WorldWideScience

Sample records for model proposed radiographic

  1. a Proposed Benchmark Problem for Scatter Calculations in Radiographic Modelling

    Science.gov (United States)

    Jaenisch, G.-R.; Bellon, C.; Schumm, A.; Tabary, J.; Duvauchelle, Ph.

    2009-03-01

    Code Validation is a permanent concern in computer modelling, and has been addressed repeatedly in eddy current and ultrasonic modeling. A good benchmark problem is sufficiently simple to be taken into account by various codes without strong requirements on geometry representation capabilities, focuses on few or even a single aspect of the problem at hand to facilitate interpretation and to avoid that compound errors compensate themselves, yields a quantitative result and is experimentally accessible. In this paper we attempt to address code validation for one aspect of radiographic modeling, the scattered radiation prediction. Many NDT applications can not neglect scattered radiation, and the scatter calculation thus is important to faithfully simulate the inspection situation. Our benchmark problem covers the wall thickness range of 10 to 50 mm for single wall inspections, with energies ranging from 100 to 500 keV in the first stage, and up to 1 MeV with wall thicknesses up to 70 mm in the extended stage. A simple plate geometry is sufficient for this purpose, and the scatter data is compared on a photon level, without a film model, which allows for comparisons with reference codes like MCNP. We compare results of three Monte Carlo codes (McRay, Sindbad and Moderato) as well as an analytical first order scattering code (VXI), and confront them to results obtained with MCNP. The comparison with an analytical scatter model provides insights into the application domain where this kind of approach can successfully replace Monte-Carlo calculations.

  2. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  3. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nordeck, Shaun M. [University of Texas Southwestern Medical College, Dallas, TX (United States); University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Koerper, Conrad E.; Adler, Aaron [University of Texas Southwestern Medical College, Dallas, TX (United States); Malhotra, Vidur; Xi, Yin [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Liu, George T. [University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States); Chhabra, Avneesh [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States)

    2017-05-15

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR. (orig.)

  4. Personalized models of bones based on radiographic photogrammetry.

    Science.gov (United States)

    Berthonnaud, E; Hilmi, R; Dimnet, J

    2009-07-01

    The radiographic photogrammetry is applied, for locating anatomical landmarks in space, from their two projected images. The goal of this paper is to define a personalized geometric model of bones, based uniquely on photogrammetric reconstructions. The personalized models of bones are obtained from two successive steps: their functional frameworks are first determined experimentally, then, the 3D bone representation results from modeling techniques. Each bone functional framework is issued from direct measurements upon two radiographic images. These images may be obtained using either perpendicular (spine and sacrum) or oblique incidences (pelvis and lower limb). Frameworks link together their functional axes and punctual landmarks. Each global bone volume is decomposed in several elementary components. Each volumic component is represented by simple geometric shapes. Volumic shapes are articulated to the patient's bone structure. The volumic personalization is obtained by best fitting the geometric model projections to their real images, using adjustable articulations. Examples are presented to illustrating the technique of personalization of bone volumes, directly issued from the treatment of only two radiographic images. The chosen techniques for treating data are then discussed. The 3D representation of bones completes, for clinical users, the information brought by radiographic images.

  5. Segmentation of lung fields using Chan-Vese active contour model in chest radiographs

    Science.gov (United States)

    Sohn, Kiwon

    2011-03-01

    A CAD tool for chest radiographs consists of several procedures and the very first step is segmentation of lung fields. We develop a novel methodology for segmentation of lung fields in chest radiographs that can satisfy the following two requirements. First, we aim to develop a segmentation method that does not need a training stage with manual estimation of anatomical features in a large training dataset of images. Secondly, for the ease of implementation, it is desirable to apply a well established model that is widely used for various image-partitioning practices. The Chan-Vese active contour model, which is based on Mumford-Shah functional in the level set framework, is applied for segmentation of lung fields. With the use of this model, segmentation of lung fields can be carried out without detailed prior knowledge on the radiographic anatomy of the chest, yet in some chest radiographs, the trachea regions are unfavorably segmented out in addition to the lung field contours. To eliminate artifacts from the trachea, we locate the upper end of the trachea, find a vertical center line of the trachea and delineate it, and then brighten the trachea region to make it less distinctive. The segmentation process is finalized by subsequent morphological operations. We randomly select 30 images from the Japanese Society of Radiological Technology image database to test the proposed methodology and the results are shown. We hope our segmentation technique can help to promote of CAD tools, especially for emerging chest radiographic imaging techniques such as dual energy radiography and chest tomosynthesis.

  6. Proposed reliability cost model

    Science.gov (United States)

    Delionback, L. M.

    1973-01-01

    The research investigations which were involved in the study include: cost analysis/allocation, reliability and product assurance, forecasting methodology, systems analysis, and model-building. This is a classic example of an interdisciplinary problem, since the model-building requirements include the need for understanding and communication between technical disciplines on one hand, and the financial/accounting skill categories on the other. The systems approach is utilized within this context to establish a clearer and more objective relationship between reliability assurance and the subcategories (or subelements) that provide, or reenforce, the reliability assurance for a system. Subcategories are further subdivided as illustrated by a tree diagram. The reliability assurance elements can be seen to be potential alternative strategies, or approaches, depending on the specific goals/objectives of the trade studies. The scope was limited to the establishment of a proposed reliability cost-model format. The model format/approach is dependent upon the use of a series of subsystem-oriented CER's and sometimes possible CTR's, in devising a suitable cost-effective policy.

  7. Kinetic models for the development of density in photographic and radiographic film

    International Nuclear Information System (INIS)

    Darvell, B.W.; Prince Philip Dental Hospital, Hong Kong)

    1985-01-01

    The behaviour of radiographic and photographic films is usually described in terms of a plot of optical density against log (exposure). This form, based on a desired 'ideal' rather than any theory of the actual process, leads to difficulties of interpretation and arbitrary 'speed' determinations. Data collected have been shown to fit chemical kinetic models of differing order, depending on film and radiation type, with the rate constant providing a rational speed parameter. The order of the model seems to be associated with the number of quantum hits required for grain developability. A rational contrast index is proposed. (author)

  8. Analysis of fuel-bundle radiographs using modeling

    International Nuclear Information System (INIS)

    Demuth, H.B.

    1975-07-01

    It was desired to estimate the thickness of gaps imaged on highly degraded radiographs. A powerful mathematical method for estimating gap widths was developed and applied. The problem, the techniques used to solve the problem, and results, conclusions, and suggestions for future work are presented. (U.S.)

  9. A radiographic study on the prevalence of knife-edge residual alveolar ridge at proposed dental implant sites

    International Nuclear Information System (INIS)

    AlFaleh, Wafaa

    2009-01-01

    Dental implants are widely used in restoration of completely or partially edentulous dental arches. Before placement of endosseous implants in the jaws, both the quantity and quality of the residual ridge must be assessed radiographically. Remodeling activity after tooth extraction is localized primarily at the crestal area of the residual ridges, resulting in reduction of the height of bone and creation of various three-dimensional shapes of the residual ridges. When bone resorption at the lingual and buccal aspects is greater than that at the crestal area, a knife-edge type of residual ridge develops. The aim of this study was to evaluate the prevalence of the knife-edge morphology of the residual alveolar bone at proposed implant sites in partially or completely edentulous patients. Computed tomography (CT) cross-sectional images of the upper and lower jaws were assessed at the proposed sites before implant placement. Images of 258 proposed implant sites belonging to 30 patients were assessed radiographically. In 120 proposed implant sites out of 258 (46.5%), the residual alveolar ridge had a knife-edge configuration, the majority belonging to completely edentulous patients who lost their teeth more than ten years previously. High prevalence of knife-edge ridge was found, therefore, replacement of missing teeth by immediate implant is recommended to prevent atrophy or knife-edge morphology of the residual ridge. (author)

  10. Radiographic Detectability of Retained Neuropatties in a Cadaver Model.

    Science.gov (United States)

    Luo, Wangjian Thomas; Almack, Robert; Mawson, John B; Cochrane, David Douglas

    2015-08-01

    Counts are the commonest method used to ensure that all sponges and neuropatties are removed from a surgical site before closure. When the count is not reconciled, plain radiographs of the operative site are taken to determine whether the missing patty has been left in the wound. The purpose of this study was to describe the detectability of commonly used neuropatties in the clinical setting using digital technologies. Neuropatties were implanted into the anterior and posterior cranial fossae and the thoracolumbar extradural space of a mature male cadaver. Four neuropatty sizes were used: 3 × 1 in, 2 × ½ in, ½ × ½ in, and ¼ × ¼ in. Neuropatties, with size and location chosen at random, were placed in the surgical sites and anteroposterior/posterior-anterior and lateral radiographs were taken using standard portable digital radiographic equipment. Six clinicians reviewed the digital images for the presence or absence of neuropatties. The readers were not aware of the number and size of the patties that were included in each image. The detectability of neuropatties is dependent on the size of the neuropatty's radiopaque marker and the operative site. Neuropatties measuring 2 × ½ in and 3 × 1 in were detected reliably regardless of the operative site. ¼ × ¼ in neuropatties were poorly detected by neurosurgeons and radiologists in all three operative sites. Readers of various experience and background were similar in their ability to detect neuropatties under these conditions. Under simulated operating room conditions and using currently available neuropatties and plain radiograph imaging technology, small ¼-in and ½-in neuropatties are poorly visible/detectable on digital images. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Unsupervised segmentation of lung fields in chest radiographs using multiresolution fractal feature vector and deformable models.

    Science.gov (United States)

    Lee, Wen-Li; Chang, Koyin; Hsieh, Kai-Sheng

    2016-09-01

    Segmenting lung fields in a chest radiograph is essential for automatically analyzing an image. We present an unsupervised method based on multiresolution fractal feature vector. The feature vector characterizes the lung field region effectively. A fuzzy c-means clustering algorithm is then applied to obtain a satisfactory initial contour. The final contour is obtained by deformable models. The results show the feasibility and high performance of the proposed method. Furthermore, based on the segmentation of lung fields, the cardiothoracic ratio (CTR) can be measured. The CTR is a simple index for evaluating cardiac hypertrophy. After identifying a suspicious symptom based on the estimated CTR, a physician can suggest that the patient undergoes additional extensive tests before a treatment plan is finalized.

  12. Customization of a generic 3D model of the distal femur using diagnostic radiographs.

    Science.gov (United States)

    Schmutz, B; Reynolds, K J; Slavotinek, J P

    2008-01-01

    A method for the customization of a generic 3D model of the distal femur is presented. The customization method involves two steps: acquisition of calibrated orthogonal planar radiographs; and linear scaling of the generic model based on the width of a subject's femoral condyles as measured on the planar radiographs. Planar radiographs of seven intact lower cadaver limbs were obtained. The customized generic models were validated by comparing their surface geometry with that of CT-reconstructed reference models. The overall mean error was 1.2 mm. The results demonstrate that uniform scaling as a first step in the customization process produced a base model of accuracy comparable to other models reported in the literature.

  13. Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

    Science.gov (United States)

    Jeyapalina, Sujee; Beck, James Peter; Bachus, Kent N; Chalayon, Ornusa; Bloebaum, Roy D

    2014-10-01

    Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.

  14. Proposed Reliability/Cost Model

    Science.gov (United States)

    Delionback, L. M.

    1982-01-01

    New technique estimates cost of improvement in reliability for complex system. Model format/approach is dependent upon use of subsystem cost-estimating relationships (CER's) in devising cost-effective policy. Proposed methodology should have application in broad range of engineering management decisions.

  15. Model-based vision system for automatic recognition of structures in dental radiographs

    Science.gov (United States)

    Acharya, Raj S.; Samarabandu, Jagath K.; Hausmann, E.; Allen, K. A.

    1991-07-01

    X-ray diagnosis of destructive periodontal disease requires assessing serial radiographs by an expert to determine the change in the distance between cemento-enamel junction (CEJ) and the bone crest. To achieve this without the subjectivity of a human expert, a knowledge based system is proposed to automatically locate the two landmarks which are the CEJ and the level of alveolar crest at its junction with the periodontal ligament space. This work is a part of an ongoing project to automatically measure the distance between CEJ and the bone crest along a line parallel to the axis of the tooth. The approach presented in this paper is based on identifying a prominent feature such as the tooth boundary using local edge detection and edge thresholding to establish a reference and then using model knowledge to process sub-regions in locating the landmarks. Segmentation techniques invoked around these regions consists of a neural-network like hierarchical refinement scheme together with local gradient extraction, multilevel thresholding and ridge tracking. Recognition accuracy is further improved by first locating the easily identifiable parts of the bone surface and the interface between the enamel and the dentine and then extending these boundaries towards the periodontal ligament space and the tooth boundary respectively. The system is realized as a collection of tools (or knowledge sources) for pre-processing, segmentation, primary and secondary feature detection and a control structure based on the blackboard model to coordinate the activities of these tools.

  16. A scientific model to determine the optimal radiographer staffing component in a nuclear medicine department

    International Nuclear Information System (INIS)

    Shipanga, A.N.; Ellmann, A.

    2004-01-01

    Full text: Introduction: Nuclear medicine in South Africa is developing fast. Much has changed since the constitution of a scientific model for determining an optimum number of radiographer posts in a Nuclear Medicine department in the late 1980's. Aim: The aim of this study was to ascertain whether the number of radiographers required by a Nuclear Medicine department can still be determined according to the norms established in 1988. Methods: A quantitative study using non-experimental evaluation design was conducted to determine the ratios between current radiographer workload and staffing norms. The workload ratios were analysed using the procedures statistics of the Nuclear Medicine department at Tygerberg Hospital. Radiographers provided data about their activities related to patient procedures, including information about the condition of the patients, activities in the radiopharmaceutical laboratory, and patient related administrative tasks. These were factored into an equation relating this data to working hours, including vacation and sick leave. The calculation of Activity Standards and an annual Standard Workload was used to finally calculate the staffing requirements for a Nuclear Medicine department. Results: Preliminary data confirmed that old staffing norms cannot be used in a modern Nuclear Medicine department. Protocols for several types of study have changed, including the additional acquisition of tomographic studies. Interest in the use of time-consuming non-imaging studies has been revived and should be factored Into the equation. Conclusions: All Nuclear Medicine departments In South Africa, where the types of studies performed have changed over the past years, should look carefully at their radiographer staffing ratio to ascertain whether the number of radiographers needed is adequate for the current workload. (author)

  17. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model.

    Science.gov (United States)

    Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho

    2015-01-01

    Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.

  18. Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

    Science.gov (United States)

    Hsu, Shu-Hui; Kulasekere, Ravi; Roberson, Peter L

    2010-08-05

    Film calibration is time-consuming work when dose accuracy is essential while working in a range of photon scatter environments. This study uses the single-target single-hit model of film response to fit the calibration curves as a function of calibration method, processor condition, field size and depth. Kodak XV film was irradiated perpendicular to the beam axis in a solid water phantom. Standard calibration films (one dose point per film) were irradiated at 90 cm source-to-surface distance (SSD) for various doses (16-128 cGy), depths (0.2, 0.5, 1.5, 5, 10 cm) and field sizes (5 × 5, 10 × 10 and 20 × 20 cm²). The 8-field calibration method (eight dose points per film) was used as a reference for each experiment, taken at 95 cm SSD and 5 cm depth. The delivered doses were measured using an Attix parallel plate chamber for improved accuracy of dose estimation in the buildup region. Three fitting methods with one to three dose points per calibration curve were investigated for the field sizes of 5 × 5, 10 × 10 and 20 × 20 cm². The inter-day variation of model parameters (background, saturation and slope) were 1.8%, 5.7%, and 7.7% (1 σ) using the 8-field method. The saturation parameter ratio of standard to 8-field curves was 1.083 ± 0.005. The slope parameter ratio of standard to 8-field curves ranged from 0.99 to 1.05, depending on field size and depth. The slope parameter ratio decreases with increasing depth below 0.5 cm for the three field sizes. It increases with increasing depths above 0.5 cm. A calibration curve with one to three dose points fitted with the model is possible with 2% accuracy in film dosimetry for various irradiation conditions. The proposed fitting methods may reduce workload while providing energy dependence correction in radiographic film dosimetry. This study is limited to radiographic XV film with a Lumisys scanner.

  19. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    Energy Technology Data Exchange (ETDEWEB)

    Pegg, E.C., E-mail: elise.pegg@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Mellon, S.J., E-mail: stephen.mellon@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Salmon, G. [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Alvand, A., E-mail: abtin.alvand@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Pandit, H., E-mail: hemant.pandit@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Murray, D.W., E-mail: david.murray@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom); Gill, H.S., E-mail: richie.gill@ndorms.ox.ac.uk [University of Oxford, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD (United Kingdom)

    2012-10-15

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.

  20. Improved radiograph measurement inter-observer reliability by use of statistical shape models

    International Nuclear Information System (INIS)

    Pegg, E.C.; Mellon, S.J.; Salmon, G.; Alvand, A.; Pandit, H.; Murray, D.W.; Gill, H.S.

    2012-01-01

    Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p > 0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p = 0.0001). Less time (15 s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements

  1. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. A proposed radiographic classification scheme for congenital thoracic vertebral malformations in brachycephalic "screw-tailed" dog breeds.

    Science.gov (United States)

    Gutierrez-Quintana, Rodrigo; Guevar, Julien; Stalin, Catherine; Faller, Kiterie; Yeamans, Carmen; Penderis, Jacques

    2014-01-01

    Congenital vertebral malformations are common in brachycephalic "screw-tailed" dog breeds such as French bulldogs, English bulldogs, Boston terriers, and pugs. The aim of this retrospective study was to determine whether a radiographic classification scheme developed for use in humans would be feasible for use in these dog breeds. Inclusion criteria were hospital admission between September 2009 and April 2013, neurologic examination findings available, diagnostic quality lateral and ventro-dorsal digital radiographs of the thoracic vertebral column, and at least one congenital vertebral malformation. Radiographs were retrieved and interpreted by two observers who were unaware of neurologic status. Vertebral malformations were classified based on a classification scheme modified from a previous human study and a consensus of both observers. Twenty-eight dogs met inclusion criteria (12 with neurologic deficits, 16 with no neurologic deficits). Congenital vertebral malformations affected 85/362 (23.5%) of thoracic vertebrae. Vertebral body formation defects were the most common (butterfly vertebrae 6.6%, ventral wedge-shaped vertebrae 5.5%, dorsal hemivertebrae 0.8%, and dorso-lateral hemivertebrae 0.5%). No lateral hemivertebrae or lateral wedge-shaped vertebrae were identified. The T7 vertebra was the most commonly affected (11/28 dogs), followed by T8 (8/28 dogs) and T12 (8/28 dogs). The number and type of vertebral malformations differed between groups (P = 0.01). Based on MRI, dorsal, and dorso-lateral hemivertebrae were the cause of spinal cord compression in 5/12 (41.6%) of dogs with neurologic deficits. Findings indicated that a modified human radiographic classification system of vertebral malformations is feasible for use in future studies of brachycephalic "screw-tailed" dogs. © 2014 American College of Veterinary Radiology.

  3. The 'model omnitron' proposed experiment

    International Nuclear Information System (INIS)

    Sestero, A.

    1997-05-01

    The Model Omitron is a compact tokamak experiment which is designed by the Fusion Engineering Unit of ENEA and CITIF CONSORTIUM. The building of Model Omitron would allow for full testing of Omitron engineering, and partial testing of Omitron physics -at about 1/20 of the cost that has been estimated for the larger parent machine. In particular, due to the unusually large ohmic power densities (up to 100 times the nominal value in the Frascati FTU experiment), in Model Omitron the radial energy flux is reaching values comparable or higher than envisaged of the larger ignition experiments Omitron, Ignitor and Iter. Consequently, conditions are expected to occur at the plasma border in the scrape-off layer of Model Omitron, which are representative of the quoted larger experiments. Moreover, since all this will occur under ohmic heating alone, one will hopefully be able to derive an energy transport model fo the ohmic heating regime that is valid over a range of plasma parameters (in particular, of the temperature parameter) wider than it was possible before. In the Model Omitron experiment, finally - by reducing the plasma current and/or the toroidal field down to, say, 1/3 or 1/4 of the nominal values -additional topics can be tackled, such as: large safety-factor configurations (of interest for improving confinement), large aspect-ratio configurations (of interest for the investigation of advanced concepts in tokamaks), high beta (with RF heating -also of interest for the investigation of advanced concepts in tokamaks), long pulse discharges (of interest for demonstrating stationary conditions in the current profile)

  4. Women's Language Model: A Proposal.

    Science.gov (United States)

    Dumas, Bethany K.

