry of Infrastructure and Environment) launched the multi-annual plan 'Voortvarend Besparen 2007-2010' (Energetic Saving) that aims to stimulate captains of barges into more energy efficient sailing behavior. The program aims to encourage energy efficient operation of ships, resulting in a fuel saving and a 5% reduction in CO2 emissions in inland shipping in 2010 compared to 2007. In the final measurement, questionnaires were sent to the barge skippers to find out if the inland shipping sector succeeded in realizing the target and to examine to what extent the Energetic Saving program contributed to the CO2 reduction. [Dutch] In 2007 heeft het Ministerie van Verkeer en Waterstaat (nu het Ministerie van Infrastructuur en Milieu) het startsein gegeven voor het meerjarenprogramma VoortVarend Besparen (2007 - 2010) met als doel schippers te stimuleren tot energie-efficienter vaargedrag. Het programma dient energie-efficienter vaargedrag te stimuleren resulterend in een brandstofbesparing en een 5% reductie van CO2 emissies in de binnenvaartsector in 2010 ten opzichte van 2007. In de eindmeting is door middel van enquetes onder binnenvaartschippers onderzocht of de binnenvaartsector deze doelstelling heeft gehaald, en in welke mate het VoortVarend Besparen programma heeft bijgedragen aan deze CO2-reductie.

  14. Comparison of LOFT zero power physics testing measurement results with predicted values

    International Nuclear Information System (INIS)

    Rushton, B.L.; Howe, T.M.

    1978-01-01

    The results of zero power physics testing measurements in LOFT have been evaluated to assess the adequacy of the physics data used in the safety analyses performed for the LOFT FSAR and Technical Specifications. Comparisons of measured data with computed data were made for control rod worths, temperature coefficients, boron worths, and pressure coefficients. Measured boron concentrations at exact critical points were compared with predicted concentrations. Based on these comparisons, the reactivity parameter values used in the LOFT safety analyses were assessed for conservatism

  15. Two-qubit Bell inequality for which positive operator-valued measurements are relevant

    International Nuclear Information System (INIS)

    Vertesi, T.; Bene, E.

    2010-01-01

    A bipartite Bell inequality is derived which is maximally violated on the two-qubit state space if measurements describable by positive operator valued measure (POVM) elements are allowed, rather than restricting the possible measurements to projective ones. In particular, the presented Bell inequality requires POVMs in order to be maximally violated by a maximally entangled two-qubit state. This answers a question raised by N. Gisin [in Quantum Reality, Relativistic Causality, and Closing the Epistemic Circle: Essays in Honour of Abner Shimony, edited by W. C. Myrvold and J. Christian (Springer, The Netherlands, 2009), pp. 125-138].

  16. Behavioral economic measures of alcohol reward value as problem severity indicators in college students.

    Science.gov (United States)

    Skidmore, Jessica R; Murphy, James G; Martens, Matthew P

    2014-06-01

    The aims of the current study were to examine the associations among behavioral economic measures of alcohol value derived from 3 distinct measurement approaches, and to evaluate their respective relations with traditional indicators of alcohol problem severity in college drinkers. Five behavioral economic metrics were derived from hypothetical demand curves that quantify reward value by plotting consumption and expenditures as a function of price, another metric measured proportional behavioral allocation and enjoyment related to alcohol versus other activities, and a final metric measured relative discretionary expenditures on alcohol (RDEA). The sample included 207 heavy-drinking college students (53% female) who were recruited through an on-campus health center or university courses. Factor analysis revealed that the alcohol valuation construct comprises 2 factors: 1 factor that reflects participants' levels of alcohol price sensitivity (demand persistence), and a second factor that reflects participants' maximum consumption and monetary and behavioral allocation toward alcohol (amplitude of demand). The demand persistence and behavioral allocation metrics demonstrated the strongest and most consistent multivariate relations with alcohol-related problems, even when controlling for other well-established predictors. The results suggest that behavioral economic indices of reward value show meaningful relations with alcohol problem severity in young adults. Despite the presence of some gender differences, these measures appear to be useful problem indicators for men and women. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  17. The system of the measurement of reactor power and the monitoring of core power distribution

    International Nuclear Information System (INIS)

    Li Xianfeng

    1999-01-01

    The author mainly describes the measurement of the reactor power and the monitoring of the core power distribution in DAYA BAY nuclear power plant, introduces the calibration for the measurement system. Ex-core nuclear instrumentation system (RPN) and LOCA surveillance system (LSS) are the most important system for the object. they perform the measurement of the reactor power and the monitoring of the core power distribution on-line and timely. They also play the important roles in the reactor control and the reactor protection. For the same purpose there are test instrumentation system (KME) and in-core instrumentation system (RIC). All of them work together ensuring the exact measurement and effective monitoring, ensuring the safety of the reactor power plant

  18. A new measurement method for electrode gain in an orthogonally symmetric beam position monitor

    International Nuclear Information System (INIS)

    Zou Junying; Wu Fangfang; Yang Yongliang; Sun Baogen; Zhou Zeran; Luo Qing; Lu Ping; Xu Hongliang

    2014-01-01

    The new beam position monitor (BPM) system of the injector at the upgrade project of the Hefei Light Source (HLS Ⅱ) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismaching tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%. (authors)

  19. A quantum inspired model of radar range and range-rate measurements with applications to weak value measurements

    Science.gov (United States)

    Escalante, George

    2017-05-01

    Weak Value Measurements (WVMs) with pre- and post-selected quantum mechanical ensembles were proposed by Aharonov, Albert, and Vaidman in 1988 and have found numerous applications in both theoretical and applied physics. In the field of precision metrology, WVM techniques have been demonstrated and proven valuable as a means to shift, amplify, and detect signals and to make precise measurements of small effects in both quantum and classical systems, including: particle spin, the Spin-Hall effect of light, optical beam deflections, frequency shifts, field gradients, and many others. In principal, WVM amplification techniques are also possible in radar and could be a valuable tool for precision measurements. However, relatively limited research has been done in this area. This article presents a quantum-inspired model of radar range and range-rate measurements of arbitrary strength, including standard and pre- and post-selected measurements. The model is used to extend WVM amplification theory to radar, with the receive filter performing the post-selection role. It is shown that the description of range and range-rate measurements based on the quantum-mechanical measurement model and formalism produces the same results as the conventional approach used in radar based on signal processing and filtering of the reflected signal at the radar receiver. Numerical simulation results using simple point scatterrer configurations are presented, applying the quantum-inspired model of radar range and range-rate measurements that occur in the weak measurement regime. Potential applications and benefits of the quantum inspired approach to radar measurements are presented, including improved range and Doppler measurement resolution.

