WorldWideScience

Sample records for moisture meters measure

  1. Optimization on Measurement Method for Neutron Moisture Meter

    International Nuclear Information System (INIS)

    Gong Yalin; Wu Zhiqiang; Li Yanfeng; Wang Wei; Song Qingfeng; Liu Hui; Wei Xiaoyun; Zhao Zhonghua

    2010-01-01

    When the water in the measured material is nonuniformity, the measured results of the neutron moisture meter in the field may have errors, so the measured errors of the moisture meter associated with the water nonuniformity in material were simulated by Monte Carlo method. A new measurement method of moisture meter named 'transmission plus scatter' was put forward. The experiment results show that the new measurement method can reduce the error even if the water in the material is nonuniformity. (authors)

  2. Integrating an embedded system in a microwave moisture meter

    Science.gov (United States)

    The conversion of a PC- or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter measures the attenuation and phase shift of low power microwaves traversing the sample, from which the dielectric properties are calculated. T...

  3. Integrating an Embedded System within a Microwave Moisture Meter

    Science.gov (United States)

    In this paper, the conversion of a PC or laptop-controlled microwave moisture meter to a stand-alone meter hosting its own embedded system is discussed. The moisture meter uses low-power microwaves to measure the attenuation and phase shift of the sample, from which the dielectric properties are cal...

  4. BH5047 type depth sand moisture-meter of high sensitivity

    International Nuclear Information System (INIS)

    Ji Changsong; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    2000-01-01

    A new depth neutron moisture meter BH5047 has been developed. BH5047 neutron moisture meter is characterised by it is high sensitivity and used for sand water content measurement at concrete mixer. Calibration function is obtained by the Method of Least Squares. Linear correlation efficiency is as good as 0.9977

  5. Characteristics and calibration of the transmission-type fast neutron moisture meter

    International Nuclear Information System (INIS)

    Banzai, K.

    1984-01-01

    With the Transmission-type Fast Neutron Moisture Meter, we did some experiments for calibration and the effective range of fast neutron scattering, and observed soil moisture process before and after making artificial rainfall at a lysimeter filled by decomposed granite. A fast neutron source of this meter is 252 Cf and capacity of 100 μ Ci. The neutron detector is NE-213 liquid scintilator which recovers a little flux of neutron source. For the customary thermal neutron meter, the effective range of neutron scattering is variable by soil moisture values surrounding the observation point, but this fast neutron, insert and transmission-type meter shows soil moisture in small capacity between a source and a detector. Experimental Results; 1) The calibration curve, calculated statistically from the relation of soil moisture and the count ratio in a 200 l drum packed with beads, gravel, sand and Kanto loam, became only one line. The correlation coefficient of this curve was 0.996 and the standard error was 1.94% with volumetric water content. 2) Count ratio started to decrease as observation point approached soil surface from the boundary of 6 cm depth in soil. Volumetric water content increased more than fact with the previous calibration curve. 3) We limited the detectable range to fast neutron, but a little scattering was seen surrounding the soil of a observation point. The effective range of horizontal scattering was a width of 20 cm with the center line connected between a source and a detector, with a circle of 5 cm diameter surrounding the source, and a circle of 10-15 cm diameter surrounding the detector. 4) Soil moisture before and after artificial rainfall was observed with this meter and by the measurement of a 100 cm 3 oven dried sampling vessel. Volumetric water content by the latter measurement, was more variable because sampling points were at a distance from the center of observation site and sampling technique was bad. Otherwise soil moisture values

  6. 7 CFR 801.6 - Tolerances for moisture meters.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerances for moisture meters. 801.6 Section 801.6 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD... FOR GRAIN INSPECTION EQUIPMENT § 801.6 Tolerances for moisture meters. (a) The maintenance tolerances...

  7. Digital radioisotope moisture-density meter

    International Nuclear Information System (INIS)

    Bychvarov, N.; Vankov, I.; Dimitrov, L.

    1982-01-01

    The primary information from the detectors of a combined radioisotope moisture-density meter is obtained as pulses, their counting rate being functionally dependent on the humidity per unit volume and the wet density. However, most practical cases demand information on the moisture per unit weight and the mass density of the dry skeleton. The paper describes how the proposed electronic circuit processes the input primary information to obtain the moisture in weight % and the mass density of the dry skeleton in g/cm 3 . (authors)

  8. Water table and the neutron moisture meter

    Energy Technology Data Exchange (ETDEWEB)

    Visvalingam, M [Hull Univ. (UK). Geography Dept.

    1975-12-01

    Measurements with a neutron moisture meter at Westlands, near Hull, showed count rates at capillary saturation to be within the error limits of count rates at full saturation. However, the saturation profiles in themselves were interesting as they indicated not only the zonation of the soil but also differences in drainable porosity when compared to count-rate profiles at the end of November.

  9. Determination of moisture content in hard coals using microwave meter

    International Nuclear Information System (INIS)

    Chrusciel, E.; Kopec, M.; Turek, B.

    1989-01-01

    The results of hard-coal moisture-content measurements, performed with the aid of the ZAM-WILMER microwave meter are presented. Over 80 ground coal samples, weighing 1.5 kg (approx.) each, were examined. The moisture content values ranged from 0 to 15 wt%, with the mean standard error being equal to 0.8 wt%. 5 refs., 2 figs., 1 tab. (author)

  10. Quality Assurance of Rice and Paddy Moisture Measurements in Thailand

    Science.gov (United States)

    Sinhaneti, T.; Keawprasert, T.; Puuntharo, P.; Triarun, W.

    2017-10-01

    A bilateral comparison in moisture measurement between the National Institute of Metrology Thailand (NIMT) and the Central Bureau of Weights and Measures (CBWM) was organized for quality assuring of rice and paddy moisture measurement in Thailand. The bilateral comparison was conducted by using the same batch of sample and moisture meter as transfer device. It consisted of two parts: moisture measurement in rice and in paddy. A rice moisture meter belonging to CBWM and rice standards prepared at the nominal moisture content of 10 %, 12 %, 14 % and 16 % at NIMT, were used for rice moisture comparison, while a paddy moisture meter belonging to NIMT and paddy standards prepared at the nominal moisture content of 12 %, 14 %, 16 % and 18 % at CBWM, were used for paddy moisture comparison. Both laboratories measured the moisture content of a sample by using the standard method in ISO 712 and used that sample to calibrate a moisture meter by means of the method based on ISO 7700-1. Since the moisture content of the sample can change during the comparison, correction values in moisture content between the standard value and the reading value from the moisture meter are used as calibration results for the comparison evaluation. For the rice moisture comparison, differences in the correction value measured by the two laboratories vary from 0.18 % to 0.46 %, with their combined comparison uncertainty of 0.37 % (k= 2). The main contribution to the difference comes from the standard values from both laboratories differing from 0.27 % to 0.53 %, as the rice standard was found to drift in moisture content less than 0.05 %. Similarly to the rice moisture comparison, differences in the correction value for the paddy moisture measurement range from 0.08 % to 0.56 % with the combined comparison uncertainty of 0.38 % (k = 2), whereas the stability in moisture content of the paddy sample at NIMT was found to be within 0.12 %.

  11. Moisture meter calibrations for untreated and ACQ-treated southern yellow pine lumber and plywood

    Science.gov (United States)

    C.R. Boardman; Samuel V. Glass; Charles G. Carll

    2011-01-01

    This study investigates the effects of alkaline copper quaternary (ACQ) preservative treatment and of plywood glue lines on resistance-based moisture content (MC) measurements. Moisture meter readings using stainless steel screws as electrodes were acquired over a range of moisture conditions in Southern Yellow Pine (SYP) lumber and plywood. Calibration equations are...

  12. Moisture meter calibration for untreated and ACQ-treated southern yellow pine plywood

    Science.gov (United States)

    Samuel V. Glass; Charles G. Carll

    2009-01-01

    Conductance moisture meter readings using stainless steel screws as electrodes were compared with gravimetric moisture content for 1) southern yellow pine (SYP) dimensioned lumber, 2) untreated (underlayment grade) SYP plywood, and 3) SYP plywood treated with alkaline copper quaternary. Meter readings were taken with the meter set to the manufacturer-provided species...

  13. Study of Material Moisture Measurement Method and Instrument by the Combination of Fast Neutron Absorption and γ Absorption

    International Nuclear Information System (INIS)

    Hou Chaoqin; Gong Yalin; Zhang Wei; Shang Qingmin; Li Yanfeng; Gou Qiangyuan; Yin Deyou

    2010-01-01

    To solve the problem of on-line sinter moisture measurement in the iron making plant, we developed material moisture measurement method and instrument by the combination of fast neutron absorption and y-absorption. It overcomes the present existed problems of other moisture meters for the sinter. Compare with microwave moisture meter, the measurement dose not affected by conductance and magnetism of material; to infrared moisture meter, the measurement result dose not influenced by colour and light-reflect performance of material surface, dose not influenced by changes of material kind; to slow neutron scatter moisture meter, the measurement dose not affected by density of material and thickness of hopper wall; to the moisture measurement meter which combined by slow neutron penetrate through and y-absorption, there are definite math model and good linear relation between the measurement values, and the measurement dose not affected by material thickness, changes of material form and component. (authors)

  14. A Portable Solid-State Moisture Meter For Agricultural And Food Products

    Science.gov (United States)

    Bull, C. R.; Stafford, J. V.; Weaving, G. S.

    1988-10-01

    This paper reports on the development of a small, robust, battery operated near infra-red (NIR) reflectance device, designed for rapid on-farm measurement of the moisture content of forage crops without prior sample preparation. It has potential application to other agricultural or food materials. The instrument is based on two light emitting diodes (LEDs), a germanium detector and a control CMOS single chip microcomputer. The meter has been calibrated to give a direct read out of moisture content for 4 common grass varieties at 3 stages of development. The accuracy of a single point measurement on a grass sample is approximately +/- 6% over a range of 40-80% (wet basis). However, the potential accuracy on a homogeous sample may be as goon as 0.15%.

  15. Design and Fabrication of a Soil Moisture Meter Using Thermal Conductivity Properties of Soil

    Directory of Open Access Journals (Sweden)

    Subir DAS

    2011-09-01

    Full Text Available Study of soil for agricultural purposes is one of the main focuses of research since the beginning of civilization as food related requirements is closely linked with the soil. The study of soil has generated an interest among the researchers for very similar other reasons including understanding of soil water dynamics, evolution of agricultural water stress and validation of soil moisture modeling. In this present work design of a soil moisture measurement meter using thermal conductivity properties of soil has been proposed and experimental results are reported.

  16. Measurement of Moisture in Wood for Application in the Restoration of Old Buildings.

    Science.gov (United States)

    Moron, Carlos; Garcia-Fuentevilla, Luisa; Garcia, Alfonso; Moron, Alberto

    2016-05-14

    There are many historic buildings whose construction is based on timber frame walls. Most buildings built during the nineteenth and early twentieth centuries were based on timber frame walls with vertical support elements. These timber frame elements are affected by their moisture content and by the passage of time. If the interaction of the timber frame walls with hygrothermal fluctuations were known, the maintenance of these buildings could be improved significantly. To determine the moisture content of wood there are two types of meters on the market: on the one hand, capacitance meters which consist of two side ends and where the moisture content is measured locally between two peaks. On the other hand, there are meters based on the variation of electromagnetic transmittance of timber, which depends on the moisture of timber. The second ones are very expensive and difficult to handle. This work presents a new non-intrusive capacitive sensor that measures the global moisture content in a section of the timber frame walls and therefore its accuracy is similar to the accuracy that can be obtained with electromagnetic transmittance meters. Additionally, as it is a capacitive sensor, it is low cost and easy to operate.

  17. Measurement of Moisture in Wood for Application in the Restoration of Old Buildings

    Science.gov (United States)

    Moron, Carlos; Garcia-Fuentevilla, Luisa; Garcia, Alfonso; Moron, Alberto

    2016-01-01

    There are many historic buildings whose construction is based on timber frame walls. Most buildings built during the nineteenth and early twentieth centuries were based on timber frame walls with vertical support elements. These timber frame elements are affected by their moisture content and by the passage of time. If the interaction of the timber frame walls with hygrothermal fluctuations were known, the maintenance of these buildings could be improved significantly. To determine the moisture content of wood there are two types of meters on the market: on the one hand, capacitance meters which consist of two side ends and where the moisture content is measured locally between two peaks. On the other hand, there are meters based on the variation of electromagnetic transmittance of timber, which depends on the moisture of timber. The second ones are very expensive and difficult to handle. This work presents a new non-intrusive capacitive sensor that measures the global moisture content in a section of the timber frame walls and therefore its accuracy is similar to the accuracy that can be obtained with electromagnetic transmittance meters. Additionally, as it is a capacitive sensor, it is low cost and easy to operate. PMID:27187410

  18. The influence of natural and artificial precipitation on the moisture status of a black soil from the Marchfeld area, as determined by the neutron moisture meter

    International Nuclear Information System (INIS)

    Haunold, F.; Roetzer, H.; Storchschnabel, G.; Blochberger, K.

    1980-01-01

    Changes in the moisture status of a Chernozem in the Marchfeld were measured throughout a vegetation period using a neutron moisture meter from Berthold. Increasing the strength of the irradiation source from 30 to 100 mCi and changing the analog to digital recording, greatly improved the precision of measurement. The installation of the measuring tubes was possible only in soils free of stones. Measurements were made down to 140 cm depth. The field was planted with cabbage. One part of the field received normal rain only, one part received 40 mm of artificial precipitation when the moisture content of the soil in 40 cm depth dropped below 50 % of the water holding capacity. The third part received 3 times that amount of water. The changes in water status of the soil as a consequence of natural and artificial rain were very well recorded by the instrument. Therefore this method is very suitable for the measurement and control of the moisture status of the soil, in order to make proper decisions for the exact time of artificial irrigation. (author)

  19. Calibrating the neutron moisture meter: Precision and economy

    International Nuclear Information System (INIS)

    Akhter, J.; Waheed, R.A.; Hignett, C.T.; Greacen, E.L.

    2000-01-01

    Established laboratory and field calibration procedures for the neutron moisture meter are demonstrated on a uniform soil and alternative, low cost procedures on a duplex, less uniform soil. The effect of field variability on the calibration methodology is discussed with the aim of optimising calibration reliability at minimal cost. The difference between calibration for a soil material, or for a field (a range of soil materials) is considered. In particular, calibration for the estimation of water content change is shown to be a different problem from calibration for the estimation of water content in a variable field. Techniques aimed at detecting field variability problems during calibration are suggested, and methods for optimising the results for the intended use of the instrument are outlined. Pairing of calibration tubes, alternative methods of analysis of calibration data, and use of other information from the field to measure its variability, can improve the precision of calibration procedures to the point where minimal calibration effort, with careful analysis, can provide reliable results. (author)

  20. Microwave moisture meter for in-shell almonds.

    Science.gov (United States)

    Determining almond kernel moisture content while still in the shell is important for both almond growers and processors. A dielectric method was developed for almond kernel moisture determination from dielectric measurements on in-shell almonds at a single microwave frequency. A sample holder was fi...

  1. Digital neutron moisture meter for moisture determination in the cokes and building materials

    International Nuclear Information System (INIS)

    Chibovski, R.; Igel'ski, A.; Kiyanya, K.; Kiyanya, S.; Mnikh, Eh.; Sledzevski, R.; Verba, V.

    1979-01-01

    Description is given of the digital neutron moisture gage for measuring water content in coke or in dry building materials. The device can work independently with indication of the results to personnel carrying out control operation and adjustment of the process or as a part of an automated control system with supplying the results of measurements in a form of analogous signals or electric pulses in the preselected code. The moisture gage described consists of two units: measuring probes with containers and the desk with power supply and the system for digital processing of a radiometric signal. The measuring probe consists of the asotopic fast neutrons source; helium proportional counter of slow neutrons and a pulse amplifier. The probe is mounted in the bunker with the material measured and is located inside the protective tube made of the weare-resistant material. To obtain high accuracy of measurements and to obtain the measuring instrument's reading immediately in the units of moisture measurement, the digizal converter circuit for radiometric signals processing is used. The The digital converter circuit cited, can be applied to any calibration dependence of linear type with initial value. The block diagram of the device is given. The device described permits to measure the moisture content in the metallurgy coks and in the building materials in one minute and with the error not more than 0.5% [ru

  2. Components of variance involved in estimating soil water content and water content change using a neutron moisture meter

    International Nuclear Information System (INIS)

    Sinclair, D.F.; Williams, J.

    1979-01-01

    There have been significant developments in the design and use of neutron moisture meters since Hewlett et al.(1964) investigated the sources of variance when using this instrument to estimate soil moisture. There appears to be little in the literature, however, which updates these findings. This paper aims to isolate the components of variance when moisture content and moisture change are estimated using the neutron scattering method with current technology and methods

  3. Relationship between xerostomia and psychotropic drugs in patients with schizophrenia: evaluation using an oral moisture meter.

    Science.gov (United States)

    Okamoto, A; Miyachi, H; Tanaka, K; Chikazu, D; Miyaoka, H

    2016-12-01

    Patients with schizophrenia are most commonly treated with antipsychotic medications, often with the addition of anxiolytics. This study used an oral moisture meter to evaluate xerostomia in patients with schizophrenia taking typical and atypical antipsychotics, anxiolytics and non-psychotropic medications. Patients diagnosed with schizophrenia according to ICD-10 criteria in the Department of Psychiatry, Kitasato University East, and affiliated hospitals were studied. All patients were on psychotropic medications. Patients with diseases associated with xerostomia, such as Sjögren's syndrome I, were excluded. A total of 127 patients were enrolled. Mean oral moisture was 27·81 ± 2·27% (normal, ≥30·0%). A significant association was observed between objective oral moisture and the subjective sense of dry mouth. Multivariate analysis revealed a negative correlation between the number of antipsychotics and, especially, anxiolytics, and the degree of oral moisture. Drug dosages themselves were not significantly correlated with dry mouth. These findings suggest that objective oral moisture measurements show decreased moisture in patients on these medications and that the degree of moisture shows a greater negative correlation with the number, as opposed to the dosages, of psychotropic drugs administered. When patients with schizophrenia visit a dental clinic, it is important for the dentist to accurately assess the degree of oral moisture and to determine the medications being taken. Based on these findings of the association of polypharmacy with xerostomia, dentists are encouraged to inform the psychiatrist of the need to actively manage patients' xerostomia. © 2016 John Wiley & Sons Ltd.

  4. Development and evaluation of a low cost probe-type instrument to measure the equilibrium moisture content of grain

    Science.gov (United States)

    Storage bags are common in Africa, Asia and many other less developed countries therefore a grain probing method is well-suited for moisture content (MC) measurement. A low cost meter was developed as part of a USAID project to reduce the post-harvest loss (PHL). The meter measures the MC of maize a...

  5. The Neutron-Moisture Meter in Studies of the Effect of Fallow on Water Conservation in Arid Regions

    Energy Technology Data Exchange (ETDEWEB)

    Oezbek, Nurinnisa; Aksoy, Tevfik; Celebi, Gurkan [Radiophysiology and Soil Fertility Department, Faculty of Agriculture, University of Ankara, Ankara (Turkey)

    1967-11-15

    For a long time it has been a common practice for the Central Anatolian farmers to leave half the land fallow the whole year in order to increase the amount of water conserved. The main object of these studies was to ascertain whether fallow has an effect on moisture conservation in soils of this region and if so what was its degree of efficiency on a yearly basis. In view of the intensity and distribution of rainfall Ankara, Konya and Eski$ehir were selected for moisture-measurement areas. Altogether 60 holes were dug and 60 access tubes were used for moisture measurements by a neutron- moisture meter, and they were placed at six different locations on either state farms or a dry-farming experimental station. In each location the first group of access tubes were placed in fallow soil, the second in a wheat field and the third in a wheat field after harvest. Each treatment had three replicates. In all holes the moisture measurements were made at five different depths at intervals of either 15 days or one month. At the beginning of the moisture measurements a separate calibration curve was prepared for each location and for each treatment. The measurements were begun in 1964 and are continuing, but with some variations in the sampling technique. Some physical properties of the soils that were sampled from measurement areas, such as texture, field capacity and wilting point, were determined. Some bulk-density measurements were also made by gamma-ray transmission. The results obtained are averaged and illustrated in tables and figures. Necessary calculations and comparisons were made to show the efficiency of the fallow system in the moisture conservation in this dry soil. The results can be summarized as follows: (1) The total amount of water conserved in the soil down to a depth of 1.80 cm was higher in fallow soil than in the other two cases. This was true for all locations over a period of two years. (2) The amounts of water conserved by the effect of fallow

  6. On-irrigator pasture soil moisture sensor

    International Nuclear Information System (INIS)

    Tan, Adrian Eng-Choon; Richards, Sean; Platt, Ian; Woodhead, Ian

    2017-01-01

    In this paper, we presented the development of a proximal soil moisture sensor that measured the soil moisture content of dairy pasture directly from the boom of an irrigator. The proposed sensor was capable of soil moisture measurements at an accuracy of  ±5% volumetric moisture content, and at meter scale ground area resolutions. The sensor adopted techniques from the ultra-wideband radar to enable measurements of ground reflection at resolutions that are smaller than the antenna beamwidth of the sensor. An experimental prototype was developed for field measurements. Extensive field measurements using the developed prototype were conducted on grass pasture at different ground conditions to validate the accuracy of the sensor in performing soil moisture measurements. (paper)

  7. Radiometric measurement of ceramic material moisture

    International Nuclear Information System (INIS)

    Kominek, A.; Sojka, J.; Votava, P.

    1975-01-01

    Water content measurement using a neutron moisture meter has a long tradition in the CSSR. The method of water content determination using neutron and gamma radiation was developed by the Research Institute of Building Materials in Brno for a number of materials, as e.g. coke, brown coal semi-coke, anthracite, glass sand, dolomite, soda, gravel, aggregates, cement sludge, slag, brick clay, intermediate products of the ceramics industry, refractory building materials, etc. The water content measurement of ceramic materials for the manufacture of wall tiles was performed in a special equipment by detection of the slowed-down neutrons with an accuracy of +-0.6% water (within the range from 5 to 11%) and of materials for the manufacture of floor tiles by means of neutron and gamma radiation with an accuracy of +-0.4% water (within the range from 5 to 8%). (author)

  8. Cancer-meter: measure and cure.

    Science.gov (United States)

    Kashyap, Sunil Kumar; Sharma, Birendra Kumar; Banerjee, Amitabh

    2017-05-01

    This paper presents a theory and system on "Cancer-Meter'. This idea came through the statement that "cancer is curable if it is measurable". The Cancer-Meter proves that it is possible. This paper proposes the cancer-meter in two ways, theoretical and electronically, as per the measurement and treatment. By the mathematics, first part is defined but the second part is based on computer programming, electrical and electronics. Thus, the cancer-meter is a programmed-electrical-electronic device which measures and cures the cancer both.

  9. On-line measurement of moisture content of powdered food using microwave free-space transmission technique

    International Nuclear Information System (INIS)

    Kim, Ki Bok; Park, Seong Un; Kim, Ji Yeon; Kim, Jong Heon; Lee, ChanJoo

    2006-01-01

    The moisture content of food is not only the most important quality factor but also one of the essential parameters affecting their physical and chemical properties related to storage, capability of processing and quality control. The moisture measurement technique using microwave is very attractive because that method has merits of rapid and accurate measurement in the wider range of moisture content, simple implementation and inexpensive compared with other methods. In this study, microwave free-space transmission technique was applied to measure the moisture content of powdered food. The on-line measurement system consisting of microwave system with 2.5 GHz, 7.0 GHz and 10.5 GHz, conveying device to move the food samples, inlet and outlet of the food samples, guide plate to control the thickness of the food samples, temperature sensing nit, taco-meter and central processing unit having analog to digital convert and microprocessor was constructed and its performance was evaluated.

  10. The measuring system and practical uses of the universal radiation meter type TSM-11

    International Nuclear Information System (INIS)

    Rozsa, S.; Szabo, Gy.; Szem, I.; Vereczky, L.

    1980-01-01

    The industrial radiation meter in its signal conversion follows the ratemeter principle and uses pulse detectors. By its built-in zero suppression and scale extension the device makes the display of two pulses differing from each other at least by 10% and their conversion onto the output signal range of 0-20 mA possible. The information from the different measuring sections developed for industrial purposes are processed by the same device. The operation principles of and the experience gathered with the radiometer in its use in industry as density, level, thickness gauge, moisture and quantity meter and belt scales are discussed. (author)

  11. Opto-thermal moisture content and moisture depth profile measurements in organic materials

    NARCIS (Netherlands)

    Xiao, P.; Guo, X.; Cui, Y.Y.; Imhof, R.; Bicanic, D.D.

    2004-01-01

    Opto-thermal transient emission radiometry(OTTER) is a infrared remote sensing technique, which has been successfully used in in vivo skin moisture content and skin moisture depth profiling measurements.In present paper, we extend this moisture content measurement capability to analyze the moisture

  12. Moisture content measurement in paddy

    Science.gov (United States)

    Klomklao, P.; Kuntinugunetanon, S.; Wongkokua, W.

    2017-09-01

    Moisture content is an important quantity for agriculture product, especially in paddy. In principle, the moisture content can be measured by a gravimetric method which is a direct method. However, the gravimetric method is time-consuming. There are indirect methods such as resistance and capacitance methods. In this work, we developed an indirect method based on a 555 integrated circuit timer. The moisture content sensor was capacitive parallel plates using the dielectric constant property of the moisture. The instrument generated the output frequency that depended on the capacitance of the sensor. We fitted a linear relation between periods and moisture contents. The measurement results have a standard uncertainty of 1.23 % of the moisture content in the range of 14 % to 20 %.

  13. Moisture measurement in the iron and steel industry: experience with nuclear moisture measurements in coke, and studies of infrared moisture measurement of iron ore mixtures

    International Nuclear Information System (INIS)

    Beumer, J.A.; Wouters, M.

    1976-01-01

    In the heavy iron-making industry there are several processes for which it is necessary to measure on-line the moisture content of certain process materials, especially in the field of iron ore preparation and blast furnace practice. Two examples are given. (1) Experience with nuclear moisture-measurements in coke covers a period of ten years in which eight measuring systems have been installed in the weighing hoppers of blast furnaces. The standard deviation is about 0.7% moisture in the range 0 to 15% moisture. The way the method is used, the safety measures and the difficulties encountered, especially the effect on recalibration of neutron-absorbing materials in photomultipliers are described. (2) The application of infrared absorption to the study of moisture measurment or iron ore mixtures is described. With an ore mixture for pellets manufacture, a rather dark ore mixture, problems have arisen concerning the sensitivity. The reference and measuring wavelengths now in use are 2.51 and 2.95 μm. In this case the absorption of the energy is rather high. The results may be improved by using quartz optics instead of the normal Pyrex ones, as the cut-off wavelength of Pyrex is about 3 μm. Variations due to colour and specific surface have been studied. As the accuracy required is +- 0.1% moisture in the range 8 to 12% moisture, these variations need to be eliminated. (author)

  14. Guidance notes : safe practice for the use of nuclear density meters

    International Nuclear Information System (INIS)

    2000-06-01

    These 'Guidance notes' have been written to provide information for owners and users on the safe care and use of instruments containing radioactive materials used for the measurement of moisture content and/or density of materials. They give practical guidance on compliance with the requirements of radiation protection legislation and the 'Code of safe practice for the use of nuclear density meters, NRL C15'. Some of these instruments have been known as 'soil moisture gauges' and others as 'nuclear density meters' or just 'NDMs'. For simplicity, these 'Guidance notes' will follow industry terminology and use the term 'nuclear density meter'. Some parts of these 'Guidance notes' and of the 'Code, NRL C15' are relevant for users of asphalt gauges containing radioactive sources. These are normally laboratory bench instruments, and are not portable field instruments. Nevertheless, the radioactive sources used are similar to those used for moisture measurement and the safety implications are similar. The units of measurement of radioactivity and radiation dose are discussed in Appendix 1. Appendix 2 contains consent application forms while sample transport forms can be found in Appendix 3. (author). 10 refs

  15. development and testing of a capacitive digital soil moisture metre

    African Journals Online (AJOL)

    user

    soil moisture meter using the NE555 timer and micro controller as a major electronic component ... relationship between the moisture content process and the digital soil moisture meter. ..... the moisture contents showing that the infiltration of.

  16. In situ measurements for calculating evapotranspiration values using neutron moisture meter

    International Nuclear Information System (INIS)

    El-Gendy, R.W.; El-Moniem, M.; Massoud, M.

    2000-01-01

    Field experiment was conducted at the Wadi Sudr area, south Sinai, Egypt. Two types of residual animal farm (i.e., goat and camel)used wheat crop, beside control (no manure). The neutron scattering method and tensiometers were used to calculate the components of soil moisture depletion, evapotranspiration (ET) and drainage rate (DR). Evapotranspiration (ET) was determined by four methods, i.e, soil moisture depletion (SMD), Active rooting depth (ARD) at 80% SMD, active rooting depth (ARD) at zero hydraulic potential gradient (dh/dz = 0) and Blaney - Criddle formula (climatically data) using published crop coefficient (Kc) ET values for goat and camel residuals and control treatments were found to be 5.59, 5.54 and 6.80; 4.48, 4.43 and 5.44; 5.01, 4.11 and 11.66 and 4.5 mm day 1 for all treatments using the previous four methods respectively. The data obtained also showed that ET values under organic manure treatments were lower than control treatment, while the dry weight of wheat crop was higher in the manure-treated plots relative to the control. These less irrigation water requirements are needed to be applied to manure-treated plots and this should reduce the opportunity of soil deterioration if saline water is used

  17. Measurement of moisture motion under a temperature gradient in a concrete for SNR-300 using thermal neutrons

    International Nuclear Information System (INIS)

    Zelinger, A.

    1975-01-01

    For describing the behavior of the moisture in the concrete of the containment of SNR-300 in a hypothetical accident parameters were determined experimentally. The method is based on transmission of thermal neutrons through a plate of concrete. When a temperature of 170 deg C was applied at one end of the plate migration of moisture and evaporation took place. This could be observed by neutron radiography giving a gross picture of moisture migration. Furthermore the intensity of the transmitted neutron beam was measured with a neutron counter. From these values profiles of the change of moisture concentration could be obtained with a spatial resolution of few millimeters. The method used is entirely different from the conventional moisture meters which use fast neutrons. From the experimental data the mass transfer coefficient of vapour, the diffusion coefficient of vapour in concrete and the porosity of the concrete could be determined

  18. Comparison of time domain reflectometry, capacitance methods and neutron scattering in soil moisture measurements

    International Nuclear Information System (INIS)

    Khorasani, A.; Mousavi Shalmani, M. A.; Piervali Bieranvand, N.

    2011-01-01

    An accurate, precise, fast and ease as well as the ability for measurements in depth are the characteristics that are desirable in measuring soil moisture methods. To compare methods (time domain reflectometry and capacitance) with neutron scattering for soil water monitoring, an experiment was carried out in a randomized complete block design (Split Split plot) on tomato with three replications on the experimental field of International Atomic Energy Agency (Seibersdorf-Austria). The treatment instruments for the soil moisture monitoring (main factor) consist of neutron gauge, Diviner 2000, time domain reflectometer and an EnviroScan and different irrigation systems (first sub factor) consist of trickle and furrow irrigations and different depths of soil (second sub factor) consist of 0-20, 20-40 and 40-60 cm. The results showed that for the neutron gauge and time domain reflectometer the amount of soil moisture in both of trickle and furrow irrigations were the same, but the significant differences were recorded in Diviner 2000 and EnviroScan measurements. The results of this study showed that the neutron gauge is an acceptable and reliable means with the modern technology, with a precision of ±2 mm in 450 mm soil water to a depth of 1.5 meter and can be considered as the most practical method for measuring soil moisture profiles and irrigation planning program. The time domain reflectometer method in most mineral soils, without the need for calibration, with an accuracy ±0.01m 3 m -3 has a good performance in soil moisture and electrical conductivity measurements. The Diviner 2000 and EnviroScan are not well suitable for the above conditions for several reasons such as much higher soil moisture and a large error measurement and also its sensitivity to the soil gap and to the small change in the soil moisture in comparison with the neutron gauge and the time domain reflectometer methods.

  19. Assessment of the SMAP Passive Soil Moisture Product

    Science.gov (United States)

    Chan, Steven K.; Bindlish, Rajat; O'Neill, Peggy E.; Njoku, Eni; Jackson, Tom; Colliander, Andreas; Chen, Fan; Burgin, Mariko; Dunbar, Scott; Piepmeier, Jeffrey; hide

    2016-01-01

    The National Aeronautics and Space Administration (NASA) Soil Moisture Active Passive (SMAP) satellite mission was launched on January 31, 2015. The observatory was developed to provide global mapping of high-resolution soil moisture and freeze-thaw state every two to three days using an L-band (active) radar and an L-band (passive) radiometer. After an irrecoverable hardware failure of the radar on July 7, 2015, the radiometer-only soil moisture product became the only operational Level 2 soil moisture product for SMAP. The product provides soil moisture estimates posted on a 36 kilometer Earth-fixed grid produced using brightness temperature observations from descending passes. Within months after the commissioning of the SMAP radiometer, the product was assessed to have attained preliminary (beta) science quality, and data were released to the public for evaluation in September 2015. The product is available from the NASA Distributed Active Archive Center at the National Snow and Ice Data Center. This paper provides a summary of the Level 2 Passive Soil Moisture Product (L2_SM_P) and its validation against in situ ground measurements collected from different data sources. Initial in situ comparisons conducted between March 31, 2015 and October 26, 2015, at a limited number of core validation sites (CVSs) and several hundred sparse network points, indicate that the V-pol Single Channel Algorithm (SCA-V) currently delivers the best performance among algorithms considered for L2_SM_P, based on several metrics. The accuracy of the soil moisture retrievals averaged over the CVSs was 0.038 cubic meter per cubic meter unbiased root-mean-square difference (ubRMSD), which approaches the SMAP mission requirement of 0.040 cubic meter per cubic meter.

  20. The relationships between common measures of glucose meter performance.

    Science.gov (United States)

    Wilmoth, Daniel R

    2012-09-01

    Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. The relationships between common measures of glucose meter performance were derived mathematically. Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters. © 2012 Diabetes Technology Society.

  1. Measurement of soil moisture using gypsum blocks

    DEFF Research Database (Denmark)

    Friis Dela, B.

    the building. Consequently, measuring the moisture of the surrounding soil is of great importance for detecting the source of moisture in a building. Up till now, information has been needed to carry out individual calibrations for the different types of gypsum blocks available on the market and to account......For the past 50 years, gypsum blocks have been used to determine soil moisture content. This report describes a method for calibrating gypsum blocks for soil moisture measurements. Moisture conditions inside a building are strongly influenced by the moisture conditions in the soil surrounding...

  2. Liquid ultrasonic flow meters for crude oil measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kalivoda, Raymond J.; Lunde, Per

    2005-07-01

    Liquid ultrasonic flow meters (LUFMs) are gaining popularity for the accurate measurement of petroleum products. In North America the first edition of the API standard ''Measurement of liquid hydrocarbons by ultrasonic flow meters using transit time technology'' was issued in February 2005. It addresses both refined petroleum products and crude oil applications. Its field of application is mainly custody transfer applications but it does provide general guidelines for the installation and operation of LUFM's other applications such as allocation, check meters and leak detection. As with all new technologies performance claims are at times exaggerated or misunderstood and application knowledge is limited. Since ultrasonic meters have no moving parts they appear to have fewer limitations than other liquid flow meters. Liquids ultrasonic flow meters, like turbine meters, are sensitive to fluid properties. It is increasingly more difficult to apply on high viscosity products then on lighter hydrocarbon products. Therefore application data or experience on the measurement of refined or light crude oil may not necessarily be transferred to measuring medium to heavy crude oils. Before better and more quantitative knowledge is available on how LUFMs react on different fluids, the arguments advocating reduced need for in-situ proving and increased dependency on laboratory flow calibration (e.g. using water instead of hydrocarbons) may be questionable. The present paper explores the accurate measurement of crude oil with liquid ultrasonic meters. It defines the unique characteristics of the different API grades of crude oils and how they can affect the accuracy of the liquid ultrasonic measurement. Flow testing results using a new LUFM design are discussed. The paper is intended to provide increased insight into the potentials and limitations of crude oil measurement using ultrasonic flow meters. (author) (tk)

  3. High resolution soil moisture radiometer. [large space structures

    Science.gov (United States)

    Wilheit, T. T.

    1978-01-01

    An electrically scanned pushbroom phased antenna array is described for a microwave radiometer which can provide agriculturally meaningful measurements of soil moisture. The antenna size of 100 meters at 1400 MHz or 230 meters at 611 MHz requires several shuttle launches and orbital assembly. Problems inherent to the size of the structure and specific instrument problems are discussed as well as the preliminary design.

  4. Net metering study of switching effects on electromechanical meters[Report prepared for the Measurement Canada Electricity Net Metering Project

    Energy Technology Data Exchange (ETDEWEB)

    Van Overberghe, L. [Measurement Canada, London, ON (Canada)

    2006-03-03

    The feasibility of introducing net metering in the electricity sector was evaluated with particular reference to a project administered by Measurement Canada and Electro-Federation Canada (MicroPower Connect) in collaboration with Natural Resources Canada. The objective of the Measurement Canada Electricity Net Metering Project is to identify and eliminate the barriers introduced by the Electricity and Gas Inspection Act regarding the introduction of net metering. The purpose was to design a device that would allow rotation reversal in a residential electromechanical single phase meter. The device should approximate any fluctuations found in a typical net metering system. A series of tests were conducted to understand the influences, on errors, of forward-to-reverse and reverse-to-forward transitions, specifically to find evidence of error migration and mechanical stress. The project was designed to find and measure the effects of forward reverse switching on an electromechanical meter resulting from a change in energy flow. Twenty metres were calibrated in the forward direction in series from light load to high load. Power factor was not adjustable. Test points were then applied in both the forward and reverse directions. The exercise yielded individual errors which were aggregated to show average found errors after 3,000 transitions. Small shifts in errors were apparent and there was no evidence to support a disk flutter theory. refs., tabs., figs.

  5. Analysis and optimal design of moisture sensor for rice grain moisture measurement

    Science.gov (United States)

    Jain, Sweety; Mishra, Pankaj Kumar; Thakare, Vandana Vikas

    2018-04-01

    The analysis and design of a microstrip sensor for accurate determination of moisture content (MC) in rice grains based on oven drying technique, this technique is easy, fast and less time-consuming to other techniques. The sensor is designed with low insertion loss, reflection coefficient and maximum gain is -35dB and 5.88dB at 2.68GHz as well as discussed all the parameters such as axial ratio, maximum gain, smith chart etc, which is helpful for analysis the moisture measurement. The variation in percentage of moisture measurement with magnitude and phase of transmission coefficient is investigated at selected frequencies. The microstrip moisture sensor consists of one layer: substrate FR4, thickness 1.638 is simulated by computer simulated technology microwave studio (CST MWS). It is concluded that the proposed sensor is suitable for development as a complete sensor and to estimate the optimum moisture content of rice grains with accurately, sensitivity, compact, versatile and suitable for determining the moisture content of other crops and agriculture products.

  6. 7 CFR 868.258 - Moisture.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Moisture. 868.258 Section 868.258 Agriculture... Governing Application of Standards § 868.258 Moisture. Water content in brown rice for processing as... purpose of this paragraph, “approved device” shall include the Motomco Moisture Meter and any other...

  7. New method measures moisture and true dry mass

    International Nuclear Information System (INIS)

    Frank, H.

    The moisture content of wood can be determined by measuring the nuclear magnetic resonance of free water hydrogen atoms in wood. Nanassy studied NMR curves for six types of wood and obtained the calibration curve by reducing the moisture content in steps by 4% moisture down to ca. 1% moisture and then by gradually wetting the wood. The initial material was fresh wood. For each step he measured the intensity of the free water hydrogen signal. If the sample weight is known the dry matter content (dry weight) and moisture content of the sample can be derived from the measured NMR signal. (J.P.)

  8. EDITORIAL: Microwave Moisture Measurements

    Science.gov (United States)

    Kaatze, Udo; Kupfer, Klaus; Hübner, Christof

    2007-04-01

    Microwave moisture measurements refer to a methodology by which the water content of materials is non-invasively determined using electromagnetic fields of radio and microwave frequencies. Being the omnipresent liquid on our planet, water occurs as a component in most materials and often exercises a significant influence on their properties. Precise measurements of the water content are thus extremely useful in pure sciences, particularly in biochemistry and biophysics. They are likewise important in many agricultural, technical and industrial fields. Applications are broad and diverse, and include the quality assessment of foodstuffs, the determination of water content in paper, cardboard and textile production, the monitoring of moisture in sands, gravels, soils and constructions, as well as the measurement of water admixtures to coal and crude oil in reservoirs and in pipelines. Microwave moisture measurements and evaluations require insights in various disciplines, such as materials science, dielectrics, the physical chemistry of water, electrodynamics and microwave techniques. The cooperation of experts from the different fields of science is thus necessary for the efficient development of this complex discipline. In order to advance cooperation the Workshop on Electromagnetic Wave Interaction with Water and Moist Substances was held in 1993 in Atlanta. It initiated a series of international conferences, of which the last one was held in 2005 in Weimar. The meeting brought together 130 scientists and engineers from all over the world. This special issue presents a collection of some selected papers that were given at the event. The papers cover most topics of the conference, featuring dielectric properties of aqueous materials, electromagnetic wave interactions, measurement methods and sensors, and various applications. The special issue is dedicated to Dr Andrzej W Kraszewski, who died in July 2006 after a distinguished career of 48 years in the research of

  9. 7 CFR 868.207 - Moisture.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Moisture. 868.207 Section 868.207 Agriculture... Application of Standards § 868.207 Moisture. Water content in rough rice as determined by an approved device..., “approved device” shall include the Motomco Moisture Meter and any other equipment that is approved by the...

  10. Neutron moisture measurement in materials

    International Nuclear Information System (INIS)

    Thony, J.L.

    1985-01-01

    This method is generally used for soil moisture determination but also for moisture in building materials. After a review of neutron interaction with matter (elastic and inelastic scattering, radiative capture and absorption with emission of charged particles) and of the equipment (source, detector and counting), gravimetric and chemical calibration are described and accuracy of measurement is discussed. 5 refs [fr

  11. Surface Moisture Measurement System Operation and Maintenance Manual

    International Nuclear Information System (INIS)

    Ritter, G.A.; Pearce, K.L.; Stokes, T.L.

    1995-12-01

    This operations and maintenance manual addresses deployment, equipment and field hazards, operating instructions, calibration verification, removal, maintenance, and other pertinent information necessary to safely operate and store the Surface Moisture Measurement System (SMMS) and Liquid Observation Well Moisture Measurement System (LOWMMS). These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  12. COSMOS: the COsmic-ray Soil Moisture Observing System

    Directory of Open Access Journals (Sweden)

    M. Zreda

    2012-11-01

    Full Text Available The newly-developed cosmic-ray method for measuring area-average soil moisture at the hectometer horizontal scale is being implemented in the COsmic-ray Soil Moisture Observing System (or the COSMOS. The stationary cosmic-ray soil moisture probe measures the neutrons that are generated by cosmic rays within air and soil and other materials, moderated by mainly hydrogen atoms located primarily in soil water, and emitted to the atmosphere where they mix instantaneously at a scale of hundreds of meters and whose density is inversely correlated with soil moisture. The COSMOS has already deployed more than 50 of the eventual 500 cosmic-ray probes, distributed mainly in the USA, each generating a time series of average soil moisture over its horizontal footprint, with similar networks coming into existence around the world. This paper is written to serve a community need to better understand this novel method and the COSMOS project. We describe the cosmic-ray soil moisture measurement method, the instrument and its calibration, the design, data processing and dissemination used in the COSMOS project, and give example time series of soil moisture obtained from COSMOS probes.

  13. Simple grain moisture content determination from microwave measurements

    International Nuclear Information System (INIS)

    Kraszewski, A.W.; Trabelsi, S.; Nelson, S.O.

    1998-01-01

    Moisture content of wheat, Triticum aestivum L., is expressed as a function of the ratio of microwave attenuation and phase shift, measured at 16.8 GHz, and grain temperature. Validation of the calibration equation indicated that moisture content was obtained with an uncertainty less than +/- 0.45% moisture at the 95% confidence level, independent of density variation, at temperatures from -1 degree C to 42 degrees C, and moisture contents from 10% to 19%. Moisture determination does not depend on the layer thickness of the wheat norits bulk density. No differences between two wheat cultivars were observed in the measurement data

  14. Service Life Prediction of Wood Claddings by in-situ Measurement of Wood Moisture Content

    DEFF Research Database (Denmark)

    Engelund, Emil Tang; Lindegaard, Berit; Morsing, Niels

    2009-01-01

    of wood moisture are done by in-situ resistance moisture meters (Lindegaard and Morsing 2006). The aim is that the test should form the basis of evaluation of the maintenance requirements and the prediction of service life of the surface treatment and the wood/construction. At the moment 60 test racks...... are exposed. This study examines the data from the first five years of outdoor exposure using data from a test rack with a water-borne acrylic coating and a test rack with ICP coating for case studies. The moisture content data was converted into weekly average and weekly variation values which gave a deeper...

  15. Passive Rn dose meters - measuring methods appropriate for large measurement series

    International Nuclear Information System (INIS)

    Urban, M.; Kiefer, H.

    1985-01-01

    Passive integrating measuring methods can be classified in several groups by their functioning principle, e.g. spray chambers or open chambers with nuclear trace detectors or TL detectors, open detectors, activated carbon dose meters with or without TL detectors. According to the functioning principle, only radon or radon and fission products can be detected. The lecture gives a survey of the present state of development of passive Rn dose meters. By the example of the Ra dose meter developed at Karlsruhe which was used in inquiry measurements carried out in Germany, Switzerland, the Netherlands, Belgium and Austria, etching technology, estimation of measuring uncertainties, reproducibility and fading behaviour shall be discussed. (orig./HP) [de

  16. Rapid and accurate biofuel moisture content gauging using magnetic resonance measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Jaervinen, T.

    2013-04-15

    Biomass is extensively utilised in energy production and as a raw material, such as for the production of liquid biofuels. All those processes will benefit if the moisture content of bio material is known in advance as accurately as possible under transient circumstances. Biofuel trade is increasingly based on the calorific value of fuels. In the first step, this also increases the need for rapid and accurate moisture content determination. During the last few years, large biofuel standardisation has been implemented, emphasising biofuel quality control at all stages of the utilisation chain. In principle, the moisture instrumental measurement can be utilised by many technologies and procedures. Typical techniques are infrared, radiofrequency, microwave, radiometric, electrical conductivity, capacitance, and impedance. Nuclear magnetic resonance (MR) and thermal neutron absorption are also applied. The MR measurement principle has been known and utilised already since the early 1950s. It has become the basic instrumental analysis tool in chemistry. It is also well-known as a very accurate method for analysing most compounds, especially substances containing hydrogen. The utilisation of MR metering is expanded extensively to medical diagnostics as a form of magnetic resonance imaging (MRI). Because of the precision of the MR principle, there have for a long time been efforts to apply it in new and different areas, and to make more user-friendly, smaller, and even portable devices. Such a device was designed by Vaisala a few years ago. VTT has utilised Vaisala's MR prototype for approximately one year for moisture content measurement of different biofuels. The first step in the use of an MR device for moisture determination was the definition of its measurement accuracy compared to the standard method (EN 14774). Those tests proved that the absolute precision seems to be comparable to the standard moisture content measurement method. It was also found out that

  17. An overview of the measurements of soil moisture and modeling of moisture flux in FIFE

    Science.gov (United States)

    Wang, J. R.

    1992-01-01

    Measurements of soil moisture and calculations of moisture transfer in the soil medium and at the air-soil interface were performed over a 15-km by 15-km test site during FIFE in 1987 and 1989. The measurements included intensive soil moisture sampling at the ground level and surveys at aircraft altitudes by several passive and active microwave sensors as well as a gamma radiation device.

  18. Investigation of Seepage Meter Measurements in Steady Flow and Wave Conditions.

    Science.gov (United States)

    Russoniello, Christopher J; Michael, Holly A

    2015-01-01

    Water exchange between surface water and groundwater can modulate or generate ecologically important fluxes of solutes across the sediment-water interface. Seepage meters can directly measure fluid flux, but mechanical resistance and surface water dynamics may lead to inaccurate measurements. Tank experiments were conducted to determine effects of mechanical resistance on measurement efficiency and occurrence of directional asymmetry that could lead to erroneous net flux measurements. Seepage meter efficiency was high (average of 93%) and consistent for inflow and outflow under steady flow conditions. Wave effects on seepage meter measurements were investigated in a wave flume. Seepage meter net flux measurements averaged 0.08 cm/h-greater than the expected net-zero flux, but significantly less than theoretical wave-driven unidirectional discharge or recharge. Calculations of unidirectional flux from pressure measurements (Darcy flux) and theory matched well for a ratio of wave length to water depth less than 5, but not when this ratio was greater. Both were higher than seepage meter measurements of unidirectional flux made with one-way valves. Discharge averaged 23% greater than recharge in both seepage meter measurements and Darcy calculations of unidirectional flux. Removal of the collection bag reduced this net discharge. The presence of a seepage meter reduced the amplitude of pressure signals at the bed and resulted in a nearly uniform pressure distribution beneath the seepage meter. These results show that seepage meters may provide accurate measurements of both discharge and recharge under steady flow conditions and illustrate the potential measurement errors associated with dynamic wave environments. © 2014, National Ground Water Association.

  19. Photon and neutron doses of the personnel using moisture and density measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V. [Greek Atomic Energy Commission, Agia Paraskevi, Attiki, 60092 (Greece)

    2006-07-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a {sup 137}Cs source for density measurements and an {sup 241}Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  20. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  1. Use a microwave oven to determine the moisture content of sunflower

    International Nuclear Information System (INIS)

    Backer, L.F.; Walz, A.W.

    1987-01-01

    Much of the sunflower crop in the major producing areas of the United States requires artificial drying because of late crop maturity. Plant growth regulators permit earlier harvest by accelerating the maturation rate of the plant; research indicates that use of the growth regulator would result in approximately 10-14 days earlier maturation. Effectiveness of the chemical is dependent on timely application at relatively high moisture contents (50 to 55 percent). A rapid means of determining seed moisture content is required so the chemical can be applied at the proper growth stage . Additionally, sunflower is often harvested at moisture contents of more than 17 percent. Most electronic moisture meters are not calibrated for moisture contents this high and the accuracy of most moisture meters decreases with increasing moisture content. A recent study has shown that a conventional microwave oven can successfully be used to very rapidly determine the moisture content of high moisture sunflower seeds to indicate proper growth stage for the application of plant growth regulators. The microwave oven could also be used with reasonable accuracy to check harvest moisture content down to about 15 percent. At lower moisture contents, it would be advisable to use a calibrated electronic moisture meter

  2. Microwave emission measurements of sea surface roughness, soil moisture, and sea ice structure

    Science.gov (United States)

    Gloersen, P.; Wilheit, T. T.; Schmugge, T. J.

    1972-01-01

    In order to demonstrate the feasibility of the microwave radiometers to be carried aboard the Nimbus 5 and 6 satellites and proposed for one of the earth observatory satellites, remote measurements of microwave radiation at wavelengths ranging from 0.8 to 21 cm have been made of a variety of the earth's surfaces from the NASA CV-990 A/C. Brightness temperatures of sea water surfaces of varying roughness, of terrain with varying soil moisture, and of sea ice of varying structure were observed. In each case, around truth information was available for correlation with the microwave brightness temperature. The utility of passive microwave radiometry in determining ocean surface wind speeds, at least for values higher than 7 meters/second has been demonstrated. In addition, it was shown that radiometric signatures can be used to determine soil moisture in unvegetated terrain to within five percentage points by weight. Finally, it was demonstrated that first year thick, multi-year, and first year thin sea ice can be distinguished by observing their differing microwave emissivities at various wavelengths.

  3. Calibration of quantitative neutron radiography method for moisture measurement

    International Nuclear Information System (INIS)

    Nemec, T.; Jeraj, R.

    1999-01-01

    Quantitative measurements of moisture and hydrogenous matter in building materials by neutron radiography (NR) are regularly performed at TRIGA Mark II research of 'Jozef Stefan' Institute in Ljubljana. Calibration of quantitative method is performed using standard brick samples with known moisture content and also with a secondary standard, plexiglas step wedge. In general, the contribution of scattered neutrons to the neutron image is not determined explicitly what introduces an error to the measured signal. Influence of scattered neutrons is significant in regions with high gradients of moisture concentrations, where the build up of scattered neutrons causes distortion of the moisture concentration profile. In this paper detailed analysis of validity of our calibration method for different geometrical parameters is presented. The error in the measured hydrogen concentration is evaluated by an experiment and compared with results obtained by Monte Carlo calculation with computer code MCNP 4B. Optimal conditions are determined for quantitative moisture measurements in order to minimize the error due to scattered neutrons. The method is tested on concrete samples with high moisture content.(author)

  4. Development of the neutron technology for measuring the moisture content in China

    International Nuclear Information System (INIS)

    Zhao Jingwu; Liu Shengkang; Zhang Zhiping

    2011-01-01

    According to measuring mode (in-hopper, surface, sampling neutron moisture gauge), the development and application of neutron moisture gauge in china were introduced, which include the following course from only measuring moisture content of soil to monitoring moisture content of farmland and saving water for irrigating farmland, from measuring moisture content of pellet to coke and coal material, from only measuring moisture content to computerized neutron moisture gauges with density compensation and o f high precision. (authors)

  5. Optimal leaf positions for chlorophyll meter measurement in rice

    Directory of Open Access Journals (Sweden)

    Zhaofeng eYuan

    2016-05-01

    Full Text Available The Soil Plant Analysis Development (SPAD chlorophyll meter is one of the most commonly used diagnostic tools to measure crop nitrogen status. However, the measurement method of the meter could significantly affect the accuracy of the final estimation. Thus, this research was undertaken to develop a new methodology to optimize SPAD meter measurements in rice (Oryza sativa L.. A flatbed color scanner was used to map the dynamic chlorophyll distribution and irregular leaf shapes. Calculus algorithm was adopted to estimate the potential positions for SPAD meter measurement along the leaf blade. Data generated by the flatbed color scanner and SPAD meter were analysed simultaneously. The results suggested that a position 2/3 of the distance from the leaf base to the apex (2/3 position could represent the chlorophyll content of the entire leaf blade, as indicated by the relatively low variance of measurements at that positon. SPAD values based on di-positional leaves and the extracted chlorophyll a and b contents were compared. This comparison showed that the 2/3 position on the lower leaves tended to be more sensitive to changes in chlorophyll content. Finally, the 2/3 position and average SPAD values of the fourth fully expanded leaf from the top were compared with leaf nitrogen concentration. The results showed the 2/3 position on that leaf was most suitable for predicting the nitrogen status of rice. Based on these results, we recommend making SPAD measurements at the 2/3 position on the fourth fully expanded leaf from the top. The coupling of dynamic chlorophyll distribution and irregular leaf shapes information can provide a promising approach for the calibration of SPAD meter measurement, which can further benefit the in situ nitrogen management by providing reliable estimation of crops nitrogen nutrition status.

  6. Radar for Measuring Soil Moisture Under Vegetation

    Science.gov (United States)

    Moghaddam, Mahta; Moller, Delwyn; Rodriguez, Ernesto; Rahmat-Samii, Yahya

    2004-01-01

    A two-frequency, polarimetric, spaceborne synthetic-aperture radar (SAR) system has been proposed for measuring the moisture content of soil as a function of depth, even in the presence of overlying vegetation. These measurements are needed because data on soil moisture under vegetation canopies are not available now and are necessary for completing mathematical models of global energy and water balance with major implications for global variations in weather and climate.

