WorldWideScience

Sample records for modern diagnostic imaging

  1. Role of teleradiology in modern diagnostic imaging

    International Nuclear Information System (INIS)

    Chrzan, R.; Urbanik, A.; Wyrobek -Renczynska, M.; Podsiadlo, L.

    2004-01-01

    Teleradiology is a dynamically expanding technology of electronic transmission of radiologic images. History of teleradiology development, methods of obtaining images in digital form, media used for their transmission, factors affecting time of transmission, methods of visualization of transmitted images, attempts at standardization of new technology and at last typical applications of teleradiology were presented. Teleradiology from the position of technical curiosity advanced to the role of everyday work tool. Possibility of specialist diagnostic imaging assurance in poorly developed regions, not possessing sufficient number of radiologists, turned out particularly important. Cooperation of regional hospitals with specialist centers of diagnostic images reporting and archiving created a chance for making better use of owned equipment and reducing the costs of diagnostics. For the sake of broader and broader access to teleradiology not only over the world but also in Poland it is advisable to familiarize with its possibilities by both radiologists and clinicists using the results of diagnostic imaging. (author)

  2. Place of modern imaging methods and their influence on the diagnostic process

    International Nuclear Information System (INIS)

    Petkov, D.; Lazarova, I.

    1991-01-01

    The main trends in development of the modern imaging diagnostic methods are presented: increasing the specificity of CT, nuclear-magnetic resonance imaging, positron-emission tomography, digital substractional angiography, echography etc. based on modern technical improvements; objective representation of the physiological and biochemical divergencies in particular diseases; interventional radiology; integral application of different methods; improving the sensitivity and specificity of the methods based on developments in pharmacology (new contrast media, parmaceuticals influencing the function of examinated organs, etc.); the possibilities for data compilation and further computerized processing of primary data. Personal experience is reported with the exploitation of these methods in Bulgaria. Attention is also called to the unfavourable impact connected with the too strong technicization of the diagnostic and therapeutic process in a health, deontologic, economical and social respect. 15 refs

  3. Current role of the radiographers in imaging diagnostics, nuclear medicine and radiotherapy in modern departments

    International Nuclear Information System (INIS)

    Karidova, S.; Velkova, K.; Panamska, K.; Petkova, K.

    2006-01-01

    Full text: In the communication we set out to focus the attention of the medical staff and the public on the place and the constantly growing role (relative burden) of the radiographers in imaging diagnostics, nuclear medicine and radiotherapy in the field of modern medicine. The advanced radiographers level and rapid development of the contemporary equipment and apparatuses used in imaging diagnostics, nuclear medicine and radiotherapy, as well as the methods of their utilization, presuppose very good and constantly improving theoretical and practical training of the imaging technician. The radiographer fulfills responsible tasks under the guidance of the physician or independently and bears specific responsibilities. Having mastered the fundamentals of radiation protection, the imaging technician protects both himself and the patient from the impact of ionizing radiation. To be able to fulfill his/her constantly increasing duties and obligations, the imaging radiographer has acquired wide knowledge of general education subjects, subjects of general medicine and special subjects. The radiographer has a good knowledge of Latin and a modern foreign language, and he is also computer literate so as to be able to cope with the widely spread visualizing methods. The radiographer acquires additional post-graduate training to work in narrowly specialized fields as well as to improve his/her qualifications

  4. Evolution of modern nuclear medicine tumor-imaging diagnostics in clinical oncology

    International Nuclear Information System (INIS)

    Piperkova, E.

    2000-01-01

    The evolution of current nuclear medicine diagnostic is closely related to the technical progress in imaging equipment development, and application of radiopharmaceuticals (Rphs) with a different tumor-uptake mechanism. It is the aim of the study to present groups of tumor-imaging Rphs differing by tumor uptake mechanisms, used in clinical oncology. The obtained results are described, and compared with the ones reported by other researchers. Sensitivity and specificity of Rphs for cardio-scintigraphy with 99m Tc - MIBI and 201 Tl are relatively high, amounting to 93.7% and 60% respectively, in the various tumors. These indicators depend on the stage, location, histopathology, level of malignancy and biological activity of the neoplasm. 99m Tc - MIBI scintigraphy is endowed with considerable diagnostic potential for assaying multiple drug resistance (MDR), and is also a good criterion for its elimination following anti-MDR therapy. The obtained results show that radioimmunoscintigraphy (RIS) using different radiolabeled monoclonal antibodies (MoAb) have high sensitivity and specificity respectively: 86% and 80% in ovarian carcinoma with B72.3 antiTAG; 68.6% and 92.5% in colorectal carcinoma with B73.2 antiTAG, antiCEA, antiCA 19-9; 92% and 83% in breast cancer with antiCEA, 86.8% and 67-69% in malignant melanoma with 225.28s. Receptor scintigraphy may reach up to 86% sensitivity and 100% specificity in tumors saturated with somatostatin receptors. Positron emission tomography (PET) with 18F-FDG enhances the metabolic activity of tumor cells, and attains tumor-detecting rate amounting to 97%. Tumor imaging evolution characterized by the introduction and practical implementation of different Rphs, visualizing the functional and biochemical activity of tumor cells in the primary neoplasm, sentinel lymph nodes and distant metastases. radiolabelling of a variety of new biochemical substances, including DNA and RNA, drugs and lysosomes contributes to a successful imaging

  5. MODERN CAPABILITIES OF BREAST PATHOLOGY DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    I. V. Vysotskaya

    2015-01-01

    Full Text Available Every year more than 1 million new cases of breast cancer are being recorded worldwide. Choice of appropriate tactics of treatment depends on the timely diagnosis and correct assessment of the prevalence of cancer.The algorithm of patient»s examination includes clinical examination, X-ray mammography and ultrasonic diagnosis of breast. However, this is not sufficient for a complete interpretation of the patient»s condition in case of non-palpable breast formations, ambiguous interpretation of imaging under structural changes, increased density of breast tissue, etc.In this regard, the introduction of new technologies and their evaluation in terms of practicality is a logical and developing method of early diagnosis of breast pathology.One of the methods that enables enhancing the information capability of ultrasonic diagnosis of breast is elastography. It allows for the differential diagnosis of benign and malignant changes not only in the breast tissue, but also in the areas of regional lymph drainage.Promising method of modern diagnostic breast care is digital mammography tomosynthesis. However, in spite of the first and very optimisticdata, this technique is still far from standard.Complex diagnostics of breast pathology, in addition to clinical data and imaging results, are based on information obtained from biopsies. At the present stage core-biopsy is considered as the best way of verification, where the resulting material is subjected to immunohistochemical studies.Thus, the spectrum of diagnostic capabilities is constantly expanding. Highly informative techniques included in the daily practice today enable clinicians to achieve optimal results in curing even greater number of patients.

  6. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  7. Modern cartilage imaging of the ankle; Moderne Knorpelbildgebung des Sprunggelenks

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph [University Hospital Heidelberg (Germany). Diagnostic and Interventional Radiology; Jungmann, Pia M. [Technical Univ. Munich (Germany). Radiology; Kuni, Benita [Ortho-Zentrum Karlsruhe (Germany). Orthopedics and Trauma Surgery

    2017-10-15

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  8. A revolution in diagnostic imaging.

    Science.gov (United States)

    Mamula, Paul W

    2003-03-01

    In November 1966, Sandy Koufax, the star left-handed pitcher of the Los Angeles Dodgers, retired after spending his final season coping with traumatic arthritis in his elbow, the compounded effects of a sliding injury to his pitching arm the previous season and 12 years of hard throwing.1 Had his career begun a few years later, he might have been able to benefit from the advances in diagnostic imaging and treatment that were introduced at that time. Modern arthroscopy and computed tomography (CT) did not become available until the mid 1970s,2 and the first elbow reconstruction was done by Frank Jobe, MD, about 10 years after Koufax retired.1 Arthroscopy was first used as a diagnostic tool, but it later became a surgical tool, affecting treatment of knees, then, later, shoulders. Since 1973, when The Physician and Sportsmedicine was launched, we have witnessed a revolution in diagnostic imaging and are continuing to see an evolution of modalities.

  9. Modern diagnostic capabilities for vasospastic angina diagnostics (intracoronary provocative testing

    Directory of Open Access Journals (Sweden)

    А. А. Обединский

    2017-04-01

    Full Text Available This review is devoted to a topical problem of modern cardiology – techniques of diagnosing vasospastic angina. The results of retrospective and prospective studies on the efficacy and safety of vasospastic angina diagnostics are reviewed. The literature on the prevalence, progression and treatment of this pathology is discussed.Received 13 January 2017. Accepted 6 February 2017.Financing: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.

  10. Diagnostic Imaging Workshop

    International Nuclear Information System (INIS)

    Sociedad Argentina de Fisica Medica

    2012-01-01

    The American Association of Physicist in Medicine (AAPM), the International Organization for Medical Physics (IOMP) and the Argentina Society of Medical Physics (SAFIM) was organized the Diagnostic Imaging Workshop 2012, in the city of Buenos Aires, Argentina. This workshop was an oriented training and scientific exchange between professionals and technicians who work in medical physics, especially in the areas of diagnostic imaging, nuclear medicine and radiotherapy, with special emphasis on the use of multimodal imaging for radiation treatment, planning as well of quality assurance associates.

  11. Diagnostic imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Gradzki, J.; Nowak, S.; Paprzycki, W.

    1993-01-01

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author)

  12. Modern cartilage imaging of the ankle

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph; Jungmann, Pia M.; Kuni, Benita

    2017-01-01

    Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and

  13. Encyclopedia of diagnostic imaging

    International Nuclear Information System (INIS)

    Baert, A.L.

    2008-01-01

    The simple A to Z format provides easy access to relevant information in the field of imaging. Extensive cross references between keywords and related articles enable efficient searches in a user-friendly manner. Fully searchable and hyperlinked electronic online edition. The aim of this comprehensive encyclopedia is to provide detailed information on diagnostic radiology contributing to the broad field of imaging. The wide range of entries are written by leading experts. They will provide basic and clinical scientists in academia, practice and industry with valuable information about the field of diagnostic imaging. Those in related fields, students, teachers, and interested laypeople will also benefit from the important and relevant information on the most recent developments. Please note that this publication is available as print only or online only or print + online set. Save 75% of the online list price when purchasing the bundle. For more information on the online version please type the publication title into the search box above, then click on the eReference version in the results list. (orig.)

  14. Moyamoya disease: Diagnostic imaging

    International Nuclear Information System (INIS)

    Tarasów, Eugeniusz; Kułakowska, Alina; Łukasiewicz, Adam; Kapica-Topczewska, Katarzyna; Korneluk-Sadzyńska, Alicja; Brzozowska, Joanna; Drozdowski, Wiesław

    2011-01-01

    Moyamoya disease is a progressive vasculopathy leading to stenosis of the main intracranial arteries. The incidence of moyamoya disease is high in Asian countries; in Europe and North America, the prevalence of the disease is considerably lower. Clinically, the disease may be of ischaemic, haemorrhagic and epileptic type. Cognitive dysfunction and behavioral disturbance are atypical symptoms of moyamoya disease. Characteristic angiographic features of the disease include stenosis or occlusion of the arteries of the circle of Willis, as well as the development of collateral vasculature. Currently, magnetic resonance angiography and CT angiography with multi-row systems are the main imaging methods of diagnostics of the entire range of vascular changes in moyamoya disease. The most common surgical treatment combines the direct arterial anastomosis between the superficial temporal artery and middle cerebral, and the indirect synangiosis involving placement of vascularised tissue in the brain cortex, in order to promote neoangiogenesis. Due to progressive changes, correct and early diagnosis is of basic significance in selecting patients for surgery, which is the only effective treatment of the disease. An appropriate qualification to surgery should be based on a comprehensive angiographic and imaging evaluation of brain structures. Despite the rare occurrence of moyamoya disease in European population, it should be considered as one of causes of ischaemic or haemorrhagic strokes, especially in young patients

  15. The Downside of Diagnostic Imaging

    Science.gov (United States)

    An article about radiation exposure during computed tomography and nuclear imaging procedures and the risk of cancer. Several studies released in 2009 have helped to quantify the risk and the growing use of these diagnostic imaging methods.

  16. Picosecond image-converter diagnostics

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1975-01-01

    A brief review is presented of the improvements in picosecond image-converter diagnostics carried out since the previous Congress in 1972. The account is given under the following headings: picosecond image converter cameras for visible and x-ray radiation diagnostics; Nd:glass and ruby mode-locked laser measurements; x-ray plasma emission diagnostics; computer treatment of pictures produced by picosecond cameras. (U.K.)

  17. Digital imaging in diagnostic radiology. Image quality - radiation exposure

    International Nuclear Information System (INIS)

    Schmidt, T.; Stieve, F.E.

    1996-01-01

    The publication contains the 37 lectures of the symposium on digital imaging in diagnostic radiology, held in November 1995 at Kloster Seeon, as well as contributions enhancing the information presented in the lectures. The publication reflects the state of the art in this subject field, discusses future trends and gives recommendations and information relating to current practice in radiology. In-depth information is given about R and D activities for the digitalisation of X-ray pictures and the image quality required to meet the purposes of modern diagnostics. Further aspects encompass radiological protection and dose optimization as well as optimization of examination methods. (vhe) [de

  18. Phenomenology of Schizophrenia and the Representativeness of Modern Diagnostic Criteria.

    Science.gov (United States)

    Kendler, Kenneth S

    2016-10-01

    This article aims to determine the degree to which modern operationalized diagnostic criteria for schizophrenia reflect the main clinical features of the disorder as described historically by diagnostic experts. Amazon.com, the National Library of Medicine, and Forgottenbooks.com were searched for articles written or translated into English from 1900 to 1960. Clinical descriptions of schizophrenia or dementia praecox appearing in 16 textbooks or review articles published between 1899 and 1956 were reviewed and compared with the criteria for schizophrenia from 6 modern US operationalized diagnostic systems. Twenty prominent symptoms and signs were reported by 5 or more authors. A strong association was seen between the frequency with which the symptoms/signs were reported and the likelihood of their presence in modern diagnostic systems. Of these 20 symptoms/signs, 3 (thought disorder, delusions, and hallucinations) were included in all diagnostic systems and were among the 4 most frequently reported. Three symptoms/signs were added then kept in subsequent criteria: emotional blunting, changes in volition, and changes in social life. Three symptoms/signs were added but then dropped: bizarre delusions, passivity symptoms, and mood incongruity. Eleven symptoms/signs were never included in any diagnostic system. Compared with historical authors, modern criteria favored symptoms over signs. Odd movements and postures, noted by 16 of 18 historical authors, were absent from all modern criteria. DSM-5 criteria contain 6 of the 20 historically noted symptoms/signs. Although modern operationalized criteria for schizophrenia reflect symptoms and signs commonly reported by historical experts, many clinical features emphasized by these experts are absent from modern criteria. This is not necessarily problematic as diagnostic criteria are meant to index rather than thoroughly describe syndromes. However, the lack of correspondence in schizophrenia between historically important

  19. Imaging systems for medical diagnostics

    International Nuclear Information System (INIS)

    Krestel, E.

    1990-01-01

    This book provides physicians and clinical physicists with detailed information on today's imaging modalities and assists them in selecting the optimal system for each clinical application. Physicists, engineers and computer specialists engaged in research and development and sales departments will also find this book to be of considerable use. It may also be employed at universities, training centers and in technical seminars. The physiological and physical fundamentals are explained in part 1. The technical solutions contained in part 2 illustrate the numerous possibilities available in X-ray diagnostics, computed tomography, nuclear medical diagnostics, magnetic resonance imaging, sonography and biomagnetic diagnostics. (orig.)

  20. Modern Imaging Technology: Recent Advances

    International Nuclear Information System (INIS)

    Welch, Michael J.; Eckelman, William C.

    2004-01-01

    This 2-day conference is designed to bring scientist working in nuclear medicine, as well as nuclear medicine practitioners together to discuss the advances in four selected areas of imaging: Biochemical Parameters using Small Animal Imaging, Developments in Small Animal PET Imaging, Cell Labeling, and Imaging Angiogenesis Using Multiple Modality. The presentations will be on molecular imaging applications at the forefront of research, up to date on the status of molecular imaging in nuclear medicine as well as in related imaging areas. Experts will discuss the basic science of imaging techniques, and scheduled participants will engage in an exciting program that emphasizes the current status of molecular imaging as well as the role of DOE funded research in this area

  1. Diagnostic imaging in pregraduate integrated curricula

    International Nuclear Information System (INIS)

    Kainberger, F.; Kletter, K.

    2007-01-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

  2. [Diagnostic imaging in pregraduate integrated curricula].

    Science.gov (United States)

    Kainberger, F; Kletter, K

    2007-11-01

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula.

  3. Consultation in diagnostic imaging

    International Nuclear Information System (INIS)

    Scott, W.W. Jr.; Scott, P.P.

    1985-01-01

    This book's organization follows traditional lines; abdomen, chest, bone, OB/GYN, neuroradiology, interventional radiology. It provides the rationale for selecting or avoiding a particular imaging study. The inclusion of decision trees in this book is especially helpful in radiology where careful planning can prevent unnecessary radiation exposure, invasive measures, and extraordinary costs

  4. Fair in the face: modern diagnostics of midfacial trauma

    International Nuclear Information System (INIS)

    Zajaczek, J.E.W.; Rodt, T.; Keberle, M.

    2007-01-01

    Modern diagnostics of midfacial trauma are embedded in a diagnostic concept that is oriented to the therapeutic relevance for the individual. Critical analysis of the indicated and efficient radiological method in the acute phase shows that MSCT is currently the method of choice in the diagnosis of midfacial trauma. Besides extensive acquisition of data in the shortest time the possibilities of modern post-processing provide a three-dimensional picture of the often complex injuries in real time. Other perilous injuries are often more important especially for the polytrauma patient. With modern scan protocols intracranial injuries as well as injuries of bone and soft tissue of the head and neck region can be diagnosed during a single examination. Radiology plays a key role for the economically oriented strategy of patient care. (orig.)

  5. Diagnostic imaging of lymphomas in pediatric patients

    International Nuclear Information System (INIS)

    Petrova, A.

    2010-01-01

    Lymphoma is the third most common malignancy in children, after leukemias and brain tumors, most commonly during early childhood before 14 years. In definite stages cancer can engage all organs and systems. These conditions associate with immunodeficiency, increased susceptibility to infections and second neoplasms. The social importance of the problem requires early diagnosis, accurate staging, and assessment of the treatment and determination of the risk for relapse of the disease. The aim of the present review is to represent the role of the modern methods of diagnostic imaging - ultrasonography (US), Computed Tomography (CT), Magnetic Resonance Imaging (MRI) and Positron Emisson Tomography (PET) scan in the process of diagnostics, in the decision of therapeutic strategy and the follow-up of children with lymphomas

  6. Diagnostic imaging in ophthalmology

    International Nuclear Information System (INIS)

    Gonzalez, C.F.; Becker, M.H.; Flanagan, J.C.

    1986-01-01

    There are three sections in the book. The first section is a discussion of imaging techniques, which includes plain film radiography and multidirectional tomography of the orbit, computed tomography (CT) of the orbit and its use in the evaluation of ocular motility disorders, ultrasonography of the eye and orbit, investigation of the orbit by contrast techniques (which includes a brief review of angiography), the lachrimal drainage system, foreign body localization, and magnetic resonance imaging of the eye and orbit. There is extensive discussion of CT throughout the book. The second section is devoted to the role of these imaging methods in the evaluation of ophthalmic disorders. A discussion of congenital anomalies is useful for those centers that are exposed to unusual congenital anomalies and syndromes. Also included is evaluation of exophthalmous and thyroid ophthamalopathy, orbital tumors, lesions involving the visual pathways, CT assessment of paraorbital pathology (including basal and squamous cell tumors of the face), infection of the orbit, and orbital trauma. The third section is an overview of radiation therapy and malignant intraoccular tumors

  7. Workload measurement: diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nuss, Wayne [The Prince Charles Hospital, Chermside, QLD (Australia). Dept. of Medical Imaging

    1993-06-01

    Departments of medical imaging, as with many other service departments in the health industry, are being asked to develop performance indicators. No longer are they assured that annual budget allocations will be forthcoming without justification or some output measurement indicators that will substantiate a claim for a reasonable share of resources. The human resource is the most valuable and the most expensive to any department. This paper provides a brief overview of the research and implementation of a radiographer workload measurement system that was commenced in the Brisbane North Health Region. 2 refs., 10 tabs.

  8. Diagnostic imaging in COPD

    International Nuclear Information System (INIS)

    Owsijewitsch, Michael; Ley-Zaporozhan, Julia; Eichinger, Monika

    2011-01-01

    COPD is a heterogeneous disease defined by expiratory airflow limitation. Airflow limitation is caused by a variable combination of emphysematous destruction of lung parenchyma and small airway obstruction. Only advanced emphysema can be diagnosed by chest X-ray. Less severe emphysema and changes in small airways are commonly diagnosed by computed tomography. Typical visual appearance of pathologic changes in lung parenchyma and airways of COPD patients are presented, furthermore methods for quantitative assessment of these changes and the crucial role of imaging for surgical and bronchoscopic treatment in COPD are discussed. (orig.)

  9. Diagnostic imaging of exotic pets

    International Nuclear Information System (INIS)

    Silverman, S.

    1993-01-01

    Radiographic, ultrasonographic, and computed tomographic (CT) imaging are important diagnostic modalities in exotic pets. The use of appropriate radiographic equipment, film-screen combinations, and radiographic projections enhances the information obtained from radiographs. Both normal findings and common radiographic abnormalities are discussed. The use of ultrasonography and CT scanning for exotic small mammals and reptiles is described

  10. Diagnostic imaging of shoulder impingement

    International Nuclear Information System (INIS)

    Merl, T.; Weinhardt, H.; Oettl, G.; Lenz, M.; Riel, K.A.

    1996-01-01

    Magnetic resonance imaging is a method that has been advancing in the last few years to the modality of choice for diagnostic evaluation of the bone joints, as the method is capable of imaging not only the ossous but also the soft tissue components of the joint. MRI likewise has become an accepted method for diagnostic evaluation of syndromes of the shoulder, with high diagnostic accuracy in detecting rotator cuff lesions, or as an efficient MRI arthrography for evaluation of the instability or lesions of the labrocapsular complex. In the evaluation of early stages of shoulder impingement, the conventional MRI technique as a static technique yields indirect signs which in many cases do not provide the diagnostic certainty required in order to do justice to the functional nature of the syndrome. In these cases, functional MRI for imaging of the arm in abducted position and in rotational movement may offer a chance to early detect impingement and thus identify patients who will profit from treatment at an early stage [de

  11. Modern status and tendencies of the development of radionuclide diagnostics

    International Nuclear Information System (INIS)

    Abdurahmanov, J.A.

    2004-01-01

    Full text: Modern development of nuclear medicine is characterized by working out of unique new pharmaceuticals first of all, which allow to estimate a condition of different organs and tissues of the organism at cellular level. The most long-term is a creation of different peptide preparations and marking of different receptors, which allow to carry out researches of pathogenic diseases. Such preparations begin to take root not only for positron tomography, but also emissive tomography. One more very interesting direction is so-called directed transport of drugs, using specialized substances for delivery therapeutic and diagnostic dose immediate to necessary place. To use these radiopharmpreparations requires an equipment with according technique, in the first place with emissive and, especially, positron tomographs. In this plan, positron tomography is actively developing in the world, where exist about 30 denominations, already commercial, preparations for the researches in these fields as cardiology, oncology, and neurology. There are new emissive tomographs with two or three detectors under working out, which allow to carry out emissive tomography in a minimum time and with high solution. A weak point in the radio nuclear diagnostics is relatively not high spatial solution of apparatus. In the first place it concerns emissive tomographs and to least degree positron tomographs. Therefore the new tendency in the development of methods of diagnostics and apparatus is appearance of combined methods and apparatus, which connects emissive tomography with X-ray and NMR- tomography. Earliest apparatus of this class was working out for researching of animals and represented small combined with X-ray and NMR- tomograph. To day in the world appeared first such apparatus for patients - emissive tomograph combined with X-ray. These are works of the firms of CTI and Siemens. A first apparatus is in the Pittsburgh and gives good results. And second working out - is the

  12. Diagnostic imaging in internal medicine

    International Nuclear Information System (INIS)

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging

  13. Diagnostic imaging in focal epilepsy

    International Nuclear Information System (INIS)

    Zlatareva, D.

    2013-01-01

    Focal epilepsies account for 60% of all seizure disorders worldwide. In this review the classic and new classification system of epileptic seizures and syndromes as well as genetic forms are discussed. Magnetic resonance (MR) is the technique of choice for diagnostic imaging in focal epilepsy because of its sensitivity and high tissue contrast. The review is focused on the lack of consensus of imaging protocols and reported findings in refractory epilepsy. The most frequently encountered MRI findings in epilepsy are reported and their imaging characteristics are depicted. Diagnosis of hippocampal sclerosis and malformations of cortical development as two major causes of refractory focal epilepsy is described in details. Some promising new techniques as positron emission tomography computed tomography (PET/CT) and MR and PET/CT fusion are briefly discussed. Also the relevance of adequate imaging in focal epilepsy, some practical points in imaging interpretation and differential diagnosis are highlighted. (author)

  14. Appropriate use of diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, P.E.S.; Cockshott, W.P.

    1984-11-16

    This article discusses ways in which more appropriate use can be made of roentgenography with a resulting decrease in radiation doses to the patient population. The authors recommend that fewer films be made and that traditional roentgenography be replaced with endoscopy, ultrasound, computerized tomography, or angiography where appropriate. They also recommend that medical schools and medical subspecialty groups study the World Health Organization document which provides indications for diagnostic imaging, the choice of procedure and the limitations of each.

  15. Diagnostic imaging of the pancreas

    International Nuclear Information System (INIS)

    Araki, Tsutomu; Itai, Yuji

    1981-01-01

    Diagnostic imaging of the pancreas, ultrasonography (US), computed tomography (CT), radionuclide (RN) scintigraphy, angiography, and endoscopic retrograde pancreaticography (ERP). First three noninvasive methods, were the most effective to diagnose psudo-cyst or cystoadenoma. Especially, CT gives the clear image of inflammation and shows pancreatic stones and calcification, with high sensitivity. As for pancreatic carcinomas there was no noninvasive methods to apply at an early stage. In order to diagnose the cancer the combination of angiography and ERP was preferable. The problem was how to select the candidates for the investigation of combined method out of the patients with negative CT or US. (Tsunoda, M.)

  16. Diagnostic imaging of compression neuropathy

    International Nuclear Information System (INIS)

    Weishaupt, D.; Andreisek, G.

    2007-01-01

    Compression-induced neuropathy of peripheral nerves can cause severe pain of the foot and ankle. Early diagnosis is important to institute prompt treatment and to minimize potential injury. Although clinical examination combined with electrophysiological studies remain the cornerstone of the diagnostic work-up, in certain cases, imaging may provide key information with regard to the exact anatomic location of the lesion or aid in narrowing the differential diagnosis. In other patients with peripheral neuropathies of the foot and ankle, imaging may establish the etiology of the condition and provide information crucial for management and/or surgical planning. MR imaging and ultrasound provide direct visualization of the nerve and surrounding abnormalities. Bony abnormalities contributing to nerve compression are best assessed by radiographs and CT. Knowledge of the anatomy, the etiology, typical clinical findings, and imaging features of peripheral neuropathies affecting the peripheral nerves of the foot and ankle will allow for a more confident diagnosis. (orig.) [de

  17. Diagnostic imaging in child abuse

    International Nuclear Information System (INIS)

    Stoever, B.

    2007-01-01

    Diagnostic imaging in child abuse plays an important role and includes the depiction of skeletal injuries, soft tissue lesions, visceral injuries in ''battered child syndrome'' and brain injuries in ''shaken baby syndrome''. The use of appropriate imaging modalities allows specific fractures to be detected, skeletal lesions to be dated and the underlying mechanism of the lesion to be described. The imaging results must be taken into account when assessing the clinical history, clinical findings and differential diagnoses. Computed tomography (CT) and magnetic resonance imaging (MRI) examinations must be performed in order to detect lesions of the central nervous system (CNS) immediately. CT is necessary in the initial diagnosis to delineate oedema and haemorrhages. Early detection of brain injuries in children with severe neurological symptoms can prevent serious late sequelae. MRI is performed in follow-up investigations and is used to describe residual lesions, including parenchymal findings. (orig.) [de

  18. Diagnostic imaging of the hand

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Rainer [Hospital for Cardiovascular Diseases, Bad Neustadt an der Saale (Germany). Dept. of Radiology; Lanz, Ulrich [Perlach Hospital, Munich (Germany). Dept. of Hand Surgery

    2008-07-01

    With its complex anatomy and specialized biomechanics, the human hand has always presented physicians with a unique challenge when it comes to diagnosing and treating the diseases that afflict it. And while recent decades have seen a rapid increase in the number of therapeutic options, many diseases and injuries of the hand are still commonly misinterpreted. In diagnostic imaging of the hand, an interdisciplinary team, comprisingspecialists in radiology, surgery, and rheumatology, presents a comprehensive,reliable guide to this topographically intricate area. Highlights include: - More than 1000 high-quality illustrations - All state-of-the-art imaging modalities-including multidetector CT, with 2D displays and 3D reconstructions, and contrast-enhanced MRI with multi-channel, phased-array coils - An overview of all currently used methods of examination - A detailed presentation of the anatomic and functional foundations necessary for diagnosis - Full coverage of all disorders of the hand - Systematic treatment of each disease's definition, pathogenesis, and clinical symptoms, according to a graduated diagnostic plan - Easy-to-use format, featuring crisp images and line drawings seamlessly integrated with concise text, summary tables, and handy checklists - A heavily cross-referenced appendix of differential diagnosis tables - Emphasis on interdisciplinary consultation throughout designed to help both radiologists and clinicians develop the most efficient and effective strategies for evaluating and treating patients, Diagnostic imaging of the hand will leave specialists of all levels with a fresh appreciation for - and a richer understanding of - the expanding array of cutting-edge alternatives for diagnosing and treating disorders of the hand. (orig.)

  19. Diagnostic imaging of the hand

    International Nuclear Information System (INIS)

    Schmitt, Rainer; Lanz, Ulrich

    2008-01-01

    With its complex anatomy and specialized biomechanics, the human hand has always presented physicians with a unique challenge when it comes to diagnosing and treating the diseases that afflict it. And while recent decades have seen a rapid increase in the number of therapeutic options, many diseases and injuries of the hand are still commonly misinterpreted. In diagnostic imaging of the hand, an interdisciplinary team, comprisingspecialists in radiology, surgery, and rheumatology, presents a comprehensive,reliable guide to this topographically intricate area. Highlights include: - More than 1000 high-quality illustrations - All state-of-the-art imaging modalities-including multidetector CT, with 2D displays and 3D reconstructions, and contrast-enhanced MRI with multi-channel, phased-array coils - An overview of all currently used methods of examination - A detailed presentation of the anatomic and functional foundations necessary for diagnosis - Full coverage of all disorders of the hand - Systematic treatment of each disease's definition, pathogenesis, and clinical symptoms, according to a graduated diagnostic plan - Easy-to-use format, featuring crisp images and line drawings seamlessly integrated with concise text, summary tables, and handy checklists - A heavily cross-referenced appendix of differential diagnosis tables - Emphasis on interdisciplinary consultation throughout designed to help both radiologists and clinicians develop the most efficient and effective strategies for evaluating and treating patients, Diagnostic imaging of the hand will leave specialists of all levels with a fresh appreciation for - and a richer understanding of - the expanding array of cutting-edge alternatives for diagnosing and treating disorders of the hand. (orig.)

  20. Recent Advancements in Microwave Imaging Plasma Diagnostics

    International Nuclear Information System (INIS)

    Park, H.; Chang, C.C.; Deng, B.H.; Domier, C.W.; Donni, A.J.H.; Kawahata, K.; Liang, C.; Liang, X.P.; Lu, H.J.; Luhmann, N.C. Jr.; Mase, A.; Matsuura, H.; Mazzucato, E.; Miura, A.; Mizuno, K.; Munsat, T.; Nagayama, K.; Nagayama, Y.; Pol, M.J. van de; Wang, J.; Xia, Z.G.; Zhang, W-K.

    2002-01-01

    Significant advances in microwave and millimeter wave technology over the past decade have enabled the development of a new generation of imaging diagnostics for current and envisioned magnetic fusion devices. Prominent among these are revolutionary microwave electron cyclotron emission imaging (ECEI), microwave phase imaging interferometers, imaging microwave scattering and microwave imaging reflectometer (MIR) systems for imaging electron temperature and electron density fluctuations (both turbulent and coherent) and profiles (including transport barriers) on toroidal devices such as tokamaks, spherical tori, and stellarators. The diagnostic technology is reviewed, and typical diagnostic systems are analyzed. Representative experimental results obtained with these novel diagnostic systems are also presented

  1. Complications in diagnostic imaging. 2. ed.

    International Nuclear Information System (INIS)

    Ansell, G.; Wilkins, R.A.; Medical Research Council, Harrow

    1987-01-01

    Thirty-seven chapters review various complications which may arise for patients and staff in medical diagnostic imaging. Five of these chapters are indexed separately covering topics on the complications of using radiopharmaceuticals, safety considerations in magnetic resonance imaging, radiation hazards of diagnostic radiology and medico-legal problems involving diagnostic radiology in both the UK and the USA. (UK)

  2. Diagnostic imaging in fertility disorders

    International Nuclear Information System (INIS)

    Winfield, A.C.; Fleischer, A.C.

    1987-01-01

    Some 10%-15% of married couples are affected by a fertility disorder. The number of infertile couples seeking medical assistance has increased dramatically in the past decade. The roles of diagnostic imaging with radiography and US (conventional and transvaginal) is emphasized in the assessment of couples with fertility disorders and an unexpectedly higher incidence of fetal wastage secondary to unsuspected uterine anomalies. The most frequently utilized radiographic examination in infertile patients is hysterosalpingography (HSG). Techniques and complications of HSG are illustrated. The normal anatomy, variants, and congenital anomalies of the uterus and fallopian tubes are demonstrated, as are the numerous abnormalities such as filling defects of the uterine cavity, synechiae, effects of maternal diethylstilbestrol exposure, inflammatory tubal disease, and the more common HSG findings following uterine and tubal surgery. The role of diagnostic imaging in male infertility, including vasography and varicocele detection, are addressed. Conventional and transvaginal US in the management of gynecologic fertility disorders are examined, with an emphasis on follicular monitoring, guided follicular aspirations, endometrial evaluations, and evaluation of other disorders (such as endometriosis) associated with infertility

  3. Use of organoboranes in modern medical imaging

    International Nuclear Information System (INIS)

    Kabalka, G.W.

    1991-01-01

    Isotopically labeled materials have proven to be invaluable in chemical, medical, and biological research. Organoboranes are beginning to play a significant role in the synthesis of medically important materials which contain both stable and short-lived isotopes. The organic compounds of boron possess characteristics which make them ideal intermediates in radiopharmaceutical pathways; these include the facts that boron reactions tolerate a wide variety of physiologically active functionality and that the reactions proceed rapidly and in high yields. Boranes have found important applications in modern medical imaging techniques such as positron emission tomography (PET) and magnetic resonance imaging (MRI). (author)

  4. OPTIMIZATION OF DIAGNOSTIC IMAGING IN BREAST CANCER

    Directory of Open Access Journals (Sweden)

    S. A. Velichko

    2015-01-01

    Full Text Available The paper presents the results of breast imaging for 47200 women. Breast cancer was detected in 862 (1.9% patients, fibroadenoma in 1267 (2.7% patients and isolated breast cysts in 1162 (2.4% patients. Different types of fibrocystic breast disease (adenosis, diffuse fibrocystic changes, local fibrosis and others were observed in 60.1% of women. Problems of breast cancer visualization during mammography, characterized by the appearance of fibrocystic mastopathy (sclerosing adenosis, fibrous bands along the ducts have been analyzed. Data on the development of diagnostic algorithms including the modern techniques for ultrasound and interventional radiology aimed at detecting early breast cancer have been presented.  

  5. Modern imaging of myocarditis. Possibilities and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Baessler, B.; Maintz, D.; Bunck, A.C. [University Hospital of Cologne (Germany). Dept. of Radiology; Koeln Univ. (Germany). Radiology; Schmidt, M. [University Hospital of Cologne (Germany). Dept. of Nuclear Medicine; Luecke, C. [Universitaetsklinikum Leipzig, Herzzentrum Leipzig GmbH (Germany). Diagnostic and Interventional Radiology; Blazek, S. [Universitaetsklinikum Leipzig, Herzzentrum Leipzig GmbH (Germany). Dept. of Internal Medicine/Cardiology; Ou, P. [Universite Paris Diderot (France). Dept. of Cardiovascular Imaging

    2016-10-15

    Myocarditis is known as the chameleon of cardiac diseases. The symptoms and the course of disease vary greatly so that it is often challenging to establish a diagnosis. Early and accurate diagnosis is of utmost importance, since myocarditis is one of the leading causes of sudden cardiac death in young adults and represents an important precursor to dilated cardiomyopathy. Due to the constraints of the routinely used diagnostic approach, including clinical history and examination, laboratory testing, and electrocardiogram, different imaging modalities have emerged over the last decades as contributors to the noninvasive diagnosis of myocarditis. With this interdisciplinary review we would like to present the current state-of-the-art imaging of myocarditis across all available imaging modalities (i.e., echocardiography, cardiac magnetic resonance, cardiac computed tomography, and nuclear medicine). Furthermore, we present novel imaging techniques that might become useful in the near future for easier and more accurate diagnosis of this highly relevant disease.

  6. Modern imaging of liver metastases; Moderne Bildgebung der Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, J.; Pones, M.; Wengert, G.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Allgemeines Krankenhaus, Wien (Austria)

    2015-01-01

    The liver is the second most common location of metastases following the lymph nodes. The accurate characterization of focal liver lesions in oncology patients is especially important because of the high prevalence of benign liver lesions and the possibility of co-existing benign and malignant lesions. The exact interpretation of these lesions is crucial for therapeutic decisions and thus for the prognosis of the patient. It is essential to detect all focal liver lesions and to distinguish benign from malignant lesions, especially in the management of oncology patients. Numerous imaging modalities are available for these challenges in the daily routine. An extensive understanding of the advantages and limitations of the various imaging modalities and knowledge of the morphology and the typical and atypical appearances of the different metastases is important. This review explains the radiological criteria for various metastases in different modalities. To evaluate the individual prognosis and risk assessment preoperatively, functional imaging is necessary. These personalized pretherapeutic diagnostics are discussed. (orig.) [German] Die Leber stellt nach den Lymphknoten die zweithaeufigste Lokalisation von Metastasen dar. Aufgrund der hohen Praevalenz gutartiger Leberlaesionen ist die genaue Charakterisierung fokaler Leberlaesionen bei Patienten mit bekanntem Malignom besonders wichtig, da maligne und benigne Tumoren koexistieren koennen. Die eindeutige Zuordnung dieser Laesionen ist entscheidend fuer die Therapie und somit die Prognose des Patienten. Insbesondere fuer das Management onkologischer Patienten ist es daher essenziell, alle fokalen Leberlaesionen zu detektieren und zwischen benignen und malignen zu differenzieren. Um dieser Anforderung im radiologischen Alltag nachzukommen, stehen derzeit zahlreiche Bildgebungsmodalitaeten zur Verfuegung. Daher sind sowohl ein tiefgreifendes Verstaendnis der Vorteile und Limitationen der verschiedenen diagnostischen

  7. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  8. [Diagnostic imaging and radiation hazards].

    Science.gov (United States)

    Claudon, Michel; Guillaume, Luc

    2015-01-01

    For the last 20 years, the exposure of the population to medical radiation has been increased by 600%, mainly due to the extension of new imaging modalities such as CT or interventional radiology. The risk for radio-induced hazards is especially marked for children, because of the high sensivity of tissues to radiation especially during the first decade of the life. Two main ways allow to better control and reduce the mean effective dose per patient in diagnostic imaging: the introduction of recent technical improvement (i.e. low dose CT scans using iterative reconstruction algorithms, low dose technique for pediatric spine), and the substitution to non-radiating techniques such as ultrasound and MRI. The French National institute of Radioprotection and Nuclear Safety periodically publishes dose reference levels for conventional films and CT examinations, for both adults and pediatric patients. A close relationship between clinicians and radiologists remains essential for a better appreciation of the risk/benefit ratio of each individual examination using X-Rays.

  9. Modern diagnostic and treatment aspects of diabetic macular edema

    Directory of Open Access Journals (Sweden)

    Alexander Viktorovich Doga

    2014-10-01

    Full Text Available Diabetic macular oedema (DMO is the leading cause of vision loss and disability in working-age people with diabetes mellitus. This literature review describes pathogenetic mechanisms, concepts, diagnostic techniques and capabilities of novel laser technologies in the treatment of DMO. In recent years, the role of cytokines and growth factors in retinal neurodegeneration has been actively investigated. Modern diagnostic techniques for the treatment of diabetic macular oedema, in addition to conventional techniques, include optical coherence tomography, autofluorescence and microperimetry. These techniques allow the visualization of retinal structures and its functional condition, and they can be used to detect DMO at early stages and to provide the most effective treatment. The evolution of laser technology resulted in the formation of new approaches to DMO treatment. Subthreshold micropulse laser (SML treatment, in conjunction with conventional photocoagulation, has pronounced therapeutic effects. SML shows high selectivity towards retinal pigment epithelium while avoiding neurosensory retina injury. Owing to the chronic nature of DMO and pathogenetic mechanisms recently discovered, further elaboration of the SML technique appears to be a very promising treatment.

  10. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  11. Diagnostic Imaging in Snakes and Lizards

    OpenAIRE

    Banzato , Tommaso

    2013-01-01

    The increasing popularity of snakes and lizards as pets has led to an increasing demand of specialised veterinary duties in these animals. Diagnostic imaging is often a fundamental step of the clinical investigation. The interpretation of diagnostic images is complex and requires a broad knowledge of anatomy, physiology and pathology of the species object of the clinical investigation. Moreover, in order to achieve a correct diagnosis, the comparison between normal and abnormal diagnostic im...

  12. Diagnostic image workstations ofr PACS

    International Nuclear Information System (INIS)

    Meyer-Ebrecht, D.; Fasel, B.; Dahm, M.; Kaupp, A.; Schilling, R.

    1990-01-01

    Image workstations will be the 'window' to the complex infrastructure of PACS with its intertwined image modalities (image sources, image data bases and image processing devices) and data processing modalities (patient data bases, departmental and hospital information systems). They will serve for user-to-system dialogues, image display and local processing of data as well as images. Their hardware and software structures have to be optimized towards an efficient throughput and processing of image data. (author). 10 refs

  13. Modern magnetic resonance imaging of the liver; Modernes MR-Protokoll fuer die Leberbildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Hedderich, D.M.; Maintz, D.; Persigehl, T. [Universitaetsklinikum Koeln, Institut fuer Diagnostische und Interventionelle Radiologie, Koeln (Germany); Weiss, K. [Universitaetsklinikum Koeln, Institut fuer Diagnostische und Interventionelle Radiologie, Koeln (Germany); Philips Healthcare Deutschland, Hamburg (Germany)

    2015-12-15

    Magnetic resonance imaging (MRI) of the liver has become an essential tool in the radiological diagnostics of both focal and diffuse diseases of the liver and is subject to constant change due to technological progress. Recently, important improvements could be achieved by innovations regarding MR hardware, sequences and postprocessing methods. The diagnostic spectrum of MRI could be broadened particularly due to new examination sequences, while at the same time scanning time could be shortened and image quality has been improved. The aim of this article is to explain both the technological background and the clinical application of recent MR sequence developments and to present the scope of a modern MRI protocol for the liver. (orig.) [German] Die Magnetresonanztomographie (MRT) der Leber ist in der radiologischen Diagnostik fokaler und diffuser Lebererkrankungen fest etabliert und untersteht einem steten Wandel durch den fortwaehrenden technischen Fortschritt. Durch Neuerungen bei der Hardware, den Sequenzen und der Bildnachverarbeitung konnten in den letzten Jahren deutliche Fortschritte erzielt werden. Insbesondere auf dem Gebiet der Untersuchungssequenzen kam es zu Entwicklungen, die das diagnostische Spektrum der MRT erweiterten, zu einer Verkuerzung der Scanzeit fuehrten und zu einer Verbesserung der Bildqualitaet beitrugen. Gegenstand dieses Artikels ist es, den technischen Hintergrund und die klinische Anwendung neuerer Sequenztechniken zu erklaeren und so die Moeglichkeiten und den Umfang eines modernen MRT-Untersuchungsprotokolls fuer die Leber darzustellen. (orig.)

  14. Modern diagnostic procedures in disorders of the thyroid gland

    International Nuclear Information System (INIS)

    Grebe, S.F.; Mueller, H.

    1984-01-01

    For functional diagnostics the FT4 index is calculated from the T4 and T3U values. Hyperthyroidism is suggested or borderline values an found, the T3 test is carried out. An index of free iodine hormones (IFIH) can be calculated. (IFIH=T4+30 x T3(μg/100 ml)/ST3U). Hypothyroidism and borderline cases require TSH evaluation or even a TRH test. T4 and T3 autoantibodies can cause high or low values in spite of euthyroidism or hypothyroidism. Difference in FT4 values are found if the kits used were not made by the same manufacturer. These values help to determine hyperthyroidism in pregnancy. The FT3 value is better than the TT3 value in determining T3 hyperthyroidism in borderline cases. Autonomy can be guaranteed by the 123 I short test or the 20-min 99 m Tc uptake test before and after administration of T4. Location diagnostics by scintigraphy after administration of 99 m Tc or radioiodine determine localization, size, shape, and distribution of functioning thyroid tissue and metastases by iodine accumulation. This is imaging of biochemical processes. By ultrasonography, a physical method, cysts, disintegration cysts or parenchymal nodes can be recognized. X-ray films of the trachea can determine stenosis caused by a struma. In addition to the exact proof of an intrathoracal struma (front and back mediastine), a retrotracheal or retroesophageal thyroid gland can be seen in CT. RIA determination of the tumor markers calcitonin and TG support the diagnostics of medullar and follicular or papillary thyroid carcinoma. (orig.) [de

  15. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  16. Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology

    International Nuclear Information System (INIS)

    Doi, Kunio

    2006-01-01

    Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image transmission, most of which are included in a picture archiving and communication system (PACS). The content of this paper includes a short review of research and development in medical imaging science and technology, which covers (a) diagnostic imaging in the 1950s, (b) the importance of image quality and diagnostic performance, (c) MTF, Wiener spectrum, NEQ and DQE, (d) ROC analysis, (e) analogue imaging systems, (f) digital imaging systems, (g) image processing, (h) computer-aided diagnosis, (i) PACS, (j) 3D imaging and (k) future directions. Although some of the modalities are already very sophisticated, further improvements will be made in image quality for MRI, ultrasound and molecular imaging. The infrastructure of PACS is likely to be improved further in terms of its reliability, speed and capacity. However, CAD is currently still in its infancy, and is likely to be a subject of research for a long time. (review)

  17. Diagnostic and therapeutic capabilities of modern nuclear medicine

    International Nuclear Information System (INIS)

    Lee Myung-Chul, M.D

    2007-01-01

    Full text: Nuclear medicine activity began to expand in the latter half of 1970 in worldwide. In 1980, many countries experienced a rapid increase in the number of medical facilities with nuclear medicine modalities. Nuclear imagining procedures serve as effective diagnostic tools due to their unique ability to provide information that is function-specific and to gather detailed information from radiological exams and other treatment methods. In-vivo studies using SPECT and PET modalities have shown a trend of significant increase throughout the past two decades. Looking at the nuclear neurologic application, there is a rapid increase in last decade. Brain perfusion SPECT and brain PET were making it the most commonly and the most widely performed nuclear neuroimaging study. Since 1990s, conventional nuclear cardiology studies (MUGA and single pass study) declined in number. But myocardial SPECT only increased dramatically using thallium and Tc-99m-MIBI. MIBG imaging plays a prominent role in diagnosing pheochromocytomas/paragangliomas (including nonfunctional paragangliomas) and neuroblastomas. It may be regarded as a first-choice imaging technique, as it presents a wide range of clinical advantages in both the diagnosis and follow-up of these tumors. Regarding to the radioisotope treatment, only radioiodine therapy was used more clinically. But recently, some new treatment is being tried, for example Ho-166 and rhenium-188. I-131 MIBG therapy is an effective treatment for several neural crest tumors, with can be delivered safely, even in children, provided that the bone marrow is free of tumor cells. I-131 MIBG therapy is probably the best palliative treatment for patients with advanced disease, as the invasiveness and toxicity of this therapy compare favorably with that of chemotherapy, immunotherapy and external beam radiotherapy. In general, PET has been primarily used to evaluate ischemic heart disease and to perform diagnostic imaging of malignant tumor

  18. Does MR imaging effectively replace diagnostic arthroscopy

    International Nuclear Information System (INIS)

    Ruwe, P.; McCarthy, S.; Wright, J.; Randall, L.; Lynch, K.; Jokyl, P.

    1990-01-01

    This paper determines if MR imaging reduces the number of diagnostic arthroscopic procedures required in patients with knee complaints and if MR imaging is cost-effective compared with diagnostic arthroscopy. The cohort analysis consists of 100 patients seen in a sports medicine clinic by two orthopedic surgeons who agreed on well-defined criteria for performing MR imaging and arthroscopy. Each orthopedic surgeon referring a patient for MR imaging checked a form regarding the plans for arthroscopy. Outcome analysis was conducted at 6 months

  19. Ideologeme "Order" in Modern American Linguistic World Image

    Science.gov (United States)

    Ibatova, Aygul Z.; Vdovichenko, Larisa V.; Ilyashenko, Lubov K.

    2016-01-01

    The paper studies the topic of modern American linguistic world image. It is known that any language is the most important instrument of cognition of the world by a person but there is also no doubt that any language is the way of perception and conceptualization of this knowledge about the world. In modern linguistics linguistic world image is…

  20. Diagnostic imaging of child abuse

    Energy Technology Data Exchange (ETDEWEB)

    Oguma, Eiji; Aihara, Toshinori [Saitama Children' s Medical Center, Iwatsuki (Japan)

    2002-04-01

    The major role of imaging in cases of suspected child abuse is to identify the physical injuries and to confirm the occurrence of abuse. In severely abused infants, the imaging findings may be the only evidence for a diagnosis of inflicted injury. Imaging may be the first clue to abuse in children seen with apparent other conditions and lead to appropriate measures to protect them from the risk of more serious injury. The radiologist must be familiar with imaging findings of inflicted injuries to fulfill these roles. (author)

  1. Diagnostic imaging of child abuse

    International Nuclear Information System (INIS)

    Oguma, Eiji; Aihara, Toshinori

    2002-01-01

    The major role of imaging in cases of suspected child abuse is to identify the physical injuries and to confirm the occurrence of abuse. In severely abused infants, the imaging findings may be the only evidence for a diagnosis of inflicted injury. Imaging may be the first clue to abuse in children seen with apparent other conditions and lead to appropriate measures to protect them from the risk of more serious injury. The radiologist must be familiar with imaging findings of inflicted injuries to fulfill these roles. (author)

  2. Diagnostic imaging in intensive care patients

    International Nuclear Information System (INIS)

    Afione, Cristina; Binda, Maria del C.

    2004-01-01

    Purpose: To determine the role of imaging diagnostic methods in the location of infection causes of unknown origin in the critical care patient. Material and methods: A comprehensive medical literature search has been done. Recommendations for the diagnostic imaging of septic focus in intensive care patients are presented for each case, with analysis based on evidence. The degree of evidence utilized has been that of Oxford Center for Evidence-based Medicine. Results: Nosocomial infection is the most frequent complication in the intensive care unit (25 to 33%) with high sepsis incidence rate. In order to locate the infection focus, imaging methods play an important role, as a diagnostic tool and to guide therapeutic procedures. The most frequent causes of infection are: ventilation associated pneumonia, sinusitis, intra-abdominal infections and an acute acalculous cholecystitis. This paper analyses the diagnostic imaging of hospital infection, with the evaluation of choice methods for each one and proposes an algorithm to assess the septic patient. Conclusion: There are evidences, with different degrees of recommendation, for the use of diagnostic imaging methods for infectious focuses in critical care patients. The studies have been selected based on their diagnostic precision, on the capacity of the medical team and on the availability of resources, considering the risk-benefit balance for the best safety of the patient. (author)

  3. Child abuse. Diagnostic imaging of skeletal injuries

    International Nuclear Information System (INIS)

    Stenzel, Martin; Mentzel, Hans-Joachim

    2012-01-01

    Diagnostic imaging, besides medical history and clinical examination, is a major component in assessment of cases of suspected physical child abuse. Performance of proper imaging technique, and knowledge of specific injury patterns is required for accurate image interpretation by the radiologist, and serves protection of the child in case of proven abuse. On the other side, it is essential to protect the family in unjustified accusations. The reader will be familiarised with essentials of the topic 'Physical child abuse', in order to be able to correctly assess quality, completeness, and results of X-ray films. Moreover, opportunities and limitations of alternative diagnostic modalities will be discussed. (orig.)

  4. Radiogenomics: Creating a link between molecular diagnostics and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rutman, Aaron M. [Department of Radiology, University of California San Diego Medical Center, San Diego, CA 92103 (United States); Kuo, Michael D. [Department of Radiology, University of California San Diego Medical Center, San Diego, CA 92103 (United States); Center for Translational Medical Systems, University of California San Diego Medical Center, San Diego, CA 92103 (United States)], E-mail: mkuo@ucsd.edu

    2009-05-15

    Studies employing high-throughput biological techniques have recently contributed to an improved characterization of human cancers, allowing for novel sub-classification, better diagnostic accuracy, and more precise prognostication. However, requirement of surgical procurement of tissue among other things limits the clinical application of such methods in everyday patient care. Radiographic imaging is routine in clinical practice but is currently histopathology based. The use of routine radiographic imaging provides a potential platform for linking specific imaging traits with specific gene expression patterns that inform the underlying cellular pathophysiology; imaging features could then serve as molecular surrogates that contribute to the diagnosis, prognosis, and likely gene-expression-associated treatment response of various forms of human cancer. This review focuses on high-throughput methods such as microarray analysis of gene expression, their role in cancer research, and in particular, on novel methods of associating gene expression patterns with radiographic imaging phenotypes, known as 'radiogenomics.' These findings underline a potential future role of both diagnostic and interventional radiologists in genetic assessment of cancer patients with radiographic imaging studies.

  5. Radiogenomics: Creating a link between molecular diagnostics and diagnostic imaging

    International Nuclear Information System (INIS)

    Rutman, Aaron M.; Kuo, Michael D.

    2009-01-01

    Studies employing high-throughput biological techniques have recently contributed to an improved characterization of human cancers, allowing for novel sub-classification, better diagnostic accuracy, and more precise prognostication. However, requirement of surgical procurement of tissue among other things limits the clinical application of such methods in everyday patient care. Radiographic imaging is routine in clinical practice but is currently histopathology based. The use of routine radiographic imaging provides a potential platform for linking specific imaging traits with specific gene expression patterns that inform the underlying cellular pathophysiology; imaging features could then serve as molecular surrogates that contribute to the diagnosis, prognosis, and likely gene-expression-associated treatment response of various forms of human cancer. This review focuses on high-throughput methods such as microarray analysis of gene expression, their role in cancer research, and in particular, on novel methods of associating gene expression patterns with radiographic imaging phenotypes, known as 'radiogenomics.' These findings underline a potential future role of both diagnostic and interventional radiologists in genetic assessment of cancer patients with radiographic imaging studies.

  6. Managing digitally formatted diagnostic image data

    International Nuclear Information System (INIS)

    Templeton, A.W.; Dwyer, S.J.

    1985-01-01

    Diagnostic radiologists are very comfortable using analog radiographic film and interpreting its recorded images. To improve patient care, the radiologist has sought the finest quality radiographic film for use with the best radiographic imaging systems. The proper choice and use of x-ray tubes, generators, film-screen combinations, and contrast media has occupied the professional attention of the radiologist since the inception of radiology. Image quality can be significantly improved with digitally formatted diagnostic imaging systems by providing dynamic ranges in excess of those possible with analog x-ray films. In a CT scanner, the digital acquisition and reconstruction system can obtain a dynamic range (contrast resolution) of 10,000 to 1. Digital subtraction angiography systems achieve 10-bit dynamic ranges for each of the acquired television frames. Increases in the dynamic ranges of the various imaging modalities have been coupled with improved spatial resolution. A digitally formatted image is a two-dimensional, numerical array of discrete image elements. Each picture element is called a pixel. Each pixel has a discrete size. Figure 15.1 illustrates a digitally formatted image depicting the spatial resolution, array size, and quantization or numerical range of the pixel values. Currently, 512 x 512 image arrays are standard. Development of 1024 x 1024 digital arrays are underway. Significant improvements have also been achieved in the rates at which digital diagnostic imaging data can be acquired, manipulated, and archived

  7. Digital imaging in diagnostic radiology

    International Nuclear Information System (INIS)

    Newell, J.D. Jr.; Kelsey, C.A.