    It is possible to think of women's language in terms of the model implied by the following statement. Insofar as native speakers of English are concerned, the language of women in America has four sets of components: those shared with the language of men in America; those shared, in varying proportions, with other women living in patriarchies;…

  5. A process model in continuing professional development: Exploring diagnostic radiographers' views

    Energy Technology Data Exchange (ETDEWEB)

    Henwood, Suzanne M. [Henwood Associates (South East) Ltd, Coaching and Training, 38 Tudor Crescent, Otford, TN14 5QT, Sevenoaks, Kent (United Kingdom)], E-mail: henwoodassociates@btinternet.com; Taket, Ann [Centre for Health through Action on Social Exclusion (CHASE), School of Health and Social Development, Faculty of Health and Behavioural Sciences, Deakin University, 221 Burwood Highway, Burwood, Vic 3125 (Australia)], E-mail: ann.taket@deakin.edu.au

    2008-08-15

    This article is based on an exploratory, interpretative grounded theory study that looked at practitioners' perceptions of continuing professional development (CPD) in diagnostic radiography in the UK. Using a combination of in-depth interviews and secondary analysis of published material, a dynamic CPD process model was generated. The study aimed to explore what radiographers understood by the term CPD and whether it was perceived to have any impact on clinical practice. The study aimed to identify and investigate the components of CPD and how they interact with one another, to help to explain what is happening within CPD and what contributes to its effectiveness. The CPD process was shown to be complex, dynamic and centred on the Individual. Supporting components of Facilitation and External Influences were identified as important in maximising the potential impact of CPD. The three main categories were shown to interact dynamically and prior to Participation were shown to have a 'superadditive' effect, where the total effect was greater than the sum of the three individual parts. This study showed that radiographers are generally unaware of the holistic concept of CPD, using instead narrow definitions of CPD with little or no expectation of any impact on practice, focusing predominantly on personal gain. The model produced in the study provided a tool that practitioners reported was helpful in reflecting on their own involvment in CPD.

  6. Synthetic digital radiographs using exposure computer models of Voxels / EGS4 Phantoms

    International Nuclear Information System (INIS)

    Kenned, Roberto; Vieira, Jose W.; Lima, Fernando R.A.; Loureiro, Eduardo

    2008-01-01

    The objective of this work is to produce synthetic digital radiographs from synthetic phantoms with the use of a Computational Model of Exposition (MCE). The literature explains a model consisted on a phantom, a Monte Carlo code and an algorithm of a radioactive source. In this work it was used the FAX phantom (Female Adult voXel), besides the EGS4 system code Eletron Shower-range version 4) and an external source, similar to that used in diagnostic radiology. The implementation of MCE creates files with information on external energy deposited in the voxels of fantoma used, here called EnergiaPorVoxel.dat. These files along with the targeted phantom (fax.sgi) worked as data entry for the DIP software (Digital Imaging Processing) to build the synthetic phantoms based on energy and the effective dose. This way you can save each slice that is the stack of pictures of these phantoms synthetics, which have been called synthetic digital radiography. Using this, it is possible to use techniques of emphasis in space to increase the contrast or elineate contours between organs and tissues. The practical use of these images is not only to allow a planning of examinations performed in clinics and hospitals and reducing unnecessary exposure to patients by error of radiographic techniques. (author)

  7. A process model in continuing professional development: Exploring diagnostic radiographers' views

    International Nuclear Information System (INIS)

    Henwood, Suzanne M.; Taket, Ann

    2008-01-01

    This article is based on an exploratory, interpretative grounded theory study that looked at practitioners' perceptions of continuing professional development (CPD) in diagnostic radiography in the UK. Using a combination of in-depth interviews and secondary analysis of published material, a dynamic CPD process model was generated. The study aimed to explore what radiographers understood by the term CPD and whether it was perceived to have any impact on clinical practice. The study aimed to identify and investigate the components of CPD and how they interact with one another, to help to explain what is happening within CPD and what contributes to its effectiveness. The CPD process was shown to be complex, dynamic and centred on the Individual. Supporting components of Facilitation and External Influences were identified as important in maximising the potential impact of CPD. The three main categories were shown to interact dynamically and prior to Participation were shown to have a 'superadditive' effect, where the total effect was greater than the sum of the three individual parts. This study showed that radiographers are generally unaware of the holistic concept of CPD, using instead narrow definitions of CPD with little or no expectation of any impact on practice, focusing predominantly on personal gain. The model produced in the study provided a tool that practitioners reported was helpful in reflecting on their own involvment in CPD

  8. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  9. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  10. Coralline hydroxyapatite bone graft substitutes in a canine metaphyseal defect model: Radiographic-biomechanical correlation

    International Nuclear Information System (INIS)

    Sartoris, D.J.; Resnick, D.; Holmes, R.E.; Tencer, A.F.; Texas Univ., Dallas; Mooney, V.

    1986-01-01

    Radiographic and biomechanical assessment of a new type of bone graft substitute derived from reef-building sea coral was performed in a canine metaphyseal defect model. Blocks of this material and autogenous iliac crest graft were implanted, respectively, into the right and left proximal tibial metaphyses of eight dogs. Qualitative and quantitative radiographic evaluation was performed in the immediate postoperative period and at 6 months after surgery. Biomechanical testing was carried out on all grafts following harvest at 6 months, as well as on nonimplanted coralline hydroxyapatite and autogenous iliac cancellous bone. In contrast to autografts, incorporation of coralline implants was characterized by predictable osseous growth and apposition with preservation of intrinsic architecture. Greater percent increase in radiography density, higher ultimate compressive strength, and lower stiffness with incorporation were documented advantages of coralline hydroxyapatite over autogenous graft. Densitometric measurements correlated moderately with strength for both types of graft material (r=0.65). These promising results have important implications to the clinical application of coralline hydroxyapatite bone graft substitutes as an alternative to autogenous grafting. (orig.)

  11. Methodological model of chronic stress associated with ligature-induced periodontitis in rats: a radiographic study

    Directory of Open Access Journals (Sweden)

    Alex Semenoff Segundo

    2010-12-01

    Full Text Available This study evaluated the time efficiency of stress associated with ligature-induced periodontitis in rats. Sixty adult Wistar rats, housed in temperature-controlled rooms and receiving water and food ad libitum, were randomly separated into stress (n = 30 or control groups (n = 30. All animals were anesthetized, and nylon ligatures were placed at the gingival margin level of the maxillary right second molars. After the induction of periodontitis, rats in the stress group were subjected to physical restraint for 12 hours daily. The animals were euthanized after 7, 15 and 30 days by anesthetic overdose (10 animals per group per period. The right hemimaxillae were stored in formalin solution for 48 hours. Parallel radiographic images of the hemimaxillae were taken and processed following standard procedures. Radiographic examination was performed by a blinded and previously calibrated investigator. Bone height level was measured, and data were submitted to analysis of variance and post hoc Bonferroni tests (p 0.05. Restraint stress modulates the short-term progression of periodontal disease in rats. Therefore, the 12-hour daily physical restraint stress model in rats applied for up to 15 days is suitable for the investigation of the combined effect of ligation and restraint stress on periodontal degradation.

  12. Perona Malik anisotropic diffusion model using Peaceman Rachford scheme on digital radiographic image

    International Nuclear Information System (INIS)

    Halim, Suhaila Abd; Razak, Rohayu Abd; Ibrahim, Arsmah; Manurung, Yupiter HP

    2014-01-01

    In image processing, it is important to remove noise without affecting the image structure as well as preserving all the edges. Perona Malik Anisotropic Diffusion (PMAD) is a PDE-based model which is suitable for image denoising and edge detection problems. In this paper, the Peaceman Rachford scheme is applied on PMAD to remove unwanted noise as the scheme is efficient and unconditionally stable. The capability of the scheme to remove noise is evaluated on several digital radiography weld defect images computed using MATLAB R2009a. Experimental results obtained show that the Peaceman Rachford scheme improves the image quality substantially well based on the Peak Signal to Noise Ratio (PSNR). The Peaceman Rachford scheme used in solving the PMAD model successfully removes unwanted noise in digital radiographic image

  13. Perona Malik anisotropic diffusion model using Peaceman Rachford scheme on digital radiographic image

    Energy Technology Data Exchange (ETDEWEB)

    Halim, Suhaila Abd; Razak, Rohayu Abd; Ibrahim, Arsmah [Center of Mathematics Studies, Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, 40450 Shah Alam. Selangor DE (Malaysia); Manurung, Yupiter HP [Advanced Manufacturing Technology Excellence Center (AMTEx), Faculty of Mechanical Engineering, Universiti Teknologi MARA, 40450 Shah Alam. Selangor DE (Malaysia)

    2014-06-19

    In image processing, it is important to remove noise without affecting the image structure as well as preserving all the edges. Perona Malik Anisotropic Diffusion (PMAD) is a PDE-based model which is suitable for image denoising and edge detection problems. In this paper, the Peaceman Rachford scheme is applied on PMAD to remove unwanted noise as the scheme is efficient and unconditionally stable. The capability of the scheme to remove noise is evaluated on several digital radiography weld defect images computed using MATLAB R2009a. Experimental results obtained show that the Peaceman Rachford scheme improves the image quality substantially well based on the Peak Signal to Noise Ratio (PSNR). The Peaceman Rachford scheme used in solving the PMAD model successfully removes unwanted noise in digital radiographic image.

  14. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  15. Radiographic, densitometric, and biomechanical effects of recombinant canine somatotropin in an unstable ostectomy gap model of bone healing in dogs

    International Nuclear Information System (INIS)

    Millis, D.L.; Wilkens, B.E.; Daniel, G.B.; Hubner, K.; Mathews, A.; Buonomo, F.C.; Patell, K.R.; Weigel, J.P.

    1998-01-01

    Objective: To determine the effect of recombinant canine somatotropin (STH) on radiographic, densitometric, and biomechanical aspects of bone healing using an unstable ostectomy gap model. Study Design: After an ostectomy of the midshaft radius, bone healing was evaluated over an 8-week period in control dogs (n = 4) and dogs receiving recombinant canine STH (n = 4). Animals Or Sample Population: Eight sexually intact female Beagle dogs, 4 to 5 years old. Methods: Bone healing was evaluated by qualitative and quantitative evaluation of serial radiographs every 2 weeks. Terminal dual-energy x-ray absorptiometry and three-point bending biomechanical testing were also performed. Results: Dogs receiving STH had more advanced radiographic healing of ostectomy sites. Bone area, bone mineral content, and bone density were two to five times greater at the ostectomy sites of treated dogs. Ultimate load at failure and stiffness were three and five times greater in dogs receiving STH. Conclusions: Using the ostectomy gap model, recombinant canine STH enhanced the radiographic, densitometric, and biomechanical aspects of bone healing in dogs. Clinical Relevance: Dogs at risk for delayed healing of fractures may benefit from treatment with recombinant canine STH

  16. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  17. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  18. Proposal for an ecoradiological centre model

    International Nuclear Information System (INIS)

    Perovic, S.M.; Zunic, Z.; Demajo, M.; Konjevic, N.

    1998-01-01

    The problem of establishing an optimal Ecoradiological Centre Model is studied in some detail for the town of Kotor which is under the protection of the World Cultural and Natural Heritage. The proposed structure of the Centre is analyzed from the view of Engineering, Education and Scientific parameters. This Model is suitable for implementation as a network Centre Model for the state of Montenegro. Further, the modelling strategy of the ecoradiological condition control of natural, construction, bio and technological systems is elaborated. The proposal includes the ecoradiological monitoring, radioactive and electromagnetic radiation processing and protection for different natural zones as well as their different geostructures, aerial and hydrogeological conditions. The programme also includes all housing objects (hotels, flats, houses, office premises etc.). Here will also be presented the radiation protection and recommendations for the implementation of Title VII of the European Basic Safety Standards Directive (BSS), concerning significant increase in exposure due to natural radiation sources. Also, the proposal of Local Radiation Protection for the town of Kotor is presented. Our proposal for an Ecoradiological Centre Model presented here is in a form of a pilot programme, applicable also for other towns and states. (author)

  19. A proposed general model of information behaviour.

    Directory of Open Access Journals (Sweden)

    2003-01-01

    Full Text Available Presents a critical description of Wilson's (1996 global model of information behaviour and proposes major modification on the basis of research into information behaviour of managers, conducted in Poland. The theoretical analysis and research results suggest that Wilson's model has certain imperfections, both in its conceptual content, and in graphical presentation. The model, for example, cannot be used to describe managers' information behaviour, since managers basically are not the end users of external from organization or computerized information services, and they acquire information mainly through various intermediaries. Therefore, the model cannot be considered as a general model, applicable to every category of information users. The proposed new model encompasses the main concepts of Wilson's model, such as: person-in-context, three categories of intervening variables (individual, social and environmental, activating mechanisms, cyclic character of information behaviours, and the adoption of a multidisciplinary approach to explain them. However, the new model introduces several changes. They include: 1. identification of 'context' with the intervening variables; 2. immersion of the chain of information behaviour in the 'context', to indicate that the context variables influence behaviour at all stages of the process (identification of needs, looking for information, processing and using it; 3. stress is put on the fact that the activating mechanisms also can occur at all stages of the information acquisition process; 4. introduction of two basic strategies of looking for information: personally and/or using various intermediaries.

  20. A proposed experiment on ball lightning model

    International Nuclear Information System (INIS)

    Ignatovich, Vladimir K.; Ignatovich, Filipp V.

    2011-01-01

    Highlights: → We propose to put a glass sphere inside an excited gas. → Then to put a light ray inside the glass in a whispering gallery mode. → If the light is resonant to gas excitation, it will be amplified at every reflection. → In ms time the light in the glass will be amplified, and will melt the glass. → A liquid shell kept integer by electrostriction forces is the ball lightning model. -- Abstract: We propose an experiment for strong light amplification at multiple total reflections from active gaseous media.

  1. Apparatus and method for gaining the whole information content of radiographic pictures

    International Nuclear Information System (INIS)

    Sasdi, A.

    1978-01-01

    Methods for depth size determination of welding errors from radiographic films are reviewed. Based on information theory the processes of exposure, development and evaluation were studied. The density function of the radiographic film is considered to be the critical filter of the system. A model of a high resolution electronic density meter is introduced. The nonlinearity of the density function was compensated by electronic filtering. The development of a new type radiographic instrument using video technique is proposed. (R.J.)

  2. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  3. Media Accountability Systems: Models, proposals and outlooks

    Directory of Open Access Journals (Sweden)

    Luiz Martins da Silva

    2007-06-01

    Full Text Available This paper analyzes one of the basic actions of SOS-Imprensa, the mechanism to assure Media Accountability with the goal of proposing a synthesis of models for the Brazilian reality. The article aims to address the possibilities of creating and improving mechanisms to stimulate the democratic press process and to mark out and assure freedom of speech and personal rights with respect to the media. Based on the Press Social Responsibility Theory, the hypothesis is that the experiences analyzed (Communication Council, Press Council, Ombudsman and Readers Council are alternatives for accountability, mediation and arbitration, seeking visibility, trust and public support in favor of fairer media.

  4. A Proposed Conceptual Model of Military Medical Readiness

    National Research Council Canada - National Science Library

    Van Hall, Brian M

    2007-01-01

    .... The basis for the proposed conceptual model builds on common and accepted latent variable and theoretical modeling techniques proposed by healthcare scholars, organizational theorists, mathematical...

  5. The 'OMITRON' and 'MODEL OMITRON' proposed experiments

    International Nuclear Information System (INIS)

    Sestero, A.

    1997-12-01

    In the present paper the main features of the OMITRON and MODEL OMITRON proposed high field tokamaks are illustrated. Of the two, OMITRON is an ambitious experiment, aimed at attaining plasma burning conditions. its key physics issues are discussed, and a comparison is carried out with corresponding physics features in ignition experiments such as IGNITOR and ITER. Chief asset and chief challenge - in both OMITRON and MODEL OMITRON is the conspicuous 20 Tesla toroidal field value on the plasma axis. The advanced features of engineering which consent such a reward in terms of toroidal magnet performance are discussed in convenient depth and detail. As for the small, propaedeutic device MODEL OMITRON among its goals one must rank the purpose of testing key engineering issues in vivo, which are vital for the larger and more expensive parent device. Besides that, however - as indicated by ad hoc performed scoping studies - the smaller machine is found capable also of a number of quite interesting physics investigations in its own right

  6. Performance of a Deep-Learning Neural Network Model in Assessing Skeletal Maturity on Pediatric Hand Radiographs.

    Science.gov (United States)

    Larson, David B; Chen, Matthew C; Lungren, Matthew P; Halabi, Safwan S; Stence, Nicholas V; Langlotz, Curtis P

    2018-04-01

    Purpose To compare the performance of a deep-learning bone age assessment model based on hand radiographs with that of expert radiologists and that of existing automated models. Materials and Methods The institutional review board approved the study. A total of 14 036 clinical hand radiographs and corresponding reports were obtained from two children's hospitals to train and validate the model. For the first test set, composed of 200 examinations, the mean of bone age estimates from the clinical report and three additional human reviewers was used as the reference standard. Overall model performance was assessed by comparing the root mean square (RMS) and mean absolute difference (MAD) between the model estimates and the reference standard bone ages. Ninety-five percent limits of agreement were calculated in a pairwise fashion for all reviewers and the model. The RMS of a second test set composed of 913 examinations from the publicly available Digital Hand Atlas was compared with published reports of an existing automated model. Results The mean difference between bone age estimates of the model and of the reviewers was 0 years, with a mean RMS and MAD of 0.63 and 0.50 years, respectively. The estimates of the model, the clinical report, and the three reviewers were within the 95% limits of agreement. RMS for the Digital Hand Atlas data set was 0.73 years, compared with 0.61 years of a previously reported model. Conclusion A deep-learning convolutional neural network model can estimate skeletal maturity with accuracy similar to that of an expert radiologist and to that of existing automated models. © RSNA, 2017 An earlier incorrect version of this article appeared online. This article was corrected on January 19, 2018.

  7. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  8. 3D reconstruction of a patient-specific surface model of the proximal femur from calibrated x-ray radiographs: A validation study

    International Nuclear Information System (INIS)

    Zheng Guoyan; Schumann, Steffen

    2009-01-01

    Twenty-three femurs (one plastic bone and twenty-two cadaver bones) with both nonpathologic and pathologic cases were considered to validate a statistical shape model based technique for three-dimensional (3D) reconstruction of a patient-specific surface model from calibrated x-ray radiographs. The 3D reconstruction technique is based on an iterative nonrigid registration of the features extracted from a statistically instantiated 3D surface model to those interactively identified from the radiographs. The surface models reconstructed from the radiographs were compared to the associated ground truths derived either from a 3D CT-scan reconstruction method or from a 3D laser-scan reconstruction method and an average error distance of 0.95 mm were found. Compared to the existing works, our approach has the advantage of seamlessly handling both nonpathologic and pathologic cases even when the statistical shape model that we used was constructed from surface models of nonpathologic bones.

  9. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    International Nuclear Information System (INIS)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A.

    2018-01-01

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  10. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A. [Hadassah Hebrew University Hospital, Department of Orthopaedics, Jerusalem (Israel)

    2018-04-15

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  11. Use of statistical models based on radiographic measurements to predict oviposition date and clutch size in rock iguanas (Cyclura nubila)

    International Nuclear Information System (INIS)

    Alberts, A.C.

    1995-01-01

    The ability to noninvasively estimate clutch size and predict oviposition date in reptiles can be useful not only to veterinary clinicians but also to managers of captive collections and field researchers. Measurements of egg size and shape, as well as position of the clutch within the coelomic cavity, were taken from diagnostic radiographs of 20 female Cuban rock iguanas, Cyclura nubila, 81 to 18 days prior to laying. Combined with data on maternal body size, these variables were entered into multiple regression models to predict clutch size and timing of egg laying. The model for clutch size was accurate to 0.53 ± 0.08 eggs, while the model for oviposition date was accurate to 6.22 ± 0.81 days. Equations were generated that should be applicable to this and other large Cyclura species. © 1995 Wiley-Liss, Inc

  12. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  13. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  14. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  15. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2012-01-01

    the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees.

  16. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  17. Child-Labor Proposal Eyes Private Model

    Science.gov (United States)

    Cech, Scott J.

    2007-01-01

    Proposed child-labor-rule changes--the most ambitious in 30 years--would carve out a permanent exemption to U.S. Department of Labor regulations for the work-study program run by a national network of Roman Catholic high schools. The program is a requirement of the Chicago-based Cristo Rey Network, which now has 12 high schools around the country…

  18. Alveolar bone-loss area localization in periodontitis radiographs based on threshold segmentation with a hybrid feature fused of intensity and the H-value of fractional Brownian motion model.

    Science.gov (United States)

    Lin, P L; Huang, P W; Huang, P Y; Hsu, H C

    2015-10-01

    Periodontitis involves progressive loss of alveolar bone around the teeth. Hence, automatic alveolar bone-loss (ABL) measurement in periapical radiographs can assist dentists in diagnosing such disease. In this paper, we propose an effective method for ABL area localization and denote it as ABLIfBm. ABLIfBm is a threshold segmentation method that uses a hybrid feature fused of both intensity and texture measured by the H-value of fractional Brownian motion (fBm) model, where the H-value is the Hurst coefficient in the expectation function of a fBm curve (intensity change) and is directly related to the value of fractal dimension. Adopting leave-one-out cross validation training and testing mechanism, ABLIfBm trains weights for both features using Bayesian classifier and transforms the radiograph image into a feature image obtained from a weighted average of both features. Finally, by Otsu's thresholding, it segments the feature image into normal and bone-loss regions. Experimental results on 31 periodontitis radiograph images in terms of mean true positive fraction and false positive fraction are about 92.5% and 14.0%, respectively, where the ground truth is provided by a dentist. The results also demonstrate that ABLIfBm outperforms (a) the threshold segmentation method using either feature alone or a weighted average of the same two features but with weights trained differently; (b) a level set segmentation method presented earlier in literature; and (c) segmentation methods based on Bayesian, K-NN, or SVM classifier using the same two features. Our results suggest that the proposed method can effectively localize alveolar bone-loss areas in periodontitis radiograph images and hence would be useful for dentists in evaluating degree of bone-loss for periodontitis patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Automatic segmentation of vertebrae from radiographs

    DEFF Research Database (Denmark)

    Mysling, Peter; Petersen, Peter Kersten; Nielsen, Mads

    2011-01-01

    Segmentation of vertebral contours is an essential task in the design of automatic tools for vertebral fracture assessment. In this paper, we propose a novel segmentation technique which does not require operator interaction. The proposed technique solves the segmentation problem in a hierarchical...... is constrained by a conditional shape model, based on the variability of the coarse spine location estimates. The technique is evaluated on a data set of manually annotated lumbar radiographs. The results compare favorably to the previous work in automatic vertebra segmentation, in terms of both segmentation...