  20. Long-term environmental monitoring for assessment of change: measurement inconsistencies over time and potential solutions.

    Science.gov (United States)

    Ellingsen, Kari E; Yoccoz, Nigel G; Tveraa, Torkild; Hewitt, Judi E; Thrush, Simon F

    2017-10-30

    The importance of long-term environmental monitoring and research for detecting and understanding changes in ecosystems and human impacts on natural systems is widely acknowledged. Over the last decades, a number of critical components for successful long-term monitoring have been identified. One basic component is quality assurance/quality control protocols to ensure consistency and comparability of data. In Norway, the authorities require environmental monitoring of the impacts of the offshore petroleum industry on the Norwegian continental shelf, and in 1996, a large-scale regional environmental monitoring program was established. As a case study, we used a sub-set of data from this monitoring to explore concepts regarding best practices for long-term environmental monitoring. Specifically, we examined data from physical and chemical sediment samples and benthic macroinvertebrate assemblages from 11 stations from six sampling occasions during the period 1996-2011. Despite the established quality assessment and quality control protocols for this monitoring program, we identified several data challenges, such as missing values and outliers, discrepancies in variable and station names, changes in procedures without calibration, and different taxonomic resolution. Furthermore, we show that the use of different laboratories over time makes it difficult to draw conclusions with regard to some of the observed changes. We offer recommendations to facilitate comparison of data over time. We also present a new procedure to handle different taxonomic resolution, so valuable historical data is not discarded. These topics have a broader relevance and application than for our case study.

  1. Real-time monitoring of emissions with traffic data, simulation and air quality measurements

    NARCIS (Netherlands)

    Klunder, G.A.; Wilmink, I.R.

    2009-01-01

    This paper investigates the possibility to decide when to apply a (dynamic) traffic management measure to improve the air quality or reduce CO2 emissions, based on a limited set of (measured) data. It is expected that a combination of monitoring and modeling is needed for reliable air quality

  2. Pneumothorax monitoring by remittance measurement: Comparison between experimental model and animal studies

    NARCIS (Netherlands)

    Beek, J. F.; Menovsky, T.; van Straaten, H. L.; Sterenborg, H. J.; Koppe, J. G.; van Gemert, M. J.

    1999-01-01

    Pneumothorax monitoring by remittance measurement in neonatology is investigated using model experiments. The results are compared to previous animal experiments. A multifibre probe is used to measure the change in remittance at 632.8 nm and 790 nm as a function of the thickness of a layer of air

  3. Practical Field Calibration of Portable Monitors for Mobile Measurements of Multiple Air Pollutants

    Directory of Open Access Journals (Sweden)

    Chun Lin

    2017-11-01

    Full Text Available To reduce inaccuracies in the measurement of air pollutants by portable monitors it is necessary to establish quantitative calibration relationships against their respective reference analyser. This is usually done under controlled laboratory conditions or one-off static co-location alongside a reference analyser in the field, neither of which may adequately represent the extended use of portable monitors in exposure assessment research. To address this, we investigated ways of establishing and evaluating portable monitor calibration relationships from repeated intermittent deployment cycles over an extended period involving stationary deployment at a reference site, mobile monitoring, and completely switched off. We evaluated four types of portable monitors: Aeroqual Ltd. (Auckland, New Zealand S500 O3 metal oxide and S500 NO2 electrochemical; RTI (Berkeley, CA, USA MicroPEM PM2.5; and, AethLabs (San Francisco, CA, USA AE51 black carbon (BC. Innovations in our study included: (i comparison of calibrations derived from the individual co-locations of a portable monitor against its reference analyser or from all the co-location periods combined into a single dataset; and, (ii evaluation of calibrated monitor estimates during transient measurements with the portable monitor close to its reference analyser at separate times from the stationary co-location calibration periods. Within the ~7 month duration of the study, ‘combined’ calibration relationships for O3, PM2.5, and BC monitors from all co-locations agreed more closely on average with reference measurements than ‘individual’ calibration relationships from co-location deployment nearest in time to transient deployment periods. ‘Individual’ calibrations relationships were sometimes substantially unrepresentative of the ‘combined’ relationships. Reduced quantitative consistency in field calibration relationships for the PM2.5 monitors may have resulted from generally low PM2

  4. Reference values for physical performance measures in the aging working population.

    Science.gov (United States)

    Cote, Mark P; Kenny, Anne; Dussetschleger, Jeffrey; Farr, Dana; Chaurasia, Ashok; Cherniack, Martin

    2014-02-01

    The aim of this study was to determine reference physical performance values in older aging workers. Cross-sectional physical performance measures were collected for 736 manufacturing workers to assess effects of work and nonwork factors on age-related changes in musculoskeletal function and health. Participants underwent surveys and physical testing that included bioelectrical impedance analysis, range-of-motion measures, exercise testing, and dynamic assessment. Physical characteristics, such as blood pressure and body fat percentage, were comparable to published values. Dynamic and range-of-motion measurements differed from published normative results. Women had age-related decreases in cervical extension and lateral rotation. Older men had better spinal flexion than expected. Predicted age-related decline in lower-extremity strength and shoulder strength in women was not seen. Men declined in handgrip, lower-extremity strength, and knee extension strength, but not trunk strength, across age groups. There was no appreciable decline in muscle fatigue at the trunk, shoulder, and knee with aging for either gender, except for the youngest age group of women. Normative values may underestimate physical performance in "healthy" older workers, thereby underappreciating declines in less healthy older workers. Work may be preservative of function for a large group of selected individuals. A "healthy worker effect" may be greater for musculoskeletal disease and function than for heart disease and mortality. Clinicians and researchers studying musculoskeletal function in older workers can use a more specific set of reference values.