    1990-01-01

    This monograph on digital imaging provides a basic overview of this field at the present time. This paper covers clinical application, including subtraction angiography; chest radiology; genitourinary, gastrointestinal, and breast radiology; and teleradiology. The chest section also includes an explanation of multiple beam equalization radiography. The remaining chapters discuss some of the technical aspects of digital radiology. It includes the basic technology of digital radiography, image compression, and reconstruction information on the economics of digital radiography

  8. Modern diagnostics of cystic liver lesions and hemangiomas; Moderne Diagnostik zystischer Leberlaesionen und Haemangiome

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S.; Bastati-Huber, N.; Ba-Ssalamah, A. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Wien (Austria); Brancatelli, G. [Universitaetsklinikum Palermo, Abteilung Radiologie, Palermo (Italy)

    2015-01-01

    Cystic liver lesions incorporate a broad heterogeneous group of mostly benign but also malignant abnormalities. The radiological aim is the non-invasive diagnosis with the use of different imaging modalities to determine the type of lesion. The common generally asymptomatic incidental findings of cystic lesions on ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) must be classified on the basis of specific imaging features. Such a differentiation is essential because the clinical consequences and the appropriate therapy can vary depending on the underlying pathology. Due to the morphological overlap of many cystic lesions, conventional radiological methods are often insufficient. The huge advances in cross-sectional imaging (multidetector CT, MRI with special sequences and different contrast agents and MR cholangiopancreatography) in combination with the clinical history usually enable a non-invasive diagnosis. Pathognomonic morphological and hemodynamic lesion features, as well as a knowledge of the pathomechanisms, help to differentiate this broad spectrum of entities. In this article the different entities of cystic liver lesions, together with the appropriate diagnostic method for detection and distinction and including their strengths and limitations, are demonstrated. A well-founded knowledge about the development of various cystic liver lesions and the suitable choice of imaging method facilitate a non-invasive diagnosis. (orig.) [German] Die zystischen Leberlaesionen umfassen eine grosse heterogene Gruppe meist benigner, jedoch auch maligner Veraenderungen. Das radiologische Ziel ist die nichtinvasive Artdiagnose mithilfe verschiedener bildgebender Verfahren. Die haeufigen, meist asymptomatischen Zufallsbefunde in Ultraschall, CT und MRT muessen anhand spezieller bildgebender Kriterien klassifiziert werden. Eine Differenzierung ist hierbei essenziell, da die klinischen Konsequenzen und weiterfuehrenden Therapien je nach zugrunde

  9. The neutron imaging diagnostic at NIF (invited).

    Science.gov (United States)

    Merrill, F E; Bower, D; Buckles, R; Clark, D D; Danly, C R; Drury, O B; Dzenitis, J M; Fatherley, V E; Fittinghoff, D N; Gallegos, R; Grim, G P; Guler, N; Loomis, E N; Lutz, S; Malone, R M; Martinson, D D; Mares, D; Morley, D J; Morgan, G L; Oertel, J A; Tregillis, I L; Volegov, P L; Weiss, P B; Wilde, C H; Wilson, D C

    2012-10-01

    A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

  10. The neutron imaging diagnostic at NIF (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Merrill, F. E.; Clark, D. D.; Danly, C. R.; Drury, O. B.; Fatherley, V. E.; Gallegos, R.; Grim, G. P.; Guler, N.; Loomis, E. N.; Martinson, D. D.; Mares, D.; Morley, D. J.; Morgan, G. L.; Oertel, J. A.; Tregillis, I. L.; Volegov, P. L.; Wilde, C. H.; Wilson, D. C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Bower, D.; Dzenitis, J. M. [Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2012-10-15

    A neutron imaging diagnostic has recently been commissioned at the National Ignition Facility (NIF). This new system is an important diagnostic tool for inertial fusion studies at the NIF for measuring the size and shape of the burning DT plasma during the ignition stage of Inertial Confinement Fusion (ICF) implosions. The imaging technique utilizes a pinhole neutron aperture, placed between the neutron source and a neutron detector. The detection system measures the two dimensional distribution of neutrons passing through the pinhole. This diagnostic has been designed to collect two images at two times. The long flight path for this diagnostic, 28 m, results in a chromatic separation of the neutrons, allowing the independently timed images to measure the source distribution for two neutron energies. Typically the first image measures the distribution of the 14 MeV neutrons and the second image of the 6-12 MeV neutrons. The combination of these two images has provided data on the size and shape of the burning plasma within the compressed capsule, as well as a measure of the quantity and spatial distribution of the cold fuel surrounding this core.

  11. Diagnostic Medical Imaging in Pediatric Patients and Subsequent Cancer Risk.

    Science.gov (United States)

    Mulvihill, David J; Jhawar, Sachin; Kostis, John B; Goyal, Sharad

    2017-11-01

    The use of diagnostic medical imaging is becoming increasingly more commonplace in the pediatric setting. However, many medical imaging modalities expose pediatric patients to ionizing radiation, which has been shown to increase the risk of cancer development in later life. This review article provides a comprehensive overview of the available data regarding the risk of cancer development following exposure to ionizing radiation from diagnostic medical imaging. Attention is paid to modalities such as computed tomography scans and fluoroscopic procedures that can expose children to radiation doses orders of magnitude higher than standard diagnostic x-rays. Ongoing studies that seek to more precisely determine the relationship of diagnostic medical radiation in children and subsequent cancer development are discussed, as well as modern strategies to better quantify this risk. Finally, as cardiovascular imaging and intervention contribute substantially to medical radiation exposure, we discuss strategies to enhance radiation safety in these areas. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Fair in the face: modern diagnostics of midfacial trauma; Mitten ins Gesicht: Moderne bildgebende Diagnostik beim Gesichtsschaedeltrauma

    Energy Technology Data Exchange (ETDEWEB)

    Zajaczek, J.E.W. [Abt. Neuroradiologie (OE 8210), Zentrum Radiologie, Medizinische Hochschule Hannover (Germany); Abt. Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany); Rodt, T.; Keberle, M. [Abt. Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany)

    2007-07-15

    Modern diagnostics of midfacial trauma are embedded in a diagnostic concept that is oriented to the therapeutic relevance for the individual. Critical analysis of the indicated and efficient radiological method in the acute phase shows that MSCT is currently the method of choice in the diagnosis of midfacial trauma. Besides extensive acquisition of data in the shortest time the possibilities of modern post-processing provide a three-dimensional picture of the often complex injuries in real time. Other perilous injuries are often more important especially for the polytrauma patient. With modern scan protocols intracranial injuries as well as injuries of bone and soft tissue of the head and neck region can be diagnosed during a single examination. Radiology plays a key role for the economically oriented strategy of patient care. (orig.)

  13. A recommender system for medical imaging diagnostic.

    Science.gov (United States)

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  14. Diagnostic imaging in medicine. 2. ed.

    International Nuclear Information System (INIS)

    Reba, R.C.; Goodenough, D.J.

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume. (orig.)

  15. Diagnostic imaging in medicine. 2nd ed

    Energy Technology Data Exchange (ETDEWEB)

    Reba, R C; Goodenough, D J; Davidson, H F

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume.

  16. Diagnostic imaging of lipoma arborescens

    International Nuclear Information System (INIS)

    Martin, S.; Hernandez, L.; Romero, J.; Lafuente, J.; Poza, A.I.; Ruiz, P.; Jimeno, M.

    1998-01-01

    Objective. The imaging characteristics of lipoma arborescens using plain radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) are described. Design and patients. Five patients with a diagnosis of lipoma arborescens are presented. Three had monoarticular involvement of the knee joint. In the remaining two patients both knees and both hips, respectively, were affected. All patients were examined using plain radiographs and MRI. CT was employed in two cases. Results and conclusions. A conclusive diagnosis with exclusion of other synovial pathologies having similar clinical and radiological behaviour can be achieved on the basis of the MRI characteristics of lipoma arborescens. The aetiology of lipoma arborescens remains unknown, but its association with previous pathology of the affected joints in all our patients supports the theory of a non-neoplastic reactive process involving the synovial membrane. (orig.)

  17. Diagnostic imaging in neonatal stroke

    International Nuclear Information System (INIS)

    Kuhle, S.; Ipsiroglu, O.; Weninger, M.

    2000-01-01

    A cerebral artery infarction is an important differential diagnosis in the newborn with neurological abnormalities. Based on clinical data, its incidence is estimated to be 1 in 4000 newborns. Since the course is often subclinical, the true incidence is probably higher. Diagnosis: Cerebral ultrasound and Doppler sonography as readily available screening tools play a central role in the initial diagnosis of neonatal cerebral infarction. Definitive diagnosis is made by computed tomography or magnetic resonance imaging. Beside symptomatic anticonvulsive therapy, treatment aims at the prevention of secondary ischemic injury. Discussion: Three term infants with different clinical courses of neonatal stroke are presented to sensitize the clinician and the radiologist for this probably underdiagnosed entity. The role of imaging modalities in the diagnosis and follow-up of neonatal cerebral infarction is discussed. (orig.) [de

  18. Computer applications in diagnostic imaging.

    Science.gov (United States)

    Horii, S C

    1991-03-01

    This article has introduced the nature, generation, use, and future of digital imaging. As digital technology has transformed other aspects of our lives--has the reader tried to buy a conventional record album recently? almost all music store stock is now compact disks--it is sure to continue to transform medicine as well. Whether that transformation will be to our liking as physicians or a source of frustration and disappointment is dependent on understanding the issues involved.

  19. [Diagnostic imaging and acute abdominal pain].

    Science.gov (United States)

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  20. Integration of molecular imaging in treatment planning and delivery of modern radiotherapy

    International Nuclear Information System (INIS)

    Jacob, V.; Wilkens, J.J.

    2011-01-01

    Among various imaging modalities currently available, positron emission tomography (PET) has the potential to visualize processes on a molecular level. Molecular imaging, often also referred to as functional or biological imaging, brought a new dimension to diagnostics and therapy of cancer by providing images of metabolism and other processes in the human body and in tumours. PET was first applied for diagnostics and staging of various tumours with high diagnostic precision. Modern radiotherapy asks increasingly for individualized treatment strategies, taking molecular imaging into account. Technical developments over the last years, in particular methods to register various imaging modalities within software packages for treatment planning and target delineation, facilitated the use of PET imaging in radiotherapy. In order to exploit the full potential of modern high-precision radiotherapy, exact imaging procedures are necessary, for example for precise target volume definition. In the long run, concepts employing an inhomogeneous dose prescription based on biological imaging may become routine in clinical applications, leading to individualized, biologically adaptive therapy. (orig.)

  1. Diagnostic imaging of skeletal metastases

    International Nuclear Information System (INIS)

    Scutellari, P. N.; Addonisio, G.; Righi, R.; Giganti, M.

    2000-01-01

    Purpose of this article is to present an algorithm for detection and diagnosis of skeletal metastases, which may be applied differently in symptomatic and asymptomatic cancer patients. February to March 1999 it was randomly selected and retrospectively reviewed the clinical charts of 100 cancer patients (70 women and 30 men; mean age: 63 years, range: 55-87). All the patients had been staged according to TNM criteria and had undergone conventional radiography and bone scan; when findings were equivocal, CT and MRI had been performed too. The primary lesions responsible for bone metastases were sited in the: breast (51 cases), colon (30 cases: 17 men and 13 women), lung (7 cases: 6 men and 1 woman), stomach (4 cases: 2 men and 2 women), skin (4 cases: 3 men and 1 woman), kidney (2 men), pleura (1 woman), and finally liver (1 man). The most frequent radiographic pattern was the lytic type (52%), followed by osteosclerotic, mixed, lytic vs mixed and osteosclerotic vs lytic patterns. The patients were divided into two groups: group A patients were asymptomatic and group B patients had local symptoms and/or pain. Skeletal metastases are the most common malignant bone tumors: the spine and the pelvis are the most frequent sites of metastasis, because of the presence of high amounts of red (hematopoietic active) bone marrow. Pain is the main symptom, even though many bone metastases are asymptomatic. Pathological fractures are the most severe consequences. With the algorithm for detection and diagnosis of skeletal metastases two different diagnostic courses are available for asymptomatic and symptomatic patients. Bone scintigraphy remains the technique of choice in asymptomatic patients in whom skeletal metastases are suspected. However this technique, though very sensitive, is poorly specific, and thus a negative bone scan finding is double-checked with another physical examination: if the findings remain negative, the diagnostic workup is over. On the contrary, in

  2. Rationale diagnostic approach to biliary tract imaging

    International Nuclear Information System (INIS)

    Helmberger, H.; Huppertz, A.; Ruell, T.; Zillinger, C.; Ehrenberg, C.; Roesch, T.

    1998-01-01

    Since the introduction of MR cholangiography (MRC) diagnostic imaging of the biliary tract has been significantly improved. While percutaneous ultrasonography is still the primary examination, computed tomography (CT), conventional magnetic resonance imaging (MRI), as well as the direct imaging modalities of the biliary tract - iv cholangiography, endoscopic-retrograde-cholangiography (ERC), and percutaneous-transhepatic-cholangiography (PTC) are in use. This article discusses the clinical value of the different diagnostic techniques for the various biliary pathologies with special attention to recent developments in MRC techniques. An algorithm is presented offering a rational approach to biliary disorders. With further technical improvement shifts from ERC(P) to MRC(P) for biliary imaging could be envisioned, ERCP further concentrating on its role as a minimal invasive treatment option. (orig.) [de

  3. Diagnostic reference levels in medical imaging

    International Nuclear Information System (INIS)

    Rosenstein, M.

    2001-01-01

    The paper proposes additional advice to national or local authorities and the clinical community on the application of diagnostic reference levels as a practical tool to manage radiation doses to patients in diagnostic radiology and nuclear medicine. A survey was made of the various approaches that have been taken by authoritative bodies to establish diagnostic reference levels for medical imaging tasks. There are a variety of ways to implement the idea of diagnostic reference levels, depending on the medical imaging task of interest, the national or local state of practice and the national or local preferences for technical implementation. The existing International Commission on Radiological Protection (ICRP) guidance is reviewed, the survey information is summarized, a set of unifying principles is espoused and a statement of additional advice that has been proposed to ICRP Committee 3 is presented. The proposed advice would meet a need for a unifying set of principles to provide a framework for diagnostic reference levels but would allow flexibility in their selection and use. While some illustrative examples are given, the proposed advice does not specify the specific quantities to be used, the numerical values to be set for the quantities or the technical details of how national or local authorities should implement diagnostic reference levels. (author)

  4. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  5. Modern methods of early diagnostics of juvenile arthritis

    Directory of Open Access Journals (Sweden)

    Chernenkov Y.V.

    2013-06-01

    Full Text Available The problem of inflammatory diseases of joints is one of the most important issues in the pediatrics. Nowadays the significant attention in this sphere is paid to the search of new accurate criteria of diagnostics. It will help estimate the severity of disease, determine the prognosis, choose the method of treatment and monitoring and evaluate the efficacy of the therapy.

  6. Meniscal tear. Diagnostic errors in MR imaging

    International Nuclear Information System (INIS)

    Barrera, M. C.; Recondo, J. A.; Gervas, C.; Fernandez, E.; Villanua, J. A.M.; Salvador, E.

    2003-01-01

    To analyze diagnostic discrepancies found between magnetic resonance (MR) and arthroscopy, and the determine the reasons that they occur. Two-hundred and forty-eight MR knee explorations were retrospectively checked. Forty of these showed diagnostic discrepancies between MR and arthroscopy. Two radiologists independently re-analyzed the images from 29 of the 40 studies without knowing which diagnosis had resulted from which of the two techniques. Their interpretations were correlated with the initial MR diagnosis, MR images and arthroscopic results. Initial errors in MR imaging were classified as either unavoidable, interpretive, or secondary to equivocal findings. Eleven MR examinations could not be checked since their corresponding imaging results could not be located. Of 34 errors found in the original diagnoses, 12 (35.5%)were classified as unavoidable, 14 (41.2%) as interpretative and 8 (23.5%) as secondary to equivocal findings. 41.2% of the errors were avoided in the retrospective study probably due to our department having greater experience in interpreting MR images, 25.5% were unavailable even in the retrospective study. A small percentage of diagnostic errors were due to the presence of subtle equivocal findings. (Author) 15 refs

  7. Diagnostic value of sectional images obtained by emission tomography

    International Nuclear Information System (INIS)

    Roucayrol, J.C.

    1981-01-01

    It is now possible to obtain clear images of the various planes in and around a structure with ultra-sounds (echotomography), X-rays (computerized tomography) and recently, gamma-rays from radioactive substances (emission tomography). Axial transverse tomography, which is described here, is to conventional scintigraphy what CT scan is to radiography. It provides images of any structure capable of concentrating sufficiently a radioactive substance administered intravenously. These images are perpendicular to the longitudinal axis of the body. As shown by examples in the liver, lungs and myocardium, lesions which had passed unnoticed with other exploratory techniques can now be demonstrated, and the location, shape and extension of known lesions can be more accurately assessed. Emission tomography already has its place in modern diagnostic procedures side by side with echotomography and CT scan [fr

  8. Modern Technologies In Ectopic Pregnancy Diagnostics On Hospital Stage

    Directory of Open Access Journals (Sweden)

    L.V. Kaushanskaya

    2009-12-01

    Full Text Available The present research provides analysis of results of preoperative examination of 680 patients with ectopic pregnancy depending on the range of surgical treatment. It has been shown that in case of progressive ectopic pregnancy the diagnostic significance of concentrations of human chorionic gonadotropin, transvaginal examination and laparos-copy depends on the duration of pregnancy. When the term of ectopic pregnancy is 3-4 weeks monitoring of p chorionic gonadotropin in blood serum (99.5%, transvaginal examination (58% and laparoscopy (78.5% are more informative. When the term of ectopic pregnancy is more than 4 weeks there is a high diagnostic value of monitoring p-subunit of chorionic gonadotropin (99.5%, transvaginal examination (68% and laparoscopy (99,5%. The research has proved that pregnancy period of 3-4 weeks is optimal for laparoscopy and other operations

  9. A modern diagnostic approach for automobile systems condition monitoring

    Science.gov (United States)

    Selig, M.; Shi, Z.; Ball, A.; Schmidt, K.

    2012-05-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  10. A modern diagnostic approach for automobile systems condition monitoring

    International Nuclear Information System (INIS)

    Selig, M; Ball, A; Shi, Z; Schmidt, K

    2012-01-01

    An important topic in automotive research and development is the area of active and passive safety systems. In general, it is grouped in active safety systems to prevent accidents and passive systems to reduce the impact of a crash. An example for an active system is ABS while a seat belt tensioner represents the group of passive systems. Current developments in the automotive industry try to link active with passive system components to enable a complete event sequence, beginning with the warning of the driver about a critical situation till the automatic emergency call after an accident. The cross-linking has an impact on the current diagnostic approach, which is described in this paper. Therefore, this contribution introduces a new diagnostic approach for automotive mechatronic systems. The concept is based on monitoring the messages which are exchanged via the automotive communication systems, e.g. the CAN bus. According to the authors' assumption, the messages on the bus are changing between faultless and faulty vehicle condition. The transmitted messages of the sensors and control units are different depending on the condition of the car. First experiments are carried and in addition, the hardware design of a suitable diagnostic interface is presented. Finally, first results will be presented and discussed.

  11. Thymic hyperplasia - clinical course and imaging diagnostic

    International Nuclear Information System (INIS)

    Drebov, R.; Panov, M.; Totev, M.; Deliverski, T.; Tcandev, I.; Velkovski, I.

    2006-01-01

    The real thymic hyperplasia is benign disease sometimes simulating malignant tumours. The aim of this study is to analyse the clinical symptoms of real thymic hyperplasia and the results from imaging diagnostic based on our clinical material. Clinical material include 27 children, aged from two months to 15 years, admitted in department of thoracic surgery, for a period of 20 years (1985 - 2004). We retrospectively analyze the clinical signs and results from X-ray investigation, CT (Siemens Somatom DRG and Philips Secura) and echocardiography (Acuson TX, 5 and 7 MHz). We discuss the diagnostic value of different methods as well as typical and atypical findings. (authors)

  12. [Diagnostic imaging of breast cancer : An update].

    Science.gov (United States)

    Funke, M

    2016-10-01

    Advances in imaging of the female breast have substantially influenced the diagnosis and probably also the therapy and prognosis of breast cancer in the past few years. This article gives an overview of the most important imaging modalities in the diagnosis of breast cancer. Digital mammography is considered to be the gold standard for the early detection of breast cancer. Digital breast tomosynthesis can increase the diagnostic accuracy of mammography and is used for the assessment of equivocal or suspicious mammography findings. Other modalities, such as ultrasound and contrast-enhanced magnetic resonance imaging (MRI) play an important role in the diagnostics, staging and follow-up of breast cancer. Percutaneous needle biopsy is a rapid and minimally invasive method for the histological verification of breast cancer. New breast imaging modalities, such as contrast-enhanced spectral mammography, diffusion-weighted MRI and MR spectroscopy can possibly further improve breast cancer diagnostics; however, further studies are necessary to prove the advantages of these methods so that they cannot yet be recommended for routine clinical use.

  13. Diagnostic imaging of craniopharyngioma; Diagnostyka obrazowa czaszkogardlakow

    Energy Technology Data Exchange (ETDEWEB)

    Gradzki, J.; Nowak, S.; Paprzycki, W. [Akademia Medyczna, Poznan (Poland)

    1993-12-31

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author). 7 refs, 5 figs, 2 tabs.

  14. IRRITABLE BOWEL SYNDROME IN CHILDREN: DIAGNOSTICS AND MODERN APPROACHES TO THERAPY

    Directory of Open Access Journals (Sweden)

    S.Yu. Tereshchenko

    2006-01-01

    Full Text Available In the article modern data on prevalence, diagnostic criteria and approaches to the treatment of irritable bowel in children are presented. The issues of the terminology and classification of recurrent abdominal pains in children are clarified, the basic pathophysiological mechanisms of the disease are indicated. Particular emphasis has been placed on the efficient therapy of the different clinical variants of irritable bowel syndrome. The role of modern spasmolytic drugs in the treatment of abdominal pain syndrome and the rational usage of laxatives in constipation in children is shown.Key words: children, irritable bowel syndrome, diagnostics, treatment.

  15. [Cognitive functions, their development and modern diagnostic methods].

    Science.gov (United States)

    Klasik, Adam; Janas-Kozik, Małgorzata; Krupka-Matuszczyk, Irena; Augustyniak, Ewa

    2006-01-01

    provided a theory. The psychometric approach concentrates on studying the differences in intelligence. The aim of this approach is to test intelligence by means of standardized tests (e.g. WISC-R, WAIS-R) used to show the individual differences among humans. Human cognitive functions determine individuals' adaptation capabilities and disturbances in this area indicate a number of psychopathological changes and are a symptom enabling to differentiate or diagnose one with a disorder. That is why the psychological assessment of cognitive functions is an important part of patients' diagnosis. Contemporary neuropsychological studies are to a great extent based computer tests. The use of computer methods has a number of measurement-related advantages. It allows for standardized testing environment, increasing therefore its reliability and standardizes the patient assessment process. Special attention should be paid to the neuropsychological tests included in the Vienna Test System (Cognitron, SIGNAL, RT, VIGIL, DAUF), which are used to assess the operational memory span, learning processes, reaction time, attention selective function, attention continuity as well as attention interference resistance. It also seems justified to present the CPT id test (Continuous Performance Test) as well as Free Recall. CPT is a diagnostic tool used to assess the attention selective function, attention continuity of attention, attention interference resistance as well as attention alertness. The Free Recall test is used in the memory processes diagnostics to assess patients' operational memory as well as the information organization degree in operational memory. The above mentioned neuropsychological tests are tools used in clinical assessment of cognitive function disorders.

  16. Active imaging for monitoring and technical diagnostics

    Directory of Open Access Journals (Sweden)

    Marek Piszczek

    2014-08-01

    Full Text Available The article presents the results of currently running work in the field of active imaging. The term active refers to both the image acquisition methods, so-called methods of the spatio-temporal framing and active visualization method applying augmented reality. Also results of application of the HMD and 6DoF modules as well as the experimental laser photography device are given. The device works by methods of spatio-temporal framing and it has been developed at the IOE WAT. In terms of image acquisition - active imaging involves the use of illumination of the observed scene. In the field of information visualization - active imaging directly concerns the issues of interaction human-machine environment. The results show the possibility of using the described techniques, among others, rescue (fire brigade, security of mass events (police or the protection of critical infrastructure as well as broadly understood diagnostic problems. Examples presented in the article show a wide range of possible uses of the methods both in observational techniques and measurement. They are relatively innovative solutions and require elaboration of series of hardware and algorithmic issues. However, already at this stage it is clear that active acquisition and visualization methods indicate a high potential for this type of information solutions.[b]Keywords[/b]: active imaging, augmented reality, digital image processing

  17. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  18. Image enhancement of digital periapical radiographs according to diagnostic tasks

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung

    2014-01-01

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  19. Diagnostic imaging in pediatric renal inflammatory disease

    International Nuclear Information System (INIS)

    Sty, J.R.; Wells, R.G.; Schroeder, B.A.; Starshak, R.J.

    1986-01-01

    Some form of imaging procedure should be used to document the presence of infection of the upper urinary tract in troublesome cases in children. During the past several years, sonography, nuclear radiology, and computed tomography (CT) have had a significant influence on renal imaging. The purpose of this article is to reevaluate the noninvasive imaging procedures that can be used to diagnose pediatric renal inflammatory disease and to assess the relative value of each modality in the various types of renal infection. The authors will not discuss the radiologic evaluation of the child who has had a previous renal infection, in whom cortical scarring or reflux nephropathy is a possibility; these are different clinical problems and require different diagnostic evaluation

  20. Modern technical diagnostic system for the main components of powerful turbine generator

    International Nuclear Information System (INIS)

    Ezovit, G.P.; Uglyarenko, V.P.; Burlaka, S.I.; Goroz, N.I.; Orinin, S.E.; Komaritsa, V.N.; Zav'yalov, D.N.; Mazurenko, O.A.

    2011-01-01

    The modern diagnostic system to monitor the technical state of a powerful turbine generator is considered. This system permits the detection of defects in its main components and cooling system at the early stage of their development, prevention of damage and, as a consequence, emergency shutdown of nuclear power units

  1. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  2. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  3. Diagnostic imaging of the acutely injured patient

    International Nuclear Information System (INIS)

    Berquist, T.H.

    1985-01-01

    This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described

  4. Osteonecrosis of the sesamoid bone: contribution of modern imaging techniques

    International Nuclear Information System (INIS)

    Leleu, J.P.; Heno, P.; Rispal, P.; Joullie, M.; Laurent, F.

    1990-01-01

    We report a case of osteonecrosis of the sesamoid bone or Renander disease in a young male serviceman. Modern imaging techniques proved useful for identifying the lesion. CT scan and above all magnetic resonance imaging established the accurate diagnosis. The combination of a hypointense signal from the sesamoid bone with an effusion in the first metatarsophalangeal joint should be considered as characteristic of osteonecrosis of the sesamoid bone [fr

  5. Usefulness of diagnostic imaging in primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Sekiyama, Kazuya; Akakura, Koichiro; Mikami, Kazuo; Mizoguchi, Ken-ichi; Tobe, Toyofusa; Nakano, Koichi; Numata, Tsutomu; Konno, Akiyoshi; Ito, Haruo

    2003-01-01

    In patients with primary hyperparathyroidism, prevention of urinary stone recurrence can be achieved by surgical removal of the enlarged parathyroid gland. To ensure the efficacy of surgery for primary hyperparathyroidism, preoperative localization of the enlarged gland is important. In the present study, usefulness of diagnostic imaging for localization of the enlarged gland was investigated in primary hyperparathyroidism. We retrospectively examined the findings of imaging studies and clinical records in 79 patients (97 glands) who underwent surgical treatment for primary hyperparathyroidism at Chiba University Hospital between 1976 and 2000. The detection rates of accurate localization were investigated for imaging techniques, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) thallium-201 and technetium-99m pertechnetate (Tl-Tc) subtraction scintigraphy and 99m Tc-methoxyisobutylisonitrile (MIBI) scintigraphy, and analysed in relation to the size and weight of the gland and pathological diagnosis. The detection rates by US, CT, MRI, Tl-Tc subtraction scintigraphy and MIBI scintigraphy were 70%, 67%, 73%, 38% and 78%, respectively. The overall detection rate changed from 50% to 88% before and after 1987. The detection rate of MIBI scintigraphy was superior to Tl-Tc subtraction scintigraphy. In primary hyperparathyroidism, improvement of accurate localization of an enlarged parathyroid gland was demonstrated along with recent advances in imaging techniques including MIBI scintigraphy. (author)

  6. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in a uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation are discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  7. Diagnostic imaging of the diabetic foot

    International Nuclear Information System (INIS)

    Ranachowska, C.; Lass, P.; Korzon-Burakowska, A.; Dobosz, M.

    2010-01-01

    Diabetic foot syndrome is a significant complication of diabetes. Diagnostic imaging is a crucial factor determining surgical decision and extent of surgical intervention. At present the gold standard is MRI scanning, whilst the role of bone scanning is decreasing, although in some cases it brings valuable information. In particular, in early stages of osteitis and Charcot neuro-osteoarthropathy, radionuclide imaging may be superior to MRI. Additionally, a significant contribution of inflammation-targeted scintigraphy should be noted. Probably the role of PET scanning will grow, although its high cost and low availability may be a limiting factor. In every case, vascular status should be determined, at least with Doppler ultrasound, with following conventional angiography or MR angiography. (authors)

  8. High speed imaging system for nuclear diagnostics

    International Nuclear Information System (INIS)

    Eyer, H.H.

    1976-01-01

    A high speed imaging system based on state-of-the-art photosensor arrays has been designed for use in nuclear diagnostics. The system is comprised of a front-end rapid-scan solid-state camera, a high speed digitizer, and a PCM line driver in a downhole package and a memory buffer system in an uphole trailer. The downhole camera takes a ''snapshot'' of a nuclear device created flux stream, digitizes the image and transmits it to the uphole memory system before being destroyed. The memory system performs two functions: it retains the data for local display and processing by a microprocessor, and it buffers the data for retransmission at slower rates to the LLL computational facility (NADS). The impetus for such a system as well as its operation is discussed. Also discussed are new systems under development which incorporate higher data rates and more resolution

  9. Modern imaging technology for childhood urinary tract infection

    International Nuclear Information System (INIS)

    Riccabona, M.; Fotter, R.

    2005-01-01

    Imaging in childhood urinary tract infection (UTI) is still a matter of debate. There are established guidelines, however new knowledge and the changed medical environment have enhanced this ongoing discussion. These new insights have impacted therapy and consequently the imaging algorithm. Modern imaging methods - particularly MRI and modern ultrasound (US) - are less invasive with a lower radiation burden. Additionally, it has been shown that VUR is a poor predictor for renal scarring out, which affects long-term results. Furthermore, the majority of UT malformations is depicted by prenatal US. The most crucial aspect of improving long-term outcome appears to be the early and reliable depiction of UTI and effective treatment to prevent renal scarring. This review tries to present this new knowledge and to discuss the potential of modern imaging. Recent changes in imaging algorithms are highlighted and an outcome-oriented algorithm that addresses these recent developments is proposed, without lightly abandoning established standards. It consists of an orienting US and - for depiction of renal involvement - amplitude coded color Doppler sonography or renal static scintigraphy (considered the gold standard, particularly for evaluating scars); in future MRI may play a role. Based on this concept, only patients with renal damage as well as patients with complex urinary tract malformations or intractable recurrent UTI may have to undergo VCUG. (orig.) [de

  10. Companion diagnostics and molecular imaging-enhanced approaches for oncology clinical trials.

    Science.gov (United States)

    Van Heertum, Ronald L; Scarimbolo, Robert; Ford, Robert; Berdougo, Eli; O'Neal, Michael

    2015-01-01

    In the era of personalized medicine, diagnostic approaches are helping pharmaceutical and biotechnology sponsors streamline the clinical trial process. Molecular assays and diagnostic imaging are routinely being used to stratify patients for treatment, monitor disease, and provide reliable early clinical phase assessments. The importance of diagnostic approaches in drug development is highlighted by the rapidly expanding global cancer diagnostics market and the emergent attention of regulatory agencies worldwide, who are beginning to offer more structured platforms and guidance for this area. In this paper, we highlight the key benefits of using companion diagnostics and diagnostic imaging with a focus on oncology clinical trials. Nuclear imaging using widely available radiopharmaceuticals in conjunction with molecular imaging of oncology targets has opened the door to more accurate disease assessment and the modernization of standard criteria for the evaluation, staging, and treatment responses of cancer patients. Furthermore, the introduction and validation of quantitative molecular imaging continues to drive and optimize the field of oncology diagnostics. Given their pivotal role in disease assessment and treatment, the validation and commercialization of diagnostic tools will continue to advance oncology clinical trials, support new oncology drugs, and promote better patient outcomes.

  11. Diagnostic imaging of acute aortic dissection

    International Nuclear Information System (INIS)

    Ohya, Tohru; Kumazaki, Tatsuo

    1991-01-01

    One hundred and nineteen patients with aortic dissection who underwent diagnostic imaging were reviewed and angiographic findings as well as those of CT were analysed. Thirty eight cases (43.1%) had non-contrast opacified false lumen, the type of which we call 'thrombosed type aortic dissection'. A comparative study of the thrombosed type with the patent type of false lumens was made particularly from the stand point of the characteristic diagnostic imagings (CT and angiography). At the same time, the pitfalls of these imagings in thrombosed type aortic dissection were studied. At the onset the average age of thrombosed type was 62.3 years old, while that of the patent type was 57.3. A statistical significance between the two groups was p<0.05. Thrombosed type in all cases was caused by atherosclerosis, whereas patent type was caused by the Marfan's syndrome in 11 cases. Other clinical findings, such as initial symptoms and blood pressure revealed no significant differences between the two groups. Pre-contrast CT in acute thrombosed type aortic dissection showed 'hyperdense crescent sign' in 89.4%. However, in 3 cases with thrombosed type in which the pre-contrast CT showed 'hyperdense crescent sign' contrast-enhanced CT detected no clear evidence of aortic dissection in the same site. This was due to obscurity induced by contrast medium. Angiographic findings of thrombosed type were classified into 3 groups: normal type, stenosed true lumen type and ulcer-like projection type. The incidence of normal type was estimated to be 48.4%, whereas stenosed true lumen type was 24.2% and ulcer-like projection was 27.7%. The present study concluded that thrombosed type is not rare in acute aortic dissection and contrast-enhanced CT as well as pre-contrast CT, is of great value in diagnosing thrombosed type. 'Hyperdense crescent sign' in pre-contrast CT is characteristic of intramural hematoma. (author)

  12. Eagle Syndrome: diagnostic imaging and therapy

    International Nuclear Information System (INIS)

    Nickel, J.; Andresen, R.; Sonnenburg, M.; Scheufler, O.

    2004-01-01

    In the case of clinical symptoms such as dysphagia, foreign-body sensation and chronic neck or facial pain close to the ear, an Eagle syndrome should be considered in the differential diagnosis. Rational diagnostics and therapy are elucidated on the basis of four case reports. Four patients presented in the out-patients clinic with chronic complaints on chewing and a foreign-body sensation in the tonsil region. Upon specific palpation below the mandibular angle, pain radiating into the ear region intensified. In all patients, local anaesthesia with lidocaine only led to a temporary remission of symptoms. Imaging diagnostics then performed initially included cranial survey radiograms according to Clementschitsch as well as in the lateral ray path and an OPTG. An axial spiral-CT was then performed using the thin-layer technique with subsequent 3-D reconstruction. Therapy consisted of elective resection with a lateral external incision from the retromandibular. From a symptomatic point of view, the cranial survey radiograms and the OPTG revealed hypertrophic styloid processes. The geometrically corrected addition of the axial CT images produced an absolute length of 51-58 mm. The 3-D reconstruction made it possible to visualise the exact spatial orientation of the styloid processes. An ossification of the stylohyoid ligament could definitely be ruled out on the basis of the imaging procedures. After resection of the megastyloid, the patients were completely free of symptoms. Spiral-CT with subsequent 3-D reconstruction is the method of choice for exact determination of the localisation and size of a megastyloid, while cranial survey radiograms according to Clementschitsch and in the lateral ray path or an OPTG can provide initial information. The therapy of choice is considered to be resection of the megastyloid, whereby an external lateral incision has proved effective. (orig.) [de

  13. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  14. Image and Morphology in Modern Theory of Architecture

    Science.gov (United States)

    Yankovskaya, Y. S.; Merenkov, A. V.

    2017-11-01

    This paper is devoted to some important and fundamental problems of the modern Russian architectural theory. These problems are: methodological and technological retardation; substitution of the modern professional architectural theoretical knowledge by the humanitarian concepts; preference of the traditional historical or historical-theoretical research. One of the most probable ways is the formation of useful modern subject (and multi-subject)-oriented concepts in architecture. To get over the criticism and distrust of the architectural theory is possible through the recognition of an important role of the subject (architect, consumer, contractor, ruler, etc.) and direction of the practical tasks of the forming human environment in the today’s rapidly changing world and post-industrial society. In this article we consider the evolution of two basic concepts for the theory of architecture such as the image and morphology.

  15. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  16. Visible Imaging Diagnostic on Tore-Supra

    Energy Technology Data Exchange (ETDEWEB)

    Dachicourt, R.; Monier Garbet, P.; Beaute, A.; Habib-Naiim, M. [Association Euratom-CEA, CEA/DSM/IRFM, CEA Cadarache (France); Marandet, Y. [PIIM, CNRS-Universite de Provence, Marseille (France)

    2011-07-01

    Full text of publication follows: Research for thermonuclear fusion aims at energy production using fusion reactions between deuterium and tritium nuclei. To this end, a deuterium/tritium mixture has to be heated to a very high temperature (about 100 millions degrees). Chemical and physical sputtering erodes the plasma facing components (PFC), leading to an impurity influx to the plasma. Estimating this erosion source is important both for the PFC lifetime and the quality of the confinement. In fact, impurities reaching the plasma core radiate energy and dilute the fuel. In this contribution, we describe an erosion diagnostic operated on the Tore Supra tokamak, consisting in the combination of visible spectroscopy and filtered imaging over a full TPL (Toroidal Pumped Limiter) sector. Quantitative measurements of spectral lines brightness on four spectrometer chords monitoring the TPL top are used to process the corresponding filtered images, namely to remove background emission or unwanted lines. The particle influx from the TPL's vicinity is obtained from photon fluxes measurements [1], which require absolute calibration in intensity of the system. Filtered images provide the spatial pattern of erosion, from which the total eroded carbon flux is reconstructed. The variation of the particle influx with the input power is studied by analyzing a dedicated experimental campaign. References: [1] Behringer K. et al. Plasma Physics and Controlled Fusion, Vol. 31, No. 14, pp. 2059 to 2099, 1989. (authors)

  17. Diagnostic imaging and radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs.

  18. Diagnostic imaging and radiation therapy equipment

    International Nuclear Information System (INIS)

    1990-05-01

    This is the third edition of CSA Standard C22.2 No. 114 (now CAN/CSA-C22.2 No. 114), which is one of a series of standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. This edition marks an important shift towards harmonization of Canadian requirements with those of the European community and the United States. Also important to this edition is the expansion of its scope to include the complete range of diagnostic imaging and radiation therapy equipment, rather than solely radiation-emitting equipment. In so doing, equipment previously addressed by CSA Standard C22.2 No. 125, Electromedical Equipment, specifically lasers for medical applications and diagnostic ultrasound units, is now dealt with in the new edition. By virtue of this expanded scope, many of the technical requirements in the electromedical equipment standard have been introduced to the new edition, thereby bringing CSA Standard C22.2 No. 114 up to date. 14 tabs., 16 figs

  19. Diagnostic imaging of hypertrophic pyloric stenosis (HPS)

    International Nuclear Information System (INIS)

    Frkovic, M.; Seronja Kuhar, M.; Perhoc, Z.; Barbaric-Babic, V.; Molnar, M.; Vukovic, J.

    2001-01-01

    Background. Imaging of the abdomen in children with suspected hypertrophic pyloric stenosis has been traditionally performed by plain film radiography and upper gastrointestinal contrast studies. In many clinical situations, this approach has been modified or replaced by ultrasound examination. The authors aimed to analyse the value of diagnostic algorithm in children with hypertrophic pyloric stenosis confirmed at surgery in our hospital. Patients and methods. The authors made a five year retrospective review of hospital records of all children operated on for HPS in Clinical Hospital Centre Zagreb - Rebro and found out that 14 boys, between 2 (17 days) and 10 weeks of life (75 days) underwent surgery due to HPS. Results. Specific radiographic signs were: string sign, double track sign, elongation and narrowing of pyloric canal, mushroom sign, gastric distension with fluid and beak sign. Ultrasound was performed in 9 patients, one of them was false negative (sonographer admitted that he had no experience), the rest were positive. Conclusions. If the physical examination is negative or equivocal, sonography by an experienced sonographer must be performed. If the ultrasound finding is negative, than the infant should undergo to barium upper gastrointestinal studies (UGI). If HPS isn't a primary diagnostic question, it's better to perform UGI first in order to make a correct diagnosis. (author)

  20. Radiation exposure and image quality in x-Ray diagnostic radiology physical principles and clinical applications

    CERN Document Server

    Aichinger, Horst; Joite-Barfuß, Sigrid; Säbel, Manfred

    2012-01-01

    The largest contribution to radiation exposure to the population as a whole arises from diagnostic X-rays. Protecting the patient from radiation is a major aim of modern health policy, and an understanding of the relationship between radiation dose and image quality is of pivotal importance in optimising medical diagnostic radiology. In this volume the data provided for exploring these concerns are partly based on X-ray spectra, measured on diagnostic X-ray tube assemblies, and are supplemented by the results of measurements on phantoms and simulation calculations.

  1. Inside out: modern imaging techniques to reveal animal anatomy.

    OpenAIRE

    Henrik Lauridsen; Kasper Hansen; Tobias Wang; Peter Agger; Jonas L Andersen; Peter S Knudsen; Anne S Rasmussen; Lars Uhrenholt; Michael Pedersen

    2011-01-01

    Animal anatomy has traditionally relied on detailed dissections to produce anatomical illustrations, but modern imaging modalities, such as MRI and CT, now represent an enormous resource that allows for fast non-invasive visualizations of animal anatomy in living animals. These modalities also allow for creation of three-dimensional representations that can be of considerable value in the dissemination of anatomical studies. In this methodological review, we present our experiences using MRI,...

  2. Modern imaging technology for childhood urinary tract infection; Moderne Bildgebung beim Harnweginfekt im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M.; Fotter, R. [Radiologische Universitaetsklinik Graz (Germany). Abteilung Kinderradiologie

    2005-12-01

    Imaging in childhood urinary tract infection (UTI) is still a matter of debate. There are established guidelines, however new knowledge and the changed medical environment have enhanced this ongoing discussion. These new insights have impacted therapy and consequently the imaging algorithm. Modern imaging methods - particularly MRI and modern ultrasound (US) - are less invasive with a lower radiation burden. Additionally, it has been shown that VUR is a poor predictor for renal scarring out, which affects long-term results. Furthermore, the majority of UT malformations is depicted by prenatal US. The most crucial aspect of improving long-term outcome appears to be the early and reliable depiction of UTI and effective treatment to prevent renal scarring. This review tries to present this new knowledge and to discuss the potential of modern imaging. Recent changes in imaging algorithms are highlighted and an outcome-oriented algorithm that addresses these recent developments is proposed, without lightly abandoning established standards. It consists of an orienting US and - for depiction of renal involvement - amplitude coded color Doppler sonography or renal static scintigraphy (considered the gold standard, particularly for evaluating scars); in future MRI may play a role. Based on this concept, only patients with renal damage as well as patients with complex urinary tract malformations or intractable recurrent UTI may have to undergo VCUG. (orig.) [German] Die bildgebende Diagnostik beim kindlichen Harnweginfekt (HWI) wird weiterhin heftig diskutiert. Zwar existieren etablierte Bildgebungsalgorithmen, insbesondere fuer das Kleinkindesalter; neue Erkenntnisse bzw. Aufgabenstellungen haben aber zu einer Aenderung des Therapiekonzepts mit Auswirkungen auf die Bildgebung gefuehrt. Zusaetzlich haben technische (Weiter)Entwicklungen das Potenzial der Bildgebung erweitert; v. a. MRT und moderne Ultraschallverfahren versprechen eine weniger invasive und strahlenfreie

  3. Diagnostic Imaging and Problems of Schizencephaly

    International Nuclear Information System (INIS)

    Stopa, Joanna; Kucharska-Miąsik, Iwona; Dziurzyńska-Białek, Ewa; Kostkiewicz, Agnieszka; Solińska, Anna; Zając-Mnich, Monika; Guz, Wiesław; Samojedny, Antoni

    2014-01-01

    Schizencephaly is a rare developmental malformation of the central nervous system associated with cell migration disturbances. Schizencephaly can be uni- or bilateral and is divided into two morphological types. The cleft is defined as type I (“closed lips”) if there are fused clefts in cerebral mantle. In type II (“open lips”) the clefts are separated and filled with cerebrospinal fluid connecting lateral ventricle with the subarachnoid space. We retrospectively analysed data of patients hospitalized in the Clinical Pediatric Neurology Department of Provincial Hospital No. 2 in Rzeszow between 1998–2011. Clinical data and imaging exams were analysed in the group of children with confirmed schizencephaly. Schizencephaly was recognized in 32 children. Diagnosis was made in children at the ages between 2 weeks and 15 years – the majority of older children were born before the year 2000. Diagnostic imaging, most often magnetic resonance imaging, was performed in all of the children. In most cases coexistence of other CNS malformations was discovered. In only one patient there were no neurological symptoms, most of the children presented different developmental disorders and neurological symptoms – most often cerebral palsy and epilepsy. In the group of children with bilateral and type II schizencephaly certain symptoms occurred more often. Schizencephaly is a rare central nervous system developmental disorder, which is very often associated with other severe brain malformations and in most of the cases subsequent multiple neurological symptoms. The method of choice in diagnosis of schizencephaly is magnetic resonance, which shows the degree and type of cleft, coexisting abnormalities and allows differential diagnosis. With the increased availability of this method it is possible to recognize schizencephaly more often and earlier

  4. Basic artefacts of diagnostic imaging by the magnetic resonance method

    International Nuclear Information System (INIS)

    Vitak, T.; Seidl, Z.; Obenberger, J.; Vaneckova, M.; Danes, J.; Krasensky, J.; Peterkova, V

    2000-01-01

    Artefacts in diagnostic imaging are defined as a geometric or anatomic misrepresentation of the reality by the image formed. The article deals with artefacts due to field and frequency shifts, in particular due to the water-fat chemical shift and due to magnetic susceptibility. The physical nature of the artefacts is explained and their diagnostic significance is discussed. (P.A.)

  5. Imaging diagnostics of the foot; Bildgebende Diagnostik des Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Szeimies, Ulrike; Staebler, Axel [Radiologie in Muenchen-Harlaching, Muenchen (Germany); Walther, Markus (eds.) [Schoen-Klinik Muenchen-Harlaching, Muenchen (Germany). Zentrum fuer Fuss- und Sprunggelenkchirurgie

    2012-11-01

    The book on imaging diagnostics of the foot contains the following chapters: (1) Imaging techniques. (2) Clinical diagnostics. (3) Ankle joint and hind foot. (4) Metatarsus. (5) Forefoot. (6) Pathology of plantar soft tissue. (7) Nervous system diseases. (8) Diseases without specific anatomic localization. (9) System diseases including the foot. (10) Tumor like lesions. (11) Normative variants.

  6. MR imaging diagnostic protocol for unilocular lesions of the jaw

    Directory of Open Access Journals (Sweden)

    Hironobu Konouchi

    2012-08-01

    Using our MR imaging diagnostic protocol to diagnose 31 cases, we obtained a positivity rate of 71.0%. The use of our MR imaging diagnostic protocol for unilocular lesions, which are especially difficult to differentiate by radiography, would improve the morphological and qualitative diagnosis of soft tissue lesions.

  7. Analysis of licensed South African diagnostic imaging equipment ...

    African Journals Online (AJOL)

    Analysis of licensed South African diagnostic imaging equipment. ... Pan African Medical Journal ... Introduction: Objective: To conduct an analysis of all registered South Africa (SA) diagnostic radiology equipment, assess the number of equipment units per capita by imaging modality, and compare SA figures with published ...

  8. Roentgen signs in diagnostic imaging. Vol. 2

    International Nuclear Information System (INIS)

    Meschan, I.

    1988-01-01

    The introductory chapter presents terminology and definitions of current use in the field of roentgen pathology and also gives a short list of terms relating to the application of the novel imaging methods. The first chapter explains the fundamentals of radiological evaluation of the bone joints and skeleton, and chapters two and three discuss fractures and luxations of the extremities and the available treatment methods. The fourth chapter deals with congenital and hereditary bone lesions and the relevant roentgen signs such as reduced contrast or modifications in size or shape. The chapters five and six deal with specific bone lesions of a particular bone or skeletal area, or a particular extremity, also characterised by reduced contrast. Other bone lesions showing enhanced density, expansive processes or other massive change are discussed in chapter seven, and roen tgen signs of the bone joints in chapter eight. The last chapter deals with computed tomography for diagnostic evaluation of the appendicular skeleton. (MG) With 1803 figs., 29 tabs [de

  9. Ordering of diagnostic information in encoded medical images. Accuracy progression

    Science.gov (United States)

    Przelaskowski, A.; Jóźwiak, R.; Krzyżewski, T.; Wróblewska, A.

    2008-03-01

    A concept of diagnostic accuracy progression for embedded coding of medical images was presented. Implementation of JPEG2000 encoder with a modified PCRD optimization algorithm was realized and initially verified as a tool for accurate medical image streaming. Mean square error as a distortion measure was replaced by other numerical measures to revise quality progression according to diagnostic importance of successively encoded image information. A faster increment of image diagnostic importance during reconstruction of initial packets of code stream was reached. Modified Jasper code was initially tested on a set of mammograms containing clusters of microcalcifications and malignant masses, and other radiograms. Teleradiologic applications were considered as the first area of interests.

  10. Image diagnostic of colonic diseases - controversial questions

    International Nuclear Information System (INIS)

    Pomakov, P.; Rizov, A.; Stancheva, I.

    2013-01-01

    In the system of colonic diseases' diagnostic algorithm, fibrocolonoscopy (FCS) is defined as 'Golden Standard'. By this reason some X-ray diagnostic methods - irrigography, etc. are currently not being used in a number of health institutions. The aim of this study is a comparative analysis of FCS and irrigography diagnostic efficacy in various colonic diseases. For 10-years period, in cooperation with a gastroenterologist-gastroscopist, 2151 patients with various colonic diseases were evaluated by FCS and irrigography with pharmaco-diagnostics/when necessary. Advantage of FCS was established in diagnosing diseases with patho-morfologic changes on the inner surface of the colon - benign and malignant neoplastic processes, chronic inflammatory diseases, etc. At the same time functional changes - irritated colon syndrome, changes in defecation act, etc., are not an object of diagnosis through FCS. Correction in colonic diseases diagnostic algorithm is necessary. FCS should be mandatory. If result is negative - irrigography with pharmaco-diagnostics should be done. (authors)

  11. Diagnostic information management system for the evaluation of medical images

    Energy Technology Data Exchange (ETDEWEB)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina

    1985-04-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions.

  12. Diagnostic information management system for the evaluation of medical images

    International Nuclear Information System (INIS)

    Higa, Toshiaki; Torizuka, Kanji; Minato, Kotaro; Komori, Masaru; Hirakawa, Akina.

    1985-01-01

    A practical, small and low-cost diagnostic information management system has been developed for a comparative study of various medical imaging procedures, including ordinary radiography, X-ray computed tomography, emission computed tomography, and so forth. The purpose of the system is to effectively manage the original image data files and diagnostic descriptions during the various imaging procedures. A diagnostic description of each imaging procedure for each patient is made on a hand-sort punched-card with line-drawings and ordinary medical terminology and then coded and computerized using Index for Roentgen Diagnoses (American College of Radiology). A database management software (DB Master) on a personal computer (Apple II) is used for searching for patients' records on hand-sort punched-cards and finally original medical images. Discussed are realistic use of medical images and an effective form of diagnostic descriptions. (author)

  13. RANZAR Body Systems Framework of diagnostic imaging examination descriptors

    International Nuclear Information System (INIS)

    Pitman, Alexander D.; Penlington, Lisa; Doromal, Darren; Vukolova, Natalia; Slater, Gregory

    2014-01-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were ‘greyed out’. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities.

  14. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  15. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension. Bildgebende nuklearmedizinische Diagnostik bei arterieller Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B M; Linss, G

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.).

  16. Structured diagnostic imaging in patients with multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Rieger, J.; Rock, C.; Pfeifer, K.J.; Reiser, M.; Kanz, K.G.

    2002-01-01

    Purpose. Development of a concept for structured diagnostic imaging in patients with multiple trauma.Material and methods. Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented.Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality.Results. This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients.Conclusion. Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality. (orig.) [de

  17. Modern radiological postoperative diagnostics of the hip joint in children and adults

    International Nuclear Information System (INIS)

    Weber, M.A.; Thierjung, H.; Kloth, J.K.; Egermann, M.

    2015-01-01

    The assessment of bone healing and loosening of endoprosthesis material was long the primary indication for postoperative projection radiography and CT imaging of the hip joint following trauma and endoprosthesis implantation. With the increasing number of joint-preserving surgery, e. g. of surgical hip luxation and hip arthroscopy for the treatment of femoroacetabular impingement (FAI), high-resolution imaging of intra-articular pathologies before and after surgery has become increasingly important. In this review article, diagnostic imaging of the hip joint is presented following common trauma surgery and orthopedic surgery interventions. The imaging modalities of projection radiography, CT and MRI including direct MR-arthrography are discussed with regard to their diagnostic capability in the postoperative assessment of the hip joint. Among others topics, imaging is discussed following hip arthroplasty, following surgical hip luxation and arthroscopic interventions for the treatment of FAI, as well as following core decompression for avascular necrosis of the femoral head. Moreover, orthopedic interventions of the hip joint in children and adolescents are presented and the dedicated reporting of postoperative imaging is outlined.

  18. Strategic planning in diagnostic imaging: meeting the challenge.

    Science.gov (United States)

    Lexa, Frank J

    2008-02-01

    The 21st century has raised new and significant challenges to the practice of diagnostic imaging. Radiologists will have to navigate a difficult path as they face threats from disruptive technologies, adverse demographic changes, pressures to limit reimbursement both from the public and from the private sectors, increased domestic and crossborder competition, and many others. Success in these trying times will require greater attention to strategic planning if we are to thrive and survive in radiology. Strategic planning and tactical implementation methodologies were reviewed, from Sun Tzu to the present day, for applicability to the needs of modern radiology groups. A framework for developing and implementing strategic plans was constructed to assist radiology leaders and groups in considering the spectrum of tasks, from gathering intelligence, to developing scenarios, to implementing and evaluating tactical plans. Strategy and tactics are too important to be ignored or left to others. They need to be core activities for all radiology leaders. Frameworks can be used to help in providing structure and rigour to strategic planning efforts at the department and group level.

  19. Diagnostic imaging procedure volume in the United States

    International Nuclear Information System (INIS)

    Johnson, J.L.; Abernathy, D.L.

    1983-01-01

    Comprehensive data on 1979 and 1980 diagnostic imaging procedure volume were collected from a stratified random sample of U.S. short-term general-care hospitals and private practices of radiologists, cardiologists, obstetricians/gynecologists, orthopedic surgeons, and neurologists/neurosurgeons. Approximately 181 million imaging procedures (within the study scope) were performed in 1980. Despite the rapidly increasing use of newer imaging methods, plain film radiography (140.3 million procedures) and contrast studies (22.9 million procedures) continue to comprise the vast majority of diagnostic imaging volume. Ultrasound, computed tomography, nuclear medicine, and special procedures make up less than 10% of total diagnostic imaging procedures. Comparison of the data from this study with data from an earlier study indicates that imaging procedure volume in hospitals expanded at an annual growth rate of almost 8% from 1973 to 1980

  20. Overuse of Diagnostic Imaging for Work-Related Injuries.

    Science.gov (United States)

    Clendenin, Brianna Rebecca; Conlon, Helen Acree; Burns, Candace

    2017-02-01

    Overuse of health care in the United States is a growing concern. This article addresses the use of diagnostic imaging for work-related injuries. Diagnostic imaging drives substantial cost for increases in workers' compensation. Despite guidelines published by the American College of Radiology and the American College of Occupational Medicine and the Official Disability Guidelines, practitioners are prematurely ordering imaging sooner than recommended. Workers are exposed to unnecessary radiation and are incurring increasing costs without evidence of better outcomes. Practitioners caring for workers and submitting workers' compensation claims should adhere to official guidelines, using their professional judgment to consider financial impact and health outcomes of diagnostic imaging including computed tomography, magnetic resonance imaging, nuclear medicine imaging, radiography, and ultrasound.

  1. Fast, fat-suppressed diagnostic imaging of the breast

    International Nuclear Information System (INIS)

    Metzger, G.J.; Weatherall, P.

    1999-01-01

    Maximum sensitivity and diagnostic precision of MR imaging of the breast can be achieved only with fat-suppressed diagnostic scans with high resolution. Optimal results were obtained with a 3D-FFE sequence and excitation by a binomial pulse and an amplitude-modulated binomial pulse. (orig./CB) [de

  2. Diagnostic value of imaging in infective endocarditis : a systematic review

    NARCIS (Netherlands)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of

  3. Quantitative Methods for Molecular Diagnostic and Therapeutic Imaging

    OpenAIRE

    Li, Quanzheng

    2013-01-01

    This theme issue provides an overview on the basic quantitative methods, an in-depth discussion on the cutting-edge quantitative analysis approaches as well as their applications for both static and dynamic molecular diagnostic and therapeutic imaging.

  4. Spectroscopic and imaging diagnostics of pulsed laser deposition laser plasmas

    International Nuclear Information System (INIS)

    Thareja, Raj K.

    2002-01-01

    An overview of laser spectroscopic techniques used in the diagnostics of laser ablated plumes used for thin film deposition is given. An emerging laser spectroscopic imaging technique for the laser ablation material processing is discussed. (author)

  5. Methodology for quantitative evaluation of diagnostic medical imaging

    International Nuclear Information System (INIS)

    Metz, C.

    1980-01-01

    This report deals with the evaluation of the performance of diagnostic medical imaging procedures using the Receiver Operating Characteristic or ROC analysis. The development of new tests for the statistical significance of apparent differences between ROC curves is discussed

  6. Trends in utilization: has extremity MR imaging replaced diagnostic arthroscopy?

    International Nuclear Information System (INIS)

    Glynn, Nicole; Morrison, William B.; Parker, Laurence; Schweitzer, Mark E.; Carrino, John A.

    2004-01-01

    To examine the relative change in utilization of magnetic resonance (MR) imaging of the extremities versus diagnostic and therapeutic arthroscopy. Using the 1993, 1996, and 1999 nationwide Medicare Part B databases, utilization rates (per 100,000) were determined for upper and lower extremity MR imaging, diagnostic arthroscopy and therapeutic arthroscopy using CPT-4 codes. Utilization of extremity MR imaging was compared with that of diagnostic and therapeutic arthroscopy in 10 geographic regions of the United States and tracked over time. Combined lower and upper extremity MR imaging utilization per 100,000 increased from 393 to 1,056 in 1999 (+168.7%). Utilization of diagnostic arthroscopy of the extremities decreased from 18 in 1993 to 8 in 1999 (-55.6%); therapeutic arthroscopy rates increased from 461 in 1993 to 636 in 1999 (+40.0%). Specifically, from 1993 to 1999, utilization of lower extremity MR imaging increased from 270 to 661 (+144.8%). Utilization of diagnostic arthroscopy of the knee over the same time period decreased from 11 to 5 (-54.5%); therapeutic arthroscopy increased from 394 to 501 (+27.2%). Similarly, utilization rates for upper extremity MR imaging increased from 123 to 395 (+221.1%). Utilization of diagnostic arthroscopy of the shoulder over the same time period decreased from 7 to 2 (-71.4%); therapeutic arthroscopy increased from 44 to 104 (+136.4%). No specific geographic trends were ascertained. The utilization of MR imaging of the extremities has markedly increased from 1993 to 1999. During the same time period the utilization of diagnostic arthroscopy has decreased and that of therapeutic arthroscopy has increased. These findings support the hypothesis that there is increased reliance of clinical practitioners on the diagnostic information provided by MR imaging in preoperative clinical decision-making. (orig.)