  7. Moisture measurements in building materials with microwaves; Rakennusmateriaalien kosteusmittauksia mikroaalloilla

    Energy Technology Data Exchange (ETDEWEB)

    Kaeaeriaeinen, H.; Rudolph, M.; Schaurich, D.; Wiggenhauser, H. [VTT Building Technology, Espoo (Finland). Construction and Facility Management

    1998-12-01

    In order to assess the condition and evaluate the reliability of buildings and structures, it is essential to establish the moisture condition of the floor and other structural elements of the building. NDT-methods are increasingly being used for such moisture measurements because they do not cause any damage to the building under investigation. Microwave transmission is one of the NDT-methods and has been in use for several years. In this report, the applicability of the microwave method for measuring moisture in different building materials was investigated. This method has been successfully used at BAM for repeated moisture measurements in brick and sandstone material. This project also included other materials, such as concrete, sand, gravel, insulation and wood. At the same time, information was gathered about in situ moisture determination of building materials with a microwave moisture measuring system. The equipment used in this research has been developed at BAM over the last few years. The method requires two parallel boreholes in the specimen in which two microwave antennae can be moved. The moisture content in the material can be calculated from the microwave intensity transmitted between the two boreholes. Moisture profiles along the boreholes can be obtained by moving the antennae in steps along the length of the boreholes and taking measurements at each step. Special care must be taken while drilling the holes for the antennae, as this process must not affect the moisture condition in the specimen, and the boreholes must be made as parallel to each other as possible. The microwave frequencies used in the laboratory measurements ranged from 8 to 16,5 GHz in steps of 0,5 GHz. The diameters of the antennae were between 7 and 9 mm, and of the boreholes between 8 and 12 mm. Except for the concrete specimen, all the specimens were measured using plastic tubes in the boreholes. The moisture content measured by the microwave technique was verified by the

  8. development and testing of a capacitive digital soil moisture metre

    African Journals Online (AJOL)

    This paper presents a low cost, simple digital soil moisture meter, working on the principle of dielectric. A digital soil moisture meter using the NE555 timer and micro controller as a major electronic component was developed and tested, which display its output in a range of 0.0 to 99% on the 7-segment displayed unit.

  9. Moisture assessment by fast and non-destructive in situ measurements

    DEFF Research Database (Denmark)

    Hansen, Kurt Kielsgaard; Møller, Eva B.; Hansen, Ernst Jan de Place

    2014-01-01

    moisture content, which is not revealed by this inspection. The moisture content may become a problem for the buyers. This problem might have been avoided if the moisture content of the Building materials was measured on inspection. This is easily done in wood-based materials but for example in concrete...... to use, easily applicable and suitable for most porous building materials. Furthermore, the measurements must be reliable at the high end of the hygroscopic area and describe absolute moisture content or corresponding relative humidity. The existing methods for moisture measuring cannot meet...... on measurements of the relative humidity of the air in a small hood placed tightly and sealed to the surface of the construction. Results with aerated concrete covered with acrylic paint are presented....

  10. Optical transparency of paper as a function of moisture content with applications to moisture measurement.

    Science.gov (United States)

    Forughi, A F; Green, S I; Stoeber, B

    2016-02-01

    Accurate measurement of the moisture content of paper is essential in papermaking and is also important in some paper-based microfluidic devices. Traditional measurement techniques provide very limited spatiotemporal resolution and working range. This article presents a novel method for moisture content measurement whose operating principle is the strong correlation between the optical transparency of paper and its moisture content. Spectrographic and microscopic measurement techniques were employed to characterize the relation of moisture content and relative transparency of four types of paper: hardwood chemi-thermomechanical pulp paper, Northern bleached softwood kraft paper, unbleached softwood kraft paper, and General Electric(®) Whatman™ grade 1 chromatography paper. It was found that for all paper types, the paper transparency increased monotonically with the moisture content (as the ratio of the mass-of-water to the mass-of-dry-paper increased from 0% to 120%). This significant increase in relative transparency occurred due to the refractive index matching role of water in wet paper. It is further shown that mechanical loading of the paper has little impact on the relative transparency, for loadings that would be typical on a paper machine. The results of two transient water absorption experiments are presented that show the utility and accuracy of the technique.

  11. Weak measurements with a qubit meter

    DEFF Research Database (Denmark)

    Wu, Shengjun; Mølmer, Klaus

    2009-01-01

    We derive schemes to measure the so-called weak values of quantum system observables by coupling of the system to a qubit meter system. We highlight, in particular, the meaning of the imaginary part of the weak values, and show how it can be measured directly on equal footing with the real part...

  12. Measured moisture in buildings and adverse health effects: a review.

    Science.gov (United States)

    Mendell, Mark J; Macher, Janet M; Kumagai, Kazukiyo

    2018-04-23

    It has not yet been possible to quantify dose-related health risks attributable to indoor dampness or mold (D/M), to support the setting of health-related limits for D/M. An overlooked target for assessing D/M is moisture in building materials, the critical factor allowing microbial growth. A search for studies of quantified building moisture and occupant health effects identified three eligible studies. Two studies assessed associations between measured wall moisture content and respiratory health in the UK. Both reported dose-related increases in asthma exacerbation with higher measured moisture, with one study reporting an adjusted odds ratio (OR) of 7.0 for night-time asthma symptoms with higher bedroom moisture. The third study assessed relationships between infrared camera-determined wall moisture and atopic dermatitis in South Korea, reporting an adjusted OR of 14.5 for water-damaged homes and moderate or severe atopic dermatitis. Measuring building moisture has, despite extremely limited available findings, potential promise for detecting unhealthy D/M in homes and merits more research attention. Further research to validate these findings should include measured "water activity," which directly assesses moisture availability for microbial growth. Ultimately, evidence-based, health-related thresholds for building moisture, across specific materials and measurement devices, could better guide assessment and remediation of D/M in buildings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  13. ARPANSA preliminary measurements of radiofrequency transmissions from a Mesh Radio Smart meter

    International Nuclear Information System (INIS)

    Wijayasinghe, Don; Karipidis, Ken

    2013-01-01

    Smart meters have been deployed in buildings initially in Victoria and increasingly across other areas of Australia. They utilise radiofrequency (RF) electromagnetic energy (EME) at levels very much below the levels permitted in the RF Standard. Despite the low levels of RF EME, there is some public concern about exposures from smart meters and whether the RF transmissions may cause a variety of health effects. ARPANSA has undertaken some preliminary RF measurements of an installed mesh network smart meter at the home of a staff member in a suburb of Melbourne. It must be emphasised that these measurements by ARPANSA cannot be considered representative of all smart meters. A typical RF pulse from the smart meter had an average intensity of 7 mW/m 2 measured at a distance of half a metre from the smart meter with the door to the meter box open. This is 0.00015% of the instantaneous exposure limit in the Australian RF standard for the general public. The measured level with the meter box door closed, or on the other side of the wall on which the meter was mounted was about 20 times lower. The RF transmissions that were measured were not continuous and occurred less than 0.08% of the time that the measurements took place. The RF electromagnetic energy transmitted in a single pulse from the smart meter is similar to that from a car remote unlocking fob and much less than a single GSM SMS transmission. The measurements do not provide any indication of why smart meter transmissions would provoke symptoms in people otherwise unaffected by other wireless technologies such as mobile phone handsets. Indeed the low levels and short transmission times make any effects highly unlikely.

  14. Space-time modeling of soil moisture

    Science.gov (United States)

    Chen, Zijuan; Mohanty, Binayak P.; Rodriguez-Iturbe, Ignacio

    2017-11-01

    A physically derived space-time mathematical representation of the soil moisture field is carried out via the soil moisture balance equation driven by stochastic rainfall forcing. The model incorporates spatial diffusion and in its original version, it is shown to be unable to reproduce the relative fast decay in the spatial correlation functions observed in empirical data. This decay resulting from variations in local topography as well as in local soil and vegetation conditions is well reproduced via a jitter process acting multiplicatively over the space-time soil moisture field. The jitter is a multiplicative noise acting on the soil moisture dynamics with the objective to deflate its correlation structure at small spatial scales which are not embedded in the probabilistic structure of the rainfall process that drives the dynamics. These scales of order of several meters to several hundred meters are of great importance in ecohydrologic dynamics. Properties of space-time correlation functions and spectral densities of the model with jitter are explored analytically, and the influence of the jitter parameters, reflecting variabilities of soil moisture at different spatial and temporal scales, is investigated. A case study fitting the derived model to a soil moisture dataset is presented in detail.

  15. Avaliação do teor de umidade da madeira de Eucalyptus grandis por medidores elétricos resistivos. Evaluation of the Eucalyptus grandis lumber moisture content by resistancetype moisture meters.

    Directory of Open Access Journals (Sweden)

    João Eduardo Guarnetti dos SANTOS

    2006-01-01

    Full Text Available O presente estudo teve como objetivoverificar a precisão de dois tipos de medidoreselétricos de teor de umidade durante o processo desecagem da madeira de Eucalyptus grandis. Foramretiradas amostras representativas de 14 tábuas deEucalyptus grandis e secas em estufa elétrica a40 ºC de temperatura, até que o material atingisse10% de umidade. Durante a secagem foramdeterminados, periodicamente, o teor de umidadeatravés do método de massas correntes e deverificações simultâneas com um medidor elétricoportátil (EMM e com o sistema de controle de umsecador convencional (KCS. Os resultados mostraramque: (1 o sensor de umidade KCS pode substituiro método gravimétrico durante a secagem damadeira; (2 o medidor do teor de umidade EMMsubestima os reais teores de umidade durante asecagem da madeira e não é indicado parasubstituir o método gravimétrico de determinação de umidade.The aim of the study was to evaluate theprecision of two types of electric moisture metersduring the drying process of Eucalyptus grandisboards. Samples were obtained from 14 boards ofEucalyptus grandis and they were dried in electriclaboratory oven at 40 ºC of temperature, until thewood achieve 10% of moisture content. During thedrying, the moisture content was determined bygravimetric method and simultaneous checks by anelectric moisture meter (EMM and by kilncontrol system (KCS. The results showed that:(1 the KCS can replace the gravimetric methodduring the wood drying; (2 the EMMunderestimate the real moisture content during thedrying of boards and it is not indicate as substituteof the gravimetric method.

  16. Effect of Smart Meter Measurements Data On Distribution State Estimation

    DEFF Research Database (Denmark)

    Pokhrel, Basanta Raj; Nainar, Karthikeyan; Bak-Jensen, Birgitte

    2018-01-01

    Smart distribution grids with renewable energy based generators and demand response resources (DRR) requires accurate state estimators for real time control. Distribution grid state estimators are normally based on accumulated smart meter measurements. However, increase of measurements in the phy......Smart distribution grids with renewable energy based generators and demand response resources (DRR) requires accurate state estimators for real time control. Distribution grid state estimators are normally based on accumulated smart meter measurements. However, increase of measurements...... in the physical grid can enforce significant stress not only on the communication infrastructure but also in the control algorithms. This paper aims to propose a methodology to analyze needed real time smart meter data from low voltage distribution grids and their applicability in distribution state estimation...

  17. Development of nuclear density and moisture gauges

    International Nuclear Information System (INIS)

    Zhu Huaian; Zhu Dichen; Jiang Yulan; Yin Xiling; Li Jianwen; Cheng Jianbing; Yan Haiqing

    1993-01-01

    The model MT5012 nuclear density and moisture gauge is an advanced portable meter to inspect the compactness of a highway roadbed and pavement foundation. It has perfect functions and the advantage of quickness, accuracy and non-destruction. It is also applicable to civil engineering, such as railway, airport and embankment. The model MT5022 nuclear density and moisture gauge is a mobile meter for continuous inspection and control of the compactness of a highway and pavement foundation. It can be installed on road roller, wheelbarrow and other traffic machines while working, and is more efficient than the portable ones

  18. Use of Ultrasonic Technology for Soil Moisture Measurement

    Science.gov (United States)

    Choi, J.; Metzl, R.; Aggarwal, M. D.; Belisle, W.; Coleman, T.

    1997-01-01

    In an effort to improve existing soil moisture measurement techniques or find new techniques using physics principles, a new technique is presented in this paper using ultrasonic techniques. It has been found that ultrasonic velocity changes as the moisture content changes. Preliminary values of velocities are 676.1 m/s in dry soil and 356.8 m/s in 100% moist soils. Intermediate values can be calibrated to give exact values for the moisture content in an unknown sample.

  19. Application of model MTS5 dew-point meter in gas sampling and analyzing system of HTR-10

    International Nuclear Information System (INIS)

    Zhu Jiang; Li Zhihui

    2010-01-01

    The feature of humidity detector to measure the content of water in pure helium of main loop of reactor was discussed, and the circumstances using Al 2 O 3 moisture sensor to measure the content of water in helium on-line were introduced. During those few years, the dew-point meter has sufficed to measure the content of water in the helium gas during the running of the reactor. On the other hand, excursion can happen when the instrument running. Demarcate must be made periodically to improve the veracity of the meter. (authors)

  20. Measuring of moisture content in biofuel; Fukthaltsmaetning av biobraensle

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Lars; Njurell, Rolf; Ehleskog, Rickard [AaF Energikonsult AB, Stockholm (Sweden)

    2002-04-01

    Direct determination of the moisture content, i.e. analysis of the fuel, is the most dominating moisture measuring method of today, and is usually done manually by weighing and drying a sample. By measuring on the exhaust gases the moisture content is determined indirect. This method is based upon the fact that there is a relation between the moisture content in the fuel and in the exhaust gases. This is an alternative that is only considered briefly in this report. Acceptance test of the fuel today takes place in several ways. The methods vary from advanced automatic mechanical devices to manually taken tests made by the driver him self. In the simplest case when the plant only has one fuel supplier, deduction is maid against the amount of produced energy. There are no systems today that can automatically take tests for continuous measuring. This project aims to find methods that are practical for direct, automatic and continuous measurement of the moisture content for the following applications: Moisture determination of fuel supplies, acceptance test. Moisture determination for combustion control in furnaces and boilers. The possibilities to automate the sampling are discussed in detail, at which important background information concerning the handling problems associated with the point of measuring is illustrated. The measurement techniques that are described more in detail are NIR (Near Infra Red), radar technique, microwave technique, radio frequency scan, radioactive technique, double energy X-ray and some combinations of these techniques. In the report, suppliers of interesting instruments are presented. The fundamental technical demands and the basis that should be included in a specification of a measuring device are gathered. Our appraisal is that a sequel to this project should be concentrated on the following main issues: Automatic acceptance test: The measuring is suggested to be done with a test probe direct in the incoming batch. The most suited

  1. Soil moisture transport during the 1974--1975 and 1975--1976 water years

    International Nuclear Information System (INIS)

    Last, G.V.; Easley, P.G.; Brown, D.J.

    1976-12-01

    The rate and direction of soil moisture movement in Hanford sediments were determined for the 1974-1975 and 1975-1976 water years. The data for these determinations was obtained from two large lysimeters located on the 200 area plateau near the center of the Hanford Reservation. During the 1974-75 water year, meteoric moisture percolated to a depth of 2.5 meters with a peak moisture content of 10.5 volume-percent. This percolation envelope was eliminated by evaporation during the hot dry summer of 1975. The 1975-76 water year had only 70 percent of the normal precipitation, thus the percolation envelope was small and penetrated to a depth of only two meters. However, in spite of this shallow depth and low volume of moisture, the percolation envelope was not eliminated by the end of the water year because of lower seasonal temperatures and higher humidity during the drying season. Moisture content of sediments in the 4-18 meter depth range showed no relative change throughout the two water years, and no moisture accumulated at the bottom of the lysimeters, which indicates there is no deep percolation of meteoric moisture at this site, and no recharge to the ground water

  2. Microwave radiometric measurements of soil moisture in Italy

    Directory of Open Access Journals (Sweden)

    G. Macelloni

    2003-01-01

    Full Text Available Within the framework of the MAP and RAPHAEL projects, airborne experimental campaigns were carried out by the IFAC group in 1999 and 2000, using a multifrequency microwave radiometer at L, C and X bands (1.4, 6.8 and 10 GHz. The aim of the experiments was to collect soil moisture and vegetation biomass information on agricultural areas to give reliable inputs to the hydrological models. It is well known that microwave emission from soil, mainly at L-band (1.4 GHz, is very well correlated to its moisture content. Two experimental areas in Italy were selected for this project: one was the Toce Valley, Domodossola, in 1999, and the other, the agricultural area of Cerbaia, close to Florence, where flights were performed in 2000. Measurements were carried out on bare soils, corn and wheat fields in different growth stages and on meadows. Ground data of soil moisture (SMC were collected by other research teams involved in the experiments. From the analysis of the data sets, it has been confirmed that L-band is well related to the SMC of a rather deep soil layer, whereas C-band is sensitive to the surface SMC and is more affected by the presence of surface roughness and vegetation, especially at high incidence angles. An algorithm for the retrieval of soil moisture, based on the sensitivity to moisture of the brightness temperature at C-band, has been tested using the collected data set. The results of the algorithm, which is able to correct for the effect of vegetation by means of the polarisation index at X-band, have been compared with soil moisture data measured on the ground. Finally, the sensitivity of emission at different frequencies to the soil moisture profile was investigated. Experimental data sets were interpreted by using the Integral Equation Model (IEM and the outputs of the model were used to train an artificial neural network to reproduce the soil moisture content at different depths. Keywords: microwave radiometry, soil moisture

  3. Calibration technique for the neutron surface moisture measurement system

    International Nuclear Information System (INIS)

    Watson, W.T.; Shreve, D.C.

    1996-01-01

    A technique for calibrating the response of a surface neutron moisture measurement probe to material moisture concentration has been devised. Tests to ensure that the probe will function in the expected in-tank operating environment are also outlined

  4. Moisture dependence of radon transport in concrete : Measurements and modeling

    NARCIS (Netherlands)

    Cozmuta, [No Value; van der Graaf, ER; de Meijer, RJ

    2003-01-01

    The moisture dependence of the radon-release rate of concrete was measured under well controlled conditions. It was found that the radon-release rate almost linearly increases up to moisture contents of 50 to 60%. At 70 to 80% a maximum was found and for higher moisture contents the radon-release

  5. Effects of neutron source type on soil moisture measurement

    Science.gov (United States)

    Irving Goldberg; Norman A. MacGillivray; Robert R. Ziemer

    1967-01-01

    A number of radioisotopes have recently become commercially available as alternatives to radium-225 in moisture gauging devices using alpha-neutron sources for determining soil moisture, for well logging, and for other industrial applications in which hydrogenous materials are measured.

  6. Time domain reflectometry measured moisture content of sewage sludge compost across temperatures.

    Science.gov (United States)

    Cai, Lu; Chen, Tong-Bin; Gao, Ding; Liu, Hong-Tao; Chen, Jun; Zheng, Guo-Di

    2013-01-01

    Time domain reflectometry (TDR) is a prospective measurement technology for moisture content of sewage sludge composting material; however, a significant dependence upon temperature has been observed. The objective of this study was to assess the impacts of temperature upon moisture content measurement and determine if TDR could be used to monitor moisture content in sewage sludge compost across a range of temperatures. We also investigated the combined effects of temperature and conductivity on moisture content measurement. The results revealed that the moisture content of composting material could be determined by TDR using coated probes, even when the measured material had a moisture content of 0.581 cm(3)cm(-3), temperature of 70°C and conductivity of 4.32 mS cm(-1). TDR probes were calibrated as a function of dielectric properties that included temperature effects. When the bulk temperature varied from 20°C to 70°C, composting material with 0.10-0.70 cm(3)cm(-3) moisture content could be measured by TDR using coated probes, and calibrations based on different temperatures minimized the errors. Copyright © 2012. Published by Elsevier Ltd.

  7. Technical report on levels of electromagnetic fields created by Linky meters. Part 1: laboratory measurements; Part 2: laboratory additional measurements; Part 3: field measurements

    International Nuclear Information System (INIS)

    2016-05-01

    The first part of this study reports measurements of electromagnetic radiations induced by remote-metering reading devices present in new power meters and using the Power-Line Communication (PLC or, in French, CPL) technology, such as the Linky meter. After a recall of legislation regarding exposure to electromagnetic waves, this first part present the two tested meters (Linky of first and third generation, G1 and G3), the performed tests, measurements devices and method. It more precisely reports investigations performed on these both meters, and a comparison with other home appliances. The second part reports additional measurements performed with both meters according to the same methodology, but with the use of a new electric field probe which allows more precise measurements. Maximum electric and magnetic fields have been measured. The third part reports field measurements performed with the same methodology but in dwellings equipped with Linky meters of first generation (G1). Exposure levels have been measured at the vicinity of meters and in other parts of the dwelling

  8. A Unilateral Nuclear Magnetic Resonance Sensor for Nondestructive Wood Moisture Measurements

    Directory of Open Access Journals (Sweden)

    YU Deng-jie

    2017-12-01

    Full Text Available An unilateral nuclear magnetic resonance (UMR sensor was designed to measure wood moisture nondestructively. The sensor consisted of a unilateral magnet, an anti-eddy current module, a radiofrequency (RF coil and an impedance matching and tuning circuit. The sensor produced a static magnetic field of 71.1 mT (resonant frequency:3.027 MHz in a 50 mm×50 mm plane locating 75 mm above the sensor's surface. Preliminary nondestructive measurement of wood moisture was carried out with the sensor. The moisture distribution in the radical direction of a cylindrical wood sample was scanned. Variations in transverse relaxation time (T2 from the bark to core were obtained. Evaporation of moisture during wood drying was also measured with the UMR sensor. Experimental results showed that:the peak of long T2 component in the T2 spectrum moved to left and the peak integral area decreased gradually during drying. The integral area was proportional to the moisture content of the sample. The work presents a portable UMR device for wood research which may potentially be used for nondestructive moisture measurement on living trees in situ.

  9. Construction, in vitro and in vivo evaluation of an in-house conductance meter for measurement of skin hydration.

    Science.gov (United States)

    Hamed, Saja H; Altrabsheh, Bilal; Assa'd, Tareq; Jaradat, Said; Alshra'ah, Mohammad; Aljamal, Abdulfattah; Alkhatib, Hatim S; Almalty, Abdul-Majeed

    2012-12-01

    Different probes are used in dermato-cosmetic research to measure the electrical properties of the skin. The principle governing the choice of the geometry and material of the measuring probe is not well defined in the literature and some device's measuring principles are not accessible for the scientific community. The purpose of this work was to develop a simple inexpensive conductance meter for the objective in vivo evaluation of skin hydration. The conductance meter probe was designed using the basic equation governing wave propagation along Transverse Electromagnetic transmission lines. It consisted of two concentric copper circular electrodes printed on FR4 dielectric material. The performance of the probe was validated by evaluating its measurement depth, its ability to monitor in vitro water sorption-desorption and in vivo skin hydration effect in comparison to that of the Corneometer CM 825. The measurement depth of the probe, 15 μm, was comparable to that of CM 825. The in vitro readings of the probe correlated strongly with the amount of water adsorbed on filter paper. Skin hydration after application of a moisturizer was monitored effectively by the new probe with good correlation to the results of CM 825. In conclusion, a simple probe for evaluating skin hydration was made from off-the-shelf materials and its performance was validated in comparison to a commercially available probe. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Surface moisture measurement system hardware acceptance test report

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, G.A., Westinghouse Hanford

    1996-05-28

    This document summarizes the results of the hardware acceptance test for the Surface Moisture Measurement System (SMMS). This test verified that the mechanical and electrical features of the SMMS functioned as designed and that the unit is ready for field service. The bulk of hardware testing was performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. The SMMS was developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks.

  11. Measurement of moisture depth distribution in composite materials using positron lifetime technique

    International Nuclear Information System (INIS)

    Singh, J.J.; Holt, W.H.; Mock, W. Jr.; Mall, G.H.

    1980-01-01

    Fiber-reinforced resin matrix composites reportedly suffer significant degradation in their mechanical properties when exposed to hot, moist, environments for extended periods. Moisture weakens the fiber matrix bond as well as the matrix shear strength. An important factor in determining the extent of degradation is the depth distribution of moisture in the resin matrix. Despite the importance of measuring moisture distribution and its effects on composite material properties, not enough data are available on suitable nondestructive techniques for detecting and measuring moisture diffusion in organic composite materials. This paper addresses itself to the problem of measuring the moisture content of such materials, with special emphasis on its depth distribution, using positron lifetime technique

  12. Eddy-current flow rate meter for measuring sodium flow rates

    International Nuclear Information System (INIS)

    Knaak, J.

    1976-01-01

    For safety reasons flow rate meters for monitoring coolant flow rates are inserted in the core of sodium-cooled fast breeder reactors. These are so-called eddy-current flow rate meters which can be mounted directly above the fuel elements. In the present contribution the principle of measurement, the mechanical construction and the circuit design of the flow rate measuring device are described. Special problems and their solution on developing the measuring system are pointed out. Finally, results of measurement and experience with the apparatus in several experiments are reported, where also further possibilities of application were tested. (orig./TK) [de

  13. Correlation between near infrared spectroscopy and electrical techniques in measuring skin moisture content

    International Nuclear Information System (INIS)

    Mohamad, M; Sabbri, A R M; Jafri, M Z Mat; Omar, A F

    2014-01-01

    Near infrared (NIR) spectroscopy technique serves as an important tool for the measurement of moisture content of skin owing to the advantages it has over the other techniques. The purpose of the study is to develop a correlation between NIR spectrometer with electrical conventional techniques for skin moisture measurement. A non-invasive measurement of moisture content of skin was performed on different part of human face and hand under control environment (temperature 21 ± 1 °C, relative humidity 45 ± 5 %). Ten healthy volunteers age between 21-25 (male and female) participated in this study. The moisture content of skin was measured using DermaLab ® USB Moisture Module, Scalar Moisture Checker and NIR spectroscopy (NIRQuest). Higher correlation was observed between NIRQuest and Dermalab moisture probe with a coefficient of determination (R 2 ) above 70 % for all the subjects. However, the value of R 2 between NIRQuest and Moisture Checker was observed to be lower with the R 2 values ranges from 51.6 to 94.4 %. The correlation of NIR spectroscopy technique successfully developed for measuring moisture content of the skin. The analysis of this correlation can help to establish novel instruments based on an optical system in clinical used especially in the dermatology field

  14. Using a terrestrial laser scanner to measure spatiotemporal surface moisture dynamics

    Science.gov (United States)

    Smit, Y.; Donker, J.; Ruessink, G.

    2017-12-01

    A terrestrial laser scanner (TLS) is an active remote sensing technique that utilizes the round trip time of an emitted laser beam to provide the range between the laser scanner and the backscattering object. It is routinely used for topographic mapping, forest measurements or 3D city models since it derives useful object representations by means of a dense three-dimensional (3D) point cloud. Here, we present a novel application using the returned intensity of the emitted beam to detect surface moisture with the RIEGL VZ-400. Because this TLS operates at a wavelength near a water absorption band (1550 nm), reflectance is an accurate parameter to measure surface moisture over its full range. Five days of intensive laser scanning were performed on a Dutch beach to illustrate the applicability of the TLS. Concurrent gravimetric surface moisture samples were collected to calibrate the relation between reflectance and surface moisture. Results reveal the reflectance output is a robust parameter to measure surface moisture from the thin upper layer over its full range from 0% to 25%. The obtained calibration curve of the presented TLS, describing the relationship between reflectance and surface moisture, has a root-mean-square error of 2.7% and a correlation coefficient squared of 0.85. This relation holds to about 60 m from the TLS. Within this distance the TLS typically produces O(10^6-10^7) data points, which we averaged into surface moisture maps with a 1 x 1 m resolution. This grid size largely removes small moisture disturbances induced by, for example, footprints or tire tracks, while retaining larger scale trends. Concluding, TLS (RIEGL-VZ 400) is a highly suited technique to accurately and robustly measure spatiotemporal surface moisture variations on a coastal beach with high spatial ( 1 x 1 m) and temporal ( 15-30min.) resolution.

  15. 40 CFR 92.117 - Gas meter or flow instrumentation calibration, particulate measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... ENGINES Test Procedures § 92.117 Gas meter or flow instrumentation calibration, particulate measurement. (a) Sampling for particulate emissions requires the use of gas meters or flow instrumentation to...

  16. Moisture measurements in iron ores, in freight cars, through nuclear techniques

    International Nuclear Information System (INIS)

    Castagnet, A.C.; Said, M.; Duarte, U.

    1975-01-01

    The possibility and the advantages of using a nuclear technique for measuring on the spot (in the freight cars) and the moisture content of iron ores are described. The measurements included the determination of the volumetric moisture content and the density. From this values, the moisture content in percentage by weight was calculated. Nuclear Chicago d/M Combination Density-Moisture Probe with a 5 mCi Ra/Be source, and a digital portable scaler, were used. The investigated techniques give good results when the measurements are made directly on the ore surface, and has economical advantages over the gravimetric method by sampling. The probable reasons for both, the aleatory scattering of points and the lack of linear correlation between the values of both methods, when the nuclear measurement is made across the car walls are analized

  17. Soil moisture in sessile oak forest gaps

    Science.gov (United States)

    Zagyvainé Kiss, Katalin Anita; Vastag, Viktor; Gribovszki, Zoltán; Kalicz, Péter

    2015-04-01

    By social demands are being promoted the aspects of the natural forest management. In forestry the concept of continuous forest has been an accepted principle also in Hungary since the last decades. The first step from even-aged stand to continuous forest can be the forest regeneration based on gap cutting, so small openings are formed in a forest due to forestry interventions. This new stand structure modifies the hydrological conditions for the regrowth. Without canopy and due to the decreasing amounts of forest litter the interception is less significant so higher amount of precipitation reaching the soil. This research focuses on soil moisture patterns caused by gaps. The spatio-temporal variability of soil water content is measured in gaps and in surrounding sessile oak (Quercus petraea) forest stand. Soil moisture was determined with manual soil moisture meter which use Time-Domain Reflectometry (TDR) technology. The three different sizes gaps (G1: 10m, G2: 20m, G3: 30m) was opened next to Sopron on the Dalos Hill in Hungary. First, it was determined that there is difference in soil moisture between forest stand and gaps. Second, it was defined that how the gap size influences the soil moisture content. To explore the short term variability of soil moisture, two 24-hour (in growing season) and a 48-hour (in dormant season) field campaign were also performed in case of the medium-sized G2 gap along two/four transects. Subdaily changes of soil moisture were performed. The measured soil moisture pattern was compared with the radiation pattern. It was found that the non-illuminated areas were wetter and in the dormant season the subdaily changes cease. According to our measurements, in the gap there is more available water than under the forest stand due to the less evaporation and interception loss. Acknowledgements: The research was supported by TÁMOP-4.2.2.A-11/1/KONV-2012-0004 and AGRARKLIMA.2 VKSZ_12-1-2013-0034.

  18. Moisture Distribution in Broccoli: Measurements by MRI Hot Air Drying Experiments

    NARCIS (Netherlands)

    Jin, X.; Sman, van der R.G.M.; Gerkema, E.; Vergeldt, F.J.; As, van H.; Boxtel, van A.J.B.

    2011-01-01

    ABSTRACT The internal moisture distribution that arise in food products during drying, is a key factor for the retention of quality attributes. To reveal the course of moisture content in a product, internal moisture profiles in broccoli florets are measured by MRI imaging during drying experiments

  19. Moisture distribution in broccoli: measurements by MRI hot air drying experiments

    NARCIS (Netherlands)

    Jin, X.; Sman, van der R.G.M.; Gerkema, E.; Vergeldt, F.J.; As, van H.; Boxtel, van A.J.B.

    2011-01-01

    The internal moisture distribution that arise in food products during drying, is a key factor for the retention of quality attributes. To reveal the course of moisture content in a product, internal moisture profiles in broccoli florets are measured by MRI imaging during drying experiments with

  20. Adjustments of microwave-based measurements on coal moisture using natural radioactivity techniques

    Energy Technology Data Exchange (ETDEWEB)

    Prieto-Fernandez, I.; Luengo-Garcia, J.C.; Alonso-Hidalgo, M.; Folgueras-Diaz, B. [University of Oviedo, Gijon (Spain)

    2006-01-07

    The use of nonconventional on-line measurements of moisture and ash content in coal is presented. The background research is briefly reviewed. The possibilities of adjusting microwave-based moisture measurements using natural radioactive techniques, and vice versa, are proposed. The results obtained from the simultaneous analysis of moisture and ash content as well as the correlation improvements are shown.

  1. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    Science.gov (United States)

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  2. Surface moisture measurement system hardware acceptance test procedure

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1996-01-01

    The purpose of this acceptance test procedure is to verify that the mechanical and electrical features of the Surface Moisture Measurement System are operating as designed and that the unit is ready for field service. This procedure will be used in conjunction with a software acceptance test procedure, which addresses testing of software and electrical features not addressed in this document. Hardware testing will be performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  3. Effect of Doppler flow meter position on discharge measurement in surcharged manholes.

    Science.gov (United States)

    Yang, Haoming; Zhu, David Z; Liu, Yanchen

    2018-02-01

    Determining the proper installation location of flow meters is important for accurate measurement of discharge in sewer systems. In this study, flow field and flow regimes in two types of manholes under surcharged flow were investigated using a commercial computational fluid dynamics (CFD) code. The error in measuring the flow discharge using a Doppler flow meter (based on the velocity in a Doppler beam) was then estimated. The values of the corrective coefficient were obtained for the Doppler flow meter at different locations under various conditions. Suggestions for selecting installation positions are provided.

  4. Investigation of a Plugging Meter for Measuring Impurity Content in Liquid Sodium (I)

    International Nuclear Information System (INIS)

    Choi, Jong Hyeun; Kim, Jong Man; Choi, Byoung Hae; Jeong, Ji Young; Lee, Yong Bum

    2010-01-01

    In a Sodium-cooled Fast Reactor (SFR), liquid sodium is subject to the formation of impurities by its high chemical reactivity with so many elements and common compounds used in nuclear reactor construction materials. The impurities are mainly in the form of hydrides, oxides, metallic compounds, metallic and carbon particles, which originate primarily from steam generator corrosion, moisture from system component surface, and leakage of air into the system. These are finally deposited in the form of the crystallization of sodium hydride (NaH) or sodium oxide (Na 2 O) at the cold points of the circuit, which may lead to the clogging of the narrowed sections or may damage the pump. Therefore, the sodium must be purified and analyzed in order to prevent from the detrimental influence. The analysis of hydrogen and oxygen is very important. There are many chemical methods for analyzing the impurities, but these methods are time-consuming, troublesome and contamination of samples from air and containers, that is the reason why the countries develop the instruments of impurity on-line measurement. The plugging meter is one of the most important on-line measuring instruments and it is a reliable instrument which has been widely used on sodium loops

  5. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  6. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  7. Seven methods to measure ground moisture

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The correct irrigation methods are of great importance to the deciduous fruit grower. The article discusses seven methods for the measuring of ground humidity. These methods are based on gravimetry, electric resistance, gamma attenuation, neutron humidity measurement, tensiometers and a study of the correlation between ground humidity and water evaporation. At this stage, the last technique is regarded as the most practicle method. Neutron moisture gages might be used if adhered to the regulations of NUCOR

  8. Development of an instrument for measuring moisture deep into solid materials

    International Nuclear Information System (INIS)

    Westin, R.; Walletun, H.

    1993-01-01

    It is of value in some applications to be able to detect humidity rather deep into a solid material, for example when determining the moisture content in the frame of buildings, in insulation or in biofuels. Common to these measurement problems is that it is difficult to measure moisture in the bulk of a solid, in contrast to the surface layers. In this report is described the principle and the functioning of an instrument to measure moisture at larger depths than other instruments that are available today. It is intended for use primarily on solid materials, not on gases or liquids. Field experience is also reported here. The principle of the measuring technique is nuclear: we have utilized the ability of hydrogen atoms to moderate (or brake) high energy neutrons. If there is hydrogen in the sample, fast neutrons will interact with the hydrogen atoms and one may detect and count low energy, so called thermal neutrons. The intensity of the slow neutron flux is proportional to the water content, if one assumes that hydrogen atoms are water, i.e. moisture

  9. Index of Refraction Measurements Using a Laser Distance Meter

    Science.gov (United States)

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  10. Measuring Soil Moisture in Skeletal Soils Using a COSMOS Rover

    Science.gov (United States)

    Medina, C.; Neely, H.; Desilets, D.; Mohanty, B.; Moore, G. W.

    2017-12-01

    The presence of coarse fragments directly influences the volumetric water content of the soil. Current surface soil moisture sensors often do not account for the presence of coarse fragments, and little research has been done to calibrate these sensors under such conditions. The cosmic-ray soil moisture observation system (COSMOS) rover is a passive, non-invasive surface soil moisture sensor with a footprint greater than 100 m. Despite its potential, the COSMOS rover has yet to be validated in skeletal soils. The goal of this study was to validate measurements of surface soil moisture as taken by a COSMOS rover on a Texas skeletal soil. Data was collected for two soils, a Marfla clay loam and Chinati-Boracho-Berrend association, in West Texas. Three levels of data were collected: 1) COSMOS surveys at three different soil moistures, 2) electrical conductivity surveys within those COSMOS surveys, and 3) ground-truth measurements. Surveys with the COSMOS rover covered an 8000-h area and were taken both after large rain events (>2") and a long dry period. Within the COSMOS surveys, the EM38-MK2 was used to estimate the spatial distribution of coarse fragments in the soil around two COSMOS points. Ground truth measurements included coarse fragment mass and volume, bulk density, and water content at 3 locations within each EM38 survey. Ground-truth measurements were weighted using EM38 data, and COSMOS measurements were validated by their distance from the samples. There was a decrease in water content as the percent volume of coarse fragment increased. COSMOS estimations responded to both changes in coarse fragment percent volume and the ground-truth volumetric water content. Further research will focus on creating digital soil maps using landform data and water content estimations from the COSMOS rover.

  11. Instrument for measuring moisture in wood chips

    Energy Technology Data Exchange (ETDEWEB)

    Werme, L

    1980-06-01

    A method to determine the moisture content in wood chips, in batch and on-line, has been investigated. The method can be used for frozen and non frozen chips. Samples of wood chips are thawn and dryed with microwaves. During the drying the sample is weighed continously and the rate of drying is measured. The sample is dried t 10 percent moisture content. The result is extrapolated to the drying rate zero. The acccuracy at the method is 1.6 to 1.7 percent for both frozen and non frozen chips. The accuracy of the method is considered acceptable, but sofisticated sampling equipment is necessary. This makes the method too complex to make the instrument marketable.

  12. The error analysis of coke moisture measured by neutron moisture gauge

    International Nuclear Information System (INIS)

    Tian Huixing

    1995-01-01

    The error of coke moisture measured by neutron method in the iron and steel industry is analyzed. The errors are caused by inaccurate sampling location in the calibration procedure on site. By comparison, the instrument error and the statistical fluctuation error are smaller. So the sampling proportion should be increased as large as possible in the calibration procedure on site, and a satisfied calibration effect can be obtained on a suitable size hopper

  13. Optimal metering plan for measurement and verification on a lighting case study

    International Nuclear Information System (INIS)

    Ye, Xianming; Xia, Xiaohua

    2016-01-01

    M&V (Measurement and Verification) has become an indispensable process in various incentive EEDSM (energy efficiency and demand side management) programmes to accurately and reliably measure and verify the project performance in terms of energy and/or cost savings. Due to the uncertain nature of the unmeasurable savings, there is an inherent trade-off between the M&V accuracy and M&V cost. In order to achieve the required M&V accuracy cost-effectively, we propose a combined spatial and longitudinal MCM (metering cost minimisation) model to assist the design of optimal M&V metering plans, which minimises the metering cost whilst satisfying the required measurement and sampling accuracy of M&V. The objective function of the proposed MCM model is the M&V metering cost that covers the procurement, installation and maintenance of the metering system whereas the M&V accuracy requirements are formulated as the constraints. Optimal solutions to the proposed MCM model offer useful information in designing the optimal M&V metering plan. The advantages of the proposed MCM model are demonstrated by a case study of an EE lighting retrofit project and the model is widely applicable to other M&V lighting projects with different population sizes and sampling accuracy requirements. - Highlights: • A combined spatial and longitudinal optimisation model is proposed to reduce M&V cost. • The combined optimisation model handles M&V sampling uncertainty cost-effectively. • The model exhibits a better performance than the separate spatial or longitudinal models. • The required 90/10 criterion sampling accuracy is satisfied for each M&V report.

  14. Measuring methods in power metering 2013; Elektrizitaetsmesstechnik 2013

    Energy Technology Data Exchange (ETDEWEB)

    Kahmann, Martin; Zayer, Peter (eds.)

    2012-07-01

    The book addresses technical and economic issues of power metering, data communication and data processing. Smart metering is the key issue discussed in all 14 contributions: 1. The perspective of Smart Metering in Europe through 2020; 2. Introduction of Smart Metering in Austria; 3. Metering after the amended EnWG 2011; 4. The FNN project ''MessSystem 2020''; 5. Technological requirements of Smart Grid and Smart Market; 6. DIN Spec 33440 ''Ergonomic Aspects of Smart Grids and Electromobility''; 7. Load management as a key element of energy transition; 8. Added value in Smart Metering as a result of Smart Home applications, 9. The main cost factors of the new metering systems; 10. BSI protection profile: Smart Meter Gateway certification; 11. The influence of new boundary conditions in metering on intercompany processes; 12. Reliable time allotment via internet; 13. Recommendations of the EEG Clearing Authority on metering problems; 14. Outline quality management manual for state-authorized test services for electric power, gas, water, and heat. [German] Dieses Buch richtet seinen Blick sowohl auf technische wie auch auf energiewirtschaftliche Themen rund um das Thema Mess- und Zaehltechnik sowie die inzwischen immer bedeutsamer werdende zugehoerige Datenkommunikations- und Datenverarbeitungstechnik. Eine zunehmende Betrachtung des Smart Metering als einen Teilaspekt des grossen Themas Smart Grid bildet die gemeinsame Klammer um die Beitraege. Die Themen der 14 Beitraege sind: 1. Perspektive Smart Metering in Europa bis 2020; 2. Smart-Meter-Einfuehrung in Oesterreich; 3. Das Messwesen nach der EnWG-Novelle 2011; 4. Das FNN-Projekt ''MessSystem 2020''; 5. Anforderungen durch Smart Grid und Smart Market an die intelligente Messtechnik; 6. DIN Spec 33440 ''Ergonomie-Aspekte zu Smart Grid und Elektromobilitaet''; 7. Lastverschiebung als Baustein der Energiewende; 8. Mehrwerte beim Smart

  15. Continuous moisture measurement in metallurgical coke with automatic charge correction

    International Nuclear Information System (INIS)

    Watzke, H.; Mehlhose, D.

    1981-01-01

    A process control system has been developed for automatic batching of the coke amount necessary for metallurgical processes taking into account the moisture content. The measurement is performed with a neutron moisture gage consisting of an Am-Be neutron source and a BF 3 counter. The output information of the counter is used for computer-controlled batching

  16. System design description for surface moisture measurement system (SMMS)

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F.

    1996-09-23

    The SMMS has been developed to measure moisture in the top few centimeters of tank waste. The SMMS development was initiated by the preliminary findings of SAR-033, and does not necessarily fulfill any established DQO. After the SAR-033 is released, if no significant changes are made, moisture measurements in the organic waste tanks will rapidly become a DQO. The SMMS was designed to be installed in any 4 inch or larger riser, and to allow maximum adjustability for riser lengths, and is used to deploy a sensor package on the waste surface within a 6 foot radius about the azimuth. The first sensor package will be a neutron probe.

  17. Measuring seasonal variations of moisture in a landfill with the partitioning gas tracer test

    International Nuclear Information System (INIS)

    Han, Byunghyun; Jafarpour, Behnam; Gallagher, Victoria N.; Imhoff, Paul T.; Chiu, Pei C.; Fluman, Daniel A.

    2006-01-01

    Seven pilot-scale partitioning gas tracer tests (PGTTs) were conducted to assess the accuracy and reproducibility of this method for measuring water in municipal solid waste landfills. Tests were conducted in the same location over a 12-month period, and measured moisture conditions ranged from possible dry waste to refuse with a moisture content of 24.7%. The final moisture content of 24.7% was in reasonable agreement with gravimetric measurements of excavated refuse, where the moisture content was 26.5 ± 6.0CI%. Laboratory tests were used to assess the utility of the PGTT for measuring water in small pores, water sorbed to solid surfaces, and the influence of dry waste on PGTTs. These experiments indicated that when refuse surfaces are not completely solvated with water, PGTTs may produce misleading results (negative estimates) of water saturation and moisture content

  18. Measurement of microchannel fluidic resistance with a standard voltage meter

    International Nuclear Information System (INIS)

    Godwin, Leah A.; Deal, Kennon S.; Hoepfner, Lauren D.; Jackson, Louis A.; Easley, Christopher J.

    2013-01-01

    Highlights: ► Standard voltage meter used to measure fluidic resistance. ► Manual measurement takes a few seconds, akin to electrical resistance measurements. ► Measurement error is reduced compared to other approaches. ► Amenable to dynamic measurement of fluidic resistance. - Abstract: A simplified method for measuring the fluidic resistance (R fluidic ) of microfluidic channels is presented, in which the electrical resistance (R elec ) of a channel filled with a conductivity standard solution can be measured and directly correlated to R fluidic using a simple equation. Although a slight correction factor could be applied in this system to improve accuracy, results showed that a standard voltage meter could be used without calibration to determine R fluidic to within 12% error. Results accurate to within 2% were obtained when a geometric correction factor was applied using these particular channels. When compared to standard flow rate measurements, such as meniscus tracking in outlet tubing, this approach provided a more straightforward alternative and resulted in lower measurement error. The method was validated using 9 different fluidic resistance values (from ∼40 to 600 kPa s mm −3 ) and over 30 separately fabricated microfluidic devices. Furthermore, since the method is analogous to resistance measurements with a voltage meter in electrical circuits, dynamic R fluidic measurements were possible in more complex microfluidic designs. Microchannel R elec was shown to dynamically mimic pressure waveforms applied to a membrane in a variable microfluidic resistor. The variable resistor was then used to dynamically control aqueous-in-oil droplet sizes and spacing, providing a unique and convenient control system for droplet-generating devices. This conductivity-based method for fluidic resistance measurement is thus a useful tool for static or real-time characterization of microfluidic systems.

  19. Apparatus for measuring moisture in moving bulk material using a lithium-7 radiation source

    International Nuclear Information System (INIS)

    Ashe, J.B.

    1976-01-01

    A nucleonic device is described for measuring the moisture content of bulk materials using a radioisotopic fast-neutron source such as lithium-7 admixed with an alpha-particle emitter such as americium-241 as a means of minimizing the thickness of the layer of bulk material required proximate to the moisture sensor for a neutron-reflection moisture gauge for proper operation of said gauge. Minimization of the required thickness of the bulk material permits use of a neutron-reflection moisture gauge for measurements of bulk materials on lightly-loaded belts and other types of conveyors where measurements have previously been impracticable

  20. Comparison of neutron scattering, gravimetric and tensiometric methods for measuring soil water content in the field

    International Nuclear Information System (INIS)

    Jat, R.L.; Das, D.K.; Naskar, G.C.

    1975-01-01

    Water content of a sandy clay loam soil was measured by neutron scattering, gravimetric and tensiometric methods. Tensiometric measurement based on laboratory moisture retention curve gave comparatively higher moisture content than those obtained by other methods. No significant differences were observed among neutron meter, gravimetric and tensiometric measurement based on field calibration curve. Though for irrigation purposes all the methods can be used equally, use of tensiometric method with field calibration curve is suggested for easy and more accurate soil water content measurement where neutron meter is not available. (author)

  1. Development and evaluation of a meter for measuring return line fluid flow rates during drilling

    Energy Technology Data Exchange (ETDEWEB)

    Loeppke, G.E.; Schafer, D.M.; Glowka, D.A.; Scott, D.D.; Wernig, M.D. (Sandia National Labs., Albuquerque, NM (United States)); Wright, E.K. (Ktech Corp., Albuquerque, NM (United States))

    1992-06-01

    The most costly problem routinely encountered in geothermal drilling is lost circulation, which occurs when drilling fluid is lost to the formation rather than circulating back to the surface. The successful and economical treatment of lost circulation requires the accurate measurement of drilling fluid flow rate both into and out of the well. This report documents the development of a meter for measuring drilling fluid outflow rates in the return line of a drilling rig. The meter employs a rolling counterbalanced float that rides on the surface of the fluid in the return line. The angle of the float pivot arm is sensed with a pendulum potentiometer, and the height of the float is calculated from this measurement. The float height is closely related to the fluid height and, therefore, the flow rate in the line. The prototype rolling float meter was extensively tested under laboratory conditions in the Wellbore Hydraulics Flow Facility; results from these tests were used in the design of the field prototype rolling float meter. The field prototype meter was tested under actual drilling conditions in August and September 1991 at the Long Valley Exploratory Well near Mammoth Lakes, Ca. In addition, the performance of several other commercially available inflow and outflow meters was evaluated in the field. The tested inflow meters included conventional pump stroke counters, rotary pump speed counters, magnetic flowmeters, and an ultrasonic Doppler flowmeter. On the return flow line, a standard paddlemeter, an acoustic level meter, and the prototype rolling float meter were evaluated for measuring drilling fluid outflow rates.

  2. The Utility of Using a Near-Infrared (NIR) Camera to Measure Beach Surface Moisture

    Science.gov (United States)

    Nelson, S.; Schmutz, P. P.

    2017-12-01

    Surface moisture content is an important factor that must be considered when studying aeolian sediment transport in a beach environment. A few different instruments and procedures are available for measuring surface moisture content (i.e. moisture probes, LiDAR, and gravimetric moisture data from surface scrapings); however, these methods can be inaccurate, costly, and inapplicable, particularly in the field. Near-infrared (NIR) spectral band imagery is another technique used to obtain moisture data. NIR imagery has been predominately used through remote sensing and has yet to be used for ground-based measurements. Dry sand reflects infrared radiation given off by the sun and wet sand absorbs IR radiation. All things considered, this study assesses the utility of measuring surface moisture content of beach sand with a modified NIR camera. A traditional point and shoot digital camera was internally modified with the placement of a visible light-blocking filter. Images were taken of three different types of beach sand at controlled moisture content values, with sunlight as the source of infrared radiation. A technique was established through trial and error by comparing resultant histogram values using Adobe Photoshop with the various moisture conditions. The resultant IR absorption histogram values were calibrated to actual gravimetric moisture content from surface scrapings of the samples. Overall, the results illustrate that the NIR spectrum modified camera does not provide the ability to adequately measure beach surface moisture content. However, there were noted differences in IR absorption histogram values among the different sediment types. Sediment with darker quartz mineralogy provided larger variations in histogram values, but the technique is not sensitive enough to accurately represent low moisture percentages, which are of most importance when studying aeolian sediment transport.

  3. Moisture content determination in solid biofuels by dielectric and NIR reflection methods

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Peter Daugbjerg; Morsing, Merete [Department of Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe (TFZ), Schulgasse 18, D-94315 Straubing (Germany); Temmerman, Michael; Rabier, Fabienne [Departement Genie Rural, Chee de Namur 146, B-5030 Gembloux (Belgium)

    2006-11-15

    One near infrared (NIR) reflectance and five dielectric moisture meters were tested for their capability of measuring moisture content (MC) in solid biofuels. Ninety-eight samples were tested at up to eight moisture levels covering the MC range from fresh fuel to approximately 10% MC (w.b.). The fuel types ranged from typical solid biofuels such as coniferous and deciduous wood chips over short rotation coppice (SRC) to sunflower seed and olive stones. The most promising calibrations were obtained with the NIR reflection method and two dielectric devices where the sample is placed in a container integrated in the device. The calibration equations developed show that there is a profound influence from both laboratory and fuel type. It is suggested that individual calibrations that are based on the specific fuel types used at the individual heating plant could be applied. (author)

  4. Agreement of Power Measures between Garmin Vector and SRM Cycle Power Meters

    Science.gov (United States)

    Novak, Andrew R.; Dascombe, Benjamin J.

    2016-01-01

    This study aimed to determine if the Garmin Vector (Schaffhausen, Switzerland) power meter produced acceptable measures when compared with the Schoberer Rad Messetechnik (SRM; Julich, Germany) power meter across a range of high-intensity efforts. Twenty-one well-trained cyclists completed power profiles (seven maximal mean efforts between 5 and…

  5. Measurement of log moisture content and density by gamma and neutron backscatter

    International Nuclear Information System (INIS)

    Barry, B.J.

    2002-01-01

    Measurement of the moisture content and green density of wood was investigated using scattering of gamma rays and neutrons. Both of these processes are dependent on density but neutrons are particularly sensitive to the hydrogen content, which changes with moisture content. A material mimicking the green density and moisture content of real wood was successfully used in a laboratory study to establish the feasibility of measuring these within the range found in standing trees. A later field trial indicated that the technique needed more development to take account of the natural variability of real trees. (author). 3 refs., 11 figs., 1 table

  6. Laboratory microwave measurement of the moisture content in seed cotton and ginned cotton fiber

    Science.gov (United States)

    The timely and accurate measurement of cotton fiber moisture content is important, but the measurement is often performed by laborious, time-consuming laboratory oven drying methods. Microwave technology for measuring fiber moisture content directly (not for drying only) offers potential advantages...

  7. Qualifying Elbow Meters for High Pressure Flow Measurements in an Operating Nuclear Power Plant

    International Nuclear Information System (INIS)

    Chan, A.M.; Maynard, K.J.; Ramundi, J.; Wiklung, E.

    2006-01-01

    To support the installation and use of elbow meters to measure the high pressure emergency coolant injection flow in an operating nuclear station, a test program was performed to qualify: (i) the 'hot' tapping procedure for field application and (ii) the use of elbow meters for accurate flow measurements over the full range of station ECI flow conditions. This paper describes the design conditions and major components of a flow loop used for the elbow meter calibrations. Typical test results are presented and discussed. (authors)

  8. Finally It Is Possible To Measure Area-Average Soil Moisture!

    Science.gov (United States)

    Shuttleworth, W. J.; Zreda, M. G.; Zeng, X.; Zweck, C.; Franz, T. E.; Rosolem, R.

    2011-12-01

    When a hitherto impossible measurement becomes possible, there are transformational changes in understanding. Measuring soil moisture using cosmic rays sounds like 1950s science fiction. But the non-invasive measurement of soil moisture at a horizontal scale of ~700m and depths of 15-70 cm is now feasible, by counting cosmic-ray neutrons that are generated within soil, moderated mainly by the hydrogen atoms, and emitted back to the atmosphere. The number of neutrons counted is sensitive to water content changes, only weakly sensitive to soil chemistry, and their intensity is inversely correlated with the hydrogen (i.e., water) content of the soil. Neither the basis of this measurement method nor the sensor technology used is new, they have been around for decades. However, the systematic understanding of cosmic-ray interactions at the ground-atmosphere interface and resulting knowledge of the source "footprint" of above ground neutron detectors and recognition of their limited of sensitivity to soil type in selected neutron energy bands is new, as is the low power electronics used for remote signal conditioning, counting and data capture. The measurement with a portable neutron detector placed above the ground takes minutes to hours, permitting high-resolution, long-term monitoring of undisturbed soil moisture. The large footprint makes the method suitable for weather and short-term climate forecast initialization and satellite validation, while the measurement depth makes the probe ideal for studying plant/soil/atmosphere interactions. Inclusion of a second detector that is sensitive to neutrons with lower energy shows promise as a means for detecting snow cover. This talk briefly overviews evidence that soil moisture status can potentially influence weather and seasonal climate and describe the COsmic-ray Soil Moisture Observing System (COSMOS), which observing program will install initially a network of 50 probes (to provide a proof of concept) and subsequently

  9. A transit-time flow meter for measuring milliliter per minute liquid flow

    DEFF Research Database (Denmark)

    Yang, Canqian; Kymmel, Mogens; Søeberg, Henrik

    1988-01-01

    A transit-time flow meter, using periodic temperature fluctuations as tracers, has been developed for measuring liquid flow as small as 0.1 ml/min in microchannels. By injecting square waves of heat into the liquid flow upstream with a tiny resistance wire heater, periodic temperature fluctuation....... This flow meter will be used to measure and control the small liquid flow in microchannels in flow injection analysis. Review of Scientific Instruments is copyrighted by The American Institute of Physics....... are generated downstream. The fundamental frequency phase shift of the temperature signal with respect to the square wave is found to be a linear function of the reciprocal mean velocity of the fluid. The transit-time principle enables the flow meter to have high accuracy, better than 0.2%, and good linearity...

  10. Non-destructive radio-frequency and microwave measurement of moisture content in agricultural commodities

    International Nuclear Information System (INIS)

    Nelson, S.O.

    1994-01-01

    The importance of moisture content in agricultural commodities, the usefulness of the dielectric properties of such products for sensing moisture content by radiofrequency and microwave measurements, and factors affecting these properties are briefly discussed. Recent developments in the understanding of principles for online moisture sensing and the sensing of individual kernel, seed, nut and fruit moisture contents by radiofrequency and microwave techniques are reviewed. A brief discussion is included on aspects of practical application

  11. Moisture supply in Danish single-family houses – the influence of occupant behaviour and type of room

    DEFF Research Database (Denmark)

    Møller, Eva B.; Hansen, Ernst Jan de Place

    2017-01-01

    According to ISO 13788, the internal moisture supply in dwellings can be described by humidity classes defined by outdoor temperature, occupancy and ventilation. Hygrothermal measurements in indoor air in 500 Danish single-family houses were made to investigate if this corresponds with reality....... The study focuses on the dependency of number and age of occupants, occupants’ time spent in the house, square meters living space, ventilation habits and type of room. Moisture supply depends on the type of room; bathroom, basement and living room have the highest values. None of the other parameters seems...