  5. Measuring the value of groundwater and other forms of natural capital

    Science.gov (United States)

    Fenichel, Eli P.; Abbott, Joshua K.; Bayham, Jude; Boone, Whitney; Haacker, Erin M. K.; Pfeiffer, Lisa

    2016-01-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996−2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996–2005. This annual loss in wealth is approximately equal to the state’s 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas’ depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets. PMID:26858431

  6. International Target Values 2010 for Measurement Uncertainties in Safeguarding Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, M.; Penkin, M.; Norman, C.; Balsley, S. [IAEA, Vienna (Australia); others, and

    2012-12-15

    This issue of the International Target Values (ITVs) represents the sixth revision, following the first release of such tables issued in 1979 by the ESARDA/WGDA. The ITVs are uncertainties to be considered in judging the reliability of analytical techniques applied to industrial nuclear and fissile material, which are subject to safeguards verification. The tabulated values represent estimates of the 'state of the practice' which should be achievable under routine measurement conditions. The most recent standard conventions in representing uncertainty have been considered, while maintaining a format that allows comparison with the previous releases of the ITVs. The present report explains why target values are needed, how the concept evolved and how they relate to the operator's and inspector's measurement systems. The ITVs-2010 are intended to be used by plant operators and safeguards organizations, as a reference of the quality of measurements achievable in nuclear material accountancy, and for planning purposes. The report suggests that the use of ITVs can be beneficial for statistical inferences regarding the significance of operator-inspector differences whenever valid performance values are not available.

  7. Measuring the value of groundwater and other forms of natural capital.

    Science.gov (United States)

    Fenichel, Eli P; Abbott, Joshua K; Bayham, Jude; Boone, Whitney; Haacker, Erin M K; Pfeiffer, Lisa

    2016-03-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996-2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996-2005. This annual loss in wealth is approximately equal to the state's 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas' depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets.

  8. MD 2408: Study of Schottky Monitors for Q' Measurement at Injection

    CERN Document Server

    Tydecks, Tobias; Levens, Tom; Wendt, Manfred; Wenninger, Jorg; CERN. Geneva. ATS Department

    2018-01-01

    The Schottky monitors installed at the LHC enable the detection of Schottky noise of the two circulating proton / ion beams. From Schottky noise, beam parameters like tune, chromaticity, and relative emittance, can be extracted in a non-destructive and purely parasitic method of measurement. The primary goal of this MD was to study the Schottky monitors capability to reliably and accurately determine the beam chromaticities at injection energy. Furthermore, the possibility to track the beam emittance has been investigated.

  9. The cerebral blood flow measurement without absolute input function value for PET O-15 injection method

    International Nuclear Information System (INIS)

    Matsuda, Tadashige

    2004-01-01

    This paper shows the method of the measurement for the region of interest's (ROI's) cerebral blood flow (CBF) using PET data and the input function without the absolute density value of the radio activity. The value of the input function and the output function are fixed from the clinical data by regression analysis. The input function and the output function are transformed by the Fourier transform. The transfer function of the differential equation of the compartment model is got by these Fourier transforms. The CBF can be estimated by the transfer function regression analysis. Results are compared between the proposal and conventional methods. (author)

  10. Assessment of Measurement Uncertainty Values of the Scandium Determination in Marine Sediment

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2005-01-01

    The result value of testing is meaningless if it isn't completed with uncertainty value. So that with the analysis result Sc in the marine sediment sample. It was assessed the uncertainty measurement of Sc analysis in marine sediment. The experiment was done in AAN Serpong laboratory. The result of calculation uncertainty on Sc analysis showed that the uncertainty components come from: preparation of sample and standard/comparator, purity of standard, counting statistics (sample and standard), repeatability, nuclear data and decay correction. The assessment on uncertainty must be done for the analysis of others elements, because each elements has difference nuclear and physical properties. (author)

  11. Measuring the financial value of brand as an intangible asset of an enterprise

    Directory of Open Access Journals (Sweden)

    Popović Ana

    2015-01-01

    Full Text Available The purpose of this paper is to explore the essence of the concept of brand value and valuation of brand as an important intellectual (intangible asset of the enterprise, as well as to identify the key elements that affect the financial value of the brand. Identifying these elements (ie. factors and drivers of brand value is very relevant for brand management aiming to ensure a greater contribution of a brand to the growth of the market value and improving competitiveness of an enterprise in future. The aim of this paper is to analyze the advantages and limitations of different methodologies for financial valuation of the brand. The structure of the paper consists of several parts. First, our attention focuses on the key differences between the brand value and brand equity. After that, follows an analysis of the general aspects of the methodology of measuring the financial value of the brand, and more detailed analysis of income, cost and market valuation approaches. The results of this paper are identified strengths and limitations of the analyzed methodologies for financial valuation of the brand, as well as guidelines for their practical application. The results of research, regarding the methods of financial valuation, are directed to facilitating adequate selection by marketing managers and executives of enterprises who should use them for effective everyday brand management, but also to make important strategic business decisions effectively in realizing certain business and financial transactions.

  12. Creating Stakeholder Value through Risk Mitigation Measures in the Context of Disaster Management

    Directory of Open Access Journals (Sweden)

    Minna Räikkönen

    2017-10-01

    Full Text Available The resilience of critical infrastructure (CI to extreme weather events (EWE is one of the most demanding challenges for all stakeholders in modern society. Although partial risk reduction is feasible through the introduction and implementation of various risk mitigation measures (RMM, decision-makers at all decision-making levels are pressured to find ways to cope with the impending extreme weather and to have a thorough understanding of the EWE impacts on CI. This paper discusses how the value of RMMs can be created and assessed in a stakeholder network. Qualitative research methods, namely literature review and AHP (Analytic Hierarchy Process, were applied as research methods. The paper examines how disaster management and value creation both converge and differ from each other. It also presents a case study on the value of various RMM and the impacts of extreme winter conditions on electricity distribution in Finland. Based on the case study, the most important value criterion was the benefits of the RMM in economic, social, and environmental terms. At a fundamental level, the value of RMM should be expressed not only in terms of money but also in regard to safety, security, societal acceptability, CI dependability, and other typically intangible criteria. Moreover, the results reveal that the interrelationship of value creation and disaster management offers new insights to both approaches.

  13. New measurements of W-values for protons and alpha particles

    International Nuclear Information System (INIS)

    Giesen, U.; Beck, J.