  7. Application of Nanoparticles in Diagnostic Imaging via ...

    African Journals Online (AJOL)

    ... ability to image quantitatively both morphological and physiological functions of the tissue, ... Several types of contrast media are used in medical imaging and they can ... which is still widely used to examine internal organs of the body and ...

  8. Musculoskeletal desmoid tumours: Diagnostic imaging appearances

    International Nuclear Information System (INIS)

    Liu, Daniel; Perera, Warren; Schlicht, Stephen; Choong, Peter; Slavin, John; Pianta, Marcus

    2015-01-01

    This study aimed to discuss the role medical imaging has on diagnosis of musculoskeletal desmoid tumours and to describe their radiological appearances on various imaging modalities. Imaging of histologically proven cases of desmoid tumours at St. Vincent's Hospital Melbourne were obtained via picture archiving communication system (PACS) and then assessed by two musculoskeletal radiologists. Suitable imagings were obtained from PACS. All imaging chosen was de-identified. Desmoid tumours can occur in many areas of the body. Imaging plays an important role in the diagnosis of these tumours and magnetic resonance imaging has been the gold standard for imaging and is the most accurate in terms of assessing tumour margins and involvement of surrounding structure.

  9. Roentgen signs in diagnostic imaging. Vol. 1

    International Nuclear Information System (INIS)

    Meschan, I.

    1988-01-01

    This book is a new edition under a different title of a part of the three-volume publication 'Analysis of X-ray pictures'. The book primarily deals with X-ray diagnostics and covers four chapters on the following subjects: plain radiographs of the abdomen, the urinary tract, obstetrics including gynaecology, and the biliary tract. Diagnostic ultrasonography is discussed in greater detail in the chapter on obstetrics and gynaecology as it is a method of first choice in this field. (MG) With 944 figs., 33 tabs [de

  10. The design of diagnostic imaging and nuclear medicine facilities in a major new teaching hospital

    International Nuclear Information System (INIS)

    Causer, D.A.

    2010-01-01

    Full text: The design of the layout and radiation shielding for diagnostic imaging and nuclear medicine facilities in a modern teaching hospital requires the collaboration of persons from a number of professions including architects, engineers, radiologists, nuclear medicine physi cians, medical imaging technologists and medical physicists. This paper discusses the design of such facilities, including PET/CT and T-131 ablation therapy suites for a major new tertiary hospital in Perth. The importance of involving physicists on the planning team from the earliest stages of the design process is stressed, design plans presented, and some of the problems which may present themselves and their solutions are illustrated.

  11. A survey of medical diagnostic imaging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today's more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities.

  12. A survey of medical diagnostic imaging technologies

    Energy Technology Data Exchange (ETDEWEB)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today`s more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities.

  13. A survey of medical diagnostic imaging technologies

    International Nuclear Information System (INIS)

    Heese, V.; Gmuer, N.; Thomlinson, W.

    1991-10-01

    The fields of medical imaging and medical imaging instrumentation are increasingly important. The state-of-the-art continues to advance at a very rapid pace. In fact, various medical imaging modalities are under development at the National Synchrotron Light Source (such as MECT and Transvenous Angiography.) It is important to understand how these techniques compare with today's more conventional imaging modalities. The purpose of this report is to provide some basic information about the various medical imaging technologies currently in use and their potential developments as a basis for this comparison. This report is by no means an in-depth study of the physics and instrumentation of the various imaging modalities; instead, it is an attempt to provide an explanation of the physical bases of these techniques and their principal clinical and research capabilities

  14. A study of diagnostic imaging in pancreatic trauma

    International Nuclear Information System (INIS)

    Hirota, Masashi; Kanazumi, Naohito; Kato, Koichi; Eguchi, Takehiko; Kobayashi, Hironobu; Suzuki, Yuichi; Kimura, Jiro; Ishii, Masataka

    2002-01-01

    Pancreatic trauma treatment depends on pancreatic ductal injury. We examined the usefulness and problems of diagnostic imaging, such as enhanced CT, ERP, and CT after ERP, in pancreatic trauma. Subjects were 12 patients with pancreatic trauma treated in our hospital between April 1993 and March 2000. Enhanced CT was performed in 6 patients undergoing diagnostic imagings and ERP in 4 of the 6. Overall diagnostic accuracy of pancreatic ductal injury in enhanced CT was 16.7% and accuracy in ERP with CT after ERP was 100%. Intraoperative diagnosis of main pancreatic ductal injury was difficult in 1 of 2 patients in whom ERP failed. The importance of preoperative diagnostic imaging is thus clear. We expect that MRCP, recently evaluated in pancreatic disease diagnosis, will become a new pancreatic trauma modality. (author)

  15. diagnostic imaging of acute head trauma

    International Nuclear Information System (INIS)

    Prayer, D.; Rametsteiner, C.

    2001-01-01

    Computed tomography (CT) is the primary modality of choice for imaging patients with acute head trauma. Lesions of the soft tissues and of the bones can be assessed more precisely than with other imaging modalities. With magnetic resonance imaging (MRI) additional information may be gained especially in subacute and chronic posttraumatic conditions. Urgent indication to perform a CT examination depends on the patient's history and on the mechanism of trauma. Imaging interpretation has been performed in the context of typical pathologic effects of trauma and with respect to potential therapy. (author)

  16. Oncologic applications of diagnostic imaging techniques

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1995-01-01

    Before appropriate therapy can be instituted for a cancer patient, the presence and extent of tumor must be evaluated. Deciding which imaging technique to use depends on tumor location, type, and biologic behavior. Conventional radiography provides important information at a relatively low cost compared with other imaging modalities. Ultrasound is a valuable adjunct to radiography, but does not replace it because both imaging modalities provide unique information. Nuclear medicine procedures contribute additional, unique data by providing physiological information, but specificity is lacking. Both CT and MRI provide images with exquisite anatomic detail, but availability and cost prohibit their general use

  17. Diagnostic imaging in undergraduate medical education: an expanding role

    International Nuclear Information System (INIS)

    Miles, K.A.

    2005-01-01

    Radiologists have been involved in anatomy instruction for medical students for decades. However, recent technical advances in radiology, such as multiplanar imaging, 'virtual endoscopy', functional and molecular imaging, and spectroscopy, offer new ways in which to use imaging for teaching basic sciences to medical students. The broad dissemination of picture archiving and communications systems is making such images readily available to medical schools, providing new opportunities for the incorporation of diagnostic imaging into the undergraduate medical curriculum. Current reforms in the medical curriculum and the establishment of new medical schools in the UK further underline the prospects for an expanding role for imaging in medical education. This article reviews the methods by which diagnostic imaging can be used to support the learning of anatomy and other basic sciences

  18. Artificial intelligence as a diagnostic adjunct in cardiovascular nuclear imaging

    International Nuclear Information System (INIS)

    Duncan, J.S.

    1988-01-01

    The radiologist and/or nuclear medicine physician is literally bombarded with information from today's diagnostic imaging technologies. As a consequence of this, whereas a decade ago the emphasis in medical image analysis was on improving the extraction of diagnostic information by developing and using more sophisticated imaging modalities, today those working on the development of medical imaging technology are struggling to find ways to handle all gathered information effectively. This chapter gives an introduction to the area of artificial intelligence, with an emphasis on the research ongoing in cardiovascular nuclear imaging. This chapter has reviewed the place of artificial intelligence in cardiovascular nuclear imaging. It is intended to provide a general sense of this new and emerging field, an insight into some of its specific methodologies and applications, and a closer look at the several AI approaches currently being applied in cardiovascular nuclear imaging

  19. Radiation exposure from diagnostic imaging among patients with gastrointestinal disorders.

    LENUS (Irish Health Repository)

    Desmond, Alan N

    2012-03-01

    There are concerns about levels of radiation exposure among patients who undergo diagnostic imaging for inflammatory bowel disease (IBD), compared with other gastrointestinal (GI) disorders. We quantified imaging studies and estimated the cumulative effective dose (CED) of radiation received by patients with organic and functional GI disorders. We also identified factors and diagnoses associated with high CEDs.

  20. Preparing diagnostic 3D images for image registration with planning CT images

    International Nuclear Information System (INIS)

    Tracton, Gregg S.; Miller, Elizabeth P.; Rosenman, Julian; Chang, Sha X.; Sailer, Scott; Boxwala, Azaz; Chaney, Edward L.

    1997-01-01

    Purpose: Pre-radiotherapy (pre-RT) tomographic images acquired for diagnostic purposes often contain important tumor and/or normal tissue information which is poorly defined or absent in planning CT images. Our two years of clinical experience has shown that computer-assisted 3D registration of pre-RT images with planning CT images often plays an indispensable role in accurate treatment volume definition. Often the only available format of the diagnostic images is film from which the original 3D digital data must be reconstructed. In addition, any digital data, whether reconstructed or not, must be put into a form suitable for incorporation into the treatment planning system. The purpose of this investigation was to identify all problems that must be overcome before this data is suitable for clinical use. Materials and Methods: In the past two years we have 3D-reconstructed 300 diagnostic images from film and digital sources. As a problem was discovered we built a software tool to correct it. In time we collected a large set of such tools and found that they must be applied in a specific order to achieve the correct reconstruction. Finally, a toolkit (ediScan) was built that made all these tools available in the proper manner via a pleasant yet efficient mouse-based user interface. Results: Problems we discovered included different magnifications, shifted display centers, non-parallel image planes, image planes not perpendicular to the long axis of the table-top (shearing), irregularly spaced scans, non contiguous scan volumes, multiple slices per film, different orientations for slice axes (e.g. left-right reversal), slices printed at window settings corresponding to tissues of interest for diagnostic purposes, and printing artifacts. We have learned that the specific steps to correct these problems, in order of application, are: Also, we found that fast feedback and large image capacity (at least 2000 x 2000 12-bit pixels) are essential for practical application

  1. Image quality enhancement for skin cancer optical diagnostics

    Science.gov (United States)

    Bliznuks, Dmitrijs; Kuzmina, Ilona; Bolocko, Katrina; Lihachev, Alexey

    2017-12-01

    The research presents image quality analysis and enhancement proposals in biophotonic area. The sources of image problems are reviewed and analyzed. The problems with most impact in biophotonic area are analyzed in terms of specific biophotonic task - skin cancer diagnostics. The results point out that main problem for skin cancer analysis is the skin illumination problems. Since it is often not possible to prevent illumination problems, the paper proposes image post processing algorithm - low frequency filtering. Practical results show diagnostic results improvement after using proposed filter. Along that, filter do not reduces diagnostic results' quality for images without illumination defects. Current filtering algorithm requires empirical tuning of filter parameters. Further work needed to test the algorithm in other biophotonic applications and propose automatic filter parameter selection.

  2. [Real time diagnostics of instantaneous temperature of combustion and explosion process by modern spectroscopy].

    Science.gov (United States)

    Zhou, Xue-tie; Wang, Jun-de; Li, Yan; Liu, Da-bing

    2003-04-01

    The combustion temperature is one of the important parameters to express flame combustion and explosion characteristics. It will effectively guide the design and manufacture of new model explosives, industrial explosive materials, and weapons. The recent developments and applications of real time diagnostics of instantaneous temperature of combustion and explosion processes by modern spectroscopic methods, such as atomic absorption-emission method, atomic emission two-line spectroscopy, atomic emission multiline spectroscopy, molecular rotation-vibration spectroscopy, coherent anti-stokes Raman scattering (CARS) and plane laser-induced fluorescence (PLIF), were reviewed in this paper. The maximum time resolution of atomic absorption-emission method is 25 microseconds. The time resolution of atomic emission two-line spectroscopy can reach 0.1 microsecond. These two methods can completely suit the need of real time and instantaneous temperature diagnostics of violent explosion and flame combustion. Other methods will also provide new effective research methods for the processes and characteristics of combustion, flame and explosion.

  3. RANZCR Body Systems Framework of diagnostic imaging examination descriptors.

    Science.gov (United States)

    Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia

    2014-08-01

    A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.

  4. Diagnostic imaging analysis of the impacted mesiodens

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Jeong Jun; Choi, Bo Ram; Jeong, Hwan Seok; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2010-06-15

    The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

  5. Diagnostic imaging of the hand. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Schmitt, R.

    2004-01-01

    The second edition contains the following new features: Focus on cogenital, degenerative, inflammatory, tumourous, neurogenic and vascular diseases of the hands; new images of multiline spiral CT including 2D pictures and 3D reconstructions; new MRT images with examination protocols; synoptic presentation of all diseases according to their pathoanatomy, clinical symptoms, diagnostic imaging, differential diagnosis, therapeutic options; checklists for the doctor's everyday work. (orig.)

  6. Modern

    Directory of Open Access Journals (Sweden)

    A.V. Bagrov

    2014-06-01

    Full Text Available The article gives an overview of the most important problems of modern meteoric astronomy and briefly describes ways and methods of their solutions. Particular attention is paid to the construction and arrangement of meteoric video cameras intended for registration of the meteoric phenomena as the main method of obtaining reliable and objective observational data on the basis of which the solution of the described tasks is possible.

  7. Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum

    Energy Technology Data Exchange (ETDEWEB)

    Kainberger, F.; Kletter, K. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2007-11-15

    Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

  8. Digital image acquisition in the X-ray diagnostics. Its influence on the patients' exposure

    International Nuclear Information System (INIS)

    Hoberg, Bernd; Voigt, Stefan

    2012-01-01

    Radiation exposure in the classical X-ray diagnostics was continuously reduced during the past years. The annual report 2009 of the Bundesamt fuer Strahlenschutz (BfS) shows that 46% of the radiological examinations in Germany concern the skeleton, the lungs and the digestive and urogenital tract. The respective radiation dose is only 20% of the total dose of the public from X-ray diagnostic measures. Considering computerized tomography, angiography and interventional radiology, that amount to about 10% of the radiological examinations, their dose percentage reaches about 80%. Therefore, the emphasis of modern radiation protection has to be targeted to digital techniques in the future X-ray diagnostics. The authors describe digital detectors, direct and indirect digitalized image receivers, flat-panel detectors and dynamic detectors.

  9. Augmented Reality: Advances in Diagnostic Imaging

    Directory of Open Access Journals (Sweden)

    David B. Douglas

    2017-11-01

    Full Text Available In recent years, advances in medical imaging have provided opportunities for enhanced diagnosis and characterization of diseases including cancer. The improved spatial resolution provides outstanding detail of intricate anatomical structures, but has challenged physicians on how to effectively and efficiently review the extremely large datasets of over 1000 images. Standard volume rendering attempts to tackle this problem as it provides a display of 3D information on a flat 2D screen, but it lacks depth perception and has poor human–machine interface (HMI. Most recently, Augmented Reality/Virtual Reality (AR/VR with depth 3-dimensional (D3D imaging provides depth perception through binocular vision, head tracking for improved HMI and other key AR features. In this article, we will discuss current and future medical applications of AR including assessing breast cancer. We contend that leveraging AR technology may enhance diagnosis, save cost and improve patient care.

  10. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  11. Patient dose with quality image under diagnostic reference levels

    International Nuclear Information System (INIS)

    Akula, Suresh Kumar; Singh, Gurvinder; Chougule, Arun

    2016-01-01

    Need to set Diagnostic Reference Level (DRL) for locations for all diagnostic procedures in local as compared to National. The review of DRL's should compare local with national or referenced averages and a note made of any significant variances to these averages and the justification for it. To survey and asses radiation doses to patient and reduce the redundancy in patient imaging to maintain DRLs

  12. Electronic viewbox: An integrated image diagnostic working station

    International Nuclear Information System (INIS)

    Minato, K.; Komori, M.; Hirakawa, A.; Kuwahara, M.; Yonekura, Y.; Torizuka, K.; Brill, A.B.

    1985-01-01

    Recent development in medical imaging technology have been introducing variety of digital images in clinical medicine, and handling these multi-modality digital images in one place is needed for efficient clinical diagnosis. The authors proposed a concept of an integrated image diagnostic working station, in which a physician can look into all clinical images, can select any key image for diagnosis and can read it in detail. A prototype working station named ''Electronic Viewbox'' has been developed for this purpose. It has three distinctive features. 1. The stored images of a patient are shown at a glance. In order to achieve this function, each original image is attached to a small image, where the data are compressed to reserve the essence of the image, and many of these small images are displayed on a CRT screen. This small image is used as an index for picking up a key image in the archived clinical images. 2. The working station is compact enough to be set on a desk. Only two CRTs and a pointing device are assembled. These two CRT screens are used mutually for retrieving key images and for displaying the original images. 3. All operations can be done interactively using cursor and icons

  13. Diagnostic imaging of craniofacial trauma and fractures and their sequelae

    International Nuclear Information System (INIS)

    Buitrago-Tellez, C.H.; Kunz, C.

    2001-01-01

    The value and applications of the CT modalities are on the rise, particularly since the availability of spiral CT techniques, while conventional native diagnostics is increasingly used for special imaging purposes. Multiplanar spiral CT enables high-quality coronary 2D reconstructions which, in the acute phase, make redundant primary coronary imaging modalities. Exact knowledge of typical fracture patterns facilitates the analysis of images of the relevant facial areas. 3D reconstructions are indispensable in pin-pointed surgery planning, generation of stereolithographic models, and image-guided interventions for examination of post-traumatic deformities. Since a secondary correction only very rarely leads to restitutio ad integrum, it is necessary to detect the therapy-relevant injuries very early, during acute diagnostic imaging, in order to lay the basis for subsequent therapy and restoration of the craniofacial structures and functions. (orig./CB) [de

  14. The "Diagnostic and Statistical Manual of Mental Disorders" as a Major Form of Dehumanization in the Modern World

    Science.gov (United States)

    Gambrill, Eileen

    2014-01-01

    The "Diagnostic and Statistical Manual of Mental Disorders" (DSM) is one of the most successful technologies in modern times. In spite of well-argued critiques, the DSM and the idea of "mental illness" on which it is based flourish, with ever more (mis)behaviors labeled as brain diseases. Problems in living and related distress…

  15. Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

    Science.gov (United States)

    Grudzińska, Ewa; Modrzejewska, Monika

    2018-01-01

    Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.

  16. Diagnostic imaging of tibial periosteal ganglion

    International Nuclear Information System (INIS)

    Valls, R.; Melloni, P.; Darnell, A.; Munoz, J.; Canalies, J.

    1997-01-01

    A case of a soft tissue tumor situated in the anterior surface of the proximal end of the tibia in an adult patient is demonstrated by conventional radiographs, CT, and MRI. The lesion was well defined with respect to the adjacent soft tissue. The CT exam showed a soft tissue mass with external cortical erosion and thick spicules by periosteal reaction. On T1-weighted images the mass was homogeneous and of low signal intensity, whereas on T2-weighted images it showed a high signal intensity, with some septa in the mass. The differential considerations include a periosteal chondroma, a lipoma, a subperiosteal hematoma, an inflammatory process, a giant cell tumor of tendon sheath, and a parosteal osteosarcoma. The CT and MR features of these entities are reviewed as an aid in differential diagnosis of the periosteal ganglion. (orig.). With 4 figs

  17. Diagnostic imaging in companion animal theriogenology

    International Nuclear Information System (INIS)

    Root, C.R.; Spaulding, K.A.

    1994-01-01

    Clinical assessment of reproductive problems in companion animals is greatly enhanced by the availability of various imaging modalities. Specifically, survey radiography, contrast radiography, real-time ultrasonography, and ultrasound-guided biopsy and/or aspiration cytology, alone or in various combinations, offer sophisticated methods of extension of the physical examination of the reproductive systems of dogs and cats. In particular, real-time ultrasonography offers invaluable assistance. It is nonionizing, largely noninvasive, rapid, and capable of providing certain dynamic information that is not conveniently available in any other way. Judging from its rapid growth in recent years, it has apparently become an integral part of the complete reproductive assessment of domestic animals. This is not to slight the importance of some of the contrast radiographic procedures that have been developed and refined. Some of them, such as maximum distention retrograde urothrocystography, provide unique information not available with presently routinely used ultrasound techniques. Other imaging modalities, such as magnetic resonance imaging, have heretofore provided limited benefit to theriogenology; that will probably change in years to come

  18. Plenoptic Imaging for Three-Dimensional Particle Field Diagnostics.

    Energy Technology Data Exchange (ETDEWEB)

    Guildenbecher, Daniel Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hall, Elise Munz [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-06-01

    Plenoptic imaging is a promising emerging technology for single-camera, 3D diagnostics of particle fields. In this work, recent developments towards quantitative measurements of particle size, positions, and velocities are discussed. First, the technique is proven viable with measurements of the particle field generated by the impact of a water drop on a thin film of water. Next, well cont rolled experiments are used to verify diagnostic uncertainty. Finally, an example is presented of 3D plenoptic imaging of a laboratory scale, explosively generated fragment field.

  19. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  20. Diagnostic imaging of lymphoma of the kidney

    International Nuclear Information System (INIS)

    Grzesiakowska, U.; Smorczewska, M.; Huczynska-Szubert, E.

    2010-01-01

    Purpose. The aim of this paper is to discuss both the clinical and radiological signs and the diagnostic principles of lymphomatous infiltrations of the kidney. Materials and methods. The studied group consisted of 20 patients (9 women, 11 men) aged 18-79 years. The follows-up varied from 2 to 156 months. All patients underwent CT and ultrasound investigations, while only 1 patient had an MRI examination. In 7 cases surgical treatment was performed, while the remaining 13 patients received chemotherapy. One patient died, 12 are in remission and seven are under observation and considered cured. Results. The radiological signs of kidney lymphoma may be divided into groups: a) kidney enlargement, obliteration of the cortex-core differentiation and obliteration of the outline; b) heterogenous kidney structure with undefined hypodense fociand lack of enhancement after the administration of contrasting material; c) presence of a well-defined tumor within the renal pelvis and external infiltration of the kidney, d) infiltration of the kidney originating from the retroperitoneal space encompassing the organ from the outside. Conclusions. The radiological signs of lymphoma differ in the kidney and exhibit a characteristic set of features. Radiology results combined with clinical symptoms may suggest lymphoma in the kidney and thus advocate the necessity of pathological evaluation prior to surgical treatment. (authors)

  1. Quality Assurance Tests for Modern Optical Imaging Systems

    Science.gov (United States)

    Cole, R.W.; Stack, R.F.

    2010-01-01

    r10-1 Modern light microscopes are highly evolved opto-electronic-mechanical devices, most costing in the 100′s of thousands of dollars.The days of simply be being able to ascertain instrument performance by looking through the eye pieces at a specimen are gone.However, users as well as granting agencies need to be confident that data collected will be uniform and quantifiable both over time on the same instrument andfrom instrument to instrument.We have conducted the first stage of a world-wide research study on instrument performance utilizing three image-based tests.The goal of this study was not to compare the performance of different brands of instruments, nor to ascertain which brand had better performance in a given area.Simply, the aims of the study were: to ascertain the current state of light microscopes through simple and efficient, yet robust tests and to develop relative standards that will assist core managers and/or users in maintaining their instruments in optimal operating conditions. In an ideal world, a LASER would not fluctuate, illumination would be completely uniform and all colors would perfectly align.The tests selected were: long and short term stability tests of illumination sources, uniformity of field illumination, and co-localization across various wavelengths. There were instances where data from a single microscope was within range for some tests but not for all.There were other instances where single microscopes meet all or conversely none of the expected performance levels.From this data it is obvious that all three tests need to be performed on a regular basis to assure high fidelity data.

  2. Diagnostic value of imaging in infective endocarditis: a systematic review.

    Science.gov (United States)

    Gomes, Anna; Glaudemans, Andor W J M; Touw, Daan J; van Melle, Joost P; Willems, Tineke P; Maass, Alexander H; Natour, Ehsan; Prakken, Niek H J; Borra, Ronald J H; van Geel, Peter Paul; Slart, Riemer H J A; van Assen, Sander; Sinha, Bhanu

    2017-01-01

    Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review to critically appraise the evidence for the diagnostic performance of these imaging modalities, according to PRISMA and GRADE criteria. We searched PubMed, Embase, and Cochrane databases. 31 studies were included that presented original data on the performance of electrocardiogram (ECG)-gated multidetector CT angiography (MDCTA), ECG-gated MRI, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET/CT, and leucocyte scintigraphy in diagnosis of native valve endocarditis, intracardiac prosthetic material-related infection, and extracardiac foci in adults. We consistently found positive albeit weak evidence for the diagnostic benefit of 18 F-FDG PET/CT and MDCTA. We conclude that additional imaging techniques should be considered if infective endocarditis is suspected. We propose an evidence-based diagnostic work-up for infective endocarditis including these non-invasive techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Coherence imaging spectro-polarimetry for magnetic fusion diagnostics

    International Nuclear Information System (INIS)

    Howard, J

    2010-01-01

    This paper presents an overview of developments in imaging spectro-polarimetry for magnetic fusion diagnostics. Using various multiplexing strategies, it is possible to construct optical polarization interferometers that deliver images of underlying physical parameters such as flow speed, temperature (Doppler effect) or magnetic pitch angle (motional Stark and Zeeman effects). This paper also describes and presents first results for a new spatial heterodyne interferometric system used for both Doppler and polarization spectroscopy.

  4. Diagnostic imaging of the nose and paranasal sinuses

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.

    1988-01-01

    This book offers extensively illustrated and comprehensive coverage of diagnostic imaging techniques of the nose and paranasal sinuses. The important feature of the work is the way it correlates histology with CT and MRI and includes magnetic resonance contrast studies using Gadolinium DTPA. Furthermore, it is the first text to treat the imaging of the various types of tumors of the nose and paranasal sinuses on an individual basis

  5. Diagnostic imaging of pulmonary lymphangiosis carcinomatosa

    International Nuclear Information System (INIS)

    Rehbock, B.; Hieckel, H.G.

    2004-01-01

    The diagnosis of pulmonary lymphangiosis carcinomatosa (PLC) is of great importance for the prognostically-oriented therapy stratification of tumor patients. In this field, high-resolution computed tomography (HRCT) is the state of the art in imaging. Using HRCT, it is possible to identify pulmonary parenchymal structures in a detailed fashion to evaluate interstitial patterns. This step is preceded by an x-ray of the thorax that detects pathological findings and rules out other diseases. The typical characteristics of PLC are described with particular attention to HR-phenomenology, and discussed in comparison with the literature regarding anatomy and pathogenesis. Finally, conclusions are drawn for differential diagnosis and supported by characteristic cases. (orig.) [de

  6. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  7. Microwave imaging for plasma diagnostics and its applications

    International Nuclear Information System (INIS)

    Mase, A.; Kogi, Y.; Ito, N.

    2007-01-01

    Microwave to millimeter-wave diagnostic techniques such as interferometry, reflectometry, scattering, and radiometry have been powerful tools for diagnosing magnetically confined plasmas. Important plasma parameters were measured to clarify the physics issues such as stability, wave phenomena, and fluctuation-induced transport. Recent advances in microwave and millimeter-wave technology together with computer technology have enabled the development of advanced diagnostics for visualization of 2D and 3D structures of plasmas. Microwave/millimeter-wave imaging is expected to be one of the most promising diagnostic methods for this purpose. We report here on the representative microwave diagnostics and their industrial applications as well as application to magnetically-confined plasmas. (author)

  8. MRI-based diagnostic imaging of the intratemporal facial nerve

    International Nuclear Information System (INIS)

    Kress, B.; Baehren, W.

    2001-01-01

    Detailed imaging of the five sections of the full intratemporal course of the facial nerve can be achieved by MRI and using thin tomographic section techniques and surface coils. Contrast media are required for tomographic imaging of pathological processes. Established methods are available for diagnostic evaluation of cerebellopontine angle tumors and chronic Bell's palsy, as well as hemifacial spasms. A method still under discussion is MRI for diagnostic evaluation of Bell's palsy in the presence of fractures of the petrous bone, when blood volumes in the petrous bone make evaluation even more difficult. MRI-based diagnostic evaluation of the idiopatic facial paralysis currently is subject to change. Its usual application cannot be recommended for routine evaluation at present. However, a quantitative analysis of contrast medium uptake of the nerve may be an approach to improve the prognostic value of MRI in acute phases of Bell's palsy. (orig./CB) [de

  9. [EYECUBE as 3D multimedia imaging in macular diagnostics].

    Science.gov (United States)

    Hassenstein, Andrea; Scholz, F; Richard, G

    2011-11-01

    In the new generation of EYECUBE devices, the angiography image and the OCT are included in a 3D illustration as an integration. Other diagnostic procedures such as autofluorescence and ICG can also be correlated to the OCT. The aim was to precisely classify various two-dimensional findings in relation to each other. The new generation of OCT devices enables imaging with a low incidence of motion artefacts with very good fundus image quality - and with that, permits a largely automatic classification. The feature enabling the integration of the EYECUBE was further developed with new software, so that not only the topographic image (red-free, autofluorescence) can be correlated to the Cirrus OCT, but also all other findings gathered within the same time frame can be correlated to each other. These were brightened and projected onto the cube surface in a defined interval. The imaging procedures can be selected in a menu toolbar. Topographic volumetry OCT images can be overlayed. The practical application of the new method was tested on patients with macular disorders. By lightening up the results from various diagnostic procedures, it is possible of late to directly compare pathologies to each other and to the OCT results. In all patients (n = 45 eyes) with good single-image quality, the automated integration into the EYECUBE was possible (to a great extent). The application is not dependent on a certain type of device used in the procedures performed. The increasing level of precision in imaging procedures and the handling of large data volumes has led to the possibility of examining each macular diagnostics procedure from the comparative perspective: imaging (photo) with perfusion (FLA, ICG) and morphology (OCT). The exclusion of motion artefacts and the reliable scan position in the course of the imaging process increases the informative value of OCT. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Radiology and diagnostic images in the gastric cancer

    International Nuclear Information System (INIS)

    Duarte, Alfonso; Acosta, Nelson; Alvarez R, Alfonso and others

    1992-01-01

    This article deals with the chapter about diagnostic imaging included in the document of the first practical seminar about gastric carcinoma which took place at Betania (Huila) in the first few days of April 1992. This seminar was organized by the Colombian society of gastroenterology in coordination with other organization

  11. Present practice of diagnostic imaging in the newborn infants

    International Nuclear Information System (INIS)

    Akamatsu, Hiroshi

    1994-01-01

    The present practice of diagnostic imaging in our NICU (which includes premature unit) was studied, surveying the total 637 admitted newborn infants during the year of 1992. The total number of diagnostic imaging performed other than scout radiography was 939. The number of ultrasonography of the heart and the brain, and brain CT was 752 or 80.0% of the total. These were done more frequently in the cases of very low birth weight infants. In our NICU, ultrasonography including pulse-doppler method, is performed for diagnosis of structural and functional abnormality of the cardiopulmonary systems and also for finding intracranial lesion, on the basis of finding in plain chest films. In spite of various limitation, we are performing, as the necessity commands, fluoroscopic contrast study, angiography, scintigraphy and MRI for the low birth weight (≥1,500g) and mature infants. Some of the actual cases in which diagnostic imaging was helpful were presented. Recently, upon admittance to the NICU for the specific abnormality of the newborn and premature infants, orginally, asymptomatic diseases are often found and diagnosed. This should be the results of progress in diagnostic imaging in recent years. (author)

  12. Magnetic resonance imaging of the wrist: Diagnostic performance statistics

    International Nuclear Information System (INIS)

    Hobby, Jonathan L.; Tom, Brian D.M.; Bearcroft, Philip W.P.; Dixon, Adrian K.

    2001-01-01

    AIM: To review the published diagnostic performance statistics for magnetic resonance imaging (MRI) of the wrist for tears of the triangular fibrocartilage complex, the intrinsic carpal ligaments, and for osteonecrosis of the carpal bones. MATERIALS AND METHODS: We used Medline and Embase to search the English language literature. Studies evaluating the diagnostic performance of MRI of the wrist in living patients with surgical confirmation of MR findings were identified. RESULTS: We identified 11 studies reporting the diagnostic performance of MRI for tears of the triangular fibrocartilage complex for a total of 410 patients, six studies for the scapho-lunate ligament (159 patients), six studies for the luno-triquetral ligament (142 patients) and four studies (56 patients) for osteonecrosis of the carpal bones. CONCLUSIONS: Magnetic resonance imaging is an accurate means of diagnosing tears of the triangular fibrocartilage and carpal osteonecrosis. Although MRI is highly specific for tears of the intrinsic carpal ligaments, its sensitivity is low. The diagnostic performance of MRI in the wrist is improved by using high-resolution T2* weighted 3D gradient echo sequences. Using current imaging techniques without intra-articular contrast medium, magnetic resonance imaging cannot reliably exclude tears of the intrinsic carpal ligaments. Hobby, J.L. (2001)

  13. Diagnostic imaging of shoulder rotator cuff lesions

    Directory of Open Access Journals (Sweden)

    Nogueira-Barbosa Marcello Henrique

    2002-01-01

    Full Text Available Shoulder rotator cuff tendon tears were evaluated with ultrasonography (US and magnetic resonance imaging (MRI. Surgical or arthroscopical correlation were available in 25 cases. Overall costs were also considered. Shoulder impingement syndrome diagnosis was done on a clinical basis. Surgery or arthroscopy was considered when conservative treatment failure for 6 months, or when rotator cuff repair was indicated. Ultrasound was performed in 22 patients and MRI in 17 of the 25 patients. Sensitivity, specificity and accuracy were 80%, 100% and 90.9% for US and 90%, 100% and 94.12% for MRI, respectively. In 16 cases both US and MRI were obtained and in this subgroup statistical correlation was excellent (p< 0.001. We concluded that both methods are reliable for rotator cuff full thickness tear evaluation. Since US is less expensive, it could be considered as the screening method when rotator cuff integrity is the main question, and when well trained radiologists and high resolution equipment are available.

  14. The improvement of diagnostic and therapeutic imaging in Africa

    International Nuclear Information System (INIS)

    2015-02-01

    The 8. Pan-African Congress of Radiology and Imaging on the improvement of diagnostic and therapeutic imaging in Africa was hosted in Nairobi Kenya. The conference focusses on Review of Radiation Safety in Medical X-Ray Diagnosis, Medical Practitioners of Radiology & Imaging in the Dock. It also addresses issues Knowledge, Attitude, and Practice of Clinicians, Practicing at the Kenyatta National Hospital on Ionizing Radiation and Procurement in the Imaging Department. The Need for Understanding Technical Specifications,Students Experience in Radiography, Radioiodine Therapy for Graves’ Disease, Role of ultrasound in the diagnosis and management of gestational trophoblastic disease in Rural health facilities were areas interest. Diabetes Mellitus and the Musculoskeletal System, Imaging the Traumatized Spine ‘Clearing the Cervical Spine’, The Radiation Safety Culture: Image Gently and Radiation Protection of the Young Patient: Kenya perspective were discussed during the conference

  15. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  16. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  17. Diagnostic imaging in psychiatry; Bildgebende Verfahren in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Stoppe, G.; Hentschel, F.; Munz, D.L. (eds.)

    2000-07-01

    The textbook presents an exhaustive survey of diagnostic imaging methods available for clinical evaluation of the entire range of significant psychiatric symptoms via imaging of the anatomy and functions of the brain. The chapters discuss: The methods and their efficient use for given diagnostic objectives, image analysis, description and interpretation of findings with respect to the clinical symptoms. Morphology and functional correlation of findings. The book is intended to help psychiatrists and neurologists as well as doctors in the radiology and nuclear medicine departments. (orig./CB) [German] Die Entwicklung der modernen Bildgebung ermoeglicht faszinierende Einblicke in Anatomie und Funktionen des Gehirns und ihre Veraenderungen bei psychiatrischen Erkrankungen. Die Methodik der Untersuchungsverfahren und die Befunde bei allen wichtigen psychiatrischen Krankheitsbildern sind in diesem Buch systematisch und umfassend beschrieben: - gezielter und effizienter Einsatz der Verfahren, - Bildanalyse und Befundbeschreibung, - Bewertung der Befunde und Beziehung zum klinischen Bild, - morphologische und funktionelle Korrelate der Befunde. Psychiater und Neurologen werden ebenso angesprochen wie Radiologen und Nuklearmediziner. (orig.)

  18. Image quality - physical and diagnostic parameters. The radiologist's viewpoint

    International Nuclear Information System (INIS)

    Stender, H.St.

    1985-01-01

    The quality of a radiograph is determined by the diagnostic information it provides. This depends upon the visual detection of diagnostically relevant structures. The technical radiographic requirements are dependent upon the physical measurements and the physiological and optical conditions. Such physical factors as spatial resolution, contrast and noise are quantitative measurements, which must be oriented to the qualitative visual characteristics of the radiograph. The influence of subjective perception and complexity of structural noise on the detectability of details and structures particularly demands attention. Since radiographic quality depends upon the detection of diagnostically relevant structure and features, it is important to define these parameters on the basis of extensive radiographic analysis and the corresponding clinical findings. The diagnostically relevant radiographic parameters and image details and critical structures have been worked out for the examination of the lungs, colon, stomach, urinary tract and skeleton. Good image quality requires coordination of the physical-technical parameters with the visual ability of the observer, since only in this way can the diagnostic information be represented with sufficient clarity. (author)

  19. Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

    OpenAIRE

    Dobrescu, Lidia; Rădulescu, Gheorghe-Cristian

    2015-01-01

    The paper presents many facets of medical imaging investigations radiological risks. The total volume of prescribed medical investigations proves a serious lack in monitoring and tracking of the cumulative radiation doses in many health services. Modern radiological investigations equipment is continuously reducing the total dose of radiation due to improved technologies, so a decrease in per caput dose can be noticed, but the increasing number of investigations has determined a net increase ...

  20. Image standards in Tissue-Based Diagnosis (Diagnostic Surgical Pathology

    Directory of Open Access Journals (Sweden)

    Vollmer Ekkehard

    2008-04-01

    Full Text Available Abstract Background Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. Aims To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. Theory and experiences Images used in tissue-based diagnosis present with pathology – specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease – image combination, human – diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image

  1. Electronic roentgenographic images in presurgical X-ray diagnostics

    International Nuclear Information System (INIS)

    Haendle, J.; Hohmann, D.; Maass, W.; Siemens A.G., Erlangen

    1981-01-01

    An essential part of radiation exposure in surgery is due to devices and results from the required radiation time interval for continuous X-ray play-back up to the point at which all diagnostically relevant information can be retrieved from the screening image. With single-image storage and short exposure times as well as instant image play-back, this superfluous i.e. redundant radiation can be avoided. The electronic X-ray image is realized by means of a laboratory prototype and evaluated in hospitals. There is a report on clinical results and new technical developments. Remarkable are: the high radiation reduction that could be obtained, the problem - free instant image technique, and especially the advantages of automated exposure in direct film settings. The positive results yield the basis for the product development. (orig./MG) [de

  2. Combining a thermal-imaging diagnostic with an existing imaging VISAR diagnostic at the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Robert M, Malone; John R, Celesteb; Peter M, Celliers; Brent C, Froggeta; Robert L, Guyton; Morris I, Kaufman; Tony L, Lee; Brian J, MacGowan; Edmund W, Ng; Imants P, Reinbachs; Ronald B, Robinson; Lynn G, Seppala; Tom W, Tunnell; Phillip W, Watts

    2005-01-01

    Optical diagnostics are currently being designed to analyze high-energy density physics experiments at the National Ignition Facility (NIF). Two independent line-imaging Velocity Interferometer System for Any Reflector (VISAR) interferometers have been fielded to measure shock velocities, breakout times, and emission of targets having sizes of 1-5 mm. An 8-inch-diameter, fused silica triplet lens collects light at f/3 inside the 30-foot-diameter NIF vacuum chamber. VISAR recordings use a 659.5-nm probe laser. By adding a specially coated beam splitter to the interferometer table, light at wavelengths from 540 to 645 nm is spilt into a thermal-imaging diagnostic. Because fused silica lenses are used in the first triplet relay, the intermediate image planes for different wavelengths separate by considerable distances. A corrector lens on the interferometer table reunites these separated wavelength planes to provide a good image. Thermal imaging collects light at f/5 from a 2-mm object placed at Target Chamber Center (TCC). Streak cameras perform VISAR and thermal-imaging recording. All optical lenses are on kinematic mounts so that pointing accuracy of the optical axis may be checked. Counter-propagating laser beams (orange and red) are used to align both diagnostics. The red alignment laser is selected to be at the 50 percent reflection point of the beam splitter. This alignment laser is introduced at the recording streak cameras for both diagnostics and passes through this special beam splitter on its way into the NIF vacuum chamber

  3. Diagnostic imaging of the hand. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Schmitt, Rainer; Lanz, Ulrich

    2015-01-01

    The book on diagnostic imaging of the hand covers the following issues: projection radiography, cinematography, MRT and CR arthrography, arthroscopy, arteriography, skeleton scintiscanning, sonography, computerized tomography, magnetic resonance tomography, anatomy of forearm and carpus, anatomy of metacarpus and fingers, carpal function and morphometry, postoperative X-ray diagnostic, growing hand skeleton, normative variants, malformations and deformities, trauma of the distal forearm, lesions of the ulnocarpal complex (TFCC), scaphoid fractures, scaphoid arthrosis, fractures of other carpus bones, carpal luxations and luxation fractures, carpal instabilities, fractures of the metacarpalla, finger fractures, arthrosis deformans, enthesiopathies, sport induced soft tissue lesions, osteonecrosis, impingement syndromes, osteopenic skeletal diseases, metabolis diseases, crystal-induced osteoarthropaties, rheumatoid arthritis, spondyloarthritis, rheumatic fever, collagenoses, infective arthritis, osteomyelitis, soft tissue infections, cystoids bone lesions, skeletal tumors, soft tissue tumors, carpal tunnel syndrome, nerve compression syndrome, arterial perfusion disturbances, differential diagnostic tables on hand lesions.

  4. Imaging mammary diagnostics. Diagnostic techniques, archetypical findings, differential diagnostcs and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Heywang-Koebrunner, S.; Schreer, I.

    2008-01-01

    The book includes the following chapters: I. Methodology: anamnesis and interview; clinical evidence, mammography, sonography, magnetic resonance tomography, new imaging techniques (scintigraphy, PET), transcutaneous biopsy, pre-operative marking; II. phenotypes: normal mammary glands, mastopathics, cysts, benign tumors, inflammatory diseases, in-situ carcinomas, invasive carcinomas, lymphomas, other semi-malign and malign tumors, post-traumatic, post-surgical and post-therapeutic changes, skin changes, male mamma, screening, continuative diagnostics of screening evidence and problem solving for symptomatic patients

  5. Modern radiological postoperative diagnostics of the hip joint in children and adults; Moderne radiologische postoperative Diagnostik des Hueftgelenks im Kindes- und Erwachsenenalter

    Energy Technology Data Exchange (ETDEWEB)

    Weber, M.A.; Thierjung, H.; Kloth, J.K. [Heidelberg University Hospital (Germany). Diagnostic and Interventional Radiology; Egermann, M. [Heidelberg University Hospital (Germany). Center for Orthopedics

    2015-07-15

    The assessment of bone healing and loosening of endoprosthesis material was long the primary indication for postoperative projection radiography and CT imaging of the hip joint following trauma and endoprosthesis implantation. With the increasing number of joint-preserving surgery, e. g. of surgical hip luxation and hip arthroscopy for the treatment of femoroacetabular impingement (FAI), high-resolution imaging of intra-articular pathologies before and after surgery has become increasingly important. In this review article, diagnostic imaging of the hip joint is presented following common trauma surgery and orthopedic surgery interventions. The imaging modalities of projection radiography, CT and MRI including direct MR-arthrography are discussed with regard to their diagnostic capability in the postoperative assessment of the hip joint. Among others topics, imaging is discussed following hip arthroplasty, following surgical hip luxation and arthroscopic interventions for the treatment of FAI, as well as following core decompression for avascular necrosis of the femoral head. Moreover, orthopedic interventions of the hip joint in children and adolescents are presented and the dedicated reporting of postoperative imaging is outlined.

  6. Diagnostics of materials and structures of heating system as a component of ecological management in a modern city

    Directory of Open Access Journals (Sweden)

    Verstina Natalia

    2016-01-01

    Full Text Available The maintenance of materials and structures of the underground space in modern cities which contains many engineering structures is considered in the article. It is claimed on the example of quantitative data that the underground structures exert a great influence on the ecological situation of the city. The matters of the research included the analysis of the main heating systems as the most responsible city structure; the conclusions obtained can be also used for smaller heat pipelines. The article includes the comparisons of modern technical methods of diagnostics of materials and heating systems structures according to the results of experiment, as well as the characteristic of norms of control of the materials condition at the stages of construction and maintenance applied in the developed countries. On this basis, the author has developed and presented a system of diagnostics taking into account the alternation of measures during the heating period as well as the season when heat supply is not required. For an effective ecological management in modern cities, it is suggested to create the automated data base of materials and structures of the heating systems on the basis of the developed scheme of their conditions and events, which needs to be used for forecasting of environmental risks and planning of recovery works with consideration of special features of the maintenance processes. The direction of the further research is defined: it is the expansion of the stated approaches on other types of underground communications in modern cities.

  7. Synthetic Microwave Imaging Reflectometry diagnostic using 3D FDTD Simulations

    Science.gov (United States)

    Kruger, Scott; Jenkins, Thomas; Smithe, David; King, Jacob; Nimrod Team Team

    2017-10-01

    Microwave Imaging Reflectometry (MIR) has become a standard diagnostic for understanding tokamak edge perturbations, including the edge harmonic oscillations in QH mode operation. These long-wavelength perturbations are larger than the normal turbulent fluctuation levels and thus normal analysis of synthetic signals become more difficult. To investigate, we construct a synthetic MIR diagnostic for exploring density fluctuation amplitudes in the tokamak plasma edge by using the three-dimensional, full-wave FDTD code Vorpal. The source microwave beam for the diagnostic is generated and refelected at the cutoff surface that is distorted by 2D density fluctuations in the edge plasma. Synthetic imaging optics at the detector can be used to understand the fluctuation and background density profiles. We apply the diagnostic to understand the fluctuations in edge plasma density during QH-mode activity in the DIII-D tokamak, as modeled by the NIMROD code. This work was funded under DOE Grant Number DE-FC02-08ER54972.

  8. A Versatile Image Processor For Digital Diagnostic Imaging And Its Application In Computed Radiography

    Science.gov (United States)

    Blume, H.; Alexandru, R.; Applegate, R.; Giordano, T.; Kamiya, K.; Kresina, R.

    1986-06-01

    In a digital diagnostic imaging department, the majority of operations for handling and processing of images can be grouped into a small set of basic operations, such as image data buffering and storage, image processing and analysis, image display, image data transmission and image data compression. These operations occur in almost all nodes of the diagnostic imaging communications network of the department. An image processor architecture was developed in which each of these functions has been mapped into hardware and software modules. The modular approach has advantages in terms of economics, service, expandability and upgradeability. The architectural design is based on the principles of hierarchical functionality, distributed and parallel processing and aims at real time response. Parallel processing and real time response is facilitated in part by a dual bus system: a VME control bus and a high speed image data bus, consisting of 8 independent parallel 16-bit busses, capable of handling combined up to 144 MBytes/sec. The presented image processor is versatile enough to meet the video rate processing needs of digital subtraction angiography, the large pixel matrix processing requirements of static projection radiography, or the broad range of manipulation and display needs of a multi-modality diagnostic work station. Several hardware modules are described in detail. For illustrating the capabilities of the image processor, processed 2000 x 2000 pixel computed radiographs are shown and estimated computation times for executing the processing opera-tions are presented.

  9. Optique moderne et post-moderne dans la composition d'images transculturelles dans trois films de Woody Allen

    Directory of Open Access Journals (Sweden)

    Nadia Fuchs

    2010-12-01

    Full Text Available Avec le personnage récurrent juif new-yorkais névrosé plus ou moins autobiographique, les films de Woody Allen ont créé, volontairement ou pas, leur propre mythologie et un genre à part entière composé de codes que le spectateur décrypte instantanément. Pourtant, Woody Allen est surtout un cinéaste post-moderne, analysant et déconstruisant les simulacres de son époque. Il est ainsi un passeur d'images retraçant l'histoire des arts modernes des XXe et XXIe siècles et de leurs stratégies énonciatives et réceptives.With the recurrent persona of the neurotic and more or less autobiographical Jewish New Yorker, Woody Allen's films have created, willingly or not, their own mythology and a specific genre made up of codes readily accessible to the spectator. However, Woody Allen is more than anything else a postmodern filmmaker who analyses and deconstructs the simulacra of his time. He is thus a conveyor of images which retrace the history of modern art of the XXth and XXIth centuries, and of their strategies of enunciation and reception.

  10. Cancer imaging phenomics toolkit: quantitative imaging analytics for precision diagnostics and predictive modeling of clinical outcome.

    Science.gov (United States)

    Davatzikos, Christos; Rathore, Saima; Bakas, Spyridon; Pati, Sarthak; Bergman, Mark; Kalarot, Ratheesh; Sridharan, Patmaa; Gastounioti, Aimilia; Jahani, Nariman; Cohen, Eric; Akbari, Hamed; Tunc, Birkan; Doshi, Jimit; Parker, Drew; Hsieh, Michael; Sotiras, Aristeidis; Li, Hongming; Ou, Yangming; Doot, Robert K; Bilello, Michel; Fan, Yong; Shinohara, Russell T; Yushkevich, Paul; Verma, Ragini; Kontos, Despina

    2018-01-01

    The growth of multiparametric imaging protocols has paved the way for quantitative imaging phenotypes that predict treatment response and clinical outcome, reflect underlying cancer molecular characteristics and spatiotemporal heterogeneity, and can guide personalized treatment planning. This growth has underlined the need for efficient quantitative analytics to derive high-dimensional imaging signatures of diagnostic and predictive value in this emerging era of integrated precision diagnostics. This paper presents cancer imaging phenomics toolkit (CaPTk), a new and dynamically growing software platform for analysis of radiographic images of cancer, currently focusing on brain, breast, and lung cancer. CaPTk leverages the value of quantitative imaging analytics along with machine learning to derive phenotypic imaging signatures, based on two-level functionality. First, image analysis algorithms are used to extract comprehensive panels of diverse and complementary features, such as multiparametric intensity histogram distributions, texture, shape, kinetics, connectomics, and spatial patterns. At the second level, these quantitative imaging signatures are fed into multivariate machine learning models to produce diagnostic, prognostic, and predictive biomarkers. Results from clinical studies in three areas are shown: (i) computational neuro-oncology of brain gliomas for precision diagnostics, prediction of outcome, and treatment planning; (ii) prediction of treatment response for breast and lung cancer, and (iii) risk assessment for breast cancer.

  11. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  12. Software for 3D diagnostic image reconstruction and analysis

    International Nuclear Information System (INIS)

    Taton, G.; Rokita, E.; Sierzega, M.; Klek, S.; Kulig, J.; Urbanik, A.

    2005-01-01

    Recent advances in computer technologies have opened new frontiers in medical diagnostics. Interesting possibilities are the use of three-dimensional (3D) imaging and the combination of images from different modalities. Software prepared in our laboratories devoted to 3D image reconstruction and analysis from computed tomography and ultrasonography is presented. In developing our software it was assumed that it should be applicable in standard medical practice, i.e. it should work effectively with a PC. An additional feature is the possibility of combining 3D images from different modalities. The reconstruction and data processing can be conducted using a standard PC, so low investment costs result in the introduction of advanced and useful diagnostic possibilities. The program was tested on a PC using DICOM data from computed tomography and TIFF files obtained from a 3D ultrasound system. The results of the anthropomorphic phantom and patient data were taken into consideration. A new approach was used to achieve spatial correlation of two independently obtained 3D images. The method relies on the use of four pairs of markers within the regions under consideration. The user selects the markers manually and the computer calculates the transformations necessary for coupling the images. The main software feature is the possibility of 3D image reconstruction from a series of two-dimensional (2D) images. The reconstructed 3D image can be: (1) viewed with the most popular methods of 3D image viewing, (2) filtered and processed to improve image quality, (3) analyzed quantitatively (geometrical measurements), and (4) coupled with another, independently acquired 3D image. The reconstructed and processed 3D image can be stored at every stage of image processing. The overall software performance was good considering the relatively low costs of the hardware used and the huge data sets processed. The program can be freely used and tested (source code and program available at

  13. Diagnostic Imaging of Reproductive Tract Disorders in Reptiles.

    Science.gov (United States)

    Gumpenberger, Michaela

    2017-05-01

    Diagnostic imaging of the reproductive tract in reptiles is used for gender determination, evaluation of breeding status, detection of pathologic changes, and supervising treatment. Whole-body radiographs provide an overview and support detection of mineralized egg shells. Sonography is used to evaluate follicles, nonmineralized eggs, and the salpinx in all reptiles. Computed tomography is able to overcome imaging limitations in chelonian species. This article provides detailed information about the performance of different imaging techniques. Multiple images demonstrate the physiologic appearance of the male and female reproductive tract in various reptile species and pathologic changes. Advantages and disadvantages of radiography, sonography, and computed tomography are described. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Diagnostic radiology of apoplexy - imaging of cerebral ischemia

    International Nuclear Information System (INIS)

    Rieber, A.; Tomczak, R.; Brambs, H.J.

    1998-01-01

    The recent enhancements achieved in CT and MR imaging techniques have launched a debate about the techniques preferrably to be applied for diagnostic evaluation of acute cerebral stroke. At present, CT still is the modality of choice for primary evaluation of cerebral ischemia, due to relative cost-effectiveness, high availability, and the capability to reliably differentiate ischemia from hemorrhage. MRI on the other hand is superior to CT in detecting and imaging the infarction area within the first few hours, especially if the technique of diffusion-weighted sequencing is applied. Current research focuses on determining whether MRI with perfusion and diffusion-weighted sequencing will yield images distinctly showing the penumbra on the one hand, and the damaged brain tissue on the other. It remains to be seen whether improved tomographic imaging will lead to novel approaches for therapy. (orig./CB) [de

  15. Traumatic cervical root injury: Diagnostic value of MR imaging

    International Nuclear Information System (INIS)

    Lee, Seon Kyu; Chang, Kee Hyun; Han, Moon Hee; Kim, Ho Chul; Kim, Jea Seung; Cha, Sang Hoon

    1993-01-01

    Although superior soft tissue contrast and direct multiplanar imaging capability of MRI are well recognized, myelography has been the imaging modality of choice in evaluation cervical root injury. We assessed the role of MRI and compared its diagnostic accuracy with myelography in the evaluation of cervical root injury. MR imagings of cervical root injury in ten patients (55 roots) were retrospectively reviewed. In 26 explored roots (6 patients). MR findings were compared with myelography and surgical results. In 29 roots (8 patients), which were confirmed by myelography or exploration, the MR findings were focal extradural CSF collections (pseudomeningocele) in 21/29 (72.4%, 8 patients), thickening of extradural roots in 4/29 (13.6%, 5 patients), and thickening of dura in 12/29 (41.4%, 6 patients) roots. T2-weighted axial image was superior to T1-weighted and protein-density- weighted images for delineation root avulsion. The sensitivity and specificity of MRI were 72.7% and 93.3% respectively, while those of myelography were 83% and 90%. Overall diagnostic accuracy of MRI and myelography were comparable (84.6% vs 87.5%). In conclusion, myelography is still considered as the modality of choice in the preoperative evaluation of the cervical root avulsion because of its higher sensitivity. MRI, however, may obviate the myelography with some technical refinements

  16. Parkinson's disease: diagnostic utility of volumetric imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Che; Chen, Meng-Hsiang [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); Chou, Kun-Hsien [National Yang-Ming University, Brain Research Center, Taipei (China); Lee, Pei-Lin [National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Tsai, Nai-Wen; Lu, Cheng-Hsien [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Neurology, Kaohsiung (China); Chen, Hsiu-Ling [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Diagnostic Radiology, Kaohsiung (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China); Hsu, Ai-Ling [National Taiwan University, Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Huang, Yung-Cheng [Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Department of Nuclear Medicine, Kaohsiung (China); Lin, Ching-Po [National Yang-Ming University, Brain Research Center, Taipei (China); National Yang-Ming University, Department of Biomedical Imaging and Radiological Sciences, Taipei (China)

    2017-04-15

    This paper aims to examine the effectiveness of structural imaging as an aid in the diagnosis of Parkinson's disease (PD). High-resolution T{sub 1}-weighted magnetic resonance imaging was performed in 72 patients with idiopathic PD (mean age, 61.08 years) and 73 healthy subjects (mean age, 58.96 years). The whole brain was parcellated into 95 regions of interest using composite anatomical atlases, and region volumes were calculated. Three diagnostic classifiers were constructed using binary multiple logistic regression modeling: the (i) basal ganglion prior classifier, (ii) data-driven classifier, and (iii) basal ganglion prior/data-driven hybrid classifier. Leave-one-out cross validation was used to unbiasedly evaluate the predictive accuracy of imaging features. Pearson's correlation analysis was further performed to correlate outcome measurement using the best PD classifier with disease severity. Smaller volume in susceptible regions is diagnostic for Parkinson's disease. Compared with the other two classifiers, the basal ganglion prior/data-driven hybrid classifier had the highest diagnostic reliability with a sensitivity of 74%, specificity of 75%, and accuracy of 74%. Furthermore, outcome measurement using this classifier was associated with disease severity. Brain structural volumetric analysis with multiple logistic regression modeling can be a complementary tool for diagnosing PD. (orig.)

  17. Development of an EMC3-EIRENE Synthetic Imaging Diagnostic

    Science.gov (United States)

    Meyer, William; Allen, Steve; Samuell, Cameron; Lore, Jeremy

    2017-10-01

    2D and 3D flow measurements are critical for validating numerical codes such as EMC3-EIRENE. Toroidal symmetry assumptions preclude tomographic reconstruction of 3D flows from single camera views. In addition, the resolution of the grids utilized in numerical code models can easily surpass the resolution of physical camera diagnostic geometries. For these reasons we have developed a Synthetic Imaging Diagnostic capability for forward projection comparisons of EMC3-EIRENE model solutions with the line integrated images from the Doppler Coherence Imaging diagnostic on DIII-D. The forward projection matrix is 2.8 Mpixel by 6.4 Mcells for the non-axisymmetric case we present. For flow comparisons, both simple line integral, and field aligned component matrices must be calculated. The calculation of these matrices is a massive embarrassingly parallel problem and performed with a custom dispatcher that allows processing platforms to join mid-problem as they become available, or drop out if resources are needed for higher priority tasks. The matrices are handled using standard sparse matrix techniques. Prepared by LLNL under Contract DE-AC52-07NA27344. This material is based upon work supported by the U.S. DOE, Office of Science, Office of Fusion Energy Sciences. LLNL-ABS-734800.

  18. Dose and diagnostic image quality in digital tomosynthesis imaging of facial bones in pediatrics

    Science.gov (United States)

    King, J. M.; Hickling, S.; Elbakri, I. A.; Reed, M.; Wrogemann, J.