  20. A Proposed Curriculum Model for Geriatric Optometry.

    Science.gov (United States)

    Rosenbloom, Albert A.

    1985-01-01

    A model for a geriatric optometry curriculum that defines key content areas and addresses the values essential for effective practice and basic therapeutic modalities used in treatment regimens with older adults is outlined. (MSE)

  1. A proposed model for construction project management ...

    African Journals Online (AJOL)

    Keywords: Communication skills and leadership model, construction project ..... help a manager handle stress and break tension (Gido & Clements,. 2012: 331; Harrin .... production and management of projects, the higher the demand for.

  2. A proposed model for construction project management ...

    African Journals Online (AJOL)

    Log in or Register to get access to full text downloads. ... (decision-making, problem-solving, listening, verbal competency, motivation, persuasion, ... Keywords: Communication skills and leadership model, construction project management, ...

  3. Statistical shape model-based reconstruction of a scaled, patient-specific surface model of the pelvis from a single standard AP x-ray radiograph

    Energy Technology Data Exchange (ETDEWEB)

    Zheng Guoyan [Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern (Switzerland)

    2010-04-15

    Purpose: The aim of this article is to investigate the feasibility of using a statistical shape model (SSM)-based reconstruction technique to derive a scaled, patient-specific surface model of the pelvis from a single standard anteroposterior (AP) x-ray radiograph and the feasibility of estimating the scale of the reconstructed surface model by performing a surface-based 3D/3D matching. Methods: Data sets of 14 pelvises (one plastic bone, 12 cadavers, and one patient) were used to validate the single-image based reconstruction technique. This reconstruction technique is based on a hybrid 2D/3D deformable registration process combining a landmark-to-ray registration with a SSM-based 2D/3D reconstruction. The landmark-to-ray registration was used to find an initial scale and an initial rigid transformation between the x-ray image and the SSM. The estimated scale and rigid transformation were used to initialize the SSM-based 2D/3D reconstruction. The optimal reconstruction was then achieved in three stages by iteratively matching the projections of the apparent contours extracted from a 3D model derived from the SSM to the image contours extracted from the x-ray radiograph: Iterative affine registration, statistical instantiation, and iterative regularized shape deformation. The image contours are first detected by using a semiautomatic segmentation tool based on the Livewire algorithm and then approximated by a set of sparse dominant points that are adaptively sampled from the detected contours. The unknown scales of the reconstructed models were estimated by performing a surface-based 3D/3D matching between the reconstructed models and the associated ground truth models that were derived from a CT-based reconstruction method. Such a matching also allowed for computing the errors between the reconstructed models and the associated ground truth models. Results: The technique could reconstruct the surface models of all 14 pelvises directly from the landmark

  4. Model-based wear measurements in total knee arthroplasty : development and validation of novel radiographic techniques

    NARCIS (Netherlands)

    IJsseldijk, van E.A.

    2016-01-01

    The primary aim of this work was to develop novel model-based mJSW measurement methods using a 3D reconstruction and compare the accuracy and precision of these methods to conventional mJSW measurement. This thesis contributed to the development, validation and clinical application of model-based

  5. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  6. A Proposal for a Flexible Trend Specification in DSGE Models

    Directory of Open Access Journals (Sweden)

    Slanicay Martin

    2016-06-01

    Full Text Available In this paper I propose a flexible trend specification for estimating DSGE models on log differences. I demonstrate this flexible trend specification on a New Keynesian DSGE model of two economies, which I consequently estimate on data from the Czech economy and the euro area, using Bayesian techniques. The advantage of the trend specification proposed is that the trend component and the cyclical component are modelled jointly in a single model. The proposed trend specification is flexible in the sense that smoothness of the trend can be easily modified by different calibration of some of the trend parameters. The results suggest that this method is capable of finding a very reasonable trend in the data. Moreover, comparison of forecast performance reveals that the proposed specification offers more reliable forecasts than the original variant of the model.

  7. A Proposed Systems Model for Socializing the Graduate Writer

    Science.gov (United States)

    Jones, David R.

    2018-01-01

    Although researchers chorus the need to support graduate students toward higher levels of writing proficiency, their findings lack a holistic model for doing so. A model emerges upon scrutiny of the factors that have been implicated in supporting writing proficiency. In the proposed model, a socialization theory fits as a proximal process into the…

  8. A proposed best practice model validation framework for banks

    Directory of Open Access Journals (Sweden)

    Pieter J. (Riaan de Jongh

    2017-06-01

    Full Text Available Background: With the increasing use of complex quantitative models in applications throughout the financial world, model risk has become a major concern. The credit crisis of 2008–2009 provoked added concern about the use of models in finance. Measuring and managing model risk has subsequently come under scrutiny from regulators, supervisors, banks and other financial institutions. Regulatory guidance indicates that meticulous monitoring of all phases of model development and implementation is required to mitigate this risk. Considerable resources must be mobilised for this purpose. The exercise must embrace model development, assembly, implementation, validation and effective governance. Setting: Model validation practices are generally patchy, disparate and sometimes contradictory, and although the Basel Accord and some regulatory authorities have attempted to establish guiding principles, no definite set of global standards exists. Aim: Assessing the available literature for the best validation practices. Methods: This comprehensive literature study provided a background to the complexities of effective model management and focussed on model validation as a component of model risk management. Results: We propose a coherent ‘best practice’ framework for model validation. Scorecard tools are also presented to evaluate if the proposed best practice model validation framework has been adequately assembled and implemented. Conclusion: The proposed best practice model validation framework is designed to assist firms in the construction of an effective, robust and fully compliant model validation programme and comprises three principal elements: model validation governance, policy and process.

  9. A Proposed Conceptual Model of Military Medical Readiness

    National Research Council Canada - National Science Library

    Van Hall, Brian M

    2007-01-01

    .... The purpose of this research is to consolidate existing literature on the latent variable of medical readiness, and to propose a composite theoretical model of medical readiness that may provide...

  10. Linear regression crash prediction models : issues and proposed solutions.

    Science.gov (United States)

    2010-05-01

    The paper develops a linear regression model approach that can be applied to : crash data to predict vehicle crashes. The proposed approach involves novice data aggregation : to satisfy linear regression assumptions; namely error structure normality ...

  11. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  12. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  13. Gamification in online education: proposal for a participatory learning model

    Directory of Open Access Journals (Sweden)

    Fabiana Bigão Silva

    2017-09-01

    Full Text Available Empirical studies have suggested limitations on the form of application of gamification mechanics in the context of online education. These mechanics have been applied without reference to a theoretical model dedicated to this type of education. The objective of the paper is to propose a model for a gamified platform for online education that contributes to a more participatory learning, taking into account the different student profiles. Based on literature review about approaches to gamification systems design, a set of steps was followed in order to develop a generic model for a framework dedicated to online education. The model proposed is based on the Educational Gamification Design Principles proposed by Dicheva et al. (2015. The model may contribute to the promotion of participatory learning, taking into account the different student profiles. The results of such evaluation will be published in the future.

  14. A Modified Microfinance Model Proposed for the United States

    Directory of Open Access Journals (Sweden)

    Eldon H Bernstein

    2014-07-01

    While the goal in the traditional model in developing markets is the elimination of poverty, we show how those critical conditions help to explain the lack of success in the United States.  We propose a modified model whose goal is the creation of an entrepreneurial venture or improving the performance of an existing small enterprise.

  15. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  16. Proposal for product development model focused on ce certification methodology

    Directory of Open Access Journals (Sweden)

    Nathalia Marcia Goulart Pinheiro

    2015-09-01

    Full Text Available This paper presents a critical analysis comparing 21 product development models in order to identify whether these structures meet the demands Product Certification of the European Community (CE. Furthermore, it presents a product development model, comprising the steps in the models analyzed, including improvements in activities for referred product certification. The proposed improvements are justified by the growing quest for the internationalization of products and processes within companies.

  17. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  18. A proposed residual stress model for oblique turning

    International Nuclear Information System (INIS)

    Elkhabeery, M. M.

    2001-01-01

    A proposed mathematical model is presented for predicting the residual stresses caused by turning. Effects of change in tool free length, cutting speed, feed rate, and the tensile strength of work piece material on the maximum residual stress are investigated. The residual stress distribution in the surface region due to turning under unlubricated condition is determined using a deflection etching technique. To reduce the number of experiments required and build the mathematical model for these variables, Response Surface Methodology (RSM) is used. In addition, variance analysis and an experimental check are conducted to determine the prominent parameters and the adequacy of the model. The results show that the tensile stress of the work piece material, cutting speed, and feed rate have significant effects on the maximum residual stresses. The proposed model, that offering good correlation between the experimental and predicted results, is useful in selecting suitable cutting parameters for the machining of different materials. (author)

  19. Main features of the proposed NCRP respiratory tract model

    International Nuclear Information System (INIS)

    Phalen, R.F.; Fisher, G.L.; Moss, O.R.; Schlesinger, R.B.; Swift, D.L.

    1991-01-01

    The proposed NCRP respiratory tract dosimetry model regions include the naso-oro-pharyngo-laryngeal (NOPL), the tracheobronchial (TB), the pulmonary (P), and the lymph nodes (LN). Input aerosol concentrations are derived from a consideration of particle-size-dependent inspirability. Particle deposition in the respiratory tract is modelled using the mechanisms of inertial impaction, sedimentation and diffusion. The rates of absorption of particles, and transport to the blood, have been derived from clearance data from people and laboratory animals. The effect of body growth on particle deposition is considered. Particle clearance rates are assumed to be independent of age. The proposed respiratory tract model differs significantly from the 1966 Task Group Model in that (1) inspirability is considered; (2) new sub-regions of the respiratory tract are considered; (3) absorption of materials by the blood is treated in a more sophisticated fashion; and (4) body size (and thus age) is taken into account. (author)

  20. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  1. Proposed higher order continuum-based models for an elastic ...

    African Journals Online (AJOL)

    Three new variants of continuum-based models for an elastic subgrade are proposed. The subgrade is idealized as a homogenous, isotropic elastic layer of thickness H overlying a firm stratum. All components of the stress tensor in the subgrade are taken into account. Reasonable assumptions are made regarding the ...

  2. A Proposed Model of Jazz Theory Knowledge Acquisition

    Science.gov (United States)

    Ciorba, Charles R.; Russell, Brian E.

    2014-01-01

    The purpose of this study was to test a hypothesized model that proposes a causal relationship between motivation and academic achievement on the acquisition of jazz theory knowledge. A reliability analysis of the latent variables ranged from 0.92 to 0.94. Confirmatory factor analyses of the motivation (standardized root mean square residual…

  3. Proposal of a theoretical model for the practical nurse

    Directory of Open Access Journals (Sweden)

    Dolores Abril Sabater

    2010-01-01

    Full Text Available AIM: To determine which model of nursing is proposed by care professionals and the reason for their choice. METHOD: cross-sectional, descriptive study design. The main variable: Nursing Models and Theories. As secondary variables were collected: age, gender, years of work experience, nursing model of basic training, and course/s related. We used a self-elaborated, anonymous questionnaire, passed between April - May, 2006. Not random sample.RESULTS: 546 nurses were invited, answered 205. 38 % response rate. Virginia Henderson was the more selected model (33%, however, 42% left the question blank, 12% indicated that they wanted to work under the guidance of a model. They selected a specifically model: Knowledge of the model to their training, standardization in other centers, the characteristics of the model itself and identification with its philosophy. They are not decided by a model by ignorance, lack of time and usefulness. CONCLUSIONS: The model chosen mostly for their daily work was Virginia Henderson model, so that knowledge of a model is the main reason for their election. Professionals who choose not to use the model in their practice realize offers and calling for resources, besides to explain the lack of knowledge on this topic. To advance the nursing profession is necessary that nurse is thought over widely on the abstract concepts of the theory in our context.

  4. Model-Based Least Squares Reconstruction of Coded Source Neutron Radiographs: Integrating the ORNL HFIR CG1D Source Model

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Gregor, Jens [University of Tennessee, Knoxville (UTK); Bingham, Philip R [ORNL

    2014-01-01

    At the present, neutron sources cannot be fabricated small and powerful enough in order to achieve high resolution radiography while maintaining an adequate flux. One solution is to employ computational imaging techniques such as a Magnified Coded Source Imaging (CSI) system. A coded-mask is placed between the neutron source and the object. The system resolution is increased by reducing the size of the mask holes and the flux is increased by increasing the size of the coded-mask and/or the number of holes. One limitation of such system is that the resolution of current state-of-the-art scintillator-based detectors caps around 50um. To overcome this challenge, the coded-mask and object are magnified by making the distance from the coded-mask to the object much smaller than the distance from object to detector. In previous work, we have shown via synthetic experiments that our least squares method outperforms other methods in image quality and reconstruction precision because of the modeling of the CSI system components. However, the validation experiments were limited to simplistic neutron sources. In this work, we aim to model the flux distribution of a real neutron source and incorporate such a model in our least squares computational system. We provide a full description of the methodology used to characterize the neutron source and validate the method with synthetic experiments.

  5. Bayesian inference of chemical kinetic models from proposed reactions

    KAUST Repository

    Galagali, Nikhil

    2015-02-01

    © 2014 Elsevier Ltd. Bayesian inference provides a natural framework for combining experimental data with prior knowledge to develop chemical kinetic models and quantify the associated uncertainties, not only in parameter values but also in model structure. Most existing applications of Bayesian model selection methods to chemical kinetics have been limited to comparisons among a small set of models, however. The significant computational cost of evaluating posterior model probabilities renders traditional Bayesian methods infeasible when the model space becomes large. We present a new framework for tractable Bayesian model inference and uncertainty quantification using a large number of systematically generated model hypotheses. The approach involves imposing point-mass mixture priors over rate constants and exploring the resulting posterior distribution using an adaptive Markov chain Monte Carlo method. The posterior samples are used to identify plausible models, to quantify rate constant uncertainties, and to extract key diagnostic information about model structure-such as the reactions and operating pathways most strongly supported by the data. We provide numerical demonstrations of the proposed framework by inferring kinetic models for catalytic steam and dry reforming of methane using available experimental data.

  6. Consultant radiographer leadership - A discussion

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter [Directorate of Radiography, University of Salford, Allerton Building, Frederick Road, Salford, Greater Manchester M6 6PU (United Kingdom)], E-mail: p.hogg@salford.ac.uk; Hogg, Dianne [Henwood Associates (South East) Ltd, Company Number: 513796, Registered Office: 2 Lakeview Stables, Lower St Clere, Kemsing, Kent, TN15 6NL (United Kingdom); Henwood, Suzanne [East Lancashire Primary Care Trust, Linden Business Centre, Linden Road, Colne. BB8 9BA (United Kingdom)

    2008-12-15

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills.

  7. Tacit knowledge in academia: a proposed model and measurement scale.

    Science.gov (United States)

    Leonard, Nancy; Insch, Gary S

    2005-11-01

    The authors propose a multidimensional model of tacit knowledge and develop a measure of tacit knowledge in academia. They discuss the theory and extant literature on tacit knowledge and propose a 6-factor model. Experiment 1 is a replication of a recent study of academic tacit knowledge using the scale developed and administered at an Israeli university (A. Somech & R. Bogler, 1999). The results of the replication differed from those found in the original study. For Experiment 2, the authors developed a domain-specific measure of academic tacit knowledge, the Academic Tacit Knowledge Scale (ATKS), and used this measure to explore the multidimensionality of tacit knowledge proposed in the model. The results of an exploratory factor analysis (n=142) followed by a confirmatory factor analysis (n=286) are reported. The sample for both experiments was 428 undergraduate students enrolled at a large public university in the eastern United States. Results indicated that a 5-factor model of academic tacit knowledge provided a strong fit for the data.

  8. Proposal of a new biokinetic model for niobium

    International Nuclear Information System (INIS)

    Oliveira, Roges

    2006-01-01

    There are two niobium isotopes generated in nuclear power plants: 95 Nb and 94 Nb. Workers and members of the public are subjects to intake these radionuclides in accident situation. For dose calculation purpose, it is very important to develop a model that describes in a more realistic way the kinetics of niobium inside of the human body. Presently the model adopted by ICRP (ICRP, 1989) is based on animal studies and describes the behavior of niobium in human being in a simple manner. The new model proposal describes the kinetics of the niobium from the intake into the blood until the excretion, doing this in a more realistic form and considering not only data from animals but data from human beings as well. For this objective, a workers group of a niobium extraction and processing industry exposed to stable niobium (93 Nb) in oxide insoluble form with associated uranium, was monitored for uranium and niobium determination in urinary and fecal excretion, by mass spectrometry. Based in the ratios of the niobium concentration in urinary and faecal excretion of this workers and animal data study, a new biokinetic model for niobium was proposed, with the followings modifications relative to ICRP model: a new compartment that represents muscular tissue; the fractions which are deposited into the compartment are modified; a third component in the retention equation of the bone tissue; introduction of recirculation between organs and blood. The new model was applied for a case of accidental intake and described adequately the experimental data

  9. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  10. Dose, image quality and spine modeling assessment of biplanar EOS micro-dose radiographs for the follow-up of in-brace adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Morel, Baptiste; Moueddeb, Sonia; Blondiaux, Eleonore; Richard, Stephen; Bachy, Manon; Vialle, Raphael; Ducou Le Pointe, Hubert

    2018-05-01

    The aim of this study was to compare the radiation dose, image quality and 3D spine parameter measurements of EOS low-dose and micro-dose protocols for in-brace adolescent idiopathic scoliosis (AIS) patients. We prospectively included 25 consecutive patients (20 females, 5 males) followed for AIS and undergoing brace treatment. The mean age was 12 years (SD 2 years, range 8-15 years). For each patient, in-brace biplanar EOS radiographs were acquired in a standing position using both the conventional low-dose and micro-dose protocols. Dose area product (DAP) was systematically recorded. Diagnostic image quality was qualitatively assessed by two radiologists for visibility of anatomical structures. The reliability of 3D spine modeling between two operators was quantitatively evaluated for the most clinically relevant 3D radiological parameters using intraclass correlation coefficient (ICC). The mean DAP for the posteroanterior and lateral acquisitions was 300 ± 134 and 433 ± 181 mGy cm 2 for the low-dose radiographs, and 41 ± 19 and 81 ± 39 mGy cm 2 for micro-dose radiographs. Image quality was lower with the micro-dose protocol. The agreement was "good" to "very good" for all measured clinical parameters when comparing the low-dose and micro-dose protocols (ICC > 0.73). The micro-dose protocol substantially reduced the delivered dose (by a factor of 5-7 compared to the low-dose protocol) in braced children with AIS. Although image quality was reduced, the micro-dose protocol proved to be adapted to radiological follow-up, with adequate image quality and reliable clinical measurements. These slides can be retrieved under Electronic Supplementary Material.

  11. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  12. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  13. The Associative Basis of Scientific Creativity: A Model Proposal

    Directory of Open Access Journals (Sweden)

    Esra Kanli

    2014-06-01

    Full Text Available Creativity is accepted as an important part of scientific skills. Scientific creativity proceeds from a need or urge to solve a problem, and in-volves the production of original and useful ideas or products. Existing scientific creativity theories and tests do not feature the very im-portant thinking processes, such as analogical and associative thinking, which can be consid-ered crucial in creative scientific problem solv-ing. Current study’s aim is to provide an alter-native model and explicate the associative basis of scientific creativity. Emerging from the re-viewed theoretical framework, Scientific Asso-ciations Model is proposed. This model claims that, similarity and mediation constitutes the basis of creativity and focuses on three compo-nents namely; associative thinking, analogical thinking (analogical reasoning & analogical problem solving and insight which are consid-ered to be main elements of scientific associa-tive thinking.

  14. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  15. PROPOSAL OF A MODEL MANAGEMENT TO SMALL DESIGN COMPANIES

    Directory of Open Access Journals (Sweden)

    Otávio José de OLIVEIRA

    2008-11-01

    Full Text Available The main purpose of this paper is the proposition of a management model specifically developed for small building design firms, aligned with their needs and particularities. The field research was conducted with a qualitative approach through the analysis of four case studies in small building design firms acting mainly in São Paulo City. The data collection was accomplished through semi-structured interviews, direct observation and analysis of documents. The proposed model includes guidance to the management of the core processes and activities of small building design firms, such as: organizational structure; strategic planning; planning and control of design process; costs management; sales management; information systems; human resources management; services added to the design; and performance evaluation. Key-words: design firms; design process; building construction.