  12. Use of Neutron Probe to Quantify the Soil Moisture Flux in Layers of Cultivated Soil by Chickpea

    International Nuclear Information System (INIS)

    El- Gendy, R.W.

    2008-01-01

    This work aims to use the neutron moisture meter and the soil moisture retention curve to quantify the soil moisture flux in the soil profile of Nubarria soil in Egypt at 15, 30, 45, and 60-cm depths during the growth season of Chickpea. This method depends on the use of in situ θ measurements via neutron moisture meter and soil matric suction using model of the soil moisture retention curve at different soil depths, which can be determined in situ. Total hydraulic potential values at the different soil depths were calculated as a function (θ) using the derivative model. The gradient of hydraulic potential at any soil depth can be obtained by detecting of the hydraulic potential within the soil profile. The soil water fluxes at the different soil depths were calculated using In situ measured unsaturated hydraulic conductivity and the gradient of hydraulic potential, which correlated with soil moisture contents as measured by neutron probe. Values of hydraulic potentials after and before irrigation indicate that the direction of soil moisture movement was downward after irrigation and was different before next irrigation. Collecting active roots for water absorption of chickpea were defined from direction of soil water movement from up and down to a certain soil depth was 19 cm depth from the soil surface. Active rooting depth was 53 cm depth, which separates between evapotranspiration and gravity effects The soil water fluxes after and before the next irrigation of chickpea were 1.2453, 0.8613, 0.8197 and 0.6588 cm/hr and 0.0037, - 0.0270,- 0.1341, and 0.2545 cm/hr at 15, 30, 45 and 60 cm depths, respectively. The negative values at 30 and 45 cm depth before the next irrigation indicates there were up ward movement for soil water flux, where finding collecting active roots for water absorption of chickpea at 19 cm depth. Direction of soil water movement, soil water flux, collecting active roots for water absorption and active rooting depth can be determined using

  13. Quantum nondemolition measurement with a nonclassical meter input and an electro-optic enhancement

    DEFF Research Database (Denmark)

    Andersen, Ulrik Lund; Buchler, B.C.; Bachor, H.A.

    2002-01-01

    Optical quantum nondemolition measurements are performed using a beamsplitter with a nonclassical meter input and a electro-optic feedforward loop. The nonclassical meter input is provided by a stable 4.5 dB amplitude squeezed source generated by an optical parametric amplifier. We show...

  14. Two survey meters for measuring low γ-ray dose rates

    International Nuclear Information System (INIS)

    Jones, A.R.

    1979-01-01

    Two low-level survey meters have been developed which have numerical displays. The first is of the light-emitting diode (LED) type. The second is a liquid crystal display (LCD). The design of both instruments is described and results of measurements of performance are presented. They measure γ dose rates from background up to 2 mrad/h (20 μGy/h) for γ-rays in the energy range 0.05-1.25 MeV. They can be used at temperatures between -20 deg C and +50 deg C. Statistical accuracy and battery life both depend upon a number of factors and this dependence is shown. A later section describes the intended application of the survey meters. An appendix describes the circuit adjustments which are necessary and when they must be made. (author)

  15. The study of thickness and density compensation of neutron-measuring moisture system on conveyor belt

    International Nuclear Information System (INIS)

    Jia Wenbao; Su Tongling; Zhang Xiaomin; Xu Zhongfeng

    1999-01-01

    The neutron-measuring transmission moisture system on the conveyer belt is systematically studied. A method of density and thickness compensation has been used to carryout the on-line measurements of the moisture of the unshaped, discontinuous and irregular moving matter. At the same time, the thickness weighed average method is employed to modify the prompt moisture at a fixed time, and to improve the accuracy of measuring the moisture. The experimental data show that the measurement errors are within ±2.5% when the thickness is between 2 cm and 16 cm and the water percentage is between 6% and 16%. The errors can reach 0.2% if thickness weighed average for moving matter lasts for a long time

  16. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  17. Development of a pressure based vortex-shedding meter: measuring unsteady mass-flow in variable density gases

    International Nuclear Information System (INIS)

    Ford, C L; Winroth, M; Alfredsson, P H

    2016-01-01

    An entirely pressure-based vortex-shedding meter has been designed for use in practical time-dependent flows. The meter is capable of measuring mass-flow rate in variable density gases in spite of the fact that fluid temperature is not directly measured. Unlike other vortex meters, a pressure based meter is incredibly robust and may be used in industrial type flows; an environment wholly unsuitable for hot-wires for example. The meter has been tested in a number of static and dynamic flow cases, across a range of mass-flow rates and pressures. The accuracy of the meter is typically better than about 3% in a static flow and resolves the fluctuating mass-flow with an accuracy that is better than or equivalent to a hot-wire method. (paper)

  18. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  19. Radon emanation and soil moisture effects on airborne gamma-ray measurements

    International Nuclear Information System (INIS)

    Grasty, R.L.

    1997-01-01

    A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical and experimental results demonstrate that any estimate of the natural gamma-ray field caused by radium in the ground must take into consideration the radon emanation coefficient of the soil. The radon diffusion coefficient of the soil must also be considered since it depends strongly on soil moisture. This has significant implications for the assessment of outdoor radiation doses using laboratory analyses of soil samples and the use of ground and airborne gamma-ray measurements for radon potential mapping

  20. Digital temperature meter

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S

    1982-01-01

    Digital temperature meter for precise temperature measurements is presented. Its parts such as thermostat, voltage-frequency converter and digital frequency meter are described. Its technical parameters such as temperature range 50degC-700degC, measurement precision 1degC, measurement error +-1degC are given. (A.S.).

  1. Surface moisture measurement system acceptance testing work plan

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1996-01-01

    This work plan addresses testing of the Surface Moisture Measurement System (SMMS) at the Fuels and Materials Examination Facility (FMEF). The purpose of this plan is to define the scope of work, identify organizational responsibilities, describe test control requirements, and provide estimated costs and schedule associated with acceptance testing

  2. Near-surface current meter array measurements of internal gravity waves

    Energy Technology Data Exchange (ETDEWEB)

    Jones, H.B.E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    We have developed various processing algorithms used to estimate the wave forms produced by hydrodynamic Internal Waves. Furthermore, the estimated Internal Waves are used to calculate the Modulation Transfer Function (MTF) which relates the current and strain rate subsurface fields to surface scattering phenomenon imaged by radar. Following a brief discussion of LLNL`s measurement platform (a 10 sensor current meter array) we described the generation of representative current and strain rate space-time images from measured or simulated data. Then, we present how our simulation capability highlighted limitations in estimating strain rate. These limitations spurred the application of beamforming techniques to enhance our estimates, albeit at the expense of collapsing our space-time images to 1-D estimates. Finally, we discuss progress with regard to processing the current meter array data captured during the recent Loch Linnhe field trials.

  3. Heat Loss Measurements in Buildings Utilizing a U-value Meter

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from building envelopes are of great importance in order to reach the Bologna CO2 emission reduction targets. Upgrading of the energy performance...... of buildings is a topic of huge global interest these years. Not only heating in the temperate and arctic regions are important, but also air conditioning and mechanical ventilation in the tropical countries contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish...... the best basis for upgrading the energy performance, it is important to measure the heat losses at different locations on a building facade, in order to optimize the energy performance. The author has invented a U-value meter, enabling measurements of heat transfer coefficients. The meter has been used...

  4. Relationship between moisture content and electrical impedance of carrot slices during drying

    Science.gov (United States)

    Kertész, Ákos; Hlaváčová, Zuzana; Vozáry, Eszter; Staroňová, Lenka

    2015-01-01

    Electrical properties of food materials can give information about the inner structure and physiological state of biological tissues. Generally, the process of drying of fruits and vegetables is followed by weight loss. The aim of this study was to measure the impedance spectra of carrot slices during drying and to correlate impedance parameters to moisture content in different drying periods. Cylindrical slices were cut out from the carrot root along the axis. The slices were dried in a Venticell 111 air oven at 50°C. The weight of the slices was measured with a Denver SI-603 electronic analytical and precision balance. The weighing of the samples was performed every 30 min at the beginning of drying and every 60 min after the process. The moisture content of the samples was calculated on wet basis. The magnitude and phase angle of electrical impedance of the slices were measured with HP 4284A and 4285A precision LCR meters in the frequency range from 30 Hz to 1 MHz and from 75 kHz to 30 MHz, respectively, at voltage 1 V. The impedance measurement was performed after weighting. The change in the magnitude of impedance during drying showed a good correlation with the change in the moisture content.

  5. The pH of the main Brazilian commercial moisturizers and liquid soaps: considerations on the repair of the skin barrier.

    Science.gov (United States)

    Gonçalves, Giovana M; Brianezi, Gabrielli; Miot, Hélio Amante

    2017-01-01

    The pH of the skin is slightly acidic (4.6 to 5.8) which is important for appropriate antibacterial, antifungal, constitution of barrier function, as well as structuring and maturation of the stratum corneum. This study aimed to evaluate the pH of the main commercial moisturizers and liquid soaps in Brazil. Thus, pH of the products was quantified by pH meter in three measurements. A total of 38 moisturizers and six commercial liquid soaps were evaluated. Mean pH of 63% and 50% of the moisturizing and liquid soaps presented results above 5.5, disfavoring repair, function, and synthesis of dermal barrier.

  6. The pH of the main Brazilian commercial moisturizers and liquid soaps: considerations on the repair of the skin barrier*

    Science.gov (United States)

    Gonçalves, Giovana M; Brianezi, Gabrielli; Miot, Hélio Amante

    2017-01-01

    The pH of the skin is slightly acidic (4.6 to 5.8) which is important for appropriate antibacterial, antifungal, constitution of barrier function, as well as structuring and maturation of the stratum corneum. This study aimed to evaluate the pH of the main commercial moisturizers and liquid soaps in Brazil. Thus, pH of the products was quantified by pH meter in three measurements. A total of 38 moisturizers and six commercial liquid soaps were evaluated. Mean pH of 63% and 50% of the moisturizing and liquid soaps presented results above 5.5, disfavoring repair, function, and synthesis of dermal barrier. PMID:29166523

  7. Estimating values for the moisture source load and buffering capacities from indoor climate measurements

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2008-01-01

    The objective of this study is to investigate the potential for estimating values for the total size of human induced moisture source load and the total buffering (moisture storage) capacity of the interior objects with the use of relatively simple measurements and the use of heat, air, and moisture

  8. Advanced Soil Moisture Network Technologies; Developments in Collecting in situ Measurements for Remote Sensing Missions

    Science.gov (United States)

    Moghaddam, M.; Silva, A. R. D.; Akbar, R.; Clewley, D.

    2015-12-01

    The Soil moisture Sensing Controller And oPtimal Estimator (SoilSCAPE) wireless sensor network has been developed to support Calibration and Validation activities (Cal/Val) for large scale soil moisture remote sensing missions (SMAP and AirMOSS). The technology developed here also readily supports small scale hydrological studies by providing sub-kilometer widespread soil moisture observations. An extensive collection of semi-sparse sensor clusters deployed throughout north-central California and southern Arizona provide near real time soil moisture measurements. Such a wireless network architecture, compared to conventional single points measurement profiles, allows for significant and expanded soil moisture sampling. The work presented here aims at discussing and highlighting novel and new technology developments which increase in situ soil moisture measurements' accuracy, reliability, and robustness with reduced data delivery latency. High efficiency and low maintenance custom hardware have been developed and in-field performance has been demonstrated for a period of three years. The SoilSCAPE technology incorporates (a) intelligent sensing to prevent erroneous measurement reporting, (b) on-board short term memory for data redundancy, (c) adaptive scheduling and sampling capabilities to enhance energy efficiency. A rapid streamlined data delivery architecture openly provides distribution of in situ measurements to SMAP and AirMOSS cal/val activities and other interested parties.

  9. Comparison of magnetic field meters used for Elf exposure measurement

    International Nuclear Information System (INIS)

    Magne, I.; Azoulay, A.; Lambrozo, J.; Souques, M.

    2006-01-01

    Objective The question of the biological effects of E.L.F. electromagnetic fields (50/60 Hz) has lead to many experimental and epidemiological works, in occupational exposure and in residential exposure. One of the main difficulties is to integrate the maximum of information about the environmental exposures during the everyday life without limitation to the exposure of the home. The objective of this study is to analyse experimentally the metrology associated with human exposure to 50 Hz magnetic field, in the optic of a study of the French population exposure. Method 4 meters were tested: the E.M.D.E.X. II, currently used in epidemiological studies, the E.M.D.E.X. L.I.T.E., which is more recent, the H.T.300, an Italian meter, and the F.D.3, which is made by Combinova A calibration was performed with an Helmoltz coil. The immunity of these meters to GSM signal was also tested. The influence of the sample rate was evaluated. Results and conclusion The meter chosen for performing the measurements of the exposure study will be selected in function of the following criteria: - easiness of use - precision - low sample rate - memory size and reliability of data stocking - immunity to GSM perturbations. (authors)

  10. Indirect Estimations of Lentil Leaf and Plant N by SPAD Chlorophyll Meter

    Directory of Open Access Journals (Sweden)

    Hossein Zakeri

    2015-01-01

    Full Text Available A Soil Plant Analysis Development (SPAD chlorophyll meter can be used to screen for leaf nitrogen (N concentration in breeding programs. Lentil (Lens culinaris L. cultivars were grown under varied N regimes, SPAD chlorophyll meter readings (SCMR were recorded from the cultivars leaves, and leaf N concentration was measured by combustion. Linear regression and the nonlinear Radial Basis Functions (RBF neural networks models were employed to estimate leaf N concentration (LNC based on the SCMR values. The closest estimates of LNC were obtained from the multivariate models in which the combination of plant age, leaf thickness, and SCMR was employed as the independent variable. In comparison, SCMR as the single independent variable in both models estimated less than 50% of LNC variations. The results showed significant effects of soil moisture and plant age on the association of LNC –SCMR as well as the relationship of LNC with plant N, grain yield, and days to maturity. However, the effect of cultivar on the measured variables was negligible. Although lentil N can be diagnosed by comparing SCMR values of the crop with those from a well-fertilized (N fixing plot, the results did not support using SPAD chlorophyll meter for screening lentil LNC.

  11. Lessons from wet gas flow metering systems using differential measurements devices: Testing and flow modelling results

    Energy Technology Data Exchange (ETDEWEB)

    Cazin, J.; Couput, J.P.; Dudezert, C. et al

    2005-07-01

    A significant number of wet gas meters used for high GVF and very high GVF are based on differential pressure measurements. Recent high pressure tests performed on a variety of different DP devices on different flow loops are presented. Application of existing correlations is discussed for several DP devices including Venturi meters. For Venturi meters, deviations vary from 9% when using the Murdock correlation to less than 3 % with physical based models. The use of DP system in a large domain of conditions (Water Liquid Ratio) especially for liquid estimation will require information on the WLR This obviously raises the question of the gas and liquid flow metering accuracy in wet gas meters and highlight needs to understand AP systems behaviour in wet gas flows (annular / mist / annular mist). As an example, experimental results obtained on the influence of liquid film characteristics on a Venturi meter are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film characterization. The AP measurements indicate that for a same Lockhart Martinelli parameter, the characteristics of the two phase flow have a major influence on the correlation coefficient. A 1D model is defined and the results are compared with the experiments. These results indicate that the flow regime influences the AP measurements and that a better modelling of the flow phenomena is needed even for allocation purposes. Based on that, lessons and way forward in wet gas metering systems improvement for allocation and well metering are discussed and proposed. (author) (tk)

  12. A flow meter for ultrasonically measuring the flow velocity of fluids

    DEFF Research Database (Denmark)

    2015-01-01

    The invention regards a flow meter for ultrasonically measuring the flow velocity of fluids comprising a duct having a flow channel with an internal cross section comprising variation configured to generate at least one acoustic resonance within the flow channel for a specific ultrasonic frequency......, and at least two transducers for generating and sensing ultrasonic pulses, configured to transmit ultrasonic pulses at least at said specific ultrasonic frequency into the flow channel such that the ultrasonic pulses propagate through a fluid flowing in the flow channel, wherein the flow meter is configured...

  13. 40 CFR 86.120-94 - Gas meter or flow instrumentation calibration; particulate, methanol and formaldehyde measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... Procedures § 86.120-94 Gas meter or flow instrumentation calibration; particulate, methanol and formaldehyde measurement. (a) Sampling for particulate, methanol and formaldehyde emissions requires the use of gas meters...

  14. [Development and test of a wheat chlorophyll, nitrogen and water content meter].

    Science.gov (United States)

    Yu, Bo; Sun, Ming; Han, Shu-Qing; Xia, Jin-Wen

    2011-08-01

    A portable meter was developed which can detect chlorophyll, nitrogen and moisture content of wheat leaf simultaneously, and can supply enough data for guiding fertilization and irrigation. This meter is composed of light path and electronic circuit. And this meter uses 660, 940 and 1450 nm LED together with narrow band filters as the active light source. The hardware circuit consists of micro-controller, LED drive circuit, detector, communication circuit, keyboard and LCD circuit. The meter was tested in the field and performed well with good repeatability and accuracy. The relative errors of chlorophyll and nitrogen test were about 10%, relative error for water content was 4%. The coefficients of variation of the three indices were all below 1.5%. All of these prove that the meter can be applied under the field condition to guide the wheat production.

  15. Flow measurement of liquid hydrocarbons with positive displacement meters: the correction for slippage

    International Nuclear Information System (INIS)

    García-Berrocal, Agustín; Montalvo, Cristina; Balbás, Miguel; Blázquez, Juan

    2013-01-01

    In the oil industry, the economical and fiscal impact of the measurements accuracy on the custody transfer operations implies fulfilling strict requirements of legal metrology. In this work, we focus on the positive displacement meters (PD meters) for refined liquid hydrocarbons. The state of the art of the lack of accuracy due to slippage flow in these meters is revised. The slippage flow due to the pressure drop across the device has been calculated analytically by applying the Navier–Stokes equation. No friction with any wall of the slippage channel has been neglected and a more accurate formula than the one found in the literature has been obtained. PD meters are calibrated against a bidirectional prover in order to obtain their meter factor which allows correction of their indications. Instead of the analytical model, an empirical one is proposed to explain the variation of the meter factor of the PD meters with flow rate and temperature for a certain hydrocarbon. The empirical model is based on the historical calibration data, of 9 years on average, of 25 m with four types of refined hydrocarbon. This model has been statistically validated by linear least-squares fitting. By using the model parameters, we can obtain the meter factor corresponding to different conditions of temperature and flow rate from the conditions in which the devices were calibrated. The flow parameter is such that a 10% flow rate variation implies a meter factor variation lower than 0.01%. A rule of thumb value for the temperature parameter is 0.005% per degree Celsius. The model residuals allow surveillance of the device drift and quantifying its contribution to the meter factor uncertainty. The observed drift is 0.09% at 95% confidence level in the analyzed population of meters. (paper)

  16. Recursive Pyramid Algorithm-Based Discrete Wavelet Transform for Reactive Power Measurement in Smart Meters

    Directory of Open Access Journals (Sweden)

    Mahin K. Atiq

    2013-09-01

    Full Text Available Measurement of the active, reactive, and apparent power is one of the most fundamental tasks of smart meters in energy systems. Recently, a number of studies have employed the discrete wavelet transform (DWT for power measurement in smart meters. The most common way to implement DWT is the pyramid algorithm; however, this is not feasible for practical DWT computation because it requires either a log N cascaded filter or O (N word size memory storage for an input signal of the N-point. Both solutions are too expensive for practical applications of smart meters. It is proposed that the recursive pyramid algorithm is more suitable for smart meter implementation because it requires only word size storage of L × Log (N-L, where L is the length of filter. We also investigated the effect of varying different system parameters, such as the sampling rate, dc offset, phase offset, linearity error in current and voltage sensors, analog to digital converter resolution, and number of harmonics in a non-sinusoidal system, on the reactive energy measurement using DWT. The error analysis is depicted in the form of the absolute difference between the measured and the true value of the reactive energy.

  17. Metering Plan: Intelligent Operational Strategies Through Enhanced Metering Systems

    Energy Technology Data Exchange (ETDEWEB)

    Pope, Jason E.

    2016-07-27

    The Sustainability Program at Pacific Northwest National Laboratory (PNNL) has adopted a “triple-bottom-line” approach of environmental stewardship, social responsibility, and economic prosperity to its operations. Metering at PNNL works in support of all three, specifically to measure and inform building energy use and greenhouse gas emissions and minimize water use. The foundation for metering at PNNL is a core goal set, which consists of four objectives: providing accurate data without interruption, analyzing data while it is still new, providing actionable recommendations to operations management, and ensuring PNNL’s compliance with contract metering requirements. These core objectives guide the decisions that we make during annual planning and as we operate throughout the year. This 2016 edition of the Metering Plan conveys the metering practices for and vision of the Sustainability Program. Changes in this plan from the 2015 edition include updated tables and an enhanced discussion on energy tracking systems used at PNNL. This plan also discusses updated benchmarking strategies using PNNL’s graphics and analytics tool, BuildingOS by Lucid Design Group. This plan presents our progress toward the metering goals shared by all federal agencies and highlights our successful completion of metering requirements. Currently, PNNL is fully compliant with the applicable legislative and Executive Order metering requirements. PNNL’s approach to the installation of new meters will be discussed. Perhaps most importantly, this plan details the analysis techniques utilized at PNNL that rely on the endless streams of data newly available as a result of increased meter deployment over the last several years. Previous Metering Plans have documented specific meter connection schemes as PNNL focused on deploying meters in a first step toward managing energy and water use. This plan serves not only to highlight PNNL’s successful completion of agency metering goals, but

  18. Adaptation of the DP 50 dust meter for measuring dust content under isokinetic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Vitek, J.; Novak, L.

    1985-03-01

    The DP 50 dust meter, developed by the Scientific Coal Research Institute Ostrava-Radvanice, is used for measuring dust content in the air in underground coal mines. Two versions of the system are used: a type developed in 1970 which is placed in a vertical position and used to measure the content of respirable coal particles in the air; and a type developed in 1983 for isokinetic measurement of dust content in the air. The latter is equipped with 8 cone-shaped adapters (with differing size and dimensions of the cone inlet adjusted to air flow rates from 0.25 to 8.00 m/s). Specifications of the 8 adapters are given in a table. The 1983 version of the DP 50 is placed in a horizontal position with the dust meter axis parallel to the direction of air flow ventilating a mine working. Recommendations for installation of dust meters in underground workings and effects of installation on measurement accuracy are discussed. 16 references.

  19. Digital reactivity meter

    International Nuclear Information System (INIS)

    Jiang Zongbing

    1996-02-01

    The importance and the usual methods of reactivity measurement in a nuclear reactor are presented. Emphasis is put upon the calculation principle, software and hardware components, main specifications, application, as well as the features of the digital reactivity meter. The test results of operation in various reactors shown that the meter possess the following features: high accuracy, short response time, low output noise, high resolution, wide measuring range, simple and flexible to operate, high stability and reliability. In addition, the reactivity meter can save the measuring data automatically and have a perfect capability of self-verifying. It not only meet the requirement of the reactivity measurement in nuclear power plant, but also can be applied to various types of reactors. (1 tab.)

  20. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  1. Use of neutron scattering meter to detect soil moisture distribution under trickle irrigation system in sandy soil of inshas, Egypt

    International Nuclear Information System (INIS)

    Abd El-moniem, M.; El-gendy, R.W.; Gadalla, A.M.; Hamdy, A.; Zeedan, A.

    2006-01-01

    This study aims to investigate the soil moisture distribution under different quantities of irrigation water in cultivated sandy soil with squash, using drip irrigation system. This study was carried out in Inshas sandy soil at the farm of Soil and Water Research Department, Nuclear Research Centre, Atomic Energy Authority, Egypt. Three rates of applied irrigation water (100, 75 and 50 % ETc) were used. Three sites (0, 12.5 and 25 cm distances from the emitter between drippers and laterals lines) were chosen to measure soil moisture contents (horizontal and vertical directions within the soil depths). The obtained data pointed out that the maximum width, in onion shape of water distribution under drip irrigation system, was at 45 cm depth at 0 site. From the study of soil moisture distribution, the overlapping between each two neighbor drippers played a good role in increasing soil moisture content at the 25 site rather than the rest sites. Water distribution was affected with plant location within the wet area as well as the used irrigation water quantities. Water distribution between drippers and laterals did not differ much approximately. The highest soil moisture depletion was at 12.5 site (between drippers) for 100 and 75 % ETc rather than the rest treatments. 100 % ETc treatment introduced the highest soil moisture depletion in the first stage of plant growth season for the three sites (between drippers and laterals). In the last stage of plant growth season, water re-distribution phenomena resulted from the changeable total hydraulic potential, which played important role for interpretation of results

  2. Density and moisture measurements by nuclear method and its application to compaction control in road construction

    International Nuclear Information System (INIS)

    Mohd Azmi Ismail

    1994-01-01

    The application of nuclear technique in civil engineering sector which emphasises on the in-situ density and moisture measurements of soil in road construction is discussed. The nuclear density-moisture gauge utilises both gamma-rays and neutrons for the determination of the density and moisture content, respectively. The knowledge on the density and moisture content will be used to evaluate the degree of compaction of the compacted layers. The technique offers not only a fast and non-destructive measurement but it is also accurate, economical and repeatable. A calibration equation which is stored in the built-in microprocessor is applicable for any type of soil. Corrections for the interferences from needless gamma-rays produced as a result of thermal neutrons interaction with certain nuclei for the density measurement and effects of hydrogen other than absorbed water for the moisture measurement are considered in the equation. This paper describes briefly the theory and the characteristics of the nuclear gauge and its application in road construction work

  3. Soil Moisture Active Passive Mission L4_SM Data Product Assessment (Version 2 Validated Release)

    Science.gov (United States)

    Reichle, Rolf Helmut; De Lannoy, Gabrielle J. M.; Liu, Qing; Ardizzone, Joseph V.; Chen, Fan; Colliander, Andreas; Conaty, Austin; Crow, Wade; Jackson, Thomas; Kimball, John; hide

    2016-01-01

    core validation site comparisons indicate that "Version 2" of the L4_SM data product meets the self-imposed L4_SM accuracy requirement, which is formulated in terms of the ubRMSE: the RMSE (Root Mean Square Error) after removal of the long-term mean difference. The overall ubRMSE of the 3-hourly L4_SM surface soil moisture at the 9 km scale is 0.035 cubic meters per cubic meter requirement. The corresponding ubRMSE for L4_SM root zone soil moisture is 0.024 cubic meters per cubic meter requirement. Both of these metrics are comfortably below the 0.04 cubic meters per cubic meter requirement. The L4_SM estimates are an improvement over estimates from a model-only SMAP Nature Run version 4 (NRv4), which demonstrates the beneficial impact of the SMAP brightness temperature data. L4_SM surface soil moisture estimates are consistently more skillful than NRv4 estimates, although not by a statistically significant margin. The lack of statistical significance is not surprising given the limited data record available to date. Root zone soil moisture estimates from L4_SM and NRv4 have similar skill. Results from comparisons of the L4_SM product to in situ measurements from nearly 400 sparse network sites corroborate the core validation site results. The instantaneous soil moisture and soil temperature analysis increments are within a reasonable range and result in spatially smooth soil moisture analyses. The O-F residuals exhibit only small biases on the order of 1-3 degrees Kelvin between the (re-scaled) SMAP brightness temperature observations and the L4_SM model forecast, which indicates that the assimilation system is largely unbiased. The spatially averaged time series standard deviation of the O-F residuals is 5.9 degrees Kelvin, which reduces to 4.0 degrees Kelvin for the observation-minus-analysis (O-A) residuals, reflecting the impact of the SMAP observations on the L4_SM system. Averaged globally, the time series standard deviation of the normalized O-F residuals is

  4. Ground Albedo Neutron Sensing (GANS) method for measurements of soil moisture in cropped fields

    Science.gov (United States)

    Andres Rivera Villarreyes, Carlos; Baroni, Gabriele; Oswald, Sascha E.

    2013-04-01

    Measurement of soil moisture at the plot or hill-slope scale is an important link between local vadose zone hydrology and catchment hydrology. However, so far only few methods are on the way to close this gap between point measurements and remote sensing. This study evaluates the applicability of the Ground Albedo Neutron Sensing (GANS) for integral quantification of seasonal soil moisture in the root zone at the scale of a field or small watershed, making use of the crucial role of hydrogen as neutron moderator relative to other landscape materials. GANS measurements were performed at two locations in Germany under different vegetative situations and seasonal conditions. Ground albedo neutrons were measured at (i) a lowland Bornim farmland (Brandenburg) cropped with sunflower in 2011 and winter rye in 2012, and (ii) a mountainous farmland catchment (Schaefertal, Harz Mountains) since middle 2011. At both sites depth profiles of soil moisture were measured at several locations in parallel by frequency domain reflectometry (FDR) for comparison and calibration. Initially, calibration parameters derived from a previous study with corn cover were tested under sunflower and winter rye periods at the same farmland. GANS soil moisture based on these parameters showed a large discrepancy compared to classical soil moisture measurements. Therefore, two new calibration approaches and four different ways of integration the soil moisture profile to an integral value for GANS were evaluated in this study. This included different sets of calibration parameters based on different growing periods of sunflower. New calibration parameters showed a good agreement with FDR network during sunflower period (RMSE = 0.023 m3 m-3), but they underestimated soil moisture in the winter rye period. The GANS approach resulted to be highly affected by temporal changes of biomass and crop types which suggest the need of neutron corrections for long-term observations with crop rotation. Finally

  5. MoisturEC: a new R program for moisture content estimation from electrical conductivity data

    Science.gov (United States)

    Terry, Neil; Day-Lewis, Frederick D.; Werkema, Dale D.; Lane, John W.

    2018-01-01

    Noninvasive geophysical estimation of soil moisture has potential to improve understanding of flow in the unsaturated zone for problems involving agricultural management, aquifer recharge, and optimization of landfill design and operations. In principle, several geophysical techniques (e.g., electrical resistivity, electromagnetic induction, and nuclear magnetic resonance) offer insight into soil moisture, but data‐analysis tools are needed to “translate” geophysical results into estimates of soil moisture, consistent with (1) the uncertainty of this translation and (2) direct measurements of moisture. Although geostatistical frameworks exist for this purpose, straightforward and user‐friendly tools are required to fully capitalize on the potential of geophysical information for soil‐moisture estimation. Here, we present MoisturEC, a simple R program with a graphical user interface to convert measurements or images of electrical conductivity (EC) to soil moisture. Input includes EC values, point moisture estimates, and definition of either Archie parameters (based on experimental or literature values) or empirical data of moisture vs. EC. The program produces two‐ and three‐dimensional images of moisture based on available EC and direct measurements of moisture, interpolating between measurement locations using a Tikhonov regularization approach.

  6. Techniques for the measurement of trace moisture in high-purity electronic specialty gases

    International Nuclear Information System (INIS)

    Funke, Hans H.; Grissom, Brad L.; McGrew, Clark E.; Raynor, Mark W.

    2003-01-01

    The control of water vapor (moisture) contamination in process gases is critical to the successful manufacture of semiconductor devices. As specified moisture levels have become more stringent, there is a growing demand for more sensitive analytical methods. Instrumental methods currently being used or in development for measuring trace moisture at ppbv levels include Fourier transform infrared spectroscopy, tunable diode laser absorption spectroscopy, cavity ringdown spectroscopy, intracavity laser spectroscopy, electron impact ionization mass spectrometry, and atmospheric pressure ionization mass spectrometry. In addition, sensor-based technologies such as oscillating quartz crystal microbalances, and chilled mirror-, capacitor-, and electrolytic-based hygrometers operate in this regime. These approaches are presented and reviewed. As the success of each trace moisture method is dependent on the degree to which the different process gases interfere with the measurement process, important process gas applications of the techniques are highlighted. Advantages and disadvantages as well as future developments and trends are also presented

  7. Direct observations of rock moisture, a hidden component of the hydrologic cycle.

    Science.gov (United States)

    Rempe, Daniella M; Dietrich, William E

    2018-03-13

    Recent theory and field observations suggest that a systematically varying weathering zone, that can be tens of meters thick, commonly develops in the bedrock underlying hillslopes. Weathering turns otherwise poorly conductive bedrock into a dynamic water storage reservoir. Infiltrating precipitation typically will pass through unsaturated weathered bedrock before reaching groundwater and running off to streams. This invisible and difficult to access unsaturated zone is virtually unexplored compared with the surface soil mantle. We have proposed the term "rock moisture" to describe the exchangeable water stored in the unsaturated zone in weathered bedrock, purposely choosing a term parallel to, but distinct from, soil moisture, because weathered bedrock is a distinctly different material that is distributed across landscapes independently of soil thickness. Here, we report a multiyear intensive campaign of quantifying rock moisture across a hillslope underlain by a thick weathered bedrock zone using repeat neutron probe measurements in a suite of boreholes. Rock moisture storage accumulates in the wet season, reaches a characteristic upper value, and rapidly passes any additional rainfall downward to groundwater. Hence, rock moisture storage mediates the initiation and magnitude of recharge and runoff. In the dry season, rock moisture storage is gradually depleted by trees for transpiration, leading to a common lower value at the end of the dry season. Up to 27% of the annual rainfall is seasonally stored as rock moisture. Significant rock moisture storage is likely common, and yet it is missing from hydrologic and land-surface models used to predict regional and global climate.

  8. On-line moisture analysis

    CERN Document Server

    Cutmore, N G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk mater...

  9. Scintillator power meter applied on Z-pinch plasma soft X-ray yield measurement

    International Nuclear Information System (INIS)

    Zhang Siqun; Huang Xianbin; Li Jing; Dan Jiakun; Li Jun; Yang Libing; Cui Mingqi; Zhao Yidong

    2010-01-01

    This paper presents the configuration and measuring parameters of scintillator power meter applied in Z-pinch plasma soft X-ray yield measurement on Yang accelerator. It also introduces the calibration experiment on BSRF, and analyzes the defect of the power meter from calibration results, the possible errors and feasible method for correcting the errors. The measuring results are revised according to spectrum acquired from Dante spectrometer. The revised discrepancy of two instruments is decreased from over 30% to subter-15%. Finally, the result of yield measurement of the puff Z-pinch X-ray radiation is reported as well, i.e., hundreds of Joule, multigigawatt levels of soft X ray radiation were produced by puff Z-pinch on Yang accelerator. (authors)

  10. Moisture measurement in wood, wood-based materials and building materials - a literature review

    International Nuclear Information System (INIS)

    Kober, A.; Mehlhorn, L.; Plinke, B.

    1989-10-01

    Methods of moisture measurement in solid substances, especially on wood, wood-based materials and building materials were examined and evaluated according to the literature available. The question was which methods of examining the moisture distribution in building elements at climate loading offer the best accuracy and spatial resolution as well as which methods are the most appropriate at present and in future for the solution of measurement problems in the wood and wood-based industry. The most common methods are electric measurement methods which are utilizing either the moisture-depending conductivity or the dielectric constant or the reflectivity of the material for infrared radiation but they offer only a limited accuracy. The same is valid for the rarely used microwave methods or X-ray and NMR tomography. Simple electric methods will further on play an important role in the industrial process measuring technique. For the examination of building elements, methods using nuclear radiation still offer possibilities for a further development. (orig.) With 207 refs., 13 figs [de

  11. Sodium flow measurement in large pipelines of sodium cooled fast breeder reactors with bypass type flow meters

    International Nuclear Information System (INIS)

    Rajan, K.K.; Jayakumar, T.; Aggarwal, P.K.; Vinod, V.

    2016-01-01

    Highlights: • Bypass type permanent magnet flow meters are more suitable for sodium flow measurement. • A higher sodium velocity through the PMFM sensor will increase its sensitivity and resolution. • By modifying the geometry of bypass line, higher sodium velocity through sensor is achieved. • With optimized geometry the sensitivity of bypass flow meter system was increased by 70%. - Abstract: Liquid sodium flow through the pipelines of sodium cooled fast breeder reactor circuits are measured using electromagnetic flow meters. Bypass type flow meter with a permanent magnet flow meter as sensor in the bypass line is selected for the flow measurement in the 800 NB main secondary pipe line of 500 MWe Prototype Fast Breeder Reactor (PFBR), which is at the advanced stage of construction at Kalpakkam. For increasing the sensitivity of bypass flow meters in future SFRs, alternative bypass geometry was considered. The performance enhancement of the proposed geometry was evaluated by experimental and numerical methods using scaled down models. From the studies it is observed that the new configuration increases the sensitivity of bypass flow meter system by around 70%. Using experimentally validated numerical tools the volumetric flow ratio for the bypass configurations is established for the operating range of Reynolds numbers.

  12. NASA's Soil Moisture Active and Passive (SMAP) Mission

    Science.gov (United States)

    Kellogg, Kent; Njoku, Eni; Thurman, Sam; Edelstein, Wendy; Jai, Ben; Spencer, Mike; Chen, Gun-Shing; Entekhabi, Dara; O'Neill, Peggy; Piepmeier, Jeffrey; hide

    2010-01-01

    The Soil Moisture Active-Passive (SMAP) Mission is one of the first Earth observation satellites being formulated by NASA in response to the 2007 National Research Council s Decadal Survey. SMAP will make global measurements of soil moisture at the Earth's land surface and its freeze-thaw state. These measurements will allow significantly improved estimates of water, energy and carbon transfers between the land and atmosphere. Soil moisture measurements are also of great importance in assessing flooding and monitoring drought. Knowledge gained from SMAP observations can help mitigate these natural hazards, resulting in potentially great economic and social benefits. SMAP observations of soil moisture and freeze/thaw timing over the boreal latitudes will also reduce a major uncertainty in quantifying the global carbon balance and help to resolve an apparent missing carbon sink over land. The SMAP mission concept will utilize an L-band radar and radiometer sharing a rotating 6-meter mesh reflector antenna flying in a 680 km polar orbit with an 8-day exact ground track repeat aboard a 3-axis stabilized spacecraft to provide high-resolution and high-accuracy global maps of soil moisture and freeze/thaw state every two to three days. In addition, the SMAP project will use these surface observations with advanced modeling and data assimilation to provide estimates of deeper root-zone soil moisture and net ecosystem exchange of carbon. SMAP recently completed its Phase A Mission Concept Study Phase for NASA and transitioned into Phase B (Formulation and Detailed Design). A number of significant accomplishments occurred during this initial phase of mission development. The SMAP project held several open meetings to solicit community feedback on possible science algorithms, prepared preliminary draft Algorithm Theoretical Basis Documents (ATBDs) for each mission science product, and established a prototype algorithm testbed to enable testing and evaluation of the

  13. Soil moisture dynamics and their effect on bioretention performance in Northeast Ohio

    Science.gov (United States)

    Bush, S. A.; Jefferson, A.; Jarden, K.; Kinsman-Costello, L. E.; Grieser, J.

    2014-12-01

    Urban impervious surfaces lead to increases in stormwater runoff. Green infrastructure, like bioretention cells, is being used to mitigate negative impacts of runoff by disconnecting impervious surfaces from storm water systems and redirecting flow to decentralized treatment areas. While bioretention soil characteristics are carefully designed, little research is available on soil moisture dynamics within the cells and how these might relate to inter-storm variability in performance. Bioretentions have been installed along a residential street in Parma, Ohio to determine the impact of green infrastructure on the West Creek watershed, a 36 km2 subwatershed of the Cuyahoga River. Bioretentions were installed in two phases (Phase I in 2013 and Phase II in 2014); design and vegetation density vary slightly between the two phases. Our research focuses on characterizing soil moisture dynamics of multiple bioretentions and assessing their impact on stormwater runoff at the street scale. Soil moisture measurements were collected in transects for eight bioretentions over the course of one summer. Vegetation indices of canopy height, percent vegetative cover, species richness and NDVI were also measured. A flow meter in the storm drain at the end of the street measured storm sewer discharge. Precipitation was recorded from a meteorological station 2 km from the research site. Soil moisture increased in response to precipitation and decreased to relatively stable conditions within 3 days following a rain event. Phase II bioretentions exhibited greater soil moisture and less vegetation than Phase I bioretentions, though the relationship between soil moisture and vegetative cover is inconclusive for bioretentions constructed in the same phase. Data from five storms suggest that pre-event soil moisture does not control the runoff-to-rainfall ratio, which we use as a measure of bioretention performance. However, discharge data indicate that hydrograph characteristics, such as lag

  14. Exposure to electromagnetic fields from smart utility meters in GB; part I) laboratory measurements.

    Science.gov (United States)

    Peyman, Azadeh; Addison, Darren; Mee, Terry; Goiceanu, Cristian; Maslanyj, Myron; Mann, Simon

    2017-05-01

    Laboratory measurements of electric fields have been carried out around examples of smart meter devices used in Great Britain. The aim was to quantify exposure of people to radiofrequency signals emitted from smart meter devices operating at 2.4 GHz, and then to compare this with international (ICNIRP) health-related guidelines and with exposures from other telecommunication sources such as mobile phones and Wi-Fi devices. The angular distribution of the electric fields from a sample of 39 smart meter devices was measured in a controlled laboratory environment. The angular direction where the power density was greatest was identified and the equivalent isotropically radiated power was determined in the same direction. Finally, measurements were carried out as a function of distance at the angles where maximum field strengths were recorded around each device. The maximum equivalent power density measured during transmission around smart meter devices at 0.5 m and beyond was 15 mWm -2 , with an estimation of maximum duty factor of only 1%. One outlier device had a maximum power density of 91 mWm -2 . All power density measurements reported in this study were well below the 10 W m -2 ICNIRP reference level for the general public. Bioelectromagnetics. 2017;38:280-294. © 2017 Crown copyright. BIOELECTROMAGNETICS © 2017 Wiley Periodicals, Inc. © 2017 Crown copyright. BIOELECTROMAGNETICS © 2017 Wiley Periodicals, Inc.

  15. The neutronic method for measuring soil moisture

    International Nuclear Information System (INIS)

    Couchat, Ph.

    1967-01-01

    The three group diffusion theory being chosen as the most adequate method for determining the response of the neutron soil moisture probe, a mathematical model is worked out using a numerical calculation programme with Fortran IV coding. This model is fitted to the experimental conditions by determining the effect of different parameters of measuring device: channel, fast neutron source, detector, as also the soil behaviour under neutron irradiation: absorbers, chemical binding of elements. The adequacy of the model is tested by fitting a line through the image points corresponding to the couples of experimental and theoretical values, for seven media having different chemical composition: sand, alumina, line stone, dolomite, kaolin, sandy loam, calcareous clay. The model chosen gives a good expression of the dry density influence and allows α, β, γ and δ constants to be calculated for a definite soil according to the following relation which gives the count rate of the soil moisture probe: N = (α ρ s +β) H v +γ ρ s + δ. (author) [fr

  16. Manage costs and revenues by achieving continuous measurement certainty with the Auto-Adjust Turbo Meter; Gerez les couts et les recettes en acquerant une certitude continuelle de mesure grace au Auto-Adjust Turbo Meter

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D. [Invensys Energy Metering, Pennsylvania (United States)

    2000-07-01

    Uncertainty in flow measurement and its consequent ramifications are accepted as normal costs of transporting and distributing natural gas. However, a notable advancement in turbine meter technology, pioneered by Invensys Energy Metering, uses two rotors in a tandem configuration to offer unique capabilities beyond those of the tried-and-proven, single-rotor turbine. A flow meter, which monitors its own performance and adjusts its measurement, on a real-time basis, for any deviations from its initial calibration, could largely eliminate many of the costs and lost revenue associated with flow metering and measurement uncertainty. The dual-rotor turbine, trade named the Auto-Adjust Turbo Meter (AAT), is such a flow meter; it provides Continuous Measurement Certainty, with the accompanying potential for enhanced management of costs and revenues. Proprietary algorithms in the AAT's secondary electronics correlate the velocities of the main rotor and the downstream sensing rotor, over the full range of the meter's rated capacity and pressure, such that a real-time adjustment to the indicated volume corrects it to the actual volume. Improved gas accountability results, and substantial savings related to meter site visits, meter testing and repair, preventive maintenance programs, and measurement disputes can be realized. Test data and case histories from a broad range of end users are related to demonstrate areas of potential savings and revenue recovery. (author)

  17. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  18. MoisturEC: A New R Program for Moisture Content Estimation from Electrical Conductivity Data.

    Science.gov (United States)

    Terry, Neil; Day-Lewis, Frederick D; Werkema, Dale; Lane, John W

    2018-03-06

    Noninvasive geophysical estimation of soil moisture has potential to improve understanding of flow in the unsaturated zone for problems involving agricultural management, aquifer recharge, and optimization of landfill design and operations. In principle, several geophysical techniques (e.g., electrical resistivity, electromagnetic induction, and nuclear magnetic resonance) offer insight into soil moisture, but data-analysis tools are needed to "translate" geophysical results into estimates of soil moisture, consistent with (1) the uncertainty of this translation and (2) direct measurements of moisture. Although geostatistical frameworks exist for this purpose, straightforward and user-friendly tools are required to fully capitalize on the potential of geophysical information for soil-moisture estimation. Here, we present MoisturEC, a simple R program with a graphical user interface to convert measurements or images of electrical conductivity (EC) to soil moisture. Input includes EC values, point moisture estimates, and definition of either Archie parameters (based on experimental or literature values) or empirical data of moisture vs. EC. The program produces two- and three-dimensional images of moisture based on available EC and direct measurements of moisture, interpolating between measurement locations using a Tikhonov regularization approach. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  19. A Compound Sensor for Simultaneous Measurement of Packing Density and Moisture Content of Silage.

    Science.gov (United States)

    Meng, Delun; Meng, Fanjia; Sun, Wei; Deng, Shuang

    2017-12-28

    Packing density and moisture content are important factors in investigating the ensiling quality. Low packing density is a major cause of loss of sugar content. The moisture content also plays a determinant role in biomass degradation. To comprehensively evaluate the ensiling quality, this study focused on developing a compound sensor. In it, moisture electrodes and strain gauges were embedded into an ASABE Standard small cone for the simultaneous measurements of the penetration resistance (PR) and moisture content (MC) of silage. In order to evaluate the performance of the designed sensor and the theoretical analysis being used, relevant calibration and validation tests were conducted. The determination coefficients are 0.996 and 0.992 for PR calibration and 0.934 for MC calibration. The validation indicated that this measurement technique could determine the packing density and moisture content of the silage simultaneously and eliminate the influence of the friction between the penetration shaft and silage. In this study, we not only design a compound sensor but also provide an alternative way to investigate the ensiling quality which would be useful for further silage research.

  20. A tube seepage meter for in situ measurement of seepage rate and groundwater sampling

    Science.gov (United States)

    Solder, John; Gilmore, Troy E.; Genereux, David P.; Solomon, D. Kip

    2016-01-01

    We designed and evaluated a “tube seepage meter” for point measurements of vertical seepage rates (q), collecting groundwater samples, and estimating vertical hydraulic conductivity (K) in streambeds. Laboratory testing in artificial streambeds show that seepage rates from the tube seepage meter agreed well with expected values. Results of field testing of the tube seepage meter in a sandy-bottom stream with a mean seepage rate of about 0.5 m/day agreed well with Darcian estimates (vertical hydraulic conductivity times head gradient) when averaged over multiple measurements. The uncertainties in q and K were evaluated with a Monte Carlo method and are typically 20% and 60%, respectively, for field data, and depend on the magnitude of the hydraulic gradient and the uncertainty in head measurements. The primary advantages of the tube seepage meter are its small footprint, concurrent and colocated assessments of q and K, and that it can also be configured as a self-purging groundwater-sampling device.

  1. Knowledge is power: Customer load metering in the Victorian End-Use Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Gavin, G. [CitiPower Ltd., Melbourne, VIC (Australia)

    1995-12-31

    The Victorian End-Use Measurement Program is a sophisticated load metering program being conducted over 500 sites in Victoria, covering the major customer sectors of residential, commercial and industrial. Its goal is to gather sufficient data to determine with statistical accuracy the load profiles of these major sectors, together with the load profiles of selected customer end-uses in the residential and commercial sectors, and selected building types in the commercial sector. This paper discusses the major elements of the program, the history of its development, the design of the statistical and operational components of the program, and its implementation in the field. In the Victorian electricity industry, with the combination of contestable customer metering and the End-Use Measurement program metering for the franchise/non-contestable market, there is now a considerable flow of customer load data. The opportunity exists for an accurate understanding of customer load needs, and the minimization of risk in business operations in the retail and wholesale market. (author).

  2. Moisture disturbance when measuring boron content in wet glass fibre materials with thermal neutron transmission method

    International Nuclear Information System (INIS)

    Zhang Zhiping; Liu Shengkang; Zhang Yongjie

    2001-01-01

    The theoretical calculation and experimental study on the moisture disturbance in the boron content measurement of wet glass fibre materials using the thermal neutron transmission method were reported. The relevant formula of the moisture disturbance was derived. For samples with a mass of 16 g, it was found that a moisture variation of 1% (mass percent) would result in a deviation of 0.28% (mass percent) in the measurement of boron contents

  3. Hysteresis and Temperature Dependency of Moisture Sorption – New Measurements

    DEFF Research Database (Denmark)

    Rode, Carsten; Hansen, Kurt Kielsgaard

    2011-01-01

    measurements of hysteresis and temperature dependency of the moisture sorption characteristics of three different porous building materials: aerated concrete, cement paste and spruce. Scanning curves are measured for all three materials where periods with adsorption and desorption interrupt each other...... intermittently. For one of the materials, aerated concrete, the sorption curves are determined at three different temperatures....

  4. On-line moisture analysis

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Mijak, D.G

    2002-01-01

    Measurement of the moisture content of iron ore has become a key issue for controlling moisture additions for dust suppression. In most cases moisture content is still determined by manual or automatic sampling of the ore stream, followed by conventional laboratory analysis by oven drying. Although this procedure enables the moisture content to be routinely monitored, it is too slow for control purposes. This has generated renewed interest in on-line techniques for the accurate and rapid measurement of moisture in iron ore on conveyors. Microwave transmission techniques have emerged over the past 40 years as the dominant technology for on-line measurement of moisture in bulk materials, including iron ores. Alternative technologies have their limitations. Infra-red analysers are used in a variety of process industries, but rely on the measurement of absorption by moisture in a very thin surface layer. Consequently such probes may be compromised by particle size effects and biased presentation of the bulk material. Nuclear-based analysers measure the total hydrogen content in the sample and do not differentiate between free and combined moisture. Such analysers may also be sensitive to material presentation and elemental composition. Very low frequency electromagnetic probes, such as capacitance or conductance probes, operate in the frequency region where the DC conductivity dominates much of the response, which is a function not only of moisture content but also of ionic composition and chemistry. These problems are overcome using microwave transmission techniques, which also have the following advantages, as a true bulk moisture analysis is obtained, because a high percentage of the bulk material is analysed; the moisture estimate is mostly insensitive to any biased presentation of moisture, for example due to stratification of bulk material with different moisture content and because no physical contact is made between the sensor and the bulk material. This is

  5. Soil Moisture Active Passive (SMAP) Mission Level 4 Surface and Root Zone Soil Moisture (L4_SM) Product Specification Document

    Science.gov (United States)

    Reichle, Rolf H.; Ardizzone, Joseph V.; Kim, Gi-Kong; Lucchesi, Robert A.; Smith, Edmond B.; Weiss, Barry H.

    2015-01-01

    This is the Product Specification Document (PSD) for Level 4 Surface and Root Zone Soil Moisture (L4_SM) data for the Science Data System (SDS) of the Soil Moisture Active Passive (SMAP) project. The L4_SM data product provides estimates of land surface conditions based on the assimilation of SMAP observations into a customized version of the NASA Goddard Earth Observing System, Version 5 (GEOS-5) land data assimilation system (LDAS). This document applies to any standard L4_SM data product generated by the SMAP Project. The Soil Moisture Active Passive (SMAP) mission will enhance the accuracy and the resolution of space-based measurements of terrestrial soil moisture and freeze-thaw state. SMAP data products will have a noteworthy impact on multiple relevant and current Earth Science endeavors. These include: Understanding of the processes that link the terrestrial water, the energy and the carbon cycles, Estimations of global water and energy fluxes over the land surfaces, Quantification of the net carbon flux in boreal landscapes Forecast skill of both weather and climate, Predictions and monitoring of natural disasters including floods, landslides and droughts, and Predictions of agricultural productivity. To provide these data, the SMAP mission will deploy a satellite observatory in a near polar, sun synchronous orbit. The observatory will house an L-band radiometer that operates at 1.40 GHz and an L-band radar that operates at 1.26 GHz. The instruments will share a rotating reflector antenna with a 6 meter aperture that scans over a 1000 km swath.

  6. Direct observations of rock moisture, a hidden component of the hydrologic cycle

    Science.gov (United States)

    Rempe, Daniella M.; Dietrich, William E.

    2018-03-01

    Recent theory and field observations suggest that a systematically varying weathering zone, that can be tens of meters thick, commonly develops in the bedrock underlying hillslopes. Weathering turns otherwise poorly conductive bedrock into a dynamic water storage reservoir. Infiltrating precipitation typically will pass through unsaturated weathered bedrock before reaching groundwater and running off to streams. This invisible and difficult to access unsaturated zone is virtually unexplored compared with the surface soil mantle. We have proposed the term “rock moisture” to describe the exchangeable water stored in the unsaturated zone in weathered bedrock, purposely choosing a term parallel to, but distinct from, soil moisture, because weathered bedrock is a distinctly different material that is distributed across landscapes independently of soil thickness. Here, we report a multiyear intensive campaign of quantifying rock moisture across a hillslope underlain by a thick weathered bedrock zone using repeat neutron probe measurements in a suite of boreholes. Rock moisture storage accumulates in the wet season, reaches a characteristic upper value, and rapidly passes any additional rainfall downward to groundwater. Hence, rock moisture storage mediates the initiation and magnitude of recharge and runoff. In the dry season, rock moisture storage is gradually depleted by trees for transpiration, leading to a common lower value at the end of the dry season. Up to 27% of the annual rainfall is seasonally stored as rock moisture. Significant rock moisture storage is likely common, and yet it is missing from hydrologic and land-surface models used to predict regional and global climate.

  7. 40 CFR 201.23 - Test site, weather conditions and background noise criteria for measurement at a 30 meter (100...

    Science.gov (United States)

    2010-07-01

    ... background noise criteria for measurement at a 30 meter (100 feet) distance of the noise from locomotive and... and background noise criteria for measurement at a 30 meter (100 feet) distance of the noise from... meters (4 feet) above the ground at the microphone location, except as provided in paragraph (c) of this...

  8. The accuracy and limitations of a new meter used to measure aqueous carbon dioxide

    DEFF Research Database (Denmark)

    Moran, Damian; Tirsgård, Bjørn; Steffensen, John F.

    2010-01-01

    The OxyGuard CO2 Analyzer is a novel meter that can directly measure aqueous CO2 gas pressure using a water-resistant gas-permeable membrane and infra-red absorption cell. The pCO2 is converted to a concentration via a solubility factor determined from the calibration procedure and a thermistor. We...... not appreciably affect reaction time. The meter had a precision of ±0.5 mg L−1 CO2(aq), and high linearity (correlation 0.99–1.01) above 1 mg L−1 in both freshwater and seawater. The standard meter will not be useful for measuring low concentrations such as atmospheric CO2 levels, but will be useful in situations...... where accurate pH and carbonate alkalinity determinations are difficult to obtain, such as saline waters and waters of high organic loadings....