    2011-03-01

    The purpose of this study was to evaluate the use of digital tomosynthesis (DT) for pediatric facial bone imaging. We compared the eye lens dose and diagnostic image quality of DT facial bone exams relative to digital radiography (DR) and computed tomography (CT), and investigated whether we could modify our current DT imaging protocol to reduce patient dose while maintaining sufficient diagnostic image quality. We measured the dose to the eye lens for all three modalities using high-sensitivity thermoluminescent dosimeters (TLDs) and an anthropomorphic skull phantom. To assess the diagnostic image quality of DT compared to the corresponding DR and CT images, we performed an observer study where the visibility of anatomical structures in the DT phantom images were rated on a four-point scale. We then acquired DT images at lower doses and had radiologists indicate whether the visibility of each structure was adequate for diagnostic purposes. For typical facial bone exams, we measured eye lens doses of 0.1-0.4 mGy for DR, 0.3-3.7 mGy for DT, and 26 mGy for CT. In general, facial bone structures were visualized better with DT then DR, and the majority of structures were visualized well enough to avoid the need for CT. DT imaging provides high quality diagnostic images of the facial bones while delivering significantly lower doses to the lens of the eye compared to CT. In addition, we found that by adjusting the imaging parameters, the DT effective dose can be reduced by up to 50% while maintaining sufficient image quality.

  19. Radiation exposure and image quality in X-ray diagnostic radiology. Physical principles and clinical applications. 2. ed.

    International Nuclear Information System (INIS)

    Saebel, Manfred; Aichinger, Horst; Dierker, Joachim; Joite-Barfuss, Sigrid

    2012-01-01

    Diagnostic X-rays are the largest contributor to radiation exposure to the general population, and protecting the patient from radiation damage is a major aim of modern health policy. Once the decision has been taken to use ionising radiation for imaging in a particular patient, it is necessary to optimize the image acquisition process taking into account the diagnostic quality of the images and the radiation dose to the patient. Both image quality and radiation dose are affected by a number of parameters, knowledge of which permits scientifically based decision making. The authors of this second edition of Radiation Exposure and Image Quality in X-ray Diagnostic Radiology have spent many years studying the optimization of radiological imaging. In this book they present in detail the basic physical principles of diagnostic radiology and their application to clinical problems. Particular attention is devoted to evaluation of the dose to the patient, the influence of scattered radiation on image quality, the use of antiscatter grids, and optimization of image quality and dose. The final section is a supplement containing tables of data and graphical depictions of X-ray spectra, interaction coefficients, characteristics of X-ray beams, and other aspects relevant to patient dose calculations. In addition, a complementary CD-ROM contains a user-friendly Excel file database covering these aspects that can be used in the reader's own programs. Since the first edition, the text, figures, tables, and references have all been thoroughly updated, and more detailed attention is now paid to image quality and radiation exposure when using digital imaging and computed tomography. This book will be an invaluable aid to medical physicists when performing calculations relating to patient dose and image quality, and will also prove useful for diagnostic radiologists and engineers. (orig.)

  20. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  1. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  2. Strategic planning for radiology: opening an outpatient diagnostic imaging center.

    Science.gov (United States)

    Leepson, Evan

    2003-01-01

    Launching a new diagnostic imaging center involves very specific requirements and roadmaps, including five major areas of change that have a direct impact on planning: Imaging and communication technology Finances and reimbursement Ownership structure of imaging entities Critical workforce shortages Imaging is moving outside radiology First, planning must focus on the strategic level of any organization, whether it is a multi-national corporation or a six-person radiology group. Think of all organizations as a triangle with three horizontal levels: strategic, managerial and operational. The strategic level of decision-making is at the top of the triangle, and here is where planning must take place. For strategic planning to work, there must be focused time and energy spent on this activity, usually away from the reading room and imaging center. There are five planning strategies, which must have the explicit goal of developing and growing the imaging center. The five strategies are: Clinical and quality issues, Governance and administration, Technology, Relationships, Marketing and business development. The best way to plan and implement these strategies is to create work groups of radiologists, technologists, and administrative and support staff. Once the group agrees on the strategy and tactic, it takes responsibility for implementation. Embarking on the launch of a new outpatient diagnostic imaging center is no small undertaking, and anyone who has struggled with such an endeavor can readily attest to the associated challenges and benefits. Success depends on many things, and one of the most important factors relates to the amount of time and the quality of effort spent on strategic planning at the outset. Neglecting or skimping on this phase may lead to unforeseen obstacles that could potentially derail the project.

  3. The clinician's guide to diagnostic imaging: Cost effective pathways

    International Nuclear Information System (INIS)

    Grossman, Z.D.; Chew, F.S.; Ellis, D.A.; Brigham, S.C.

    1987-01-01

    This book presents logical, step-by-step imaging sequences for 47 medical, surgical, and pediatric problems. Topics considered include breast cancer screening, acute spinal trauma, search for primary cancer of unknown origin, acute anuria, blunt chest trauma, new onset seizures, and spinal cord compression from metastases. Other chapters have been rewritten to enhance the clarity of presentation and to incorporate new techniques such as magnetic resonance imaging, dipyridamole stress testing, and single photon emission computed tomography. The book highlights the expanding role of CT in evaluation of thoracic and abdominal problems, the emergence of magnetic resonance imaging as a vital diagnostic tool for the central nervous system, and the clinical utility of many newly developed radiopharmaceuticals

  4. Overuse of trauma in sports - clinical signs in the context with modern imaging techniques

    International Nuclear Information System (INIS)

    Wurnig, C.; Gollob, E.

    2001-01-01

    New insights in the fields of pathology and diagnostic radiology of sports injuries show that the borders between overuse syndromes and trauma are blurred. Techniques of diagnostic imaging are increasingly important for an objective documentation of morphologic changes of the musculoskeletal system. Typical sports-related syndromes exist and their clinical diagnosis is not always easy because pain cannot be located exactly. (author)

  5. The potential capacities of Ta'ziyeh in Modern Imagism

    Directory of Open Access Journals (Sweden)

    A.M Nedai

    2009-03-01

    Full Text Available Ta'ziyeh as the most important method in religious and ritual theatre in Iran has many capabilities which can be used in modern visualization. The only element in this theatre which has been studied is distancing in performance styles. But by studying the existent versions of Ta'ziyehs, there are other elements for recognition and use, which has not still been studied. The relationship between religious and ritual theatre with Ta'ziyeh and also their main themes helps to identify these elements and their capabilities. Meanwhile, the presence of music as an expressive and performing element provides a basis which can be used in finding a new manner of expression in visual/dramatic works (such as music videos. Studying on such elements as time-place interlace, character replacement, functions of music, and their effects on audiences, shows that Ta'ziyeh has specific capabilities in visualization (even in Cinema and Media. This article, through capitalizing on this subject and introducing one paradigm (Moses and poor Pilgrim, and comparing two versions of it, tries to represent these capabilities, and illuminates Ta'ziyeh's abilities for modern (and even postmodern visualization.

  6. Visualization, imaging and new preclinical diagnostics in radiation oncology

    International Nuclear Information System (INIS)

    Cyran, Clemens C; Reiser, Maximilian F; Belka, Claus; Niyazi, Maximilian; Paprottka, Philipp M; Eisenblätter, Michel; Clevert, Dirk A; Rist, Carsten; Nikolaou, Konstantin; Lauber, Kirsten; Wenz, Frederik; Hausmann, Daniel

    2014-01-01

    Innovative strategies in cancer radiotherapy are stimulated by the growing knowledge on cellular and molecular tumor biology, tumor pathophysiology, and tumor microenvironment. In terms of tumor diagnostics and therapy monitoring, the reliable delineation of tumor boundaries and the assessment of tumor heterogeneity are increasingly complemented by the non-invasive characterization of functional and molecular processes, moving preclinical and clinical imaging from solely assessing tumor morphology towards the visualization of physiological and pathophysiological processes. Functional and molecular imaging techniques allow for the non-invasive characterization of tissues in vivo, using different modalities, including computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, positron emission tomography (PET) and optical imaging (OI). With novel therapeutic concepts combining optimized radiotherapy with molecularly targeted agents focusing on tumor cell proliferation, angiogenesis, and cell death, the non-invasive assessment of tumor microcirculation and tissue water diffusion, together with strategies for imaging the mechanisms of cellular injury and repair is of particular interest. Characterizing the tumor microenvironment prior to and in response to irradiation will help to optimize the outcome of radiotherapy. These novel concepts of personalized multi-modal cancer therapy require careful pre-treatment stratification as well as a timely and efficient therapy monitoring to maximize patient benefit on an individual basis. Functional and molecular imaging techniques are key in this regard to open novel opportunities for exploring and understanding the underlying mechanisms with the perspective to optimize therapeutic concepts and translate them into a personalized form of radiotherapy in the near future

  7. MR imaging for diagnostic evaluation of encephalopathy in the newborn.

    Science.gov (United States)

    Shroff, Manohar M; Soares-Fernandes, João P; Whyte, Hilary; Raybaud, Charles

    2010-05-01

    Magnetic resonance (MR) imaging is used with increasing frequency to evaluate the neonatal brain because it can provide important diagnostic and prognostic information that is needed for optimal treatment and appropriate counseling. Special care must be taken in preparing encephalopathic neonates for an MR study, transporting them from the intensive care unit, monitoring their vital signs, and optimizing MR sequences and protocols. Moreover, to accurately interpret the findings, specific knowledge is needed about the normal MR imaging appearances of the physiologic processes of myelination, cell migration, and sulcation, as well as patterns of injury, in the neonatal brain at various stages of gestational development. Hypoxic-ischemic injury, the most common cause of neonatal encephalopathy, has characteristic appearances that depend on the severity and duration of the insult as well as the stage of brain development. Diffusion-weighted MR imaging and MR spectroscopy depict abnormalities earlier than do conventional MR imaging sequences. However, diffusion-weighted imaging, if performed in the first 24 hours after the insult, might lead to underestimation of the extent of injury. When the MR findings are atypical, the differential diagnosis of neonatal encephalopathy also should include congenital and metabolic disorders and infectious diseases. Despite recent advances in the MR imaging-based characterization of these conditions, the clinical history must be borne in mind to achieve an accurate diagnosis.

  8. Modern imaging techniques in patients with multiple myeloma; Moderne Bildgebungsverfahren beim Multiplen Myelom

    Energy Technology Data Exchange (ETDEWEB)

    Bannas, Peter; Adam, G.; Derlin, T. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kroeger, N. [Universitaetsklinikum Hamburg-Eppendorf, Hamburg (Germany). Klinik und Poliklinik fuer Stammzelltransplantation

    2013-01-15

    Imaging studies are essential for both diagnosis and initial staging of multiple myeloma, as well as for differentiation from other monoclonal plasma cell diseases. Apart from conventional radiography, a variety of newer imaging modalities including whole-body low-dose-CT, whole-body MRI and 18F-FDG PET/CT may be used for detection of osseous and extraosseous myeloma manifestations. Despite of known limitations such as limited sensitivity and specificity and the inability to detect extraosseous lesions, conventional radiography still remains the gold standard for staging newly diagnosed myeloma, partly due to its wide availability and low costs. Whole-body low-dose CT is increasingly used due to its higher sensitivity for the detection of osseous lesions and its ability to diagnose extraosseous lesions, and is replacing conventional radiography at selected centres. The highest sensitivity for both detection of bone marrow disease and extraosseous lesions can be achieved with whole-body MRI or 18F-FDG PET/CT. Diffuse bone marrow infiltration may be visualized by whole-body MRI with high sensitivity. Whole-body MRI is at least recommended in all patients with normal conventional radiography and in all patients with an apparently solitary plasmacytoma of bone. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of myeloma lesions are required. (orig.)

  9. Computer-aided assessment of diagnostic images for epidemiological research

    Directory of Open Access Journals (Sweden)

    Gange Stephen J

    2009-11-01

    Full Text Available Abstract Background Diagnostic images are often assessed for clinical outcomes using subjective methods, which are limited by the skill of the reviewer. Computer-aided diagnosis (CAD algorithms that assist reviewers in their decisions concerning outcomes have been developed to increase sensitivity and specificity in the clinical setting. However, these systems have not been well utilized in research settings to improve the measurement of clinical endpoints. Reductions in bias through their use could have important implications for etiologic research. Methods Using the example of cortical cataract detection, we developed an algorithm for assisting a reviewer in evaluating digital images for the presence and severity of lesions. Available image processing and statistical methods that were easily implementable were used as the basis for the CAD algorithm. The performance of the system was compared to the subjective assessment of five reviewers using 60 simulated images. Cortical cataract severity scores from 0 to 16 were assigned to the images by the reviewers and the CAD system, with each image assessed twice to obtain a measure of variability. Image characteristics that affected reviewer bias were also assessed by systematically varying the appearance of the simulated images. Results The algorithm yielded severity scores with smaller bias on images where cataract severity was mild to moderate (approximately ≤ 6/16ths. On high severity images, the bias of the CAD system exceeded that of the reviewers. The variability of the CAD system was zero on repeated images but ranged from 0.48 to 1.22 for the reviewers. The direction and magnitude of the bias exhibited by the reviewers was a function of the number of cataract opacities, the shape and the contrast of the lesions in the simulated images. Conclusion CAD systems are feasible to implement with available software and can be valuable when medical images contain exposure or outcome information for

  10. Diagnostic imaging in oncology: New challenges and changing strategies

    International Nuclear Information System (INIS)

    Castellino, Ronald A.; Schwartz, Lawrence H.

    1997-01-01

    Diagnostic radiology and nuclear medicine studies, both imaging and therapeutic, play important roles in screening, staging, monitoring of treatment, and in long term surveillance of oncologic patients. Frequently, information from these studies, as well as from ancillary data (such as the clinical examination and laboratory studies) overlap, and it is sometimes unclear which tests and examinations to perform. Current changes in the delivery and funding of health care are prompting all specialties to evaluate their patterns of care. Some of the important questions to be addressed in medical imaging include: Which studies are pertinent at initial staging, e.g., those that impact patient management, serve as important baselines for comparison with subsequent studies, etc? How sensitive and specific are these studies, e.g., when can they obviate the need for more invasive confirmatory exams? What are the critical questions in monitoring response to therapy, e.g., the significance of the 'post treatment residual mass' and ways to elucidate its etiology? Which tests should be performed in surveillance for disease relapse, and how frequently should they be done? Purpose/Objective: To develop a set of guidelines for developing rational approaches for utilizing diagnostic imaging studies

  11. Diagnostic imaging in oncology: New challenges and changing strategies

    International Nuclear Information System (INIS)

    Castellino, Ronald; Schwartz, Lawrence H.

    1996-01-01

    Purpose/Objective: To develop a set of guidelines for developing rational approaches for utilizing diagnostic imaging studies. Diagnostic radiology and nuclear medicine studies, both imaging and therapeutic, play important roles in screening, staging, monitoring of treatment, and in long term surveillance of oncologic patients. Frequently, information from these studies, as well as from ancillary data (such as the clinical examination and laboratory studies) overlap, and it is sometimes unclear which tests and examinations to perform. Current changes in the delivery and funding of health care are prompting all specialties to evaluate their patterns of care. Some of the important questions to be addressed in medical imaging include: Which studies are pertinent at initial staging, e.g., those that impact patient management, serve as important baselines for comparison with subsequent studies, etc? How sensitive and specific are these studies, e.g., when can they obviate the need for more invasive confirmatory exams? What are the critical questions in monitoring response to therapy, e.g., the significance of the 'post treatment residual mass' and ways to elucidate its etiology? Which tests should be performed in surveillance for disease relapse, and how frequently should they be done?

  12. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  13. Optimum image compression rate maintaining diagnostic image quality of digital intraoral radiographs

    International Nuclear Information System (INIS)

    Song, Ju Seop; Koh, Kwang Joon

    2000-01-01

    The aims of the present study are to determine the optimum compression rate in terms of file size reduction and diagnostic quality of the images after compression and evaluate the transmission speed of original or each compressed images. The material consisted of 24 extracted human premolars and molars. The occlusal surfaces and proximal surfaces of the teeth had a clinical disease spectrum that ranged from sound to varying degrees of fissure discoloration and cavitation. The images from Digora system were exported in TIFF and the images from conventional intraoral film were scanned and digitalized in TIFF by Nikon SF-200 scanner(Nikon, Japan). And six compression factors were chosen and applied on the basis of the results from a pilot study. The total number of images to be assessed were 336. Three radiologists assessed the occlusal and proximal surfaces of the teeth with 5-rank scale. Finally diagnosed as either sound or carious lesion by one expert oral pathologist. And sensitivity and specificity and kappa value for diagnostic agreement was calculated. Also the area (Az) values under the ROC curve were calculated and paired t-test and oneway ANOVA test was performed. Thereafter, transmission time of the image files of the each compression level were compared with that of the original image files. No significant difference was found between original and the corresponding images up to 7% (1:14) compression ratio for both the occlusal and proximal caries (p<0.05). JPEG3 (1:14) image files are transmitted fast more than 10 times, maintained diagnostic information in image, compared with original image files. 1:14 compressed image file may be used instead of the original image and reduce storage needs and transmission time.

  14. Diagnostic imaging of lung cancer with In-111-MDEGD

    International Nuclear Information System (INIS)

    Nakajima, Susumu; Hayashi, Hideo; Maeda, Tomio

    1987-01-01

    Indium-111-mono DTPA-ethyleneglycol Ga deuterporphyrin (In-111-MDEGD) is a new tumor imaging agent in lung cancer. The agent has been studied with golden hamsters bearing adenocarcinoma, C57 black mice bearing Lewis lung adenocarcinoma, and nude mice bearing human lung adenocarcinoma xerografts. It has been revealed that the tumor-to-lung, tumor-to-kidney, and tumor-to-blood ratios are higher for In-111-MDEGD than for Ga-67 citrate widely used in imaging tumors, and that the agent is not accumulated in inflammatory lesions. The results were encouraging enough to start clinical diagnostic trials in lung cancer. In this paper, an overview of In-111-MDEGD, along with its preliminary data, is given. (Namekawa, K.)

  15. Advanced synchronous luminescence imaging for chemical and medical diagnostics

    Science.gov (United States)

    Vo-Dinh, Tuan

    2006-09-05

    A diagnostic method and associated system includes the steps of exposing at least one sample location with excitation radiation through a single optical waveguide or a single optical waveguide bundle, wherein the sample emits emission radiation in response to the excitation radiation. The same single optical waveguide or the single optical waveguide bundle receives at least a portion of the emission radiation from the sample, thus providing co-registration of the excitation radiation and the emission radiation. The wavelength of the excitation radiation and emission radiation is synchronously scanned to produce a spectrum upon which an image can be formed. An increased emission signal is generated by the enhanced overlap of the excitation and emission focal volumes provided by co-registration of the excitation and emission signals thus increasing the sensitivity as well as decreasing the exposure time necessary to obtain an image.

  16. Modernism as a Misnomer: Godard's Archeology of the Image

    OpenAIRE

    Gabriel Rockhill

    2010-01-01

    "The standard historical image of Jean-Luc Godard is that of a resolute iconoclast breaking with the representational norms and codes of classical cinema in the name of liberating film from the deadening weight of its past. His numerous formal innovations—syncopated montage, unconventional framing, unique experiments with dialogue, etc.—along with his abandonment of traditional narrative and character development, his playful pastiche of genres, his debunking of the representation...

  17. Assessing the value of diagnostic imaging: the role of perception

    Science.gov (United States)

    Potchen, E. J.; Cooper, Thomas G.

    2000-04-01

    The value of diagnostic radiology rests in its ability to provide information. Information is defined as a reduction in randomness. Quality improvement in any system requires diminution in the variation in its performance. The major variation in performance of the system of diagnostic radiology occurs in observer performance and in the communication of information from the observer to someone who will apply that information to the benefit of the patient. The ability to provide information can be determined by observer performance studies using a receiver-operating characteristic (ROC) curve analysis. The amount of information provided by each observer can be measured in terms of the uncertainty they reduce. Using a set of standardized radiographs, some normal and some abnormal, sorting them randomly, and then asking an observer to redistribute them according to their probability of normality can measure the difference in the value added by different observers. By applying this observer performance measure, we have been able to characterize individual radiologists, groups of radiologists, and regions of the United States in their ability to add value in chest radiology. The use of these technologies in health care may improve upon the contribution of diagnostic imaging.

  18. [The abuse of radiological diagnostic tests as a metaphor of the post-modern, new-media and consumerism society].

    Science.gov (United States)

    Dimonte, Mariano

    2008-03-01

    Aim of this paper is to offer some cue of reflection about some sociological aspects on the emergent phenomenon of the abuse of Imaging tests, interpreting this issue in the light of general dynamics crossing the actual post-modern society, so well characterized from the consumerism and the dominion of information and communication technologies, as vectors of messages mainly transmitted in a graphic format.

  19. Magnetic nanoparticles in magnetic resonance imaging and diagnostics.

    Science.gov (United States)

    Rümenapp, Christine; Gleich, Bernhard; Haase, Axel

    2012-05-01

    Magnetic nanoparticles are useful as contrast agents for magnetic resonance imaging (MRI). Paramagnetic contrast agents have been used for a long time, but more recently superparamagnetic iron oxide nanoparticles (SPIOs) have been discovered to influence MRI contrast as well. In contrast to paramagnetic contrast agents, SPIOs can be functionalized and size-tailored in order to adapt to various kinds of soft tissues. Although both types of contrast agents have a inducible magnetization, their mechanisms of influence on spin-spin and spin-lattice relaxation of protons are different. A special emphasis on the basic magnetism of nanoparticles and their structures as well as on the principle of nuclear magnetic resonance is made. Examples of different contrast-enhanced magnetic resonance images are given. The potential use of magnetic nanoparticles as diagnostic tracers is explored. Additionally, SPIOs can be used in diagnostic magnetic resonance, since the spin relaxation time of water protons differs, whether magnetic nanoparticles are bound to a target or not.

  20. Image analysis in modern ophthalmology: from acquisition to computer assisted diagnosis and telemedicine

    Science.gov (United States)

    Marrugo, Andrés G.; Millán, María S.; Cristóbal, Gabriel; Gabarda, Salvador; Sorel, Michal; Sroubek, Filip

    2012-06-01

    Medical digital imaging has become a key element of modern health care procedures. It provides visual documentation and a permanent record for the patients, and most important the ability to extract information about many diseases. Modern ophthalmology thrives and develops on the advances in digital imaging and computing power. In this work we present an overview of recent image processing techniques proposed by the authors in the area of digital eye fundus photography. Our applications range from retinal image quality assessment to image restoration via blind deconvolution and visualization of structural changes in time between patient visits. All proposed within a framework for improving and assisting the medical practice and the forthcoming scenario of the information chain in telemedicine.

  1. Diagnostic imaging of psoriatic arthritis. Part II: magnetic resonance imaging and ultrasonography

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2016-06-01

    Full Text Available Plain radiography reveals specific, yet late changes of advanced psoriatic arthritis. Early inflammatory changes are seen both on magnetic resonance imaging and ultrasound within peripheral joints (arthritis, synovitis, tendons sheaths (tenosynovitis, tendovaginitis and entheses (enthesitis, enthesopathy. In addition, magnetic resonance imaging enables the assessment of inflammatory features in the sacroiliac joints (sacroiliitis, and the spine (spondylitis. In this article, we review current opinions on the diagnostics of some selective, and distinctive features of psoriatic arthritis concerning magnetic resonance imaging and ultrasound and present some hypotheses on psoriatic arthritis etiopathogenesis, which have been studied with the use of magnetic resonance imaging. The following elements of the psoriatic arthritis are discussed: enthesitis, extracapsular inflammation, dactylitis, distal interphalangeal joint and nail disease, and the ability of magnetic resonance imaging to differentiate undifferentiated arthritis, the value of whole-body magnetic resonance imaging and dynamic contrast-enhanced magnetic resonance imaging.

  2. Inside Out: Modern Imaging Techniques to Reveal Animal Anatomy

    DEFF Research Database (Denmark)

    Lauridsen, Henrik; Hansen, Kasper; Wang, Tobias

    2011-01-01

    allow for creation of three-dimensional representations that can be of considerable value in the dissemination of anatomical studies. In this methodological review, we present our experiences using MRI, CT and mCT to create advanced representation of animal anatomy, including bones, inner organs...... and blood vessels in a variety of animals, including fish, amphibians, reptiles, mammals, and spiders. The images have a similar quality to most traditional anatomical drawings and are presented together with interactive movies of the anatomical structures, where the object can be viewed from different...

  3. Image processing methods and architectures in diagnostic pathology.

    Directory of Open Access Journals (Sweden)

    Oscar DĂŠniz

    2010-05-01

    Full Text Available Grid technology has enabled the clustering and the efficient and secure access to and interaction among a wide variety of geographically distributed resources such as: supercomputers, storage systems, data sources, instruments and special devices and services. Their main applications include large-scale computational and data intensive problems in science and engineering. General grid structures and methodologies for both software and hardware in image analysis for virtual tissue-based diagnosis has been considered in this paper. This methods are focus on the user level middleware. The article describes the distributed programming system developed by the authors for virtual slide analysis in diagnostic pathology. The system supports different image analysis operations commonly done in anatomical pathology and it takes into account secured aspects and specialized infrastructures with high level services designed to meet application requirements. Grids are likely to have a deep impact on health related applications, and therefore they seem to be suitable for tissue-based diagnosis too. The implemented system is a joint application that mixes both Web and Grid Service Architecture around a distributed architecture for image processing. It has shown to be a successful solution to analyze a big and heterogeneous group of histological images under architecture of massively parallel processors using message passing and non-shared memory.

  4. Accreditation of diagnostic imaging services in developing countries.

    Science.gov (United States)

    Jiménez, Pablo; Borrás, Cari; Fleitas, Ileana

    2006-01-01

    In recent decades, medical imaging has experienced a technological revolution. After conducting several surveys to assess the quality and safety of diagnostic imaging services in Latin America and the Caribbean, the Pan American Health Organization (PAHO) developed a basic accreditation program that can be implemented by the ministry of health of any developing country. Patterned after the American College of Radiology's accreditation program, the PAHO program relies on a national accreditation committee to establish and maintain accreditation standards. The process involves a peer review evaluation of: (1) imaging and processing equipment, (2) physician and technologist staff qualifications, (3) quality control and quality assurance programs, and (4) image quality and, where applicable, radiation dose. Public and private conventional radiography/fluoroscopy, mammography, and ultrasound services may request accreditation. The radiography/fluoroscopy accreditation program has three modules from which to choose: chest radiography, general radiography, and fluoroscopy. The national accreditation committee verifies compliance with the standards. On behalf of the ministry of health, the accreditation committee also issues a three-year accreditation certificate. As needed, the accreditation committee consults with foreign technical and clinical experts.

  5. Modern imaging techniques in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Bannas, Peter; Adam, G.; Derlin, T.; Kroeger, N.

    2013-01-01

    Imaging studies are essential for both diagnosis and initial staging of multiple myeloma, as well as for differentiation from other monoclonal plasma cell diseases. Apart from conventional radiography, a variety of newer imaging modalities including whole-body low-dose-CT, whole-body MRI and 18F-FDG PET/CT may be used for detection of osseous and extraosseous myeloma manifestations. Despite of known limitations such as limited sensitivity and specificity and the inability to detect extraosseous lesions, conventional radiography still remains the gold standard for staging newly diagnosed myeloma, partly due to its wide availability and low costs. Whole-body low-dose CT is increasingly used due to its higher sensitivity for the detection of osseous lesions and its ability to diagnose extraosseous lesions, and is replacing conventional radiography at selected centres. The highest sensitivity for both detection of bone marrow disease and extraosseous lesions can be achieved with whole-body MRI or 18F-FDG PET/CT. Diffuse bone marrow infiltration may be visualized by whole-body MRI with high sensitivity. Whole-body MRI is at least recommended in all patients with normal conventional radiography and in all patients with an apparently solitary plasmacytoma of bone. To obtain the most precise readings, optimized examination protocols and dedicated radiologists and nuclear medicine physicians familiar with the complex and variable morphologies of myeloma lesions are required. (orig.)

  6. Modern endoscopic techniques of precancerous stomach conditions diagnostics: problems and possibilities

    Directory of Open Access Journals (Sweden)

    Yu.M. Stepanov

    2017-02-01

    (in the antrum, along the small curvature of the stomach diffusely. According to the researchers’ data, the presence of the intestinal metaplasia on the lesser curvature of the stomach has a strong association with cancer risk. The different kinds of endoscopic devices allow diagnostically diffentiate atrophy and intestinal metaplasia of the stomach. Endoscopy white light can’t reliably diagnose stomach precancerous changes, while videoendoscopy with magnifications and narrow band imaging (NBI, according to researchers’ data, significantly improves the diagnosis of this disease. The basis of diagnosis is increasing verification of two main structures: the architectonic subepithelial microvascular network microstructure and mucosal surface, which has a different pattern in the body and antral stomach. But to date there is no common classification of changes to these structures in various pathological changes. There are a large number of classifications of changes in endoscopy with NBI mode and optical zoom: Yagi (2002, M. Dinis-Ribeiro (2003, G.K. Anagnostopoulos et al. (2007, T. Tahara (2009, P. Pimentel-Nunes, M. Dinis-Ribeiro (2012. It is noted that the problem is that NBI with zoom is practically impossible to use in daily clinical practice, the method requires a certain level of knowledge and endoscope type, available only in several centers, as well as the use of sedation for maximum effective inspection.

  7. Validation of Diagnostic Imaging Based on Repeat Examinations. An Image Interpretation Model

    International Nuclear Information System (INIS)

    Isberg, B.; Jorulf, H.; Thorstensen, Oe.

    2004-01-01

    Purpose: To develop an interpretation model, based on repeatedly acquired images, aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. Material and Methods: A theoretical model is proposed. The studied population consists of subjects that develop focal lesions which increase in size in organs of interest during the study period. The imaging modality produces images that can be re-interpreted with high precision, e.g. conventional radiography, computed tomography, and magnetic resonance imaging. At least four repeat examinations are carried out. Results: The interpretation is performed in four or five steps: 1. Independent readers interpret the examinations chronologically without access to previous or subsequent films. 2. Lesions found on images at the last examination are included in the analysis, with interpretation in consensus. 3. By concurrent back-reading in consensus, the lesions are identified on previous images until they are so small that even in retrospect they are undetectable. The earliest examination at which included lesions appear is recorded, and the lesions are verified by their growth (imaging reference standard). Lesion size and other characteristics may be recorded. 4. Records made at step 1 are corrected to those of steps 2 and 3. False positives are recorded. 5. (Optional) Lesion type is confirmed by another diagnostic test. Conclusion: Applied on subjects with progressive disease, the proposed image interpretation model may improve assessments of technical efficacy and diagnostic accuracy in the detection of small focal lesions. The model may provide an accurate imaging reference standard as well as repeated detection rates and false-positive rates for tested imaging modalities. However, potential review bias necessitates a strict protocol

  8. [A modern look at benign stenosing lesions. Etiology and pathogenesis of diagnostic capabilities. A systematic review].

    Science.gov (United States)

    Pakhabova, E Iu; Belova, G V

    2012-01-01

    The problem of nonneoplastic stenosis of major duodenal papilla is on joint of gastroenterology and surgery and present a challenge for physicians. This article reviews what is known about the pathogenesis, epidemiology and diagnostics of papillostenosis and sphincter of Oddi dysfunction.

  9. Modernism as a Misnomer: Godard's Archeology of the Image

    Directory of Open Access Journals (Sweden)

    Gabriel Rockhill

    2010-01-01

    Full Text Available "The standard historical image of Jean-Luc Godard is that of a resolute iconoclast breaking with the representational norms and codes of classical cinema in the name of liberating film from the deadening weight of its past. His numerous formal innovations—syncopated montage, unconventional framing, unique experiments with dialogue, etc.—along with his abandonment of traditional narrative and character development, his playful pastiche of genres, his debunking of the representational illusions of cinematic realism, his reflexive preoccupation with film itself and the general dissolution of the distinction between high and low art have created a potent new form of cinema that continues to have far-reaching effects. More experimental than Truffaut, more temerarious than Chabrol, but less fastidious than Resnais, less obtuse and prolix than Rivette, Godard is seen as the bumptious enfant terrible of the Cahiers du cinéma who set the agenda for a new era of modernist filmmaking..."

  10. Nuclear Species-Diagnostic SNP Markers Mined from 454 Amplicon Sequencing Reveal Admixture Genomic Structure of Modern Citrus Varieties

    Science.gov (United States)

    Curk, Franck; Ancillo, Gema; Ollitrault, Frédérique; Perrier, Xavier; Jacquemoud-Collet, Jean-Pierre; Garcia-Lor, Andres; Navarro, Luis; Ollitrault, Patrick

    2015-01-01

    Most cultivated Citrus species originated from interspecific hybridisation between four ancestral taxa (C. reticulata, C. maxima, C. medica, and C. micrantha) with limited further interspecific recombination due to vegetative propagation. This evolution resulted in admixture genomes with frequent interspecific heterozygosity. Moreover, a major part of the phenotypic diversity of edible citrus results from the initial differentiation between these taxa. Deciphering the phylogenomic structure of citrus germplasm is therefore essential for an efficient utilization of citrus biodiversity in breeding schemes. The objective of this work was to develop a set of species-diagnostic single nucleotide polymorphism (SNP) markers for the four Citrus ancestral taxa covering the nine chromosomes, and to use these markers to infer the phylogenomic structure of secondary species and modern cultivars. Species-diagnostic SNPs were mined from 454 amplicon sequencing of 57 gene fragments from 26 genotypes of the four basic taxa. Of the 1,053 SNPs mined from 28,507 kb sequence, 273 were found to be highly diagnostic for a single basic taxon. Species-diagnostic SNP markers (105) were used to analyse the admixture structure of varieties and rootstocks. This revealed C. maxima introgressions in most of the old and in all recent selections of mandarins, and suggested that C. reticulata × C. maxima reticulation and introgression processes were important in edible mandarin domestication. The large range of phylogenomic constitutions between C. reticulata and C. maxima revealed in mandarins, tangelos, tangors, sweet oranges, sour oranges, grapefruits, and orangelos is favourable for genetic association studies based on phylogenomic structures of the germplasm. Inferred admixture structures were in agreement with previous hypotheses regarding the origin of several secondary species and also revealed the probable origin of several acid citrus varieties. The developed species-diagnostic SNP

  11. [Future perspectives for diagnostic imaging in urology: from anatomic and functional to molecular imaging].

    Science.gov (United States)

    Macis, Giuseppe; Di Giovanni, Silvia; Di Franco, Davide; Bonomo, Lorenzo

    2013-01-01

    The future approach of diagnostic imaging in urology follows the technological progress, which made the visualization of in vivo molecular processes possible. From anatomo-morphological diagnostic imaging and through functional imaging molecular radiology is reached. Based on molecular probes, imaging is aimed at assessing the in vivo molecular processes, their physiology and function at cellular level. The future imaging will investigate the complex tumor functioning as metabolism, aerobic glycolysis in particular, angiogenesis, cell proliferation, metastatic potential, hypoxia, apoptosis and receptors expressed by neoplastic cells. Methods for performing molecular radiology are CT, MRI, PET-CT, PET-MRI, SPECT and optical imaging. Molecular ultrasound combines technological advancement with targeted contrast media based on microbubbles, this allowing the selective registration of microbubble signal while that of stationary tissues is suppressed. An experimental study was carried out where the ultrasound molecular probe BR55 strictly bound to prostate tumor results in strong enhancement in the early phase after contrast, this contrast being maintained in the late phase. This late enhancement is markedly significant for the detection of prostatic cancer foci and to guide the biopsy sampling. The 124I-cG250 molecular antibody which is strictly linked to cellular carbonic anhydrase IX of clear cell renal carcinoma, allows the acquisition of diagnostic PET images of clear cell renal carcinoma without biopsy. This WG-250 (RENCAREX) antibody was used as a therapy in metastatic clear cell renal carcinoma. Future advancements and applications will result in early cancer diagnosis, personalized therapy that will be specific according to the molecular features of cancer and leading to the development of catheter-based multichannel molecular imaging devices for cystoscopy-based molecular imaging diagnosis and intervention.

  12. Gold Nanoconstructs for Multimodal Diagnostic Imaging and Photothermal Cancer Therapy

    Science.gov (United States)

    Coughlin, Andrew James

    Cancer accounts for nearly 1 out of every 4 deaths in the United States, and because conventional treatments are limited by morbidity and off-target toxicities, improvements in cancer management are needed. This thesis further develops nanoparticle-assisted photothermal therapy (NAPT) as a viable treatment option for cancer patients. NAPT enables localized ablation of disease because heat generation only occurs where tissue permissive near-infrared (NIR) light and absorbing nanoparticles are combined, leaving surrounding normal tissue unharmed. Two principle approaches were investigated to improve the specificity of this technique: multimodal imaging and molecular targeting. Multimodal imaging affords the ability to guide NIR laser application for site-specific NAPT and more holistic characterization of disease by combining the advantages of several diagnostic technologies. Towards the goal of image-guided NAPT, gadolinium-conjugated gold-silica nanoshells were engineered and demonstrated to enhance imaging contrast across a range of diagnostic modes, including T1-weighted magnetic resonance imaging, X-Ray, optical coherence tomography, reflective confocal microscopy, and two-photon luminescence in vitro as well as within an animal tumor model. Additionally, the nanoparticle conjugates were shown to effectively convert NIR light to heat for applications in photothermal therapy. Therefore, the broad utility of gadolinium-nanoshells for anatomic localization of tissue lesions, molecular characterization of malignancy, and mediators of ablation was established. Molecular targeting strategies may also improve NAPT by promoting nanoparticle uptake and retention within tumors and enhancing specificity when malignant and normal tissue interdigitate. Here, ephrinA1 protein ligands were conjugated to nanoshell surfaces for particle homing to overexpressed EphA2 receptors on prostate cancer cells. In vitro, successful targeting and subsequent photothermal ablation of

  13. Optimization of image quality in diagnostic radiology associated with exposure

    International Nuclear Information System (INIS)

    Fulea, C.; Ramboiu, S.

    1996-01-01

    Optimal parameters for a high quality image and minimal radiation risk for the patients were established. The characteristics that affect image quality speed, contrast factor, latitude, base density, fog density, reciprocity law failure and latent image fading were analyzed. Base density on the radiographic image was measured for Azoix film and it is 0.1 log units. Fog density is a function of development time and it will increase with 20% through the increase with 2 minutes of development time. The curve Hurter-Driffield was used to characterize photographic emulsion for Azoix film. The value of latitude of 0.7 log units is in the normally useful range of densities found in radiographs. The speed of Azoix film, as a function of the time interval between exposure and development, increase with 10% for the first 24 hours. The reduction in the patient exposure that could be effected by delaying the development of Azoix is so small, that it is far outweighed by the possible disadvantage of a delay in the acquisition of diagnostic information. Therefore, latent image fading is not very important from the point of view of patient exposure. The speeds evaluated for exposure times 0.08s, 0.16s, 0.64s were unmodified, that is reciprocity law failure was unimportant for Azoix film Perlux screen. The romania films Azoix used with Perlux screen and processed with original solutions are determined an optical density of 1.0 (average density of medical radiograph) with a minimum radiation exposure for the patient (59·10 -7 C/kg). (author)

  14. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  15. Diagnostics of enterprise bankruptcy occurrence probability in an anti-crisis management: modern approaches and classification of models

    Directory of Open Access Journals (Sweden)

    I.V. Zhalinska

    2015-09-01

    Full Text Available Diagnostics of enterprise bankruptcy occurrence probability is defined as an important tool ensuring the viability of an organization under conditions of unpredictable dynamic environment. The paper aims to define the basic features of diagnostics of bankruptcy occurrence probability models and their classification. The article grounds the objective increasing of crisis probability in modern enterprises where such increasing leads to the need to improve the efficiency of anti-crisis enterprise activities. The system of anti-crisis management is based on the subsystem of diagnostics of bankruptcy occurrence probability. Such a subsystem is the main one for further measures to prevent and overcome the crisis. The classification of existing models of enterprise bankruptcy occurrence probability has been suggested. The classification is based on methodical and methodological principles of models. The following main groups of models are determined: the models using financial ratios, aggregates and scores, the models of discriminated analysis, the methods of strategic analysis, informal models, artificial intelligence systems and the combination of the models. The classification made it possible to identify the analytical capabilities of each of the groups of models suggested.

  16. Modern Theories of Pelvic Floor Support : A Topical Review of Modern Studies on Structural and Functional Pelvic Floor Support from Medical Imaging, Computational Modeling, and Electromyographic Perspectives.

    Science.gov (United States)

    Peng, Yun; Miller, Brandi D; Boone, Timothy B; Zhang, Yingchun

    2018-02-12

    Weakened pelvic floor support is believed to be the main cause of various pelvic floor disorders. Modern theories of pelvic floor support stress on the structural and functional integrity of multiple structures and their interplay to maintain normal pelvic floor functions. Connective tissues provide passive pelvic floor support while pelvic floor muscles provide active support through voluntary contraction. Advanced modern medical technologies allow us to comprehensively and thoroughly evaluate the interaction of supporting structures and assess both active and passive support functions. The pathophysiology of various pelvic floor disorders associated with pelvic floor weakness is now under scrutiny from the combination of (1) morphological, (2) dynamic (through computational modeling), and (3) neurophysiological perspectives. This topical review aims to update newly emerged studies assessing pelvic floor support function among these three categories. A literature search was performed with emphasis on (1) medical imaging studies that assess pelvic floor muscle architecture, (2) subject-specific computational modeling studies that address new topics such as modeling muscle contractions, and (3) pelvic floor neurophysiology studies that report novel devices or findings such as high-density surface electromyography techniques. We found that recent computational modeling studies are featured with more realistic soft tissue constitutive models (e.g., active muscle contraction) as well as an increasing interest in simulating surgical interventions (e.g., artificial sphincter). Diffusion tensor imaging provides a useful non-invasive tool to characterize pelvic floor muscles at the microstructural level, which can be potentially used to improve the accuracy of the simulation of muscle contraction. Studies using high-density surface electromyography anal and vaginal probes on large patient cohorts have been recently reported. Influences of vaginal delivery on the

  17. Phase contrast imaging diagnostic for the Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Boettger, Lukas-Georg; Grulke, Olaf [Max Planck Institute for Plasma Physics, 17491 Greifswald (Germany)

    2016-07-01

    The phase contrast imaging (PCI) diagnostic allows for non-invasive measurements of density fluctuations in high temperature plasmas. Since the index of refraction in a plasma is a function of the electron density, an incoming laser beam experiences a phase shift, which can be converted to intensity variations via interference after passing a phase plate. Generally speaking, the signal contains only the line-integrated information along the beam path. This limitation can be circumvented by using the fact that the density fluctuations form filamentary structures that are well aligned with the local magnetic field. If the magnetic field direction significantly varies along the beam path, optical filtering allows for localization of the density fluctuations. In order to identify the best diagnostic position regarding localization performance three figures of merit are introduced. They allow for quantitative comparison of different lines of sight and different magnetic field configurations. The results of the optimization process and a comparison with other fusion experiments are shown in this contribution.

  18. Targeting SR-BI for cancer diagnostics, imaging and therapy

    Directory of Open Access Journals (Sweden)

    Maneesha Amrita Rajora

    2016-09-01

    Full Text Available Scavenger receptor class B type I (SR-BI plays an important role in trafficking cholesteryl esters between the core of high density lipoprotein and the liver. Interestingly, this integral membrane protein receptor is also implicated in the metabolism of cholesterol by cancer cells, whereby overexpression of SR-BI has been observed in a number of tumours and cancer cell lines, including breast and prostate cancers. Consequently, SR-BI has recently gained attention as a cancer biomarker and exciting target for the direct cytosolic delivery of therapeutic agents. This brief review highlights these key developments in SR-BI-targeted cancer therapies and imaging probes. Special attention is given to the exploration of high density lipoprotein nanomimetic platforms that take advantage of upregulated SR-BI expression to facilitate targeted drug-delivery and cancer diagnostics, and promising future directions in the development of these agents.

  19. Biomedical nanotechnology for molecular imaging, diagnostics, and targeted therapy.

    Science.gov (United States)

    Nie, Shuming

    2009-01-01

    Biomedical nanotechnology is a cross-disciplinary area of research in science, engineering and medicine with broad applications for molecular imaging, molecular diagnosis, and targeted therapy. The basic rationale is that nanometer-sized particles such as semiconductor quantum dots and iron oxide nanocrystals have optical, magnetic or structural properties that are not available from either molecules or bulk solids. When linked with biotargeting ligands such as monoclonal antibodies, peptides or small molecules, these nanoparticles can be used to target diseased cells and organs (such as malignant tumors and cardiovascular plaques) with high affinity and specificity. In the "mesoscopic" size range of 5-100 nm diameter, nanoparticles also have large surface areas and functional groups for conjugating to multiple diagnostic (e.g., optical, radioisotopic, or magnetic) and therapeutic (e.g., anticancer) agents.

  20. Valuation of the paranasal sinus by means of diagnostic images

    International Nuclear Information System (INIS)

    Lozano Alfonso, Javier; Araque, Julio Mario

    1997-01-01

    The development and popularization of the surgery functional endoscopy, a bigger understanding of the anatomy and physiology of the mucociliary system of the superior airway and new techniques in diagnostics images, have allowed a better understanding of the pathology of the paranasal cavities, facilitating to make an early diagnosis and a more effective treatment. The complexity in the handling of the illnesses that affect the pearliness cavities makes obligatory that the doctors have clear concepts on the indication of each one of the modalities and the alternative in the diagnosis and pursuit of the different alterations. The paper includes topics as development and anatomy, physiology, radiology, tomography, magnetic resonance, protocol of exams and conclusions

  1. Diagnostic imaging of compression neuropathy; Bildgebende Diagnostik von Nervenkompressionssyndromen

    Energy Technology Data Exchange (ETDEWEB)

    Weishaupt, D.; Andreisek, G. [Universitaetsspital, Institut fuer Diagnostische Radiologie, Zuerich (Switzerland)

    2007-03-15

    Compression-induced neuropathy of peripheral nerves can cause severe pain of the foot and ankle. Early diagnosis is important to institute prompt treatment and to minimize potential injury. Although clinical examination combined with electrophysiological studies remain the cornerstone of the diagnostic work-up, in certain cases, imaging may provide key information with regard to the exact anatomic location of the lesion or aid in narrowing the differential diagnosis. In other patients with peripheral neuropathies of the foot and ankle, imaging may establish the etiology of the condition and provide information crucial for management and/or surgical planning. MR imaging and ultrasound provide direct visualization of the nerve and surrounding abnormalities. Bony abnormalities contributing to nerve compression are best assessed by radiographs and CT. Knowledge of the anatomy, the etiology, typical clinical findings, and imaging features of peripheral neuropathies affecting the peripheral nerves of the foot and ankle will allow for a more confident diagnosis. (orig.) [German] Kompressionsbedingte Schaedigungen peripherer Nerven koennen die Ursache hartnaeckiger Schmerzen im Bereich des Sprunggelenks und Fusses sein. Eine fruehzeitige Diagnose ist entscheidend, um den Patienten der richtigen Therapie zuzufuehren und potenzielle Schaedigungen zu vermeiden oder zu verringern. Obschon die klinische Untersuchung und die elektrophysiologische Abklaerungen die wichtigsten Elemente der Diagnostik peripherer Nervenkompressionssyndrome sind, kann die Bildgebung entscheidend sein, wenn es darum geht, die Hoehe des Nervenschadens festzulegen oder die Differenzialdiagnose einzugrenzen. In gewissen Faellen kann durch Bildgebung sogar die Ursache der Nervenkompression gefunden werden. In anderen Faellen ist die Bildgebung wichtig bei der Therapieplanung, insbesondere dann, wenn die Laesion chirurgisch angegangen wird. Magnetresonanztomographie (MRT) und Sonographie ermoeglichen eine

  2. Diagnostic imaging in child abuse; Bildgebende Diagnostik der Kindesmisshandlung

    Energy Technology Data Exchange (ETDEWEB)

    Stoever, B. [Charite, Campus Virchow-Klinikum, Universitaetsmedizin Berlin, Abteilung Paediatrische Radiologie, CC6, Diagnostische und interventionelle Radiologie und Nuklearmedizin, Berlin (Germany)

    2007-11-15

    Diagnostic imaging in child abuse plays an important role and includes the depiction of skeletal injuries, soft tissue lesions, visceral injuries in 'battered child syndrome' and brain injuries in 'shaken baby syndrome'. The use of appropriate imaging modalities allows specific fractures to be detected, skeletal lesions to be dated and the underlying mechanism of the lesion to be described. The imaging results must be taken into account when assessing the clinical history, clinical findings and differential diagnoses. Computed tomography (CT) and magnetic resonance imaging (MRI) examinations must be performed in order to detect lesions of the central nervous system (CNS) immediately. CT is necessary in the initial diagnosis to delineate oedema and haemorrhages. Early detection of brain injuries in children with severe neurological symptoms can prevent serious late sequelae. MRI is performed in follow-up investigations and is used to describe residual lesions, including parenchymal findings. (orig.) [German] In der Diagnostik der Kindesmisshandlung ist die Bildgebung ein wesentlicher Faktor. Trotz scheinbar leerer Anamnese gelingt es, typische Verletzungsmuster als Misshandlungsfolge zu erkennen, sowohl im Bereich des Skeletts, der Weichteile, des Abdomens ('battered child syndrome', heute: 'non accidental injury', NAI) als auch im ZNS ('shaken baby syndrome'). Den klinischen Symptomen entsprechend, wird im Verdachtsfall ein adaequates diagnostisches Verfahren eingesetzt, das erwartete charakteristische Befunde nachweist, den Mechanismus der Verletzung aufzeigt und das Alter der Laesionen annaehernd festlegt. Radiologische Skelettbefunde werden hinsichtlich ihrer Spezifitaet fuer eine Misshandlung bewertet. Alle Resultate der Bildgebung sind zusammen mit Anamnese und klinischen Befunden zu deuten. Bei schwerer Misshandlung ohne aeussere Verletzungszeichen ist das rechtzeitige Erfassen einer ZNS

  3. Syphilis Masquerading As Mass Lesions: The Utility of Modern-Day Imaging and Molecular Sequencing in Clinical Diagnosis.

    Science.gov (United States)

    Lin, Ray Junhao; Choudhury, Saugata; Lee, Cheng Chuan; Lee, Tau Hong

    2017-05-01

    Syphilis has been known to present in a myriad of symptoms throughout the ages, and until this day, the diagnosis remains elusive to the modern physician. We present 2 unusual cases of syphilis that posed diagnostic challenges even in the current era of new and advancing diagnostic tests.

  4. Building Modern Vibration Diagnostics Systems Based on the Frequency-Time Transformations of A Measured Signal

    Directory of Open Access Journals (Sweden)

    Yasoveev Vasikh

    2016-01-01

    Full Text Available Basic methods of analysis of vibration transducers signals were reviewed. Continuous wavelet transform, being a time-frequency transform, was found to be an advanced mathematical tool for analysis of vibration signals. Experimental studies revealed obvious changes in the continuous wavelet transform spectrum depending on the existing defects. A method for detection and identification of technological violations based on the analysis of CWT spectrum components and normalized correlation coefficient was suggested. In accordance with the suggested method software for vibration diagnostics was developed.

  5. Evolutionary and Modern Image Content Differentially Influence the Processing of Emotional Pictures

    Directory of Open Access Journals (Sweden)

    Matthias Dhum

    2017-08-01

    Full Text Available From an evolutionary perspective, environmental threats relevant for survival constantly challenged human beings. Current research suggests the evolution of a fear processing module in the brain to cope with these threats. Recently, humans increasingly encountered modern threats (e.g., guns or car accidents in addition to evolutionary threats (e.g., snakes or predators which presumably required an adaptation of perception and behavior. However, the neural processes underlying the perception of these different threats remain to be elucidated. We investigated the effect of image content (i.e., evolutionary vs. modern threats on the activation of neural networks of emotion processing. During functional magnetic resonance imaging (fMRI 41 participants watched affective pictures displaying evolutionary-threatening, modern-threatening, evolutionary-neutral and modern-neutral content. Evolutionary-threatening stimuli evoked stronger activations than modern-threatening stimuli in left inferior frontal gyrus and thalamus, right middle frontal gyrus and parietal regions as well as bilaterally in parietal regions, fusiform gyrus and bilateral amygdala. We observed the opposite effect, i.e., higher activity for modern-threatening than for evolutionary-threatening stimuli, bilaterally in the posterior cingulate and the parahippocampal gyrus. We found no differences in subjective arousal ratings between the two threatening conditions. On the valence scale though, subjects rated modern-threatening pictures significantly more negative than evolutionary-threatening pictures, indicating a higher level of perceived threat. The majority of previous studies show a positive relationship between arousal rating and amygdala activity. However, comparing fMRI results with behavioral findings we provide evidence that neural activity in fear processing areas is not only driven by arousal or valence, but presumably also by the evolutionary content of the stimulus. This has

  6. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    Science.gov (United States)

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  7. Modern molecular biomarkers of head and neck cancer. Part I. Epigenetic diagnostics and prognostics: Systematic review.

    Science.gov (United States)

    Juodzbalys, Gintaras; Kasradze, David; Cicciù, Marco; Sudeikis, Aurimas; Banys, Laurynas; Galindo-Moreno, Pablo; Guobis, Zygimantas

    2016-01-01

    Nearly half of the head and neck cancer cases are diagnosed in late stages. Traditional screening modalities have many disadvantages. The aim of the present article was to review the scientific literature about novel head and neck cancer diagnostics - epigenetic biomarkers. A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed database. Authors conducted the search of articles in English language published from 2004 to 2015. A total of thirty three relevant studies were included in the review. Fifteen of them concerned DNA methylation alterations, nine evaluation of abundancies in histone expressions and nine miRNA expression changes in HNC. Considerable number of epigenetic biomarkers have been identified in both tumor tissue and salivary samples. Genes with best diagnostic effectiveness rates and further studying prospects were: TIMP3, DCC, DAPK, CDH1, CCNA1, AIM1, MGMT, HIC1, PAX1, PAX5, ZIC4, p16, EDNRB, KIF1A, MINT31, CD44, RARβ , ECAD. Individual histone and miRNA alterations tend to be hnc specific. Prognostic values of separate biomarkers are ambiguous. No established standards for molecular assay of head and neck cancer was found in order to elude the paradoxical results and discrepancies in separate trials.

  8. Diagnostic imaging of blunt abdominal trauma in pediatric patients.

    Science.gov (United States)

    Miele, Vittorio; Piccolo, Claudia Lucia; Trinci, Margherita; Galluzzo, Michele; Ianniello, Stefania; Brunese, Luca

    2016-05-01

    Trauma is a leading cause of morbidity and mortality in childhood, and blunt trauma accounts for 80-90 % of abdominal injuries. The mechanism of trauma is quite similar to that of the adults, but there are important physiologic differences between children and adults in this field, such as the smaller blood vessels and the high vasoconstrictive response, leading to the spreading of a non-operative management. The early imaging of children undergoing a low-energy trauma can be performed by CEUS, a valuable diagnostic tool to demonstrate solid organ injuries with almost the same sensitivity of CT scans; nevertheless, as for as urinary tract injuries, MDCT remains still the technique of choice, because of its high sensitivity and accuracy, helping to discriminate between an intra-peritoneal form a retroperitoneal urinary leakage, requiring two different managements. The liver is the most common organ injured in blunt abdominal trauma followed by the spleen. Renal, pancreatic, and bowel injuries are quite rare. In this review we present various imaging findings of blunt abdominal trauma in children.

  9. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  10. PACS and diagnostic imaging service delivery-A UK perspective

    International Nuclear Information System (INIS)

    Sutton, Laurence N.

    2011-01-01

    This review sets out the current position with regard to the implementation of PACS throughout the United Kingdom and the impact this has had on improving patient care. In December 2007 England had implemented full hospital-wide PACS in all hospitals: a major achievement in the relatively short time period of three years. The different approaches used by each country of the UK to achieve full national PACS are described in addition to the current issues with the sharing of images and reports across different healthcare organisations with regard to technical solutions, clinical safety and governance. The review gives insight into the changing methods of service delivery to address increasing demand pressures on diagnostic imaging services and how the national PACS implementation, specifically in England, has made a significant contribution to measures to improve efficiencies. The role of Teleradiology is discussed in the context of supporting local patient services rather than undermining them and the concept of cross-healthcare reporting 'Grids' is described. Finally, in the summary it is recognised that the vast wealth of knowledge accumulated during the national implementations has placed the UK in a strong position to facilitate full national data sharing across all healthcare organisations to improve patient care.

  11. Modern approaches to diagnostics of combined degenerative hip and spine pathology

    Directory of Open Access Journals (Sweden)

    V. V. Khominets

    2014-01-01

    Full Text Available The results of standard radiographs of 90 patients with hip-spine syndrome associated with one unilateral or bilateral III stage hip osteoarthhrosis were analyzed with the aim to improve the diagnostics of pathological changes in the "hip joint-pelvis- spine" complex. 12 parameters of sagittal spinal-pelvic balance and 3 parameters of frontal one were studied and the degenerative changes in spinal motional segments were evaluated. The statistical processing of obtained data was made. It was stated that the most frequent variant of sagittal spinal-pelvic profile is hyperlordosic one, followed by formation of degenerative changes especially in dorsal regions of spine (р=0,076.The strategy of patient examination with hip-spine syndrome was established from clinical and radiographic positions.

  12. NONTUBERCULOUS MYCOBACTERIOSES: EPIDEMIOLOGY, CLINIC AND POSSIBILITIES OF LABORATORY DIAGNOSTICS IN MODERN CONDITIONS

    Directory of Open Access Journals (Sweden)

    Shevchenko OS

    2017-03-01

    Full Text Available Introduction. Today there are more than 150 species of nontuberculous mycobacteria (NTMB known, of which 99 were registered in Europe. Due to the similar clinical picture with tuberculosis, mycobacterioses are difficult to diagnose and often occur with TB as a mixed infection. Also, there are cases of NTMB detection in the sputum of persons previously suffered with tuberculosis, which can lead to a false diagnosis of recurrent disease. Currently, the role of atypical mycobacteria in human pathology is increasing. Atypical mycobacteria are characterized by a wide spectrum of sustainability and potential pathogenicity to humans and animals. It is generally accepted that the reservoir of infection are animals and the environment (water, soil. NTMB presence in water can lead to the erroneous diagnosis of mycobacteriosis due to laboratory contamination of samples with nontuberculous mycobacteria from the outside. Moreover recently it has been found the possibility of transferring NTMB from person to person on the background of existing lung disease. For many types of infections reservoir still has not been found. Aim of this work was to study identified in the Kharkiv region cases of non-tuberculous mycobacterioses, features of their clinical manifestations and laboratory diagnostic options. Materials and Methods. We examined 32 patients (25 men and 7 women, residents of Kharkiv and Kharkiv region, Ukraine, who were diagnosed with "non-tuberculous mycobacteriosis of lungs" during 2014-2016. Patients were examined with routine diagnostic algorithm for TB. Nontuberculous mycobacteriosis was diagnosed on the basis of NTMB growth in BACTEC system, after which the diagnosis was verified by the following criteria: 1. Smear: the absence of formation of Cord-factor (in the smear NTMB are located scattering; 2. Negative immunoassay (ID-test; 3. Negative GeneXpert MTB/RIF Then non-tuberculous mycobacteria were identificated by investigation on solid media

  13. Optimization of diagnostic imaging use in patients with acute abdominal pain (OPTIMA): Design and rationale

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Dijkgraaf, Marcel G. W.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2007-01-01

    ABSTRACT: BACKGROUND: The acute abdomen is a frequent entity at the Emergency Department (ED), which usually needs rapid and accurate diagnostic work-up. Diagnostic work-up with imaging can consist of plain X-ray, ultrasonography (US), computed tomography (CT) and even diagnostic laparoscopy.