  16. Sensitometric curve of radiographic films by X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, E.A.S., E-mail: elicardo.goncalves@ifrj.edu.br [Instituto Federal do Rio de Janeiro (IFRJ), RJ (Brazil); Oliveira, D.F.; Anjos, M.J. dos; Oliveira, L.F. de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Lopes, R.T. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radiographic film exposure is traditionally measured by the transmittance of a beam of light through the film. There are many mathematical and computational models to characterize the curve behavior and its properties, but almost none of them considers the limitations caused by the equipment used. As long as exposure in film increases, light intensity measured after the film decreases in a way that from a certain exposure, light could not be distinguished from any kind of noise. This work aims to propose x-ray fluorescence as a solution for better measure high exposed films and show how it could be modeled mathematically. (author)

  17. Patent portfolio management: literature review and a proposed model.

    Science.gov (United States)

    Conegundes De Jesus, Camila Kiyomi; Salerno, Mario Sergio

    2018-05-09

    Patents and patent portfolios are gaining attention in the last decades, from the called 'pro-patent era' to the recent billionaire transactions involving patent portfolios. The field is growing in importance, both theoretically and practically and despite having substantial literature on new product development portfolio management, we have not found an article relating this theory to patent portfolios. Areas covered: The paper develops a systematic literature review on patent portfolio management to organize the evolution and tendencies of patent portfolio management, highlighting distinctive features of patent portfolio management. Interview with IP manager of three life sciences companies, including a leading multinational group provided relevant information about patent portfolio management. Expert opinion: Based on the systematic literature review on portfolio management, more specifically, on new product development portfolio theory, and interview the paper proposes the paper proposes a reference model to manage patent portfolios. The model comprises four stages aligned with the three goals of the NPD portfolio management: 1 - Linking strategy of the Company's NPD Portfolio to Patent Portfolio; 2 - Balancing the portfolio in buckets; 3 - Patent Valuation (maximizing valuation); 4 - Regularly reviewing the patent portfolio.

  18. The evaluation of doctoral thesis. A model proposal

    Directory of Open Access Journals (Sweden)

    de-Miguel, Mario

    2010-04-01

    Full Text Available The aim of this work is the development of a model that can be used as a framework for evaluators and PhD tribunal members, either during the previous administrative processing phase or at the actual exposition and viva on doctoral dissertations. To this end, once reviewed the existing literature and normative, a new proposal is laid out on the main aspects and criteria to be analysed and assessed from any given scientific work, thus introducing a tool that facilitates and specifies this work. Our model is intended to be an open proposal on which we would welcome any contribution and suggestion. El objetivo del presente trabajo es la elaboración de un modelo que pueda ser utilizado como marco de referencia por los evaluadores y miembros de tribunales de las tesis doctorales tanto en la fase previa a la tramitación administrativa como en el acto de exposición y defensa de la misma. Para ello, una vez revisada la literatura y la normativa vigente al respecto, efectuamos una propuesta sobre los principales aspectos y criterios que deben ser objeto de análisis y valoración en todo trabajo científico, y presentamos una herramienta que facilita y precisa esta tarea. Nuestro modelo constituye una propuesta abierta sobre la que esperamos aportaciones y sugerencias.

  19. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR “DIE PUNCH” DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2015-01-01

    Objective: the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. Methods: There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. Results: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. Conclusion: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. PMID:27027079

  20. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  1. "The Actualized Neurosurgeon": A Proposed Model of Surgical Resident Development.

    Science.gov (United States)

    Lipsman, Nir; Khan, Osaama; Kulkarni, Abhaya V

    2017-03-01

    Modern neurosurgical training is both physically and emotionally demanding, posing significant challenges, new and old, to residents as well as programs attempting to train safe, competent surgeons. Models to describe resident development, such as the Accreditation Council for Graduate Medical Education competencies and milestones, address the acquisition of specific skills but largely ignore the stresses and pressures unique to each stage of resident training. We propose an alternative model of resident development adapted from the developmental psychology literature. Our model identifies the challenges that must be met at each stage of junior, intermediate, and senior and chief residency, leading ultimately to an "actualized" neurosurgeon (i.e., one who has maximized his or her potential). Failure to overcome any 1 of these challenges can lead to specific long-lasting consequences, including regret, identity crisis, incompetence, and bitterness. In contrast, the actualized surgeon is one who has successfully acquired the virtues of hope, will, purpose, fidelity, productivity, leadership, competence, and wisdom. The actualized surgeon not only functions safely, confidently, and professionally, but also successfully navigates the challenges of residency and emerges from them having fulfilled his or her maximal potential. This developmental perspective provides an individualized description of healthy surgical development. Our model allows programs to identify the basis for residents who fail to progress, counsel residents during their training, and perhaps help identify resident candidates who are better prepared to meet the developmental challenges of residency training. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Radiographic detection of single-leg fracture in Björk-Shiley Convexo-Concave prosthetic valves: a phantom model study.

    Science.gov (United States)

    Gilchrist, I C; Cardella, J F; Fox, P S; Pae, W E; el-Ghamry Sabe, A A; Landis, J R; Localio, A R; Kunselman, A R; Hopper, K D

    1997-02-01

    Cineradiography can identify patients with single-leg fractured Björk-Shiley Convexo-Concave valves, although little is known about the sensitivity and specificity of this technique. We evaluated three normal and six (0 microm gap) single-leg fractured Björk-Shiley valves that were placed in a working phantom model. Valves were randomly imaged a total of 33 times and duplicated into a 120-valve series with a 1:9 ratio of abnormal/normal valves. Six reviewers independently graded each valve and demonstrated markedly different rates of identifying the fractured valves. Average sensitivity at the grade that clinically results in valve explanation was 47%. Among the normal valves, a correct identification was made 96% (range 91% to 99%) of the time. Present radiographic technology may have significant difficulty in identifying true single-leg fracture in Björk-Shiley valves with limb separations that are common among clinically explanted valves.

  3. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    Science.gov (United States)

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  4. Modeling Instruction of David Hestenes: a proposal of thematic modeling cycle and discussion of scientific literacy

    Directory of Open Access Journals (Sweden)

    Ednilson Sergio Ramalho de Souza

    2016-07-01

    Full Text Available The pedagogical work with mathematical modeling assumes investigate situations of reality. However, mental models formed from the contact with the experiential world are generally incompatible with the conceptual models. So David Hestenes supports the view that one of the biggest challenges of teaching and learning in science and mathematics is to coordinate conceptual models with mental models, which led to the elaboration of a didactic in mathematical modeling: Modeling Instruction. Our goal is to present a proposal for thematic modeling cycle drawn up in hestenesianos assumptions and discuss possibilities for scientific literacy. The main question was to know how to emerge indicators for scientific literacy for the proposed cycle. This is a bibliographic research in order to identify the available literature contributions on the subject and raise the possibility and challenges for the brazilian teaching science and mathematics. Preliminary results indicate that the proposed modeling cycle can develop indicators for scientific literacy of different natures.

  5. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  6. Proposal of a pedagogical model for mathematics teacher education

    Directory of Open Access Journals (Sweden)

    Alfonso Jiménez Espinosa

    2011-01-01

    Full Text Available This research-based article reflects on mathematics teacher education, and proposes a pedagogical model for this purpose, called Gradual Research Pedagogical Model (MPGI. This model considers the central curricular elements of any academic education process: student, teacher and contents, with evaluation as transversal element for analysis and feedback. The training of future teachers is constituted by three moments, each with its specific emphasis: the first is “contextualization”, which aims at having the student understand his or her new academic role, and identify and overcome his or her academic weak points, the second is “knowledge foundation”, which offers basic education in the fields of mathematics and pedagogy, as well as sensibilization towards social issues, opening up the student’s possibilities as leader and agent of change, and lastly, “knowledge immersion”, which is centered on research and the identification and study of topics and problems of the mathematical discipline as well as the pedagogical field.

  7. Databases for highway inventories. Proposal for a new model

    Energy Technology Data Exchange (ETDEWEB)

    Perez Casan, J.A.

    2016-07-01

    Database models for highway inventories are based on classical schemes for relational databases: many related tables, in which the database designer establishes, a priori, every detail that they consider relevant for inventory management. This kind of database presents several problems. First, adapting the model and its applications when new database features appear is difficult. In addition, the different needs of different sets of road inventory users are difficult to fulfil with these schemes. For example, maintenance management services, road authorities and emergency services have different needs. In addition, this kind of database cannot be adapted to new scenarios, such as other countries and regions (that may classify roads or name certain elements differently). The problem is more complex if the language used in these scenarios is not the same as that used in the database design. In addition, technicians need a long time to learn to use the database efficiently. This paper proposes a flexible, multilanguage and multipurpose database model, which gives an effective and simple solution to the aforementioned problems. (Author)

  8. Corporate Social Responsibility And Islamic Business Organizations: A Proposed Model

    Directory of Open Access Journals (Sweden)

    Rusnah Muhamad

    2008-01-01

    Full Text Available The issue of corporate social responsibility (CSR has been of growing concern among business communities in recent years. Various corporate leaders maintain that business is considered to contribute fully to the society if it is effi cient, profi table and socially responsible. Islam is considered as addin (a way of life, thus, providing comprehensive guidelines in every aspects of the believers’ life. It is the aim of this paper to propose an Islamic model of corporate social responsibility based on human relationships with the God (hablun min’Allah; with other fellow human being (hablun min’an-nas and with the environment.Keywords : Corporate Social Responsibility, Islamic Business Organization

  9. Algorithms for boundary detection in radiographic images

    International Nuclear Information System (INIS)

    Gonzaga, Adilson; Franca, Celso Aparecido de

    1996-01-01

    Edge detecting techniques applied to radiographic digital images are discussed. Some algorithms have been implemented and the results are displayed to enhance boundary or hide details. An algorithm applied in a pre processed image with contrast enhanced is proposed and the results are discussed

  10. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  11. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  12. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  13. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  14. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  15. Methodology Using MELCOR Code to Model Proposed Hazard Scenario

    Energy Technology Data Exchange (ETDEWEB)

    Gavin Hawkley

    2010-07-01

    This study demonstrates a methodology for using the MELCOR code to model a proposed hazard scenario within a building containing radioactive powder, and the subsequent evaluation of a leak path factor (LPF) (or the amount of respirable material which that escapes a facility into the outside environment), implicit in the scenario. This LPF evaluation will analyzes the basis and applicability of an assumed standard multiplication of 0.5 × 0.5 (in which 0.5 represents the amount of material assumed to leave one area and enter another), for calculating an LPF value. The outside release is dependsent upon the ventilation/filtration system, both filtered and un-filtered, and from other pathways from the building, such as doorways (, both open and closed). This study is presents ed to show how the multiple leak path factorsLPFs from the interior building can be evaluated in a combinatory process in which a total leak path factorLPF is calculated, thus addressing the assumed multiplication, and allowing for the designation and assessment of a respirable source term (ST) for later consequence analysis, in which: the propagation of material released into the environmental atmosphere can be modeled and the dose received by a receptor placed downwind can be estimated and the distance adjusted to maintains such exposures as low as reasonably achievableALARA.. Also, this study will briefly addresses particle characteristics thatwhich affect atmospheric particle dispersion, and compares this dispersion with leak path factorLPF methodology.

  16. QAM: PROPOSED MODEL FOR QUALITY ASSURANCE IN CBSS

    Directory of Open Access Journals (Sweden)

    Latika Kharb

    2015-08-01

    Full Text Available Component-based software engineering (CBSE / Component-Based Development (CBD lays emphasis on decomposition of the engineered systems into functional or logical components with well-defined interfaces used for communication across the components. Component-based software development approach is based on the idea to develop software systems by selecting appropriate off-the-shelf components and then to assemble them with a well-defined software architecture. Because the new software development paradigm is much different from the traditional approach, quality assurance for component-based software development is a new topic in the software engineering research community. Because component-based software systems are developed on an underlying process different from that of the traditional software, their quality assurance model should address both the process of components and the process of the overall system. Quality assurance for component-based software systems during the life cycle is used to analyze the components for achievement of high quality component-based software systems. Although some Quality assurance techniques and component based approach to software engineering have been studied, there is still no clear and well-defined standard or guidelines for component-based software systems. Therefore, identification of the quality assurance characteristics, quality assurance models, quality assurance tools and quality assurance metrics, are under urgent need. As a major contribution in this paper, I have proposed QAM: Quality Assurance Model for component-based software development, which covers component requirement analysis, component development, component certification, component architecture design, integration, testing, and maintenance.

  17. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  18. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M.; Espinosa, Norman

    2013-01-01

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  19. A Proposed Model for Protein Crystal Nucleation and Growth

    Science.gov (United States)

    Pusey, Marc; Curreri, Peter A. (Technical Monitor)

    2002-01-01

    How does one take a molecule, strongly asymmetric in both shape and charge distribution, and assemble it into a crystal? We propose a model for the nucleation and crystal growth process for tetragonal lysozyme, based upon fluorescence, light, neutron, and X-ray scattering data, size exclusion chromatography experiments, dialysis kinetics, AFM, and modeling of growth rate data, from this and other laboratories. The first species formed is postulated to be a 'head to side' dimer. Through repeating associations involving the same intermolecular interactions this grows to a 4(sub 3) helix structure, that in turn serves as the basic unit for nucleation and subsequent crystal growth. High salt attenuates surface charges while promoting hydrophobic interactions. Symmetry facilitates subsequent helix-helix self-association. Assembly stability is enhanced when a four helix structure is obtained, with each bound to two neighbors. Only two unique interactions are required. The first are those for helix formation, where the dominant interaction is the intermolecular bridging anion. The second is the anti-parallel side-by-side helix-helix interaction, guided by alternating pairs of symmetry related salt bridges along each side. At this stage all eight unique positions of the P4(sub3)2(sub 1),2(sub 1) unit cell are filled. The process is one of a) attenuating the most strongly interacting groups, such that b) the molecules begin to self-associate in defined patterns, so that c) symmetry is obtained, which d) propagates as a growing crystal. Simple and conceptually obvious in hindsight, this tells much about what we are empirically doing when we crystallize macromolecules. By adjusting the growth parameters we are empirically balancing the intermolecular interactions, preferentially attenuating the dominant strong (for lysozyme the charged groups) while strengthening the lesser strong (hydrophobic) interactions. In the general case for proteins the lack of a singularly defined

  20. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  1. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  2. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  3. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  4. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  5. Neutronic characteristics of coupled moderator proposed in integrated model

    International Nuclear Information System (INIS)

    Teshigawara, Makoto; Meigo, Shin-ichiro; Sakata, Hideaki; Kai, Tetsuya; Harada, Masahide; Ikeda, Yujiro; Watanabe, Noboru

    2001-05-01

    A pulsed spallation source for the materials science and the life science is currently developing for its construction in the High Intensity Proton Accelerator Project proposed jointly by the Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK). This report presents the analytical results of the neutronic characteristics of the coupled moderator based on the analytical results obtained by using an integrated model which has established on the extensive neutronic and technical study. Total heat deposition in a hydrogen (H 2 ) moderator working as the main moderator was about 420 W/MW. Maximum nuclear heat density in the H 2 moderator was about 1 W/cm 3 /MW. Also total heat deposition in a premoderator was about 9.2 kW/MW. The heat density of the premoderator was comparable to that of the moderator vessel made of aluminum alloy. The heat density of the premoderator and the moderator vessel is about 1.2-2 times higher than that of the hydrogen moderator. The temperature from 300 K to 400 K of the premoderator did not affect on neutron intensity of the H 2 moderator. This suggested an engineering advantage on the thermal and hydraulic design. 6000 or 7000 type of a aluminum alloy was considered from the viewpoint of the neutron beam transmission. The proton beams scattered by the proton beam window did not affect on the nuclear heating in the H 2 moderator. The heat deposition in the H 2 moderator and the neutron intensity of the H 2 moderator did not depend on the proton beam profile but it did on the distance between the proton beam and the moderator. (author)

  6. A theoretical model predicting the intensity of emitted light per unit of x-ray exposure in radiographic screens

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukos, S; Kateris, A; Kalivas, N; Spyrou, G; Panayiotakis, G [Department of Medical Physics, School of Medicine, University of Patras, 265 00 pAtras (Greece); Kandarakis, I; Gavouras, D [Department of Medical Instrumentation Technology, Technological Educational Institution of Athens (Greece)

    1999-12-31

    A theoretical model predicting the intensity of light emitted by x-ray imaging phosphor screens per unit of area and time over incident x-ray flux (absolute efficiency) was developed. The model takes into account : A) the structure of the screens which consists of luminescent grains embedded in a binding matrix. B) the direct deposition of energy by x-ray absorption effects.. C) the re-absorption of K fluorescence characteristic x-rays produced when the x-ray energy exceeds the energy of the K absorption edge of the phosphor material. To test the model a set of (Gd,La)2O2S:Tb phosphor screens was prepared by sedimentation in the laboratory. Experimental absolute efficiency data were obtained at x-ray tube voltage range from 40 to 160 kVp. The coincidence between experimental and theoretical results were satisfactory. (authors) 7 refs., 4 figs.

  7. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  8. a Proposal for Generalization of 3d Models

    Science.gov (United States)

    Uyar, A.; Ulugtekin, N. N.

    2017-11-01

    In recent years, 3D models have been created of many cities around the world. Most of the 3D city models have been introduced as completely graphic or geometric models, and the semantic and topographic aspects of the models have been neglected. In order to use 3D city models beyond the task, a generalization is necessary. CityGML is an open data model and XML-based format for the storage and exchange of virtual 3D city models. Level of Details (LoD) which is an important concept for 3D modelling, can be defined as outlined degree or prior representation of real-world objects. The paper aim is first describes some requirements of 3D model generalization, then presents problems and approaches that have been developed in recent years. In conclude the paper will be a summary and outlook on problems and future work.

  9. Bayesian inference of chemical kinetic models from proposed reactions

    KAUST Repository

    Galagali, Nikhil; Marzouk, Youssef M.

    2015-01-01

    © 2014 Elsevier Ltd. Bayesian inference provides a natural framework for combining experimental data with prior knowledge to develop chemical kinetic models and quantify the associated uncertainties, not only in parameter values but also in model

  10. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  11. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  12. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  13. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  14. IMPROVING THE INTEROPERABILITY OF DISASTER MODELS: A CASE STUDY OF PROPOSING FIREML FOR FOREST FIRE MODEL

    Directory of Open Access Journals (Sweden)

    W. Jiang

    2018-04-01

    Full Text Available This paper presents a new standardized data format named Fire Markup Language (FireML, extended by the Geography Markup Language (GML of OGC, to elaborate upon the fire hazard model. The proposed FireML is able to standardize the input and output documents of a fire model for effectively communicating with different disaster management systems to ensure a good interoperability. To demonstrate the usage of FireML and testify its feasibility, an adopted forest fire spread model being compatible with FireML is described. And a 3DGIS disaster management system is developed to simulate the dynamic procedure of forest fire spread with the defined FireML documents. The proposed approach will enlighten ones who work on other disaster models' standardization work.

  15. Improving the Interoperability of Disaster Models: a Case Study of Proposing Fireml for Forest Fire Model

    Science.gov (United States)

    Jiang, W.; Wang, F.; Meng, Q.; Li, Z.; Liu, B.; Zheng, X.

    2018-04-01

    This paper presents a new standardized data format named Fire Markup Language (FireML), extended by the Geography Markup Language (GML) of OGC, to elaborate upon the fire hazard model. The proposed FireML is able to standardize the input and output documents of a fire model for effectively communicating with different disaster management systems to ensure a good interoperability. To demonstrate the usage of FireML and testify its feasibility, an adopted forest fire spread model being compatible with FireML is described. And a 3DGIS disaster management system is developed to simulate the dynamic procedure of forest fire spread with the defined FireML documents. The proposed approach will enlighten ones who work on other disaster models' standardization work.

  16. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  17. Detecting objects in radiographs for homeland security

    Science.gov (United States)

    Prasad, Lakshman; Snyder, Hans

    2005-05-01

    We present a general scheme for segmenting a radiographic image into polygons that correspond to visual features. This decomposition provides a vectorized representation that is a high-level description of the image. The polygons correspond to objects or object parts present in the image. This characterization of radiographs allows the direct application of several shape recognition algorithms to identify objects. In this paper we describe the use of constrained Delaunay triangulations as a uniform foundational tool to achieve multiple visual tasks, namely image segmentation, shape decomposition, and parts-based shape matching. Shape decomposition yields parts that serve as tokens representing local shape characteristics. Parts-based shape matching enables the recognition of objects in the presence of occlusions, which commonly occur in radiographs. The polygonal representation of image features affords the efficient design and application of sophisticated geometric filtering methods to detect large-scale structural properties of objects in images. Finally, the representation of radiographs via polygons results in significant reduction of image file sizes and permits the scalable graphical representation of images, along with annotations of detected objects, in the SVG (scalable vector graphics) format that is proposed by the world wide web consortium (W3C). This is a textual representation that can be compressed and encrypted for efficient and secure transmission of information over wireless channels and on the Internet. In particular, our methods described here provide an algorithmic framework for developing image analysis tools for screening cargo at ports of entry for homeland security.

  18. Proposing a Capability Perspective on Digital Business Models

    OpenAIRE

    Bärenfänger, Rieke; Otto, Boris

    2015-01-01

    Business models comprehensively describe the functioning of businesses in contemporary economic, technological, and societal environments. This paper focuses on the characteristics of digital business models from the perspective of capability research and develops a capability model for digital businesses. Following the design science research (DSR) methodology, multiple evaluation and design iterations were performed. Contributions to the design process came from IS/IT practice and the resea...

