WorldWideScience

Sample records for modification kit verification

  1. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PERFORMANCE TESTING OF THE INDUSTRIAL TEST SYSTEM, INC. CYANIDE REAGENTSTRIP™ TEST KIT

    Science.gov (United States)

    Cyanide can be present in various forms in water. The cyanide test kit evaluated in this verification study (Industrial Test System, Inc. Cyanide Regent Strip ™ Test Kit) was designed to detect free cyanide in water. This is done by converting cyanide in water to cyanogen...

  2. Design and verification of computer-based reactor control system modification at Bruce-A candu nuclear generating station

    International Nuclear Information System (INIS)

    Basu, S.; Webb, N.

    1995-01-01

    The Reactor Control System at Bruce-A Nuclear Generating Station is going through some design modifications, which involve a rigorous design process including independent verification and validation. The design modification includes changes to the control logic, alarms and annunciation, hardware and software. The design (and verification) process includes design plan, design requirements, hardware and software specifications, hardware and software design, testing, technical review, safety evaluation, reliability analysis, failure mode and effect analysis, environmental qualification, seismic qualification, software quality assurance, system validation, documentation update, configuration management, and final acceptance. (7 figs.)

  3. Electric and mechanical basic parameters to elaborate a process for a technical verification of safety related design modifications

    International Nuclear Information System (INIS)

    Lamuno Fernandez, Mercedes; La Roca Mallofre, GISEL; Bano Azcon, Alberto

    2010-01-01

    This paper presents a systematic process to check a design in order to achieve all the requirements that regulations demand. Nuclear engineers must verify that a design is done according to the safety requirements, and this paper presents how we have elaborated a process to improve the technical project verification. For a faster, better and easier verification process, here we summarize how to select the electric and mechanical basic parameters, which ensure the correct project verification of safety related design modifications. This process considers different aspects, which guarantee that the design preserves the availability, reliability and functional capability of the Structures, Systems and Components needed to operate the Nuclear Power Station with security. Electric and mechanical reference parameters are identified and discussed as well as others related ones, which are critical to safety. The implementation procedure to develop tasks performed in any company that has a quality plan is a requirement. On the engineering business, it is important not to use the personal criteria to do a technical analysis of a project; although, many times it is the checker's criteria and knowledge responsibility to ensure the correct development of a design modification. Then, the checker capabilities are the basis of the modification verification. This kind of procedure's development is not easy, because in an engineering project with important technical contents, there are multiple scenarios, but lots of them have a common basis. If we can identify the technical common basis of these projects, we will make good project verification but there are many difficulties we can encounter along this process. (authors)

  4. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.

  5. The need for standardization of methodology and components in commercial radioimmunoassay kits

    International Nuclear Information System (INIS)

    Wood, W.G.; Marschner, I.; Scriba, P.C.

    1978-01-01

    The problems arising from the increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. These problems differ according to the substance under test. The quality of individual reagents is often good, but the methodology is often not optimal and may contain short-cuts which, although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modifications in the methodology often lead to big improvements in sensitivity and precision. This has been demonstrated in three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that with many quality-control sera imported from the USA no values are ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The study underlines the need to standardize kit components and assay methods to enable the results obtained by different laboratories with different kits to be compared. (author)

  6. 49 CFR 173.161 - Chemical kits and first aid kits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  7. Need for standardization of methodology and components in commercial radioimmunoassay kits

    Energy Technology Data Exchange (ETDEWEB)

    Wood, W G; Marschner, I; Scriba, P C [Muenchen Univ. (Germany, F.R.). Medizinische Klinik Innenstadt

    1977-01-01

    The problems arising from increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. The problems arising in various RIAs differ according to the substance under test. The quality of individual components is often good, although methodology is often not optimal and contains short-cuts, which although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modification of methodology often leads to major improvements in sensitivity and precision, and this has been demonstrated in the case of three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that in many imported quality control sera from the USA no values have been ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The deductions from this study are that a standardization of kit components and assay methods is desirable in order to allow comparison of results between laboratories using different kits.

  8. Fabrication of CANFLEX bundle kit for irradiation test in NRU

    International Nuclear Information System (INIS)

    Cho, Moon Sung; Kwon, Hyuk Il; Ji, Chul Goo; Chang, Ho Il; Sim, Ki Seob; Suk, Ho Chun.

    1997-10-01

    CANFLEX bundle kit was prepared at KAERI for the fabrication of complete bundle at AECL. Completed bundle will be used for irradiation test in NRU. Provisions in the 'Quality Assurance Manual for HWR Fuel Projects,' 'Manufacturing Plan' and 'Quality Verification, Inspection and Test Plan' were implemented as appropriately for the preparation of CANFLEX kit. A set of CANFLEX kit consist of 43 fuel sheath of two different sizes with spacers, bearing pads and buttons attached, 2 pieces of end plates and 86 pieces of end caps with two different sizes. All the documents utilized as references for the fabrication such as drawings, specifications, operating instructions, QC instructions and supplier's certificates are specified in this report. Especially, suppliers' certificates and inspection reports for the purchased material as well as KAERI's inspection report are integrated as attachments to this report. Attached to this report are supplier's certificates and KAERI inspection reports for the procured materials and KAERI QC inspection reports for tubes, pads, spacers, buttons, end caps, end plates and fuel sheath. (author). 37 refs

  9. Aircraft Modifications: Assessing the Current State of Air Force Aircraft Modifications and the Implications for Future Military Capability

    Science.gov (United States)

    2007-01-25

    J IVF MNA M J J DA S 0 TM C J JV A i KIT DELIVERYO TYS h. KIT INSTALL OTYS-DEPOT JI I- - - 1. KIT INSTALL OTYS-TEAM 24. INFLATED COST SUMMgARIES BY...as a part of a study examining the costing of modifying Air Force weapon systems. Over the same time that the concept for this dissertation was...planning and modernization. The project documented here was conducted within the Costing of Modifications and Upgrades program of RAND’s Project AIR

  10. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  11. The need for standardisation of methodology and components in commercial radioimmunoassay kits

    International Nuclear Information System (INIS)

    Wood, W.G.; Marschner, I.; Scriba, P.C.

    1977-01-01

    The problems arising from increasing use of commercial kits in radioimmunoassay (RIA) and related fields are discussed. The problems arising in various RIAs differ according to the substance under test. The quality of individual components is often good, although methodology is often not optimal and contains short-cuts, which although commercially attractive, can lead to erroneous values and poor sensitivity and precision. Minor modification of methodology often leads to major improvements in sensitivity and precision, and this has been demonstrated in the case of three digoxin kits employing antibody-coated tube techniques and in four kits for thyrotropin (TSH) using different techniques. It has also been noted that in many imported quality control sera from the USA no values have been ascribed to European kits for the components listed, thus reducing these sera to the function of precision control. The deductions from this study are that a standardisation of kit components and assay methods is desirable in order to allow comparison of results between laboratories using different kits. (orig.) [de

  12. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    Science.gov (United States)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of

  13. Field test for treatment verification of an in-situ enhanced bioremediation study

    International Nuclear Information System (INIS)

    Taur, C.K.; Chang, S.C.

    1995-01-01

    Due to a leakage from a 12-inch pressurized diesel steel pipe four years ago, an area of approximately 30,000 square meters was contaminated. A pilot study applying the technology of in-situ enhanced bioremediation was conducted. In the study, a field test kit and on-site monitoring equipment were applied for site characterization and treatment verification. Physically, the enhanced bioremediation study consisted of an air extraction and air supply system, and a nutrition supply network. Certain consistent sampling methodology was employed. Progress was verified by daily monitoring and monthly verification. The objective of this study was to evaluate the capabilities of indigenous microorganisms to biodegrade the petroleum hydrocarbons with provision of oxygen and nutrients. Nine extraction wells and eight air sparging wells were installed. The air sparging wells injected the air into geoformation and the extraction wells provided the underground air circulation. The soil samples were obtained monthly for treatment verification by a Minuteman drilling machine with 2.5-foot-long hollow-stem augers. The samples were analyzed on site for TPH-diesel concentration by a field test kit manufactured by HNU-Hanby, Houston, Texas. The analytical results from the field test kit were compared with the results from an environmental laboratory. The TVPH concentrations of the air extracted from the vadose zone by a vacuum blower and the extraction wells were routinely monitored by a Foxboro FID and Cosmos XP-311A combustible air detector. The daily monitoring of TVPH concentrations provided the reliable data for assessing the remedial progress

  14. Telescope Kits: A Teaching Vehicle for the International Year of Astronomy

    Science.gov (United States)

    Pompea, Stephen M.; Fienberg, R. T.; Isbell, D.; Deustua, S.

    2007-12-01

    We are examining a variety of telescope kits suitable for assembly by school-age children in order to design a cornerstone educational program for the International Year of Astronomy 2009-400 years after Galileo's observations. In our experience, telescope kits are superior to pre-assembled telescopes for use in an educational setting as the students feels a stronger sense of ownership and have a better understanding of the components and how they work. We examined several low to medium power refracting telescope kits including one kit used in the Hands-On Optics project at NOAO. We describe the advantages and disadvantages of each kit from an educational and optical perspective and what modifications may be made to enhance their educational utility. We also describe the optical and education requirements for a low-powered "Galileoscope", to be distributed widely during the IYA. We also describe how the "Galileoscope” will be embedded in an educational program disseminated through science centers, amateur astronomy clubs and other Hands-On Optics centers and partners.

  15. Training Educators to Teach the Sun and Space Weather Using a Kit of Tools

    Science.gov (United States)

    Keesee, A. M.; Ensign, T.

    2014-12-01

    NASA provides a wealth of data from Heliospheric missions to the public, but educators face several challenges to using such data in the classroom. These include the knowledge of what is available and how to use it, a full understanding of the science concepts the data demonstrate, ability to obtain and maintain products to access data, and access to technology (such as computer labs) for anything other than testing. To surmount these challenges, the Educator Resource Center at the NASA Independent Validation and Verification (IV&V) Center in Fairmont, WV has developed an operational model that focuses on housing, maintaining, and lending out kits of necessary equipment along with training educators in the science concepts and use of kit materials. Following this model, we have developed a Sun and Space Weather kit and an educator professional development course that we have presented several times. The kit includes a classroom set of iPads utilized to access data from NASA missions and other sources as well as create video reports for project based outcomes, a set of telescopes for safe solar viewing, and materials to explore magnetic fields and the electromagnetic spectrum. We will present an overview of the training course, the kit materials, and lessons learned.

  16. Feasibility of biochemical verification in a web-based smoking cessation study.

    Science.gov (United States)

    Cha, Sarah; Ganz, Ollie; Cohn, Amy M; Ehlke, Sarah J; Graham, Amanda L

    2017-10-01

    Cogent arguments have been made against the need for biochemical verification in population-based studies with low-demand characteristics. Despite this fact, studies involving digital interventions (low-demand) are often required in peer review to report biochemically verified abstinence. To address this discrepancy, we examined the feasibility and costs of biochemical verification in a web-based study conducted with a national sample. Participants were 600U.S. adult current smokers who registered on a web-based smoking cessation program and completed surveys at baseline and 3months. Saliva sampling kits were sent to participants who reported 7-day abstinence at 3months, and analyzed for cotinine. The response rate at 3-months was 41.2% (n=247): 93 participants reported 7-day abstinence (38%) and were mailed a saliva kit (71% returned). The discordance rate was 36.4%. Participants with discordant responses were more likely to report 3-month use of nicotine replacement therapy or e-cigarettes than those with concordant responses (79.2% vs. 45.2%, p=0.007). The total cost of saliva sampling was $8280 ($125/sample). Biochemical verification was both time- and cost-intensive, and yielded a relatively small number of samples due to low response rates and use of other nicotine products during the follow-up period. There was a high rate of discordance of self-reported abstinence and saliva testing. Costs for data collection may be prohibitive for studies with large sample sizes or limited budgets. Our findings echo previous statements that biochemical verification is not necessary in population-based studies, and add evidence specific to technology-based studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. [Application of DNA extraction kit, 'GM quicker' for detection of genetically modified soybeans].

    Science.gov (United States)

    Sato, Noriko; Sugiura, Yoshitsugu; Tanaka, Toshitsugu

    2012-01-01

    Several DNA extraction methods have been officially introduced to detect genetically modified soybeans, but the choice of DNA extraction kits depend on the nature of the samples, such as grains or processed foods. To overcome this disadvantage, we examined whether the GM quicker kit is available for both grains and processed foods. We compared GM quicker with four approved DNA extraction kits in respect of DNA purity, copy numbers of lectin gene, and working time. We found that the DNA quality of GM quicker was superior to that of the other kits for grains, and the procedure was faster. However, in the case of processed foods, GM quicker was not superior to the other kits. We therefore investigated an unapproved GM quicker 3 kit, which is available for DNA extraction from processed foods, such as tofu and boiled soybeans. The GM quicker 3 kit provided good DNA quality from both grains and processed foods, so we made a minor modification of the GM quicker-based protocol that was suitable for processed foods, using GM quicker and its reagents. The modified method enhanced the performance of GM quicker with processed foods. We believe that GM quicker with the modified protocol is an excellent tool to obtain high-quality DNA from grains and processed foods for detection of genetically modified soybeans.

  18. Canister Storage Building Receiving Pit Modification Informal Design Verification

    International Nuclear Information System (INIS)

    KRIEG, S.A.

    2000-01-01

    The design for modifications to the CSB Cask Receiving pit guides was verified by the informal design verification (meeting) method on August 9, 2000. The invited list of attendees and the meeting attendance sheet are included in attachment 1. The design modifications that were reviewed are documented in ECN 654484 (attachment 2). The requirement that the design is to be verified against is to ''center the transportation cask sufficiently to allow installation of the guide funnel on the cask (± 0.25 inches or less)''. The alternatives considered are detailed in attachment 3. Alternative number 4, ''Modify The Pit Guides'', was determined to be the preferred alternative primarily due to considerations of simplicity, reliability, and low cost. Alternative 1, ''Rotate the impact Absorber 180 o '', was successfully performed but was considered a temporary fix that was not acceptable for a long term operational mode. The requirement to position the receiving crane accurately enough to lower the transportation cask into the pit with the redesigned guides was discussed and considered to be achievable without undue effort from the operator. The tolerance on the OD of the transfer cask was discussed (± 1/8 inch) relative to the clearance with the guides. As-built dimensions for the cask OD will be looked at to verify sufficient clearance exists with the maximum cask OD. The final design thickness of the shims under the guides will be based on the as-built cask OD dimensions and field measurements between the pit guides. The need for a ''plastic'' cover for the guides was discussed and deemed unnecessary. Thermal growth of the cask OD was calculated at 3-5 mils and considered insignificant. The possibility of reducing the OD of the guide funnel was reviewed but this was considered impractical due to the requirement for the MCO to miss the edge of the funnel in case of a MCO drop. One of the transportation casks have the lift trunions installed 3/8 inch off center. This is

  19. Transmutation Fuel Performance Code Thermal Model Verification

    Energy Technology Data Exchange (ETDEWEB)

    Gregory K. Miller; Pavel G. Medvedev

    2007-09-01

    FRAPCON fuel performance code is being modified to be able to model performance of the nuclear fuels of interest to the Global Nuclear Energy Partnership (GNEP). The present report documents the effort for verification of the FRAPCON thermal model. It was found that, with minor modifications, FRAPCON thermal model temperature calculation agrees with that of the commercial software ABAQUS (Version 6.4-4). This report outlines the methodology of the verification, code input, and calculation results.

  20. KIT safety management. Annual report 2013; KIT-Sicherheitsmanagement. Jahresbericht 2013

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Gerhard (ed.)

    2014-07-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for licensing procedures, industrial safety organization, control of environmental protection measures, planning and implementation of emergency preparedness and response, operation of radiological laboratories and measurement stations, extensive radiation protection support and the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2013. Status figures in principle reflect the status at the end of the year 2013. The processes described cover the areas of competence of KSM. Due to changes in the organization of the infrastructural service units in KIT, KSM has been cancelled at the end of 2013. Its tasks will mainly be covered in 2014 by the new founded service unit Safety and Environmental (Sicherheit und Umwelt, SUM). The departments Campus Security, Fire Brigade and Information Technology have been transferred to the Service Unit General Services (Allgemeine Services, ASERV).

  1. Investigation of a Verification and Validation Tool with a Turbofan Aircraft Engine Application

    Science.gov (United States)

    Uth, Peter; Narang-Siddarth, Anshu; Wong, Edmond

    2018-01-01

    The development of more advanced control architectures for turbofan aircraft engines can yield gains in performance and efficiency over the lifetime of an engine. However, the implementation of these increasingly complex controllers is contingent on their ability to provide safe, reliable engine operation. Therefore, having the means to verify the safety of new control algorithms is crucial. As a step towards this goal, CoCoSim, a publicly available verification tool for Simulink, is used to analyze C-MAPSS40k, a 40,000 lbf class turbo-fan engine model developed at NASA for testing new control algorithms. Due to current limitations of the verification software, several modifications are made to C-MAPSS40k to achieve compatibility with CoCoSim. Some of these modifications sacrifice fidelity to the original model. Several safety and performance requirements typical for turbofan engines are identified and constructed into a verification framework. Preliminary results using an industry standard baseline controller for these requirements are presented. While verification capabilities are demonstrated, a truly comprehensive analysis will require further development of the verification tool.

  2. KIT safety management. Annual report 2012; KIT-Sicherheitsmanagement. Jahresbericht 2012

    Energy Technology Data Exchange (ETDEWEB)

    Frank, Gerhard (ed.)

    2013-07-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for - licensing procedures, - industrial safety organization, - control of environmental protection measures, - planning and implementation of emergency preparedness and response, - operation of radiological laboratories and measurement stations, - extensive radiation protection support and the - the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its industrial safety management is certified by the VBG as ''AMS-Arbeitsschutz mit System'' and, hence, fulfills the requirements of NLF / ISO-OSH 2001. KSM laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2012. Status figures in principle reflect the status at the end of the year 2012. The processes described cover the areas of competence of KSM.

  3. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    Science.gov (United States)

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  4. The verification of DRAGON: progress and lessons learned

    International Nuclear Information System (INIS)

    Marleau, G.

    2002-01-01

    The general requirements for the verification of the legacy code DRAGON are somewhat different from those used for new codes. For example, the absence of a design manual for DRAGON makes it difficult to confirm that the each part of the code performs as required since these requirements are not explicitly spelled out for most of the DRAGON modules. In fact, this conformance of the code can only be assessed, in most cases, by making sure that the contents of the DRAGON data structures, which correspond to the output generated by a module of the code, contains the adequate information. It is also possible in some cases to use the self-verification options in DRAGON to perform additional verification or to evaluate, using an independent software, the performance of specific functions in the code. Here, we will describe the global verification process that was considered in order to bring DRAGON to an industry standard tool-set (IST) status. We will also discuss some of the lessons we learned in performing this verification and present some of the modification to DRAGON that were implemented as a consequence of this verification. (author)

  5. First aid kit

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001958.htm First aid kit To use the sharing features on this ... ahead, you can create a well-stocked home first aid kit. Keep all of your supplies in one ...

  6. Analysis of KIT expression and KIT exon 11 mutations in canine oral malignant melanomas.

    Science.gov (United States)

    Murakami, A; Mori, T; Sakai, H; Murakami, M; Yanai, T; Hoshino, Y; Maruo, K

    2011-09-01

    KIT, a transmembrane receptor tyrosine kinase, is one of the specific targets for anti-cancer therapy. In humans, its expression and mutations have been identified in malignant melanomas and therapies using molecular-targeted agents have been promising in these tumours. As human malignant melanoma, canine malignant melanoma is a fatal disease with metastases and the poor response has been observed with all standard protocols. In our study, KIT expression and exon 11 mutations in dogs with histologically confirmed malignant oral melanomas were evaluated. Although 20 of 39 cases were positive for KIT protein, there was no significant difference between KIT expression and overall survival. Moreover, polymerase chain reaction amplification and sequencing of KIT exon 11 in 17 samples did not detect any mutations and proved disappointing. For several reasons, however, KIT expression and mutations of various exons including exon 11 should be investigated in more cases. © 2011 Blackwell Publishing Ltd.

  7. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    Science.gov (United States)

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  8. Advantage of using a home-made elisa kit for detection of Helicobacter pylori infection over commercially imported kits

    Directory of Open Access Journals (Sweden)

    Mohammadi M

    2008-01-01

    Full Text Available Purpose: To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp infection and comparison of its immunologic criteria with those of foreign commercial kits. Methods: A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. Results: The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%, BIOHIT kit (72.4, 41.6 and 94.1% and HelicoBlot2.1 (94.2, 93.4 and 100%. Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Conclusions: Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  9. Exploit Kit traffic analysis

    OpenAIRE

    Καπίρης, Σταμάτης; Kapiris, Stamatis

    2017-01-01

    Exploit kits have become one of the most widespread and destructive threat that Internet users face on a daily basis. Since the first actor, which has been categorized as exploit kit, namely MPack, appeared in 2006, we have seen a new era on exploit kit variants compromising popular websites, infecting hosts and delivering destructive malware, following an exponentially evolvement to date. With the growing threat landscape, large enterprises to domestic networks, have starte...

  10. Quality control of radioimmunoassay kits of pituitary hormones; Control de calidad de kits de radioinmunoanalisis de hormonas hipofisiarias

    Energy Technology Data Exchange (ETDEWEB)

    Caso Pena, R [Centro de Isotopos, La Habana (Cuba); Arranz Calzado, C [Instituto Nacional de Endocrinologia, La Habana (Cuba)

    1998-12-31

    The present work describe the quality control procedures carried out on three RIA-Kits by the Isotopes Centre of Cuba, The subject matter of study were ;: were: LH-RIA-Kit, FSH-RIA-Kit and Prolactin- RIA -Kit. The controls have included the characterization of the {sup 125}I labelled hormones the specific antibodies, the 2 nd antibodies, the standards curves and the control serum. For the validation of these Kits were used reference standards from the WHO (World Health Organizations) and Kits from CIS company (France) based on the IRMA assays technologies . The results obtained allow us encourage the reliability of RIA-Kits

  11. Comparison of Thyroglobulin Measurements Using Three Different Immunoassay Kits: A BRAMHS Tg-Plus RIA Kit, a BRAMHS hTg Sensitive Kryptor Kit, and a Beckman Coulter ACCESS Immunoassay Kit

    Directory of Open Access Journals (Sweden)

    Mijin Kim

    2016-09-01

    Full Text Available BackgroundSecond-generation thyroglobulin immunometric assays (Tg-IMAs have been developed with improved sensitivity. Our aim was to compare the diagnostic value of Tg-IMA measurements using a Kryptor (BRAHMS AG kit (Tg-K and an ACCESS (Beckman Coulter kit (Tg-A with that of the first-generation Tg measurement using a Tg-plus (BRAHMS AG kit (Tg+.MethodsWe enrolled 82 differentiated thyroid cancer patients who underwent total thyroidectomy with radioactive iodine remnant ablation and who underwent diagnostic whole body scan using recombinant human thyroid stimulating hormone (rhTSH. The Tg+, Tg-K, and Tg-A were measured before rhTSH administration during levothyroxine treatment (suppressed Tg from the same sample. Serum Tg+ was measured after rhTSH stimulation (stimulated Tg.ResultsSuppressed Tg+ was more significantly correlated with suppressed Tg-K (R2=0.919, P<0.001 than with suppressed Tg-A (R2=0.536, P<0.001. The optimal cut-off values of suppressed Tg+, Tg-K, and Tg-A for predicting stimulated Tg+ of 1 ng/mL were 0.3, 0.2, and 0.2 ng/mL, respectively. The sensitivity, specificity, and accuracy of suppressed Tg+ were 67%, 100%, and 90%, respectively; those of suppressed Tg-K were 83%, 90%, and 88%; those of suppressed Tg-A were 96%, 82%, and 87%, respectively. The positive predictive and negative predictive values of Tg+ were 100% and 87%, respectively; those of Tg-K were 79% and 92%; and those of Tg-A were 73% and 98%.ConclusionWe could not clearly demonstrate which kit had better diagnostic performance after comparison of first-generation Tg measurements with Tg-IMA measurements. Also, there were kit-to-kit variations between Tg-IMA kits. Suppressed Tg measured by Tg-IMA was insufficient to completely substitute for a stimulated Tg measurement.

  12. Benchmarking Tool Kit.

    Science.gov (United States)

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  13. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  14. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    Science.gov (United States)

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  15. Create an Emergency Kit

    Science.gov (United States)

    ... models take up less space in your kit. Cell phone. Always carry a cell phone and let people know where you are going ... pump in your emergency kit. Remember that despite safety standards and careful monitoring, these devices can fail. ...

  16. Education Payload Operation - Kit D

    Science.gov (United States)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Kit D (EPO-Kit D) includes education items that will be used to support the live International Space Station (ISS) education downlinks and Education Payload Operation (EPO) demonstrations onboard the ISS. The main objective of EPO-Kit D supports the National Aeronautics and Space Administration (NASA) goal of attracting students to study and seek careers in science, technology, engineering, and mathematics.

  17. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    Science.gov (United States)

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart

  18. Molecular Alterations of KIT Oncogene in Gliomas

    Directory of Open Access Journals (Sweden)

    Ana L. Gomes

    2007-01-01

    Full Text Available Gliomas are the most common and devastating primary brain tumours. Despite therapeutic advances, the majority of gliomas do not respond either to chemo or radiotherapy. KIT, a class III receptor tyrosine kinase (RTK, is frequently involved in tumourigenic processes. Currently, KIT constitutes an attractive therapeutic target. In the present study we assessed the frequency of KIT overexpression in gliomas and investigated the genetic mechanisms underlying KIT overexpression. KIT (CD117 immunohistochemistry was performed in a series of 179 gliomas of various grades. KIT activating gene mutations (exons 9, 11, 13 and 17 and gene amplification analysis, as defined by chromogenic in situ hybridization (CISH and quantitative real-time PCR (qRT-PCR were performed in CD117 positive cases. Tumour cell immunopositivity was detected in 15.6% (28/179 of cases, namely in 25% (1/4 of pilocytic astrocytomas, 25% (5/20 of diffuse astrocytomas, 20% (1/5 of anaplastic astrocytomas, 19.5% (15/77 of glioblastomas and one third (3/9 of anaplastic oligoastrocytomas. Only 5.7% (2/35 of anaplastic oligodendrogliomas showed CD117 immunoreactivity. No association was found between tumour CD117 overexpression and patient survival. In addition, we also observed CD117 overexpression in endothelial cells, which varied from 0–22.2% of cases, being more frequent in high-grade lesions. No KIT activating mutations were identified. Interestingly, CISH and/or qRT-PCR analysis revealed the presence of KIT gene amplification in 6 glioblastomas and 2 anaplastic oligoastrocytomas, corresponding to 33% (8/24 of CD117 positive cases. In conclusion, our results demonstrate that KIT gene amplification rather than gene mutation is a common genetic mechanism underlying KIT expression in subset of malignant gliomas. Further studies are warranted to determine whether glioma patients exhibiting KIT overexpression and KIT gene amplification may benefit from therapy with anti-KIT RTK

  19. Radiology seminars using teaching kits

    International Nuclear Information System (INIS)

    Munro, T.G.

    1989-01-01

    Clinco-radiological seminars are an effective method of teaching medical students. However, in busy departments it is often difficult to provide enough radiologists for small group instruction. This can be facilitated by the use of prepared teaching kits. Each kit contains a set of duplicated films and a syllabus which gives a short clinical history for each patient and a series of questions to be used to direct the discussion. Each diagnostic problem is chosen to demonstrate core material. We have been using these teaching kits for organ system teaching in the preclerkship year. Teaching kits offer several advantages. They make it easier to recruit seminar leaders through efficient use of their time. The use of duplicated films and a syllabus ensures that all students cover the same material. The syllabus can be used to generate examination questions for reinforcement of important concepts. The kits are also available to students to review alone and can be readily updated as required

  20. SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

    Energy Technology Data Exchange (ETDEWEB)

    Xie, X; Cao, D; Housley, D; Mehta, V; Shepard, D [Swedish Cancer Institute, Seattle, WA (United States)

    2014-06-01

    Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

  1. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  2. 46 CFR 184.710 - First-aid kits.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  3. Quality control of radioimmunoassay kits of pituitary hormones

    International Nuclear Information System (INIS)

    Caso Pena, R.; Arranz Calzado, C.

    1997-01-01

    The present work describe the quality control procedures carried out on three RIA-Kits by the Isotopes Centre of Cuba, The subject matter of study were ;: were: LH-RIA-Kit, FSH-RIA-Kit and Prolactin- RIA -Kit. The controls have included the characterization of the 125 I labelled hormones the specific antibodies, the 2 nd antibodies, the standards curves and the control serum. For the validation of these Kits were used reference standards from the WHO (World Health Organizations) and Kits from CIS company (France) based on the IRMA assays technologies . The results obtained allow us encourage the reliability of RIA-Kits

  4. 46 CFR 121.710 - First-aid kits.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit... kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A...

  5. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    Science.gov (United States)

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  6. ISS Expedition 08 Press Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — Press kit for ISS mission Expedition 08 from 10/2003-04/2004. Press kits contain information about each mission overview, crew, mission timeline, benefits, and media...

  7. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  8. Build an Emergency Preparedness Kit

    Science.gov (United States)

    ... In addition to the items listed above, a vehicle kit should include: -fire extinguisher. -booster cables and tow rope. -compass and road maps. -shovel. -tire repair kit and pump. -extra clothing to keep dry. - ...

  9. Improved kit formulation for preparation of (99m)Tc-HYNIC-TOC: results of preliminary clinical evaluation in imaging patients with neuroendocrine tumors.

    Science.gov (United States)

    Korde, Aruna; Mallia, Madhava; Shinto, Ajit; Sarma, H D; Samuel, Grace; Banerjee, Sharmila

    2014-11-01

    (99m)Tc-HYNIC-TOC is a cost-effective and logistically viable agent for scintigraphy of neuroendocrine tumors overexpressing somatostatin receptors as compared with [(111)In-DTPA-D-Phe(1)] Octreotide (Octreoscan(®)). Several studies have been reported, wherein the efficacy of this agent is demonstrated. In the present article, the authors report the preparation of a single-vial HYNIC-TOC kit suitable for the preparation of 4-5 patient doses (15 mCi/patient) of (99m)Tc-HYNIC-TOC. The kits were tested for sterility and bacterial endotoxins to assure safety of the product. A significant modification in this kit is the inclusion of buffer in the kit itself, unlike in commercially available kits where the buffer solution has to be added during preparation. (99m)Tc-HYNIC-TOC was prepared by adding 20-80 mCi (740-2960 MBq) of freshly eluted Na(99m)TcO4 in 1-3 mL of sterile saline directly into the kit vial and heating the vial in a water bath at 100°C for 20 minutes. The labeling yield and radiochemical purity of (99m)Tc-HYNIC-TOC, prepared using the lyophilized cold kit, were consistently >90%. The kits were evaluated over a period of 9 months and found to be stable when stored at -20°C. Limited clinical studies performed with the (99m)Tc-HYNIC-TOC, formulated using the kit, showed adequate sensitivity and specificity for the detection of gasteroenteropancreatic neuroendocrine tumors.

  10. Development of an add-on kit for scanning confocal microscopy (Conference Presentation)

    Science.gov (United States)

    Guo, Kaikai; Zheng, Guoan

    2017-03-01

    Scanning confocal microscopy is a standard choice for many fluorescence imaging applications in basic biomedical research. It is able to produce optically sectioned images and provide acquisition versatility to address many samples and application demands. However, scanning a focused point across the specimen limits the speed of image acquisition. As a result, scanning confocal microscope only works well with stationary samples. Researchers have performed parallel confocal scanning using digital-micromirror-device (DMD), which was used to project a scanning multi-point pattern across the sample. The DMD based parallel confocal systems increase the imaging speed while maintaining the optical sectioning ability. In this paper, we report the development of an add-on kit for high-speed and low-cost confocal microscopy. By adapting this add-on kit to an existing regular microscope, one can convert it into a confocal microscope without significant hardware modifications. Compared with current DMD-based implementations, the reported approach is able to recover multiple layers along the z axis simultaneously. It may find applications in wafer inspection and 3D metrology of semiconductor circuit. The dissemination of the proposed add-on kit under $1000 budget could also lead to new types of experimental designs for biological research labs, e.g., cytology analysis in cell culture experiments, genetic studies on multicellular organisms, pharmaceutical drug profiling, RNA interference studies, investigation of microbial communities in environmental systems, and etc.

  11. Collimator kit

    International Nuclear Information System (INIS)

    Jonker, R.R.

    1976-01-01

    A collimator kit having a number of parts which may be assembled in various combinations to provide focusing collimators with different performance characteristics for radioisotope imaging apparatus is described

  12. KIT safety management. Annual report 2012

    International Nuclear Information System (INIS)

    Frank, Gerhard

    2013-01-01

    The KIT Safety Management Service Unit (KSM) guarantees radiological and conventional technical safety and security of Karlsruhe Institute of Technology and controls the implementation and observation of legal environmental protection requirements. KSM is responsible for - licensing procedures, - industrial safety organization, - control of environmental protection measures, - planning and implementation of emergency preparedness and response, - operation of radiological laboratories and measurement stations, - extensive radiation protection support and the - the execution of security tasks in and for all organizational units of KIT. Moreover, KSM is in charge of wastewater and environmental monitoring for all facilities and nuclear installations all over the KIT campus. KSM is headed by the Safety Commissioner of KIT, who is appointed by the Presidential Committee. Within his scope of procedure for KIT, the Safety Commissioner controls the implementation of and compliance with safety-relevant requirements. The KIT Safety Management is certified according to DIN EN ISO 9001, its industrial safety management is certified by the VBG as ''AMS-Arbeitsschutz mit System'' and, hence, fulfills the requirements of NLF / ISO-OSH 2001. KSM laboratories are accredited according to DIN EN ISO/IEC 17025. To the extent possible, KSM is committed to maintaining competence in radiation protection and to supporting research and teaching activities. The present reports lists the individual tasks of the KIT Safety Management and informs about the results achieved in 2012. Status figures in principle reflect the status at the end of the year 2012. The processes described cover the areas of competence of KSM.

  13. c-KIT positive schistosomal urinary bladder carcinoma are frequent but lack KIT gene mutations.

    Science.gov (United States)

    Shams, Tahany M; Metawea, Mokhtar; Salim, Elsayed I

    2013-01-01

    Urinary bladder squamous cell carcinoma (SCC), one of the most common neoplasms in Egypt, is attributed to chronic urinary infection with Schistosoma haematobium (Schistosomiasis). The proto-oncogene c-KIT, encoding a tyrosine kinase receptor and implicated in the development of a number of human malignancies, has not been studied so far in schistosomal urinary bladder SCCs. We therefore determined immunohistochemical (IHC) expression of c-KIT in paraffin sections from 120 radical cystectomies of SCCs originally obtained from the Pathology Department of Suez Canal University (Ismailia, Egypt). Each slide was evaluated for staining intensity where the staining extent of >10% of cells was considered positive. c-KIT overexpression was detected in 78.3% (94/120) of the patients, the staining extents in the tumor cells were 11-50% and >50% in 40 (42.6%) and 54 (57.4%) respectively. The positive cases had 14.9%, 63.8%, 21.3% as weak, moderate and strong intensity respectively. Patients with positive bilharzial ova had significantly higher c-KIT expression than patients without (95.2% vs. 38.9%, P=0.000). Mutation analysis of exons 9-13 was negative in thirty KIT positive cases. The high rate of positivity in SBSCC was one of the striking findings; However, CD117 may be a potential target for site specific immunotherapy to improve the outcome of this tumor.

  14. Preparation of kits for 99Tcm radiopharmaceuticals

    International Nuclear Information System (INIS)

    1992-05-01

    This publication details preparation under Good Manufacturing Practices (GMP) of thirteen widely used 99 Tc m radiopharmaceuticals and their quality assurance practices. The objective of this document is to present to those who intend to launch a kit preparation programme a set of preparation procedures and other relevant information gathered during kit production over a period of more than a decade, to serve as a good starting point. The manuals and monographs included in the document are based on the experience gained in two major centres. The publication of this material is intended to give a typical example, and not the only possible procedure for preparing the kits. Following the essentials of these kit preparation procedures, it is always possible to make alterations to the composition of the kits. The kits described here concern widely used 99 Tc m radiopharmaceuticals which do not require a Single Photon Emission Computed Tomography (SPECT) camera. These examples of the ''first generation'' of kits are not very intricate to prepare. Although it is advisable to have only one agent for a given intended use, a few agents for each purpose, e.g. EHDP and MDP for bone imagining, have been included in the document so that the reader can have some flexibility in selecting a particular kit. 24 refs, 2 figs

  15. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  16. 21 CFR 868.5140 - Anesthesia conduction kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  17. 21 CFR 864.2260 - Chromosome culture kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chromosome culture kit. 864.2260 Section 864.2260...) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Cell And Tissue Culture Products § 864.2260 Chromosome culture kit. (a) Identification. A chromosome culture kit is a device containing the necessary ingredients...

  18. The challenges of lean manufacturing implementation in kitting assembly

    Science.gov (United States)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  19. Verification and accreditation schemes for climate change activities: A review of requirements for verification of greenhouse gas reductions and accreditation of verifiers—Implications for long-term carbon sequestration

    Science.gov (United States)

    Roed-Larsen, Trygve; Flach, Todd

    The purpose of this chapter is to provide a review of existing national and international requirements for verification of greenhouse gas reductions and associated accreditation of independent verifiers. The credibility of results claimed to reduce or remove anthropogenic emissions of greenhouse gases (GHG) is of utmost importance for the success of emerging schemes to reduce such emissions. Requirements include transparency, accuracy, consistency, and completeness of the GHG data. The many independent verification processes that have developed recently now make up a quite elaborate tool kit for best practices. The UN Framework Convention for Climate Change and the Kyoto Protocol specifications for project mechanisms initiated this work, but other national and international actors also work intensely with these issues. One initiative gaining wide application is that taken by the World Business Council for Sustainable Development with the World Resources Institute to develop a "GHG Protocol" to assist companies in arranging for auditable monitoring and reporting processes of their GHG activities. A set of new international standards developed by the International Organization for Standardization (ISO) provides specifications for the quantification, monitoring, and reporting of company entity and project-based activities. The ISO is also developing specifications for recognizing independent GHG verifiers. This chapter covers this background with intent of providing a common understanding of all efforts undertaken in different parts of the world to secure the reliability of GHG emission reduction and removal activities. These verification schemes may provide valuable input to current efforts of securing a comprehensive, trustworthy, and robust framework for verification activities of CO2 capture, transport, and storage.

  20. 46 CFR 169.725 - First aid kit.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  1. 46 CFR 108.707 - First aid kit.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  2. Core Flight System Satellite Starter Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — The Core Flight System Satellite Starter Kit (cFS Kit) will allow a small satellite or CubeSat developer to rapidly develop, deploy, test, and operate flight...

  3. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    Science.gov (United States)

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  4. {sup 14}C urea breath test kit- an evaluation of a compact, cost-effective kit for the detection of H. pylori

    Energy Technology Data Exchange (ETDEWEB)

    Bellon, M.S. [Royal Adelaide Hospital, SA (Australia). Dept of Nuclear Medicine

    1998-03-01

    Full text: Helicobacter pylori infection of the gastric mucosa causes active chronic gastritis and peptic ulceration. Carbon-14 urea breath testing has been well documented in its ability to detect the presence of H. pylori. The aims of this study were to evaluate and refine the test to substantially reduce costs and improve its simplicity, availability and accuracy. We reviewed the results of 138 patients who underwent {sup 14}C urea breath testing for the detection of H. pylori utilising a kit developed at the Royal Adelaide Hospital. Modifications to the standard technique that were assessed included the relevance of buccal cleansing, single sample v multiple sampling, use of alternative CO{sub 2} absorbers and sampling techniques. In those patients with positive biopsy results, a test sensitivity of 100% was achieved. No buccal cleansing is necessary (45% oral contamination without brushing teeth v 41% with). A single breath sample only at 15 min resulted in 100% sensitivity. Alternative (cheaper and safer) CO{sub 2} absorbers such as KOH can be used. Based on these results, modifications to this well documented test have enabled us to substantially reduce costs, improve simplicity and safety and increase accuracy and availability of the test for the detection of Helicobacter pylori.

  5. Kit with track detectors aiming at didactic

    International Nuclear Information System (INIS)

    Cesar, M.F.; Koskinas, M.F.

    1988-01-01

    The kit intends to improve the possibilities in performing experiments of Nuclear Physics in Modern Physics Laboratories of Physics Course introducing the solid state nuclear track detectors. In these materials the passage of heavily ionizing nuclear particles creates paths (tracks) that may be revealed and made visible in an optical microscope. By the help of the kit several experiments and/or demonstrations may be performed. The kit contains solid state nuclear track detectors unirradiated and irradiated, irradiated etched and uneteched sheets; an alpha source of 241 Am and an instrution text with photomicrographs. To use the kit the laboratory must have an ordinary optical microscope. (author) [pt

  6. Iodine-125--digoxin radioimmunoassay: comparison of commercial kits

    International Nuclear Information System (INIS)

    Battaglia, D.J.; Cianci, M.L.

    1976-01-01

    Iodine-125-digoxin radioimmunoassay kits available from Abbott Diagnostics (AD), Dade Division (D), Schwarz/Mann (SM), and Clinical Assays (CA) were evaluated with respect to assay quality. The kit accuracies did not differ significantly at 2.0 ng/ml and the interassay coefficients of variation ranged from 9 percent (AD) to 21.4 percent (CA). The accuracy for all kits above 4 ng/ml is questionable, and since serum-dilution values correlated well with undiluted serum values, the dilution method of dose quantitation is preferable for levels above 4 ng/ml. Although all the kits were adequate for evaluating digoxin at the 2 ng/ml level, the Abbott kit seems to be of slightly better quality

  7. Preparation of albumin radioimmunoassay kit

    International Nuclear Information System (INIS)

    Chen Suoshu; Wang Yanzhen; Wang Zhenshan

    1990-01-01

    This paper presents the preparation of Albumin (Alb) radioimmunoassay kit and its preliminary clinical application. The kit is mainly applied to the measurement of Alb concentration in human urine, adopting second antibody-PEG method. The measurement range is (1-50 μg/ml). The curve obtained with a serially diluted urine sample of high Alb concentration was a straight line. Recovery, detectability, intra- and inter-batch variation coefficients were 95.7%-103.6%, 0.1 μg/ml, 5.8% and 6.4% respectively. The kit was tried out clinically for measuring Alb in urine samples in about 1200 normal individuals and 600 various patients of related renal diseases. The preliminary clinical results show that Alb RIA is conducive to the early diagnosis of kidney function abnormalities

  8. Environmental Technology Verification Report for Abraxis Ecologenia® Ethynylestradiol (EE2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis Ecologenia Ethynylestradiol (EE2) ...

  9. Development of Safety Kit for Industrial Radiography Application

    International Nuclear Information System (INIS)

    Mohd Noorul Ikhsan Ahmad; Amry Amin Abas

    2011-01-01

    A safety kit for industrial radiography has been developed. The safety kit that consist of a set of technical rod and various size of base that can be used in radiograph of pipe with diameter between half and one and half inch with utilization of collimator. With the kit, radiographers will not having anymore problem to use collimator in their work. The paper discuss about the technical measures of the safety kit and the importance of introducing it to the industry. (author)

  10. Trükitööstuste TOP 50

    Index Scriptorium Estoniae

    2002-01-01

    Trükitööstuste TOP 50. Käibe TOP 30. Käibe kasum TOP 30. Kasvu TOP 30. Kasumi kasvu TOP 30. Rentaabluse TOP. Varade tootlikkuse TOP. Trükitööstusettevõtete üldandmed. Trükitööstusettevõtete finantsandmed

  11. C-kit-targeted imaging of gastrointestinal stromal tumor using radiolabeled anti-c-kit monoclonal antibody in a mouse tumor model

    International Nuclear Information System (INIS)

    Sogawa, Chizuru; Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Yoshida, Chisato; Odaka, Kenichi; Uehara, Tomoya; Arano, Yasushi; Koizumi, Mitsuru; Saga, Tsuneo

    2010-01-01

    Introduction: Gastrointestinal stromal tumor (GIST) is the most common mesenchymal tumor arising from the gastrointestinal tract and highly expresses mutated c-kit. We aimed to develop a specific and sensitive method for detecting GISTs using radiolabeled anti-c-kit monoclonal antibody. Methods: A mutated c-kit-expressing cell clone was established by transfecting an expressing vector of mutated c-kit gene into HEK293 human embryonic kidney cells. The tumors were developed by inoculating c-kit-expressing cells into nude mice. 125 I- and 111 In-labeled anti-c-kit antibodies (12A8 and 41A11) were evaluated in vitro by cell binding, competitive inhibition and cellular internalization assays, and in vivo by biodistribution and imaging studies in tumor-bearing mice. Results: Both 125 I- and 111 In-labeled antibodies showed specific binding with c-kit-expressing cells with high affinity (dissociation constants = 2.2-7.1x10 9 M -1 ). Internalization assay showed that 125 I-labeled antibodies were rapidly internalized and dehalogenated, with the release of 125 I from the cells, resulting in reduction of cell-associated radioactivity with time. In contrast, 111 In-labeled antibody was internalized but did not result in the reduced radioactivity associated with tumor cells. Reflecting this phenomenon, the in vivo tumor uptake of 125 I-labeled antibody was low on Day 1, further decreasing with time, while tumor uptake of 111 In-labeled antibody was high on Day 1, further increasing with time. The xenografted tumor was clearly visualized by scintigraphy after injection of 111 In-labeled antibody. Conclusion: The anti-c-kit monoclonal antibody labeled with a metal radionuclide would be promising for c-kit-targeted imaging of GISTs.

  12. Discovery of amido-benzisoxazoles as potent c-Kit inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Roxanne K.; Rumfelt, Shannon; Chen, Ning; Zhang, Dawei; Tasker, Andrew S.; Bürli, Roland; Hungate, Randall; Yu, Violeta; Nguyen, Yen; Whittington, Douglas A.; Meagher, Kristin L.; Plant, Matthew; Tudor, Yanyan; Schrag, Michael; Xu, Yang; Ng, Gordon Y.; Hu, Essa (Amgen)

    2010-01-12

    Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.

  13. Development of positron emission tomography probe of 64Cu-labeled anti-C-kit 12A8 Fab to measure protooncogene C-kit expression

    International Nuclear Information System (INIS)

    Yoshida, Chisato; Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Sogawa, Chizuru; Inubushi, Masayuki; Uehara, Tomoya; Fukumura, Toshimitsu; Koizumi, Mitsuru; Arano, Yasushi; Saga, Tsuneo

    2011-01-01

    Introduction: C-kit is an important diagnostic and therapeutic target molecule for several malignancies, and c-kit-targeted drugs have been used clinically. Because abundant c-kit expression in tumors is a prerequisite for successful c-kit-targeted therapy, imaging of c-kit expression is expected to play a pivotal role in the therapeutic decision for each patient. We evaluated 64 Cu-labeled Fab of anti-c-kit antibody 12A8 as a positron emission tomography (PET) imaging probe. Methods: 111 In- or 125 I-Labeled 12A8 Fab was evaluated in vitro by cell binding, competitive inhibition and cellular internalization assays, and in vivo by biodistribution in mice bearing c-kit-expressing and -non-expressing tumors. Next, Fab fragment was labeled with the positron emitter 64 Cu and evaluated by PET. Results: Radiolabeled 12A8 Fab showed specific binding to c-kit-expressing cells with high affinity and internalized into cells after binding to c-kit on cell surface. Although tumor accumulation of [ 111 In]Fab was lower than that of [ 111 In]IgG, the faster blood clearance of [ 111 In]Fab provided higher tumor-to-blood ratio at 6 h postinjection onwards. Blood clearance of 64 Cu-labeled 12A8 Fab was slower than that of [ 111 In]Fab, but PET using [ 64 Cu]Fab clearly visualized the tumor at 6 h postinjection onwards. Conclusion: The 64 Cu-labeled 12A8 Fab could be used for c-kit-specific PET imaging and might help in selecting appropriate patients for c-kit-targeted treatments.

  14. Personal Computer-less (PC-less) Microcontroller Training Kit

    Science.gov (United States)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  15. Escherichia coli and virus isolated from ''sticky kits''

    DEFF Research Database (Denmark)

    Jørgensen, M.; Scheutz, F.; Strandbygaard, Bertel

    1996-01-01

    A total of 121 Escherichia coli strains isolated from 3-week-old mink kits were serotyped and examined for virulence factors. 56 strains were isolated from healthy kits while 65 were from ''sticky kits''. Among these, 34 different serotypes were detected. No difference in serotypes or the presenc...

  16. C-kit expression in canine mucosal melanomas.

    Science.gov (United States)

    Newman, S J; Jankovsky, J M; Rohrbach, B W; LeBlanc, A K

    2012-09-01

    The c-kit receptor is responsible for transmission of promigration signals to melanocytes; its downregulation may be involved in malignant progression of human melanocytic neoplasms. Expression of this receptor has not been examined in normal or neoplastic melanocytes from dogs. In this study, 14 benign dermal and 61 malignant mucosal melanocytic tumors were examined for c-kit (KIT) expression. Sites of the mucosal melanomas were gingiva (not further specified; n = 30), buccal gingiva (n = 6), soft palate (n = 4), hard palate (n = 5), tongue (n = 7), lip (n = 6), and conjunctiva (n = 3). Melan A was expressed in all 14 dermal melanocytomas and in 59 of 61 (96.7%) tumors from oral or conjunctival mucosa, confirming melanocytic origin. C-kit receptor expression was strong and diffuse throughout the cytoplasm in all 14 dermal melanocytomas and was identified in basilar mucosal melanocytes over submucosal neoplasms (27 of 61, 44.3%), junctional (neoplastic) melanocytes (17 of 61, 27.9%), and, less commonly, neoplastic melanocytes of the subepithelial tumors (6 of 61, 9.8%). KIT expression anywhere within the resected melanomas correlated with significantly longer survival. These results suggest that c-kit receptor expression may be altered in canine melanomas and may have potential as a prognostic indicator for mucosal melanomas.

  17. Multicentre evaluation of commercial kit methods

    DEFF Research Database (Denmark)

    Gram, J; Declerck, P J; Sidelmann, Johannes Jakobsen

    1993-01-01

    In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved in...... of the plasma samples, which was PAI-1 depleted. The laboratories involved in the testing reported for this sample a mean value of 6.1 IU/ml.(ABSTRACT TRUNCATED AT 250 WORDS)......In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved...... in the production of data from each of the commercial kits tested. A considerable variation of PAI activity results reported from the laboratories testing the same commercial kits was observed. The range of reported results could in individual samples exceed the median value indicating an interlaboratory variation...

  18. c-Kit signaling determines neointimal hyperplasia in arteriovenous fistulae

    Science.gov (United States)

    Skartsis, Nikolaos; Martinez, Laisel; Duque, Juan Camilo; Tabbara, Marwan; Velazquez, Omaida C.; Asif, Arif; Andreopoulos, Fotios; Salman, Loay H.

    2014-01-01

    Stenosis of arteriovenous (A-V) fistulae secondary to neointimal hyperplasia (NIH) compromises dialysis delivery, which worsens patients' quality of life and increases medical costs associated with the maintenance of vascular accesses. In the present study, we evaluated the role of the receptor tyrosine kinase c-Kit in A-V fistula neointima formation. Initially, c-Kit was found in the neointima and adventitia of human brachiobasilic fistulae, whereas it was barely detectable in control veins harvested at the time of access creation. Using the rat A-V fistula model to study venous vascular remodeling, we analyzed the spatial and temporal pattern of c-Kit expression in the fistula wall. Interestingly, c-Kit immunoreactivity increased with time after anastomosis, which concurred with the accumulation of cells in the venous intima. In addition, c-Kit expression in A-V fistulae was positively altered by chronic kidney failure conditions. Both blockade of c-Kit with imatinib mesylate (Gleevec) and inhibition of stem cell factor production with a specific short hairpin RNA prevented NIH in the outflow vein of experimental fistulae. In agreement with these data, impaired c-Kit activity compromised the development of NIH in A-V fistulae created in c-KitW/Wv mutant mice. These results suggest that targeting of the c-Kit signaling pathway may be an effective approach to prevent postoperative NIH in A-V fistulae. PMID:25186298

  19. Energy Management Curriculum Starter Kit

    Energy Technology Data Exchange (ETDEWEB)

    Turner, W.C.

    1987-02-01

    The Energy Management Curriculum Starter Kit was designed to help engineering educators develop and teach energy management courses. Montana State University and Oklahoma State University courses are embodied in the model curriculum given. The curricula offered at many other universities throughout the United States are also presented. The kit was designed specifically to train engineering students to be good energy managers. Courses at both the undergraduate and postgraduate level are presented.

  20. Modifications at operating nuclear power plants

    International Nuclear Information System (INIS)

    Duffy, T.J.; Gazda, P.A.

    1985-01-01

    Modifications at operating nuclear power plants offer the structural engineer many challenges in the areas of scheduling of work, field adjustments, and engineering staff planning. The scheduling of structural modification work for operating nuclear power plants is normally closely tied to planned or unplanned outages of the plant. Coordination between the structural engineering effort, the operating plant staff, and the contractor who will be performing the modifications is essential to ensure that all work can be completed within the allotted time. Due to the inaccessibility of some areas in operating nuclear power plants or the short time available to perform the structural engineering in the case of an unscheduled outrage, field verification of a design is not always possible prior to initiating the construction of the modification. This requires the structural engineer to work closely with the contractor to promptly resolve problems due to unanticipated interferences or material procurement problems that may arise during the course of construction. The engineering staff planning for structural modifications at an operating nuclear power plant must be flexible enough to permit rapid response to the common ''fire drills,'' but controlled enough to ensure technically correct designs and to minimize the expenditure of man-hours and the resulting engineering cost

  1. CERN’s FMC Kit

    CERN Document Server

    Cattin, M; Serrano, J; van der Bij, E; Wlostowski, T

    2014-01-01

    In the context of the renovation of controls and data acquisition electronics for accelerators the BE-CO-HT section at CERN has designed a kit based on carriers and mezzanines following the VITA FPGAMezzanine Card (FMC) standard. Carriers exist in VME64x and PCIe form factors, with a PXIe carrier underway. Mezzanines include an Analog to Digital Converter, a Time to Digital Converter, a fine delay generator and a Digital Input/Output. All of the designs are licensed under the CERN Open Hardware Licence and commercialised by companies. This paper discusses the benefits of this carrier mezzanine strategy and of the Open Hardware based commercial paradigm. It also explains the design of each layer of the FMC kit, from the hardware to the gateware and the Linux device driver. In addition, several tools to help designers developing gateware for mezzanines and new concepts such as the Self-Describing Bus (SDB) and the fmcbus are presented. Lastly, some of the plans for the future of the FMC kit and Open Hardware Re...

  2. The Fluid Dynamics Demo Kit: Part I

    Science.gov (United States)

    Flack, Karen; Underhill, Patrick; Prestridge, Kathy

    2012-11-01

    The goal of this project is to develop a fluid dynamics demonstration/experiment kit that can be used by professors and graduate students at high school outreach events. The demonstrations in the kit will be easy to use and true crowd pleasers in order to inspire understanding and pique curiosity about the physics of flow. The kits will be inexpensive, containing readily available materials so that teachers can duplicate the demonstrations and experiments. The kits will be left with the teachers as a gift from the American Physics Society. The experiments and demonstrations cover the concepts of conservation of mass, momentum, and energy, Bernoulli's equation, frictional losses and the ideal gas law. For each experiment, the teachers will receive presentation material, access to instructional videos, plus a worksheet that can be used in a high school physics classroom. This kit has been developed through the efforts of the APS-DFD Mentoring and Outreach Committee and has received funding from the APS-DFD. Work funded by the APS-DFD.

  3. Comparative studies of commercially available T4-RIA-kits. Pt. 2

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Lipke, P.