  9. Measurement of microchannel fluidic resistance with a standard voltage meter.

    Science.gov (United States)

    Godwin, Leah A; Deal, Kennon S; Hoepfner, Lauren D; Jackson, Louis A; Easley, Christopher J

    2013-01-03

    A simplified method for measuring the fluidic resistance (R(fluidic)) of microfluidic channels is presented, in which the electrical resistance (R(elec)) of a channel filled with a conductivity standard solution can be measured and directly correlated to R(fluidic) using a simple equation. Although a slight correction factor could be applied in this system to improve accuracy, results showed that a standard voltage meter could be used without calibration to determine R(fluidic) to within 12% error. Results accurate to within 2% were obtained when a geometric correction factor was applied using these particular channels. When compared to standard flow rate measurements, such as meniscus tracking in outlet tubing, this approach provided a more straightforward alternative and resulted in lower measurement error. The method was validated using 9 different fluidic resistance values (from ∼40 to 600kPa smm(-3)) and over 30 separately fabricated microfluidic devices. Furthermore, since the method is analogous to resistance measurements with a voltage meter in electrical circuits, dynamic R(fluidic) measurements were possible in more complex microfluidic designs. Microchannel R(elec) was shown to dynamically mimic pressure waveforms applied to a membrane in a variable microfluidic resistor. The variable resistor was then used to dynamically control aqueous-in-oil droplet sizes and spacing, providing a unique and convenient control system for droplet-generating devices. This conductivity-based method for fluidic resistance measurement is thus a useful tool for static or real-time characterization of microfluidic systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Homogeneity of a Global Multisatellite Soil Moisture Climate Data Record

    Science.gov (United States)

    Su, Chun-Hsu; Ryu, Dongryeol; Dorigo, Wouter; Zwieback, Simon; Gruber, Alexander; Albergel, Clement; Reichle, Rolf H.; Wagner, Wolfgang

    2016-01-01

    Climate Data Records (CDR) that blend multiple satellite products are invaluable for climate studies, trend analysis and risk assessments. Knowledge of any inhomogeneities in the CDR is therefore critical for making correct inferences. This work proposes a methodology to identify the spatiotemporal extent of the inhomogeneities in a 36-year, global multisatellite soil moisture CDR as the result of changing observing systems. Inhomogeneities are detected at up to 24 percent of the tested pixels with spatial extent varying with satellite changeover times. Nevertheless, the contiguous periods without inhomogeneities at changeover times are generally longer than 10 years. Although the inhomogeneities have measurable impact on the derived trends, these trends are similar to those observed in ground data and land surface reanalysis, with an average error less than 0.003 cubic meters per cubic meter per year. These results strengthen the basis of using the product for long-term studies and demonstrate the necessity of homogeneity testing of multisatellite CDRs in general.

  11. Quality assurance measures and calibration of contamination meters at FAG-Kugelfischer

    International Nuclear Information System (INIS)

    Schloesser, H.

    1992-01-01

    The quality assurance measures taken in connection with the production of contamination meters according to the DIN 44801 standard are explained with regard to the individual components of such instruments, which include mechanical, electronic and detector elements. After the relevant calibration procedures have been described, the author proceeds to draw the reader's attention to potentials for error in measurements of surface contamination. (orig.) [de

  12. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  13. Quantitation of 24-Hour Moisturization by Electrical Measurements of Skin Hydration.

    Science.gov (United States)

    Wickett, R Randall; Damjanovic, Bronson

    The purpose of this study was to quantify the effects of several moisturizers on hydration of the stratum corneum by measuring their effect on electrical conductance over a 24-hour period. Double-blind, randomized controlled trial. Twenty-five healthy female volunteers aged 18 to 65 years with dry skin on the lower legs and no other known dermatologic pathology participated in the study. Additional exclusion criteria were pregnant or taking anti-inflammatory steroids. The study was carried out in a clinical research facility in Winnipeg, Manitoba, Canada. Subjects underwent a 3-day conditioning period using a natural soap bar on the lower legs and no application of moisturizer to the skin. Participants then came to the test site and equilibrated for at least 30 minutes under controlled conditions of temperature and humidity. After baseline hydration measurements on test sites on the lower legs of each subject, a single application of each of 5 test products at a dose of 2 mg/cm was made. Skin hydration was assessed by electrical conductance measurements with a specialized probe. The probe was briefly placed on the skin surface with light pressure, and the measurement recorded in units of microsiemens (μS). Conductance was measured at 2, 4, 6, 8, and 24 hours after product applications. Although all but 1 of the test products increased conductance at 2 hours, only 2 moisturizers containing high levels of glycerin (products C and E) maintained increased conductance relative to baseline at 24 hours, +37.8 (P skin conductance for at least 24 hours after a single application.

  14. A study on the measurement of coal moisture by the neutron method

    International Nuclear Information System (INIS)

    Ma Yonghe

    1985-01-01

    The paper reports the result of measuring coal moisture by the neutron method. A deducting intercept method is used to eliminate the effects of the structural hydrogen and the matrix effect. A measuring device has been developed and its measuring accuracy is less than 1%

  15. Measurements of volatile compound contents in resins using a moisture analyzer.

    Science.gov (United States)

    Hashimoto, Masanori; Nagano, Futami; Endo, Kazuhiko; Ohno, Hiroki

    2010-02-01

    The contents of volatile adhesive compounds, such as water, solvents, and residual unpolymerized monomers, affect the integrity and durability of adhesive bonding. However, there is no method available that can be used to rapidly assess the residual solvent or water contents of adhesive resins. This study examined the effectiveness of a digital moisture analyzer to measure the volatile compound contents of resins. Five self-etching adhesives and seven experimental light-cured resins prepared with different contents (0, 10, and 20% by weight) of water or solvents (acetone and ethanol) were examined in this study. The resins were prepared using different methods (with and without air blast or light-curing) to simulate the clinical conditions of adhesive application. Resin weight changes (% of weight loss) were determined as the residual volatile compound contents, using the moisture analyzer. After the measurements, the resin films were examined using a scanning electron microscope. The weight changes of the resins were found to depend on the amount of water or solvents evaporating from the resin. Water and solvents were evaporated by air blast or light-curing, but some of the water and solvents remained in the cured resin. The moisture analyzer is easy to operate and is a useful instrument for using to measure the residual volatile compound contents of adhesive resin.

  16. Moisture Monitoring at Area G, Technical Area 54, Los Alamos National Laboratory, 2016 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Levitt, Daniel Glenn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Jennings, Terry L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); French, Sean B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-17

    Hydrological characterization and moisture monitoring activities provide data required for evaluating the transport of subsurface contaminants in the unsaturated and saturated zones beneath Area G, and for the Area G Performance Assessment and Composite Analysis. These activities have been ongoing at Area G, Technical Area 54 of the Los Alamos National Laboratory since waste disposal operations began in 1957. This report summarizes the hydrological characterization and moisture monitoring activities conducted at Area G. It includes moisture monitoring data collected from 1986 through 2016 from numerous boreholes and access tubes with neutron moisture meters, as well as data collected by automated dataloggers for water content measurement sensors installed in a waste disposal pit cover, and buried beneath the floor of a waste disposal pit. This report is an update of a nearly identical report by Levitt et al., (2015) that summarized data collected through early 2015; this report includes additional moisture monitoring data collected at Pit 31 and the Pit 38 extension through December, 2016. It also includes information from the Jennings and French (2009) moisture monitoring report and includes all data from Jennings and French (2009) and the Draft 2010 Addendum moisture monitoring report (Jennings and French, 2010). For the 2015 version of this report, all neutron logging data, including neutron probe calibrations, were investigated for quality and pedigree. Some data were recalculated using more defensible calibration data. Therefore, some water content profiles are different from those in the Jennings and French (2009) report. All of that information is repeated in this report for completeness. Monitoring and characterization data generally indicate that some areas of the Area G vadose zone are consistent with undisturbed conditions, with water contents of less than five percent by volume in the top two layers of the Bandelier tuff at Area G. These data also

  17. Soil sample moisture content as a function of time during oven drying for gamma-ray spectroscopic measurements

    International Nuclear Information System (INIS)

    Benke, R.R.; Kearfott, K.J.

    1999-01-01

    In routine gamma-ray spectroscopic analysis of collected soil samples, procedure often calls to remove soil moisture by oven drying overnight at a temperature of 100 deg. C . Oven drying not only minimizes the gamma-ray self-attenuation of soil samples due to the absence of water during the gamma-ray spectroscopic analysis, but also allows for a straightforward calculation of the specific activity of radionuclides in soil, historically based on the sample dry weight. Because radon exhalation is strongly dependent on moisture , knowledge of the oven-drying time dependence of the soil moisture content, combined with radon exhalation measurements during oven drying and at room temperature for varying soil moisture contents, would allow conclusions to be made on how the oven-drying radon exhalation rate depends on soil moisture content. Determinations of the oven-drying radon exhalation from soil samples allow corrections to be made for the immediate laboratory gamma-ray spectroscopy of radionuclides in the natural uranium decay chain. This paper presents the results of soil moisture content measurements during oven drying and suggests useful empirical fits to the moisture data

  18. Investigation of the response of a neutron moisture meter using a multigroup, two-dimensional diffusion theory code

    International Nuclear Information System (INIS)

    Ritchie, A.I.M.; Wilson, D.J.

    1984-12-01

    A multigroup diffusion code has been used to predict the count rate from a neutron moisture meter for a range of values of soil water content ω, thermal neutron absorption cross section Ssub(a) (defined as Σsub(a)/rho) of the soil matrix and soil matrix density rho. Two dimensions adequately approximated the geometry of the source, detector and soil surrounding the detector. Seven energy groups, the data for which were condensed from 128 group data set over the neutron energy spectrum appropriate to the soil-water mixture under study, proved adequate to describe neutron slowing-down and diffusion. The soil-water mixture was an SiO 2 →water mixture, with the absorption cross section of SiO 2 increased to cover the range of Σsub(a) required. The response to changes in matrix density is, in general, linear but the response to changes in water content is not linear over the range of parameter values investigated. Tabular results are presented which allow interpolation of the response for a particular ω, Ssub(a) and rho. It is shown that R(ω, Ssub(a), rho) rho M(Ssub(a)) + C(ω) is a crude representation of the response over a very limited range of variation of ω, and Ssub(a). As the response is a slowly varying function of rho, Ssub(a) and ω, a polynomial fit will provide a better estimate of the response for values of rho, Ssub(a) and ω not tabulated

  19. TAKING VARIOUS AGRO-TECHNICAL MEASURES FOR THE PRESERVATION AND ACCUMULATION OF MOISTURE

    Directory of Open Access Journals (Sweden)

    M. B. Khalilov

    2016-01-01

    Full Text Available ARTICLE RETRACTEDAim. The aim is to conduct a theoretical study of the conditions of occurrence of surface runoff and take technical measures for its prevention.Discussion. The occurrence of surface runoff is possible on condition that the intensity of moisture entry per time unit is greater than the intensity of its absorption and passage through the topsoil. Conditions of surface runoff occur at high intensity of moisture entering the soil surface which can be in the case of heavy rainfall, low water permeability of topsoil as a result of the increased density. The upper topsoil not affected by loosening passes moisture worse than loosened. Low water conductivity of the arable layer may be due to the fact that it is saturated with moisture up to the limit, and the underlying subsoil layers do not absorb or absorb not enough water, pass water less than enters through the upper topsoil. This phenomenon leads to oversaturation of the top plowed layer by water, which can lead to water erosion and landslide.Conclusion. We obtained analytical expressions describing the process of accumulation of moisture in the soil and the formation of surface runoff, which also allow to theoretically justify the need for different agronomic techniques impact on soil. We should select tools and soil impact techniques in order to preserve and accumulate moisture with account of the certain agrolandscape conditions specific to these fields.

  20. Measuring of the moisture content in brick walls of historical buildings - the overview of methods

    Science.gov (United States)

    Hola, A.

    2017-10-01

    The paper deals with the issue of measuring the moisture content of brick walls in buildings of high historical value. It includes a classification of known methods used to measure the moisture content and their valorisation with regards to the legitimacy of using them in historical buildings. Moreover, the most important considerations for conducting such measurements are also described, which include the choice of an appropriate method for a specific situation, the determination of a correlative or hypothetical dependency for equipment used in tests and also the method of distributing measurement points.

  1. L-band HIgh Spatial Resolution Soil Moisture Mapping using SMALL UnManned Aerial Systems

    Science.gov (United States)

    Dai, E.; Venkitasubramony, A.; Gasiewski, A. J.; Stachura, M.; Elston, J. S.; Walter, B.; Lankford, D.; Corey, C.

    2017-12-01

    Soil moisture is of fundamental importance to many hydrological, biological and biogeochemical processes, plays an important role in the development and evolution of convective weather and precipitation, water resource management, agriculture, and flood runoff prediction. The launch of NASA's Soil Moisture Active/Passive (SMAP) mission in 2015 provided new passive global measurements of soil moisture and surface freeze/thaw state at fixed crossing times and spatial resolutions of 36 km. However, there exists a need for measurements of soil moisture on much smaller spatial scales and arbitrary diurnal times for SMAP validation, precision agriculture and evaporation and transpiration studies of boundary layer heat transport. The Lobe Differencing Correlation Radiometer (LDCR) provides a means of mapping soil moisture on spatial scales as small as several meters. Compared with other methods of validation based on either in-situ measurements [1,2] or existing airborne sensors suitable for manned aircraft deployment [3], the integrated design of the LDCR on a lightweight small UAS (sUAS) is capable of providing sub-watershed ( km scale) coverage at very high spatial resolution ( 15 m) suitable for scaling studies, and at comparatively low operator cost. To demonstrate the LDCR several flights had been performed during field experiments at the Canton Oklahoma Soilscape site and Yuma Colorado Irrigation Research Foundation (IRF) site in 2015 and 2016, respectively, using LDCR Revision A and Tempest sUAS. The scientific intercomparisons of LDCR retrieved soil moisture and in-situ measurements will be presented. LDCR Revision B has been built and integrated into SuperSwift sUAS and additional field experiments will be performed at IRF in 2017. In Revision B the IF signal is sampled at 80 MS/s to enable digital correlation and RFI mitigation capabilities, in addition to analog correlation. [1] McIntyre, E.M., A.J. Gasiewski, and D. Manda D, "Near Real-Time Passive C

  2. Drought monitoring with soil moisture active passive (SMAP) measurements

    Science.gov (United States)

    Mishra, Ashok; Vu, Tue; Veettil, Anoop Valiya; Entekhabi, Dara

    2017-09-01

    Recent launch of space-borne systems to estimate surface soil moisture may expand the capability to map soil moisture deficit and drought with global coverage. In this study, we use Soil Moisture Active Passive (SMAP) soil moisture geophysical retrieval products from passive L-band radiometer to evaluate its applicability to forming agricultural drought indices. Agricultural drought is quantified using the Soil Water Deficit Index (SWDI) based on SMAP and soil properties (field capacity and available water content) information. The soil properties are computed using pedo-transfer function with soil characteristics derived from Harmonized World Soil Database. The SMAP soil moisture product needs to be rescaled to be compatible with the soil parameters derived from the in situ stations. In most locations, the rescaled SMAP information captured the dynamics of in situ soil moisture well and shows the expected lag between accumulations of precipitation and delayed increased in surface soil moisture. However, the SMAP soil moisture itself does not reveal the drought information. Therefore, the SMAP based SWDI (SMAP_SWDI) was computed to improve agriculture drought monitoring by using the latest soil moisture retrieval satellite technology. The formulation of SWDI does not depend on longer data and it will overcome the limited (short) length of SMAP data for agricultural drought studies. The SMAP_SWDI is further compared with in situ Atmospheric Water Deficit (AWD) Index. The comparison shows close agreement between SMAP_SWDI and AWD in drought monitoring over Contiguous United States (CONUS), especially in terms of drought characteristics. The SMAP_SWDI was used to construct drought maps for CONUS and compared with well-known drought indices, such as, AWD, Palmer Z-Index, sc-PDSI and SPEI. Overall the SMAP_SWDI is an effective agricultural drought indicator and it provides continuity and introduces new spatial mapping capability for drought monitoring. As an

  3. Data quality objectives for moisture measurement in stabilized special nuclear material

    International Nuclear Information System (INIS)

    Weier, D.R.; Pulsipher, B.A.; Silvers, K.L.

    2000-01-01

    Data Quality Objectives methodology is applied to Loss-on-Ignition (LOI) moisture content testing for stabilized nuclear materials. This work was performed by Pacific Northwest National Laboratory in support of the Plutonium Finishing Plant (PFP)/Fluor Hanford, Inc. Historical results on LOI test results for two material types, oxide and sludge, are used to estimate within container variability. This variability estimate is then used in formulating the two recommended acceptance criteria for containers of material. The criteria which follow are proposed to replace the current criterion, which requires recycle if either of two container LOI measurements exceed 0.5 wt%, the DOE Standard 3013-99 threshold value. (1) The 95% upper confidence limit (UCL) for the true mean underlying moisture content in the container material should be less than 0.5 wt%. (2) The difference between the two LOI measurements per container should not exceed their expected 95th percentile relative to the estimated variability. Containers not meeting the first criterion, or those that generate in any negative LOI result, require material recycle. Containers not meeting the second criteria require review of the measurement results, potentially leading to resampling and retesting. Data from Los Alamos National Laboratory studies on moisture testing are obtained and analyzed. The performance of Supercritical Fluid Extraction (SFE), which will soon be implemented at the PFP, is described for several material types. This information will be used to establish initial acceptance criteria when SFE comes on line

  4. Comparing Evapotranspiration Rates Estimated from Atmospheric Flux and TDR Soil Moisture Measurements

    DEFF Research Database (Denmark)

    Schelde, Kirsten; Ringgaard, Rasmus; Herbst, Mathias

    2011-01-01

    limit estimate (disregarding dew evaporation) of evapotranspiration on dry days. During a period of 7 wk, the two independent measuring techniques were applied in a barley (Hordeum vulgare L.) field, and six dry periods were identified. Measurements of daily root zone soil moisture depletion were...

  5. Electric Properties Measurement of Lentil

    Directory of Open Access Journals (Sweden)

    Novák Ján

    2018-03-01

    Full Text Available This paper contains the results of the electric properties measurement of lentil set. Electric measurements with use of these materials are of fundamental importance in relation to the analysis of quantity of absorbed water and dielectric heating characteristics. The aim of this paper was to perform the measurements of conductivity, dielectric constant and loss tangent on samples of lentil, the electrical properties of which had not been sufficiently measured. Measurements were performed under various moisture contents, and the frequency of electric field ranged from 1 MHz to 16 MHz, using a Q meter with coaxial probe. It was concluded that conductivity, relative permittivity and loss tangent increased with an increase in moisture content, and dielectric constant and loss tangent decreased as the frequency of electric field increased.

  6. Smart meter incorporating UWB technology

    NARCIS (Netherlands)

    Khan, T.A.; Khan, A.B.; Babar, M.; Taj, T.A.

    2014-01-01

    Smart Meter is a key element in the evolving concept of Smart Grid, which plays an important role in interaction between the consumer and the supplier. In general, the smart meter is an intelligent digital energy meter that measures the consumption of electrical energy and provides other additional

  7. Evaluation of different disinfectants on the performance of an on-meter dosed amperometric glucose-oxidase-based glucose meter.

    Science.gov (United States)

    Sarmaga, Don; Dubois, Jeffrey A; Lyon, Martha E

    2011-11-01

    Off-meter dosed photometric glucose-oxidase-based glucose meters have been reported to be susceptible to interference by hydrogen-peroxide-based disinfecting agents. The objective of this study was to determine if a single application of hydrogen-peroxide-containing Accel® wipe to disinfect an on-meter dosed amperometric glucose-oxidase-based glucose meter will influence its performance. The performance of five on-meter dosed amperometric glucose-oxidase-based glucose meters was determined before and after disinfecting the devices with a single application of either CaviWipes® (14.3% isopropanol and 0.23% diisobutyl-phenoxy-ethoxyethyl dimethyl benzyl ammonium chloride) or Accel (0.5% hydrogen peroxide) wipes. Replicate glucose measurements were conducted before disinfecting the devices, immediately after disinfecting, and then 1 and 2 min postdisinfecting, with measurements in triplicate. Analysis was sequentially completed for five different meters. Results were analyzed by a two-way analysis of variance (Analyze-it software). No clinical ( .05) in glucose concentration were detected when the on-meter dosed amperometric glucose-oxidase-based glucose meters were disinfected with either CaviWipes or Accel wipes and measured immediately or 1 or 2 min postdisinfecting. No clinically significant difference in glucose concentration was detected between meters (glucose oxidase amperometric-based glucose meters are not analytically susceptible to interference by a single application of hydrogen-peroxide-containing Accel disinfectant wipes. © 2011 Diabetes Technology Society.

  8. Current Measurements and Overwash Monitoring Using Tilt Current Meters in Three Coastal Environments

    Science.gov (United States)

    Lowell, N. S.; Sherwood, C. R.; Decarlo, T. M.; Grant, J. R.

    2014-12-01

    Tilt Current Meters (TCMs) provide accurate, cost effective measurements of near-bottom current velocities. Many studies in coastal environments require current measurements, which are frequently made with Acoustic Doppler Profilers (ADPs). ADPs are expensive, however, and may not be suitable for locations where there is significant risk of damage, loss, or theft or where a large spatial array of measurements is required. TCMs, by contrast, are smaller, less expensive, and easier to deploy. This study tested TCMs in three sites to determine their suitability for use in research applications. TCMs are based on the drag-tilt principle, where the instrument tilts in response to current. The meter consists of a buoyant float with an onboard accelerometer, three-axis tilt sensor, three-axis magnetometer (compass), and a data logger. Current measurements are derived by post processing the tilt and compass values and converting them to velocity using empirical calibration data. Large data-storage capacity (4 GB) and low power requirements allow long deployments (many months) at high sample rates (16 Hz). We demonstrate the utility of TCM current measurements on a reef at Dongsha Atoll in the South China Sea, and in Vineyard Sound off Cape Cod, where the TCM performance was evaluated against ADP measurements. We have also used the TCM to record waves during an overwash event on a Cape Cod barrier beach during a winter storm. The TCM recorded waves as they came through the overwash channel, and the data were in agreement with the water-level record used as a reference. These tests demonstrate that TCMs may be used in a variety of near shore environments and have the potential to significantly increase the density of meters in future studies were current measurements are required.

  9. Measurement of water content in semi-humid sandy land by using IAE-II neutron moisture gauge

    International Nuclear Information System (INIS)

    Feng Qi

    1994-01-01

    The feasibility of using a neutron moisture gauge to study moisture change in semi-humid sandy land was affirmed. The gauge is compact and can rapidly take measurements with small errors. It is found that both the inter-substance boundary surface and the space formed in fixing the neutron tube affect obviously the precision of measurements in the survey process. The calibration variance is the most important part of total uncertainty in measurements

  10. Activity meters: Calibration and quality assurance measures by the manufacturer

    International Nuclear Information System (INIS)

    Pychlau, P.

    1992-01-01

    A manufacturer of ionisation chambers gives a general idea of such quality assurance programs as may be implemented after an agreement has been reached at the EC level on a guideline for activity meters. Further issues discussed include the final controls, calibration of activity meters by the manufacturer and the advantages that the participation in cooperate tests would offer over a mandatory calibration of activity meters. (orig./DG) [de

  11. Measuring spatial and temporal variation in surface moisture on a coastal beach with a near-infrared terrestrial laser scanner

    Science.gov (United States)

    Smit, Yvonne; Ruessink, Gerben; Brakenhoff, Laura B.; Donker, Jasper J. A.

    2018-04-01

    Wind-alone predictions of aeolian sand deposition on the most seaward coastal dune ridge often exceed measured deposition substantially. Surface moisture is a major factor limiting aeolian transport on sandy beaches, but existing measurement techniques cannot adequately characterize the spatial and temporal distribution of surface moisture content. Here, we present a new method for detecting surface moisture at high temporal and spatial resolution using a near-infrared terrestrial laser scanner (TLS), the RIEGL VZ-400. Because this TLS operates at a wavelength (1550 nm) near a water absorption band, TLS reflectance is an accurate parameter to measure surface moisture over its full range. Five days of intensive laser scanning were performed on a Dutch beach to illustrate the applicability of the TLS. Gravimetric surface moisture samples were used to calibrate the relation between reflectance and surface moisture. Results reveal a robust negative relation for the full range of possible surface moisture contents (0%-25%), with a correlation-coefficient squared of 0.85 and a root-mean-square error of 2.7%. This relation holds between 20 and 60 m from the TLS. Within this distance the TLS typically produces O (106-107) data points, which we averaged into surface moisture maps with a 1 × 1 m resolution. This grid size largely removes small reflectance disturbances induced by, for example, footprints or tire tracks, while retaining larger scale moisture trends.

  12. Subcellular Electrical Measurements as a Function of Wood Moisture Content

    Science.gov (United States)

    Samuel L. Zelinka; José L. Colon Quintana; Samuel V. Glass; Joseph E. Jakes; Alex C. Wiedenhoeft

    2015-01-01

    The percolation model developed by Zelinka et al. was based upon macroscale measurements of the electrical conductivity and implicitly treats the wood material as homogenous. The transport mechanism proposed by Jakes et al. depends upon a moisture induced glass transition occurring in the hemicelluloses. This theory suggests that there are likely differences in the...

  13. Measurement of moisture in smoldering smoke and implications for fog

    Science.gov (United States)

    Gary L. Achtemeier

    2006-01-01

    Smoke from wildland burning in association with fog has been implicated as a visibility hazard over roadways in the southern United States. A project began in 2002 to determine whether moisture released during the smoldering phases of southern prescribed burns could contribute to fog formation. Temperature and relative humidity measurements were taken from 27...

  14. On the control of irrigation through soil moisture measurement using a neutron depth probe in horizontal subsurface measuring circuits

    International Nuclear Information System (INIS)

    Schaecke, B.; Schaecke, E.

    1977-01-01

    An outline is given of the advantages inherent in soil moisture measurement by means of a neutron probe in horizontal subsurface measuring circuits for irrigation control. Preliminary experience for the setting up of a field calibration curve and for practical measurement are submitted. This technique includes the following advantages: almost complete covering of the upper soil range which is of interest to irrigation control; good measuring density; suitable distribution of measuring points per unit area; possibility of continuous probe passage; optimal repeatability of measurements; exploration of a unit area with but few measuring circuits; no obstacles to tillage, drilling, intercultivation and harvest operations; and complete conservation of crop and plot which is not reached with any other soil moisture measurement technique so far available. Making use of the above advantages, the new technique allows automatic irrigation control with only one neutron depth probe. (author)

  15. Measured temperature and moisture conditions in the roof attic of a one-and-a-half story house

    DEFF Research Database (Denmark)

    Nielsen, Anker; Morelli, Martin

    2017-01-01

    Temperature and moisture measurements were made in a ventilated attic on a house with 200 mm mineral wool insulation. The measurements showed that 1) solar radiation had a great effect on the temperature in the attic; 2) moisture content reached a level below the risk of mold formation – no mold ...

  16. Streamlining Smart Meter Data Analytics

    OpenAIRE

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, ...

  17. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    Science.gov (United States)

    Krauter, N.; Stefani, F.

    2017-10-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation.

  18. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    International Nuclear Information System (INIS)

    Krauter, N; Stefani, F

    2017-01-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation. (paper)

  19. Magnetic susceptibility and magnetic resonance measurements of the moisture content and hydration condition of a magnetic mixture material

    International Nuclear Information System (INIS)

    Tsukada, K.; Kusaka, T.; Saari, M. M.; Takagi, R.; Sakai, K.; Kiwa, T.; Bito, Y.

    2014-01-01

    We developed a magnetic measurement method to measure the moisture content and hydration condition of mortar as a magnetic mixture material. Mortar is a mixture of Portland cement, sand, and water, and these materials exhibit different magnetic properties. The magnetization–magnetic field curves of these components and of mortars with different moisture contents were measured, using a specially developed high-temperature-superconductor superconducting quantum interference device. Using the differences in magnetic characteristics, the moisture content of mortar was measured at the ferromagnetic saturation region over 250 mT. A correlation between magnetic susceptibility and moisture content was successfully established. After Portland cement and water are mixed, hydration begins. At the early stage of the hydration/gel, magnetization strength increased over time. To investigate the magnetization change, we measured the distribution between bound and free water in the mortar in the early stage by magnetic resonance imaging (MRI). The MRI results suggest that the amount of free water in mortar correlates with the change in magnetic susceptibility

  20. Portable wireless metering

    Energy Technology Data Exchange (ETDEWEB)

    DiPaola, L [Powtel Monitoring Systems, Inc., Ajax, ON (Canada)

    1996-12-31

    Portable meters were discussed as alternatives to standard billing meters for temporary installations. Current, voltage and power factor at a distribution station were measured to calculate kW and kVAR, using an easy to install product that communicates live readings directly to the existing billing system. A background of situations where temporary metering is a possible alternative to regular meters was presented. Use of electronic, clamp on Electronic Recording Ammeters (ERA) and their drawbacks were discussed. An improved temporary metering solution using FM radio transmission to deliver live data to a receiving device, the Eagle Series 3500, was introduced. Improvements over previous ERA systems were discussed, including accuracy, lack of batteries, immediate confirmation of functionality, current, voltage and power factor monitoring, direct feed to billing system, line crew savings, need for only a single unit at any given site, bi-directional power flow metering, independent report storage media, and a portable voltage and P.F. diagnostic tool. Details of trial applications at the Utopia distribution station west of Barrie, ON were presented. This technology was said to be still in the testing stage, but its flexibility and economy were sonsidered to be very promising for future application.

  1. Automatisation of moisture content measurement in biofuel deliveries; Automatiserad fukthaltsmaetning vid braenslemottagning

    Energy Technology Data Exchange (ETDEWEB)

    Aulin, Robert; Hessling, Krister; Karlsson, Mikael; Tryzell, Robert (Bestwood AB, Sundbyberg (Sweden))

    2008-06-15

    Measurement of moisture content in biofuel is normally made through manual sampling near the surface of truck deliveries or in the bulk of fuel deliveries that is distributed on e.g. a storage area. Moisture content is usually performed trough gravimetric determination at lab using oven drying for 24 hours. Precision is approximately a standard deviation of 2 %-units. However, there are several reasons to replace this method by an automatic procedure that measures moisture content in the bulk of the cargo. Except for obtaining more representative samples in the bulk, are speed and the measurement cost important characteristics. The purpose of this project was to develop a well-functioning prototype of a system that is automatic in the sense that manual sampling and sample preparation is replaced by a Near Infra Red (NIR) based system. The intended users of such a system would be both buyers of biofuel and suppliers who would benefit from better knowledge of the quality of the product that they are about to deliver. This project was initiated in the late autumn of 2006. A complete hardware set-up including a NIR spectrophotometer, light probe and a crane was installed in June 2007 in Eskilstuna, Sweden, and shown to members of the reference group at Vaermeforsk. The reliability of reference data obtained through gravimetric measurement was unfortunately not as good as expected on beforehand. This problem was due to the difficulty of obtaining representative samples near the surface of the truck cargo. It delayed the validation phase of this project significantly. An evaluation of the NIR based system reveals a good accuracy and precision that is far better than that of the traditional method for delivery control. A major reason for the superior precision is that the sampling error is reduced. Further, the NIR based system delivers real-time moisture data with a speed that is difficult to reach at lab because of restrictions in manual labour and limitations in

  2. Feasibility study of photodiodes utilization in the soil-moisture determination by gamma transmission

    International Nuclear Information System (INIS)

    Santos, L.A.P. dos.

    1992-08-01

    This study was done to verify the viability of photodiodes, as gamma radiation detector ( 241 Am - Energy=60 KeV), to measure soil water content. The photodiodes used had different mechanical and electrical characteristics, and were tested on soils of different textures. A good linear correlation between the logarithm of the attenuation factor and soil-moisture demonstrated such viability, and that the low photopeak efficiency of these devices is not a limitation to the measurement of soil water content. Furthermore, the stability, the portability, and low cost of such semiconductor devices, including its electronic system, represent relevant characteristics that may justify the development of a reliable gamma meter system for field studies. (author). 37 refs, 21 figs, 20 tabs

  3. A synthetic aperture microwave radiometer to measure soil moisture and ocean salinity from space

    Science.gov (United States)

    Le Vine, D. M.; Hilliard, L. M.; Swift, C. T.; Ruf, C. S.; Garrett, L. B.

    1991-01-01

    A concept is presented for a microwave radiometer in space to measure soil moisture and ocean salinity as part of an 'Earth Probe' mission. The measurements could be made using an array of stick antennas. The L-band channel (1.4 GHz) would be the primary channel for determining soil moisture, with the S-band (2.65-GHz) and C-band (5.0-GHz) channels providing ancillary information to help correct for the effects of the vegetation canopy and possibly to estimate a moisture profile. A preliminary study indicates that an orbit at 450 km would provide coverage of better than 95 percent of the earth every 3 days. A 10-km resolution cell (at nadir) requires stick antennas about 9.5-m long at L-band. The S-band and C-band sticks would be substantially shorter (5 m and 2.7 m, respectively).

  4. Development of a method for the noncontact moisture measurement of different materials at a belt conveyor

    International Nuclear Information System (INIS)

    Frevert, E.

    1991-01-01

    In laboratory tests a method was developed for a contactless moisture measurement at belt conveyors of different materials like coal, clay, industrial slay and stones of inflating clay. The moisture was measured with an 241 Am-Be-neutron source, the absolute necessary determination of the changing flow of material was made with the gamma rays of 137 Cs or 241 Am. The analysis of the records shows, that to all measuring values mathematical defined curves could be found, so that methods of calculation for the moisture content could be deduced. The maximal obtainable accuracy is about ± 0.5 percentage by weight. With the industrial slay and the stones of inflating clay supplementary tests were made direct on the belt conveyor. They show, that also in the practice good results can be obtained. (orig.) [de

  5. Methods of measurement signal acquisition from the rotational flow meter for frequency analysis

    Directory of Open Access Journals (Sweden)

    Świsulski Dariusz

    2017-01-01

    Full Text Available One of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between pulses prohibits the analysis of the measuring signal. Therefore, the authors of the article developed a method involving the determination of measured values on the basis of the last inter-pulse interval preceding the moment designated by the timing generator. For larger changes of the measured value at a predetermined time, the value can be determined by means of extrapolation of the two adjacent interpulse ranges, assuming a linear change in the flow. The proposed methods allow analysis which requires constant spacing between measurements, allowing for an analysis of the dynamics of changes in the test flow, eg. using a Fourier transform. To present the advantages of these methods simulations of flow measurement were carried out with a DRH-1140 rotor flow meter from the company Kobold.

  6. Measuring Neural Entrainment to Beat and Meter in Infants: Effects of Music Background

    Science.gov (United States)

    Cirelli, Laura K.; Spinelli, Christina; Nozaradan, Sylvie; Trainor, Laurel J.

    2016-01-01

    Caregivers often engage in musical interactions with their infants. For example, parents across cultures sing lullabies and playsongs to their infants from birth. Behavioral studies indicate that infants not only extract beat information, but also group these beats into metrical hierarchies by as early as 6 months of age. However, it is not known how this is accomplished in the infant brain. An EEG frequency-tagging approach has been used successfully with adults to measure neural entrainment to auditory rhythms. The current study is the first to use this technique with infants in order to investigate how infants' brains encode rhythms. Furthermore, we examine how infant and parent music background is associated with individual differences in rhythm encoding. In Experiment 1, EEG was recorded while 7-month-old infants listened to an ambiguous rhythmic pattern that could be perceived to be in two different meters. In Experiment 2, EEG was recorded while 15-month-old infants listened to a rhythmic pattern with an unambiguous meter. In both age groups, information about music background (parent music training, infant music classes, hours of music listening) was collected. Both age groups showed clear EEG responses frequency-locked to the rhythms, at frequencies corresponding to both beat and meter. For the younger infants (Experiment 1), the amplitudes at duple meter frequencies were selectively enhanced for infants enrolled in music classes compared to those who had not engaged in such classes. For the older infants (Experiment 2), amplitudes at beat and meter frequencies were larger for infants with musically-trained compared to musically-untrained parents. These results suggest that the frequency-tagging method is sensitive to individual differences in beat and meter processing in infancy and could be used to track developmental changes. PMID:27252619

  7. Electronic meter with custom integrated circuit for electric energy measurement; Medidor eletronico de energia eletrica com circuito integrado dedicado

    Energy Technology Data Exchange (ETDEWEB)

    Caldas, Roberto Pereira

    1990-04-01

    The design and implementation of an electrical energy electronic meter for operation at low voltages, according to two steps of development carried out in Centro de Pesquisas de Energia Eletrica - CEPEL is described. In the first step, an electronic meter with discrete commercial components has been developed, in order to demonstrate to the Brazilian power suppliers the feasibility of such a device for electrical energy metering and charging. The second step was constituted by the design of an integrated circuit, aiming the reduction of the cost of the meter as well as the enhancement of its reliability. Several techniques of electrical energy measurement are presented. The meter with discrete components makes use of a time division multiplier (TDM), in order to determine the active power in the load. Voltage and current levels have been reduced through the use of voltage and current sensors compatible with the TDM's inputs. A V-F converter employing continuos integration, has been used for the determination of the energy consumed by the load through the integration of the TDM's output signal. Most of the discrete components of the meter have been replaced by the dedicated integrated circuit. The TDM has remained essentially the same, but the V-F converter has been changed into a dual-slope one, which is more adequate for implementation in a single chip. The tests performed with the prototypes of the meter including both the meter with discrete components and the meter with the custom-made integrated circuit have presented measurement errors of less the 0,2 %. The initial goal, according to Brazilian specifications of electromechanical meters and international specifications for electronic meters, was 1 %. (author)

  8. Electronic meter with custom integrated circuit for electric energy measurement; Medidor eletronico de energia eletrica com circuito integrado dedicado

    Energy Technology Data Exchange (ETDEWEB)

    Caldas, Roberto Pereira

    1990-04-01

    The design and implementation of an electrical energy electronic meter for operation at low voltages, according to two steps of development carried out in Centro de Pesquisas de Energia Eletrica - CEPEL is described. In the first step, an electronic meter with discrete commercial components has been developed, in order to demonstrate to the Brazilian power suppliers the feasibility of such a device for electrical energy metering and charging. The second step was constituted by the design of an integrated circuit, aiming the reduction of the cost of the meter as well as the enhancement of its reliability. Several techniques of electrical energy measurement are presented. The meter with discrete components makes use of a time division multiplier (TDM), in order to determine the active power in the load. Voltage and current levels have been reduced through the use of voltage and current sensors compatible with the TDM's inputs. A V-F converter employing continuos integration, has been used for the determination of the energy consumed by the load through the integration of the TDM's output signal. Most of the discrete components of the meter have been replaced by the dedicated integrated circuit. The TDM has remained essentially the same, but the V-F converter has been changed into a dual-slope one, which is more adequate for implementation in a single chip. The tests performed with the prototypes of the meter including both the meter with discrete components and the meter with the custom-made integrated circuit have presented measurement errors of less the 0,2 %. The initial goal, according to Brazilian specifications of electromechanical meters and international specifications for electronic meters, was 1 %. (author)

  9. Optical cycle power meter

    DEFF Research Database (Denmark)

    2014-01-01

    A bicycle power meter for measuring power generated when riding a bicycle, the power meter comprising a position-sensitive radiation detector (409) attachable to a component of a crank set (404) of bicycle, and a radiation source (408) attachable to the component of the crank set and configured t...

  10. Fundamental principles of rotary displacement meters

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, J. [Schlumberger Industries, Owenton, KY (United States)

    1995-12-01

    The gas meter exists to continually and accurately measure the volume of gas supplied over the complete flow range of the load. In effect the gas meter serves as the {open_quotes}cash register{close_quotes} of the gas industry; its accurate and dependable performance ensures fair dealings for both the supplier and the user. An investment both in and of itself, the gas meter should be chosen as a function of its usefullness both over the short term and the long term. Thus in addition to initial cost, one must take into account various associated factors, costs and benefits, including the following: Design Characteristics Application, suitability, Meter features and options, Operation constraints, Installation, Service and maintenance, Repair and replacement, Life expectancy, Compatibility with complimentary products, Correcting devices, Remote reading capabilities, Data generation and gathering, Upgradeabilty. This paper will look at one positive displacement meter, the Rotary meter, and address the fundamentals principals of the technology as well as looking at some of the benefits derived from its application. Rotary positive displacement meters were introduced at the end of last century. Used primarily for metering transmission sized loads, the meters` measuring capabilities have extended to cover nearly all areas of distribution with exception of domestic applications. Rotary meters are available in rated capacities from 800 cfh to 102,000 cfh and operating pressures from 175 PSIG to 1440 PSIG. The use of rotary meters on load ranges in the 800 to 10,000 cfh category has increased and is replacing the use of diaphragm meters because of the smaller relative size of rotaries, and improvements in rangeabilities in the last few years. Turbine meters are usually the meter of choice on loads over 16,000 cfh unless a meter with high rangeability is required because of varying load characteristics, in which case a large foot mounted rotary might still be selected.

  11. Apparatus and process for continuous measurement of moisture in moving coal by neutron thermalization

    International Nuclear Information System (INIS)

    Stewart, R.F.

    1967-01-01

    The invention relates to an apparatus and process for the measurement of moisture contents in solid materials. More particularly, the invention makes available a continuous moisture analysis of a moving mass of material, such as coal, by penetrating such material with neutrons emitted from a source of fast neutrons and detecting, counting, and recording slowed or thermalized neutrons reflected from the internal structure of the material. (U.S.)

  12. Estimation of Received Signal Strength Distribution for Smart Meters with Biased Measurement Data Set

    DEFF Research Database (Denmark)

    Kielgast, Mathias Rønholt; Rasmussen, Anders Charly; Laursen, Mathias Hjorth

    2017-01-01

    This letter presents an experimental study and a novel modelling approach of the wireless channel of smart utility meters placed in basements or sculleries. The experimental data consist of signal strength measurements of consumption report packets. Since such packets are only registered if they ......This letter presents an experimental study and a novel modelling approach of the wireless channel of smart utility meters placed in basements or sculleries. The experimental data consist of signal strength measurements of consumption report packets. Since such packets are only registered...... if they can be decoded by the receiver, the part of the signal strength distribution that falls below the receiver sensitivity threshold is not observable. We combine a Rician fading model with a bias function that captures the cut-off in the observed signal strength measurements. Two sets of experimental...... data are analysed. It is shown that the proposed method offers an approximation of the distribution of the signal strength measurements that is better than a naïve Rician fitting....

  13. Multitasking metering enhances generation, transmission operations

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E.

    2008-11-15

    The Dairyland Power Cooperative (DPC) which operates from La Crosse, Wisconsin has the capacity to generate and transmit 1000 MW of power to 25 member cooperatives and 20 municipalities who serve over 500,000 customers. When DPC was experiencing diminished service within its analog cellular-based data communications system, it was presented with an opportunity to install a new automated telecommunications system that would provide secure collection of meter readings from all of its substations. DPC decided to evaluate an advanced multifunctional digital meter from Schweitzer Engineering Laboratories (SEL). The SEL-734 Revenue Metering System offers complete instantaneous metering functions, including voltages, currents, power, energy and power factor. Other capabilities include predictive demand, time-of-use metering, automatic voltage monitoring, harmonics metering and synchrophasor measurement. From a metering perspective, DPC wanted to perform daily load profiles and interval-by-interval metering of their delivery points for billing purposes. They also wanted to provide real-time monitoring of electricity being delivered for both generation and transmission purposes and to make that information available to a distribution SCADA system for their members. The SEL-734 Revenue Meter was well suited to those needs. The SEL-734 provides very high-accuracy energy metering, load profile data collection, instantaneous power measurements, power quality monitoring, and communicates simultaneously over a modem, serial ports, and wide area networks (WAN). The meter is backed with a ten-year warranty as well as field support engineers. 5 figs.

  14. Development of a neutron moisture gauge

    International Nuclear Information System (INIS)

    Prasad, A.S.

    1979-01-01

    A neutron moisture gauge fabricated for measuring the moisture content of coke is described. It has an americium-beryllium source placed beside a boron coated neutron counter which is a slow neutron detector. The fast neutrons emitted by the radioactive source are slowed down by the hydrogen nuclei present in the material either as bound hydrogen or as a hydrogen of the water. Measure of the slowed down i.e. thermal neutrons (their density) is proportional to the total hydrogen content of the material. The instrument is installed as an ''on-line'' measuring device to estimate the moisture content of coke at the weighing hopper feeding the skip car. The accuracy of measurement is dependent on the moisture content, i.e. higher accuracy is obtained for higher moisture content. At low moisture content, the effect of the bound hydrogen other than that of the water on low moisture readings is pronounced. Effect of bulk density on the accuracy of measurement is not very significant as long as the coke size is constant. The error is in the range of +- 1.1%. (M.G.B.)

  15. Equilibrium moisture content of radiata pine at elevated temperature and pressure reveals measurement challenges

    DEFF Research Database (Denmark)

    Pearson, Hamish; Gabbitas, Brian; Ormarsson, Sigurdur

    2012-01-01

    moisture contents were attributed to condensation of liquid water on the specimen with subsequent evaporation at a rate that was too slow for the moisture content to reach equilibrium before it was measured. Reliable EMC data at elevated temperatures require (1) tight process control of experimental......Relatively few studies have been performed on the equilibrium moisture content (EMC) of wood under conditions of elevated temperature and pressure. Eight studies indicated that EMC near saturation decreased between 100 and 150 °C, whilst five studies indicated that EMC increased. The aim...... of this study was to identify the likely source of the disagreement using radiata pine (Pinus radiata D. Don) sapwood which was conditioned to a moisture content of around 3 % and then exposed for 1 h at 150 °C and relative humidities of either 50, 70 or 90 %. Mean values of EMC, obtained through in situ...

  16. Portable neutron moisture gage for the moisture determination of structure parts

    International Nuclear Information System (INIS)

    Harnisch, M.

    1985-01-01

    For determining the moisture of structure parts during building or before repairing a portable neutron moisture gage consisting of a neutron probe and pulse analyzer has been developed. The measuring process, calibration, and prerequisites of application are briefly discussed

  17. Development of model DTY-104 radon measuring meter

    International Nuclear Information System (INIS)

    Shi Zhixia; Zhang Aiming; Li Yachun; Wang Qingheng

    2000-01-01

    Model DTY-104 radon measuring meter is an improvement on Model DTY-103. 'Difference value method' is used, which has been strictly developed and makes the radon exhalation rate more accurate, instead of using 'simplified difference value method'. The electronic circuit is redesigned and 80C31 single chip processor is used, which makes the operation more convenient and the function strengthened. In a more reasonable manner, the humidity sensor is mounted in the collection chamber. The collection efficiency can be automatically corrected. The technique of exchanging the collection mylar reduces the waiting time and improves work efficiency. The apparatus is applied to the measurement of the radon concentration in the environment and the radon exhalation from the surface of the building materials, walls and ground. The lower detection limit is about 4Bq/m 3 for 222 Rn concentration and 5 x 10 -5 Bq/s/m 2 for 222 Rn exhalation rate

  18. Comparisons of Satellite Soil Moisture, an Energy Balance Model Driven by LST Data and Point Measurements

    Science.gov (United States)

    Laiolo, Paola; Gabellani, Simone; Rudari, Roberto; Boni, Giorgio; Puca, Silvia

    2013-04-01

    Soil moisture plays a fundamental role in the partitioning of mass and energy fluxes between land surface and atmosphere, thereby influencing climate and weather, and it is important in determining the rainfall-runoff response of catchments; moreover, in hydrological modelling and flood forecasting, a correct definition of moisture conditions is a key factor for accurate predictions. Different sources of information for the estimation of the soil moisture state are currently available: satellite data, point measurements and model predictions. All are affected by intrinsic uncertainty. Among different satellite sensors that can be used for soil moisture estimation three major groups can be distinguished: passive microwave sensors (e.g., SSMI), active sensors (e.g. SAR, Scatterometers), and optical sensors (e.g. Spectroradiometers). The last two families, mainly because of their temporal and spatial resolution seem the most suitable for hydrological applications In this work soil moisture point measurements from 10 sensors in the Italian territory are compared of with the satellite products both from the HSAF project SM-OBS-2, derived from the ASCAT scatterometer, and from ACHAB, an operative energy balance model that assimilate LST data derived from MSG and furnishes daily an evaporative fraction index related to soil moisture content for all the Italian region. Distributed comparison of the ACHAB and SM-OBS-2 on the whole Italian territory are performed too.

  19. Solid state semiconductor detectorized survey meter

    International Nuclear Information System (INIS)

    Okamoto, Eisuke; Nagase, Yoshiyuki; Furuhashi, Masato

    1987-01-01

    Survey meters are used for measurement of gamma ray dose rate of the space and the surface contamination dencity that the atomic energy plant and the radiation facility etc. We have recently developed semiconductor type survey meter (Commercial name: Compact Survey Meter). This survey meter is a small-sized dose rate meter with excellent function. The special features are using semiconductor type detector which we have developed by our own technique, stablar wide range than the old type, long life, and easy to carry. Now we introduce the efficiency and the function of the survey meter. (author)

  20. Density-independent algorithm for sensing moisture content of sawdust based on reflection measurements

    Science.gov (United States)

    A density-independent algorithm for moisture content determination in sawdust, based on a one-port reflection measurement technique is proposed for the first time. Performance of this algorithm is demonstrated through measurement of the dielectric properties of sawdust with an open-ended haft-mode s...

  1. Implementing a physical soil water flow model with minimal soil characteristics and added value offered by surface soil moisture measurements assimilation.

    Science.gov (United States)

    Chanzy, André

    2010-05-01

    Soil moisture is a key variable for many soil physical and biogeochemical processes. Its dynamic results from water fluxes in soil and at its boundaries, as well as soil water storage properties. If the water flows are dominated by diffusive processes, modelling approaches based on the Richard's equation or the Philip and de Vries coupled heat and water flow equations lead to a satisfactory representation of the soil moisture dynamic. However, It requires the characterization of soil hydraulic functions, the initialisation and the boundary conditions, which are expensive to obtain. The major problem to assess soil moisture for decision making or for representing its spatiotemporal evolution over complex landscape is therefore the lack of information to run the models. The aim of the presentation is to analyse how a soil moisture model can be implemented when only climatic data and basic soil information are available (soil texture, organic matter) and what would be the added of making a few soil moisture measurements. We considered the field scale, which is the key scale for decision making application (the field being the management unit for farming system) and landscape modelling (field size being comparable to the computation unit of distributed hydrological models). The presentation is limited to the bare soil case in order to limit the complexity of the system and the TEC model based on Philip and De Vries equations is used in this study. The following points are addressed: o the within field spatial variability. This spatial variability can be induced by the soil hydraulic properties and/or by the amount of infiltrated water induced by water rooting towards infiltration areas. We analyse how an effective parameterization of soil properties and boundary conditions can be used to simulate the field average moisture. o The model implementation with limited information. We propose strategies that can be implemented when information are limited to soil texture and

  2. Advanced Metering Infrastructure based on Smart Meters

    Science.gov (United States)

    Suzuki, Hiroshi

    By specifically designating penetrations rates of advanced meters and communication technologies, devices and systems, this paper introduces that the penetration of advanced metering is important for the future development of electric power system infrastructure. It examines the state of the technology and the economical benefits of advanced metering. One result of the survey is that advanced metering currently has a penetration of about six percent of total installed electric meters in the United States. Applications to the infrastructure differ by type of organization. Being integrated with emerging communication technologies, smart meters enable several kinds of features such as, not only automatic meter reading but also distribution management control, outage management, remote switching, etc.

  3. Isotopic composition of atmospheric moisture from pan water evaporation measurements.

    Science.gov (United States)

    Devi, Pooja; Jain, Ashok Kumar; Rao, M Someshwer; Kumar, Bhishm

    2015-01-01

    A continuous and reliable time series data of the stable isotopic composition of atmospheric moisture is an important requirement for the wider applicability of isotope mass balance methods in atmospheric and water balance studies. This requires routine sampling of atmospheric moisture by an appropriate technique and analysis of moisture for its isotopic composition. We have, therefore, used a much simpler method based on an isotope mass balance approach to derive the isotopic composition of atmospheric moisture using a class-A drying evaporation pan. We have carried out the study by collecting water samples from a class-A drying evaporation pan and also by collecting atmospheric moisture using the cryogenic trap method at the National Institute of Hydrology, Roorkee, India, during a pre-monsoon period. We compared the isotopic composition of atmospheric moisture obtained by using the class-A drying evaporation pan method with the cryogenic trap method. The results obtained from the evaporation pan water compare well with the cryogenic based method. Thus, the study establishes a cost-effective means of maintaining time series data of the isotopic composition of atmospheric moisture at meteorological observatories. The conclusions drawn in the present study are based on experiments conducted at Roorkee, India, and may be examined at other regions for its general applicability.

  4. Nuclear techniques for measuring moisture content in soil profiles

    International Nuclear Information System (INIS)

    Barrada, Y.

    1983-01-01

    The prevailing severe shortage of animal feed in most of the developing countries could, to a considerable extent, be overcome through improved range management, which includes introduction of high yielding drought-resistant forage crops, development of adequate water conservation measures, and as far as possible growing annual forage crops on part of the vast areas of arable land currently left fallow each year. Year round measurements are essential for a good understanding of soil water and nutrients dynamics, which allow for adequate evaluation of pasture management alternatives. The methods most commonly used for moisture measurements in soil profiles are discussed because such measurements are likely to form an essential part of any investigation aimed at increasing animal feed production through the development of adequate pasture management practices. (author)

  5. Investigation of the Interaction between Perovskite Films with Moisture via in Situ Electrical Resistance Measurement.

    Science.gov (United States)

    Hu, Long; Shao, Gang; Jiang, Tao; Li, Dengbing; Lv, Xinlin; Wang, Hongya; Liu, Xinsheng; Song, Haisheng; Tang, Jiang; Liu, Huan

    2015-11-18

    Organometal halide perovskites have recently emerged as outstanding semiconductors for solid-state optoelectronic devices. Their sensitivity to moisture is one of the biggest barriers to commercialization. In order to identify the effect of moisture in the degradation process, here we combined the in situ electrical resistance measurement with time-resolved X-ray diffraction analysis to investigate the interaction of CH3NH3PbI(3-x)Cl(x) perovskite films with moisture. Upon short-time exposure, the resistance of the perovskite films decreased and it could be fully recovered, which were ascribed to a mere chemisorption of water molecules, followed by the reversible hydration into CH3NH3PbI(3-x)Cl(x)·H2O. Upon long-time exposure, however, the resistance became irreversible due to the decomposition into PbI2. The results demonstrated the formation of monohydrated intermediate phase when the perovskites interacted with moisture. The role of moisture in accelerating the thermal degradation at 85 °C was also demonstrated. Furthermore, our study suggested that the perovskite films with fewer defects may be more inherently resistant to moisture.

  6. Measuring set: Reactor Power Meter (type of SG-8), Reactor Energy Meter (type of SG-11) and Digital Dose Meter (type of SG-9) for reactor rigs operation. Zestaw pomiarowy: miernik mocy reaktora (typ SG-8), miernik energii reaktora (typ SG-11) oraz cyfrowy miernik dawki (typ SG-9) dla potrzeb eksploatacji sond reaktorowych

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1982-01-01

    A measuring set consisting of the Reactor Power Meter, Reactor Energy Meter and Digital Dose Meter is described. The gamma radiation of water in the reactor primary cooling circuit reaches the ionisation chamber and involves the output current, driving the Reactor Power Meter and Reactor Energy Meter. The Digital Dose Meter is controlled by the output current of the self-powered detector mounted inside the reactor rig.

  7. Hardware Design of a Smart Meter

    OpenAIRE

    Ganiyu A. Ajenikoko; Anthony A. Olaomi

    2014-01-01

    Smart meters are electronic measurement devices used by utilities to communicate information for billing customers and operating their electric systems. This paper presents the hardware design of a smart meter. Sensing and circuit protection circuits are included in the design of the smart meter in which resistors are naturally a fundamental part of the electronic design. Smart meters provides a route for energy savings, real-time pricing, automated data collection and elimina...

  8. Calibration of a geophysically based model using soil moisture measurements in mountainous terrains

    Science.gov (United States)

    Pellet, Cécile; Hilbich, Christin; Marmy, Antoine; Hauck, Christian

    2016-04-01

    The use of geophysical methods in the field of permafrost research is well established and crucial since it is the only way to infer the composition of the subsurface material. Since geophysical measurements are indirect, ambiguities in the interpretation of the results can arise, hence the simultaneous use of several methods (e.g. electrical resistivity tomography and refraction seismics) is often necessary. The so-called four-phase model, 4PM (Hauck et al., 2011) constitutes a further step towards clarification of interpretation from geophysical measurements. It uses two well-known petrophysical relationships, namely Archie's law and an extension of Timur's time-averaged equation for seismic P-wave velocities, to quantitatively estimate the different phase contents (air, water and ice) in the ground from tomographic electric and seismic measurements. In this study, soil moisture measurements were used to calibrate the 4PM in order to assess the spatial distribution of water, ice and air content in the ground at three high elevation sites with different ground properties and thermal regimes. The datasets used here were collected as part of the SNF-project SOMOMOUNT. Within the framework of this project a network of six entirely automated soil moisture stations was installed in Switzerland along an altitudinal gradient ranging from 1'200 m. a.s.l. to 3'400 m. a.s.l. The standard instrumentation of each station comprises the installation of Frequency Domain Reflectometry (FDR) and Time Domain Reflectometry (TDR) sensors for long term monitoring coupled with repeated Electrical Resistivity Tomography (ERT) and Refraction Seismic Tomography (RST) as well as spatial FDR (S-FDR) measurements. The use of spatially distributed soil moisture data significantly improved the 4PM calibration process and a semi-automatic calibration scheme was developed. This procedure was then tested at three different locations, yielding satisfactory two dimensional distributions of water

  9. Flowing-water optical power meter for primary-standard, multi-kilowatt laser power measurements

    Science.gov (United States)

    Williams, P. A.; Hadler, J. A.; Cromer, C.; West, J.; Li, X.; Lehman, J. H.