    2014-01-01

    The increasing importance of ion beams in cancer therapy and the lack of experimental data for W-values for protons and heavy ions in air require new measurements. A new experimental set-up was developed at PTB and consistent measurements of W-values in argon, nitrogen and air for protons and alpha particles with energies from 0.7 to 3.5 MeV u -1 at PTB, and for carbon ions between 3.6 and 7.0 MeV u -1 at GSI were carried out. This publication concentrates on the measurements with protons and alpha particles at PTB. The experimental methods and the determination of corrections for recombination effects, beam-induced background radiation and additional effects are presented. W-values in argon, nitrogen and air were measured for protons with energies of 1-3 MeV and for alpha particles with energies of 2.7-14 MeV. The energies of the primary particle beam were corrected for energy losses in the gold and Mylar foils, as well as for the kinematic energy loss due to scattering by 45 deg.. Beam-induced radiation backgrounds as well as recombination effects were determined and corrected for. The present results are summarised in Figure 2 for all three gases. The solid lines through the data points for each gas indicate an average W-value for that gas. The higher values for 2.7-MeV alpha particles agree with the trend in previous data towards lower energies. They are excluded from the averages. The relative standard uncertainties of the individual data points range from 1.3 to 3 %. The weighted averages over all energies are W(Ar) = 25.7 eV, W(N 2 ) = 35.6 eV and W(Air) = 34.2 eV. The averages serve as a first comparison and the lines on the plot are to guide the eye and are not meant to imply constant W-values for all energies and particles. The W-values for protons and alpha particles in argon and nitrogen have smaller uncertainties and are lower than the suggested values, but they are still in agreement within the uncertainties. For alpha particles with energies of 12

  14. Monitoring training status with HR measures: do all roads lead to Rome?

    Directory of Open Access Journals (Sweden)

    Martin eBuchheit

    2014-02-01

    Full Text Available Monitoring an athlete's physiological status in response to various types and volumes of (aerobic-oriented training can provide useful information for optimizing training programs. Measures of resting, exercise and recovery heart rate (HR are receiving increasing interest for monitoring fatigue, fitness and endurance performance responses, which has direct implications for adjusting training load 1 daily during specific training blocks and 2 throughout the competitive season. These measures are still not widely implemented to monitor athletes’ responses to training load, probably because of apparent contradictory findings in the literature. In this review I contend that most of the contradictory findings are related to methodological inconsistencies and/or misinterpretation of the data rather than to limitations of heart rate measures to accurately inform on training status. I also provide evidence that measures derived from 5-min (almost daily recordings of resting (indices capturing beat-to-beat changes in HR, reflecting parasympathetic activity and submaximal exercise (30- to 60-s average HR are likely the most useful monitoring tools. For appropriate interpretation at the individual level, changes in a given measure should be interpreted by taking into account the error of measurement and the smallest important change of the measure, as well as the training context (training phase, load and intensity distribution. The decision to use a given measure should be based upon the level of information that is required by the athlete, the marker’s sensitivity to changes in training status and the practical constrains required for the measurements. However, measures of HR cannot inform on all aspects of wellness, fatigue and performance, so their use in combination with daily training logs, psychometric questionnaires and non-invasive, cost-effective performance tests such as a countermovement jump may offer a complete solution to monitor

  15. Measuring and Managing Value Co-Creation Process: Overview of Existing Theoretical Models

    Directory of Open Access Journals (Sweden)

    Monika Skaržauskaitė

    2013-08-01

    Full Text Available Purpose — the article is to provide a holistic view on concept of value co-creation and existing models for measuring and managing it by conducting theoretical analysis of scientific literature sources targeting the integration of various approaches. Most important and relevant results of the literature study are presented with a focus on changed roles of organizations and consumers. This article aims at contributing theoretically to the research stream of measuring co-creation of value in order to gain knowledge for improvement of organizational performance and enabling new and innovative means of value creation. Design/methodology/approach. The nature of this research is exploratory – theoretical analysis and synthesis of scientific literature sources targeting the integration of various approaches was performed. This approach was chosen due to the absence of established theory on models of co-creation, possible uses in organizations and systematic overview of tools measuring/suggesting how to measure co-creation. Findings. While the principles of managing and measuring co-creation in regards of consumer motivation and involvement are widely researched, little attempt has been made to identify critical factors and create models dealing with organizational capabilities and managerial implications of value co-creation. Systematic analysis of literature revealed a gap not only in empirical research concerning organization’s role in co-creation process, but in theoretical and conceptual levels, too. Research limitations/implications. The limitations of this work as a literature review lies in its nature – the complete reliance on previously published research papers and the availability of these studies. For a deeper understanding of co-creation management and for developing models that can be used in real-life organizations, a broader theoretical, as well as empirical, research is necessary. Practical implications. Analysis of the

  16. Anorectal physiology measurements are of no value in clinical practice. True or false?

    Science.gov (United States)

    Carty, N. J.; Moran, B.; Johnson, C. D.

    1994-01-01

    This article examines whether there is any clinical value in anorectal physiology measurements. The function of the human rectum is poorly understood and the factors which affect function of the anal sphincters are complex. Several laboratories have reported results of anorectal physiology measurements, but there is extensive variation between normal values in different laboratories. It is argued that anorectal physiology measurements fail to meet the criteria of a useful clinical test: 1. It is not widely available to clinicians; 2. It is not possible to establish a reproducible normal range; 3. Abnormal measurements do not correlate with disease entities or explain symptoms; 4. The results are often unhelpful in diagnosis and management; 5. Clinical outcome after intervention does not correlate with alteration in the measurements obtained. On the other hand it can be argued that anorectal physiology measurements do provide information that assists in the management of conditions such as constipation, anismus, Hirschsprung's disease, faecal incontinence and tenesmus. Management based on biofeedback modification of physiological responses requires these techniques as part of the biofeedback system. There is evidence that this may be appropriate in anismus and solitary rectal ulcer syndrome. However, the assessment of these difficult conditions and the interpretation of the results are probably at present best confined to specialist units. PMID:8074392

  17. [QUALITY MEASURES IN MEDICINE-- A PLEA FOR NEW, VALUE BASED THINKING].