    1978-01-01

    The investigation of the tested commercially available T 4 -RIA-Kits have shown that: The separation of hypo-, eu- and hyperthyroid values is better with kits a) and f) than with b), c), d) and e), though all kits give acceptable values under routine operating conditions, kit b) takes less time and work than the other tested kits, depending on the kit used, the time needed for 100 determinations varies between 1,5 and 4 hr. A general recommendation for one of the tested T 4 -RIA-Kits cannot be made since the choice of a kit depends not only on the criteria discussed but also on local circumstances. (orig.) [de

  4. Estradiol RIA kit in clinical practice

    International Nuclear Information System (INIS)

    Friedrich, W.; Lisse, K.; Bienert, R.; Flentje, H.; Koerner, H.; Wilken, T.; Akademie der Wissenschaften der DDR, Berlin-Buch. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1985-01-01

    First clinical experience with a estradiol RIA kit developed in the Central Institute for Isotope- and Radiation Research is reported. The kit was used for the daily control of estradiol level in patients, which were treated within the program for in vitro fertilization and embryo transfer. The time of incubation could be shortened by means of a double antibody technique and by use of a precipitation mixture to 2 h. The intraassay variation is 9.2%, the interassay variation is 15.1%, the recovery rate is 94%. The sensitivity of the test (B 0 -3SD) is about 120 pmol/l. The estradiol RIA kit satisfies clinical requirements. (author)

  5. A fiber-optic polarimetric demonstration kit

    International Nuclear Information System (INIS)

    Eftimov, T; Dimitrova, T L; Ivanov, G

    2012-01-01

    A simple and multifunctional fiber-optic polarimetric kit on the basis of highly birefringent single-mode fibers is presented. The fiber-optic polarimetric kit allows us to perform the following laboratory exercises: (i) fiber excitation and the measurement of numerical aperture, (ii) polarization preservation and (iii) obtain polarization-sensitive fiberized interferometers.

  6. 33 CFR 144.01-30 - First-aid kit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  7. Distribution and ultrastructure of interstitial cells of Cajal in the mouse colon, using antibodies to Kit and Kit(W-lacZ) mice

    DEFF Research Database (Denmark)

    Vanderwinden, J M; Rumessen, J J; Bernex, F

    2000-01-01

    kinase receptor Kit as a marker. Sections and whole mounts were studied by confocal microscopy after double immunofluorescence with specific antibodies. The ultrastructure of Kit-expressing cells was examined by electron microcopy in KitW-lacz/+ transgenic mice, which carry the lacz gene inserted...

  8. Production of sestamibi kit for nuclear imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Hakim; Zakaria, Ahmad; Yaacob, Hadzri; Ramli, Jamaluddin [Universiti Sains Malaysia, Kelantan (Malaysia). School of Medical Sciences

    1997-12-01

    One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci per 20 gm body weight. The mice were sacrificed at 3 hours and 24 hours after the dose administration. Blood, heart, lung, intestine, kidney and stomach samples were obtained, weighed and measured for radioactivity using gamma well counter. The data showed that after 3 hours about 60% of the injected dose accumulated in the intestine which was in agreement with IAEA standard. At 24 hours the amount in the heart still remained about 25% of the 3 hour uptake. In house production of MIBI kit is easy, fast and cost effective. The data suggested that the quality of our kit was good enough to be used for further animal research and clinical trials.

  9. c-Kit expression in somatosensory nuclei of lower medulla oblongata.

    Science.gov (United States)

    Pop, Elena; Mărdărescu, Mariana; Lazăr, M; Rusu, M C; Ion, Daniela Adriana

    2013-01-01

    Protein kinase signal-transduction pathways play critical roles in regulating nociception. The c-kit receptor contributes to pain regulation in the spinal cord and is present on both peripheral and central terminals. Expression of c-kit was demonstrated in human trigeminal and spinal ganglia. However, the brainstem expression of c-kit was overlooked. We aimed to evaluate it by immunohistochemistry, on eight samples of human lower medulla oblongata. We used two clones of CD117/c-kit antibodies, from different manufacturers, and neurofilament antibodies. Positive expression of CD117/c-kit was found within the spinal trigeminal nucleus, the gracilis, cuneate, and lateral cuneate nuclei, and within the olivary complex. CD117/c-kit positive interstitial networks of these nuclei were positively labeled with neurofilaments. CD117/c-kit labeled the olivary neurons, but not the magnocellular neurons of the trigeminal, gracilis and cuneate nuclei. c-kit interstitial systems of brainstem could play so an important role for the functional status along the somatosensory neural circuits.

  10. A comparative study in three commercial kits of radioligand assay for GAD-Ab

    International Nuclear Information System (INIS)

    Yang Yehua; Zhou Zhiguang; Huang Gan; Yang Feike; Li Zhangwei

    2006-01-01

    Objective: To provide data for perfect selection of glutamic acid decarboxylase antibodies (GAD-Ab) assay commercial kits. Methods: The sera of 88 titer-graded samples by radioligand assay (RLA) were measured with two types of enzyme-linked immunosorbent assay (ELISA) kits and one type of immunoradiometric assay (IRMA) kit for GAD-Ab in order to test their consistency with RLA. Another 140 diabetic sera were measured with RLA and screened by a type of suitable kit to search the cutoff point for discriminating patients who needed rechecking. Results: Compared with RLA, concordance ratio of 3 kits: Medizym kit(75%) > RSR kit(73.9%) > Biomerica kit(62.5%); Kappa value: Medizym kit (0.408, common) > RSR kit (0.405, common) > Biomerica kit (0.185, failing); correlation to RLA index: RSR kit (r= 0.992) > Medizym kit(r= 0. 791 ) > Biomerica kit (r = -0. 055); area under the receiver operating characteristic (ROC) curve: Medizym kit (0.812) > RSR kit (0. 727 ) > Biomerica kit (0.666). Conclusions: The efficiencies of RSR kit and Medizym kit are good. Serum concentration between 0.25-0.99 U/ml measured by RSR kit is suggested to further recheck by RLA. (authors)

  11. Basic and clinical evaluation of CA 130 RIA kit (D-7111) using two newly developed monoclonal antibodies. Comparison with CA 125 kit

    Energy Technology Data Exchange (ETDEWEB)

    Saga, Tsuneo; Endo, Keigo; Nakajima, Tetsuo and others

    1988-10-01

    The CA 130 RIA kit was developed with the use of two monoclonal antibodies, 130 - 22 and 145 - 9. Laboratory performance was satisfactory for precision, reproducibility, recovery, and dilution. Measurement values with CA 130 kit were almost consistent with those with CA 125 kit. Favorable standard curves were attained with smaller concentrations and shorter incubation time of CA 130 kit than those with CA 125 kit. There was less prozone phenomenon. When defining a cut-off serum level of CA 130 as 35 U/ml, false-positive rate was 0 % for healthy men and 4 % for healthy women, suggesting the involvement of menstrual cycle. Positive rate for CA 130 was 65 % for malignant ovarian tumor, 48 % for lung cancer, and 47 % for endometriosis. (Namekawa, K.).

  12. Chemistry of /sup 99m/Tc labeling kits

    International Nuclear Information System (INIS)

    Srivastava, S.C.; Meinken, G.; Richards, P.

    1976-01-01

    Problems have been reported with the use of kit-produced /sup 99m/Tc radiopharmaceuticals. This study was undertaken to understand the chemistry involved in various stannous kit systems. The relation between Tc, tin, and the ligands used to complex the reduced Tc was investigated. It is concluded that for reliable performance, stannous kits should be prepared so that most of the tin is kept in the usable (reducing) form; a solution would be to use minimum tin and a large excess of complexing agent. Oxidation of the Tc complex to free pertechnetate is not a major problem in most kit systems. 5 figures

  13. Building Use Policies. SPEC Kit 144.

    Science.gov (United States)

    Coyle, Patrick

    This Systems and Procedures Exchange Center (SPEC) flyer/kit addresses some of the needs of Association of Research Libraries (ARL) members regarding library building use and the aesthetics and well-being of the materials and people in the building. The kit draws upon documents gathered as part of a 1986 Quick-SPEC survey that dealt with food and…

  14. Statistical modeling of dental unit water bacterial test kit performance.

    Science.gov (United States)

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  15. Utilization of milk energy by suckling mink kits

    DEFF Research Database (Denmark)

    Tauson, Anne-Helene; Fink, Rikke; Hansen, Kirsten Bislev

    2004-01-01

    A total of 36 mink dams and their litters of 3, 6 or 9 kits were used for determination of milk intake of the suckling young by means of deuterium dilution technique, and chemical composition of milk and of kit bodies. Measurements were performed during lactation weeks 1-4, each week with 3 dams...... with each litter size. Milk intake was determined over a 48 h measurement period, and by the end of this milk samples were collected and 2 kits (litters of 6 and 9) or 1 kit per litter (litters of 3) were killed for body chemical composition. Based on the results, different models were applied...... for calculation of the energetic efficiency of milk. Dam milk yield increased steadily from week 1 until week 3 but only slightly from week 3 to 4. The increase declined with increasing litter size, and for dams suckling 9 kits the increment from week 3 to week 4 was only 2 g. The dry matter content of milk...

  16. KiT: a MATLAB package for kinetochore tracking.

    Science.gov (United States)

    Armond, Jonathan W; Vladimirou, Elina; McAinsh, Andrew D; Burroughs, Nigel J

    2016-06-15

    During mitosis, chromosomes are attached to the mitotic spindle via large protein complexes called kinetochores. The motion of kinetochores throughout mitosis is intricate and automated quantitative tracking of their motion has already revealed many surprising facets of their behaviour. Here, we present 'KiT' (Kinetochore Tracking)-an easy-to-use, open-source software package for tracking kinetochores from live-cell fluorescent movies. KiT supports 2D, 3D and multi-colour movies, quantification of fluorescence, integrated deconvolution, parallel execution and multiple algorithms for particle localization. KiT is free, open-source software implemented in MATLAB and runs on all MATLAB supported platforms. KiT can be downloaded as a package from http://www.mechanochemistry.org/mcainsh/software.php The source repository is available at https://bitbucket.org/jarmond/kit and under continuing development. Supplementary data are available at Bioinformatics online. jonathan.armond@warwick.ac.uk. © The Author 2016. Published by Oxford University Press.

  17. Environmental Technology Verification Report for Abraxis 17β-Estradiol (E2) Magnetic Particle Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis 17(beta)-estradiol (E2) magnetic p...

  18. Usefulness of CA 130 kit based on IRMA

    International Nuclear Information System (INIS)

    Fujii, Takashi; Kimura, Yoshiko; Ata, Mariko; Miyagawa, Naoko; Iio, Atsushi; Hamamoto, Ken

    1988-01-01

    Immunoradiometric assay for CA 130 was fundamentally and clinically evaluated using a commercially available D-7111 kit. Incubation time was 4 hr with the present CA 133 kit as compared with 16 - 24 hr with conventional CA 125 kit. Laboratory performance of CA 130 kit was satisfactory for standard curve, reproducibility, and recovery test. There was well correlation between the present CA 130 kit and CA 125 kit (r = 0.931). The concentration of CA 130 in the serum was significantly higher in healthy women than men (17.3 +- 10.5 U/ml vs 9.6 +- 5.1 U/ml). Serum CA 130 levels tended to decrease with aging, regardless of sex. These levels were changeable with menstrual cycle ; i.e., these were significantly higher during menstrual phase (24.2 +- 9.0 U/ml) and significantly lower during ovulatory phase (10.9 +- 2.4 U/ml) and during menopause (12.1 +- 3.4 U/ml). Cut off serum CA 130 levels were defined as 20 U/ml for men and 38 U/ml for women. Positive rate for CA 130 was the highest in cases of ovarian cancer (80 %), followed by endometrial cancer (50 %), pancreatic cancer (47 %), benign ovarian tumor (44 %), and lung cancer (39 %). (Namekawa, K.)

  19. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  20. [The comparison of two newborn cytomegalovirus IgG antibody screening ELISA kits].

    Science.gov (United States)

    Zhang, Shun-Xian; He, Xiao-Zhou; Wang, Shi-Wen; Wang, Xiao-Fang

    2013-10-01

    This study compared two newborn Cytomegalovirus (CMV) IgG antibody screening ELISA kits and evaluated the detection effectiveness of Abnova kit. CMV IgG antibodies were detected by both SeraQuest and Abnova kits from dried blood spot (DBS) samples of 488 newborn heel sticks. The detection abilities of these two kits were compared in different sample dilution concentrations. Relative detection effectiveness of the Abnova kit was defined by statistical method using the SeraQuest kit as a point of comparison. Compared to the SeraQuest screening test kit, the Abnova kit revealed a sensitivity of 98.9%, specificity of 78.6%, positive predictive value of 99.3%, negative predictive value of 68.8%, and the coincidence rate for these two screening test kits at 98.3%. The consistency check of both kits based on interpretation of the kappa statistic was relatively good. For the Abnova kit, the "area under the ROC curve" was 0.887, which indicates moderate accuracy. Abnova kit can be applied to newborn screening for congenital CMV infections. However, repeating the test for ambiguous results is suggested to increase the specificity and negative predictive value.

  1. Engineerig of structural modifications for operating nuclear plants

    International Nuclear Information System (INIS)

    Duffy, T.J.; Gazda, P.A.

    1983-01-01

    The engineering of structural modifications for operating nuclear plants offers many challenges in the areas of scheduling of work, field adjustments, and engineering staff planning. The scheduling of structural modification work for operating nuclear plants is normally closely tied to planned or unplanned outages of the plant. Coordination between the structural engineering effort, the operating plant staff, and the contractor who will be performing the modifications is essential to ensure that all work can be completed within the allotted time. Due to the inaccessibility of areas in operating plants or the short time available to perform the structural engineering in the case of an unscheduled outage, field verification of a design is not always possible prior to initiating the construction of the modification. This requires the structural engineer to work closely with the contractor to promptly resolve problems due to unanticipated interferences or material procurement that may arise during the course of construction. The engineering staff planning for structural modifications at an operating nuclear plant must be flexible enough to permit rapid response to the common 'fire drills', but controlled enough to assure technically correct designs and minimize the expenditure of man-hours and resulting engineering cost. (orig.)

  2. The Winfrith lecturers' demonstration kits for radiation and radioactivity

    International Nuclear Information System (INIS)

    Woffinden, G.B.

    1981-01-01

    During the early part of the 1970s a need arose for suitable aids to assist lecturers in giving talks on radioactivity and radiation to employees and occasionally to science students in local schools and colleges. A kit capable of demonstrating the basic properties of alpha, beta and gamma radiation was assembled for these purposes. During the latter half of the decade a demand arose for talks to non-scientific groups of the general public on nuclear power and radiation and some of the items in the original demonstration kit were found to be appropriate for these talks. The items used, now constitute the Basic Demonstration Kit. Meanwhile, a few changes or additions were made to the original kit which is now known as the Comprehensive Demonstration Kit. (author)

  3. Association of KIT exon 9 mutations with nongastric primary site and aggressive behavior: KIT mutation analysis and clinical correlates of 120 gastrointestinal stromal tumors.

    Science.gov (United States)

    Antonescu, Cristina R; Sommer, Gunhild; Sarran, Lisa; Tschernyavsky, Sylvia J; Riedel, Elyn; Woodruff, James M; Robson, Mark; Maki, Robert; Brennan, Murray F; Ladanyi, Marc; DeMatteo, Ronald P; Besmer, Peter

    2003-08-15

    Activating mutations of the KIT juxtamembrane region are the most common genetic events in gastrointestinal stromal tumors (GISTs) and have been noted as independent prognostic factors. The impact of KIT mutation in other regions, such as the extracellular or kinase domains, is not well-defined and fewer than 30 cases have been published to date. One hundred twenty GISTs, confirmed by KIT immunoreactivity, were evaluated for the presence of KIT exon 9, 11, 13, and 17 mutations. The relation between the presence/type of KIT mutation and clinicopathological factors was analyzed using Fisher's exact test and log-rank test. Forty-four % of the tumors were located in the stomach, 47% in the small bowel, 6% in the rectum, and 3% in the retroperitoneum. Overall, KIT mutations were detected in 78% of patients as follows: 67% in exon 11, 11% in exon 9, and none in exon 13 or 17. The types of KIT exon 11 mutations were heterogeneous and clustered in the classic "hot spot" at the 5' end of exon 11. Seven % of cases showed internal tandem duplications (ITD) at the 3' end of exon 11, in a region that we designate as a second hot spot for KIT mutations. Interestingly, these cases were associated with: female predominance, stomach location, occurrence in older patients, and favorable outcome. There were significant associations between exon 9 mutations and large tumor size (P < 0.001) and extragastric location (P = 0.02). Ten of these 13 patients with more than 1-year follow-up have developed recurrent disease. Most KIT-expressing GISTs show KIT mutations that are preferentially located within the classic hot spot of exon 11. In addition, we found an association between a second hot spot at the 3'end of exon 11, characterized by ITDs, and a subgroup of clinically indolent gastric GISTs in older females. KIT exon 9 mutations seem to define a distinct subset of GISTs, located predominantly in the small bowel and associated with an unfavorable clinical course.

  4. Advanced verification topics

    CERN Document Server

    Bhattacharya, Bishnupriya; Hall, Gary; Heaton, Nick; Kashai, Yaron; Khan Neyaz; Kirshenbaum, Zeev; Shneydor, Efrat

    2011-01-01

    The Accellera Universal Verification Methodology (UVM) standard is architected to scale, but verification is growing and in more than just the digital design dimension. It is growing in the SoC dimension to include low-power and mixed-signal and the system integration dimension to include multi-language support and acceleration. These items and others all contribute to the quality of the SOC so the Metric-Driven Verification (MDV) methodology is needed to unify it all into a coherent verification plan. This book is for verification engineers and managers familiar with the UVM and the benefits it brings to digital verification but who also need to tackle specialized tasks. It is also written for the SoC project manager that is tasked with building an efficient worldwide team. While the task continues to become more complex, Advanced Verification Topics describes methodologies outside of the Accellera UVM standard, but that build on it, to provide a way for SoC teams to stay productive and profitable.

  5. Experience with Phadebas hCS (HPL)-Test kit

    International Nuclear Information System (INIS)

    Herter, U.

    1976-01-01

    The RIA determination of human placental lactogen (HPL) is described using the Phadebas test kit by Pharmacia, Sweden. The results of the test are shown graphically. The kit was tested over a period of one year and the tests were modified to meet the requirements of clinical examinations. The calibration curve is constant and applicable for a period of 14 days. The Phadebas kit has proved to be advantageous for both scientific research work and for routine clinical examinations. (L.O.)

  6. FitMindKit: Randomised controlled trial of an automatically tailored online program for mood, anxiety, substance use and suicidality

    Directory of Open Access Journals (Sweden)

    Philip J. Batterham

    2018-06-01

    Full Text Available Purpose: Online mental health programs can be effective in reducing symptoms of depression, anxiety disorders, substance use and suicidal ideation. However, most existing e-mental health programs focus on a single domain of mental health, neglecting comorbidity. Furthermore, few programs are tailored to the symptom patterns of the individual user. FitMindKit was designed to overcome the gaps of existing e-mental health programs, providing tailored, transdiagnostic therapeutic content to address a range of comorbid mental health symptoms. A trial was conducted to test the program's efficacy. Methods: Australian adults with elevated symptoms of depression, anxiety, suicidal ideation and/or substance use were recruited through social media, with n=194 randomised into a fully-automated trial of a 10-day brief intervention. Participants were randomly allocated to receive FitMindKit tailored to their symptoms, an untailored generic version of FitMindKit, or an attention control. Results: Mixed model repeated measures ANOVA indicated that participants in both FitMindKit and the attention control had significant reductions in symptom composite scores. Effects were not significantly greater in the FitMindKit program relative to control, either at post-test or 3-month follow-up. No effects were detected for specific decreases in depression, generalized anxiety, social anxiety, panic, suicidal ideation or alcohol/substance use. There were no significant differences between the tailored and static versions in effectiveness or adherence. Participants in the tailored and static conditions were more satisfied than in the control condition, with some evidence favouring the tailored condition. High attrition reduced power to find effects. Conclusions: FitMindKit provides a model for addressing comorbid mental health symptoms in an online program, using automated tailoring to symptom patterns. Modifications to the program are recommended, along with the need for

  7. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  8. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  9. C-peptide comparative radioimmunoassays: a study of three commercial kits

    International Nuclear Information System (INIS)

    Villaume, C.; Beck, B.

    1983-01-01

    Plasma C-peptide immunoreactivity (CPR) was measured in 18 fasting subjects with three different commercial kits (RIA-mat C-peptide-, Byk-Mallinckrodt; RIA-gnost-hC-peptide, Hoechst-Behring; human C-peptide radioimmunoassay kit, Novo) The subjects were chosen as to cover a wide range of CPR concentrations (five healthy subjects, six obese subjects, three insulin-dependent diabetics, four normal subjects whose plasmas had been kept at - 20 0 C for periods of 16 or 36 months). CPR was measured with the Novo kit in eight other plasmas which were kept over a period of 36 months, with or without aprotinin. Good correlations have been established among the values found with the three kits. However, absolute concentration values for each subject as well as the dispersion of all plasma C-peptide values varied as a function of the kit used because of antibody specificity differences and because of the various separation methods. The normal range proposed changes with each kit and the blood CPR of a subject can be a normal, reduced or increased one, depending on the kit used. After several months of storage, plasma CPR degradation is observed with the three kits. A protease-inhibitor is necessary in order to avoid this C-peptide degradation due to the apparent existence of a plasma proteolytic enzyme

  10. Expression of c-kit in common benign and malignant breast lesions.

    Science.gov (United States)

    Kondi-Pafiti, Agatha; Arkadopoulos, Nikolaos; Gennatas, Constantinos; Michalaki, Vassiliki; Frangou-Plegmenou, Matrona; Chatzipantelis, Paschalis

    2010-01-01

    c-kit (CD117) is a transmembrane tyrosine kinase that acts as a type III receptor for mast cell growth factor. In recent years, the role of c-kit in the development of preinvasive and invasive breast carcinomas has been investigated. The aim of our study was to detect c-kit expression in the entire spectrum of common benign and malignant breast lesions in correlation with a well-studied myoepithelial or stem-cell like marker (p63). We evaluated 270 cases of benign and malignant breast lesions including fibrocystic disease, fibroadenoma, sclerosing adenosis, atypical ductal hyperplasia, ductal/lobular carcinoma in situ, and ductal/lobular/mixed type carcinoma. C-kit staining was evaluated in the cytoplasm/cell membrane in epithelial and myoepithelial cells and p63 in the nuclei of myoepithelial cells. c-kit was highly expressed (85.3%) in benign lesions (fibrocystic disease, sclerosing adenosis, fibroadenoma), and p63 expression was 95.5% in the aforementioned lesions. c-kit distribution in preinvasive and invasive lesions was as follows: ductal/lobular carcinoma in-situ, 43%/35%; ductal/lobular carcinoma, 36%/39%; and mixed type carcinoma, 20%. c-kit was highly expressed in myofibroblast/fibroblast cells only in grade III ductal/lobular carcinomas. c-kit was totally absent in stromal cells in benign lesions and in situ carcinomas whereas expression was weak in grade I and II carcinomas. Combined overexpression of c-kit and p63 is indicative of benign breast lesions. In contrast, there is reduced expression of c-kit in in situ and invasive breast carcinomas, with simultaneous overexpression in the stromal cells. This suggests that c-kit may play a role in breast cancer progression.

  11. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    Science.gov (United States)

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  12. Nociceptive tuning by stem cell factor/c-Kit signaling.

    Science.gov (United States)

    Milenkovic, Nevena; Frahm, Christina; Gassmann, Max; Griffel, Carola; Erdmann, Bettina; Birchmeier, Carmen; Lewin, Gary R; Garratt, Alistair N

    2007-12-06

    The molecular mechanisms regulating the sensitivity of sensory circuits to environmental stimuli are poorly understood. We demonstrate here a central role for stem cell factor (SCF) and its receptor, c-Kit, in tuning the responsiveness of sensory neurons to natural stimuli. Mice lacking SCF/c-Kit signaling displayed profound thermal hypoalgesia, attributable to a marked elevation in the thermal threshold and reduction in spiking rate of heat-sensitive nociceptors. Acute activation of c-Kit by its ligand, SCF, resulted in a reduced thermal threshold and potentiation of heat-activated currents in isolated small-diameter neurons and thermal hyperalgesia in mice. SCF-induced thermal hyperalgesia required the TRP family cation channel TRPV1. Lack of c-Kit signaling during development resulted in hypersensitivity of discrete mechanoreceptive neuronal subtypes. Thus, c-Kit can now be grouped with a small family of receptor tyrosine kinases, including c-Ret and TrkA, that control the transduction properties of sensory neurons.

  13. Expression of proto-oncogene KIT is up-regulated in subset of human meningiomas

    Directory of Open Access Journals (Sweden)

    Saini Masum

    2012-06-01

    Full Text Available Abstract Background KIT is a proto-oncogene involved in diverse neoplastic processes. Aberrant kinase activity of the KIT receptor has been targeted by tyrosine kinase inhibitor (TKI therapy in different neoplasias. In all the earlier studies, KIT expression was reported to be absent in meningiomas. However, we observed KIT mRNA expression in some meningioma cases. This prompted us to undertake its detailed analyses in meningioma tissues resected during 2008–2009. Methods Tumor tissues and matched peripheral blood samples collected from meningioma patients were used for detailed molecular analyses. KIT expression was ascertained immunohistochemically and validated by immunoblotting. KIT and KITLG transcript levels were discerned by reverse transcription quantitative real-time PCR (RT-qPCR. Similarly, KIT amplification and allele loss were assessed by quantitative real-time (qPCR and validated by fluorescence in situ hybridization (FISH on the neoplastic tissues. Possible alterations of the gene at the nucleotide level were analyzed by sequencing. Results Contrary to earlier reports, KIT expression, was detected immunohistochemically in 20.6% meningioma cases (n = 34. Receptor (KIT and ligand (KITLG transcripts monitored by RT-qPCR were found to co-express (p = 0.048 in most of the KIT immunopositive tumors. 1/7 KIT positive meningiomas showed allele loss corroborated by reduced FISH signal in the corresponding neoplastic tissue. Sequence analysis of KIT showed M541L substitution in exon 10, in one of the immunopositive cases. However, its biological consequence remains to be uncovered. Conclusions This study clearly demonstrates KIT over-expression in the human meningiomas. The data suggest that up-regulated KIT transcription (p  0.05, is a likely mechanism responsible for altered KIT expression. Thus, KIT is a potential candidate for detailed investigation in the context of meningioma pathogenesis.

  14. Expression of proto-oncogene KIT is up-regulated in subset of human meningiomas

    International Nuclear Information System (INIS)

    Saini, Masum; Jha, Ajaya Nand; Abrari, Andleeb; Ali, Sher

    2012-01-01

    KIT is a proto-oncogene involved in diverse neoplastic processes. Aberrant kinase activity of the KIT receptor has been targeted by tyrosine kinase inhibitor (TKI) therapy in different neoplasias. In all the earlier studies, KIT expression was reported to be absent in meningiomas. However, we observed KIT mRNA expression in some meningioma cases. This prompted us to undertake its detailed analyses in meningioma tissues resected during 2008–2009. Tumor tissues and matched peripheral blood samples collected from meningioma patients were used for detailed molecular analyses. KIT expression was ascertained immunohistochemically and validated by immunoblotting. KIT and KITLG transcript levels were discerned by reverse transcription quantitative real-time PCR (RT-qPCR). Similarly, KIT amplification and allele loss were assessed by quantitative real-time (qPCR) and validated by fluorescence in situ hybridization (FISH) on the neoplastic tissues. Possible alterations of the gene at the nucleotide level were analyzed by sequencing. Contrary to earlier reports, KIT expression, was detected immunohistochemically in 20.6% meningioma cases (n = 34). Receptor (KIT) and ligand (KITLG) transcripts monitored by RT-qPCR were found to co-express (p = 0.048) in most of the KIT immunopositive tumors. 1/7 KIT positive meningiomas showed allele loss corroborated by reduced FISH signal in the corresponding neoplastic tissue. Sequence analysis of KIT showed M541L substitution in exon 10, in one of the immunopositive cases. However, its biological consequence remains to be uncovered. This study clearly demonstrates KIT over-expression in the human meningiomas. The data suggest that up-regulated KIT transcription (p < 0.001), instead of gene amplification (p > 0.05), is a likely mechanism responsible for altered KIT expression. Thus, KIT is a potential candidate for detailed investigation in the context of meningioma pathogenesis

  15. 21 CFR 866.2480 - Quality control kit for culture media.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for culture media. 866.2480... control kit for culture media. (a) Identification. A quality control kit for culture media is a device...-dried, viable microorganism, intended for medical purposes to determine if a given culture medium is...

  16. Supply kits for antenatal and childbirth care: a systematic review.

    Science.gov (United States)

    Aleman, Alicia; Tomasso, Giselle; Cafferata, María Luisa; Colomar, Mercedes; Betran, Ana Pilar

    2017-12-13

    It is critical to increase the uptake of interventions proven to be effective to improve maternal and perinatal outcomes. Supply kits have been suggested to be a feasible strategy designed to ensure timely availability and effective follow-up of care. We conducted a systematic review to summarize the evidence on the uptake, effectiveness and safety of supply kits for maternal care. MEDLINE, the Cochrane Pregnancy and Childbirth Group's Trials Register, Campbell Collaboration, Lilacs, Embase and unpublished studies were searched. Studies that reported the efficacy, safety and use of supply kits for maternal healthcare were eligible. Participants were pregnant women or in childbirth. Supply kits were defined as a collection of medicines, supplies or instruments packaged together with the aim of conducting a healthcare task. Two reviewers independently performed the screening, data extraction, and methodological and quality assessment. 24 studies were included: 4 of them were systematic reviews and 20 primary studies. Eighteen studies evaluated a so-called "clean delivery kit". In all but two studies, the kits were used by more than half of the participants. A meta-analysis was deemed inappropriate due to the heterogeneity in study design, in the components of the interventions implemented, in the content of the kits, and in outcomes. Nine studies assessed neonatal outcomes and found statistically significant reductions in cord infection, sepsis and tetanus-related mortality in the intervention group. Three studies showed evidence of reduced neonatal mortality (OR 0.52, 0.60 and 0.71) with statistically significant confidence intervals in all cases. Four studies reported odd ratios for maternal mortality, but only one showed evidence of a statistically significant decrease in this outcome but it was ascribed to hand washing prior to childbirth and not with the use of kits. This review suggests potential benefits in the use of supply kits to improve maternal and

  17. The Quality Lighting Teaching Kit: enlightening our future

    Science.gov (United States)

    Walker, Constance E.; Pompea, Stephen M.

    2016-09-01

    The U.S. National Optical Astronomy Observatory's Education and Public Outreach group has produced a Quality Lighting Teaching (QLT) Kit, as an outcome of the International Year of Light 2015. The kits are designed around problem-based learning scenarios. The kit's six activities allow students to address real lighting problems that relate to wildlife, sky glow, aging eyes, energy consumption, safety, and light trespass. The activities are optimized for 11-14 year olds but can be expanded to younger and older. Most of the activities can be done within in a few minutes with the exception of the Energy Activity. The activities can be done during class or afterschool and as stations (that the students rotate through) or as stand-alones (one at a time). All aspects of the program are as ready-for-use. Everything you need for the six activities is included in the kit. Tutorial videos (on the program's webpage) have been created on how to do the activities. They can be found on the webpage, www.noao.edu/education/qltkit.php. Fourteen Google+ Hangouts on Air have been offered, addressing questions on the activities and logistics. Assessments (in the form of pre- and post-surveys for the students and as post-surveys for the instructors) provide learning outcomes and improvements. Eighty-nine out of 100 kits have been distributed to SPIE, OSA, CIE, IDA and the IAU in 31 countries. The QLT Kit is a stepping-stone to bring awareness to the (younger) public on how quality lighting locally can redress issues like light pollution globally.

  18. Liquid kit for preparation of 188rhenium-etidronate

    International Nuclear Information System (INIS)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto

    2005-01-01

    The aim of this study was the preparation of a liquid kit for radiolabeling of 188 Re-HEDP (hydroxyethylidene diphosphonate). 188 Re was obtained from alumina based 188 W/ 188 Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of 188 Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  19. World Disarmament Kit.

    Science.gov (United States)

    Woito, Robert, Ed.

    This kit presents a comprehensive introduction for students to arms control and disarmament issues. Included are copies of published and unpublished articles for each topic. Section I provides a self-survey to enable students to assess their own attitudes, values, and knowledge. The survey poses questions for which students select one of several…

  20. Preparation of acid-base bifunctional mesoporous KIT-6 (KIT: Korea Advanced Institute of Science and Technology) and its catalytic performance in Knoevenagel reaction

    International Nuclear Information System (INIS)

    Xu, Ling; Wang, Chunhua; Guan, Jingqi

    2014-01-01

    Acid-base bifunctional mesoporous catalysts Al-KIT-6-NH 2 containing different aluminum content have been synthesized through post synthetic grafting method. The materials were characterized by X-ray diffraction (XRD), scanning electron micrographs (SEM), transmission electron micrographs (TEM), Fourier-transform infrared spectroscopy (FTIR), IR spectra of pyridine adsorption, NH 3 -TPD and TG analysis. The characterization results indicated that the pore structure of KIT-6 was well kept after the addition of aluminum and grafting of aminopropyl groups. The acid amount of Al-KIT-6 increased with enhancing aluminum content. Catalytic results showed that weak acid and weak base favor the Knoevenagel reaction, while catalysts with strong acid and weak base exhibited worse catalytic behavior. - Graphical abstract: The postulated steps of mechanism for the acid-base catalyzed process are as follows: (1) the aldehyde gets activated by the surface acidic sites which allow the amine undergoes nucleophilic to attack the carbonyl carbon of benzaldehyde. (2) Water is released in the formation of imine intermediate. (3) The ethyl cyanoacetate reacts with the intermediate. (4) The benzylidene ethyl cyanoacetate is formed and the amine is regenerated. - Highlights: • KIT-6 and Al-KIT-6-NH 2 with different Si/Al ratios has been successfully prepared. • 79.4% Yield was obtained over 46-Al-KIT-6-NH 2 within 20 min in Knoevenagel reaction. • Low Al-content Al-KIT-6-NH 2 shows better catalytic stability than high Al-content catalysts. • There is acid-base synergistic effect in Knoevenagel reaction

  1. Preparation of acid-base bifunctional mesoporous KIT-6 (KIT: Korea Advanced Institute of Science and Technology) and its catalytic performance in Knoevenagel reaction

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Ling [College of Chemistry and Chemical Engineering, Inner Mongolia University for Nationalities, Tongliao 028000 (China); Wang, Chunhua [Key Laboratory of Surface and Interface Chemistry of Jilin Province, College of Chemistry, Jilin University, Changchun 130023 (China); Guan, Jingqi, E-mail: guanjq@jlu.edu.cn [Key Laboratory of Surface and Interface Chemistry of Jilin Province, College of Chemistry, Jilin University, Changchun 130023 (China)

    2014-05-01

    Acid-base bifunctional mesoporous catalysts Al-KIT-6-NH{sub 2} containing different aluminum content have been synthesized through post synthetic grafting method. The materials were characterized by X-ray diffraction (XRD), scanning electron micrographs (SEM), transmission electron micrographs (TEM), Fourier-transform infrared spectroscopy (FTIR), IR spectra of pyridine adsorption, NH{sub 3}-TPD and TG analysis. The characterization results indicated that the pore structure of KIT-6 was well kept after the addition of aluminum and grafting of aminopropyl groups. The acid amount of Al-KIT-6 increased with enhancing aluminum content. Catalytic results showed that weak acid and weak base favor the Knoevenagel reaction, while catalysts with strong acid and weak base exhibited worse catalytic behavior. - Graphical abstract: The postulated steps of mechanism for the acid-base catalyzed process are as follows: (1) the aldehyde gets activated by the surface acidic sites which allow the amine undergoes nucleophilic to attack the carbonyl carbon of benzaldehyde. (2) Water is released in the formation of imine intermediate. (3) The ethyl cyanoacetate reacts with the intermediate. (4) The benzylidene ethyl cyanoacetate is formed and the amine is regenerated. - Highlights: • KIT-6 and Al-KIT-6-NH{sub 2} with different Si/Al ratios has been successfully prepared. • 79.4% Yield was obtained over 46-Al-KIT-6-NH{sub 2} within 20 min in Knoevenagel reaction. • Low Al-content Al-KIT-6-NH{sub 2} shows better catalytic stability than high Al-content catalysts. • There is acid-base synergistic effect in Knoevenagel reaction.

  2. Iodobell in vivo kits for labelling with 123I or 131I

    International Nuclear Information System (INIS)

    Koernyei, J.; Horvath, M.; Pszota, A.; Lakatos, M.; Szirtes, L.

    1988-01-01

    Iodobell in vivo kits provide an easy and fast method for 'on the spot' radioiodination with 123 I (or 131 I). Until now three kits have been developed in the Institute of Isotopes Budapest, the heptadecanoic acid, the hippurate and the MIBG kits. From these, the heptadecanoic acid kit is being tested in humans in Hungary, the other two are under the registration procedure. The Iodobell in vivo kits may contribute to the application of 123 I radioisotope in Hungary. (orig.)

  3. Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors

    International Nuclear Information System (INIS)

    Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma

    2006-01-01

    Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs

  4. Evaluation of the Coca-Cola company travel health kit.

    Science.gov (United States)

    Harper, Lynne A; Bettinger, Julie; Dismukes, Roberta; Kozarsky, Phyllis E

    2002-01-01

    The Coca-Cola travel health kit has been used for about one decade for international travelers and required evaluation to see if the items contained were appropriate for the employees. Two hundred thirty-four travelers were sampled and filled out a voluntary survey including questions about demographic information, travel history, and usage and value of the contents of the travel health kit. One hundred eighty-one surveys were returned; 65% of the respondents were male, and the majority of travelers were between the ages of 36 and 45 years. The most useful items were analgesics and medications used for gastrointestinal problems. In general, the items identified as being the least useful were those requiring specialized use by a medical practitioner, such as needles and syringes. Suggestions of items to be added to the kit included vitamins, cough drops, sleep aids, and eye drops. A surprising result that Coca-Cola employees expressed the desire for brand name rather than generic items. Evaluation of the Coca-Cola Company travel health kit revealed it to be very useful to most corporate travelers. Suggestions that were made will be taken into consideration in designing a new kit, and consideration is being given to whether a basic travel health kit should be provided to which travelers can add other items depending on their personal needs.

  5. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  6. Kit W-sh Mutation Prevents Cancellous Bone Loss during Calcium Deprivation.

    Science.gov (United States)

    Lotinun, Sutada; Suwanwela, Jaijam; Poolthong, Suchit; Baron, Roland

    2018-01-01

    Calcium is essential for normal bone growth and development. Inadequate calcium intake increases the risk of osteoporosis and fractures. Kit ligand/c-Kit signaling plays an important role in regulating bone homeostasis. Mice with c-Kit mutations are osteopenic. The present study aimed to investigate whether impairment of or reduction in c-Kit signaling affects bone turnover during calcium deprivation. Three-week-old male WBB6F1/J-Kit W /Kit W-v /J (W/W v ) mice with c-Kit point mutation, Kit W-sh /HNihrJaeBsmJ (W sh /W sh ) mice with an inversion mutation in the regulatory elements upstream of the c-Kit promoter region, and their wild-type controls (WT) were fed either a normal (0.6% calcium) or a low calcium diet (0.02% calcium) for 3 weeks. μCT analysis indicated that both mutants fed normal calcium diet had significantly decreased cortical thickness and cancellous bone volume compared to WT. The low calcium diet resulted in a comparable reduction in cortical bone volume and cortical thickness in the W/W v and W sh /W sh mice, and their corresponding controls. As expected, the low calcium diet induced cancellous bone loss in the W/W v mice. In contrast, W sh /W sh cancellous bone did not respond to this diet. This c-Kit mutation prevented cancellous bone loss by antagonizing the low calcium diet-induced increase in osteoblast and osteoclast numbers in the W sh /W sh mice. Gene expression profiling showed that calcium deficiency increased Osx, Ocn, Alp, type I collagen, c-Fms, M-CSF, and RANKL/OPG mRNA expression in controls; however, the W sh mutation suppressed these effects. Our findings indicate that although calcium restriction increased bone turnover, leading to osteopenia, the decreased c-Kit expression levels in the W sh /W sh mice prevented the low calcium diet-induced increase in cancellous bone turnover and bone loss but not the cortical bone loss.

  7. Data on quantification of signaling pathways activated by KIT and PDGFRA mutants

    Directory of Open Access Journals (Sweden)

    Christelle Bahlawane

    2016-12-01

    Full Text Available The present data are related to the article entitled “Insights into ligand stimulation effects on gastro-intestinal stromal tumors signaling” (C. Bahlawane, M. Schmitz, E. Letellier, K. Arumugam, N. Nicot, P.V. Nazarov, S. Haan, 2016 [1]. Constitutive and ligand-derived signaling pathways mediated by KIT and PDGFRA mutated proteins found in gastrointestinal stromal tumors (GIST were compared. Expression of mutant proteins was induced by doxycycline in an isogenic background (Hek293 cells. Kit was identified by FACS at the cell surface and found to be quickly degraded or internalized upon SCF stimulation for both Kit Wild type and Kit mutant counterparts. Investigation of the main activated pathways in GIST unraveled a new feature specific for oncogenic KIT mutants, namely their ability to be further activated by Kit ligand, the stem cell factor (scf. We were also able to identify the MAPK pathway as the most prominent target for a common inhibition of PDGFRA and KIT oncogenic signaling. Western blotting and micro-array analysis were applied to analyze the capacities of the mutant to induce an effective STATs response. Among all Kit mutants, only Kit Ex11 deletion mutant was able to elicit an effective STATs response whereas all PDGFRA were able to do so.

  8. Multilateral disarmament verification

    International Nuclear Information System (INIS)

    Persbo, A.

    2013-01-01

    Non-governmental organisations, such as VERTIC (Verification Research, Training and Information Centre), can play an important role in the promotion of multilateral verification. Parties involved in negotiating nuclear arms accords are for the most part keen that such agreements include suitable and robust provisions for monitoring and verification. Generally progress in multilateral arms control verification is often painstakingly slow, but from time to time 'windows of opportunity' - that is, moments where ideas, technical feasibility and political interests are aligned at both domestic and international levels - may occur and we have to be ready, so the preparatory work is very important. In the context of nuclear disarmament, verification (whether bilateral or multilateral) entails an array of challenges, hurdles and potential pitfalls relating to national security, health, safety and even non-proliferation, so preparatory work is complex and time-greedy. A UK-Norway Initiative was established in order to investigate the role that a non-nuclear-weapon state such as Norway could potentially play in the field of nuclear arms control verification. (A.C.)

  9. ConKit: a python interface to contact predictions.

    Science.gov (United States)

    Simkovic, Felix; Thomas, Jens M H; Rigden, Daniel J

    2017-07-15

    Recent advances in protein residue contact prediction algorithms have led to the emergence of many new methods and a variety of file formats. We present ConKit , an open source, modular and extensible Python interface which allows facile conversion between formats and provides an interface to analyses of sequence alignments and sets of contact predictions. ConKit is available via the Python Package Index. The documentation can be found at http://www.conkit.org . ConKit is licensed under the BSD 3-Clause. hlfsimko@liverpool.ac.uk or drigden@liverpool.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  10. Personalized Thematic Kits

    Science.gov (United States)

    Bontrager, Sharon

    2010-01-01

    Teaching Spanish at the K-5 level is a passion of mine, and the author would like to share some of the practical applications that she finds most rewarding and effective. She has found enthusiastic response to the creation of detailed language learning kits that are rooted in storytelling, but expanded to include home-made board games,…

  11. How to define the tool kit for the corrective maintenance service? : a tool kit definition model under the service performance criterion

    NARCIS (Netherlands)

    Chen, Denise

    2009-01-01

    Currently, the rule of defining tool kits is varied and more engineer's aspects oriented. However, the decision of the tool kit's definition is a trade-off problem between the cost and the service performance. This project is designed to develop a model that can integrate the engineer's preferences

  12. Modification the ELISA Kit for diagnosis of “Pseudomonas aeruginosa and comparing it with ordinary ELISA kit”

    Directory of Open Access Journals (Sweden)

    Taghreed A. Mohammad

    2017-07-01

    Full Text Available The first aim of the present study was to diagnosis Pseudomonas  aeruginosa by many tests. This study consisted "200 patients " who suffered from burn wound and compare with 100 health individuals (male and female as a control group, Vitek test was used to diagnose  118 (87 "local isolate  ATCC 15692" with 31 other isolate of Pseudomonas  aeruginosa  ((ATCC 15690, ATCC 15688  from 200 samples which were taken from burn patients. This result was similar to Analytical profile index ( API   test (118 isolates of  P. aeruginosa with 82 isolations of  other bacteria. Then the detection P. aeruginosa isolate  ATCC 15692 by new ELISA Technique and comparing its with modify the ordinary ELISA kit.

  13. Receptor tyrosine kinase (c-Kit inhibitors: a potential therapeutic target in cancer cells

    Directory of Open Access Journals (Sweden)

    Abbaspour Babaei M

    2016-08-01

    Full Text Available Maryam Abbaspour Babaei,1 Behnam Kamalidehghan,2,3 Mohammad Saleem,4–6 Hasniza Zaman Huri,1,7 Fatemeh Ahmadipour1 1Department of Pharmacy, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia; 2Department of Medical Genetics, National Institute of Genetic Engineering and Biotechnology (NIGEB, Shahrak-e Pajoohesh, 3Medical Genetics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran; 4Department of Urology, 5Department of Laboratory Medicine and Pathology, Masonic Cancer Center, University of Minnesota, 6Section of Molecular Therapeutics & Cancer Health Disparity, The Hormel Institute, Austin, MN, USA; 7Clinical Investigation Centre, University Malaya Medical Centre, Lembah Pantai, Kuala Lumpur, Malaysia Abstract: c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit

  14. Mutational status of EGFR and KIT in thymoma and thymic carcinoma.

    Science.gov (United States)

    Yoh, Kiyotaka; Nishiwaki, Yutaka; Ishii, Genichiro; Goto, Koichi; Kubota, Kaoru; Ohmatsu, Hironobu; Niho, Seiji; Nagai, Kanji; Saijo, Nagahiro

    2008-12-01

    This study was conducted to evaluate the prevalence of EGFR and KIT mutations in thymomas and thymic carcinomas as a means of exploring the potential for molecularly targeted therapy with tyrosine kinase inhibitors. Genomic DNA was isolated from 41 paraffin-embedded tumor samples obtained from 24 thymomas and 17 thymic carcinomas. EGFR exons 18, 19, and 21, and KIT exons 9, 11, 13, and 17, were analyzed for mutations by PCR and direct sequencing. Protein expression of EGFR and KIT was evaluated immunohistochemically. EGFR mutations were detected in 2 of 20 thymomas, but not in any of the thymic carcinomas. All of the EGFR mutations detected were missense mutations (L858R and G863D) in exon 21. EGFR protein was expressed in 71% of the thymomas and 53% of the thymic carcinomas. The mutational analysis of KIT revealed only a missense mutation (L576P) in exon 11 of one thymic carcinoma. KIT protein was expressed in 88% of the thymic carcinomas and 0% of the thymomas. The results of this study indicate that EGFR and KIT mutations in thymomas and thymic carcinomas are rare, but that many of the tumors express EGFR or KIT protein.

  15. Opportunities of the energy revolution. Scientific contributions to the KIT

    International Nuclear Information System (INIS)

    Breh, Wolfgang; Schaetzler, Katharina

    2013-01-01

    ''Opportunities for energy revolution'' was the title under which the KIT Energy Center of Karlsruhe Institute of Technology (KIT) in May 2012 held its first annual meeting. The meeting covered the whole Topic of the KIT Energy Center. The present proceedings give those interested the opportunity to delve into the contributions and to provide a differentiated picture of the challenges and opportunities of the energy transition.

  16. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung

    2000-01-01

    Although α-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for α-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for α-fetoprotein (Riakey AFP IRMA CT R , Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum α-fetoprotein measurement using Riakey AFP IRMA CT R kit. The values of α-fetoprotein measured by Riakey AFP IRMA CT R kit were compared with those measured by two foreign commercial kits (α-fetoproteina of Radim and α-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100±10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of α-fetoprotein by Riakey AFP IRMA CT R and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for α-fetoprotein, Riakey AFP IRMA CT R , performed well for clinical use.=20

  17. Development of MIBI kit for heart imaging

    International Nuclear Information System (INIS)

    Khamis, S.B.; Ab-Wahid, M.

    1998-01-01

    99m Tc-isonitriles have been shown to be a very promising substitute for Thallium-201 ( 201 TI) for myocardial perfusion imaging. In this study, the lyophilized kit of Methoxyisobutylisonitrile (MIBI) was prepared and labeled with 99m Tc. Several factors affecting the labeling yield such as the kit's stannous content, boiling time during labeling, and the volume of 99m Tc used during reconstitution were also investigated. The radiochemical purity (RCP) determination of the labeled product was analyzed by HPLC, solvent-extraction, TLC and ITLC-SG chromatographic methods in various systems. Animal biodistribution study performed in rats indicated the 99m Tc-MIBI accumulation in the myocardial is up to 3 hours with little or no redistribution. Toxicity studies performed indicate no clinical signs of abnormality in mice at injected dose equivalent in amount of 100 times the human dose in proportion to body weight. Stability studies of the labeled complex performed at room temperature showed no change in radiochemical purity (> 95%) 6 hours post-preparation. Compatibility and comparative studies were done using both MINT and commercially available MIBI kits and 99m Tc generator eluates. From the results obtained the MINT produced MIBI kits were found to be comparable in quality to that of commercials. (author)

  18. Embedded software verification and debugging

    CERN Document Server

    Winterholer, Markus

    2017-01-01

    This book provides comprehensive coverage of verification and debugging techniques for embedded software, which is frequently used in safety critical applications (e.g., automotive), where failures are unacceptable. Since the verification of complex systems needs to encompass the verification of both hardware and embedded software modules, this book focuses on verification and debugging approaches for embedded software with hardware dependencies. Coverage includes the entire flow of design, verification and debugging of embedded software and all key approaches to debugging, dynamic, static, and hybrid verification. This book discusses the current, industrial embedded software verification flow, as well as emerging trends with focus on formal and hybrid verification and debugging approaches. Includes in a single source the entire flow of design, verification and debugging of embedded software; Addresses the main techniques that are currently being used in the industry for assuring the quality of embedded softw...

  19. Autometallography: tissue metals demonstrated by a silver enhancement kit

    DEFF Research Database (Denmark)

    Danscher, G; Nørgaard, J O; Baatrup, E

    1987-01-01

    , primarily intended for the amplification of colloidal gold particles, has been used to demonstrate these catalytic tissue metals. Sections from animals exposed intravitally to aurothiomalatate, silver lactate, mercury chloride, sodium selenite or perfused with sodium sulphide were subjected to a commercial......In biological tissue, minute accumulations of gold, silver, mercury and zinc can be visualized by a technique whereby metallic silver is precipitated on tiny accumulations of the two noble metals, or on selenites or sulphides of all four metals. In the present study a silver enhancement kit...... silver enhancement kit (IntenSE, Janssen Pharmaceutica). It was found that the kit performs adequately to the silver lactate gum arabic developer and to the photographic emulsion technique. The kit can be used as a silver enhancement medium for the demonstration of zinc by the Neo-Timm and selenium...

  20. Gene Duplication of the zebrafish kit ligand and partitioning of melanocyte development functions to kit ligand a.

    Directory of Open Access Journals (Sweden)

    Keith A Hultman

    2007-01-01

    Full Text Available The retention of particular genes after the whole genome duplication in zebrafish has given insights into how genes may evolve through partitioning of ancestral functions. We examine the partitioning of expression patterns and functions of two zebrafish kit ligands, kit ligand a (kitla and kit ligand b (kitlb, and discuss their possible coevolution with the duplicated zebrafish kit receptors (kita and kitb. In situ hybridizations show that kitla mRNA is expressed in the trunk adjacent to the notochord in the middle of each somite during stages of melanocyte migration and later expressed in the skin, when the receptor is required for melanocyte survival. kitla is also expressed in other regions complementary to kita receptor expression, including the pineal gland, tail bud, and ear. In contrast, kitlb mRNA is expressed in brain ventricles, ear, and cardinal vein plexus, in regions generally not complementary to either zebrafish kit receptor ortholog. However, like kitla, kitlb is expressed in the skin during stages consistent with melanocyte survival. Thus, it appears that kita and kitla have maintained congruent expression patterns, while kitb and kitlb have evolved divergent expression patterns. We demonstrate the interaction of kita and kitla by morpholino knockdown analysis. kitla morphants, but not kitlb morphants, phenocopy the null allele of kita, with defects for both melanocyte migration and survival. Furthermore, kitla morpholino, but not kitlb morpholino, interacts genetically with a sensitized allele of kita, confirming that kitla is the functional ligand to kita. Last, we examine kitla overexpression in embryos, which results in hyperpigmentation caused by an increase in the number and size of melanocytes. This hyperpigmentation is dependent on kita function. We conclude that following genome duplication, kita and kitla have maintained their receptor-ligand relationship, coevolved complementary expression patterns, and that

  1. New RIA kit for determination of progesterone in cow milk

    International Nuclear Information System (INIS)

    Byszewska-Szpocinska, E.; Markiewicz, A.

    2006-01-01

    The determination of progesterone concentration in whole and fat-free milk 19-24 days after conception enables to distinguish fertile and non-fertile insemination, which is important in cattle breeding. The aim of this work was to develop a simple and quick radioimmunoassay test for the determination of progesterone in cow milk. Two types of solid-phase tubes coated with specific polyclonal anti-progesterone antibody from ORION Diagnostica and BIOSOURCE International, two different progesterone derivatives viz. progesterone-3- carboxymethyl oxime (CMO) and progesterone-11α-hemisuccinate (HS) conjugated to 125 I-histamine and the HPLC system with Lichrospher RP-18 column along with 65% acetonitrile/water as eluent to purify the tracers were used to carry out this work. Progesterone-3CMO- 125 I-histamine had a retention time of 13.2 min and progesterone-11α-hemisuccinate- 125 I-histamine had a retention time of 7.8 min. Two kinds of kits (kit I and kit II) were prepared, first with progesterone-3CMO- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit of ORION Diagnostica and the second with progesterone-11αHS- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit from BIOSOURCE International. Progesterone from Sigma and selected fat-free cow's milk without progesterone as zero progesterone milk matrix were used for standard preparation. The optimal assay procedure was as follows: 50μL standards, controls and fat-free milk samples were pipetted into coated tubes followed by addition of 500μL of diluted tracer. The tubes were incubated for 2h in case of kit I and 3h for kit II at RT. After the incubation, the tubes were decanted and counted. The assay range was 0 to 270 nmol/L for kit I and 0 to 300 nmol/L for kit II. The sensitivity of the kit with ORION coated tubes was better (0.8 nmol/L) than that of BIOSOURCE tubes which was 1.5 nmol/L. Validation of these assays in terms of specificity, accuracy

  2. Software verification for nuclear industry

    International Nuclear Information System (INIS)

    Wilburn, N.P.

    1985-08-01

    Why verification of software products throughout the software life cycle is necessary is considered. Concepts of verification, software verification planning, and some verification methodologies for products generated throughout the software life cycle are then discussed

  3. The design of verification regimes

    International Nuclear Information System (INIS)

    Gallagher, N.W.