  19. A proposed model for paradigmatic relations within an emergent discipline

    Directory of Open Access Journals (Sweden)

    Jack D. Glazier

    2002-01-01

    Full Text Available This article is the vehicle for purposing a model for mapping the processual change associated with disciplinary and paradigmatic development. Change of this sort is contingent on the degree of consistency achieved within theory groups. Consistency, in this case, is equated theory and paradigm dominance. The symbolic interactionist tradition supplies the assumptions on which the model is grounded. Examination of the model is accomplished by contrasting it with Thomas Kuhn’s theory. The recent history of library and information science education in the U.S. serves as context and exemplar for application of the model

  20. Proposing an Environmental Excellence Self-Assessment Model

    DEFF Research Database (Denmark)

    Meulengracht Jensen, Peter; Johansen, John; Wæhrens, Brian Vejrum

    2013-01-01

    that the EEA model can be used in global organizations to differentiate environmental efforts depending on the maturity stage of the individual sites. Furthermore, the model can be used to support the decision-making process regarding when organizations should embark on more complex environmental efforts......This paper presents an Environmental Excellence Self-Assessment (EEA) model based on the structure of the European Foundation of Quality Management Business Excellence Framework. Four theoretical scenarios for deploying the model are presented as well as managerial implications, suggesting...

  1. An improved method for simulating radiographs

    International Nuclear Information System (INIS)

    Laguna, G.W.

    1986-01-01

    The parameters involved in generating actual radiographs and what can and cannot be modeled are examined in this report. Using the spectral distribution of the radiation source and the mass absorption curve for the material comprising the part to be modeled, the actual amount of radiation that would pass through the part and reach the film is determined. This method increases confidence in the results of the simulation and enables the modeling of parts made of multiple materials

  2. Proposal of a probabilistic dose-response model

    International Nuclear Information System (INIS)

    Barrachina, M.

    1997-01-01

    A biologically updated dose-response model is presented as an alternative to the linear-quadratic model currently in use for cancer risk assessment. The new model is based on the probability functions for misrepair and/or unrepair of DNA lesions, in terms of the radiation damage production rate in the cell (supposedly, a stem cell) and its repair-rate constant. The model makes use, interpreting it on the basis of misrepair probabilities, of the ''dose and dose-rate effectiveness factor'' of ICRP, and provides the way for a continuous extrapolation between the high and low dose-rate regions, ratifying the ''linear non-threshold hypothesis'' as the main option. Anyhow, the model throws some doubts about the additive property of the dose. (author)

  3. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  4. Femoral and tibial torsion measurements in children and adolescents: comparison of MRI and 3D models based on low-dose biplanar radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Rosskopf, Andrea B.; Buck, Florian M.; Pfirrmann, Christian W.A. [University Hospital Balgrist, Radiology, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland); Ramseier, Leonhard E. [University of Zurich, Faculty of Medicine, Zurich (Switzerland); University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland)

    2017-04-15

    The aim of our study was to evaluate the reliability and interchangeability of femoral (FT) and tibial torsion (TT) measurements in children using magnetic resonance (MR) imaging compared to measurements on 3D models based on biplanar radiographs (BPR). FT and TT were measured in 60 children (mean age 10.1 years; range 6.2-16.2 years; 28 female) using axial MR images by two readers. MR measurements were compared to measurements based on BPR-3D models by two separate independent readers. Interreader and intermethod agreements were calculated using descriptive statistics, the intraclass correlation coefficient (ICC), and Bland-Altman analysis. FT/TT was -8.4 -54.1 /0 -45.9 on MR images and -13 -63 /4 -52 for measurements on BPR-3D models. The median of difference between the two methods was -0.18 (range -13.6 -19.1 ) for FT and -0.20 (range -18.4 -9.5 ) for TT, respectively. Interreader agreement (ICC) of FT/TT measurements was 0.98/0.96 on MR images and 0.98/0.94 on BPR 3D models. Intermethod agreement (ICC) for MR measurements was 0.95 [95% confidence interval (CI), 0.93-0.96] for FT and of 0.86 (CI, 0.24-0.95) for TT. Mean interreader differences at MR were 3.1 (0.0 -8.0 ) for FT and 3.2 (0.1 -9.5 ) for TT. On Bland-Altman plots all measurements were within the 95% limit of agreement (-10.8 ; 11.5 for FT; -14.6 ; 4.2 ) for TT - except for five measurements of FT and six measurements of TT. FT measurements on MR images are comparable to measurements using BPR-3D models. TT measurements differ between the two modalities, but the discrepancy is comparable to measurement variations between CT and BPR. (orig.)

  5. A Proposed Conceptual Model to Measure Unwarranted Practice Variation

    National Research Council Canada - National Science Library

    Barr, Andrew M

    2007-01-01

    .... Employing a unit of analysis of the U.S. Army healthcare system and utilizing research by Wennberg and the Institute of Medicine, a model describing healthcare quality in terms of unwarranted practice variation and healthcare outcomes...

  6. comparative analysis of some existing kinetic models with proposed

    African Journals Online (AJOL)

    IGNATIUS NWIDI

    two statistical parameters namely; linear regression coefficient of correlation (R2) and ... Keynotes: Heavy metals, Biosorption, Kinetics Models, Comparative analysis, Average Relative Error. 1. ... If the flow rate is low, a simple manual batch.

  7. Proposal for a new CAPE-OPEN Object Model

    Science.gov (United States)

    Process simulation applications require the exchange of significant amounts of data between the flowsheet environment, unit operation model, and thermodynamic server. Packing and unpacking various data types and exchanging data using structured text-based architectures, including...

  8. 2012 Community Earth System Model (CESM) Tutorial - Proposal to DOE

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Marika [National Center for Atmospheric Research, Boulder, CO (United States); Bailey, David A [National Center for Atmospheric Research, Boulder, CO (United States)

    2013-03-18

    The Community Earth System Model (CESM) is a fully-coupled, global climate model that provides state-of-the-art computer simulations of the Earth's past, present, and future climate states. This document provides the agenda and list of participants for the conference. Web materials for all lectures and practical sessions available from: http://www.cesm.ucar.edu/events/tutorials/073012/ .

  9. Product/Service-Systems: Proposal for models and terminology

    DEFF Research Database (Denmark)

    Matzen, Detlef; Tan, Adrian; Andreasen, Mogens Myrup

    2005-01-01

    very blurred and ill defined. This paper will try to identify the fundamental characteristics of PSS and propose a system of concepts that can be used to describe and discuss the phenomenon, for the purpose of developing new PSS solutions. Coming from a tradition of product development research......Over recent years a growing number of studies and research programmes have been conducted on the issue of product/service-systems (PSS) [1, 2] and results have been presented at this row of symposia [3, 4]. These studies usually analyse the potential of integrated solutions to reduce...... the environmental impacts of human consumption activity or optimise a company’s ability to cope with the influences arising from the emerging globalisation of economic and business activities. Since there has not been worked on a coherent terminology for the terms and concepts used in PSS research, the area remains...

  10. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  11. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  12. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  13. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  14. Psychological debriefing (PD of trauma: a proposed model for Africa

    Directory of Open Access Journals (Sweden)

    E L Van Dyk

    2010-03-01

    Full Text Available Africa is a continent with severe trauma. Traumatic events include experiences of child soldiers, people living in war and conflict zones, and people struggling with the HIV/AIDS pandemic. These events cause high levels of trauma. The trauma causes psychological disorders like post traumatic stress disorder, acute stress disorder and combat stress reaction, specific in the military environment. This article focuses on a better understanding of the implications of trauma for military people and civilians. It discusses the different theories and models of psychological debriefing. Lastly the article discusses psychological debriefing models for military forces and the civil ian population to prevent severe psychopathology after traumatic incidents in Africa.

  15. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  16. Queering Constructs: Proposing a Dynamic Gender and Sexuality Model

    Science.gov (United States)

    Jourian, T. J.

    2015-01-01

    Higher education educators commonly understand social identities, including gender, to be fluid and dynamic. Lev's (2004) model of four components of sexual identity is commonly used to demonstrate the fluidity of sex, gender, and sexuality for individuals, but it does little to address the fixedness of those constructs. Through a multipronged…

  17. Proposing a Metaliteracy Model to Redefine Information Literacy

    Science.gov (United States)

    Jacobson, Trudi E.; Mackey, Thomas P.

    2013-01-01

    Metaliteracy is envisioned as a comprehensive model for information literacy to advance critical thinking and reflection in social media, open learning settings, and online communities. At this critical time in higher education, an expansion of the original definition of information literacy is required to include the interactive production and…

  18. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  19. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  20. Proposing a Formalised Model for Mindful Information Systems Offshoring

    Science.gov (United States)

    Costello, Gabriel J.; Coughlan, Chris; Donnellan, Brian; Gadatsch, Andreas

    The central thesis of this chapter is that mathematical economics can provide a novel approach to the examination of offshoring business decisions and provide an impetus for future research in the area. A growing body of research indicates that projected cost savings from IT offshoring projects are not being met. Furthermore, evidence suggests that decision-making processes have been more emotional than rational, and that many offshoring arrangements have been rushed into without adequate analysis of the true costs involved. Building on the concept of mindfulness and mindlessness introduced to the IS literature by Swanson and Ramiller, a cost equation is developed using “deductive reasoning rather than inductive study” in the tradition of mathematical economics. The model endeavours to capture a wide range of both the quantitative and qualitative parameters. Although the economic model is illustrated against the background of a European scenario, the theoretical framework is generic and applicable to organisations in any global location.

  1. Proposal for a telehealth concept in the translational research model.

    Science.gov (United States)

    Silva, Angélica Baptista; Morel, Carlos Médicis; Moraes, Ilara Hämmerli Sozzi de

    2014-04-01

    To review the conceptual relationship between telehealth and translational research. Bibliographical search on telehealth was conducted in the Scopus, Cochrane BVS, LILACS and MEDLINE databases to find experiences of telehealth in conjunction with discussion of translational research in health. The search retrieved eight studies based on analysis of models of the five stages of translational research and the multiple strands of public health policy in the context of telehealth in Brazil. The models were applied to telehealth activities concerning the Network of Human Milk Banks, in the Telemedicine University Network. The translational research cycle of human milk collected, stored and distributed presents several integrated telehealth initiatives, such as video conferencing, and software and portals for synthesizing knowledge, composing elements of an information ecosystem, mediated by information and communication technologies in the health system. Telehealth should be composed of a set of activities in a computer mediated network promoting the translation of knowledge between research and health services.

  2. Convective effects in a regulatory and proposed fire model

    International Nuclear Information System (INIS)

    Wix, S.D.; Hohnstreiter, G.F.

    1995-01-01

    Radiation is the dominant mode of heat transfer in large fires. However, convection can be as much as 10 to 20 percent of the total heat transfer to an object in a large fire. The current radioactive material transportation packaging regulations include convection as a mode of heat transfer in the accident condition scenario. The current International Atomic Energy Agency Safety Series 6 packaging regulation states ''the convection coefficient shall be that value which the designer can justify if the package were exposed to the specified fire''. The current Title 10, Code of Federal Regulations, Part 71 (10CFR71) packaging regulation states ''when significant, convection heat input must be included on the basis of still, ambient air at 800 degrees C (1475 degrees F)''. Two questions that can arise in an analysts mind from an examination of the packaging regulations is whether convection is significant and whether convection should be included in the design analysis of a radioactive materials transportation container. The objective of this study is to examine the convective effects on an actual radioactive materials transportation package using a regulatory and a proposed thermal boundary condition

  3. Proposal of a model of mammalian neural induction

    Science.gov (United States)

    Levine, Ariel J.; Brivanlou, Ali H.

    2009-01-01

    How does the vertebrate embryo make a nervous system? This complex question has been at the center of developmental biology for many years. The earliest step in this process – the induction of neural tissue – is intimately linked to patterning of the entire early embryo, and the molecular and embryological basis these processes are beginning to emerge. Here, we analyze classic and cutting-edge findings on neural induction in the mouse. We find that data from genetics, tissue explants, tissue grafting, and molecular marker expression support a coherent framework for mammalian neural induction. In this model, the gastrula organizer of the mouse embryo inhibits BMP signaling to allow neural tissue to form as a default fate – in the absence of instructive signals. The first neural tissue induced is anterior and subsequent neural tissue is posteriorized to form the midbrain, hindbrain, and spinal cord. The anterior visceral endoderm protects the pre-specified anterior neural fate from similar posteriorization, allowing formation of forebrain. This model is very similar to the default model of neural induction in the frog, thus bridging the evolutionary gap between amphibians and mammals. PMID:17585896

  4. An Applied Image Processing for Radiographic Testing

    International Nuclear Information System (INIS)

    Ratchason, Surasak; Tuammee, Sopida; Srisroal Anusara

    2005-10-01

    An applied image processing for radiographic testing (RT) is desirable because it decreases time-consuming, decreases the cost of inspection process that need the experienced workers, and improves the inspection quality. This paper presents the primary study of image processing for RT-films that is the welding-film. The proposed approach to determine the defects on weld-images. The BMP image-files are opened and developed by computer program that using Borland C ++ . The software has five main methods that are Histogram, Contrast Enhancement, Edge Detection, Image Segmentation and Image Restoration. Each the main method has the several sub method that are the selected options. The results showed that the effective software can detect defects and the varied method suit for the different radiographic images. Furthermore, improving images are better when two methods are incorporated

  5. A proposal of a renormalizable Nambu-Jona-Lasinio model

    Science.gov (United States)

    Cabo Montes de Oca, Alejandro

    2018-03-01

    A local and gauge invariant gauge field model including Nambu-Jona-Lasinio (NJL) and QCD Lagrangian terms in its action is introduced. Surprisingly, it becomes power counting renormalizable. This occurs thanks to the presence of action terms which modify the quark propagators, to become more decreasing that the Dirac one at large momenta in a Lee-Wick form, implying power counting renormalizability. The appearance of finite quark masses already in the tree approximation in the scheme is determined by the fact that the new action terms explicitly break chiral invariance. In this starting work we present the renormalized Feynman diagram expansion of the model and derive the formula for the degree of divergence of the diagrams. An explanation for the usual exclusion of the added Lagrangian terms is presented. In addition, the primitíve divergent graphs are identified. We start their evaluation by calculating the simpler contribution to the gluon polarization operator. The divergent and finite parts both result transverse as required by gauge invariance. The full evaluation of the various primitive divergences, which are required for completely defining the counterterm Feynman expansion will be considered in coming works, for further allowing to discuss the flavour symmetry breaking and unitarity.

  6. A proposed model of e-trust for electronic banking

    Directory of Open Access Journals (Sweden)

    Neda Yousefi

    2015-11-01

    Full Text Available Customer’s trust is the most important and one of the key factors of success in e-commerce. However, trust is the essential aspects of e-banking adoption and the main element for building long-term relationships with the bank's customers. So the purpose of this research is to investigate the factors influencing on customer′s trust in e-banking services and prioritize them. Therefore, designed questionnaire was distributed among 177 electronic service customers in number of banks in the city of Karaj, Iran. Likert quintuplet scales were used to measure the variables. After collecting the questionnaires, the data were analyzed by structural equation modeling (by using LISREL 8.5. The results revealed that quality of electronic services such as ease of use, privacy and security, individual characteristics of customers such as disposition to trust and features of bank such as reputation, size and dependence on government, have had the greatest effect on customer′s trust in e-banking services.

  7. A high-accuracy image registration algorithm using phase-only correlation for dental radiographs

    International Nuclear Information System (INIS)

    Ito, Koichi; Nikaido, Akira; Aoki, Takafumi; Kosuge, Eiko; Kawamata, Ryota; Kashima, Isamu

    2008-01-01

    Dental radiographs have been used for the accurate assessment and treatment of dental diseases. The nonlinear deformation between two dental radiographs may be observed, even if they are taken from the same oral regions of the subject. For an accurate diagnosis, the complete geometric registration between radiographs is required. This paper presents an efficient dental radiograph registration algorithm using Phase-Only Correlation (POC) function. The use of phase components in 2D (two-dimensional) discrete Fourier transforms of dental radiograph images makes possible to achieve highly robust image registration and recognition. Experimental evaluation using a dental radiograph database indicates that the proposed algorithm exhibits efficient recognition performance even for distorted radiographs. (author)

  8. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  9. Radiographic visualization of magma dynamics in an erupting volcano.

    Science.gov (United States)

    Tanaka, Hiroyuki K M; Kusagaya, Taro; Shinohara, Hiroshi

    2014-03-10

    Radiographic imaging of magma dynamics in a volcanic conduit provides detailed information about ascent and descent of magma, the magma flow rate, the conduit diameter and inflation and deflation of magma due to volatile expansion and release. Here we report the first radiographic observation of the ascent and descent of magma along a conduit utilizing atmospheric (cosmic ray) muons (muography) with dynamic radiographic imaging. Time sequential radiographic images show that the top of the magma column ascends right beneath the crater floor through which the eruption column was observed. In addition to the visualization of this magma inflation, we report a sequence of images that show magma descending. We further propose that the monitoring of temporal variations in the gas volume fraction of magma as well as its position in a conduit can be used to support existing eruption prediction procedures.

  10. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  11. A proposed wind shift model for the German reactor safety study

    International Nuclear Information System (INIS)

    Aldrich, D.C.; Bayer, A.; Schueckler, M.

    1979-04-01

    To account for hourly wind direction changes, a wind shift model has been proposed. Using hourly recorded wind speed and direction data, the model modifies the angular distribution of radionuclide concentrations calculated by a straightline model, and is intended to better represent the concentrations in areas close to the reactor where potential doses might exceed the threshold level for early fatalities. 115 weather sequences were used, both with and without the proposed wind shift model, to calculate probability distributions for early fatalities. The use of the proposed model results in a reduction of the mean and peak values of that distribution by 36% and 29%, respectively. (orig./HP) [de

  12. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  13. Measuring anteversion in the femoral neck from routine radiographs

    International Nuclear Information System (INIS)

    Hermann, K.L.; Egund, N.

    1998-01-01

    Purpose: To describe a new method for measuring femoral neck anteversion (FNA) that requires only one lateral radiograph of the knee in addition to routine radiographs of the hip for evaluation of total hip replacement; and to compare the proposed method with FNA measurement by means of 3D CT. Material and Methods: In 18 femoral specimens, radiographic examinations of the hip and knee, in three different rotational positions, and one CT examination were made, and the measurements of FNA were compared. Similarly, in 38 patients with 40 total hip replacements, measurements form routine radiographic examinations of the hip and knee and from CT examinations were compared. The accuracy and reproducibility of the FNA measurements produced by this proposed method were calculated. Results: Accuracy and reproducibility were 2 and 2 for the proposed method in the femoral specimen study, and accuracy was 4 in the hip patient study. The proposed method had a minor flaw that was caused almost solely by differences in knee size at inward rotation of the femur. Conclusion: FNA measurement can be made from a routine radiographic examination of the hip and a lateral view of the knee. This method achieves an acceptable level of accuracy and reproducibility. (orig.)

  14. Proposal for operator's mental model using the concept of multilevel flow modeling

    International Nuclear Information System (INIS)

    Yoshimura, Seiichi; Takano, Kenichi; Sasou, Kunihide

    1995-01-01

    It is necessary to analyze an operator's thinking process and a operator team's intension forming process for preventing human errors in a highly advanced huge system like a nuclear power plant. Central Research Institute of Electric Power Industry is promoting a research project to establish human error prevention countermeasures by modeling the thinking and intension forming process. The important is the future prediction and the cause identification when abnormal situations occur in a nuclear power plant. The concept of Multilevel Flow Modeling (MFM) seems to be effective as an operator's mental model which performs the future prediction and the cause identification. MFM is a concept which qualitatively describes the plant functions by energy and mass flows and also describes the plant status by breaking down the targets in a hierarchical manner which a plant should achieve. In this paper, an operator's mental model using the concept of MFM was proposed and a nuclear power plant diagnosis support system using MFM was developed. The system evaluation test by personnel who have operational experience in nuclear power plants revealed that MFM was superior in the future prediction and the cause identification to a traditional nuclear power plant status display system which used mimics and trends. MFM proved to be useful as an operator's mental model by the test. (author)

  15. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  16. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  17. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  18. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  19. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  20. Effects of radiographic contrast media on the serum complement system

    International Nuclear Information System (INIS)

    Tirone, P.; Boldrini, E.

    1983-01-01

    The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the use of nonionic contrast for radiological procedures necessitating the introduction of contrast material into the blood compartment would imply a reduced risk of anaphylactoid reactions. (orig.)

  1. The radiographic features of familial expansile osteolysis

    International Nuclear Information System (INIS)

    Crone, M.D.; Wallace, R.G.H.

    1990-01-01

    The radiographic features of a unique autosomal dominant bone dysplasia are presented. The features are classified as generalised and/or focal. Generalised features are either altered trabecular pattern or modelling abnormalities. Focal features comprise lytic areas which progressively enlarge, producing expansion of the bone and eventual disintegration due to fibrous and finally fatty replacement of the normal medulla. Almost 90% of these lesions occur in the appendicular skeleton. Clinically, hearing loss is the earliest manifestation of the disease, presenting sometimes as early as 4 years of age. Apical and cervical resorption of teeth is extremely common, resulting in premature loss of teeth. Radiologically, the differential diagnosis refers to Paget's disease, polyostotic fibrous dysplasia, and osteofibrous dysplasia. The progressive destruction of the bone is similar to massive osteolysis (Gorham's disease). The radiographic features in combination with the histopathology render the condition unique. (orig.)