    Science.gov (United States)

    Fisher, Menachem; Wagner, Oded; Keinarl, Talia; Solt, Ido

    2015-09-01

    Quality is an important and basic conduct of complex systems in general and health systems in particular. Quality is a cornerstone of medicine, necessary in the eyes of the community of consumers, caregivers, and the systems that manage both. In Israel, the Ministry of Health has set the quality issue on the agenda of healthcare organizations in all existing frameworks. In this article we seek to offer an acceptable alternative perspective, in examining the quality of public health. We suggest highlighting the ethical aspect of medical care, while reducing the quantitative monitoring component of existing quality metrics. Relying solely on indices has negative effects that might cause damage. The proposed alternative focuses on the personal responsibility of health care providers, using. values and moral reasonin.

  18. The added value of measuring thumb and finger strength when comparing strength measurements in hypoplastic thumb patients.

    Science.gov (United States)

    Molenaar, H M Ties; Selles, Ruud W; de Kraker, Marjolein; Stam, Henk J; Hovius, Steven E R

    2013-10-01

    When interventions to the hand are aimed at improving function of specific fingers or the thumb, the RIHM (Rotterdam Intrinsic Hand Myometer) is a validated tool and offers more detailed information to assess strength of the involved joints besides grip and pinch measurements. In this study, strength was measured in 65 thumbs in 40 patients diagnosed with thumb hypoplasia. These 65 thumbs were classified according to Blauth. Longitudinal radial deficiencies were also classified. The strength measurements comprised of grip, tip, tripod and key pinch. Furthermore palmar abduction and opposition of the thumb as well as abduction of the index and little finger were measured with the RIHM. For all longitudinal radial deficiency patients, grip and pinch strength as well as palmar abduction and thumb opposition were significantly lower than reference values (P<0.001). However, strength in the index finger abduction and the little finger abduction was maintained or decreased to a lesser extent according to the degree of longitudinal radial deficiency. All strength values decreased with increasing Blauth-type. Blauth-type II hands (n=15) with flexor digitorum superficialis 4 opposition transfer including stabilization of the metacarpophalangeal joint showed a trend toward a higher opposition strength without reaching statistical significance (P=0.094),however compared to non-operated Blauth-type II hands (n=6) they showed a lower grip strength (P=0.019). The RIHM is comparable in accuracy to other strength dynamometers. Using the RIHM, we were able to illustrate strength patterns on finger-specific level, showing added value when evaluating outcome in patients with hand related problems. © 2013.

  19. Values of Deploying a Compact Polarimetric Radar to Monitor Extreme Precipitation in a Mountainous Area: Mineral County, Colorado

    Science.gov (United States)

    Cheong, B. L.; Kirstetter, P. E.; Yu, T. Y.; Busto, J.; Speeze, T.; Dennis, J.

    2015-12-01

    Precipitation in mountainous regions can trigger flash floods and landslides especially in areas affected by wildfire. Because of the small space-time scales required for observation, they remain poorly observed. A light-weighted X-band polarimetric radar can rapidly respond to the situation and provide continuous rainfall information with high resolution for flood forecast and emergency management. A preliminary assessment of added values to the operational practice in Mineral county, Colorado was performed in Fall 2014 and Summer 2015 with a transportable polarimetric radar deployed at the Lobo Overlook. This region is one of the numerous areas in the Rocky Mountains where the WSR-88D network does not provide sufficient weather coverage due to blockages, and the limitations have impeded forecasters and local emergency managers from making accurate predictions and issuing weather warnings. High resolution observations were collected to document the precipitation characteristics and demonstrate the added values of deploying a small weather radar in such context. The analysis of the detailed vertical structure of precipitation explain the decreased signal sampled by the operational radars. The specific microphysics analyzed though polarimetry suggest that the operational Z-R relationships may not be appropriate to monitor severe weather over this wildfire affected region. Collaboration with the local emergency managers and the National Weather Service shows the critical value of deploying mobile, polarimetric and unmanned radars in complex terrain. Several selected cases are provided in this paper for illustration.

  20. Relative value of clinical variables, bicycle ergometry, rest radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring at discharge to predict 1 year survival after myocardial infarction

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); R.W. Brower (Ronald); M.L. Simoons (Maarten); H.J. ten Katen (Harald); A. Beelen (Anita); T. Baardman (Taco); J. Lubsen (Jacob); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractThe relative value of predischarge clinical variables, bicycle ergometry, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring for predicting survival during the first year in 351 hospital survivors of acute myocardial infarction was assessed. Discriminant

  1. Computing interval-valued reliability measures: application of optimal control methods

    DEFF Research Database (Denmark)

    Kozin, Igor; Krymsky, Victor

    2017-01-01

    The paper describes an approach to deriving interval-valued reliability measures given partial statistical information on the occurrence of failures. We apply methods of optimal control theory, in particular, Pontryagin’s principle of maximum to solve the non-linear optimisation problem and derive...... the probabilistic interval-valued quantities of interest. It is proven that the optimisation problem can be translated into another problem statement that can be solved on the class of piecewise continuous probability density functions (pdfs). This class often consists of piecewise exponential pdfs which appear...... as soon as among the constraints there are bounds on a failure rate of a component under consideration. Finding the number of switching points of the piecewise continuous pdfs and their values becomes the focus of the approach described in the paper. Examples are provided....

  2. Characteristic Rain Events: A Methodology for Improving the Amenity Value of Stormwater Control Measures

    DEFF Research Database (Denmark)

    Smit Andersen, Jonas; Lerer, Sara Maria; Backhaus, Antje

    2017-01-01

    of achieving amenity value is to stage the rainwater and thus bring it to the attention of the public. We present here a methodology for creating a selection of rain events that can help bridge between engineering and landscape architecture when dealing with staging of rainwater. The methodology uses......Local management of rainwater using stormwater control measures (SCMs) is gaining increased attention as a sustainable alternative and supplement to traditional sewer systems. Besides offering added utility values, many SCMs also offer a great potential for added amenity values. One way...... quantitative and statistical methods to select Characteristic Rain Events (CREs) for a range of frequent return periods: weekly, bi-weekly, monthly, bi-monthly, and a single rarer event occurring only every 1–10 years. The methodology for selecting CREs is flexible and can be adjusted to any climatic settings...