    1991-01-01

    Verification of a nuclear agreement requires more than knowledge of relevant technologies and institutional arrangements. It also demands thorough understanding of the nature of verification and the politics of verification design. Arms control efforts have been stymied in the past because key players agreed to verification in principle, only to disagree radically over verification in practice. In this chapter, it is shown that the success and stability of arms control endeavors can be undermined by verification designs which promote unilateral rather than cooperative approaches to security, and which may reduce, rather than enhance, the security of both sides. Drawing on logical analysis and practical lessons from previous superpower verification experience, this chapter summarizes the logic and politics of verification and suggests implications for South Asia. The discussion begins by determining what properties all forms of verification have in common, regardless of the participants or the substance and form of their agreement. Viewing verification as the political process of making decisions regarding the occurrence of cooperation points to four critical components: (1) determination of principles, (2) information gathering, (3) analysis and (4) projection. It is shown that verification arrangements differ primarily in regards to how effectively and by whom these four stages are carried out

  4. Hearing aids in children: the importance of the verification and validation processes.

    Science.gov (United States)

    Rissatto, Mara Renata; Novaes, Beatriz Cavalcanti de Albuquerque Caiuby

    2009-01-01

    during the fitting of hearing aids in children it is important, besides using a verification protocol, to have a validation process. to describe and discuss the use of a protocol for the fitting and the verification of hearing aids in children, as well as the impact of the adjustment of the acoustic characteristics in speech perception tasks. ten children aging from three to eleven years were enrolled in this study. All children presented bilateral sensorineural hearing impairment, were users of hearing aids and were followed at a public hearing health care service in Bahia. The children were submitted to the following procedures: pure tone air and bone conduction thresholds; real-ear coupler difference (RECD); verification with real-ear measurement equipment: coupler gain/output and insertion gain and to speech perception tasks: 'The Six-Sound Test' (Ling, 2006) and the 'Word Associations for Syllable Perception' (WASP - Koch, 1999). The programmed electro acoustic characteristics of the hearing aids were compared to the electro acoustic characteristics prescribed by the DSL [i/o] v4.1 software. The speech perception tasks were reapplied on three occasions: straight after the modification of the electro acoustic characteristics, after 30 days and 60 days. for more than 50% of the tested children, the programmed electro acoustic characteristics of the hearing aids did not correspond to that suggested by the DSL [i/o] software. Adequate prescription was verified in 70% of the investigated sample; this was also confirmed by the results in the speech perception tasks (p=0.000). This data confirmed that the mean percentage of correct answers increased after the modification of the electro acoustic characteristics. the use of a protocol that verifies and validates the fitting of hearing aids in children is necessary.

  5. Improved verification methods for safeguards verifications at enrichment plants

    International Nuclear Information System (INIS)

    Lebrun, A.; Kane, S. C.; Bourva, L.; Poirier, S.; Loghin, N. E.; Langlands, D.

    2009-01-01

    The International Atomic Energy Agency (IAEA) has initiated a coordinated research and development programme to improve its verification methods and equipment applicable to enrichment plants. The programme entails several individual projects to meet the objectives of the IAEA Safeguards Model Approach for Gas Centrifuge Enrichment Plants updated in 2006. Upgrades of verification methods to confirm the absence of HEU (highly enriched uranium) production have been initiated and, in particular, the Cascade Header Enrichment Monitor (CHEM) has been redesigned to reduce its weight and incorporate an electrically cooled germanium detector. Such detectors are also introduced to improve the attended verification of UF 6 cylinders for the verification of the material balance. Data sharing of authenticated operator weighing systems such as accountancy scales and process load cells is also investigated as a cost efficient and an effective safeguards measure combined with unannounced inspections, surveillance and non-destructive assay (NDA) measurement. (authors)

  6. Improved verification methods for safeguards verifications at enrichment plants

    Energy Technology Data Exchange (ETDEWEB)

    Lebrun, A.; Kane, S. C.; Bourva, L.; Poirier, S.; Loghin, N. E.; Langlands, D. [Department of Safeguards, International Atomic Energy Agency, Wagramer Strasse 5, A1400 Vienna (Austria)

    2009-07-01

    The International Atomic Energy Agency (IAEA) has initiated a coordinated research and development programme to improve its verification methods and equipment applicable to enrichment plants. The programme entails several individual projects to meet the objectives of the IAEA Safeguards Model Approach for Gas Centrifuge Enrichment Plants updated in 2006. Upgrades of verification methods to confirm the absence of HEU (highly enriched uranium) production have been initiated and, in particular, the Cascade Header Enrichment Monitor (CHEM) has been redesigned to reduce its weight and incorporate an electrically cooled germanium detector. Such detectors are also introduced to improve the attended verification of UF{sub 6} cylinders for the verification of the material balance. Data sharing of authenticated operator weighing systems such as accountancy scales and process load cells is also investigated as a cost efficient and an effective safeguards measure combined with unannounced inspections, surveillance and non-destructive assay (NDA) measurement. (authors)

  7. Application of an FSH-RIA-kit in the clinical practice

    International Nuclear Information System (INIS)

    Delzer, W.; Herzmann, H.

    1982-01-01

    First clinical experiences with an FSH-RIA-kit developed in the Central Institute for Isotope- and Radiation Research are reported. Simultaneously carried out LH and FSH determination during the menstruation cycle with special regard of the middle of the cycle revealed increased hormone values in the preovulatory phase. The problem of evaluation of hormone values achieved by different kits (standards), was investigated simultaneous determination of the sera using the own and an imported kit. (author)

  8. The clinical testing of a Hungarian-made triiodothyronine radioimmunoassay kit

    International Nuclear Information System (INIS)

    Gyertyanfy, G.; Foeldes, J.

    1981-01-01

    The parameters of the calibration curve of the new Hungarian RK-11 kit for the determination of the total T3 content of the serum and the reliability of the results were studied. The data of the measurements made on a number of patients by RK-11, Biodata and Byk-Mallinckrodt kits were compared. The new kit seems to be applicable to the determination of the total T3 content in the serum. (author)

  9. Signaling by Kit protein-tyrosine kinase--the stem cell factor receptor.

    Science.gov (United States)

    Roskoski, Robert

    2005-11-11

    Signaling by stem cell factor and Kit, its receptor, plays important roles in gametogenesis, hematopoiesis, mast cell development and function, and melanogenesis. Moreover, human and mouse embryonic stem cells express Kit transcripts. Stem cell factor exists as both a soluble and a membrane-bound glycoprotein while Kit is a receptor protein-tyrosine kinase. The complete absence of stem cell factor or Kit is lethal. Deficiencies of either produce defects in red and white blood cell production, hypopigmentation, and sterility. Gain-of-function mutations of Kit are associated with several human neoplasms including acute myelogenous leukemia, gastrointestinal stromal tumors, and mastocytomas. Kit consists of an extracellular domain, a transmembrane segment, a juxtamembrane segment, and a protein kinase domain that contains an insert of about 80 amino acid residues. Binding of stem cell factor to Kit results in receptor dimerization and activation of protein kinase activity. The activated receptor becomes autophosphorylated at tyrosine residues that serve as docking sites for signal transduction molecules containing SH2 domains. The adaptor protein APS, Src family kinases, and Shp2 tyrosyl phosphatase bind to phosphotyrosine 568. Shp1 tyrosyl phosphatase and the adaptor protein Shc bind to phosphotyrosine 570. C-terminal Src kinase homologous kinase and the adaptor Shc bind to both phosphotyrosines 568 and 570. These residues occur in the juxtamembrane segment of Kit. Three residues in the kinase insert domain are phosphorylated and attract the adaptor protein Grb2 (Tyr703), phosphatidylinositol 3-kinase (Tyr721), and phospholipase Cgamma (Tyr730). Phosphotyrosine 900 in the distal kinase domain binds phosphatidylinositol 3-kinase which in turn binds the adaptor protein Crk. Phosphotyrosine 936, also in the distal kinase domain, binds the adaptor proteins APS, Grb2, and Grb7. Kit has the potential to participate in multiple signal transduction pathways as a result of

  10. Microgripper construction kit

    Science.gov (United States)

    Gengenbach, Ulrich K.; Hofmann, Andreas; Engelhardt, Friedhelm; Scharnowell, Rudolf; Koehler, Bernd

    2001-10-01

    A large number of microgrippers has been developed in industry and academia. Although the importance of hybrid integration techniques and hence the demand for assembly tools grows continuously a large part of these developments has not yet been used in industrial production. The first grippers developed for microassembly were basically vacuum grippers and downscaled tweezers. Due to increasingly complex assembly tasks more and more functionality such as sensing or additional functions such as adhesive dispensing has been integrated into gripper systems over the last years. Most of these gripper systems are incompatible since there exists no standard interface to the assembly machine and no standard for the internal modules and interfaces. Thus these tools are not easily interchangeable between assembly machines and not easily adaptable to assembly tasks. In order to alleviate this situation a construction kit for modular microgrippers is being developed. It is composed of modules with well defined interfaces that can be combined to build task specific grippers. An abstract model of a microgripper is proposed as a tool to structure the development of the construction kit. The modular concept is illustrated with prototypes.

  11. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    Although {alpha}-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for {alpha}-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for {alpha}-fetoprotein (Riakey AFP IRMA CT{sup R}, Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum {alpha}-fetoprotein measurement using Riakey AFP IRMA CT{sup R} kit. The values of {alpha}-fetoprotein measured by Riakey AFP IRMA CT{sup R} kit were compared with those measured by two foreign commercial kits ({alpha}-fetoproteina of Radim and {alpha}-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100{+-}10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of {alpha}-fetoprotein by Riakey AFP IRMA CT{sup R} and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for {alpha}-fetoprotein, Riakey AFP IRMA CT{sup R}, performed well for clinical use.

  12. Physics Verification Overview

    Energy Technology Data Exchange (ETDEWEB)

    Doebling, Scott William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-12

    The purpose of the verification project is to establish, through rigorous convergence analysis, that each ASC computational physics code correctly implements a set of physics models and algorithms (code verification); Evaluate and analyze the uncertainties of code outputs associated with the choice of temporal and spatial discretization (solution or calculation verification); and Develop and maintain the capability to expand and update these analyses on demand. This presentation describes project milestones.

  13. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    OpenAIRE

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-01-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an i...

  14. Metering and energy audit : the key to success; Mesurage et verification energetique : la cle du succes

    Energy Technology Data Exchange (ETDEWEB)

    Milot, J. [Econoler, Quebec, PQ (Canada)

    2010-01-01

    The most widely used measurement and verification (M and V) procedure for energy performance contracting (EPC) projects is the International Performance Measurement and Verification Protocol (IPMVP). This article discussed the IPMVP as a tool for measuring the success of energy efficiency projects. The IPMVP provides an overview of current best practice techniques available for verifying results of energy efficiency, water efficiency and renewable energy projects in commercial and industrial facilities. Facility operators can use the IPMVP to evaluate and improve facility performance. Energy conservation measures (ECMs) covered in the protocol include fuel saving measures, water efficiency measures, load shifting and energy reductions through installation or retrofit of equipment, or modification of operating procedures. 2 figs.

  15. DESIGN INFORMATION VERIFICATION FOR NUCLEAR SAFEGUARDS

    Energy Technology Data Exchange (ETDEWEB)

    Robert S. Bean; Richard R. M. Metcalf; Phillip C. Durst

    2009-07-01

    A critical aspect of international safeguards activities performed by the International Atomic Energy Agency (IAEA) is the verification that facility design and construction (including upgrades and modifications) do not create opportunities for nuclear proliferation. These Design Information Verification activities require that IAEA inspectors compare current and past information about the facility to verify the operator’s declaration of proper use. The actual practice of DIV presents challenges to the inspectors due to the large amount of data generated, concerns about sensitive or proprietary data, the overall complexity of the facility, and the effort required to extract just the safeguards relevant information. Planned and anticipated facilities will (especially in the case of reprocessing plants) be ever larger and increasingly complex, thus exacerbating the challenges. This paper reports the results of a workshop held at the Idaho National Laboratory in March 2009, which considered technologies and methods to address these challenges. The use of 3D Laser Range Finding, Outdoor Visualization System, Gamma-LIDAR, and virtual facility modeling, as well as methods to handle the facility data issues (quantity, sensitivity, and accessibility and portability for the inspector) were presented. The workshop attendees drew conclusions about the use of these techniques with respect to successfully employing them in an operating environment, using a Fuel Conditioning Facility walk-through as a baseline for discussion.

  16. Tumor markers kits development for use in radioimmunometric assays

    International Nuclear Information System (INIS)

    Ahmed, B.

    1997-01-01

    The immunoassays such as RIA and IRMA are now widely used through the world for the quantitation of a variety of substances in the biological fluid for their high sensibility and specificity which required simple equipments. These techniques are also very used in Algeria for an effective amelioration of public heath The assays kits of RIA/IRMA of thyroid hormones are the most used, followed by peptidic hormones, steroids hormones and IRMA Tumor Markers (T.M) kits. In spite of the important demand, of tumor markers kits for the diagnosis and follow up of cancers their use are always insufficient due to the high cost. The research contract programme proposed by IAEA on the theme 'The Developments of IRMA Tumor Markers Kits' of prostate specific Antigen (PSA) and Tissue Polypeptide Specific Antigen (TPS) will allowed us to produce locally with best quality-price, the main reagents for PSA and TPS IRMA assays kits for diagnosis and follow up the prostate and breast cancers which are very spready in the country. This report include the following points: Generalities on the use of tumor markers in Algeria, programme for the Development of the PSA IRMA assay (schedule of protocols applied for each reagents; annual planning for assessing the programme activities) and conclusion

  17. Disposable Collection Kit for Rapid and Reliable Collection of Saliva

    OpenAIRE

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 ?l) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method...

  18. IODOBELL in vivo kits for in situ labelling with iodine

    International Nuclear Information System (INIS)

    Koernyei, Jozsef; Lakatos, Mihaly; Kecskes, Ferenc; Mahunka, Imre; Mikecz, Pal; Ando, Laszlo

    1988-01-01

    A system of in vivo kits called IODOBELL was developed in the Institute of Isotopes, Budapest. The production of hepatodecanoic acid for cardiology, iodo-hippuranic acid for kidney diagnostics and a special pharmaceutical, IODOBELL-MIGB for the indication of feochromocitoma and neuroblastoma is reported. The heptadecanoic acid kit is under human examination, the other two are to be tested in the near future. IODOBELL kits contribute to the wider use of 123 I in Hungary. (author) 6 refs

  19. An improved 99mTc-Aprotinin kit formulation: quality control analysis of cold kit shelf life and radiotracer stability

    International Nuclear Information System (INIS)

    Smyth, D.R.; Tsopelas, C.

    2005-01-01

    Aprotinin is a small protein that inhibits serine proteases and has been shown to bind to amyloid fibrils of varying chemical composition in-vitro. 99 mTc-aprotinin has demonstrated potential for imaging cardiac and pleuropulmonary AL amyloidosis and other forms of amyloidosis present as deposits in joints, the tongue or intestines and other sites excluding the kidneys and liver. Radiolabelling of aprotinin was previously achieved by addition of 99 mTc-pertech-netate to an alkaline mixture of Trasylol (aprotinin injection) and stannous chloride, followed by a necessary filtration step after 20-30 minutes. We have developed a modified cold kit formulation, utilising pharmaceutical starting materials, that provides a more convenient and efficient radiolabelling procedure where filtration is not required prior to injection. The shelf life of the cold kits was validated after storage in a freezer. The reducing agent used was stannous-pyrophosphate (PYP) and the alkaline buffer was a phosphate-glycine mixture (pH 10.5). Quality control testing of the cold kits was performed after 0, 1, 2, 3 and 6 months storage by assessing the % RCP of 99 mTc-apro-tinin by ITLC-SG. Radiotracer stability was examined in the same way 25, 85 and 265 minutes post reconstitution (pr) via a three strip system employing acetone, saline and ammonia:ethanol:water mixture (1:2:5). A rapid quality control cartridge method was also investigated. Radiolabelling of the cold kits yielded RCP > 95% at 25 mins pr and all other time points, from a formulation that avoided a filtration step. The impurities were quantified as TcO., ( 99 mTc-PYP (< 0.7%) by paper methods. The improved Tc-aprotinin kit formulation has greater convenience and efficiency in the clinical setting

  20. Oncogenic activation of v-kit involves deletion of a putative tyrosine-substrate interaction site.

    Science.gov (United States)

    Herbst, R; Munemitsu, S; Ullrich, A

    1995-01-19

    The transforming gene of the Hardy-Zuckerman-4 strain of feline sarcoma virus, v-kit, arose by transduction of the cellular c-kit gene, which encodes the receptor tyrosine kinase (RTK) p145c-kit. To gain insight into the molecular basis of the v-kit transforming potential, we characterized the feline c-kit by cDNA cloning. Comparison of the feline v-kit and c-kit sequences revealed, in addition to deletions of the extracellular and transmembrane domains, three additional mutations in the v-kit oncogene product: deletion of tyrosine-569 and valine-570, the exchange of aspartate at position 761 to glycine, and replacement of the C-terminal 50 amino acids by five unrelated residues. Examinations of individual v-kit mutations in the context of chimeric receptors yielded inhibitory effects for some mutants on both autophosphorylation and substrate phosphorylation functions. In contrast, deletion of tyrosine-569 and valine-570 significantly enhanced transforming and mitogenic activities of p145c-kit, while the other mutations had no significant effects. Conservation in subclass III RTKs and the identification of the corresponding residue in beta PDGF-R, Y579, as a binding site for src family tyrosine kinases suggests an important role for Y568 in kit signal regulation and the definition of its oncogenic potential. Repositioning of Y571 by an inframe two codon deletion may be the crucial alteration resulting in enhancement of v-kit oncogenic activity.

  1. RestKit for iOS standard guide

    CERN Document Server

    Kalapun, Taras

    2013-01-01

    A step-by-step, example-based guide to learning how you can link your apps and web services using RestKit.This book is for iOS developers of all levels who are interested in boosting their productivity by utilizing third party libraries and who have a willingness to learn how to build RESTful apps using the RestKit framework. A basic knowledge of Objective-C is required as well as a simple understanding of how to use CoreData.

  2. Technetium-99m ceftizoxime kit preparation

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento

    2005-01-01

    The aim of this work was to prepare a kit of 99 m Tc-ceftizoxime ( 99m Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99m Tc pertechnetate solution (Na 99m Tc O 4- ) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99m Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99m Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99 m Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99m Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ( 99m Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes. (author)

  3. Late development of homoeothermy in mink (Mustela vison) kits - a strategy for maximum survival rate

    DEFF Research Database (Denmark)

    Tauson, A-H; Chwalibog, André; Tygesen, M P

    2006-01-01

    and after the experiments and evaporative water losses (EWL) were calculated. When exposed to L temperature, single kits responded with a very low HE until 29 days of age, and groups of kits until 14 days of age. It was not until they reached an age of approximately 6 weeks that single kits showed a clear...... thermoregulatory response to the L temperature by increased HE, whereas groups of kits showed increased HE from 29th day onwards. When kept at H temperature, HE was low initially, but all kits showed elevated HE at 8 days of age, and the metabolic rate was similar for single kits and kits huddling in groups....... Evaporative water losses was higher among single than among groups of kits and slightly lower but more variable for animals at L than at H temperature. It was concluded that mink kits develop functional homoeothermy at an age of close to 6 weeks and that the failure of very young kits to thermoregulate...

  4. Solid state nuclear track detectors kit for the use in teaching

    International Nuclear Information System (INIS)

    Khouri, M.T.F.C.; Koskinas, M.F.

    1988-11-01

    The kit intends to improve the possibilities in performing experiments of Nuclear Physics in Modern Physics laboratories of Physics Course introducing the solid state nuclear track detectors. In these materials the passage of heavily ionizing nuclear particles creates paths (tracks) that may be revealed and made visible in an optical microscope. By the help of the kit several experiments and/or demonstrations may be performed. The kit contains solid state nuclear track detectors unirradiated and irradiated, irradiated etched and unetched sheets: an alpha source of 241 Am and an instrution text with photomicrographs. To use the kit the laboratory must have an ordinary optical microscope. (author) [pt

  5. Kit development for labelling erythrocytes or leukocytes with technetium-99m in vitro

    International Nuclear Information System (INIS)

    Wang Xuebin; Han Quansheng; Wang Jingcheng; Mi Hongzhi

    1996-01-01

    This study developed a modified pre tinning method for labeling erythrocytes with technetium-99m in vitro using a kit which contains stannous chloride stabilized with geneticist acid (GA) in lyophilized form. This GA-kit a sterile closed system that does not require centrifugation,washing and separation of the RBCs. The kit is simple to use and labeling takes ∼ 30 min with a typical labeling efficiency of 97.3% ± 1.2% for 60 determinations. Imaging studies were performed in rabbit using GA-kit in vitro labeling procedure and PYP-kit in vivo labeling. It shows that the heart-to-background ratio with GA in vitro labeling were significantly higher than with in vivo labeling. Leukocytes labeling with technetium-99m using the same GA kit also was studied. The labeling efficiency was 20 ∼ 41%. Thus, the GA kit is versatile and cost-effective. (author). 21 refs., 5 figs., 2 tabs

  6. Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.

    Science.gov (United States)

    Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T

    1991-09-01

    Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an in-frame insertion, Gly-Asn-Asn-Lys, within the extracellular domain, was detected in murine mast cell cultures and mid-gestation placenta. Both Kit+ and KitA+ isoforms showed increased autophosphorylation and enhanced association with phosphatidylinositol (PI) 3' kinase and PLC gamma 1, when stimulated with recombinant soluble Steel factor. No association or increase in phosphorylation of GAP and two GAP-associated proteins, p62 and p190, was observed. The two isoforms had distinct activities in the absence of exogenous soluble Steel factor; Kit+, but not KitA+, showed constitutive tyrosine phosphorylation that was accompanied by a low constitutive level of association with PI-3' kinase and PLC gamma 1. Introduction of the point substitutions associated with W37 (Glu582----Lys) or W41 (Val831----Met) mutant alleles into c-kit expression constructs abolished (W37) or reduced (W41) the Steel factor-induced association of the Kit receptor with signalling proteins in a manner proportional to the overall severity of the corresponding W mutant phenotype. These data suggest a diversity of normal Kit signalling pathways and indicate that W mutant phenotypes result from primary defects in the Kit receptor that affect its interaction with cytoplasmic signalling proteins.

  7. Liquid kit for preparation of {sup 188}rhenium-etidronate

    Energy Technology Data Exchange (ETDEWEB)

    Marczewski, Barbara; Dias, Carla Roberta; Moraes, Vanessa; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), SP (Brazil). Centro de Radiofarmacia]. E-mail: baszot@gmail.com

    2005-10-15

    The aim of this study was the preparation of a liquid kit for radiolabeling of {sup 188} Re-HEDP (hydroxyethylidene diphosphonate). {sup 188} Re was obtained from alumina based {sup 188} W/{sup 188} Re generators. This paper reports the efficacy of a cold kit stored for more than two weeks, determined by the dependence of the radiolabeling yields of {sup 188} Re-HEDP on the incubation time, reducing agent concentration, the effects of concentration of ligand, the p H of the reaction and the temperature. The cold kits showed a good stability when carrie-free rhenium-188 was added in the reaction mixture. (author)

  8. Dumpster Optics: teaching and learning optics without a kit

    Science.gov (United States)

    Donnelly, Judy; Magnani, Nancy; Robinson, Kathleen

    2016-09-01

    The Next Generation Science Standards (NGSS) and renewed emphasis on STEM education in the U.S. have resulted in the development of many educational kits for teaching science in general and optics in particular. Many teachers do not have funding to purchase kits and practical experience has shown that even costly kits can have poorly written and misleading instructions and may include experiments that would not work in a classroom. Dumpster Optics lessons are designed to use inexpensive, commonly found materials. All lessons have been field-tested with students. We will describe the development of the lessons, provide examples of field testing experiences and outline possible future activities.

  9. 33 CFR 149.323 - What are the requirements for first aid kits?

    Science.gov (United States)

    2010-07-01

    ... first aid kits? 149.323 Section 149.323 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Lifesaving Equipment Manned Deepwater Port Requirements § 149.323 What are the requirements for first aid kits? (a) Each manned deepwater port must have an industrial first aid kit, approved by an appropriate...

  10. FMCT verification: Case studies

    International Nuclear Information System (INIS)

    Hui Zhang

    2001-01-01

    Full text: How to manage the trade-off between the need for transparency and the concern about the disclosure of sensitive information would be a key issue during the negotiations of FMCT verification provision. This paper will explore the general concerns on FMCT verification; and demonstrate what verification measures might be applied to those reprocessing and enrichment plants. A primary goal of an FMCT will be to have the five declared nuclear weapon states and the three that operate unsafeguarded nuclear facilities become parties. One focus in negotiating the FMCT will be verification. Appropriate verification measures should be applied in each case. Most importantly, FMCT verification would focus, in the first instance, on these states' fissile material production facilities. After the FMCT enters into force, all these facilities should be declared. Some would continue operating to produce civil nuclear power or to produce fissile material for non- explosive military uses. The verification measures necessary for these operating facilities would be essentially IAEA safeguards, as currently being applied to non-nuclear weapon states under the NPT. However, some production facilities would be declared and shut down. Thus, one important task of the FMCT verifications will be to confirm the status of these closed facilities. As case studies, this paper will focus on the verification of those shutdown facilities. The FMCT verification system for former military facilities would have to differ in some ways from traditional IAEA safeguards. For example, there could be concerns about the potential loss of sensitive information at these facilities or at collocated facilities. Eventually, some safeguards measures such as environmental sampling might be seen as too intrusive. Thus, effective but less intrusive verification measures may be needed. Some sensitive nuclear facilities would be subject for the first time to international inspections, which could raise concerns

  11. Inspector measurement verification activities

    International Nuclear Information System (INIS)

    George, R.S.; Crouch, R.

    e most difficult and complex activity facing a safeguards inspector involves the verification of measurements and the performance of the measurement system. Remeasurement is the key to measurement verification activities. Remeasurerements using the facility's measurement system provide the bulk of the data needed for determining the performance of the measurement system. Remeasurements by reference laboratories are also important for evaluation of the measurement system and determination of systematic errors. The use of these measurement verification activities in conjunction with accepted inventory verification practices provides a better basis for accepting or rejecting an inventory. (U.S.)

  12. Integration of SPICE with TEK LV500 ASIC Design Verification System

    Directory of Open Access Journals (Sweden)

    A. Srivastava

    1996-01-01

    Full Text Available The present work involves integration of the simulation stage of design of a VLSI circuit and its testing stage. The SPICE simulator, TEK LV500 ASIC Design Verification System, and TekWaves, a test program generator for LV500, were integrated. A software interface in ‘C’ language in UNIX ‘solaris 1.x’ environment has been developed between SPICE and the testing tools (TekWAVES and LV500. The function of the software interface developed is multifold. It takes input from either SPICE2G.6 or SPICE 3e.1. The output generated by the interface software can be given as an input to either TekWAVES or LV500. A graphical user interface has also been developed with OPENWlNDOWS using Xview tool kit on SUN workstation. As an example, a two phase clock generator circuit has been considered and usefulness of the software demonstrated. The interface software could be easily linked with VLSI design such as MAGIC layout editor.

  13. Verification and disarmament

    Energy Technology Data Exchange (ETDEWEB)

    Blix, H. [IAEA, Vienna (Austria)

    1998-07-01

    The main features are described of the IAEA safeguards verification system that non-nuclear weapon states parties of the NPT are obliged to accept. Verification activities/problems in Iraq and North Korea are discussed.

  14. Verification and disarmament

    International Nuclear Information System (INIS)

    Blix, H.

    1998-01-01

    The main features are described of the IAEA safeguards verification system that non-nuclear weapon states parties of the NPT are obliged to accept. Verification activities/problems in Iraq and North Korea are discussed

  15. Physicochemical characteristics of the kanamycin-lyophilized kit

    International Nuclear Information System (INIS)

    Eva Maria Widyasari; Misyetti; Teguh Hafiz Ambar W; Witri Nuraeni

    2013-01-01

    Kanamycin is a broad-spectrum antibiotic and usually used for the treatment of infections when antibiotics like penicillin are less powerful and can not be given. This research was performed to obtain several physicochemical character of 99m Tc-kanamycin which were made in the form of lyophilized kanamycin kit to ensure the later application in humans. Kanamycin diagnostic kit were provided in lyophilized kit comprising kanamycin as ligand compound, pyrophosphate as co-ligand and SnCl 2 as reducing agent. The radiochemical purity was determined by instant thin layer chromatography (ITLC-SG) using 0.5 N NaOH as the mobile phase and ascending paper chromatography using Whatman paper 3 with acetone as the mobile phase. The plasma binding protein of 99m Tc-kanamycin was investigated in vitro by precipitation method using 5% of trichloro acetic acid (TCA) solution, whereas the lipophilicity (log P) was obtained by determination the partition coefficient in organic solvent-water system. Studies on the effect of the amount of radioactivity and the volume of Na 99m TcO 4 solution to the radiochemical purity of 99m Tc-kanamycin were also performed. From this experiment it was obtained that kanamycin lyophilized-kit was hydrophilic, 59.54% of solutions bound to plasma, radiochemical purity was more than 95%, and the final volume of 2 ml dosage was stable up to 2 hours after the addition of 99m Tc with a radioactivity of less then 3 mCi. (author)

  16. To Kit or Not to Kit? Evaluating and Implementing Science Materials and Resources

    Science.gov (United States)

    Schiller, Ellen; Melin, Jacque; Bair, Mary

    2016-01-01

    With the release of the "Next Generation Science Standards," many schools are reexamining the science materials they are using. Textbook companies and kit developers are eager to meet the demand for "NGSS"-aligned teaching materials. Teacher may have been asked to serve on a science curriculum committee, or to evaluate current…

  17. Canine and human gastrointestinal stromal tumors display similar mutations in c-KIT exon 11

    International Nuclear Information System (INIS)

    Gregory-Bryson, Emmalena; Bartlett, Elizabeth; Kiupel, Matti; Hayes, Schantel; Yuzbasiyan-Gurkan, Vilma

    2010-01-01

    Gastrointestinal stromal tumors (GISTs) are common mesenchymal neoplasms in the gastrointestinal tract of humans and dogs. Little is known about the pathogenesis of these tumors. This study evaluated the role of c-KIT in canine GISTs; specifically, we investigated activating mutations in exons 8, 9, 11, 13, and 17 of c-KIT and exons 12, 14, and 18 of platelet-derived growth factor receptor, alpha polypeptide (PDGFRA), all of which have been implicated in human GISTs. Seventeen canine GISTs all confirmed to be positive for KIT immunostaining were studied. Exons 8, 9, 11, 13 and 17 of c-KIT and exons 12, 14, and 18 of PDGFRA, were amplified from DNA isolated from formalin-fixed paraffin-embedded samples. Of these seventeen cases, six amplicons of exon 11 of c-KIT showed aberrant bands on gel electrophoresis. Sequencing of these amplicons revealed heterozygous in-frame deletions in six cases. The mutations include two different but overlapping six base pair deletions. Exons 8, 9, 13, and 17 of c-KIT and exons 12, 14, and 18 of PDGFRA had no abnormalities detected by electrophoresis and sequencing did not reveal any mutations, other than synonymous single nucleotide polymorphisms (SNPs) found in exon 11 of c-KIT and exons 12 and 14 of PDGFRA. The deletion mutations detected in canine GISTs are similar to those previously found in the juxtamembrane domain of c-KIT in canine cutaneous mast cell tumors in our laboratory as well as to those reported in human GISTs. Interestingly, none of the other c-KIT or PDGFRA exons showed any abnormalities in our cases. This finding underlines the critical importance of c-KIT in the pathophysiology of canine GISTs. The expression of KIT and the identification of these activating mutations in c-KIT implicate KIT in the pathogenesis of these tumors. Our results indicate that mutations in c-KIT may be of prognostic significance and that targeting KIT may be a rational approach to treatment of these malignant tumors. This study further

  18. FlowGo: An Educational Kit for Fluid Dynamics and Heat Transfer

    Science.gov (United States)

    Guri, Dominic; Portsmore, Merredith; Kemmerling, Erica

    2015-11-01

    The authors have designed and prototyped an educational toolkit that will help middle-school-aged students learn fundamental fluid mechanics and heat transfer concepts in a hands-on play environment. The kit allows kids to build arbitrary flow rigs to solve fluid mechanics and heat transfer challenge problems. Similar kits for other engineering fields, such as structural and electrical engineering, have resulted in pedagogical improvements, particularly in early engineering education, where visual demonstrations have a significant impact. Using the FlowGo kit, students will be able to conduct experiments and develop new design ideas to solve challenge problems such as building plant watering systems or modeling water and sewage reticulation. The toolkit consists of components such as tubes, junctions, and reservoirs that easily snap together via a modular, universal connector. Designed with the Massachusetts K-12 science standards in mind, this kit is intended to be affordable and suitable for classroom use. Results and user feedback from students conducting preliminary tests of the kit will be presented.

  19. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  20. SNF verification requirements imposed through 10 CFR Part 961: Interrelationship with MC ampersand A requirements for the OCRWM safeguards system

    International Nuclear Information System (INIS)

    Slater, N.; Vance, S.

    1994-01-01

    Article VI.B.2 of the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (10 CFR Part 961, Standard Contract) provides that spent nuclear fuel shall be subject to verification prior to acceptance by the Department of Energy. As part of the overall process for scheduling deliveries of spent nuclear fuel, the Standard Contract requires contract holders to submit detailed descriptions of the spent nuclear fuel they intend to deliver. Thus, the provision for verification in the Standard contract allows the Department the opportunity to ensure that the spent nuclear fuel intended for deliver is consistent with the description provided, and that the material is properly loaded, packaged, marked, and labeled. The Department is currently evaluating the verification requirements for spent nuclear fuel that it will establish pursuant to Article VI.B.2 of the Standard Contract. The Department recognizes that there may be significant overlap between these verification requirements and the requirements established for material control and accountability (MC ampersand A). Therefore, the Department may recommend modifications to the process established in the Standard Contract to ensure that the verification and MC ampersand A functions and activities are fully integrated

  1. Epigenetic regulation of cardiac progenitor cells marker c-kit by stromal cell derived factor-1α.

    Directory of Open Access Journals (Sweden)

    Zhongpu Chen

    Full Text Available BACKGROUND: Cardiac progenitor cells (CPCs have been proven suitable for stem cell therapy after myocardial infarction, especially c-kit(+CPCs. CPCs marker c-kit and its ligand, the stem cell factor (SCF, are linked as c-kit/SCF axis, which is associated with the functions of proliferation and differentiation. In our previous study, we found that stromal cell-derived factor-1α (SDF-1α could enhance the expression of c-kit. However, the mechanism is unknown. METHODS AND RESULTS: CPCs were isolated from adult mouse hearts, c-kit(+ and c-kit(- CPCs were separated by magnetic beads. The cells were cultured with SDF-1α and CXCR4-selective antagonist AMD3100, and c-kit expression was measured by qPCR and Western blotting. Results showed that SDF-1α could enhance c-kit expression of c-kit(+CPCs, made c-kit(-CPCs expressing c-kit, and AMD3100 could inhibit the function of SDF-1α. After the intervention of SDF-1α and AMD3100, proliferation and migration of CPCs were measured by CCK-8 and transwell assay. Results showed that SDF-1α could enhance the proliferation and migration of both c-kit(+ and c-kit(- CPCs, and AMD3100 could inhibit these functions. DNA methyltransferase (DNMT mRNA were measured by qPCR, DNMT activity was measured using the DNMT activity assay kit, and DNA methylation was analyzed using Sequenom's MassARRAY platform, after the CPCs were cultured with SDF-1α. The results showed that SDF-1α stimulation inhibited the expression of DNMT1 and DNMT3β, which are critical for the maintenance of regional DNA methylation. Global DNMT activity was also inhibited by SDF-1α. Lastly, SDF-1α treatment led to significant demethylation in both c-kit(+ and c-kit(- CPCs. CONCLUSIONS: SDF-1α combined with CXCR4 could up-regulate c-kit expression of c-kit(+CPCs and make c-kit(-CPCs expressing c-kit, which result in the CPCs proliferation and migration ability improvement, through the inhibition of DNMT1 and DNMT3β expression and global DNMT

  2. Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.

    Science.gov (United States)

    Liu, Jason Yingjie

    2014-11-01

    The effectiveness of a direct quantification assay is essential to the adoption of the combined direct quantification/direct STR workflow. In this paper, the feasibility of using the Quantifiler(®) Trio DNA quantification kit for the direct quantification of forensic casework samples was investigated. Both low-level touch DNA samples and blood samples were collected on PE swabs and quantified directly. The increased sensitivity of the Quantifiler(®) Trio kit enabled the detection of less than 10pg of DNA in unprocessed touch samples and also minimizes the stochastic effect experienced by different targets in the same sample. The DNA quantity information obtained from a direct quantification assay using the Quantifiler(®) Trio kit can also be used to accurately estimate the optimal input DNA quantity for a direct STR amplification reaction. The correlation between the direct quantification results (Quantifiler(®) Trio kit) and the direct STR results (GlobalFiler™ PCR amplification kit(*)) for low-level touch DNA samples indicates that direct quantification using the Quantifiler(®) Trio DNA quantification kit is more reliable than the Quantifiler(®) Duo DNA quantification kit for predicting the STR results of unprocessed touch DNA samples containing less than 10pg of DNA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. [Development and evaluation of a rapid PCR detection kit for Ophiocordyceps sinensis].

    Science.gov (United States)

    Hou, Fei-Xia; Cao, Jing; Wang, Sha-Sha; Wang, Xi; Yuan, Yuan; Peng, Cheng; Wan, De-Guang; Guo, Jin-Lin

    2017-03-01

    Ophiocordyceps sinensis is a valuable traditional Chinese medicine. Due to resource shortage, expensive price and huge market demand, there are many adulterants of O. sinensis in markets. Therefore, it is necessary to establish a rapid and effective method for distinguishing O. sinensis. Based on the species-specific PCR of O. sinensis, this study developed a detection kit by optimizing the components and evaluated the specificity, detection limit, repeatability and shelf life of the kit. The results showed that when the quality of O. sinensis accounted for more than 1/200 of that mixture, it could be detected successfully. Moreover, only O. sinensis could be amplified and glowed bright green fluorescence under ultraviolet light. The kit was still in effect when it was placed at 37 ℃ for three days, which indicated that it was stable and effective for one year stored in 4 ℃. The kit in the same batch under different operation conditions, and in different batch under the same operation conditions gave the same result and accuracy, which showed good repeatability of the kit. It is simple, rapid and accurate to distinguish O. sinensis from its adulterants using the kit, and lays the foundation for commercialization of traditional Chinese medicine fast detection kit. Copyright© by the Chinese Pharmaceutical Association.

  4. Comparison of commercial exosome isolation kits for circulating exosomal microRNA profiling.

    Science.gov (United States)

    Ding, Meng; Wang, Cheng; Lu, Xiaolan; Zhang, Cuiping; Zhou, Zhen; Chen, Xi; Zhang, Chen-Yu; Zen, Ke; Zhang, Chunni

    2018-06-01

    Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. Here, we analyzed the advantages and weaknesses of four commonly used commercial kits for exosomal miRNA profiling and their application to the sample of serum and/or plasma, respectively. NanoSight and Western blotting were conducted to evaluate the efficiency and purity of the isolated exosomes. In our conditions, the size distribution of the isolated particles was appropriate (40-150 nm), and ExoQuick™ Exosome Precipitation Solution (EXQ) generated a relatively high yield of exosomes. Nevertheless, albumin impurity was ubiquitous for all the four kits, and Total Exosome Isolation for serum or plasma (TEI) yielded a relatively pure isolation. We further performed Illumina sequencing combined with RT-qPCR to determine the ability of these kits for miRNA profiling. There was significant correlation of the exosomal miRNA profile and specific miRNAs between kits, but with differences depending on methods. exoRNeasy Serum/Plasma Midi Kit (EXR) and EXQ performed better in the specific exosomal miRNAs recovery. Intraassay CVs for specific miRNA measurement were 0.88-3.82, 1.19-3.77, 0-2.70, and 1.23-9.11% for EXR, TEI, EXQ, and RIBO™ Exosome Isolation Reagent (REI), respectively. In each kit, serum yielded a higher abundance of exosomes and exosomal miRNAs than plasma, yet with more albumin impurity. In conclusion, our data provide some valuable guidance for the methodology of disease biomarker identification of circulation exosomal miRNAs. Graphical abstract Circulating exosomal microRNAs (miRNAs) are valuable biomarker candidates; however, information on the characterization and mutual agreement of commercial kits for circulating exosomal miRNA profiling is scarce. In this study, we compared four commonly used commercially available kits for exosomal mi

  5. Screening of antibiotics residues and development a new kit

    International Nuclear Information System (INIS)

    Elkhaoui, Faycel

    2009-01-01

    The first part of the work was to detect antibiotic residues in animal nutriment: chicken, fish, eggs and milk, by methods of screening: First Test and Delvotest. The second part covered the development of a new kit for the detection of antibiotics residues for honey and competitor kit First Test and saving time and money.

  6. Development of an up-to-date NBC self-aid kit for emergency cases

    International Nuclear Information System (INIS)

    Mueller, Michael; Schmiechen, Katharina

    2009-01-01

    In accordance with alterations of the political and economical settings of Central Europe in the last decades, the characteristics of NBC hazards have changed. Since war appears unlikely, possible new scenarios involve pandemics, chemical transport accidents or distribution of CB warfare agents and radioactive materials by terroristic acts. Meeting this situation requires new protection and self aid equipment for the German civilian disaster relief forces. The German government has reacted to these risks by designing personal protection equipment for the civilian voluntary and professional disaster relief forces. The new NBC self aid kit will be part of this effort. The scientific approach of the project consisted of an updated risk analysis, a questionnaire for the professionals and volunteers involved in disaster management, a thorough evaluation of commercially available kits and single components, final design of the new kit including user instructions, and validation of a prototype kit in a disaster relief exercise. Results of the questionnaire stressed the need for a NBC self aid kit fulfilling the demands of easy handling, use of commercially available components, stability of materials, consumption adapted supply and portable size and weight of the complete kit. The evaluation of international NBC equipment could not identify any current NBC self aid kit which satisfies all needs of the German civilian disaster relief forces. The authors therefore compiled a new kit consisting of commercially available components. The newly developed kit was evaluated in a disaster relief exercise.

  7. Determination of stannous tin in radiopharmaceutical cold kits

    International Nuclear Information System (INIS)

    Farrant, A.J.

    1979-01-01

    Two methods for determining stannous tin in 'cold kits', used for the preparation of Tc-99m labelled radiopharmaceuticals, have been developed. Both are based on the direct titration of the Sn2 in solution. In the first method titration is with N-bromosuccinimide. Of the materials commonly used as cold kits only albumin has been found to interfere with the determination. The second method is a standard iodometric titration in which starch is used as indicator. None of the materials tested interfere with this procedure. The N-bromosuccinimide method is the method of choice as the re-agent, a solid, can be used without prior standardization. Iodine solution must be standardized daily. The paper describes in detail the methods used and gives examples of kits in which the Sn2 levels have been determined using the described procedures

  8. Nuclear track detector kit for use in teaching

    Energy Technology Data Exchange (ETDEWEB)

    Medveczky, L.; Somogyi, G.; Nagy, M.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations.

  9. Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.

    Science.gov (United States)

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2015-12-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.

  10. Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.

    Science.gov (United States)

    Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne

    2014-08-01

    To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.

  11. HDL to verification logic translator

    Science.gov (United States)

    Gambles, J. W.; Windley, P. J.

    1992-01-01

    The increasingly higher number of transistors possible in VLSI circuits compounds the difficulty in insuring correct designs. As the number of possible test cases required to exhaustively simulate a circuit design explodes, a better method is required to confirm the absence of design faults. Formal verification methods provide a way to prove, using logic, that a circuit structure correctly implements its specification. Before verification is accepted by VLSI design engineers, the stand alone verification tools that are in use in the research community must be integrated with the CAD tools used by the designers. One problem facing the acceptance of formal verification into circuit design methodology is that the structural circuit descriptions used by the designers are not appropriate for verification work and those required for verification lack some of the features needed for design. We offer a solution to this dilemma: an automatic translation from the designers' HDL models into definitions for the higher-ordered logic (HOL) verification system. The translated definitions become the low level basis of circuit verification which in turn increases the designer's confidence in the correctness of higher level behavioral models.

  12. KIT RELIABILITY FOR CONTROLLING THE QUALITY OF OILS IN FOOD FRYING

    Directory of Open Access Journals (Sweden)

    Simeon Oloni Kotchoni

    2012-08-01

    Full Text Available In Benin, West Africa, frying is one of the major ways of cooking. However, the chemical composition of the oil used in the food frying process contains unsaturated fatty acids and other by-products that compromise the oil quality making it toxic and often carcinogenic. The aim of this study was to check the reliability of kits in controlling three frying yams oil quality. The food frying was performed using oil in a discontinuous heating period of 15 min followed by three hours of cooling period for two experimental days. The temperature, and the oil chemical samplings were assessed with the kit every thirty minutes. In addition, selected oil chemical characteristics were determined to quantitatively and qualitatively appreciate the chemical modifications during the fast food versus the rapid food processing methods. Our findings indicate that water and volatile chemical compounds vary significantly for the first day of analysis from 0.18% to 1.6% for groundnut oil; from 0.14% to 1.4% for palm oil and from 0.17% to 1.6% for cotton oils. We detected a decrease of iodine index to 25%; 35.31% and 27.78% for groundnut, palm and cotton oils respectively. However, the peroxide index increases to 55.33%; 61.90% and 57.78% for groundnut, palm and cotton oils respectively. The increases of acid and saponification indices were also observed. Under conjugated effect of water temperature contained in the yam and air contact, the chemical characteristics of oil vary with the frying time. Our results reveal concordance consistent data with both the rapid methods and laboratory data set analysis.

  13. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  14. Technetium-99m ceftizoxime kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento [Minas Gerais Univ. Federal, Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Martin-Comin, Josep [Bellvitge Univ., Barcelona (Spain)

    2005-10-15

    The aim of this work was to prepare a kit of {sup 99}m Tc-ceftizoxime ({sup 99m} Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium {sup 99m} Tc pertechnetate solution (Na {sup 99m} Tc O{sub 4-}) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the {sup 99m} Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of {sup 99m} Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for {sup 99}m Tc-CFT were 27.16 {+-} 0.23 and 27.17 {+-} 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 {+-} 0.33 and 29.43 {+-} 0.26, respectively. The results for the biodistribution of {sup 99m} Tc-CFT in infected animals furnished a ratio of 1.97 {+-} 0.31, 2.10 {+-} 0.42 and 2.01 {+-} 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ({sup 99m} Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with {sup 99m} technetium-labeled ceftizoxime for the

  15. Uji Stabilitas Kit Cair Tetrofosmin pada Berbagai Kondisi Penyimpanan

    Directory of Open Access Journals (Sweden)

    Yunilda Yunilda

    2016-09-01

    Full Text Available Tetrofosmin radiopharmaceutical compound that is being developed by PTRR BATAN for use as myocardial perfusion imaging agent and cancer diagnostic agent in nuclear medicine. The aim of this study is observe the stability of this liquid kits after stored in various condition to determine its expire date various condition. The stability test was done of 1 hour, 3 hours, 5 hours and 7 hours after labeling. The radiochemical was determined its radiochemical purity has to be ≥ 90 %. Analysis of radiochemical purity was carried out by separation method which using Sep-Pak C18 cartride. Storage condition of tetrofosmin kit was carried out at various temperatures as in the deep freezer (-800C, freezer (-180C, refrigerator (2-60C and cool box (2-60C. The result showed that the liquid tetrofosmin kits stored in deep freezer, freezer, refrigerator were stable up to 23 months, 8 weeks and 4 days respectively. Simulation of stability  test after stored in a cool box was done by observing the temperature of cool box, and the result showed that the temperature in the cool box was constant as in refrigerator for up to 24 hours. Tetrofosmin which has been labeled with technetium-99m can with stand up 7 hours. It is concluded that expiry date of liquid tetrofosmin kit related with storage temperature, the lower the temperature the longer the expiry date of the kits.

  16. Disposable collection kit for rapid and reliable collection of saliva.

    Science.gov (United States)

    Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek

    2015-01-01

    To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2)  > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.

  17. Low-cost indigenous radiopharmaceutical kits manufacturing capability: a successful work accomplished in Ethiopia

    International Nuclear Information System (INIS)

    Jorge, Y.; Noronha, O.P.D.

    1998-01-01

    Nuclear Medicine Unit at Black Lion Hospital is the only Nuclear Medicine service giving center in the country. We have been importing Radiopharmaceutical-kits for 10 subsequent years costly, with frequent irregularities, only limited Numbers of kits mainly for Liver, Brain, Thyroid and Kidney imagings. Most of the Nuclear Medicine (NM) diagnostic procedures were not undertaken at our unit, because of unavailability of vital Radiopharmaceutical-kits (Rp-kits) in the country since they were not manufactured in the country. In order to solve this long stranding problem of the country persistent efforts were made. The success in Rp-kits manufacturing indigenously has the advantage of disseminating the NM Technology with in the country also. With the continuous efforts made 7 Aqueous-Rp-kits were manufactured successfully in our unit viza-viz: 1) 99m Tc-s-colloid-for Liver imaging. 2) 99m Tc-DTPA-for Brain + Renal imaging. 3) 99m Tc-MDP-for Bone imaging, 4) 99m Tc-Tin (11) pyrophosphate for in-vivo R,B,C, labelling: (For the study of Blood-Pool and Myocardial Infarction), 5) 99m Tc-Tin(11) Gluconate for Brain + Kidney Static imaging. 6) 99m Tc-Tin(11) Phytate for Liver imaging. 7) 99m Tc-TBI for Myocardial perfusion study. Their physico-chemical behaving patterns were studied and the chemical and biological quality control procedures were conducted upon the indigenously produced kits at the National Drug Quality Control center and they were found to be sterile, apyrogenic and non-toxic. The efficiency of the kits was tested in many patients in our unit and found to be effective and reliable. Aqueous kits produced were observed to be as effective and reliable as their lyophilized counterparts with respect to their physico-chemical properties and biospecificity (organ specificity) but possessing short shelf lives unlike lyophilized kits. (author)

  18. 125I-labeled radioimmunoassay kits for progesterone evaluated for use in an in vitro fertilization program

    International Nuclear Information System (INIS)

    Blight, L.F.; White, G.H.

    1983-01-01

    We have evaluated two commercially available 125 I radioimmunoassay kits (Diagnostic Products Corp., DPC; and Radioassay Systems Laboratories, RSL) for measurement of serum or plasma progesterone, to determine their suitability for use in in vitro fertilization programs. Both kits were suitably rapid for program requirements. Results by both were linear with concentration up to 60 nmol/L, and both had acceptable lower detection limits of 0.3 nmol/L. Kit-determined progesterone concentrations (y) for 100 patients' samples correlated well with results by our existing 3H radioimmunoassay method (y . 1.11x + 0.2, r . 0.965 for the DPC kit; y . 1.01x + 1.4, r . 0.974 for the RSL kit). Mean analytical recovery for the RSL kit was 116%, that for the DPC kit, 202%. Within-batch precision, expressed as the mean CV for three concentrations of progesterone, was 6.5% for the RSL kit, and 16.4% for the DPC kit; between-day CV was 8.1% for the RSL kit, 17.7% for the DPC kit. We conclude that the RSL kit provides a rapid, precise, and accurate assay for serum progesterone, suitable for use in a fertilization program, but do not recommend the DPC kit for either this purpose or the more general purpose of tracking menstrual cycles

  19. Determination of Sn in 99mTc Radiopharmaceutical Kits by Polarographic Methods

    International Nuclear Information System (INIS)

    Castro, M.; Cruz, J.; Sanchez, M.

    2009-01-01

    Kits of 99 m Tc radiopharmaceuticals are used in nuclear medicine for diagnosis of different diseases. Sn (II) is one of the essential components in their formulations, which is used for reduction 99 m Tc-pertechnetate in cold kits for on-site preparation 99 m Tc-pertechnetate radiopharmaceuticals. Usually, these cold kits contain different additives (complexing agents, antioxidants, buffers, etc.) and the amount of Sn (II) varies from kit to kit. The determination of Sn in these products is essential in assessing their quality. We report here the development of a new polarographic method for the determination of Sn (II) and total Sn in representative radiopharmaceuticals kits (for the content of Sn and chemical composition) produced at the Center of Isotopes of Cuba (CENTIS). These methods were validated by analysis of variance and recovery techniques. From the results of the validation, the characteristic functions of uncertainties and fits are considered for the established methods, which give the necessary evidences to demonstrate the usefulness of these methods according to the current trends in Analytical Chemistry. This work provides practical results of great importance for CENTIS. After the speciation of Sn in the MAG3 radiopharmaceuticals kit is inferred that the production process is affected by uncontrolled factors that influence in the product stability, which demonstrates the necessity for analytical tools for the characterization of products and processes. (Author) 57 refs.

  20. A New Method to Stabilize c-kit Expression in Reparative Cardiac Mesenchymal Cells

    Directory of Open Access Journals (Sweden)

    Marcin Wysoczynski

    2016-08-01

    Full Text Available Cell therapy improves cardiac function. Few cells have been investigated more extensively or consistently shown to be more effective than c-kit sorted cells; however, c-kit expression is easily lost during passage. Here, our primary goal was to develop an improved method to isolate c-kitpos cells and maintain c-kit expression after passaging. Cardiac mesenchymal cells (CMCs from wild-type mice were selected by polystyrene adherence properties. CMCs adhering within the first hours are referred to as rapidly adherent (RA; CMCs adhering subsequently are dubbed slowly adherent (SA. Both RA and SA CMCs were c-kit sorted. SA CMCs maintained significantly higher c-kit expression than RA cells; SA CMCs also had higher expression endothelial markers. We subsequently tested the relative efficacy of SA versus RA CMCs in the setting of post-infarct adoptive transfer. Two days after coronary occlusion, vehicle, RA CMCs, or SA CMCs were delivered percutaneously with echocardiographic guidance. SA CMCs, but not RA CMCs, significantly improved cardiac function compared to vehicle treatment. Although the mechanism remains to be elucidated, the more pronounced endothelial phenotype of the SA CMCs coupled with the finding of increased vascular density suggest a potential pro-vasculogenic action. This new method of isolating CMCs better preserves c-kit expression during passage. SA CMCs, but not RA CMCs, were effective in reducing cardiac dysfunction. Although c-kit expression was maintained, it is unclear whether maintenance of c-kit expression per se was responsible for improved function, or whether the differential adherence property itself confers a reparative phenotype independently of c-kit.

  1. StochKit2: software for discrete stochastic simulation of biochemical systems with events.

    Science.gov (United States)

    Sanft, Kevin R; Wu, Sheng; Roh, Min; Fu, Jin; Lim, Rone Kwei; Petzold, Linda R

    2011-09-01

    StochKit2 is the first major upgrade of the popular StochKit stochastic simulation software package. StochKit2 provides highly efficient implementations of several variants of Gillespie's stochastic simulation algorithm (SSA), and tau-leaping with automatic step size selection. StochKit2 features include automatic selection of the optimal SSA method based on model properties, event handling, and automatic parallelism on multicore architectures. The underlying structure of the code has been completely updated to provide a flexible framework for extending its functionality. StochKit2 runs on Linux/Unix, Mac OS X and Windows. It is freely available under GPL version 3 and can be downloaded from http://sourceforge.net/projects/stochkit/. petzold@engineering.ucsb.edu.

  2. GossipKit: A Framework of Gossip Protocol Family

    OpenAIRE

    Lin, Shen; Taiani, Francois; Blair, Gordon S.

    2007-01-01

    A large number of gossip protocols have been developed in the last few years to address a wide range of functionalities. So far, however, very few software frameworks have been proposed to ease the development and deployment of these gossip protocols. To address this issue, this paper presents GossipKit, an event-driven framework that provides a generic and extensible architecture for the development of (re)configurable gossip-oriented middleware. GossipKit is based on a generic interaction m...

  3. Development of RIA kits for tumor-markers monitoring

    International Nuclear Information System (INIS)

    Suprarop, P.