    2018-06-01

    A primary-standard flowing-water optical power meter for measuring multi-kilowatt laser emission has been built and operated. The design and operational details of this primary standard are described, and a full uncertainty analysis is provided covering the measurement range from 1–10 kW with an expanded uncertainty of 1.2%. Validating measurements at 5 kW and 10 kW show agreement with other measurement techniques to within the measurement uncertainty. This work of the U.S. Government is not subject to U.S. copyright.

  10. Soil moisture mapping at Bubnow Wetland using L-band radiometer (ELBARA III)

    Science.gov (United States)

    Łukowski, Mateusz; Schwank, Mike; Szlązak, Radosław; Wiesmann, Andreas; Marczewski, Wojciech; Usowicz, Bogusław; Usowicz, Jerzy; Rojek, Edyta; Werner, Charles

    2016-04-01

    The study of soil moisture is a scientific challenge. Not only because of large diversity of soils and differences in their water content, but also due to the difficulty of measuring, especially in large scale. On this field of interest several methods to determine the content of water in soil exists. The basic and referential is gravimetric method, which is accurate, but suitable only for small spatial scales and time-consuming. Indirect methods are faster, but need to be validated, for example those based on dielectric properties of materials (e.g. time domain reflectometry - TDR) or made from distance (remote), like brightness temperature measurements. Remote sensing of soil moisture can be performed locally (from towers, drones, planes etc.) or globally (satellites). These techniques can complement and help to verify different models and assumptions. In our studies, we applied spatial statistics to local soil moisture mapping using ELBARA III (ESA L-band radiometer, 1.4 GHz) mounted on tower (6.5 meter height). Our measurements were carried out in natural Bubnow Wetland, near Polesie National Park (Eastern Poland), during spring time. This test-site had been selected because it is representative for one of the biggest wetlands in Europe (1400 km2), called "Western Polesie", localized in Ukraine, Poland and Belarus. We have investigated Bubnow for almost decade, using meteorological and soil moisture stations, conducting campaigns of hand-held measurements and collecting soil samples. Now, due to the possibility of rotation at different incidence angles (as in previous ELBARA systems) and the new azimuth tracking capabilities, we obtained brightness temperature data not only at different distances from the tower, but also around it, in footprints containing different vegetation and soil types. During experiment we collected data at area about 450 m2 by rotating ELBARA's antenna 5-175° in horizontal and 30-70° in vertical plane. This type of approach allows

  11. Sensitivity Enhancement of a PPM Level Capacitive Moisture Sensor

    Directory of Open Access Journals (Sweden)

    Lokesh Kumar

    2017-05-01

    Full Text Available Measurement of moisture at ppm or ppb level is very difficult and the fabrication of such sensors at low cost is always challenging. High sensitivity is an important parameter for trace level (ppm humidity sensors. Anelectronic detection circuit for interfacing the humidity sensor with high sensitivity requires a simple hardware circuit with few active devices. The recent trends for increasing the sensitivity include fabricating nanoporous film with a very large surface area. In the present work, the sensitivity of a parallel plate capacitive type sensor with metal oxide sensing film has been significantly improved with an aim to detect moisture from 3 to 100 ppm in the industrial process gases used to fabricate semiconductors and other sensitive electronic devices. The sensitivity has been increased by (i fabricating a nanoporous film of aluminum oxide using the sol-gel method and (ii increasing the cross-sectional area of a parallel plate capacitor. A novel double sided capacitive structure has been proposed where two capacitors have been fabricated—one on the top and one on the bottom side of a flat alumina substrate—and then the capacitors are connected in parallel. The structure has twice the sensitivity of a single sensor in the same ppm range but the size of the structure remains unchanged. The important characteristics of the sensors such as the sensitivity (S = Δ C Δ p p m × 100 , the response time (tr, and the recovery time (tc are determined and compared with a commercial SHAW, UKdew point meter. The fabricated double sided sensor has comparable sensitivity (S = 100%, tr (s = 28, tc (s = 40 with the commercial meter (S = 100.5%, tr (s = 258 but has a faster response time. The proposed method of sensitivity enhancement is simple, and mass producible.

  12. Automatic determination of moisture content in biofuels based on NIR-measurements; Automatisk fukthaltsbestaemning av biobraenslen med NIR-metoden

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Magnus; Wiklund, Sven Erik [AaF-Process AB, Stockholm (Sweden); Karlsson, Mikael; Tryzell, Robert [Bestwood AB, Sundbyberg (Sweden)

    2005-07-01

    The determination of moisture content of biofuel is of large importance for the energy sector. The used methods for moisture determination are based on fuels samples taken from the bulk followed by drying and weighing. To be able to instead determine the moisture content based on a method with good accuracy and with a short response time would be a large improvement. Both for the fuel sampling and the following analysis there are Swedish standards but concerning the fuel sampling the standards are often not followed. The main reason is the difficulties to sample fuel samples from different depth from a delivery. This is one of the reasons that some plants have installed mechanical samplers but the investment cost for these is relatively high. The aim of this project was to investigate the use of the NIR-method for automatic moisture determination in biofuels. Within the project the NIR-method was used to determine the moisture content on withdrawn fuel samples, in addition the possibility to integrate the NIR-method in an automatic sampling system is also described. A large number of samples, in total over 200 samples, have been evaluated with the NIR-method and compared with the reference method, oven drying and gravimetric determination of moisture content. That the NIR-method can be used to determine moisture content in a number of well defined materials have previously been shown. In this report it has moreover been shown that the method can be used under the conditions at the fuel delivery station and for a large spectrum of biofuels. The accuracy that can be achieved with the NIR-method is in the same magnitude as the standard method, i.e. the reference method used for the measurements. Altogether this shows that the NIR-method is an interesting alternative for integration in an automatic measurement system for determination of fuel moisture content in biofuels. To be able to use the NIR-method for automatic determination of fuel moisture content at the

  13. Moisture sources of the Mono Lake deglacial pluvial events

    Science.gov (United States)

    Wang, X.; Liang, M. C.; Ali, G.; Shen, C. C.; Cai, Y.; Ke, L.; Hemming, S. R.

    2016-12-01

    Enormously expanded lakes existed in the today's dry western US Great Basin during the last glacial period. The ancient shorelines located well above modern lake levels suggest that precipitation in lake basins must have been substantially higher in the past. It is however under debate whether the subtropical North Pacific or the tropical Pacific is the major moisture source that contributed to the pluvial events, particularly during the deglaciation. Here, we collected a suite of tufa carbonate samples deposited at the 2,080 meter terrace ( 135 meters above today's lake level) in the Mono Basin, California, a closed lake basin for the last 130 thousand years (kyr). At Goat Ranch, we discovered white, shiny, laminated botryoidal carbonate coatings on tufa mounds. Most of these coatings present two generations of formation separated by a hiatus, which indicates lake level fluctuations. Using high-precision U-Th dating techniques, we found that the lower layer was formed 14.1-14.4 kyr BP (corresponding to the North Atlantic Bølling warming period). The upper layer of the coating was formed 11.9-12.3 kyr BP (within the Younger Dryas event). We then obtained d18O, d13C, D47 and 17O-excess values for the two carbonate layers. The upper part is characterized by low d18O values, -8 to -12 ‰ VPDB, whereas the lower one has higher d18O values, -5 to -6 ‰ VPDB. Both share similar d13C values ( 1-2‰ VPDB). D47 analysis on the carbonates suggests that both layers were deposited in a water temperature of 9±2 oC (1s, n = 4 and 8, respectively). The two generations of carbonates present 17O-excess of moisture in values of 50±5 (1s, n=4) and 25±5 (1s, n=8) per meg VSMOW-SLAP, respectively. The large difference in 17O-excess of parent meteoric water points to different origins of moisture for the tufa carbonate formations. The high 17O-excess values during YD suggest a moisture source with a low relative humidity, consistent with the conventional view that the moisture

  14. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  15. Contributions of Precipitation and Soil Moisture Observations to the Skill of Soil Moisture Estimates in a Land Data Assimilation System

    Science.gov (United States)

    Reichle, Rolf H.; Liu, Qing; Bindlish, Rajat; Cosh, Michael H.; Crow, Wade T.; deJeu, Richard; DeLannoy, Gabrielle J. M.; Huffman, George J.; Jackson, Thomas J.

    2011-01-01

    The contributions of precipitation and soil moisture observations to the skill of soil moisture estimates from a land data assimilation system are assessed. Relative to baseline estimates from the Modern Era Retrospective-analysis for Research and Applications (MERRA), the study investigates soil moisture skill derived from (i) model forcing corrections based on large-scale, gauge- and satellite-based precipitation observations and (ii) assimilation of surface soil moisture retrievals from the Advanced Microwave Scanning Radiometer for the Earth Observing System (AMSR-E). Soil moisture skill is measured against in situ observations in the continental United States at 44 single-profile sites within the Soil Climate Analysis Network (SCAN) for which skillful AMSR-E retrievals are available and at four CalVal watersheds with high-quality distributed sensor networks that measure soil moisture at the scale of land model and satellite estimates. The average skill (in terms of the anomaly time series correlation coefficient R) of AMSR-E retrievals is R=0.39 versus SCAN and R=0.53 versus CalVal measurements. The skill of MERRA surface and root-zone soil moisture is R=0.42 and R=0.46, respectively, versus SCAN measurements, and MERRA surface moisture skill is R=0.56 versus CalVal measurements. Adding information from either precipitation observations or soil moisture retrievals increases surface soil moisture skill levels by IDDeltaR=0.06-0.08, and root zone soil moisture skill levels by DeltaR=0.05-0.07. Adding information from both sources increases surface soil moisture skill levels by DeltaR=0.13, and root zone soil moisture skill by DeltaR=0.11, demonstrating that precipitation corrections and assimilation of satellite soil moisture retrievals contribute similar and largely independent amounts of information.

  16. Measuring the spatial variation in surface moisture on a coastal beach with an infra-red terrestrial laser scanner

    Science.gov (United States)

    Smit, Yvonne; Donker, Jasper; Ruessink, Gerben

    2016-04-01

    Coastal sand dunes provide essential protection against marine flooding. Consequently, dune erosion during severe storms has been studied intensively, resulting in well-developed erosion models for use in scientific and applied projects. Nowadays there is growing awareness that similarly advanced knowledge on dune recovery and growth is needed to predict future dune development. For this reason, aeolian sand transport from the beach into the dunes has to be investigated thoroughly. Surface moisture is a major factor limiting aeolian transport on sandy beaches. By increasing the velocity threshold for sediment entrainment, pick-up rates reduce and the fetch length increases. Conventional measurement techniques cannot adequately characterize the spatial and temporal distribution of surface moisture content required to study the effects on aeolian transport. Here we present a new method for detecting surface moisture at high temporal and spatial resolution using the RIEGL VZ-400 terrestrial laser scanner (TLS). Because this TLS operates at a wavelength near a water absorption band (1550 nm), TLS reflectance is an accurate parameter to measure surface soil moisture over its full range. Three days of intensive laser scanning were performed on a Dutch beach to illustrate the applicability of the TLS. Gravimetric soil moisture samples were used to calibrate the relation between reflectance and surface moisture. Results reveal a robust negative relation for the full range of possible surface moisture contents (0% - 25%). This relation holds to about 80 m from the TLS. Within this distance the TLS typically produces O(106-107) data points, which we averaged into soil moisture maps with a 0.25x0.25 m resolution. This grid size largely removes small moisture disturbances induced by, for example, footprints or tire tracks, while retaining larger scale trends. As the next step in our research, we will analyze the obtained maps to determine which processes affect the spatial and

  17. Charge Meter

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 19; Issue 4. Charge Meter: Easy Way to Measure Charge and Capacitance: Some Interesting Electrostatic Experiments. M K Raghavendra V Venkataraman. Classroom Volume 19 Issue 4 April 2014 pp 376-390 ...

  18. Wanted: competitive metering infrastructure. Metering must be automated in a high grade; Gesucht: wettbewerbsfaehige Metering-Infrastruktur. Metering muss hochgradig automatisiert werden

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Elschner, C. [T-Systems Enterprise Services GmbH, Bonn (Germany). Business Development und Marketing

    2008-04-21

    Accurate on-time consumption metering and data transmission are increasingly important as energy markets are being deregulated. Measuring and information systems combine measurements with intelligent modules for automatic transmission of consumption information. A meaningful cost-benefit comparision results only when the total system is considered. Telecommunication companies as ICT service systems and service sectors can do a clear contribution to the total system. (orig./GL)

  19. A Technical Design Approach to Soil Moisture Content Measurement

    African Journals Online (AJOL)

    Soil moisture is an important type of data in many fields; ranging from agriculture to environmental monitoring. Three soil samples were collected at definite proportions to represent the three basic soil types (sandy, loamy and clay soils). The moisture contents of these soil samples were analyzed using the thermogravimetric ...

  20. Micrometeorological, evapotranspiration, and soil-moisture data at the Amargosa Desert Research site in Nye County near Beatty, Nevada, 2006-11

    Science.gov (United States)

    Arthur, Jonathan M.; Johnson, Michael J.; Mayers, C. Justin; Andraski, Brian J.

    2012-01-01

    This report describes micrometeorological, evapotranspiration, and soil-moisture data collected since 2006 at the Amargosa Desert Research Site adjacent to a low-level radio-active waste and hazardous chemical waste facility near Beatty, Nevada. Micrometeorological data include precipitation, solar radiation, net radiation, air temperature, relative humidity, saturated and ambient vapor pressure, wind speed and direction, barometric pressure, near-surface soil temperature, soil-heat flux, and soil-water content. Evapotranspiration (ET) data include latent-heat flux, sensible-heat flux, net radiation, soil-heat flux, soil temperature, air temperature, vapor pressure, and other principal energy-budget data. Soil-moisture data include periodic measurements of volumetric water-content at experimental sites that represent vegetated native soil, devegetated native soil, and simulated waste disposal trenches - maximum measurement depths range from 5.25 to 29.25 meters. All data are compiled in electronic spreadsheets that are included with this report.

  1. Effect of Initial Moisture on the Adsorption and Desorption Equilibrium Moisture Contents of Polished Rice

    OpenAIRE

    Murata, Satoshi; Amaratunga, K.S.P.; Tanaka, Fumihiko; Hori, Yoshiaki; 村田, 敏; 田中, 史彦; 堀, 善昭

    1993-01-01

    The moisture adsorption and desorption properties for polished rice have been measured using a dynamic ventilatory method. Air temperatures of 10,20,30 and 40℃, relative humidities of 50,60,70,80 and 90%, and five levels of initial moisture contents ranging approximately from 8% to 19% d.b. were used to obtain moisture content data. The value of equilibrium moisture content for each initial moisture content at the range of air condition was determined by a method of nonlinear least squares. R...

  2. Moisture distribution measurements in adhesive-bonded composites using the D (3He,p)4 He reaction

    International Nuclear Information System (INIS)

    Schulte, R.L.; Deiasi, R.J.

    1981-01-01

    Adhesive bonding of composite materials for many aircraft components offers a distinct advantage in weight and cost reduction compared to similar structures that have been joined by riveting. However, the long term performance of adhesive-bonded components depends on the degree and rate of moisture absorption by the adhesive in the service environment. To investigate the rate and the mechanism of water transport in adhesive-bonded composite materials, a nuclear reaction analysis method based on the D( 3 He,p) 4 He reaction is used to measure the moisture distributions. Samples of graphite/epoxy composite materials were bonded with an epoxy adhesive and isothermally conditioned in a controlled D 2 O environment at 70% relative humidity and 77 0 C for various exposure times. The moisture profiles were measured along the adhesive (adhesive scan) as well as through the thickness of the bonded joint (transverse scan). The dimensions of the probing beam were 125 μm x 125 μm for the adhesive scan and 25 μ x 200 μm for the transverse scan. Absolute deuterium concentrations were determined by comparison of the proton yield from the composite/adhesive to that from reference standards. Calculations from diffusion models of water transport based on parameters determined from bulk measurement techniques are compared to the measured profile and the agreement indicates that classical Fickian diffusion describes the transport of moisture in these materials

  3. Radioisotope conveyor ash meter

    International Nuclear Information System (INIS)

    Savelov, V.D.

    1994-01-01

    Radioisotope conveyor ash meter realizes persistent measuring of ashiness of coal and products of its enrichment on the belt conveyor without contact. The principle of ash meter acting is based on functional dependence of the gamma radiation flows backscattering intensity of radioisotope sources from the ash volume content in the controlled fuel. Facility consists from the ashiness transducer and the processing and control device

  4. Water velocity meter

    Science.gov (United States)

    Roberts, C. W.; Smith, D. L.

    1970-01-01

    Simple, inexpensive drag sphere velocity meter with a zero to 6 ft/sec range measures steady-state flow. When combined with appropriate data acquisition system, it is suited to applications where large numbers of simultaneous measurements are needed for current mapping or velocity profile determination.

  5. Design of Moisture Content Detection System

    Science.gov (United States)

    Wang, W. C.; Wang, L.

    In this paper, a method for measuring the moisture content of grain was presented based on single chip microcomputer and capacitive sensor. The working principle of measuring moisture content is introduced and a concentric cylinder type of capacitive sensor is designed, the signal processing circuits of system are described in details. System is tested in practice and discussions are made on the various factors affecting the capacitive measuring of grain moisture based on the practical experiments, experiment results showed that the system has high measuring accuracy and good controlling capacity.

  6. A gamma-source method of measuring soil moisture

    International Nuclear Information System (INIS)

    Al-Jeboori, M.A.; Ameen, I.A.

    1986-01-01

    Water content in soil column was measured using NaI scintillation detector 5 mci Cs-137 as a gamma source. The measurements were done with a back scatter gauge, restricted with scattering angle less to than /2 overcome the effect of soil type. A 3 cm air gap was maintained between the front of the detector and the wall of the soil container in order to increase the counting rate. The distance between the center of the source and the center of the back scattering detector was 14 cm. The accuracy of the measurements was 0.63. For comparision, a direct rays method was used to measure the soil moisture. The results gave an error of 0.65. Results of the two methods were compared with the gravimetric method which gave an error of 0.18 g/g and 0.17 g/g for direct and back method respectively. The quick direct method was used to determine the gravimetric and volumetric percentage constants, and were found to be 1.62 and 0.865 respectively. The method then used to measure the water content in the layers of soil column.(6 tabs., 4 figs., 12 refs.)

  7. Two-channel neutron boron meter

    International Nuclear Information System (INIS)

    Chen Yongqing; Yin Guowei; Chai Songshan; Deng Zhaoping; Zhou Bin

    1993-09-01

    The two-channel neutron boron meter is a continuous on-line measuring device to measure boron concentration of primary cooling liquid of reactors. The neutron-leakage-compensation method is taken in the measuring mechanism. In the primary measuring configuration, the mini-boron-water annulus and two-channel and central calibration loop are adopted. The calibration ring and constant-temperature of boron-water can be remotely controlled by secondary instruments. With the microcomputer data processing system the boron concentration is automatically measured and calibrated in on-line mode. The meter has many advantages such as high accuracy, fast response, multi-applications, high reliability and convenience

  8. Monitoring hillslope moisture dynamics with surface ERT for enhancing spatial significance of hydrometric point measurements

    Science.gov (United States)

    Hübner, R.; Heller, K.; Günther, T.; Kleber, A.

    2015-01-01

    Besides floodplains, hillslopes are basic units that mainly control water movement and flow pathways within catchments of subdued mountain ranges. The structure of their shallow subsurface affects water balance, e.g. infiltration, retention, and runoff. Nevertheless, there is still a gap in the knowledge of the hydrological dynamics on hillslopes, notably due to the lack of generalization and transferability. This study presents a robust multi-method framework of electrical resistivity tomography (ERT) in addition to hydrometric point measurements, transferring hydrometric data into higher spatial scales to obtain additional patterns of distribution and dynamics of soil moisture on a hillslope. A geoelectrical monitoring in a small catchment in the eastern Ore Mountains was carried out at weekly intervals from May to December 2008 to image seasonal moisture dynamics on the hillslope scale. To link water content and electrical resistivity, the parameters of Archie's law were determined using different core samples. To optimize inversion parameters and methods, the derived spatial and temporal water content distribution was compared to tensiometer data. The results from ERT measurements show a strong correlation with the hydrometric data. The response is congruent to the soil tension data. Water content calculated from the ERT profile shows similar variations as that of water content from soil moisture sensors. Consequently, soil moisture dynamics on the hillslope scale may be determined not only by expensive invasive punctual hydrometric measurements, but also by minimally invasive time-lapse ERT, provided that pedo-/petrophysical relationships are known. Since ERT integrates larger spatial scales, a combination with hydrometric point measurements improves the understanding of the ongoing hydrological processes and better suits identification of heterogeneities.

  9. Radiofrequency energy exposure from the Trilliant smart meter.

    Science.gov (United States)

    Foster, Kenneth R; Tell, Richard A

    2013-08-01

    This paper reviews radiofrequency (RF) field levels produced by electric utility meters equipped with RF transceivers (so-called Smart Meters), focusing on meters from one manufacturer (Trilliant, Redwood City, CA, USA, and Granby, QC, Canada). The RF transmission levels are summarized based on publicly available data submitted to the U.S. Federal Communications Commission supplemented by limited independent measurements. As with other Smart Meters, this meter incorporates a low powered radiofrequency transceiver used for a neighborhood mesh network, in the present case using ZigBee-compliant physical and medium access layers, operating in the 2.45 GHz unlicensed band but with a proprietary network architecture. Simple calculations based on a free space propagation model indicate that peak RF field intensities are in the range of 10 mW m or less at a distance of more than 1-2 m from the meters. However, the duty cycle of transmission from the meters is very low (meter that were consistent with data reported by the vendor to the U.S. Federal Communications Commission. Limited measurements conducted in two houses with the meters were unable to clearly distinguish emissions from the meters from the considerable electromagnetic clutter in the same frequency range from other sources, including Wi-Fi routers and, when it was activated, a microwave oven. These preliminary measurements disclosed the difficulties that would be encountered in characterizing the RF exposures from these meters in homes in the face of background signals from other household devices in the same frequency range. An appendix provides an introduction to Smart Meter technology. The RF transmitters in wireless-equipped Smart Meters operate at similar power levels and in similar frequency ranges as many other digital communications devices in common use, and their exposure levels are very far below U.S. and international exposure limits.

  10. Microcomputerized neutron moisture gauge

    International Nuclear Information System (INIS)

    Liu Shengkang; Mei Yu

    1987-01-01

    A microcomputerized neutron moisture gauge is introduced. This gauge consists of a neutron moisture sensor and instruments. It is developed from the neutron moisture gauge for concrete mixer. A TECH-81 single card microcomputer is used for count, computation and display. It has the function of computing compensated quantity of sand. It can acquire the data from several neutron sensors by the multichanneling sampling, therefore it can measure moisture values of sand in several hoppers simultaneously. The precision of the static state calibration curve is 0.24% wt. The error limits of the dynamic state check is < 0.50% wt

  11. Arduino based radiation survey meter

    International Nuclear Information System (INIS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee; Muzakkir, Amir

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr −1 ). Conversion factor (CF) value for conversion of CPM to μSvhr −1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr

  12. Balanced Flow Meters without Moving Parts

    Science.gov (United States)

    Kelley, Anthony R.; VanBuskirk, Paul

    2008-01-01

    Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced

  13. Streamlining Smart Meter Data Analytics

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2015-01-01

    of the so-called big data possible. This can improve energy management, e.g., help utilities improve the management of energy and services, and help customers save money. As this regard, the paper focuses on building an innovative software solution to streamline smart meter data analytic, aiming at dealing......Today smart meters are increasingly used in worldwide. Smart meters are the advanced meters capable of measuring customer energy consumption at a fine-grained time interval, e.g., every 15 minutes. The data are very sizable, and might be from different sources, along with the other social......-economic metrics such as the geographic information of meters, the information about users and their property, geographic location and others, which make the data management very complex. On the other hand, data-mining and the emerging cloud computing technologies make the collection, management, and analysis...

  14. Feasibility study of prompt gamma neutron activation for NDT measurement of moisture in stone and brick

    Energy Technology Data Exchange (ETDEWEB)

    Livingston, R. A.; Al-Sheikhly, M. [Materials Science and Engineering Dept., U. of Maryland, College Park MD 20742 (United States); Grissom, C.; Aloiz, E. [Museum Conservation Institute, Smithsonian Institution, Washington DC 20746 (United States); Paul, R. [Chemical Sciences Division, NIST, Gaithersburg MD 20899 (United States)

    2014-02-18

    The conservation of stone and brick architecture or sculpture often involves damage caused by moisture. The feasibility of a NDT method based on prompt gamma neutron activation (PGNA) for measuring the element hydrogen as an indication of water is being evaluated. This includes systematic characterization of the lithology and physical properties of seven building stones and one brick type used in the buildings of the Smithsonian Institution in Washington, D.C. To determine the required dynamic range of the NDT method, moisture-related properties were measured by standard methods. Cold neutron PGNA was also used to determine chemically bound water (CBW) content. The CBW does not damage porous masonry, but creates an H background that defines the minimum level of detection of damaging moisture. The CBW was on the order of 0.5% for all the stones. This rules out the measurement of hygric processes in all of the stones and hydric processed for the stones with fine scale pore-size distributions The upper bound of moisture content, set by porosity through water immersion, was on the order of 5%. The dynamic range is about 10–20. The H count rates were roughly 1–3 cps. Taking into account differences in neutron energies and fluxes and sample volume between cold PGNA and a portable PGNA instrument, it appears that it is feasible to apply PGNA in the field.

  15. Heat and Moisture transport of socks

    Science.gov (United States)

    Komárková, P.; Glombíková, V.; Havelka, A.

    2017-10-01

    Investigating the liquid moisture transport and thermal properties is essential for understanding physiological comfort of clothes. This study reports on an experimental investigation of moisture management transport and thermal transport on the physiological comfort of commercially available socks. There are subjective evaluation and objective measurements. Subjective evaluation of the physiological comfort of socks is based on individual sensory perception of probands during and after physical exertion. Objective measurements were performed according to standardized methods using Moisture Management tester for measuring the humidity parameters and C-term TCi analyzer for thermal conductivity and thermal effusivity. The obtained values of liquid moisture transport and thermal properties were related to the material composition and structure of the tested socks. In summary, these results show that objective measurement corresponds with probands feelings.

  16. Background radiation measurements at 400 meter underground for dark matter search study

    International Nuclear Information System (INIS)

    Kim, T. Y.; Kim, H. J.; Lee, Y. C.; Won, E.; Kim, S. K.; Kim, Y. D.; So, W. Y.

    1999-01-01

    Recently we have performed measurements of background radiation, which is crucial for any dark matter search experiments. We measured muons, neutrons, and gamma backgrounds at approximately 400 meter underground tunnel in the electric generating facility located about 120 km east of Seoul. We believe this may be the first measurement at this depth in Korea. The muon flux measured with triple coincidence between 3 scintillating plates was reduced by a factor of 10 4 compared with the flux at ground level as expected at this depth. The unshielded gamma background measured with 15% relative efficiency germanium detector was rather high due to the surrounding rocks. Shielded with 15 cm normal lead and 2.5 cm electrode copper gave about 0.5 counts/second. (author)

  17. A system for measuring moisture transients in clay-based barrier materials

    International Nuclear Information System (INIS)

    Wan, A.W.L.; Kjartanson, B.H.; Spinney, M.H.; Radhakrishna, H.S.; Lau, K.C.

    1992-01-01

    This paper discusses the Buffer/Container Experiment which is one of the large-scale insitu experiments being conducted by AECL Research at its Underground Research Laboratory. The experiment is intended to examine the thermal-hydraulic-mechanical performance of sand-bentonite buffer material in a single emplacement borehole arrangement under in situ boundary conditions. Thermocouple psychrometers and thermal needles are being used as moisture sensors to track moisture transients in the buffer as the experiment progresses. Excitation and logging of the moisture sensors are largely automated. Procedures are being implemented to provide full automation of the moisture sensor system and to facilitate data conversion and management. Preliminary results from the Buffer/Container Experiment show that, up to five months after installation, the majority of the moisture sensors continue to function reliably

  18. Multi-channel ground-penetrating radar to explore spatial variations in thaw depth and moisture content in the active layer of a permafrost site

    Directory of Open Access Journals (Sweden)

    U. Wollschläger

    2010-08-01

    Full Text Available Multi-channel ground-penetrating radar (GPR was applied at a permafrost site on the Tibetan Plateau to investigate the influence of surface properties and soil texture on the late-summer thaw depth and average soil moisture content of the active layer. Measurements were conducted on an approximately 85 × 60 m2 sized area with surface and soil textural properties that ranged from medium to coarse textured bare soil to finer textured, sparsely vegetated areas covered with fine, wind blown sand, and it included the bed of a gravel road. The survey allowed a clear differentiation of the various units. It showed (i a shallow thaw depth and low average soil moisture content below the sand-covered, vegetated area, (ii an intermediate thaw depth and high average soil moisture content along the gravel road, and (iii an intermediate to deep thaw depth and low to intermediate average soil moisture content in the bare soil terrain. From our measurements, we found hypotheses for the permafrost processes at this site leading to the observed late-summer thaw depth and soil moisture conditions. The study clearly indicates the complicated interactions between surface and subsurface state variables and processes in this environment. Multi-channel GPR is an operational technology to efficiently study such a system at scales varying from a few meters to a few kilometers.

  19. Evaluation of free water and water activity measurements as functional alternatives to total moisture content in broiler excreta and litter samples.

    Science.gov (United States)

    van der Hoeven-Hangoor, E; Rademaker, C J; Paton, N D; Verstegen, M W A; Hendriks, W H

    2014-07-01

    Litter moisture contents vary greatly between and within practical poultry barns. The current experiment was designed to measure the effects of 8 different dietary characteristics on litter and excreta moisture content. Additionally, free water content and water activity of the excreta and litter were evaluated as additional quality measures. The dietary treatments consisted of nonstarch polysaccharide content (NSP; corn vs. wheat), particle size of insoluble fiber (coarse vs. finely ground oat hulls), viscosity of a nonfermentable fiber (low- and high-viscosity carboxymethyl cellulose), inclusion of a clay mineral (sepiolite), and inclusion of a laxative electrolyte (MgSO4). The 8 treatments were randomly assigned to cages within blocks, resulting in 12 replicates per treatment with 6 birds per replicate. Limited effects of the dietary treatments were noted on excreta and litter water activity, and indications were observed that this measurement is limited in high-moisture samples. Increasing dietary NSP content by feeding a corn-based diet (low NSP) compared with a wheat-based diet (high NSP) increased water intake, excreta moisture and free water, and litter moisture content. Adding insoluble fibers to the wheat-based diet reduced excreta and litter moisture content, as well as litter water activity. Fine grinding of the oat hulls diminished the effect on litter moisture and water activity. However, excreta moisture and free water content were similar when fed finely or coarsely ground oat hulls. The effects of changing viscosity and adding a clay mineral or laxative deviated from results observed in previous studies. Findings of the current experiment indicate a potential for excreta free water measurement as an additional parameter to assess excreta quality besides total moisture. The exact implication of this parameter warrants further investigation. © 2014 Poultry Science Association Inc.

  20. Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Mort, Dan [ADM Associates, Inc. Sacramento, CA (United States)

    2017-09-01

    Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.

  1. Multiphase flow metering: 4 years on

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, G.; Hewitt, G.F.; Alimonti, C.; Harrison, B.

    2005-07-01

    Since the authors' last review in 2001 [1], the use of Multiphase Flow Metering (MFM) within the oil and gas industry continues to grow apace, being more popular in some parts of the world than others. Since the early 1990's, when the first commercial meters started to appear, there have been more than 1,600 field applications of MFM for field allocation, production optimisation and mobile well testing. As the authors predicted, wet gas metering technology has improved to such an extent that its use has rapidly increased worldwide. A ''who's who'' of the MFM sector is provided, which highlights the mergers in the sector and gives an insight into the meters and measurement principles available today. Cost estimates, potential benefits and reliability in the field of the current MFM technologies are revisited and brought up to date. Several measurements technologies have resurfaced, such as passive acoustic energy patterns, infrared wavelengths, Nuclear Magnetic Resonance (NMR) and Electrical Capacitance Tomography (ECT), and they are becoming commercial. The concept of ''virtual metering'', integrated with ''classical MFM'', is now widely accepted. However, sometimes the principles of the MFM measurements themselves are forgotten, submerged in the sales and marketing hype. (author) (tk)

  2. Calibration of ionization chamber and GM counter survey meters, (1)

    International Nuclear Information System (INIS)

    Bingo, Kazuyoshi; Kajimoto, Yoichi; Suga, Shin-ichi

    1978-01-01

    Three types of ionization chamber survey meters and a type of GM counter survey meter were calibrated for measuring the β-ray absorbed dose rate in a working area. To estimate the β-ray absorbed dose rate, a survey meter was used without and with a filter. A reading of survey meter's indicator measured with the filter was subtracted from a reading measured without the filter, and then the absorbed dose rate was obtained by multiplying this remainder by a conversion coefficient. The conversion coefficients were roughly constant with distance more than 8 cm (ionization chamber survey meters) and with distance more than 5 cm (GM counter survey meter). The conversion coefficient was dependent on β-ray energies. In order to measure the absorbed dose rate of tissue whose epidermal thickness is 40 mg/cm 2 , the constant value, 4 (mrad/h)/(mR/h), was chosen independently of β-ray energies as the conversion coefficient of three types of ionization chamber survey meters. The conversion coefficient of the GM counter survey meter was more energy dependent than that of every type of ionization chamber survey meter. (author)

  3. Liquid metal Flow Meter - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.; Hoogendoom, S.; Hudson, B.; Prince, J.; Teichert, K.; Wood, J.; Chase, K.

    2007-01-30

    Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

  4. Turbine flow meter response in two-phase flows

    International Nuclear Information System (INIS)

    Shim, W.J.; Dougherty, T.J.; Cheh, H.Y.

    1996-01-01

    The purpose of this paper is to suggest a simple method of calibrating turbine flow meters to measure the flow rates of each phase in a two-phase flow. The response of two 50.8 mm (2 inch) turbine flow meters to air-water, two-phase mixtures flowing vertically in a 57 mm I.D. (2.25 inch) polycarbonate tube has been investigated for both upflow and downflow. The flow meters were connected in series with an intervening valve to provide an adjustable pressure difference between them. Void fractions were measured by two gamma densitometers, one upstream of the flow meters and the other downstream. The output signal of the turbine flow meters was found to depend only on the actual volumetric flow rate of the gas, F G , and liquid, F L , at the location of the flow meter

  5. Neutron measurement in 12,13C+ 27Al system using CR-39 detectors and neutron rem meter

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Shanbhag, A.A.; Sunil, C.; Joshi, D.S.; Sarkar, P.K.

    2011-01-01

    In this work, neutron measurements carried out for the interaction of 60 and 67.5 MeV 12 C, 57.3 and 65 MeV 13 C ions with thick aluminium target by using CR-39 detectors and neutron rem meter is reported. Both the detector systems were irradiated at different angles viz. 0 deg, 30 deg, 60 deg, 90 deg with respect to the beam direction. The normalized track density measurements (tracks/cm 2 /projectile at 1m) in CR-39 detectors were correlated with the normalized dose equivalent values (μSv/projectile at 1m) obtained using the neutron rem meter. The track density was found to be more in case of 13 C than 12 C. However in all the cases, the track density per incident projectile was found to decrease as the angle with respect to beam direction increases, indicating non-isotropic nature of neutron emission. The ratio between measured dose equivalent in rem meter to the measured track densities in CR-39 detectors was found to be 2.8±0.2, which remains constant irrespective of the change in angle from beam direction as well as neutron spectrum, indicating a flat dose response of CR-39 detectors. (author)

  6. Arduino based radiation survey meter

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee [Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Muzakkir, Amir [Sinaran Utama Teknologi Sdn Bhd, 43650, Bandar Baru Bangi, Selangor (Malaysia)

    2016-01-22

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  7. Multiscale soil moisture estimates using static and roving cosmic-ray soil moisture sensors

    Science.gov (United States)

    McJannet, David; Hawdon, Aaron; Baker, Brett; Renzullo, Luigi; Searle, Ross

    2017-12-01

    Soil moisture plays a critical role in land surface processes and as such there has been a recent increase in the number and resolution of satellite soil moisture observations and the development of land surface process models with ever increasing resolution. Despite these developments, validation and calibration of these products has been limited because of a lack of observations on corresponding scales. A recently developed mobile soil moisture monitoring platform, known as the rover, offers opportunities to overcome this scale issue. This paper describes methods, results and testing of soil moisture estimates produced using rover surveys on a range of scales that are commensurate with model and satellite retrievals. Our investigation involved static cosmic-ray neutron sensors and rover surveys across both broad (36 × 36 km at 9 km resolution) and intensive (10 × 10 km at 1 km resolution) scales in a cropping district in the Mallee region of Victoria, Australia. We describe approaches for converting rover survey neutron counts to soil moisture and discuss the factors controlling soil moisture variability. We use independent gravimetric and modelled soil moisture estimates collected across both space and time to validate rover soil moisture products. Measurements revealed that temporal patterns in soil moisture were preserved through time and regression modelling approaches were utilised to produce time series of property-scale soil moisture which may also have applications in calibration and validation studies or local farm management. Intensive-scale rover surveys produced reliable soil moisture estimates at 1 km resolution while broad-scale surveys produced soil moisture estimates at 9 km resolution. We conclude that the multiscale soil moisture products produced in this study are well suited to future analysis of satellite soil moisture retrievals and finer-scale soil moisture models.

  8. Calibration Curve of Neutron Moisture Meter for Sandy Soil under Drip Irrigation System

    International Nuclear Information System (INIS)

    Mohammad, Abd El- Moniem M.; Gendy, R. W.; Bedaiwy, M. N.

    2004-01-01

    The aim of this work is to construct a neutron calibration curve in order to be able to use the neutron probe in sandy soils under drip irrigation systems. The experimental work was conducted at the Soil and Water Department of the Nuclear Research Center, Atomic Energy Authority. Three replicates were used along the lateral lines of the drip irrigation system. For each dripper, ten neutron access tubes were installed to 100-cm depth at distances of 5, 15 and 25 cm from the dripper location around the drippers on the lateral line, as well as between lateral lines. The neutron calibrations were determined at 30, 45, and 60-cm depths. Determining coefficients as well as t-test in pairs were employed to detect the accuracy of the calibrations. Results indicated that in order for the neutron calibration curve to express the whole wet area around the emitter; three-access tubes must be installed at distances of 5, 15, and 25 cm from the emitter. This calibration curve will be correlating the average count ratio (CR) at the studied soil depth of the three locations (5, 15, and 25-cm distances from the emitter) to the average moisture content (θ) for this soil depth of the entire wetted area. This procedure should be repeated at different times in order to obtain different θ and C.R values, so that the regression equation of calibration curve at this soil depth can be obtained. To determine the soil moisture content, the average CR of the three locations must be taken and substituted into the regression equation representing the neutron calibration curve. Results taken from access tubes placed at distances of 15 cm from the emitter, showed good agreement with the average calibration curve both for the 45- and the 60-cm depths, suggesting that the 15-cm distance may provide a suitable substitute for the simultaneous use of the three different distances of 5, 15 and 25 cm. However, the obtained results show also that the neutron calibration curves of the 30-cm depth for

  9. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.

    Science.gov (United States)

    Malusek, A; Helmrot, E; Sandborg, M; Grindborg, J-E; Carlsson, G Alm

    2014-12-07

    The air kerma-area product (KAP) is used for settings of diagnostic reference levels. The International Atomic Energy Agency (IAEA) recommends that doses in diagnostic radiology (including the KAP values) be estimated with an accuracy of at least ± 7% (k = 2). Industry standards defined by the International Electrotechnical Commission (IEC) specify that the uncertainty of KAP meter measurements should be less than ± 25% (k = 2). Medical physicists willing to comply with the IAEA's recommendation need to apply correction factors to KAP values reported by x-ray units. The aim of this work is to present and evaluate a calibration method for built-in KAP meters on clinical x-ray units. The method is based on (i) a tandem calibration method, which uses a reference KAP meter calibrated to measure the incident radiation, (ii) measurements using an energy-independent ionization chamber to correct for the energy dependence of the reference KAP meter, and (iii) Monte Carlo simulations of the beam quality correction factors that correct for differences between beam qualities at a standard laboratory and the clinic. The method was applied to the KAP meter in a Siemens Aristos FX plus unit. It was found that values reported by the built-in KAP meter differed from the more accurate values measured by the reference KAP meter by more than 25% for high tube voltages (more than 140 kV) and heavily filtered beams (0.3 mm Cu). Associated uncertainties were too high to claim that the IEC's limit of 25% was exceeded. Nevertheless the differences were high enough to justify the need for a more accurate calibration of built-in KAP meters.

  10. Monitoring of prestressed concrete pressure vessels. II. performance of selected concrete embedment strain meters under normal and extreme environmental conditions

    International Nuclear Information System (INIS)

    Naus, D.J.; Hurtt, C.C.

    1978-10-01

    Unique types of instrumentation are used in prestressed concrete pressure vessels (PCPVs) to measure strains, stresses, deflections, prestressing forces, moisture content, temperatures, and possibly cracking. Their primary purpose is to monitor these complex structures throughout their 20- to 30-year operating lifetime in order to provide continuing assurance of their reliability and safety. Numerous concrete embedment instrumentation systems are available commercially. Since this instrumentation is important in providing continuing assurance of satisfactory performance of PCPVs, the information provided must be reliable. Therefore, laboratory studies were conducted to evaluate the reliability of these commercially available instrumentation systems. This report, the second in a series related to instrumentation embedded in concrete, presents performance-reliability data for 13 types of selected concrete embedment strain meters which were subjected to a variety of loading environments, including unloaded, thermally loaded, simulated PCPV, and extreme environments. Although only a limited number of meters of each type were tested in any one test series, the composite results of the investigation indicate that the majority of these meters would not be able to provide reliable data throughout the 20- to 30-year anticipated operating life of a PCPV. Specific conclusions drawn from the study are: (1) Improved corrosion-resistant materials and sealing techniques should be developed for meters that are to be used in PCPV environments. (2) There is a need for the development of meters that are capable of surviving in concretes where temperatures in excess of 66 0 C are present for extended periods of time. (3) Research should be conducted on other measurement techniques, such as inductance, capacitance, and fluidics

  11. Humidity measurements in the precast concrete

    International Nuclear Information System (INIS)

    Hurez, M.

    1986-01-01

    The precast concrete industry manufactures requires a good knowledge and control of the humidity factor: during the manufacturing process, in order to regulate the water content of aggregates, or the fresh concrete workability: during the quality control of the product characteristics. The principles of measurements: conductivity, dielectric characteristics and neutron moisture meters are compared for cost, humidity range, accuracy, temperature dependence, interfering elements, density dependence, grain size and shape [fr

  12. Characterization of the analytic performance of an electrochemical point-of-care meter for measuring β-hydroxybutyrate concentration in blood and plasma from periparturient dairy cattle.

    Science.gov (United States)

    Megahed, Ameer A; Hiew, Mark W H; Townsend, Jonathan R; Constable, Peter D

    2017-06-01

    The Precision Xtra electrochemical meter is widely used to measure blood β-hydroxybutyrate concentration (BHBb) in dairy cattle. The meter uses an algorithm optimized for human blood that assumes the HCT in cattle is the same as in people, and that intra-erythrocyte β-hydroxybutyrate (BHBe) and plasma β-hydroxybutyrate (BHBp) concentration are equivalent. The first objective was to characterize the analytic performance of the meter for measuring BHBb and BHBp in dairy cattle. The second objective was to characterize the influence of HCT and sample temperature on BHBp concentration measured by the meter. Blood and plasma samples were obtained from 106 periparturient Holstein cattle and 15 lactating Holstein cows with experimentally induced electrolyte and acid-base imbalances. Meter performance was evaluated using Deming regression and Bland-Altman plots. Multivariable linear regression was used to determine the effect of HCT and sample temperature on BHBb and BHBp concentration, respectively. The meter was linear up to BHB = 3.0 mmol/L as measured by the reference method, equivalent to meter values for BHBb > 4.5 mmol/L and BHBp > 5.2 mmol/L. An increase in HCT resulted in higher BHBb concentration. This result was partially explained by BHBe being much lower than BHBp. Changes in sample temperature caused a linear change in measured BHBp whenever BHBp > 3.0 mmol/L. Meter accuracy was markedly dependent on the BHBe-to-BHBp ratio and consequently the HCT. Therefore, the algorithm used by the meter should be revised when applied to bovine blood for improved accuracy. © 2017 American Society for Veterinary Clinical Pathology.

  13. Spectrally adjustable quasi-monochromatic radiance source based on LEDs and its application for measuring spectral responsivity of a luminance meter

    International Nuclear Information System (INIS)

    Hirvonen, Juha-Matti; Poikonen, Tuomas; Vaskuri, Anna; Kärhä, Petri; Ikonen, Erkki

    2013-01-01

    A spectrally adjustable radiance source based on light-emitting diodes (LEDs) has been constructed for spectral responsivity measurements of radiance and luminance meters. A 300 mm integrating sphere source with adjustable output port is illuminated using 30 thermally stabilized narrow-band LEDs covering the visible wavelength range of 380–780 nm. The functionality of the measurement setup is demonstrated by measuring the relative spectral responsivities of a luminance meter and a photometer head with cosine-corrected input optics. (paper)

  14. Two laboratory methods for the calibration of GPS speed meters

    International Nuclear Information System (INIS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40–180 km h −1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology. (paper)

  15. Retrieving moisture profiles from precipitable water measurements using a variational data assimilation approach

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Y.R.; Zou, X.; Kuo, Y.H. [National Center for Atmospheric Research, Boulder, CO (United States)

    1996-04-01

    Atmospheric moisture distribution is directly related to the formation of clouds and precipitation and affects the atmospheric radiation and climate. Currently, several remote sensing systems can measure precipitable water (PW) with fairly high accuracy. As part of the development of an Integrated Data Assimilation and Sounding System in support of the Atmospheric Radiation Measurement Program, retrieving the 3-D water vapor fields from PW measurements is an important problem. A new four dimensional variational (4DVAR) data assimilation system based on the Penn State/National Center for Atmospheric Research (NCAR) mesoscale model (MM5) has been developed by Zou et al. (1995) with the adjoint technique. In this study, we used this 4DVAR system to retrieve the moisture profiles. Because we do not have a set of real observed PW measurements now, the special soundings collected during the Severe Environmental Storm and Mesoscale Experiment (SESAME) in 1979 were used to simulate a set of PW measurements, which were then assimilated into the 4DVAR system. The accuracy of the derived water vapor fields was assessed by direct comparison with the detailed specific humidity soundings. The impact of PW assimilation on precipitation forecast was examined by conducting a series of model forecast experiments started from the different initial conditions with or without data assimilation.

  16. Reactor core flow measurements during plant start-up using non-intrusive flow meter CROSSFLOW

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, V.; Sharp, B.; Gurevich, A., E-mail: vkanda@amag-inc.com, E-mail: bsharp@amag-inc.com, E-mail: agurevich@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada); Gurevich, Y., E-mail: yuri.gurevich@daystartech.ca [Daystar Technologies Inc., Ontario (Canada); Selvaratnarajah, S.; Lopez, A., E-mail: sselvaratnarajah@amag-inc.com, E-mail: alopez@amag-inc.com [Advanced Measurement & Analysis Group Inc., Ontario (Canada)

    2013-07-01

    For the first time, direct measurements of the total reactor coolant flow and the flow distribution between the inner reactor zone and the outer zone were conducted using the non-intrusive clamp on ultrasonic cross-correlation flow meter, CROSSFLOW, developed and manufactured by Advanced Measurement & Analysis Group Inc. (AMAG). The measurements were performed at Bruce Power A Unit 1 on the Pump Discharge piping of the Primary Heat Transport (PHT) system during start-up. This paper describes installation processes, hydraulic testing, uncertainty analysis and traceability of the measurements to certified standards. (author)

  17. Proceedings of the 66th National Conference on Weights and Measures, 1981

    Science.gov (United States)

    Wollin, H. F.; Barbrow, L. E.; Heffernan, A. P.

    1981-12-01

    Major issues discussed included measurement science education, enforcement uniformly, national type approval, inch pound and metric labeling provisions, new design and performance requirements for weighing and measuring technology, metric conversion of retail gasoline dispensers, weights and measures program evaluation studies of model State laws and regulations and their adoption by citation or other means by State and local jurisdictions, and report of States conducting grain moisture meter testing programs.

  18. Blending Satellite Observed, Model Simulated, and in Situ Measured Soil Moisture over Tibetan Plateau

    Directory of Open Access Journals (Sweden)

    Yijian Zeng

    2016-03-01

    Full Text Available The inter-comparison of different soil moisture (SM products over the Tibetan Plateau (TP reveals the inconsistency among different SM products, when compared to in situ measurement. It highlights the need to constrain the model simulated SM with the in situ measured data climatology. In this study, the in situ soil moisture networks, combined with the classification of climate zones over the TP, were used to produce the in situ measured SM climatology at the plateau scale. The generated TP scale in situ SM climatology was then used to scale the model-simulated SM data, which was subsequently used to scale the SM satellite observations. The climatology-scaled satellite and model-simulated SM were then blended objectively, by applying the triple collocation and least squares method. The final blended SM can replicate the SM dynamics across different climatic zones, from sub-humid regions to semi-arid and arid regions over the TP. This demonstrates the need to constrain the model-simulated SM estimates with the in situ measurements before their further applications in scaling climatology of SM satellite products.

  19. Moisture accumulation in a building envelope

    Energy Technology Data Exchange (ETDEWEB)

    Forest, T.W.; Checkwitch, K.

    1988-09-01

    In a large number of cases, the failure of a building envelope can be traced to the accumulation of moisture. In a cold winter climate, characteristic of the Canadian prairies, moisture is deposited in the structure by the movement of warm, moist air through the envelope. Tests on the moisture accumulation in a building envelope were initiated in a test house at an Alberta research facility during the 1987/88 heating season. The indoor moisture generation rate was measured and compared with the value inferred from the measured air infiltration rate. With the flue open, the moisture generation rate was approximately 5.5 kg/d of which 0.7 kg/d entered the building envelope; the remainder was exhausted through the flue. With the flue blocked, the moisture generation rate decreased to 3.4 kg/d, while the amount of moisture migrating through the envelope increased to 4.0 kg/d. The moisture accumulation in wall panels located on the north and south face of the test house was also monitored. Moisture was allowed to enter the wall cavity via a hole in the drywall. The fiberglass insulation remained dry throughout the test period. The moisture content of the exterior sheathing of the north panel increased to a maximum of 18% wt in the vicinity of the hole, but quickly dried when the ambient temperatures increased towards the end of the season. The south panel showed very little moisture accumlation due to the effects of solar radiation. 14 refs., 9 figs.

  20. Automated borehole gravity meter system

    International Nuclear Information System (INIS)

    Lautzenhiser, Th.V.; Wirtz, J.D.

    1984-01-01

    An automated borehole gravity meter system for measuring gravity within a wellbore. The gravity meter includes leveling devices for leveling the borehole gravity meter, displacement devices for applying forces to a gravity sensing device within the gravity meter to bring the gravity sensing device to a predetermined or null position. Electronic sensing and control devices are provided for (i) activating the displacement devices, (ii) sensing the forces applied to the gravity sensing device, (iii) electronically converting the values of the forces into a representation of the gravity at the location in the wellbore, and (iv) outputting such representation. The system further includes electronic control devices with the capability of correcting the representation of gravity for tidal effects, as well as, calculating and outputting the formation bulk density and/or porosity

  1. Robust Meter Network for Water Distribution Pipe Burst Detection

    OpenAIRE

    Donghwi Jung; Joong Hoon Kim

    2017-01-01

    A meter network is a set of meters installed throughout a water distribution system to measure system variables, such as the pipe flow rate and pressure. In the current hyper-connected world, meter networks are being exposed to meter failure conditions, such as malfunction of the meter’s physical system and communication system failure. Therefore, a meter network’s robustness should be secured for reliable provision of informative meter data. This paper introduces a multi-objective optimal me...

  2. Microwave bale moisture sensing: Field trial

    Science.gov (United States)

    A microwave moisture measurement technique was developed for moisture sensing of cotton bales after the bale press. The technique measures the propagation delay of a microwave signal that is transmitted through the cotton bale. This research conducted a field trial to test the sensor in a commercial...

  3. Combining satellite radar altimetry, SAR surface soil moisture and GRACE total storage changes for model calibration and validation in a large ungauged catchment

    DEFF Research Database (Denmark)

    Milzow, Christian; Krogh, Pernille Engelbredt; Bauer-Gottwein, Peter

    2010-01-01

    The availability of data is a major challenge for hydrological modelling in large parts of the world. Remote sensing data can be exploited to improve models of ungauged or poorly gauged catchments. In this study we combine three datasets for calibration and validation of a rainfall-runoff model...... of the ungauged Okavango catchment in Southern Africa: (i) Surface soil moisture (SSM) estimates derived from SAR measurements onboard the Envisat satellite; (ii) Radar altimetry measurements by Envisat providing river stages in the tributaries of the Okavango catchment, down to a minimum width of about one...... hundred meters; and (iii) Temporal changes of the Earth’s gravity field recorded by the Gravity Recovery and Climate Experiment (GRACE) caused by total water storage changes in the catchment. The SSM data are compared to simulated moisture conditions in the top soil layer. They cannot be used for model...

  4. A new probe for in situ TDR moisture measurement

    Energy Technology Data Exchange (ETDEWEB)

    Yokuda, E. (EG and G Idaho, Inc., Idaho Falls, ID (United States)); Smith, R. (Sonsub Services, Inc., Houston, TX (United States))

    1993-01-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented.

  5. A new probe for in situ TDR moisture measurement

    International Nuclear Information System (INIS)

    Yokuda, E.; Smith, R.

    1993-01-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented

  6. A new probe for in situ TDR moisture measurement

    Energy Technology Data Exchange (ETDEWEB)

    Yokuda, E. [EG and G Idaho, Inc., Idaho Falls, ID (United States); Smith, R. [Sonsub Services, Inc., Houston, TX (United States)

    1993-05-01

    This paper explains the development of a new Time Domain Reflectometry (TDR) probe which can be inserted through waste and soil to a depth of 14 feet with minimal labor and minimal soil disturbance. TDR has been used for 10 years as a method for measuring soil moisture contents. Conventional TDR probes are 30 centimeters long and therefore are difficult to insert at depths below a few feet. Recently, a probe has been developed which can be inserted to depths of 14 feet with the use of a vibratory drill. Quality objectives for the instrument, preliminary data, and suggestions for future developments are presented.

  7. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  8. Increased profitability in cellulose production through more accurate measurement of the moisture content

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    A general report on the project 'Dry Wood' is presented. In this project Noratom-Norcontrol A/S cooperate with the wood-pulp and paper factory Petersen and Soen in the application of Noratom's radiometric moisture gauge and their continuous weighing machine (densimeter) in the continuous measurement of the moisture content of wood chips in cellulose production. Conventional methods give an accuracy of π+ 2% and the objective of this method is an accuracy of π+ 1%. This would have a considerable economic significance. A test unit has been operating in the production line for a year and has attained the objective for short periods. Improved long term stability is the present problem. The system has process outputs which will facilitate future on-line computer process control. (JIW)

  9. Topology-Based Estimation of Missing Smart Meter Readings

    Directory of Open Access Journals (Sweden)

    Daisuke Kodaira

    2018-01-01

    Full Text Available Smart meters often fail to measure or transmit the data they record when measuring energy consumption, known as meter readings, owing to faulty measuring equipment or unreliable communication modules. Existing studies do not address successive and non-periodical missing meter readings. This paper proposes a method whereby missing readings observed at a node are estimated by using circuit theory principles that leverage the voltage and current data from adjacent nodes. A case study is used to demonstrate the ability of the proposed method to successfully estimate the missing readings over an entire day during which outages and unpredictable perturbations occurred.