  3. Characteristic Rain Events: A Methodology for Improving the Amenity Value of Stormwater Control Measures

    DEFF Research Database (Denmark)

    Smit Andersen, Jonas; Lerer, Sara Maria; Backhaus, Antje

    2017-01-01

    Local management of rainwater using stormwater control measures (SCMs) is gaining increased attention as a sustainable alternative and supplement to traditional sewer systems. Besides offering added utility values, many SCMs also offer a great potential for added amenity values. One way...... of achieving amenity value is to stage the rainwater and thus bring it to the attention of the public. We present here a methodology for creating a selection of rain events that can help bridge between engineering and landscape architecture when dealing with staging of rainwater. The methodology uses......; here we show its use for Danish conditions. We illustrate with a case study how CREs can be used in combination with a simple hydrological model to visualize where, how deep and for how long water is visible in a landscape designed to manage rainwater....

  4. Possible applications of instruments of measurement of the customer value in the operations of logistics companies

    Directory of Open Access Journals (Sweden)

    2011-12-01

    Full Text Available Background: The growing popularity in recent years of marketing concepts of putting clients in the centre of the interest of companies as well as easy access to data related to customers' behaviors led to the increase of the importance of such concepts as the profitability and the value of the customer. But the customer value in not an unequivocal concept. It can be defined and measured individually depending on the needs of a company, an industry character, objectives or a time horizon. Methods: The following, most often used, methods for measuring customer value were selected, described and analyzed from the point of view of their usefulness: different types of the portfolio method (e.g. two-steps and three-steps one, nine-field matrix, etc, multidimensional analysis of customers, analysis of the rentability of customers, model PCV, ABC method, RFM method and CLV indicator. Results: The advantages and disadvantages of each of analyzed methods were presented and evaluated. The possible use of each of the methods was presented and discussed. In the sector of logistics companies, the measurement of the customer value can be an effective tool in managing the customer relationships and in increasing their profitability. Since there is no only one universal way of measuring the customer value, which is appropriate for every selected industry branch, the choice of a particular method depends on many factors, such as a business profile or number of clients served by a company. Conclusions: The aim of the identification of key customers is to facilitate the optimal allocation of resources of the company. Not all customers are equally important for the company, and the company is not able and should not try to acquire and satisfy needs of each customer. It should be remembered, that the evaluation of the customer value in logistics companies should not be restricted to only one of discussed methods. The analysis presented in this paper indicates, that

  5. Monitoring and Fault Detection in Photovoltaic Systems Based On Inverter Measured String I-V Curves

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Kerekes, Tamas

    2015-01-01

    Most photovoltaic (PV) string inverters have the hardware capability to measure at least part of the current-voltage (I-V) characteristic curve of the PV strings connected at the input. However, this intrinsic capability of the inverters is not used, since I-V curve measurement and monitoring...... functions are not implemented in the inverter control software. In this paper, we aim to show how such a functionality can be useful for PV system monitoring purposes, to detect the presence and cause of power-loss in the PV strings, be it due to shading, degradation of the PV modules or balance......-of-system components through increased series resistance losses, or shunting of the PV modules. To achieve this, we propose and experimentally demonstrate three complementary PV system monitoring methods that make use of the I-V curve measurement capability of a commercial string inverter. The first method is suitable...

  6. Monitoring network for doserate-measurements with wireless datatransmitting in Baden-Wuerttemberg

    International Nuclear Information System (INIS)

    Aures, R.; Wenzel, H.

    2003-01-01

    In the environment of the nuclear power plants Philippsburg, Obrigheim and Neckarwestheim in Baden-Wuerttemberg there is a monitoring network with 90 stations. They are measuring the gamma-dose rate. In the meantime these monitoring stations are nearly 20 years old and now it is time to substitute old technology by a new one. The aim is a mix of monitoring stations with phone wire- and wireless data transmission (Skylink). Thinkable is a part of 50 % of Skylink-tubes in the monitoring network and some for mobile performance. The main aspect of the planned substitution is a second independent way of data transmission. Normally there are no problems for data transmission. But in case of emergency the data transmissions which depends from phone wires could be delayed if there are too much dates. So the second way, the way of wireless data transmissions becomes important. The Landesanstalt fuer Umweltschutz in Karlsruhe has bought a complete system from the company Genitron in Frankfurt/Main. The system (Skylink) consists of the receiver and the does rate-monitoring stations. Such a system was tested successfully in a region with many mountains and deep valleys. Since July 2000 the Skylink-system is performed in the ''Nuclear power monitoring system'' (KFUe) in Baden-Wuerttemberg. The receiver is on the Koenigstuhl (630 m) near Heidelberg. This is a very good position to receive the wireless transmitted dates from every monitoring station (Skylink Gammatracer) of the monitoring network. Now there are 27 Skylink Gammatracer spread in the monitoring network. At time they are placed near the dose rate tubes of the old monitoring stations for comparing the dose rates and they are working with best results. (orig.)

  7. Impact of energy efficiency measures on the economic value of buildings

    International Nuclear Information System (INIS)

    Popescu, Daniela; Bienert, Sven; Schuetzenhofer, Christian; Boazu, Rodica

    2012-01-01

    Highlights: → Market driven reasons can strengthen implementation of energy policies in buildings. → Methods that quantify the added value due to energy performance are developed. → Recommendations on how they can be incorporated in the financial analysis are presented. → Case studies on some existing condominiums from Romania are analyzed. → The market sensitivity to energy efficiency measures is also in the focus. -- Abstract: A main objective of energy policies is to make all levels of the society, from governments to citizen, interested in increasing the energy efficiency of buildings. One of the most important barriers in implementation of energy policies is that the cost of potential energy savings, typically considered being the only financial benefit, does not sufficiently motivate investments. The target is therefore to identify further possible drivers pushing positive reaction according to energy saving action. The paper discusses whether a market-based instrument, capturing the increase of the economic value of energy efficient buildings, can be also used. Methods that quantify the added value due to energy performance, including recommendations on how they can be incorporated in the financial analysis of investments in weatherization, are developed. By applying the proposed methods, the payback period of investments in energy efficiency measures depends on two factors: potential energy savings and the added value to the property. Case studies on some existing condominiums from Romania are analyzed and provide evidence to the research question. The market sensitivity to energy efficiency measures, the possibility of an intangible added value as well as the impact to financial investment decisions is subsequently in the focus.