    1997-01-01

    All reagents for tumor markers assays are imported from various manufacturers mainly CIS bio international. The average cost of these reagents is ranged from 80-150 bath/test (2-4 dollars test). The screening test for cancers could not be done especially in other regions of Thailand whose budgets and resources are so limited. If the reagents are made locally, many laboratories can perform the tests and use as primary diagnosis, screening or monitor the course of the disease following treatment. In addition, these reagents could help clinicians and give complementary information on the tumor status to improve quality of life in Thailand. Research objectives include: 1. Development of IRMA reagent kits suitable for diagnosing staging and monitoring prostrate and breast cancer. 2. Transfer of technology and reagent kits to relevant laboratories in Thailand. 3. Routine distribution of the reagents kits to the end users

  4. Nuclear track detector kit for use in teaching

    International Nuclear Information System (INIS)

    Medveczky, L.; Somogyi, G.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations. (author)

  5. A nuclear source: a resource kit for teachers

    International Nuclear Information System (INIS)

    Hawkins, Gay.

    1992-01-01

    The aim of this Resource Kit is to provide information, diagrams, overheads and classroom activities, set in an Australian context, to broaden and enrich the teaching of nuclear science from both technical and social science aspects. It has been written to address the the Australian secondary school syllabuses and reflects this in both its format and contents. Emphasis has been given to the applications of nuclear physics to our lives today, from new medical diagnostic techniques to efficient methods of monitoring our own environment. This Resource Kit is a valuable source of information not readily available to teachers from textbooks. It provides a unique opportunity to present the picture in Australia, making us all more aware of Australia's front line in Australia, making us all more aware of Australia's front line role in nuclear research. The kit is meant to be used in conjunction with current textbooks, to complement and enrich them. The kit begins with a review of the many applications of nuclear science in order to provide a broad concrete base to motivate students to discover more of the specific details of the basic discoveries contained in the later sections. Topics such as the Structure of the Atom, which are well documented in textbooks, have been approached in a more creative and less rigorous manner to give teachers a fresh approach to the topic. The kit is divided into 10 separate sections and presented in loose-leaf form to facilitate its use in the classroom. Diagrams are inserted into the text to clarify and enrich descriptions, as well as being provided at the back of each section as black line masters for photocopying and overhead projections. ills., tabs

  6. Tool Kit Helps Digitize Tide Gauge Records

    Science.gov (United States)

    Ullmann, Albin; Pons, Frédéric; Moron, Vincent

    2005-09-01

    The Numérisation des Niveaux d'Eau (NUNIEAU) is an integrated and automated MATLAB computer program tool kit for digitizing, transforming, and validating paper records of sea level variations, called marigrams (Figure 1a), that can cut in half the time required to digitize paper records. This tool kit developed in 2004 by F. Pons is currently obtainable by request from the developer, but will be available online on the IMPLIT (Impact des événements extremes sur les hydro-systèmes du litoral méditerranéen français) Web site in early 2006.

  7. Performance of immunoassay kits for site characterization and remediation

    International Nuclear Information System (INIS)

    Waters, L.C.; Palausky, A.; Counts, R.W.; Jenkins, R.A.

    1995-01-01

    The US Department of Energy (DOE) is supporting efforts to identify, validate and implement the use of effective, low-cost alternatives to currently used analytical methods for environmental management. As part of that program, we have evaluated the performances of a number of immunoassay (IA) kits with specificities for environmental contaminants of concern to the DOE. The studies were done in the laboratory using both spiked and field test samples. The analyte specificity and manufacturers of the kits evaluated were the following: mercury, BioNebraska; polychlorinated biphenyls (PCBs), EnSys and Millipore; petroleum fuel hydrocarbons, Millipore and Ohmicron; and polyaromatic hydrocarbons (PAHs), Ohmicron and Millipore. The kits were used in either a semiquantitative or quantitative format according to the preference of the manufacturers

  8. Energy Education Incentives: Evaluating the Impact of Consumer Energy Kits

    Science.gov (United States)

    Kirby, Sarah D.; Guin, Autumn; Langham, Laura

    2015-01-01

    Measuring the energy and environmental impact of residential energy education efforts is difficult. The E-Conservation residential energy management program uses consumer energy kits to document the impact of energy-efficient improvements. The consumer energy kit provides an incentive for individuals attending energy education workshop, helps…

  9. Indoor Air Quality Tools for Schools Action Kit. Second Edition.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    This kit contains materials to assist a school indoor air quality (IAQ) coordinator in conducting a school IAQ program. The kit contains the following: IAQ coordinator's guide; IAQ coordinator forms; IAQ backgrounder; teacher's classroom checklist; administrative staff checklist; health officer/school nurse checklist; ventilation checklist and…

  10. Validation of low-volume enrichment protocols for detection of Escherichia coli O157 in raw ground beef components, using commercial kits.

    Science.gov (United States)

    Ahmed, Imtiaz; Hughes, Denise; Jenson, Ian; Karalis, Tass

    2009-03-01

    Testing of beef destined for use in ground beef products for the presence of Escherichia coli O157:H7 has become an important cornerstone of control and verification activities within many meat supply chains. Validation of the ability of methods to detect low levels of E. coli O157:H7 is critical to confidence in test systems. Many rapid methods have been validated against standard cultural methods for 25-g samples. In this study, a number of previously validated enrichment broths and commercially available test kits were validated for the detection of low numbers of E. coli O157:H7 in 375-g samples of raw ground beef component matrices using 1 liter of enrichment broth (large-sample:low-volume enrichment protocol). Standard AOAC International methods for 25-g samples in 225 ml of enrichment broth, using the same media, incubation conditions, and test kits, were used as reference methods. No significant differences were detected in the ability of any of the tests to detect low levels of E. coli O157:H7 in samples of raw ground beef components when enriched according to standard or large-sample:low-volume enrichment protocols. The use of large-sample:low-volume enrichment protocols provides cost savings for media and logistical benefits when handling and incubating large numbers of samples.

  11. Documentation for MeshKit - Reactor Geometry (&mesh) Generator

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Rajeev [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    This report gives documentation for using MeshKit’s Reactor Geometry (and mesh) Generator (RGG) GUI and also briefly documents other algorithms and tools available in MeshKit. RGG is a program designed to aid in modeling and meshing of complex/large hexagonal and rectilinear reactor cores. RGG uses Argonne’s SIGMA interfaces, Qt and VTK to produce an intuitive user interface. By integrating a 3D view of the reactor with the meshing tools and combining them into one user interface, RGG streamlines the task of preparing a simulation mesh and enables real-time feedback that reduces accidental scripting mistakes that could waste hours of meshing. RGG interfaces with MeshKit tools to consolidate the meshing process, meaning that going from model to mesh is as easy as a button click. This report is designed to explain RGG v 2.0 interface and provide users with the knowledge and skills to pilot RGG successfully. Brief documentation of MeshKit source code, tools and other algorithms available are also presented for developers to extend and add new algorithms to MeshKit. RGG tools work in serial and parallel and have been used to model complex reactor core models consisting of conical pins, load pads, several thousands of axially varying material properties of instrumentation pins and other interstices meshes.

  12. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  13. KIT polymorphisms and mutations determine responses of neoplastic mast cells to bafetinib (INNO-406).

    Science.gov (United States)

    Peter, Barbara; Hadzijusufovic, Emir; Blatt, Katharina; Gleixner, Karoline V; Pickl, Winfried F; Thaiwong, Tuddow; Yuzbasiyan-Gurkan, Vilma; Willmann, Michael; Valent, Peter

    2010-09-01

    Advanced systemic mastocytosis (SM) is characterized by uncontrolled growth of neoplastic mast cells (MC) and drug resistance. The tyrosine kinase receptor KIT is often mutated and activated and thus contributes to malignant growth of MC. Therefore, KIT-targeting drugs are currently tested for their ability to block growth of malignant MC. We determined the effects of the multikinase inhibitor INNO-406 (bafetinib) on primary neoplastic MC, the canine mastocytoma cell line C2, the human MC leukemia cell line HMC-1.1 bearing the KIT mutant V560G, and HMC-1.2 cells harboring KIT V560G and KIT D816V. INNO-406 was found to inhibit proliferation in HMC-1.1 cells (IC(50): 30-40 nM), but not in HMC-1.2 cells or primary neoplastic cells in patients with KIT D816V-positive SM. In canines, growth-inhibitory effects of INNO-406 were seen in C2 cells (IC(50): 50-100 nM) exhibiting a KIT exon 11 internal tandem-duplication and in primary neoplastic MC harboring wild-type exon 11, whereas no effects were seen in MC exhibiting a polymorphism at amino acid 581 in exon 11. INNO-406 was found to block KIT phosphorylation and expression in HMC-1.1 cells and C2 cells, but not in HMC-1.2 cells, whereas Lyn-phosphorylation was blocked by INNO-406 in all types of MC. In neoplastic MC, the major target of INNO-406 appears to be KIT. Drug responses may depend on the presence and type of KIT mutation. In human MC, the KIT D816V mutant introduces resistance, and in canine mastocytomas, an exon 11 polymorphism may be indicative of resistance against INNO-406.

  14. Quality control for a group of pyrophosphate-Sn kits

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Hernandez, I.; Leyva, R.; Turino, D.

    1994-01-01

    The quality control for a group of Pyrophosphate-Sn kits for labeling with 99 m Tc is carry out at the Isotope Center. A general discussion takes place about the instrumental techniques for the determination of the kit constituent such as ligands, Sn(II), water, etc, as well as the control table for the evaluation of the warranty time. (author). 5 refs, 4 figs

  15. KIT competence center for decommissioning. Innovation and promotion of trainees; Kompetenzzentrum Rueckbau am KIT. Nachwuchsfoerderung und Innovationen fuer den Rueckbau

    Energy Technology Data Exchange (ETDEWEB)

    Gentes, Sascha [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technologie und Management im Baubetrieb

    2016-03-15

    The safe decommissioning of nuclear installations is technically feasible, but is also still a challenge for science, technology and industry. The expertise and know how for decommissioning must be ensured because it will be needed for further decades. Already in 2008 the Karlsruhe Institute of Technology (KIT) had identified this challenge that later emerged through the closure of nuclear power plants in Germany. The KIT opened the professorship Technology and Management of the Decommissioning of Nuclear Installations. In 2014, this section was extended through the dismantling of conventional installations.

  16. Measurement of free thyroxine and free triiodothyronine concentrations by DPC RIA kits

    International Nuclear Information System (INIS)

    Kasagi, Kanji; Kousaka, Tadako; Hatabu, Hiroto; Tokuda, Yasutaka; Iida, Yasuhiro; Konishi, Junji

    1988-01-01

    'DPC RIA' kits for measuring free triiodothyronine (T3) and free thyroxine (T4) were fundamentally and clinically studied. Standard curves for incubation temperature and time were favorable. The present kits yielded satisfactory precision and reproducibility. The upper and lower limits of the normal range for T4 were 0.88 ng/dl and 2.08 ng/dl, respectively. The serum concentration of T4 was 3.91 ng/dl or more for hyperthyroidism and 0.57 ng/dl or less for hypothyroidism, allowing discrimination between the two diseases. For T3, the upper and lower limits of the normal range were 1.45 ng/dl and 3.45 ng/dl, respectively. In pregnant women and patients with decreased or increased levels of thyroxine binding globulin (TBG), the serum T3 concentration lay within the normal range. Low free T4 and T3 levels were found in 22 % and 67 %, respectively, of patients with serious non-thyroidal illness (NTI). There was a good correlation between the present kits and the other commercially available kits. Measurements of free T3 and T4 obtained by ''Amerlex RIA'' kits tended to be lower than those by the present kits in pregnant women and NTI patients with hypoalbuminemia. In view of the simplified procedure, satisfactory precision and reproducibility, and the lack of influences of serum albumin and TBG, the present kits have a potential in routine use. (Namekawa, K.)

  17. A method for online verification of adapted fields using an independent dose monitor

    International Nuclear Information System (INIS)

    Chang Jina; Norrlinger, Bernhard D.; Heaton, Robert K.; Jaffray, David A.; Cho, Young-Bin; Islam, Mohammad K.; Mahon, Robert

    2013-01-01

    Purpose: Clinical implementation of online adaptive radiotherapy requires generation of modified fields and a method of dosimetric verification in a short time. We present a method of treatment field modification to account for patient setup error, and an online method of verification using an independent monitoring system.Methods: The fields are modified by translating each multileaf collimator (MLC) defined aperture in the direction of the patient setup error, and magnifying to account for distance variation to the marked isocentre. A modified version of a previously reported online beam monitoring system, the integral quality monitoring (IQM) system, was investigated for validation of adapted fields. The system consists of a large area ion-chamber with a spatial gradient in electrode separation to provide a spatially sensitive signal for each beam segment, mounted below the MLC, and a calculation algorithm to predict the signal. IMRT plans of ten prostate patients have been modified in response to six randomly chosen setup errors in three orthogonal directions.Results: A total of approximately 49 beams for the modified fields were verified by the IQM system, of which 97% of measured IQM signal agree with the predicted value to within 2%.Conclusions: The modified IQM system was found to be suitable for online verification of adapted treatment fields

  18. An independent verification and validation of the Future Theater Level Model conceptual model

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III; Kruse, K.L.; Martellaro, A.J.; Packard, S.L.; Thomas, B. Jr.; Turley, V.K.

    1994-08-01

    This report describes the methodology and results of independent verification and validation performed on a combat model in its design stage. The combat model is the Future Theater Level Model (FTLM), under development by The Joint Staff/J-8. J-8 has undertaken its development to provide an analysis tool that addresses the uncertainties of combat more directly than previous models and yields more rapid study results. The methodology adopted for this verification and validation consisted of document analyses. Included were detailed examination of the FTLM design documents (at all stages of development), the FTLM Mission Needs Statement, and selected documentation for other theater level combat models. These documents were compared to assess the FTLM as to its design stage, its purpose as an analytical combat model, and its capabilities as specified in the Mission Needs Statement. The conceptual design passed those tests. The recommendations included specific modifications as well as a recommendation for continued development. The methodology is significant because independent verification and validation have not been previously reported as being performed on a combat model in its design stage. The results are significant because The Joint Staff/J-8 will be using the recommendations from this study in determining whether to proceed with develop of the model.

  19. Technetium-99m ceftizoxime kit preparation

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT, with stability and biological activity preserved, able to identify a septic focus (E. coli in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL. After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4- with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli, the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.O objetivo deste trabalho foi preparar um kit de Tc

  20. Likelihood-ratio-based biometric verification

    NARCIS (Netherlands)

    Bazen, A.M.; Veldhuis, Raymond N.J.

    2002-01-01

    This paper presents results on optimal similarity measures for biometric verification based on fixed-length feature vectors. First, we show that the verification of a single user is equivalent to the detection problem, which implies that for single-user verification the likelihood ratio is optimal.

  1. Likelihood Ratio-Based Biometric Verification

    NARCIS (Netherlands)

    Bazen, A.M.; Veldhuis, Raymond N.J.

    The paper presents results on optimal similarity measures for biometric verification based on fixed-length feature vectors. First, we show that the verification of a single user is equivalent to the detection problem, which implies that, for single-user verification, the likelihood ratio is optimal.

  2. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  3. Implementing inquiry-based kits within a professional development school model

    Science.gov (United States)

    Jones, Mark Thomas

    2005-07-01

    Implementation of guided inquiry teaching for the first time carries inherent problems for science teachers. Reform efforts on inquiry-based science teaching are often unsustainable and are not sensitive to teachers' needs and abilities as professionals. Professional development schools are meant to provide a research-based partnership between a public school and a university. These collaborations can provide support for the professional development of teachers. This dissertation reports a study focused on the implementation of inquiry-based science kits within the support of one of these collaborations. The researcher describes the difficulties and successful adaptations experienced by science teachers and how a coteaching model provided support. These types of data are needed in order to develop a bottom-up, sustainable process that will allow teachers to implement inquiry-based science. A qualitative methodology with "researcher as participant" was used in this study of two science teachers during 2002--2003. These two teachers were supported by a coteaching model, which included preservice teachers for each teacher as well as a supervising professor. Data were collected from the researcher's direct observations of coteachers' practice. Data were also collected from interviews and reflective pieces from the coteachers. Triangulation of the data on each teacher's case supported the validity of the findings. Case reports were prepared from these data for each classroom teacher. These case reports were used and cross-case analysis was conducted to search for major themes and findings in the study. Major findings described the hurdles teachers encounter, examples of adaptations observed in the teachers' cases and the supportive interactions with their coteachers while implementing the inquiry-based kits. In addition, the data were used to make recommendations for future training and use of the kits and the coteaching model. Results from this study showed that the

  4. Assessment of six commercial plasma small RNA isolation kits using qRT-PCR and electrophoretic separation

    DEFF Research Database (Denmark)

    Meerson, Ari; Ploug, Thorkil

    2016-01-01

    of specific miRNAs in different samples varied considerably between the tested extraction methods. Of all kits tested, the QIAGEN miRNeasy kits (Mini and Serum/Plasma kits) and the Macherey-Nagel NucleoSpin kit produced the highest RNA yields. The QIAGEN Exo kit produced lesser yields than what could...... be extracted from the UC fraction using the QIAGEN miRNeasy kits and the Macherey-Nagel NucleoSpin kit. Bioanalyzer results showed an average correlation of R2¼0.8 with endogenous miRNA qRT-PCR results, for sample concentrations >40 pg/ml. The levels of the endogenous miRNAs measured in the two volunteer...... samples were compared with those in a larger group of subjects (n¼10) and found to be typical. Our comparison favors the use of the QIAGEN Serum/Plasma kit and the Macherey-Nagel NucleoSpin kit for plasma miRNA applications. Furthermore, extraction of miRNAs from the UC fraction results in higher yield...

  5. From Kitāb al-ḥadā’iq to Kitāb al-dawā’ir: Reconsidering Ibn al-Sīd al-Batalyawsī’s Philosophical Treatise

    Directory of Open Access Journals (Sweden)

    Eliyahu, Ayala

    2015-06-01

    Full Text Available The philosophical treatise known as Kitāb al-ḥadā’iq is generally ascribed to the 12th century Andalusian author Ibn al-Sīd al-Batalyawsī, although this attribution is sometimes contested. This paper offers a new interpretation of the title, textual history, authorship, sources, and literary genre of this treatise, on the basis of new textual evidence, a reexamination of known evidence, and a comparison between the treatise and Batalyawsī’s works. The conclusions of this study are first, that Kitāb al-ḥadā’iq was not the treatise’s original title, and therefore it should be renamed Kitāb al-dawā’ir; second, that Kitāb al-dawā’ir was originally part of (one of the versions of Batalyawsī’s Kitāb al-masā’il; and third, that the textual and stylistic similarities between this treatise and Batalyawsī’s other works prove the authenticity of the treatise’s attribution to Batalyawsī. In addition, new findings regarding Batalyawsī’s use of formulas from the Rasā’il Ikhwān al-Safā, in Kitāb al-dawā’ir and Kitāb al-masā’il provide further evidence for the deep impact of the Ikhwān on Batalyawsī’s thought, as well as for the close connection between Kitāb al-dawā’ir and Kitāb al-masā’il. This connection is further highlighted according to the attribution of both treatises to the genre of questions and answers in Arabic literature. The evidence gathered in this paper supports the claim that Batalyawsī’s Kitāb al-dawā’ir should be seen as an integral part of his literary oeuvre, as well as of Andalusian philosophical literature in general.Generalmente el tratado filosófico conocido como Kitāb al-ḥadā’iq se asocia al autor andalusí del siglo XII Ibn al-Sid al-Batalyawsī, aunque esta atribución ha sido discutida en ocasiones. Este artículo ofrece una nueva interpretación del título, la historia del texto, la autoría, las fuentes e incluso del género literario al que se

  6. Behaviour of mink kits and dams (Mustela vison) in the lactation period

    DEFF Research Database (Denmark)

    Brink, Anne-Line; Jeppesen, Leif Lau

    2005-01-01

    This study describes the development of the behaviour of mink kits and dams from the fourth to the eighth respectively seventh week after delivery. The study is based on scan observations of 72 mink dams and their kits at a conventional Danish mink farm. The kits started eating when they were about...... 30 d old. Drinking started almost 2 wk later. During these 2 wk there was a peak in the licking of saliva from the dam and of the inter-litter agonistic behaviour. A causal relationship between experienced thirst and agonistic behaviour is suggested. The kits' sucking declined to only 5% of the time...... budget in the seventh week and the stereotypy frequency of the dams increased to about 4% of the time budget. It is suggested that some dams are frustrated by the forced cohabitation with their nutritionally independent kits already in the seventh week and that this should be taken into account when...

  7. Comparison of commercial diagnostic kits for placental lactogen radioimmunoassay

    International Nuclear Information System (INIS)

    Pirkl, S.; Kulenda, Z.

    1976-01-01

    The biochemical laboratory compared the following diagnostic kits for HPL determination: Pharmacia (Sweden), Radiochemical Center Amersham (GB), NEN (USA), Hoechst (FRG), applying the following criteria: 1. price, 2. number of analyses for which one kit may be applied, 3. expiration time, 4. speed, i.e., time elapsed from sample delivery to report (dependent on incubation time), 5. laboriousness, 6. reproducibility, 7. compatibility of values obtained by different kits. Alcohol precipitation (Pharmacia, RCC Amersham) appeared to be the most suitable while Dextran coated charcoal (NEN) and Amberlite (Hoechst) were somewhat more complicated, and the Sorin double antibody technique (ultrafiltration and washing of precipitate on filtres was used for separation) appeared to be the most laborious technique. RCC Amersham was ranked first owing to its lower cost as compared with runner-up Pharmacia. (L.O.)

  8. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  9. A 'same day' TSH radioimmunoassay kit with acceptable precision and accuracy

    International Nuclear Information System (INIS)

    Wood, W.G.; Muenchen Univ.

    1980-01-01

    A new 'same-day' TSH-RIA kit has been tested against an 'in-house' TSH-RIA, using incubation schemes of 4, 22 and 23 h. The kit standards were made up in human TSH-free serum and the method used a preincubation step and separation of bound and free antigen using a double antibody method. The correlation between the 'in-house' method and the kit was very good. The results in sera from TRH-test patients, and also from a recovery test with MRC 68/38 in human serum covering the range 0-50 mU/l were good. A comparison of the new kit was made with its precedessor which had protein based standards highlighted the need for standards in human TSH-free serum seen by the poor correlation (r = 0.619, n = 93). (orig.) [de

  10. Effect of planecta and ROSE? on the frequency characteristics of blood pressure-transducer kits

    OpenAIRE

    Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi

    2014-01-01

    Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE?, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and the...

  11. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    Directory of Open Access Journals (Sweden)

    Nie Jing

    2011-05-01

    Full Text Available Abstract Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers.

  12. Analyzing multimodal communication of specialized film knowledge in educational multimedia kits

    DEFF Research Database (Denmark)

    Maier, Carmen Daniela

    of film and TV organized by a German leading art academy. These multimedia kits, Insight Out, are targeted at film and media professionals, teachers and students who want to know how film making and film language will develop in the digital era. In the multimedia kits, the educational and advertising...... discourses are combined across semiotic modes and media when conveying the new knowledge.   Applying a multimodal analytical framework, the paper focuses on the modal ensembles through which new film knowledge is communicated in the multimedia kits through both educational and advertising discourses...

  13. Scalable Techniques for Formal Verification

    CERN Document Server

    Ray, Sandip

    2010-01-01

    This book presents state-of-the-art approaches to formal verification techniques to seamlessly integrate different formal verification methods within a single logical foundation. It should benefit researchers and practitioners looking to get a broad overview of the spectrum of formal verification techniques, as well as approaches to combining such techniques within a single framework. Coverage includes a range of case studies showing how such combination is fruitful in developing a scalable verification methodology for industrial designs. This book outlines both theoretical and practical issue

  14. Architectural Environment: A Resource Kit.

    Science.gov (United States)

    J.B. Speed Art Museum, Louisville, KY.

    There are many ways to approach the investigation of architecture. One can look at structural form, climate and topography, the aesthetics of style and decoration, building function, historical factors, cultural meanings, or technology and techniques associated with construction. This resource kit touches upon a few of these approaches, ranging…

  15. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  16. A national survey of home-based care kits for palliative HIV/AIDS care in South Africa.

    Science.gov (United States)

    Mabude, Z A; Beksinska, M E; Ramkissoon, A; Wood, S; Folsom, M

    2008-09-01

    The objective of this study was to assess home-based care (HBC) kits and programs in South Africa to evaluate the feasibility of scaling up kit production and distribution. South African HBC organizations received structured questionnaires; key informant interviews and a literature review were completed to assess systems for production, distribution and supply of HBC kits. Meetings with stakeholders were held in two Provinces to share and analyze the study findings. The study team distributed questionnaires to 466 organizations and conducted interviews with representatives from 45 organizations, the Provincial Department of Health (DoH) and manufacturers of kits. All identifiable HBC organizations in South Africa were included in the survey. As a result 215 HBC organizations returned questionnaires; including non-governmental organizations (56%), community-based organizations (32%) and organizations affiliated with government health departments. Two types of kits were available: a home kit and a professional kit. The demand for HBC kits exceeded availability, kit contents and availability varied considerably and the supply chain was irregular. Kit production and distribution systems were fragmented. Replenishment of kit items was problematic. End-users are mostly caregivers who have not received adequate training on their use. The study shows that substantial work has been done by HBC organizations in South Africa to respond to the need for palliative care supplies within resource constraints. The growing demand for kits exceeds the supply. There is a need to improve the supply chain management of HBC kits, strengthen referral systems and links between community-based organizations and government departments, expand training opportunities for care givers, and develop monitoring and evaluation systems.

  17. Reviews Toy: Air swimmers Book: Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Book: Physics Experiments for your Bag Book: Quantum Physics for Poets Equipment: SEP colour wheel kit Equipment: SEP colour mixing kit Software: USB DrDAQ App: iHandy Level Equipment: Photonics Explorer kit Web Watch

    Science.gov (United States)

    2012-01-01

    WE RECOMMEND Air swimmers Helium balloon swims like a fish Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Ballistics book hits the spot Physics Experiments for your Bag Handy experiments for your lessons Quantum Physics for Poets Book shows the economic importance of physics SEP colour wheel kit Wheels investigate colour theory SEP colour mixing kit Cheap colour mixing kit uses red, green and blue LEDs iHandy Level iPhone app superbly measures angles Photonics Explorer kit Free optics kit given to schools WORTH A LOOK DrDAQ DrDAQ software gets an upgrade WEB WATCH Websites show range of physics

  18. Studies on quality control of technetium-99m labelling kits

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo

    1987-12-01

    Various experiments for the quality control of Tc-99m labelled radiopharmaceuticals such as Tc-99m-phytate, Tc-99m-MDP, Tc-99m-Tin Colloid, Tc-99m-DISIDA, Tc-99m-DTPA,Tc-99m-DMSA, Tc-99m-Gulcoheptonate, TC-99m-Pyrophosphate, Tc-99m-HSA, and Tc-99m-HAM were carried out. Labelling yield and radiochemical purity of each of the instant labelling kit of KAERI made were determined by means of radiochromatography. Biodistribution in mice and whole body or specific organ imagings of rabbits were also carried out and discussed the relationship between the data of biodistributions and radiochemical purities. Labelling yeilds were above 98% for almost all of the labelling kits. The radio-pharmaceuticals were accumulated at each target organ with moderate specifities. In case of radiochemical purity of above 98%, the biodistribution and gamma imagings were also better. The kits of MDP and DISIDA were stable at least for four moths while the other kits at least eight months. (Author)

  19. Feasibility of fractionating Myoview cold kits for cost reduction

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1999-01-01

    Full text: Myoview is a freeze-dried ethylene diphosphine ligand that upon reconstitution with 99 Tc m -pertechnetate yields a preparation containing the lipophilic cationic myocardial imaging agent 99 Tc m -tetrofosmin (Tf). The aim of this study was to determine the feasibility of fractionating Myoview kits to reduce the cost of the kit, currently A$350 per vial. Myoview vials were reconstituted with N 2 -flushed saline and split into 4 or 5 aliquots of 0.5 ml, then stored at -80 deg C in N 2 -filled vials for up to 3 months. 99 Tc m -Tf was prepared by the addition of varying volumes of 99 Tc m -pertechnetate (1.1 GBq.ml- 1 ) to give a final ligand concentration of 14.4 μg.ml- 1 , followed by a 15 min incubation at room temperature. Radiochemical purity (RCP) was examined at 0, 1, 2 and 3 months post-fractionation. At each time point, RCP was determined at 0,1, 2, 4, 6 and 24 h post-reconstitution. RCP was measured using the thin layer chromatography method according to the manufacturer's instructions. Over the 3 month evaluation period, RCP was maintained at 96.4 ± 1.7% (n = 48) over 24 h at room temperature. Animal biodistribution studies were used to validate the final product from the full cold kit to that from the fractionated kits. In conclusion, these results show that Myoview kits can be successfully fractionated and stored for up to 3 months. The subsequent 99 Tc m -Tf can be used to provide significant cost reductions, especially when only 1 patient dose is required

  20. Gene expression in gastrointestinal stromal tumors is distinguished by KIT genotype and anatomic site.

    Science.gov (United States)

    Antonescu, Cristina R; Viale, Agnes; Sarran, Lisa; Tschernyavsky, Sylvia J; Gonen, Mithat; Segal, Neil H; Maki, Robert G; Socci, Nicholas D; DeMatteo, Ronald P; Besmer, Peter

    2004-05-15

    Gastrointestinal stromal tumors (GISTs) are specific KIT expressing and KIT-signaling driven mesenchymal tumors of the human digestive tract, many of which have KIT-activating mutations. Previous studies have found a relatively homogeneous gene expression profile in GIST, as compared with other histological types of sarcomas. Transcriptional heterogeneity within clinically or molecularly defined subsets of GISTs has not been previously reported. We tested the hypothesis that the gene expression profile in GISTs might be related to KIT genotype and possibly to other clinicopathological factors. An HG-U133A Affymetrix chip (22,000 genes) platform was used to determine the variability of gene expression in 28 KIT-expressing GIST samples from 24 patients. A control group of six intra-abdominal leiomyosarcomas was also included for comparison. Statistical analyses (t tests) were performed to identify discriminatory gene lists among various GIST subgroups. The levels of expression of various GIST subsets were also linked to a modified version of the growth factor/KIT signaling pathway to analyze differences at various steps in signal transduction. Genes involved in KIT signaling were differentially expressed among wild-type and mutant GISTs. High gene expression of potential drug targets, such as VEGF, MCSF, and BCL2 in the wild-type group, and Mesothelin in exon 9 GISTs were found. There was a striking difference in gene expression between stomach and small bowel GISTs. This finding was validated in four separate tumors, two gastric and two intestinal, from a patient with familial GIST with a germ-line KIT W557R substitution. GISTs have heterogeneous gene expression depending on KIT genotype and tumor location, which is seen at both the genomic level and the KIT signaling pathway in particular. These findings may explain their variable clinical behavior and response to therapy.

  1. Concurrent inhibition of kit- and FcepsilonRI-mediated signaling: coordinated suppression of mast cell activation

    DEFF Research Database (Denmark)

    Jensen, Bettina M; Beaven, Michael A; Iwaki, Shoko

    2008-01-01

    Although primarily required for the growth, differentiation, and survival of mast cells, Kit ligand (stem cell factor) is also required for optimal antigen-mediated mast cell activation. Therefore, concurrent inhibition of Kit- and FcepsilonRI-mediated signaling would be an attractive approach...... characterized Kit inhibitor imatinib mesylate (imatinib). In contrast to imatinib, however, hypothemycin also effectively inhibited FcepsilonRI-mediated degranulation and cytokine production in addition to the potentiation of these responses via Kit. The effect of hypothemycin on Kit-mediated responses could...... be explained by its inhibition of Kit kinase activity, whereas the inhibitory effects on FcepsilonRI-dependent signaling were at the level of Btk activation. Because hypothemycin also significantly reduced the mouse passive cutaneous anaphylaxis response in vivo, these data provide proof of principle...

  2. Basic and clinical evaluation of thyroxine radioimmunoassay kit. I. T-4 RIA kit

    Energy Technology Data Exchange (ETDEWEB)

    Bunko, H; Hisada, K [Kanazawa Univ. (Japan). Hospital

    1976-02-01

    The T/sub 4/ RIA kit is based on single antibody radioimmunoassay and utilizes a resin-sponge to separate free T/sub 4/-/sup 125/I from the incubation mixture. The use of the sodium salt of trichloroacetic acid (TBG inhibitor) permits direct radioimmunoassay of T/sub 4/ without a tedious extraction procedure. The T/sub 4/ RIA kit needs only 0.05 ml of patient serum and one hour of incubation to measure T/sub 4/. The TBG inhibitior was equivalent to 5.1 ..mu..g% of T/sub 4/ in displacing radioactive T/sub 4/ from TBG in a CPBA(Res-O-Mat T/sub 4/) system, and the TBG inhibitor volume of 0.5 ml (ten times of serum) was needed to measure a high T/sub 4/ concentration serum. The change of incubation temperature was more affected on the standard curve than that of incubation time. Correlation of the T/sub 4/ value between radioimmunoassay and CPBA in 69 patients was good (r=0.88612, p<0.01) and showed a slightly higher T/sub 4/ value when measured with radioimmunoassay than CPBA (linear regression function: Y=1.17506 + 0.95766X). Correlation of T/sub 4/ between Compu-curve and conventional standard curve was excellent (r=0.9995), but a slight difference was found in both low and high T/sub 4/ concentrations. In euthyroid patients without thyroid diseases, T/sub 4/ concentration was 9.92 +- 2.66 (SD) ..mu..g% and the normal range was between 4.60 and 15.24 ..mu..g%. Reproducibility within assay was 9.9% (CV) and recovery rate was 70% when added 10 ..mu..g of T/sub 4/ and 86% when added 15 ..mu..g% of T/sub 4/. From these results, the authors concluded that radioimmunoassay of serum T/sub 4/ using the T/sub 4/ RIA kit would be a promising one, especially when measuring a large amount of samples per assays.

  3. Can self-verification strivings fully transcend the self-other barrier? Seeking verification of ingroup identities.

    Science.gov (United States)

    Gómez, Angel; Seyle, D Conor; Huici, Carmen; Swann, William B

    2009-12-01

    Recent research has demonstrated self-verification strivings in groups, such that people strive to verify collective identities, which are personal self-views (e.g., "sensitive") associated with group membership (e.g., "women"). Such demonstrations stop short of showing that the desire for self-verification can fully transcend the self-other barrier, as in people working to verify ingroup identities (e.g., "Americans are loud") even when such identities are not self-descriptive ("I am quiet and unassuming"). Five studies focus on such ingroup verification strivings. Results indicate that people prefer to interact with individuals who verify their ingroup identities over those who enhance these identities (Experiments 1-5). Strivings for ingroup identity verification were independent of the extent to which the identities were self-descriptive but were stronger among participants who were highly invested in their ingroup identities, as reflected in high certainty of these identities (Experiments 1-4) and high identification with the group (Experiments 1-5). In addition, whereas past demonstrations of self-verification strivings have been limited to efforts to verify the content of identities (Experiments 1 to 3), the findings also show that they strive to verify the valence of their identities (i.e., the extent to which the identities are valued; Experiments 4 and 5). Self-verification strivings, rather than self-enhancement strivings, appeared to motivate participants' strivings for ingroup identity verification. Links to collective self-verification strivings and social identity theory are discussed.

  4. Mobile Probing Kit

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Sørensen, Lene Tolstrup; Sørensen, J.K.

    2007-01-01

    Mobile Probing Kit is a low tech and low cost methodology for obtaining inspiration and insights into user needs, requirements and ideas in the early phases of a system's development process. The methodology is developed to identify user needs, requirements and ideas among knowledge workers...... characterized as being highly nomadic and thus potential users of mobile and ubiquitous technologies. The methodology has been applied in the 1ST MAGNET Beyond project in order to obtain user needs and requirements in the process of developing pilot services. We report on the initial findings from applying...

  5. NEMO educational kit on micro-optics at the secondary school

    Science.gov (United States)

    Flores-Arias, M. T.; Bao-Varela, Carmen

    2014-07-01

    NEMO was the "Network of Excellence in Micro-Optics" granted in the "Sixth Framework Program" of the European Union. It aimed at providing Europe with a complete Micro-Optics food-chain, by setting up centers for optical modeling and design; measurement and instrumentation; mastering, prototyping and replication; integration and packaging and reliability and standardization. More than 300 researchers from 30 groups in 12 countries participated in the project. One of the objectives of NEMO was to spread excellence and disseminate knowledge on micro-optics and micro-photonics. To convince pupils, already from secondary school level on, about the crucial role of light and micro-optics and the opportunities this combination holds, several partners of NEMO had collaborate to create this Educational Kit. In Spain the partner involved in this aim was the "Microoptics and GRIN Optics Group" at the University of Santiago of Compostela (USC). The educational kits provided to the Secondary School were composed by two plastic cards with the following microoptical element: different kinds of diffractive optical elements or DOES and refractive optical elements or ROEs namely arrays of micro-lenses. The kit also included a DVD with a handbook for performing the experiments as well as a laser pointer source. This kit was distributed free of charge in the countries with partners in NEMO. In particular in Spain was offered to around 200 Secondary School Centers and only 80 answered accepting evaluate the kit.

  6. A critical appraisal of a further three new commercial digoxin radioimmunoassay kits with reference to cross-reacting substances

    International Nuclear Information System (INIS)

    Wood, W.G.; Wachter, C.

    1979-01-01

    A further 3 digoxin radioimmunoassay (RIA) kits have been evaluated for performance and cross-reaction with digitoxin, spironolactone, canrenone and furosemide (Lasix-Hoechst). Effects of serum protein concentrations have also been tested. The kits tested were from the following manufacturers: A) Diagnostic Products Corporation Digoxin RIA Kit. B) Byk-Mallinckrodt SPAC Digoxin Kit. C) Boehringer-Mannheim Digoxin RIA Kit. All kits used a 125 I-labelled tracer. Kit A used a conventional liquid phase system using double-antibody separation for bound and free drug. Kits B and C used a solid-phase antibody coated tube method. All kits showed a lower cross-reaction to digitoxin than quoted by the manufacturer. Cross-reaction to spironolactone (Aldactone - Boehringer-Mannheim) was less than 1.50 nmol/l at a serum concentration of 125 mg/l Aldactone in all 3 kits. The cross-reaction to canrenone was somewhat higher, 5.2 nmol/l 'digoxin' being measured in one kit at a serum canrenone concentration of 125 mg/l. There was no cross-reaction with furosemide in any kit, even at a serum concentration of 5 g/l. The coated-tube assays were affected by serum albumin and globulin concentration changes, one kit showing a difference of over 50% binding in the range 1-20% albumin. The double-antibody kit did not show dependence on the concentration of these proteins. All kits measured digoxin with good reproducibility in the range 0.40-10.0 nmol/l. (orig.) [de

  7. First aid kits for recreational dive boats, what should they contain?

    Science.gov (United States)

    Pye, Jacqueline; Greenhalgh, Trisha

    2010-09-01

    Well-equipped first-aid kits are necessary but not always provided on recreational dive boats. We aimed to review the types of illness and injury likely to be encountered on such boats and inform a content list for such kits. We conducted a 3-round Delphi study by email using a volunteer panel of 18 experts drawn from diving, dive medicine and nursing. In round 1, panellists shared examples of illnesses and injuries they had come across personally. These scenarios were circulated along with findings from a literature review, including existing recommendations. In rounds 2 and 3, the list of kit for dive boats in different settings was iteratively refined through online discussion and feedback. Passengers and crew on recreational dive boats may encounter a range of medical problems from minor injuries to serious accidents and non-dive-related illnesses. Recommended kit varied depending on context and setting (e.g. distance from land, qualifications and experience of crew). Consensus was quickly reached on key first-aid items but experts' views on emergency medicines differed. The study highlights the diversity of medical problems encountered on recreational dive boats. We offer preliminary guidance on the content of suitable first-aid kits and suggest areas for further research. Copyright © 2010 Elsevier Ltd. All rights reserved.

  8. M-COPA suppresses endolysosomal Kit-Akt oncogenic signalling through inhibiting the secretory pathway in neoplastic mast cells.

    Directory of Open Access Journals (Sweden)

    Yasushi Hara

    Full Text Available Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs, acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt pathway and the signal transducer and activator of transcription 5 (STAT5 but only on endolysosomes and on the endoplasmic reticulum (ER, respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide, an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM. Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is

  9. M-COPA suppresses endolysosomal Kit-Akt oncogenic signalling through inhibiting the secretory pathway in neoplastic mast cells.

    Science.gov (United States)

    Hara, Yasushi; Obata, Yuuki; Horikawa, Keita; Tasaki, Yasutaka; Suzuki, Kyohei; Murata, Takatsugu; Shiina, Isamu; Abe, Ryo

    2017-01-01

    Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs), acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt) pathway and the signal transducer and activator of transcription 5 (STAT5) but only on endolysosomes and on the endoplasmic reticulum (ER), respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide), an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM). Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is unable to

  10. Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.

    Science.gov (United States)

    Schou, T M; Malmkvist, J

    2017-09-01

    We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we

  11. Single vial kit formulation for preparation of PET radiopharmaceutical. 68Ga-DOTA-TOC

    International Nuclear Information System (INIS)

    Archana Mukherjee; Usha Pandey; Rubel Chakravarty; Ashutosh Dash; Haladhar Dev Sarma

    2014-01-01

    This paper describes the development of a lyophilized cold kit of DOTA-[Tyr 3 ]-Octreotide (DOTA-TOC) for instant compounding of 68 Ga-DOTA-TOC, suitable for diagnosis of neuroendocrine tumors. The work involved formulation of DOTA-TOC kits, optimization of radiolabeling, quality control of 68 Ga-DOTA-TOC and animal biodistribution studies. The prepared kits enable a reliable method for preparation of 68 Ga-DOTA-TOC of high radiochemical purity and excellent stability. Availability of such kits along with 68 Ge/ 68 Ga generators is expected to stimulate the widespread use of 68 Ga-DOTA-TOC in nuclear medicine practice in developing countries. (author)

  12. Utterance Verification for Text-Dependent Speaker Recognition

    DEFF Research Database (Denmark)

    Kinnunen, Tomi; Sahidullah, Md; Kukanov, Ivan

    2016-01-01

    Text-dependent automatic speaker verification naturally calls for the simultaneous verification of speaker identity and spoken content. These two tasks can be achieved with automatic speaker verification (ASV) and utterance verification (UV) technologies. While both have been addressed previously...

  13. Selling Addiction: A Workshop Kit on Tobacco and Alcohol Advertising. A Media Literacy Workshop Kit.

    Science.gov (United States)

    Barnes, Mary Ellen; And Others

    This kit consists of: (1) a leader's guide; (2) an 18-minute videotape containing three 6-minute discussion starter segments analyzing typical commercials and advertising techniques; (3) a special issue of "Media Values" magazine on the theme "Fatal Attraction: The Selling of Addiction"; (4) an 8-page booklet "Awareness to Action: Media Literacy…

  14. Active Parenting Now: Program Kit.

    Science.gov (United States)

    Popkin, Michael H.

    Based largely on the theories of Alfred Adler and Rudolf Dreikurs, this parent education curriculum is a video-based interactive learning experience that teaches a comprehensive model of parenting to parents of children ages 5 to 12 years. The kit provides parents with the skills needed to help their children develop courage, responsibility, and…

  15. Work and Family Resource Kit.

    Science.gov (United States)

    Women's Bureau (DOL), Washington, DC.

    This kit is designed to help employers understand the range of family needs emerging in the workplace and the numerous options for a company response. An introduction discusses the need for child care services, dependent care problems, and how employers respond and benefit. Sections address the following: selecting the right option in relation to…

  16. INNOVATIVE TECHNOLOGY VERIFICATION REPORT " ...

    Science.gov (United States)

    The RemediAidTm Total Petroleum Hydrocarbon Starter Kit (RemediAidTm kit) developed by CHEMetries, Inc. (CHEMetrics), and AZUR Environmental Ltd was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The purpose of the demonstration was to collect reliable performance and cost data for the RemediAid Tm kit and six other field measurement devices for total petroleum hydrocarbons (TPH) in soil. In addition to assessing ease of device operation, the key objectives of the demonstration included determining the (1) method detection limit, (2) accuracy and precision, (3) effects of interferents and soil moisture content on TPH measurement, (4) sample throughput, and (5) TPH measurement costs for each device. The demonstration involved analysis of both performance evaluation samples and environmental samples collected in five areas contaminated with gasoline, diesel, lubricating oil, or other petroleum products. The performance and cost results for a given field measurement device were compared to those for an off-site laboratory reference method,

  17. 21 CFR 864.9650 - Quality control kit for blood banking reagents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for blood banking reagents... SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a...

  18. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    Science.gov (United States)

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  19. Optimization Of Preparation And Validation Of Hepatitis C Irma Kit

    International Nuclear Information System (INIS)

    Ariyanto, Agus; Wayan, R.S.; Sukiyati, Dj.; Darwati, Siti; Yunita, Fitri; Mondrida, Gina; Sulaiman; Yulianti, Veronika; Setiowati, Sri

    2000-01-01

    Optimization of preparation and validation of hepatitis C IRMA kit have been done. Tracer was prepared by iodination of anti-hlgG with 125 I using Choramin-T and N-Bromosuksinimide as oxidizing agent. Iodinated anti-hlgG was purified using PD-10 and Sephadex G-50 column. Coated bead was prepared by immobilization of antigen HCV recombinant on polystyrene bead. To obtain a good quality of reagent some parameters were optimized i.e.: colim used for purification. To determine the validity of the kit, validation which include comparison study and determination of specificity and sensitivity have been performed. A good quality of tracer has been able to prepared with high yield (74%) and high P/N value (15). The quality of coated bead is also reasonably good (P/N 34.3), and gave a good density and dissociation index (0.335 and 0.99% respectively). Both tracer and coated bead were remain stable after 2 months storage at 4 o C. In comparison with Elisa kit, the specificity and sensitivity of the HCV IRMA kit is reasonably high, 88.6% and 92.3% respectively

  20. [Effect comparison between two ELISA kits in IgG antibody detection of Echinococcus granulosus].

    Science.gov (United States)

    Chu, Yan-Hong; Cai, Yu-Chun; Ai, Lin; Lu, Yan; Zhang, Jia; Chen, Jia-Xu

    2013-06-01

    To compare the effects of two ELISA kits on IgG antibody detection of human Echinococcus granulosus. A Total of 134 sera of patients with echinococcosis, paragonimiasis westermani, clonorchiasis sinensis, schistosomiasis japonica, and cysticercosis cellulosae, and normal persons were detected by two IgG ELISA kits produced by different companies. Furthermore, the specificity, sensitivity and cross reactivity were counted and analyzed statistically. The sensitivity and specificity were extremely high of the two kits as 100.00%. The cross-reactivity rates were 25.00% (paragonimiasis westermani), 26.09% (clonorchiasis sinensis), 10.00% (schistosomiasis japonica), and 87.5% (cysticercosis), respectively, by using the kit produced by the Combined Company in Shenzhen; the cross-reactivity rates were 5.00% (paragonimiasis westermani), 13.04% (clonorchiasis sinensis), 20.00% (schistosomiasis japonica), and 93.75% (cysticercosis) respectively, by using the kit produced by Haitai Company in Zhuhai. In addition, there was a significant difference of Paragonimus westermani detection (P 0.05) between the two kits. Both ELISA kits on IgG antibody detection of human Echinococcus granulosus have the advantages of a high sensitivity, specificity, convenience and high-speed. However, it is also in urgent need to further solve the cross-reactivity of Echinococcus granulosus with other parasites, in order to improve the accuracy of early diagnosis.

  1. iOS Game Development using SpriteKit Framework with Swift Programming Language

    OpenAIRE

    Gurung, Lal

    2016-01-01

    iOS is a mobile operating system for Apple manufactured phones and tablets. Mobile Gaming Industries are growing very fast, and compatibility with iOS is becoming very popular among game developers. The aim of this Bachelor’s thesis was to find the best available game development tools for iOS platform. The 2D game named Lapland was developed using Apple’s own native framework, SpriteKit. The game was written with the SpriteKit programming language. The combination of SpriteKit and Swift...

  2. Sup(99m)Tc(Sn)-sucralfate; development of an instant labelling kit

    International Nuclear Information System (INIS)

    Grouls, R.J.E.; Ackerman, E.W.; Weegh, G. op de

    1988-01-01

    An instant labelling kit for the preparation of 99m Tc(Sn)-sucralfate has been developed containing 500 mg sucralfate and 1 mg SnCl 2 · 2 H 2 O. The labelling yield, in vitro stability and biodistribution indicate (bio)equivalence of 99m Tc(Sn)-sucralfate and 99m Tc(HSA)-sucralfate. The percentages of labelling obtained with the kit during a period of 8 months always exceeded 95%. The preparation kit is inexpensive and the labelling procedure fast and easy. (author)

  3. A Practitioners Perspective on Verification

    Science.gov (United States)

    Steenburgh, R. A.

    2017-12-01

    NOAAs Space Weather Prediction Center offers a wide range of products and services to meet the needs of an equally wide range of customers. A robust verification program is essential to the informed use of model guidance and other tools by both forecasters and end users alike. In this talk, we present current SWPC practices and results, and examine emerging requirements and potential approaches to satisfy them. We explore the varying verification needs of forecasters and end users, as well as the role of subjective and objective verification. Finally, we describe a vehicle used in the meteorological community to unify approaches to model verification and facilitate intercomparison.

  4. Natural Gas Energy Educational Kit.

    Science.gov (United States)

    American Gas Association, Arlington, VA. Educational Services.

    Prepared by energy experts and educators to introduce middle school and high school students to natural gas and its role in our society, this kit is designed to be incorporated into existing science and social studies curricula. The materials and activities focus on the origin, discovery, production, delivery, and use of natural gas. The role of…

  5. Tc99m MDP kits, production and quality control

    International Nuclear Information System (INIS)

    Othman, I.; Yassine, T.; Lababidi, Z.; Kouli, M.

    1992-11-01

    MDP kits for labelling with Tc 99m were locally produced in different conditions, and the conditions for preparation were optimized. The quality control studies showed that the prepared kits were very good quality and comparable with that imported. Radiochemical purities ranged between 95-98% while reduced technetium ranged between 2-3% and free pertechnetate did not exceed 1%. Bioscan and biodistribution studies also showed high localization of Tc 99m in the skeleton of rats and rabbits. (author). 8 refs., 14 tabs

  6. Increasing the flexibility of the LANCE cAMP detection kit.

    Science.gov (United States)

    Hunter, Morag Rose; Glass, Michelle

    2015-01-01

    The detection of cAMP signalling is a common endpoint in the study of G-protein coupled receptors. A number of commercially available kits enable easy detection of cAMP. These kits are based on competition for a cAMP binding site on an antibody or cAMP binding protein and as such have a limited dynamic range. Here, we describe the optimisation of the commercially-available LANCE cAMP detection kit (PerkinElmer) to enable detection in cell lysates. This kit has been designed for use with live cells, with detection reagents applied to cells without wash steps. The standard protocol therefore requires that all assay reagents are compatible with the antibody and the final fluorescent detection stage, limiting the range of assay media and test compounds that can be utilised. The entire experiment must be repeated if cAMP levels fall outside the limited dynamic range. Here we describe a modified protocol that enables the assay to be performed on cell lysates, thereby overcoming these limitations. In this modified protocol, cells are stimulated for a cAMP response in standard media/buffers, washed and then lysed. The cell lysate is then assayed using a modified protocol for the LANCE cAMP detection kit. Samples were tested for stability following a freeze-thaw cycle. The modified LANCE cAMP detection protocol gives a reproducible measurement of cAMP in cell lysate. Lysate samples remain stable when stored at -80°C. Separating the stimulation and detection phases of this cAMP assay allows a vast array of cell stimulation conditions to be tested. The lysate-modified protocol for the LANCE cAMP detection kit therefore increases the flexibility, versatility and convenience of the assay. As samples are insensitive to freeze-thaw, it enables retesting of samples under different dilution conditions to ensure that all samples remain within the dynamic range of the standard curve. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Preparation and quality control of ECD kit

    International Nuclear Information System (INIS)

    Yassin, T.; Dadokh, M.; Almalki, R.

    2005-05-01

    ECD Kit for brain imaging after labeling with technetium 99m was prepared according to an optimum conditions, Each vial contains 1 mg of ECD and 0.155 mg of stannous chloride anhydrous SnCl 2 , 24 mg of Mannitol and 0.5 mg of Na 2 Ca EDTA, The prepared kit showed high quality satisfying the requirements of international pharmacopoeias from the points of physical, chemical, radiochemical and biological purities, and its validity for human injection. And the labeling yield exceeded 95 % with average value of about 97.63 ± 0.89% for 2mCi /2ml radioactivity , This study also showed that each vial content can be labeled with maximum activity of 99m Tc of about 50 mCi (Authors)

  8. Implantação de um kit para comunicação de acidente do trabalho (KIT-CAT como facilitador das ações que envolvem os acidentes com perfurocortantes Implantación de un kit para comunicación de accidente de trabajo (KIT CAT como facilitador de las acciones que involucran los accidentes con perfurocortantes Implementation of a kit for the communication of occupational accidents (KIT CAT as a facilitator for the actions involving puncture cutting accidents

    Directory of Open Access Journals (Sweden)

    Cristina Maria Fernandes Porto

    1999-12-01

    Full Text Available Este trabalho destaca a criação e aplicação na prática profissional, de um Kit para Comunicação de Acidente de Trabalho com perfurocortantes para a Secretaria Municipal da Saúde de Ribeirão Preto, como um instrumento indispensável à prestação de serviços de assistência à saúde dos funcionários das Unidades de Saúde do município. Evidencia a notificação e início da prevenção das doenças ocupacionais, sendo assim, um instrumento extremamente útil quando da ocorrência do acidente. A criação deste Kit possibilitou a retomada de medidas de prevenção dos acidentes ocupacionais, culminando com a mobilização de servidores e chefias na intensificação das ações preventivas.Este trabajo destaca la creación y aplicación en la practica profesional de un KIT para Comunicación de Accidente de Trabajo con perfurocortantes para la Secretaría Municipal de la Salud de Ribeirão Preto, como instrumento indispensable a la prestación de servicios de asistencia a la salud de los funcionarios de las Unidades de Salud del Municipio. Evidencia la notificación y el inicio de la prevención de enfermedades ocupacionales, siendo así, un instrumento extremamente útil cuando de la ocurrencia del accidente. La creación de este KIT, ha posibilitado la retomada de medidas de prevención de los accidentes ocupacionales, culminando con la movilización de servidores y jefes en la intensificación de las acciones preventivas.This paper emphasizes the creation and application of a KIT for the communication of occupational accidents with puncture-cutting objects to the Municipal Health Bureau from the city of Ribeirão Preto. It is an essential instrument for the health care services directed to all the employees of the Health Units. It also evidences the notification and the beginning of the prevention of occupational diseases, being a highly useful instrument whenever any accident occurs. The creation of this KIT enabled the use of

  9. Macroaggregated albumin (MAA) dry kit and its labelling with 99mTc-radionuclide

    International Nuclear Information System (INIS)

    Nurlaila

    1986-01-01

    The preparation of MAA dry kit has been done with specialized technique. The required technique was carried out in the following condition pH 5.0±0.5; heating temperature at was 75±5 o C, ''Nuova II Sybron Thermolyne'' is used for stirring at scale of 7-8 with 0.5 x 2.5 cm magnetic bar. The diameter of the particle obtained is between 30-70um, which is in accordance with the requirements of lung scanning agent. Wet kit of MAA was dried with feeze dryer. Dry kit of MAA was sterilized by irradiation using Co-60. The sterilization dose of 2.5 Mrad indicated no viable count of bacteria in the media after being incubated for 7-14 days. Labelling efficiencies of MAA dry kit before and after sterilization were 98.97% ± 0.20 and 96.77% ± 2.91 respectively. Labelling efficiency of labelled compound was determined by paper chromatography using methanol 85% as solvent. Stability of MAA dry kit was regularly determined by analysing the labelling efficiency. Dry kit MAA which was stored at room temperature (20-25 o C) and refrigerated temperature (2-4 o C) for two months still indicated chemical purity more than 95%. (author). 7 refs

  10. 76 FR 51037 - Determination That Halflytely and Bisacodyl Tablets Bowel Prep Kit (Containing Two Bisacodyl...