  14. Final Report - DOE Center for Laser Imaging and Cancer Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Alfano, Robert R.; Koutcher, Jason A.

    2002-10-31

    This Final Report summarizes the significant progress made by the researchers, students and staff of the Center for Laser Imaging and Cancer Diagnostics (CLICD) from January 1998 through May 2002. During this period, the Center supported several projects. Most projects were proposed initially, some were added subsequently as their relevance and importance to the DOE mission became evident. DOE support has been leveraged to obtain continuing funding for some projects. Leveraged funds come from various sources, including NIH, Army, NSF and the Air Force. The goal of the Center was to develop laser-based instruments for use in the detection and diagnosis of major diseases, with an emphasis on detection and diagnosis of various cancers. Each of the supported projects is a collaborative effort between physicists and laser scientists and the City College of New York and noted physicians, surgeons, pathologists, and biologists located at medical centers in the Metropolitan area. The participating institutions were: City College of New York Institute for Ultrafast Lasers and Spectroscopy, Hackensack University Medical Center, Lawrence Livermore National Laboratory, Memorial Sloan Kettering Cancer Center, and New York Eye and Ear Institute. Each of the projects funded by the Center is grouped into one of four research categories: a) Disease Detection, b) Non-Disease Applications, c) New Diagnostic Tools, and, d) Education, Training, Outreach and Dissemination. The progress achieved by the multidisciplinary teams was reported in 51 publications and 32 presentations at major national conferences. Also, one U.S. patent was obtained and six U.S. patent applications have been filed for innovations resulting from the projects sponsored by the Center.

  15. Modern methods of high-pressure fuel pump common rail power system diagnostics

    Directory of Open Access Journals (Sweden)

    Kyshchun В.

    2016-08-01

    Full Text Available We've considered high pressure fuel pumps design features and equipment for their diagnosis. It was noted that the reliability of the fuel elements Common Rail system primarily provide precision parts of the fuel equipment. As a consequence, the aim of study was comparative analysis and laborious of modern methods of the high pressure fuel pump diagnosing. In particular, the definition of a technical condition of the fuel pump was carried out using a special stand and by measuring the fuel pressure and duty cycle of the pressure regulator signal. As an object of our research we've chosen Bosch № 0445010008 fuel pump (from Mercedes Benz E320cdi in which the plunger pairs were changed alternately with different technical conditions. Preliminary fuel pump parameters were determined by hydraulic testing. Based on conducted experiments we've found out that fuel pressure measurement change method and the duty cycle of the pressure regulator signal at the starting and full load modes less laborious compared to the definition of a technical condition of the pump on the stand. The results of both methods of diagnosing confirmed identity of the fuel pumps.

  16. Study design for concurrent development, assessment, and implementation of new diagnostic imaging technology

    NARCIS (Netherlands)

    M.G.M. Hunink (Myriam); G.P. Krestin (Gabriel)

    2002-01-01

    textabstractWith current constraints on health care resources and emphasis on value for money, new diagnostic imaging technologies must be assessed and their value demonstrated. The state of the art in the field of diagnostic imaging technology assessment advocates a hierarchical

  17. High Resolution Near Real Time Image Processing and Support for MSSS Modernization

    Science.gov (United States)

    Duncan, R. B.; Sabol, C.; Borelli, K.; Spetka, S.; Addison, J.; Mallo, A.; Farnsworth, B.; Viloria, R.

    2012-09-01

    This paper describes image enhancement software applications engineering development work that has been performed in support of Maui Space Surveillance System (MSSS) Modernization. It also includes R&D and transition activity that has been performed over the past few years with the objective of providing increased space situational awareness (SSA) capabilities. This includes Air Force Research Laboratory (AFRL) use of an FY10 Dedicated High Performance Investment (DHPI) cluster award -- and our selection and planned use for an FY12 DHPI award. We provide an introduction to image processing of electro optical (EO) telescope sensors data; and a high resolution image enhancement and near real time processing and summary status overview. We then describe recent image enhancement applications development and support for MSSS Modernization, results to date, and end with a discussion of desired future development work and conclusions. Significant improvements to image processing enhancement have been realized over the past several years, including a key application that has realized more than a 10,000-times speedup compared to the original R&D code -- and a greater than 72-times speedup over the past few years. The latest version of this code maintains software efficiency for post-mission processing while providing optimization for image processing of data from a new EO sensor at MSSS. Additional work has also been performed to develop low latency, near real time processing of data that is collected by the ground-based sensor during overhead passes of space objects.

  18. Hyperspectral imaging as a diagnostic tool for chronic skin ulcers

    Science.gov (United States)

    Denstedt, Martin; Pukstad, Brita S.; Paluchowski, Lukasz A.; Hernandez-Palacios, Julio E.; Randeberg, Lise L.

    2013-03-01

    The healing process of chronic wounds is complex, and the complete pathogenesis is not known. Diagnosis is currently based on visual inspection, biopsies and collection of samples from the wound surface. This is often time consuming, expensive and to some extent subjective procedures. Hyperspectral imaging has been shown to be a promising modality for optical diagnostics. The main objective of this study was to identify a suitable technique for reproducible classification of hyperspectral data from a wound and the surrounding tissue. Two statistical classification methods have been tested and compared to the performance of a dermatologist. Hyperspectral images (400-1000 nm) were collected from patients with venous leg ulcers using a pushbroom-scanning camera (VNIR 1600, Norsk Elektro Optikk AS).Wounds were examined regularly over 4 - 6 weeks. The patients were evaluated by a dermatologist at every appointment. One patient has been selected for presentation in this paper (female, age 53 years). The oxygen saturation of the wound area was determined by wavelength ratio metrics. Spectral angle mapping (SAM) and k-means clustering were used for classification. Automatic extraction of endmember spectra was employed to minimize human interaction. A comparison of the methods shows that k-means clustering is the most stable method over time, and shows the best overlap with the dermatologist's assessment of the wound border. The results are assumed to be affected by the data preprocessing and chosen endmember extraction algorithm. Results indicate that it is possible to develop an automated method for reliable classification of wounds based on hyperspectral data.

  19. Primary subacute epiphyseal osteomyelitis caused by Mycobacterium species in young children: a modern diagnostic approach.

    Science.gov (United States)

    El Houmami, N; Minodier, P; Bouvier, C; Seligmann, H; Jouve, J-L; Raoult, D; Fournier, P-E

    2017-05-01

    Primary epiphyseal subacute osteomyelitis (PESAO) caused by Mycobacterium species in young children is poorly recognized. We aimed to define the spectrum of this uncommon condition and to propose a novel diagnostic approach. We performed a systematic review of the literature on the PubMed website by selecting all reports of isolated infantile PESAO caused by Mycobacterium species since 1975. We identified 350 citations, of which 174 were assessed for eligibility based on title and abstract. The full text of 81 eligible citations was screened, and relevant data of 15 children under 4 years of age with mycobacterial PESAO were extracted. These data were pooled with those from our Institution. Data from 16 children were reviewed. The median age was 16 ± 7 months and the male:female ratio 1.7. The knee was the most common infection site (94%). The diagnosis of mycobacterial disease was delayed in all cases (range, 2 weeks to 6 months), and initially presumed by histology in 15 children (94%). Microbiologically proven diagnosis was confirmed by bone cultures in 8 of the 15 children (53%), and by specific PCR in 2 of the 3 culture-negative bone specimens (67%). Three children experienced long-term orthopedic complications despite surgical drainage and prolonged antimycobacterial regimens. All recently reported cases came from high-burden tuberculosis areas. Mycobacterium species contribute to the burden of infantile PESAO in endemic tuberculosis areas and may cause growth disturbances. We argue in favor of the early recognition of mycobacterial disease by specific molecular assays in children with infantile PESAO living in high-burden areas.

  20. Advanced imaging systems for diagnostic investigations applied to Cultural Heritage

    International Nuclear Information System (INIS)

    Peccenini, E; Bettuzzi, M; Brancaccio, R; Casali, F; Morigi, M P; Albertin, F; Petrucci, F

    2014-01-01

    The diagnostic investigations are an important resource in the studies on Cultural Heritage to enhance the knowledge on execution techniques, materials and conservation status of a work of art. In this field, due to the great historical and artistic value of the objects, preservation is the main concern; for this reason, new technological equipment has been designed and developed in the Physics Departments of the Universities of Ferrara and Bologna to enhance the non-invasive approach to the study of pictorial artworks and other objects of cultural interest. Infrared (IR) reflectography, X-ray radiography and computed tomography (CT), applied to works of art, are joined by the same goal: to get hidden information on execution techniques and inner structure pursuing the non-invasiveness of the methods, although using different setup and physical principles. In this work transportable imaging systems to investigate large objects in museums and galleries are presented. In particular, 2D scanning devices for IR reflectography and X-ray radiography, CT systems and some applications to the Cultural Heritage are described

  1. Advanced imaging systems for diagnostic investigations applied to Cultural Heritage

    Science.gov (United States)

    Peccenini, E.; Albertin, F.; Bettuzzi, M.; Brancaccio, R.; Casali, F.; Morigi, M. P.; Petrucci, F.

    2014-12-01

    The diagnostic investigations are an important resource in the studies on Cultural Heritage to enhance the knowledge on execution techniques, materials and conservation status of a work of art. In this field, due to the great historical and artistic value of the objects, preservation is the main concern; for this reason, new technological equipment has been designed and developed in the Physics Departments of the Universities of Ferrara and Bologna to enhance the non-invasive approach to the study of pictorial artworks and other objects of cultural interest. Infrared (IR) reflectography, X-ray radiography and computed tomography (CT), applied to works of art, are joined by the same goal: to get hidden information on execution techniques and inner structure pursuing the non-invasiveness of the methods, although using different setup and physical principles. In this work transportable imaging systems to investigate large objects in museums and galleries are presented. In particular, 2D scanning devices for IR reflectography and X-ray radiography, CT systems and some applications to the Cultural Heritage are described.

  2. Diagnostic imaging learning resources evaluated by students and recent graduates.

    Science.gov (United States)

    Alexander, Kate; Bélisle, Marilou; Dallaire, Sébastien; Fernandez, Nicolas; Doucet, Michèle

    2013-01-01

    Many learning resources can help students develop the problem-solving abilities and clinical skills required for diagnostic imaging. This study explored veterinary students' perceptions of the usefulness of a variety of learning resources. Perceived resource usefulness was measured for different levels of students and for academic versus clinical preparation. Third-year (n=139) and final (fifth) year (n=105) students and recent graduates (n=56) completed questionnaires on perceived usefulness of each resource. Resources were grouped for comparison: abstract/low complexity (e.g., notes, multimedia presentations), abstract/high complexity (e.g., Web-based and film case repositories), concrete/low complexity (e.g., large-group "clicker" workshops), and concrete/high complexity (e.g., small-group interpretation workshops). Lower-level students considered abstract/low-complexity resources more useful for academic preparation and concrete resources more useful for clinical preparation. Higher-level students/recent graduates also considered abstract/low-complexity resources more useful for academic preparation. For all levels, lecture notes were considered highly useful. Multimedia slideshows were an interactive complement to notes. The usefulness of a Web-based case repository was limited by accessibility problems and difficulty. Traditional abstract/low-complexity resources were considered useful for more levels and contexts than expected. Concrete/high-complexity resources need to better represent clinical practice to be considered more useful for clinical preparation.

  3. Current profile reconstruction using electron temperature imaging diagnostics

    International Nuclear Information System (INIS)

    Tritz, K.; Stutman, D.; Delgado-Aparicio, L.F.; Finkenthal, M.; Pacella, D.; Kaita, R.; Stratton, B.; Sabbagh, S.

    2004-01-01

    Flux surface shape information can be used to constrain the current profile for reconstruction of the plasma equilibrium. One method of inferring flux surface shape relies on plasma x-ray emission; however, deviations from the flux surfaces due to impurity and density asymmetries complicate the interpretation. Electron isotherm surfaces should correspond well to the plasma flux surfaces, and equilibrium constraint modeling using this isotherm information constrains the current profile. The KFIT code is used to assess the profile uncertainty and to optimize the number, location and SNR required for the Te detectors. As Te imaging detectors we consider tangentially viewing, vertically spaced, linear gas electron multiplier arrays operated in pulse height analysis (PHA) mode and multifoil soft x-ray arrays. Isoflux coordinate sets provided by T e measurements offer a strong constraint on the equilibrium reconstruction in both a stacked horizontal array configuration and a crossed horizontal and vertical beam system, with q 0 determined to within ±4%. The required SNR can be provided with either PHA or multicolor diagnostic techniques, though the multicolor system requires ∼x4 better statistics for comparable final errors

  4. Diagnostic image quality of mammograms in German outpatient medical care

    International Nuclear Information System (INIS)

    Pfandzelter, R.; Wuelfing, U.; Boedeker, B.

    2010-01-01

    Purpose: A total of 79 115 mammograms from statutory health insurance (SHI) physicians within German outpatient care were evaluated with respect to the diagnostic image quality. Materials and Methods: Mammograms were randomly selected between 2006 and 2008 by the regional Associations of Statutory Health Insurance Physicians and submitted to regional boards of experts for external evaluation. The mammogram quality was evaluated using a 3-point scale (adequate, borderline, failure) and documented using a nationally standardized protocol. Results: 87.6 % of the mammograms were classified as adequate, 11.0 % as borderline and 1.4 % as failure. Mediolateral oblique mammograms (mlo) had worse ratings than craniocaudal mammograms (cc). Main reasons for classifying the mammograms as borderline or failure were 'inframammary fold not adequately visualized' (mlo), 'pectoral muscle not in the correct angle or not to the level with the nipple' (mlo), 'the nipple not in profile' (mlo, cc) and 'breast not completely or not adequately visualized' (cc). Conclusion: The results show a good overall quality of mammograms in German outpatient medical care. Failures can be associated predominantly with incorrect positioning of the breast. More precisely defined quality criteria using objective measures are recommended, especially for craniocaudal mammograms (cc). (orig.)

  5. Contemporary diagnostic imaging approaches in treatment of urolithiasis

    International Nuclear Information System (INIS)

    Velichkov, B.; Naoumov, N.

    2004-01-01

    Based on an extensive review of the literature and on their own clinical experience, authors attempts to present clear guidelines for the management of urolithiasis. Ninety-eight per cent of stones can be successfully fragmented by the application of shock-waves, but the ability of the kidney and ureter to clear the resulting fragments is far more important in terms of successful treatment outcome. Extracorporeal shock-waves lithotripsy (ESWL) is a safe procedure for the treatment of urolithiasis; nevertheless some problems remain. In ureteric stones, ureteroscopy (rigid or flexible device) allows a rate of stone-free patients better than ESWL. For treatment of large staghorn calculi combined approach of Percutaneous Nephrolithotripsy (PCNL) and ESWL is preferred. For stones located at lower calyx, the stone-free rate in patients treated by ESWL fell to 50%, when unfavourable anatomy is present. Ultimate goal of treating stones by whatever means is to get the patient stone-free and prevent recurrence. The good technique of performing and interpretation of diagnostic imaging modalities is of critical importance in terms of diagnosing, successful treatment and follow up of results of treatment of urolithiasis

  6. X-ray imaging spectroscopic diagnostics on Nike

    Science.gov (United States)

    Aglitskiy, Y.; Karasik, M.; Serlin, V.; Weaver, J. L.; Oh, J.; Obenschain, S. P.; Ralchenko, Yu.

    2017-10-01

    Electron temperature and density diagnostics of the laser plasma produced within the focal spot of the NRL's Nike laser are being explored with the help of X-ray imaging spectroscopy. Spectra of He-like and H-like ions were taken by Nike focusing spectrometers in a range of lower (1.8 kev, Si XIV) and higher (6.7 kev, Fe XXV) x-ray energies. Data that were obtained with spatial resolution were translated into the temperature and density as functions of distance from the target. As an example electron density was determined from He-like satellites to Ly-alpha in Si XIV. The dielectronic satellites with intensity ratios that are sensitive to collisional transfer of population between different triplet groups of double-excited states 2l2l' in Si XIII were observed with high spatial and spectral resolution Lineouts taken at different axial distances from the planar Si target show changing spectral shapes due to the different electron densities as determined by supporting non-LTE simulations. These shapes are relatively insensitive to the plasma temperature which was measured using different spectral lines. This work was supported by the US DOE/NNSA.

  7. The use of X Rays in diagnostic and interventional imaging, excluding radiotherapy. Report and recommendations

    International Nuclear Information System (INIS)

    Dubousset, Jean

    2016-01-01

    The X-Ray discovery (W.C. Roentgen, 1895) offers an immediate progress to the medical efficiency. Today, the medical diagnostic imaging knows a considerable and constant growing when becoming 'interventional', as a surgical help in the operating room. These 'ionizing' radiations, simultaneously, are the first treatment for cancers (A. Beclere, 1900's). But their use in diagnostic presents a potential danger, in children and young people who are the most sensible. The medical and paramedical members of the team are dangerously exposed, too, through the accumulative exposure. Our group reminds the consequences of the ionizing radiations. Invisible, they do not create the suspicion. Therefore, the radioprotection is mandatory because of the all-lifelong cumulative dose of exposure. Many Rules and obligations, international (WHO), European (EU), and national (Agencies, HAS, Ministry of health) with the close cooperation of Societe Francaise de Radiologie (SFR) and Societe Francaise de Radioprotection (SFRP) either in radiodiagnosis or in interventional (500.000 procedures each year in France). Closely concerned by the observance of this radioprotection, the ANM had given information and texts from more than 10 years. Alas, as a pediatric orthopedist surgeon, we observe that today half of the irradiation complications (in the past from radiotherapy) went from interventional radiological procedures (and dental exercise). We went to a 30 years bibliography about this question and to a memorandum about the new indications in modern imaging and its indications with minimization of the dose delivery. We insist on the non-ionizing radiations (MRI, echography, photonic techniques). Five guidelines, concluding the text are underlined. (authors)

  8. Lesson from my dinners with the giants of modern image science

    International Nuclear Information System (INIS)

    Wagner, R. F.

    2005-01-01

    The author traces some critical moments in the history of Image Science in the last half century from first-hand or once-removed experience. The Image Science used in the field of medical imaging today had its origins in the analysis of photon detection developed for modern television, conventional photography, and the human visual system. Almost all 'model observers' used in image assessment today converge to the model originally used by Albert Rose in his analysis of those classic photo-detectors. A more general statistical analysis of the various 'defects' of conventional and unconventional photon-imaging technologies was provided by Shaw. A number of investigators in medical imaging elaborated the work of these pioneers into a synthesis with the general theory of signal detectability and extended this work to the various forms of CT, energy-spectral-dependent imaging, and the further complication of anatomical-background-noise limited imaging. The author calls for further extensions of this work to the problem of under-sampled and thus artefact-limited imaging that will be important issues for high-speed CT and MRI. (authors)

  9. Modern technologies for retinal scanning and imaging: an introduction for the biomedical engineer

    Science.gov (United States)

    2014-01-01

    This review article is meant to help biomedical engineers and nonphysical scientists better understand the principles of, and the main trends in modern scanning and imaging modalities used in ophthalmology. It is intended to ease the communication between physicists, medical doctors and engineers, and hopefully encourage “classical” biomedical engineers to generate new ideas and to initiate projects in an area which has traditionally been dominated by optical physics. Most of the methods involved are applicable to other areas of biomedical optics and optoelectronics, such as microscopic imaging, spectroscopy, spectral imaging, opto-acoustic tomography, fluorescence imaging etc., all of which are with potential biomedical application. Although all described methods are novel and important, the emphasis of this review has been placed on three technologies introduced in the 1990’s and still undergoing vigorous development: Confocal Scanning Laser Ophthalmoscopy, Optical Coherence Tomography, and polarization-sensitive retinal scanning. PMID:24779618

  10. [Diagnostic imaging of high-grade astrocytoma: heterogeneity of clinical manifestation, image characteristics, and histopathological findings].

    Science.gov (United States)

    Okajima, Kaoru; Ohta, Yoshio

    2012-10-01

    Recent developments in diagnostic radiology, which have enabled accurate differential diagnoses of brain tumors, have been well described in the last three decades. MR and PET imaging can also provide information to predict histological grades and prognoses that might influence treatment strategies. However, high-grade astrocytomas consist of many different subtypes that are associated with different imaging and histological characteristics. Hemorrhage and necrosis results in a variety of imaging features, and infiltrative tumor growth entrapping normal neurons may cause different clinical manifestations. We reviewed patients with high-grade astrocytomas that showed various imaging characteristics, with special emphasis on initial symptoms and histological features. Clinicopathological characteristics of astrocytomas were also compared with other malignant tumors. Neurological deficits were not notable in patients with grade 3-4 astrocytomas when they showed infiltrative tumor growth, while brain metastases with compact cellular proliferation caused more neurological symptoms. Infiltrative tumors did not show any enhancing masses on MR imaging, but these tumors may show intratumor heterogeneity. Seizures were reported to be more frequent in low-grade glioma and in secondary glioblastoma. Tumor heterogeneity was also reported in molecular genetic profile, and investigators identified some subsets of astrocytomas. They investigated IHD1/2 mutation, EGFR amplification, TP53 mutation, Ki-67 index, etc. In summary, high-grade astrocytomas are not homogenous groups of tumors, and this is associated with the heterogeneity of clinical manifestation, image characteristics, and histopathological findings. Molecular studies may explain the tumor heterogeneity in the near future.

  11. NMR imaging of the liver. Diagnostics, differential diagnostics, therapeutic approaches; MRT der Leber. Diagnostik, Differenzialdiagnostik, Therapieansaetze

    Energy Technology Data Exchange (ETDEWEB)

    Fischbach, Frank; Fischbach, Katharina [Universitaetsklinikum Magdeburg A.oe.R. (Germany). Klinik fuer Radiologie und Nuklearmedizin

    2017-03-01

    The book on NMR imaging of the liver covers the following issues: Fundamentals of NMR imaging, T1-weighted imaging; T2-weighted imaging, diffusion-weighted imaging, cavernous hemangioma, focal nodular hyperplasy; hepatocellular adenoma, hepatocellulas carcinoma, cholangiocellular carcinoma, hepatic metastases.

  12. From 'Image Gently' to image intelligently: a personalized perspective on diagnostic radiation risk

    International Nuclear Information System (INIS)

    Guillerman, R.P.

    2014-01-01

    The risk of ionizing radiation from diagnostic imaging has been a popular topic in the radiology literature and lay press. Communicating the magnitude of risk to patients and caregivers is problematic because of the uncertainty in estimates derived principally from epidemiological studies of large populations, and alternative approaches are needed to provide a scientific basis for personalized risk estimates. The underlying patient disease and life expectancy greatly influence risk projections. Research into the biological mechanisms of radiation-induced DNA damage and repair challenges the linear no-threshold dose-response assumption and reveals that individuals vary in sensitivity to radiation. Studies of decision-making psychology show that individuals are highly susceptible to irrational biases when judging risks. Truly informed medical decision-making that respects patient autonomy requires appropriate framing of radiation risks in perspective with other risks and with the benefits of imaging. To follow the principles of personalized medicine and treat patients according to their specific phenotypic and personality profiles, diagnostic imaging should optimally be tailored not only to patient size, body region and clinical indication, but also to underlying disease conditions, radio-sensitivity and risk perception and preferences that vary among individuals. (orig.)

  13. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.

    Science.gov (United States)

    Handels, H; Ehrhardt, J

    2009-01-01

    Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or

  14. Investigating the link between radiologists’ gaze, diagnostic decision, and image content

    Science.gov (United States)

    Tourassi, Georgia; Voisin, Sophie; Paquit, Vincent; Krupinski, Elizabeth

    2013-01-01

    Objective To investigate machine learning for linking image content, human perception, cognition, and error in the diagnostic interpretation of mammograms. Methods Gaze data and diagnostic decisions were collected from three breast imaging radiologists and three radiology residents who reviewed 20 screening mammograms while wearing a head-mounted eye-tracker. Image analysis was performed in mammographic regions that attracted radiologists’ attention and in all abnormal regions. Machine learning algorithms were investigated to develop predictive models that link: (i) image content with gaze, (ii) image content and gaze with cognition, and (iii) image content, gaze, and cognition with diagnostic error. Both group-based and individualized models were explored. Results By pooling the data from all readers, machine learning produced highly accurate predictive models linking image content, gaze, and cognition. Potential linking of those with diagnostic error was also supported to some extent. Merging readers’ gaze metrics and cognitive opinions with computer-extracted image features identified 59% of the readers’ diagnostic errors while confirming 97.3% of their correct diagnoses. The readers’ individual perceptual and cognitive behaviors could be adequately predicted by modeling the behavior of others. However, personalized tuning was in many cases beneficial for capturing more accurately individual behavior. Conclusions There is clearly an interaction between radiologists’ gaze, diagnostic decision, and image content which can be modeled with machine learning algorithms. PMID:23788627

  15. Diagnostic imaging techniques in Rubinstein-Taybi syndrome

    International Nuclear Information System (INIS)

    Albanese, A.; Carcione, A.; Benenati, A.; Albano, S.; Rubino, F.P.; Reina, C.; Verde, V.; Giuffre, L.; Corsello, G.; Cammarata, M.; Piccione, M.

    1991-01-01

    Both etiology and pathogenesis of Rubinstein-Taybi syndrome (RTS) are still questionable, even though a genetic factor seems to be certain. A typical face, psychomotor delay, and thumb and halluces abnormalities (big, prevalently short, and often 'spoon-like' toes) are the main characteristic patterns of RTS. Eight subjects (4 male and 3 female children aged 26 days-7 years, and a 31-year old woman, mother of 1 of the affected children) with different signs of RTS were studied over the last 3 years. The results are here reported, with a special emphasis on malformations detected with conventional radiography (Rx), Computerized Tomography (CT), and ultrasound (US). Evaluated parameters were thumbs and halluces (Rx), bone age and skeleton (Rx), cranium (Rx) and encephalon (US, CT), cryptochidism (US, CT), and urogical (Rx, US) and carciovascolar (US) system. Atypical face and psycomotor delay were found in all cases, while thumb and halluces abnormalities were observed only in 6 cases. Among several clinical signs of RTS, we found: severe (<3rd centile) bone maturation delay in 4 cases; skull volume reduction (<50th centile) in 3 subjects and microcrania in 4; skeletal abnormalities in 7 cases (5 of them positive for bilateral coxofemoral abnormalities); urinary tract (4 cases) and cardiovascular (3 cases) malformation; and cryptorcidism in 3 of 4 males. A case was diagnosed during neonatal period (within the first month of life) it was a rare case associated with a variant form of Dandy-Walker anomaly; semiologic similarities were observed between mother and daughter patients. X-rays, US and CT rarely play an important role in the diagnosis of RTS, considering the several clinical signs, mainly tha face, affecting the patients. However, diagnostic imaging techniques help diagnose hidden malformations and confirm and integrate clinical signs

  16. Neuro-Behcet's disease: diagnostic usefulness of MR imaging

    International Nuclear Information System (INIS)

    Kim, Song Soo; Song, Chang June; Lee, Ae Young; Pak, Chung Ho

    2000-01-01

    To suggest the characteristic MR features and to evaluate the usefulness of MR imaging for the diagnosis of neuro-Behcet's disease. We retrospectively reviewed the MR findings of clinically confirmed neuro-Behcet's disease in eight patients (M:F =3D 7:1) ranging in age from 28 to 47 (average, 36) years. The findings were analyzed in terms of the most frequently occurring sites, signal intensities, contrast enhancement, and the changing patterns seen on follow-up MR examination. Seven of the eight patients had parenchymal brain lesions and the other had dural sinus thrombosis without brain parenchymal brain abnormality. In descending order of frequency, lesions involved the pons, midbrain, medulla oblongata, internal capsule, basal ganglia, thalamus, temporal lobe, and corpus callosum. The brain stem was involved in six patients, five of whom showed extensive involvement of the entire stem. In five patients, brain stem lesions showed supratentorial involvement, and in one, involvement of this region only was noted. Signal intensities of the lesions were poorly defined and extensive, especially in the brain stem, usually showed prolongation of both T1 and T2 relaxation time. Three patients underwent follow-up examination, and this showed that while most lesions had disappeared in time, some had become small and cavitary. Initial MR examination showed that three patients had newly developed lesions as well as cavitary foci, suggesting the recurrence of disease. Contrast enhancement was noted in five of seven patients (71%), and various types, including nodular, linear, marginal, and ring. The MR features of neuro-Behcet's disease were fairly characteristic, and in clinically unsuspicious patients might be diagnostically useful. (author)

  17. Mapping the different methods adopted for diagnostic imaging instruction at medical schools in Brazil.

    Science.gov (United States)

    Chojniak, Rubens; Carneiro, Dominique Piacenti; Moterani, Gustavo Simonetto Peres; Duarte, Ivone da Silva; Bitencourt, Almir Galvão Vieira; Muglia, Valdair Francisco; D'Ippolito, Giuseppe

    2017-01-01

    To map the different methods for diagnostic imaging instruction at medical schools in Brazil. In this cross-sectional study, a questionnaire was sent to each of the coordinators of 178 Brazilian medical schools. The following characteristics were assessed: teaching model; total course hours; infrastructure; numbers of students and professionals involved; themes addressed; diagnostic imaging modalities covered; and education policies related to diagnostic imaging. Of the 178 questionnaires sent, 45 (25.3%) were completed and returned. Of those 45 responses, 17 (37.8%) were from public medical schools, whereas 28 (62.2%) were from private medical schools. Among the 45 medical schools evaluated, the method of diagnostic imaging instruction was modular at 21 (46.7%), classic (independent discipline) at 13 (28.9%), hybrid (classical and modular) at 9 (20.0%), and none of the preceding at 3 (6.7%). Diagnostic imaging is part of the formal curriculum at 36 (80.0%) of the schools, an elective course at 3 (6.7%), and included within another modality at 6 (13.3%). Professors involved in diagnostic imaging teaching are radiologists at 43 (95.5%) of the institutions. The survey showed that medical courses in Brazil tend to offer diagnostic imaging instruction in courses that include other content and at different time points during the course. Radiologists are extensively involved in undergraduate medical education, regardless of the teaching methodology employed at the institution.

  18. Requesting diagnostic imaging examinations: a position paper of the Canadian Association of Radiologists. Special article

    International Nuclear Information System (INIS)

    Stolberg, H.O.; Hynes, D.M.; Rainbow, A.J.; Moran, L.A.

    1997-01-01

    The present document is directed at physicians who request diagnostic imaging examinations. Many of the imaging examinations currently requested are not useful in managing clinical problems. The intention is to provide general guidelines for the prescription of appropriate imaging examinations. This document does not address the use of specific imaging modalities in particular clinical situations. The purpose is to help doctors make the best use of the imaging examination by providing general guidelines to assist in deciding upon the most appropriate situation in which to use the examination. Similar guidelines for the prescription of diagnostic x-ray examinations have been suggested previously. (author). 19 refs.,

  19. Diagnostic Imaging in the Medical Support of the Future Missions to the Moon

    Science.gov (United States)

    Sargsyan, Ashot E.; Jones, Jeffrey A.; Hamilton, Douglas R.; Dulchavsky, Scott A.; Duncan, J. Michael

    2007-01-01

    This viewgraph presentation is a course that reviews the diagnostic imaging techniques available for medical support on the future moon missions. The educational objectives of the course are to: 1) Update the audience on the curreultrasound imaging in space flight; 2) Discuss the unique aspects of conducting ultrasound imaging on ISS, interplanetary transit, ultrasound imaging on ISS, interplanetary transit, and lunar surface operations; and 3) Review preliminary data obtained in simulations of medical imaging in lunar surface operations.

  20. TH-A-BRF-11: Image Intensity Non-Uniformities Between MRI Simulation and Diagnostic MRI

    International Nuclear Information System (INIS)

    Paulson, E

    2014-01-01

    Purpose: MRI simulation for MRI-based radiotherapy demands that patients be setup in treatment position, which frequently involves use of alternative radiofrequency (RF) coil configurations to accommodate immobilized patients. However, alternative RF coil geometries may exacerbate image intensity non-uniformities (IINU) beyond those observed in diagnostic MRI, which may challenge image segmentation and registration accuracy as well as confound studies assessing radiotherapy response when MR simulation images are used as baselines for evaluation. The goal of this work was to determine whether differences in IINU exist between MR simulation and diagnostic MR images. Methods: ACR-MRI phantom images were acquired at 3T using a spin-echo sequence (TE/TR:20/500ms, rBW:62.5kHz, TH/skip:5/5mm). MR simulation images were obtained by wrapping two flexible phased-array RF coils around the phantom. Diagnostic MR images were obtained by placing the phantom into a commercial phased-array head coil. Pre-scan normalization was enabled in both cases. Images were transferred offline and corrected for IINU using the MNI N3 algorithm. Coefficients of variation (CV=σ/μ) were calculated for each slice. Wilcoxon matched-pairs and Mann-Whitney tests compared CV values between original and N3 images and between MR simulation and diagnostic MR images. Results: Significant differences in CV were detected between original and N3 images in both MRI simulation and diagnostic MRI groups (p=0.010, p=0.010). In addition, significant differences in CV were detected between original MR simulation and original and N3 diagnostic MR images (p=0.0256, p=0.0016). However, no significant differences in CV were detected between N3 MR simulation images and original or N3 diagnostic MR images, demonstrating the importance of correcting MR simulation images beyond pre-scan normalization prior to use in radiotherapy. Conclusions: Alternative RF coil configurations used in MRI simulation can Result in

  1. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  2. Applications of ROC analysis in diagnostic image evaluation

    International Nuclear Information System (INIS)

    Metz, C.E.

    1979-01-01

    The need for Receiver Operating Characteristic (ROC) analysis is indicated by a discussion of the limitations of accuracy and of sensitivity and specificity as indices of diagnostic detection or discrmination performance. The concept of a variable decision threshold is shown to lead in a natural way to the ROC curve as a means for specifying diagnostic performance. Practical techniques for measuring ROC curves are described, and directions for possible generalizations of conventional ROC analysis are indicated

  3. Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging

    International Nuclear Information System (INIS)

    McCarthy, C.L.; Wilson, D.J.; Coltman, T.P.

    2008-01-01

    The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in

  4. Modern radiological imaging of osteoarthritis of the hip joint with consideration of predisposing conditions

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Rehnitz, C.; Merle, C.; Gotterbarm, T.

    2016-01-01

    Osteoarthritis is the most common disease of the hip joint in adults and has a high socioeconomic impact. This review article discusses the value of three imaging modalities in the diagnosis of osteoarthritis of the hip joint: projection radiography, computed tomography, and magnetic resonance imaging (MRI). Besides established imaging diagnostics of osteoarthritis, this review also outlines new MRI techniques that enable the biochemical analysis of hip joint cartilage and discusses predisposing deformities of the hip joint including femoroacetabular impingement (FAI) with labral pathologies, hip joint dysplasia, malrotation, and, finally, femoral head necrosis, for which early detection and an exact description of the extent and localization of the necrotic area are extremely important. Conventional X-rays remain indispensable for the diagnosis of osteoarthritis, while MRI is able to depict additional early symptoms and signs of activity of the disease. With the increasing number of joint-preserving interventions such as surgical hip luxation and hip joint arthroscopy for treating FAI, high-resolution imaging is gaining further importance for both pre- and postoperative diagnostics because it can accurately recognize early stages of joint damage. With high-resolution MR sequences and MR arthrography, the detailed depiction of the thin cartilaginous coating of the hip joint has become quite possible.

  5. Investigating the Link Between Radiologists Gaze, Diagnostic Decision, and Image Content

    Energy Technology Data Exchange (ETDEWEB)

    Tourassi, Georgia [ORNL; Voisin, Sophie [ORNL; Paquit, Vincent C [ORNL; Krupinski, Elizabeth [University of Arizona

    2013-01-01

    Objective: To investigate machine learning for linking image content, human perception, cognition, and error in the diagnostic interpretation of mammograms. Methods: Gaze data and diagnostic decisions were collected from six radiologists who reviewed 20 screening mammograms while wearing a head-mounted eye-tracker. Texture analysis was performed in mammographic regions that attracted radiologists attention and in all abnormal regions. Machine learning algorithms were investigated to develop predictive models that link: (i) image content with gaze, (ii) image content and gaze with cognition, and (iii) image content, gaze, and cognition with diagnostic error. Both group-based and individualized models were explored. Results: By pooling the data from all radiologists machine learning produced highly accurate predictive models linking image content, gaze, cognition, and error. Merging radiologists gaze metrics and cognitive opinions with computer-extracted image features identified 59% of the radiologists diagnostic errors while confirming 96.2% of their correct diagnoses. The radiologists individual errors could be adequately predicted by modeling the behavior of their peers. However, personalized tuning appears to be beneficial in many cases to capture more accurately individual behavior. Conclusions: Machine learning algorithms combining image features with radiologists gaze data and diagnostic decisions can be effectively developed to recognize cognitive and perceptual errors associated with the diagnostic interpretation of mammograms.

  6. Modern clinical laboratory diagnostics

    International Nuclear Information System (INIS)

    Balakhovskij, I.S.

    1986-01-01

    Laboratory diagnosis is auxillary medical discipline studying specific laboratory symptoms of diseases, revealed by investigations of materials taken from patients. The structure of laboratory servie in our country and abroad, items of laboratory investigations, organizational principles are described. Attention is being given to the cost of analyses, the amount of conducted investigations, methods of result presentation, problems of accuracy, quality control and information content

  7. Applications of 'edge-on' illuminated porous plate detectors for diagnostic X-ray imaging

    CERN Document Server

    Shikhaliev, P M

    2002-01-01

    Scanning X-ray imaging systems for non-invasive diagnostics have several advantages over conventional imaging systems using area detectors. They significantly reduce the detected scatter radiation, cover large areas and potentially provide high spatial resolution. Applications of one-dimensional gaseous detectors and 'edge-on' illuminated silicon strip detectors for scanning imaging systems are currently under intensive investigation. The purpose of this work is to investigate 'edge-on' illuminated Porous Plate (PP) detectors for applications in diagnostic X-ray imaging. MicroChannel Plate (MCP), which is a common type of PP, has previously been investigated as a detector in surface-on illumination mode for medical X-ray imaging. However, its detection efficiency was too low for medical imaging applications. In the present study, the PP are used in the 'edge-on' illumination mode. Furthermore, the structural parameters of different PP types are optimized to improve the detection efficiency in the diagnostic X...

  8. WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

    International Nuclear Information System (INIS)

    Molloi, S; Li, B; Yin, F; Chen, H

    2014-01-01

    classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application

  9. Bladder outlet obstruction due to a small midline prostatic cyst - diagnostic imaging and interventional radiological treatment

    International Nuclear Information System (INIS)

    Hueppe, T.; Kopka, L.; Friedrich, M.; Kuehn, M.

    1992-01-01

    We describe a rare case of a bladder outlet obstruction due to a midline prostatic cyst. In the following clinical apperance, diagnostic imaging and therapy by CT-guided punction are reported. Differential diagnosis and therapy are discussed. (orig.) [de

  10. Exercise echocardiography or exercise SPECT imaging? - A meta-analysis of diagnostic test performance

    NARCIS (Netherlands)

    Fleischmann, KE; Hunink, MGM; Kuntz, KM; Douglas, PS

    1998-01-01

    Context.-Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. .-To review the contemporary literature and to compare the diagnostic performance of exercise

  11. Russian Science and Russian State: Image of a Scientist in Modern Russian Cinema

    Directory of Open Access Journals (Sweden)

    Svetlana M. Medvedeva

    2014-01-01

    Full Text Available The article analyses the image of a scientist represented in recent Russian movies. The article discusses two groups of questions: (1 nature and role of popular science in the life of society; (2 national features of scientific cultures. The article agues that popular science should not be conceived as a week copy of the real science. On the contrary, modern models of science communication assume that popular science have its own value and is able to influence scientific practices. Simultaneously we assume, that since popular science is less integrated with international scientific norms, it can easer reveal national traditions of scientific life. As a result, the analyze of recent Russian movies shows that the tradition established in Peter I times for Russian scientists to work out their self-identity in concern with Russian state still exists (scientist- state supporter/scientist- oppositionist. Actually the modern interpretation of dilemma between state patriotism and liberalism given by modern movies shows that Russian scientist don't have real choice, because they loose anyway whereas the state always wins. So owing to recent movies this representation of hopeless destiny of a scientist is becoming widespread in Russian public culture.

  12. Tree-structured vector quantization of CT chest scans: Image quality and diagnostic accuracy

    International Nuclear Information System (INIS)

    Cosman, P.C.; Tseng, C.; Gray, R.M.; Olshen, R.A.; Moses, L.E.; Davidson, H.C.; Bergin, C.J.; Riskin, E.A.

    1993-01-01

    The quality of lossy compressed images is often characterized by signal-to-noise ratios, informal tests of subjective quality, or receiver operating characteristic (ROC) curves that include subjective appraisals of the value of an image for a particular application. The authors believe that for medical applications, lossy compressed images should be judged by a more natural and fundamental aspect of relative image quality: their use in making accurate diagnoses. They apply a lossy compression algorithm to medical images, and quantify the quality of the images by the diagnostic performance of radiologists, as well as by traditional signal-to-noise ratios and subjective ratings. The study is unlike previous studies of the effects of lossy compression in that they consider non-binary detection tasks, simulate actual diagnostic practice instead of using paired tests or confidence rankings, use statistical methods that are more appropriate for non-binary clinical data than are the popular ROC curves, and use low-complexity predictive tree-structured vector quantization for compression rather than DCT-based transform codes combined with entropy coding. Their diagnostic tasks are the identification of nodules (tumors) in the lungs and lymphadenopathy in the mediastinum from computerized tomography (CT) chest scans. For the image modality, compression algorithm, and diagnostic tasks they consider, the original 12 bit per pixel (bpp) CT image can be compressed to between 1 bpp and 2 bpp with no significant changes in diagnostic accuracy

  13. Diagnostic Imaging of the Lower Respiratory Tract in Neonatal Foals: Radiography and Computed Tomography.

    Science.gov (United States)

    Lascola, Kara M; Joslyn, Stephen

    2015-12-01

    Diagnostic imaging plays an essential role in the diagnosis and monitoring of lower respiratory disease in neonatal foals. Radiography is most widely available to equine practitioners and is the primary modality that has been used for the characterization of respiratory disease in foals. Computed tomography imaging, although still limited in availability to the general practitioner, offers advantages over radiography and has been used diagnostically in neonatal foals with respiratory disease. Recognition of appropriate imaging protocols and patient-associated artifacts is critical for accurate image interpretation regardless of the modality used. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Whole Slide Images for primary diagnostics in pathology

    NARCIS (Netherlands)

    Al-Janabi, S.

    2013-01-01

    Whole slide imaging is the process of digitizing glass slides resulting in the creation of Whole Slide Images (WSI). WSI are usually explored with the aid of an image viewer in a manner that closely simulates examining glass slides with a conventional microscope, permitting the manipulation of an

  15. Radiation: Rational use of diagnostic imaging studies in pediatrics

    International Nuclear Information System (INIS)

    Gentile, Fernando

    2008-01-01

    The objectives of this paper are to recognize the biological effects of radiation; explain the action of ionizing radiation on the cell; list the main sources of ionizing radiation; to indicate imaging studies considering the danger of radiation; select the method of imaging saving radiation; rational use of imaging studies without repeating exams. [es

  16. Prostatic carcinoma. Diagnostic and stating: MR imaging. Cancer de la prostate Diagnostic et bilan: role de l'imagerie

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C; Spittler, G; Jacqmin, D [Centre Hospitalier Universitaire, 67 - Strasbourg (FR); Morel, M [Clinique Saint-Francois, 67 Haguenau (FR)

    1991-01-01

    Prostatic carcinoma is the second most commun cause of cancer death over 60 years. It is suspected by digital examination and prostatic specific antigen dosage. Transrectal ultrasound shows the tumor as an hypoechoic lesion. Sensitivity is good but specificity is low. Transrectal biopsy of prostate guided by transrectal ultrasound made the diagnosis. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging of prostatic carcinoma.

  17. Investigation of CT diagnostic imaging of 'Eosinophilic chronic rhinosinusitis'

    International Nuclear Information System (INIS)

    Ogino, Nobuhiro; Matsuwaki, Yoshinori; Ojiri, Hiroya; Kanou, Asami; Fukuda, Kunihiko

    2011-01-01

    'Eosinophilic chronic rhinosinusitis (ECRS)' is a newly developed entity of chronic rhinosinusitis, which shows resistance against conventional treatment and poor prognosis. Pathologically, ECRS is manifested by high-degree of eosinophilic infiltration in the paranasal sinus mucosa. We structure the CT diagnostic criteria of ECRS and assess its availability. This diagnostic criteria consists of disease distribution (bilateral and predominant in the ethmoid sinus), existence of nasal polyp (s) and high attenuation which suggestive of allergic mucine. We retrospectively review CT of clinically diagnosed 14 ECRS cases to see if CT features of each case fit the criteria or not. The current CT diagnostic criteria of ECRS were proven to be useful to evaluate cases with clinical suspicion of ECRS. (author)

  18. Image formation in diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Boer, J.A. den.

    1983-01-01

    This thesis deals with a physical description of the image formation in static radiographic shadow image X-ray equipment and an analysis of the optimization of such systems. For the latter criteria have been developed that take into account all relevant physical phenomena that relate to properties of the image and the radiation exposure of the patient. The discussion of image formation results in a number of relations between the X-ray system parameters on the one hand and properties of the X-ray image on the other. The three principal aspects considered are energy transfer, modulation transfer and noise. (Auth./C.F.)

  19. Megadolichobasilarartery as a rare cause of a hydrocephalus internus -synopsis of modern imaging techniques

    International Nuclear Information System (INIS)

    Lemke, A.J.; Sander, B.; Benndorf, G.; Balzer, J.; Boerschel, M.F.; Hosten, N.; Sprung, C.; Ricke, J.; Felix, R.; Lanksch, W.R.

    1995-01-01

    Megadolichobasilarartery (MDB), i.e. the widened, elongated and tortuous course of the basilar artery, has been the topic of numerous publications; about 350 cases have been reported world-wide. It can cause many symptoms; isolated or combined cranial nerve lesions and ischemic or hemorrhagic changes are the most frequent. A hydrocephalus internus is a rare occurrence and many patients do not exhibit any symptoms. To date, angiography, computed tomography, and to an increasing extent magnetic resonance imaging (MRI) are the principal methods for diagnosis of MDB. Angiographic-like representations with CT and MRI are further developments which represent an alternative to angiography. With the help of special MRI sequences, furthermore, non-invasive CSF flow measurements for the etiologic evaluation of a hydrocephalus can be performed. For the example of a patient with MDB and hydrocephalus internus, the possibilities of modern imaging techniques are presented and discussed. (orig.) [de

  20. Advanced MR diagnostic imaging in pediatric glial cell tumors: from morphological to pathophysiological evaluation

    International Nuclear Information System (INIS)

    Balev, B.; Georgiev, R.; Novakova, M.

    2013-01-01

    Full text: Introduction: The conventional MR imaging is important, and in most cases necessary imaging tool for studying the macroscopic structure, for localization and distribution of a glial brain tumor. It is an integral part of the optimal MR protocol, which further comprises a diffusion, perfusion techniques, techniques for the permeability and oxygenation assessment, as well as MR spectroscopy to the metabolism assessment. What you will learn: Glial brain tumors in children - incidence, histology, classification, diagnosis; Nature and principles of MR diffusion, perfusion, techniques for permeability and oxygenation assessment, MR spectroscopy; Contemporary techniques allowing to obtain not only MR morphological information but also to evaluate the tumor the pathophysiology: the cellular atypia, cellularity, tumor neovascularization, oxygen consumption, metabolism, status of the blood-brain barrier. This assessment determines the biological potential of the tumor, treatment options and prognosis. Discussion: The findings from conventional MR examinations, incl. administration of gadolinium contrast agents are associated with the degree of glioma and can be useful for their classification. Taking into account that from 20% to 45 % of the unenhanced supratentorial gliomas are malignant, some low-grade gliomas enhance (ganglioglioma, pilocytic astrocytoma, oligodendroglioma), 9% of malignant gliomas have no contrast enhancement, and in general, the contrast enhancement is not seen as a reliable indicator for the infiltration extent. The contemporary MR techniques improve the assessment of the pathophysiology of the tumor which is relevant to its histology and biological potential. Conclusion: Modern MR techniques besides purely diagnostic advantages (determine the extent and distribution of glioma), enable: differentiation of tumor recurrence from radiation necrosis; identification of optimal locations for biopsy or operative resection; prognosis, planning and

  1. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    International Nuclear Information System (INIS)

    Braunschweig, R.; Kaden, Ingmar; Schwarzer, J.; Sprengel, C.; Klose, K.

    2009-01-01

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  2. Image data compression in diagnostic imaging. International literature review and workflow recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Braunschweig, R.; Kaden, Ingmar [Klinik fuer Bildgebende Diagnostik und Interventionsradiologie, BG-Kliniken Bergmannstrost Halle (Germany); Schwarzer, J.; Sprengel, C. [Dept. of Management Information System and Operations Research, Martin-Luther-Univ. Halle Wittenberg (Germany); Klose, K. [Medizinisches Zentrum fuer Radiologie, Philips-Univ. Marburg (Germany)

    2009-07-15

    Purpose: Today healthcare policy is based on effectiveness. Diagnostic imaging became a ''pace-setter'' due to amazing technical developments (e.g. multislice CT), extensive data volumes, and especially the well defined workflow-orientated scenarios on a local and (inter)national level. To make centralized networks sufficient, image data compression has been regarded as the key to a simple and secure solution. In February 2008 specialized working groups of the DRG held a consensus conference. They designed recommended data compression techniques and ratios. Material und methoden: The purpose of our paper is an international review of the literature of compression technologies, different imaging procedures (e.g. DR, CT etc.), and targets (abdomen, etc.) and to combine recommendations for compression ratios and techniques with different workflows. The studies were assigned to 4 different levels (0-3) according to the evidence. 51 studies were assigned to the highest level 3. Results: We recommend a compression factor of 1: 8 (excluding cranial scans 1:5). For workflow reasons data compression should be based on the modalities (CT, etc.). PACS-based compression is currently possible but fails to maximize workflow benefits. Only the modality-based scenarios achieve all benefits. (orig.)

  3. Static dosimetry space image in which urology diagnostics are performed

    International Nuclear Information System (INIS)

    Banduka, M.S.; Vasic, D.D.

    2002-01-01

    Background. The effects of the dispersed radiation described theoretically imply complex picture of interaction of the photon beam with the patient's body, as well as its dispersion on other structures. Basic theoretical laws of this phenomenon are highlighted, thus giving the opportunity to model the effect in total. Material and methods. The measurements of the absorbed dose in the air give isodose curves that show distribution of the radiation dose. For the urological procedures standard urological diagnostic methods were being used. Results. Through a large series of measuring, we got the distribution of the radiation dose in space, where urology diagnostics is being made using the X-ray. The parameters determining this picture are the most frequent ones in the total number of 20 random cases taken in General Hospital in Doboj, Bosnia and Herzegovina. Conclusions. Static dosimetric picture of the space (radiation zone) in the general sense is useful before all for organisation of the diagnostic procedures utilising ionised radiation. Obtained in any way, this picture enables an insight into the three-dimensional distribution of the dosage on the basis of which it is possible to correct the organisation of the diagnostics being performed under these conditions. The values of the radiation dosage show it is necessary to use the protecting means prescribed by law. For more frequent exposure, it would be useful to make a dynamic dosimetric picture for professional exposure and assessment of the radiation risk of these persons. (author)

  4. Comparison of diagnostic performance for perinatal and paediatric post-mortem imaging: CT versus MRI

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Jacques, Thomas S.; Sebire, Neil J.; Guy, Anna; Chong, W.K.; Gunny, Roxanna; Saunders, Dawn; Olsen, Oystein E.; Thayyil, Sudhin; Wade, Angie; Jones, Rod; Norman, Wendy; Taylor, Andrew M.; Scott, Rosemary; Robertson, Nicola J.; Owens, Catherine M.; Offiah, Amaka C.; Chitty, Lyn S.

    2016-01-01

    To compare the diagnostic yield of whole-body post-mortem computed tomography (PMCT) imaging to post-mortem magnetic resonance (PMMR) imaging in a prospective study of fetuses and children. We compared PMCT and PMMR to conventional autopsy as the gold standard for the detection of (a) major pathological abnormalities related to the cause of death and (b) all diagnostic findings in five different body organ systems. Eighty two cases (53 fetuses and 29 children) underwent PMCT and PMMR prior to autopsy, at which 55 major abnormalities were identified. Significantly more PMCT than PMMR examinations were non-diagnostic (18/82 vs. 4/82; 21.9 % vs. 4.9 %, diff 17.1 % (95 % CI 6.7, 27.6; p < 0.05)). PMMR gave an accurate diagnosis in 24/55 (43.64 %; 95 % CI 31.37, 56.73 %) compared to 18/55 PMCT (32.73 %; 95 % CI 21.81, 45.90). PMCT was particularly poor in fetuses <24 weeks, with 28.6 % (8.1, 46.4 %) more non-diagnostic scans. Where both PMCT and PMMR were diagnostic, PMMR gave slightly higher diagnostic accuracy than PMCT (62.8 % vs. 59.4 %). Unenhanced PMCT has limited value in detection of major pathology primarily because of poor-quality, non-diagnostic fetal images. On this basis, PMMR should be the modality of choice for non-invasive PM imaging in fetuses and children. (orig.)

  5. Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

    International Nuclear Information System (INIS)

    Lee, Ji Un; Kwon, Ki Jeong; Koh, Kwang Joon

    2004-01-01

    To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities(P<0.05). The kappa value of inter-observer agreement was 0.42(range:0.28-0.60) and intra-observer agreement was 0.57(range:0.44-0.75). There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  6. Patient dosimetry and image quality in conventional diagnostic radiology. An experience from a local Serbian hospital

    International Nuclear Information System (INIS)

    Olivera Ciraj-Bjelac; Milojko Kovacevic; Dusko Kosutic; Milan Loncar; Dajana Veljkovic

    2007-01-01

    Complete test of publication follows. The optimization of image quality vs. patient dose ins an important task in medical imaging. Maximal validity of optimization has to be based on clinical images. Simultaneous measurement of patient dose levels and image quality assessment is used to investigate possibilities for dose reduction and maintain image quality. The survey was conducted in a local hospital performing more than 60000 images annually and representing typical Serbian practice. For four most frequent diagnostic procedures (seven projections) patient exposure was measured using kerma area product meter. Image quality was assessed by experienced radiologists using 'European Guidelines on Quality Criteria for Diagnostic Radiographic Images'. Following examination types were included into the survey: chest PA, chest LAT, pelvis AP, lumbar spine AP, lumbar spine LAT and LSJ, skull PA and skull LAT. Comparing actual radiographic technique with recommended technique in European Guidelines, modification of practice was proposed and implemented and image quality was re-assessed. At least 10 adult patients were followed for each projection, before and after corrective actions. Large dose saving without compromising diagnostic information were found for some examination types, showing that this simple method is very efficient dose reduction tool in conventional diagnostic radiology. Also, need for staff training and difficulties related to practical implementation of optimization methods in Serbia were discussed.

  7. Diagnostic imaging in liver transplantation. Preoperative evaluation and postoperative complications

    International Nuclear Information System (INIS)

    Schroeder, T.; Ruehm, S.G.

    2005-01-01

    Complimentary to orthotopic liver transplantation (OLT), living donor liver transplantation (LDLT) is increasingly considered a therapeutic option in the therapy of end-stage liver disease. Accurate pre- and postoperative imaging is crucial for the transplantation success and represents an established part of the current evaluation algorithms. This article summarizes the most important requirements and the current imaging standards. Preoperative imaging is important for exclusion of transplantation contraindications in the recipient and for reliable assessment of anatomical variants in the donor. The main purpose of postoperative imaging is the early detection and characterization of complications. In both instances, multislice CT currently represents the most versatile and reliable imaging modality, still superior to MRI. For postoperative follow-up, the imaging modality of first choice is still bedside ultrasound; however, unclear findings usually need to be further assessed by CT. (orig.) [de

  8. A Methodology for Anatomic Ultrasound Image Diagnostic Quality Assessment

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Lange, Theis; Brandt, Andreas Hjelm

    2017-01-01

    are presented. Earlier uses of the methodology has shown that it ensures validity of the assessment, as it separates the influences between developer, investigator, and assessor once a research protocol has been established. This separation reduces confounding influences on the result from the developer......This paper discusses methods for assessment of ultrasound image quality based on our experiences with evaluating new methods for anatomic imaging. It presents a methodology to ensure a fair assessment between competing imaging methods using clinically relevant evaluations. The methodology...... to properly reveal the clinical value. The paper exemplifies the methodology using recent studies of Synthetic Aperture Sequential Beamforming tissue harmonic imaging....

  9. Synthesis and Development of Diagnostic Tools for Medical Imaging

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Henrik

    was the synthesis of different materials. The first project introduces the development of injectable fiducial markers within the field of image-guided radiotherapy. Fiducial markers for computed tomography (CT)-imaging are today needed in order to correlate the positioning of the tumor to provide a more precise...... loading of liposomes. Long circulating contrast agents for blood pool imaging by CT-imaging are of interest due to the current limitations of short retention times and the considerable amounts needed to achieve a proper contrast. A small library of contrast agents designed for remote loading of liposomes...

  10. Intrathoracic kidney. Diagnostic value of CT scan imaging

    International Nuclear Information System (INIS)

    Baillet, A.M.; Escure, M.N.

    1988-01-01

    Two cases are reported of an ectopic right kidney that was partially intrathoracic in position. Diagnosis was simple from CT scan imaging appearances, the examination being performed to investigate an intrathoracic mass. Images showed a tissular mass within a fatty zone in sections without contrast and the typical appearance of the kidney on sections with contrast [fr

  11. Digital imaging in conventional diagnostic radiology: status and trends

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.; Schipper, P.