  2. Development of a external exposure computational model for studying of input dose in skin for radiographs of thorax and vertebral column

    International Nuclear Information System (INIS)

    Muniz, Bianca C.; Menezes, Claudio J.M.; Vieira, Jose W.

    2014-01-01

    The dosimetric measurements do not always happen directly in the human body. Therefore, these assessments can be performed using anthropomorphic models (phantoms) evidencing models computational exposure (MCE) using techniques of Monte Carlo Method for virtual simulations. These processing techniques coupled with more powerful and affordable computers make the Monte Carlo method one of the tools most used worldwide in radiation transport area. In this work, the Monte Carlo EGS4 program was used to develop a computer model of external exposure to study the entrance skin dose for chest and column X-radiography and, aiming to optimize these practices by reducing doses to patients, professionals involved and the general public. The results obtained experimentally with the electrometer Radcal, model 9015, associated with the ionization chamber for radiology model 10X5-6, showed that the proposed computational model can be used in quality assurance programs in radiodiagnostic, evaluating the entrance skin dose when varying parameters of the radiation beam such as kilo voltage peak (kVp), current-time product (mAs), total filtration and distance surface source (DFS), optimizing the practices in radiodiagnostic and meeting the current regulation

  3. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  4. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  5. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  6. A New Proposed Cost Model for List Accessing Problem using Buffering

    OpenAIRE

    Mohanty, Rakesh; Bhoi, Seetaya; Tripathy, Sasmita

    2011-01-01

    There are many existing well known cost models for the list accessing problem. The standard cost model developed by Sleator and Tarjan is most widely used. In this paper, we have made a comprehensive study of the existing cost models and proposed a new cost model for the list accessing problem. In our proposed cost model, for calculating the processing cost of request sequence using a singly linked list, we consider the access cost, matching cost and replacement cost. The cost of processing a...

  7. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  8. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  9. PROPOSED SUITE OF MODELS FOR ESTIMATING DOSE RESULTING FROM EXPOSURES BY THE DERMAL ROUTE

    Science.gov (United States)

    Recent risk assessment guidance emphasizes consideration of mechanistic factors for influencing disposition of a toxicant. To incorporate mechanistic information into risk assessment, a suite of models is proposed for use in characterizing and quantifying dosimetry of toxic age...

  10. An Analytical Analysis of Hydraulic Jump in Triangular Channel: A Proposed Model

    Science.gov (United States)

    Khan, S. A.

    2013-05-01

    The paper presents the theoretical study of hydraulic jump in triangular channel section. Presuming the jump as one dimensional free shear layer with hydrostatic pressure distribution across it and using momentum equation, specific force equation is obtained. Using the specific force equation and eddy viscosity equation, analytical models for sequent depth, dimensionless profile, turbulent shear stress distribution and energy loss for various initial Froude numbers have been obtained. The proposed models for sequent depth and energy loss are also compared with the other developed models. The proposed energy loss model also provides the energy loss at any point along the jump, while this provision is not available in the models of other investigators. Newton-Raphson and Runge-Kutta methods are used for the solution of the proposed model. The outcome of this study can be used in the design of stilling basin floor and side walls on permeable foundations.

  11. Relation between size of contrast meter and radiographic density difference for radiographic test aluminium welds

    International Nuclear Information System (INIS)

    Senda, Tomio; Hirayama, Kazuo; Masaoka, Naotoshi; Fujita, Minoru.

    1977-01-01

    The influence of contrast meter with difference surface area (5.0 mm x 5.0 mm, 10.0 mm x 10.0 mm, 15.0 mm x 15.0 mm, 30.0 mm x 30.0 mm) and separated type on radiographic density difference (Δ D) were investigated for radiographic test of aluminum welds. It was found that the effect of scattered radiation on contrast meter represented highest at test specimen thickness of 20 mm, and Δ D was constant as the size was increased from 10.0 mm x 10.0 mm to 15.0 mm x 15.0 mm for aluminum contrast meter. For this reason, a proposal of the contrast meter with 10.0 mm x 10.0 mm (surface area) has made to replace (15.0 mm x 15 mm) at amendment of JIS Z 3105. (auth.)

  12. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  13. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  14. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  15. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  16. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  17. Automatic joint alignment measurements from pre- and post-operative long leg standing radiographs

    NARCIS (Netherlands)

    Goossen, A.; Weber, G.M.; Dries, S.P.M.

    2012-01-01

    Objectives: For diagnosis or treatment assessment of knee joint osteoarthritis it is required to measure bone morphometry from radiographic images. We propose a method for automatic measurement of joint alignment from pre-operative as well as post-operative radiographs.Methods: In a two step

  18. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  19. 78 FR 38091 - Airworthiness Criteria: Proposed Airship Design Criteria for Lockheed Martin Aeronautics Model...

    Science.gov (United States)

    2013-06-25

    ..., 2012 Lockheed Martin Aeronautics submitted an application for type certification for the model LMZ1M..., views, or arguments as they may desire. Commenters should identify the proposed design criteria on the... Lockheed Martin Aeronautics submitted an application for type certification for the model LMZ1M airship...

  20. Proposed Model of Information Behaviour in Crisis: The Case of Hurricane Sandy

    Science.gov (United States)

    Lopatovska, Irene; Smiley, Bobby

    2013-01-01

    Introduction: The paper proposes a model of information behaviour in crisis. No previous model has attempted to integrate information resources, information behaviour and needs of the storm-affected communities within the temporal stages of a natural disaster. Method: The study was designed as autoethnography. The data were collected through a…

  1. Non-monotonic reasoning in conceptual modeling and ontology design: A proposal

    CSIR Research Space (South Africa)

    Casini, G

    2013-06-01

    Full Text Available -1 2nd International Workshop on Ontologies and Conceptual Modeling (Onto.Com 2013), Valencia, Spain, 17-21 June 2013 Non-monotonic reasoning in conceptual modeling and ontology design: A proposal Giovanni Casini1 and Alessandro Mosca2 1...

  2. The Proposed Model of Collaborative Virtual Learning Environment for Introductory Programming Course

    Science.gov (United States)

    Othman, Mahfudzah; Othman, Muhaini

    2012-01-01

    This paper discusses the proposed model of the collaborative virtual learning system for the introductory computer programming course which uses one of the collaborative learning techniques known as the "Think-Pair-Share". The main objective of this study is to design a model for an online learning system that facilitates the…

  3. Standardized radiographic interpretation of thoracic tuberculosis in children

    International Nuclear Information System (INIS)

    Concepcion, Nathan David P.; Laya, Bernard F.; Andronikou, Savvas; Daltro, Pedro A.N.; Sanchez, Marion O.; Uy, Jacqueline Austine U.; Lim, Timothy Reynold U.

    2017-01-01

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging. (orig.)

  4. Standardized radiographic interpretation of thoracic tuberculosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Concepcion, Nathan David P.; Laya, Bernard F. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Taguig City (Philippines); St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Quezon City (Philippines); Andronikou, Savvas [Bristol Royal Hospital for Children and the University of Bristol, Department of Paediatric Radiology, Bristol (United Kingdom); Daltro, Pedro A.N. [Clinica de Diagnostico por Imagem, Section of Pediatric Radiology, Rio de Janeiro (Brazil); Sanchez, Marion O. [St. Luke' s Medical Center, Section of Pediatric Pulmonology, Institute of Pulmonary Medicine, Quezon City (Philippines); Uy, Jacqueline Austine U. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Taguig City (Philippines); Lim, Timothy Reynold U. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Quezon City (Philippines)

    2017-09-15

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging. (orig.)

  5. Standardized radiographic interpretation of thoracic tuberculosis in children.

    Science.gov (United States)

    Concepcion, Nathan David P; Laya, Bernard F; Andronikou, Savvas; Daltro, Pedro A N; Sanchez, Marion O; Uy, Jacqueline Austine U; Lim, Timothy Reynold U

    2017-09-01

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging.

  6. General-purpose radiographic and fluoroscopic table

    International Nuclear Information System (INIS)

    Ishizaki, Noritaka

    1982-01-01

    A new series of diagnostic tables, Model DT-KEL, was developed for general-purpose radiographic and fluoroscopic systems. Through several investigations, the table was so constructed that the basic techniques be general radiography and GI examination, and other techniques be optionally added. The diagnostic tables involve the full series of the type for various purposes and are systematized with the surrounding equipment. A retractable mechanism of grids was adopted first for general use. The fine grids with a density of 57 lines per cm, which was adopted in KEL-2, reduced the X-ray doses by 16 percent. (author)

  7. BLAM (Benthic Light Availability Model): A Proposed Model of Hydrogeomorphic Controls on Light in Rivers

    Science.gov (United States)

    Julian, J. P.; Doyle, M. W.; Stanley, E. H.

    2006-12-01

    Light is vital to the dynamics of aquatic ecosystems. It drives photosynthesis and photochemical reactions, affects thermal structure, and influences behavior of aquatic biota. Despite the fundamental role of light to riverine ecosystems, light studies in rivers have been mostly neglected because i) boundary conditions (e.g., banks, riparian vegetation) make ambient light measurements difficult, and ii) the optical water quality of rivers is highly variable and difficult to characterize. We propose a benthic light availability model (BLAM) that predicts the percent of incoming photosynthetically active radiation (PAR) available at the river bed. BLAM was developed by quantifying light attenuation of the five hydrogeomorphic controls that dictate riverine light availability: topography, riparian vegetation, channel geometry, optical water quality, and water depth. BLAM was calibrated using hydrogeomorphic data and light measurements from two rivers: Deep River - a 5th-order, turbid river in central North Carolina, and Big Spring Creek - a 2nd-order, optically clear stream in central Wisconsin. We used a series of four PAR sensors to measure i) above-canopy PAR, ii) PAR above water surface, iii) PAR below water surface, and iv) PAR on stream bed. These measurements were used to develop empirical light attenuation coefficients, which were then used in combination with optical water quality measurements, shading analyses, channel surveys, and flow records to quantify the spatial and temporal variability in riverine light availability. Finally, we apply BLAM to the Baraboo River - a 6th-order, 120-mile, unimpounded river in central Wisconsin - in order to characterize light availability along the river continuum (from headwaters to mouth).

  8. Quantitative radiographic analysis of fiber reinforced polymer composites.

    Science.gov (United States)

    Baidya, K P; Ramakrishna, S; Rahman, M; Ritchie, A

    2001-01-01

    X-ray radiographic examination of the bone fracture healing process is a widely used method in the treatment and management of patients. Medical devices made of metallic alloys reportedly produce considerable artifacts that make the interpretation of radiographs difficult. Fiber reinforced polymer composite materials have been proposed to replace metallic alloys in certain medical devices because of their radiolucency, light weight, and tailorable mechanical properties. The primary objective of this paper is to provide a comparable radiographic analysis of different fiber reinforced polymer composites that are considered suitable for biomedical applications. Composite materials investigated consist of glass, aramid (Kevlar-29), and carbon reinforcement fibers, and epoxy and polyether-ether-ketone (PEEK) matrices. The total mass attenuation coefficient of each material was measured using clinical X-rays (50 kev). The carbon fiber reinforced composites were found to be more radiolucent than the glass and kevlar fiber reinforced composites.

  9. A Framework Proposal For Choosing A New Business Implementation Model In Henkel

    OpenAIRE

    Li, Tsz Wan

    2015-01-01

    Henkel's New Business team is a corporate venturing unit that explores corporate entrepreneurial activities on behalf of Henkel Adhesives Technologies. The new business ideas are implemented through one of these models: incubator, venturing or innovation ecosystem. In current practice, there is no systematic framework in place to choose the implementation model. The goal of the thesis is to propose a framework for choosing the most appropriate model for implementation of a new business idea i...

  10. Vertebral physitis: a radiographic diagnosis to be separated from discospondylitis: a preliminary report

    International Nuclear Information System (INIS)

    Jimenez, M.M.; O'Callaghan, M.W.

    1995-01-01

    A retrospective study was initiated to investigate the incidence, radiographic appearance and progression of vertebral physitis, a condition the authors propose as a separate radiographic diagnosis from discospondylitis. From 30 dogs with an initial radiographic diagnosis of discospondylitis, six dogs (five less than two years old) had radiographic signs believed to represent vertebral physitis. Bone lysis initially confined to the caudal physeal zone of affected vertebrae and sparing the vertebral endplates characterized the vertebral physitis lesions. Subsequent collapse of the caudoventral vertebral body and reactive spondylosis arising only from the caudal vertebral margins followed as the lesions progressed. By contrast, discospondylitis lesions originated as symmetric lysis of the vertebral endplates with reactive sclerosis in both vertebral bodies, and subsequent symmetric spondylosis. As a result of the differing radiographic patterns demonstrated by the physitis and discospondylitis lesions the author's also propose an alternative pathogenesis from that which is generally accepted for discospondylitis

  11. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  12. Two-Dimensional Model Test Study of New Western Breakwater Proposal for Port of Hanstholm

    DEFF Research Database (Denmark)

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2016 with the proposed trunk section for the new western breakwater in Port of Hanstholm. The objectives of the model tests were to study the stability of the armour layer, toe...... erosion, overtopping and transmission. The scale used for the model tests was 1:61.5. Unless otherwise specified all values given in this report are prototype values converted from the model to prototype according to the Froude model law....

  13. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  14. The Motivational Knowledge Management Model: proposal to apply it in the library sector

    Directory of Open Access Journals (Sweden)

    Daniel López-Fernández

    2016-12-01

    Full Text Available In professional environments, attention paid to aspects such as supervisory styles, interpersonal relationships and workers eagerness can have a positive impact on employee motivation and, consequently, on their performance and well-being. To achieve this, knowledge management models such as those presented here can be applied. This model generates diagnoses of motivation and recommendations for improvement, both systematically and scientifically. Consequently, it is especially useful for managers and human resource departments. The proposed model can be adapted to different kinds of professional groups, including those in library and documentation services. The suitability, reliability and usefulness of the proposed model have been empirically checked through case studies with 92 students and 166 professionals. The positive results allow us to conclude that the model is effective and useful for assessing and improving motivation.

  15. The ERICAM model: a proposal for amelioration of nuclear liability by funding on the capital markets

    International Nuclear Information System (INIS)

    Tyran, J.R.

    1995-01-01

    The ERICAM model (Environmental Risk Internalization through Capital Markets) includes the capital markets as a source contributing to the coverage of risks due to nuclear activites, thus enhancing the effectiveness and functions of the nuclear liability law. The model proposed will allow higher amounts for compensation and will increase financial security, flow of information, and efficient use of resources. The implementation of the model can be achieved on the financing side by issuing Nuke bonds, linking accident-specific options to government bonds. This will essentially increase the risk coverage compared to present means, and will be a pin-pointed addition to the existing layer system. There are three institutions proposed to act as mediators in the implementation of the model: A government authority to supervise the trade in Nuke bonds. Risk-bearing associations in oder to enhance the model's efficiency, and to reduce transaction costs. Rating agencies that will reduce the expenditure for information. (orig./HP) [de

  16. Proposal for a Method for Business Model Performance Assessment: Toward an Experimentation Tool for Business Model Innovation

    Directory of Open Access Journals (Sweden)

    Antonio Batocchio

    2017-04-01

    Full Text Available The representation of business models has been recently widespread, especially in the pursuit of innovation. However, defining a company’s business model is sometimes limited to discussion and debates. This study observes the need for performance measurement so that business models can be data-driven. To meet this goal, the work proposed as a hypothesis the creation of a method that combines the practices of the Balanced Scorecard with a method of business models representation – the Business Model Canvas. Such a combination was based on study of conceptual adaptation, resulting in an application roadmap. A case study application was performed to check the functionality of the proposition, focusing on startup organizations. It was concluded that based on the performance assessment of the business model it is possible to propose the search for change through experimentation, a path that can lead to business model innovation.

  17. A proposed strategy for the validation of ground-water flow and solute transport models

    International Nuclear Information System (INIS)

    Davis, P.A.; Goodrich, M.T.

    1991-01-01

    Ground-water flow and transport models can be thought of as a combination of conceptual and mathematical models and the data that characterize a given system. The judgment of the validity or invalidity of a model depends both on the adequacy of the data and the model structure (i.e., the conceptual and mathematical model). This report proposes a validation strategy for testing both components independently. The strategy is based on the philosophy that a model cannot be proven valid, only invalid or not invalid. In addition, the authors believe that a model should not be judged in absence of its intended purpose. Hence, a flow and transport model may be invalid for one purpose but not invalid for another. 9 refs

  18. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  19. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  20. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  1. Two-Dimensional Model Test Study of New Western Breakwater Proposal for Port of Hanstholm

    OpenAIRE

    Eldrup, Mads Røge; Andersen, Thomas Lykke

    2016-01-01

    The present report presents results from a two-dimensional model test study carried out at Aalborg University in December 2016 with the proposed trunk section for the new western breakwater in Port of Hanstholm. The objectives of the model tests were to study the stability of the armour layer, toe erosion, overtopping and transmission. The scale used for the model tests was 1:61.5. Unless otherwise specified all values given in this report are prototype values converted from the model to prot...

  2. Evaluation of a proposed optimization method for discrete-event simulation models

    Directory of Open Access Journals (Sweden)

    Alexandre Ferreira de Pinho

    2012-12-01

    Full Text Available Optimization methods combined with computer-based simulation have been utilized in a wide range of manufacturing applications. However, in terms of current technology, these methods exhibit low performance levels which are only able to manipulate a single decision variable at a time. Thus, the objective of this article is to evaluate a proposed optimization method for discrete-event simulation models based on genetic algorithms which exhibits more efficiency in relation to computational time when compared to software packages on the market. It should be emphasized that the variable's response quality will not be altered; that is, the proposed method will maintain the solutions' effectiveness. Thus, the study draws a comparison between the proposed method and that of a simulation instrument already available on the market and has been examined in academic literature. Conclusions are presented, confirming the proposed optimization method's efficiency.

  3. Proposal of a Model for effective Management and Development of virtual Teams

    Directory of Open Access Journals (Sweden)

    Petr Skyrik

    2010-10-01

    Full Text Available The main aim of this paper is to present a pilot proposal of a model of “Virtual Development Management System” (ViDeMaS which will facilitate more effective management and development of virtual teams. Management and development of virtual teams is not a simple concept. It comprises a body of knowledge from a number of fields and scientific disciplines. The complexity of the concept may not be simplified as it is absolutely essential for full understanding of its nature. In order to gain better orientation in the concept, different perspectives will be used in the description of the model, which will enable us to achieve the goal of the work and to present the main results of the work (creation of a model for Virtual Development Management System. The present paper thus describes from different perspectives the proposal of a sufficiently detailed and complex model that may be utilized both on theoretical and application level.

  4. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  5. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  6. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  7. DEVELOPING AND PROPOSING A CONCEPTUAL MODEL OF THE FLOW EXPERIENCE DURING ONLINE INFORMATION SEARCH

    Directory of Open Access Journals (Sweden)

    Lazoc Alina

    2012-07-01

    Full Text Available Information search is an essential part of the consumer`s decision making process. The online medium offers new opportunities and challenges for information search activities (in and outside the marketing context. We are interested in the way human information experiences and behaviors are affected by this. Very often online games and social web activities are perceived as challenging, engaging and enjoyable, while online information search is far below this evaluation. Our research proposal implies that using the online medium for information search may provoke enjoyable experiences through the flow state, which may in turn positively influence an individual`s exploratory information behavior and encourage his/her pro-active market behavior. The present study sets out to improve the understanding of the online medium`s impact on human`s exploratory behavior. We hypothesize that the inclusion of the online flow experience in our research model will better explain exploratory information search behaviors. A 11-component conceptual framework is proposed to explain the manifestations of flow, its personal and technological determinants and its behavioral consequence in the context of online information search. Our research has the primary purpose to present an integrated online flow model. Its secondary objective is to stimulate extended research in the area of informational behaviors in the digital age. The paper is organized in three sections. In the first section we briefly report the analysis results of the most relevant online flow theory literature and, drawing on it, we are trying to identify variables and relationships among these. In the second part we propose a research model and use prior flow models to specify a range of testable hypothesis. Drawing on the conceptual model developed, the last section of our study presents the final conclusions and proposes further steps in evaluating the model`s validity. Future research directions

  8. The New Digital Media Value Network: Proposing an Interactive Model of Digital Media Value Activities

    Directory of Open Access Journals (Sweden)

    Sylvia Chan-Olmsted

    2016-07-01

    Full Text Available This study models the dynamic nature of today’s media markets using the framework of value-adding activities in the provision and consumption of media products. The proposed user-centric approach introduces the notion that the actions of external users, social media, and interfaces affect the internal value activities of media firms via a feedback loop, and therefore should themselves be considered value activities. The model also suggests a more comprehensive list of indicators for value assessment.

  9. Space-Time Uncertainty and Cosmology: a Proposed Quantum Model of the Universe [ 245Kb

    Directory of Open Access Journals (Sweden)

    Tosto S.