    Science.gov (United States)

    2011-08-17

    ... determined that Halflytely and Bisacodyl Tablets Bowel Prep Kit (polyethylene glycol (PEG) 3350, sodium... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution... that the Agency determine whether Halflytely and Bisacodyl Tablets Bowel Prep Kit (PEG- 3350, sodium...

  11. Using the Planetary Science Institute’s Meteorite Mini-Kits to Address the Nature of Science

    Science.gov (United States)

    Lebofsky, Larry A.; Cañizo, Thea L.; Buxner, Sanlyn

    2014-11-01

    Hands-on learning allows students to understand science concepts by directly observing and experiencing the topics they are studying. The Planetary Science Institute (PSI) has created instructional rock kits that have been introduced to elementary and middle school teachers in Tucson, in our professional development workshops. PSI provides teachers with supporting material and training so that they can use the kits as tools for students’ hands-on learning. Use of these kits provides an important experience with natural materials that is essential to instruction in Earth and Space Science. With a stronger knowledge of science content and of how science is actually conducted, the workshops and kits have instilled greater confidence in teachers’ ability to teach science content. The Next Generation Science Standards (NGSS) Performance Expectations includes: “What makes up our solar system?” NGSS emphasizes the Crosscutting Concepts—Patterns Scale, Portion, and Quantity; and Systems and System Models. NGSS also states that the Nature of Science (NOS) should be an “essential part” of science education. NOS topics include understanding that scientific investigations use a variety of methods, that scientific knowledge is based on empirical evidence, that scientific explanations are open to revision in light of new evidence, and an understanding of the nature of scientific models.Addressing a need expressed by teachers for borrowing kits less expensive than our $2000 option, we created a Meteorite Mini-Kit. Each Mini-Kit contains eight rocks: an iron-bearing chondrite, a sliced chondrite (showing iron and chondrules), a tektite, a common Tucson rock, a river-polished rock, pumice, a small iron, and a rounded obsidian rock (false tektite). Also included in the Mini-Kits are magnets and a magnifier. The kits cost $40 to $50, depending on the sizes of the chondrites. A teacher can check out a classroom set of these which contains either 10 or 20 Mini-Kits. Each

  12. Nuclear disarmament verification

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1993-01-01

    Arms control treaties, unilateral actions, and cooperative activities -- reflecting the defusing of East-West tensions -- are causing nuclear weapons to be disarmed and dismantled worldwide. In order to provide for future reductions and to build confidence in the permanency of this disarmament, verification procedures and technologies would play an important role. This paper outlines arms-control objectives, treaty organization, and actions that could be undertaken. For the purposes of this Workshop on Verification, nuclear disarmament has been divided into five topical subareas: Converting nuclear-weapons production complexes, Eliminating and monitoring nuclear-weapons delivery systems, Disabling and destroying nuclear warheads, Demilitarizing or non-military utilization of special nuclear materials, and Inhibiting nuclear arms in non-nuclear-weapons states. This paper concludes with an overview of potential methods for verification

  13. Verification Account Management System (VAMS)

    Data.gov (United States)

    Social Security Administration — The Verification Account Management System (VAMS) is the centralized location for maintaining SSA's verification and data exchange accounts. VAMS account management...

  14. Combined radioimmunoassay of HBs-antigen and anti-HBs using the Biotest combRIA-Au kit

    International Nuclear Information System (INIS)

    Kselikova, M.; Novak, J.; Urbankova, J.

    1979-01-01

    Hepatitis B antigen and antibody were determined simultaneously by radioimmunoassay using the Biotest combRIA-Au kit. The results in determining antigens and antibodies in sera with a known content of these substances by this kit nearly equal those of isolated determinations of antigen by the Abbott AUSRIA II-125 kit, and of antibody by the Abbott AUSAB kit, resp., except for a negligible number of sera with a very low content of either antigen or antibody. (author)

  15. Radioimmunoassay of serum myoglobin: evaluation and modification of a commercial kit and assessment of its usefulness for detecting acute myocardial infarction

    International Nuclear Information System (INIS)

    Kubasik, N.P.; Guiney, W.; Warren, K.; D'Souza, J.P.; Sine, H.E.; Brody, B.B.

    1978-01-01

    We evaluated a modified procedure for a commercially available myoglobin radioimmunoassay kit (Nuclear Medical Systems). Within-run and run-to-run precision was acceptable. Normal ranges were established and parallelism studies performed. Clinical usefulness was assessed in 100 consecutive patients admitted to our coronary-care facility. The determinations were done daily, along with creatine kinase and its isoenzymes, and lactate dehydrogenase and its isoenzymes. Fifty of the 100 patients ultimately were shown to have had acute myocardial infarction. Myoglobinemia was present in most of the patients with acute myocardial infarction, but information on its presence was less useful clinically than was detection of creatine kinase isoenzyme MB

  16. Quantum money with classical verification

    Energy Technology Data Exchange (ETDEWEB)

    Gavinsky, Dmitry [NEC Laboratories America, Princeton, NJ (United States)

    2014-12-04

    We propose and construct a quantum money scheme that allows verification through classical communication with a bank. This is the first demonstration that a secure quantum money scheme exists that does not require quantum communication for coin verification. Our scheme is secure against adaptive adversaries - this property is not directly related to the possibility of classical verification, nevertheless none of the earlier quantum money constructions is known to possess it.

  17. Quantum money with classical verification

    International Nuclear Information System (INIS)

    Gavinsky, Dmitry

    2014-01-01

    We propose and construct a quantum money scheme that allows verification through classical communication with a bank. This is the first demonstration that a secure quantum money scheme exists that does not require quantum communication for coin verification. Our scheme is secure against adaptive adversaries - this property is not directly related to the possibility of classical verification, nevertheless none of the earlier quantum money constructions is known to possess it

  18. Hematopoietic Kit Deficiency, rather than Lack of Mast Cells, Protects Mice from Obesity and Insulin Resistance.

    Science.gov (United States)

    Gutierrez, Dario A; Muralidhar, Sathya; Feyerabend, Thorsten B; Herzig, Stephan; Rodewald, Hans-Reimer

    2015-05-05

    Obesity, insulin resistance, and related pathologies are associated with immune-mediated chronic inflammation. Kit mutant mice are protected from diet-induced obesity and associated co-morbidities, and this phenotype has previously been attributed to their lack of mast cells. We performed a comprehensive metabolic analysis of Kit-dependent Kit(W/Wv) and Kit-independent Cpa3(Cre/+) mast-cell-deficient mouse strains, employing diet-induced or genetic (Lep(Ob/Ob) background) models of obesity. Our results show that mast cell deficiency, in the absence of Kit mutations, plays no role in the regulation of weight gain or insulin resistance. Moreover, we provide evidence that the metabolic phenotype observed in Kit mutant mice, while independent of mast cells, is immune regulated. Our data underscore the value of definitive mast cell deficiency models to conclusively test the involvement of this enigmatic cell in immune-mediated pathologies and identify Kit as a key hematopoietic factor in the pathogenesis of metabolic syndrome. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Explanatory chapter: how plasmid preparation kits work.

    Science.gov (United States)

    Koontz, Laura

    2013-01-01

    To isolate plasmid DNA from bacteria using a commercial plasmid miniprep kit (if interested, compare this protocol with Isolation of plasmid DNA from bacteria). Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Determination of triiodothyronine using RIA-Mat T3 kit

    International Nuclear Information System (INIS)

    Hara, Masao

    1975-01-01

    A RIA-Mat T 3 kit was used for an in vitro measurement of triiodothyronine in serum. A resin strip was utilized to absorb free triiodothyronine after the serum was incubated with antibody against triiodothyronine. This test was easy to manipulate and the reproducibility test with same sera, dilution test, and recovery test were also satisfactory. The normal range of triiodothyronine determined with this test kit was 119 +- 40 ng/dl using 50 test sera. Ninety sera with various thyroid diseases were also determined. (auth.)

  1. Android: Call C Functions with the Native Development Kit (NDK)

    Science.gov (United States)

    2016-09-01

    from a Java application. 15. SUBJECT TERMS Android , NDK, Native Development Kit, C callable, Java Native Interface, JNI, Java, C/C++ 16. SECURITY ...ARL-TN-0782 ● SEP 2016 US Army Research Laboratory Android : Call C Functions with the Native Development Kit (NDK) by Hao Q...Do not return it to the originator. ARL-TN-0782 ● SEP 2016 US Army Research Laboratory Android : Call C Functions with the Native

  2. Particularities of Verification Processes for Distributed Informatics Applications

    Directory of Open Access Journals (Sweden)

    Ion IVAN

    2013-01-01

    Full Text Available This paper presents distributed informatics applications and characteristics of their development cycle. It defines the concept of verification and there are identified the differences from software testing. Particularities of the software testing and software verification processes are described. The verification steps and necessary conditions are presented and there are established influence factors of quality verification. Software optimality verification is analyzed and some metrics are defined for the verification process.

  3. 2MASS Catalog Server Kit Version 2.1

    Science.gov (United States)

    Yamauchi, C.

    2013-10-01

    The 2MASS Catalog Server Kit is open source software for use in easily constructing a high performance search server for important astronomical catalogs. This software utilizes the open source RDBMS PostgreSQL, therefore, any users can setup the database on their local computers by following step-by-step installation guide. The kit provides highly optimized stored functions for positional searchs similar to SDSS SkyServer. Together with these, the powerful SQL environment of PostgreSQL will meet various user's demands. We released 2MASS Catalog Server Kit version 2.1 in 2012 May, which supports the latest WISE All-Sky catalog (563,921,584 rows) and 9 major all-sky catalogs. Local databases are often indispensable for observatories with unstable or narrow-band networks or severe use, such as retrieving large numbers of records within a small period of time. This software is the best for such purposes, and increasing supported catalogs and improvements of version 2.1 can cover a wider range of applications including advanced calibration system, scientific studies using complicated SQL queries, etc. Official page: http://www.ir.isas.jaxa.jp/~cyamauch/2masskit/

  4. Nuclear test ban verification

    International Nuclear Information System (INIS)

    Chun, Kin-Yip

    1991-07-01

    This report describes verification and its rationale, the basic tasks of seismic verification, the physical basis for earthquake/explosion source discrimination and explosion yield determination, the technical problems pertaining to seismic monitoring of underground nuclear tests, the basic problem-solving strategy deployed by the forensic seismology resarch team at the University of Toronto, and the scientific significance of the team's research. The research carried out at the Univeristy of Toronto has two components: teleseismic verification using P wave recordings from the Yellowknife Seismic Array (YKA), and regional (close-in) verification using high-frequency L g and P n recordings from the Eastern Canada Telemetered Network. Major differences have been found in P was attenuation among the propagation paths connecting the YKA listening post with seven active nuclear explosion testing areas in the world. Significant revisions have been made to previously published P wave attenuation results, leading to more interpretable nuclear explosion source functions. (11 refs., 12 figs.)

  5. Pharmacologic and toxicologic properties of lyophilic extract Achillea setacea Waldst. et Kit.

    Directory of Open Access Journals (Sweden)

    G. P. Smoylovska

    2017-12-01

    Full Text Available Infusions based on Achillea setacea Waldst. et Kit. are traditionally used as antiinflammatory, hepatic, appetizing, spasmolytic agents, they are used as well in hemorrhages of different etiology, thrombophlebitis and varicose ulcers. Diverse pharmacologic properties are due to the presence of essential oils, proazulene, sesquiterpenic lactones, hydroxycinnamomic acids, flavonoids, vitamin K1 in medicinal raw materials. In using infusion phylloquinone, ascorbinic acid, flavonoids, hydroxycinnamomic acids, Calcium salts, tannins, achileine contribute to regulation of blood coagulation. It is very timely to assess hemostatic activity for lyophilic plant extracts which are perfectly soluble in water and have high biologic availability. The aim of research is to assess the degree of acute toxicity and hemostatic activity for lyophilic extract of herb Achillea setacea Waldst. et Kit. Materials and methods. Lyophilic extracts based on infusion of herb Achillea setacea Waldst. et Kit. obtained by dry sublimation have been used for the research. Lyophilic extracts obtained have been standardized for available vitamin K1 and have been studied for acute toxicity and hemostatic activity. Studying blood coagulation system has been carried out in animals with experimental toxic hepatitis for the following indices: blood coagulation time, prothrombin time, fibrin concentration in the blood. Results. Lyophilic extract based on Achillea setacea Waldst. et Kit. is friable amorphous light yellow mass with bitter taste, containing phylloquinone in concentration 5.79 ± 0.05 %. When studying acute toxicity median lethal dose for lyophilic extracts of Achillea setacea Waldst. et Kit. was above 2000 mg/ml (practically nontoxic ones. Course therapy of extract Achillea setacea Waldst. et Kit. and solution of “Vikasol” for animals with toxic hepatitis led to decreasing hypocoagulation: decreasing prothrombin time and clotting time, increasing fibrin concentration in

  6. Validation of the AmpFlSTR« SEfiler Plus(TM) PCR Amplification kit for forensic STR analysis

    DEFF Research Database (Denmark)

    Fredslund, Stine Frisk; Mogensen, Helle Smidt; Morling, Niels

    2009-01-01

    Validation of the AmpFlSTR« SEfiler Plus(TM) PCR Amplification kit with 29 and 30 PCR cycles for forensic STR analysis demonstrated that the kit had fewer artefacts than the AmpFlSTR« SGM Plus(TM) kit (28 PCR cycles). The SEfiler Plus kit was more sensitive and devoid of colour artefacts, but sho......, but showed more stutters, drop-ins, drop-outs and allelic imbalances...

  7. The KIT-Split in South African English: A critical review | Bekker ...

    African Journals Online (AJOL)

    While the lack of full complementation and the presence of some minimal pairs in SAfE KIT was confirmed by and continued to attract the attention of some later commentators (e.g., Lass and Wright 1985, Taylor 1991), the meaning of the term 'KIT-Split' has, in the meantime, been tacitly reformulated to refer solely to the ...

  8. Profiled Deck Composite Slab Strength Verification: A Review

    Directory of Open Access Journals (Sweden)

    K. Mohammed

    2017-12-01

    Full Text Available The purpose of this article is to present an overview on alternate profiled deck composite slab (PDCS strength verification devoid of the expensive and complex laboratory procedures in establishing its longitudinal shear capacity. Despite the several deterministic research findings leading to the development of proposals and modifications on the complex shear characteristics of PDCS that defines its strength behaviour, the laboratory performance testing stands to be the only accurate means for the PDCS strength assessment. The issue is critical and warrants much further thoughts from different perspective other than the deterministic approach that are rather expensive and time consuming. Hence, the development of a rational-based numerical test load function from longitudinal shear capacity consideration is a necessity in augmenting the previous futile attempts for strength determination of PDCS devoid of the costlier and expensive laboratory procedure.

  9. Overestimation of the 25(OH)D serum concentration with the automated IDS EIA kit.

    Science.gov (United States)

    Cavalier, Etienne; Huberty, Véronique; Cormier, Catherine; Souberbielle, Jean-Claude

    2011-02-01

    We have recently observed an increasing number of patients presenting very high serum levels of 25-hydroxyvitamin D [25(OH)D] (> 150 ng/mL), which, in all cases, had been measured with the IDS EIA kit adapted on different "open" automated platforms. We performed a comparison between the IDS EIA kit adapted on two different "open"automated platforms and the DiaSorin RIA. We found a systematic bias (higher levels with the IDS EIA kit) for concentrations more than 50-60 ng/mL that was less obvious when the IDS EIA was used in its manual procedure. We thus suggest to use the IDS EIA kit in its manual procedure rather than to adapt it on an automated platform, and to interpret cautiously a 25(OH)D greater than 100 ng/mL with this kit. Copyright © 2011 American Society for Bone and Mineral Research.

  10. KIT(D816V) Induces SRC-Mediated Tyrosine Phosphorylation of MITF and Altered Transcription Program in Melanoma

    DEFF Research Database (Denmark)

    Phung, Bengt; Kazi, Julhash U; Lundby, Alicia

    2017-01-01

    The oncogenic D816V mutation of the KIT receptor is well characterized in systemic mastocytosis and acute myeloid leukemia. Although KIT(D816V) has been found in melanoma, its function and involvement in this malignancy is not understood. Here we show that KIT(D816V) induces tyrosine phosphorylat......The oncogenic D816V mutation of the KIT receptor is well characterized in systemic mastocytosis and acute myeloid leukemia. Although KIT(D816V) has been found in melanoma, its function and involvement in this malignancy is not understood. Here we show that KIT(D816V) induces tyrosine.......Implications: This study demonstrates that an oncogenic tyrosine kinase mutant, KIT(D816V), can alter the transcriptional program of the transcription factor MITF in melanoma Mol Cancer Res; 15(9); 1265-74. ©2017 AACR....

  11. Java bytecode verification via static single assignment form

    DEFF Research Database (Denmark)

    Gal, Andreas; Probst, Christian W.; Franz, Michael

    2008-01-01

    Java Virtual Machines (JVMs) traditionally perform bytecode verification by way of an iterative data-flow analysis. Bytecode verification is necessary to ensure type safety because temporary variables in the JVM are not statically typed. We present an alternative verification mechanism that trans......Java Virtual Machines (JVMs) traditionally perform bytecode verification by way of an iterative data-flow analysis. Bytecode verification is necessary to ensure type safety because temporary variables in the JVM are not statically typed. We present an alternative verification mechanism...

  12. Evaluation of the Ramco kit for serum ferritin assay

    Energy Technology Data Exchange (ETDEWEB)

    Dempster, W S; Knight, G J [Red Cross War Memorial Children' s Hospital, Cape Town (South Africa). Department of Paediatrics and Child Health; Jacobs, P [Cape Town Univ. (South Africa). Dept. of Haematology

    1979-12-22

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6..mu..g/l to greater than 2 000 ..mu..g/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice.

  13. Growth control of genetically modified cells using an antibody/c-Kit chimera.

    Science.gov (United States)

    Kaneko, Etsuji; Kawahara, Masahiro; Ueda, Hiroshi; Nagamune, Teruyuki

    2012-05-01

    Gene therapy has been regarded as an innovative potential treatment against serious congenital diseases. However, applications of gene therapy remain limited, partly because its clinical success depends on therapeutic gene-transduced cells acquiring a proliferative advantage. To address this problem, we have developed the antigen-mediated genetically modified cell amplification (AMEGA) system, which uses chimeric receptors to enable the selective proliferation of gene-transduced cells. In this report, we describe mimicry of c-Kit signaling and its application to the AMEGA system. We created an antibody/c-Kit chimera in which the extracellular domain of c-Kit is replaced with an anti-fluorescein single-chain Fv antibody fragment and the extracellular D2 domain of the erythropoietin receptor. A genetically modified mouse pro-B cell line carrying this chimera showed selective expansion in the presence of fluorescein-conjugated BSA (BSA-FL) as a growth inducer. By further engineering the transmembrane domain of the chimera to reduce interchain interaction we attained stricter ligand-dependency. Since c-Kit is an important molecule in the expansion of hematopoietic stem cells (HSCs), this antibody/c-Kit chimera could be a promising tool for gene therapy targeting HSCs. Copyright © 2011 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. Increasing Flight Software Reuse with OpenSatKit

    Science.gov (United States)

    McComas, David C.

    2018-01-01

    In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospace's command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for users to extend the FSW functionality to meet their

  15. Comparison of DNA extraction kits for detection of Burkholderia pseudomallei in spiked human whole blood using real-time PCR.

    Directory of Open Access Journals (Sweden)

    Nicole L Podnecky

    Full Text Available Burkholderia pseudomallei, the etiologic agent of melioidosis, is endemic in northern Australia and Southeast Asia and can cause severe septicemia that may lead to death in 20% to 50% of cases. Rapid detection of B. pseudomallei infection is crucial for timely treatment of septic patients. This study evaluated seven commercially available DNA extraction kits to determine the relative recovery of B. pseudomallei DNA from spiked EDTA-containing human whole blood. The evaluation included three manual kits: the QIAamp DNA Mini kit, the QIAamp DNA Blood Mini kit, and the High Pure PCR Template Preparation kit; and four automated systems: the MagNAPure LC using the DNA Isolation Kit I, the MagNAPure Compact using the Nucleic Acid Isolation Kit I, and the QIAcube using the QIAamp DNA Mini kit and the QIAamp DNA Blood Mini kit. Detection of B. pseudomallei DNA extracted by each kit was performed using the B. pseudomallei specific type III secretion real-time PCR (TTS1 assay. Crossing threshold (C T values were used to compare the limit of detection and reproducibility of each kit. This study also compared the DNA concentrations and DNA purity yielded for each kit. The following kits consistently yielded DNA that produced a detectable signal from blood spiked with 5.5×10(4 colony forming units per mL: the High Pure PCR Template Preparation, QIAamp DNA Mini, MagNA Pure Compact, and the QIAcube running the QIAamp DNA Mini and QIAamp DNA Blood Mini kits. The High Pure PCR Template Preparation kit yielded the lowest limit of detection with spiked blood, but when this kit was used with blood from patients with confirmed cases of melioidosis, the bacteria was not reliably detected indicating blood may not be an optimal specimen.

  16. Molecular Characterization of PDGFR-α/PDGF-A and c-KIT/SCF in Gliosarcomas

    Directory of Open Access Journals (Sweden)

    Rui M. Reis

    2005-01-01

    Full Text Available Gliosarcomas are rare and poorly characterized malignant brain tumors that exhibit a biphasic tissue pattern with areas of gliomatous and sarcomatous differentiation. These tumors are histological variants of glioblastoma, displaying a similar genetic profile and dismal prognosis. Up-regulation of PDGFR subfamily of tyrosine kinase members, PDGFR-α and c-Kit, and their intracellular effectors RAS/RAF/MAPK has a crucial role in the cancer development. In addition, signal transduction mediated by activating mutations of c-Kit and PDGFR can be effectively blocked by specific tyrosine kinase inhibitors, such as Imatinib mesylate. The aim of this study was to characterize the molecular alterations of PDGFR signaling in gliosarcomas. Six cases were analyzed by immunohistochemistry for the expression of PDGFR-α, c-Kit and their ligands PDGF-A and SCF, respectively. The cases were further evaluated for the presence of activating mutations of PDGFR-α (exons 12 and 18 and c-kit (exons 9, 11, 13, and 17, as well as B-RAF (exons 11 and 15. Expression of PDGF-A was found in all cases and co-expression of PDGFR-α was observed in three cases. Four cases showed expression of SCF, and c-Kit was observed only in one case that also expressed SCF. Generally, immunoreaction predominates in the glial component. The mutational analysis of PDGFR-α showed the presence of an IVS17-50insT intronic insertion in two cases, one of them also with a 2472C > T silent mutation; this silent mutation was also found in another case. Glioma cell line analysis of IVS17-50insT insertion showed no influence on PDGFR-α gene splicing. No mutations were detected in c-kit and B-RAF oncogenes. Our Results indicate that activating mutations of PDGFR-α, c-kit and B-RAF are absent in gliosarcomas. Nevertheless, the presence of a PDGFR-a/PDGFA and c-Kit/SCF autocrine/paracrine stimulation loop in a proportion of cases, supports the potential role of specific tyrosine kinase inhibitors in

  17. Internet-based dimensional verification system for reverse engineering processes

    International Nuclear Information System (INIS)

    Song, In Ho; Kim, Kyung Don; Chung, Sung Chong

    2008-01-01

    This paper proposes a design methodology for a Web-based collaborative system applicable to reverse engineering processes in a distributed environment. By using the developed system, design reviewers of new products are able to confirm geometric shapes, inspect dimensional information of products through measured point data, and exchange views with other design reviewers on the Web. In addition, it is applicable to verifying accuracy of production processes by manufacturing engineers. Functional requirements for designing this Web-based dimensional verification system are described in this paper. ActiveX-server architecture and OpenGL plug-in methods using ActiveX controls realize the proposed system. In the developed system, visualization and dimensional inspection of the measured point data are done directly on the Web: conversion of the point data into a CAD file or a VRML form is unnecessary. Dimensional verification results and design modification ideas are uploaded to markups and/or XML files during collaboration processes. Collaborators review the markup results created by others to produce a good design result on the Web. The use of XML files allows information sharing on the Web to be independent of the platform of the developed system. It is possible to diversify the information sharing capability among design collaborators. Validity and effectiveness of the developed system has been confirmed by case studies

  18. Internet-based dimensional verification system for reverse engineering processes

    Energy Technology Data Exchange (ETDEWEB)

    Song, In Ho [Ajou University, Suwon (Korea, Republic of); Kim, Kyung Don [Small Business Corporation, Suwon (Korea, Republic of); Chung, Sung Chong [Hanyang University, Seoul (Korea, Republic of)

    2008-07-15

    This paper proposes a design methodology for a Web-based collaborative system applicable to reverse engineering processes in a distributed environment. By using the developed system, design reviewers of new products are able to confirm geometric shapes, inspect dimensional information of products through measured point data, and exchange views with other design reviewers on the Web. In addition, it is applicable to verifying accuracy of production processes by manufacturing engineers. Functional requirements for designing this Web-based dimensional verification system are described in this paper. ActiveX-server architecture and OpenGL plug-in methods using ActiveX controls realize the proposed system. In the developed system, visualization and dimensional inspection of the measured point data are done directly on the Web: conversion of the point data into a CAD file or a VRML form is unnecessary. Dimensional verification results and design modification ideas are uploaded to markups and/or XML files during collaboration processes. Collaborators review the markup results created by others to produce a good design result on the Web. The use of XML files allows information sharing on the Web to be independent of the platform of the developed system. It is possible to diversify the information sharing capability among design collaborators. Validity and effectiveness of the developed system has been confirmed by case studies

  19. Formal verification of algorithms for critical systems

    Science.gov (United States)

    Rushby, John M.; Von Henke, Friedrich

    1993-01-01

    We describe our experience with formal, machine-checked verification of algorithms for critical applications, concentrating on a Byzantine fault-tolerant algorithm for synchronizing the clocks in the replicated computers of a digital flight control system. First, we explain the problems encountered in unsynchronized systems and the necessity, and criticality, of fault-tolerant synchronization. We give an overview of one such algorithm, and of the arguments for its correctness. Next, we describe a verification of the algorithm that we performed using our EHDM system for formal specification and verification. We indicate the errors we found in the published analysis of the algorithm, and other benefits that we derived from the verification. Based on our experience, we derive some key requirements for a formal specification and verification system adequate to the task of verifying algorithms of the type considered. Finally, we summarize our conclusions regarding the benefits of formal verification in this domain, and the capabilities required of verification systems in order to realize those benefits.

  20. Myeloid Conditioning with c-kit-Targeted CAR-T Cells Enables Donor Stem Cell Engraftment.

    Science.gov (United States)

    Arai, Yasuyuki; Choi, Uimook; Corsino, Cristina I; Koontz, Sherry M; Tajima, Masaki; Sweeney, Colin L; Black, Mary A; Feldman, Steven A; Dinauer, Mary C; Malech, Harry L

    2018-05-02

    We report a novel approach to bone marrow (BM) conditioning using c-kit-targeted chimeric antigen receptor T (c-kit CAR-T) cells in mice. Previous reports using anti-c-kit or anti-CD45 antibody linked to a toxin such as saporin have been promising. We developed a distinctly different approach using c-kit CAR-T cells. Initial studies demonstrated in vitro killing of hematopoietic stem cells by c-kit CAR-T cells but poor expansion in vivo and poor migration of CAR-T cells into BM. Pre-treatment of recipient mice with low-dose cyclophosphamide (125 mg/kg) together with CXCR4 transduction in the CAR-T cells enhanced trafficking to and expansion in BM (c-kit + population (9.0%-0.1%). Because congenic Thy1.1 CAR-T cells were used in the Thy1.2-recipient mice, anti-Thy1.1 antibody could be used to deplete CAR-T cells in vivo before donor BM transplant. This achieved 20%-40% multilineage engraftment. We applied this conditioning to achieve an average of 28% correction of chronic granulomatous disease mice by wild-type BM transplant. Our findings provide a proof of concept that c-kit CAR-T cells can achieve effective BM conditioning without chemo-/radiotherapy. Our work also demonstrates that co-expression of a trafficking receptor can enhance targeting of CAR-T cells to a designated tissue. Published by Elsevier Inc.

  1. Challenges for effective WMD verification

    International Nuclear Information System (INIS)

    Andemicael, B.

    2006-01-01

    Effective verification is crucial to the fulfillment of the objectives of any disarmament treaty, not least as regards the proliferation of weapons of mass destruction (WMD). The effectiveness of the verification package depends on a number of factors, some inherent in the agreed structure and others related to the type of responses demanded by emerging challenges. The verification systems of three global agencies-the IAEA, the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO, currently the Preparatory Commission), and the Organization for the Prohibition of Chemical Weapons (OPCW)-share similarities in their broad objectives of confidence-building and deterrence by assuring members that rigorous verification would deter or otherwise detect non-compliance. Yet they are up against various constraints and other issues, both internal and external to the treaty regime. These constraints pose major challenges to the effectiveness and reliability of the verification operations. In the nuclear field, the IAEA safeguards process was the first to evolve incrementally from modest Statute beginnings to a robust verification system under the global Treaty on the Non-Proliferation of Nuclear Weapons (NPT). The nuclear non-proliferation regime is now being supplemented by a technology-intensive verification system of the nuclear test-ban treaty (CTBT), a product of over three decades of negotiation. However, there still remain fundamental gaps and loopholes in the regime as a whole, which tend to diminish the combined effectiveness of the IAEA and the CTBT verification capabilities. He three major problems are (a) the lack of universality of membership, essentially because of the absence of three nuclear weapon-capable States-India, Pakistan and Israel-from both the NPT and the CTBT, (b) the changes in US disarmament policy, especially in the nuclear field, and (c) the failure of the Conference on Disarmament to conclude a fissile material cut-off treaty. The world is

  2. LANL12-RS-108J Report on Device Modeler Testing of the Device Modeler Tool Kit. DMTK in FY14

    Energy Technology Data Exchange (ETDEWEB)

    Temple, Brian Allen [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States); Pimentel, David A. [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)

    2014-09-28

    This document covers the various testing and modifications of the Device Modeler Tool Kit (DMTK) for project LANL12-RS-108J in FY14. The testing has been comprised of different device modelers and trainees for device modeling using DMTK on the secure network for a few test problems. Most of these problems have been synthetic data problems. There has been a local secure network training drill where one of the trainees has used DMTK for real data. DMTK has also been used on a laptop for a deployed real data training drill. Once DMTK gets into the home team, it will be used for more training drills (TDs) which will contain real data in the future.

  3. Study and preparation of 99Tcm-GP kit for lung ventilation imaging

    International Nuclear Information System (INIS)

    Zhu Lin; Meng Fanmin; Zhang Jihong; Hong Tao; Liu Yunzhong; Liu Xiujie

    1997-01-01

    The preparation of the lyophilizing reagent, D-glucose-l-phosphate (GP) kit and the method of using this kit to label 99 Tc m to form 99 Tc m -GP for lung ventilation imaging at room temperature in a simple, rapid procedure are described. The stability of the lyophilizing reagent kit under various stock conditions is examined. The results show that all of the 99 Tc m -GP yields by the lyophilizing reagent kit are above 95% at 4 degree C (cold), 20-25 degree C (room temperature) and 40 degree C (oven) for 180, 90 and 3 days, respectively. The clinical practice indicates that in comparison with 99 Tc m -DTPA, 99 Tc m -GP has remarkable difference (P 99 Tc m -GP is an ideal radioaerosol for SPECT studies of lung ventilation. It has high alveolar deposition rate but low adhesion in the major airways compared to those of 99 Tc m -DTPA. 99 Tc m -GP also features prolonged pulmonary clearance time

  4. A Syntactic-Semantic Approach to Incremental Verification

    OpenAIRE

    Bianculli, Domenico; Filieri, Antonio; Ghezzi, Carlo; Mandrioli, Dino

    2013-01-01

    Software verification of evolving systems is challenging mainstream methodologies and tools. Formal verification techniques often conflict with the time constraints imposed by change management practices for evolving systems. Since changes in these systems are often local to restricted parts, an incremental verification approach could be beneficial. This paper introduces SiDECAR, a general framework for the definition of verification procedures, which are made incremental by the framework...

  5. Development of an instant 99mTc labelled HIG kit for localization of infection/inflammation

    International Nuclear Information System (INIS)

    Chen Fang; Zhang Yumin; Zhou Qian

    1995-01-01

    99m Tc labelled polyclonal human immunoglobulin G(HIG) is a novel agent for detecting infection and inflammation. We report the preparation, quality control, pharmacology and preliminary clinical evaluation of this imaging agent. After modification of HIG and purification, the HIG kit was formulated and lyofilized. Labelling yield and radiochemical purity were determined by TLC-SG, PC and Sephadex G-50 column chromatography. Animal models for pharmacologic experiments were mice, rats and rabbits. The labelling yield was 99% immediately after mixing HIG with 99m Tc and more than 90% of radioactivity was retained after keeping the labelled product at room temperature 24 hours post labelling. There were good accumulation and high T/B ratio in animal models (rats and rabbits bearing turpentine and Staphylococcus aureus induced inflammatory or infections foci). The results showed that this new agent is nearly ideal for localization of infections/inflammatory lesions

  6. Verification and validation benchmarks.

    Energy Technology Data Exchange (ETDEWEB)

    Oberkampf, William Louis; Trucano, Timothy Guy

    2007-02-01

    Verification and validation (V&V) are the primary means to assess the accuracy and reliability of computational simulations. V&V methods and procedures have fundamentally improved the credibility of simulations in several high-consequence fields, such as nuclear reactor safety, underground nuclear waste storage, and nuclear weapon safety. Although the terminology is not uniform across engineering disciplines, code verification deals with assessing the reliability of the software coding, and solution verification deals with assessing the numerical accuracy of the solution to a computational model. Validation addresses the physics modeling accuracy of a computational simulation by comparing the computational results with experimental data. Code verification benchmarks and validation benchmarks have been constructed for a number of years in every field of computational simulation. However, no comprehensive guidelines have been proposed for the construction and use of V&V benchmarks. For example, the field of nuclear reactor safety has not focused on code verification benchmarks, but it has placed great emphasis on developing validation benchmarks. Many of these validation benchmarks are closely related to the operations of actual reactors at near-safety-critical conditions, as opposed to being more fundamental-physics benchmarks. This paper presents recommendations for the effective design and use of code verification benchmarks based on manufactured solutions, classical analytical solutions, and highly accurate numerical solutions. In addition, this paper presents recommendations for the design and use of validation benchmarks, highlighting the careful design of building-block experiments, the estimation of experimental measurement uncertainty for both inputs and outputs to the code, validation metrics, and the role of model calibration in validation. It is argued that the understanding of predictive capability of a computational model is built on the level of

  7. Verification of Ceramic Structures

    Science.gov (United States)

    Behar-Lafenetre, Stephanie; Cornillon, Laurence; Rancurel, Michael; De Graaf, Dennis; Hartmann, Peter; Coe, Graham; Laine, Benoit

    2012-07-01

    In the framework of the “Mechanical Design and Verification Methodologies for Ceramic Structures” contract [1] awarded by ESA, Thales Alenia Space has investigated literature and practices in affiliated industries to propose a methodological guideline for verification of ceramic spacecraft and instrument structures. It has been written in order to be applicable to most types of ceramic or glass-ceramic materials - typically Cesic®, HBCesic®, Silicon Nitride, Silicon Carbide and ZERODUR®. The proposed guideline describes the activities to be performed at material level in order to cover all the specific aspects of ceramics (Weibull distribution, brittle behaviour, sub-critical crack growth). Elementary tests and their post-processing methods are described, and recommendations for optimization of the test plan are given in order to have a consistent database. The application of this method is shown on an example in a dedicated article [7]. Then the verification activities to be performed at system level are described. This includes classical verification activities based on relevant standard (ECSS Verification [4]), plus specific analytical, testing and inspection features. The analysis methodology takes into account the specific behaviour of ceramic materials, especially the statistical distribution of failures (Weibull) and the method to transfer it from elementary data to a full-scale structure. The demonstration of the efficiency of this method is described in a dedicated article [8]. The verification is completed by classical full-scale testing activities. Indications about proof testing, case of use and implementation are given and specific inspection and protection measures are described. These additional activities are necessary to ensure the required reliability. The aim of the guideline is to describe how to reach the same reliability level as for structures made of more classical materials (metals, composites).

  8. As Built Verification Plan for Cask Transportation Facility Modifications (CTFM) - Project A.5 and A.6

    International Nuclear Information System (INIS)

    LANE, K.I.

    2000-01-01

    This document establishes an As-built Verification Plan (AVP) for implementing requirements in PHMC Engineering Requirements HNF-PRO-1819, Rev. 4, Sections 2.8.3.d and 2.10.8 and Spent Nuclear Fuels (SNF) Project Administrative Procedure EN-6-012-01. This AVP defines and implements approved processes to document the physical configuration of the project scope installed within the facility and identify discrepancies between the associated project engineering drawings and the field configuration, and the component index (CI) database as defined in AP EN 6-005-02. This AVP defines requirements for project activities verifying conformance of structures, systems, and components (SSCs) to project specified requirements

  9. Teen PACK: Population Awareness Campaign Kit.

    Science.gov (United States)

    Zero Population Growth, Inc., Washington, DC.

    This packet of instructional materials is designed to teach teenagers about the effects of overpopulation on the world and on the individual. Information is presented in three related booklets. The first of the three parts of the "Teen Population Awareness Campaign Kit," illustrates overpopulation through profiles of teens living in…

  10. Is flow verification necessary

    International Nuclear Information System (INIS)

    Beetle, T.M.

    1986-01-01

    Safeguards test statistics are used in an attempt to detect diversion of special nuclear material. Under assumptions concerning possible manipulation (falsification) of safeguards accounting data, the effects on the statistics due to diversion and data manipulation are described algebraically. A comprehensive set of statistics that is capable of detecting any diversion of material is defined in terms of the algebraic properties of the effects. When the assumptions exclude collusion between persons in two material balance areas, then three sets of accounting statistics are shown to be comprehensive. Two of the sets contain widely known accountancy statistics. One of them does not require physical flow verification - comparisons of operator and inspector data for receipts and shipments. The third set contains a single statistic which does not require physical flow verification. In addition to not requiring technically difficult and expensive flow verification, this single statistic has several advantages over other comprehensive sets of statistics. This algebraic approach as an alternative to flow verification for safeguards accountancy is discussed in this paper

  11. Recommendations for adaptation and validation of commercial kits for biomarker quantification in drug development.

    Science.gov (United States)

    Khan, Masood U; Bowsher, Ronald R; Cameron, Mark; Devanarayan, Viswanath; Keller, Steve; King, Lindsay; Lee, Jean; Morimoto, Alyssa; Rhyne, Paul; Stephen, Laurie; Wu, Yuling; Wyant, Timothy; Lachno, D Richard

    2015-01-01

    Increasingly, commercial immunoassay kits are used to support drug discovery and development. Longitudinally consistent kit performance is crucial, but the degree to which kits and reagents are characterized by manufacturers is not standardized, nor are the approaches by users to adapt them and evaluate their performance through validation prior to use. These factors can negatively impact data quality. This paper offers a systematic approach to assessment, method adaptation and validation of commercial immunoassay kits for quantification of biomarkers in drug development, expanding upon previous publications and guidance. These recommendations aim to standardize and harmonize user practices, contributing to reliable biomarker data from commercial immunoassays, thus, enabling properly informed decisions during drug development.

  12. 75 FR 13292 - Determination That HalfLytely and Bisacodyl Tablets Bowel Prep Kit (Containing 4 Bisacodyl...

    Science.gov (United States)

    2010-03-19

    ... determined that HALFLYTELY AND BISACODYL TABLETS BOWEL PREP KIT (polyethylene glycol (PEG) 3350, sodium... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution... whether HALFLYTELY AND BISACODYL TABLETS BOWEL PREP KIT (PEG-3350, sodium chloride, sodium bicarbonate...

  13. Procedure generation and verification

    International Nuclear Information System (INIS)

    Sheely, W.F.

    1986-01-01

    The Department of Energy has used Artificial Intelligence of ''AI'' concepts to develop two powerful new computer-based techniques to enhance safety in nuclear applications. The Procedure Generation System, and the Procedure Verification System, can be adapted to other commercial applications, such as a manufacturing plant. The Procedure Generation System can create a procedure to deal with the off-normal condition. The operator can then take correct actions on the system in minimal time. The Verification System evaluates the logic of the Procedure Generator's conclusions. This evaluation uses logic techniques totally independent of the Procedure Generator. The rapid, accurate generation and verification of corrective procedures can greatly reduce the human error, possible in a complex (stressful/high stress) situation

  14. Windows 7 resource kit

    CERN Document Server

    Northrup, Tony; Honeycutt, Jerry; Wilson, Ed

    2009-01-01

    In-depth and comprehensive, this RESOURCE KIT delivers the information you need to administer your Windows 7 system. You get authoritative technical guidance from those who know the technology best-Microsoft Most Valuable Professionals (MVPs) and the Windows 7 product team-along with essential scripts and resources. In addition, "Direct from the Source" sidebars offer deep insights and troubleshooting tips from the Windows 7 team. Get expert guidance on how to: Use Microsoft Deployment Toolkit best practices and tools. Plan user-state migration and test application compatibility.

  15. Results with commercial radioassay kits compared with microbiological assay of folate in serum and whole-blood

    International Nuclear Information System (INIS)

    McGown, E.L.; Lewis, C.M.; Dong, M.H.; Sauberlich, H.E.

    1978-01-01

    Results with three commercial folate radioassay kits [Bio-Rad, New England Nuclear (NEN), and RIA Products] were compared with those by microbiological assay for more than 200 samples of human serum and whole blood. All but one kit (NEN) compared favorably with the microbiological assay for serum samples, although there were notable diagnostic discrepancies. Two kits (NEN and Bio-Rad) were tested on whole-blood samples; both yielded values significantly higher than those by microbiological assay. The frequency distributions of erythrocyte folate data differed strikingly between the two kits; the NEN method yielded a much narrower range of normal values than did either the Bio-Rad or the microbiological assay. Radioassay kits appear to be suitable diagnostic agents for serum folate, if the behavior of a particular kit is investigated thoroughly before its routine use. However, the diagnostic value of radioassays of erythrocyte folate needs to be validated

  16. Preparation of a CNP radioimmunoassay kit and its primary clinical application

    International Nuclear Information System (INIS)

    Chen Sujuan; Dong Xiaojun; Gao Zhiying; Zhong Hui; Li Zhenjia; Liu Runmei

    2003-01-01

    Objective: To develop a RIA kit for measurement of C-type natriuretic peptide (CNP) and to investigate its in clinical use. Methods: Conjugated CNP-TG was used to immunize the rabbit and the antibody against CNP was prepared. CNP RIA kits were made from it. Plasma CNP concentrations of 83 controls, 54 patients with coronary heart disease, 25 patients with heart failure and 73 patients with primary hypertension were determined with this RIA kit. Results: The sensitivity of detection was 5 pg/ml. The specificity of CNP anti-serum was high and did not react with ANP, NT, NPY, ET, CGRP and CT. The intra and interassy CVs were <10% and <15% respectively. The plasma levels of patients with coronary heart disease, heart failure and primary hypertension were 62.5 pg/ml, 47.9 pg/ml, 56.4 pg/ml respectively. There were all significantly higher than the level in controls (27.5 pg/ml). Conclusion: RIA of CNP with this kit is a simple, rapid method. It is a reliable means for studying the role of CNP in various physiological and pathophysiological states

  17. Clean room for the production of cold kits: two year experience with the production of kits for 99mTc radiopharmaceuticals

    International Nuclear Information System (INIS)

    Muralidharan, Sheela H.; Nair, Preeti; Ghodke, Archana S.; Pillai, Thara; Sheri, Kumar Uma; Vanaja, R.; Mehra, Kiran S.; Sachdev, S.S.; Sivaprasad, N.

    2010-01-01

    A new clean room has been designed and constructed at Radiopharmaceuticals Programme, BRIT keeping in view the functional aspects for the production of 'cold' kits for the preparation of 99m Tc radiopharmaceuticals for supply to nuclear medicine centers and is in operation, since October, 2008. This clean room is the first clean room in the country designed exclusively for cold kit production. The clean room was validated and trial batches were produced and quality controlled prior to put it in regular production operation. The clean environment is maintained by separate AHU (air handling unit) located out side the clean room. A technical crew maintain the AHU unit and maintain record of parameters such as humidity, air flow, blower speed, chiller temperature etc. During a typical batch production not more than two persons are present in the formulation room. The formulated solution (filtered through 0.22μ membrane filter) is passed though a pass box between the formulation and dispensing area. The no. of people allowed in the dispensing area which is a critical area of class 100 is restricted to not more than four that too no person is allowed to be in between direct flow of HEPA filtered air and the dispensing table. The number of vials to be dispensed is arranged in trays and 1 ml of the formulated sterile solution is dispensed into each vial and the vials are transferred in to the lyophilization chamber. Sterile vials are introduced into class 100 area and the vials are removed after lyophilization though a pass box. After lyophilization vials are sealed with aluminum caps and stored at 2-10 deg C. Since the commissioning of the new clean room, about 120 batches of 10 different kit products were prepared and 1,20,000 kit vials were supplied to various hospitals for nuclear medicine investigation

  18. A Scalable Approach for Hardware Semiformal Verification

    OpenAIRE

    Grimm, Tomas; Lettnin, Djones; Hübner, Michael

    2018-01-01

    The current verification flow of complex systems uses different engines synergistically: virtual prototyping, formal verification, simulation, emulation and FPGA prototyping. However, none is able to verify a complete architecture. Furthermore, hybrid approaches aiming at complete verification use techniques that lower the overall complexity by increasing the abstraction level. This work focuses on the verification of complex systems at the RT level to handle the hardware peculiarities. Our r...

  19. Evaluation of a clinic-based cholinesterase test kit for the Washington State Cholinesterase Monitoring Program.

    Science.gov (United States)

    Hofmann, Jonathan N; Carden, Angela; Fenske, Richard A; Ruark, Harold E; Keifer, Matthew C

    2008-07-01

    The Washington State Cholinesterase Monitoring Program for pesticide handlers requires blood draws at local clinics, with samples tested at a central laboratory. At present, workers with inhibited cholinesterase activity may be re-exposed before they can be removed from work. In this study we explored the option of on-site testing at local clinics using the EQM Test-mate Kittrade mark, a portable cholinesterase test kit. Test kit cholinesterase activity measurements were performed on 50 blood samples by our research staff, and compared to measurements on the same samples by the Washington State Public Health Laboratory. Another set of samples was also analyzed with the test kit by medical staff at an eastern Washington clinic. Triplicate measurements with the test kit had a 3.3% average coefficient of variation (CV) for plasma cholinesterase (PChE), and a 3.5% average CV for erythrocyte cholinesterase (AChE) measurements. The kit's PChE measurements were similar to PHL measurements (average ratio of 0.98) when performed in the laboratory, but had a tendency to underestimate activity when used in the clinic setting (average ratio of 0.87). The kit systematically overestimated AChE activity by 42-48% relative to the PHL measurements, regardless of where the samples were analyzed. This easy-to-use test kit appeared to be a viable method for clinic-based PChE measurements, but was less consistent for AChE measurements performed in the clinic. Absolute measurements with the kit need to be evaluated carefully relative to standardized methods. (c) 2008 Wiley-Liss, Inc.

  20. DogMATIC--A Remote Biospecimen Collection Kit for Biobanking.

    Science.gov (United States)

    Milley, Kristi M; Nimmo, Judith S; Bacci, Barbara; Ryan, Stewart D; Richardson, Samantha J; Danks, Janine A

    2015-08-01

    Canine tumors are valuable comparative oncology models. This research was designed to create a sustainable biobank of canine mammary tumors for breast cancer research. The aim was to provide a well-characterized sample cohort for specimen sharing, data mining, and long-term research aims. Canine mammary tumors are most frequently managed at a local veterinary clinic or hospital. We adopted a biobank framework based on a large number of participating veterinary hospitals and clinics acting as collection centers that were serviced by a centralized storage facility. Recruitment was targeted at rural veterinary clinics. A tailored, stable collection kit (DogMATIC) was designed that was used by veterinarians in remote or rural locations to collect both fresh and fixed tissue for submission to the biobank. To validate this methodology the kit design, collection rate, and sample quality were analyzed. The Australian Veterinary Cancer Biobank was established as a network of 47 veterinary clinics and three veterinary pathology laboratories spanning over 200,000 km(2). In the first 12 months, 30 canine mammary tumor cases were submitted via the DogMATIC kit. Pure intact RNA was isolated in over 80% of samples with an average yield of 14.49 μg. A large network biobank, utilizing off-site collection with the DogMATIC kit, was successfully coordinated. The creation of the Australian Veterinary Cancer Biobank has established a long-term, sustainable, comparative oncology research resource in Australia. There are broader implications for biobanking with this very different form of collection and banking.

  1. MOV reliability evaluation and periodic verification scheduling

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.

    1996-12-01

    The purpose of this paper is to establish a periodic verification testing schedule based on the expected long term reliability of gate or globe motor operated valves (MOVs). The methodology in this position paper determines the nominal (best estimate) design margin for any MOV based on the best available information pertaining to the MOVs design requirements, design parameters, existing hardware design, and present setup. The uncertainty in this margin is then determined using statistical means. By comparing the nominal margin to the uncertainty, the reliability of the MOV is estimated. The methodology is appropriate for evaluating the reliability of MOVs in the GL 89-10 program. It may be used following periodic testing to evaluate and trend MOV performance and reliability. It may also be used to evaluate the impact of proposed modifications and maintenance activities such as packing adjustments. In addition, it may be used to assess the impact of new information of a generic nature which impacts safety related MOVs.

  2. MOV reliability evaluation and periodic verification scheduling

    International Nuclear Information System (INIS)

    Bunte, B.D.

    1996-01-01

    The purpose of this paper is to establish a periodic verification testing schedule based on the expected long term reliability of gate or globe motor operated valves (MOVs). The methodology in this position paper determines the nominal (best estimate) design margin for any MOV based on the best available information pertaining to the MOVs design requirements, design parameters, existing hardware design, and present setup. The uncertainty in this margin is then determined using statistical means. By comparing the nominal margin to the uncertainty, the reliability of the MOV is estimated. The methodology is appropriate for evaluating the reliability of MOVs in the GL 89-10 program. It may be used following periodic testing to evaluate and trend MOV performance and reliability. It may also be used to evaluate the impact of proposed modifications and maintenance activities such as packing adjustments. In addition, it may be used to assess the impact of new information of a generic nature which impacts safety related MOVs

  3. Commercial Milk Enzyme-Linked Immunosorbent Assay (ELISA) Kit Reactivities to Purified Milk Proteins and Milk-Derived Ingredients.

    Science.gov (United States)

    Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L

    2016-07-01

    Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®

  4. KIT mutation analysis in mast cell neoplasms

    DEFF Research Database (Denmark)

    Arock, M; Sotlar, K; Akin, C

    2015-01-01

    mutations in patients with mastocytosis at diagnosis and during follow-up with sufficient precision and sensitivity in daily practice. In addition, we provide recommendations for sampling and storage of diagnostic material as well as a robust diagnostic algorithm. Using highly sensitive assays, KIT D816V...... can be detected in peripheral blood leukocytes from most patients with systemic mastocytosis (SM) that is a major step forward in screening and SM diagnosis. In addition, the KIT D816V allele burden can be followed quantitatively during the natural course or during therapy. Our recommendations should...... greatly facilitate diagnostic and follow-up investigations in SM in daily practice as well as in clinical trials. In addition, the new tools and algorithms proposed should lead to a more effective screen, early diagnosis of SM and help to avoid unnecessary referrals....

  5. A discussion on the proposal of construction of a verification facility at CIAE for the AD-RCNPS R and D

    International Nuclear Information System (INIS)

    Ding Dazhao

    2000-01-01

    ADS is a prospective innovative nuclear power system based on the development of high power proton accelerator and well developed technology of power reactor. Its advantage and benefit in respect of waste transmutation and fuel breeding were recognized by international nuclear community. ADS provides more flexibility from viewpoint of operation and control. To made ADS to be a reliable one, a series of important problem in the components of ADS--accelerator, reactor, material and neutron physics are enumerated. The R and D of a new nuclear power system is a long term activity, including conceptual study, verification of the principle, experimental facility, prototype and commercial demonstration. To construction a verification facility is an essential step in promoting the R and D of ADS from conceptual study to technical comprehension. A verification facility that consisted of a swimming pool reactor at CIAE driven by a pulsed low energy high current accelerator is proposed. According to those experiments that should be carried out at this facility, the specifications of accelerator and the modification of the reactor core structure are given

  6. Review papers The role of KIT gene mutations in pathogenesis of pediatric mastocytosis

    Directory of Open Access Journals (Sweden)

    Joanna Dawicka

    2015-03-01

    Full Text Available Mastocytosis is characterized by excessive proliferation and accumulation of mast cells in skin and/or other organs. Two forms of the disease, cutaneous and systemic mastocytosis, differ significantly in symptomatology and clinical course. KIT mutations play an important role in the pathogenesis of the disease. The presence of p.D816V KIT mutation was detected in the vast majority of adults with systemic mastocytosis. The role of KIT mutations in childhood-onset mastocytosis remains a matter of discussion. More recent studies have shown that cutaneous mastocytosis, which is the most common clinical manifestation of the disease in children, has a genetic background. In contrast to adults, different types of KIT mutations have been described in pediatric and familial mastocytosis. The understanding of the molecular mechanisms in mastocytosis enables targeted therapy using tyrosine kinase inhibitors.

  7. Milk intake in kits: not only the total amount matters

    Directory of Open Access Journals (Sweden)

    Alberto Arnau Bonachera

    2017-06-01

    Full Text Available The aim of this work was to identify milk intake variation patterns in kits throughout lactation, to evaluate their permanent maternal component and their relationships with the performance of kits before and after weaning. To achieve this goal, we used 73 rabbit does, controlled between the 1st and the 4th lactation, which kindled 229 litters with a total of 2225 kits. The daily milk intake records per young rabbit were analysed using a principal component analysis (PCA. We found that 72.3% of the variability was explained by the first 3 principal components (PCs. PC1 explained 46.4% of the total variability, was associated with the total amount of milk intake during lactation and presented a repeatability of 0.27 (P0.05. This component was little related to performance traits. Therefore, it seems that milk plays 2 different roles at the beginning of feed intake; the most important would affect development of the kits and thus is related with high intake. The second one, for a given total amount of milk intake during lactation, would create a kind of competition between milk and feed intake at the end of lactation. The effects of both components still persist during the growing period and seem to be moderately affected by the mother.

  8. Extending Mechanical Construction Kits to Incorporate Passive and Compliant Elements for Educational Robotics

    DEFF Research Database (Denmark)

    Assaf, Dorit; Larsen, Jørgen Christian; Reichardt, Markus

    2012-01-01

    artificial intelligence and biomechanics to students with different backgrounds. The robots we use both for research and education are usually built incorporating compliant materials as well as passive dynamics. These kind of properties are often not available in classical robot kits or mechanical...... construction kits. In this paper we describe some of the robots we use for education. So far we built the robots using 3D printing technology which is convenient but too expensive for class use. Our aim is to find cheaper, commercially available solutions. After a short review on educational robot kits...