    1984-01-01

    Digital techniques, i.e. techniques using microcomputers of minicomputers, are getting increasingly common in so-called conventional radiography. These nonreconstructive techniques are referred to here as 'digital, direct-imaging radiography' in order to contrast them with the reconstructive techniques of computerized tomography. Digitalisation of imaging and image processing operation and control will change the jobs of the radiologist and radiological assistants in such manner that only X-ray units with film-foil systems or with X-ray image intensification should be classified as conventional systems. Digital and conventional systems differ in that digital techniques imply the possibility of establishing data pools which may eventually be developed into a digital image interconnection and archiving system. The authors first describe the general system in which the digital imaging systems must be integrated on a medium-term and long-term basis and then proceed to discuss digital imaging and image processing in some more detail. (orig./WU) [de

  12. Quality assurance in diagnostic radiology - assessing the fluoroscopic image quality

    International Nuclear Information System (INIS)

    Tabakov, S.

    1995-01-01

    The X-ray fluoroscopic image has a considerably lower resolution than the radiographic one. This requires a careful quality control aiming at optimal use of the fluoroscopic equipment. The basic procedures for image quality assessment of Image Intensifier/TV image are described. Test objects from Leeds University (UK) are used as prototypes. The results from examining 50 various fluoroscopic devices are shown. Their limiting spatial resolution varies between 0.8 lp/mm (at maximum II field size) and 2.24 lp/mm (at minimum field size). The mean value of the limiting spatial resolution for a 23 cm Image Intensifier is about 1.24 lp/mm. The mean limits of variation of the contrast/detail diagram for various fluoroscopic equipment are graphically expressed. 14 refs., 1 fig. (author)

  13. Post-graduate training in imaging diagnostics, nuclear medicine and radiotherapy for radiographers

    International Nuclear Information System (INIS)

    Petkova, E.; Velkova, K.; Shangova, M.; Karidova, S.

    2006-01-01

    Full text: The application of new technologies in imaging diagnostics, as well as the use of digital processing and storing of information, has increased the quality and scope of imaging diagnostics. The potentials of therapeutic methods connected with imaging diagnostics and nuclear medicine, interventional therapeutic procedures (dilatation, embolism, stent, etc.), basins with radio-pharmaceuticals, etc., are constantly increasing. The constant training of radiographers in working with the new, advanced image-diagnostic equipment has become an established international practice in the process of training the human resources of the imaging-diagnostic departments and centers. Objectives: 1. Investigating the potentials of post-graduate training for monitoring the dynamics in the development of the principles, methods and techniques in imaging diagnostics; 2. The attitude of radiographers towards post-graduate training. Systematic approach and critical analysis of published data and mathematical-statistical methods with regard to the need of post-graduate training. The processed data of the survey on the necessity for post-graduate training conducted among 3rd year students in the last 3 years - 75 % consider post-graduate training mandatory, 11% deem it necessary, and 14% have no opinion on the issue; and among the working radiographers in the last 3 years the results are as follows: mandatory - 91%, necessary - 7%, no opinion - 2%. The improvement and advances in imaging diagnostic equipment and apparatuses have considerably outstripped the professional training of radiographers. The key word in the race for knowledge is constant learning and training, which can successfully be achieved within the framework of post-graduate training

  14. Child abuse. Diagnostic imaging of skeletal injuries; Kindesmisshandlung. Radiologische Diagnostik skelettaler Verletzungsfolgen

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin; Mentzel, Hans-Joachim [Universitaetsklinikum Jena (Germany). Sektion Paediatrische Radiologie

    2012-06-15

    Diagnostic imaging, besides medical history and clinical examination, is a major component in assessment of cases of suspected physical child abuse. Performance of proper imaging technique, and knowledge of specific injury patterns is required for accurate image interpretation by the radiologist, and serves protection of the child in case of proven abuse. On the other side, it is essential to protect the family in unjustified accusations. The reader will be familiarised with essentials of the topic 'Physical child abuse', in order to be able to correctly assess quality, completeness, and results of X-ray films. Moreover, opportunities and limitations of alternative diagnostic modalities will be discussed. (orig.)

  15. [Dementias: diagnostic contribution of imaging and proton magnetic resonance spectroscopy].

    Science.gov (United States)

    Arana, E; Martínez-Granados, B; Marti-Bonmati, L; Martínez-Bisbal, M C; Gil, A; Blasco, C; Celda, B

    2007-06-01

    The objective is analyze the complementarity between 1H magnetic resonance spectroscopy (MRS) and magnetic resonance (MR) imaging in the global diagnosis of Alzheimer's disease (AD) or vascular dementia (VD). We studied 168 patients with cognitive impairment from AD, VD, mild cognitive impairment (MCI) and major depression. All patients were evaluated by brain MR imaging and MRS using two sample volumes localized at right medial temporal gyrus and posterior parietal gyrus. Metabolites analyzed were N-acetylaspartate (NAA), myo-Inositol (mI), Choline (Cho) and creatine (Cr), as standard references for obtaining the Co/Cr, mI/Cr and NAA/Cr ratios. Imaging and spectroscopy alterations were graded from 0 to 4 and the average of both was used to draw ROC and SROC curves. Area under ROC curve (Az) was used as a measure of discriminative ability. Combination of MR imaging and MRS significantly improved AD diagnosis (Global Az: 0.722 vs. MR imaging Az: 0.624; p: 0.003). However, the combination of MR imaging and MRS did not improve VD diagnosis. SROC curve obtained for the diagnosis of global dementia was Az: 0.6658 with 0.67 sensitivity and 0.65 specificity. Combination of both MR techniques significantly improved AD diagnosis versus MR imaging alone. More studies are needed to enhance VD classification. Metabolic data found by MRS can be useful to differentiate cognitive impairment

  16. First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

    Energy Technology Data Exchange (ETDEWEB)

    Edelen, A. L.; Biedron, S. G.; Milton, S. V.; Edelen, J. P.

    2016-12-16

    At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

  17. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  18. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  19. Effective choices for diagnostic imaging in clinical practice. Excerpts from a report of a WHO Scientific Group on Clinical Diagnostic Imaging

    International Nuclear Information System (INIS)

    1992-01-01

    There are so many different methods of diagnostic imaging that medical practitioners may need guidance to choose the best through the maze of options for each clinical problem. Advice may be required for more than just the first choice, because the first imaging procedure does not always give the desired answer and, depending on the results, further imaging may have to undertaken. The alternative is to submit the patient to a barrage of imaging and hope that one type, at least provides the diagnosis. This is a quite unacceptable way to practice medicine because of the cost and the risk of radiation damage from unnecessary examinations. The choice of the most effective imaging is often difficult and frequently controversial. The sequence to be followed vries with many factors: the equipment available, the skills of the practitioner, the expected quality of the results, the quality of interpretation, and conclusion which can be drawn

  20. Digital chest radiography: an update on modern technology, dose containment and control of image quality

    International Nuclear Information System (INIS)

    Schaefer-Prokop, Cornelia; Venema, Henk W.; Neitzel, Ulrich; Uffmann, Martin; Prokop, Mathias

    2008-01-01

    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems. (orig.)

  1. Primary ureteral carcinoma: MRI diagnosis and comparison with other diagnostic imaging facilities

    International Nuclear Information System (INIS)

    An Ningyu; Jiang Bo; Cai Youquan; Liang Yan

    2004-01-01

    Objective: To investigate MRI examination methods and imaging manifestations of primary ureteral carcinoma, and to evaluate its clinical values when comparing with other diagnostic imaging facilities. Methods: Eighty-seven cases of primary ureteral carcinoma who were operated within recent 8 years came into the study, among which, 35 cases had MRI examinations. For MRI examination, coronal heavy T 2 WI (water imaging) was performed to show the dilated ureter, then axial T 2 WI and T 1 WI were scanned at the obstruction level. 11 cases underwent additional Gd-DTPA dynamic contrast enhanced scans. The original pre-operative diagnostic reports of various imaging facilities were analyzed comparing with the results of operation and pathology. Results: MRI showed ureteral dilatation in 33 of 35 cases, no abnormal appearance in 1 case, and only primary kidney atrophy post renal transplantation in 1 case. Among the 33 cases with ureteral obstruction, soft mass at the obstruction level was detected on axial scans in 32 cases. The lesions showed gradual and homogeneous mild to moderate enhancement on contrast MRI. The overall employment rate of imaging facilities was as follows: ultrasound (94.3%), IVU (59.8%), CT (52.9%), MRI (40.2%), and RUP (35.6%). The accurate diagnostic rate was as follows :MRI (91.4%), RUP (80.6%), CT (63.0%), ultrasound (47.6%), and IVU (11.5%). Conclusion: Combination of MR water imaging and conventional sequences can demonstrate most primary ureteral carcinoma lesions and has a highest diagnostic accuracy among the current diagnostic imaging facilities. It should be taken as the first diagnostic imaging method of choice when primary ureteral carcinoma is suspected after ultrasound screening

  2. Diagnostic imaging of sport related musculoskeletal system injuries

    International Nuclear Information System (INIS)

    Fernandes, Artur da Rocha Correa; Schivartche, Vivian

    1998-01-01

    The authors review the literature about musculoskeletal injuries related to sports, emphasizing the main findings with different imaging methods. They also present the specific characteristics of each method. (author)

  3. Diagnostic imaging of injuries and overuse in soccer players

    International Nuclear Information System (INIS)

    Jonge, M.C. de; Maas, M.; Kuijk, C. van

    2002-01-01

    Soccer is one of the most popular sports worldwide. There is a high incidence of injuries in soccer in which several intrinsic and extrinsic factors play a part. Most injuries are minor, self-limiting and do not need extensive medical treatment or imaging. Imaging can be required for several reasons e.g. when the clinical findings are doubtful, to replace arthroscopy (i. e. of the knee) or for prognostic reasons. All imaging modalities available to the radiologist can be used but MRI is the most valuable imaging modality with its superior contrast resolution and multiplanar capabilities. Basically, injuries in the soccer player can occur anywhere in the body like in every sport. The lower extremities, more specific the knee and ankle, are however the most injured parts. (orig.) [de

  4. Digital image intensifier radiography: A new diagnostic procedure in traumatology?

    International Nuclear Information System (INIS)

    Schmidt, C.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1990-01-01

    Digital image intensifier radiography visualises all traumatological changes of clinical relevance and can therefore be used in traumatology. However, the quality of conventional radiographs cannot be attained as yet. Radiation exposure is markedly reduced, and radiographs are obtained directly after exposure, so that this is an extremely rapid radiographic procedure. Images can be quickly transmitted by video cable to the relevant departments and working places. (orig.) [de

  5. Chronological alterations of diagnostic imaging of renal cell carcinoma

    International Nuclear Information System (INIS)

    Arima, Kiminobu; Sugimura, Yoshiki; Yanagawa, Makoto; Tochigi, Hiromi; Kawamura, Juichi

    1994-01-01

    A review of 156 cases of renal cell carcinoma diagnosed during a 20-year period demonstrated the changes of initial signs/symptoms and imaging modalities for detection and definition. According to the imaging modality used for diagnosing renal cell carcinoma, clinical pictures were chronologically examined over 4 periods: 1973 to 1979 (before CT era), 1980 to 1984 (early CT era), 1985 to 1987 (CT era) and 1988 to 1992 (CT/MRI era). With regards to initial signs or symptoms, the proportion of classical trials has gradually decreased, while that of tumors noted incidentally has increased. As for imaging modalities for detection, the proportion of IVP has gradually decreased and that of CT and US has increased over the periods. With regard to imaging modalities for definition, the proportion of angiography has decreased and that of CT has increased. From chronological changes in clinical pictures and imaging modalities, we suggested a decision tree of imaging modalities for detection and definition of renal cell carcinoma. (author)

  6. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  7. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    DEFF Research Database (Denmark)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka

    2017-01-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identi......Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could...... be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for Me......V Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples...

  8. An image fiber based fluorescent probe with associated signal processing scheme for biomedical diagnostics

    International Nuclear Information System (INIS)

    Vaishakh, M; Murukeshan, V M; Seah, L K

    2008-01-01

    A dual-modality image fiber based fluorescent probe that can be used for depth sensitive imaging and suppression of fluorescent emissions with nanosecond lifetime difference is proposed and illustrated in this paper. The system can give high optical sectioning and employs an algorithm for obtaining phase sensitive images. The system can find main application in in vivo biomedical diagnostics for detecting biochemical changes for distinguishing malignant tissue from healthy tissue

  9. Conventional diagnostic imaging of the temporal bone. A historical review

    International Nuclear Information System (INIS)

    Canigiani, G.

    1997-01-01

    The Viennese Medical School played an important role in the development of radiological examinations and signs of the temporal bone with conventional X-rays. Famous pioneers include E.G. Mayer (1893-1969) and L. Psenner (1910-1986). Nowadays conventional X-rays and tomography have lost their important role in diagnostic radiology of the temporal bone, but the basic principles established in those early years of radiology are still used now. This statement is correct not only for conventional X-rays, but particularly for 'poly'-tomography in comparison with CT. (orig.) [de

  10. Evaluation of compression ratio using JPEG 2000 on diagnostic images in dentistry

    International Nuclear Information System (INIS)

    Jung, Gi Hun; Han, Won Jeong; Yoo, Dong Soo; Kim, Eun Kyung; Choi, Soon Chul

    2005-01-01

    To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Sixty Digora peri apical images, sixty panoramic computed radiographic (CR) images, sixty computed tomography (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent ; 2 : probably absent ; 3 : equivocal ; 4 : probably present ; 5 : definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 : definitely unacceptable ; 2 : probably unacceptable ; 3 : equivocal ; 4 : probably acceptable ; 5 : definitely acceptable), and then paired t-test was performed. In Digora, CR panoramic and CT images, compressed images up to ratios of 15:1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25:1. In Digora and CR panoramic images, compressed images up to ratios of 5:1 showed little difference between the original and reconstructed images in subjective assessment of image quality. In CT images, compressed images did up to ratios of 10:1 and in MR images up to ratios of 15:1. We considered compression ratios up to 5:1 in Digora and CR panoramic images, up to 10:1 in CT images, up to 15:1 in MR images as clinically applicable compression ratios.

  11. Is there any advantage from the hybrid imaging diagnostic?

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2012-01-01

    The hybrid imaging methods- Single Photon Emission Tomography-Computer Tomography / SPECT-CT / and Positron Emission Tomography-Computer Tomography / PET-CT/ allow receiving of combined image of two different techniques. In such a way it is possible to superimpose detailed anatomical image of the multislice spiral computer tomography with specific and sensitive molecular images of the SPECT and PET in a single study, allowing utilization of the full possibilities of the both techniques. They have advantages and disadvantages, which basically stem from the differences in the used radiopharmaceuticals and their physical properties. In PET-CT-positron emitters are applied, most often 18F and 11C, while-in SPECT-CT - single photon emitters, most often 99mTc and 131I. A disadvantage of PET is a high cost, which is produced in cyclotron and its logistics is complicated. The great advantage of PET is its better spatial resolution, compared to SPECT, because of the possibility to for simultaneous detection of pared photons and better registration. These techniques, especially PET-CT are nowadays the most increasing imaging methods in the world in making diagnosis, staging and following the effect of treatment in patients with oncological, neurological, cardiological, orthopedic diseases and infections. Recently, they are applied for the purposes of radiotherapy planning on the basis of the metabolically active tumour. As a final result, compared to the conventional techniques- roentgenography, computer tomography and magnetic resonance imaging, it is possible in many cases to make an early and more precise diagnosis and to safe time for the patient for adequate treatment. As a conclusion it is clear, that the hybrid imaging has future and its application will increase in future

  12. Diagnostic imaging in the study of human hepatobiliary fascioliasis.

    Science.gov (United States)

    Cantisani, V; Cantisani, C; Mortelé, K; Pagliara, E; D'Onofrio, M; Fernandez, M; D'Ambrosio, U; Lombardi, V; Marigliano, C; Ricci, P

    2010-02-01

    Fascioliasis is a rare zoonotic disease caused by the trematode Fasciola hepatica. We present the typical patterns of hepatobiliary fascioliasis observed in ten patients studied with multimodality imaging. Between 2002 and 2005, ten women with fascioliasis were admitted to the Brigham and Women's Hospital, Harvard Medical School (BWH), with abdominal pain and mild fever. All imaging modalities, including ultrasound (US), computed tomography (CT), magnetic resonance (MR) imaging (n = 2) and endoscopic retrograde cholangiopancreatography (ERCP) (n = 1) were reviewed by two expert radiologists working in consensus. In all patients (10/10, 100%), US showed parenchymal heterogeneity characterised by multiple subcapsular and peribiliary hypoechoic nodular lesions that were ill-defined and coalesced into tubular or tortuous structures. In six patients (6/10, 60%), the lesions appeared hypoechoic, whereas in four patients (4/10, 40%), there was an alternation of hyperechoic and hypoechoic nodules. On CT, all patients (10/10, 100%) showed hypodense patchy lesions in subcapsular, peribiliary or periportal locations, which coalesced to form tubular structures and were more evident during the portal phase. Lesion diameter ranged from 2 cm to 7 cm. Capsular enhancement was seen in four cases on CT (4/10, 40%) and in one also at MR imaging. MR imaging, performed in two patients, confirmed the presence of the lesions, which appeared hyperintense on T2-weighted images and were characterised by mild peripheral enhancement after gadolinium administration. Four patients had gallbladder wall thickening (4/10, 40%), with parasites in the gallbladder lumen. Although rare, hepatobiliary fascioliasis should be considered in the differential diagnosis in the appropriate clinical scenario, especially in patients coming from endemic areas. The typical imaging pattern of fascioliasis is the presence of subcapsular, peribiliary or periportal nodules that are usually ill-defined and coalesce

  13. Diagnostic accuracy of imaging modalities for internal derangements of temporomandibular joint

    International Nuclear Information System (INIS)

    Kobayashi, Kaoru; Igarashi, Chinami; Yuasa, Masao; Imanaka, Masahiro; Kondoh, Toshirou

    1998-01-01

    The purpose of this study was to evaluate and review the diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value of imaging diagnosis for temporomandibular disorders. The role of diagnostic imaging is to detect and document specific anatomic abnormalities associated with the signs and symptoms in the temporomandibular joint. Magnetic resonance imaging (MR imaging) can accurately depict disc displacement and disc deformity. MR imaging is our first choice among the various imaging modalities for the patients with clinical signs and symptoms. However, it has been shown that intra-capsular adhesions and perforations of the disc and retrodiscal tissue are sometimes not detected by MR imaging. To improve the diagnostic technique for adhesions and perforations, double-contrast arthrotomography with fluoroscopy should be employed. The irregular surface of the eminences and the glenoid fossae shown by MR imaging and tomography are correlated with subchondral bone exposure by arthroscopy. Erosion of the condyles detected by MR imaging, tomography and rotational panoramic radiography is correlated with subchondral bone exposure detected by arthroscopy. (author). 69 refs

  14. Breaking the chains: examining the endorsement of modern Jezebel images and racial-ethnic esteem among African American women.

    Science.gov (United States)

    Brown, Danice L; White-Johnson, Rhonda L; Griffin-Fennell, Felicia D

    2013-01-01

    The historical image of the Black Jezebel - a hypersexual, seductive and manipulative slave woman - has been one of the most pervasive and evolving images influencing the sexual socialization and perceptions of African American women today. This preliminary study examined generational differences in the endorsement of modern depictions of the Jezebel, as well as the relationship between racial-ethnic esteem and endorsement of this sexualised image. A total of 249 African American women completed an online, self-report questionnaire assessing study variables. Results suggested that younger women (aged 18-34) may exhibit higher endorsement of the modern Jezebel depictions. Additionally, aspects of racial-ethnic esteem may be linked to lower endorsement of modern Jezebel depictions among younger and older (55 years and older) African American women. Implications for future research and clinical practice are discussed.

  15. Genomics, proteomics, MEMS and SAIF: which role for diagnostic imaging?

    Science.gov (United States)

    Grassi, R; Lagalla, R; Rotondo, A

    2008-09-01

    In these three words--genomics, proteomics and nanotechnologies--is the future of medicine of the third millennium, which will be characterised by more careful attention to disease prevention, diagnosis and treatment. Molecular imaging appears to satisfy this requirement. It is emerging as a new science that brings together molecular biology and in vivo imaging and represents the key for the application of personalized medicine. Micro-PET (positron emission tomography), micro-SPECT (single photon emission computed tomography), micro-CT (computed tomography), micro-MR (magnetic resonance), micro-US (ultrasound) and optical imaging are all molecular imaging techniques, several of which are applied only in preclinical settings on animal models. Others, however, are applied routinely in both clinical and preclinical setting. Research on small animals allows investigation of the genesis and development of diseases, as well as drug efficacy and the development of personalized therapies, through the study of biological processes that precede the expression of common symptoms of a pathology. Advances in molecular imaging were made possible only by collaboration among scientists in the fields of radiology, chemistry, molecular and cell biology, physics, mathematics, pharmacology, gene therapy and oncology. Although until now researchers have traditionally limited their interactions, it is only by increasing these connections that the current gaps in terminology, methods and approaches that inhibit scientific progress can be eliminated.

  16. Doctoral theses in diagnostic imaging: a study of Spanish production between 1976 and 2011.

    Science.gov (United States)

    Machan, K; Sendra Portero, F

    2018-05-15

    To analyze the production of doctoral theses in diagnostic imaging in Spain in the period comprising 1976 through 2011 with the aim of a) determining the number of theses and their distribution over time, b) describing the production in terms of universities and directors, and c) analyzing the content of the theses according to the imaging technique, anatomic site, and type of research used. The TESEO database was searched for "radiología" and/or "diagnóstico por imagen" and for terms related to diagnostic imaging in the title of the thesis. A total of 1036 theses related to diagnostic imaging were produced in 37 Spanish universities (mean, 29.6 theses/year; range, 4-59). A total of 963 thesis directors were identified; 10 of these supervised 10 or more theses. Most candidates and directors were men, although since the 2000-2001 academic year the number of male and female candidates has been similar. The anatomic regions most often included in diagnostic imaging theses were the abdomen (22.5%), musculoskeletal system (21.8%), central nervous system (16.4%), and neck and face (15.6%). The imaging techniques most often included were ultrasonography in the entire period (25.5%) and magnetic resonance imaging in the last 5 years. Most theses (63.8%) were related to clinical research. Despite certain limitations, the TESEO database makes it possible to analyze the production of doctoral theses in Spain effectively. The annual mean production of theses in diagnostic imaging is higher than in other medical specialties. This analysis reflects the historic evolution of imaging techniques and research in radiology as well as the development of Spanish universities. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Determination of organ doses in radiographic imaging and diagnostic radiology

    International Nuclear Information System (INIS)

    Rathjen, M.

    1981-01-01

    Earlier publications on diagnostic radiation exposure commonly presented data on the gonadal dose. This emphasis on the genetic radiation risk is no longer valid in view of recent radiobiological findings; equal attention should be paid to the somatic radiation risk which is manifested by the induction of malignant neoplasms, e.g. in the lungs, red bone marrow, thyroid and female breast (ICRP 26). The permissible radiation doses for these organs and the gonals for routine diagnostic radiology are determined. A formula is established on the basis of terms from relevant publications (e.g. open-air dose, backscattering factor) and from the author's own measurements in an Alderson-Rando phantom (depth dose curves, dose decrements). The measurements were carried out using CaP 2 thermoluminescence dosemeters, and the organ doses for the various techniques of X-ray examination were calculated by computer. Calculations of this type will enable the radiologist to determine the patient exposure quickly and easily from the records kept according to Sect. 29 of the X-ray Ordinance. Experimental value from relevant publications are compared with the author's own results. (orig./HP) [de

  18. Clinics in diagnostic imaging (179). Severe rhabdomyolysis complicated by myonecrosis.

    Science.gov (United States)

    Kok, Shi Xian Shawn; Tan, Tien Jin

    2017-08-01

    A 32-year-old man presented to the emergency department with severe right lower limb pain and swelling of three days' duration. He had multiple prior admissions for recurrent seizures and suicide attempts. Markedly elevated serum creatine kinase levels and urine myoglobinuria were consistent with a diagnosis of rhabdomyolysis. Initial magnetic resonance imaging of the right lower limb revealed diffuse muscle oedema and features of myositis in the gluteal muscles and the adductor, anterior and posterior compartments of the thigh. Follow-up magnetic resonance imaging performed 11 days later showed interval development of areas of myonecrosis and haemorrhage. The causes, clinical presentation and imaging features of rhabdomyolysis are discussed. Copyright: © Singapore Medical Association.

  19. Retroperitoneal schwannoma: diagnostic imaging findings in 5 patients

    International Nuclear Information System (INIS)

    Baltazar, Alberto; Santamarina, Mario; Scalise, Gabriela; Ponce de Leon, Valeria; Bello, Lorena

    2003-01-01

    Purpose: To evaluate the different imaging findings (US, CT and MRI) in retroperitoneal schwannoma. Materials and methods: 5 patients (3 male and 2 females) with a diagnosis of retroperitoneal schwannoma were retrospectively evaluated. Ages ranged from 33 to 63 years (means 54 years). The images (US, CT and MR) were analyzed and correlated to histopathologic results. Results: The most frequent clinical finding was abdominal pain (60%). A presumptive diagnosis prior to surgery was suggested in 3/5 cases that had well-defined masses with a predominant cystic appearance. All patients underwent surgery with tumoral resection. Only 2 patients (40%) had recurrence within a three years period of follow-up. Conclusion: Retroperitoneal schwannoma is an infrequent tumor. In our series, no pathognomotic features were observed on US, CT or MRI. However, 3/5 tumors showed high signal intensity on T2-weighted images due to cystic areas. (author)

  20. Diagnostic imaging in 2001 - a health economics perspective

    International Nuclear Information System (INIS)

    Hillman, B.J.

    1997-01-01

    Factors contributing to the growth and diffusion of new imaging technologies are discussed. The benefits derived from implementing and using new technologies are carefully evaluated against the associated costs to both patients and service providers. The need to invest in early scientific assessment of a new imaging technology in order to prevent wasted aquisition and utilisation later on is highlighted. Such assessment might involve evaluating the ability of the technology to improve diagnosis, positively impact on treatment plans and, above all, improve health. (orig.)

  1. Multispectral diagnostic imaging of the iris in pigment dispersion syndrome.

    Science.gov (United States)

    Roberts, Daniel K; Lukic, Ana; Yang, Yongyi; Wilensky, Jacob T; Wernick, Miles N

    2012-08-01

    To determine if wavelength selection with near infrared iris imaging may enhance iris transillumination defects (ITDs) in pigment dispersion syndrome. An experimental apparatus was used to acquire iris images in 6 African-American (AA) and 6 White patients with pigment dispersion syndrome. Light-emitting diode probes of 6 different spectral bands (700 to 950 nm) were used to project light into patients' eyes. Iris patterns were photographed, ITD regions of interest were outlined, and region of interest contrasts were calculated for each spectral band. Contrasts varied as a function of wavelength (Ppigmented eyes may be slightly longer than for less pigmented eyes.

  2. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  3. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  4. Magnetic resonance imaging in the diagnostics of multiple sclerosis

    International Nuclear Information System (INIS)

    Larsen, J.P.; Tjoerstad, K.; Kaass, B.; Oedegaard, H.

    1987-01-01

    Multiple sclerosis is an important and frequent neurological disease and the diagnosis might be difficult. The clinical criteria of multiple sclerosis and the role of laboratory examinations in the diagnosis of the disease are discussed. In particular the help offered by the magnetic resonance imaging method is the subject of this paper. Three patients are reported and discussed

  5. Real-time image fusion involving diagnostic ultrasound

    DEFF Research Database (Denmark)

    Ewertsen, Caroline; Săftoiu, Adrian; Gruionu, Lucian G

    2013-01-01

    The aim of our article is to give an overview of the current and future possibilities of real-time image fusion involving ultrasound. We present a review of the existing English-language peer-reviewed literature assessing this technique, which covers technical solutions (for ultrasound...

  6. X-ray imaging diagnostics for the inertial confinement fusion experiments

    International Nuclear Information System (INIS)

    Aglitskiy, Y.; Lehecka, T.; Obenschain, S.; Pawley, C.; Sethian, J.; Koch, J.A.; Holland, G.

    2000-01-01

    We report on our continued development of the advanced x-ray plasma diagnostics based on spherically curved crystals. The diagnostics include x-ray spectroscopy with 1-D spatial resolution, 2-D monochromatic self-imaging and back-lighting, and can be extended to the x-ray collimating and 2-D absorption and emission spectroscopy. The system is currently used, but not limited to the diagnostics of the targets ablatively accelerated by the NRL Nike KrF laser. In cooperation with LLNL a comprehensive test of the NIF prototype spherically curved crystal assembly has been performed on the Nova laser. (authors)

  7. X-ray imaging diagnostics for the inertial confinement fusion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Aglitskiy, Y.; Lehecka, T. [Science Applications International Corp., McLean, VA (United States); Obenschain, S.; Pawley, C.; Sethian, J. [Naval Research Lab., Washington, DC (United States). Plasma Physics Div; Brown, C.M.; Seely, J. [Naval Research Lab., Space Sciences Div, Washington, DC (United States); Koch, J.A. [Lawrence Livermore National Lab., CA (United States); Holland, G. [SFA, Landover MD (United States)

    2000-07-01

    We report on our continued development of the advanced x-ray plasma diagnostics based on spherically curved crystals. The diagnostics include x-ray spectroscopy with 1-D spatial resolution, 2-D monochromatic self-imaging and back-lighting, and can be extended to the x-ray collimating and 2-D absorption and emission spectroscopy. The system is currently used, but not limited to the diagnostics of the targets ablatively accelerated by the NRL Nike KrF laser. In cooperation with LLNL a comprehensive test of the NIF prototype spherically curved crystal assembly has been performed on the Nova laser. (authors)

  8. Assessing Leg length Discrepancy Using a Biplane Low Dose Imaging System. A Comparative Diagnostic Study

    DEFF Research Database (Denmark)

    Jensen, Janni; Mussmann, Bo Redder; Torfing, Trine

    study was to evaluate the diagnostic accuracy of leg length (LL) measurements performed on low dose pre-view images acquired using a new bi-planar imaging system. The administered radiation dose from the pre-view image is approximately 20,17μGycm2 vs. 2670μGycm2 when acquiring the diagnostic image.......84) for the tibial measurements and the mean difference for total LLD was 0.01cm (p=0.92) and 0.03cm (p=0.73). All ICC calculations were >.99 indicating excellent inter- and intra-rater reliability. Conclusion. The results strongly imply that LL measurements performed on pre-view images acquired with a new bi...

  9. Diagnostic imaging of the kidney and the urinary tract in infancy

    International Nuclear Information System (INIS)

    Troeger, J.; Darge, K.; Rohrschneider, W.

    1999-01-01

    Imaging flow charts differ in pediatric and general radiology. The reasons are: Different illnesses, different consequences arising out of imaging results and different sequence of imaging methods. Ultrasound is always the first imaging method of the urinary tract in infancy and childhood starts with ultrasound with the exception of severe abdominal trauma which is investigated by computertomography. The decision 'normal or abnormal' is possible using ultrasound in the most pediatric cases. The diagnostic value and significance of ultrasound in infancy and childhood is far better than in general radiology because of the higher resolution of the high-frequency units taken. The result of the ultrasound examination should be the basis for the following imaging procedures. We will describe diagnostic flow charts starting with three important clinical symptoms: Prenatal pathology, urinary tract obstruction and urinary tract infection. (orig.) [de

  10. From Clinical Symptoms to MR Imaging: Diagnostic Steps in Adenomyosis

    Directory of Open Access Journals (Sweden)

    H. Krentel

    2017-01-01

    Full Text Available Adenomyosis or endometriosis genitalis interna is a frequent benign disease of women in fertile age. It causes symptoms like bleeding disorders and dysmenorrhea and seems to have a negative effect on fertility. Adenomyosis can be part of a complex genital and extragenital endometriosis but also can be found as a solitary uterine disease. While peritoneal endometriosis can be easily diagnosed by laparoscopy with subsequent biopsy, the determination of adenomyosis is difficult. In the following literature review, the diagnostic methods clinical history and symptoms, gynecological examination, 2D and 3D transvaginal ultrasound, MRI, hysteroscopy, and laparoscopy will be discussed step by step in order to evaluate their predictive value in the diagnosis of adenomyosis.

  11. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  12. Diagnostic imagings and embolotherapy for the superior mesenteric vein-inferior vena cava shunt

    International Nuclear Information System (INIS)

    Morita, Yutaka; Yamada, Masataka; Miyata, Mutsuhiko; Kubo, Kohzo.

    1994-01-01

    Diagnostic imaging and embolization therapy for the uncommon portal and mesenteric vein-inferior vena cave shunt (PV·SMV-IVC shunt) are reported. As the frequency of clinical symptoms such as hematemesis, melena and confusion caused by gastrointestinal varices, or hepatoencephalopathy was about 40%, it was important for this disease entity to be diagnosed with noninvasive diagnostic images. The careful examination of the area around the right renal vein was able to overcome the low diagnostic rate of 20-40% obtained with US and CT images. In cases of simple PV·SMV-IVC shut without gastrointestinal varices, embolization therapy using steel coils and done by the intravenous approach is easy and noninvasive. On the other hand, in cases of complex PV-SMV-IVC shunt with gastrointestinal varices, dual balloon occluded embolization therapy using a liquid sclerosing agent and done by the intravenous and portal approaches is preferable. (author)

  13. Three-dimensional imaging of acetabular dysplasia: diagnostic value and impact on surgical type classification

    International Nuclear Information System (INIS)

    Smet, Maria-Helena; Marchal, Guy J.; Baert, Albert L.; Hoe, Lieven van; Cleynenbreugel, Johan van; Daniels, Hans; Molenaers, Guy; Moens, Pierre; Fabry, Guy

    2000-01-01

    Objective: To investigate the diagnostic value and the impact on surgical type classification of three-dimensional (3D) images for pre-surgical evaluation of dysplastic hips. Materials and methods: Three children with a different surgical type of hip dysplasia were investigated with helical computed tomography. For each patient, two-dimensional (2D) images, 3D, and a stereolithographic model of the dysplastic hip were generated. In two separate sessions, 40 medical observers independently analyzed the 2D images (session 1), the 2D and 3D images (session 2), and tried to identify the corresponding stereolithographic hip model. The influence of both image presentation (2D versus 3D images) and observer (degree of experience, radiologist versus orthopedic surgeon) were statistically analyzed. The SL model choice reflected the impact on surgical type classification. Results: Image presentation was a significant factor whereas the individual observer was not. Three-dimensional images scored significantly better than 2D images (P=0.0003). Three-dimensional imaging increased the correct surgical type classification by 35%. Conclusion: Three-dimensional images significantly improve the pre-surgical diagnostic assessment and surgical type classification of dysplastic hips

  14. Three-dimensional imaging of acetabular dysplasia: diagnostic value and impact on surgical type classification

    Energy Technology Data Exchange (ETDEWEB)

    Smet, Maria-Helena E-mail: marleen.smet@uz.kuleuven.ac.be; Marchal, Guy J.; Baert, Albert L.; Hoe, Lieven van; Cleynenbreugel, Johan van; Daniels, Hans; Molenaers, Guy; Moens, Pierre; Fabry, Guy

    2000-04-01

    Objective: To investigate the diagnostic value and the impact on surgical type classification of three-dimensional (3D) images for pre-surgical evaluation of dysplastic hips. Materials and methods: Three children with a different surgical type of hip dysplasia were investigated with helical computed tomography. For each patient, two-dimensional (2D) images, 3D, and a stereolithographic model of the dysplastic hip were generated. In two separate sessions, 40 medical observers independently analyzed the 2D images (session 1), the 2D and 3D images (session 2), and tried to identify the corresponding stereolithographic hip model. The influence of both image presentation (2D versus 3D images) and observer (degree of experience, radiologist versus orthopedic surgeon) were statistically analyzed. The SL model choice reflected the impact on surgical type classification. Results: Image presentation was a significant factor whereas the individual observer was not. Three-dimensional images scored significantly better than 2D images (P=0.0003). Three-dimensional imaging increased the correct surgical type classification by 35%. Conclusion: Three-dimensional images significantly improve the pre-surgical diagnostic assessment and surgical type classification of dysplastic hips.

  15. Diagnostic imaging in the staging of gynecologic cancers

    International Nuclear Information System (INIS)

    Forstner, R.; Graf, A.

    1999-01-01

    The prognosis in patients with gynecologic cancers depends not only on the stage but also on a wide spectrum of other findings. Cross-sectional imaging modalities, including sonography, CT and MRI, have increasingly been used for optimal treatment planning in gynecologic cancers. Their staging criteria are based on the well-established FIGO staging system. CT and MRI compete with sonography, which plays a pivotal role in the valuation of the female pelvis. This paper reviews the role of sonography, CT and MRI in the staging of gynecologic malignancies. It puts the emphasis on MRI, which has been established as imaging modality of choice in the preoperative evaluation of cervical and endometrial cancer, and which seems slightly superior to CT in the staging of ovarian cancer. (orig.) [de

  16. Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions

    Science.gov (United States)

    Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko

    2017-09-01

    Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.

  17. Systematic application of flame diagnostics techniques for performance and emissions development of modern combustion systems; Systematischer Einsatz der Flammendiagnostik fuer die Leistungs- und Emissionsentwicklung moderner Brennverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, E.; Beidl, C.; Hirsch, A.; Piock, W. [AVL List GmbH, Graz (Austria)

    2004-07-01

    In engine engineering, the information and benefits gained from optical flame diagnostics, especially in the combination with thermodynamic and CFD analysis of airflow and combustion are well accepted. It is, however, a specific challenge to implement techniques which are well established in basic engine R and D into the processes of series development or engine calibration. Any technique taken over from successfull predevelopment applications, is expected to equally well support series development. But in order to do this, it must also be suited to easily blend into the procedures of standard multicylinder engine tests. Development speed and results quality improve consideraly, whenever engineers within their routine engine tests gain knowledge about and evaluation of flame properties which allow identification of possible improvements of combustion efficiency, power density and emissions in an early, upfront development phase. Diagnostic systems employed for such tasks make use of fiber optic sensors which in spark ignited engines may be implanted into the bodies of sensor spark plugs. Their mechanic, thermal and electric properties comply with those of the originals, thus enabling their continuous use on the test bed. The arrangement of standard fiber optic channels allows flame radiation monitoring either within the axial proximity of the sensor plug, or of the entire combustion chamber compression volume. Signal recording and signal analysis is accomplished with Visiolution system techniques. Test results are evaluated on the basis of Visiolution algorithms. Data reduction schemes provide numerical figures of merit, describing, e. g. direction, velocity and symmetry of a spark ignited flame kernel. When knock center distribution is analysed, actual distribution statistics are checked against best concept distributions, whenever diffusion flames are detected against expectations of ideal premixed flames, their position, timing and intensity is evaluated. Such

  18. Brigham and Women's Hospital handbook of diagnostic imaging

    International Nuclear Information System (INIS)

    McNeil, B.J.; Abrams, H.L.

    1985-01-01

    Basically there are 62 sections on some of the most common dilemmas dealt with. These are followed by four interesting appendixes. The clinical sections are grouped under eight headings: abdominal disease (12 sections), genito-urinary disease (seven), chest disease (seven), neurologic disease (nine), thyroid disease (one), bone disease (eight), peripheral vascular disease (one) and, finally, malignant disease (17). The four appendixes are on definitions, magnetic resonance imaging, radiation dose, and information about the range of the charges for individual studies

  19. Comparison of different phantoms used in digital diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bor, Dogan, E-mail: bor@eng.ankara.edu.tr [Ankara University, Faculty of Engineering, Department of Engineering Physics. Tandogan, 06100 Ankara (Turkey); Unal, Elif, E-mail: elf.unall@gmail.com [Radat Dosimetry Laboratory Services, 06830, Golbasi, Ankara (Turkey); Uslu, Anil, E-mail: m.aniluslu@gmail.com [Radat Dosimetry Laboratory Services, 06830, Golbasi, Ankara (Turkey)

    2015-09-21

    The organs of extremity, chest, skull and lumbar were physically simulated using uniform PMMA slabs with different thicknesses alone and using these slabs together with aluminum plates and air gaps (ANSI Phantoms). The variation of entrance surface air kerma and scatter fraction with X-ray beam qualities was investigated for these phantoms and the results were compared with those measured from anthropomorphic phantoms. A flat panel digital radiographic system was used for all the experiments. Considerable variations of entrance surface air kermas were found for the same organs of different designs, and highest doses were measured for the PMMA slabs. A low contrast test tool and a contrast detail test object (CDRAD) were used together with each organ simulation of PMMA slabs and ANSI phantoms in order to test the clinical image qualities. Digital images of these phantom combinations and anthropomorphic phantoms were acquired in raw and clinically processed formats. Variation of image quality with kVp and post processing was evaluated using the numerical metrics of these test tools and measured contrast values from the anthropomorphic phantoms. Our results indicated that design of some phantoms may not be efficient enough to reveal the expected performance of the post processing algorithms.

  20. Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis

    International Nuclear Information System (INIS)

    Zhang, Yudong; Wu, Shiliang; Xi, Zhijun; Wang, Xiaoying; Jiang, Xuexiang

    2012-01-01

    Objectives: To study whether the individual radiological findings can help predict diagnosis of pelvic lipomatosis (PL) or, specifically appreciate its progression. Methods: Data from 32 clinically proven cases of PL and 25 controls were collected. Two reviewers were recruited for a blinded evaluation, image features were recorded in terms of: (1) bladder shape; (2) bladder-rectosigmoid morphological indexes including ratio of superior–inferior to anterior–posterior length of bladder (SI/AP), angle between anterior and posterior wall (AAP), relative length of posterior urethra (rLPU), angle between bladder and seminal vesicle (ABS) and rectosigmoid morphological index (RMI); (3) secondary complications. Results were evaluated by an unpaired t test and ROC analysis. Results: The sensitivity and specificity were 40.6% and 100% for pear and banana-shaped bladder, 62.5% and 100% for SI/AP, 40.6% and 100% for AAP, 62.5% and 100% for ABS, 78.1% and 72% for rLPU, 59.4% and 96% for RMI, respectively. These radiological findings partially correlated with the severity of disease weighted by hydronephrosis and treatment grade. Image analysis demonstrated high prevalence of glandular cystitis (100%) and hydronephrosis (73.4%). Conclusion: We conclude that PL is a progressive disease involving multiple pelvic organs with high prevalence of intractable cystitis and hydronephrosis. The imaging characteristics can help predict diagnosis and, specifically appreciate progression.

  1. Measuring diagnostic accuracy of imaging parameters in pelvic lipomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yudong, E-mail: pku_zyd06@163.com [Department of Radiology, Peking University First Hospital, Beijing (China); Wu, Shiliang, E-mail: wushiliangjsh@263.net [Department of Urology, Peking University First Hospital, Beijing (China); Xi, Zhijun, E-mail: xizhijun@hsc.pku.edu.cn [Department of Urology, Peking University First Hospital, Beijing (China); Wang, Xiaoying, E-mail: cjr.wangxiaoying@vip.163.com [Department of Radiology, Peking University First Hospital, Beijing (China); Jiang, Xuexiang, E-mail: cjr.jxx@vip.163.com [Department of Radiology, Peking University First Hospital, Beijing (China)

    2012-11-15

    Objectives: To study whether the individual radiological findings can help predict diagnosis of pelvic lipomatosis (PL) or, specifically appreciate its progression. Methods: Data from 32 clinically proven cases of PL and 25 controls were collected. Two reviewers were recruited for a blinded evaluation, image features were recorded in terms of: (1) bladder shape; (2) bladder-rectosigmoid morphological indexes including ratio of superior-inferior to anterior-posterior length of bladder (SI/AP), angle between anterior and posterior wall (AAP), relative length of posterior urethra (rLPU), angle between bladder and seminal vesicle (ABS) and rectosigmoid morphological index (RMI); (3) secondary complications. Results were evaluated by an unpaired t test and ROC analysis. Results: The sensitivity and specificity were 40.6% and 100% for pear and banana-shaped bladder, 62.5% and 100% for SI/AP, 40.6% and 100% for AAP, 62.5% and 100% for ABS, 78.1% and 72% for rLPU, 59.4% and 96% for RMI, respectively. These radiological findings partially correlated with the severity of disease weighted by hydronephrosis and treatment grade. Image analysis demonstrated high prevalence of glandular cystitis (100%) and hydronephrosis (73.4%). Conclusion: We conclude that PL is a progressive disease involving multiple pelvic organs with high prevalence of intractable cystitis and hydronephrosis. The imaging characteristics can help predict diagnosis and, specifically appreciate progression.

  2. The Potential Impact of Collaborative and Three-Dimensional Imaging Technology on SHIPMAIN Fleet Modernization Plan

    National Research Council Canada - National Science Library

    Seaman, Nathan L; Housel, Thomas; Mun, Jonathan

    2008-01-01

    Maintenance and modernization of the US Navy fleet is big business. The Navy has invested substantial fiscal and human resources to standardize the processes used to accomplish maintenance modernization and repair for its fleet of ships...

  3. The clinician's guide to diagnostic imaging: Cost-effective pathways. Second edition

    International Nuclear Information System (INIS)

    Grossman, Z.D.; Chew, F.S.; Ellis, D.A.; Brigham, S.C.

    1987-01-01

    The authors developed a cost-effective approach to imaging studies, based on initial selection of an exam that best addresses the specific clinical problem and obviates the need for additional diagnostic tests. Tightly reasoned arguments compare available imaging options with respect to diagnostic yield, feasibility, risk, and cost. To aid the clinician in making cost comparisons, each paper of the Second Edition lists the dollar cost of relevant imaging studies. The Second Edition has been thoroughly revised to reflect the important advances in diagnostic imaging of the past three years, highlighting CT's expanding role in thoracic and abdominal problems, magnetic resonance imaging as a spectacular diagnostic tool for the central nervous system, and the clinical application of many newly-developed radiopharmaceuticals. New chapters cover breast cancer screening, acute spinal trauma, search for primary cancer of unknown origin, acute anuria, blunt chest trauma, new onset seizures, and spinal cord compression from metastases. Other papers have been rewritten for greater clarity and to incorporate new techniques, like dipyridamole stress testing. A glossary and an introduction define and explain the capabilities and limitations of current techniques

  4. Diagnostic imaging procedures during pregnancy: what are the fetal risks?

    International Nuclear Information System (INIS)

    Taylor, K.

    2008-01-01

    An important facet of health care is the counsel of patients seeking a better understanding of their medical treatment. One of the most challenging scenarios is the management of female patients exposed to ionizing radiation while pregnant. It requires careful consideration of both maternal benefit and fetal risk. Given the increased frequency of diagnostic examinations involving ionizing radiation, this situation has become commonplace. This paper reviews current literature discussing the risk associated with prenatal exposure to ionizing radiation. The fetal dose received during common radiological procedures is reported in order to emphasize that these doses do not exceed threshold levels for deterministic effects. The definitive cancer risk associated with radiation exposure in utero has yet to be established. This paper will also show that physicians who deal with pregnant women are generally uninformed or misinformed of the doses and risks associated with the exams that they prescribe. This lack of information could be leading to inappropriate advice and actions with respect to patient care. (author)

  5. Diagnostic imaging procedures during pregnancy: what are the fetal risks?

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K. [McMaster Univ., Hamilton, Ontario (Canada)

    2008-07-01

    An important facet of health care is the counsel of patients seeking a better understanding of their medical treatment. One of the most challenging scenarios is the management of female patients exposed to ionizing radiation while pregnant. It requires careful consideration of both maternal benefit and fetal risk. Given the increased frequency of diagnostic examinations involving ionizing radiation, this situation has become commonplace. This paper reviews current literature discussing the risk associated with prenatal exposure to ionizing radiation. The fetal dose received during common radiological procedures is reported in order to emphasize that these doses do not exceed threshold levels for deterministic effects. The definitive cancer risk associated with radiation exposure in utero has yet to be established. This paper will also show that physicians who deal with pregnant women are generally uninformed or misinformed of the doses and risks associated with the exams that they prescribe. This lack of information could be leading to inappropriate advice and actions with respect to patient care. (author)

  6. Impact of neutral density fluctuations on gas puff imaging diagnostics

    Science.gov (United States)

    Wersal, C.; Ricci, P.

    2017-11-01

    A three-dimensional turbulence simulation of the SOL and edge regions of a toroidally limited tokamak is carried out. The simulation couples self-consistently the drift-reduced two-fluid Braginskii equations to a kinetic equation for neutral atoms. A diagnostic neutral gas puff on the low-field side midplane is included and the impact of neutral density fluctuations on D_α light emission investigated. We find that neutral density fluctuations affect the D_α emission. In particular, at a radial distance from the gas puff smaller than the neutral mean free path, neutral density fluctuations are anti-correlated with plasma density, electron temperature, and D_α fluctuations. It follows that the neutral fluctuations reduce the D_α emission in most of the observed region and, therefore, have to be taken into account when interpreting the amplitude of the D_α emission. On the other hand, higher order statistical moments (skewness, kurtosis) and turbulence characteristics (such as correlation length, or the autocorrelation time) are not significantly affected by the neutral fluctuations. At distances from the gas puff larger than the neutral mean free path, a non-local shadowing effect influences the neutral density fluctuations. There, the D_α fluctuations are correlated with the neutral density fluctuations, and the high-order statistical moments and measurements of other turbulence properties are strongly affected by the neutral density fluctuations.

  7. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    International Nuclear Information System (INIS)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco

    2012-01-01

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  8. Phase-contrast enhanced mammography: A new diagnostic tool for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhentian; Thuering, Thomas; David, Christian; Roessl, Ewald; Trippel, Mafalda; Kubik-Huch, Rahel A.; Singer, Gad; Hohl, Michael K.; Hauser, Nik; Stampanoni, Marco [Swiss Light Source, Paul Scherrer Institut, 5232 Villigen (Switzerland); Laboratory for Micro and Nanotechnology, Paul Scherrer Institut, 5232 Villigen (Switzerland); Philips Technologie GmbH, Roentgenstrasse 24, 22335 Hamburg (Germany); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Radiology, Kantonsspital Baden, 5404 Baden (Switzerland); Institute of Pathology, Kantonsspital Baden, 5404 Baden (Switzerland); Department of Gynecology and Obstetrics, Interdisciplinary Breast Center Baden, Kantonsspital Baden, 5404 Baden (Switzerland); Swiss Light Source, Paul Scherrer Institut, 5232 Villigen, Switzerland and Institute for Biomedical Engineering, University and ETH Zuerich, 8092 Zuerich (Switzerland)

    2012-07-31

    Phase contrast and scattering-based X-ray imaging can potentially revolutionize the radiological approach to breast imaging by providing additional and complementary information to conventional, absorption-based methods. We investigated native, non-fixed whole breast samples using a grating interferometer with an X-ray tube-based configuration. Our approach simultaneously recorded absorption, differential phase contrast and small-angle scattering signals. The results show that this novel technique - combined with a dedicated image fusion algorithm - has the potential to deliver enhanced breast imaging with complementary information for an improved diagnostic process.

  9. Magnetic resonance imaging of the shoulder: a review of potential sources of diagnostic errors

    International Nuclear Information System (INIS)

    Carroll, K.W.; Helms, C.A.

    2002-01-01

    Shoulder magnetic resonance (MR) imaging and MR arthrography are frequently utilized in the evaluation of shoulder pain and instability. The clinical scenario and imaging findings may be confusing to clinicians and radiologists and may present diagnostic challenges for those involved in evaluating and treating shoulder pathology. Often rotator cuff and labral abnormalities may be coexistent, clinical manifestations of denervation syndromes may be confusing to clinicians, and normal anatomic variations, imaging pitfalls, and various artifacts may cause dilemmas for the radiologist. This article will review the most frequently encountered mimickers and pitfalls of MR imaging of the shoulder. (orig.)

  10. Development of horn antenna mixer array with internal local oscillator module for microwave imaging diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Kuwahara, D., E-mail: dkuwahar@cc.tuat.ac.jp [Department of Mechanical Systems Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo 184-8588 (Japan); Ito, N. [Department of Intelligent System Engineering, Ube National College of Technology, Ube, Yamaguchi 755-8555 (Japan); Nagayama, Y. [Department of Helical Plasma Research, National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Yoshinaga, T. [Department of Applied Physics, National Defense Academy, Yokosuka, Kanagawa 239-0811 (Japan); Yamaguchi, S. [Department of Pure and Applied Physics, Kansai University, Suita, Osaka 564-8680 (Japan); Yoshikawa, M.; Kohagura, J. [Graduate School of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan); Sugito, S. [Equipment Development Center, Institute for Molecular Science, Okazaki, Aichi 444-8585 (Japan); Kogi, Y. [Department of Information Electronics, Fukuoka Institute of Technology, Fukuoka, Fukuoka 811-0295 (Japan); Mase, A. [Art, Science and Technology Center for Cooperative Research, Kyusyu University, Kasuga, Fukuoka 816-8580 (Japan)

    2014-11-15

    A new antenna array is proposed in order to improve the sensitivity and complexity of microwave imaging diagnostics systems such as a microwave imaging reflectometry, a microwave imaging interferometer, and an electron cyclotron emission imaging. The antenna array consists of five elements: a horn antenna, a waveguide-to-microstrip line transition, a mixer, a local oscillation (LO) module, and an intermediate frequency amplifier. By using an LO module, the LO optics can be removed, and the supplied LO power to each element can be equalized. We report details of the antenna array and characteristics of a prototype antenna array.

  11. From molecular imaging to systems diagnostics: Time for another paradigm shift?

    International Nuclear Information System (INIS)

    Li, King C.P.

    2009-01-01

    The term 'Molecular Imaging' has hit the consciousness of radiologists only in the past decade although many of the concepts that molecular imaging encompasses has been practiced in biomedical imaging, especially in nuclear medicine, for many decades. Many new imaging techniques have allowed us to interrogate biologic events at the cellular and molecular level in vivo in four dimensions but the challenge now is to translate these techniques into clinical practice in a way that will enable us to revolutionize healthcare delivery. The purpose of this article is to introduce the term 'Systems Diagnostics' and examine how radiologists can become translators of disparate sources of information into medical decisions and therapeutic actions.

  12. Efficient medical image access in diagnostic environments with limited resources

    Directory of Open Access Journals (Sweden)

    José Eduardo Venson

    Full Text Available Abstract Introduction A medical application running outside the workstation environment has to deal with several constraints, such as reduced available memory and low network bandwidth. The aim of this paper is to present an approach to optimize the data flow for fast image transfer and visualization on mobile devices and remote stationary devices. Methods We use a combination of client- and server-side procedures to reduce the amount of information transferred by the application. Our approach was implemented on top of a commercial PACS and evaluated through user experiments with specialists in typical diagnosis tasks. The quality of the system outcome was measured in relation to the accumulated amount of network data transference and the amount of memory used in the host device. Besides, the system's quality of use (usability was measured through participants’ feedback. Results Contrarily to previous approaches, ours keeps the application within the memory constraints, minimizing data transferring whenever possible, allowing the application to run on a variety of devices. Moreover, it does that without sacrificing the user experience. Experimental data point that over 90% of the users did not notice any delays or degraded image quality, and when they did, they did not impact on the clinical decisions. Conclusion The combined activities and orchestration of our methods allow the image viewer to run on resource-constrained environments, such as those with low network bandwidth or little available memory. These results demonstrate the ability to explore the use of mobile devices as a support tool in the medical workflow.

  13. Differential diagnostic features of the radionuclide scrotal image

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1977-01-01

    Differential diagnosis of scrotal lesions is aided by correlating radionuclide images with clinical findings. Subacute torsion is associated with peripheral hyperemia and can be mistaken for an inflammatory process; however, in a review of 128 studies, torsion and orchiectomy were the only processes encountered which had a center truly devoid of activity on the tissue phase compared to the normal side. Other lesions such as acute inflammation, abscess, hematoma, and hemorrhagic tumor may superficially appear to lack central activity but invariably contain at least as much activity when compared to the normal side.

  14. A complex communicating bronchopulmonary foregut malformation: diagnostic imaging and pathogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Sumner, T.E.; Auringer, S.T.; Cox, T.D. [Department of Radiology, Bowman Gray School of Medicine, Wake Forest University, Medical Center Boulevard, Winston-Salem, NC 27157-1088 (United States)

    1997-10-01

    We report a newborn with an esophageal lung, a rare type of communicating bronchopulmonary foregut malformation (CBPFM). Associated findings included esophageal atresia, tracheoesophageal fistula (TEF) to the distal esophagus, duodenal stenosis with annular pancreas, imperforate anus, vertebral anomalies and ambiguous genitalia. Radiologic evaluation included chest radiographs, esophagrams, chest ultrasound and chest CT. After colostomy and surgical repair of duodenal stenosis and TEF, a right thoracotomy was performed to treat an esophageal lung. Radiologic features of this unusual variant of CBPFM are presented. Accurate preoperative imaging diagnosis is essential for planning surgical treatment of an esophageal lung. (orig.). With 1 fig.

  15. Etiologic diagnostic value of angioscan imaging in cerebromeningeal hemorrhage

    International Nuclear Information System (INIS)

    Bourree, Y.; Plassart, F.; Rieux, D.; Caron-Poitreau, C.

    1987-01-01

    Etiologic diagnosis of cerebromeningeal hemorrhage was suspected on CT scan without contrast imaging as a function of distribution of cisternal hyperdensities and/or topography of intracerebral hematomas and/or distribution of parenchymatous hypodensities. It was established in 90 % of cases by results of angioscan (type and site of vascular malformation causing the cerebromeningeal hemorrhage are defined with this percent exactitude). Cerebral arteriography provides indispensable precise morphologic data on the vascular malformation: exact site of aneurysm or arteriovenous malformation, orientation of the aneurysm and presence or absence of a collar. It is therefore irreplaceable and will be guided by data from the angio-CT scan [fr

  16. Differential diagnostic features of the radionuclide scrotal image

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1977-01-01

    Differential diagnosis of scrotal lesions is aided by correlating radionuclide images with clinical findings. Subacute torsion is associated with peripheral hyperemia and can be mistaken for an inflammatory process; however, in a review of 128 studies, torsion and orchiectomy were the only processes encountered which had a center truly devoid of activity on the tissue phase compared to the normal side. Other lesions such as acute inflammation, abscess, hematoma, and hemorrhagic tumor may superficially appear to lack central activity but invariably contain at least as much activity when compared to the normal side

  17. Diagnostic imaging in COPD; Radiologische Diagnostik bei COPD

    Energy Technology Data Exchange (ETDEWEB)

    Owsijewitsch, Michael; Ley-Zaporozhan, Julia [Universitaetsklinik Heidelberg (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Eichinger, Monika [Deutsches Krebsforschungszentrum (DKFZ), Heidelberg (Germany). Abt. Radiologie

    2011-03-15

    COPD is a heterogeneous disease defined by expiratory airflow limitation. Airflow limitation is caused by a variable combination of emphysematous destruction of lung parenchyma and small airway obstruction. Only advanced emphysema can be diagnosed by chest X-ray. Less severe emphysema and changes in small airways are commonly diagnosed by computed tomography. Typical visual appearance of pathologic changes in lung parenchyma and airways of COPD patients are presented, furthermore methods for quantitative assessment of these changes and the crucial role of imaging for surgical and bronchoscopic treatment in COPD are discussed. (orig.)