  8. Behavioral and Locomotor Measurements Using an Open Field Activity Monitoring System for Skeletal Muscle Diseases

    OpenAIRE

    Tatem, Kathleen S.; Quinn, James L.; Phadke, Aditi; Yu, Qing; Gordish-Dressman, Heather; Nagaraju, Kanneboyina

    2014-01-01

    The open field activity monitoring system comprehensively assesses locomotor and behavioral activity levels of mice. It is a useful tool for assessing locomotive impairment in animal models of neuromuscular disease and efficacy of therapeutic drugs that may improve locomotion and/or muscle function. The open field activity measurement provides a different measure than muscle strength, which is commonly assessed by grip strength measurements. It can also show how drugs may affect other body sy...

  9. Monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors

    International Nuclear Information System (INIS)

    Stanc, S.; Repa, M.

    2001-01-01

    Description of a monitoring system for accuracy and reliability characteristics of standard temperature measurements in WWER-440 reactors and benefits obtained from its use are shown in the presentation. As standard reactor temperature measurement, coolant temperature measurement at fuel assembly outlets and in loops, entered into the In-Reactor Control System , are considered. Such systems have been implemented at two V-230 reactors and are under implementation at other four V-213 reactors. (Authors)

  10. Analysis of the Functional Independence Measure Value of Cervical Spine Injury Patients with Conservative Management

    Directory of Open Access Journals (Sweden)

    M. Zafrullah Arifin

    2012-06-01

    Full Text Available Analysis of the Functional Independence Measure Value of Cervical Spine Injury Patients with Conservative Management. Cervical spine injury is one of the most common spinal cord injuries in trauma patients. From 100,000 spinal cord injury cases reported in the United States of America (2008, sixty seven percent involve cervical spine injury. American Spinal Cord Injury Association (ASIA impairment score is used as an initial assessment but not enough attention prognostic outcome of these patients was paid to. The objective of this study is to analyze the value of functional independence measure (FIM cervical spine injury patients with conservative management and its correlation with age, sex, type of trauma, onset of trauma, cervical abnormalities, type of cervical spine lesion and ASIA impairment score. A prospective cohort study was performed to all patients with cervical spine injury treated inNeurosurgery Department of Dr. Hasan Sadikin Hospital Bandung that fullfiled the inclusion criteria. The subjects were classified based on age, sex, single/multiple trauma, acute /chronic, cervical abnormalities, complete/incomplete lesion and ASIA impairment score. The FIM examination was performed in Outpatient clinic of Neurosurgery. T-test and chi-square test was done to analyze the data. There were 17 cervical spine injury patients treated in Neurosurgery Department of Dr. Hasan Sadikin Hospital during April 2009–April 2010. The average FIM value of cervical spine injury in those patients is 4+ 1.63 by cohort prospective study. There were no correlation between FIM value with age, sex, type of trauma, onset of trauma and cervical abnormalities. Significant correlations were found between FIM value with type of cervical spine lesion and ASIA impairment score in cervical spine patients. Type of cervical spine lesion and ASIA impairment score have significant correlation with FIM value of patients in 6 months after cervical injury.

  11. Added value measures in education show genetic as well as environmental influence.

    Science.gov (United States)

    Haworth, Claire M A; Asbury, Kathryn; Dale, Philip S; Plomin, Robert

    2011-02-02

    Does achievement independent of ability or previous attainment provide a purer measure of the added value of school? In a study of 4000 pairs of 12-year-old twins in the UK, we measured achievement with year-long teacher assessments as well as tests. Raw achievement shows moderate heritability (about 50%) and modest shared environmental influences (25%). Unexpectedly, we show that for indices of the added value of school, genetic influences remain moderate (around 50%), and the shared (school) environment is less important (about 12%). The pervasiveness of genetic influence in how and how much children learn is compatible with an active view of learning in which children create their own educational experiences in part on the basis of their genetic propensities.

  12. Can the reinforcing value of food be measured in bulimia nervosa?

    Science.gov (United States)

    Schebendach, Janet; Broft, Allegra; Foltin, Richard W; Walsh, B Timothy

    2013-03-01

    Binge eating is a core clinical feature of bulimia nervosa (BN). Enhanced reinforcing value of food may play a role in this behavioral disturbance, but a systematic behavioral assessment of objective measures of the rewarding value of binge eating is lacking. The purpose of this study was to quantify the reinforcing value of food in BN patients as compared with normal controls. A progressive ratio (PR) computerized work task was completed under binge and non-binge instruction. The task consisted of 12 trials. The first trial required 50 keyboard taps to earn one portion of yogurt shake, and subsequent trials required progressive work increments of 200 taps for each additional portion. Completion of all 12 trials required 13,800 taps to earn 2100ml of shake. The breakpoint, defined as the largest ratio completed before a participant stopped working, was the measure of reinforcing efficacy. Ten patients and 10 controls completed the experiment. Under binge instruction, patients completed more trials and taps, and had a higher breakpoint than controls. The non-binge instruction yielded opposite findings; compared to controls, patients completed fewer trials and taps, and had a lower breakpoint. These results support the feasibility and potential utility of a PR task to quantify the reinforcing value of food in patients with BN. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. The Role of Patient-Reported Outcome Measures in Value-Based Payment Reform.

    Science.gov (United States)

    Squitieri, Lee; Bozic, Kevin J; Pusic, Andrea L

    2017-06-01

    The U.S. health care system is currently experiencing profound change. Pressure to improve the quality of patient care and control costs have caused a rapid shift from traditional volume-driven fee-for-service reimbursement to value-based payment models. Under the 2015 Medicare Access and Children's Health Insurance Program Reauthorization Act, providers will be evaluated on the basis of quality and cost efficiency and ultimately receive adjusted reimbursement as per their performance. Although current performance metrics do not incorporate patient-reported outcome measures (PROMs), many wonder whether and how PROMs will eventually fit into value-based payment reform. On November 17, 2016, the second annual Patient-Reported Outcomes in Healthcare Conference brought together international stakeholders across all health care disciplines to discuss the potential role of PROs in value-based health care reform. The purpose of this article was to summarize the findings from this conference in the context of recent literature and guidelines to inform implementation of PROs in value-based payment models. Recommendations for evaluating key perspectives and measurement goals are made to facilitate appropriate use of PROMs to best benefit and amplify the voice of our patients. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  14. Microwave measurements of the absolute values of absorption by water vapour in the atmosphere.