  9. Semiclassical anomalies of the quantum mechanical systems and their modifications for the asymptotic matching

    International Nuclear Information System (INIS)

    Deniz, Coskun

    2011-01-01

    JWKB solutions to the Initial Value Problems (IVPs) of the Time Independent Schrodinger's Equation (TISE) for the Simple Linear Potentials (SLPs) with a turning point parameter have been studied according to the turning points by graphical analysis to test the results of the JWKB solutions and suggested modifications. The anomalies happening in the classically inaccessible region where the SLP function is smaller than zero and the results of the suggested modifications, which are in consistent with the quantum mechanical theories, to remove these anomalies in this region have been presented. The origins of the anomalies and verifications of the suggested modifications showing a great success in the results have also been studied in terms of a suggested M ij =S ∼ i-1,j matrix elements made up of the JWKB expansion terms, S i-1,j (where i = 1, 2, 3 and j 1, 2). The results of the modifications for the IVPs and their application to the Bound State Problems (BSPs) with an example application of the Harmonic Oscillator (HO) have been presented and their generalization for any potential function have been discussed and classified accordingly.

  10. Hotspot mutations in KIT receptor differentially modulate its allosterically coupled conformational dynamics: impact on activation and drug sensitivity.

    Directory of Open Access Journals (Sweden)

    Isaure Chauvot de Beauchêne

    2014-07-01

    Full Text Available Receptor tyrosine kinase KIT controls many signal transduction pathways and represents a typical allosterically regulated protein. The mutation-induced deregulation of KIT activity impairs cellular physiological functions and causes serious human diseases. The impact of hotspots mutations (D816H/Y/N/V and V560G/D localized in crucial regulatory segments, the juxtamembrane region (JMR and the activation (A- loop, on KIT internal dynamics was systematically studied by molecular dynamics simulations. The mutational outcomes predicted in silico were correlated with in vitro and in vivo activation rates and drug sensitivities of KIT mutants. The allosteric regulation of KIT in the native and mutated forms is described in terms of communication between the two remote segments, JMR and A-loop. A strong correlation between the communication profile and the structural and dynamical features of KIT in the native and mutated forms was established. Our results provide new insight on the determinants of receptor KIT constitutive activation by mutations and resistance of KIT mutants to inhibitors. Depiction of an intra-molecular component of the communication network constitutes a first step towards an integrated description of vast communication pathways established by KIT in physiopathological contexts.

  11. Survey on Offline Finger Print Verification System

    NARCIS (Netherlands)

    Suman, R.; Kaur, R.

    2012-01-01

    The fingerprint verification, means where "verification" implies a user matching a fingerprint against a single fingerprint associated with the identity that the user claims. Biometrics can be classified into two types Behavioral (signature verification, keystroke dynamics, etc.) And Physiological

  12. In-core Instrument Subcritical Verification (INCISV) - Core Design Verification Method - 358

    International Nuclear Information System (INIS)

    Prible, M.C.; Heibel, M.D.; Conner, S.L.; Sebastiani, P.J.; Kistler, D.P.

    2010-01-01

    According to the standard on reload startup physics testing, ANSI/ANS 19.6.1, a plant must verify that the constructed core behaves sufficiently close to the designed core to confirm that the various safety analyses bound the actual behavior of the plant. A large portion of this verification must occur before the reactor operates at power. The INCISV Core Design Verification Method uses the unique characteristics of a Westinghouse Electric Company fixed in-core self powered detector design to perform core design verification after a core reload before power operation. A Vanadium self powered detector that spans the length of the active fuel region is capable of confirming the required core characteristics prior to power ascension; reactivity balance, shutdown margin, temperature coefficient and power distribution. Using a detector element that spans the length of the active fuel region inside the core provides a signal of total integrated flux. Measuring the integrated flux distributions and changes at various rodded conditions and plant temperatures, and comparing them to predicted flux levels, validates all core necessary core design characteristics. INCISV eliminates the dependence on various corrections and assumptions between the ex-core detectors and the core for traditional physics testing programs. This program also eliminates the need for special rod maneuvers which are infrequently performed by plant operators during typical core design verification testing and allows for safer startup activities. (authors)

  13. KIT-negative Gastrointestinal Stromal Tumor in a Child: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Se Woong; Lee, Young Hwan; Park, Sang Hyeon; Choi, Du young; Choi, Geum Ha [Wonkwang University School of Medicine and Hospital, Iksan (Korea, Republic of)

    2011-01-15

    We report here on the imaging findings of the case of KIT-negative gastrointestinal stromal tumor (GIST) in the stomach of a 12-year-old girl. Radiologic studies revealed the presence of a huge exophytic growing mass that originated from the gastric wall and this mass consisted of solid and cystic components on USG, CT and MR. The cystic regions were mainly located at the periphery of the mass and they were revealed to be myxoid degeneration and hemorrhage on histopathologic examination. The tumor consisted of epithelioid and typical spindle cells and they showed negative immunoreactivity for KIT. Although KIT-negative GISTs are rare, they can be considered in the differential diagnosis when a large heterogeneous extraluminal mass that contains solid portions and various degrees of peripheral cystic regions is observed

  14. Fundamental studies on the development of C-peptide radioimmunoassay kit

    International Nuclear Information System (INIS)

    Nakazawa, Nobuhiko; Maki, Kentaro; Ogawa, Hiroshi; Ikeda, Osamu

    1976-01-01

    We have studied the development of the C-peptide radioimmunoassay kit which is usable in the pancreatic function test with satisfactory results. The C-peptide antiserum was prepared by immunizing rabbits with synthetic human connecting peptide. The antiserum revealed no cross reaction with any C-peptides other than human C-peptide, porcine insulin and gastrointestinal hormone, and showed high specificity to human C-peptide. We adopted the double antibody method in B,F separation, and chose 4 0 C, 48 hrs. for 1st. incubation and 4 0 C, 24 hrs. for 2nd. incubation. On this kit, the assay range was 0.5 ng/ml-30 ng/ml, the recovery rate was 98.4%-107.8% in the recovery test, the coefficient of variance was 6.2% in the intra assay and was 7.6% in the inter assay. We think this kit is sufficiently usable to assay C-peptide in blood. (auth.)

  15. Fundamental studies on the development of C-peptide radioimmunoassay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, N; Maki, K; Ogawa, H; Ikeda, O [Daiichi Radioisotope Labs. Ltd., Tokyo (Japan)

    1976-05-01

    We have studied the development of the C-peptide radioimmunoassay kit which is usable in the pancreatic function test with satisfactory results. The C-peptide antiserum was prepared by immunizing rabbits with synthetic human connecting peptide. The antiserum revealed no cross reaction with any C-peptides other than human C-peptide, porcine insulin and gastrointestinal hormone, and showed high specificity to human C-peptide. We adopted the double antibody method in B,F separation, and chose 4/sup 0/C, 48 hrs. for 1st. incubation and 4/sup 0/C, 24 hrs. for 2nd. incubation. On this kit, the assay range was 0.5 ng/ml-30 ng/ml, the recovery rate was 98.4%-107.8% in the recovery test, the coefficient of variance was 6.2% in the intra assay and was 7.6% in the inter assay. We think this kit is sufficiently usable to assay C-peptide in blood.

  16. Fundamental and clinical study for PHT (parathyroid hormone) kit 'Yamasa'

    International Nuclear Information System (INIS)

    Fukunaga, Masao; Otsuka, Nobuaki; Furukawa, Takako; Morita, Rikushi

    1987-01-01

    A commercially available radioimmunoassay kit (Yamasa) for parathyroid hormone (PTH) is the midregion-specific assay system. Fundamental study of the PTH kit gave favorable results for specificity, reproducibility, dilution, and recovery. The serum PTH concentration was detectable among all 41 normal volunteers. The upper and lower limits of normal for PTH in serum were found to be 600 pg/ml and 184 pg/ml, respectively. PTH values were high for chronic renal failure (6/7) and primary hyperparathyroidism (41/41), and low for malignancy associated with hypercalcemia (5/25). It seems possible to discriminate hypercalcemic from normal subjects. The serum PTH concentration from the present assay system was significantly correlated with that from conventional carboxyl-terminal PTH, midregion PTH, amino-terminal PTH, and (1 - 84) PTH assay systems. The results indicate the potential of the Yamasa kit in evaluating calcium metabolism, as well as in detecting the presence of secondary hyperparathyroidism. (Namekawa, K.)

  17. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  18. Evaluation of c-kit expression in classic Kaposi's sarcoma in a cohort of Egyptian patients

    International Nuclear Information System (INIS)

    Hussein, T.M.; El-Sabaa, B.M.; Hanafy, N.F.

    2012-01-01

    Kaposis sarcoma (KS) is in angio proliferative disorder associated with human herpes virus 8 infection. Classic Ks is the most prevalent type of KS in countries of the Mediterranean basin including Egypt. Several in vitro studies have detected C-kit expression in AIDS related-KS however, only a few studies addressed this Issue In the classic type with no data on the ethnicity of studied cases. The prospect of installing targeted anti-c-kit treatment to KS patients presents a promising avenue in KS therapeutics. Aim: To elucidate the expression of c-kit in classic KS cases and study possible relations with expression of HHV8 latency-associated nuclear antigen-1 (LANA-1) and other clinico pathological parameters. Methods: Twenty four cases of classic KS of the plaque and nodular stages in the lower limb were studied. Immunohistochemical detection of HHV8-LANA-1 and c-kit was carried out on archival paraffin embedded tissue, possession of the pathology and dermatology Departments, Alexandria School Of Medicine, Egypt. Statistical analysis of possible reltions between both antigen and clinico pathological parameters (patient age and gender and histological stage) was performed. Results: HHV8 expression was detected in 100% of cases while c-kit immunoreactivity was found in 54.2% of cases. There was no correlation between c-kit and HHV8 immunoreactivity or any of the studied clinico pathological parameters. Conclusions: This is the first report of c-kit expression in classic KS in an ethnically homogeneous cohort of arabs of the Mediterranean region. We detected c-kit expression in about half the cases with no relationship to HHV8 LANA expression or clinico pathological parameters

  19. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  20. Raman laser spectrometer optical head: qualification model assembly and integration verification

    Science.gov (United States)

    Ramos, G.; Sanz-Palomino, M.; Moral, A. G.; Canora, C. P.; Belenguer, T.; Canchal, R.; Prieto, J. A. R.; Santiago, A.; Gordillo, C.; Escribano, D.; Lopez-Reyes, G.; Rull, F.

    2017-08-01

    Raman Laser Spectrometer (RLS) is the Pasteur Payload instrument of the ExoMars mission, within the ESA's Aurora Exploration Programme, that will perform for the first time in an out planetary mission Raman spectroscopy. RLS is composed by SPU (Spectrometer Unit), iOH (Internal Optical Head), and ICEU (Instrument Control and Excitation Unit). iOH focuses the excitation laser on the samples (excitation path), and collects the Raman emission from the sample (collection path, composed on collimation system and filtering system). Its original design presented a high laser trace reaching to the detector, and although a certain level of laser trace was required for calibration purposes, the high level degrades the Signal to Noise Ratio confounding some Raman peaks. So, after the bread board campaign, some light design modifications were implemented in order to fix the desired amount of laser trace, and after the fabrication and the commitment of the commercial elements, the assembly and integration verification process was carried out. A brief description of the iOH design update for the engineering and qualification model (iOH EQM) as well as the assembly process are briefly described in this papers. In addition, the integration verification and the first functional tests, carried out with the RLS calibration target (CT), results are reported on.

  1. Fingerprint verification prediction model in hand dermatitis.

    Science.gov (United States)

    Lee, Chew K; Chang, Choong C; Johor, Asmah; Othman, Puwira; Baba, Roshidah

    2015-07-01

    Hand dermatitis associated fingerprint changes is a significant problem and affects fingerprint verification processes. This study was done to develop a clinically useful prediction model for fingerprint verification in patients with hand dermatitis. A case-control study involving 100 patients with hand dermatitis. All patients verified their thumbprints against their identity card. Registered fingerprints were randomized into a model derivation and model validation group. Predictive model was derived using multiple logistic regression. Validation was done using the goodness-of-fit test. The fingerprint verification prediction model consists of a major criterion (fingerprint dystrophy area of ≥ 25%) and two minor criteria (long horizontal lines and long vertical lines). The presence of the major criterion predicts it will almost always fail verification, while presence of both minor criteria and presence of one minor criterion predict high and low risk of fingerprint verification failure, respectively. When none of the criteria are met, the fingerprint almost always passes the verification. The area under the receiver operating characteristic curve was 0.937, and the goodness-of-fit test showed agreement between the observed and expected number (P = 0.26). The derived fingerprint verification failure prediction model is validated and highly discriminatory in predicting risk of fingerprint verification in patients with hand dermatitis. © 2014 The International Society of Dermatology.

  2. Role of ELA region in auto-activation of mutant KIT receptor: a molecular dynamics simulation insight.

    Science.gov (United States)

    Purohit, Rituraj

    2014-01-01

    KIT receptor is the prime target in gastrointestinal stromal tumor (GISTs) therapy. Second generation inhibitor, Sunitinib, binds to an inactivated conformation of KIT receptor and stabilizes it in order to prevent tumor formation. Here, we investigated the dynamic behavior of wild type and mutant D816H KIT receptor, and emphasized the extended A-loop (EAL) region (805-850) by conducting molecular dynamics simulation (∼100 ns). We analyzed different properties such as root mean square cutoff or deviation, root mean square fluctuation, radius of gyration, solvent-accessible surface area, hydrogen bonding network analysis, and essential dynamics. Apart from this, clustering and cross-correlation matrix approach was used to explore the conformational space of the wild type and mutant EAL region of KIT receptor. Molecular dynamics analysis indicated that mutation (D816H) was able to alter intramolecular hydrogen bonding pattern and affected the structural flexibility of EAL region. Moreover, flexible secondary elements, specially, coil and turns were dominated in EAL region of mutant KIT receptor during simulation. This phenomenon increased the movement of EAL region which in turn helped in shifting the equilibrium towards the active kinase conformation. Our atomic investigation of mutant KIT receptor which emphasized on EAL region provided a better insight into the understanding of Sunitinib resistance mechanism of KIT receptor and would help to discover new therapeutics for KIT-based resistant tumor cells in GIST therapy.

  3. The electronic view box: a software tool for radiation therapy treatment verification

    International Nuclear Information System (INIS)

    Bosch, Walter R.; Low, Daniel A.; Gerber, Russell L.; Michalski, Jeff M.; Graham, Mary V.; Perez, Carlos A.; Harms, William B.; Purdy, James A.

    1995-01-01

    Purpose: We have developed a software tool for interactively verifying treatment plan implementation. The Electronic View Box (EVB) tool copies the paradigm of current practice but does so electronically. A portal image (online portal image or digitized port film) is displayed side by side with a prescription image (digitized simulator film or digitally reconstructed radiograph). The user can measure distances between features in prescription and portal images and 'write' on the display, either to approve the image or to indicate required corrective actions. The EVB tool also provides several features not available in conventional verification practice using a light box. Methods and Materials: The EVB tool has been written in ANSI C using the X window system. The tool makes use of the Virtual Machine Platform and Foundation Library specifications of the NCI-sponsored Radiation Therapy Planning Tools Collaborative Working Group for portability into an arbitrary treatment planning system that conforms to these specifications. The present EVB tool is based on an earlier Verification Image Review tool, but with a substantial redesign of the user interface. A graphical user interface prototyping system was used in iteratively refining the tool layout to allow rapid modifications of the interface in response to user comments. Results: Features of the EVB tool include 1) hierarchical selection of digital portal images based on physician name, patient name, and field identifier; 2) side-by-side presentation of prescription and portal images at equal magnification and orientation, and with independent grayscale controls; 3) 'trace' facility for outlining anatomical structures; 4) 'ruler' facility for measuring distances; 5) zoomed display of corresponding regions in both images; 6) image contrast enhancement; and 7) communication of portal image evaluation results (approval, block modification, repeat image acquisition, etc.). Conclusion: The EVB tool facilitates the rapid

  4. Mutational profile of KIT and PDGFRA genes in gastrointestinal stromal tumors in Peruvian samples

    Directory of Open Access Journals (Sweden)

    José Buleje

    2015-02-01

    Full Text Available Introduction: Gastrointestinal stromal tumors (GISTs are mesenchymal neoplasms usually caused by somatic mutations in the genes KIT (c-KIT or PDGFRA. Mutation characterization has become an important exam for GIST patients because it is useful in predicting the response to the inhibitors of receptor tyrosine kinase (RTK. Objectives: The aim of this study was to determine the frequency of KIT and PDGFRA mutations in 25 GIST samples collected over two years at two national reference hospitals in Peru. There were 21 samples collected from the Instituto Nacional de Enfermedades Neoplásicas (INEN, national cancer center and 4 samples collected from Hospital A. Loayza. Methods and materials: In this retrospective study, we performed polymerase chain reaction (PCR amplification and deoxyribonucleic acid (DNA sequencing of KIT (exons 9, 11, 13, and 17 and PDGFRA (exons 12 and 18 genes in 20 FFPE (formalin-fixed, paraffin-embedded and 5 frozen GIST samples. Results: We report 21 mutations, including deletions, duplications, and missense, no mutations in 2 samples, and 2 samples with no useful DNA for further analysis. Eighty-six percent of these mutations were located in exon 11 of KIT, and 14 % were located in exon 18 of PDGFRA. Conclusions: Our study identified mutations in 21 out of 25 GIST samples from 2 referential national hospitals in Peru, and the mutation proportion follows a global tendency observed from previous studies (i.e., the majority of samples presented KIT mutations followed by a minor percentage of PDGFRA mutations. This study presents the first mutation data of the KIT and PDGFRA genes from Peruvian individuals with GIST.

  5. Countdown to Six Billion Teaching Kit.

    Science.gov (United States)

    Zero Population Growth, Inc., Washington, DC.

    This teaching kit features six activities focused on helping students understand the significance of the world population reaching six billion for our society and our environment. Featured activities include: (1) History of the World: Part Six Billion; (2) A Woman's Place; (3) Baby-O-Matic; (4) Earth: The Apple of Our Eye; (5) Needs vs. Wants; and…

  6. The eBioKit, a stand-alone educational platform for bioinformatics.

    Science.gov (United States)

    Hernández-de-Diego, Rafael; de Villiers, Etienne P; Klingström, Tomas; Gourlé, Hadrien; Conesa, Ana; Bongcam-Rudloff, Erik

    2017-09-01

    Bioinformatics skills have become essential for many research areas; however, the availability of qualified researchers is usually lower than the demand and training to increase the number of able bioinformaticians is an important task for the bioinformatics community. When conducting training or hands-on tutorials, the lack of control over the analysis tools and repositories often results in undesirable situations during training, as unavailable online tools or version conflicts may delay, complicate, or even prevent the successful completion of a training event. The eBioKit is a stand-alone educational platform that hosts numerous tools and databases for bioinformatics research and allows training to take place in a controlled environment. A key advantage of the eBioKit over other existing teaching solutions is that all the required software and databases are locally installed on the system, significantly reducing the dependence on the internet. Furthermore, the architecture of the eBioKit has demonstrated itself to be an excellent balance between portability and performance, not only making the eBioKit an exceptional educational tool but also providing small research groups with a platform to incorporate bioinformatics analysis in their research. As a result, the eBioKit has formed an integral part of training and research performed by a wide variety of universities and organizations such as the Pan African Bioinformatics Network (H3ABioNet) as part of the initiative Human Heredity and Health in Africa (H3Africa), the Southern Africa Network for Biosciences (SAnBio) initiative, the Biosciences eastern and central Africa (BecA) hub, and the International Glossina Genome Initiative.

  7. Developing teaching kit on the use of micro-hydro generator in remote area

    Directory of Open Access Journals (Sweden)

    Desak Made Megawati

    2017-04-01

    Full Text Available The study aimed at: (1 identifying the criteria of teaching kit feasibility for the advantages of micro-hydro generator in remote area; and (2 identifying the effectiveness of teaching kit implementation on the use of micro-hydro generator in remote area in order to improve the students’ concept mastery on SMP Negeri 1 Rampi South Sulawesi. The study was a research and development that adapted the 4D model, which consisted of define, design, develop, and disseminate. The teaching kit that had been developed was a syllabus, lesson plans, student’s worksheet, and assessment instrument. For the data gathering, the researcher implemented the non-test technique, in the form of product validation sheet, student’s worksheet readability questionnaire sheet, teaching implementation sheet, and test technique, in the form of concept mastery test item sheet. The results of the study show that: (1 the teaching kit on the use of micro-hydro generator in remote area that has been developed falls into the “Very Good” category for syllabus, lesson plan, and student’s worksheet; and (2 the implementation of the teaching kit on the use of micro-hydro generator in remote area has been effective to improve the students’ concept mastery in SMP Negeri 1 Rampi South Sulawesi.

  8. Automated prototyping tool-kit (APT)

    OpenAIRE

    Nada, Nader; Shing, M.; Berzins, V.; Luqi

    2002-01-01

    Automated prototyping tool-kit (APT) is an integrated set of software tools that generate source programs directly from real-time requirements. The APT system uses a fifth-generation prototyping language to model the communication structure, timing constraints, 1/0 control, and data buffering that comprise the requirements for an embedded software system. The language supports the specification of hard real-time systems with reusable components from domain specific component libraries. APT ha...

  9. Formulation of MIBI Kit as a heart imaging agent

    International Nuclear Information System (INIS)

    Widyastuti; A, Hanafiah; Yunilda; A, Laksmi; Setyowati, Sri; Y Veronika

    1999-01-01

    9 9 m Tc labelled 2-methoxy-isobutyl-isonitrile(MIBI) has been known as an imaging agent for myocardial perfusion. This radiopharmaceutical preparation gives the same satisfactory result as Thallium- 2 10TI, and presumably could replace 2 01TI because of same advantages. MIBI kit was formulated from MIBI ligand produced by RPC-BATAN which has been characterized and tested for quality. The formula used in this research referred to the formula of imported product(Cardiolite, MIBI kit produced by Dupont), and the quality control testing was performed by comparing some parameters to the imported product. The parameters used for QC testing were radiochemical purity, biodistribution in nice and heart imaging in human volunteer using gamma camera. The result of the experiment showed that the radiochemical purity was 95 % in average, biodistribution in heart to liver gave the ratio of 0.67, 1.5, and 2.53 respectively at 10, 30 and 60 minutes after injection. The result of clinical testing in some volunteers gave contrast images as good as given by Cardiolite. The optimum condition of freeze drying has been found, and the kit can be used for more than 6 months

  10. Cassini's Test Methodology for Flight Software Verification and Operations

    Science.gov (United States)

    Wang, Eric; Brown, Jay

    2007-01-01

    The Cassini spacecraft was launched on 15 October 1997 on a Titan IV-B launch vehicle. The spacecraft is comprised of various subsystems, including the Attitude and Articulation Control Subsystem (AACS). The AACS Flight Software (FSW) and its development has been an ongoing effort, from the design, development and finally operations. As planned, major modifications to certain FSW functions were designed, tested, verified and uploaded during the cruise phase of the mission. Each flight software upload involved extensive verification testing. A standardized FSW testing methodology was used to verify the integrity of the flight software. This paper summarizes the flight software testing methodology used for verifying FSW from pre-launch through the prime mission, with an emphasis on flight experience testing during the first 2.5 years of the prime mission (July 2004 through January 2007).

  11. Verification and validation benchmarks

    International Nuclear Information System (INIS)

    Oberkampf, William Louis; Trucano, Timothy Guy

    2007-01-01

    Verification and validation (V and V) are the primary means to assess the accuracy and reliability of computational simulations. V and V methods and procedures have fundamentally improved the credibility of simulations in several high-consequence fields, such as nuclear reactor safety, underground nuclear waste storage, and nuclear weapon safety. Although the terminology is not uniform across engineering disciplines, code verification deals with assessing the reliability of the software coding, and solution verification deals with assessing the numerical accuracy of the solution to a computational model. Validation addresses the physics modeling accuracy of a computational simulation by comparing the computational results with experimental data. Code verification benchmarks and validation benchmarks have been constructed for a number of years in every field of computational simulation. However, no comprehensive guidelines have been proposed for the construction and use of V and V benchmarks. For example, the field of nuclear reactor safety has not focused on code verification benchmarks, but it has placed great emphasis on developing validation benchmarks. Many of these validation benchmarks are closely related to the operations of actual reactors at near-safety-critical conditions, as opposed to being more fundamental-physics benchmarks. This paper presents recommendations for the effective design and use of code verification benchmarks based on manufactured solutions, classical analytical solutions, and highly accurate numerical solutions. In addition, this paper presents recommendations for the design and use of validation benchmarks, highlighting the careful design of building-block experiments, the estimation of experimental measurement uncertainty for both inputs and outputs to the code, validation metrics, and the role of model calibration in validation. It is argued that the understanding of predictive capability of a computational model is built on the

  12. Verification and validation benchmarks

    International Nuclear Information System (INIS)

    Oberkampf, William L.; Trucano, Timothy G.

    2008-01-01

    Verification and validation (V and V) are the primary means to assess the accuracy and reliability of computational simulations. V and V methods and procedures have fundamentally improved the credibility of simulations in several high-consequence fields, such as nuclear reactor safety, underground nuclear waste storage, and nuclear weapon safety. Although the terminology is not uniform across engineering disciplines, code verification deals with assessing the reliability of the software coding, and solution verification deals with assessing the numerical accuracy of the solution to a computational model. Validation addresses the physics modeling accuracy of a computational simulation by comparing the computational results with experimental data. Code verification benchmarks and validation benchmarks have been constructed for a number of years in every field of computational simulation. However, no comprehensive guidelines have been proposed for the construction and use of V and V benchmarks. For example, the field of nuclear reactor safety has not focused on code verification benchmarks, but it has placed great emphasis on developing validation benchmarks. Many of these validation benchmarks are closely related to the operations of actual reactors at near-safety-critical conditions, as opposed to being more fundamental-physics benchmarks. This paper presents recommendations for the effective design and use of code verification benchmarks based on manufactured solutions, classical analytical solutions, and highly accurate numerical solutions. In addition, this paper presents recommendations for the design and use of validation benchmarks, highlighting the careful design of building-block experiments, the estimation of experimental measurement uncertainty for both inputs and outputs to the code, validation metrics, and the role of model calibration in validation. It is argued that the understanding of predictive capability of a computational model is built on the

  13. CD45{sup low}c-Kit{sup high} cells have hematopoietic properties in the mouse aorta-gonad-mesonephros region

    Energy Technology Data Exchange (ETDEWEB)

    Nobuhisa, Ikuo, E-mail: nobuhisa.scr@mri.tmd.ac.jp [Department of Stem Cell Regulation, Medical Research Institute, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510 (Japan); Department of Cell Fate Modulation, Institute of Molecular Embryology and Genetics/Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto, 860-0811 (Japan); Yamasaki, Shoutarou [Department of Cell Fate Modulation, Institute of Molecular Embryology and Genetics/Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto, 860-0811 (Japan); Ramadan, Ahmed [Department of Stem Cell Regulation, Medical Research Institute, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510 (Japan); Department of Cell Fate Modulation, Institute of Molecular Embryology and Genetics/Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto, 860-0811 (Japan); Taga, Tetsuya, E-mail: taga.scr@mri.tmd.ac.jp [Department of Stem Cell Regulation, Medical Research Institute, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510 (Japan); Department of Cell Fate Modulation, Institute of Molecular Embryology and Genetics/Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto, 860-0811 (Japan)

    2012-04-01

    Long-term reconstituting hematopoietic stem cells first arise from the aorta of the aorta-gonad-mesonephros (AGM) region in a mouse embryo. We have previously reported that in cultures of the dispersed AGM region, CD45{sup low}c-Kit{sup +} cells possess the ability to reconstitute multilineage hematopoietic cells, but investigations are needed to show that this is not a cultured artifact and to clarify when and how this population is present. Based on the expression profile of CD45 and c-Kit in freshly dissociated AGM cells from embryonic day 9.5 (E9.5) to E12.5 and aorta cells in the AGM from E13.5 to E15.5, we defined six cell populations (CD45{sup -}c-Kit{sup -}, CD45{sup -}c-Kit{sup low}, CD45{sup -}c-Kit{sup high}, CD45{sup low}c-Kit{sup high}, CD45{sup high}c-Kit{sup high}, and CD45{sup high}c-Kit{sup very} {sup low}). Among these six populations, CD45{sup low}c-Kit{sup high} cells were most able to form hematopoietic cell colonies, but their ability decreased after E11.5 and was undetectable at E13.5 and later. The CD45{sup low}c-Kit{sup high} cells showed multipotency in vitro. We demonstrated further enrichment of hematopoietic activity in the Hoechst dye-effluxing side population among the CD45{sup low}c-Kit{sup high} cells. Here, we determined that CD45{sup low}c-Kit{sup high} cells arise from the lateral plate mesoderm using embryonic stem cell-derived differentiation system. In conclusion, CD45{sup low}c-Kit{sup high} cells are the major hematopoietic cells of mouse AGM.

  14. Kits para aerossol em um serviço de saúde: uma análise microbiológica após reprocessamento Kits para aerosol en un servicio de salud: un análisis microbiológico post procesamiento Aerosol kits in a health service: a post-processing microbiologic analysis

    Directory of Open Access Journals (Sweden)

    Patrícia Staciarini Anders

    2008-06-01

    Full Text Available Kits para aerossol são artigos utilizados na terapêutica de afecções do trato respiratório e requerem no mínimo desinfecção de nível intermediário para reuso. Os objetivos deste estudo foram verificar uma possível contaminação microbiana em kits para aerossol pós-reprocessamento e identificar os microrganismos isolados. Estudo transversal, experimental realizado na unidade pediátrica de um hospital em Goiânia-GO. Coletaram-se amostras de três segmentos (máscara, copo, interior da extensão de 15 kits previamente desinfetados, que foram semeadas em diferentes meios de culturas e os microrganismos isolados foram identificados por provas bioquímicas. Dos 15 kits analisados, 13 copos, nove extensões e 13 máscaras estavam contaminados. Isolou-se no total 101 UFC, 39 provindos dos copos, 20 das extensões e 42 das máscaras. Dentre os patógenos isolados destaca-se: Staphylococcus coagulase positivo, Staphylococcus coagulase negativo, Bastonetes Gram negativo fermentadores, Bastonetes Gram negativo não fermentadores, micrococose leveduras. A detecção microbiana indica prováveis falhas no reprocessamento desses artigos.Kits para aerosol son artículos utilizados en la terapéutica de afecciones del tracto respiratorio y requieren en lo mínimo desinfección a nivel intermediario para volver a ser usado. Los objetivos de este estudio fueron verificar una posible contaminación microbiológica en kits para aerosol post-reprocesamiento e identificar los microorganismos aislados. Se trata de un estudio transversal, experimental realizado en la unidad pediátrica de un hospital en Goiânia-GO. Se recolectaron muestras de tres segmentos (máscara, vaso, interior de la extensión de 15 kits previamente desinfectados, que fueron sembradas en diferentes medios de cultivo y los microorganismos aislados fueron identificados por pruebas bioquímicas. De los 15 kits analizados, 13 vasos, nueve extensiones y 13 máscaras estaban contaminados

  15. Quantitative analysis of patient-specific dosimetric IMRT verification

    International Nuclear Information System (INIS)

    Budgell, G J; Perrin, B A; Mott, J H L; Fairfoul, J; Mackay, R I

    2005-01-01

    Patient-specific dosimetric verification methods for IMRT treatments are variable, time-consuming and frequently qualitative, preventing evidence-based reduction in the amount of verification performed. This paper addresses some of these issues by applying a quantitative analysis parameter to the dosimetric verification procedure. Film measurements in different planes were acquired for a series of ten IMRT prostate patients, analysed using the quantitative parameter, and compared to determine the most suitable verification plane. Film and ion chamber verification results for 61 patients were analysed to determine long-term accuracy, reproducibility and stability of the planning and delivery system. The reproducibility of the measurement and analysis system was also studied. The results show that verification results are strongly dependent on the plane chosen, with the coronal plane particularly insensitive to delivery error. Unexpectedly, no correlation could be found between the levels of error in different verification planes. Longer term verification results showed consistent patterns which suggest that the amount of patient-specific verification can be safely reduced, provided proper caution is exercised: an evidence-based model for such reduction is proposed. It is concluded that dose/distance to agreement (e.g., 3%/3 mm) should be used as a criterion of acceptability. Quantitative parameters calculated for a given criterion of acceptability should be adopted in conjunction with displays that show where discrepancies occur. Planning and delivery systems which cannot meet the required standards of accuracy, reproducibility and stability to reduce verification will not be accepted by the radiotherapy community

  16. SeqKit: A Cross-Platform and Ultrafast Toolkit for FASTA/Q File Manipulation.

    Directory of Open Access Journals (Sweden)

    Wei Shen

    Full Text Available FASTA and FASTQ are basic and ubiquitous formats for storing nucleotide and protein sequences. Common manipulations of FASTA/Q file include converting, searching, filtering, deduplication, splitting, shuffling, and sampling. Existing tools only implement some of these manipulations, and not particularly efficiently, and some are only available for certain operating systems. Furthermore, the complicated installation process of required packages and running environments can render these programs less user friendly. This paper describes a cross-platform ultrafast comprehensive toolkit for FASTA/Q processing. SeqKit provides executable binary files for all major operating systems, including Windows, Linux, and Mac OSX, and can be directly used without any dependencies or pre-configurations. SeqKit demonstrates competitive performance in execution time and memory usage compared to similar tools. The efficiency and usability of SeqKit enable researchers to rapidly accomplish common FASTA/Q file manipulations. SeqKit is open source and available on Github at https://github.com/shenwei356/seqkit.

  17. Post-silicon and runtime verification for modern processors

    CERN Document Server

    Wagner, Ilya

    2010-01-01

    The purpose of this book is to survey the state of the art and evolving directions in post-silicon and runtime verification. The authors start by giving an overview of the state of the art in verification, particularly current post-silicon methodologies in use in the industry, both for the domain of processor pipeline design and for memory subsystems. They then dive into the presentation of several new post-silicon verification solutions aimed at boosting the verification coverage of modern processors, dedicating several chapters to this topic. The presentation of runtime verification solution

  18. Composition of lyophilized kit for radiopharmaceutical 99mTc-DTPA

    International Nuclear Information System (INIS)

    Kovacheva, S.P.; Bychvarova, K.A.; Donev, T.N.

    1988-01-01

    The composition finds application for functional radioisotope studies of kidneys and brain. The radiopharmaceuticals, obtained from lyophilized kit with this composition possess a high radiochemical purity, long shelf life and minimal content of reduced hydrolised technetium. They are stable in vivo and in vitro and ensure high quality of examinations at low body background. The composition of the lyophilized kit is based on diethylenetriaminepentaacetic acid, tin dichloride dihydrate and ascorbic acid accordingly in relation 61:1:1 and concentrations 10.4 mg, 0.17 mg and 0.17 mg. 1 cl

  19. An evaluation of the Ramco kit for serum ferritin assay

    International Nuclear Information System (INIS)

    Dempster, W.S.; Knight, G.J.; Jacobs, P.

    1979-01-01

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6μg/l to greater than 2 000 μg/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice

  20. Cell type-specific deficiency of c-kit gene expression in mutant mice of mi/mi genotype.

    Science.gov (United States)

    Isozaki, K.; Tsujimura, T.; Nomura, S.; Morii, E.; Koshimizu, U.; Nishimune, Y.; Kitamura, Y.

    1994-01-01

    The mi locus of mice encodes a novel member of the basic-helix-loop-helix-leucine zipper protein family of transcription factors (hereafter called mi factor). In addition to microphthalmus, osteopetrosis, and lack of melanocytes, mice of mi/mi genotype are deficient in mast cells. Since the c-kit receptor tyrosine kinase plays an important role in the development of mast cells, and since the c-kit expression by cultured mast cells from mi/mi mice is deficient in both mRNA and protein levels, the mast cell deficiency of mi/mi mice has been attributed at least in part to the deficient expression of c-kit. However, it remained to be examined whether the c-kit expression was also deficient in tissues of mi/mi mice. In the present study, we examined the c-kit expression by mi/mi skin mast cells using in situ hybridization and immunohistochemistry. Moreover, we examined the c-kit expression by various cells other than mast cells in tissues of mi/mi mice. We found that the c-kit expression was deficient in mast cells but not in erythroid precursors, testicular germ cells, and neurons of mi/mi mice. This suggested that the regulation of the c-kit transcription by the mi factor was dependent on cell types. Mice of mi/mi genotype appeared to be a useful model to analyze the function of transcription factors in the whole-animal level. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:7524330

  1. Verification and the safeguards legacy

    International Nuclear Information System (INIS)

    Perricos, Demetrius

    2001-01-01

    A number of inspection or monitoring systems throughout the world over the last decades have been structured drawing upon the IAEA experience of setting up and operating its safeguards system. The first global verification system was born with the creation of the IAEA safeguards system, about 35 years ago. With the conclusion of the NPT in 1968, inspections were to be performed under safeguards agreements, concluded directly between the IAEA and non-nuclear weapon states parties to the Treaty. The IAEA developed the safeguards system within the limitations reflected in the Blue Book (INFCIRC 153), such as limitations of routine access by the inspectors to 'strategic points', including 'key measurement points', and the focusing of verification on declared nuclear material in declared installations. The system, based as it was on nuclear material accountancy. It was expected to detect a diversion of nuclear material with a high probability and within a given time and therefore determine also that there had been no diversion of nuclear material from peaceful purposes. The most vital element of any verification system is the inspector. Technology can assist but cannot replace the inspector in the field. Their experience, knowledge, intuition and initiative are invaluable factors contributing to the success of any inspection regime. The IAEA inspectors are however not part of an international police force that will intervene to prevent a violation taking place. To be credible they should be technically qualified with substantial experience in industry or in research and development before they are recruited. An extensive training program has to make sure that the inspectors retain their professional capabilities and that it provides them with new skills. Over the years, the inspectors and through them the safeguards verification system gained experience in: organization and management of large teams; examination of records and evaluation of material balances

  2. From smells to stories : The design and evaluation of the smell memory kit

    NARCIS (Netherlands)

    Leret, Susana Camara; Visch, V.T.

    2017-01-01

    The study presented is a research through design of the motivational, story sharing effects of smell, within the context of addiction care. This investigation led to the co-design of the Smell Memory Kit: a kit using eight selected smells as motivational elements to evoke and share

  3. Press kit kicks off new branding.

    Science.gov (United States)

    Rees, Tom

    2004-01-01

    A smartly produced press kit resulted in unprecedented news coverage when Denver's Porter Adventist Hospital recently unveiled plans for an extensive 80 million dollars redevelopment. A news conference was held to announce this plan, along with the opening of the hospital's new emergency department. The overall effort is part of the new branding strategy of the 75-year-old hospital.

  4. A novel kit for rapid detection of Vibrio cholerae O1.

    OpenAIRE

    Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R

    1994-01-01

    We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bact...

  5. RESRAD-BUILD verification

    International Nuclear Information System (INIS)

    Kamboj, S.; Yu, C.; Biwer, B. M.; Klett, T.

    2002-01-01

    The results generated by the RESRAD-BUILD code (version 3.0) were verified with hand or spreadsheet calculations using equations given in the RESRAD-BUILD manual for different pathways. For verification purposes, different radionuclides--H-3, C-14, Na-22, Al-26, Cl-36, Mn-54, Co-60, Au-195, Ra-226, Ra-228, Th-228, and U-238--were chosen to test all pathways and models. Tritium, Ra-226, and Th-228 were chosen because of the special tritium and radon models in the RESRAD-BUILD code. Other radionuclides were selected to represent a spectrum of radiation types and energies. Verification of the RESRAD-BUILD code was conducted with an initial check of all the input parameters for correctness against their original source documents. Verification of the calculations was performed external to the RESRAD-BUILD code with Microsoft Excel to verify all the major portions of the code. In some cases, RESRAD-BUILD results were compared with those of external codes, such as MCNP (Monte Carlo N-particle) and RESRAD. The verification was conducted on a step-by-step basis and used different test cases as templates. The following types of calculations were investigated: (1) source injection rate, (2) air concentration in the room, (3) air particulate deposition, (4) radon pathway model, (5) tritium model for volume source, (6) external exposure model, (7) different pathway doses, and (8) time dependence of dose. Some minor errors were identified in version 3.0; these errors have been corrected in later versions of the code. Some possible improvements in the code were also identified

  6. Fundamental and clinical evaluation of vasoactive intestinal peptide (VIP) in pancreatitis by radioimmunoassay kit

    International Nuclear Information System (INIS)

    Uehara, Soichiro; Nakamura, Takayuki; Ihara, Kenichi; Isogawa, Shin; Hirayama, Akio

    1987-01-01

    Plasma vasoactive intestinal peptide (VIP) concentrations of normal individuals and patients with pancreatitis were studied using a VIP RIA kit. The inter-assay and intra-assay variation of this kit were between 2.1 and 9.4 %. The VIP levels increased in the acute phase of acute pancreatitis and patients with chronic pancreatitis. The VIP concentration increased during the first 30 min of glucose tolerance test, but this increase was much smaller than that in insulin. These results suggest that this kit is useful for physiologic and pathologic changes in the VIP level. (author)

  7. Feasibility of fractionating MIBI cold kits for cost reduction

    Energy Technology Data Exchange (ETDEWEB)

    Penglis, S.; Tsopelas, C. [Royal Adelaide Hospital. SA (Australia)

    1998-06-01

    Full text: Recently {sup 99m}Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of {sup 99m}Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N{sub 2} atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  8. Feasibility of fractionating MIBI cold kits for cost reduction

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1998-01-01

    Full text: Recently 99m Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of 99m Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N 2 atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation

  9. Spent fuel verification options for final repository safeguards in Finland. A study on verification methods, their feasibility and safety aspects

    International Nuclear Information System (INIS)

    Hautamaeki, J.; Tiitta, A.

    2000-12-01

    The verification possibilities of the spent fuel assemblies from the Olkiluoto and Loviisa NPPs and the fuel rods from the research reactor of VTT are contemplated in this report. The spent fuel assemblies have to be verified at the partial defect level before the final disposal into the geologic repository. The rods from the research reactor may be verified at the gross defect level. Developing a measurement system for partial defect verification is a complicated and time-consuming task. The Passive High Energy Gamma Emission Tomography and the Fork Detector combined with Gamma Spectrometry are the most potential measurement principles to be developed for this purpose. The whole verification process has to be planned to be as slick as possible. An early start in the planning of the verification and developing the measurement devices is important in order to enable a smooth integration of the verification measurements into the conditioning and disposal process. The IAEA and Euratom have not yet concluded the safeguards criteria for the final disposal. E.g. criteria connected to the selection of the best place to perform the verification. Measurements have not yet been concluded. Options for the verification places have been considered in this report. One option for a verification measurement place is the intermediate storage. The other option is the encapsulation plant. Crucial viewpoints are such as which one offers the best practical possibilities to perform the measurements effectively and which would be the better place in the safeguards point of view. Verification measurements may be needed both in the intermediate storages and in the encapsulation plant. In this report also the integrity of the fuel assemblies after wet intermediate storage period is assessed, because the assemblies have to stand the handling operations of the verification measurements. (orig.)

  10. Indoor Air Quality Tools for Schools Action Kit

    Science.gov (United States)

    The IAQ Tools for Schools Action Kit provides schools with information on how to carry out a practical plan to improve indoor air problems at little- or no-cost using straightforward activities and in-house staff.

  11. Formulation of DOTATATE Cold Kit for Preparation of Ga-68 Radiopharmaceutical

    International Nuclear Information System (INIS)

    Sriwiang, W.; Duangta, T.; Kaeopookum, P.; Wongsanit, S.

    2014-01-01

    Radiolabeled somatostatin analogs of peptide receptors targeting tumor cells have become a common practice in the diagnosis and treatment of certain types of cancer. The aim of this research was to develop the cold kit to be label with Ga-68 radionuclide for neuroendocrine tumor imaging. DOTATATE peptide for somatostatin receptor was formulated with NaOAc and ascorbic acid into lyophilized form. Radiochemical purity (RCP) of 68 Ga-DOTATATE labeled complex prepared from the cold kit was determined during storage period of 5 months and evaluated before clinical application to EANM guideline. The %RCP of the labeled peptide was more than 95% throughout period of storage with Ge-68 breakthrough less than 0.001%. The peptide content calculated from peak area of standard DOTATATE calibration curve using HPLC at uv 220 nm was found to be 15.3±4.62 μg. The specific activity of 68 Ga-DOTATATE, which depended on activities eluted from generator, was 34.7 - 52 MBq/nmol-peptide. The pH of the Ga-68 radiopharmaceutical kit after dilution with phosphate-buffered saline was 5.0 - 5.3. These results demonstrated that preparing of 68 Ga-DOTATATE radiopharmaceutical from lyophilized kit presented in this study was suitable and convenient method obtaining high radiochemical purity of short half-life Ga-68 radionuclide.

  12. Nanobody-derived nanobiotechnology tool kits for diverse biomedical and biotechnology applications.

    Science.gov (United States)

    Wang, Yongzhong; Fan, Zhen; Shao, Lei; Kong, Xiaowei; Hou, Xianjuan; Tian, Dongrui; Sun, Ying; Xiao, Yazhong; Yu, Li

    2016-01-01

    Owing to peculiar properties of nanobody, including nanoscale size, robust structure, stable and soluble behaviors in aqueous solution, reversible refolding, high affinity and specificity for only one cognate target, superior cryptic cleft accessibility, and deep tissue penetration, as well as a sustainable source, it has been an ideal research tool for the development of sophisticated nanobiotechnologies. Currently, the nanobody has been evolved into versatile research and application tool kits for diverse biomedical and biotechnology applications. Various nanobody-derived formats, including the nanobody itself, the radionuclide or fluorescent-labeled nanobodies, nanobody homo- or heteromultimers, nanobody-coated nanoparticles, and nanobody-displayed bacteriophages, have been successfully demonstrated as powerful nanobiotechnological tool kits for basic biomedical research, targeting drug delivery and therapy, disease diagnosis, bioimaging, and agricultural and plant protection. These applications indicate a special advantage of these nanobody-derived technologies, already surpassing the "me-too" products of other equivalent binders, such as the full-length antibodies, single-chain variable fragments, antigen-binding fragments, targeting peptides, and DNA-based aptamers. In this review, we summarize the current state of the art in nanobody research, focusing on the nanobody structural features, nanobody production approach, nanobody-derived nanobiotechnology tool kits, and the potentially diverse applications in biomedicine and biotechnology. The future trends, challenges, and limitations of the nanobody-derived nanobiotechnology tool kits are also discussed.

  13. Embryonic and foetal Islet-1 positive cells in human hearts are also positive to c-Kit

    Directory of Open Access Journals (Sweden)

    C. Serradifalco

    2011-12-01

    Full Text Available During embryogenesis, the mammalian heart develops from a primitive heart tube originating from two bilateral primary heart fields located in the lateral plate mesoderm. Cells belongings to the pre-cardiac mesoderm will differentiate into early cardiac progenitors, which express early transcription factors which are also common to the Isl-1 positive cardiac progenitor cells isolated from the developing pharyngeal mesoderm and the foetal and post-natal mice hearts. A second population of cardiac progenitor cells positive to c-Kit has been abundantly isolated from adult hearts. Until now, these two populations have been considered two different sets of progenitor cells present in the heart in different stages of an individual life. In the present study we collected embryonic, foetal and infant hearts, and we tested the hypotheses that c-Kit positive cells, usually isolated from the adult heart, are also present in the intra-uterine life and persist in the adult heart after birth, and that foetal Isl-1 positive cells are also positive to c-Kit. Using immunohistochemistry we studied the temporal distribution of Isl-1 positive and c-Kit/CD105 double positive cells, and by immunofluorescence and confocal analysis we studied the co-localization of c-Kit and Isl-1 positive cells. The results indicated that cardiomyocytes and interstitial cells were positive for c-Kit from the 9th to the 19th gestational week, that cells positive for both c-Kit and CD105 appeared in the interstitium at the 17th gestational week and persisted in the postnatal age, and that the Isl-1 positive cells were a subset of the c-Kit positive population.

  14. Inhibition of c-Kit signaling is associated with reduced heat and cold pain sensitivity in humans.

    Science.gov (United States)

    Ceko, Marta; Milenkovic, Nevena; le Coutre, Philipp; Westermann, Jörg; Lewin, Gary R

    2014-07-01

    The tyrosine kinase receptor c-Kit is critically involved in the modulation of nociceptive sensitivity in mice. Ablation of the c-Kit gene results in hyposensitivity to thermal pain, whereas activation of c-Kit produces hypersensitivity to noxious heat, without altering sensitivity to innocuous mechanical stimuli. In this study, we investigated the role of c-Kit signaling in human pain perception. We hypothesized that subjects treated with Imatinib or Nilotinib, potent inhibitors of tyrosine kinases including c-Kit but also Abl1, PDFGFRα, and PDFGFRβ, that are used to treat chronic myeloid leukemia (CML), would experience changes in thermal pain sensitivity. We examined 31 asymptomatic CML patients (14 male and 17 female) receiving Imatinib/Nilotinib treatment and compared them to 39 age- and sex-matched healthy controls (12 male and 27 female). We used cutaneous heat and cold stimulation to test normal and noxious thermal sensitivity, and a grating orientation task to assess tactile acuity. Thermal pain thresholds were significantly increased in the Imatinib/Nilotinib-treated group, whereas innocuous thermal and tactile thresholds were unchanged compared to those in the control group. In conclusion, our findings suggest that the biological effects of c-Kit inhibition are comparable in mice and humans in that c-Kit activity is required to regulate thermal pain sensitivity but does not affect innocuous thermal and mechanical sensation. The effect on experimental heat pain observed in our study is comparable to those of several common analgesics; thus modulation of the c-Kit pathway can be used to specifically modulate noxious heat and cold sensitivity in humans. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  15. Comparison of commercial DNA preparation kits for the detection of Brucellae in tissue using quantitative real-time PCR

    Directory of Open Access Journals (Sweden)

    Straube Eberhard

    2010-04-01

    Full Text Available Abstract Background The detection of Brucellae in tissue specimens using PCR assays is difficult because the amount of bacteria is usually low. Therefore, optimised DNA extraction methods are critical. The aim of this study was to assess the performance of commercial kits for the extraction of Brucella DNA. Methods Five kits were evaluated using clinical specimens: QIAamp™ DNA Mini Kit (QIAGEN, peqGold™ Tissue DNA Mini Kit (PeqLab, UltraClean™ Tissue and Cells DNA Isolation Kit (MoBio, DNA Isolation Kit for Cells and Tissues (Roche, and NucleoSpin™ Tissue (Macherey-Nagel. DNA yield was determined using a quantitative real-time PCR assay targeting IS711 that included an internal amplification control. Results Kits of QIAGEN and Roche provided the highest amount of DNA, Macherey-Nagel and Peqlab products were intermediate whereas MoBio yielded the lowest amount of DNA. Differences were significant (p Conclusions We observed differences in DNA yield as high as two orders of magnitude for some samples between the best and the worst DNA extraction kits and inhibition was observed occasionally. This indicates that DNA purification may be more relevant than expected when the amount of DNA in tissue is very low.

  16. Pharmacological targeting of the KIT growth factor receptor: a therapeutic consideration for mast cell disorders

    DEFF Research Database (Denmark)

    Jensen, Bettina Margrethe; Akin, C; Gilfillan, A M

    2008-01-01

    within these tissues, mast cell activation by antigen may also be amplified by SCF. Thus, KIT inhibitors may have potential application in multiple conditions linked to mast cells including systemic mastocytosis, anaphylaxis, and asthma. In this review, we discuss the role of KIT in the context of mast...... cells in these disease states and how recent advances in the development of inhibitors of KIT activity and function may offer novel therapies for the treatment of these disorders....

  17. Rapid Characterization of Insulin Modifications and Sequence Variations by Proteinase K Digestion and UHPLC-ESI-MS

    Science.gov (United States)

    Yang, Rong-Sheng; Tang, Weijuan; Sheng, Huaming; Meng, Fanyu

    2018-01-01

    Discovery of novel insulin analogs as therapeutics has remained an active area of research. Compared with native human insulin, insulin analog molecules normally incorporate either covalent modifications or amino acid sequence variations. From the drug discovery and development perspective, methods for efficient and detailed characterization of these primary structural changes are very important. In this report, we demonstrate that proteinase K digestion coupled with UPLC-ESI-MS analysis provides a simple and rapid approach to characterize the modifications and sequence variations of insulin molecules. A commercially available proteinase K digestion kit was used to process recombinant human insulin (RHI), insulin glargine, and fluorescein isothiocynate-labeled recombinant human insulin (FITC-RHI) samples. The LC-MS data clearly showed that RHI and insulin glargine samples can be differentiated, and the FITC modifications in all three amine sites of the RHI molecule are well characterized. The end-to-end experiment and data interpretation was achieved within 60 min. This approach is fast and simple, and can be easily implemented in early drug discovery laboratories to facilitate research on more advanced insulin therapeutics. [Figure not available: see fulltext.

  18. Rapid Characterization of Insulin Modifications and Sequence Variations by Proteinase K Digestion and UHPLC-ESI-MS

    Science.gov (United States)

    Yang, Rong-Sheng; Tang, Weijuan; Sheng, Huaming; Meng, Fanyu

    2018-05-01

    Discovery of novel insulin analogs as therapeutics has remained an active area of research. Compared with native human insulin, insulin analog molecules normally incorporate either covalent modifications or amino acid sequence variations. From the drug discovery and development perspective, methods for efficient and detailed characterization of these primary structural changes are very important. In this report, we demonstrate that proteinase K digestion coupled with UPLC-ESI-MS analysis provides a simple and rapid approach to characterize the modifications and sequence variations of insulin molecules. A commercially available proteinase K digestion kit was used to process recombinant human insulin (RHI), insulin glargine, and fluorescein isothiocynate-labeled recombinant human insulin (FITC-RHI) samples. The LC-MS data clearly showed that RHI and insulin glargine samples can be differentiated, and the FITC modifications in all three amine sites of the RHI molecule are well characterized. The end-to-end experiment and data interpretation was achieved within 60 min. This approach is fast and simple, and can be easily implemented in early drug discovery laboratories to facilitate research on more advanced insulin therapeutics. [Figure not available: see fulltext.

  19. Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2010-01-01

    In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail

  20. Stannous ion quantitation in sup(99m)Tc-radiopharmaceutical kits

    International Nuclear Information System (INIS)

    Chervu, L.R.; Vallabhajosyula, B.; Mani, J.; Chun, S.B.; Blaufox, M.D.

    1982-01-01

    A simple and inexpensive method for the estimation of stannous ion, Sn(II), in radiopharmaceutical kits is described. The method used is a potentiometric titration of Sn(II) in 1 N HCl medium, using potassium iodate as the oxidizing agent in an atmosphere of nitrogen. The apparatus includes a pH meter, a platinum electrode, and a simple titration cell. Several commonly used radiopharmaceutical kits were analyzed for their Sn(II) content using this method. These studies indicate that the procedure can be used, as a routine quantitative test for the Sn(II) content of various sup(99m)Tc-labeled radiopharmaceuticals. (orig.)

  1. Engineering CHO cells with an oncogenic KIT improves cells growth, resilience to stress, and productivity.

    Science.gov (United States)

    Mahameed, Mohamed; Tirosh, Boaz

    2017-11-01

    An optimized biomanufacturing process in mammalian cells is contingent on the ability of the producing cells to reach high viable cell densities. In addition, at the peak of growth, cells need to continue producing the biological entity at a consistent quality. Thus, engineering cells with robust growth performance and resilience to variable stress conditions is highly desirable. The tyrosine kinase receptor, KIT, plays a key role in cell differentiation and the survival of several immune cell types. Its oncogenic mutant, D816V, endows cells with high proliferation capacity, and resistance to kinase inhibitors. Importantly, this onco-KIT mutant when introduced into various cell types is arrested in the endoplasmic reticulum in a constitutively active form. Here, we investigated the effect of oncogenic D816V KIT on the performance of CHO-K1 cells under conventional tissue culture growth settings and when adapted, to shaking conditions. The onco-KIT promoted global protein synthesis, elevated the expression of a secretable transgene, enhanced proliferation, and improved the overall titers of a model glycoprotein. Moreover, the expression of the onco-KIT endowed the cells with a remarkable resistance to various stress conditions. Our data suggest that the introduction of onco-KIT can serve as a strategy for improving glycoprotein biomanufacturing. Biotechnol. Bioeng. 2017;114: 2560-2570. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  2. Evaluation of two different HEDP content kits: Stability study against dilution both in vivo and in vitro

    International Nuclear Information System (INIS)

    Inoue, O.; Ikeda, I.; Kurata, K.