  18. A complex communicating bronchopulmonary foregut malformation: diagnostic imaging and pathogenesis

    International Nuclear Information System (INIS)

    Sumner, T.E.; Auringer, S.T.; Cox, T.D.

    1997-01-01

    We report a newborn with an esophageal lung, a rare type of communicating bronchopulmonary foregut malformation (CBPFM). Associated findings included esophageal atresia, tracheoesophageal fistula (TEF) to the distal esophagus, duodenal stenosis with annular pancreas, imperforate anus, vertebral anomalies and ambiguous genitalia. Radiologic evaluation included chest radiographs, esophagrams, chest ultrasound and chest CT. After colostomy and surgical repair of duodenal stenosis and TEF, a right thoracotomy was performed to treat an esophageal lung. Radiologic features of this unusual variant of CBPFM are presented. Accurate preoperative imaging diagnosis is essential for planning surgical treatment of an esophageal lung. (orig.). With 1 fig

  19. Diagnostic Accuracy of Clinical Examination and Imaging Findings for Identifying Subacromial Pain.

    Science.gov (United States)

    Cadogan, Angela; McNair, Peter J; Laslett, Mark; Hing, Wayne A

    2016-01-01

    The diagnosis of subacromial pathology is limited by the poor accuracy of clinical tests for specific pathologies. The aim of this study was to estimate the diagnostic accuracy of clinical examination and imaging features for identifying subacromial pain (SAP) defined by a positive response to diagnostic injection, and to evaluate the influence of imaging findings on the clinical diagnosis of SAP. In a prospective, diagnostic accuracy design, 208 consecutive patients presenting to their primary healthcare practitioner for the first time with a new episode of shoulder pain were recruited. All participants underwent a standardized clinical examination, shoulder x-ray series and diagnostic ultrasound scan. Results were compared with the response to a diagnostic block of xylocaineTM injected into the SAB under ultrasound guidance using ≥80% post-injection reduction in pain intensity as the positive anaesthetic response (PAR) criterion. Diagnostic accuracy statistics were calculated for combinations of clinical and imaging variables demonstrating the highest likelihood of a PAR. A PAR was reported by 34% of participants. In participants with no loss of passive external rotation, combinations of three clinical variables (anterior shoulder pain, strain injury, absence of symptoms at end-range external rotation (in abduction)) demonstrated 100% specificity for a PAR when all three were positive (LR+ infinity; 95%CI 2.9, infinity). A full-thickness supraspinatus tear on ultrasound increased the likelihood of a PAR irrespective of age (specificity 98% (95%CI 94, 100); LR+ 6.2; 95% CI 1.5, 25.7)). Imaging did not improve the ability to rule-out a PAR. Combinations of clinical examination findings and a full-thickness supraspinatus tear on ultrasound scan can help confirm, but not exclude, the presence of subacromial pain. Other imaging findings were of limited value for diagnosing SAP.

  20. Oncology Patient Perceptions of the Use of Ionizing Radiation in Diagnostic Imaging.

    Science.gov (United States)

    Steele, Joseph R; Jones, Aaron K; Clarke, Ryan K; Giordano, Sharon H; Shoemaker, Stowe

    2016-07-01

    To measure the knowledge of oncology patients regarding use and potential risks of ionizing radiation in diagnostic imaging. A 30-question survey was developed and e-mailed to 48,736 randomly selected patients who had undergone a diagnostic imaging study at a comprehensive cancer center between November 1, 2013 and January 31, 2014. The survey was designed to measure patients' knowledge about use of ionizing radiation in diagnostic imaging and attitudes about radiation. Nonresponse bias was quantified by sending an abbreviated survey to patients who did not respond to the original survey. Of the 48,736 individuals who were sent the initial survey, 9,098 (18.7%) opened it, and 5,462 (11.2%) completed it. A total of 21.7% of respondents reported knowing the definition of ionizing radiation; 35.1% stated correctly that CT used ionizing radiation; and 29.4% stated incorrectly that MRI used ionizing radiation. Many respondents did not understand risks from exposure to diagnostic doses of ionizing radiation: Of 3,139 respondents who believed that an abdominopelvic CT scan carried risk, 1,283 (40.9%) believed sterility was a risk; 669 (21.3%) believed heritable mutations were a risk; 657 (20.9%) believed acute radiation sickness was a risk; and 135 (4.3%) believed cataracts were a risk. Most patients and caregivers do not possess basic knowledge regarding the use of ionizing radiation in oncologic diagnostic imaging. To ensure health literacy and high-quality patient decision making, efforts to educate patients and caregivers should be increased. Such education might begin with information about effects that are not risks of diagnostic imaging. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Application of Six Sigma methodology to a diagnostic imaging process.

    Science.gov (United States)

    Taner, Mehmet Tolga; Sezen, Bulent; Atwat, Kamal M

    2012-01-01

    This paper aims to apply the Six Sigma methodology to improve workflow by eliminating the causes of failure in the medical imaging department of a private Turkish hospital. Implementation of the design, measure, analyse, improve and control (DMAIC) improvement cycle, workflow chart, fishbone diagrams and Pareto charts were employed, together with rigorous data collection in the department. The identification of root causes of repeat sessions and delays was followed by failure, mode and effect analysis, hazard analysis and decision tree analysis. The most frequent causes of failure were malfunction of the RIS/PACS system and improper positioning of patients. Subsequent to extensive training of professionals, the sigma level was increased from 3.5 to 4.2. The data were collected over only four months. Six Sigma's data measurement and process improvement methodology is the impetus for health care organisations to rethink their workflow and reduce malpractice. It involves measuring, recording and reporting data on a regular basis. This enables the administration to monitor workflow continuously. The improvements in the workflow under study, made by determining the failures and potential risks associated with radiologic care, will have a positive impact on society in terms of patient safety. Having eliminated repeat examinations, the risk of being exposed to more radiation was also minimised. This paper supports the need to apply Six Sigma and present an evaluation of the process in an imaging department.

  2. Pulled elbow in infancy: diagnostic role of imaging

    International Nuclear Information System (INIS)

    Scapinelli, Raffaele; Borgo, Andrea

    2005-01-01

    Purpose. Pulled elbow is a common injury in infancy. Typically the child, after a sudden pull, refuses to use the arm. The history and clinical findings are sufficient to make the diagnosis, and radiography or ultrasonography are not necessary. When imaging procedures are performed, a few small signs are useful to confirm the diagnosis of pulled elbow. Materials and methods. The authors reviewed the radiographic and ultrasonographic signs reported to be suggestive of pulled elbow (increased radio-condylar distance, increased radio-coronoid distance, proximal radio-ulnar diastasis, deviation of the radio-condylar line) and attempted to confirm their presence in children affected by this trauma. Results. Increased radio-condylar and radio-coronoid distance were present in 8 of 8 cases: proximal radio-ulnar diastasis and deviation of the radio-condylar line were inconsistently present. Ultrasonography gave contradictory results. Conclusions. In typical cases of pulled elbow, radiography or ultrasonography are not necessary for diagnosis and treatment. imaging procedures are recommended only in the case of non typical history, in the presence of deformity or traumatic skin lesions and in children over six years of age. Increased radio-coronoid distance on the affected side is the most frequent and visible sign, which can confirm the diagnosis of pulled elbow. Increased radio-condylar distance is also present, but it is not easy to visualize. Proximal radio-ulnar diastasis and deviation of the radio-condylar line are inconstant. Ultrasonography is difficult to standardize [it

  3. Predicting diagnostic error in Radiology via eye-tracking and image analytics: Application in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Sophie [ORNL; Pinto, Frank M [ORNL; Morin-Ducote, Garnetta [University of Tennessee, Knoxville (UTK); Hudson, Kathy [University of Tennessee, Knoxville (UTK); Tourassi, Georgia [ORNL

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels. Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from 4 Radiology residents and 2 breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADs images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated. Results: Diagnostic error can be predicted reliably by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model (AUC=0.79). Personalized user modeling was far more accurate for the more experienced readers (average AUC of 0.837 0.029) than for the less experienced ones (average AUC of 0.667 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features. Conclusions: Diagnostic errors in mammography can be predicted reliably by leveraging the radiologists gaze behavior and image content.

  4. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Sophie; Tourassi, Georgia D. [Biomedical Science and Engineering Center, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Pinto, Frank [School of Engineering, Science, and Technology, Virginia State University, Petersburg, Virginia 23806 (United States); Morin-Ducote, Garnetta; Hudson, Kathleen B. [Department of Radiology, University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37920 (United States)

    2013-10-15

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.

  5. Diagnostic evaluation of brain SPECT imaging in diseases of nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Yongsheng, Jiang; Chengmo, Zhu; Jixian, Zhang; Weijia, Tian [Shanghai Second Medical Univ. (China). Ruijing Hospital

    1992-11-01

    The dynamic distributions of home made ECD and the Amersham brain SPECT imaging agent 'Ceretec' in normal person as well as their diagnostic use in diseases of nervous system were investigated. Semi-quantitative analysis combined with direct observation was more accurate for the diagnosis. Aside from cerebrovascular diseases, SPECT brain imaging has its unique value for the diagnosis of transient ischemic attack, Alzheimer disease, multiple ischemic dementia and epilepsy etc.

  6. Preparation of photo an video images during foot diagnostics in stress condition

    International Nuclear Information System (INIS)

    Katsarov, V; Stoyanov, K.; Panchev, P.; Belcheva, J.; Atanasov, A.

    2008-01-01

    The aim of this work is to present some practical issues concerning image scanning, processing and software application in orthopedics and traumatology for foot diagnostic purposes. Basic concepts in optical scanning, multi-position photography and technology with high informational value have been discussed. The use of Slide show, Clip and Mpeg graphic formats during preparation for capture and image processing has been also demonstrated

  7. Diagnostic imaging of the equine fetlock region using radiography and ultrasonography. Part 2: the bony disorders.

    Science.gov (United States)

    Vanderperren, Katrien; Saunders, Jimmy H

    2009-08-01

    The metacarpophangeal/metatarsophalangeal (fetlock) joint in the horse is commonly associated with equine lameness and diagnostic imaging is routinely used to investigate disorders of the joint and its surrounding tissues. This review describes the osseous disorders of the fetlock as well as the technical aspects of taking radiographic and ultrasonographic images of the different lesions. In current clinical practice, a combination of radiography and ultrasonography is still the most frequently used approach to arrive at a diagnosis.

  8. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    International Nuclear Information System (INIS)

    Voisin, Sophie; Tourassi, Georgia D.; Pinto, Frank; Morin-Ducote, Garnetta; Hudson, Kathleen B.

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content

  9. Radiation exposure from diagnostic imaging in young patients with testicular cancer

    International Nuclear Information System (INIS)

    Sullivan, C.J.; Twomey, M.; O'Regan, K.N.; Murphy, K.P.; Maher, M.M.; O'Connor, O.J.; McLaughlin, P.D.; Power, D.G.

    2015-01-01

    Risks associated with high cumulative effective dose (CED) from radiation are greater when imaging is performed on younger patients. Testicular cancer affects young patients and has a good prognosis. Regular imaging is standard for follow-up. This study quantifies CED from diagnostic imaging in these patients. Radiological imaging of patients aged 18-39 years, diagnosed with testicular cancer between 2001 and 2011 in two tertiary care centres was examined. Age at diagnosis, cancer type, dose-length product (DLP), imaging type, and frequency were recorded. CED was calculated from DLP using conversion factors. Statistical analysis was performed with SPSS. In total, 120 patients with a mean age of 30.7 ± 5.2 years at diagnosis had 1,410 radiological investigations. Median (IQR) surveillance was 4.37 years (2.0-5.5). Median (IQR) CED was 125.1 mSv (81.3-177.5). Computed tomography accounted for 65.3 % of imaging studies and 98.3 % of CED. We found that 77.5 % (93/120) of patients received high CED (>75 mSv). Surveillance time was associated with high CED (OR 2.1, CI 1.5-2.8). Survivors of testicular cancer frequently receive high CED from diagnostic imaging, mainly CT. Dose management software for accurate real-time monitoring of CED and low-dose CT protocols with maintained image quality should be used by specialist centres for surveillance imaging. (orig.)

  10. Radiation exposure from diagnostic imaging in young patients with testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, C.J.; Twomey, M.; O' Regan, K.N. [Cork and Mercy University Hospitals, Department of Radiology, Cork (Ireland); Murphy, K.P.; Maher, M.M.; O' Connor, O.J. [Cork and Mercy University Hospitals, Department of Radiology, Cork (Ireland); University College Cork, Department of Radiology, Cork (Ireland); McLaughlin, P.D. [Cork and Mercy University Hospitals, Department of Radiology, Cork (Ireland); Vancouver General Hospital, Department of Emergency and Trauma Radiology, Vancouver, British Columbia (Canada); Power, D.G. [Cork and Mercy University Hospitals, Department of Medical Oncology, Cork (Ireland)

    2015-04-01

    Risks associated with high cumulative effective dose (CED) from radiation are greater when imaging is performed on younger patients. Testicular cancer affects young patients and has a good prognosis. Regular imaging is standard for follow-up. This study quantifies CED from diagnostic imaging in these patients. Radiological imaging of patients aged 18-39 years, diagnosed with testicular cancer between 2001 and 2011 in two tertiary care centres was examined. Age at diagnosis, cancer type, dose-length product (DLP), imaging type, and frequency were recorded. CED was calculated from DLP using conversion factors. Statistical analysis was performed with SPSS. In total, 120 patients with a mean age of 30.7 ± 5.2 years at diagnosis had 1,410 radiological investigations. Median (IQR) surveillance was 4.37 years (2.0-5.5). Median (IQR) CED was 125.1 mSv (81.3-177.5). Computed tomography accounted for 65.3 % of imaging studies and 98.3 % of CED. We found that 77.5 % (93/120) of patients received high CED (>75 mSv). Surveillance time was associated with high CED (OR 2.1, CI 1.5-2.8). Survivors of testicular cancer frequently receive high CED from diagnostic imaging, mainly CT. Dose management software for accurate real-time monitoring of CED and low-dose CT protocols with maintained image quality should be used by specialist centres for surveillance imaging. (orig.)

  11. Gold-manganese nanoparticles for targeted diagnostic and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Murph, Simona Hunyadi [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-11-10

    Imagine the possibility of non-invasive, non-radiation based Magnetic resonance imaging (MRI) in combating cardiac disease. Researchers at the Savannah River National Laboratory (SRNL) are developing a process that would use nanotechnology in a novel, targeted approach that would allow MRIs to be more descriptive and brighter, and to target specific organs. Researchers at SRNL have discovered a way to use multifunctional metallic gold-manganese nanoparticles to create a unique, targeted positive contrast agent. SRNL Senior Scientist Dr. Simona Hunyadi Murph says she first thought of using the nanoparticles for cardiac disease applications after learning that people who survive an infarct exhibit up to 15 times higher rate of developing chronic heart failure, arrhythmias and/or sudden death compared to the general population. Without question, nanotechnology will revolutionize the future of technology. The development of functional nanomaterials with multi-detection modalities opens up new avenues for creating multi-purpose technologies for biomedical applications.

  12. Diagnostic value of susceptibility weighted image in diffuse axonal injury

    International Nuclear Information System (INIS)

    Liang Changsong; Chen Zhong; Ye Wenqin; Chen Zewen; Liao Miaoyou; Ma Chaojin; Li Weifeng

    2010-01-01

    Objective: To investigate the value of SWI sequence in diagnosis of DAI by analyzing the MRI images of DAI. Methods: The MRI data of 30 cases with DAI diagnosed by clinic were analyzed retrospectively. The signal intensity features and detection rate of lesions were compared in all sequences. Results: SET 1 WI sequence had the lowest sensitivity, secondly was T 2 WI sequence. DAI showed as long T 1 long T 2 signal. Some lesions could be detected with FLAIR, appearing as nodular or patchy hyperintensity. More lesions were detected with SWI sequence than with other sequences. DAI lesions mainly located in the junctional zone of cortex and medulla, basal ganglia, corpus callosum, brain stem and cerebellum. It appeared as needle tip, mottling, nodular hypointensity in SWI sequence. Conclusion: SWI can detect more lesions in cases with DAI than other sequences. It can be an additional sequence in MRI examination for the patients suspicioused with DAI. (authors)

  13. Valve Calcification in Aortic Stenosis: Etiology and Diagnostic Imaging Techniques

    Directory of Open Access Journals (Sweden)

    María Manuela Izquierdo-Gómez

    2017-01-01

    Full Text Available Aortic stenosis is the most common valvulopathy in the Western world. Its prevalence has increased significantly in recent years due to population aging; hence, up to 8% of westerners above the age of 84 now have severe aortic stenosis (Lindroos et al., 1993. This causes increased morbidity and mortality and therein lies the importance of adequate diagnosis and stratification of the degree of severity which allows planning the best therapeutic option in each case. Long understood as a passive age-related degenerative process, it is now considered a rather more complex entity involving mechanisms and factors similar to those of atherosclerosis (Stewart et al., 1997. In this review, we summarize the pathophysiological mechanisms underlying the onset and progression of the disease and analyze the current role of cardiac imaging techniques for diagnosis.

  14. Diagnostic imaging of limbs in children with acute leukemia

    International Nuclear Information System (INIS)

    Song Yingru; Li Chenhui; Li Guo; Ye Wei; Huang Zhongkui; Long Liling; Luo Jianming

    2011-01-01

    Objective: To evaluate X-ray and MRI features of limbs in childhood acute leukemia. Methods: Thirteen children with acute leukemia in our pediatric hematology ward were recruited. All patients were pathologically diagnosed by bone marrow aspiration and complained of bone or joint pain in the first visit. Conventional X-ray and MRI examinations of algesic sites were performed before clinical treatment and after complete remission. MR images were obtained with SE-T 1 WI, SE-T 2 WI and T 2 WI-fat suppressed sequences and symmetrical bilateralism was requested while scanning. X-ray and MRI manifestations were evaluated and compared. Results: All 13 patients had received X-ray examinations. Among them, 6 had normal X-ray findings, whereas the other 7 (14 sites) showed various abnormalities including radiolucent metaphyseal bands (5 sites), periosteal reaction (3 sites), osteapenia (2 sites), mixed lesions (lysis- sclerosis, 1 site), and permeative pattern (3 sites). The number of patients for MRI examinations was 8 (11 sites). Among them, 6 (9 sites) showed bone marrow infiltration and bone marrow necrosis accompanied by normal X-ray findings, another 2 (2 sites) showed bone marrow infiltration associated with radiographic abnormalities of periosteal reaction and radiolucent metaphyseal bands. Four cases were followed up within 1 week when reached complete remission by chemotherapy. MR images features included reduced sizes of bone marrow infiltration lesions associated with increased signal intensity on T 1 WI, and disappearance of double-line sign on bone marrow necrosis accompanied by signal homogenization. However, the radiograph before and after treatment in the same cases did not differ significantly. Conclusions: MRI was earlier and more comprehensive in showing limbs bone marrow abnormality than radiogram in acute leukemia children with chief complaint of osteoarticular pains. MRI might be one of indicators in following up therapeutic effect for AL children with

  15. Natural display mode for digital DICOM-conformant diagnostic imaging.

    Science.gov (United States)

    Peters, Klaus-Ruediger; Ramsby, Gale R

    2002-09-01

    The authors performed this study to investigate the verification of the contrast display properties defined by the digital imaging and communication in medicine (DICOM) PS (picture archiving and communication system [PACS] standard) 3.14-2001 gray-scale display function standard and their dependency on display luminance range and video signal bandwidth. Contrast sensitivity and contrast linearity of DICOM-conformant displays were measured in just-noticeable differences (JNDs) on special perceptual contrast test patterns. Measurements were obtained six times at various display settings under dark room conditions. Display luminance range and video bandwidth had a significant effect on contrast perception. The perceptual promises of the standard could be established only with displays that were calibrated to a unity contrast resolution, at which the number of displayed intensity steps was equal to the number of perceivable contrast steps (JNDs). Such display conditions provide for visual perception information at the level of single-step contrast sensitivity and full-range contrast linearity. These "natural display" conditions also help minimize the Mach banding effects that otherwise reduce contrast sensitivity and contrast linearity. Most, if not all, conventionally used digital display modalities are driven with a contrast resolution larger than 1. Such conditions reduce contrast perception when compared with natural imaging conditions. The DICOM-conformant display conditions at unity contrast resolution were characterized as the "natural display" mode, and, thus, the authors a priori recommend them as being useful for making a primary diagnosis with PACS and teleradiology and as a standard for psychophysical research and performance measurements.

  16. Diagnostic imaging in neonatal stroke; Bildgebende Diagnostik des Neonatal stroke

    Energy Technology Data Exchange (ETDEWEB)

    Kuhle, S.; Ipsiroglu, O.; Weninger, M. [Universitaetsklinik fuer Kinder- und Jugendheilkunde, Wien (Austria). Abt. fuer Neonatologie, angeborene Stoerungen und Intensivmedizin; Puig, S.; Prayer, D. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2000-01-01

    A cerebral artery infarction is an important differential diagnosis in the newborn with neurological abnormalities. Based on clinical data, its incidence is estimated to be 1 in 4000 newborns. Since the course is often subclinical, the true incidence is probably higher. Diagnosis: Cerebral ultrasound and Doppler sonography as readily available screening tools play a central role in the initial diagnosis of neonatal cerebral infarction. Definitive diagnosis is made by computed tomography or magnetic resonance imaging. Beside symptomatic anticonvulsive therapy, treatment aims at the prevention of secondary ischemic injury. Discussion: Three term infants with different clinical courses of neonatal stroke are presented to sensitize the clinician and the radiologist for this probably underdiagnosed entity. The role of imaging modalities in the diagnosis and follow-up of neonatal cerebral infarction is discussed. (orig.) [German] Ein Infarkt im Stromgebiet der Zerebralarterien stellt eine wichtige Differentialdiagnose bei neurologischen Auffaelligkeiten in der Neonatalperiode dar. Die Inzidenz wird anhand von klinischer Daten auf 1:4000 Lebendgeborene geschaetzt. Da der Verlauf oft subklinisch ist, liegt die wahre Inzidenz wahrscheinlich hoeher. Diagnose: Bei der Diagnosestellung kommen dem Schaedelultraschall und der Doppelsonographie als leicht verfuegbaren Screening-Methoden eine zentrale Rolle zu. Die definitive Diagnose wird, je nach Verfuegbarkeit, mittels Computertomographie oder Kernspintomographie gestellt. Die Behandlung ist neben der symptomatischen (antikonvulsiven) Therapie auf die Vermeidung von ischaemischen Sekundaerschaeden gerichtet. Diskussion: Wir wollen mit der vorliegenden Arbeit anhand von 3 Kindern mit verschiedenen klinischen Verlaeufen eines sog. Neonatal stroke den Stellenwert der bildgebenden Verfahren bei der Diagnostik und Verlaufskontrolle aufzeigen und die Sensibilitaet fuer dieses vermutlich unterdiagnostizierte Krankheitsbild erhoehen

  17. Evidence-based development of a diagnosis-dependent therapy planning system and its implementation in modern diagnostic software.

    Science.gov (United States)

    Ahlers, M O; Jakstat, H A

    2005-07-01

    The prerequisite for structured individual therapy of craniomandibular dysfunctions is differential diagnostics. Suggestions for the structured recording of findings and their structured evaluation beyond the global diagnosis of "craniomandibular disorders" have been published. Only this structured approach enables computerization of the diagnostic process. The respective software is available for use in practice (CMDcheck for CMD screening, CMDfact for the differential diagnostics). Based on this structured diagnostics, knowledge-based therapy planning is also conceivable. The prerequisite for this would be a model of achieving consensus on the indicated forms of therapy related to the diagnosis. Therefore, a procedure for evidence-based achievement of consensus on suitable forms of therapy in CMD was developed first in multicentric cooperation, and then implemented in corresponding software. The clinical knowledge of experienced specialists was included consciously for the consensus achievement process. At the same time, anonymized mathematical statistical evaluations were used for control and objectification. Different examiners form different departments of several universities working independently of one another assigned the theoretically conceiveable therapeutic alternatives to the already published diagnostic scheme. After anonymization, the correlation of these assignments was then calculated mathematically. For achieving consensus in those cases for which no agreement initally existed, agreement was subsequently arrived at in the course of a consensus conference on the basis of literature evaluations and the discussion of clinical case examples. This consensus in turn finally served as the basis of a therapy planner implemented in the above-mentioned diagnostic software CMDfact. Contributing to quality assurance, the principles of programming this assistant as well as the interface for linking into the diagnostic software are documented and also published

  18. Multidimensional anatomy of 'modern type depression' in Japan: A proposal for a different diagnostic approach to depression beyond the DSM-5.

    Science.gov (United States)

    Kato, Takahiro A; Hashimoto, Ryota; Hayakawa, Kohei; Kubo, Hiroaki; Watabe, Motoki; Teo, Alan R; Kanba, Shigenobu

    2016-01-01

    Japan's prototype of depression was traditionally a melancholic depression based on the premorbid personality known as shūchaku-kishitsu proposed by Mitsuzo Shimoda in the 1930s. However, since around 2000, a novel form of depression has emerged among Japanese youth. Called 'modern type depression (MTD)' by the mass media, the term has quickly gained popularity among the general public, though it has not been regarded as an official medical term. Likewise, lack of consensus guidelines for its diagnosis and treatment, and a dearth of scientific literature on MTD has led to confusion when dealing with it in clinical practice in Japan. In this review article, we summarize and discuss the present situation and issues regarding MTD by focusing on historical, diagnostic, psychosocial, and cultural perspectives. We also draw on international perspectives that begin to suggest that MTD is a phenomenon that may exist not only in Japan but also in many other countries with different sociocultural and historical backgrounds. It is therefore of interest to establish whether MTD is a culture-specific phenomenon in Japan or a syndrome that can be classified using international diagnostic criteria as contained in the ICD or the DSM. We propose a novel diagnostic approach for depression that addresses MTD in order to combat the current confusion about depression under the present diagnostic systems. © 2015 The Authors. Psychiatry and Clinical Neurosciences © 2015 Japanese Society of Psychiatry and Neurology.

  19. Multidimensional anatomy of ‘modern type depression’ in Japan: A proposal for a different diagnostic approach to depression beyond the DSM-5

    Science.gov (United States)

    Kato, Takahiro A.; Hashimoto, Ryota; Hayakawa, Kohei; Kubo, Hiroaki; Watabe, Motoki; Teo, Alan R.; Kanba, Shigenobu

    2017-01-01

    Japan’s prototype of depression was traditionally a melancholic depression based on the premorbid personality known as shūchaku-kishitsu proposed by Mitsuzo Shimoda in the 1930s. However, since around 2000, a novel form of depression has emerged among Japanese youth. Called ‘modern type depression (MTD)’ by the mass media, the term has quickly gained popularity among the general public, though it has not been regarded as an official medical term. Likewise, lack of consensus guidelines for its diagnosis and treatment, and a dearth of scientific literature on MTD has led to confusion when dealing with it in clinical practice in Japan. In this review article, we summarize and discuss the present situation and issues regarding MTD by focusing on historical, diagnostic, psychosocial, and cultural perspectives. We also draw on international perspectives that begin to suggest that MTD is a phenomenon that may exist not only in Japan but also in many other countries with different sociocultural and historical backgrounds. It is therefore of interest to establish whether MTD is a culture-specific phenomenon in Japan or a syndrome that can be classified using international diagnostic criteria as contained in the ICD or the DSM. We propose a novel diagnostic approach for depression that addresses MTD in order to combat the current confusion about depression under the present diagnostic systems. PMID:26350304

  20. Research priorities for the influence of gender on diagnostic imaging choices in the emergency department setting.

    Science.gov (United States)

    Ashurst, John V; Cherney, Alan R; Evans, Elizabeth M; Kennedy Hall, Michael; Hess, Erik P; Kline, Jeffrey A; Mitchell, Alice M; Mills, Angela M; Weigner, Michael B; Moore, Christopher L

    2014-12-01

    Diagnostic imaging is a cornerstone of patient evaluation in the acute care setting, but little effort has been devoted to understanding the appropriate influence of sex and gender on imaging choices. This article provides background on this issue and a description of the working group and consensus findings reached during the diagnostic imaging breakout session at the 2014 Academic Emergency Medicine consensus conference "Gender-specific Research in Emergency Care: Investigate, Understand, and Translate How Gender Affects Patient Outcomes." Our goal was to determine research priorities for how sex and gender may (or should) affect imaging choices in the acute care setting. Prior to the conference, the working group identified five areas for discussion regarding the research agenda in sex- and gender-based imaging using literature review and expert consensus. The nominal group technique was used to identify areas for discussion for common presenting complaints to the emergency department where ionizing radiation is often used for diagnosis: suspected pulmonary embolism, suspected kidney stone, lower abdominal pain with a concern for appendicitis, and chest pain concerning for coronary artery disease. The role of sex- and gender-based shared decision-making in diagnostic imaging decisions is also raised. © 2014 by the Society for Academic Emergency Medicine.

  1. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  2. Statistical analysis and interpretation of prenatal diagnostic imaging studies, Part 2: descriptive and inferential statistical methods.

    Science.gov (United States)

    Tuuli, Methodius G; Odibo, Anthony O

    2011-08-01

    The objective of this article is to discuss the rationale for common statistical tests used for the analysis and interpretation of prenatal diagnostic imaging studies. Examples from the literature are used to illustrate descriptive and inferential statistics. The uses and limitations of linear and logistic regression analyses are discussed in detail.

  3. Balloon-assisted enteroscopy for suspected Meckel’s diverticulum and indefinite diagnostic imaging workup

    Science.gov (United States)

    Gomes, Guilherme Francisco; Bonin, Eduardo Aimore; Noda, Rafael William; Cavazzola, Leandro Totti; Bartholomei, Thiago Ferreira

    2016-01-01

    Meckel’s diverticulum (MD) is estimated to affect 1%-2% of the general population, and it represents a clinically silent finding of a congenital anomaly in up to 85% of the cases. In adults, MD may cause symptoms, such as overt occult lower gastrointestinal bleeding. The diagnostic imaging workup includes computed tomography scan, magnetic resonance imaging enterography, technetium 99m scintigraphy (99mTc) using either labeled red blood cells or pertechnetate (known as the Meckel’s scan) and angiography. The preoperative detection rate of MD in adults is low, and many patients ultimately undergo exploratory laparoscopy. More recently, however, endoscopic identification of MD has been possible with the use of balloon-assisted enteroscopy via direct luminal access, which also provides visualization of the diverticular ostium. The aim of this study was to review the diagnosis by double-balloon enteroscopy of 4 adults with symptomatic MD but who had negative diagnostic imaging workups. These cases indicate that balloon-assisted enteroscopy is a valuable diagnostic method and should be considered in adult patients who have suspected MD and indefinite findings on diagnostic imaging workup, including negative Meckel’s scan. PMID:27803776

  4. Computed tomography, nuclear medicine, ultrasound. Advanced diagnostic imaging for problematic areas in paediatric otolaryngology

    International Nuclear Information System (INIS)

    Noyek, A.M.; Friedberg, J.; Fitz, C.R.; Greyson, N.D.; Gilday, D.; Ash, J.; Miskin, M.; Rothberg, R.

    1982-01-01

    This presentation considers the diagnostic role of three major advanced imaging modalities in paediatric otolaryngology: computed tomography, nuclear medicine and ultrasound. These techniques allow for both more specific diagnosis, and for more precise understanding of the natural history of diagnoses already rendered. (Auth.)

  5. Training for thorax diagnostics. Systematic cardiopulmonary image analysis; Trainer Thoraxdiagnostik. Systematische kardiopulmonale Bildanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Kirchner, Johannes [Allgemeines Krankenhaus Hagen gem.GmbH (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie

    2010-07-01

    The training book on thorax diagnostics using image analysis is supposed to be a supplement to the usual textbooks based on comprehensive experiences of radiologists. The covered issues are the following: heart insufficiency, acute/ chronic bronchitis and pulmonary emphysema; pneumonia and tuberculosis; bronchial carcinoma; lung fibrosis, sarcoidosis and pneumoconiosis, pleural effusion and pneumothorax.

  6. Diagnostic utility of candidate definitions for demonstrating axial spondyloarthritis on magnetic resonance imaging of the spine

    DEFF Research Database (Denmark)

    Weber, Ulrich; Zhao, Zheng; Rufibach, Kaspar

    2015-01-01

    OBJECTIVE: A recent consensus statement has suggested ≥3 corner inflammatory lesions (CILs) or several corner fatty lesions (CFLs) as candidate criteria indicative of axial spondyloarthritis (SpA) on magnetic resonance imaging (MRI) of the spine. The aim of this study was to evaluate the diagnostic...

  7. Signification of modern radiology in ophthalmooncology of child age

    International Nuclear Information System (INIS)

    Gerinec, A.; Moczova, J.

    1997-01-01

    Authors in their work analyse importance of modern radiological methods in ophthalmooncology of child age. Computer tomography and magnetic resonance imaging are now very important methods for diagnostic, differential diagnostic and controlling therapeutic effects in retinoblastoma, rhabdomyosarcoma and hemangioma of the orbit and optic nerve glioma. (authors)

  8. Diagnostics

    International Nuclear Information System (INIS)

    Borer, J.; Jung, R.

    1984-01-01

    All the non interacting monitors used for the p-anti p instrumentation can be related to the use of the wall image current as induced by relativistic charged particle bunches circulating in a metallic pipe or vacuum chamber. The monitors are then classified by their type of beam coupling impedance. This allows a more generalized approach of the design of the so-called pickups. (orig./HSI)

  9. Multiple foci of splenic tissue autotransplantation: Splenosis in diagnostic imaging

    International Nuclear Information System (INIS)

    Laskowska, K.; Burzynska-Makuch, M.; Drewa, S.; Lasek, W.; Pilecki, S.; Junik, R.

    2005-01-01

    Splenosis is usually defined as an autotransplantation of lienal tissue in the abdomen or cest following trauma to the spleen and/or splenectomy. The authors present the case of patient 15 years after a splenectomy performed because of extensive abdominal trauma. A new computed tomographic (CT) scan of the abdomen revealed multiple homogenous nodules, different in size, spread in the abdomen. Their density was characteristic of spleen. Ultrasound examination revealed only the largest tumors, located close to the liver and apparently isoechogenic to it. Static scintigraphy and SPECT were performed to prove the presence of splenosis. After treating the patient with colloid sulfide, multiple foci of increased radioisotope accumulation were identified in the abdomen, extrahepatic at the same locations as the masses visible on the CT scans, which were comparable to splenic tissue. Nodules revealed during CT or abdominal US in patients previously treated by splenectomy require further imaging with static scintigraphy of the liver and spleen in order to confirm or exclude splenosis. (author)

  10. Diagnostic imaging of severe rectus sheath hematoma complicating anticoagulant therapy

    International Nuclear Information System (INIS)

    Blum, A.; Bui, P.; Boccaccini, H.; Bresler, L.; Claudon, M.; Boissel, P.; Regent, D.

    1995-01-01

    CT were performed in thirteen patients (12 women, 1 man) aged from 53 to 90 (mean age, 74) with severe RSH. Five patients also underwent ultrasound examination and three MR examination. Nine patients (69%) were receiving subcutaneous injection of heparin, three (23%) oral anticoagulant therapy and one continuous IV infusion of heparin. Clinical diagnosis was reached in 6 cases. Excessive activity of anticoagulant therapy was noted in 4 cases. The location of the RSH, their densities and their signals were analysed. All the RSH were mostly developed in the lower third of the abdominal wall, had a large spreading into the Retzius space and compressed the bladder and/or the bowels. RSH were all hyperdense and in 8 cases (61%) a fluid-fluid level due to the hematocrit effect was noted. In one case, a retroperitoneal hematoma was discovered. The extension of the RSH was well delineated with MRI. The RSH showed itself with heterogeneous signal intensities with areas of high-signal-intensity on T1-weighted images. Fluid-fluid levels and a concentric ring sign were also noted. Older women with subcutaneous injection of heparin are especially prone to RSH even though there is no overall excessive activity of anticoagulant therapy. Clinical and biological diagnosis may be difficult. CT scan is the exam of choice to reach a precise and acute diagnosis of RSH. (authors). 34 refs., 8 figs

  11. Molecular Imaging and Updated Diagnostic Criteria in Lewy Body Dementias.

    Science.gov (United States)

    Bohnen, Nicolaas I; Müller, Martijn L T M; Frey, Kirk A

    2017-08-14

    The aims of the study were to review recent advances in molecular imaging in the Lewy body dementias (LBD) and determine if these may support the clinical but contested temporal profile distinction between Parkinson disease (PD) with dementia (PDD) versus dementia with Lewy bodies (DLB). There do not appear to be major regional cerebral metabolic or neurotransmitter distinctions between PDD and DLB. However, recent studies highlight the relative discriminating roles of Alzheimer proteinopathies. PDD patients have lower cortical β-amyloid deposition than DLB. Preliminary tau PET studies suggest a gradient of increasing tau binding from cognitively normal PD (absent to lowest) to cognitively impaired PD (low) to DLB (intermediate) to Alzheimer disease (AD; highest). However, tau binding in DLB, including the medial temporal lobe, is substantially lower than in AD. Alzheimer-type proteinopathies appear to be more common in DLB compared to PDD with relative but no absolute differences. Given the spectrum of overlapping pathologies, future α-synuclein ligands are expected to have the best potential to distinguish the LBD from pure AD.

  12. Modern nuclear cardiac imaging in diagnosis and clinical management of patients with left ventricular dysfunction.

    Science.gov (United States)

    Abidov, A; Hachamovitch, R; Berman, D S

    2004-12-01

    Congestive heart failure (CHF) has become a large social burden in modern Western society, with very high morbidity and mortality and extremely large financial costs. The largest cause of CHF is coronary heart disease, with ventricular dysfunction that may or may not be reversible by revascularization. Thus, evaluation of the viable myocardial tissue in patients with ischemic left ventricular (LV) dysfunction has important clinical and therapeutic implications. Furthermore, since patients with ventricular dysfunction are at higher operative risk, cardiologists and cardiac surgeons are commonly faced with issues regarding the balance between the potential risk vs benefit of revascularization procedures. Cardiac nuclear imaging [myocardial perfusion SPECT (MPS) and positron emission tomography (PET)] provide objective information that augments standard clinical and angiographic assessments of patients with ventricular dysfunction with respect to diagnosis (etiology), prognosis, and potential benefit from intervention. Development of the technology and methodology of gated MPS, now the routine method for MPS, allows assessment of the extent and severity of inducible ischemia as well as hypoperfused but viable myocardium, and also provides measurements of LV ejection fraction, regional wall motion, LV volume measurements, diastolic function and LV geometry. With PET, myocardial metabolism and blood flow reserve can be added to the measurements provided by nuclear cardiology procedures. This paper provides insight into the current evidence regarding settings in which nuclear cardiac imaging procedures are helpful in assessment of patients in the setting of coronary artery disease with severe LV dysfunction. A risk-benefit approach to MPS results is proposed, with principal focus on identifying patients at risk for major cardiac events who may benefit from myocardial revascularization.

  13. Everyone Knows What a Scientist Looks Like: The Image of a Modern Scientist

    Science.gov (United States)

    Enevoldsen, A. A. G.

    2008-11-01

    Children are inspired to follow career paths when they can imagine themselves there. Seeing pictures of adult individuals who look like them working in a given career can provide this spark to children's imaginations. Most (though not all) of the current available posters of scientists are of Einstein, and Einstein-like scientists. This is not representative of the current face of science. To change this, Pacific Science Center will host a photography exhibit: photographs of real, current scientists from all races, genders, beliefs, and walks of life. Photos will be taken and short biographies written by Discovery Corps Interns (Pacific Science Center's youth development program) to increase the amount of direct contact between students and scientists, and to give the exhibit an emotional connection for local teachers and families. We plan to make the photographs from this exhibit available to teachers for use in their classrooms, in addition to being displayed at Pacific Science Center during the International Year of Astronomy. The objectives of this project are to fill a need for representative photographs of scientists in the world community and to meet two of the goals of the International Year of Astronomy: to provide a modern image of science and scientists, and to improve the gender-balanced representation of scientists at all levels and promote greater involvement by under-represented minorities in scientific and engineering careers.

  14. Image-converter diagnostics of laser and laser plasma in pico-femtosecond region

    International Nuclear Information System (INIS)

    Schelev, M.Ya.

    1979-01-01

    In the present communication we would like to outline some new trends in development of pico-femtosecond image-converter diagnostics for laser and laser plasma research on the basis of the recent works done in P.N.Lebedev Physical Institute. The discussion of the following subjects will be included: new generation of picosecond image-converter tubes (ICT), pulsed control circuitry, late prototype of picosecond image-converter cameras (ICC), test installation consisting of Nd: glass and YAG lasers for production the ultra-short pulses and sinusoidally modulated radiation, methods and techniques for image tube and camera dynamic measurements in IR, visible and X-ray spectral regions. Also discussed are the image processing technique for pictures taken with picosecond ICC in order to correct the geometrical distortions, enhance pictures quality and evaluate parameters of the input signals through their recorded images. (author)

  15. Investigation into diagnostic agreement using automated computer-assisted histopathology pattern recognition image analysis

    Directory of Open Access Journals (Sweden)

    Joshua D Webster

    2012-01-01

    Full Text Available The extent to which histopathology pattern recognition image analysis (PRIA agrees with microscopic assessment has not been established. Thus, a commercial PRIA platform was evaluated in two applications using whole-slide images. Substantial agreement, lacking significant constant or proportional errors, between PRIA and manual morphometric image segmentation was obtained for pulmonary metastatic cancer areas (Passing/Bablok regression. Bland-Altman analysis indicated heteroscedastic measurements and tendency toward increasing variance with increasing tumor burden, but no significant trend in mean bias. The average between-methods percent tumor content difference was -0.64. Analysis of between-methods measurement differences relative to the percent tumor magnitude revealed that method disagreement had an impact primarily in the smallest measurements (tumor burden 0.988, indicating high reproducibility for both methods, yet PRIA reproducibility was superior (C.V.: PRIA = 7.4, manual = 17.1. Evaluation of PRIA on morphologically complex teratomas led to diagnostic agreement with pathologist assessments of pluripotency on subsets of teratomas. Accommodation of the diversity of teratoma histologic features frequently resulted in detrimental trade-offs, increasing PRIA error elsewhere in images. PRIA error was nonrandom and influenced by variations in histomorphology. File-size limitations encountered while training algorithms and consequences of spectral image processing dominance contributed to diagnostic inaccuracies experienced for some teratomas. PRIA appeared better suited for tissues with limited phenotypic diversity. Technical improvements may enhance diagnostic agreement, and consistent pathologist input will benefit further development and application of PRIA.

  16. Investigation into diagnostic agreement using automated computer-assisted histopathology pattern recognition image analysis.

    Science.gov (United States)

    Webster, Joshua D; Michalowski, Aleksandra M; Dwyer, Jennifer E; Corps, Kara N; Wei, Bih-Rong; Juopperi, Tarja; Hoover, Shelley B; Simpson, R Mark

    2012-01-01

    The extent to which histopathology pattern recognition image analysis (PRIA) agrees with microscopic assessment has not been established. Thus, a commercial PRIA platform was evaluated in two applications using whole-slide images. Substantial agreement, lacking significant constant or proportional errors, between PRIA and manual morphometric image segmentation was obtained for pulmonary metastatic cancer areas (Passing/Bablok regression). Bland-Altman analysis indicated heteroscedastic measurements and tendency toward increasing variance with increasing tumor burden, but no significant trend in mean bias. The average between-methods percent tumor content difference was -0.64. Analysis of between-methods measurement differences relative to the percent tumor magnitude revealed that method disagreement had an impact primarily in the smallest measurements (tumor burden 0.988, indicating high reproducibility for both methods, yet PRIA reproducibility was superior (C.V.: PRIA = 7.4, manual = 17.1). Evaluation of PRIA on morphologically complex teratomas led to diagnostic agreement with pathologist assessments of pluripotency on subsets of teratomas. Accommodation of the diversity of teratoma histologic features frequently resulted in detrimental trade-offs, increasing PRIA error elsewhere in images. PRIA error was nonrandom and influenced by variations in histomorphology. File-size limitations encountered while training algorithms and consequences of spectral image processing dominance contributed to diagnostic inaccuracies experienced for some teratomas. PRIA appeared better suited for tissues with limited phenotypic diversity. Technical improvements may enhance diagnostic agreement, and consistent pathologist input will benefit further development and application of PRIA.

  17. Diagnostic Method of Diabetes Based on Support Vector Machine and Tongue Images

    Directory of Open Access Journals (Sweden)

    Jianfeng Zhang

    2017-01-01

    Full Text Available Objective. The purpose of this research is to develop a diagnostic method of diabetes based on standardized tongue image using support vector machine (SVM. Methods. Tongue images of 296 diabetic subjects and 531 nondiabetic subjects were collected by the TDA-1 digital tongue instrument. Tongue body and tongue coating were separated by the division-merging method and chrominance-threshold method. With extracted color and texture features of the tongue image as input variables, the diagnostic model of diabetes with SVM was trained. After optimizing the combination of SVM kernel parameters and input variables, the influences of the combinations on the model were analyzed. Results. After normalizing parameters of tongue images, the accuracy rate of diabetes predication was increased from 77.83% to 78.77%. The accuracy rate and area under curve (AUC were not reduced after reducing the dimensions of tongue features with principal component analysis (PCA, while substantially saving the training time. During the training for selecting SVM parameters by genetic algorithm (GA, the accuracy rate of cross-validation was grown from 72% or so to 83.06%. Finally, we compare with several state-of-the-art algorithms, and experimental results show that our algorithm has the best predictive accuracy. Conclusions. The diagnostic method of diabetes on the basis of tongue images in Traditional Chinese Medicine (TCM is of great value, indicating the feasibility of digitalized tongue diagnosis.

  18. Evidence-Centered Design for Diagnostic Assessment within Digital Learning Environments: Integrating Modern Psychometrics and Educational Data Mining

    Science.gov (United States)

    Rupp, André A.; Nugent, Rebecca; Nelson, Brian

    2012-01-01

    In recent years the educational community has increasingly embraced digital technologies for the purposes of developing alternative learning environments, providing diagnostic feedback, and fostering the development of so-called 21st-century skills. This special issue is dedicated to bridging recent work from the disciplines of educational and…

  19. Breast Imaging: How We Manage Diagnostic Technology at a Multidisciplinary Breast Center

    Directory of Open Access Journals (Sweden)

    Alejandro Tejerina Bernal

    2012-01-01

    Full Text Available This paper discusses the most important aspects and problems related to the management of breast cancer imaging, at a center specialized in breast pathology. We review the established and emerging diagnostic techniques, their indications, and peculiarities: digital mammography, CAD systems, and the recent digital breast tomosynthesis, ultrasound and complementary elastography, molecular imaging techniques, magnetic resonance imaging, advanced sequences (diffusion, and positron emission mammography (PEM. The adequate integration and rational management of these techniques is essential, but this is not always easy, in order to achieve a successful diagnosis.

  20. Structured diagnostic imaging in patients with multiple trauma; Strukturierte radiologische Diagnostik beim Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Rieger, J.; Rock, C.; Pfeifer, K.J.; Reiser, M. [Institut fuer Klinische Radiologie, Klinikum der Universitaet Muenchen, Innenstadt (Germany); Kanz, K.G. [Chirurgische Klinik, Klinikum der Universitaet Muenchen, Innenstadt (Germany)

    2002-07-01

    Purpose. Development of a concept for structured diagnostic imaging in patients with multiple trauma.Material and methods. Evaluation of data from a prospective trial with over 2400 documented patients with multiple trauma. All diagnostic and therapeutic steps, primary and secondary death and the 90 days lethality were documented.Structured diagnostic imaging of multiple injured patients requires the integration of an experienced radiologist in an interdisciplinary trauma team consisting of anesthesia, radiology and trauma surgery. Radiology itself deserves standardized concepts for equipment, personnel and logistics to perform diagnostic imaging for a 24-h-coverage with constant quality.Results. This paper describes criteria for initiation of a shock room or emergency room treatment, strategies for documentation and interdisciplinary algorithms for the early clinical care coordinating diagnostic imaging and therapeutic procedures following standardized guidelines. Diagnostic imaging consists of basic diagnosis, radiological ABC-rule, radiological follow-up and structured organ diagnosis using CT. Radiological trauma scoring allows improved quality control of diagnosis and therapy of multiple injured patients.Conclusion. Structured diagnostic imaging of multiple injured patients leads to a standardization of diagnosis and therapy and ensures constant process quality. (orig.) [German] Fragestellung. Entwicklung eines strukturierten Konzeptes zur radiologischen Diagnostik polytraumatisierter Patienten.Methodik. Die Datenevaluation erfolgte auf Basis einer prospektiven interdisziplinaere Polytraumastudie mit ueber 2400 Patienten. Alle diagnostischen und therapeutischen Schritte werden jeweils unter Angabe von Zeitpunkt und auftretenden Komplikationen erfasst, ein primaeres oder sekundaeres Versterben und die 90-Tage-Letalitaet werden dokumentiert.Die strukturierte radiologische Diagnostik von Mehrfachverletzen verlangt die Integration eines erfahrenen Radiologen in

  1. Innovation in diagnostic imaging services: assessing the potential for value-based reimbursement.

    Science.gov (United States)

    Garrison, Louis P; Bresnahan, Brian W; Higashi, Mitchell K; Hollingworth, William; Jarvik, Jeffrey G

    2011-09-01

    Innovation in the field of diagnostic imaging is based primarily on the availability of new and improved equipment that opens the door for new clinical applications. Payments for these imaging procedures are subject to complex Medicare price control schemes, affecting incentives for appropriate use and innovation. Achieving a "dynamically efficient" health care system-one that elicits a socially optimal amount of innovation-requires that innovators be rewarded in relation to the value they add and can demonstrate with evidence. The authors examine how and whether value-based reimbursement for diagnostic imaging services might better reward innovation explicitly for expected improvements in health and economic outcomes. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  2. Diagnostic imaging of the equine tarsal region using radiography and ultrasonography. Part 1: the soft tissues.

    Science.gov (United States)

    Vanderperren, Katrien; Raes, Els; Hoegaerts, Michel; Saunders, Jimmy H

    2009-02-01

    The equine tarsus is the most commonly affected hindlimb region associated with lameness. Diagnostic imaging is routinely applied but because of its complexity, being composed of 10 multifaceted bones and different joints, multiple ligaments, tendons and bursae, imaging this region can be a challenge. This is the first part of a two-part review of the structures and disorders of the equine tarsus. It describes the principal disorders affecting the soft tissues of the tarsal region and addresses some of the technical aspects in taking radiographic, ultrasonographic and scintigraphic images of the different soft tissue lesions. Where applicable, comments on the diagnostic use of contrast radiography, arthroscopy and tenoscopy are made. In current clinical practice a combination of radiography and ultrasonography is still most frequently used to arrive at a diagnosis.

  3. Magnetic resonance imaging for diagnostic evaluation of hernia of an invertebral disk

    International Nuclear Information System (INIS)

    Beyer, H.K.; Oppel, G.; Bluemm, R.; Uhlenbrock, D.

    1988-01-01

    The article reports experience gained within three years with diagnostic NMR imaging of the lumbar spine. On the basis of results obtained by almost 500 examinations, an optimisation concept with regard to measuring sequences and orientation of sectional cuts is presented. Imaging of the spine in three planes, with sectional layer thickness between 3 and 5 mm, using a 1.5 Tesla system, seems to yield the diagnostic optimum, and in our opinion is superior over invasive myelography and CT scanning. A prospective study we made indicates a hit rate of 97.2%, and of 100% for evaluation of the results obtained with the 1.5 Tesla system together with an evaluation of the paraxial sections. The magnetic field intensity of 1.5 Tesla especially improves the quality of images of paraxial cuts as compared with the 0.5 Tesla field system, due to the better contrast-to-noise ratio, and thinner sections. (orig.) [de

  4. First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

    Energy Technology Data Exchange (ETDEWEB)

    Rosch, R.; Trosseille, C.; Caillaud, T.; Allouche, V.; Bourgade, J. L.; Briat, M.; Brunel, P.; Burillo, M.; Casner, A.; Depierreux, S.; Gontier, D.; Jadaud, J. P.; Le Breton, J. P.; Llavador, P.; Loupias, B.; Miquel, J. L.; Oudot, G.; Perez, S.; Raimbourg, J.; Rousseau, A. [CEA-DAM Ile de France, Bruyères-le-Châtel, 91297 Arpajon Cedex (France); and others

    2016-03-15

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

  5. Automatic volumetry on MR brain images can support diagnostic decision making

    Directory of Open Access Journals (Sweden)

    Aviv Richard I

    2008-05-01

    Full Text Available Abstract Background Diagnostic decisions in clinical imaging currently rely almost exclusively on visual image interpretation. This can lead to uncertainty, for example in dementia disease, where some of the changes resemble those of normal ageing. We hypothesized that extracting volumetric data from patients' MR brain images, relating them to reference data and presenting the results as a colour overlay on the grey scale data would aid diagnostic readers in classifying dementia disease versus normal ageing. Methods A proof-of-concept forced-choice reader study was designed using MR brain images from 36 subjects. Images were segmented into 43 regions using an automatic atlas registration-based label propagation procedure. Seven subjects had clinically probable AD, the remaining 29 of a similar age range were used as controls. Seven of the control subject data sets were selected at random to be presented along with the seven AD datasets to two readers, who were blinded to all clinical and demographic information except age and gender. Readers were asked to review the grey scale MR images and to record their choice of diagnosis (AD or non-AD along with their confidence in this decision. Afterwards, readers were given the option to switch on a false-colour overlay representing the relative size of the segmented structures. Colorization was based on the size rank of the test subject when compared with a reference group consisting of the 22 control subjects who were not used as review subjects. The readers were then asked to record whether and how the additional information had an impact on their diagnostic confidence. Results The size rank colour overlays were useful in 18 of 28 diagnoses, as determined by their impact on readers' diagnostic confidence. A not useful result was found in 6 of 28 cases. The impact of the additional information on diagnostic confidence was significant (p Conclusion Volumetric anatomical information extracted from brain

  6. Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Y. L.; Xie, J. L., E-mail: jlxie@ustc.edu.cn; Yu, C. X.; Zhao, Z. L.; Gao, B. X.; Chen, D. X.; Liu, W. D.; Liao, W.; Qu, C. M.; Luo, C. [School of Physics, University of Science and Technology of China, Anhui 230026 (China); Hu, X.; Spear, A. G.; Luhmann, N. C.; Domier, C. W.; Chen, M.; Ren, X. [University of California, Davis, California 95616 (United States); Tobias, B. J. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-11-15

    Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.

  7. Imaging of chest trauma: radiological patterns of injury and diagnostic algorithms

    International Nuclear Information System (INIS)

    Lomoschitz, Fritz M.; Eisenhuber, Edith; Linnau, Ken F.; Peloschek, Philipp; Schoder, Maria; Bankier, Alexander A.

    2003-01-01

    In patients after chest trauma, imaging plays a key role for both, the primary diagnostic work-up, and the secondary assessment of potential treatment. Despite its well-known limitations, the anteroposterior chest radiograph remains the starting point of the imaging work-up. Adjunctive imaging with computed tomography, that recently is increasingly often performed on multidetector computed tomography units, adds essential information not readily available on the conventional radiograph. This allows better definition of trauma-associated thoracic injuries not only in acute traumatic aortic injury, but also in pulmonary, tracheobronchial, cardiac, diaphragmal, and thoracic skeletal injuries. This article reviews common radiographic findings in patients after chest trauma, shows typical imaging features resulting from thoracic injury, presents imaging algorithms, and recalls to the reader less common but clinically relevant entities encountered in patients after thoracic trauma

  8. Between history, criticism, and wit: texts and images of English modern architecture (1933-36

    Directory of Open Access Journals (Sweden)

    Michela Rosso

    2016-06-01

    Full Text Available It has often been remarked that modern architecture in Britain began late and that its emergence largely depended on the contribution of a massive influx of European exiles seeking refuge from the political and racial persecution of totalitarian regimes. In the attempt to discard the tired narrative of Britain’s insular modernism as a mere echo of continental European achievements, an alternative historiography has recently directed attention to Britain’s own distinctive and original version of modern architecture in the 1930s. Through the examination of a small group of articles, books and pamphlets on English modern architecture written by English authors and published in the mid-1930s, this paper argues that the emergence of a distinctive version of architectural modernism in Britain was paralleled by the development of an equally original brand of architectural criticism and historiography.

  9. Metadata requirements for results of diagnostic imaging procedures: a BIIF profile to support user applications

    Science.gov (United States)

    Brown, Nicholas J.; Lloyd, David S.; Reynolds, Melvin I.; Plummer, David L.

    2002-05-01

    A visible digital image is rendered from a set of digital image data. Medical digital image data can be stored as either: (a) pre-rendered format, corresponding to a photographic print, or (b) un-rendered format, corresponding to a photographic negative. The appropriate image data storage format and associated header data (metadata) required by a user of the results of a diagnostic procedure recorded electronically depends on the task(s) to be performed. The DICOM standard provides a rich set of metadata that supports the needs of complex applications. Many end user applications, such as simple report text viewing and display of a selected image, are not so demanding and generic image formats such as JPEG are sometimes used. However, these are lacking some basic identification requirements. In this paper we make specific proposals for minimal extensions to generic image metadata of value in various domains, which enable safe use in the case of two simple healthcare end user scenarios: (a) viewing of text and a selected JPEG image activated by a hyperlink and (b) viewing of one or more JPEG images together with superimposed text and graphics annotation using a file specified by a profile of the ISO/IEC Basic Image Interchange Format (BIIF).

  10. Confirmation of Thermal Images and Vibration Signals for Intelligent Machine Fault Diagnostics

    Directory of Open Access Journals (Sweden)

    Achmad Widodo

    2012-01-01

    Full Text Available This paper deals with the maintenance technique for industrial machinery using the artificial neural network so-called self-organizing map (SOM. The aim of this work is to develop intelligent maintenance system for machinery based on an alternative way, namely, thermal images instead of vibration signals. SOM is selected due to its simplicity and is categorized as an unsupervised algorithm. Following the SOM training, machine fault diagnostics is performed by using the pattern recognition technique of machine conditions. The data used in this work are thermal images and vibration signals, which were acquired from machine fault simulator (MFS. It is a reliable tool and is able to simulate several conditions of faulty machine such as unbalance, misalignment, looseness, and rolling element bearing faults (outer race, inner race, ball, and cage defects. Data acquisition were conducted simultaneously by infrared thermography camera and vibration sensors installed in the MFS. The experimental data are presented as thermal image and vibration signal in the time domain. Feature extraction was carried out to obtain salient features sensitive to machine conditions from thermal images and vibration signals. These features are then used to train the SOM for intelligent machine diagnostics process. The results show that SOM can perform intelligent fault diagnostics with plausible accuracies.