    2013-10-01

    Full Text Available The paper introduces a cosmological model of the quantum universe. The aim of the model is (i to identify the possible mechanism that governs the matter/antimatter ratio existing in the universe and concurrently to propose (ii a reasonable growth mechanism of the universe and (iii a possible explanation of the dark energy. The concept of timespace uncertainty, on which is based the present quantum approach, has been proven able to bridge quantum mechanics and relativity.

  10. Comparison of two analytical models of blanking and proposal of a new model

    NARCIS (Netherlands)

    Klingenberg, W; Singh, UP

    With the development of accurate Finite Element models of the punching/blanking process by the present authors and other researchers, important possibilities emerged to model and analyse the process in a research environment. However, Finite Element models are less well suited for use in a

  11. Imperceptible reversible watermarking of radiographic images based on quantum noise masking.

    Science.gov (United States)

    Pan, Wei; Bouslimi, Dalel; Karasad, Mohamed; Cozic, Michel; Coatrieux, Gouenou

    2018-07-01

    of different anatomical structures show that our scheme induces a very low image distortion (PSNR∼ 76.5 dB) for a relatively important capacity (capacity∼ 0.02 bits of message per pixel). The proposed watermarking scheme, while being reversible, preserves the diagnosis value of radiographic images by masking the watermark into the quantum noise. As theoretically and experimentally established our scheme offers a good capacity/image quality compromise that can support different watermarking based security services such as integrity and authenticity control. The watermark can be kept into the image during the interpretation of the image, offering thus a continuous protection. Such a masking strategy can be seen as the first psychovisual model for radiographic images. The reversibility allows the watermark update when necessary. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  13. Proposal for intake model for workers at IPEN-CNEN/SP who handle 131 I

    International Nuclear Information System (INIS)

    Todo, A.S.; Potiens Junior, A.J.; Gaburo, J.C.; Sanches, M.P.; Oliveira, E.M.

    1997-01-01

    The intake model for the two groups of workers at IPEN-CNEN/SP is presented. They handle iodine compounds during the processing of irradiated targets and at labeling of radiopharmaceutical compounds. The intake model for the workers are proposed from the knowledge of the activities carried out in the plant and the internal monitoring program of the workers. In this study, the intake is considered to be taken uniformly during the days of major activities carried out by the workers. In practice, the application of this model has be shown suitable, for the studied groups

  14. PTSD's latent structure in Malaysian tsunami victims: assessing the newly proposed Dysphoric Arousal model.

    Science.gov (United States)

    Armour, Cherie; Raudzah Ghazali, Siti; Elklit, Ask

    2013-03-30

    The underlying latent structure of Posttraumatic Stress Disorder (PTSD) is widely researched. However, despite a plethora of factor analytic studies, no single model has consistently been shown as superior to alternative models. The two most often supported models are the Emotional Numbing and the Dysphoria models. However, a recently proposed five-factor Dysphoric Arousal model has been gathering support over and above existing models. Data for the current study were gathered from Malaysian Tsunami survivors (N=250). Three competing models (Emotional Numbing/Dysphoria/Dysphoric Arousal) were specified and estimated using Confirmatory Factor Analysis (CFA). The Dysphoria model provided superior fit to the data compared to the Emotional Numbing model. However, using chi-square difference tests, the Dysphoric Arousal model showed a superior fit compared to both the Emotional Numbing and Dysphoria models. In conclusion, the current results suggest that the Dysphoric Arousal model better represents PTSD's latent structure and that items measuring sleeping difficulties, irritability/anger and concentration difficulties form a separate, unique PTSD factor. These results are discussed in relation to the role of Hyperarousal in PTSD's on-going symptom maintenance and in relation to the DSM-5. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Monte Carlo simulation for radiographic applications

    International Nuclear Information System (INIS)

    Tillack, G.R.; Bellon, C.

    2003-01-01

    Standard radiography simulators are based on the attenuation law complemented by built-up-factors (BUF) to describe the interaction of radiation with material. The assumption of BUF implies that scattered radiation reduces only the contrast in radiographic images. This simplification holds for a wide range of applications like weld inspection as known from practical experience. But only a detailed description of the different underlying interaction mechanisms is capable to explain effects like mottling or others that every radiographer has experienced in practice. The application of Monte Carlo models is capable to handle primary and secondary interaction mechanisms contributing to the image formation process like photon interactions (absorption, incoherent and coherent scattering including electron-binding effects, pair production) and electron interactions (electron tracing including X-Ray fluorescence and Bremsstrahlung production). It opens up possibilities like the separation of influencing factors and the understanding of the functioning of intensifying screen used in film radiography. The paper discusses the opportunities in applying the Monte Carlo method to investigate special features in radiography in terms of selected examples. (orig.) [de

  16. Radiographic protocol and normal anatomy of the hind feet in the white rhinoceros (Ceratotherium simum).

    Science.gov (United States)

    Dudley, Robert J; Wood, Simon P; Hutchinson, John R; Weller, Renate

    2015-01-01

    Foot pathology is a common and important health concern in captive rhinoceroses worldwide, but osteopathologies are rarely diagnosed, partly because of a lack of radiographic protocols. Here, we aimed to develop the first radiographic protocol for rhinoceros feet and describe the radiographic anatomy of the white rhinoceros (Ceratotherium simum) hind foot (pes). Computed tomographic images were obtained of nine cadaver pedes from seven different white rhinoceroses and assessed for pathology. A single foot deemed free of pathology was radiographed using a range of different projections and exposures to determine the best protocol. 3D models were produced from the CT images and were displayed with the real radiographs to describe the normal radiographic anatomy of the white rhinoceros pes. An optimal radiographic projection was determined for each bone in the rhinoceros pes focusing on highlighting areas where pathology has been previously described. The projections deemed to be most useful were D60Pr-PlDiO (digit III), D45Pr45M-PlDiLO (digit II), and D40Pr35L-PlDiLO (digit IV). The primary beam was centered 5-7 cm proximal to the cuticle on the digit of interest. Articular surfaces, ridges, grooves, tubercles, processes and fossae were identified. The radiographic protocol we have developed along with the normal radiographic anatomy we have described will allow for more accessible and effective diagnosis of white rhinoceros foot osteopathologies. © 2014 American College of Veterinary Radiology.

  17. Study of the sensitivity of wire image quality indicators (IQI) used in radiographic testing of metals and alloys

    International Nuclear Information System (INIS)

    Sanchez, W.; Oki, H.

    1974-01-01

    Radiographic sensitivity is defined and its mathematical expresion is derived in order to justify the use of image quality indicators-IQI- formed by wires of different diameters which represent the radiographic quality. It is demonstrated that IQI sensibility is not related to the minimum dimensions of the metallic discontinuities that may be detected in radiographic tests. The experimental results are in good agreement whith the mathematical formulation proposed

  18. A proposed model for the transfer of environmental tritium to man and tritium metabolism in model animals

    International Nuclear Information System (INIS)

    Saito, Masahiro; Ishida, M.R.

    1987-01-01

    To evaluate the accumulated dose in human bodies due to the environmental tritium, it is of required to establish an adequate model for the tritium transfer from the environment to man and to obtain enough information on the metabolic behaviour of tritium in animal bodies using model animal system. In this report, first we describe about a proposed model for the transfer of environmental tritium to man and secondly mention briefly about the recent works on the tritium metabolism in newborn animals which have been treated as a model system of tritium intake through food chain. (author)

  19. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  20. A proposal for operator team behavior model and operator's thinking mechanism

    International Nuclear Information System (INIS)

    Yoshimura, Seiichi; Takano, Kenichi; Sasou, Kunihide

    1995-01-01

    Operating environment in huge systems like nuclear power plants or airplanes is changing rapidly with the advance of computer technology. It is necessary to elucidate thinking process of operators and decision-making process of an operator team in abnormal situations, in order to prevent human errors under such environment. The Central Research Institute of Electric Power Industry is promoting a research project to establish human error prevention countermeasures by modeling and simulating the thinking process of operators and decision-making process of an operator team. In the previous paper, application of multilevel flow modeling was proposed to a mental model which conducts future prediction and cause identification, and the characteristics were verified by experienced plant operators. In this paper, an operator team behavior model and a fundamental operator's thinking mechanism especially 'situation understanding' are proposed, and the proposals are evaluated by experiments using a full-scale simulator. The results reveal that some assumptions such as 'communication is done between a leader and a follower' are almost appropriate and that the situation understanding can be represented by 'probable candidates for cause, determination of a parameter which changes when an event occurs, determination of parameters which are influenced by the change of the previous parameter, determination of a principal parameter and future prediction of the principal parameter'. (author)

  1. THE PROPOSED MODEL OF COLLABORATIVE VIRTUAL LEARNING ENVIRONMENT FOR INTRODUCTORY PROGRAMMING COURSE

    Directory of Open Access Journals (Sweden)

    Mahfudzah OTHMAN

    2012-01-01

    Full Text Available This paper discusses the proposed model of the collaborative virtual learning system for the introductory computer programming course which uses one of the collaborative learning techniques known as the “Think-Pair-Share”. The main objective of this study is to design a model for an online learning system that facilitates the collaborative learning activities in a virtual environment such as online communications and pair or small group discussions. In order to model the virtual learning environment, the RUP methodology has been used where it involves the data collection phase and the analysis and design phase. Fifty respondents have been randomly selected to participate in the data collection phase to investigate the students’ interest and learning styles as well as their learning preferences. The results have shown the needs for the development of online small group discussions that can be used as an alternative learning style for programming courses. The proposed design of the virtual learning system named as the Online Collaborative Learning System or OCLS is being depicted using the object-oriented models which are the use-case model and class diagram in order to show the concise processes of virtual “Think-Pair-Share” collaborative activities. The “Think-Pair-Share” collaborative learning technique that is being used in this model has been chosen because of its simplicity and relatively low-risk. This paper also presents the proposed model of the system’s architecture that will become the guidelines for the physical development of OCLS using the web-based applications.

  2. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    work and the design of the mammography units, breast screening radiographers are often subjected to frequent bending and twisting, static working postures, forceful movements and repetitive work. These are factors which have all been related to muscular problems. It is possible that these factors may have a cumulative effect of wear and tear on the musculoskeletal system of radiographers thus possibly aggravating existing or past injuries and paving the way for new ones. It is important therefore that recommendations are proposed to further the ergonomic design of mammography units, the training, the working practices and conditions of the radiographers. Both causal and contributory factors present in the workplace, regardless of whether the original injury was caused in performing breast screening, general radiography or actually outside work should be addressed. Recommendations are made in order to reduce the adoption of poor and awkward postures while breast screening in the future and therefore reduce the amount of musculoskeletal discomfort experienced by radiographers. All changes to the workplace should be initially conducted on a trial basis and monitored to determine their success to ensure that they represent no additional problems

  3. THEORETICAL AND EXPERIMENTAL CONTRIBUTIONS CONCERNING THE PROPOSED MODEL FOR THE DISC-TYPED ROTARY ULTRASONIC MOTOR

    Directory of Open Access Journals (Sweden)

    Oana CHIVU

    2010-10-01

    Full Text Available In this work the proposed model for type-disk, ultrasonic motor rotating, elliptic movement to surface beam. A sinusoidal vibration of the vertical displacement in the z-direction, Assume that the vertical displacement of the neutral plane, equals the product of the slope of the neutral plane and half of the beam height, the tangential velocity vs at the upper surface is given.

  4. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  5. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  6. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  7. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  8. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  9. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  10. Proposal of a Modelling of the Innovation Process in an International Manufacturing Company

    Directory of Open Access Journals (Sweden)

    Pauline Lacom

    2017-07-01

    Full Text Available Nowadays, to cope with the competition, and to ensure the durability of their activities, companies have to be able to innovate. Manufacturing companies operating in a B2B market often perceive innovation as a technological result. However, innovation is often more characterized as a process. The needs of the users, and not only the technology, can achieve innovation. In this context, our paper intends to determine how to involve better the users in the innovation process of an international manufacturing company, which is, according to us, representative of the current manufacturing companies. The aim of our research paper is to help manufacturing companies to manage innovation led by users, and to implement their innovation process so that they will be able to set up specific tools for each action of the process. The study proposes a diagram-based language Structured Analysis and Design Technique (SADT that is based on the normative guide FD X50-271 of the French national organization for standardization (AFNOR. The SADT model we propose usefully complements this guide, to make the innovation process more understandable, practical and operational, for manufacturing companies, which are often helpless when faced with the subject. A critical analysis of the model we propose completed in a manufacturing company through semi-structured interviews of the innovation team and questionnaire for all the employees shows the application of the model in the company.

  11. Stress, autonomic imbalance, and the prediction of metabolic risk: A model and a proposal for research.

    Science.gov (United States)

    Wulsin, Lawson; Herman, James; Thayer, Julian F

    2018-03-01

    Devising novel prevention strategies for metabolic disorders will depend in part on the careful elucidation of the common pathways for developing metabolic risks. The neurovisceral integration model has proposed that autonomic imbalance plays an important role in the pathway from acute and chronic stress to cardiovascular disease. Though generally overlooked by clinicians, autonomic imbalance (sympathetic overactivity and/or parasympathetic underactivity) can be measured and modified by methods that are available in primary care. This review applies the neurovisceral integration concept to the clinical setting by proposing that autonomic imbalance plays a primary role in the development of metabolic risks. We present a testable model, a systematic review of the evidence in support of autonomic imbalance as a predictor for metabolic risks, and specific approaches to test this model as a guide to future research on the role of stress in metabolic disorders. We propose that autonomic imbalance deserves consideration by researchers, clinicians, and policymakers as a target for early interventions to prevent metabolic disorders. Published by Elsevier Ltd.

  12. A proposed defect tracking model for classifying the inserted defect reports to enhance software quality control.

    Science.gov (United States)

    Sultan, Torky; Khedr, Ayman E; Sayed, Mostafa

    2013-01-01

    NONE DECLARED Defect tracking systems play an important role in the software development organizations as they can store historical information about defects. There are many research in defect tracking models and systems to enhance their capabilities to be more specifically tracking, and were adopted with new technology. Furthermore, there are different studies in classifying bugs in a step by step method to have clear perception and applicable method in detecting such bugs. This paper shows a new proposed defect tracking model for the purpose of classifying the inserted defects reports in a step by step method for more enhancement of the software quality.

  13. Stereoscopic radiographic images with gamma source encoding

    International Nuclear Information System (INIS)

    Strocovsky, S.G.; Otero, D

    2012-01-01

    Conventional radiography with X-ray tube has several drawbacks, as the compromise between the size of the focal spot and the fluence. The finite dimensions of the focal spot impose a limit to the spatial resolution. Gamma radiography uses gamma-ray sources which surpass in size, portability and simplicity to X-ray tubes. However, its low intrinsic fluence forces to use extended sources that also degrade the spatial resolution. In this work, we show the principles of a new radiographic technique that overcomes the limitations associated with the finite dimensions of X-ray sources, and that offers additional benefits to conventional techniques. The new technique called coding source imaging (CSI), is based on the use of extended sources, edge-encoding of radiation and differential detection. The mathematical principles and the method of images reconstruction with the new proposed technique are explained in the present work. Analytical calculations were made to determine the maximum spatial resolution and the variables on which it depends. The CSI technique was tested by means of Monte Carlo simulations with sets of spherical objects. We show that CSI has stereoscopic capabilities and it can resolve objects smaller than the source size. The CSI decoding algorithm reconstructs simultaneously four different projections from the same object, while conventional radiography produces only one projection per acquisition. Projections are located in separate image fields on the detector plane. Our results show it is possible to apply an extremely simple radiographic technique with extended sources, and get 3D information of the attenuation coefficient distribution for simple geometry objects in a single acquisition. The results are promising enough to evaluate the possibility of future research with more complex objects typical of medical diagnostic radiography and industrial gamma radiography (author)

  14. [Impact of small-area context on health: proposing a conceptual model].

    Science.gov (United States)

    Voigtländer, S; Mielck, A; Razum, O

    2012-11-01

    Recent empirical studies stress the impact of features related to the small-area context on individual health. However, so far there exists no standard explanatory model that integrates the different kinds of such features and that conceptualises their relation to individual characteristics of social inequality. A review of theoretical publications on the relationship between social position and health as well as existing conceptual models for the impact of features related to the small-area context on health was undertaken. In the present article we propose a conceptual model for the health impact of the small-area context. This model conceptualises the location of residence as one dimension of social inequality that affects health through the resources as well as stressors which are inherent in the small-area context. The proposed conceptual model offers an orientation for future empirical studies and can serve as a basis for further discussions concerning the health relevance of the small-area context. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Assessment of nutritional status in the elderly: a proposed function-driven model.

    Science.gov (United States)

    Engelheart, Stina; Brummer, Robert

    2018-01-01

    There is no accepted or standardized definition of 'malnutrition'. Hence, there is also no definition of what constitutes an adequate nutritional status. In elderly people, assessment of nutritional status is complex and is complicated by multi-morbidity and disabilities combined with nutrition-related problems, such as dysphagia, decreased appetite, fatigue, and muscle weakness. We propose a nutritional status model that presents nutritional status from a comprehensive functional perspective. This model visualizes the complexity of the nutritional status in elderly people. The presented model could be interpreted as the nutritional status is conditional to a person's optimal function or situation. Another way of looking at it might be that a person's nutritional status affects his or her optimal situation. The proposed model includes four domains: (1) physical function and capacity; (2) health and somatic disorders; (3) food and nutrition; and (4) cognitive, affective, and sensory function. Each domain has a major impact on nutritional status, which in turn has a major impact on the outcome of each domain. Nutritional status is a multifaceted concept and there exist several knowledge gaps in the diagnosis, prevention, and optimization of treatment of inadequate nutritional status in elderly people. The nutritional status model may be useful in nutritional assessment research, as well as in the clinical setting.

  16. A proposed model of psychodynamic psychotherapy linked to Erik Erikson's eight stages of psychosocial development.

    Science.gov (United States)

    Knight, Zelda Gillian

    2017-09-01

    Just as Freud used stages of psychosexual development to ground his model of psychoanalysis, it is possible to do the same with Erik Erikson's stages of development with regards to a model of psychodynamic psychotherapy. This paper proposes an eight-stage model of psychodynamic psychotherapy linked to Erik Erikson's eight stages of psychosocial development. Various suggestions are offered. One such suggestion is that as each of Erikson's developmental stages is triggered by a crisis, in therapy it is triggered by the client's search. The resolution of the search often leads to the development of another search, which implies that the therapy process comprises a series of searches. This idea of a series of searches and resolutions leads to the understanding that identity is developmental and therapy is a space in which a new sense of identity may emerge. The notion of hope is linked to Erikson's stage of Basic Trust and the proposed model of therapy views hope and trust as essential for the therapy process. Two clinical vignettes are offered to illustrate these ideas. Psychotherapy can be approached as an eight-stage process and linked to Erikson's eight stages model of development. Psychotherapy may be viewed as a series of searches and thus as a developmental stage resolution process, which leads to the understanding that identity is ongoing throughout the life span. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1988-01-01

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  18. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  19. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H; Brostroem, L A; Aparisi, T

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  20. Computational simulation of radiographic film

    International Nuclear Information System (INIS)

    Goncalves, Elicardo A. de S.; Santos, Marcio H. dos; Anjos, Marcelino J.; Oliveira, Luis F. de

    2013-01-01

    The composition of a radiographic film gives its values of speed, spatial resolution and base density. The technical knowledge allows to predict how a film with a known composition works, and simulate how this film will work with changes in composition and exposure. In this paper, characterization of films composed by different emulsions was realized, in a way to know the characteristic curve, and to study how the format, organization and concentration of silver salt crystals set the radiographic film images.This work aims to increase an existing simulator, where parallel programming was used to simulate X-ray fluorescence processes. The setup of source and X-ray interactions with objects stills the same, and the detector constructed in this work was placed to form images. At first, considering the approach that the film is a square matrix where each element has a specific quantity of silver grains, that each grain fills a specific area, and that each interaction to radiation transforms a salt silver grain in to metallic silver grain (black grain), we have a blackening standard, and it should show how is the behavior of a optic density in a specific area of the film. Each matrix element has a degree of blackening, and it is proportional to the black grains area. (author)

  1. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  2. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  3. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  4. Energetic models: a proposal of integrated planning; Modelos energeticos: uma proposta de planejamento integrado

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Junior, Amaro Olimpio; Soares, Jeferson Borghetti; Araujo, Mauro Almeida [Empresa de Pesquisa Energetica (EPE), Brasilia, DF (Brazil)]. E-mails: amaro.pereira@epe.gov.br; jeferson.soares@epe.gov.br; mauro.almeida@epe.gov.br; La Rovere, Emilio Lebre [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Planejamento Estrategico]. E-mail: emilio@ppe.ufrj.br; Costa, Ricardo Cunha da [Banco Nacional de Desenvolvimento Economico e Social (BNDES), Rio de Janeiro, RJ (Brazil)]. E-mail: rcco@bndes.gov.br

    2006-07-01

    Top-down, bottom-up and hybrid models for representing energy system are often used in energy planning. However, in developing countries some of their assumptions do not apply: markets are not developed and not competitive; informal economies are representative; there are huge social inequalities; regulatory changes are not completed; there exist constraints to capital flow; etc. All theses problems need to be well represented in order to have energy analysis more consistent. In this work, it is proposed a multi-sector dynamic recursive model that incorporates consumer behaviors, energy policies, technical progress and factors of production substitution. The static result feeds detailed energy models that provide updated values for the next step equilibrium. This approach takes advantages not only in terms of computation but also in terms of the consistence between economy and energy modeling. (author)

  5. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  6. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  7. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  8. Citygml and the Streets of New York - a Proposal for Detailed Street Space Modelling

    Science.gov (United States)

    Beil, C.; Kolbe, T. H.