    1982-01-01

    Two different HEDP content kits (Kit A, HEDP: 1 mg, SnCl 2 x 2H 2 O: 0.5 mg; and Kit B, HEDP: 10 mg, SnCl 2 x 2H 2 O: 0.5 mg) were evaluated for their stability against dillution. Sup(99m)Tc-HEDP solutions prepared from these two kits were diluted from 10 to 6000 fold with 0.9% NaCl solution just before evaluation both in vivo and in vitro. In the case of Kit A, significant soft tissue uptake in vivo and released free pertechnetate in vitro were observed by diluting the sup(99m)Tc-HEDP solution. On the other hand, sup(99m)Tc-HEDP prepared from Kit B was found to be sufficiently stable against dilution. The stability after preparation of each diluted sup(99m)-HEDP was also greatly affected by its HEDP concentration. Preliminary analysis of absorption spectra for each 99 Tc-HEDP indicated the possibility of two different sup(99m)Tc-HEDP complex formation by varied HEDP concentration. These results indicated that a cold reagent like Kit A might cause a higher soft tissue uptake due to its dilution in vivo during a clinical study for bone scanning. (orig.) [de

  3. Structural basis for c-KIT inhibition by the suppressor of cytokine signaling 6 (SOCS6) ubiquitin ligase

    DEFF Research Database (Denmark)

    Zadjali, Fahad; Pike, Ashley C W; Vesterlund, Mattias

    2011-01-01

    to substrate residue position pY+6 and envelopes the c-KIT phosphopeptide with a large BG loop insertion that contributes significantly to substrate interaction. We demonstrate that SOCS6 has ubiquitin ligase activity toward c-KIT and regulates c-KIT protein turnover in cells. Our data support a role of SOCS6...

  4. Verification of safety critical software

    International Nuclear Information System (INIS)

    Son, Ki Chang; Chun, Chong Son; Lee, Byeong Joo; Lee, Soon Sung; Lee, Byung Chai

    1996-01-01

    To assure quality of safety critical software, software should be developed in accordance with software development procedures and rigorous software verification and validation should be performed. Software verification is the formal act of reviewing, testing of checking, and documenting whether software components comply with the specified requirements for a particular stage of the development phase[1]. New software verification methodology was developed and was applied to the Shutdown System No. 1 and 2 (SDS1,2) for Wolsung 2,3 and 4 nuclear power plants by Korea Atomic Energy Research Institute(KAERI) and Atomic Energy of Canada Limited(AECL) in order to satisfy new regulation requirements of Atomic Energy Control Boars(AECB). Software verification methodology applied to SDS1 for Wolsung 2,3 and 4 project will be described in this paper. Some errors were found by this methodology during the software development for SDS1 and were corrected by software designer. Outputs from Wolsung 2,3 and 4 project have demonstrated that the use of this methodology results in a high quality, cost-effective product. 15 refs., 6 figs. (author)

  5. Future of monitoring and verification

    International Nuclear Information System (INIS)

    Wagenmakers, H.

    1991-01-01

    The organized verification entrusted to IAEA for the implementation of the NPT, of the Treaty of Tlatelolco and of the Treaty of Rarotonga, reaches reasonable standards. The current dispute with the Democratic People's Republic of Korea about the conclusion of a safeguards agreement with IAEA, by its exceptional nature, underscores rather than undermines the positive judgement to be passed on IAEA's overall performance. The additional task given to the Director General of IAEA under Security Council resolution 687 (1991) regarding Iraq's nuclear-weapons-usable material is particularly challenging. For the purposes of this paper, verification is defined as the process for establishing whether the States parties are complying with an agreement. In the final stage verification may lead into consideration of how to respond to non-compliance. Monitoring is perceived as the first level in the verification system. It is one generic form of collecting information on objects, activities or events and it involves a variety of instruments ranging from communications satellites to television cameras or human inspectors. Monitoring may also be used as a confidence-building measure

  6. 3D vision upgrade kit for TALON robot

    Science.gov (United States)

    Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Pezzaniti, J. Larry; Chenault, David B.; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Pettijohn, Brad

    2010-04-01

    In this paper, we report on the development of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. The 3D vision system was integrated onto a TALON IV Robot and Operator Control Unit (OCU) such that stock components could be electrically disconnected and removed, and upgrade components coupled directly to the mounting and electrical connections. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.

  7. Community-Based Colorectal Cancer Screening in a Rural Population: Who Returns Fecal Immunochemical Test (FIT) Kits?

    Science.gov (United States)

    Crosby, Richard A; Stradtman, Lindsay; Collins, Tom; Vanderpool, Robin

    2017-09-01

    To determine the return rate of community-delivered fecal immunochemical test (FIT) kits in a rural population and to identify significant predictors of returning kits. Residents were recruited in 8 rural Kentucky counties to enroll in the study and receive an FIT kit. Of 345 recruited, 82.0% returned an FIT kit from the point of distribution. These participants were compared to the remainder relative to age, sex, marital status, having an annual income below $15,000, not graduating from high school, not having a regular health care provider, not having health care coverage, being a current smoker, indicating current overweight or obese status, and a scale measure of fatalism pertaining to colorectal cancer. Predictors achieving significance at the bivariate level were entered into a stepwise logistic regression model to calculate adjusted OR and 95% CI. The return rate was 82.0%. In adjusted analyses, those indicating an annual income of less than $15,000 were 2.85 times more likely to return their kits (95% CI: 1.56-5.24; P < .001). Also, those not perceiving themselves to be overweight/obese were 1.95 times more likely to return their kits (95% CI: 1.07-3.55; P = .029). An outreach-based colorectal cancer screening program in a rural population may yield high return rates. People with annual incomes below $15,000 and those not having perceptions of being overweight/obese may be particularly likely to return FIT kits. © 2016 National Rural Health Association.

  8. Verification Image of The Veins on The Back Palm with Modified Local Line Binary Pattern (MLLBP) and Histogram

    Science.gov (United States)

    Prijono, Agus; Darmawan Hangkawidjaja, Aan; Ratnadewi; Saleh Ahmar, Ansari

    2018-01-01

    The verification to person who is used today as a fingerprint, signature, personal identification number (PIN) in the bank system, identity cards, attendance, easily copied and forged. This causes the system not secure and is vulnerable to unauthorized persons to access the system. In this research will be implemented verification system using the image of the blood vessels in the back of the palms as recognition more difficult to imitate because it is located inside the human body so it is safer to use. The blood vessels located at the back of the human hand is unique, even humans twins have a different image of the blood vessels. Besides the image of the blood vessels do not depend on a person’s age, so it can be used for long term, except in the case of an accident, or disease. Because of the unique vein pattern recognition can be used in a person. In this paper, we used a modification method to perform the introduction of a person based on the image of the blood vessel that is using Modified Local Line Binary Pattern (MLLBP). The process of matching blood vessel image feature extraction using Hamming Distance. Test case of verification is done by calculating the percentage of acceptance of the same person. Rejection error occurs if a person was not matched by the system with the data itself. The 10 person with 15 image compared to 5 image vein for each person is resulted 80,67% successful Another test case of the verification is done by verified two image from different person that is forgery, and the verification will be true if the system can rejection the image forgery. The ten different person is not verified and the result is obtained 94%.

  9. Determination of plasma adrenaline and noradrenaline levels with the Cat-a-Kit

    International Nuclear Information System (INIS)

    Nel, P.B.; Du Preez, S.E.

    1980-01-01

    A method for the determination of catecholamines (Cat-a-Kit; Upjohn Diagnostics) is discussed. It depends upon the enzymatic conversion of the catecholamines to their ring o-methylated analogues in the presence of s-adenosyl-L-methionine-methyl- 14 C and catechol-o-methyltransferase. Values obtained from the blood plasma of 16 tetraplegic and 11 healthy volunteers are reported. The advantages and disadvantages of the Cat-a-Kit are discussed

  10. Prolonged expression of the c-kit receptor in germ cells of intersex fetal testes

    DEFF Research Database (Denmark)

    Rajpert-De Meyts, Ewa; Jørgensen, N; Müller, Jørn

    1996-01-01

    conditions which included 45,X/46,XY mosaicism; androgen insensitivity syndrome; and 46,XY/iso(p)Y mosaicism. Individuals with such disorders of sexual differentiation and Y-chromosome material carry a very high risk of developing testicular neoplasms. Fetal testicular germ cells of the intersex subjects...... expressed Kit at a later developmental age than controls, in which no Kit protein was detectable beyond the 15th week of gestation. This finding may indicate a disturbance of the chronology of germ cell development, or it may suggest a change of the regulation of c-kit expression in subjects with disorders...

  11. The preparation and clinical use of a radioimmunoassay CA125 kit for the diagnosis of epithelial ovarian cancer

    International Nuclear Information System (INIS)

    Liu Wenshu

    1992-01-01

    A self-made radioimmunoassay CA125 kit (using OC125 monoclonal antibody ascites offered by Dr. Bast Laboratory which was purified, solidified and labelled with 125 I) was used for serum determination in 80 patients with epithelial ovarian cancer and in 40 standard antigen samples. The results demonstrated a statistically significant correlation between our self-made CA 125 kit and an imported CENTOCOR CA125 kit (P 125 kit is very useful in monitoring epithelial ovarian cancer

  12. Concepts for inventory verification in critical facilities

    International Nuclear Information System (INIS)

    Cobb, D.D.; Sapir, J.L.; Kern, E.A.; Dietz, R.J.

    1978-12-01

    Materials measurement and inventory verification concepts for safeguarding large critical facilities are presented. Inspection strategies and methods for applying international safeguards to such facilities are proposed. The conceptual approach to routine inventory verification includes frequent visits to the facility by one inspector, and the use of seals and nondestructive assay (NDA) measurements to verify the portion of the inventory maintained in vault storage. Periodic verification of the reactor inventory is accomplished by sampling and NDA measurement of in-core fuel elements combined with measurements of integral reactivity and related reactor parameters that are sensitive to the total fissile inventory. A combination of statistical sampling and NDA verification with measurements of reactor parameters is more effective than either technique used by itself. Special procedures for assessment and verification for abnormal safeguards conditions are also considered. When the inspection strategies and inventory verification methods are combined with strict containment and surveillance methods, they provide a high degree of assurance that any clandestine attempt to divert a significant quantity of fissile material from a critical facility inventory will be detected. Field testing of specific hardware systems and procedures to determine their sensitivity, reliability, and operational acceptability is recommended. 50 figures, 21 tables

  13. Verification and Examination Management of Complex Systems

    Directory of Open Access Journals (Sweden)

    Stian Ruud

    2014-10-01

    Full Text Available As ship systems become more complex, with an increasing number of safety-critical functions, many interconnected subsystems, tight integration to other systems, and a large amount of potential failure modes, several industry parties have identified the need for improved methods for managing the verification and examination efforts of such complex systems. Such needs are even more prominent now that the marine and offshore industries are targeting more activities and operations in the Arctic environment. In this paper, a set of requirements and a method for verification and examination management are proposed for allocating examination efforts to selected subsystems. The method is based on a definition of a verification risk function for a given system topology and given requirements. The marginal verification risks for the subsystems may then be evaluated, so that examination efforts for the subsystem can be allocated. Two cases of requirements and systems are used to demonstrate the proposed method. The method establishes a systematic relationship between the verification loss, the logic system topology, verification method performance, examination stop criterion, the required examination effort, and a proposed sequence of examinations to reach the examination stop criterion.

  14. Monitoring and verification R and D

    International Nuclear Information System (INIS)

    Pilat, Joseph F.; Budlong-Sylvester, Kory W.; Fearey, Bryan L.

    2011-01-01

    The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R and D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R and D required to address these gaps and other monitoring and verification challenges.

  15. Resveratrol Improves Cell Cycle Arrest in Chronic Prostatitis Rats, by C-kit/SCF Suppression.

    Science.gov (United States)

    He, Yi; Zeng, Huizhi; Yu, Yang; Zhang, Jiashu; Zeng, Xiaona; Gong, Fengtao; Liu, Qi; Yang, Bo

    2017-08-01

    Chronic prostatitis (CP) with complex pathogenesis is difficult for treatment. c-kit has been associated with the control of cell proliferation of prostate cells. This study aims to evaluate the role of resveratrol, an activator of Sirt1, in regulating the expression of c-kit in CP and investigate the consequent effects on cell cycle. Rat model of CP was established through subcutaneous injections of diphtheria-pertussis-tetanus vaccine and subsequently treated with resveratrol. Hematoxylin and eosin staining was performed to identify the histopathological changes in prostates. Western blotting and immunohistochemical staining examined the expression level of c-kit, stem cell factor (SCF), Sirt1, and cell cycle-associated proteins. The model group exhibited severe diffuse chronic inflammation, characterized by leukocyte infiltration and papillary frond protrusion into the gland cavities, and a notable increase in prostatic epithelial height. Gland lumen diameter was also significantly smaller; the activity of c-kit/SCF in the CP rats was increased significantly compared to the control group. Meanwhile, the cell cycle proteins are dysregulated significantly in CP rats. Resveratrol treatment significantly improved these factors by Sirt1 activation. Dysregulation of cell cycle was involved in the pathological processes of CP, which was improved after resveratrol treatment by the downregulation of c-kit/SCF by activating Sirt1.

  16. Salisphere derived c-Kit+ cell transplantation restores tissue homeostasis in irradiated salivary gland

    International Nuclear Information System (INIS)

    Nanduri, Lalitha S.Y.; Lombaert, Isabelle M.A.; Zwaag, Marianne van der; Faber, Hette; Brunsting, Jeanette F.; Os, Ronald P. van; Coppes, Robert P.

    2013-01-01

    Introduction: During radiotherapy salivary glands of head and neck cancer patients are unavoidably co-irradiated, potentially resulting in life-long impairment. Recently we showed that transplantation of salisphere-derived c-Kit expressing cells can functionally regenerate irradiated salivary glands. This study aims to select a more potent subpopulation of c-Kit + cells, co-expressing stem cell markers and to investigate whether long-term tissue homeostasis is restored after stem cell transplantation. Methods and results: Salisphere derived c-Kit + cells that co-expressed CD24 and/or CD49f markers, were intra-glandularly injected into 15 Gy irradiated submandibular glands of mice. Particularly, c-Kit + /CD24 + /CD49f + cell transplanted mice improved saliva production (54.59 ± 11.1%) versus the irradiated control group (21.5 ± 8.7%). Increase in expression of cells with differentiated duct cell markers like, cytokeratins (CK8, 18, 7 and 14) indicated functional recovery of this compartment. Moreover, ductal stem cell marker expression like c-Kit, CD133, CD24 and CD49f reappeared after transplantation indicating long-term functional maintenance potential of the gland. Furthermore, a normalization of vascularization as indicated by CD31 expression and reduction of fibrosis was observed, indicative of normalization of the microenvironment. Conclusions: Our results show that stem cell transplantation not only rescues hypo-salivation, but also restores tissue homeostasis of the irradiated gland, necessary for long-term maintenance of adult tissue

  17. Cross-site comparison of ribosomal depletion kits for Illumina RNAseq library construction.

    Science.gov (United States)

    Herbert, Zachary T; Kershner, Jamie P; Butty, Vincent L; Thimmapuram, Jyothi; Choudhari, Sulbha; Alekseyev, Yuriy O; Fan, Jun; Podnar, Jessica W; Wilcox, Edward; Gipson, Jenny; Gillaspy, Allison; Jepsen, Kristen; BonDurant, Sandra Splinter; Morris, Krystalynne; Berkeley, Maura; LeClerc, Ashley; Simpson, Stephen D; Sommerville, Gary; Grimmett, Leslie; Adams, Marie; Levine, Stuart S

    2018-03-15

    Ribosomal RNA (rRNA) comprises at least 90% of total RNA extracted from mammalian tissue or cell line samples. Informative transcriptional profiling using massively parallel sequencing technologies requires either enrichment of mature poly-adenylated transcripts or targeted depletion of the rRNA fraction. The latter method is of particular interest because it is compatible with degraded samples such as those extracted from FFPE and also captures transcripts that are not poly-adenylated such as some non-coding RNAs. Here we provide a cross-site study that evaluates the performance of ribosomal RNA removal kits from Illumina, Takara/Clontech, Kapa Biosystems, Lexogen, New England Biolabs and Qiagen on intact and degraded RNA samples. We find that all of the kits are capable of performing significant ribosomal depletion, though there are differences in their ease of use. All kits were able to remove ribosomal RNA to below 20% with intact RNA and identify ~ 14,000 protein coding genes from the Universal Human Reference RNA sample at >1FPKM. Analysis of differentially detected genes between kits suggests that transcript length may be a key factor in library production efficiency. These results provide a roadmap for labs on the strengths of each of these methods and how best to utilize them.

  18. Utilization of milk amino acids for body gain in suckling mink (Mustela vison) kits

    DEFF Research Database (Denmark)

    Tauson, Anne-Helene; Fink, Rikke; Hansen, Niels E

    2005-01-01

    The efficiency of utilization of milk amino acids for body gain in suckling mink kits from small (n = 3), medium (n = 6) and large litters (n = 9) was investigated by using 36 mink dams and their litters for measurements during lactation weeks 1 through 4. Measurements on each dam and litter were...... performed once, hence three dams per litter size each week (n = 9). Individual milk intake of kits was determined, milk samples were collected and kits were killed for determination of amino acid composition. The most abundant amino acids in milk were glutamate, leucine and aspartate making up about 40......% of total amino acids. Branched chained amino acids made up slightly more than 20% and sulphur containing amino acids less than 5% of total milk amino acids. In kit bodies the sum of glutamate, aspartate and leucine made up about 32% of amino acids, branched chain amino acids about 16% and sulphur...

  19. Preparation and evaluation of freeze-dried Mag3 kits for 99m Tc-labelling

    International Nuclear Information System (INIS)

    El-Mohty, A.A.; El-Ghany, E.A.; El-Kolaly, M.T.; Raieh, M.; EL-Bary, A.A.

    1996-01-01

    The freeze-dried Mag 3 kits were designed for both ligand trans chelation and direct labelling techniques. The solution of Sn-Mag 3 was sterilized by 0.22 μU mill pore filtration and dispensed in a laminar flow hood (1 m I / vial) then, the vials were introduced to the lyophilized. The process of lyophilization was continued for 24 hours. At end of the cycle, the vials were closed under nitrogen. The moisture content of the freeze-dried Mag 3 kits was determined and it was found equal to 0.1% also, the losses of tin (II) during the freeze-drying cycle did not exceed 5%. It was found that the Mag 3 freeze-dried kits were sterile, pyrogen free and does not have any unexpected toxicity. The prepared Mag 3 freeze-dried kits have high radiochemical purity > 97% and high stability for more than 8 h after labelling. The biodistribution shows rapid renal excretion at 15 min post injection. 3 figs., 4 tabs

  20. Use of monoclonal immunoradiometric assays for sensitive TSH measurements: evaluation of four commercially obtainable kits

    International Nuclear Information System (INIS)

    Smitz, J.; Schiettecatte, J.; Stierteghem, A.C. van; Jonckheer, M.H.

    1987-01-01

    Four commerically available monoclonal immunoradiometric methods for the assay of TSH are tested. These four kits are: RIA-GNOST TSH code 0CPL of Behring, SUCROSEP TSH IRMA of Boots, TSH-IRMA-CT-100 of Medgenix, TSH-RIA bead II Ultrasensitive of Abbott. The accuracy, sensitivity and reproducibility of the four kits are compared. The methods are also clinically evaluated. The authors concluded that the kits of Abbott, Behring and Boots are suitable for use in the routine laboratory. 4 refs.; 4 figs.; 7 tabs

  1. Nationwide study of factors associated with public's willingness to use home self-test kit for dengue fever in Malaysia.

    Science.gov (United States)

    Wong, Li Ping; Atefi, Narges; AbuBakar, Sazaly

    2016-08-12

    As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1) identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2) find out the characteristics of the test kits that influence the use of the dengue test kit. A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18-60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43-0.89; p = 0.02, vs. tertiary educational level) and secondary educational levels (OR: 0.73; 95 % CI: 0.57-0.90; p = 0.01, vs. tertiary educational level) were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0-5) were less likely (OR: 0.67, 95 % CI: 0.53-0.85, p dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10). Participants with a lower total dengue fever knowledge score (range 0-22) were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61-0.91, p = 0.001, vs. higher total dengue fever knowledge score) compared to those with a higher total dengue fever knowledge score (range 23-44). With response to

  2. Assessment of RFID Read Accuracy for ISS Water Kit

    Science.gov (United States)

    Chu, Andrew

    2011-01-01

    The Space Life Sciences Directorate/Medical Informatics and Health Care Systems Branch (SD4) is assessing the benefits Radio Frequency Identification (RFID) technology for tracking items flown onboard the International Space Station (ISS). As an initial study, the Avionic Systems Division Electromagnetic Systems Branch (EV4) is collaborating with SD4 to affix RFID tags to a water kit supplied by SD4 and studying the read success rate of the tagged items. The tagged water kit inside a Cargo Transfer Bag (CTB) was inventoried using three different RFID technologies, including the Johnson Space Center Building 14 Wireless Habitat Test Bed RFID portal, an RFID hand-held reader being targeted for use on board the ISS, and an RFID enclosure designed and prototyped by EV4.

  3. Using a commercially available DNA extraction kit to obtain high quality human genomic DNA suitable for PCR and genotyping from 11-year-old saliva saturated cotton spit wads

    Directory of Open Access Journals (Sweden)

    Hudziak James J

    2008-12-01

    Full Text Available Abstract Background We sought to describe the integrity of human genomic DNA extracted from saliva saturated cotton spit wads stored at -20°C for approximately 11 years. 783 spit wad samples were collected from an ADHD sample population (Vermont Family Study during 1996–2000. Human genomic DNA was extracted from the spit wads using a commercially available kit; QIAamp DNA Blood Midi Kit (Qiagen, Inc., Valencia, CA. with a few modifications. Results The resulting DNA yield was more than adequate for genetic analysis and ranged from approximately 1 μg to a total of 80 μg (mean 17.3 μgs ± 11.9 μgs. A260/A280 ratios for the human genomic DNA extracted from the spit wads was consistently within the generally acceptable values of 1.7–2.0, with the lowest purity being 1.70, and a mean value of 1.937 ± 0.226 for the 783 samples. The DNA also was suitable for PCR reactions as evidenced by the amplification of the serotonin-transporter-linked polymorphic region, 5HTTLPR. 5HTTLPR is a functional polymorphism in the promoter region of the serotonin transporter gene (HTT, SLC6A4, or SERT, consisting of two intensively studied alleles. 770 of the 783 samples (98.3% produced fragments after PCR of the expected size with primers specific for 5HTTLPR. Conclusion High quality and abundant genomic DNA can be successfully retrieved from saliva saturated cotton spit wads using the commercially available kit, QIAamp DNA Blood Midi Kit from Qiagen, Inc. Furthermore, the DNA can be extracted in less than 3 hours and multiple samples can be processed simultaneously thus reducing processing time.

  4. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    Science.gov (United States)

    Knopf, A.; Parodi, K.; Paganetti, H.; Cascio, E.; Bonab, A.; Bortfeld, T.

    2008-08-01

    scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  5. Quantitative assessment of the physical potential of proton beam range verification with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Knopf, A; Paganetti, H; Cascio, E; Bortfeld, T [Department of Radiation Oncology, MGH and Harvard Medical School, Boston, MA 02114 (United States); Parodi, K [Heidelberg Ion Therapy Center, Heidelberg (Germany); Bonab, A [Department of Radiology, MGH and Harvard Medical School, Boston, MA 02114 (United States)

    2008-08-07

    PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  6. Quantitative assessment of the physical potential of proton beam range verification with PET/CT.

    Science.gov (United States)

    Knopf, A; Parodi, K; Paganetti, H; Cascio, E; Bonab, A; Bortfeld, T

    2008-08-07

    PET scanner. PET/CT range verification was found to be able to detect small range modifications in the presence of complex tissue inhomogeneities. This study indicates the physical potential of the PET/CT verification method to detect the full-range characteristic of the delivered dose in the patient.

  7. Estimation of plasma cortisol by radiocompetition or radioimmunoassay. Use of commercial kits

    International Nuclear Information System (INIS)

    Rymer, J.C.

    1978-01-01

    The estimation of plasma cortisol is carried out in daily practice by numerous laboratories. The use of commercial kits permits a specific, sure and relatively precise estimation. Two kits are studied; the results obtained are compared with those given by a method of measurement of fluorescence. Economic assessment together with estimation of the risks due to manipulation of radioactive substances permit one to judge the relative values of these methods of analysis [fr

  8. Omid Early Intervention Resource Kit for Children with Autism Spectrum Disorders and Their Families

    Science.gov (United States)

    Samadi, Sayyed Ali; Mahmoodizadeh, Ameneh

    2014-01-01

    Omid early intervention resource kit containing information booklets on autism spectrum disorders (ASD) and related issues, five packs of tangible selected playthings and communication facilitating aids was developed and evaluated with 65 Iranian parents. Beside a pretest before the resource kit deliverance, parents in the control group took part…

  9. Minimizing the Threat of Light Pollution on Observatories through Education: the Quality Lighting Teaching Kit

    Science.gov (United States)

    Walker, Constance E.; M, Pompea, Stephen

    2018-01-01

    Poor quality lighting impedes astronomy research and our right to see a starry night sky. It creates safety issues, affects human circadian sensitivities, disrupts ecosystems, and wastes billions of dollars/year in energy consumption. It also leads to excess carbon emissions. How do you change the mindset of society that is used to turning night into day? You educate the next generation on quality lighting.As an outcome of the International Year of Light 2015, the National Optical Astronomy Observatory’s Education and Public Outreach group has produced a Quality Lighting Teaching (QLT) Kit. The kits are designed around problem-based learning scenarios. The kit’s six activities allow students to address real lighting problems that relate to wildlife, sky glow, aging eyes, energy consumption, safety, and light trespass. The activities are optimized for 11-14 year olds but can be expanded to younger and older. All materials are in both English and Spanish. Most of the activities can be done within in a few minutes during class or afterschool and as stations or as stand-alones. Everything you need for the six activities is included in the kit. Tutorial videos on how to do the activities can be found at www.noao.edu/education/qltkit.php. Ninety-two out of one hundred kits have been distributed in thirty-two countries through SPIE (the International Society for Optical Engineering), CIE (the International Commission on Illuminations), OSA (the Optical Society), IDA (the International Dark Sky Association), and the IAU OAD–Office of Astronomy Development. Successful feedback is promoting a choice between commercializing the kit or gaining further grants to build more kits. A plan is being considered to distribute kits to observatories around the world, hence helping to reduce the effects of one of the three threats to observational astronomy through awareness and action.

  10. Inter-laboratory assessment of a prototype multiplex kit for determination of recent HIV-1 infection.

    Directory of Open Access Journals (Sweden)

    Kelly A Curtis

    Full Text Available BACKGROUND: Accurate and reliable laboratory-based assays are needed for estimating HIV-1 incidence from cross-sectional samples. We recently described the development of a customized, HIV-1-specific Bio-Plex assay that allows for the measurement of HIV-specific antibody levels and avidity to multiple analytes for improved HIV-1 incidence estimates. METHODS: To assess intra- and inter-laboratory assay performance, prototype multiplex kits were developed and evaluated by three distinct laboratories. Longitudinal seroconversion specimens were tested in parallel by each laboratory and kit performance was compared to that of an in-house assay. Additionally, the ability of the kit to distinguish recent from long-term HIV-1 infection, as compared to the in-house assay, was determined by comparing the reactivity of known recent (infected 12 months drug naïve specimens. RESULTS: Although the range of reactivity for each analyte varied between the prototype kit and in-house assay, a measurable distinction in reactivity between recent and long-term specimens was observed with both assays in all three laboratories. Additionally, kit performance was consistent between all three laboratories. The intra-assay coefficient of variation (CV, between sample replicates for all laboratories, ranged from 0.5% to 6.1%. The inter-laboratory CVs ranged from 8.5% to 21.3% for gp160-avidity index (a and gp120-normalized mean fluorescent intensity (MFI value (n, respectively. CONCLUSION: We demonstrate the feasibility of producing a multiplex kit for measuring HIV antibody levels and avidity, with the potential for improved incidence estimates based on multi-analyte algorithms. The availability of a commercial kit will facilitate the transfer of technology among diverse laboratories for widespread assay use.

  11. Face Verification for Mobile Personal Devices

    NARCIS (Netherlands)

    Tao, Q.

    2009-01-01

    In this thesis, we presented a detailed study of the face verification problem on the mobile device, covering every component of the system. The study includes face detection, registration, normalization, and verification. Furthermore, the information fusion problem is studied to verify face

  12. Gender Verification of Female Olympic Athletes.

    Science.gov (United States)

    Dickinson, Barry D.; Genel, Myron; Robinowitz, Carolyn B.; Turner, Patricia L.; Woods, Gary L.

    2002-01-01

    Gender verification of female athletes has long been criticized by geneticists, endocrinologists, and others in the medical community. Recently, the International Olympic Committee's Athletic Commission called for discontinuation of mandatory laboratory-based gender verification of female athletes. This article discusses normal sexual…

  13. Monitoring acetylcholinesterase levels in migrant agricultural workers and their children using a portable test kit.

    Science.gov (United States)

    Higgins, G M; Muñiz, J F; McCauley, L A

    2001-02-01

    The EQM Research, Inc., portable test kit was evaluated as a surveillance tool for blood cholinesterase levels among migrant workers and their children. Laboratory validation demonstrated a linear relationship between the reference Ellman and kit methods (Ellman = 0.95 x kit result + 0.82, r2 = 0.98). Pre- and post-season cholinesterase levels measured in 70 farm workers were within normal ranges, but significantly different at 28.5 and 29.7 U/g Hb, respectively (paired t-test, p = 0.014). Results from 98 migrant farm worker children and a comparison group of 53 age-matched non-agricultural children showed that cholinesterase levels were not significantly different between the agricultural and non-agricultural children (ANOVA, p = 0.69). These data demonstrate that a portable test kit can provide useful data pesticide exposures when measurements are made in a temperature-controlled setting.

  14. Reload core safety verification

    International Nuclear Information System (INIS)

    Svetlik, M.; Minarcin, M.

    2003-01-01

    This paper presents a brief look at the process of reload core safety evaluation and verification in Slovak Republic. It gives an overview of experimental verification of selected nuclear parameters in the course of physics testing during reactor start-up. The comparison of IAEA recommendations and testing procedures at Slovak and European nuclear power plants of similar design is included. An introduction of two level criteria for evaluation of tests represents an effort to formulate the relation between safety evaluation and measured values (Authors)

  15. The structural insights of stem cell factor receptor (c-Kit interaction with tyrosine phosphatase-2 (Shp-2: An in silico analysis

    Directory of Open Access Journals (Sweden)

    Gurudutta Gangenahalli U

    2010-01-01

    Full Text Available Abstract Background Stem cell factor (SCF receptor c-Kit is recognized as a key signaling molecule, which transduces signals for the proliferation, differentiation and survival of stem cells. Binding of SCF to its receptor triggers transactivation, leading to the recruitment of kinases and phosphatases to the docking platforms of c-Kit catalytic domain. Tyrosine phosphatase-1 (Shp-1 deactivates/attenuates 'Kit' kinase activity. Whereas, Asp816Val mutation in the Kit activation loop transforms kinase domain to a constitutively activated state (switch off-to-on state, in a ligand-independent manner. This phenomenon completely abrogates negative regulation of Shp-1. To predict the possible molecular basis of interaction between c-Kit and Shp-1, we have performed an in silico protein-protein docking study between crystal structure of activated c-Kit (phosphorylated c-Kit and full length crystal structure of Shp-2, a close structural counterpart of Shp-1. Findings Study revealed a stretch of conserved amino acids (Lys818 to Ser821 in the Kit activation domain, which makes decisive H-bonds with N-sh2 and phosphotyrosine binding pocket residues of the phosphatase. These H-bonds may impose an inhibitory steric hindrance to the catalytic domain of c-Kit, there by blocking further interaction of the activation loop molecules with incoming kinases. We have also predicted a phosphotyrosine binding pocket in SH2 domains of Shp-1, which is found to be predominantly closer to a catalytic groove like structure in c-Kit kinase domain. Conclusions This study predicts that crucial hydrogen bonding between N-sh2 domain of Shp-1 and Kit activation loop can modulate the negative regulation of c-Kit kinase by Shp-1. Thus, this finding is expected to play a significant role in designing suitable gain-of-function c-Kit mutants for inducing conditional proliferation of hematopoietic stem cells.

  16. Basic and clinical investigation of T3 immunoassay kit

    International Nuclear Information System (INIS)

    Konishi, Junji; Nakajima, Akiko; Morita, Rikushi; Endo, Keigo; Ikekubo, Katsuji

    1976-01-01

    T 3 immunoassay kit was investigated basically and clinically. A good result was obtained at the prescribed incubation temperature and for 16 hours of incubation time. Moreover, it was thought to be possible that incubation time could be shortened to 1 - 4 hours at 37 0 C. Specificity of antibody was good. Recovery of added T 3 was 100+-5 (S.D.) % on an average and parallel of dilution curve of high T 3 serum was also good. Variation coefficient of accuracy of this kit was 1.5 - 2.1 % and that of reproducibility was 1.3 - 6.6 %. Mild hemolysis did not affect measurement value. Serum T 3 level in normals, untreated patients with Basedow's disease and patients with primary hypothyroidism was 142+-21 ng/100 ml, 452+-156 ng/100 ml and 67+-17 ng/100 ml, respectively. Serum T 3 level in patients with Hashimoto's disease was distributed to a wide extent, but that of patients with goiter and simple goiter ranged within normal range. On the other side, serum T 3 level of normal pregnant woman was high and that of patients with anorexia nervosa showed low level. From the above mentioned results, it was concluded that this kit was simple in method and good in sensitivity, specificity and reproducibility and it was also useful for clinical applications. (M. Tsunoda)

  17. Validation of Embedded System Verification Models

    NARCIS (Netherlands)

    Marincic, J.; Mader, Angelika H.; Wieringa, Roelf J.

    The result of a model-based requirements verification shows that the model of a system satisfies (or not) formalised system requirements. The verification result is correct only if the model represents the system adequately. No matter what modelling technique we use, what precedes the model

  18. On Verification Modelling of Embedded Systems

    NARCIS (Netherlands)

    Brinksma, Hendrik; Mader, Angelika H.

    Computer-aided verification of embedded systems hinges on the availability of good verification models of the systems at hand. Such models must be much simpler than full design models or specifications to be of practical value, because of the unavoidable combinatorial complexities in the

  19. MiCroKit 3.0: an integrated database of midbody, centrosome and kinetochore.

    Science.gov (United States)

    Ren, Jian; Liu, Zexian; Gao, Xinjiao; Jin, Changjiang; Ye, Mingliang; Zou, Hanfa; Wen, Longping; Zhang, Zhaolei; Xue, Yu; Yao, Xuebiao

    2010-01-01

    During cell division/mitosis, a specific subset of proteins is spatially and temporally assembled into protein super complexes in three distinct regions, i.e. centrosome/spindle pole, kinetochore/centromere and midbody/cleavage furrow/phragmoplast/bud neck, and modulates cell division process faithfully. Although many experimental efforts have been carried out to investigate the characteristics of these proteins, no integrated database was available. Here, we present the MiCroKit database (http://microkit.biocuckoo.org) of proteins that localize in midbody, centrosome and/or kinetochore. We collected into the MiCroKit database experimentally verified microkit proteins from the scientific literature that have unambiguous supportive evidence for subcellular localization under fluorescent microscope. The current version of MiCroKit 3.0 provides detailed information for 1489 microkit proteins from seven model organisms, including Saccharomyces cerevisiae, Schizasaccharomyces pombe, Caenorhabditis elegans, Drosophila melanogaster, Xenopus laevis, Mus musculus and Homo sapiens. Moreover, the orthologous information was provided for these microkit proteins, and could be a useful resource for further experimental identification. The online service of MiCroKit database was implemented in PHP + MySQL + JavaScript, while the local packages were developed in JAVA 1.5 (J2SE 5.0).

  20. Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.

    Science.gov (United States)

    Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E

    2014-07-26

    Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.

  1. Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate

    DEFF Research Database (Denmark)

    Schou, Toke Munk; Malmkvist, Jens

    2017-01-01

    increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams’ additional maternal behaviour. Therefore, we cannot confirm that temperature is the primary reason for kit mortality, under the conditions of plenty straw access for maternal nest......We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams...... building. Instead, prenatal and/or parturient litter size is the primary factor influencing early kit vitality. The results indicate that the focus should be on litter size and dam welfare around the times of gestation and birth to increase early kit survival in farmed mink....

  2. Compositional verification of real-time systems using Ecdar

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Legay, Axel

    2012-01-01

    We present a specification theory for timed systems implemented in the Ecdar tool. We illustrate the operations of the specification theory on a running example, showing the models and verification checks. To demonstrate the power of the compositional verification, we perform an in depth case study...... of a leader election protocol; Modeling it in Ecdar as Timed input/output automata Specifications and performing both monolithic and compositional verification of two interesting properties on it. We compare the execution time of the compositional to the classical verification showing a huge difference...

  3. Disarmament Verification - the OPCW Experience

    International Nuclear Information System (INIS)

    Lodding, J.

    2010-01-01

    The Chemical Weapons Convention is the only multilateral treaty that bans completely an entire category of weapons of mass destruction under international verification arrangements. Possessor States, i.e. those that have chemical weapons stockpiles at the time of becoming party to the CWC, commit to destroying these. All States undertake never to acquire chemical weapons and not to help other States acquire such weapons. The CWC foresees time-bound chemical disarmament. The deadlines for destruction for early entrants to the CWC are provided in the treaty. For late entrants, the Conference of States Parties intervenes to set destruction deadlines. One of the unique features of the CWC is thus the regime for verifying destruction of chemical weapons. But how can you design a system for verification at military sites, while protecting military restricted information? What degree of assurance is considered sufficient in such circumstances? How do you divide the verification costs? How do you deal with production capability and initial declarations of existing stockpiles? The founders of the CWC had to address these and other challenges in designing the treaty. Further refinement of the verification system has followed since the treaty opened for signature in 1993 and since inspection work was initiated following entry-into-force of the treaty in 1997. Most of this work concerns destruction at the two large possessor States, Russia and the United States. Perhaps some of the lessons learned from the OPCW experience may be instructive in a future verification regime for nuclear weapons. (author)

  4. Verification of Chemical Weapons Destruction

    International Nuclear Information System (INIS)

    Lodding, J.

    2010-01-01

    The Chemical Weapons Convention is the only multilateral treaty that bans completely an entire category of weapons of mass destruction under international verification arrangements. Possessor States, i.e. those that have chemical weapons stockpiles at the time of becoming party to the CWC, commit to destroying these. All States undertake never to acquire chemical weapons and not to help other States acquire such weapons. The CWC foresees time-bound chemical disarmament. The deadlines for destruction for early entrants to the CWC are provided in the treaty. For late entrants, the Conference of States Parties intervenes to set destruction deadlines. One of the unique features of the CWC is thus the regime for verifying destruction of chemical weapons. But how can you design a system for verification at military sites, while protecting military restricted information? What degree of assurance is considered sufficient in such circumstances? How do you divide the verification costs? How do you deal with production capability and initial declarations of existing stockpiles? The founders of the CWC had to address these and other challenges in designing the treaty. Further refinement of the verification system has followed since the treaty opened for signature in 1993 and since inspection work was initiated following entry-into-force of the treaty in 1997. Most of this work concerns destruction at the two large possessor States, Russia and the United States. Perhaps some of the lessons learned from the OPCW experience may be instructive in a future verification regime for nuclear weapons. (author)

  5. Modification of Core Model for KNTC 2 Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Y.K.; Lee, J.G.; Park, J.E.; Bae, S.N.; Chin, H.C. [Korea Electric Power Research Institute, Taejeon (Korea, Republic of)

    1997-12-31

    KNTC 2 simulator was developed in 1986 referencing YGN 1. Since the YGN 1 has changed its fuel cycle to long term cycle(cycle 9), the data such as rod worth, boron worth, moderator temperature coefficient, and etc. of the simulator and those of the YGN 1 became different. To incorporate these changes into the simulator and make the simulator more close to the reference plant, core model upgrade became a necessity. During this research, core data for the simulator was newly generated using APA of the WH. And to make it easy tuning and verification of the key characteristics of the reactor model, PC-Based tool was also developed. And to facilitate later core model upgrade, two procedures-`the Procedures for core characteristic generation` and `the Procedures for core characteristic modification`-were also developed. (author). 16 refs., 22 figs., 1 tab.

  6. A Model for Collaborative Runtime Verification

    NARCIS (Netherlands)

    Testerink, Bas; Bulling, Nils; Dastani, Mehdi

    2015-01-01

    Runtime verification concerns checking whether a system execution satisfies a given property. In this paper we propose a model for collaborative runtime verification where a network of local monitors collaborates in order to verify properties of the system. A local monitor has only a local view on

  7. Astragalus friederikeanus Kit Tan & Zeitlinger (Fabaceae), a new species from south Anatolia, Turkey

    DEFF Research Database (Denmark)

    Tan, Kit; Zeitlinger, Jörg

    2007-01-01

    A new species from south Anatolia, Turkey, Astragalus friederikeanus Kit Tan & Zeitlinger (Fabaceae), is described and illustrated. The diagnostic morphological characters separating it from other members of sect. Onobrychium Boiss. are listed.......A new species from south Anatolia, Turkey, Astragalus friederikeanus Kit Tan & Zeitlinger (Fabaceae), is described and illustrated. The diagnostic morphological characters separating it from other members of sect. Onobrychium Boiss. are listed....

  8. HDM/PASCAL Verification System User's Manual

    Science.gov (United States)

    Hare, D.

    1983-01-01

    The HDM/Pascal verification system is a tool for proving the correctness of programs written in PASCAL and specified in the Hierarchical Development Methodology (HDM). This document assumes an understanding of PASCAL, HDM, program verification, and the STP system. The steps toward verification which this tool provides are parsing programs and specifications, checking the static semantics, and generating verification conditions. Some support functions are provided such as maintaining a data base, status management, and editing. The system runs under the TOPS-20 and TENEX operating systems and is written in INTERLISP. However, no knowledge is assumed of these operating systems or of INTERLISP. The system requires three executable files, HDMVCG, PARSE, and STP. Optionally, the editor EMACS should be on the system in order for the editor to work. The file HDMVCG is invoked to run the system. The files PARSE and STP are used as lower forks to perform the functions of parsing and proving.

  9. Self-verification and contextualized self-views.

    Science.gov (United States)

    Chen, Serena; English, Tammy; Peng, Kaiping

    2006-07-01

    Whereas most self-verification research has focused on people's desire to verify their global self-conceptions, the present studies examined self-verification with regard to contextualized selfviews-views of the self in particular situations and relationships. It was hypothesized that individuals whose core self-conceptions include contextualized self-views should seek to verify these self-views. In Study 1, the more individuals defined the self in dialectical terms, the more their judgments were biased in favor of verifying over nonverifying feedback about a negative, situation-specific self-view. In Study 2, consistent with research on gender differences in the importance of relationships to the self-concept, women but not men showed a similar bias toward feedback about a negative, relationship-specific self-view, a pattern not seen for global self-views. Together, the results support the notion that self-verification occurs for core self-conceptions, whatever form(s) they may take. Individual differences in self-verification and the nature of selfhood and authenticity are discussed.

  10. Verification of RESRAD-build computer code, version 3.1

    International Nuclear Information System (INIS)

    2003-01-01

    RESRAD-BUILD is a computer model for analyzing the radiological doses resulting from the remediation and occupancy of buildings contaminated with radioactive material. It is part of a family of codes that includes RESRAD, RESRAD-CHEM, RESRAD-RECYCLE, RESRAD-BASELINE, and RESRAD-ECORISK. The RESRAD-BUILD models were developed and codified by Argonne National Laboratory (ANL); version 1.5 of the code and the user's manual were publicly released in 1994. The original version of the code was written for the Microsoft DOS operating system. However, subsequent versions of the code were written for the Microsoft Windows operating system. The purpose of the present verification task (which includes validation as defined in the standard) is to provide an independent review of the latest version of RESRAD-BUILD under the guidance provided by ANSI/ANS-10.4 for verification and validation of existing computer programs. This approach consists of a posteriori V and V review which takes advantage of available program development products as well as user experience. The purpose, as specified in ANSI/ANS-10.4, is to determine whether the program produces valid responses when used to analyze problems within a specific domain of applications, and to document the level of verification. The culmination of these efforts is the production of this formal Verification Report. The first step in performing the verification of an existing program was the preparation of a Verification Review Plan. The review plan consisted of identifying: Reason(s) why a posteriori verification is to be performed; Scope and objectives for the level of verification selected; Development products to be used for the review; Availability and use of user experience; and Actions to be taken to supplement missing or unavailable development products. The purpose, scope and objectives for the level of verification selected are described in this section of the Verification Report. The development products that were used

  11. Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits

    Directory of Open Access Journals (Sweden)

    Jacopo Gervasoni

    2013-01-01

    Full Text Available Objective. 25-hydroxyvitamin D2/D3 (25-OHD2/D3 determination is a reliable biomarker for vitamin D status. Liquid chromatography-tandem mass spectrometry was recently proposed as a reference method for vitamin D status evaluation. The aim of this work is to compare two commercial kits (Chromsystems and PerkinElmer for 25-OHD2/D3 determination by our entry level LC-MS/MS. Design and Methods. Chromsystems kit adds an online trap column to an HPLC column and provides atmospheric pressure chemical ionization, isotopically labeled internal standard, and 4 calibrator points. PerkinElmer kit uses a solvent extraction and protein precipitation method. This kit can be used with or without derivatization with, respectively, electrospray and atmospheric pressure chemical ionization. For each analyte, there are isotopically labeled internal standards and 7 deuterated calibrator points. Results. Performance characteristics are acceptable for both methods. Mean bias between methods calculated on 70 samples was 1.9 ng/mL. Linear regression analysis gave an of 0.94. 25-OHD2 is detectable only with PerkinElmer kit in derivatized assay option. Conclusion. Both methods are suitable for routine. Chromsystems kit minimizes manual sample preparation, requiring only protein precipitation, but, with our system, 25-OHD2 is not detectable. PerkinElmer kit without derivatization does not guarantee acceptable performance with our LC-MS/MS system, as sample is not purified online. Derivatization provides sufficient sensitivity for 25-OHD2 detection.

  12. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    Science.gov (United States)

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  13. Profiling soil microbial communities with next-generation sequencing: the influence of DNA kit selection and technician technical expertise.

    Science.gov (United States)

    Soliman, Taha; Yang, Sung-Yin; Yamazaki, Tomoko; Jenke-Kodama, Holger

    2017-01-01

    Structure and diversity of microbial communities are an important research topic in biology, since microbes play essential roles in the ecology of various environments. Different DNA isolation protocols can lead to data bias and can affect results of next-generation sequencing. To evaluate the impact of protocols for DNA isolation from soil samples and also the influence of individual handling of samples, we compared results obtained by two researchers (R and T) using two different DNA extraction kits: (1) MO BIO PowerSoil ® DNA Isolation kit (MO_R and MO_T) and (2) NucleoSpin ® Soil kit (MN_R and MN_T). Samples were collected from six different sites on Okinawa Island, Japan. For all sites, differences in the results of microbial composition analyses (bacteria, archaea, fungi, and other eukaryotes), obtained by the two researchers using the two kits, were analyzed. For both researchers, the MN kit gave significantly higher yields of genomic DNA at all sites compared to the MO kit (ANOVA; P  technicians for thorough microbial analyses and to obtain accurate estimates of microbial diversity.

  14. Chronic Obstructive Pulmonary Disease and Heart Failure Self-Management Kits for Outpatient Transitions of Care.

    Science.gov (United States)

    Boylan, Paul; Joseph, Tina; Hale, Genevieve; Moreau, Cynthia; Seamon, Matthew; Jones, Renee

    2018-03-01

    To develop heart failure (HF) and chronic obstructive pulmonary disease (COPD) self-management kits in an accountable care organization (ACO) to facilitate patients' self-care and prevent hospital readmissions. Pharmacists practice in an outpatient-based ACO. They participate in interprofessional office visits with providers and independently manage maintenance pharmacotherapies. Pharmacists collaborate with an interprofessional team within the ACO including physicians, nurses, case managers, and paramedics. Two commonly encountered diseases are chronic COPD and HF. Reducing preventable readmissions for these conditions are important quality benchmarks and cost-saving strategies. Pharmacists were responsible for developing HF and COPD self-management kits containing patient education materials and prescriptions to facilitate self-care. Prior to kit development, pharmacists performed a literature review to determine the presence of previously published findings on these topics. The interprofessional team continually evaluates the successes and limitations of this initiative. Pharmacists developed training and instructions for ACO allied health professionals in an effort to incorporate the self-management kits in clinical practice. The initial literature search revealed no studies describing the intervention of interest. Innovative programs designed to help reduce preventable readmissions are lacking in primary care. Implementation of the self-management kits was accepted by interprofessional ACO leadership and is currently being integrated into allied health workflow. Patients at risk for having an exacerbation of COPD or HF should receive self-management strategies. Prompt therapy prior to exacerbations reduces hospital admissions and readmissions, speeds recovery, and slows disease progression. Pharmacist-facilitated implementation of self-management kits may be developed by interprofessional health care teams.

  15. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Immunohistochemistry reagents and kits. 864.1860 Section 864.1860 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Biological Stains § 864.1860...

  16. Procedures for Separations within Batches of Values, 1. The Orderly Tool Kit and Some Heuristics

    Science.gov (United States)

    1989-03-01

    separations within batches of values, I. The orderly tool kit and some heuristics by Thu Hoang* and John W. Tukey** *Universite Rene Descartes ...separations with batches of values, . The orderly tool kit and heuristics Thu Hoang* and John W. Tukey** *Universite Rene Descartes Laboratoire de

  17. Applicability of Commercially Available ELISA Kits for the Quantification of Faecal Immunoreactive Corticosterone Metabolites in Mice

    DEFF Research Database (Denmark)

    Abelson, Klas S P; Kalliokoski, Otto; Teilmann, Anne Charlotte

    2016-01-01

    Background: Commercially available ELISA kits are popular among investigators that quantify faecal corticosterone or cortisol metabolites (FCM) for stress assessment in animals. However, in faeces, these assays mainly detect immunoreactive glucocorticoid metabolites. Since different assays contain......: The present study was designed to investigate corticosterone (CORT) in serum and FCM levels in faeces of laboratory mice, as quantified in four different ELISA kits (DRG EIA-4164, Demeditec DEV9922, Enzo ADI-900-097 and Cayman EIA kit 500655). Assay kits were chosen based on the origin of the antibody...... assays, in both groups of mice. In faecal samples, there was no consistent positive correlation between the levels detected in the four assays and the measured concentration of FCM also differed between assays. Conclusion: Whereas commercially available CORT ELISAs are frequently successfully used...

  18. Kit for instant 99mTc labeling of the antimicrobial peptide ubiquicidin 29-41

    International Nuclear Information System (INIS)

    Ferro-Flores, G.; Arteaga de Murphy, C.; Pedraza-Lopez, M.; Palomares-Rodriguez, P.; Melendez-Alafort, L.

    2005-01-01

    The ubiquicidin 29-41 fragment (UBI) is a cationic antimicrobial peptide. An instant kit formulation was developed for the preparation of 99m Tc-UBI 29-41 in high radiochemical yield and its use as an infection imaging agent in humans was evaluated. The components were selected to produce a direct 99m Tc labeling, presumably to the amine groups of Lys and Arg7. 99m Tc-UBI 29-41 obtained from the lyophilized kit showed radiochemical purity of >97% with an average target/non-target ratio of 2.3±0.6 in positive infection sites at 2 hours. Kits were stable at 4 deg C for over 6 months. (author)

  19. A Verification Logic for GOAL Agents

    Science.gov (United States)

    Hindriks, K. V.

    Although there has been a growing body of literature on verification of agents programs, it has been difficult to design a verification logic for agent programs that fully characterizes such programs and to connect agent programs to agent theory. The challenge is to define an agent programming language that defines a computational framework but also allows for a logical characterization useful for verification. The agent programming language GOAL has been originally designed to connect agent programming to agent theory and we present additional results here that GOAL agents can be fully represented by a logical theory. GOAL agents can thus be said to execute the corresponding logical theory.

  20. Aberrant expressions of c-KIT and DOG-1 in mucinous and nonmucinous colorectal carcinomas and relation to clinicopathologic features and prognosis.

    Science.gov (United States)

    Foda, Abd Al-Rahman Mohammad; Mohamed, Mie Ali

    2015-10-01

    c-KIT and DOG-1 are 2 highly expressed proteins in gastrointestinal stromal tumors. Few studies had investigated c-KIT, but not DOG-1, expression in colorectal carcinoma (CRC). This study aims to investigate expressions of c-KIT and DOG-1 in colorectal mucinous carcinoma and nonmucinous carcinoma using manual tissue microarray technique. In this work, we studied tumor tissue specimens from 150 patients with colorectal mucinous (MA) and nonmucinous adenocarcinoma (NMA). High-density manual tissue microarrays were constructed using modified mechanical pencil tip technique, and immunohistochemistry for c-KIT and DOG-1 was done. We found that aberrant c-KIT expression was detected in 12 cases (8%); 6 cases (4%) showed strong expression. Aberrant DOG-1 expression was detected in 15 cases (10%); among them, only 4 cases (2.7%) showed strong expression. Nonmucinous adenocarcinoma showed a significantly high expression of c-KIT, but not DOG-1, than MA. Aberrant c-KIT and DOG-1 expressions were significantly unrelated but were associated with excessive microscopic abscess formation. Neither c-KIT nor DOG-1 expression showed a significant impact on disease-free survival or overall survival. In conclusion, aberrant c-KIT and DOG-1 expressions in CRC are rare events, either in NMA or MA. Nonmucinous adenocarcinoma showed a significantly higher expression of c-KIT, but not DOG-1, than MA. The expressions of both in CRC are significantly unrelated but are associated with microscopic abscess formation. Neither c-KIT nor DOG-1 expression showed a significant impact on disease-free survival or overall survival. So, c-KIT and DOG-1 immunostaining is not a cost-effective method of identifying patients with CRC who may benefit from treatment with tyrosine kinase inhibitors. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Secure optical verification using dual phase-only correlation

    International Nuclear Information System (INIS)

    Liu, Wei; Liu, Shutian; Zhang, Yan; Xie, Zhenwei; Liu, Zhengjun

    2015-01-01

    We introduce a security-enhanced optical verification system using dual phase-only correlation based on a novel correlation algorithm. By employing a nonlinear encoding, the inherent locks of the verification system are obtained in real-valued random distributions, and the identity keys assigned to authorized users are designed as pure phases. The verification process is implemented in two-step correlation, so only authorized identity keys can output the discriminate auto-correlation and cross-correlation signals that satisfy the reset threshold values. Compared with the traditional phase-only-correlation-based verification systems, a higher security level against counterfeiting and collisions are obtained, which is demonstrated by cryptanalysis using known attacks, such as the known-plaintext attack and the chosen-plaintext attack. Optical experiments as well as necessary numerical simulations are carried out to support the proposed verification method. (paper)

  2. Verification of DRAGON: the NXT tracking module

    International Nuclear Information System (INIS)

    Zkiek, A.; Marleau, G.