  11. OpenID connect as a security service in Cloud-based diagnostic imaging systems

    Science.gov (United States)

    Ma, Weina; Sartipi, Kamran; Sharghi, Hassan; Koff, David; Bak, Peter

    2015-03-01

    The evolution of cloud computing is driving the next generation of diagnostic imaging (DI) systems. Cloud-based DI systems are able to deliver better services to patients without constraining to their own physical facilities. However, privacy and security concerns have been consistently regarded as the major obstacle for adoption of cloud computing by healthcare domains. Furthermore, traditional computing models and interfaces employed by DI systems are not ready for accessing diagnostic images through mobile devices. RESTful is an ideal technology for provisioning both mobile services and cloud computing. OpenID Connect, combining OpenID and OAuth together, is an emerging REST-based federated identity solution. It is one of the most perspective open standards to potentially become the de-facto standard for securing cloud computing and mobile applications, which has ever been regarded as "Kerberos of Cloud". We introduce OpenID Connect as an identity and authentication service in cloud-based DI systems and propose enhancements that allow for incorporating this technology within distributed enterprise environment. The objective of this study is to offer solutions for secure radiology image sharing among DI-r (Diagnostic Imaging Repository) and heterogeneous PACS (Picture Archiving and Communication Systems) as well as mobile clients in the cloud ecosystem. Through using OpenID Connect as an open-source identity and authentication service, deploying DI-r and PACS to private or community clouds should obtain equivalent security level to traditional computing model.

  12. [Handling modern imaging procedures in a high-tech operating room].

    Science.gov (United States)

    Hüfner, T; Citak, M; Imrecke, J; Krettek, C; Stübig, T

    2012-03-01

    Operating rooms are the central unit in the hospital network in trauma centers. In this area, high costs but also high revenues are generated. Modern operating theater concepts as an integrated model have been offered by different companies since the early 2000s. Our hypothesis is that integrative concepts for operating rooms, in addition to improved operating room ergonomics, have the potential for measurable time and cost savings. In our clinic, an integrated operating room concept (I-Suite, Stryker, Duisburg) was implemented after analysis of the problems. In addition to the ceiling-mounted arrangement, the system includes an endoscopy unit, a navigation system, and a voice control system. In the first 6 months (9/2005 to 2/2006), 112 procedures were performed in the integrated operating room: 34 total knee arthroplasties, 12 endoscopic spine surgeries, and 66 inpatient arthroscopic procedures (28 shoulder and 38 knee reconstructions). The analysis showed a daily saving of 22-45 min, corresponding to 15-30% of the daily changeover times, calculated to account for potential savings in the internal cost allocation of 225-450 EUR. A commercial operating room concept was evaluated in a pilot phase in terms of hard data, including time and cost factors. Besides the described effects further savings might be achieved through the effective use of voice control and the benefit of the sterile handle on the navigation camera, since waiting times for an additional nurse are minimized. The time of the procedure of intraoperative imaging is also reduced due to the ceiling-mounted concept, as the C-arm can be moved freely in the operating theater without hindering cables. By these measures and ensuing improved efficiency, the initial high costs for the implementation of the system may be cushioned over time.

  13. Distributed decision making in action: diagnostic imaging investigations within the bigger picture.

    Science.gov (United States)

    Makanjee, Chandra R; Bergh, Anne-Marie; Hoffmann, Willem A

    2018-03-01

    Decision making in the health care system - specifically with regard to diagnostic imaging investigations - occurs at multiple levels. Professional role players from various backgrounds are involved in making these decisions, from the point of referral to the outcomes of the imaging investigation. The aim of this study was to map the decision-making processes and pathways involved when patients are referred for diagnostic imaging investigations and to explore distributed decision-making events at the points of contact with patients within a health care system. A two-phased qualitative study was conducted in an academic public health complex with the district hospital as entry point. The first phase included case studies of 24 conveniently selected patients, and the second phase involved 12 focus group interviews with health care providers. Data analysis was based on Rapley's interpretation of decision making as being distributed across time, situations and actions, and including different role players and technologies. Clinical decisions incorporating imaging investigations are distributed across the three vital points of contact or decision-making events, namely the initial patient consultation, the diagnostic imaging investigation and the post-investigation consultation. Each of these decision-making events is made up of a sequence of discrete decision-making moments based on the transfer of retrospective, current and prospective information and its transformation into knowledge. This paper contributes to the understanding of the microstructural processes (the 'when' and 'where') involved in the distribution of decisions related to imaging investigations. It also highlights the interdependency in decision-making events of medical and non-medical providers within a single medical encounter. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation

  14. MALDI TOF imaging mass spectrometry in clinical pathology: a valuable tool for cancer diagnostics (review).

    Science.gov (United States)

    Kriegsmann, Jörg; Kriegsmann, Mark; Casadonte, Rita

    2015-03-01

    Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) imaging mass spectrometry (IMS) is an evolving technique in cancer diagnostics and combines the advantages of mass spectrometry (proteomics), detection of numerous molecules, and spatial resolution in histological tissue sections and cytological preparations. This method allows the detection of proteins, peptides, lipids, carbohydrates or glycoconjugates and small molecules.Formalin-fixed paraffin-embedded tissue can also be investigated by IMS, thus, this method seems to be an ideal tool for cancer diagnostics and biomarker discovery. It may add information to the identification of tumor margins and tumor heterogeneity. The technique allows tumor typing, especially identification of the tumor of origin in metastatic tissue, as well as grading and may provide prognostic information. IMS is a valuable method for the identification of biomarkers and can complement histology, immunohistology and molecular pathology in various fields of histopathological diagnostics, especially with regard to identification and grading of tumors.

  15. Diagnostic imaging of the hand. 3. rev. and enl. ed.; Bildgebende Diagnostik der Hand

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Rainer [Herz und Gefaessklinik GmbH, Bad Neustadt (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Lanz, Ulrich

    2015-07-01

    The book on diagnostic imaging of the hand covers the following issues: projection radiography, cinematography, MRT and CR arthrography, arthroscopy, arteriography, skeleton scintiscanning, sonography, computerized tomography, magnetic resonance tomography, anatomy of forearm and carpus, anatomy of metacarpus and fingers, carpal function and morphometry, postoperative X-ray diagnostic, growing hand skeleton, normative variants, malformations and deformities, trauma of the distal forearm, lesions of the ulnocarpal complex (TFCC), scaphoid fractures, scaphoid arthrosis, fractures of other carpus bones, carpal luxations and luxation fractures, carpal instabilities, fractures of the metacarpalla, finger fractures, arthrosis deformans, enthesiopathies, sport induced soft tissue lesions, osteonecrosis, impingement syndromes, osteopenic skeletal diseases, metabolis diseases, crystal-induced osteoarthropaties, rheumatoid arthritis, spondyloarthritis, rheumatic fever, collagenoses, infective arthritis, osteomyelitis, soft tissue infections, cystoids bone lesions, skeletal tumors, soft tissue tumors, carpal tunnel syndrome, nerve compression syndrome, arterial perfusion disturbances, differential diagnostic tables on hand lesions.

  16. Interferometric Reflectance Imaging Sensor (IRIS—A Platform Technology for Multiplexed Diagnostics and Digital Detection

    Directory of Open Access Journals (Sweden)

    Oguzhan Avci

    2015-07-01

    Full Text Available Over the last decade, the growing need in disease diagnostics has stimulated rapid development of new technologies with unprecedented capabilities. Recent emerging infectious diseases and epidemics have revealed the shortcomings of existing diagnostics tools, and the necessity for further improvements. Optical biosensors can lay the foundations for future generation diagnostics by providing means to detect biomarkers in a highly sensitive, specific, quantitative and multiplexed fashion. Here, we review an optical sensing technology, Interferometric Reflectance Imaging Sensor (IRIS, and the relevant features of this multifunctional platform for quantitative, label-free and dynamic detection. We discuss two distinct modalities for IRIS: (i low-magnification (ensemble biomolecular mass measurements and (ii high-magnification (digital detection of individual nanoparticles along with their applications, including label-free detection of multiplexed protein chips, measurement of single nucleotide polymorphism, quantification of transcription factor DNA binding, and high sensitivity digital sensing and characterization of nanoparticles and viruses.

  17. Lunar archive panoramas: modern image processing and access to the historic data based on spatial context

    Science.gov (United States)

    Kozlova, Natalia; Kokhanov, Alexander; Oberst, Jürgen; Zubarev, Anatoliy; Nadezhdina, Irina; Patraty, Vyacheslav; Karachevtseva, Irina; Garov, Andrey; Matveev, Evgeniy

    The objectives of our work are to fully exploit the historic Soviet Lunokhod data and use the results for scientific and public purposes. Unfortunately, many of the relevant operational parameters of the Lunokhods missions are lost. Modern photogrammetry is a key to solving these issues, providing analysis techniques, not available at the time of the early lunar missions. For this purpose we use special developed software, GIS tools and high-resolution LRO data [1]. Results of new image processing of historic data are part of PRoViDE project (Planetary Robotics Vision Data Exploitation) which aims to assemble a major portion of the imaging data gathered from different vehicles and probes on planetary surfaces into a unique database, bringing them into a spatial context and providing access to a complete set of 3D vision products (http://www.provide-space.eu/). Our technology of archive panorama processing allows us to recover lost information of Soviet lunar missions and study lunar landing site imagery by state-of-the-art photogrammetric techniques. Our main task is to perform lunar panoramas in measurement form based on photogrammetry and geoanalyses methods, and then involve them in more detailed morphometric analyses [2] and 3D-modeling of lunar surface based on LROC NAC image processing [3]. The results of our work are various types of new products: panoramas in different projections, updated metadata with recovering parameters, and ortho-panoramas, which can be used for quantitative geomorphology assessment based on spatial tools [4]. All data products obtained as a result of the study are to be placed into Planetary data storage which is developing as Geodesy and Cartography Node [5]. Access to archive lunar data will be organized via Geo-portal (http://cartsrv.mexlab.ru/geoportal/) using authorization service, which provided data security and user control. Planetary spatial information system can integrate various types of data for planets and their

  18. Glioblastomas vs. lymphomas. More diagnostic certainty by using susceptibility-weighted imaging (SWI)

    Energy Technology Data Exchange (ETDEWEB)

    Peters, S.; Knoess, N.; Wodarg, F.; Cnyrim, C.; Jansen, O. [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Inst. fuer Neuroradiologie

    2012-08-15

    Purpose: It can be difficult to differentiate glioblastomas from lymphomas using only standard MR images. There are references suggesting that it might be possible to differentiate these tumors using susceptibility-weighted imaging (SWI). The purpose of this study is to prove the diagnostic benefit using susceptibility-weighted images. Material and Methods: Three neuroradiologists tried to differentiate 4 histologically verified lymphomas from 11 glioblastomas in retrospect. They first viewed the conventional MR images and declared a diagnosis with a grade of certainty. Afterwards they additionally reviewed the susceptibility-weighted images. Results: Glioblastomas have a clearly higher grade of susceptibility signals than lymphomas. By additionally using susceptibility-weighted images, the radiologists determined the correct diagnosis in 82.2 % of the cases. Without susceptibility-weighted images, the diagnosis was correct in 75.5 % of the cases. The subjective gain of certainty was 16.5 %. If there were no intratumoral susceptibility signals (ITSS) (grade 1), the sensitivity for diagnosing a lymphoma was 70 % and the specificity was 100 %. The sensitivity for diagnosing a glioblastoma was 90.5 % and the specificity was 100 % if there was a high rate of intratumoral susceptibility signals (grade 3). Conclusion: Susceptibility-weighted images are an additional tool in clinical practice for determining the correct diagnosis. The differentiation between glioblastomas and lymphomas and the certainty of the determined diagnosis are better. Therefore, we recommend adding susceptibility-weighted imaging to the clinical MR tumor protocol. (orig.)

  19. Glioblastomas vs. lymphomas: more diagnostic certainty by using susceptibility-weighted imaging (SWI).

    Science.gov (United States)

    Peters, S; Knöß, N; Wodarg, F; Cnyrim, C; Jansen, O

    2012-08-01

    It can be difficult to differentiate glioblastomas from lymphomas using only standard MR images. There are references suggesting that it might be possible to differentiate these tumors using susceptibility-weighted imaging (SWI). The purpose of this study is to prove the diagnostic benefit using susceptibility-weighted images. Three neuroradiologists tried to differentiate 4 histologically verified lymphomas from 11 glioblastomas in retrospect. They first viewed the conventional MR images and declared a diagnosis with a grade of certainty. Afterwards they additionally reviewed the susceptibility-weighted images. Glioblastomas have a clearly higher grade of susceptibility signals than lymphomas. By additionally using susceptibility-weighted images, the radiologists determined the correct diagnosis in 82.2 % of the cases. Without susceptibility-weighted images, the diagnosis was correct in 75.5 % of the cases. The subjective gain of certainty was 16.5 %. If there were no intratumoral susceptibility signals (ITSS) (grade 1), the sensitivity for diagnosing a lymphoma was 70 % and the specificity was 100 %. The sensitivity for diagnosing a glioblastoma was 90.5 % and the specificity was 100 % if there was a high rate of intratumoral susceptibility signals (grade 3). Susceptibility-weighted images are an additional tool in clinical practice for determining the correct diagnosis. The differentiation between glioblastomas and lymphomas and the certainty of the determined diagnosis are better. Therefore, we recommend adding susceptibility-weighted imaging to the clinical MR tumor protocol. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Glioblastomas vs. lymphomas. More diagnostic certainty by using susceptibility-weighted imaging (SWI)

    International Nuclear Information System (INIS)

    Peters, S.; Knoess, N.; Wodarg, F.; Cnyrim, C.; Jansen, O.

    2012-01-01

    Purpose: It can be difficult to differentiate glioblastomas from lymphomas using only standard MR images. There are references suggesting that it might be possible to differentiate these tumors using susceptibility-weighted imaging (SWI). The purpose of this study is to prove the diagnostic benefit using susceptibility-weighted images. Material and Methods: Three neuroradiologists tried to differentiate 4 histologically verified lymphomas from 11 glioblastomas in retrospect. They first viewed the conventional MR images and declared a diagnosis with a grade of certainty. Afterwards they additionally reviewed the susceptibility-weighted images. Results: Glioblastomas have a clearly higher grade of susceptibility signals than lymphomas. By additionally using susceptibility-weighted images, the radiologists determined the correct diagnosis in 82.2 % of the cases. Without susceptibility-weighted images, the diagnosis was correct in 75.5 % of the cases. The subjective gain of certainty was 16.5 %. If there were no intratumoral susceptibility signals (ITSS) (grade 1), the sensitivity for diagnosing a lymphoma was 70 % and the specificity was 100 %. The sensitivity for diagnosing a glioblastoma was 90.5 % and the specificity was 100 % if there was a high rate of intratumoral susceptibility signals (grade 3). Conclusion: Susceptibility-weighted images are an additional tool in clinical practice for determining the correct diagnosis. The differentiation between glioblastomas and lymphomas and the certainty of the determined diagnosis are better. Therefore, we recommend adding susceptibility-weighted imaging to the clinical MR tumor protocol. (orig.)

  1. Diesel combustion and emissions formation using multiple 2-D imaging diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dec, J.E. [Sandia National Labs., Livermore, CA (United States)

    1997-12-31

    Understanding how emissions are formed during diesel combustion is central to developing new engines that can comply with increasingly stringent emission standards while maintaining or improving performance levels. Laser-based planar imaging diagnostics are uniquely capable of providing the temporally and spatially resolved information required for this understanding. Using an optically accessible research engine, a variety of two-dimensional (2-D) imaging diagnostics have been applied to investigators of direct-injection (DI) diesel combustion and emissions formation. These optical measurements have included the following laser-sheet imaging data: Mie scattering to determine liquid-phase fuel distributions, Rayleigh scattering for quantitative vapor-phase-fuel/air mixture images, laser induced incandescence (LII) for relative soot concentrations, simultaneous LII and Rayleigh scattering for relative soot particle-size distributions, planar laser-induced fluorescence (PLIF) to obtain early PAH (polyaromatic hydrocarbon) distributions, PLIF images of the OH radical that show the diffusion flame structure, and PLIF images of the NO radical showing the onset of NO{sub x} production. In addition, natural-emission chemiluminescence images were obtained to investigate autoignition. The experimental setup is described, and the image data showing the most relevant results are presented. Then the conceptual model of diesel combustion is summarized in a series of idealized schematics depicting the temporal and spatial evolution of a reacting diesel fuel jet during the time period investigated. Finally, recent PLIF images of the NO distribution are presented and shown to support the timing and location of NO formation hypothesized from the conceptual model.

  2. Imaging and diagnostic criteria for multiple sclerosis: are we there yet?

    International Nuclear Information System (INIS)

    Josey, Lawrence; Curley, Michael; Mousavi, Foroogh Jafari; Taylor, Bruce V.; Lucas, Robyn; Coulthard, Alan

    2012-01-01

    Excluding post traumatic injury, Multiple Sclerosis (MS) is the most common disabling neurological disorder of young adults. Although the effect on mortality is limited, the association of a young demographic and significant morbidity combine to make MS a devastating disease. Since MS was given its first detailed description in 1868, diagnostic criteria continue to evolve. Recently, there has been an international commitment to combine both clinical and paraclinical tests to arrive at an earlier diagnosis. Widespread acceptance of the use of MRI in diagnosis, monitoring and research has made the role of the radiologist more critical than ever in this disease. The primary diagnostic criteria for MS are the International Panel criteria, commonly referred to as the McDonald criteria and it is essential that the radiology community is aware of the work preceding these criteria, so that they are understood in the correct context and the importance acknowledged. Literature review utilising key word search to obtain the historical and current context of magnetic resonance imaging in the diagnosis of MS. A succinct description of the evolution of criteria for the diagnosis of MS. Radiologists must recognise that there are specific diagnostic criteria for MS that continue to evolve as a result of new research, improved technology and clinical experience and it is crucial that these criteria be applied in daily practice. It should be evident that diagnostic imaging criteria for MS will be most effective when combined with standardised MRI protocols such as those published by the international Consortium of Multiple Sclerosis Centres.

  3. Detection rates in pediatric diagnostic imaging: a picture archive and communication system compared with a web-based imaging system

    International Nuclear Information System (INIS)

    McDonald, L.; Cramer, B.; Barrett, B.

    2006-01-01

    This prospective study assesses whether there are differences in accuracy of interpretation of diagnostic images among users of a picture archive and communication system (PACS) diagnostic workstation, compared with a less costly Web-based imaging system on a personal computer (PC) with a high resolution monitor. One hundred consecutive pediatric chest or abdomen and skeletal X-rays were selected from hospital inpatient and outpatient studies over a 5-month interval. They were classified as normal (n = 32), obviously abnormal (n = 33), or having subtle abnormal findings (n = 35) by 2 senior radiologists who reached a consensus for each individual case. Subsequently, 5 raters with varying degrees of experience independently viewed and interpreted the cases as normal or abnormal. Raters viewed each image 1 month apart on a PACS and on the Web-based PC imaging system. There was no relation between accuracy of detection and the system used to evaluate X-ray images (P = 0.92). The total percentage of incorrect interpretations on the Web-based PC imaging system was 23.2%, compared with 23.6% on the PACS (P = 0.92). For all raters combined, the overall difference in proportion assessed incorrectly on the PACS, compared with the PC system, was not significant at 0.4% (95%CI, -3.5% to 4.3%). The high-resolution Web-based imaging system via PC is an adequate alternative to a PACS clinical workstation. Accordingly, the provision of a more extensive network of workstations throughout the hospital setting could have potentially significant cost savings. (author)

  4. An investigation of infection control for x-ray cassettes in a diagnostic imaging department

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Matthew [School of Allied Health Professions and Science, Faculty of Health, Wellbeing and Science, University Campus Suffolk, Rope Walk, Ipswich, Suffolk, IP4 1LT (United Kingdom); Harvey, Jane M. [School of Allied Health Professions and Science, Faculty of Health, Wellbeing and Science, University Campus Suffolk, Rope Walk, Ipswich, Suffolk, IP4 1LT (United Kingdom)], E-mail: j.harvey@ucs.ac.uk

    2008-11-15

    Introduction: This research was conducted to investigate if X-ray cassettes could be a possible source of pathogens capable of causing nosocomial infections, and if they could be a possible vector for cross infection within the hospital environment. Method: The research involved the swabbing of X-ray cassettes in a Diagnostic Imaging Department of a large hospital in the east of England. Two areas of the Diagnostic Imaging Department were included in the study. Research concentrated on X-ray cassettes used for mobile radiography, accident and emergency and inpatient use. Forty cassettes were swabbed in total specifically for general levels of bacterial contamination, also for the presence or absence of methicillin-resistant Staphylococcus aureus (MRSA). A mapping exercise was completed following the location of an X-ray cassette typically used in mobile radiography. The exercise noted the level of direct contact with patient's skin and other possible routes of infection. Results: The results demonstrated that there were large levels of growth of samples taken from cassettes and developed in the Microbiology Department. Coagulase-negative Staphylococcus, Micrococci, Diptheroids and species of Bacillus were all identified. The mapping exercise in which the journey of a 35/43 cm cassette used for mobile radiography was tracked found that contact with patient's skin and potential pathogens or routes of cross infection was a common occurrence whilst undertaking mobile radiography. Conclusion: The research has identified the presence of bacterial contamination on cassettes. The research established that X-ray cassettes/imaging plates are often exposed to pathogens and possible routes of cross infection; also that patient's skin often comes directly in contact with the X-ray cassette/imaging plate. The research also shows that as cassettes/imaging plates are a potential source of cross infection, the Diagnostic Imaging Department may be partly responsible

  5. An investigation of infection control for x-ray cassettes in a diagnostic imaging department

    International Nuclear Information System (INIS)

    Fox, Matthew; Harvey, Jane M.

    2008-01-01

    Introduction: This research was conducted to investigate if X-ray cassettes could be a possible source of pathogens capable of causing nosocomial infections, and if they could be a possible vector for cross infection within the hospital environment. Method: The research involved the swabbing of X-ray cassettes in a Diagnostic Imaging Department of a large hospital in the east of England. Two areas of the Diagnostic Imaging Department were included in the study. Research concentrated on X-ray cassettes used for mobile radiography, accident and emergency and inpatient use. Forty cassettes were swabbed in total specifically for general levels of bacterial contamination, also for the presence or absence of methicillin-resistant Staphylococcus aureus (MRSA). A mapping exercise was completed following the location of an X-ray cassette typically used in mobile radiography. The exercise noted the level of direct contact with patient's skin and other possible routes of infection. Results: The results demonstrated that there were large levels of growth of samples taken from cassettes and developed in the Microbiology Department. Coagulase-negative Staphylococcus, Micrococci, Diptheroids and species of Bacillus were all identified. The mapping exercise in which the journey of a 35/43 cm cassette used for mobile radiography was tracked found that contact with patient's skin and potential pathogens or routes of cross infection was a common occurrence whilst undertaking mobile radiography. Conclusion: The research has identified the presence of bacterial contamination on cassettes. The research established that X-ray cassettes/imaging plates are often exposed to pathogens and possible routes of cross infection; also that patient's skin often comes directly in contact with the X-ray cassette/imaging plate. The research also shows that as cassettes/imaging plates are a potential source of cross infection, the Diagnostic Imaging Department may be partly responsible for adding to

  6. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  7. Additive diagnostic role of imaging in glaucoma: optical coherence tomography and retinal nerve fiber layer photography.

    Science.gov (United States)

    Kim, Ko Eun; Kim, Seok Hwan; Oh, Sohee; Jeoung, Jin Wook; Suh, Min Hee; Seo, Je Hyun; Kim, Martha; Park, Ki Ho; Kim, Dong Myung

    2014-11-20

    To investigate the additive diagnostic role of spectral-domain optical coherence tomography (SD-OCT) and red-free retinal nerve fiber layer photography (RNFLP) in making clinical glaucoma diagnosis. Four diagnostic combination sets, including the most recent image from each measurement of 196 glaucoma eyes (including the 44 preperimetric glaucoma eyes) and 101 healthy eyes, were prepared: (1) stereo disc photography and Humphrey visual field (SH), (2) SH and SD-OCT (SHO), (3) SH and RNFLP (SHR), and (4) SHR and SD-OCT (SHRO). Each randomly sorted set was serially presented at 1-month intervals to five glaucoma specialists who were asked to evaluate them in a subjective and independent manner. The specialists' glaucoma-diagnostic performances based on the sets were then compared. For each specialist, adding SD-OCT to SH or SHR increased the glaucoma-diagnostic sensitivity but not to a level of statistical significance. For one specialist, adding RNFLP to SH significantly increased the sensitivity. Each specialist showed a high level of specificity regardless of the diagnostic set. The overall sensitivity of all specialists' assessments was significantly increased by adding RNFLP or the combination of SD-OCT and RNFLP to SH (P < 0.001); however, adding SD-OCT to SH or SHR did not significantly increase the sensitivity. A similar relationship was noted also for the preperimetric glaucoma subgroup. In contrast to RNFLP, SD-OCT did not significantly enhance the diagnostic accuracy of detecting glaucoma or even of preperimetric glaucoma. Our results suggest that, at least for glaucoma specialists, the additive diagnostic role of OCT is limited. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  8. How doctors generate diagnostic hypotheses: a study of radiological diagnosis with functional magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Marcio Melo

    Full Text Available In medical practice, diagnostic hypotheses are often made by physicians in the first moments of contact with patients; sometimes even before they report their symptoms. We propose that generation of diagnostic hypotheses in this context is the result of cognitive processes subserved by brain mechanisms that are similar to those involved in naming objects or concepts in everyday life.To test this proposal we developed an experimental paradigm with functional magnetic resonance imaging (fMRI using radiological diagnosis as a model. Twenty-five radiologists diagnosed lesions in chest X-ray images and named non-medical targets (animals embedded in chest X-ray images while being scanned in a fMRI session. Images were presented for 1.5 seconds; response times (RTs and the ensuing cortical activations were assessed. The mean response time for diagnosing lesions was 1.33 (SD ±0.14 seconds and 1.23 (SD ±0.13 seconds for naming animals. 72% of the radiologists reported cogitating differential diagnoses during trials (3.5 seconds. The overall pattern of cortical activations was remarkably similar for both types of targets. However, within the neural systems shared by both stimuli, activation was significantly greater in left inferior frontal sulcus and posterior cingulate cortex for lesions relative to animals.Generation of diagnostic hypotheses and differential diagnoses made through the immediate visual recognition of clinical signs can be a fast and automatic process. The co-localization of significant brain activation for lesions and animals suggests that generating diagnostic hypotheses for lesions and naming animals are served by the same neuronal systems. Nevertheless, diagnosing lesions was cognitively more demanding and associated with more activation in higher order cortical areas. These results support the hypothesis that medical diagnoses based on prompt visual recognition of clinical signs and naming in everyday life are supported by similar

  9. Textile foreign body in a Green Iguana (Iguana iguana): Diagnostic imaging for localisation.

    Science.gov (United States)

    Lebens, M; Länger, B; Günther, P; Fehr, M; Mathes, K A

    2016-11-01

    This case report includes different diagnostic imaging methods for localization of textile foreign bodies in reptiles and shows the limitations and advantages of these methods. A six-year-old, male, green iguana was presented to our clinic after ingesting a sock 5 days earlier. Ultrasound, contrast x-ray, computed tomography and endoscopy were used to locate the foreign body before surgery. Attempts to remove the sock endoscopically failed. The sock was surgically removed via celiotomy and enterotomy.

  10. Laser-produced Au nanoparticles as X-ray contrast agents for diagnostic imaging

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Restuccia, N.; Cuzzocrea, S.; Paterniti, I.; Ielo, I.; Pergolizzi, S.; Cutroneo, Mariapompea; Kováčik, L.

    2017-01-01

    Roč. 50, č. 1 (2017), s. 51-60 ISSN 0017-1557 R&D Projects: GA MŠk LM2015056; GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : Au nanoparticles * Laser * X-ray diagnostic s * medical imaging * contrast medium Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.638, year: 2016

  11. Clinical diagnostic criteria of multiple sclerosis: the role of magnetic resonance imaging

    International Nuclear Information System (INIS)

    Belair, M.; Girard, M.

    2004-01-01

    The objective of this article is to summarize the diagnostic criteria recommended by the International Panel on the Diagnosis of Multiple Sclerosis in 2001. The recommendations of another working group, the Consortium of Multiple Sclerosis Centers Consensus Meeting, which met in Vancouver in 2001, concerning the diagnosis and follow-up of patients with multiple sclerosis are also presented in an effort to standardize the protocols for magnetic resonance imaging of these patients. (author)

  12. Imaging the Rural: Modernity and Agrarianism in Hiroshi Hamaya’s ‘Snow Land’ Photographs

    Directory of Open Access Journals (Sweden)

    Ross Tunney

    2015-06-01

    Full Text Available This article analyses the Snow Land photographic series by Japanese photographer Hiroshi Hamaya [1915–1999] in relation to issues of modernity, nostalgia and discourses of agrarianism in 1940s and 1950s Japan. Hamaya is one of Japan’s most celebrated and influential documentary photographers at both a national and international level. His Snow Land series presents an idyllic view of life in the small mountain villages of Japan’s Niigata Prefecture, emphasising a sense of community and spiritual meaning that Hamaya perceived to be lacking in modern society. In this sense, Snow Land constituted a critique of modernity. Through engagement with theorists such as Heidegger, Foucault and Barthes, as well as critical writings on agrarian ideology, this article investigates the underlying assumptions that govern Hamaya’s depiction of snow country, demonstrating that the series is shaped by a modern worldview and is tied to ideological discourses of agrarianism.

  13. Application of contemporary imaging methods in diagnostics of mild cognitive impairment

    International Nuclear Information System (INIS)

    Walecki, J.; Pawlowska-Detko, A.; Ignaciuk, K.; Gabryelewicz, T.; Barcikowska, M.

    2006-01-01

    Mild cognitive impairment (MCI) is defined as a heterogeneous clinical syndrome associated with high risk of the development of dementia, especially Alzheimer disease (AD). Owing to the recent advances in understanding of the molecular phenomena underlying AD there is a chance of introducing effective therapy for this disease in the near future. Therefore, improvement of early diagnostics methods and finding the markers of AD progression, especially in the high risk population of patients with MCI becomes a crucial issue. From the clinical point of view, great expectations are associated with neuroradiologic methods, which are hoped to make it possible to find the markers of conversion from MCI to dementia and the markers of dementia progression in subjects at risk of the development of AD. Growing interest in the problem of MCI diagnostics, reflected in numerous medical publications that have appeared during the recent few years, has prompted the authors to review and summarize the current knowledge concerning the application of modern neuroradiologic methods in the diagnostics of subjects with MCI. (author)

  14. Diagnostic value of radiological imaging pre- and post-drainage of pleural effusions.

    Science.gov (United States)

    Corcoran, John P; Acton, Louise; Ahmed, Asia; Hallifax, Robert J; Psallidas, Ioannis; Wrightson, John M; Rahman, Najib M; Gleeson, Fergus V

    2016-02-01

    Patients with an unexplained pleural effusion often require urgent investigation. Clinical practice varies due to uncertainty as to whether an effusion should be drained completely before diagnostic imaging. We performed a retrospective study of patients undergoing medical thoracoscopy for an unexplained effusion. In 110 patients with paired (pre- and post-drainage) chest X-rays and 32 patients with paired computed tomography scans, post-drainage imaging did not provide additional information that would have influenced the clinical decision-making process. © 2015 Asian Pacific Society of Respirology.

  15. Diagnostic imaging of the equine fetlock region using radiography and ultrasonography. Part 1: Soft tissues.

    Science.gov (United States)

    Vanderperren, Katrien; Saunders, Jimmy H

    2009-08-01

    The equine fetlock is the joint most commonly associated with lameness. Although the fetlock is regarded as a simple joint, diagnosis of a fetlock disorder can be a challenge and various imaging modalities are routinely used to arrive at an accurate diagnosis. This review describes the principal disorders affecting the soft tissues of the fetlock region and addresses some of the technical aspects involved in taking radiographic and ultrasonographic images of the different soft tissue lesions. A combination of radiography and ultrasonography is still the most commonly used diagnostic approach in clinical practice.

  16. From molecular imaging to systems diagnostics: Time for another paradigm shift?

    Energy Technology Data Exchange (ETDEWEB)

    Li, King C.P. [Department of Radiology, Methodist Hospital, Weill Cornell Medical College, 6565 Fannin Street, D280 Houston, TX 77030 (United States)], E-mail: kli@tmhs.org

    2009-05-15

    The term 'Molecular Imaging' has hit the consciousness of radiologists only in the past decade although many of the concepts that molecular imaging encompasses has been practiced in biomedical imaging, especially in nuclear medicine, for many decades. Many new imaging techniques have allowed us to interrogate biologic events at the cellular and molecular level in vivo in four dimensions but the challenge now is to translate these techniques into clinical practice in a way that will enable us to revolutionize healthcare delivery. The purpose of this article is to introduce the term 'Systems Diagnostics' and examine how radiologists can become translators of disparate sources of information into medical decisions and therapeutic actions.

  17. Vertical one-dimensional electron cyclotron emission imaging diagnostic for HT-7 tokamak

    International Nuclear Information System (INIS)

    Wang Jun; Xu Xiaoyuan; Wen Yizhi; Yu Changxuan; Wan Baonian; Luhmann, N.C.; Wang, Jian; Xia, Z.G.

    2005-01-01

    A vertical resolved 16-channel electron cyclotron emission imaging (ECEI) diagnostic has been developed and installed on the HT7 Tokamak for measuring plasma electron cyclotron emission with a temporal resolution of 0.5 us. The system is working on a fixed frequency 97.5 GHz in the first stage. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally via translation of one of the optical imaging elements. The detail of the system design and laboratory testing of the ECE Imaging optics are presented, together with HT7 plasma data. (author)

  18. Image processing and computer controls for video profile diagnostic system in the ground test accelerator (GTA)

    International Nuclear Information System (INIS)

    Wright, R.; Zander, M.; Brown, S.; Sandoval, D.; Gilpatrick, D.; Gibson, H.

    1992-01-01

    This paper describes the application of video image processing to beam profile measurements on the Ground Test Accelerator (GTA). A diagnostic was needed to measure beam profiles in the intermediate matching section (IMS) between the radio-frequency quadrupole (RFQ) and the drift tube linac (DTL). Beam profiles are measured by injecting puffs of gas into the beam. The light emitted from the beam-gas interaction is captured and processed by a video image processing system, generating the beam profile data. A general purpose, modular and flexible video image processing system, imagetool, was used for the GTA image profile measurement. The development of both software and hardware for imagetool and its integration with the GTA control system (GTACS) is discussed. The software includes specialized algorithms for analyzing data and calibrating the system. The underlying design philosophy of imagetool was tested by the experience of building and using the system, pointing the way for future improvements. (Author) (3 figs., 4 refs.)

  19. Image acquisition and analysis for beam diagnostics, applications of the Taiwan photon source

    International Nuclear Information System (INIS)

    Liao, C.Y.; Chen, J.; Cheng, Y.S.; Hsu, K.T.; Hu, K.H.; Kuo, C.H.; Wu, C.Y.

    2012-01-01

    Design and implementation of image acquisition and analysis is in proceeding for the Taiwan Photon Source (TPS) diagnostic applications. The optical system contains screen, lens, and lighting system. A CCD camera with Gigabit Ethernet interface (GigE Vision) will be a standard image acquisition device. Image acquisition will be done on EPICS IOC via PV channel and analysis the properties by using Matlab tool to evaluate the beam profile (sigma), beam size position and tilt angle et al. The EPICS IOC integrated with Matlab as a data processing system is not only could be used in image analysis but also in many types of equipment data processing applications. Progress of the project will be summarized in this report. (authors)

  20. Magnetic resonance imaging and spectroscopy- emerging trends in medical diagnostics and therapy

    International Nuclear Information System (INIS)

    Deshmukh, Sudha

    1997-01-01

    A dramatic acceleration in the application of magnetic resonance techniques in the field of medical sciences has been witnessed over the past decade. Magnetic Resonance Imaging (MRI) has been called the most significant development since the discovery of x-rays. As a method of visualizing cross-sectional anatomy, MRI is without peer. MRI images can now provide in-vivo anatomical details that were earlier available only with invasive procedures. Yet, despite its extraordinary potential, MRI has had limited success, if any, in tissue characterization using the three image parameters T 1 , T 2 and proton density ρ. MR spectroscopy has however bridged this gap to a large extent and opened up the possibility of studying in vivo chemistry. In the present article an attempt has been made to give a brief account of the application of magnetic resonance imaging and spectroscopy in medical diagnostics and therapy. The basic principles pertaining to MRI and MRS are also discussed in brief. (author)

  1. Development of local oscillator integrated antenna array for microwave imaging diagnostics

    International Nuclear Information System (INIS)

    Kuwahara, D.; Shinohara, S.; Ito, N.; Nagayama, Y.; Tsuchiya, H.; Yoshikawa, M.; Kohagura, J.; Yoshinaga, T.; Yamaguchi, S.; Kogi, Y.; Mase, A.

    2015-01-01

    Microwave imaging diagnostics are powerful tools that are used to obtain details of complex structures and behaviors of such systems as magnetically confined plasmas. For example, microwave imaging reflectometry and microwave imaging interferometers are suitable for observing phenomena that are involved with electron density fluctuations; moreover, electron cyclotron emission imaging diagnostics enable us to accomplish the significant task of observing MHD instabilities in large tokamaks. However, microwave imaging systems include difficulties in terms of multi-channelization and cost. Recently, we solved these problems by developing a Horn-antenna Mixer Array (HMA), a 50 - 110 GHz 1-D heterodyne- type antenna array, which can be easily stacked as a 2-D receiving array, because it uses an end-fire element. However, the HMA still evidenced problems owing to the requirement for local oscillation (LO) optics and an expensive high-power LO source. To solve this problem, we have developed an upgraded HMA, named the Local Integrated Antenna array (LIA), in which each channel has an internal LO supply using a frequency multiplier integrated circuit. Therefore, the proposed antenna array eliminates the need for both the LO optics and the high-power LO source. This paper describes the principle of the LIA, and provides details about an 8 channel prototype LIA

  2. Current status of diagnostic imaging in dental university hospitals in Japan

    International Nuclear Information System (INIS)

    Sasaki, Takehito; Fujita, Minoru; Katoh, Tsuguhisa; Kobayashi, Kaoru; Okano, Tomohiro; Sato, Kenji; Wada, Shinichi

    2004-01-01

    The diagnostic imaging examinations in all 29 dental university hospitals in Japan were analyzed during a 1-year period from April 1999 to March 2000. The total number of patients examined was 790859, which corresponded to 27271 patients per hospital on average, with a range from 7872 to 62904. Relative to the total number of patients, intraoral radiography was found to have been most frequently performed, 59% on average, with a range from 40% to 80%, depending on the hospital. Extraoral radiography, mostly panoramic radiography, was 36% on average with the range from 18% to 56%. A significant inverse correlation was observed between the percentages of intraoral and extraoral radiography, relative to the total number of all types of imaging examinations. Computed tomography (CT) examinations were performed with their own apparatuses in 27 hospitals with a frequency of 2.9% of patients in all imaging examinations on average and 9.1% at maximum. The scanning parameter of milliampere seconds (mAs) for individual types of routinely performed CT examinations varied widely, and thus the patient dose can be expected to be considerably reduced, without reducing the amount of diagnostic information to be obtained. Other imaging examinations performed were magnetic resonance imaging in 11 hospitals, X-ray fluoroscopy in 8 hospitals, ultrasonography in 20, nuclear medicine in 5, and bone densitometry in 1 hospital. (author)

  3. Diagnostic value of curved multiplanar reformatted images in multislice CT for the detection of resectable pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukushima, Hiromichi; Takada, Akira; Mori, Yoshimi; Suzuki, Kojiro; Sawaki, Akiko; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo; Itoh, Shigeki; Ikeda, Mitsuru

    2006-01-01

    The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12-40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone. (orig.)

  4. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  5. Beam diagnostics for traumatic brain injury

    Directory of Open Access Journals (Sweden)

    Nikol`skiy Yu.E.

    2012-06-01

    Full Text Available

    The paper presents aliterature review of domestic and foreign sources of modern methods of diagnostics imaging for traumatic brain injury. Information of the magnetic resonance imaging and computed tomography in the of this disease

  6. Quality control in diagnostic mammography: myths, realities and their importance in the final image quality

    International Nuclear Information System (INIS)

    Mora Rodriguez, Patricia

    2011-01-01

    Mammography is the most used tool for early detection of breast cancer and reduce mortality from this cause. Studies with ionizing radiation it is important that be justified and provide a quality image to make the diagnosis, to get more benefits and fewer risks. The problem is the difficult to obtain an image of the breast. Therefore, the commitment to quality mammography is to maximize the contrast, definition, resolution and reliability, thus minimizing noise and dose. A mammogram performed without quality don't detect early breast cancer and the study doesn't have sense. Quality mammography requires trained and experienced staff, modern equipment and in good conditions, correct positioning, right technical factors and appropriate viewing conditions. In addition, quality programs are required to reach to ensure quality, control in testing techniques and image quality. (author) [es

  7. 2D-3D image registration in diagnostic and interventional X-Ray imaging

    NARCIS (Netherlands)

    Bom, I.M.J. van der

    2010-01-01

    Clinical procedures that are conventionally guided by 2D x-ray imaging, may benefit from the additional spatial information provided by 3D image data. For instance, guidance of minimally invasive procedures with CT or MRI data provides 3D spatial information and visualization of structures that are

  8. Diagnostic accuracy of postmortem imaging vs autopsy-A systematic review.

    Science.gov (United States)

    Eriksson, Anders; Gustafsson, Torfinn; Höistad, Malin; Hultcrantz, Monica; Jacobson, Stella; Mejare, Ingegerd; Persson, Anders

    2017-04-01

    Background Postmortem imaging has been used for more than a century as a complement to medico-legal autopsies. The technique has also emerged as a possible alternative to compensate for the continuous decline in the number of clinical autopsies. To evaluate the diagnostic accuracy of postmortem imaging for various types of findings, we performed this systematic literature review. Data sources The literature search was performed in the databases PubMed, Embase and Cochrane Library through January 7, 2015. Relevant publications were assessed for risk of bias using the QUADAS tool and were classified as low, moderate or high risk of bias according to pre-defined criteria. Autopsy and/or histopathology were used as reference standard. Findings The search generated 2600 abstracts, of which 340 were assessed as possibly relevant and read in full-text. After further evaluation 71 studies were finally included, of which 49 were assessed as having high risk of bias and 22 as moderate risk of bias. Due to considerable heterogeneity - in populations, techniques, analyses and reporting - of included studies it was impossible to combine data to get a summary estimate of the diagnostic accuracy of the various findings. Individual studies indicate, however, that imaging techniques might be useful for determining organ weights, and that the techniques seem superior to autopsy for detecting gas Conclusions and Implications In general, based on the current scientific literature, it was not possible to determine the diagnostic accuracy of postmortem imaging and its usefulness in conjunction with, or as an alternative to autopsy. To correctly determine the usefulness of postmortem imaging, future studies need improved planning, improved methodological quality and larger materials, preferentially obtained from multi-center studies. Copyright © 2016. Published by Elsevier B.V.

  9. Diagnostic and Prognostic Significance of Methionine Uptake and Methionine Positron Emission Tomography Imaging in Gliomas

    Directory of Open Access Journals (Sweden)

    Kamalakannan Palanichamy

    2017-11-01

    Full Text Available The present most common image diagnostic tracer in clinical practice for glioma is 18F-fluorodeoxyglucose (FDG positron emission tomography (PET for brain tumors diagnosis and prognosis. PET is a promising molecular imaging technique, which provides real-time information on the metabolic behavior of the tracer. The diffusive nature of glioblastoma (GBM and heterogeneity often make the radiographic detection by FDG-PET inaccurate, and there is no gold standard. FDG-PET often leads to several controversies in making clinical decisions due to their uptake by normal surrounding tissues, and pose a challenge in delineating treatment-induced necrosis, edema, inflammation, and pseudoprogression. Thus, it is imperative to find new criteria independent of conventional morphological diagnosis to demarcate normal and tumor tissues. We have provided proof of concept studies for 11C methionine-PET (MET-PET imaging of gliomas, along with prognostic and diagnostic significance. MET-PET is not widely used in the United States, though clinical trials from Japan and Germany suggesting the diagnostic ability of MET-PET imaging are superior to FDG-PET imaging for brain tumors. A major impediment is the availability of the onsite cyclotron and isotopic carbon chemistry facilities. In this article, we have provided the scientific rationale and advantages of the use of MET-PET as GBM tracers. We extend our discussion on the expected pitfalls of using MET-PET and ways to overcome them by incorporating a translational component of profiling gene status in the methionine metabolic pathway. This translational correlative component to the MET-PET clinical trials can lead to a better understanding of the existing controversies and can enhance our knowledge for future randomization of GBM patients based on their tumor gene signatures to achieve better prognosis and treatment outcome.

  10. Diagnostic accuracy at several reduced radiation dose levels for CT imaging in the diagnosis of appendicitis

    Science.gov (United States)

    Zhang, Di; Khatonabadi, Maryam; Kim, Hyun; Jude, Matilda; Zaragoza, Edward; Lee, Margaret; Patel, Maitraya; Poon, Cheryce; Douek, Michael; Andrews-Tang, Denise; Doepke, Laura; McNitt-Gray, Shawn; Cagnon, Chris; DeMarco, John; McNitt-Gray, Michael

    2012-03-01

    Purpose: While several studies have investigated the tradeoffs between radiation dose and image quality (noise) in CT imaging, the purpose of this study was to take this analysis a step further by investigating the tradeoffs between patient radiation dose (including organ dose) and diagnostic accuracy in diagnosis of appendicitis using CT. Methods: This study was IRB approved and utilized data from 20 patients who underwent clinical CT exams for indications of appendicitis. Medical record review established true diagnosis of appendicitis, with 10 positives and 10 negatives. A validated software tool used raw projection data from each scan to create simulated images at lower dose levels (70%, 50%, 30%, 20% of original). An observer study was performed with 6 radiologists reviewing each case at each dose level in random order over several sessions. Readers assessed image quality and provided confidence in their diagnosis of appendicitis, each on a 5 point scale. Liver doses at each case and each dose level were estimated using Monte Carlo simulation based methods. Results: Overall diagnostic accuracy varies across dose levels: 92%, 93%, 91%, 90% and 90% across the 100%, 70%, 50%, 30% and 20% dose levels respectively. And it is 93%, 95%, 88%, 90% and 90% across the 13.5-22mGy, 9.6-13.5mGy, 6.4-9.6mGy, 4-6.4mGy, and 2-4mGy liver dose ranges respectively. Only 4 out of 600 observations were rated "unacceptable" for image quality. Conclusion: The results from this pilot study indicate that the diagnostic accuracy does not change dramatically even at significantly reduced radiation dose.

  11. Building the image of modern art : the rhetoric of two museums and the representation and canonization of modern art (1935-1975) : the Stedelijk Museum in Amsterdam and the Museum of Modern Art in New York

    NARCIS (Netherlands)

    Leigh, Nana

    2008-01-01

    The Rhetoric of Two Museums and the Representation and Canonization of Modern Art (1935-1975): The Stedelijk Museum in Amsterdam and the Museum of Modern Art in New York Museums of modern art have determined the course of modern art history. Their contributions to the representation and

  12. The inextricable axis of targeted diagnostic imaging and therapy: An immunological natural history approach

    International Nuclear Information System (INIS)

    Cope, Frederick O.; Abbruzzese, Bonnie; Sanders, James; Metz, Wendy; Sturms, Kristyn; Ralph, David; Blue, Michael; Zhang, Jane; Bracci, Paige; Bshara, Wiam; Behr, Spencer; Maurer, Toby; Williams, Kenneth; Walker, Joshua; Beverly, Allison; Blay, Brooke; Damughatla, Anirudh; Larsen, Mark; Mountain, Courtney; Neylon, Erin

    2016-01-01

    Summary: In considering the challenges of approaches to clinical imaging, we are faced with choices that sometimes are impacted by rather dogmatic notions about what is a better or worse technology to achieve the most useful diagnostic image for the patient. For example, is PET or SPECT most useful in imaging any particular disease dissemination? The dictatorial approach would be to choose PET, all other matters being equal. But is such a totalitarian attitude toward imaging selection still valid? In the face of new receptor targeted SPECT agents one must consider the remarkable specificity and sensitivity of these agents. 99m Tc-Tilmanocept is one of the newest of these agents, now approved for guiding sentinel node biopsy (SLNB) in several solid tumors. Tilmanocept has a K d of 3 × 10 −11 M, and it specificity for the CD206 receptor is unlike any other agent to date. This coupled with a number of facts, that specific disease-associated macrophages express this receptor (100 to 150 thousand receptors), that the receptor has multiple binding sites for tilmanocept (> 2 sites per receptor) and that these receptors are recycled every 15 min to bind more tilmanocept (acting as intracellular “drug compilers” of tilmanocept into non-degraded vesicles), gives serious pause as to how we select our approaches to diagnostic imaging. Clinically, the size of SLNs varies greatly, some, anatomically, below the machine resolution of SPECT. Yet, with tilmanocept targeting, the SLNs are highly visible with macrophages stably accruing adequate 99m Tc-tilmanocept counting statistics, as high target-to-background ratios can compensate for spatial resolution blurring. Importantly, it may be targeted imaging agents per se, again such as tilmanocept, which may significantly shrink any perceived chasm between the imaging technologies and anchor the diagnostic considerations in the targeting and specificity of the agent rather than any lingering dogma about the hardware as the basis

  13. Diagnostic Performance of Narrow Band Imaging for Laryngeal Cancer: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Sun, Changling; Han, Xue; Li, Xiaoying; Zhang, Yayun; Du, Xiaodong

    2017-04-01

    Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I 2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.

  14. Comparison of the diagnostic value of MR imaging and ophthalmoscopy for the staging of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Khurana, Aman; Wan, Wenshuai; Yeom, Kristen [Stanford University, Department of Radiology, Stanford, CA (United States); Eisenhut, Christina A. [Technical University of Munich, Department of Radiology, Munich (Germany); Ebrahimi, Katayoon B. [Johns Hopkins University, Department of Ocular Oncology, Baltimore, MD (United States); Patel, Chirag [University of California Davis, Department of Radiology, Davis, CA (United States); O' Brien, Joan M. [University of Pennsylvania, Department of Ophthalmology, Philadelphia, PA (United States); Daldrup-Link, Heike E. [Stanford University, Department of Radiology, Stanford, CA (United States); Stanford University, Department of Radiology, Pediatric Radiology Section, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2013-05-15

    To compare the diagnostic value of magnetic resonance (MR) imaging and ophthalmoscopy for staging of retinoblastoma. MR and ophthalmoscopic images of 36 patients who underwent enucleation were evaluated retrospectively following institutional review board approval. Histopathology being the standard of reference, the sensitivity and specificity of both diagnostic modalities were compared regarding growth pattern, iris neoangiogenesis, retinal detachment, vitreous seeds and optic nerve invasion. Data were analysed via McNemar's test. Both investigations showed no significant difference in accuracy for the detection of different tumour growth patterns (P = 0.80). Vitreous seeding detection was superior by ophthalmoscopy (P < 0.001). For prelaminar optic nerve invasion, MR imaging showed similar sensitivity as ophthalmoscopy but increased specificity of 40 % (CI 0.12-0.74) vs. 20 % (0.03-0.56). MR detected optic nerve involvement past the lamina cribrosa with a sensitivity of 80 % (0.28-0.99) and a specificity of 74 % (0.55-0.88). The absence of optic nerve enhancement excluded histopathological infiltration, but the presence of optic nerve enhancement included a high number of false positives (22-24 %). Ophthalmoscopy remains the method of choice for determining extent within the globe while MR imaging is useful for evaluating extraocular tumour extension. Thus, both have their own strengths and contribute uniquely to the staging of retinoblastoma. (orig.)

  15. Value of exercise thallium-201 imaging in patients with diagnostic and nondiagnostic exercise electrocardiograms

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Segal, B.L.

    1981-01-01

    The role of exercise imaging with thallium-201 in the evaluation of patients suspected of having coronary artery disease was studied in 194 patients undergoing diagnostic coronary arteriography. Ninety-eight patients had 70 percent or more narrowing of one or more coronary vessels and 96 patients had either no or insignificant coronary artery disease. One hundren twenty-three of the 194 patients had conclusive treadmill exercise electrocardiograms (either positive or negative), and 71 had inconclusive exercise electrocardiograms. The specificity of exercise imaging (97 percent) was higher than that of exercise electrocardiograms (86 percent, p less than 0.02). The specificity of both tests combined was not significantly different from that of exercise electrocardiograms alone. The sensitivity (79 percent) and specificity (95 percent) of exercise imaging were not significantly different in patients with inconclusive exercise electrocardiograms when compared with those in patients whose exercise electrocardiograms were conclusive. These data indicate that exercise imaging is sensitive and specific in diagnosing coronary artery disease in the presence of diagnostic as well as nondiagnostic exercise electrocardiograms and that propranolol therapy does not affect the results

  16. Use of hyperspectral imaging technology to develop a diagnostic support system for gastric cancer

    Science.gov (United States)

    Goto, Atsushi; Nishikawa, Jun; Kiyotoki, Shu; Nakamura, Munetaka; Nishimura, Junichi; Okamoto, Takeshi; Ogihara, Hiroyuki; Fujita, Yusuke; Hamamoto, Yoshihiko; Sakaida, Isao

    2015-01-01

    Hyperspectral imaging (HSI) is a new technology that obtains spectroscopic information and renders it in image form. This study examined the difference in the spectral reflectance (SR) of gastric tumors and normal mucosa recorded with a hyperspectral camera equipped with HSI technology and attempted to determine the specific wavelength that is useful for the diagnosis of gastric cancer. A total of 104 gastric tumors removed by endoscopic submucosal dissection from 96 patients at Yamaguchi University Hospital were recorded using a hyperspectral camera. We determined the optimal wavelength and the cut-off value for differentiating tumors from normal mucosa to establish a diagnostic algorithm. We also attempted to highlight tumors by image processing using the hyperspectral camera's analysis software. A wavelength of 770 nm and a cut-off value of 1/4 the corrected SR were selected as the respective optimal wavelength and cut-off values. The rates of sensitivity, specificity, and accuracy of the algorithm's diagnostic capability were 71%, 98%, and 85%, respectively. It was possible to enhance tumors by image processing at the 770-nm wavelength. HSI can be used to measure the SR in gastric tumors and to differentiate between tumorous and normal mucosa.

  17. Diagnostic imaging features of normal anal sacs in dogs and cats.

    Science.gov (United States)

    Jung, Yechan; Jeong, Eunseok; Park, Sangjun; Jeong, Jimo; Choi, Ul Soo; Kim, Min-Su; Kim, Namsoo; Lee, Kichang

    2016-09-30

    This study was conducted to provide normal reference features for canine and feline anal sacs using ultrasound, low-field magnetic resonance imaging (MRI) and radiograph contrast as diagnostic imaging tools. A total of ten clinically normal beagle dogs and eight clinically normally cats were included. General radiography with contrast, ultrasonography and low-field MRI scans were performed. The visualization of anal sacs, which are located at distinct sites in dogs and cats, is possible with a contrast study on radiography. Most surfaces of the anal sacs tissue, occasionally appearing as a hyperechoic thin line, were surrounded by the hypoechoic external sphincter muscle on ultrasonography. The normal anal sac contents of dogs and cats had variable echogenicity. Signals of anal sac contents on low-field MRI varied in cats and dogs, and contrast medium using T1-weighted images enhanced the anal sac walls more obviously than that on ultrasonography. In conclusion, this study provides the normal features of anal sacs from dogs and cats on diagnostic imaging. Further studies including anal sac evaluation are expected to investigate disease conditions.

  18. Diagnostic utility of intravenous contrast for MR imaging in pediatric appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, Gray R.; Renjen, Pooja; Kovanlikaya, Arzu [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Radiology, New York, NY (United States); Askin, Gulce; Giambrone, Ashley E. [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Biostatistics and Epidemiology, New York, NY (United States); Beneck, Debra [New York-Presbyterian Hospital/Weill Cornell Medicine, Department of Pathology, New York, NY (United States)

    2017-04-15

    Magnetic resonance imaging (MRI) is increasingly employed as a diagnostic modality for suspected appendicitis in children. However, there is uncertainty as to which MRI sequences are sufficient for safe, timely and accurate diagnosis. Several recent studies have described different MRI protocols, including exams both with and without the use of intravenous contrast. We hypothesized that intravenous contrast may be useful in some patients but could be safely omitted in others. All MRI examinations (n=112) performed at our institution for evaluating appendicitis in children were retrospectively reevaluated. Exams were reread by pediatric radiologists under three conditions: With postcontrast images, Without postcontrast images, and Without/With - selective use of postcontrast sequences only when needed for diagnostic certainty. Samples were scored as positive, negative or equivocal for appendicitis. Findings were compared to pathological or clinical follow-up in the medical record. Without the use of intravenous contrast yielded more equivocal results (12.4%) compared to With contrast (3.4%). By selectively using postcontrast sequences, the Without/With group yielded fewer equivocal results (1.1%) compared to Without while also reducing contrast use 79.8% compared to the With contrast group. No significant differences in conditional sensitivity or conditional specificity were detected among the three groups. MRI diagnosis of acute appendicitis can be performed without contrast for most patients; injection of contrast can be reserved for only those patients with equivocal non-contrast imaging. (orig.)

  19. From 'Image Gently' to image intelligently: a personalized perspective on diagnostic radiation risk

    Energy Technology Data Exchange (ETDEWEB)

    Guillerman, R.P. [Department of Pediatric Radiology, Texas Children' s Hospital, Baylor College of Medicine, Houston, TX (United States)

    2014-10-15

    The risk of ionizing radiation from diagnostic imaging has been a popular topic in the radiology literature and lay press. Communicating the magnitude of risk to patients and caregivers is problematic because of the uncertainty in estimates derived principally from epidemiological studies of large populations, and alternative approaches are needed to provide a scientific basis for personalized risk estimates. The underlying patient disease and life expectancy greatly influence risk projections. Research into the biological mechanisms of radiation-induced DNA damage and repair challenges the linear no-threshold dose-response assumption and reveals that individuals vary in sensitivity to radiation. Studies of decision-making psychology show that individuals are highly susceptible to irrational biases when judging risks. Truly informed medical decision-making that respects patient autonomy requires appropriate framing of radiation risks in perspective with other risks and with the benefits of imaging. To follow the principles of p