  10. Soil moisture variability across different scales in an Indian watershed for satellite soil moisture product validation

    KAUST Repository

    Singh, Gurjeet

    2016-05-05

    Strategic ground-based sampling of soil moisture across multiple scales is necessary to validate remotely sensed quantities such as NASA’s Soil Moisture Active Passive (SMAP) product. In the present study, in-situ soil moisture data were collected at two nested scale extents (0.5 km and 3 km) to understand the trend of soil moisture variability across these scales. This ground-based soil moisture sampling was conducted in the 500 km2 Rana watershed situated in eastern India. The study area is characterized as sub-humid, sub-tropical climate with average annual rainfall of about 1456 mm. Three 3x3 km square grids were sampled intensively once a day at 49 locations each, at a spacing of 0.5 km. These intensive sampling locations were selected on the basis of different topography, soil properties and vegetation characteristics. In addition, measurements were also made at 9 locations around each intensive sampling grid at 3 km spacing to cover a 9x9 km square grid. Intensive fine scale soil moisture sampling as well as coarser scale samplings were made using both impedance probes and gravimetric analyses in the study watershed. The ground-based soil moisture samplings were conducted during the day, concurrent with the SMAP descending overpass. Analysis of soil moisture spatial variability in terms of areal mean soil moisture and the statistics of higher-order moments, i.e., the standard deviation, and the coefficient of variation are presented. Results showed that the standard deviation and coefficient of variation of measured soil moisture decreased with extent scale by increasing mean soil moisture. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

  11. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  12. Effectiveness of modified 1-hour air-oven moisture methods for determining popcorn moisture

    Science.gov (United States)

    Two of the most commonly used approved grain moisture air-oven reference methods are the air oven method ASAE S352.2, which requires long heating time (72-h) for unground samples, and the AACC 44-15.02 air-oven method, which dries a ground sample for 1 hr, but there is specific moisture measurement ...

  13. The study of high precision neutron moisture gauge

    International Nuclear Information System (INIS)

    Liu Shengkang; Bao Guanxiong; Sang Hai; Zhu Yuzhen

    1993-01-01

    The principle, structure and calibration experiment of the high precision neutron moisture gauge (insertion type) are described. The gauge has been appraised. The precision of the measuring moisture of coke is lower than 0.5%, and the range of the measuring moisture is 2%-12%. The economic benefit of the gauge application is good

  14. Transverse micro-erosion meter measurements; determining minimum sample size

    Science.gov (United States)

    Trenhaile, Alan S.; Lakhan, V. Chris

    2011-11-01

    Two transverse micro-erosion meter (TMEM) stations were installed in each of four rock slabs, a slate/shale, basalt, phyllite/schist, and sandstone. One station was sprayed each day with fresh water and the other with a synthetic sea water solution (salt water). To record changes in surface elevation (usually downwearing but with some swelling), 100 measurements (the pilot survey), the maximum for the TMEM used in this study, were made at each station in February 2010, and then at two-monthly intervals until February 2011. The data were normalized using Box-Cox transformations and analyzed to determine the minimum number of measurements needed to obtain station means that fall within a range of confidence limits of the population means, and the means of the pilot survey. The effect on the confidence limits of reducing an already small number of measurements (say 15 or less) is much greater than that of reducing a much larger number of measurements (say more than 50) by the same amount. There was a tendency for the number of measurements, for the same confidence limits, to increase with the rate of downwearing, although it was also dependent on whether the surface was treated with fresh or salt water. About 10 measurements often provided fairly reasonable estimates of rates of surface change but with fairly high percentage confidence intervals in slowly eroding rocks; however, many more measurements were generally needed to derive means within 10% of the population means. The results were tabulated and graphed to provide an indication of the approximate number of measurements required for given confidence limits, and the confidence limits that might be attained for a given number of measurements.

  15. Influence of Moisture Absorption and Content of Graphite Filler on Electrical Property of Sensors and Transducers Enclosures and Phenomena of Electrostriction in Glass- Epoxy Composites

    Directory of Open Access Journals (Sweden)

    B. Shivamurthy

    2008-10-01

    Full Text Available In this investigation E-glass epoxy composite filled with different amount of graphite particles were prepared by compression. Plain waived E-glass cloth with density 200g / meter square was used as reinforcement. Epoxy resin LY556 mixed with Hardener HT907 and accelerator DY063 in the ratio 100:80:2 were used as matrix. The graphite of 50 particle size was used as fillers. Four types of composites were prepared with different amount of graphite fillers viz 0 %, 3 %, 6 % and 9 % with unchanged reinforcement. After subjecting the samples to water absorption up to 96 hours in steps of 24 hrs, dielectric dissipation factor (tan δ, dielectric constant and a. c. conductivity have been measured by using a LCR meter at two different frequencies (100 Hz and 1 kHz. Results show that tan δ direct constant, a.c. conductivity increases with increase in % of graphite in the composites at both high and low frequency for dry samples. Samples with 24 hrs moisture absorption showed approximately same result. After 48 hrs, tan δ values showed variations. However, the fluctuations were less at 6 % of graphite in all samples after 48 and 72 hrs of moisture absorption. Dielectric constant increases with increase in graphite % in composites at higher frequency and there was not much variation at low frequency. In all samples after 24 and 48 hrs of moisture absorption, dielectric constant decreases with increase in graphite loading. It is observed that dielectric constant increases in all samples after 72 hrs of moisture absorption as compared to dry samples. A c. conductivity increases with increase in % of graphite content in dry sample. Up to 6% a. c. conductivity increases after 24 and 48 hrs of immersion, after 72 hrs the trend is reversed. Since Fermi level is initially shifted towards the conduction band and then after 72 hrs of moisture absorption shifted towards the valence band. a. c. conductivity increases with increase in moisture content. The

  16. Characterization of radiofrequency field emissions from smart meters.

    Science.gov (United States)

    Tell, Richard A; Kavet, Robert; Mezei, Gabor

    2013-01-01

    This study presents measurement data that describe radiofrequency emission levels and patterns from smart meters (rated nominally at 1 W) currently deployed in Pacific Gas and Electric Company's service territory in northern California. The smart meters in our investigation could not be set to operate continuously and required a Field Service Unit to induce short periods of emitted fields. To obtain peak field data under both laboratory and ambient conditions, a spectrum analyzer scanned across the 83 transmitting channels between 902 and 928 MHz used by the smart meter on a random frequency-hopping basis. To obtain data describing temporal emission patterns, the analyzer operated in scope mode. Duty cycle was estimated using transmit data acquired by the system operator from over 88,000 m. Instantaneous peak fields at 0.3 m in front of the meters were no more than 15% of the US Federal Communications Commission (FCC) exposure limit for the general public, and 99.9% of the meters operated with a duty cycle of 1.12% or less during the sampling period. In a sample of measurements in six single-detached residences equipped with individual smart meters, no interior measurement of peak field exceeded 1% of the FCC's general public exposure limit.

  17. Effects of soil moisture on the diurnal pattern of pesticide emission: Comparison of simulations with field measurements

    Science.gov (United States)

    Reichman, Rivka; Yates, Scott R.; Skaggs, Todd H.; Rolston, Dennis E.

    2013-02-01

    Pesticide volatilization from agricultural soils is one of the main pathways in which pesticides are dispersed in the environment and affects ecosystems including human welfare. Thus, it is necessary to have accurate knowledge of the various physical and chemical mechanisms that affect volatilization rates from field soils. A verification of the influence of soil moisture modeling on the simulated volatilization rate, soil temperature and soil-water content is presented. Model simulations are compared with data collected in a field study that measured the effect of soil moisture on diazinon volatilization. These data included diurnal changes in volatilization rate, soil-water content, and soil temperature measured at two depths. The simulations were performed using a comprehensive non-isothermal model, two water retention functions, and two soil surface resistance functions, resulting in four tested models. Results show that the degree of similarity between volatilization curves simulated using the four models depended on the initial water content. Under fairly wet conditions, the simulated curves mainly differ in the magnitude of their deviation from the measured values. However, under intermediate and low moisture conditions, the simulated curves also differed in their pattern (shape). The model prediction accuracy depended on soil moisture. Under normal practices, where initial soil moisture is about field capacity or higher, a combination of Brooks and Corey water retention and the van de Grind and Owe soil surface resistance functions led to the most accurate predictions. However, under extremely dry conditions, when soil-water content in the top 1 cm is below the volumetric threshold value, the use of a full-range water retention function increased prediction accuracy. The different models did not affect the soil temperature predictions, and had a minor effect on the predicted soil-water content of Yolo silty clay soil.

  18. Digital Receiver Phase Meter

    Science.gov (United States)

    Marcin, Martin; Abramovici, Alexander

    2008-01-01

    The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.

  19. In vivo skin moisturizing measurement by high-resolution 3 Tesla magnetic resonance imaging.

    Science.gov (United States)

    Mesrar, J; Ognard, J; Garetier, M; Chechin, D; Misery, L; Ben Salem, D

    2017-08-01

    Magnetic resonance imaging (MRI) is rarely used for the exploration of skin, even if studies have validated both feasibility of skin MRI and its interest for anatomical, physiological, and biochemical study of the skin. The purpose of this study is to explore moisturizing of the different skin layers using 3-T scan. An MRI of the heel's skin was performed using a 23 mm coil diameter on a 3T scan with a FFE (Fast Field Echo) 3D T1-weighted sequence and a TSE (Turbo Spin Echo) calculation T2-weighted sequence (pixels size of respectively 60 and 70 μm). This study was conducted on 35 healthy volunteers, who were scanned before applying moisturizer topic and 1 h after applying it. Region of interest in the stratum corneum, the epidermis and the dermis were generated on the T2 mapping. The thickness of each layer was measured. The T1 sequence allowed accurate cross-examination repositioning to ensure the comparability of the measurements. Among the 35 cases, two were excluded from the analysis because of movement artifacts. Measurements before and after moisturizer topic application displayed a T2 increase of 48.94% (P < 0.0001) in the stratum corneum and of 5.45% (P < 0.0001) in the epidermis yet without significant difference in the dermis. There was no significant link between the thickness of the stratum corneum and the T2 increase. However, there was a strong correlation between the thickness of the stratum corneum and the thickness of the epidermis (P < 0.001; rhô=0.72). High-resolution MRI allows fine exploration of anatomical and physiological properties of the skin and can further be used to extend the studies of skin hydration. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Correlation between laser-induced breakdown spectroscopy signal and moisture content

    International Nuclear Information System (INIS)

    Liu, Yuan; Gigant, Lionel; Baudelet, Matthieu; Richardson, Martin

    2012-01-01

    The possibility of using Laser-Induced Breakdown Spectroscopy (LIBS) for measuring the moisture content of fresh food samples is studied. The normalized line emission of oxygen is highly correlated with the moisture content of the sample, cheese in our case, and can be used as a moisture marker in situations where oxygen interference from the matrix is not a critical issue. The linear correlation between the oxygen signal and the moisture content in the sample shows great potential for using LIBS as an alternative spectroscopic method for moisture monitoring. - Highlights: ► Quantitative moisture measurement by LIBS. ► Use of matrix effects and normalization for physical information on the sample. ► Use of signal from oxygen and CN radical in air background for moisture measurement.

  1. 40 CFR 1065.230 - Raw exhaust flow meter.

    Science.gov (United States)

    2010-07-01

    ... the following cases, you may use a raw exhaust flow meter signal that does not give the actual value... dew and pressure, p total at the flow meter inlet. Use these values in emission calculations according... CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.230 Raw exhaust...

  2. Fission Meter Information Barrier Attribute Measurement System: Task 1 Report: Document existing Fission Meter neutron IB system

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, P. L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-28

    An SNM attribute Information Barrier (IB) system was developed for a 2011 US/UK Exercise. The system was modified and extensively tested in a 2013-2014 US-UK Measurement Campaign. This work demonstrated rapid deployment of an IB system for potential treaty use. The system utilizes an Ortec Fission Meter neutron multiplicity counter and custom computer code. The system demonstrates a proof-of-principle automated Pu-240 mass determination with an information barrier. After a software start command is issued, the system automatically acquires and downloads data, performs an analysis, and displays the results. This system conveys the results of a Pu mass threshold measurements in a way the does not reveal sensitive information. In full IB mode, only red/green ‘lights’ are displayed in the software. In test mode, more detailed information is displayed. The code can also read in, analyze, and display results from previously acquired or simulated data. Because the equipment is commercial-off-the-shelf (COTS), the system demonstrates a low-cost short-lead-time technology for treaty SNM attribute measurements. A deployed system will likely require integration of additional authentication and tamper-indicating technologies. This will be discussed for the project in this and future progress reports.

  3. Comparison of Soil Moisture in Switzerland Using In-Situ Measurements and Model Output

    Science.gov (United States)

    Mittelbach, H.; Orth, R.; Seneviratne, S. I.

    2011-01-01

    Soil moisture is an essential contributor to land surface- atmosphere interactions. In this study we evaluate the two Land surface models CLM3.5 and SIB3 regarding their performance in simulating soil moisture and its anomalies for the one year period 01.09.2009 to 31.08.2010. Four grassland sites from the SwissSMEX/- Veg project were used as reference soil moisture data. In general, both models represent the soil moisture anomalies and their distribution better than the absolute soil moisture. Furthermore, both models show a seasonal dependence of the correlation and root mean square error. In contrast to the SIB3 model, the CLM3.5 model shows stronger seasonal variation of the root mean square error and a larger interquantile range for soil moisture anomalies.

  4. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement

    Directory of Open Access Journals (Sweden)

    Eunjong Kim

    2016-05-01

    Full Text Available Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS’s optimum moisture content was near saturated state, its free air space kept a favorable level (above 30% for aerobic composting due to the sawdust’s coarse particle size and bulking effect.

  5. Evaluation of Optimum Moisture Content for Composting of Beef Manure and Bedding Material Mixtures Using Oxygen Uptake Measurement.

    Science.gov (United States)

    Kim, Eunjong; Lee, Dong-Hyun; Won, Seunggun; Ahn, Heekwon

    2016-05-01

    Moisture content influences physiological characteristics of microbes and physical structure of solid matrices during composting of animal manure. If moisture content is maintained at a proper level, aerobic microorganisms show more active oxygen consumption during composting due to increased microbial activity. In this study, optimum moisture levels for composting of two bedding materials (sawdust, rice hull) and two different mixtures of bedding and beef manure (BS, Beef cattle manure+sawdust; BR, Beef cattle manure+rice hull) were determined based on oxygen uptake rate measured by a pressure sensor method. A broad range of oxygen uptake rates (0.3 to 33.3 mg O2/g VS d) were monitored as a function of moisture level and composting feedstock type. The maximum oxygen consumption of each material was observed near the saturated condition, which ranged from 75% to 98% of water holding capacity. The optimum moisture content of BS and BR were 70% and 57% on a wet basis, respectively. Although BS's optimum moisture content was near saturated state, its free air space kept a favorable level (above 30%) for aerobic composting due to the sawdust's coarse particle size and bulking effect.

  6. Methodical comparison of neutron depth probes and long-term soil moisture measurements on loess, sandy loess, and boulder clay

    International Nuclear Information System (INIS)

    Neue, H.U.

    1980-01-01

    Three measuring instruments were tested: 0.05 mCi Cf-252, 100 mCi Am-241/Be, 500 mCi Am-241/Be. The advantages - measurement in undisturbed soil profiles, large depths of measurement, reproducibility of measurements in the same place over several years - and the disadvantages - radiation protection, resolution, variations of measured volume in dependence of moisture, background influences etc. - have been critically checked by experiment. In addition, annual soil moisture curves have been measured over two years by parallel use of the free probes on a loess, sandy loess, and boulder clay site. The results were compared and discussed with a view to the soil water dynamics of these sites. (orig./HP) [de

  7. Smart metering - energy data management at every meter point; Smart Metering - Energiedatenmanagement an jedem Zaehlpunkt

    Energy Technology Data Exchange (ETDEWEB)

    Keller-Giessbach, D.; Kiel, E. [LogicaCMG, Muenchen (Germany)

    2007-09-15

    The demise of monopolistic structures in the German energy market has also led to a change of perspective on metering. New requirements have to be met. Even in mass processing jobs such as meter reading it is no longer sufficient to simply read consumption data off a technically reliable meter or have customers do this themselves in preparation of billing. Currently used meters were not designed with a mind to demand management, environmental protection through energy conservation, changes in consumer behaviour or new service offers. This has been recognised in many European countries since the beginning of the present decade. The traditional task of metering is developing into a more comprehensive energy data management that takes account of the needs of customers, energy suppliers and regulatory requirements.

  8. Hybrid TLC-pair meter for the Sphinx Project

    Science.gov (United States)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

  9. Hybrid TLC-pair meter for the Sphinx Project

    International Nuclear Information System (INIS)

    Wada, T.; Yamamoto, I.; Takahashi, N.; Misaki, A.

    1985-01-01

    The chief aims in the Sphinx Project are research on super lepton physics and new detector experiments. In the second phase of the Sphinx Project, a hybrid TLC-pair meter was designed for measuring for high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV), and measuring muon groups (E mu 1 TeV). The principle of the pair meter has been already proposed. In this TLC pair meter, electromagnetic showers induced by cosmic ray muons are detected using thermoluminescene sheets with position counters

  10. Low Cost Digital Vibration Meter.

    Science.gov (United States)

    Payne, W Vance; Geist, Jon

    2007-01-01

    This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibration of the device in the plane perpendicular to the cantilever beam causes it to bend, which produces a measurable change in the resistance of a piezoresistor. These changes in resistance along with a unique signal-processing scheme are used to determine an approximation to the RMS acceleration sensed by the device.

  11. FLOW METERS WITH VERY GOOD PERFORMANCES

    Directory of Open Access Journals (Sweden)

    Mircea Dimitrie CAZACU

    2011-11-01

    Full Text Available We present the theoretical calculus of a patented flow meter, concerning such the thermodynamic and aerodynamic calculus, as well as the offered precision to measure the flow of the air in any meteorological conditions. In the same time we remark that the proposed flow meter, by its positioning, has not loss of head.

  12. Logging effects on soil moisture losses

    Science.gov (United States)

    Robert R. Ziemer

    1978-01-01

    Abstract - The depletion of soil moisture within the surface 15 feet by an isolated mature sugar pine and an adjacent uncut forest in the California Sierra Nevada was measured by the neutron method every 2 weeks for 5 consecutive summers. Soil moisture recharge was measured periodically during the intervening winters. Groundwater fluctuations within the surface 50...

  13. MoisturEC: an R application for geostatistical estimation of moisture content from electrical conductivity data

    Science.gov (United States)

    Terry, N.; Day-Lewis, F. D.; Werkema, D. D.; Lane, J. W., Jr.

    2017-12-01

    Soil moisture is a critical parameter for agriculture, water supply, and management of landfills. Whereas direct data (as from TDR or soil moisture probes) provide localized point scale information, it is often more desirable to produce 2D and/or 3D estimates of soil moisture from noninvasive measurements. To this end, geophysical methods for indirectly assessing soil moisture have great potential, yet are limited in terms of quantitative interpretation due to uncertainty in petrophysical transformations and inherent limitations in resolution. Simple tools to produce soil moisture estimates from geophysical data are lacking. We present a new standalone program, MoisturEC, for estimating moisture content distributions from electrical conductivity data. The program uses an indicator kriging method within a geostatistical framework to incorporate hard data (as from moisture probes) and soft data (as from electrical resistivity imaging or electromagnetic induction) to produce estimates of moisture content and uncertainty. The program features data visualization and output options as well as a module for calibrating electrical conductivity with moisture content to improve estimates. The user-friendly program is written in R - a widely used, cross-platform, open source programming language that lends itself to further development and customization. We demonstrate use of the program with a numerical experiment as well as a controlled field irrigation experiment. Results produced from the combined geostatistical framework of MoisturEC show improved estimates of moisture content compared to those generated from individual datasets. This application provides a convenient and efficient means for integrating various data types and has broad utility to soil moisture monitoring in landfills, agriculture, and other problems.

  14. Reactor Power Meter type SG-8

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The report describes the principle and electronic circuits of the Reactor Power Meter type SG-8. The gamma radiation caused by the activity of the reactor first cooling circuit affectes the ionization chamber being the detector of the instrument. The output detector signal direct current is converted into the frequency of electric pulses by means of the current-to-frequency converter. The output converter frequency is measured by the digital frequency meter: the number of measured digits in time unit is proportional to the reactor power.

  15. Correlation between laser-induced breakdown spectroscopy signal and moisture content

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yuan [Townes Laser Institute, CREOL - The College of Optics and Photonics, University of Central Florida, 4000 Central Florida Boulevard, Orlando, FL 32816 (United States); Gigant, Lionel [Townes Laser Institute, CREOL - The College of Optics and Photonics, University of Central Florida, 4000 Central Florida Boulevard, Orlando, FL 32816 (United States); Universite Bordeaux 1, 351 cours de la Liberation 33405 Talence Cedex (France); Baudelet, Matthieu, E-mail: baudelet@creol.ucf.edu [Townes Laser Institute, CREOL - The College of Optics and Photonics, University of Central Florida, 4000 Central Florida Boulevard, Orlando, FL 32816 (United States); Richardson, Martin [Townes Laser Institute, CREOL - The College of Optics and Photonics, University of Central Florida, 4000 Central Florida Boulevard, Orlando, FL 32816 (United States)

    2012-07-15

    The possibility of using Laser-Induced Breakdown Spectroscopy (LIBS) for measuring the moisture content of fresh food samples is studied. The normalized line emission of oxygen is highly correlated with the moisture content of the sample, cheese in our case, and can be used as a moisture marker in situations where oxygen interference from the matrix is not a critical issue. The linear correlation between the oxygen signal and the moisture content in the sample shows great potential for using LIBS as an alternative spectroscopic method for moisture monitoring. - Highlights: Black-Right-Pointing-Pointer Quantitative moisture measurement by LIBS. Black-Right-Pointing-Pointer Use of matrix effects and normalization for physical information on the sample. Black-Right-Pointing-Pointer Use of signal from oxygen and CN radical in air background for moisture measurement.

  16. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  17. Use of moisture probes in building materials industry

    International Nuclear Information System (INIS)

    Hanke, L.

    A neutron probe to be built in the production line was developed for monitoring moisture content of bulk materials and suspensions of all types in the building material industry. The probe is dust- and external moisture-protected. The probe measuring capacity is about 100 l, the mean measurement error is +- 0.008 g water per 1 cm 3 , which for fine sand represents an error of +- 0.3%. The probe is connected via a cable to a measuring instrument showing an electrical value proportional to the measured material moisture content. (Z.M.)

  18. Coal Moisture Estimation in Power Plant Mills

    DEFF Research Database (Denmark)

    Andersen, Palle; Bendtsen, Jan Dimon; Pedersen, Tom S.

    2009-01-01

    Knowledge of moisture content in raw coal feed to a power plant coal mill is of importance for efficient operation of the mill. The moisture is commonly measured approximately once a day using offline chemical analysis methods; however, it would be advantageous for the dynamic operation...... of the plant if an on-line estimate were available. In this paper we such propose an on-line estimator (an extended Kalman filter) that uses only existing measurements. The scheme is tested on actual coal mill data collected during a one-month operating period, and it is found that the daily measured moisture...

  19. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    Science.gov (United States)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  20. Method to estimate the internal stresses due to moisture in wood using transmission properties of microwaves

    International Nuclear Information System (INIS)

    Takemura, T.; Taniguchi, T.

    2004-01-01

    The purpose of this paper is to offer a new method for detecting stress in wood due to moisture along the lines of a theory reported previously. According to the theory, the stress in wood could be estimated from the moisture content of the wood and the power voltage of a microwave moisture meter (i.e., attenuation of the projected microwave). This seems to suggest a possibility of utilizing microwaves in the field of stress detection. To develop such an idea, the stress formulas were initially modified to the form of an uni-variable function of power voltage, and the application method of the formulas to detection was tried. Finally, these results were applied to the data of sugi (Cryptomeria japonica) lumber in the previous experiment. The estimated strains showed fairly good agreement with those observed. It could be concluded from this study that the proposed method might be available for detecting stress in wood due to moisture

  1. Moisture parameters and fungal communities associated with gypsum drywall in buildings.

    Science.gov (United States)

    Dedesko, Sandra; Siegel, Jeffrey A

    2015-12-08

    Uncontrolled excess moisture in buildings is a common problem that can lead to changes in fungal communities. In buildings, moisture parameters can be classified by location and include assessments of moisture in the air, at a surface, or within a material. These parameters are not equivalent in dynamic indoor environments, which makes moisture-induced fungal growth in buildings a complex occurrence. In order to determine the circumstances that lead to such growth, it is essential to have a thorough understanding of in situ moisture measurement, the influence of building factors on moisture parameters, and the levels of these moisture parameters that lead to indoor fungal growth. Currently, there are disagreements in the literature on this topic. A literature review was conducted specifically on moisture-induced fungal growth on gypsum drywall. This review revealed that there is no consistent measurement approach used to characterize moisture in laboratory and field studies, with relative humidity measurements being most common. Additionally, many studies identify a critical moisture value, below which fungal growth will not occur. The values defined by relative humidity encompassed the largest range, while those defined by moisture content exhibited the highest variation. Critical values defined by equilibrium relative humidity were most consistent, and this is likely due to equilibrium relative humidity being the most relevant moisture parameter to microbial growth, since it is a reasonable measure of moisture available at surfaces, where fungi often proliferate. Several sources concur that surface moisture, particularly liquid water, is the prominent factor influencing microbial changes and that moisture in the air and within a material are of lesser importance. However, even if surface moisture is assessed, a single critical moisture level to prevent fungal growth cannot be defined, due to a number of factors, including variations in fungal genera and

  2. Microwave bale moisture sensing: Field trial continued

    Science.gov (United States)

    A microwave moisture measurement technique was developed at the USDA, ARS Cotton Production and Processing Research Unit for moisture sensing of cotton bales after the bale press. The technique measures the propagation delay of a microwave signal that is transmitted through the cotton bale. This res...

  3. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  4. Development of the impedance void meter

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Moon Ki; Song, Chul Hwa; Won, Soon Yeon; Kim, Bok Deuk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    An impedance void meter is developed to measure the area-averaged void fraction. Its basic principle is based on the difference in the electrical conductivity between phases. Several methods of measuring void fraction are briefly reviewed and the reason why this type of void meter is chosen to develop is discussed. Basic principle of the measurement is thoroughly described and several design parameters to affect the overall function are discussed in detail. As example of applications is given for vertical air-water flow. It is shown that the current design has good dynamic response as well as very fine spatial resolution. (Author) 47 refs., 37 figs.

  5. Smart Metering. Technological, economic and legal aspects. 2. ed.; Smart Metering. Technologische, wirtschaftliche und juristische Aspekte des Smart Metering

    Energy Technology Data Exchange (ETDEWEB)

    Koehler-Schute, Christiana (ed.)

    2010-07-01

    Smart metering comprises more than just meter technology, and the use of information and communication technologies is indispensable. Processes, roles and business models must be reconsidered as further challenges arise in the context of smart metering. For one, there is the operator of the metering points. Secondly, there is the end user who is in the role of an active market partner. Further, there is smart metering as a basic technology, e.g. for smart grids and smart homes. In spite of the need for action, many utilities are reluctant to introduce smart metering. Reasons for this are the cost, a lack of defined standards, and an unclear legal situation. On the other hand, smart metering offers potential for grids and distribution that should be made use of. The authors discuss all aspects of the subject. The point out the chances and limitations of smart metering and present their own experience. [German] Smart Metering geht weit ueber die Zaehlertechnologie hinaus und der Einsatz von Informations- und Kommunikationstechnologien ist unabdingbar. Damit einhergehend muessen Prozesse, Rollen und auch Geschaeftsmodelle neu durchdacht werden. Denn weitere Herausforderungen stehen im direkten Zusammenhang mit Smart Metering. Das ist zum einen die Rolle des Messstellenbetreibers / Messdienstleisters. Das ist zum anderen der Endnutzer, dem die Rolle des aktiven Marktpartners zugedacht wird. Das ist des Weiteren das Smart Metering als Basistechnologie beispielsweise fuer Smart Grid und Smart Home. Trotz des Handlungsdrucks stehen viele Unternehmen der Energiewirtschaft dem Smart Metering zurueckhaltend gegenueber. Drei gewichtige Gruende werden ins Feld gefuehrt: die Kostenfrage, nicht definierte Standards und die in vielen Bereichen ungeklaerte Gesetzeslage. Demgegenueber bietet das Smart Metering Potenziale fuer Netz und Vertrieb, die es zu nutzen gilt. Die Autoren setzen sich in ihren Beitraegen mit diesen Themen auseinander, zeigen Chancen, aber auch Grenzen des

  6. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  7. Establishment of a procedure to calculate the measurement uncertainties in radiation survey meters calibration

    International Nuclear Information System (INIS)

    Manzoli, J.E.; Potiens, M.P.A.

    2000-01-01

    The Calibration Laboratory of Sao Paulo calibrates more than one thousand gamma ray survey meters a year; beside other kinds of radiotherapy, radiodiagnostic and radiation protection instruments. It has a standard (600 cm 3 ) cylinder ionization chamber (Nuclear Enterprises Ltd. model 2511/3) traceable to the Brazilian Secondary Standard Dosimetry Laboratory (SSDL) whose instruments are traceable to the BIPM. Annually the beam dosimetry is performed using this chamber and the results are used as the true values for calibration purposes. The uncertainties present in every direct or indirect measurement during the calibration procedure must be evaluated for purposes of laboratory quality control. All calculation steps in the propagation of errors are presented in this work staging from the ionization chamber charge measured with the standard instrument. Such a propagation was made in space and time, considering even the environmental quantities uncertainties. The propagation was necessary in space, because the ionization chamber measurements were performed at only one space position. The time propagation was essential due to the fact that the activity is a peculiar physical quantity which changes with time according to precise relations for a specific radionuclide. The clear indication of every measurement uncertainty is always important to quantify the quality of this measurement. Nowadays the achievement of calibration laboratory quality systems requires the expression of all uncertainties and the procedure used to evaluate it. An example of this procedure in the case of the calibration of a typical portable radiation survey meter is presented. The direct exposure rate instrument measurement was compared with the true value given by the standard instrument properly propagated and all quantities used have their uncertainties shown. (author)

  8. Evaluation of free water and water activity measurements as functional alternatives to total moisture content in broiler excreta and litter samples

    NARCIS (Netherlands)

    Hoeven-Hangoor, van der E.; Rademaker, C.; Paton, N.D.; Verstegen, M.W.A.; Hendriks, W.H.

    2014-01-01

    Litter moisture contents vary greatly between and within practical poultry barns. The current experiment was designed to measure the effects of 8 different dietary characteristics on litter and excreta moisture content. Additionally, free water content and water activity of the excreta and litter

  9. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  10. Metering instrument of quality factor Q of gravitational wave antenna

    International Nuclear Information System (INIS)

    Jia-yan, C.; Tong-ren, G.

    1982-01-01

    The quality factor, Q, of gravitational wave antenna depends on the material property as well as external conditions, such as temperature, residual pressure in vacuum tank, support type, additional loss from transducer on antenna, etc. In order to find out the relationship between the antenna Q and external conditions automatical operating in succession is required. The authors have designed and made a metering instrument for quality factor Q. The metering instrument of Q can measure Q of the metal cylinder and other bar of higher Q. It can give data of the measurement at regular intervals as desired. It can measure accurately the longitudinal fundamental mode frequency of the cylinder with a digital frequency meter record oscillating signal from metering instrument. Because the metering instrument excites free-vibration of the cylinder with free-running type and keep up the stationary amplitude for a long time. (Auth.)

  11. A simple algorithm to retrieve soil moisture and vegetation biomass using passive microwave measurements over crop fields

    International Nuclear Information System (INIS)

    Wigneron, J.P.; Chanzy, A.; Calvet, J.C.; Bruguier, N.

    1995-01-01

    A simple algorithm to retrieve sail moisture and vegetation water content from passive microwave measurements is analyzed in this study. The approach is based on a zeroth-order solution of the radiative transfer equations in a vegetation layer. In this study, the single scattering albedo accounts for scattering effects and two parameters account for the dependence of the optical thickness on polarization, incidence angle, and frequency. The algorithm requires only ancillary information about crop type and surface temperature. Retrievals of the surface parameters from two radiometric data sets acquired over a soybean and a wheat crop have been attempted. The model parameters have been fitted in order to achieve best match between measured and retrieved surface data. The results of the inversion are analyzed for different configurations of the radiometric observations: one or several look angles, L-band, C-band or (L-band and C-band). Sensitivity of the retrievals to the best fit values of the model parameters has also been investigated. The best configurations, requiring simultaneous measurements at L- and C-band, produce retrievals of soil moisture and biomass with a 15% estimated precision (about 0.06 m 3 /m 3 for soil moisture and 0.3 kg/m 2 for biomass) and exhibit a limited sensitivity to the best fit parameters. (author)

  12. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  13. Measurement of the unaccompanied pion-proton flux ratio at 2,900 meters using a transition radiation detector

    International Nuclear Information System (INIS)

    Ellsworth, R.W.; Ito, A.S.; MacFall, J.R.; Siohan, F.; Streitmatter, R.E.; Tonwar, S.C.; Yodh, G.B.

    1975-01-01

    A transition radiation dedector and an ionization calorimeter have been used to measure the unaccompanied pion to proton flux ratio for energies greater than 400 and 600 GeV at an altitude of 2,900 meters. (orig./BJ) [de

  14. A new kind high-reliability digital reactivity meter

    International Nuclear Information System (INIS)

    Shen Feng; Jiang Zongbing

    2001-01-01

    The paper introduces a new kind of high-reliability Digital Reactivity Meter developed by the DRM developing group in designing department of Nuclear Power Institute of China. The meter has two independent measure channels, which can be set as either master-slave structure or working independently. This structure will ensure that the meter can continually fulfill its online measure task under the condition of single failure with it. It provides a solution for the conflict between nuclear station's extreme demand in DRM's reliability and instability of computer's business software platform. The instrument reaches both advance and reliability by covering a lot of kinds of complex functions in data process and display

  15. Canadian consumer issues in accurate and fair electricity metering

    International Nuclear Information System (INIS)

    2000-07-01

    The Public Interest Advocacy Centre (PIAC), located in Ottawa, participates in regulatory proceedings concerning electricity and natural gas to support public and consumer interest. PIAC provides legal representation, research and policy support and public advocacy. A study aimed toward the determination of the issues at stake for residential electricity consumers in the provision of fair and accurate electricity metering, was commissioned by Measurement Canada in consultation with Industry Canada's Consumer Affairs. The metering of electricity must be carried out in a fair and efficient manner for all residential consumers. The Electricity, Gas and Inspection Act was developed to ensure compliance with standards for measuring instrumentation. The accurate metering of electricity through the distribution systems for electricity in Canada represents the main focus of this study and report. The role played by Measurement Canada and the increased efficiencies of service delivery by Measurement Canada or the changing of electricity market conditions are of special interest. The role of Measurement Canada was explained, as were the concerns of residential consumers. A comparison was then made between the interests of residential consumers and those of commercial and industrial electricity consumers in electricity metering. Selected American and Commonwealth jurisdictions were reviewed in light of their electricity metering practices. A section on compliance and conflict resolution was included, in addition to a section on the use of voluntary codes for compliance and conflict resolution

  16. A neutron dose equivalent meter at CAEP

    International Nuclear Information System (INIS)

    Tian Shihai; Lu Yan; Wang Heyi; Yuan Yonggang; Chen Xu

    2012-01-01

    The measurement of neutron dose equivalent has been a widespread need in industry and research. In this paper, aimed at improving the accuracy of neutron dose equivalent meter: a neutron dose counter is simulated with MCNP5, and the energy response curve is optimized. The results show that the energy response factor is from 0.2 to 1.8 for neutrons in the energy range of 2.53×10 -8 MeV to 10 MeV Compared with other related meters, it turns that the design of this meter is right. (authors)

  17. Measurements of void fraction by an improved multi-channel conductance void meter

    International Nuclear Information System (INIS)

    Song, Chul-Hwa; Chung, Moon Ki; No, Hee Cheon

    1998-01-01

    An improved multi-channel Conductance Void Meter (CVM) was developed to measure a void fraction. Its measuring principle is basically based upon the differences of electrical conductance of a two-phase mixture due to the variation of void fraction around a sensor. The sensor is designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. It is emphasized that the guard electrodes are electrically shielded in order not to affect the measurements of two-phase mixture conductance, but to make the electric fields evenly distributed in a measuring volume. Void fraction is measured for bubbly and slug flow regimes in a vertical air-water loop, and statistical signal processing techniques are applied to show that CVM has a good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel. (author)

  18. Instrumental Develovement of 50 Meters Free Style Swimming Speed Measurement Based on Microcontroller Arduino Uno

    Science.gov (United States)

    Badruzaman; Rusdiana, A.; Gilang, M. R.; Martini, T.

    2017-03-01

    This study is purposed to make a software and hardware instrument in controlling the velocity of 50 meters free style swimming speed measurement based on microcontroller Arduino Uno. The writer uses 6 participants of advanced 2015 college students of sport education. The materials he uses are electronical series of microcontroller Arduino Uno base, laser sensors shone on light dependent resistor, laser receiver functions as a detector of laser cutting block, cables as connector transfering the data. This device consist of 4 installable censors in every 10 meters with the result of swimming speed showed on the monitors using visual basic 6.0 software. This instrument automatically works when the buzzer is pushed and also runs the timer on the application. For the procedure, the writer asks the participants to swim in free style along 50 meters. When the athlete swims, they will cut the laser of every censors so that it gives a signal to stop the running timer on the monitoring application. The output result the writer gets from this used instrument is to know how fast a swimmer swim in maximum speed, to know the time and distance of acceleration and decelaration that happens. The result of validity instrument shows 0,605 (high), while the reliability is 0,833 (very high).

  19. Humidity measurements in passive heat and moisture exchangers applications: a critical issue.

    Science.gov (United States)

    Dubini, G; Fumero, R

    2000-01-01

    A reliable, quantitative assessment of humidification performances of passive heat and moisture exchangers in mechanically-ventilated patients is still to be achieved, although relevant efforts have been made to date. One of the major problems to tackle consists in the difficulty of humidity measurements, both in vivo (during either anaesthesia or intensive care unit treatments) and in vitro set-ups. In this paper a review of the basic operation principles of humidity sensors as well as an analysis of their usage within in vivo and in vitro tests are presented. Particular attention is devoted to the limitations arising from the specific measurement set-up, as they may affect the results notably.

  20. Advanced Metering Implementations - A Perspective from Federal Sector

    Energy Technology Data Exchange (ETDEWEB)

    Eaarni, Shankar

    2014-08-11

    Federal mandate (EPACT 2005) requires that federal buildings install advanced electrical meters-meters capable of providing data at least daily and measuring the consumption of electricity at least hourly. This work presents selected advanced metering implementations to understand some of the existing practices related to data capture and to understand how the data is being translated into information and knowledge that can be used to improve building energy and operational performance to meet federal energy reduction mandates. This study highlights case studies to represent some of the various actions that are being taken based on the data that are being collected to improve overall energy performance of these buildings. Some of these actions include- individualized tenant billing and energy forecasting, benchmarking, identifying energy conservation measures, measurement and verification.

  1. Field and laboratory calibration of neutron probes for soil moisture measurements on a deep loess chernozem soil

    International Nuclear Information System (INIS)

    Schaecke, B.; Schaecke, E.

    1979-01-01

    In the case of a varying profile structure it is necessary to use different calibration curves and adequate correction factors, respectively. The bulk density of the soil had the greatest influence on the calibration. An increase in bulk density by 0.2 g/cm 3 at a clay content of 18% resulted in an apparent increase in the values of moisture measurements by 1.5 to 2.0% of the volume of water. In naturally stratified soil the humus content of the chernozem horizon, being 3% higher than that of the underlying loess horizon, was found to influence the measuring results obtained by the probe. The calibration curves determined for chernozem and loess horizons in the laboratory agreed well with those obtained in the field. The measured values read from the probe and the gravimetrically determined values of the soil moisture were of great significance in all measured depths of the profile. (author)

  2. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  3. Carbon activity meter

    International Nuclear Information System (INIS)

    Roy, P.; Krankota, J.L.

    1975-01-01

    A carbon activity meter utilizing an electrochemical carbon cell with gaseous reference electrodes having particular application for measuring carbon activity in liquid sodium for the LMFBR project is described. The electrolyte container is electroplated with a thin gold film on the inside surface thereof, and a reference electrode consisting of CO/CO 2 gas is used. (U.S.)

  4. Soil moisture determination with Tesla NZK 203 neutron gage

    International Nuclear Information System (INIS)

    Hally, J.

    1977-01-01

    Soil moisture was measured using the NZK 203 neutron probe manufactured by Tesla Premysleni. The individual measuring sites were spaced at a distance of 100 m. The NZK 203 set consists of a NPK 202 moisture gage and a NSK 301 scintillation detector and features the following specifications: moisture density measuring range 20 to 500 kg/m 3 , 241 Am-Be fast neutron source having a neutron flux of 7.5x10 4 n.sec -1 +-10%, operating temperature -10 to +45 degC. The measured counting rate was primarily affected by the statistical fluctuation of ionizing radiation and by instrument instability. In order that these effects should be limited each measurement was repeated 10 times with the optimum measurement time at an interval of 20 to 100 sec. The NZK 203 Tesla set was proven to be suitable for rapid and reproducible determination of moisture profiles. (J.P.)

  5. Self-adaptive Green-Ampt infiltration parameters obtained from measured moisture processes

    Directory of Open Access Journals (Sweden)

    Long Xiang

    2016-07-01

    Full Text Available The Green-Ampt (G-A infiltration model (i.e., the G-A model is often used to characterize the infiltration process in hydrology. The parameters of the G-A model are critical in applications for the prediction of infiltration and associated rainfall-runoff processes. Previous approaches to determining the G-A parameters have depended on pedotransfer functions (PTFs or estimates from experimental results, usually without providing optimum values. In this study, rainfall simulators with soil moisture measurements were used to generate rainfall in various experimental plots. Observed runoff data and soil moisture dynamic data were jointly used to yield the infiltration processes, and an improved self-adaptive method was used to optimize the G-A parameters for various types of soil under different rainfall conditions. The two G-A parameters, i.e., the effective hydraulic conductivity and the effective capillary drive at the wetting front, were determined simultaneously to describe the relationships between rainfall, runoff, and infiltration processes. Through a designed experiment, the method for determining the G-A parameters was proved to be reliable in reflecting the effects of pedologic background in G-A type infiltration cases and deriving the optimum G-A parameters. Unlike PTF methods, this approach estimates the G-A parameters directly from infiltration curves obtained from rainfall simulation experiments so that it can be used to determine site-specific parameters. This study provides a self-adaptive method of optimizing the G-A parameters through designed field experiments. The parameters derived from field-measured rainfall-infiltration processes are more reliable and applicable to hydrological models.

  6. Development of quick-response area-averaged void fraction meter

    International Nuclear Information System (INIS)

    Watanabe, Hironori; Iguchi, Tadashi; Kimura, Mamoru; Anoda, Yoshinari

    2000-11-01

    Authors are performing experiments to investigate BWR thermal-hydraulic instability under coupling of neutronics and thermal-hydraulics. To perform the experiment, it is necessary to measure instantaneously area-averaged void fraction in rod bundle under high temperature/high pressure gas-liquid two-phase flow condition. Since there were no void fraction meters suitable for these requirements, we newly developed a practical void fraction meter. The principle of the meter is based on the electrical conductance changing with void fraction in gas-liquid two-phase flow. In this meter, metal flow channel wall is used as one electrode and a L-shaped line electrode installed at the center of flow channel is used as the other electrode. This electrode arrangement makes possible instantaneous measurement of area-averaged void fraction even under the metal flow channel. We performed experiments with air/water two-phase flow to clarify the void fraction meter performance. Experimental results indicated that void fraction was approximated by α=1-I/I o , where α and I are void fraction and current (I o is current at α=0). This relation holds in the wide range of void fraction of 0∼70%. The difference between α and 1-I/I o was approximately 10% at maximum. The major reasons of the difference are a void distribution over measurement area and an electrical insulation of the center electrode by bubbles. The principle and structure of this void fraction meter are very basic and simple. Therefore, the meter can be applied to various fields on gas-liquid two-phase flow studies. (author)

  7. Electro-optical equivalent calibration technology for high-energy laser energy meters

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Ji Feng, E-mail: wjfcom2000@163.com [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China); Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Graduate School of China Academy of Engineering Physics, Beijing 100088 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Chang, Yan; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China); Key Laboratory of Laser Science and Technology, China Academy of Engineering Physics, Mianyang 621900 (China); Sun, Li Qun [State Key Laboratory of Precision Measurement Technology and Instrument, Tsinghua University, Beijing 100084 (China)

    2016-04-15

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  8. Moisture dependence of positron annihilation rates in molecular substances

    International Nuclear Information System (INIS)

    Singh, J.J.; Holt, W.H.

    1982-01-01

    Positron annihilation rates have been studied in polymers and graphite-polymer composites as a function of their moisture content. The annihilation rates have been found to increase linearly with increasing moisture content in epoxies and polyamides, whereas no definite trends have been observed in polyimides. These experimental results have been used as the basis for the calculation of moisture content of several polymeric test specimens. For example, the directly measured moisture content of a Kevlar specimen was 45.5 + or - 5.0% of saturation value, whereas the moisture content on the basis of the decrease in positron lifetime was calculated to be 46.5 + or - 3.5%. Similarly, the directly measured moisture content of a graphite-epoxy composite (55 v/o fiber) was 19.2 + or - 0.6% of saturation value as opposed to a calculated value of 16.0 + or - 5.0%

  9. A neutron moisture system on nickel mineral transport rubber belt

    International Nuclear Information System (INIS)

    Jia Wenbao; Su Tongling; Zhang Xiaomin

    2000-01-01

    A method of density-thickness joint compensation was developed to make the on-line measurement of moisture for moving irregular mineral materials. At the same time, the materials' thickness, as a weighted factor, was chosen to modify the prompt moisture in a fixed time and improve the accuracy of measuring moisture. The experimental data show that the measurement accuracy is better than 5% for a thickness of > 2 cm and a moisture of > 6%. The system has been running on the spot for about three months, with a result accorded with that by the stoving-weighing method

  10. Soil moisture estimation using reflected solar and emitted thermal infrared radiation

    Science.gov (United States)

    Jackson, R. D.; Cihlar, J.; Estes, J. E.; Heilman, J. L.; Kahle, A.; Kanemasu, E. T.; Millard, J.; Price, J. C.; Wiegand, C. L.

    1978-01-01

    Classical methods of measuring soil moisture such as gravimetric sampling and the use of neutron moisture probes are useful for cases where a point measurement is sufficient to approximate the water content of a small surrounding area. However, there is an increasing need for rapid and repetitive estimations of soil moisture over large areas. Remote sensing techniques potentially have the capability of meeting this need. The use of reflected-solar and emitted thermal-infrared radiation, measured remotely, to estimate soil moisture is examined.

  11. Assessment of Multi-frequency Electromagnetic Induction for Determining Soil Moisture Patterns at the Hillslope Scale

    Science.gov (United States)

    Tromp-van Meerveld, I.; McDonnell, J.

    2009-05-01

    We present an assessment of electromagnetic induction (EM) as a potential rapid and non-invasive method to map soil moisture patterns at the Panola (GA, USA) hillslope. We address the following questions regarding the applicability of EM measurements for hillslope hydrological investigations: (1) Can EM be used for soil moisture measurements in areas with shallow soils?; (2) Can EM represent the temporal and spatial patterns of soil moisture throughout the year?; and (3) can multiple frequencies be used to extract additional information content from the EM approach and explain the depth profile of soil moisture? We found that the apparent conductivity measured with the multi-frequency GEM-300 was linearly related to soil moisture measured with an Aqua-pro capacitance sensor below a threshold conductivity and represented the temporal patterns in soil moisture well. During spring rainfall events that wetted only the surface soil layers the apparent conductivity measurements explained the soil moisture dynamics at depth better than the surface soil moisture dynamics. All four EM frequencies (7290, 9090, 11250, and 14010 Hz) were highly correlated and linearly related to each other and could be used to predict soil moisture. This limited our ability to use the four different EM frequencies to obtain a soil moisture profile with depth. The apparent conductivity patterns represented the observed spatial soil moisture patterns well when the individually fitted relationships between measured soil moisture and apparent conductivity were used for each measurement point. However, when the same (master) relationship was used for all measurement locations, the soil moisture patterns were smoothed and did not resemble the observed soil moisture patterns very well. In addition, the range in calculated soil moisture values was reduced compared to observed soil moisture. Part of the smoothing was likely due to the much larger measurement area of the GEM-300 compared to the Aqua

  12. Influence of the operating pressure in flow metering systems using turbine meters-key factors; Influencia da pressao em sistemas de medicao de gas natural com totalizadores de volume do tipo turbina: fatores a considerar

    Energy Technology Data Exchange (ETDEWEB)

    Wilcek, Alanna; Picanco, Marco Antonio S. [Companhia de Gas de Santa Catarina (SCGAS), Florianopolis, SC (Brazil)

    2008-07-01

    Flow measurement is a strategic process in the Natural Gas transport and distribution industry. The diary measurement of the 43 million cubic meters consumed in Brazil is made by flow meters certified by the Rede Brasileira de Calibracao (Brazilian Calibration Network) and INMETRO. Turbine flow meters are commonly applied in high flow measurement systems. Some manufactures and authors discuss the sensibility of turbine meters to the operational conditions. The objective of this paper is to establish a discussion about the flow pressure effects in the turbine meter and the influence in measure errors. (author)

  13. Measurement of complex RF susceptibility using a series Q-meter

    International Nuclear Information System (INIS)

    Kisselev, Yu.F.; Dulya, C.M.; Niinikoski, T.O.

    1995-01-01

    In this paper we have for the first time derived closed form expressions for the nuclear magnetic susceptibility in terms of the series Q-meter output voltage. We discuss the corrections involved in determining nuclear polarization from NMR signals by using the deuteron and proton spin systems as examples. Deuteron signals are shown to exhibit a false asymmetry, while proton signals have substantial shape distortions. Moreover, for the first time the importance of making a phase correction is demonstrated. We conclude that the series Q-meter with real part detection is not sufficient to produce an output voltage from which the nuclear susceptibility can be determined. An additional phase-sensitive detector is proposed for obtaining the imaginary part of the signal required for unambiguous extraction of the complex RF susceptibility. ((orig.))

  14. Advanced Metering Installations – A Perspective from Federal Sites

    Energy Technology Data Exchange (ETDEWEB)

    Earni, Shankar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Energy Technologies Area

    2016-05-02

    This report is intended to provide guidance to the United States Department of Energy (DOE) and other federal agencies to highlight some of the existing practices related to advanced building metering systems. This study identified some of the existing actions related to advanced meter data and proposes how advanced metered data can be employed to develop robust cost effective measurement and verification (M&V) strategies. This report proposes an integrated framework on how advanced meter data can be used to identify energy conservation opportunities and to develop proactive M&V strategies to ensure that the savings for energy projects are being realized. This information will help improve metering, feedback, and dashboard implementations for reducing energy use at DOE facilities, based on lessons learned from various advanced metering implementations.

  15. Response of bacteria in wastewater sludge to moisture loss by evaporation and effect of moisture content on bacterial inactivation by ionizing radiation

    International Nuclear Information System (INIS)

    Ward, R.L.; Yeager, J.G.; Ashley, C.S.

    1981-01-01

    Two studies were carried out to determine the influence of moisture content on the survival of bacteria in raw wastewater sludge. The first study involved the effect of water loss by evaporation on the bacterial population. The second used these dewatered samples to measure the effects of moisture content on the inactivation of bacteria in sludge by ionizing radiation. Both studies involved survival measurements of six representative fecally associated bacteria grown separately in sterilized sludge as well as survival data on bacteria indigenous to sludge. Growth of bacteria was stimulated in sludge during the initial phase of moisture removal by evaporation, but the reduction of moisture content below about 50% by weight caused a proportional decrease in bacterial numbers. The rates of inactivation of bacteria by ionizing radiation in sludge were usually modified to some degree by variations in moisture content. Most bacteria were found to be somewhat protected from ionizing radiation at reduced moisture levels

  16. Moisture dependence of positron annihilation rates in molecular substances

    International Nuclear Information System (INIS)

    Singh, J.J.; Holt, W.H.; Mock, W. Jr.

    1982-01-01

    Positron annihilation rates have been studied in polymers and graphite-polymer composites as a function of their moisture content. The annihilation rates have been found to increase linearly with increasing moisture content in epoxies and polyamides, whereas no definite trends have been observed in the polymides. These experimental results have been used as the basis for the calculation of moisture content of several polymeric test specimens. For example, the directly measured moisture content of a Kevlar/epoxy specimen (55 v/o fiber) was 45.5 +- 5.0% of saturation value, whereas the moisture content on the basis of the decrease in positron lifetime was calculated to be 46.5 +- 3.5%. Similarly, the directly measured moisture content of a graphite/epoxy composite (55 v/o fiber) was 19.2 +- 0.6% of saturation value as opposed to a calculated value of 16.0 +- 5.0%. (orig.)

  17. Irrigation scheduling using soil moisture sensors

    Science.gov (United States)

    Soil moisture sensors were evaluated and used for irrigation scheduling in humid region. Soil moisture sensors were installed in soil at depths of 15cm, 30cm, and 61cm belowground. Soil volumetric water content was automatically measured by the sensors in a time interval of an hour during the crop g...

  18. Multiangular L-band Datasets for Soil Moisture and Sea Surface Salinity Retrieval Measured by Airborne HUT-2D Synthetic Aperture Radiometer

    Science.gov (United States)

    Kainulainen, J.; Rautiainen, K.; Seppänen, J.; Hallikainen, M.

    2009-04-01

    SMOS is the European Space Agency's next Earth Explorer satellite due for launch in 2009. It aims for global monitoring of soil moisture and ocean salinity utilizing a new technology concept for remote sensing: two-dimensional aperture synthesis radiometry. The payload of SMOS is Microwave Imaging Radiometer by Aperture Synthesis, or MIRAS. It is a passive instrument that uses 72 individual L-band receivers for measuring the brightness temperature of the Earth. From each acquisition, i.e. integration time or snapshot, MIRAS provides two-dimensional brightness temperature of the scene in the instrument's field of view. Thus, consecutive snapshots provide multiangular measurements of the target once the instrument passes over it. Depending on the position of the target in instrument's swath, the brightness temperature of the target at incidence angles from zero up to 50 degrees can be measured with one overpass. To support the development MIRAS instrument, its calibration, and soil moisture and sea surface salinity retrieval algorithm development, Helsinki University of Technology (TKK) has designed, manufactured and tested a radiometer which operates at L-band and utilizes the same two-dimensional methodology of interferometery and aperture synthesis as MIRAS does. This airborne instrument, called HUT-2D, was designed to be used on board the University's research aircraft. It provides multiangular measurements of the target in its field of view, which spans up to 30 degrees off the boresight of the instrument, which is pointed to the nadir. The number of independent measurements of each target point depends on the flight speed and altitude. In addition to the Spanish Airborne MIRAS demonstrator (AMIRAS), HUT-2D is the only European airborne synthetic aperture radiometer. This paper presents the datasets and measurement campaigns, which have been carried out using the HUT-2D radiometer and are available for the scientific community. In April 2007 HUT-2D participated

  19. Selected micrometeorological and soil-moisture data at Amargosa Desert Research Site, an arid site near Beatty, Nye County, Nevada, 1998-2000

    Science.gov (United States)

    Johnson, Michael J.; Mayers, Charles J.; Andraski, Brian J.

    2002-01-01

    Selected micrometeorological and soil-moisture data were collected at the Amargosa Desert Research Site adjacent to a low-level radioactive waste and hazardous chemical waste facility near Beatty, Nev., 1998-2000. Data were collected in support of ongoing research studies to improve the understanding of hydrologic and contaminant-transport processes in arid environments. Micrometeorological data include precipitation, air temperature, solar radiation, net radiation, relative humidity, ambient vapor pressure, wind speed and direction, barometric pressure, soil temperature, and soil-heat flux. All micrometeorological data were collected using a 10-second sampling interval by data loggers that output daily mean, maximum, and minimum values, and hourly mean values. For precipitation, data output consisted of daily, hourly, and 5-minute totals. Soil-moisture data included periodic measurements of soil-water content at nine neutron-probe access tubes with measurable depths ranging from 5.25 to 29.75 meters. The computer data files included in this report contain the complete micrometeorological and soil-moisture data sets. The computer data consists of seven files with about 14 megabytes of information. The seven files are in tabular format: (1) one file lists daily mean, maximum, and minimum micrometeorological data and daily total precipitation; (2) three files list hourly mean micrometeorological data and hourly precipitation for each year (1998-2000); (3) one file lists 5-minute precipitation data; (4) one file lists mean soil-water content by date and depth at four experimental sites; and (5) one file lists soil-water content by date and depth for each neutron-probe access tube. This report highlights selected data contained in the computer data files using figures, tables, and brief discussions. Instrumentation used for data collection also is described. Water-content profiles are shown to demonstrate variability of water content with depth. Time-series data are

  20. Development of a novel vortex flow meter for downhole use

    NARCIS (Netherlands)

    Schiferli, W.; Cheng, L.K.