    2007-01-01

    The version of DRAGON-IST that has been verified for the calculation of the incremental cross sections associated with CANDU reactivity devices is version 3.04Bb that was released in 2001. Since then, various improvements were implemented in the code including the NXT: module that can track assemblies of clusters in 2-D and 3-D geometries. Here we will discuss the verification plan for the NXT: module of DRAGON, illustrate the verification procedure we selected and present our verification results. (author)

  3. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  4. IMLEMENTASI SIMULASI PhET DAN KIT SEDERHANA UNTUK MENGAJARKAN KETERAMPILAN PSIKOMOTOR SISWA PADA POKOK BAHASAN ALAT OPTIK

    Directory of Open Access Journals (Sweden)

    S. Prihatiningtyas

    2013-04-01

    Full Text Available Penelitian ini bertujuan untuk menuntaskan hasil belajar psikomotor fisika siswa dengan penerapan simulasi PhET dan KIT sederhana pada siswa. Hasil penelitian menunjukkan bahwa keterlaksanaan pembelajaran berjalan dengan baik sesuai dengan RPP, hasil psikomotor kelas eksperimen 1 dengan menggunakan simulasi PhET dan kelas eksperimen 2 dengan menggunakan KIT sederhana dapat menuntaskan hasil belajar siswa, serta respon siswa terhadap pembelajaran positif. Berdasarkan hasil temuan di atas dapat disimpulkan bahwa implementasi simulasi PhET dan KIT sederhana untuk mengajarkan keterampilan psikomotor siswa pada pokok bahasan alat optik dapat menuntaskan hasil belajar psimotor siswa. This study aims to resolve learning outcomes physics psychomotor of students with the application of PhET simulations and simple KIT on students. The results showed that implementation of learning  going well according to the lesson plan, student who are in the experimental class 1 using PhET simulation and the experimental class 2 using a simple KIT could complete the learning outcomes, and student respond to learning was positive. According to the finding above it could be conclude that the implementation PhET simulation and simple KIT to teach psychomotor skills of students on the subject of optical can to complete psychomotor learning outcomes of students.

  5. International Space Station United States Laboratory Module Water Recovery Management Subsystem Verification from Flight 5A to Stage ULF2

    Science.gov (United States)

    Williams, David E.; Labuda, Laura

    2009-01-01

    The International Space Station (ISS) Environmental Control and Life Support (ECLS) system comprises of seven subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), Vacuum System (VS), Water Recovery and Management (WRM), and Waste Management (WM). This paper provides a summary of the nominal operation of the United States (U.S.) Laboratory Module WRM design and detailed element methodologies utilized during the Qualification phase of the U.S. Laboratory Module prior to launch and the Qualification of all of the modification kits added to it from Flight 5A up and including Stage ULF2.

  6. Scientific evaluation of an intra-curricular educational kit to foster inquiry-based learning (IBL)

    Science.gov (United States)

    Debaes, Nathalie; Cords, Nina; Prasad, Amrita; Fischer, Robert; Euler, Manfred; Thienpont, Hugo

    2014-07-01

    Society becomes increasingly dependent on photonics technologies; however there is an alarming lack of technological awareness among secondary school students. They associate photonics with experiments and components in the class room that seem to bear little relevance to their daily life. The Rocard Report [5] highlights the need for fostering students' scientific skills and technological awareness and identifies inquiry based learning (IBL) as a means to achieve this. Students need to actively do science rather than be silent spectators. The `Photonics Explorer' kit was developed as an EU funded project to equip teachers, free-of-charge, with educational material designed to excite, engage and educate European secondary school students using guided inquiry based learning techniques. Students put together their own experiments using up-to-date versatile components, critically interpret results and relate the conclusions to relevant applications in their daily life. They work hands-on with the material, thus developing and honing their scientific and analytical skills that are otherwise latent in a typical class room situation. A qualitative and quantitative study of the impact of the kit in the classroom was undertaken with 50 kits tested in 7 EU countries with over 1500 students in the local language. This paper reports on the results of the EU wide field tests that show the positive impact of the kit in raising the self-efficacy, scientific skills and interest in science among students and the effectiveness of the kit in implementing IBL strategies in classrooms across EU.

  7. Exclusion of EDNRB and KIT as the basis for white spotting in Border Collies.

    Science.gov (United States)

    Metallinos, D; Rine, J

    2000-01-01

    White spotting patterns in mammals can be caused by mutations in the genes for the endothelin B receptor and c-Kit, whose protein products are necessary for proper migration, differentiation or survival of the melanoblast population of cells. Although there are many different dog breeds that segregate white spotting patterns, no genes have been identified that are linked to these phenotypes. An intercross was generated from a female Newfoundland and a male Border Collie and the white spotting phenotypes of the intercross progeny were evaluated by measuring percentage surface area of white in the puppies. The Border Collie markings segregated as a simple autosomal recessive (7/25 intercross progeny had the phenotype). Two candidate genes, for the endothelin B receptor (EDNRB) and c-Kit (KIT), were evaluated for segregation with the white spotting pattern. Polymorphisms between the Border Collie and Newfoundland were identified for EDNRB using Southern analysis after a portion of the canine gene had been cloned. Polymorphisms for KIT were identified using a microsatellite developed from a bacterial artificial chromosome containing the canine gene. Both EDNRB and KIT were excluded as a cause of the white spotting pattern in at least two of the intercross progeny. Although these genes have been implicated in white spotting in other mammals, including horses, pigs, cows, mice and rats, they do not appear to be responsible for the white spotting pattern found in the Border Collie breed of dog.

  8. Technical challenges for dismantlement verification

    International Nuclear Information System (INIS)

    Olinger, C.T.; Stanbro, W.D.; Johnston, R.G.; Nakhleh, C.W.; Dreicer, J.S.

    1997-01-01

    In preparation for future nuclear arms reduction treaties, including any potential successor treaties to START I and II, the authors have been examining possible methods for bilateral warhead dismantlement verification. Warhead dismantlement verification raises significant challenges in the political, legal, and technical arenas. This discussion will focus on the technical issues raised by warhead arms controls. Technical complications arise from several sources. These will be discussed under the headings of warhead authentication, chain-of-custody, dismantlement verification, non-nuclear component tracking, component monitoring, and irreversibility. The authors will discuss possible technical options to address these challenges as applied to a generic dismantlement and disposition process, in the process identifying limitations and vulnerabilities. They expect that these considerations will play a large role in any future arms reduction effort and, therefore, should be addressed in a timely fashion

  9. Safety Verification for Probabilistic Hybrid Systems

    DEFF Research Database (Denmark)

    Zhang, Lijun; She, Zhikun; Ratschan, Stefan

    2010-01-01

    The interplay of random phenomena and continuous real-time control deserves increased attention for instance in wireless sensing and control applications. Safety verification for such systems thus needs to consider probabilistic variations of systems with hybrid dynamics. In safety verification o...... on a number of case studies, tackled using a prototypical implementation....

  10. C-MORE Science Kits: Putting Technology in the Hands of K-12 Teachers and Students

    Science.gov (United States)

    Achilles, K.; Weersing, K.; Daniels, C.; Puniwai, N.; Matsuzaki, J.; Bruno, B. C.

    2008-12-01

    The Center for Microbial Oceanography: Research and Education (C-MORE) is a NSF Science and Technology Center based at the University of Hawaii. The C-MORE education and outreach program offers a variety of resources and professional development opportunities for science educators, including online resources, participation in oceanography research cruises, teacher-training workshops, mini-grants to incorporate microbial oceanography-related content and activities into their classroom and, most recently, C- MORE science kits. C-MORE science kits provide hands-on classroom, field, and laboratory activities related to microbial oceanography for K-12 students. Each kit comes with complete materials and instructions, and is available free of charge to Hawaii's public school teachers. Several kits are available nationwide. C-MORE science kits cover a range of topics and technologies and are targeted at various grade levels. Here is a sampling of some available kits: 1) Marine Murder Mystery: The Case of the Missing Zooxanthellae. Students learn about the effect of climate change and other environmental threats on coral reef destruction through a murder-mystery experience. Participants also learn how to use DNA to identify a suspect. Grades levels: 3-8. 2) Statistical sampling. Students learn basic statistics through an exercise in random sampling, with applications to microbial oceanography. The laptops provided with this kit enable students to enter, analyze, and graph their data using EXCEL. Grades levels: 6-12. 3) Chlorophyll Lab. A research-quality fluorometer is used to measure the chlorophyll content in marine and freshwater systems. This enables students to compare biomass concentrations in samples collected from various locations. Grades levels: 9-12. 4) Conductivity-Temperature-Depth (CTD). Students predict how certain variables (e.g., temperature, pressure, chlorophyll, oxygen) vary with depth. A CTD, attached to a laptop computer, is deployed into deep water

  11. SSN Verification Service

    Data.gov (United States)

    Social Security Administration — The SSN Verification Service is used by Java applications to execute the GUVERF02 service using the WebSphere/CICS Interface. It accepts several input data fields...

  12. Material investigation for manufacturing of reference step gauges for CT scanning verification

    DEFF Research Database (Denmark)

    Cantatore, Angela; Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2012-01-01

    This work deals with the study of stability and material investigation for manufacturing of step gauges for CT scanning verification. Four replica step gauges were fabricated using a bisacryl material for dental applications and the stability over five months was monitored using a tactile CMM....... The material was unstable, probably due to a modification of the chemical composition which lowered the hardness. New step gauges were manufactured through milling. Polyetheretherketone (PEEK) and Polyp-phenylenesulphide (PPS with 40% glass) fulfil the requirements regarding hardness and mechanical properties...... and two series of five step gauges (one series for each material) were manufactured by milling. Results show a significant improvement in terms of form stability and surface geometry quality of the new step gauges with respect to the replica step gauges in Luxabite, as reported below....

  13. Enhanced Verification Test Suite for Physics Simulation Codes

    Energy Technology Data Exchange (ETDEWEB)

    Kamm, J R; Brock, J S; Brandon, S T; Cotrell, D L; Johnson, B; Knupp, P; Rider, W; Trucano, T; Weirs, V G

    2008-10-10

    This document discusses problems with which to augment, in quantity and in quality, the existing tri-laboratory suite of verification problems used by Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). The purpose of verification analysis is demonstrate whether the numerical results of the discretization algorithms in physics and engineering simulation codes provide correct solutions of the corresponding continuum equations. The key points of this document are: (1) Verification deals with mathematical correctness of the numerical algorithms in a code, while validation deals with physical correctness of a simulation in a regime of interest. This document is about verification. (2) The current seven-problem Tri-Laboratory Verification Test Suite, which has been used for approximately five years at the DOE WP laboratories, is limited. (3) Both the methodology for and technology used in verification analysis have evolved and been improved since the original test suite was proposed. (4) The proposed test problems are in three basic areas: (a) Hydrodynamics; (b) Transport processes; and (c) Dynamic strength-of-materials. (5) For several of the proposed problems we provide a 'strong sense verification benchmark', consisting of (i) a clear mathematical statement of the problem with sufficient information to run a computer simulation, (ii) an explanation of how the code result and benchmark solution are to be evaluated, and (iii) a description of the acceptance criterion for simulation code results. (6) It is proposed that the set of verification test problems with which any particular code be evaluated include some of the problems described in this document. Analysis of the proposed verification test problems constitutes part of a necessary--but not sufficient--step that builds confidence in physics and engineering simulation codes. More complicated test cases, including physics models of

  14. Comparative sensitivity and inhibitor tolerance of GlobalFiler® PCR Amplification and Investigator® 24plex QS kits for challenging samples.

    Science.gov (United States)

    Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree

    2018-02-17

    In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Innovative accountability of tracking test kit as locked resources: a lesson in a restricted resource setting.

    Science.gov (United States)

    Makuwani, Ahmad M; Msuya, Sia; Haule, Dunstan; Mogella, Deus; Nkya, Efesper

    2013-09-01

    To implement quality screening in a blood service requires the presence of screening strategy with a clear algorithm and supporting standard operating procedures (SOPs), skilled and motivated human resource to perform testing, infrastructure, regular available test kits, and other supplies. In developing countries, smooth supply chain management of critical transfusion transmissible infections (TTIs) screening reagents is a challenge. Therefore, managing the little available kits by knowing the rate of consumption, good forecasting, and monitoring expiry date may be a key in ensuring regular supply. Test kit monitoring tool (TKMT) for Vironostika HIV Uni-Form kit/192 1&2 Ag/Ab, Genedia kits for HBsAg and HCV, and RPR for syphilis was developed to track these reagents. This excel tool was developed to assess received reagents, quantity used, quantity remaining, and date of expiration. The tool was evaluated by assessing rerun for each test kits, match tests conducted with blood units tested, adherence to the principle of first in-first out (FIFO), and quantity remaining in the center against the need. The mean rerun for HIV ELISA Vironistika uniform II Ag/Ab observed over expected was 6.9% (n = 3.8) than 2.4% (n = 1.3), HBsAg was 9.9% (n = 5.7) than 6.7% (3.5) (expected), Genedia for HCV was 1.3% (n = 0.7) than 0.5% (n = 0.3), and RPR test for syphilis 3.3% (n = 1.5) than 0.5%. During implementation, TKMT managed to detect expiring kits in the zonal blood transfusion centers. A tool-like TKMT may capture other supplies within blood when expanded. Monitoring of supplies may enable blood service actual accounting and in forecasting supplies and reagents. © 2013 Wiley Periodicals, Inc.

  16. Lessons Learned From Microkernel Verification — Specification is the New Bottleneck

    Directory of Open Access Journals (Sweden)

    Thorsten Bormer

    2012-11-01

    Full Text Available Software verification tools have become a lot more powerful in recent years. Even verification of large, complex systems is feasible, as demonstrated in the L4.verified and Verisoft XT projects. Still, functional verification of large software systems is rare – for reasons beyond the large scale of verification effort needed due to the size alone. In this paper we report on lessons learned for verification of large software systems based on the experience gained in microkernel verification in the Verisoft XT project. We discuss a number of issues that impede widespread introduction of formal verification in the software life-cycle process.

  17. Advancing Disarmament Verification Tools: A Task for Europe?

    International Nuclear Information System (INIS)

    Göttsche, Malte; Kütt, Moritz; Neuneck, Götz; Niemeyer, Irmgard

    2015-01-01

    A number of scientific-technical activities have been carried out to establish more robust and irreversible disarmament verification schemes. Regardless of the actual path towards deeper reductions in nuclear arsenals or their total elimination in the future, disarmament verification will require new verification procedures and techniques. This paper discusses the information that would be required as a basis for building confidence in disarmament, how it could be principally verified and the role Europe could play. Various ongoing activities are presented that could be brought together to produce a more intensified research and development environment in Europe. The paper argues that if ‘effective multilateralism’ is the main goal of the European Union’s (EU) disarmament policy, EU efforts should be combined and strengthened to create a coordinated multilateral disarmament verification capacity in the EU and other European countries. The paper concludes with several recommendations that would have a significant impact on future developments. Among other things, the paper proposes a one-year review process that should include all relevant European actors. In the long run, an EU Centre for Disarmament Verification could be envisaged to optimize verification needs, technologies and procedures.

  18. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

    Directory of Open Access Journals (Sweden)

    Rebecca M. Reck

    2016-07-01

    Full Text Available Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC motor and 3D printed parts. The kit has two different configurations. The first (base configuration is a DC motor system with a position and speed sensor. The second configuration adds a Furuta inverted pendulum attachment with another position sensor. These configurations replicate most of the student learning outcomes for the two control systems courses for which they were designed.

  19. Simulation Environment Based on the Universal Verification Methodology

    CERN Document Server

    AUTHOR|(SzGeCERN)697338

    2017-01-01

    Universal Verification Methodology (UVM) is a standardized approach of verifying integrated circuit designs, targeting a Coverage-Driven Verification (CDV). It combines automatic test generation, self-checking testbenches, and coverage metrics to indicate progress in the design verification. The flow of the CDV differs from the traditional directed-testing approach. With the CDV, a testbench developer, by setting the verification goals, starts with an structured plan. Those goals are targeted further by a developed testbench, which generates legal stimuli and sends them to a device under test (DUT). The progress is measured by coverage monitors added to the simulation environment. In this way, the non-exercised functionality can be identified. Moreover, the additional scoreboards indicate undesired DUT behaviour. Such verification environments were developed for three recent ASIC and FPGA projects which have successfully implemented the new work-flow: (1) the CLICpix2 65 nm CMOS hybrid pixel readout ASIC desi...

  20. Evaluation of Two Commercial Enzyme-Linked Immunosorbent Assay Kits for the Detection of Human Circulating Metrnl.

    Science.gov (United States)

    Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu

    2018-04-01

    Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.

  1. Hierarchical Representation Learning for Kinship Verification.

    Science.gov (United States)

    Kohli, Naman; Vatsa, Mayank; Singh, Richa; Noore, Afzel; Majumdar, Angshul

    2017-01-01

    Kinship verification has a number of applications such as organizing large collections of images and recognizing resemblances among humans. In this paper, first, a human study is conducted to understand the capabilities of human mind and to identify the discriminatory areas of a face that facilitate kinship-cues. The visual stimuli presented to the participants determine their ability to recognize kin relationship using the whole face as well as specific facial regions. The effect of participant gender and age and kin-relation pair of the stimulus is analyzed using quantitative measures such as accuracy, discriminability index d' , and perceptual information entropy. Utilizing the information obtained from the human study, a hierarchical kinship verification via representation learning (KVRL) framework is utilized to learn the representation of different face regions in an unsupervised manner. We propose a novel approach for feature representation termed as filtered contractive deep belief networks (fcDBN). The proposed feature representation encodes relational information present in images using filters and contractive regularization penalty. A compact representation of facial images of kin is extracted as an output from the learned model and a multi-layer neural network is utilized to verify the kin accurately. A new WVU kinship database is created, which consists of multiple images per subject to facilitate kinship verification. The results show that the proposed deep learning framework (KVRL-fcDBN) yields the state-of-the-art kinship verification accuracy on the WVU kinship database and on four existing benchmark data sets. Furthermore, kinship information is used as a soft biometric modality to boost the performance of face verification via product of likelihood ratio and support vector machine based approaches. Using the proposed KVRL-fcDBN framework, an improvement of over 20% is observed in the performance of face verification.

  2. BRAF, KIT, NRAS, GNAQ and GNA11 mutation analysis in cutaneous melanomas in Turkish population

    Directory of Open Access Journals (Sweden)

    Ismail Yilmaz

    2015-01-01

    Full Text Available Background: KIT and mitogen-activated protein kinase cascade are important for melanomagenesis. In the present study, we analyzed the frequency of BRAF, NRAS, KIT, GNAQ and GNA11 gene mutations and investigated their association with clinicopathological features of melanomas in Turkish population. Materials and Methods: Forty-seven primary cutaneous melanomas were included in our study. Sanger sequencing method was used for mutation analysis in all cases. Results: Mean age was 62.1 (29-101 years. Female:male ratio was 17:30. Among 47 melanomas, 14 (29.8% BRAF, 10 (21.3% NRAS, 4 (8.5% KIT and 1(2.1% GNAQ gene mutations were detected. Two of the KIT mutations were found in acral lentiginous melanoma (ALM. In the head and neck region, mutation frequency was significantly lower than in other locations (P = 0.035. The only GNAQ gene mutation (p.Q209L was detected in a melanoma arising from blue nevus located on the scalp. None of the melanomas harbored NRAS exon 2, KIT exon 13/17/18, GNAQ exon 4 and GNA11 exon 4/5 mutations. Overall mutation frequency did not show significant difference between metastatic (8/14, 57.1% and nonmetastatic (18/33, 54.5% patients. We did not observe any significant association between mutation status and gender or age of various patients. Conclusions: Our results support that BRAF and NRAS gene mutations are common in cutaneous melanomas. The activating mutations of KIT gene are rare and especially seen in ALM. GNAQ and GNA11 mutations are infrequent in cutaneous melanomas and may be associated only with melanomas arising from blue nevus.

  3. Enhancing Science Kits with the Driving Question Board

    Science.gov (United States)

    Nordine, Jeff; Torres, Ruben

    2013-01-01

    This article describes the driving question board (DQB), a visual organizer that supports inquiry-based instruction through the use of guiding questions. The DQB is a teaching aid designed to increase student engagement alongside science kits. Information is provided on its application to a lesson on buoyancy, highlighting how it improved…

  4. Nationwide study of factors associated with public’s willingness to use home self-test kit for dengue fever in Malaysia

    Directory of Open Access Journals (Sweden)

    Li Ping Wong

    2016-08-01

    Full Text Available Abstract Background As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1 identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2 find out the characteristics of the test kits that influence the use of the dengue test kit. Methods A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18–60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. Results From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43–0.89; p = 0.02, vs. tertiary educational level and secondary educational levels (OR: 0.73; 95 % CI: 0.57–0.90; p = 0.01, vs. tertiary educational level were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0–5 were less likely (OR: 0.67, 95 % CI: 0.53–0.85, p < 0.001, vs. higher perceived barriers to use a home self-testing dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10. Participants with a lower total dengue fever knowledge score (range 0–22 were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61–0.91, p = 0.001, vs. higher total dengue

  5. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

    OpenAIRE

    Rebecca M. Reck; R. S. Sreenivas

    2016-01-01

    Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC ...

  6. Self-verification motives at the collective level of self-definition.

    Science.gov (United States)

    Chen, Serena; Chen, Karen Y; Shaw, Lindsay

    2004-01-01

    Three studies examined self-verification motives in relation to collective aspects of the self. Several moderators of collective self-verification were also examined--namely, the certainty with which collective self-views are held, the nature of one's ties to a source of self-verification, the salience of the collective self, and the importance of group identification. Evidence for collective self-verification emerged across all studies, particularly when collective self-views were held with high certainty (Studies 1 and 2), perceivers were somehow tied to the source of self-verification (Study 1), the collective self was salient (Study 2), and group identification was important (Study 3). To the authors' knowledge, these studies are the first to examine self-verification at the collective level of self-definition. The parallel and distinct ways in which self-verification processes may operate at different levels of self-definition are discussed.

  7. KIT multi-physics tools for the analysis of design and beyond design basis accidents of light water reactors

    International Nuclear Information System (INIS)

    Sanchez, Victor Hugo; Miassoedov, Alexei; Steinbrueck, M.; Tromm, W.

    2016-01-01

    This paper describes the KIT numerical simulation tools under extension and validation for the analysis of design and beyond design basis accidents (DBA) of Light Water Reactors (LWR). The description of the complex thermal hydraulic, neutron kinetics and chemo-physical phenomena going on during off-normal conditions requires the development of multi-physics and multi-scale simulations tools which are fostered by the rapid increase in computer power nowadays. The KIT numerical tools for DBA and beyond DBA are validated using experimental data of KIT or from abroad. The developments, extensions, coupling approaches and validation work performed at KIT are shortly outlined and discussed in this paper.

  8. KIT multi-physics tools for the analysis of design and beyond design basis accidents of light water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Victor Hugo; Miassoedov, Alexei; Steinbrueck, M.; Tromm, W. [Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (Germany)

    2016-05-15

    This paper describes the KIT numerical simulation tools under extension and validation for the analysis of design and beyond design basis accidents (DBA) of Light Water Reactors (LWR). The description of the complex thermal hydraulic, neutron kinetics and chemo-physical phenomena going on during off-normal conditions requires the development of multi-physics and multi-scale simulations tools which are fostered by the rapid increase in computer power nowadays. The KIT numerical tools for DBA and beyond DBA are validated using experimental data of KIT or from abroad. The developments, extensions, coupling approaches and validation work performed at KIT are shortly outlined and discussed in this paper.

  9. Serodiagnosis of chronic Chagas infection by using EIE-Recombinant-Chagas-Biomanguinhos kit

    Directory of Open Access Journals (Sweden)

    Gomes Yara M

    2001-01-01

    Full Text Available A kit based on an enzyme immunoassay, EIE-Recombinant-Chagas-Biomanguinhos, developed by the Oswaldo Cruz Foundation, was evaluated for the serodiagnosis of chronic Chagas disease. Evaluation was performed with 368 serum samples collected from individuals living in an endemic area for Chagas disease: 131 patients in the chronic phase with confirmed clinical, epidemiological, and serological diagnosis (indirect immunofluorescence, indirect hemagglutination or enzyme-linked immunosorbent assay and 237 nonchagasic seronegative individuals were considered negative control. The EIE-Recombinant-Chagas-Biomanguinhos kit showed high sensitivity, 100% (CI 95%: 96.4-100% and high specificity, 100% (CI 95%: 98-100%. The data obtained were in full agreement with clinical and conventional serology data. In addition, no cross-reaction was observed with sera from patients with cutaneous (n=14 and visceral (n=3 leishmaniasis. However, when these sera were tested by conventional serological assays for Chagas disease, cross-reactions were detected in 14.3% and 33.3% of the patients with cutaneous and visceral leishmaniasis, respectively. No cross-reactions were observed when sera from nonchagasic seronegative patients bearing other infectious disease (syphilis, n=8; HTLV, n=8; HCV, n=7 and HBV, n=12 were tested. In addition, sera of patients with inconclusive results for Chagas disease by conventional serology showed results in agreement with clinical evaluation, when tested by the kit. These results are relevant and indicate that the refered kit provides a safe immunodiagnosis of Chagas disease and could be used in blood bank screening.

  10. The application of a multi-physics tool kit to spatial reactor dynamics

    International Nuclear Information System (INIS)

    Clifford, I.; Jasak, H.

    2009-01-01

    Traditionally coupled field nuclear reactor analysis has been carried out using several loosely coupled solvers, each having been developed independently from the others. In the field of multi-physics, the current generation of object-oriented tool kits provides robust close coupling of multiple fields on a single framework. This paper describes the initial results obtained as part of continuing research in the use of the OpenFOAM multi-physics tool kit for reactor dynamics application development. An unstructured, three-dimensional, time-dependent multi-group diffusion code Diffusion FOAM has been developed using the OpenFOAM multi-physics tool kit as a basis. The code is based on the finite-volume methodology and uses a newly developed block-coupled sparse matrix solver for the coupled solution of the multi-group diffusion equations. A description of this code is given with particular emphasis on the newly developed block-coupled solver, along with a selection of results obtained thus far. The code has performed well, indicating that the OpenFOAM tool kit is suited to reactor dynamics applications. This work has shown that the neutronics and simplified thermal-hydraulics of a reactor May be represented and solved for using a common calculation platform, and opens up the possibility for research into robust close-coupling of neutron diffusion and thermal-fluid calculations. This work has further opened up the possibility for research in a number of other areas, including research into three-dimensional unstructured meshes for reactor dynamics applications. (authors)

  11. Runtime Instrumentation of SystemC/TLM2 Interfaces for Fault Tolerance Requirements Verification in Software Cosimulation

    Directory of Open Access Journals (Sweden)

    Antonio da Silva

    2014-01-01

    Full Text Available This paper presents the design of a SystemC transaction level modelling wrapping library that can be used for the assertion of system properties, protocol compliance, or fault injection. The library uses C++ virtual table hooks as a dynamic binary instrumentation technique to inline wrappers in the TLM2 transaction path. This technique can be applied after the elaboration phase and needs neither source code modifications nor recompilation of the top level SystemC modules. The proposed technique has been successfully applied to the robustness verification of the on-board boot software of the Instrument Control Unit of the Solar Orbiter’s Energetic Particle Detector.

  12. 24 CFR 5.512 - Verification of eligible immigration status.

    Science.gov (United States)

    2010-04-01

    ... immigration status. 5.512 Section 5.512 Housing and Urban Development Office of the Secretary, Department of... Noncitizens § 5.512 Verification of eligible immigration status. (a) General. Except as described in paragraph...) Primary verification—(1) Automated verification system. Primary verification of the immigration status of...

  13. Determination of total galactose from dried blood spots—extensive assay evaluation of a CE-marked test-kit

    OpenAIRE

    Fingerhut, R; Torresani, T

    2013-01-01

    Most newborn screening laboratories use CE-marked or FDA-approved test-kits, like in routine clinical chemistry. National regulations require only minimal evaluation from the customer, if the test-kits are used as specified by the manufacturer. The microtiter-based kit-concept is often based on the perception, that the laboratory always processes whole microtiter plates. However, in the daily routine, this is rather a rare exception, which leads to much higher costs per newborn, compared to t...

  14. Verification of RADTRAN

    International Nuclear Information System (INIS)

    Kanipe, F.L.; Neuhauser, K.S.

    1995-01-01

    This document presents details of the verification process of the RADTRAN computer code which was established for the calculation of risk estimates for radioactive materials transportation by highway, rail, air, and waterborne modes

  15. 40 CFR 59.506 - How do I demonstrate compliance if I manufacture multi-component kits?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false How do I demonstrate compliance if I manufacture multi-component kits? 59.506 Section 59.506 Protection of Environment ENVIRONMENTAL PROTECTION... § 59.506 How do I demonstrate compliance if I manufacture multi-component kits? (a) If you manufacture...

  16. PENGEMBANGAN KETERAMPILAN PROSES DAN PEMAHAMAN SISWA KELAS X MELALUI KIT OPTIK

    Directory of Open Access Journals (Sweden)

    - Widayanto

    2011-09-01

    Full Text Available Keterampilan proses sains sangat diperlukan sebagai dasar agar siswa mampu memecahkan masalah. Ketrampilan proses sains dapat dilatihkan melalui kegiatan laboratorium. Dengan memanfaatkan kit optik peneliti bertujuan meningkatkan keterampilan proses sains dan pemahaman materi fisika bagi siswa SMA. Subyek penelitian adalah siswa kelas X-C SMA 3 Sragen tahun ajaran 2006/2007. Hasil penelitian menunjukkan bahwa pemanfaatan kit optik dalam pembelajaran dapat meningkatkan pemahaman dan keterampilan proses sains siswa. Skor rata-rata pemahaman siswa pada siklus I sebesar 73,27 dengan ketuntasan belajar secara  klasikal  sebesar  80,49%,  sedangkan  siklus II  skor  rata-rata  adalah  84,20  dengan  ketuntasan klasikal  sebesar  100%. Sedangkan prosentase rata-rata keterampilan proses sains siswa pada siklus I sebesar 77,37% dan siklus II sebesar 87,36%.The science process skills play an important role as basic for students in solving their problems and can be developed through laboratory activities. By using optical kit, we aim increasing science process skill and understanding physics matter for students. The research subject is X-C Class Senior High School 3 Sragen academic year 2006/2007. The research result show that the use of optical  kit  in  the  learning  can increase  understanding  and  science  process  skill  of students.  The  average  score  of  students understanding at cycle I equals to 73,27 with mastery of learning as much as 80,49%, while that of the cycle II equals to 84,20% with the classically mastery of learning 100%. In addition, the average percentages of students science process skill at cycle I and II are 77,37% and 87,36% respectively© 2009 Jurusan Fisika FMIPA UNNES SemarangKeywords: mastery of learning; optical kit; learning process

  17. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    Science.gov (United States)

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  18. c-Kit-mediated functional positioning of stem cells to their niches is essential for maintenance and regeneration of adult hematopoiesis.

    Directory of Open Access Journals (Sweden)

    Yuki Kimura

    Full Text Available The mechanism by which hematopoietic stem and progenitor cells (HSPCs through interaction with their niches maintain and reconstitute adult hematopoietic cells is unknown. To functionally and genetically track localization of HSPCs with their niches, we employed novel mutant loxPs, lox66 and lox71 and Cre-recombinase technology to conditionally delete c-Kit in adult mice, while simultaneously enabling GFP expression in the c-Kit-deficient cells. Conditional deletion of c-Kit resulted in hematopoietic failure and splenic atrophy both at steady state and after marrow ablation leading to the demise of the treated adult mice. Within the marrow, the c-Kit-expressing GFP(+ cells were positioned to Kit ligand (KL-expressing niche cells. This c-Kit-mediated cellular adhesion was essential for long-term maintenance and expansion of HSPCs. These results lay the foundation for delivering KL within specific niches to maintain and restore hematopoiesis.

  19. Estrogen-induced transcription factor EGR1 regulates c-Kit transcription in the mouse uterus to maintain uterine receptivity for embryo implantation.

    Science.gov (United States)

    Park, Mira; Kim, Hye-Ryun; Kim, Yeon Sun; Yang, Seung Chel; Yoon, Jung Ah; Lyu, Sang Woo; Lim, Hyunjung Jade; Hong, Seok-Ho; Song, Haengseok

    2018-07-15

    Early growth response 1 (Egr1) is a key transcription factor that mediates the action of estrogen (E 2 ) to establish uterine receptivity for embryo implantation. However, few direct target genes of EGR1 have been identified in the uterus. Here, we demonstrated that E 2 induced EGR1-regulated transcription of c-Kit, which plays a crucial role in cell fate decisions. Spatiotemporal expression of c-Kit followed that of EGR1 in uteri of ovariectomized mice at various time points after E 2 treatment. E 2 activated ERK1/2 and p38 to induce EGR1, which then activated c-Kit expression in the uterus. EGR1 transfection produced rapid and transient induction of c-KIT in a time- and dose-dependent manner. Furthermore, luciferase assays to measure c-Kit promoter activity confirmed that a functional EGR1 binding site(s) (EBS) was located within -1 kb of the c-Kit promoter. Site-directed mutagenesis and chromatin immunoprecipitation-PCR for three putative EBS within -1 kb demonstrated that the EBS at -818/-805 was critical for EGR1-dependent c-Kit transcription. c-Kit expression was significantly increased in the uterus on day 4 and administration of Masitinib, a c-Kit inhibitor, effectively interfered with embryo implantation. Collectively, our results showed that estrogen induces transcription factor EGR1 to regulate c-Kit transcription for uterine receptivity for embryo implantation in the mouse uterus. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. c-Kit Expression is Rate-Limiting for Stem Cell Factor-Mediated Disease Progression in Adenoid Cystic Carcinoma of the Salivary Glands

    Directory of Open Access Journals (Sweden)

    Janyaporn Phuchareon

    2014-10-01

    Full Text Available Adenoid cystic carcinoma (ACC is an aggressive malignant neoplasm of the salivary glands in which c-Kit is overexpressed and activated, although the mechanism for this is as yet unclear. We analyzed 27 sporadic ACC tumor specimens to examine the biologic and clinical significance of c-Kit activation. Mutational analysis revealed expression of wild-type c-Kit in all, eliminating gene mutation as a cause of activation. Because stem cell factor (SCF is c-Kit's sole ligand, we analyzed its expression in the tumor cells and their environment. Immunohistochemistry revealed its presence in c-Kit–positive tumor cells, suggesting an activation of autocrine signaling. We observed a significant induction of ERK1/2 in the cells. SCF staining was also found in other types of non-cancerous cells adjacent to tumors within salivary glands, including stromal fibroblasts, neutrophils, peripheral nerve, skeletal muscle, vascular endothelial cells, mucous acinar cells, and intercalated ducts. Quantitative PCR showed that the top quartile of c-Kit mRNA expression distinguished ACCs from normal salivary tissues and was cross-correlated with short-term poor prognosis. Expression levels of SCF and c-Kit were highly correlated in the cases with perineural invasion. These observations suggest that c-Kit is potentially activated by receptor dimerization upon stimulation by SCF in ACC, and that the highest quartile of c-Kit mRNA expression could be a predictor of poor prognosis. Our findings may support an avenue for c-Kit-targeted therapy to improve disease control in ACC patients harboring the top quartile of c-Kit mRNA expression.

  1. Formulation of 68Ga BAPEN kit for myocardial positron emission tomography imaging and biodistribution study

    International Nuclear Information System (INIS)

    Yang, Bo Yeun; Jeong, Jae Min; Kim, Young Joo; Choi, Jae Yeon; Lee, Yun-Sang; Lee, Dong Soo

    2010-01-01

    Introduction: Tris(4,6-dimethoxysalicylaldimine)-N,N'-bis(3-aminopropyl) -N,N'-ethylenediamine (BAPEN), a tris(salicylaldimine) derivative, is a heart positron emission tomography (PET) agent when labeled with 68 Ga. However, its labeling requires complicated and time-consuming procedures. In this study, the authors formulated a new BAPEN kit for convenient 68 Ga labeling. Methods: BAPEN (0.25 mg) kits were prepared by dispensing its solution in 1 M sodium acetate buffer (pH 5.5) into sterile vials and lyophilization. The prepared kits were labeled with generator-eluted 68 Ga in 0.1 N HCl. Stability in human serum was tested. Expiration date was determined by accelerated testing according to US Food and Drug Administration guidelines. A Biodistribution study was performed in normal mice after injection via tail vein. Results: The prepared kits achieved radiolabeling efficiencies in excess of 95% and showed a shelf-life of 98 days at 25 deg. C and 64.3 months at 4 deg. C. 68 Ga-BAPEN was found to be stable in human serum at 37 deg. C for at least 1 h. Furthermore, a biodistribution study revealed high heart uptake (10.8% ID/g, 1 h). Conclusions: The authors developed a BAPEN kit for convenient labeling with 68 Ga. The 68 Ga-BAPEN showed high stability and excellent biodistribution results in normal mice, which is required for myocardial PET imaging.

  2. CASL Verification and Validation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Mousseau, Vincent Andrew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dinh, Nam [North Carolina State Univ., Raleigh, NC (United States)

    2016-06-30

    This report documents the Consortium for Advanced Simulation of LWRs (CASL) verification and validation plan. The document builds upon input from CASL subject matter experts, most notably the CASL Challenge Problem Product Integrators, CASL Focus Area leaders, and CASL code development and assessment teams. This document will be a living document that will track progress on CASL to do verification and validation for both the CASL codes (including MPACT, CTF, BISON, MAMBA) and for the CASL challenge problems (CIPS, PCI, DNB). The CASL codes and the CASL challenge problems are at differing levels of maturity with respect to validation and verification. The gap analysis will summarize additional work that needs to be done. Additional VVUQ work will be done as resources permit. This report is prepared for the Department of Energy’s (DOE’s) CASL program in support of milestone CASL.P13.02.

  3. Diseño del prototipo de un kit de impresora 3D

    OpenAIRE

    Peña García, Sara de la; Cañete Vela, Isabel

    2014-01-01

    Las tecnologías de impresión 3D están experimentando recientemente un gran crecimiento, ganando importancia en diferentes campos de investigación y en el mercado y ampliando la diversidad de sus aplicaciones. Por este motivo, este proyecto consiste en el diseño de un kit de impresora 3D de la mayor calidad posible, mejorando la precisión de los kits actuales. El objetivo principal del proyecto es que esta impresora sea de uso personal, de forma que se traslada un sistema de ...

  4. Effect of using a Planecta™ port with a three-way stopcock on the natural frequency of blood pressure transducer kits.

    Science.gov (United States)

    Fujiwara, Shigeki; Tachihara, Keiichi; Mori, Satoshi; Ouchi, Kentaro; Yokoe, Chizuko; Imaizumi, Uno; Morimoto, Yoshinari; Miki, Yoichiro; Toyoguchi, Izumi; Yoshida, Kazu-Ichi; Yokoyama, Takeshi

    2016-12-01

    Blood pressure transducer kits are equipped with two types of Planecta™ ports-the flat-type Planecta™ port (FTP) and the Planecta™ port with a three-way stopcock (PTS). We reported that FTP application decreased the natural frequency of the kits. However, Planecta™ is an invaluable tool as it prevents infection, ensures technical simplicity, and excludes air. Hence, an ideal Planecta™ port that does not decrease the frequency characteristics is required. As a first step in this direction, we aimed to assess the influence of PTSs on the natural frequency of blood transducer kits. A DTXplus transducer kit (DT4812J; Argon Medical Devices, TX, USA) was used along with ≥1 PTSs (JMS, Hiroshima, Japan), and the frequency characteristics were assessed. The natural frequency and damping coefficient of each kit were obtained by using frequency characteristics analysis software, and these parameters were evaluated by plotting them on Gardner's chart. Regardless of whether one or two PTSs were inserted, the natural frequency of the kits only slightly decreased (from 42.5 to 41.1 Hz, when 2 PTSs were used). Thus, the frequency characteristics of the kits with PTSs were adequate for pressure monitoring. The insertion of ≥2 FTPs in pressure transducer kits should be avoided, as they markedly decrease the natural frequency and lead to underdamping. However, the effect of PTS insertion in pressure transducer kits on the frequency characteristics is minimal. Thus, we found that the use of PTS markedly improved the frequency characteristics as compared to the use of FTP.

  5. The monitoring and verification of nuclear weapons

    International Nuclear Information System (INIS)

    Garwin, Richard L.

    2014-01-01

    This paper partially reviews and updates the potential for monitoring and verification of nuclear weapons, including verification of their destruction. Cooperative monitoring with templates of the gamma-ray spectrum are an important tool, dependent on the use of information barriers

  6. DarcyTools, Version 2.1. Verification and validation

    International Nuclear Information System (INIS)

    Svensson, Urban

    2004-03-01

    DarcyTools is a computer code for simulation of flow and transport in porous and/or fractured media. The fractured media in mind is a fractured rock and the porous media the soil cover on the top of the rock; it is hence groundwater flows, which is the class of flows in mind. A number of novel methods and features form the present version of DarcyTools. In the verification studies, these methods are evaluated by comparisons with analytical solutions for idealized situations. The five verification groups, thus reflect the main areas of recent developments. The present report will focus on the Verification and Validation of DarcyTools. Two accompanying reports cover other aspects: - Concepts, Methods, Equations and Demo Simulations. - User's Guide. The objective of this report is to compile all verification and validation studies that have been carried out so far. After some brief introductory sections, all cases will be reported in Appendix A (verification cases) and Appendix B (validation cases)

  7. Verification and quality control of routine hematology analyzers.

    Science.gov (United States)

    Vis, J Y; Huisman, A

    2016-05-01

    Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and linearity throughout the expected range of results. Yet, which standard should be met or which verification limit be used is at the discretion of the laboratory specialist. This paper offers practical guidance on verification and quality control of automated hematology analyzers and provides an expert opinion on the performance standard that should be met by the contemporary generation of hematology analyzers. Therefore (i) the state-of-the-art performance of hematology analyzers for complete blood count parameters is summarized, (ii) considerations, challenges, and pitfalls concerning the development of a verification plan are discussed, (iii) guidance is given regarding the establishment of reference intervals, and (iv) different methods on quality control of hematology analyzers are reviewed. © 2016 John Wiley & Sons Ltd.

  8. DarcyTools, Version 2.1. Verification and validation

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Urban [Computer-aided Fluid Engineering AB, Norrkoeping (Sweden)

    2004-03-01

    DarcyTools is a computer code for simulation of flow and transport in porous and/or fractured media. The fractured media in mind is a fractured rock and the porous media the soil cover on the top of the rock; it is hence groundwater flows, which is the class of flows in mind. A number of novel methods and features form the present version of DarcyTools. In the verification studies, these methods are evaluated by comparisons with analytical solutions for idealized situations. The five verification groups, thus reflect the main areas of recent developments. The present report will focus on the Verification and Validation of DarcyTools. Two accompanying reports cover other aspects: - Concepts, Methods, Equations and Demo Simulations. - User's Guide. The objective of this report is to compile all verification and validation studies that have been carried out so far. After some brief introductory sections, all cases will be reported in Appendix A (verification cases) and Appendix B (validation cases)

  9. Expression of c-kit receptor in human cholangiocarcinoma and in vivo treatment with imatinib mesilate in chimeric mice

    Science.gov (United States)

    Kamenz, Thomas; Caca, Karel; Blüthner, Thilo; Tannapfel, Andrea; Mössner, Joachim; Wiedmann, Marcus

    2006-01-01

    AIM: To investigate the c-kit expression in biliary tract cancer cell lines and histological sections from patients with extrahepatic cholangiocarcinoma (CC) and to evaluate the efficacy of in vitro and in vitro treatment with imatinib mesilate. METHODS: The protein expression of c-kit in the human biliary tract cancer cell lines Mz-ChA-2 and EGI-1 and histological sections from 19 patients with extrahepatic CC was assessed by immunoblotting, immunocytochemistry, and immunohistochemistry. The anti-proliferative effect of imatinib mesilate on biliary tract cancer cell lines Mz-ChA-2 and EGI-1 was studied in vitro by automated cell counting. In addition, immunodeficient NMRI mice (TaconicTM) were subcutaneously injected with 5 x 106 cells of cell lines MzChA-2 and EGI-1. After having reached a tumour volume of 200 mm3, daily treatment was started intraperitoneally with imatinib mesilate at a dose of 50 mg/kg or normal saline (NS). Tumor volume was calculated with a Vernier caliper. After 14 d, mice were sacrificed with tumors excised and tumor mass determined. RESULTS: Immunoblotting revealed presence of c-kit in Mz-ChA-2 and absence in EGI-1 cells. Immunocytochemistry with c-kit antibodies displayed a cytoplasmatic and membraneous localization of receptor protein in Mz-ChA-2 cells and absence of c-kit in EGI-1 cells. c-kit was expressed in 7 of 19 (37%) extrahepatic human CC tissue samples, 2 showed a moderate and 5 a rather weak immunostaining. Imatinib mesilate at a low concentration of 5 µmol/L caused a significant growth inhibition in the c-kit positive cell line Mz-ChA-2 (31%), but not in the c-kit negative cell line EGI-1 (0%) (P < 0.05). Imatinib mesilate at an intermediate concentration of 10 µmol/L inhibited cellular growth of both cell lines (51% vs 57%). Imatinib mesilate at a higher concentration of 20 µmol/L seemed to have a general toxic effect on both cell lines. The IC50 values were 9.7 µmol/L and 11 µmol/L, respectively. After 14 d of in vitro

  10. Travel Policies in ARL Libraries. SPEC Kit 161.

    Science.gov (United States)

    Cramer, Michael D.

    This kit examines the methods and policies currently used to provide travel funding for academic librarians. The results of a survey of Association of Research Libraries (ARL) libraries (n=73) conducted in Fall 1989 are presented as well as examples of travel policies and guidelines submitted by the following respondents: the Universities of…

  11. Verification-Based Interval-Passing Algorithm for Compressed Sensing

    OpenAIRE

    Wu, Xiaofu; Yang, Zhen

    2013-01-01

    We propose a verification-based Interval-Passing (IP) algorithm for iteratively reconstruction of nonnegative sparse signals using parity check matrices of low-density parity check (LDPC) codes as measurement matrices. The proposed algorithm can be considered as an improved IP algorithm by further incorporation of the mechanism of verification algorithm. It is proved that the proposed algorithm performs always better than either the IP algorithm or the verification algorithm. Simulation resul...

  12. Multi-canister overpack project - verification and validation, MCNP 4A

    International Nuclear Information System (INIS)

    Goldmann, L.H.

    1997-01-01

    This supporting document contains the software verification and validation (V and V) package used for Phase 2 design of the Spent Nuclear Fuel Multi-Canister Overpack. V and V packages for both ANSYS and MCNP are included. Description of Verification Run(s): This software requires that it be compiled specifically for the machine it is to be used on. Therefore to facilitate ease in the verification process the software automatically runs 25 sample problems to ensure proper installation and compilation. Once the runs are completed the software checks for verification by performing a file comparison on the new output file and the old output file. Any differences between any of the files will cause a verification error. Due to the manner in which the verification is completed a verification error does not necessarily indicate a problem. This indicates that a closer look at the output files is needed to determine the cause of the error

  13. Metabolic and growth response of mink (Neovison vison) kits until 10 weeks of age when exposed to different dietary protein provision

    DEFF Research Database (Denmark)

    Larsson, Caroline; Fink, Rikke; Matthiesen, Connie Marianne Frank

    2012-01-01

    to solid feed. The capacity to regulate the rate of gluconeogenesis was even more limited in young mink kits than in adult dams. However, young mink kits can regulate protein oxidation in response to dietary protein supply, probably by adapting the size of the liver and kidneys to the level of protein......Growth performance and metabolism were investigated in mink kits (n = 210) exposed to the same dietary treatment as their dams (n = 30), i.e. high (HP; 61% of metabolisable energy, ME), medium (MP; 48% of ME) or low (LP; 30% of ME) protein supply, from birth until 10 weeks of age. The kits were...... the heaviest. After transition to solid feed MP kits weighed most at nine weeks of age (p age, the kits fed the LP diet retained less (p

  14. 76 FR 72935 - Amended Authorization of Emergency Use of Doxycycline Hyclate Tablet Emergency Kits for Eligible...

    Science.gov (United States)

    2011-11-28

    ...] Amended Authorization of Emergency Use of Doxycycline Hyclate Tablet Emergency Kits for Eligible United... to the Emergency Use Authorization (EUA) (the Authorization) for doxycycline hyclate tablet emergency... Doxycyline Hyclate Tablet Emergency Kits, as Amended In 2004, the Secretary of the Department of Homeland...

  15. Development a nucleus kit of Mebrofenin-Sn+2 for the instant labelled with Tc-99m

    International Nuclear Information System (INIS)

    Salazar M, T.

    1996-01-01

    This work development a kit of Mebrofenin-Sn +2 packing in glass flask like white solid by freeze-drying, sterile and apyrogenicity. For it's use, the kit was reconstituted with a sodium pertechnetate solution ( 99m TcO 4 Na) to obtain a 99m Tc-Mebrofenin solution colorless, sterile, isotonic, apyrogenicity and no toxic; to be administrated intravenously and to be used for hepatobiliary diagnose. The goal was make an active source for the production of the kit; in this work was development and analysis for the active source by HPLC; it was optimized the procedure to obtain the radiopharmaceutical, it makes a stability study to give a logical date of caducity, and finally it makes a process validation to guarantee the reproducibility of the process development for the production of the 99m Tc-Mebrofenin kit; in the same way the quality specifications for the final product. (Author)

  16. Comparison of two commercial DNA extraction kits for the analysis of nasopharyngeal bacterial communities

    Directory of Open Access Journals (Sweden)

    Keith A. Crandall

    2016-04-01

    Full Text Available Characterization of microbial communities via next-generation sequencing (NGS requires an extraction ofmicrobial DNA. Methodological differences in DNA extraction protocols may bias results and complicate inter-study comparisons. Here we compare the effect of two commonly used commercial kits (Norgen and Qiagenfor the extraction of total DNA on estimatingnasopharyngeal microbiome diversity. The nasopharynxis a reservoir for pathogens associated with respiratory illnesses and a key player in understandingairway microbial dynamics. Total DNA from nasal washes corresponding to 30 asthmatic children was extracted using theQiagenQIAamp DNA and NorgenRNA/DNA Purification kits and analyzed via IlluminaMiSeq16S rRNA V4 ampliconsequencing. The Norgen samples included more sequence reads and OTUs per sample than the Qiagen samples, but OTU counts per sample varied proportionallybetween groups (r = 0.732.Microbial profiles varied slightly between sample pairs, but alpha- and beta-diversity indices (PCoAand clustering showed highsimilarity between Norgen and Qiagenmicrobiomes. Moreover, no significant differences in community structure (PERMANOVA and adonis tests and taxa proportions (Kruskal-Wallis test were observed betweenkits. Finally, aProcrustes analysis also showed low dissimilarity (M2 = 0.173; P< 0.001 between the PCoAs of the two DNA extraction kits. Contrary to what has been observed in previous studies comparing DNA extraction methods, our 16S NGS analysis of nasopharyngeal washes did not reveal significant differences in community composition or structure between kits. Our findingssuggest congruence between column-based chromatography kits and supportthe comparison of microbiomeprofilesacross nasopharyngeal metataxonomic studies.

  17. Interoperability in the OpenDreamKit Project: The Math-in-the-Middle Approach

    OpenAIRE

    Dehaye, Paul-Olivier; Kohlhase, Michael; Konovalov, Alexander; Lelièvre, Samuel; Pfeiffer, Markus; Thiéry, Nicolas M.

    2016-01-01

    OpenDreamKit - "Open Digital Research Environment Toolkit for the Advancement of Mathematics" - is an H2020 EU Research Infrastructure project that aims at supporting, over the period 2015-2019, the ecosystem of open-source mathematical software systems. OpenDreamKit will deliver a flexible toolkit enabling research groups to set up Virtual Research Environments, customised to meet the varied needs of research projects in pure mathematics and applications. An important step in the OpenDreamKi...

  18. Key Nuclear Verification Priorities: Safeguards and Beyond

    International Nuclear Information System (INIS)

    Carlson, J.

    2010-01-01

    In addressing nuclear verification priorities, we should look beyond the current safeguards system. Non-proliferation, which the safeguards system underpins, is not an end in itself, but an essential condition for achieving and maintaining nuclear disarmament. Effective safeguards are essential for advancing disarmament, and safeguards issues, approaches and techniques are directly relevant to the development of future verification missions. The extent to which safeguards challenges are successfully addressed - or otherwise - will impact not only on confidence in the safeguards system, but on the effectiveness of, and confidence in, disarmament verification. To identify the key nuclear verification priorities, we need to consider the objectives of verification, and the challenges to achieving these. The strategic objective of IAEA safeguards might be expressed as: To support the global nuclear non-proliferation regime by: - Providing credible assurance that states are honouring their safeguards commitments - thereby removing a potential motivation to proliferate; and - Early detection of misuse of nuclear material and technology - thereby deterring proliferation by the risk of early detection, enabling timely intervention by the international community. Or to summarise - confidence-building, detection capability, and deterrence. These will also be essential objectives for future verification missions. The challenges to achieving these involve a mix of political, technical and institutional dimensions. Confidence is largely a political matter, reflecting the qualitative judgment of governments. Clearly assessments of detection capability and deterrence have a major impact on confidence. Detection capability is largely thought of as 'technical', but also involves issues of legal authority, as well as institutional issues. Deterrence has both political and institutional aspects - including judgments on risk of detection and risk of enforcement action being taken. The

  19. Key Nuclear Verification Priorities - Safeguards and Beyond

    International Nuclear Information System (INIS)

    Carlson, J.

    2010-01-01

    In addressing nuclear verification priorities, we should look beyond the current safeguards system. Non-proliferation, which the safeguards system underpins, is not an end in itself, but an essential condition for achieving and maintaining nuclear disarmament. Effective safeguards are essential for advancing disarmament, and safeguards issues, approaches and techniques are directly relevant to the development of future verification missions. The extent to which safeguards challenges are successfully addressed - or otherwise - will impact not only on confidence in the safeguards system, but on the effectiveness of, and confidence in, disarmament verification. To identify the key nuclear verification priorities, we need to consider the objectives of verification, and the challenges to achieving these. The strategic objective of IAEA safeguards might be expressed as: To support the global nuclear non-proliferation regime by: - Providing credible assurance that states are honouring their safeguards commitments - thereby removing a potential motivation to proliferate; and - Early detection of misuse of nuclear material and technology - thereby deterring proliferation by the risk of early detection, enabling timely intervention by the international community. Or to summarise - confidence-building, detection capability, and deterrence. These will also be essential objectives for future verification missions. The challenges to achieving these involve a mix of political, technical and institutional dimensions. Confidence is largely a political matter, reflecting the qualitative judgment of governments. Clearly assessments of detection capability and deterrence have a major impact on confidence. Detection capability is largely thought of as 'technical', but also involves issues of legal authority, as well as institutional issues. Deterrence has both political and institutional aspects - including judgments on risk of detection and risk of enforcement action being taken. The

  20. Resveratrol Improved the Progression of Chronic Prostatitis via the Downregulation of c-kit/SCF by Activating Sirt1.

    Science.gov (United States)

    He, Yi; Zeng, Huizhi; Yu, Yang; Zhang, Jiashu; Zeng, Xiaona; Gong, Fengtao; Duan, Xingping; Liu, Qi; Yang, Bo

    2017-07-19

    The regulation mechanism of inflammation inducing prostate carcinogenesis remains largely unknown. Therefore, we investigated the role of the c-kit/SCF pathway, which has been associated with the control of prostate carcinogenesis, in chronic prostatitis (CP) rats and evaluated the anti-prostatitis effect of resveratrol. We performed hemolysin and eosin staining to evaluate the histopathological changes in prostates. Multiple approaches evaluated the expression levels of c-kit, stem cell factor (SCF), Sirt1, and carcinogenesis-associated proteins. The CP group exhibited severe diffuse chronic inflammation. Meanwhile, the prostate cells appeared atypia; the activity of c-kit/SCF was upregulated, and carcinogenesis-associated proteins are dysregulated significantly in CP rats. Resveratrol treatment significantly improved these factors by Sirt1 activation. In summary, CP could further cause prostate carcinogenesis, which may be associated with activated c-kit/SCF signaling. Resveratrol treatment could improve the progression of CP via the downregulation of c-kit/SCF by activating Sirt1.