    Science.gov (United States)

    Hogg, D C; Guiraud, F O

    1979-05-31

    MEASUREMENT of the absolute value of absorption by water vapour at microwave frequencies is difficult because the effect is so small. Far in the wings of the absorption lines, in the so-called 'windows' of the spectrum, it is especially difficult to achieve high accuracy in the free atmosphere. But it is in these windows that the behaviour of the absorption is important from both applied and scientific points of view. Satellite communications, remote sensing of the atmosphere, and radioastronomy, are all influenced by this behaviour. Measurements on an Earth-space path are reported here; the results indicate a nonlinear relationship between absorption and water-vapour content.

  15. Comparison between theoretical values foreseen and measured during the commissioning of second cycle of Angra-1

    International Nuclear Information System (INIS)

    Angelkorte, G.; Dias, A.M.; Sakai, M.

    1988-01-01

    The purpose of this paper is to present the most important results of the comparison of the data measured during the start-up tests for the second cycle of Angra 1 with the calculated values for this cycle. This short comparison considered the following quantities: Critical boron concentration, Control rod worths, Isothermal temperature coefficient, Reaction rates of the incore detector system. The calculated results showed good agreement with the measured ones remaining within the acceptation criteria limits, confirming the fuel management calculations for the second cycle, namely that for the reload scheme obtained, the core is capable of operating at nominal power safety and without restrictions. (author) [pt

  16. Logarithmic Similarity Measure between Interval-Valued Fuzzy Sets and Its Fault Diagnosis Method

    Directory of Open Access Journals (Sweden)

    Zhikang Lu

    2018-02-01

    Full Text Available Fault diagnosis is an important task for the normal operation and maintenance of equipment. In many real situations, the diagnosis data cannot provide deterministic values and are usually imprecise or uncertain. Thus, interval-valued fuzzy sets (IVFSs are very suitable for expressing imprecise or uncertain fault information in real problems. However, existing literature scarcely deals with fault diagnosis problems, such as gasoline engines and steam turbines with IVFSs. However, the similarity measure is one of the important tools in fault diagnoses. Therefore, this paper proposes a new similarity measure of IVFSs based on logarithmic function and its fault diagnosis method for the first time. By the logarithmic similarity measure between the fault knowledge and some diagnosis-testing samples with interval-valued fuzzy information and its relation indices, we can determine the fault type and ranking order of faults corresponding to the relation indices. Then, the misfire fault diagnosis of the gasoline engine and the vibrational fault diagnosis of a turbine are presented to demonstrate the simplicity and effectiveness of the proposed diagnosis method. The fault diagnosis results of gasoline engine and steam turbine show that the proposed diagnosis method not only gives the main fault types of the gasoline engine and steam turbine but also provides useful information for multi-fault analyses and predicting future fault trends. Hence, the logarithmic similarity measure and its fault diagnosis method are main contributions in this study and they provide a useful new way for the fault diagnosis with interval-valued fuzzy information.

  17. Differential calculus for Dirichlet forms: The measure-valued gradient preserved by image

    OpenAIRE

    Bouleau, Nicolas

    2005-01-01

    In order to develop a differential calculus for error propagation we study local Dirichlet forms on probability spaces with square field operator $\\Gamma$ -- i.e. error structures -- and we are looking for an object related to $\\Gamma$ which is linear and with a good behaviour by images. For this we introduce a new notion called the measure valued gradient which is a randomized square root of $\\Gamma$. The exposition begins with inspecting some natural notions candidate to solve the problem b...

  18. Uniqueness of Gibbs Measure for Models with Uncountable Set of Spin Values on a Cayley Tree

    International Nuclear Information System (INIS)

    Eshkabilov, Yu. Kh.; Haydarov, F. H.; Rozikov, U. A.

    2013-01-01

    We consider models with nearest-neighbor interactions and with the set [0, 1] of spin values, on a Cayley tree of order K ≥ 1. It is known that the ‘splitting Gibbs measures’ of the model can be described by solutions of a nonlinear integral equation. For arbitrary k ≥ 2 we find a sufficient condition under which the integral equation has unique solution, hence under the condition the corresponding model has unique splitting Gibbs measure.

  19. International target values 2010 for achievable measurement uncertainties in nuclear material accountancy

    International Nuclear Information System (INIS)

    Dias, Fabio C.; Almeida, Silvio G. de; Renha Junior, Geraldo

    2011-01-01

    The International Target Values (ITVs) are reasonable uncertainty estimates that can be used in judging the reliability of measurement techniques applied to industrial nuclear and fissile materials subject to accountancy and/or safeguards verification. In the absence of relevant experimental estimates, ITVs can also be used to select measurement techniques and calculate sample population during the planning phase of verification activities. It is important to note that ITVs represent estimates of the 'state-of-the-practice', which should be achievable under routine measurement conditions affecting both facility operators and safeguards inspectors, not only in the field, but also in laboratory. Tabulated values cover measurement methods used for the determination of volume or mass of the nuclear material, for its elemental and isotopic assays, and for its sampling. The 2010 edition represents the sixth revision of the International Target Values (ITVs), issued by the International Atomic Energy Agency (IAEA) as a Safeguards Technical Report (STR-368). The first version was released as 'Target Values' in 1979 by the Working Group on Techniques and Standards for Destructive Analysis (WGDA) of the European Safeguards Research and Development Association (ESARDA) and focused on destructive analytical methods. In the latest 2010 revision, international standards in estimating and expressing uncertainties have been considered while maintaining a format that allows comparison with the previous editions of the ITVs. Those standards have been usually applied in QC/QA programmes, as well as qualification of methods, techniques and instruments. Representatives of the Brazilian Nuclear Energy Commission (CNEN) and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC) participated in previous Consultants Group Meetings since the one convened to establish the first list of ITVs released in 1993 and in subsequent revisions, including the latest one

  20. Method for incorporation monitoring - Studies on measurement and interpretation of radionuclide excretion, particularly thorium decay products, via exhaled breath

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    The development and application of a measuring method is described for thorium incorporation monitoring by way of measuring Rn-220 (thoron) in exhaled breath. The method is intended for application to monitoring the incorporation of thorium by occupationally exposed persons in compliance with the regulatory guide on health physics monitoring for determination of whole-body dose. (orig./CB) [de