    2008-01-01

    Due to the increasing complexity of oil and gas wells, the demand for instrumentation to measure conditions inside well tubing below the surface is growing rapidly. A robust meter was designed to measure liquid flows at downhole conditions. The meter is based on a specially-designed bluff body to

  1. BCM6: New Generation of Boron Meter

    International Nuclear Information System (INIS)

    Pirat, P.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of boron meter, based on more than 30 years of experience. The Rolls-Royce BCM6 boron meter provides Nuclear Power Plant (NPP) operators with the boron concentration of the primary circuit. The meter provides continuous and safe measurements with no manual sampling and no human contact. In this paper, technical features, advantages and customer benefits of the use of the new generation of Rolls-Royce BCM6 boron meter will be detailed. Values and associated alarms are provides over different media: 4-20 mA outputs, relays, displays in the main control room and in the chemical lab, and digital links. A special alarm avoids unexpected homogeneous dilution of the primary circuit, which is a critical operational parameter. The Rolls-Royce BCM6 boron meter is fully configurable over a set of parameters allowing adaptation to customer needs. It has a differential capability, thus eliminating neutronic noise and keeping measurements accurate, even in the case of fuel clad rupture. Measurements are accurate, reliable, and have a quick response time. Equipment meets state-of-the-art qualification requests. Designed in 2008, the BCM6 boron meter is the newest equipment of Rolls-Royce boron meters product line. It has been chosen to equip the French EPR NPP and complies with the state-of-the-art of the technology. Rolls-Royce has more than 30 years of experience in Instrumentation and Controls with more than 75 NPP units operating worldwide. All of this experience return has been put in this new generation of equipment to provide the customer with the best operation. About Rolls-Royce Rolls-Royce is a global business providing integrated power systems for use on land, at sea and in the air. The Group has a balanced business portfolio with leading market positions. Rolls-Royce has a broad range of civil nuclear expertise, including work related to licensing and safety reviews, engineering design

  2. Ammonia concentrations in canine whole blood, EDTA-anticoagulated whole blood, and plasma measured by use of a point-of-care ammonia meter.

    Science.gov (United States)

    Odunayo, Adesola; Tobias, Karen M; Okafor, Chika C; Flatland, Bente

    2017-11-01

    OBJECTIVE To investigate the use of canine whole blood (WB) for measurement of ammonia concentration by use of a point-of-care ammonia meter and to compare results of measuring ammonia concentrations in WB, EDTA-anticoagulated WB, and plasma. ANIMALS 40 client-owned dogs. PROCEDURES A blood sample (2 mL) was obtained from each dog. One drop of WB was immediately applied to a test strip for evaluation with an ammonia meter. The remainder of the blood sample was placed in an EDTA-containing tube, and 1 drop of EDTA-anticoagulated WB was applied to a test strip. The remaining EDTA-anticoagulated WB sample was centrifuged, and the plasma was harvested and placed on ice. One drop of plasma was applied to a test strip; the remainder of the plasma sample was transported on ice and used for ammonia measurement with a reference laboratory instrument. All samples were tested within 1 hour after sample collection. Results were evaluated to detect significant differences in ammonia concentration. RESULTS Ammonia concentrations did not differ significantly between WB and EDTA-anticoagulated WB and between plasma samples measured with the meter and reference laboratory instrument. However, median ammonia concentration was significantly higher in plasma than in WB or EDTA-anti-coagulated WB. CONCLUSIONS AND CLINICAL RELEVANCE Anticoagulant-free WB was a valid sample for measurement by use of the ammonia meter. Plasma samples had higher ammonia concentrations than did WB samples. Results for each sample type should be interpreted by use of specimen- and method-specific reference intervals.

  3. Investigating water meter performance in developing countries: A ...

    African Journals Online (AJOL)

    High levels of water losses in distribution systems are the main challenge that water utilities in developing countries currently face. The water meter is an essential tool for both the utility and the customers to measure and monitor consumption. When metering is inefficient and coupled with low tariffs, the financial ...

  4. Soil moisture content with global warming

    International Nuclear Information System (INIS)

    Vinnikov, K.Ya.

    1990-01-01

    The potential greenhouse-gas-induced changes in soil moisture, particularly the desiccation of the Northern Hemisphere contents in summer, are discussed. To check the conclusions based on climate models the authors have used long-term measurements of contemporary soil moisture in the USSR and reconstructions of soil moisture for the last two epochs that were warmer than the present, namely, the Holocene optimum, 5,000-6,000 years ago, and the last interglacial, about 125,000 years ago. The analysis shows that there is a considerable disagreement between the model results and the empirical data

  5. 77 FR 40586 - Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter...

    Science.gov (United States)

    2012-07-10

    ...-01] Draft NIST Interagency Report (NISTIR) 7823, Advanced Metering Infrastructure Smart Meter... Technology (NIST) seeks comments on Draft NISTIR 7823, Advanced Metering Infrastructure Smart Meter... conformance test requirements for the firmware upgradeability process for the Advanced Metering Infrastructure...

  6. NEC Hazardous classification and compliance regarding the surface moisture monitor measurement system

    International Nuclear Information System (INIS)

    Bussell, J.H.

    1996-01-01

    The National Electrical Code, NFPA 70, and National Fire Protection Association requirements for use of Surface Moisture Monitor Systems in classified locations are discussed. The design and configuration of the surface moisture monitor are analyzed with respect to how they comply with requirements of the National Electrical Code requirements, articles 500-504

  7. Crop yield monitoring in the Sahel using root zone soil moisture anomalies derived from SMOS soil moisture data assimilation

    Science.gov (United States)

    Gibon, François; Pellarin, Thierry; Alhassane, Agali; Traoré, Seydou; Baron, Christian

    2017-04-01

    West Africa is greatly vulnerable, especially in terms of food sustainability. Mainly based on rainfed agriculture, the high variability of the rainy season strongly impacts the crop production driven by the soil water availability in the soil. To monitor this water availability, classical methods are based on daily precipitation measurements. However, the raingauge network suffers from the poor network density in Africa (1/10000km2). Alternatively, real-time satellite-derived precipitations can be used, but they are known to suffer from large uncertainties which produce significant error on crop yield estimations. The present study proposes to use root soil moisture rather than precipitation to evaluate crop yield variations. First, a local analysis of the spatiotemporal impact of water deficit on millet crop production in Niger was done, from in-situ soil moisture measurements (AMMA-CATCH/OZCAR (French Critical Zone exploration network)) and in-situ millet yield survey. Crop yield measurements were obtained for 10 villages located in the Niamey region from 2005 to 2012. The mean production (over 8 years) is 690 kg/ha, and ranges from 381 to 872 kg/ha during this period. Various statistical relationships based on soil moisture estimates were tested, and the most promising one (R>0.9) linked the 30-cm soil moisture anomalies from mid-August to mid-September (grain filling period) to the crop yield anomalies. Based on this local study, it was proposed to derive regional statistical relationships using 30-cm soil moisture maps over West Africa. The selected approach was to use a simple hydrological model, the Antecedent Precipitation Index (API), forced by real-time satellite-based precipitation (CMORPH, PERSIANN, TRMM3B42). To reduce uncertainties related to the quality of real-time rainfall satellite products, SMOS soil moisture measurements were assimilated into the API model through a Particular Filter algorithm. Then, obtained soil moisture anomalies were

  8. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland); Vehvilaeinen, S [Mittrix Oy (Finland); Rantanen, J [Helsinki Energy Board (Finland)

    1998-08-01

    In this chapter the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customers or their automation systems. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems it is possible to go there with a portable quality meter that is suitable for the case and inspect the situation. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This article also presents a prototype of such a quality monitoring kWh-meter. Dynamic tariffs and free electricity markets require two way communication with the utility and the customer and measurement of the time variations of the energy consumption. The customers or their energy management system must receive the energy prices from the utility and calculate the energy costs and decide upon the energy consumption control actions. Some alternative ways to meet these customer interface requirements are compared. Remote reading of kWh-meters requires a certain investment in meters and their data communication with the utility. Because smart meters can have some additional memory and calculating capacity and are capable of measuring various electric quantities, it is possible to share the costs with other applications that use the same hardware and data

  9. An introduction to NH-A neutron earth base moisture gage

    International Nuclear Information System (INIS)

    Zhu Huaian; Jiang Yulan; Yin Xilin; Yu Peiying; Luo Pinjie

    1988-01-01

    NH-A neutron earth base moisture gage is an accurate instrument which can measure earth moisture rapidly and non-destructively and display moisture results immediately. The deviation is estimated at ±0.012g/cm

  10. Performance Analysis of Secure and Private Billing Protocols for Smart Metering

    Directory of Open Access Journals (Sweden)

    Tom Eccles

    2017-11-01

    Full Text Available Traditional utility metering is to be replaced by smart metering. Smart metering enables fine-grained utility consumption measurements. These fine-grained measurements raise privacy concerns due to the lifestyle information which can be inferred from the precise time at which utilities were consumed. This paper outlines and compares two privacy-respecting time of use billing protocols for smart metering and investigates their performance on a variety of hardware. These protocols protect the privacy of customers by never transmitting the fine-grained utility readings outside of the customer’s home network. One protocol favors complexity on the trusted smart meter hardware while the other uses homomorphic commitments to offload computation to a third device. Both protocols are designed to operate on top of existing cryptographic secure channel protocols in place on smart meters. Proof of concept software implementations of these protocols have been written and their suitability for real world application to low-performance smart meter hardware is discussed. These protocols may also have application to other privacy conscious aggregation systems, such as electronic voting.

  11. Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement

    Science.gov (United States)

    Hamdollahi, Hassan; Rahbar-Shahrouzi, Javad

    2018-05-01

    In this paper, a cantilever-type flow meter was fabricated to measure the rate of air flow in turbulent subsonic regimes such as purged gases. In the fabrication process, a piezoresistive material was coated on an interdigitated electric board as a substrate. The piezoresistive layer was a blend of latex as the polymeric matrix and graphene oxide as the sensing nanomaterial agent, which was reduced by solvothermal reduction method. The piezoresistive blend was dip-coated on a substrate with dotted pattern and was then reduced at 240 °C for 1 h in every coating step. When an air flow passed over the surface of the cantilever beam, the beam was bent in the downward direction, resulting in small variations in the resistance of the piezoresistive layer and a change in the bending angle of the cantilever which were measured simultaneously. The air flow rate was acquired via calibrating electrical resistance changes by Arduino and Wheatstone bridge circuit. The blending angle of the substrate caused by the interaction between the airflow and the cantilever and recorded by the camera and image processing was ultimately compared with the simulation results. The flow meter accuracy as a percentage of full scale (% FS) was calculated to be  ±5.8%, and mean deviation was equal to 2.1 (% FS) with the appropriate response time of 0.70 s at the air flow range of 100‑240 m s‑1. Highlights • A cantilever-type flow meter was fabricated to measure the high-speed air flow rate. • The sensitive piezoresistive material was composed of GO and latex. • The dip-coating method was used to deposit the piezoresistive layer on the fiberglass substrate. • The impact of effective parameters on the performance of the flow meter was investigated. • A simulation study was performed and the results were compared with the experimental data.

  12. Estimating soil moisture using the Danish polarimetric SAR

    DEFF Research Database (Denmark)

    Jiankang, Ji; Thomsen, A.; Skriver, Henning

    1995-01-01

    The results of applying data from the Danish polarimetric SAR (EMISAR) to estimate soil moisture for bare fields are presented. Fully calibrated C-band SAR images for hh, vv and cross polarizations have been used in this study. The measured surface roughness data showed that classical roughness a...... of surface parameters with the bilinear model, the correlation coefficient between the estimated and measured soil moisture, as well as rms height, is about 0.77. To improve the result, the local incidence angles need to be taken into account......The results of applying data from the Danish polarimetric SAR (EMISAR) to estimate soil moisture for bare fields are presented. Fully calibrated C-band SAR images for hh, vv and cross polarizations have been used in this study. The measured surface roughness data showed that classical roughness...... autocorrelation functions (Gaussian and Exponential) were not able to fit natural surfaces well. A Gauss-Exp hybrid model which agreed better with the measured data has been proposed. Theoretical surface scattering models (POM, IEM), as well as an empirical model for retrieval of soil moisture and surface rms...

  13. Using microcantilever sensors to measure poly(lactic-co-glycolic acid) plasticization by moisture uptake

    DEFF Research Database (Denmark)

    Alves, Gustavo Marcati A.; Bose-Goswami, Sanjukta; Mansano, Ronaldo D.

    2018-01-01

    Polymeric materials absorb water when exposed to humidity or in contact with aqueous solutions. The polymer and water molecules interact, changing the physicochemical parameters of the material; the most noticeable effect is a decreased glass transition temperature (Tg), known as plasticization. We...... used microcantilever sensors to measure the Tg versus moisture content in poly(lactic-co-glycolic acid) (PLGA), a biodegradable polymer used in implants and as a drug carrier. We demonstrate a concomitant measurement of the mass absorption and Tg using nanograms of material and an inexpensive setup...

  14. Smart meters. Smart metering. A solution module for a future-oriented energy system; Intelligente Zaehler. Smart Metering. Ein Loesungsbaustein fuer ein zukunftsfaehiges Energiesystem

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Nadia; Seidl, Hans [comps.

    2011-12-15

    The German Energy Agency GmbH (Berlin, Federal Republic of Germany) reports on smart metering as a solution module for a future-oriented energy system by means of the following contributions: (1) Key role for smart meters; (2) What is smart metering? (3) Implementation of smart metering in Europe; (4) The market development to date in Germany; (5) Practical experiences with smart metering in Germany; (6) Frequently asked questions; (7) Smart metering in intelligent networks; (8) Legal framework conditions; (9) Data security and data protection in the utilisation of smart meters; (10) Ongoing information; (11) Efficient energy systems.

  15. Automated Quality Control of in Situ Soil Moisture from the North American Soil Moisture Database Using NLDAS-2 Products

    Science.gov (United States)

    Ek, M. B.; Xia, Y.; Ford, T.; Wu, Y.; Quiring, S. M.

    2015-12-01

    The North American Soil Moisture Database (NASMD) was initiated in 2011 to provide support for developing climate forecasting tools, calibrating land surface models and validating satellite-derived soil moisture algorithms. The NASMD has collected data from over 30 soil moisture observation networks providing millions of in situ soil moisture observations in all 50 states as well as Canada and Mexico. It is recognized that the quality of measured soil moisture in NASMD is highly variable due to the diversity of climatological conditions, land cover, soil texture, and topographies of the stations and differences in measurement devices (e.g., sensors) and installation. It is also recognized that error, inaccuracy and imprecision in the data set can have significant impacts on practical operations and scientific studies. Therefore, developing an appropriate quality control procedure is essential to ensure the data is of the best quality. In this study, an automated quality control approach is developed using the North American Land Data Assimilation System phase 2 (NLDAS-2) Noah soil porosity, soil temperature, and fraction of liquid and total soil moisture to flag erroneous and/or spurious measurements. Overall results show that this approach is able to flag unreasonable values when the soil is partially frozen. A validation example using NLDAS-2 multiple model soil moisture products at the 20 cm soil layer showed that the quality control procedure had a significant positive impact in Alabama, North Carolina, and West Texas. It had a greater impact in colder regions, particularly during spring and autumn. Over 433 NASMD stations have been quality controlled using the methodology proposed in this study, and the algorithm will be implemented to control data quality from the other ~1,200 NASMD stations in the near future.

  16. Passive microwave remote sensing of soil moisture

    International Nuclear Information System (INIS)

    Jackson, T.J.; Schmugge, T.J.

    1986-01-01

    Microwave remote sensing provides a unique capability for direct observation of soil moisture. Remote measurements from space afford the possibility of obtaining frequent, global sampling of soil moisture over a large fraction of the Earth's land surface. Microwave measurements have the benefit of being largely unaffected by cloud cover and variable surface solar illumination, but accurate soil moisture estimates are limited to regions that have either bare soil or low to moderate amounts of vegetation cover. A particular advantage of passive microwave sensors is that in the absence of significant vegetation cover soil moisture is the dominant effect on the received signal. The spatial resolutions of passive microwave soil moisture sensors currently considered for space operation are in the range 10–20 km. The most useful frequency range for soil moisture sensing is 1–5 GHz. System design considerations include optimum choice of frequencies, polarizations, and scanning configurations, based on trade-offs between requirements for high vegetation penetration capability, freedom from electromagnetic interference, manageable antenna size and complexity, and the requirement that a sufficient number of information channels be available to correct for perturbing geophysical effects. This paper outlines the basic principles of the passive microwave technique for soil moisture sensing, and reviews briefly the status of current retrieval methods. Particularly promising are methods for optimally assimilating passive microwave data into hydrologic models. Further studies are needed to investigate the effects on microwave observations of within-footprint spatial heterogeneity of vegetation cover and subsurface soil characteristics, and to assess the limitations imposed by heterogeneity on the retrievability of large-scale soil moisture information from remote observations

  17. Glucose meters: evaluation of the new formulation measuring strips from Roche (Accu-Chek) and Abbott (MediSense).

    Science.gov (United States)

    Dimeski, G; Jones, B W; Tilley, V; Greenslade, M N; Russell, A W

    2010-07-01

    Both Roche and Abbott have released new glucose meter strips. They supply the entire Australian hospital market. The present study compared the performance of the new strips utilizing various specimen types (capillary, venous lithium heparin whole blood, venous lithium heparin plasma and serum) and evaluated how well they comply with the International Standards Organization (ISO) 15197 criteria. The study included imprecision, patient comparison and interference studies. Participants with and without diabetes were recruited to evaluate the performance of various specimen types against the Beckman DxC800 glucose method. The strips were tested for different interferences: galactose, maltose, lactose, Icodextrin, Intragam, paracetamol, sodium, ascorbic acid, variable strip storage temperature, haematocrit, haemolysis and lipaemia. The imprecision of the two strips was approximately 5% or less, except for the Abbott strip at very low values (1.4 mmol/L), approximately 7%. In total, 78% and 84%, respectively, of the results from the finger prick capillary specimens with the Roche (Accu-Chek Performa meter) and Abbott (Optium Xceed meter) strips, not 95% or greater as recommended by the ISO guideline, were within the recommended limits compared with reference plasma estimation on laboratory analysers. Galactose, ascorbic acid, haematocrit and sodium on the Roche and ascorbic acid and haematocrit on the Abbott strip continue to interfere to a variable degree with the glucose measurement. Analytically small differences exist between the glucose meter strips. The most significant analytical difference with the strips was at low glucose levels when compared with laboratory analyses and this may be of clinical importance. The impact of some of the interferences is variable between the two strips. Individuals, health-care professionals and health-care institutions should consider these data when selecting glucose meters for the management of people with diabetes mellitus.

  18. β-ray scintillation survey meter for small-sized pipes

    International Nuclear Information System (INIS)

    Yamano, Toshiya; Suzuki, Toshikazu; Yoshida, Yoshiteru; Higashidate, Takamichi; Yonemura, Kenji; Fujita, Michio.

    1990-01-01

    The outer surface of the small-sized pipes used as scaffolding is measured by beta/gamma survey meter when they are carried out from the controlled area in nuclear facilities. But, the measurement of the radioactive contamination on the inner surface, when it is needed, is done indirectly using the smear method. To improve these vexatious works, Fuji Electric Co., Ltd. and Chubu Electric Power Co., Inc. jointly developed a beta-ray scintillation survey meter which, when inserted directly into pipes, can detect radioactive contamination on the inner surface. This detector is made of cylindrical plastic scintillator and it can measure low energy beta-ray by using the coincidence method which reduces random noise. A field test carried out with this prototype survey meter brought favorable results for designing its final version. (author)

  19. Analysis of Moisture Evaporation from Underwear Designed for Fire-Fighters

    Directory of Open Access Journals (Sweden)

    Elena Onofrei

    2015-03-01

    Full Text Available In this study we analysed the effect of moisture on the thermal protective performance of fire-fighter clothing in case of routine fire-fighting conditions. In the first stage of this research we investigated simultaneous heat and moisture transfer through a single-layer fabric, used as underwear for fire-fighters, at different moisture conditions. In the second stage of the study, the underwear in dry and wet state was tested together with protective clothing systems for fire-fighter consisting of three or four layers. It was found that during the evaporation of the moisture, a temperature plateau appeared during which temperatures hardly rose. The energy consumption used for the phase change of moisture located in the assembly dominated the heat transfer process as long as there was moisture present. As soon as all water had evaporated, the temperatures approached the temperatures measured for dry samples. The moisture within the clothing assembly did not lead to increased temperatures compared with the measurements with dry samples. This research has confirmed that moisture can positively affect the thermal protection of a clothing system.

  20. Investigation and Comparison of Separate Meter-In Separate Meter-Out Control Strategies

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Andersen, Torben Ole; Skoubo, Tobias

    2014-01-01

    In the later years, there has been an increased focus on new valve types, which yield the possibility to do Separate Meter-In Separate Meter-Out (SMISMO) control. This includes both digital valves, but proportional valves with separate metering spools and build in pressure sensors are also emerging....... The possibility to independently control the meter-in and meter-out side not only increase the functionality of the system, but also opens up for better performance and/or lowered energy consumption. The focus of the current paper is therefore on investigation and comparison of what may be obtained using...

  1. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  2. Beyond revenue metering -- a new age for automatic meter reading

    Energy Technology Data Exchange (ETDEWEB)

    Chebra, R. J. [RJC Consulting L.L.C., PQ (Canada)

    2002-10-01

    Advanced metering, data management, and communications possibilities of automated meter reading are explored. Applications in the area of demand side management, including load reduction, peak shaving and load shifting, new tariff structures based on the 'time of use incentive/penalty' approach, and information grade metering are emphasized. Based on trends and expectations, it is predicted that AMR will continue to experience rapid growth and deployment as new services are made available to the mass market. For example, technological advances will enable the industry to make 'time of use metering ' more attractive and beneficial to residential consumers, and embedded intelligence will make it possible to achieve more holistic energy environments.

  3. Proceedings of the 2006 smart metering conference and expo

    International Nuclear Information System (INIS)

    2006-01-01

    Ontario's smart metering program was launched as part of a general demand response management strategy to improve energy conservation in the province. Smart metering will help consumers to control their electricity bills through conservation and demand response, and will allow consumers to better manage their energy consumption and use it more effectively during cheaper, off-peak times of day. Smart metering systems measure how much electricity a customer uses on an hourly basis, and data is transferred daily to local electricity distributors. Toronto Hydro will have close to 200,000 smart meters installed by the end of 2006. By 2010, Toronto will be North America's largest urban centre to have made the full transition to smart metering technology across its entire base. This conference provided an update of Toronto Hydro's smart metering project, as well as details of their demand response program. Presentations were given by a variety of experts in information technology as well as electric power industry leaders North American demand and response metering strategies were reviewed, as well as various initiatives in advanced metering infrastructure (AMI). Security risks associated with smart metering environments were reviewed. An evaluation of the current regulatory environment was presented along with a discussion of smart metering standards and compatibility issues. New metering technologies were presented as well as various associated demand side management tools. Smart metering pilot programs and initiatives were discussed, and best practices in smart metering were evaluated. Twenty-nine presentations were given at the conference, 13 of which have been indexed separately for inclusion in this database. refs., tabs., figs

  4. Measurements of moisture content in wood fuels with dual energy x-ray; Maetning av fukt i biobraenslen med dubbelenergiroentgen

    Energy Technology Data Exchange (ETDEWEB)

    Nordell, Anders [Industriellt Utvecklingscentrum i Karlskoga, Karlskoga (Sweden); Vikterloef, K J [Oerebro Radiofysik AB, Oerebro (Sweden)

    2000-04-01

    Good methods enabling quick determination of moisture in wood fuels are lacking. A standardized method generally used by the biofuel industry means drying samples in furnaces during at least 16 hours. The idea of this work has been to investigate if x-ray technique can offer a superior alternative for fast moisture determination. Analysis with x-ray has many advantages. The x-rays go completely through the whole test specimen. Large samples or many sequential samples can rapidly be measured. The penetration is extraordinary good; all parts of the tested mass will be analyzed. The measurement relies on the absorption of gamma photons in the tested mass. The x-ray absorption is carried out deep down in the atoms and therefore is independent of the materials equation of state as temperature, grain size or molecule binding. The disadvantages of the method are the general anxiety which can be for gamma rays, the relative high cost for equipment and the fact that an x-ray tube will wear with time and needs replacement. The method used here for moisture measurement is known as dual energy x-ray. The test sample is simultaneously exposed to transmission of two separate x-ray energies. The two energies are absorbed differently by the sample. The ratio of the absorption in the two respective energies is calculated and from that conclusions on the composition of the material can be drawn. The equipment used in this test is a standard medical apparatus adapted for the study of human body composition. When instead used for measurements of moisture in wood material the discrimination signal is about half of that achieved in the normal medical case. Despite that, the signal has been good enough for giving satisfactory accuracy in the moisture estimation. A little more than sixty approved results are presented in the report comprehending ten different fuel types. The results are grouped into three main categories depending on fuel type, wood fuels, peat fuels and salix including

  5. KVP meter errors induced by plastic wrap

    International Nuclear Information System (INIS)

    Jefferies, D.; Morris, J.W.; White, V.P.

    1991-01-01

    The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model number-sign 90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique

  6. Measuring geomechanical properties of Topopah Spring Tuff at the 1-meter scale

    International Nuclear Information System (INIS)

    Blair, S.C.; Berge, P.A.

    1994-11-01

    The Yucca Mountain Site Characterization Project is studying physical and chemical properties of Topopah Spring tuff and coupled thermal, mechanical, hydrological, and geochemical processes expected in the near-field environment of the potential waste repository at Yucca Mountain, Nevada. Investigating the suitability of Topopah Spring tuff as a host rock for radioactive waste disposal includes measuring mechanical properties. Since heterogeneities vary with scale, from vugs and cracks at the hand-sample scale to fractures and vertical variations in degree of welding at the outcrop scale, mechanical properties of the tuff depend on scale. The Lawrence Livermore National Laboratory has planned a Large Block Test (LBT) to investigate rock mass properties and coupled processes at elevated temperatures in Topopah Spring tuff at the scale of a few meters. This paper describes planned laboratory experiments in support of the LBT, to measure elastic properties and mechanical behavior of Topopah Spring tuff at the scale of a few cm to 1 m. The laboratory experiments will include measurement of stress-strain behavior, acoustic emissions during heating, and elastic wave velocities in small blocks of tuff

  7. Assessment of the implementation regulations for smart meters; Beoordeling uitvoeringsregelingen Slimme Meter

    Energy Technology Data Exchange (ETDEWEB)

    Boekema, J.

    2011-03-15

    TNO (Netherlands) assessed whether the smart meter is reliable and future proof. By request of the Dutch Ministry of Economic Affairs, Agriculture and Innovation (ELI) an assessment was conducted of the requirements for smart meters and, as formulated in the Order in Council 'Decree on remotely readable metering devices', based on 48 tests regarding security, privacy and future stability. Taking into account a number of described recommendations, TNO deems the legislation and implementation schemes sufficient to allow for safe, reliable and future proof implementation of smart meters in the Netherlands. [Dutch] TNO heeft beoordeeld of de slimme meter betrouwbaar en toekomstvast is. Ten behoeve van het ministerie van Economische Zaken, Landbouw en Innovatie (ELI) zijn de eisen die aan slimme meters worden gesteld, en zoals verwoord in de AmvB 'Besluit op afstand uitleesbare meetinrichtingen', beoordeeld aan de hand van 48 toetsen over zekerheid (security), persoonlijke levenssfeer (privacy) en toekomstvastheid. Met inachtneming van een aantal omschreven aanbevelingen, vindt TNO wetgeving en uitvoeringsregelingen zodanig dat daarmee een veilige, betrouwbare en toekomstvaste slimme meter geimplementeerd kan worden in Nederland.

  8. The AGS Ggamma Meter and Calibrating the Gauss Clock

    Energy Technology Data Exchange (ETDEWEB)

    Ahrens, Leif [Brookhaven National Laboratory (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-03-31

    During AGS Polarized Proton acceleration periods, one output from the AGS Ggamma Meter, namely the energy (or Ggamma) calculated from the magnetic field in the AGS main magnets and the beam radius- both measured in particular instant, is used to figure out the times in the AGS magnet acceleration cycle when the beam passes through a particular set of depolarizing resonances. The resonance set occur whenever a particle’s Ggamma (energy*(G/m) becomes nearly equal to n*Qx (i.e. any integer multiplied by the horizontal betatron tune). This deliverable is why the machinery is referred to as the ''Ggamma Meter'' rather than the AGS energy meter. The Ggamma Meter takes as inputs a set of measurements of frequency (F(t)), radius (r(t)), and gauss clock counts (GCC(t)). The other energy (GgammaBr) assumes the field when the gauss clock starts counting is known. The change in field to time t is given by the measured accumulated gauss clock counts multiplied by the gauss clock calibration (gauss/GCC). In order to deal with experimental data, this calibration factor gets an added ad hoc complication, namely a correction dependent on the rate of change the counting rate. The Ggamma meter takes GCC(t) and together with the past history for this cycle calculates B(t).

  9. The AGS Ggamma Meter and Calibrating the Gauss Clock

    International Nuclear Information System (INIS)

    Ahrens, Leif

    2014-01-01

    During AGS Polarized Proton acceleration periods, one output from the AGS Ggamma Meter, namely the energy (or Ggamma) calculated from the magnetic field in the AGS main magnets and the beam radius- both measured in particular instant, is used to figure out the times in the AGS magnet acceleration cycle when the beam passes through a particular set of depolarizing resonances. The resonance set occur whenever a particle's Ggamma (energy*(G/m) becomes nearly equal to n*Qx (i.e. any integer multiplied by the horizontal betatron tune). This deliverable is why the machinery is referred to as the ''Ggamma Meter'' rather than the AGS energy meter. The Ggamma Meter takes as inputs a set of measurements of frequency (F(t)), radius (r(t)), and gauss clock counts (GCC(t)). The other energy (GgammaBr) assumes the field when the gauss clock starts counting is known. The change in field to time t is given by the measured accumulated gauss clock counts multiplied by the gauss clock calibration (gauss/GCC). In order to deal with experimental data, this calibration factor gets an added ad hoc complication, namely a correction dependent on the rate of change the counting rate. The Ggamma meter takes GCC(t) and together with the past history for this cycle calculates B(t).

  10. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    Energy Technology Data Exchange (ETDEWEB)

    Scogin, J. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-24

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  11. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    International Nuclear Information System (INIS)

    Scogin, J. H.

    2017-01-01

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  12. 40 CFR 86.1320-90 - Gas meter or flow instrumentation calibration; particulate, methanol, and formaldehyde measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Gas meter or flow instrumentation... Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures § 86.1320-90 Gas meter or flow..., methanol and formaldehyde emissions requires the use of gas meters or flow instrumentation to determine...

  13. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  14. Moisture transfer through the membrane of a cross-flow energy recovery ventilator: Measurement and simple data-driven modeling

    Science.gov (United States)

    CR Boardman; Samuel V. Glass

    2015-01-01

    The moisture transfer effectiveness (or latent effectiveness) of a cross-flow, membrane based energy recovery ventilator is measured and modeled. Analysis of in situ measurements for a full year shows that energy recovery ventilator latent effectiveness increases with increasing average relative humidity and surprisingly increases with decreasing average temperature. A...

  15. Free-Tropospheric Moisture Convergence and Tropical Convective Regimes

    Science.gov (United States)

    Masunaga, H.

    2014-12-01

    It is known that quiescent periods with only shallow cumuli prevalent are frequently observed even in the deep Tropics, which is considered from the climatological perspectives as an area harboring vigorous deep convection. It is argued in this work that the free-tropospheric (FT) moisture convergence is a crucial factor for separating the stable maintenance of isolated shallow cumuli in the quiescent periods from the self-sustaining growth of organized convective systems in the dynamic periods over tropical oceans. The analysis is based on a variety of satellite measurements including Aqua AIRS T and q soundings and QuikSCAT surface wind, composited with reference to the time before or after the occurrence of precipitating clouds detected by TRMM PR. The FT moisture convergence and updraft moisture flux at cloud base are then derived from this dataset under large-scale moisture budget constraint (see Figure). Free-tropospheric precipitation efficiency (FTPE), or the ratio of precipitation to updraft moisture flux at cloud base, is introduced as a measure of convective intensity (rather than the population) over the large-scale domain. The following hypothesis is discussed in light of the analysis results. Isolated shallow cumuli would stay shallow when large-scale FT moisture is diverging (although moisture is weakly converging when integrated over the whole troposphere) since an increase in cumulus population would be counteracted by an additional moisture divergence in the FT. When large-scale FT convergence is positive, in contrast, developing clouds would induce a more moisture input and allow an unstable growth to a highly organized convective system. Zero FT moisture convergence may serve as the neutrality separating the negative feedback acting in the quiescent regime from the positive feedback instrumental for the dynamic regime.

  16. Microprocessor controlled digital period meter

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1980-01-01

    A microprocessor controlled digital period meter has been developed and tested operationally on a reactor at Argonne National Laboratory. The principle of operation is the mathematical relationship between asymptotic periods and pulse counting circuitry. This relationship is used to calculate and display the reactor periods over a range of /plus or minus/1 second to /plus or minus/999 seconds. The time interval required to update each measurement automatically varies from 8 seconds at the lowest counting rates to 2 seconds at higher counting rates. The paper will describe hardware and software design details and show the advantages of this type of Period Meter over the conventional circuits. 1 ref

  17. Status of neutron monitoring meters for radiation protection purpose

    International Nuclear Information System (INIS)

    Li Taosheng

    2003-01-01

    The status of and trends towards the development of neutron monitoring meters, such as dose survey meter, workplace (ambient) spectrometer and individual dosimeters, are discussed in the present paper from the perspectives of workplace and individual dose monitoring. Over the past 4 decades, both neutron dose survey meter and workplace spectrometer have declined to be more reasonable in design of their probes, with more broaden applications. With the development of electronic technology, there is a trend towards being more small-compacted and smart. Although many technical difficulties in the practical measurement, some significant progresses have be made in the development and research of these kinds of meters. (authors)

  18. Design and Implementation of Enhanced Smart Energy Metering System

    Directory of Open Access Journals (Sweden)

    Oday A.L.A Ridha

    2017-03-01

    Full Text Available In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses. Moreover, it sends the switch off command in case of the consumer bill is not paid. For implementation of smart energy meter, the microcontroller (PIC 18F45K22 is used. For communication between billing center and smart energy meters, ZigBee technology is adopted. The necessary program for smart energy meter is written in MicroC PRO, while the program for billing center is written in visual C#.

  19. Uncertainty of Deardorff’s soil moisture model based on continuous TDR measurements for sandy loam soil

    Directory of Open Access Journals (Sweden)

    Brandyk Andrzej

    2016-03-01

    Full Text Available Knowledge on soil moisture is indispensable for a range of hydrological models, since it exerts a considerable influence on runoff conditions. Proper tools are nowadays applied in order to gain in-sight into soil moisture status, especially of uppermost soil layers, which are prone to weather changes and land use practices. In order to establish relationships between meteorological conditions and topsoil moisture, a simple model would be required, characterized by low computational effort, simple structure and low number of identified and calibrated parameters. We demonstrated, that existing model for shallow soils, considering mass exchange between two layers (the upper and the lower, as well as with the atmosphere and subsoil, worked well for sandy loam with deep ground water table in Warsaw conurbation. GLUE (Generalized Likelihood Uncertainty Estimation linked with GSA (Global Sensitivity Analysis provided for final determination of parameter values and model confidence ranges. Including the uncertainty in a model structure, caused that the median soil moisture solution of the GLUE was shifted from the one optimal in deterministic sense. From the point of view of practical model application, the main shortcoming were the underestimated water exchange rates between the lower soil layer (ranging from the depth of 0.1 to 0.2 m below ground level and subsoil. General model quality was found to be satisfactory and promising for its utilization for establishing measures to regain retention in urbanized conditions.

  20. Effect of Smart Meter Measurements Data On Distribution State Estimation

    DEFF Research Database (Denmark)

    Pokhrel, Basanta Raj; Nainar, Karthikeyan; Bak-Jensen, Birgitte

    2018-01-01

    in the physical grid can enforce significant stress not only on the communication infrastructure but also in the control algorithms. This paper aims to propose a methodology to analyze needed real time smart meter data from low voltage distribution grids and their applicability in distribution state estimation...

  1. Remote calibration system of a smart electrical energy meter

    Directory of Open Access Journals (Sweden)

    Zakariae Jebroni

    2017-12-01

    Full Text Available The need to control the power grid in real time has opened a new field of research, today researchers are trying to design electrical meters that are completely remote controlled, to create an advanced metering infrastructure. One of the most important processes in the field of measurement is the calibration of measuring instruments. The calibration process of the electrical meters was performed at laboratories. However, the new directives, now, require a regular test of accuracy. Nevertheless, moving each time on site to check the accuracy of a meter can be annoying. To solve this problem our contribution is to propose a new structure of a smart meter that integrates a calibration card, so that, this process is carried out remotely. To be able to calibrate the meter or test its accuracy, we have included an AC-AC converter powered by the electrical grid and that provides a stable voltage independent of the electrical grid in term of frequency and amplitude. The output voltage of the converter is used as the reference signal during calibration or accuracy testing. In this paper, we will present the structure of the calibration card, the study and dimensioning of the converter, as well as the control technique used to eliminate variations of the input voltage. At the end, we will present the results of simulations and experiments.

  2. A Novel Smart Meter Controlling System with Dynamic IP Addresses

    DEFF Research Database (Denmark)

    Manembu, Pinrolinvic; Welang, Brammy; Kalua Lapu, Aditya

    2017-01-01

    Smart meters are the electronic devices for measuring energy consumption in real time. Usually, static public IP addresses are allocated to realize the point-to-point (P2P) communication and remote controlling for smart metering systems. This, however, restricts the wide deployment of smart meters......, due to the deficiency of public IP resources. This paper proposes a novel subscription-based communication architecture for the support of dynamic IP addresses and group controlling of smart meters. The paper evaluates the proposed architecture by comparing the traditional P2P architecture...

  3. Soil Moisture Estimation Using MODIS Images (Case Study: Mashhad Plain Area

    Directory of Open Access Journals (Sweden)

    M. Fashaee

    2016-09-01

    Full Text Available Introduction: Numerous studies have been undertaken based on satellite imagery in order to estimate soil moisture using vegetation indices such as NDVI. Previous studies suffer from a restriction; these indices are not able to estimate where the vegetative coverage is low or where no vegetation exists. Hence, it is essential to develop a model which can overcome this restriction. Focus of this research is on estimation of soil moisture for low or scattered vegetative land covers. Trapezoidal temperature-vegetation (Ts~VI model is able to consider the status of soil moisture and vegetation condition. It can estimate plant water deficit for weak or no vegetation land cover. Materials and Methods: Moran proposed Water Deficit Index (WDI for evaluating field evapotranspiration rates and relative field water deficit for both full-cover and partially vegetated sites. The theoretical basis of this method is based on the energy balance equation. Penman-Monteith equation of energy balance was used to calculate the coordinates of the four vertices of the temperature-vegetation trapezoid also for four different extreme combinations of temperature and vegetation. For the (Ts−Ta~Vc trapezoid, four vertices correspond to 1 well-watered full-cover vegetation, 2 water-stressed full-cover vegetation, 3 saturated bare soil, and 4 dry bare soil. WDI is equal to 0 for well-watered conditions and equals to 1 for maximum stress conditions. As suggested by Moran et al. to draw a trapezoidal shape, some field measurements are required such as wind speed at the height of 2 meters, air pressure, mean daily temperature, vapor pressure-temperature curve slope, Psychrometrics constant, vapor pressure at mean temperature, vapor pressure deficit, external radiation, solar radiation of short wavelength, longwave radiation, net radiation, soil heat flux and air aerodynamic resistance is included. Crop vegetation and canopy resistance should be measured or estimated. The study

  4. Smart metering. Conformance tests for electricity meters; Smart Metering. Konformitaetstests an Stromzaehlern

    Energy Technology Data Exchange (ETDEWEB)

    Bormann, Matthias; Pongratz, Siegfried [VDE Pruef- und Zertifizierungsinstitut, Offenbach (Germany)

    2012-07-01

    Introduction of communication technologies into today's energy network enables the interworking between the domains of smart metering, smart grid, smart home and e-mobility as well as the creation and provisioning of new innovative services such as efficient load adjustment. Due to this convergence the new energy networks are becoming increasingly complex. Ensuring the interworking between all network elements (e.g. electricity meters, gateways) in these smart energy networks is of utmost importance. To this end conformance and interoperability tests have to be defined to ensure that services work as expected. (orig.)

  5. Quantitative estimation of the influence of external vibrations on the measurement error of a coriolis mass-flow meter

    NARCIS (Netherlands)

    van de Ridder, Bert; Hakvoort, Wouter; van Dijk, Johannes; Lötters, Joost Conrad; de Boer, Andries; Dimitrovova, Z.; de Almeida, J.R.

    2013-01-01

    In this paper the quantitative influence of external vibrations on the measurement value of a Coriolis Mass-Flow Meter for low flows is investigated, with the eventual goal to reduce the influence of vibrations. Model results are compared with experimental results to improve the knowledge on how

  6. Soil-moisture transport in arid site vadose zones

    International Nuclear Information System (INIS)

    Isaacson, R.E.; Brownell, L.E.; Nelson, R.W.; Roetman, E.L.

    1974-01-01

    Soil-moisture transport processes in the arid soils of the United States Atomic Energy Commission's Hanford site are being evaluated. The depth of penetration of meteoric precipitation has been determined by profiling fall-out tritium at two locations where the water table is about 90 m below ground surface. In situ temperatures and water potentials were measured with temperature transducers and thermocouple psychrometers at the same location to obtain thermodynamic data for identifying the factors influencing soil-moisture transport. Neutron probes are being used to monitor soil-moisture changes in two lysimeters, three metres in diameter by 20 metres deep. The lysimeters are also equipped to measure pressure, temperature and relative humidity as a function of depth and time. Theoretical models based on conservation of momentum expressions are being developed to analyse non-isothermal soil-moisture transport processes. Future work will be concerned with combining the theoretical and experimental work and determining the amount of rainfall required to cause migration of soil-moisture to the water table. (author)

  7. Radiofrequency fields associated with the Itron smart meter.

    Science.gov (United States)

    Tell, R A; Sias, G G; Vazquez, A; Sahl, J; Turman, J P; Kavet, R I; Mezei, G

    2012-08-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically smart meters as deployed. However, the results are restricted to a single manufacturer's emitters.

  8. Determination of the Ability to Measure Traces of Water in Dehydrated Residues of Waste Water by IR Diffuse Reflectance Spectra

    Science.gov (United States)

    Pratsenka, S. V.; Voropai, E. S.; Belkin, V. G.

    2018-01-01

    Rapid measurement of the moisture content of dehydrated residues is a critical problem, the solution of which will increase the efficiency of treatment facilities and optimize the process of applying flocculants. The ability to determine the moisture content of dehydrated residues using a meter operating on the IR reflectance principle was confirmed experimentally. The most suitable interference filters were selected based on an analysis of the obtained diffuse reflectance spectrum of the dehydrated residue in the range 1.0-2.7 μm. Calibration curves were constructed and compared for each filter set. A measuring filter with a transmittance maximum at 1.19 μm and a reference filter with a maximum at 1.3 μm gave the best agreement with the laboratory measurements.

  9. Micro-gen metering solutions

    Energy Technology Data Exchange (ETDEWEB)

    Elland, J.; Dickson, J.; Cranfield, P.

    2003-07-01

    This report summarises the results of a project to investigate the regulation of domestic electricity metering work and identify the most economic options for micro-generator installers to undertake work on electricity meters. A micro-generation unit is defined as an energy conversion system converting non-electrical energy into electrical energy and can include technologies such as photovoltaic systems, small-scale wind turbines, micro-hydroelectric systems, and combined heat and power systems. Details of six tasks are given and cover examination of the existing framework and legal documentation for metering work, the existing technical requirements for meter operators, meter operator personnel accreditation, appraisal of options for meter changes and for micro-generation installation, document change procedures, industry consultation, and a review of the costs implications of the options.

  10. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  11. Lodgepole pine site index in relation to synoptic measures of climate, soil moisture and soil nutrients.

    Science.gov (United States)

    G. Geoff Wang; Shongming Huang; Robert A. Monserud; Ryan J. Klos

    2004-01-01

    Lodgepole pine site index was examined in relation to synoptic measures of topography, soil moisture, and soil nutrients in Alberta. Data came from 214 lodgepole pine-dominated stands sampled as a part of the provincial permanent sample plot program. Spatial location (elevation, latitude, and longitude) and natural subregions (NSRs) were topographic variables that...

  12. Analysing Smart Metering Systems from a Consumer Perspective

    Science.gov (United States)

    Yesudas, Rani

    Many countries are deploying smart meters and Advanced Metering Infrastructure systems as part of demand management and grid modernisation efforts. Several of these projects are facing consumer resistance. The advertised benefits to the consumer appear mainly monetary but detailed analysis shows that financial benefits are hard to realise since the fixed services charges are high. Additionally, the data collected from smart meters have security and privacy implications for the consumer. These projects failed to consider end-users as an important stakeholder group during planning stages resulting in the design and roll-out of expensive systems, which do not demonstrate clear consumer benefits. The overall goal of the research reported in this thesis was to improve the smart metering system to deliver consumer benefits that increase confidence and acceptance of these projects. The smart metering system was examined from an end-user perspective for realistic insights into consumer concerns. Processes from Design Science Research methodology were utilised to conduct this research due to the utilitarian nature of the objective. Consumer segmentation was central to the proposed measures. Initially, a consumer-friendly risk analysis framework was devised, and appropriate requirement elicitation techniques were identified. Control options for smart meter data transfer and storage were explored. Various scenarios were analysed to determine consumer-friendly features in the smart metering system, including control options for smart meter data transfer and storage. Proposed functionalities (billing choices, feedback information and specific configurations to match the needs of different user segments) were studied using the Australian smart metering system. Smart meters vary in capabilities depending on the manufacturer, mode and place of deployment. The research showed that features proposed in this thesis are implementable in smart meters, by examining their applicability

  13. Using lamb waves tomonitor moisture absorption thermally fatigues composite laminates

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Sun; Cho, Youn Ho [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-06-15

    Nondestructive evaluation for material health monitoring is important in aerospace industries. Composite laminates are exposed to heat cyclic loading and humid environment depending on flight conditions. Cyclic heat loading and moisture absorption may lead to material degradation such as matrix breaking, debonding, and delamination. In this paper, the moisture absorption ratio was investigated by measuring the Lamb wave velocity. The composite laminates were manufactured and subjected to different thermal aging cycles and moisture absorption. For various conditions of these cycles, not only changes in weight and also ultrasonic wave velocity were measured, and the Lamb wave velocity at various levels of moisture on a carbon-epoxy plate was investigated. Results from the experiment show a linear correlation between moisture absorption ratio and Lamb wave velocity at different thermal fatigue stages. The presented method can be applied as an alternative solution in the online monitoring of composite laminate moisture levels in commercial flights.

  14. Smart meter adoption and deployment strategy for residential buildings in Indonesia

    International Nuclear Information System (INIS)

    Chou, Jui-Sheng; Gusti Ayu Novi Yutami, I

    2014-01-01

    Highlights: • Limited consumer awareness of smart meters contributes to skepticism. • Data obtained from a survey of energy users are analyzed using SEM. • A CAP index is developed via SEM results to measure consumer propensity for adopting smart meters. • The findings of this study enhance understanding of consumer perceptions and behaviors. • Concrete strategies are proposed to help policy makers and utility companies. - Abstract: For countries pursuing sustainable development and energy efficiency, the use of smart meters is considered a first step in allowing residential consumers to remotely control their energy consumption, and a promising technology for conserving limited energy resources. However, despite the growing interest in smart meters, limited consumer awareness, knowledge, and understanding of these devices contributes to skepticism. This study thus developed an index to measure consumer propensity to adopt smart meters in residential buildings. Data obtained from a survey of energy use by Indonesian households were analyzed using structural equation modeling to determine the interacting factors in consumer acceptance of smart meters. Consumer perceptions, expectations, and intentions regarding the potential use of smart meters in Indonesia were also discussed. The findings of this study enhance understanding of consumer perceptions and behaviors, and can help decision makers and energy utility companies develop policies and strategies for a “one-size-fits-all” program related to smart meter applications in future residential buildings

  15. Mathematical modeling of a survey-meter used to measure radioactivity in human thyroids: Monte Carlo calculations of the device response and uncertainties

    Science.gov (United States)

    Khrutchinsky, Arkady; Drozdovitch, Vladimir; Kutsen, Semion; Minenko, Victor; Khrouch, Valeri; Luckyanov, Nickolas; Voillequé, Paul; Bouville, André

    2012-01-01

    This paper presents results of Monte Carlo modeling of the SRP-68-01 survey meter used to measure exposure rates near the thyroid glands of persons exposed to radioactivity following the Chernobyl accident. This device was not designed to measure radioactivity in humans. To estimate the uncertainty associated with the measurement results, a mathematical model of the SRP-68-01 survey meter was developed and verified. A Monte Carlo method of numerical simulation of radiation transport has been used to calculate the calibration factor for the device and evaluate its uncertainty. The SRP-68-01 survey meter scale coefficient, an important characteristic of the device, was also estimated in this study. The calibration factors of the survey meter were calculated for 131I, 132I, 133I, and 135I content in the thyroid gland for six age groups of population: newborns; children aged 1 yr, 5 yr, 10 yr, 15 yr; and adults. A realistic scenario of direct thyroid measurements with an “extended” neck was used to calculate the calibration factors for newborns and one-year-olds. Uncertainties in the device calibration factors due to variability of the device scale coefficient, variability in thyroid mass and statistical uncertainty of Monte Carlo method were evaluated. Relative uncertainties in the calibration factor estimates were found to be from 0.06 for children aged 1 yr to 0.1 for 10-yr and 15-yr children. The positioning errors of the detector during measurements deviate mainly in one direction from the estimated calibration factors. Deviations of the device position from the proper geometry of measurements were found to lead to overestimation of the calibration factor by up to 24 percent for adults and up to 60 percent for 1-yr children. The results of this study improve the estimates of 131I thyroidal content and, consequently, thyroid dose estimates that are derived from direct thyroid measurements performed in Belarus shortly after the Chernobyl accident. PMID:22245289

  16. Implementation plan for smart meters in Ontario

    International Nuclear Information System (INIS)

    2004-01-01

    This paper presents Ontario Energy Board's implementation plan to install 800,000 smart meters by December 31, 2007. The objective is to help consumers control their electricity bills through conservation and demand response. The three conditions that will change power consumption habits are price changes in response to demand and supply forces; the ability of consumers to see and respond to the price signals; and, a measurement of the response so that consumers get credit for their actions. This paper identifies the mandatory technical requirements for smart meters and the support operations of distributors. It sets priorities, identifies barriers and regulatory mechanisms for cost recovery. It also discusses options for ownership of the meters. 18 refs., 1 tab., 2 figs

  17. High-Resolution Gas Metering and Nonintrusive Appliance Load Monitoring System

    Science.gov (United States)

    Tewolde, Mahder

    This thesis deals with design and implementation of a high-resolution metering system for residential natural gas meters. Detailed experimental measurements are performed on the meter to characterize and understand its measurement properties. Results from these experiments are used to develop a simple, fast and accurate technique to non-intrusively monitor the gas consumption of individual appliances in homes by resolving small amounts of gas usage. The technique is applied on an existing meter retrofitted with a module that includes a high-resolution encoder to collect gas flow data and a microprocessor to analyze and identify appliance load profiles. This approach provides a number of appealing features including low cost, easy installation and integration with automated meter reading (AMR) systems. The application of this method to residential gas meters currently deployed is also given. This is done by performing a load simulation on realistic gas loads with the aim of identifying the necessary parameters that minimize the cost and complexity of the mechanical encoder module. The primary benefits of the system are efficiency analysis, appliance health monitoring and real-time customer feedback of gas usage. Additional benefits of include the ability to detect very small leaks and theft. This system has the potential for wide scale market adoption.

  18. Real-time measurements of temperature, pressure and moisture profiles in High-Performance Concrete exposed to high temperatures during neutron radiography imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toropovs, N., E-mail: nikolajs.toropovs@rtu.lv [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Riga Technical University, Institute of Materials and Structures, Riga (Latvia); Lo Monte, F. [Politecnico di Milano, Department of Civil and Environmental Engineering, Milan (Italy); Wyrzykowski, M. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Lodz University of Technology, Department of Building Physics and Building Materials, Lodz (Poland); Weber, B. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); Sahmenko, G. [Riga Technical University, Institute of Materials and Structures, Riga (Latvia); Vontobel, P. [Paul Scherrer Institute, Laboratory for Neutron Scattering and Imaging, Villigen (Switzerland); Felicetti, R. [Politecnico di Milano, Department of Civil and Environmental Engineering, Milan (Italy); Lura, P. [Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf (Switzerland); ETH Zürich, Institute for Building Materials (IfB), Zürich (Switzerland)

    2015-02-15

    High-Performance Concrete (HPC) is particularly prone to explosive spalling when exposed to high temperature. Although the exact causes that lead to spalling are still being debated, moisture transport during heating plays an important role in all proposed mechanisms. In this study, slabs made of high-performance, low water-to-binder ratio mortars with addition of superabsorbent polymers (SAP) and polypropylene fibers (PP) were heated from one side on a temperature-controlled plate up to 550 °C. A combination of measurements was performed simultaneously on the same sample: moisture profiles via neutron radiography, temperature profiles with embedded thermocouples and pore pressure evolution with embedded pressure sensors. Spalling occurred in the sample with SAP, where sharp profiles of moisture and temperature were observed. No spalling occurred when PP-fibers were introduced in addition to SAP. The experimental procedure described here is essential for developing and verifying numerical models and studying measures against fire spalling risk in HPC.

  19. Moisture conditions in buildings

    DEFF Research Database (Denmark)

    Rode, Carsten

    2012-01-01

    Growth of mould requires the presence of moisture at a certain high level. In a heated indoor environment such moisture levels occur only if there is a reason for the moisture supply. Such moisture can come from the use of the building, because of malfunctioning constructions, or it can be the re......Growth of mould requires the presence of moisture at a certain high level. In a heated indoor environment such moisture levels occur only if there is a reason for the moisture supply. Such moisture can come from the use of the building, because of malfunctioning constructions, or it can...

  20. Evaluation of uncertainties in the calibration of radiation survey meter

    International Nuclear Information System (INIS)

    Potiens, M.P.A.; Santos, G.P.

    2006-01-01

    In order to meet the requirements of ISO 17025, the quantification of the expanded uncertainties of experimental data in the calibration of survey meters must be carried out using well defined concepts, like those expressed in the 'ISO-Guide to the Expression of Uncertainty in Measurement'. The calibration procedure of gamma ray survey meters involves two values that have to get their uncertainties clearly known: measurements of the instrument under calibration and the conventional true values of a quantity. Considering the continuous improvement of the calibration methods and set-ups, it is necessary to evaluate periodically the involved uncertainties in the procedures. In this work it is shown how the measurement uncertainties of an individual calibration can be estimated and how it can be generalized to be valid for others radiation survey meters. (authors)

  1. Examples of electromagnetic field (50-100 kHz) emissions from smart meters in Finland

    International Nuclear Information System (INIS)

    Paeaekkoenen, R.; Lundstroem, M.; Mustaparta, J.; Korpinen, L.

    2015-01-01

    The aim of this study was to collect example measurements of electromagnetic field exposure via smart meters for cable-transmitted (50-100 kHz) signal emissions in a meter room in Finland. We measured different smart meters and different concentrators. The magnetic fields in various situations on the meter surface ranged from 0.1-2.2 μT. The measured values were less than 10% of the ICNIRP reference level (RL) for the public (27 μT for those frequencies). When the typical spectator distance is considered, the ratio is even smaller: less than 1% of the RL. The electric fields (EFs) were between 0.2 and 2.5 V m -1 (RL 83 V m -1 for the public). In comparing the measured EF values with the RLs, the values are less than 3%. Based on our measurements, there is no need to improve the sheltering of the meters from the public. (authors)

  2. Revealing household characteristics from smart meter data

    International Nuclear Information System (INIS)

    Beckel, Christian; Sadamori, Leyna; Staake, Thorsten; Santini, Silvia

    2014-01-01

    Utilities are currently deploying smart electricity meters in millions of households worldwide to collect fine-grained electricity consumption data. We present an approach to automatically analyzing this data to enable personalized and scalable energy efficiency programs for private households. In particular, we develop and evaluate a system that uses supervised machine learning techniques to automatically estimate specific “characteristics” of a household from its electricity consumption. The characteristics are related to a household's socio-economic status, its dwelling, or its appliance stock. We evaluate our approach by analyzing smart meter data collected from 4232 households in Ireland at a 30-min granularity over a period of 1.5 years. Our analysis shows that revealing characteristics from smart meter data is feasible, as our method achieves an accuracy of more than 70% over all households for many of the characteristics and even exceeds 80% for some of the characteristics. The findings are applicable to all smart metering systems without making changes to the measurement infrastructure. The inferred knowledge paves the way for targeted energy efficiency programs and other services that benefit from improved customer insights. On the basis of these promising results, the paper discusses the potential for utilities as well as policy and privacy implications. - Highlights: • Many household characteristics can be automatically inferred from smart meter data. • We develop a system to infer employment status and number of occupants, for instance. • We evaluate our system analyzing data collected from 4232 households in Ireland. • The insights enable personalized and scalable efficiency campaigns for utilities. • Energy efficiency measures must be complemented by privacy protection

  3. The neutron probe and the detection of soil moisture

    International Nuclear Information System (INIS)

    Luft, G.; Morgenschweis, G.

    1981-01-01

    The authors present a brief outline of the direct and indirect field methods used at present in soil moisture measurement; particularly the advantages and disadvantages of neutron diffusion measurement are illustrated by means of various types of instruments available. The recently developed Wellingford Neutron Moisture Probe IH II, used for hydrological and pedohydrological fieldwork respectively, is presented and the first test results concerning the handling, measuring time, measured volume and layer thickness are discussed. (orig.) [de

  4. In-Situ Measurement of Soil Permittivity at Various Depths for the Calibration and Validation of Low-Frequency SAR Soil Moisture Models by Using GPR

    Directory of Open Access Journals (Sweden)

    Christian N. Koyama

    2017-06-01

    Full Text Available At radar frequencies below 2 GHz, the mismatch between the 5 to 15 cm sensing depth of classical time domain reflectometry (TDR probe soil moisture measurements and the radar penetration depth can easily lead to unreliable in situ data. Accurate quantitative measurements of soil water contents at various depths by classical methods are cumbersome and usually highly invasive. We propose an improved method for the estimation of vertical soil moisture profiles from multi-offset ground penetrating radar (GPR data. A semi-automated data acquisition technique allows for very fast and robust measurements in the field. Advanced common mid-point (CMP processing is applied to obtain quantitative estimates of the permittivity and depth of the reflecting soil layers. The method is validated against TDR measurements using data acquired in different environments. Depth and soil moisture contents of the reflecting layers were estimated with root mean square errors (RMSE on the order of 5 cm and 1.9 Vol.-%, respectively. Application of the proposed technique for the validation of synthetic aperture radar (SAR soil moisture estimates is demonstrated based on a case study using airborne L-band data and ground-based P-band data. For the L-band case we found good agreement between the near-surface GPR estimates and extended integral equation model (I2EM based SAR retrievals, comparable to those obtained by TDR. At the P-band, the GPR based method significantly outperformed the TDR method when using soil moisture estimates at depths below 30 cm.

  5. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P. [VTT Energy, Espoo (Finland); Vehvilaeinen, S. [Mittrix Oy (Finland); Rantanen, J. [Helsinki Energy Board, Helsinki (Finland)

    1996-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  6. Additional functions of remotely read kWh-meters

    Energy Technology Data Exchange (ETDEWEB)

    Koponen, P [VTT Energy, Espoo (Finland); Vehvilaeinen, S [Mittrix Oy (Finland); Rantanen, J [Helsinki Energy Board, Helsinki (Finland)

    1997-12-31

    In this presentation the possibilities to include new applications into remotely read smart kWh-meters are considered. New electronic meters can measure various electric quantities and have some extra calculating capacity. So they can be used to provide functions that distribution automation and the customer need and thus share the costs. Some applications like monitoring the state of the distribution network or locating faults are only for the utility, but many applications also need an interface to the customer or his automation system. Among those are monitoring the quality of electricity, estimating load curves, applying dynamic tariffs and selling electricity and accounting. As a special item, the continuous monitoring of the quality of electricity is discussed. This includes voltage levels, total distortion, asymmetry and so on. If such a kWh-meter indicates quality problems the situation can be detected with a suitable portable quality meter. The poor quality can be detected before it causes harm to equipment owned by the customers or the power distribution company. This presentation also presents a prototype of such a quality monitoring kWh-meter

  7. Real-Time Wireless Moisture Sensing in Concrete Using Interdigitated Stick-on Sensors

    Directory of Open Access Journals (Sweden)

    Rashed H. Bhuiyan

    2015-12-01

    Full Text Available The analyses, design, and performance of an interdigitated moisture sensor are presented. The analytical results clearly delineate the scope of the design in terms of the expected electric field penetration depth and interelectrode capacitance when the sensor is placed on top of a Material Under Test (MUT for a simple two electrode sensor. A multielectrode circular sensor was fabricated, instrumented, and used to measure concrete moisture content. Real-time moisture measurement results in both fresh concrete (when curing and dry concrete (when moisture intrusion is occurring are presented in a wireless system level measurement scenario where the measured results are relayed to a distant receiver using a wireless transmitter.

  8. Evaluation of SMOS soil moisture products over the CanEx-SM10 area

    Science.gov (United States)

    The Soil Moisture and Ocean Salinity (SMOS) Earth observation satellite was launched in November 2009 to provide global soil moisture and ocean salinity measurements based on L-Band passive microwave measurements. Since its launch, different versions of SMOS soil moisture products processors have be...

  9. Conducted interference on smart meters

    NARCIS (Netherlands)

    Keyer, Cornelis H.A.; Leferink, Frank

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. These meters are called smart meters when equipped with a communication link, and are replacing the conventional electromechanical meters. It is known that

  10. Moisture dependence of positron lifetime in Kevlar-49

    Science.gov (United States)

    Singh, Jag J.; Holt, William H.; Mock, Willis, Jr.

    1984-01-01

    Because of filamentary character of Kevlar-49 aramid fibers, there is some concern about the moisture uptake and its effect on plastic composites reinforced with Kevlar-49 fibers. As part of continuing studies of positron lifetime in polymers, we have measured positron lifetime spectra in Kevlar-49 fibers as a function of their moisture content. The long lifetime component intensities are rather low, being only of the order of 2-3 percent. The measured values of long component lifetimes at various moisture levels in the specimens are as follows: 2072 +/- 173 ps (dry); 2013 +/- 193 ps (20.7 percent saturation); 1665 +/- 85 ps (25.7 percent saturation); 1745 +/- 257 ps (32.1 percent saturation); and 1772 +/- 217 ps (100 percent saturation). It is apparent that the long component lifetime at first decreases and then increases as the specimen moisture content increases. These results have been compared with those inferred from Epon-815 and Epon-815/K-49 composite data.

  11. The soil moisture regimes beneath forest and an agricultural crop in southern India--Measurement and modelling

    International Nuclear Information System (INIS)

    Harding, R.J.; Hall, R.L.; Swaminath, M.H.; Murthy, K.V.

    1992-01-01

    The environmental effects of plantations of fast growing tree species has been a subject of some controversy in recent years. Extensive soil moisture measurements were made at three sites in Karnataka, southern India. At each site measurements were made beneath a number of vegetation types. These included fast growing tree species (Eucalyptus, Casuarina and Leucaena), degraded natural forest and an agricultural crop (ragi). The measurements indicate that beneath mature forest the available soil water is exhausted towards the end of the dry season, usually by March. The soil only becomes completely wetted if the subsequent monsoon has above average rainfall; during the weak monsoon of 1989 the soil remained approximately 150 mm below field capacity. After the monsoon (and during breaks in the monsoon) soil moisture depletion is between three and five mm per day. This rate decreases as the soil drys out. All the mature forest types show a similar soil water regime. This contrasts strongly with that of the agricultural crop, which shows much smaller changes. A range of soil water accounting models was applied to these data. The most successful are those which use the Penman formulation to estimate the potential evaporation and include a two-layer soil water depletion model. The more general Penman-Monteith formulation was also tested

  12. Development and application of groundwater flow meter in fractured rocks: Measurement of velocity and direction of groundwater flow in single well

    International Nuclear Information System (INIS)

    Kawanishi, M.; Miyakawa, K.; Hirata, Y.

    2001-01-01

    For the confirmation of safety for the geological disposal of radioactive wastes, it is very important to demonstrate the groundwater flow by in-situ investigation in the deep underground. We have developed a groundwater flow meter to measure simultaneously the velocity and direction of groundwater flow by means of detecting the electric potential difference between the groundwater to evaluate and the distilled water as a tracer in a single well. In this paper, we describe the outline of the groundwater flow meter system developed by CRIEPI and Taisei-Kiso-Sekkei Co. Ltd. and the evaluation methodology for observed data by using it in fractured rocks. Furthermore, applied results to in-situ tests at the Tounou mine of Japan Nuclear Fuel Cycle Development Institute (JNC) and the Aespoe Hard Rock Laboratory (HRL) of Swedish Nuclear Fuel and Waste Management Co. (SK) are described. Both sites are different type of fractured rock formations of granite. From these results, it was made clear that this flow meter system can be practically used to measure the groundwater flow direction and velocity as low as order of 1x10 -3 ∼10 -7 cm/sec. (author)

  13. One-dimensional scanning of moisture in heated porous building materials with NMR.

    Science.gov (United States)

    van der Heijden, G H A; Huinink, H P; Pel, L; Kopinga, K

    2011-02-01

    In this paper we present a new dedicated NMR setup which is capable of measuring one-dimensional moisture profiles in heated porous materials. The setup, which is placed in the bore of a 1.5 T whole-body scanner, is capable of reaching temperatures up to 500 °C. Moisture and temperature profiles can be measured quasi simultaneously with a typical time resolution of 2-5 min. A methodology is introduced for correcting temperature effects on NMR measurements at these elevated temperatures. The corrections are based on the Curie law for paramagnetism and the observed temperature dependence of the relaxation mechanisms occurring in porous materials. Both these corrections are used to obtain a moisture content profile from the raw NMR signal profile. To illustrate the methodology, a one-sided heating experiment of concrete with a moisture content in equilibrium with 97% RH is presented. This kind of heating experiment is of particular interest in the research on fire spalling of concrete, since it directly reveals the moisture and heat transport occurring inside the concrete. The obtained moisture profiles reveal a moisture peak building up behind the boiling front, resulting in a saturated layer. To our knowledge the direct proof of the formation of a moisture peak and subsequent moisture clogging has not been reported before. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Measurements of soil respiration and simple models dependent on moisture and temperature for an Amazonian southwest tropical forest

    NARCIS (Netherlands)

    Zanchi, F.B.; Rocha, Da H.R.; Freitas, De H.C.; Kruijt, B.; Waterloo, M.J.; Manzi, A.O.

    2009-01-01

    Soil respiration plays a significant role in the carbon cycle of Amazonian tropical forests, although in situ measurements have only been poorly reported and the dependence of soil moisture and soil temperature also weakly understood. This work investigates the temporal variability of soil

  15. Radiofrequency fields associated with the Itron smart meter

    International Nuclear Information System (INIS)

    Tell, R. A.; Sias, G. G.; Vazquez, A.; Sahl, J.; Turman, J. P.; Kavet, R. I.; Mezei, G.

    2008-01-01

    This study examined radiofrequency (RF) emissions from smart electric power meters deployed in two service territories in California for the purpose of evaluating potential human exposure. These meters included transmitters operating in a local area mesh network (RF LAN, ∼250 mW); a cell relay, which uses a wireless wide area network (WWAN, ∼1 W); and a transmitter serving a home area network (HAN, ∼70 mW). In all instances, RF fields were found to comply by a wide margin with the RF exposure limits established by the US Federal Communications Commission. The study included specialised measurement techniques and reported the spatial distribution of the fields near the meters and their duty cycles (typically <1 %) whose value is crucial to assessing time-averaged exposure levels. This study is the first to characterise smart meters as deployed. However, the results are restricted to a single manufacturer's emitters. (authors)

  16. Moisture buffer capacity of different insulation materials

    DEFF Research Database (Denmark)

    Peuhkuri, Ruut Hannele; Rode, Carsten; Hansen, Kurt Kielsgaard

    2004-01-01

    . In the isothermal tests the material samples were exposed to the same change in the relative humidity of the ambient air on both sides, while the samples were exposed to variations in relative humidity only on the cold side in the non-isothermal tests. The results of these rather different measurement principles...... lead to more durable constructions. In this paper, a large range of very different thermal insulation materials have been tested in specially constructed laboratory facilities to determine their moisture buffer capacity. Both isothermal and nonisothermal experimental set-ups have been used...... are discussed, and different ways are presented how to determine the moisture buffer capacity of the materials using partly standard material parameters and partly parameters determined from the actual measurements. The results so far show that the determination of moisture buffer capacity is very sensitive...

  17. Understanding natural moisturizing mechanisms: implications for moisturizer technology.

    Science.gov (United States)

    Chandar, Prem; Nole, Greg; Johnson, Anthony W

    2009-07-01

    Dry skin and moisturization are important topics because they impact the lives of many individuals. For most individuals, dry skin is not a notable concern and can be adequately managed with current moisturizing products. However, dry skin can affect the quality of life of some individuals because of the challenges of either harsh environmental conditions or impaired stratum corneum (SC) dry skin protection processes resulting from various common skin diseases. Dry skin protection processes of the SC, such as the development of natural moisturizing factor (NMF), are complex, carefully balanced, and easily perturbed. We discuss the importance of the filaggrin-NMF system and the composition of NMF in both healthy and dry skin, and also reveal new insights that suggest the properties required for a new generation of moisturizing technologies.

  18. Performance of a Tilt Current Meter in the Surf Zone

    DEFF Research Database (Denmark)

    Hansen, Asger Bendix; Carstensen, Stefan; Christensen, Drude Fritzbøger

    2017-01-01

    Tilt Current Meters (TCM’s) are relatively simple and inexpensive instruments for measuring currents in rivers and inthe sea. Their low cost and easy deployment means that a relatively large number of TCM’s can be deployed comparedto more conventional current meters such as Acoustic Doppler...

  19. Correlation between macro texture measures carried out by the volumetric method and by different laser texture meter

    International Nuclear Information System (INIS)

    Parra Ruiz, L.; Yanguas Gonzalez, S. J.

    2013-01-01

    The reference value for the measurement of surface macro texture in the Spanish Main Road Network is the MTD or Mean Texture Depth (PMT, Profundidad Media de Textura), obtained by means of the volumetric methods, in accordance with the standard UNE EN 13036-1:12010. The fact that it is a spot measurement that requires road closures makes it an expensive procedure as well as slow and dangerous. In addition to this, the test results are relatively sensitive to the operator, being the procedure not too suitable for systematic surveys. These are some of the reasons that have contributed to the development of texture meter laser devices that can be assembled on board of vehicles, circulating without interfering with the normal traffic flow and providing a parameter named the MPD (Mean Depth Profile). According to the standard UNE-EN ISO 13473-1:2006, it is possible to estimate the texture obtained by volumetric methods, with the parameter ETD (Estimated Texture Depth) through the equation: ETD=0,8 x MPD+0.2 In 2008 CEDEX conducted a study that correlated macro texture measures obtained by means of the volumetric method with such carried out by different laser texture meters. The equations yield a better relation between MPD and MTD were dependent on the measurement device used and were not linear equations type, as is it indicated in the standard, but exponential type equations. (Author) 6 refs.

  20. Density meter algorithm and system for estimating sampling/mixing uncertainty

    International Nuclear Information System (INIS)

    Shine, E.P.

    1986-01-01

    The Laboratories Department at the Savannah River Plant (SRP) has installed a six-place density meter with an automatic sampling device. This paper describes the statistical software developed to analyze the density of uranyl nitrate solutions using this automated system. The purpose of this software is twofold: to estimate the sampling/mixing and measurement uncertainties in the process and to provide a measurement control program for the density meter. Non-uniformities in density are analyzed both analytically and graphically. The mean density and its limit of error are estimated. Quality control standards are analyzed concurrently with process samples and used to control the density meter measurement error. The analyses are corrected for concentration due to evaporation of samples waiting to be analyzed. The results of this program have been successful in identifying sampling/mixing problems and controlling the quality of analyses

  1. Density meter algorithm and system for estimating sampling/mixing uncertainty

    International Nuclear Information System (INIS)

    Shine, E.P.

    1986-01-01

    The Laboratories Department at the Savannah River Plant (SRP) has installed a six-place density meter with an automatic sampling device. This paper describes the statisical software developed to analyze the density of uranyl nitrate solutions using this automated system. The purpose of this software is twofold: to estimate the sampling/mixing and measurement uncertainties in the process and to provide a measurement control program for the density meter. Non-uniformities in density are analyzed both analytically and graphically. The mean density and its limit of error are estimated. Quality control standards are analyzed concurrently with process samples and used to control the density meter measurement error. The analyses are corrected for concentration due to evaporation of samples waiting to be analyzed. The results of this program have been successful in identifying sampling/mixing problems and controlling the quality of analyses

  2. Thermogravimetric analysis for rapid assessment of moisture diffusivity in polydisperse powder and thin film matrices.

    Science.gov (United States)

    Thirunathan, Praveena; Arnz, Patrik; Husny, Joeska; Gianfrancesco, Alessandro; Perdana, Jimmy

    2018-03-01

    Accurate description of moisture diffusivity is key to precisely understand and predict moisture transfer behaviour in a matrix. Unfortunately, measuring moisture diffusivity is not trivial, especially at low moisture values and/or elevated temperatures. This paper presents a novel experimental procedure to accurately measure moisture diffusivity based on thermogravimetric approach. The procedure is capable to measure diffusivity even at elevated temperatures (>70°C) and low moisture values (>1%). Diffusivity was extracted from experimental data based on "regular regime approach". The approach was tailored to determine diffusivity from thin film and from poly-dispersed powdered samples. Subsequently, measured diffusivity was validated by comparing to available literature data, showing good agreement. Ability of this approach to accurately measure diffusivity at a wider range of temperatures provides better insight on temperature dependency of diffusivity. Thus, this approach can be crucial to ensure good accuracy of moisture transfer description/prediction especially when involving elevated temperatures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Evaluation of Assimilated SMOS Soil Moisture Data for US Cropland Soil Moisture Monitoring

    Science.gov (United States)

    Yang, Zhengwei; Sherstha, Ranjay; Crow, Wade; Bolten, John; Mladenova, Iva; Yu, Genong; Di, Liping

    2016-01-01

    Remotely sensed soil moisture data can provide timely, objective and quantitative crop soil moisture information with broad geospatial coverage and sufficiently high resolution observations collected throughout the growing season. This paper evaluates the feasibility of using the assimilated ESA Soil Moisture Ocean Salinity (SMOS)Mission L-band passive microwave data for operational US cropland soil surface moisture monitoring. The assimilated SMOS soil moisture data are first categorized to match with the United States Department of Agriculture (USDA)National Agricultural Statistics Service (NASS) survey based weekly soil moisture observation data, which are ordinal. The categorized assimilated SMOS soil moisture data are compared with NASSs survey-based weekly soil moisture data for consistency and robustness using visual assessment and rank correlation. Preliminary results indicate that the assimilated SMOS soil moisture data highly co-vary with NASS field observations across a large geographic area. Therefore, SMOS data have great potential for US operational cropland soil moisture monitoring.

  4. Determination of Soil Moisture Content using Laboratory Experimental and Field Electrical Resistivity Values

    Science.gov (United States)

    Hazreek, Z. A. M.; Rosli, S.; Fauziah, A.; Wijeyesekera, D. C.; Ashraf, M. I. M.; Faizal, T. B. M.; Kamarudin, A. F.; Rais, Y.; Dan, M. F. Md; Azhar, A. T. S.; Hafiz, Z. M.

    2018-04-01

    The efficiency of civil engineering structure require comprehensive geotechnical data obtained from site investigation. In the past, conventional site investigation was heavily related to drilling techniques thus suffer from several limitations such as time consuming, expensive and limited data collection. Consequently, this study presents determination of soil moisture content using laboratory experimental and field electrical resistivity values (ERV). Field and laboratory electrical resistivity (ER) test were performed using ABEM SAS4000 and Nilsson400 soil resistance meter. Soil sample used for resistivity test was tested for characterization test specifically on particle size distribution and moisture content test according to BS1377 (1990). Field ER data was processed using RES2DINV software while laboratory ER data was analyzed using SPSS and Excel software. Correlation of ERV and moisture content shows some medium relationship due to its r = 0.506. Moreover, coefficient of determination, R2 analyzed has demonstrate that the statistical correlation obtain was very good due to its R2 value of 0.9382. In order to determine soil moisture content based on statistical correlation (w = 110.68ρ-0.347), correction factor, C was established through laboratory and field ERV given as 19.27. Finally, this study has shown that soil basic geotechnical properties with particular reference to water content was applicably determined using integration of laboratory and field ERV data analysis thus able to compliment conventional approach due to its economic, fast and wider data coverage.

  5. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    Science.gov (United States)

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  6. Real Time Phase Noise Meter Based on a Digital Signal Processor

    Science.gov (United States)

    Angrisani, Leopoldo; D'Arco, Mauro; Greenhall, Charles A.; Schiano Lo Morille, Rosario

    2006-01-01

    A digital signal-processing meter for phase noise measurement on sinusoidal signals is dealt with. It enlists a special hardware architecture, made up of a core digital signal processor connected to a data acquisition board, and takes advantage of a quadrature demodulation-based measurement scheme, already proposed by the authors. Thanks to an efficient measurement process and an optimized implementation of its fundamental stages, the proposed meter succeeds in exploiting all hardware resources in such an effective way as to gain high performance and real-time operation. For input frequencies up to some hundreds of kilohertz, the meter is capable both of updating phase noise power spectrum while seamlessly capturing the analyzed signal into its memory, and granting as good frequency resolution as few units of hertz.

  7. Propagation of soil moisture memory into the climate system

    Science.gov (United States)

    Orth, R.; Seneviratne, S. I.

    2012-04-01

    Soil moisture is known for its integrative behaviour and resulting memory characteristics. Associated anomalies can persist for weeks or even months into the future, making initial soil moisture an important potential component in weather forecasting. This is particularly crucial given the role of soil moisture for land-atmosphere interactions and its impacts on the water and energy balances on continents. We present here an analysis of the characteristics of soil moisture memory and of its propagation into runoff and evapotranspiration in Europe, based on available measurements from several sites across the continent and expanding a previous analysis focused on soil moisture [1]. We identify the main drivers of soil moisture memory at the analysed sites, as well as their role for the propagation of soil moisture persistence into runoff and evapotranspiration memory characteristics. We focus on temporal and spatial variations in these relationships and identify seasonal and latitudinal differences in the persistence of soil moisture, evapotranspiration and runoff. Finally, we assess the role of these persistence characteristics for the development of agricultural and hydrological droughts. [1] Orth and Seneviratne: Analysis of soil moisture memory from observations in Europe; submitted to J. Geophysical Research.

  8. Data system for multiplexed water-current meters

    Science.gov (United States)

    Ramsey, C. R.

    1977-01-01

    Flow rates at 32 flood plain locations are measured simultaneously by single digital logic unit with high noise immunity. Water flowing through pygmy current meters rotates element that closes electrical contact once every resolution, so flow rate is measured by counting number of closures in time interval.

  9. An automated, noncontact laser profile meter for measuring soil roughness in situ

    International Nuclear Information System (INIS)

    Bertuzzi, P.; Caussignac, J.M.; Stengel, P.; Morel, G.; Lorendeau, J.Y.; Pelloux, G.

    1990-01-01

    This paper describes a new optical technique for measuring in situ soil surface roughness profiles using a laser profile meter. The described method uses a low-power HeNe (helium-neon) laser as a laser source and a matrix-array detector, as the laser image. The matrix-array detector gives a defect-of-focus laser image of the soil. Soil elevation is measured by projecting a laser beam normally onto the soil surface and measuring the ratio (Ir/It) on the matrix-array detector between the referenced intensity of the return Laser beam (Ir), measured by the central cell of the detector and the total intensity (It), measured by all the cells of the detector. The measured profile leads to 1001 sampled values (volt, range 0 to 10 V) of the surface height profile, at a constant increment of 0.002 m, registered automatically on a microcomputer. A calibration is made in the laboratory in order to convert the electrical measurements into elevation data. The method is universal and can be adapted to different scales of soil surface roughness. Changing the scale is done by changing the lens. Tests were carried out to improve this method for field use and to compare this technique with a method of reference. This technique is considerably quicker and causes no disturbance to the soil. The accuracy on height measurement depends on the choice of the lens. The small focal lens is convenient for smooth soil surfaces. The accuracy on height measurement is less than 0.75 mm. The wide focal lens is convenient for rough soil surfaces. The accuracy on height measurement is estimated at about 1.0 to 1.5 mm

  10. Effects of varying hydraulics on the calibration of eight path chordal ultrasonic meters

    International Nuclear Information System (INIS)

    Hauser, E.; Estrada, H.; Regan, J.

    2003-01-01

    Eight path transit time ultrasonic meters are being used in the US, Europe and Japan to support measurement uncertainty power uprates of nuclear power plants. Power uprates rely on the demonstration of improved power accuracy to justify a reduction in the traditional 2% margin between operating power and the power at which loss of coolant accidents and other transients have been analyzed. The flow, density and enthalpy of the feedwater are key elements in the power calculation, and the eight path ultrasonic meters measure the flow and temperature from which these elements are derived. A key element in the uncertainty analysis for these meters is an allowance for the uncertainties that the feedwater flow profiles introduce in the meters' flow calibrations. To minimize and bound this uncertainty calibration tests are performed on each eight path element to be used in an uprate application. This paper describes extensive testing of a prototype eight path meter, results of which have be used to define the sensitivity of 8 path meters to broad variations in flow profiles, both axial and transverse and to establish a methodology whereby the impact of these changes on the uncertainty of the meters can be minimized. This testing confirms the general insensitivity of 8 path chordal systems to axial and transverse fluid velocity profiles. An 8 path chordal system provides a quantitative measurement of the flatness of the axial profile, which allows a quantitative assessment of the differences in hydraulic profile seen by a meter in a plant versus the hydraulic profile seen by that same meter in the calibration lab. Since the sensitivity of the meter's calibration can be established as a function of profile flatness in the lab through parametric testing, the profile flatness in the plant can be used to confirm or to adapt as necessary the calibration coefficient measured in the lab for use in the plant. (author)

  11. FUSION OF VENTURI AND ULTRASONIC FLOW METER FOR ENHANCED FLOW METER CHARACTERISTICS USING FUZZY LOGIC

    Directory of Open Access Journals (Sweden)

    K.V. Santhosh

    2015-04-01

    Full Text Available This paper proposes a technique for measurement of liquid flow using venturi and ultrasonic flow meter(UFM to have following objectives a to design a multi-sensor data fusion (MSDF architecture for using both the sensors, b improve sensitivity and linearity of venturi and ultrasonic flow meter, and c detect and diagnosis of faults in sensor if any. Fuzzy logic algorithm is used to fuse outputs of both the sensor and train the fuzzy block to produces output which has an improved characteristics in terms of both sensitivity and linearity. For identification of sensor faults a comparative test algorithm is designed. Once trained proposed technique is tested in real life, results show successful implementation of proposed objectives.

  12. Performance of combination of a Venturi and nuclear fraction meter in SAGD production operations

    Energy Technology Data Exchange (ETDEWEB)

    Hompoth, D.; Khun, N. [Suncor Energy, Calgary, AB (Canada); Pinguet, B.G.; Guerra, E. [Schlumberger Canada Ltd., Edmonton, AB (Canada)

    2008-07-01

    This paper described a multiphase flow meter (MFM) that used a Venturi and nuclear fraction meter combination for steam assisted gravity drainage (SAGD) well production testing. The device was designed by re-engineering a flow model and fluid property package to measure the steam phases. The meter was designed to improve pump monitoring processes in SAGD operations. The technology combined 2 basic measurement steps. The first was a nuclear multi Gamma-ray fraction meters which measured the fraction of each constituent at the Venturi tube's throat at high frequencies. Fractions were then determined from the solution of 3 simultaneous equations related to the Gamma ray attenuation, and a fraction balance equation. Pressure and temperature measurements were used to predict the fluid properties at line conditions. Primary outputs were based on nuclear measurements, gas fractions, water liquid ratios, and mixture densities. Secondary outputs from the meter included volumetric flow rates. Stability, dynamic responses, and reproducibility rates of the MFM were also presented. 9 refs., 6 tabs., 17 figs.

  13. Feasibility Study of Power Uprate Using Ultrasonic Flow Meters in NPPs

    International Nuclear Information System (INIS)

    Kim, Tae Mi; Heo, Gyun Young

    2010-01-01

    Feedwater flowrate is an important input parameter in establishing the plant's operating power level. In Korean nuclear power plants, venturi flow meters have been used for measuring the feedwater flow of the secondary side. However, as time goes on, the fouling in venture meters could cause measurement uncertainties to grow and that could lead to operation at less than about 2% of the licensed thermal power limit. In order to resolve the problem, nuclear power plants in other countries use Ultrasonic Flow Meters (UFMs) which have relatively lower measurement uncertainty (about 0.5%) instead of venturi flow meters and have reduced the errors from the fouling in venturi-type flow meters. USA amended 10 CFR 50 Appendix K so that US nuclear power plants can use real value of Core Operating Limit Supervisory System (COLSS) uncertainty, which is currently fixed as 2%, by adopting the UFM. Korea also has been amended the law in order to get benefits from the technology. In this study, we are going to present the fundamental principles of UFMs and the advantages and disadvantages of its installation. Also, we inquire into the conventional uses of UFMs in the overseas sites and then check what is needed to consider for its domestic application

  14. On sizing of flow meters used in customer accounting devices in district heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Ingimundarson, Ari; Wollerstrand, J.; Arvastson, Lars

    1998-12-31

    The paper deals with accuracy problems when heat energy consumption in district heating (DH) systems is calculated by measuring the DH water flow rate and its cooling. An investigation on the influence that sizing of flow meters used has on the accuracy of DH water flow measurements in a typical DH subscriber station is presented. Furthermore the consequences of the choice of flow meter size on energy metering accuracy is studied. The goal is to determine rules leading to optimal sizing of the flow meters 9 refs, 14 figs

  15. Real-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry.

    Science.gov (United States)

    Wang, Guochao; Tan, Lilong; Yan, Shuhua

    2018-02-07

    We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direct synthetic wavelength interferometry is elaborately introduced by launching a fifth wavelength to extend a non-ambiguous range for meter-scale measurement. A linearity test performed comparatively with a He-Ne laser interferometer shows a residual error of less than 70.8 nm in peak-to-valley over a 3 m distance, and a 10 h distance comparison is demonstrated to gain fractional deviations of ~3 × 10 -8 versus 3 m distance. Test results reveal that the presented absolute interferometer enables precise, stable, and long-term distance measurements and facilitates absolute positioning applications such as large-scale manufacturing and space missions.

  16. Digital reactor period meter type of NSSG-7

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, S W

    1981-01-01

    The paper presents the idea and electronic circuits of the Digital Reactor Period Meter. The instrument consists of a neutron ionisation chamber, the amplifier logarithming the output chamber current, the circuit taking two samples of the log amplifier output signal and subtracting them, the analog -to -digital dividing circuit and the scaler providing the final information of the reactor period value in seconds and in the digital form. Besides it, the instrument produces the acoustic signal in the case, when the rise-time of neutron flux exceeds the permitted value. The untypical construction of the reactor period meter has been developed to obtain both good measurement accuracy and the resistance against the electromagnetic background pulses interfering with the measuring process. The applied measuring system has been patented.

  17. Influence of moisture content on radon diffusion in soil

    International Nuclear Information System (INIS)

    Singh, M.; Ramola, R.C.; Singh, S.; Virk, H.S.

    1990-01-01

    Radon diffusion from soil has been studied as a function of the moisture content of the soil. A few simple experiments showed that up to a certain moisture content the radon diffusion increased with increasing moisture. A sharp rise in radon concentration occurred as the moisture was increased from the completely dry state to 13% water by weight. The radon flux was measured for columns of dry, moist and water saturated soil. The highest flux came from the column filled with moist soil. Water saturated soil gave the lowest flux because of the much lower diffusion coefficient of radon through water. (author)

  18. Determination of moisture in bagasse by neutron reflection

    International Nuclear Information System (INIS)

    Diaz Rizo, O.; Suarez, J.C.

    1990-01-01

    For the first time in Cuba organic samples were analyzed by neutron reflection method. The feasibility of this method to determinate the moisture grade in sugar cane bagasse is fixed. From 0 to 50w% moisture grade with 2-3% relative accuracy can be determinated using 10m. measuring time. 7 refs

  19. Observer Based Fault Detection and Moisture Estimating in Coal Mill

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Mataji, Babak

    2008-01-01

    In this paper an observer-based method for detecting faults and estimating moisture content in the coal in coal mills is presented. Handling of faults and operation under special conditions, such as high moisture content in the coal, are of growing importance due to the increasing...... requirements to the general performance of power plants. Detection  of faults and moisture content estimation are consequently of high interest in the handling of the problems caused by faults and moisture content. The coal flow out of the mill is the obvious variable to monitor, when detecting non-intended drops in the coal...... flow out of the coal mill. However, this variable is not measurable. Another estimated variable is the moisture content, which is only "measurable" during steady-state operations of the coal mill. Instead, this paper suggests a method where these unknown variables are estimated based on a simple energy...

  20. 40 CFR 1065.220 - Fuel flow meter.

    Science.gov (United States)

    2010-07-01

    ... follows: (1) Use the actual value of calculated raw exhaust flow rate in the following cases: (i) For... ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.220 Fuel flow meter. (a) Application. You may use fuel flow in combination with a chemical balance of carbon (or oxygen...

  1. Optical system for a universal luminance meter

    NARCIS (Netherlands)

    Schreuder, D.A.

    1965-01-01

    There is a need for luminance meters in various fields of photometry having these characteristics: a- objective method of measurements. b. variable shape and size of measurement area. c- absence of parallax during aiming operations. d- Possibility of observing the part of the field of view to be

  2. On-line determination of moisture in coal and coke

    International Nuclear Information System (INIS)

    Cutmore, N.G.; Sowerby, B.D.

    1987-01-01

    The CSIRO Division of Mineral Engineering is developing various techniques for the on-line determination of moisture in coal and coke, and some instruments are now commercially available. These techniques permit accurate and rapid determination of moisture in materials directly on conveyor belts or in bins. The most promising techniques for direct on-belt measurement of moisture in coal are capacitance and microwave transmission. A non-contacting under-belt capacitance and gamma-ray backscatter technique has determined moisture in coal to better than 0.5 wt% in field tests. CSIRO is developing a fast neutron and gamma-ray transmission technique, which is proving very accurate in laboratory tests. This technique overcomes many of the limitations of thermal neutrons moisture gauges

  3. Apparent losses due to domestic water meter under-registration in South Africa

    OpenAIRE

    Couvelis, FA; van Zyl, JE

    2015-01-01

    This study investigated the extent of apparent losses due to water meter under-registration in South Africa. This was done by first estimating the under-registration of new meters due to on-site leakage, and then the additional under-registration due to meter aging. The extent and flow distributions of on-site leakage were determined through field studies in Cape Town, Mangaung and Johannesburg, by measuring the flow through new water meters when no legitimate consumption occurred on the prop...

  4. Automatic moisture content determination on biomass with NIR and radio frequency spectroscopy; Automatisk fukthaltsmaetning paa biobraenslen med NIR samt radiofrekvent spektroskopi

    Energy Technology Data Exchange (ETDEWEB)

    Dahlquist, Erik; Nystroem, Jenny; Thorin, Eva; Paz, Ana de la [Maelardalen Univ. (Sweden). Dept. of Public Technology; Axrup, Lars [Stora Enso AB (Sweden)

    2005-08-01

    The goal with the project has been to evaluate two methods for determination of moisture content in biomass fuels and to determine if these methods can be used in practice in connection with delivery control of biomass at power plants. Tests have been performed with different biomass qualities and with two different measurement methods within a large moisture span, 0.6-72%. The two methods have been NIR (Near Infrared spectroscopy), and RF (Radio Frequency spectroscopy). The NIR-method is a surface analysis method, where hydro-carbons like wood have a different absorption pattern than water. The RF-method is a bulk method and utilizes that wood and water have different dielectric constants. Radio waves thus are affected differently by transportation through wet and dry biomass. In this project we have studied how representative sampling can be achieved from a large volume of delivered biomass fuel. We also have performed calibration with mixtures of the different fuels. Sampling has been performed by extracting biomass in a four meter long screw from the large volume as it is poured into a storage vessel. A conveyor belt is then transporting the material to the measurement systems. Two different NIR-instruments, DA (Diod Array) -NIR respective FT (Fourier Transform)- NIR, were placed above the conveyor belt. The material was collected from the belt into the measuring vessel for the RF, a 200 liter 'oil barrel'. The radio waves were sent from the transceiver into the sample from above without direct contact between the biomass and the transceiver antenna. Six different fuels were studied separately. Calibration was performed where the moisture content was varied by mixing relatively dry fuel with humidified biomass in different proportions a day before the measurements. Samples were taken from each mixture in connection with the measurements, from the conveyor belt. The samples were made in such a way that they represented the whole volume as good as

  5. Development of an in-line grout meter for improved quality control

    International Nuclear Information System (INIS)

    Del Cul, G.D.; Gilliam, T.M.

    1991-05-01

    This report documents progress to date on the development of an in-line grout meter and demonstration of its applicability at operating temperature of 50 degree C. The grout meter, which is based on measurement of grout electrical resistance/capacitance, is intended to provide real-time measurements of grout mix ratio (ratio of dry-solids-blend materials to waste). 4 refs., 6 figs., 5 tabs

  6. A soil moisture and temperature network for SMOS validation in Western Denmark

    DEFF Research Database (Denmark)

    Bircher, Simone; Skou, Niels; Jensen, K. H.

    2011-01-01

    The Soil Moisture and Ocean Salinity Mission (SMOS) acquires surface soil moisture data globally, and thus product validation for a range of climate and environmental conditions across continents is a crucial step. For this purpose, a soil moisture and temperature network of Decagon ECH2O 5TE...... SMOS pixel (44 × 44 km), which is representative of the land surface conditions of the catchment and with minimal impact from open water (2) arrangement of three network clusters along the precipitation gradient, and (3) distribution of the stations according to respective fractions of classes...... representing the prevailing environmental conditions. Overall, measured moisture and temperature patterns could be related to the respective land cover and soil conditions. Texture-dependency of the 0–5 cm soil moisture measurements was demonstrated. Regional differences in 0–5 cm soil moisture, temperature...

  7. Moisture dependence of positron annihilation spectra in nylon-6

    International Nuclear Information System (INIS)

    Singh, J.J.; Clair, T.L.S.; Holt, W.H.; Mock, W. Jr.

    1984-01-01

    Positron annihilation time spectra have been measured in nylon-6 specimens as a function of their moisture content. The measured average longlife component lifetime values are: 1722 +- 47 ps (dry), 1676 +- 40 ps (14.6% saturation value), 1718 +- 26 ps (29.3% saturation value), 1720 +- 35 ps (50% of saturation value), 1857 +- 35 ps (78.1% of saturation value) and 1936 +- 57 ps (saturated). It is noted that the longlife component lifetime at first decreases and then increases with increasing moisture content in the specimens. This behavior is quite different from that observed in earlier studies of various epoxy, polyamide, and polyimide materials, where the longlife component lifetime decreased linearly with increasing moisture content. The longlife component intensity on the other hand, decreases steadily as the moisture content increases from 0 to 100% of the saturation value. A possible explanation for these anomalous features is discussed. (orig.)

  8. New technique of insitu soil moisture sampling for environmental isotope analysis applied at 'Pilat-dune' near Bordeaux

    International Nuclear Information System (INIS)

    Thoma, G.; Esser, N.; Sonntag, C.; Weiss, W.; Rudolph, J.; Leveque, P.

    1978-01-01

    A new soil-air suction method with soil water vapor adsorption by 4 A-molecular sieve provides soil moisture samples from various depths for environmental isotope analysis and yields soil temperature profiles. A field tritium tracer experiment shows that this insitu sampling method has an isotope profile resolution of about 5-10 cm only. Application of this method in the Pilat sand dune (Bordeaux/France) yielded deuterium and tritium profiles down to 25 meters depth. Bomb tritium measurements of monthly lysimeter percolate samples available since 1961 show that the tritium response has a mean delay of 5 months in case of a sand lysimeter and of 2.5 years for a loess loam lysimeter. A simple HETP model simulates the layered downward movement of soil water and the longitudinal dispersion in the lysimeters. Field capacity and evapotranspiration taken as open parameters yield tritium concentration values of the lysimeters' percolate which are in close agreement with the experimental results. Based on local meteorological data the HETP model applied to tritium tracer experiments in the unsaturated zone further yiels an individual prediction of the momentary tracer position and of the soil moisture distribution. This prediction can be checked experimentally at selected intervals by coring. (orig.) [de

  9. Evaluation of a portable urinary pH meter and reagent strips.

    Science.gov (United States)

    De Coninck, Vincent; Keller, Etienne Xavier; Rodríguez-Monsalve, María; Haymann, Jean-Philippe; Doizi, Steeve; Traxer, Olivier

    2018-04-27

    To evaluate a portable electronic pH meter and to put its accuracy in perspective with reagent strips read by a layperson, a healthcare professional and an electronic reading device. Based on a pre-analysis on 20 patients, a sample size of 77 urine aliquots from healthy volunteers was necessary to obtain sufficient study power. Measurements of urinary pH were obtained by use of reagent strips, a portable pH meter and a laboratory pH meter (gold standard). Reagents strips were read by a professional experienced in interpreting strips, a layperson, and an electronic strip reader. The mean matched pair difference between measurement methods was analyzed by the paired t-test. The degree of correlation and agreement were evaluated by the Pearson's correlation coefficient and Bland-Altman plots, respectively. The mean matched pair difference between the gold standard and all other pH measurement methods was the smallest with the portable electronic pH meter (bias 0.01, 95% CI -0.07 to 0.08; p=0.89), followed by strips read by a professional (bias -0.09, 95% CI -0.21 to 0.02; p=0.10), layperson (bias -0.17, 95% CI -0.31 to -0.04; p=0.015) and electronic strip reader (bias -0.29, 95% CI -0.41 to -0.16; pmeter achieved the highest Pearson's correlation coefficient and narrowest 95% limits of agreement, followed by strip interpretation by a professional, the electronic strip reader and the layperson. In order to quantify the ability of pH measurement methods to correctly classify values within a predefined urinary pH target range, we performed classification tests for several stones. The portable electronic pH meter outperformed all other measurement methods for negative predictive values. Findings of the current study support that the portable electronic pH meter is a reliable pH measuring device. It seems to be more accurate compared to reagent strips readings.

  10. DEVELOPMENT OF NEW HYPERSPECTRAL ANGLE INDEX FOR ESTIMATION OF SOIL MOISTURE USING IN SITU SPECTRAL MEASURMENTS

    Directory of Open Access Journals (Sweden)

    M. R. Mobasheri

    2013-10-01

    Full Text Available Near-surface soil moisture is one of the crucial variables in hydrological processes, which influences the exchange of water and energy fluxes at the land surface/atmosphere interface. Accurate estimate of the spatial and temporal variations of soil moisture is critical for numerous environmental studies. On the other hand, information of distributed soil moisture at large scale with reasonable spatial and temporal resolution is required for improving climatic and hydrologic modeling and prediction. The advent of hyperspectral imagery has allowed examination of continuous spectra not possible with isolated bands in multispectral imagery. In addition to high spectral resolution for individual band analyses, the contiguous narrow bands show characteristics of related absorption features, such as effects of strong absorptions on the band depths of adjacent absorptions. Our objective in this study was to develop a new spectral angle index to estimate soil moisture based on spectral region (350 and 2500 nm. In this paper, using spectral observations made by ASD Spectroradiometer for predicting soil moisture content, two soil indices were also investigated involving the Perpendicular Drought Index (PDI, NMDI (Normalized Multi-band Drought Index indices. Correlation and regression analysis showed a high relationship between PDI and the soil moisture percent (R2 = 0.9537 and NMDI (R2 = 0.9335. Furthermore, we also simulated these data according to the spectral range of some sensors such as MODIS, ASTER, ALI and ETM+. Indices relevant these sensors have high correlation with soil moisture data. Finally, we proposed a new angle index which shows significant relationship between new angle index and the soil moisture percentages (R2 = 0.9432.angle index relevant bands 3, 4, 5, 6, 7 MODIS also showing high accuracy in estimation of soil moisture (R2 = 0.719.

  11. Australian Soil Moisture Field Experiments in Support of Soil Moisture Satellite Observations

    Science.gov (United States)

    Kim, Edward; Walker, Jeff; Rudiger, Christopher; Panciera, Rocco

    2010-01-01

    Large-scale field campaigns provide the critical fink between our understanding retrieval algorithms developed at the point scale, and algorithms suitable for satellite applications at vastly larger pixel scales. Retrievals of land parameters must deal with the substantial sub-pixel heterogeneity that is present in most regions. This is particularly the case for soil moisture remote sensing, because of the long microwave wavelengths (L-band) that are optimal. Yet, airborne L-band imagers have generally been large, heavy, and required heavy-lift aircraft resources that are expensive and difficult to schedule. Indeed, US soil moisture campaigns, have been constrained by these factors, and European campaigns have used non-imagers due to instrument and aircraft size constraints. Despite these factors, these campaigns established that large-scale soil moisture remote sensing was possible, laying the groundwork for satellite missions. Starting in 2005, a series of airborne field campaigns have been conducted in Australia: to improve our understanding of soil moisture remote sensing at large scales over heterogeneous areas. These field data have been used to test and refine retrieval algorithms for soil moisture satellite missions, and most recently with the launch of the European Space Agency's Soil Moisture Ocean Salinity (SMOS) mission, to provide validation measurements over a multi-pixel area. The campaigns to date have included a preparatory campaign in 2005, two National Airborne Field Experiments (NAFE), (2005 and 2006), two campaigns to the Simpson Desert (2008 and 2009), and one Australian Airborne Cal/val Experiment for SMOS (AACES), just concluded in the austral spring of 2010. The primary airborne sensor for each campaign has been the Polarimetric L-band Microwave Radiometer (PLMR), a 6-beam pushbroom imager that is small enough to be compatible with light aircraft, greatly facilitating the execution of the series of campaigns, and a key to their success. An

  12. Squid based beam current meter

    International Nuclear Information System (INIS)

    Kuchnir, M.

    1983-01-01

    A SQUID based beam current meter has the capability of measuring the current of a beam with as little as 30 x 155 antiprotons (with a signal to noise ratio of 2). If low noise dc current is used to cancel most of the beam or an up-down counter is used to count auto-resets this sensitivity will be available at any time in the acumulation process. This current meter will therefore be a unique diagnostic tool for optimizing the performance of several Tev I components. Besides requiring liquid helium it seems that its only drawback is not to follow with the above sensitivity a sudden beam change larger than 16 μA, something that could be done using a second one in a less sensitive configuration

  13. Response of bacteria in wastewater sludge to moisture loss by evaporation and effect of moisture content on bacterial inactivation by ionizing radiation.

    OpenAIRE

    Ward, R L; Yeager, J G; Ashley, C S

    1981-01-01

    Two studies were carried out to determine the influence of moisture content of the survival of bacteria in raw wastewater sludge. The first study involved the effect of water loss by evaporation on the bacterial population. The second used these dewatered samples to measure the effects of moisture content on the inactivation of bacteria sludge by ionizing radiation. Both studies involved survival measurements of six representative fecally associated bacteria grown separately in sterilized slu...

  14. The application of CPLD in online nuclear detection meter of ore grade

    International Nuclear Information System (INIS)

    Yin Yiqiang; Yin Deyou; Gong Yalin; Shang Qingmin; Xiao Xiandong; Zhou Hongjun; Yu Haiming

    2010-01-01

    The pulse height analysis circuit for nuclear pulse signals is an important function cell of online nuclear detection meter, requiring high speed and credible logic circuit to eliminate the signal pileup rejection, overload detection, instrumentation measurement dead time on the adverse effects of spectrum. In order to improve the performance of nuclear detection meter, some function circuits are used, such as live time offset, overload detection and pileup rejection. The CPLD and multi single-channel spectrum measurement method used in ore grade nuclear instrumentation, eliminating the pileup, overload signal and accurately compensated the measurement of dead time, thus the circuit functions above are carried out credibly and the meter detection accuracy is improved drastically. (authors)

  15. Soil moisture mapping in torrential headwater catchments using a local interpolation method (Draix-Bléone field observatory, South Alps, France)

    Science.gov (United States)

    Mallet, Florian; Marc, Vincent; Douvinet, Johnny; Rossello, Philippe; Le Bouteiller, Caroline; Malet, Jean-Philippe

    2016-04-01

    Soil moisture is a key parameter that controls runoff processes at the watershed scale. It is characterized by a high area and time variability, controlled by site properties such as soil texture, topography, vegetation cover and climate. Several recent studies showed that changes in water storage was a key variable to understand the distribution of water residence time and the shape of flood's hydrograph (McDonnell and Beven, 2014; Davies and Beven, 2015). Knowledge of high frequency soil moisture variation across scales is a prerequisite for better understanding the areal distribution of runoff generation. The present study has been carried out in the torrential Draix-Bléone's experimental catchments, where water storage processes are expected to occur mainly on the first meter of soil. The 0,86 km2 Laval marly torrential watershed has a peculiar hydrological behavior during flood events with specific discharge among the highest in the world. To better understand the Laval internal behavior and to identify explanatory parameters of runoff generation, additional field equipment has been setup in sub-basins with various land use and morphological characteristics. From fall 2015 onwards this new instrumentation helped to supplement the routine measurements (rainfall rate, streamflow) and to develop a network of high frequency soil water content sensors (moisture probes, mini lysimeter). Data collected since early May and complementary measurement campaigns (itinerant soil moisture measurements, geophysical measurements) make it now possible to propose a soil water content mapping procedure. We use the LISDQS spatial extrapolation model based on a local interpolation method (Joly et. al, 2008). The interpolation is carried out from different geographical variables which are derived from a high resolution DEM (1m LIDAR) and a land cover image. Unlike conventional interpolation procedure, this method takes into account local forcing parameters such as slope, aspect

  16. Development and evaluation of an ultrasonic ground water seepage meter.

    Science.gov (United States)

    Paulsen, R J; Smith, C F; O'Rourke, D; Wong, T F

    2001-01-01

    Submarine ground water discharge can influence significantly the near-shore transport and flux of chemicals into the oceans. Quantification of the sources and rates of such discharge requires a ground water seepage meter that provides continuous measurements at high resolution over an extended period of time. An ultrasonic flowmeter has been adapted for such measurements in the submarine environment. Connected to a steel collection funnel, the meter houses two piezoelectric transducers mounted at opposite ends of a cylindrical flow tube. By monitoring the perturbations of fluid flow on the propagation of sound waves inside the flow tube, the ultrasonic meter can measure both forward and reverse fluid flows in real time. Laboratory and field calibrations show that the ultrasonic meter can resolve ground water discharges on the order of 0.1 microm/sec, and it is sufficiently robust for deployment in the field for several days. Data from West Neck Bay, Shelter Island, New York, elucidate the temporal and spatial heterogeneity of submarine ground water discharge and its interplay with tidal loading. A negative correlation between the discharge and tidal elevation was generally observed. A methodology was also developed whereby data for the sound velocity as a function of temperature can be used to infer the salinity and source of the submarine discharge. Independent measurements of electrical conductance were performed to validate this methodology.

  17. Compact Mass Flow Meter Based on a Micro Coriolis Flow Sensor

    Directory of Open Access Journals (Sweden)

    Remco Wiegerink

    2013-03-01

    Full Text Available In this paper we demonstrate a compact ready-to-use micro Coriolis mass flow meter. The full scale flow is 1 g/h (for water at a pressure drop < 1 bar. It has a zero stability of 2 mg/h and an accuracy of 0.5% reading for both liquids and gases. The temperature drift between 10 and 50 °C is below 1 mg/h/°C. The meter is robust, has standard fluidic connections and can be read out by means of a PC or laptop via USB. Its performance was tested for several common gases (hydrogen, helium, nitrogen, argon and air and liquids (water and isopropanol. As in all Coriolis mass flow meters, the meter is also able to measure the actual density of the medium flowing through the tube. The sensitivity of the measured density is ~1 Hz.m3/kg.

  18. Moisture Management for High R-Value Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lepage, R.; Schumacher, C.; Lukachko, A.

    2013-11-01

    The following report explains the moisture-related concerns for High R-value wall assemblies and discusses past Building America research work that informs this study. Hygrothermal simulations were prepared for several common approaches to High R-value wall construction in six cities (Houston, Atlanta, Seattle, St. Louis, Chicago, and International Falls) representing a range of climate zones (2, 3, 4C, 4, 5A, and 7, respectively). The simulations are informed by experience gained from past research in this area and validated by field measurement and forensic experience. The modeling program was developed to assess the moisture durability of the wall assemblies based on three primary sources of moisture: construction moisture, air leakage condensation, and bulk water leakage. The peak annual moisture content of the wood based exterior sheathing was used to comparatively analyze the response to the moisture loads for each of the walls in each given city. Walls which experienced sheathing moisture contents between 20% and 28% were identified as risky, whereas those exceeding 28% were identified as very high risk. All of the wall assemblies perform well under idealized conditions. However, only the walls with exterior insulation, or cavity insulation which provides a hygrothermal function similar to exterior insulation, perform adequately when exposed to moisture loads. Walls with only cavity insulation are particularly susceptible to air leakage condensation. None of the walls performed well when a precipitation based bulk water leak was introduced to the backside of the sheathing, emphasizing the importance of proper flashing details.

  19. Optimum moisture levels for biodegradation of mortality composting envelope materials.

    Science.gov (United States)

    Ahn, H K; Richard, T L; Glanville, T D

    2008-01-01

    Moisture affects the physical and biological properties of compost and other solid-state fermentation matrices. Aerobic microbial systems experience different respiration rates (oxygen uptake and CO2 evolution) as a function of moisture content and material type. In this study the microbial respiration rates of 12 mortality composting envelope materials were measured by a pressure sensor method at six different moisture levels. A wide range of respiration (1.6-94.2mg O2/g VS-day) rates were observed for different materials, with alfalfa hay, silage, oat straw, and turkey litter having the highest values. These four envelope materials may be particularly suitable for improving internal temperature and pathogen destruction rates for disease-related mortality composting. Optimum moisture content was determined based on measurements across a range that spans the maximum respiration rate. The optimum moisture content of each material was observed near water holding capacity, which ranged from near 60% to over 80% on a wet basis for all materials except a highly stabilized soil compost blend (optimum around 25% w.b.). The implications of the results for moisture management and process control strategies during mortality composting are discussed.

  20. Continuous data assimilation for downscaling large-footprint soil moisture retrievals

    KAUST Repository

    Altaf, M. U.

    2016-09-01

    Soil moisture is a crucial component of the hydrologic cycle, significantly influencing runoff, infiltration, recharge, evaporation and transpiration processes. Models characterizing these processes require soil moisture as an input, either directly or indirectly. Better characterization of the spatial variability of soil moisture leads to better predictions from hydrologic/climate models. In-situ measurements have fine resolution, but become impractical in terms of coverage over large extents. Remotely sensed data have excellent spatial coverage extents, but suffer from poorer spatial and temporal resolution. We present here an innovative approach to downscaling coarse resolution soil moisture data by combining data assimilation and physically based modeling. In this approach, we exploit the features of Continuous Data Assimilation (CDA). A nudging term, estimated as the misfit between interpolants of the assimilated coarse grid measurements and the fine grid model solution, is added to the model equations to constrain the model’s large scale variability by available measurements. Soil moisture fields generated at a fine resolution by a physically-based vadose zone model (e.g., HYDRUS) are subjected to data assimilation conditioned upon the coarse resolution observations. This enables nudging of the model outputs towards values that honor the coarse resolution dynamics while still being generated at the fine scale. The large scale features of the model output are constrained to the observations, and as a consequence, the misfit at the fine scale is reduced. The advantage of this approach is that fine resolution soil moisture maps can be generated across large spatial extents, given the coarse resolution data. The data assimilation approach also enables multi-scale data generation which is helpful to match the soil moisture input data to the corresponding modeling scale. Application of this approach is likely in generating fine and intermediate resolution soil