    2017-10-01

    Three-dimensional semantic city models are increasingly used for the analysis of large urban areas. Until now the focus has mostly been on buildings. Nonetheless many applications could also benefit from detailed models of public street space for further analysis. However, there are only few guidelines for representing roads within city models. Therefore, related standards dealing with street modelling are examined and discussed. Nearly all street representations are based on linear abstractions. However, there are many use cases that require or would benefit from the detailed geometrical and semantic representation of street space. A variety of potential applications for detailed street space models are presented. Subsequently, based on related standards as well as on user requirements, a concept for a CityGML-compliant representation of street space in multiple levels of detail is developed. In the course of this process, the CityGML Transportation model of the currently valid OGC standard CityGML2.0 is examined to discover possibilities for further developments. Moreover, a number of improvements are presented. Finally, based on open data sources, the proposed concept is implemented within a semantic 3D city model of New York City generating a detailed 3D street space model for the entire city. As a result, 11 thematic classes, such as roadbeds, sidewalks or traffic islands are generated and enriched with a large number of thematic attributes.

  9. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    work and the design of the mammography units, breast screening radiographers are often subjected to frequent bending and twisting, static working postures, forceful movements and repetitive work. These are factors which have all been related to muscular problems. It is possible that these factors may have a cumulative effect of wear and tear on the musculoskeletal system of radiographers thus possibly aggravating existing or past injuries and paving the way for new ones. It is important therefore that recommendations are proposed to further the ergonomic design of mammography units, the training, the working practices and conditions of the radiographers. Both causal and contributory factors present in the workplace, regardless of whether the original injury was caused in performing breast screening, general radiography or actually outside work should be addressed. (abstract truncated)

  10. Research in medical imaging and the role of the consultant radiographer: A discussion

    International Nuclear Information System (INIS)

    Reeves, Pauline J.

    2008-01-01

    This article examines the need for research in radiography as a means to provide the evidence base for radiographic practice. The review examines the role of the consultant radiographer in providing potential research leadership and outlines possible avenues for research. The article uses three main themes to set out its proposals: - The need for patient focus. - The need for a greater mix of research methods and, specifically, more studies which utilise qualitative methods. - The need for consultant leadership in research and some potential studies. The article concludes by arguing the need for a greater academic community in radiography with consultant radiographers stepping up to play their part in that community

  11. Chest radiographic abnormalities in HIV-infected African children: a longitudinal study.

    Science.gov (United States)

    Pitcher, Richard D; Lombard, Carl J; Cotton, Mark F; Beningfield, Stephen J; Workman, Lesley; Zar, Heather J

    2015-09-01

    There is limited knowledge of chest radiographic abnormalities over time in HIV-infected children in resource-limited settings. To investigate the natural history of chest radiographic abnormalities in HIV-infected African children, and the impact of antiretroviral therapy (ART). Prospective longitudinal study of the association of chest radiographic findings with clinical and immunological parameters. Chest radiographs were performed at enrolment, 6-monthly, when initiating ART and if indicated clinically. Radiographic abnormalities were classified as normal, mild or moderate severity and considered persistent if present for 6 consecutive months or longer. An ordinal multiple logistic regression model assessed the association of enrolment and time-dependent variables with temporal radiographic findings. 258 children (median (IQR) age: 28 (13-51) months; median CD4+%: 21 (15-24)) were followed for a median of 24 (18-42) months. 70 (27%) were on ART at enrolment; 130 (50%) (median age: 33 (18-56) months) commenced ART during the study. 154 (60%) had persistent severe radiographic abnormalities, with median duration 18 (6-24) months. Among children on ART, 69% of radiographic changes across all 6-month transition periods were improvements, compared with 45% in those not on ART. Radiographic severity was associated with previous radiographic severity (OR=120.80; 95% CI 68.71 to 212.38), lack of ART (OR=1.72; 95% CI 1.29 to 2.27), enrolment age ART was beneficial, reducing the risk of radiographic deterioration or increasing the likelihood of radiological improvement. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. [Social determinants of odontalgia in epidemiological studies: theoretical review and proposed conceptual model].

    Science.gov (United States)

    Bastos, João Luiz Dornelles; Gigante, Denise Petrucci; Peres, Karen Glazer; Nedel, Fúlvio Borges

    2007-01-01

    The epidemiological literature has been limited by the absence of a theoretical framework reflecting the complexity of causal mechanisms for the occurrence of health phenomena / disease conditions. In the field of oral epidemiology, such lack of theory also prevails, since dental caries the leading topic in oral research has been often studied through a biological and reductionist viewpoint. One of the most important consequences of dental caries is dental pain (odontalgia), which has received little attention in studies with sophisticated theoretical models and powerful designs to establish causal relationships. The purpose of this study is to review the scientific literature on the determinants of odontalgia and to discuss theories proposed for the explanation of the phenomenon. Conceptual models and emerging theories on the social determinants of oral health are revised, in an attempt to build up links with the bio-psychosocial pain model, proposing a more elaborate causal model for odontalgia. The framework suggests causal pathways between social structure and oral health through material, psychosocial and behavioral pathways. Aspects of the social structure are highlighted in order to relate them to odontalgia, stressing their importance in discussions of causal relationships in oral health research.

  13. Proposal of custom made wrist orthoses based on 3D modelling and 3D printing.

    Science.gov (United States)

    Abreu de Souza, Mauren; Schmitz, Cristiane; Marega Pinhel, Marcelo; Palma Setti, Joao A; Nohama, Percy

    2017-07-01

    Accessibility to three-dimensional (3D) technologies, such as 3D scanning systems and additive manufacturing (like 3D printers), allows a variety of 3D applications. For medical applications in particular, these modalities are gaining a lot of attention enabling several opportunities for healthcare applications. The literature brings several cases applying both technologies, but none of them focus on the spreading of how this technology could benefit the health segment. This paper proposes a new methodology, which employs both 3D modelling and 3D printing for building orthoses, which could better fit the demands of different patients. Additionally, there is an opportunity for sharing expertise, as it represents a trendy in terms of the maker-movement. Therefore, as a result of the proposed approach, we present a case study based on a volunteer who needs an immobilization orthosis, which was built for exemplification of the whole process. This proposal also employs freely available 3D models and software, having a strong social impact. As a result, it enables the implementation and effective usability for a variety of built to fit solutions, hitching useful and smarter technologies for the healthcare sector.

  14. A Proposed Analytical Model for Integrated Pick-and-Sort Systems

    Directory of Open Access Journals (Sweden)

    Recep KIZILASLAN

    2013-11-01

    Full Text Available In this study we present an analytical approach for integration of order picking and sortation operations which are the most important, labour intensive and costly activity for warehouses. Main aim is to investigate order picking and sorting efficiencies under different design issues as a function of order wave size. Integrated analytical model is proposed to estimate the optimum order picking and order sortation efficiency. The model, which has been tested by simulations with different illustrative examples, calculates the optimum wave size that solves the trade-off between picking and sorting operations and makes the order picking and sortations efficiency maximum. Our model also allow system designer to predict the order picking and sorting capacity for different system configurations. This study presents an innovative approach for integrated warehouse operations.

  15. Nanometrology, Standardization and Regulation of Nanomaterials in Brazil: A Proposal for an Analytical-Prospective Model

    Directory of Open Access Journals (Sweden)

    Ana Rusmerg Giménez Ledesma

    2013-05-01

    Full Text Available The main objective of this paper is to propose an analytical-prospective model as a tool to support decision-making processes concerning metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world. In the context of nanotechnology development in Brazil, the motivation for carrying out this research was to identify potential benefits of metrology, standardization and regulation of nanomaterials production, from the perspective of future adoption of the model by the main stakeholders of development of these areas in Brazil. The main results can be summarized as follows: (i an overview of international studies on metrology, standardization and regulation of nanomaterials, and nanoparticles, in special; (ii the analytical-prospective model; and (iii the survey questionnaire and the roadmapping tool for metrology, standardization and regulation of nanomaterials in Brazil, based on international references and ongoing initiatives in the world.

  16. Proposed model for fuel-coolant mixing during a core-melt accident

    International Nuclear Information System (INIS)

    Corradini, M.L.

    1983-01-01

    If complete failure of normal and emergency coolant flow occurs in a light water reactor, fission product decay heat would eventually cause melting of the reactor fuel and cladding. The core melt may then slump into the lower plenum and later into the reactor cavity and contact residual liquid water. A model is proposed to describe the fuel-coolant mixing process upon contact. The model is compared to intermediate scale experiments being conducted at Sandia. The modelling of this mixing process will aid in understanding three important processes: (1) fuel debris sizes upon quenching in water, (2) the hydrogen source term during fuel quench, and (3) the rate of steam production. Additional observations of Sandia data indicate that the steam explosion is affected by this mixing process

  17. Proposal of a congestion control technique in LAN networks using an econometric model ARIMA

    Directory of Open Access Journals (Sweden)

    Joaquín F Sánchez

    2017-01-01

    Full Text Available Hasty software development can produce immediate implementations with source code unnecessarily complex and hardly readable. These small kinds of software decay generate a technical debt that could be big enough to seriously affect future maintenance activities. This work presents an analysis technique for identifying architectural technical debt related to non-uniformity of naming patterns; the technique is based on term frequency over package hierarchies. The proposal has been evaluated on projects of two popular organizations, Apache and Eclipse. The results have shown that most of the projects have frequent occurrences of the proposed naming patterns, and using a graph model and aggregated data could enable the elaboration of simple queries for debt identification. The technique has features that favor its applicability on emergent architectures and agile software development.

  18. Temporal subtraction of chest radiographs compensating pose differences

    Science.gov (United States)

    von Berg, Jens; Dworzak, Jalda; Klinder, Tobias; Manke, Dirk; Kreth, Adrian; Lamecker, Hans; Zachow, Stefan; Lorenz, Cristian

    2011-03-01

    Temporal subtraction techniques using 2D image registration improve the detectability of interval changes from chest radiographs. Although such methods are well known for some time they are not widely used in radiologic practice. The reason is the occurrence of strong pose differences between two acquisitions with a time interval of months to years in between. Such strong perspective differences occur in a reasonable number of cases. They cannot be compensated by available image registration methods and thus mask interval changes to be undetectable. In this paper a method is proposed to estimate a 3D pose difference by the adaptation of a 3D rib cage model to both projections. The difference between both is then compensated for, thus producing a subtraction image with virtually no change in pose. The method generally assumes that no 3D image data is available from the patient. The accuracy of pose estimation is validated with chest phantom images acquired under controlled geometric conditions. A subtle interval change simulated by a piece of plastic foam attached to the phantom becomes visible in subtraction images generated with this technique even at strong angular pose differences like an anterior-posterior inclination of 13 degrees.

  19. Pneumothorax detection in chest radiographs using convolutional neural networks

    Science.gov (United States)

    Blumenfeld, Aviel; Konen, Eli; Greenspan, Hayit

    2018-02-01

    This study presents a computer assisted diagnosis system for the detection of pneumothorax (PTX) in chest radiographs based on a convolutional neural network (CNN) for pixel classification. Using a pixel classification approach allows utilization of the texture information in the local environment of each pixel while training a CNN model on millions of training patches extracted from a relatively small dataset. The proposed system uses a pre-processing step of lung field segmentation to overcome the large variability in the input images coming from a variety of imaging sources and protocols. Using a CNN classification, suspected pixel candidates are extracted within each lung segment. A postprocessing step follows to remove non-physiological suspected regions and noisy connected components. The overall percentage of suspected PTX area was used as a robust global decision for the presence of PTX in each lung. The system was trained on a set of 117 chest x-ray images with ground truth segmentations of the PTX regions. The system was tested on a set of 86 images and reached diagnosis accuracy of AUC=0.95. Overall preliminary results are promising and indicate the growing ability of CAD based systems to detect findings in medical imaging on a clinical level accuracy.

  20. Organizational intellectual capital and the role of the nurse manager: A proposed conceptual model.

    Science.gov (United States)

    Gilbert, Jason H; Von Ah, Diane; Broome, Marion E

    Nurse managers must leverage both the human capital and social capital of the teams they lead in order to produce quality outcomes. Little is known about the relationship between human capital and social capital and how these concepts may work together to produce organizational outcomes through leadership of nurses. The purpose of this article was to explore the concepts of human capital and social capital as they relate to nursing leadership in health care organizations. Specific aims included (a) to synthesize the literature related to human capital and social capital in leadership, (b) to refine the conceptual definitions of human capital and social capital with associated conceptual antecedents and consequences, and (c) to propose a synthesized conceptual model guiding further empirical research of social capital and human capital in nursing leadership. A systematic integrative review of leadership literature using criteria informed by Whittemore and Knafl (2005) was completed. CINAHL Plus with Full Text, Academic Search Premier, Business Source Premier, Health Business FullTEXT, MEDLINE, and PsychINFO databases were searched for the years 1995 to 2016 using terms "human capital," "social capital," and "management." Analysis of conceptual definitions, theoretical and conceptual models, antecedents and consequences, propositions or hypotheses, and empirical support for 37 articles fitting review criteria resulted in the synthesis of the proposed Gilbert Conceptual Model of Organizational Intellectual Capital. The Gilbert Conceptual Model of Organizational Intellectual Capital advances the propositions of human capital theory and social capital theory and is the first model to conceptualize the direct and moderating effects that nurse leaders have on the human capital and social capital of the teams they lead. This model provides a framework for further empirical study and may have implications for practice, organizational policy, and education related to nursing

  1. Design and development of a computer based simulator to support learning of radiographic image quality

    Energy Technology Data Exchange (ETDEWEB)

    Costaridou, L; Pitoura, T; Panayiotakis, G; Pallikarakis, N [Department of Medical Physics, School of Medicine, University of Patras, 265 00 Patras (Greece); Hatzis, K [Institute of Biomedical Technology, Ellinos Stratiotou 50A, 264 41 Patras (Greece)

    1994-12-31

    A training simulator has been developed to offer a structured and functional approach to radiographic imaging procedures and comprehensive understanding of interrelations between physical and technical input parameters of a radiographic imaging system and characteristics of image quality. The system addresses training needs of radiographers and radiology clinicians. The simulator is based on procedural simulation enhanced by a hypertextual model of information organization. It is supported by an image data base, which supplies and enriches the simulator. The simulation is controlled by a browsing facility which corresponds to several hierachical levels of use of the underlying multimodal data base, organized as imaging tasks. Representative tasks are : production of a single radiograph or production of functional sets of radiographs exhibiting parameter effects on image characteristics. System parameters such as patient positioning, focus to patient distance, magnification, field dimensions, focal spot size, tube voltage, tube current and exposure time are under user control. (authors). 7 refs, 2 figs.

  2. Design and development of a computer based simulator to support learning of radiographic image quality

    International Nuclear Information System (INIS)

    Costaridou, L.; Pitoura, T.; Panayiotakis, G.; Pallikarakis, N.; Hatzis, K.

    1994-01-01

    A training simulator has been developed to offer a structured and functional approach to radiographic imaging procedures and comprehensive understanding of interrelations between physical and technical input parameters of a radiographic imaging system and characteristics of image quality. The system addresses training needs of radiographers and radiology clinicians. The simulator is based on procedural simulation enhanced by a hypertextual model of information organization. It is supported by an image data base, which supplies and enriches the simulator. The simulation is controlled by a browsing facility which corresponds to several hierachical levels of use of the underlying multimodal data base, organized as imaging tasks. Representative tasks are : production of a single radiograph or production of functional sets of radiographs exhibiting parameter effects on image characteristics. System parameters such as patient positioning, focus to patient distance, magnification, field dimensions, focal spot size, tube voltage, tube current and exposure time are under user control. (authors)

  3. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  4. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  5. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  6. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  7. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  8. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    Soares, Sergio Damasceno; Sperandio, Augusto Gasparoni

    1994-01-01

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  9. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  10. Glass Foreign Body Hand Radiograph

    Directory of Open Access Journals (Sweden)

    Hamid Ehsani-Nia, DO

    2018-04-01

    Full Text Available History of present illness: A 27-year-old female sustained an injury to her left hand after she tripped and fell on a vase. She presented to the emergency department (ED complaining of pain over the laceration. Upon examination, patient presented with multiple small abrasions of the medial aspect of the left 5thdigit that are minimally tender. Additionally, she has one 0.5cm linear laceration of the medial aspect of the 5thmetacarpal with severe tenderness in the area and palpable underlying foreign body. Significant findings: Left hand plain radiography demonstrated a subcutaneous foreign body medial to the 5thmetacarpal that is radiopaque, trapezoidal in shape, and measures approximately 11mm x 3mm. Discussion: Laceration repairs are amongst the most common procedures in the emergency department; however, consideration for foreign body is often underdiagnosed. Imaging is performed in only about 11% of all traumatic wounds in the ED.1 Of those injuries relating to the hand that are subsequently imaged, about 15% are found to have a foreign body.2,3 Additionally, it is estimated that foreign bodies are present in 7% to 8.7% of all wounds caused by glass objects.4,5 Glass is among the most common foreign bodies in lacerations, and fortunately they are radiopaque and relatively well visualized radiographically. It has been demonstrated that 2mm glass foreign bodies have a 99% detection rate with radiography, and 1mm glass foreign bodies an 83% detection rate.6 Patient perception of foreign body has a positive predictive value of 31%, making it a poor source in influencing clinical decision-making to obtain wound radiographs.3 Clinicians should have a high suspicion for foreign body in lacerations, particularly those caused by glass, and utilize close physical examination and imaging for evaluation. Topics: Radiography, glass, foreign body, trauma

  11. Proposal for a model for competitiveness analysis in environmental sustainability in automotive segment companies

    Directory of Open Access Journals (Sweden)

    Luís Henrique Rodrigues

    2018-06-01

    Full Text Available The competitive landscape for companies has been changing over time, featuring an increase in competitiveness in cost, quality, reliability, agility and more recently by a concern for environmental and social factors. This work aims to propose an exploratory analysis model to evaluate companies’ sustainability competitiveness. The model proposes the grouping of companies into clusters, ranking them according to the adoption of lean manufacturing practices, environmental management and human resources, and allocating them into quadrants according to the higher or lower production of waste in their manufacturing processes. The adherence to the model is made with a sample of automotive segment companies (auto parts and motor vehicle manufacturers. The work is classified as one of a practical nature, exploratory, qualitative, and using the survey method. The conclusion that 37.5% of auto parts companies are grouped into clusters that lead to the reduction of waste, with practices in lean manufacturing and environmental management which adjust to competitive factors in the sustainability of motor vehicle manufacturers, is noteworthy.

  12. Modeling fault rupture hazard for the proposed repository at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Coppersmith, K.J.; Youngs, R.R.

    1992-01-01

    In this paper as part of the Electric Power Research Institute's High Level Waste program, the authors have developed a preliminary probabilistic model for assessing the hazard of fault rupture to the proposed high level waste repository at Yucca Mountain. The model is composed of two parts: the earthquake occurrence model that describes the three-dimensional geometry of earthquake sources and the earthquake recurrence characteristics for all sources in the site vicinity; and the rupture model that describes the probability of coseismic fault rupture of various lengths and amounts of displacement within the repository horizon 350 m below the surface. The latter uses empirical data from normal-faulting earthquakes to relate the rupture dimensions and fault displacement amounts to the magnitude of the earthquake. using a simulation procedure, we allow for earthquake occurrence on all of the earthquake sources in the site vicinity, model the location and displacement due to primary faults, and model the occurrence of secondary faulting in conjunction with primary faulting

  13. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  14. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  15. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  16. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  17. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  18. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  19. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  20. Influence of radiographic contrast media on phagocytosis

    International Nuclear Information System (INIS)

    Rasmussen, F.; Georgsen, J.; Grunnet, N.; Aalborg Sygehus

    1988-01-01

    To evaluate the influence of radiographic contrast media (CM) on human polymorphonuclear leucocytes (PML), the ability of these cells to ingest latex particles after in vitro exposure to five different radiographic contrast media was investigated. All CM inhibited the phagocytic properties of PML. The inhibition was dose dependent. The inhibitory effect was partly due to hyperosmolality but CM specific inhibition was also evident. (orig.)

  1. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  2. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  3. Proposed Core Competencies and Empirical Validation Procedure in Competency Modeling: Confirmation and Classification.

    Science.gov (United States)

    Baczyńska, Anna K; Rowiński, Tomasz; Cybis, Natalia

    2016-01-01

    Competency models provide insight into key skills which are common to many positions in an organization. Moreover, there is a range of competencies that is used by many companies. Researchers have developed core competency terminology to underline their cross-organizational value. The article presents a theoretical model of core competencies consisting of two main higher-order competencies called performance and entrepreneurship. Each of them consists of three elements: the performance competency includes cooperation, organization of work and goal orientation, while entrepreneurship includes innovativeness, calculated risk-taking and pro-activeness. However, there is lack of empirical validation of competency concepts in organizations and this would seem crucial for obtaining reliable results from organizational research. We propose a two-step empirical validation procedure: (1) confirmation factor analysis, and (2) classification of employees. The sample consisted of 636 respondents (M = 44.5; SD = 15.1). Participants were administered a questionnaire developed for the study purpose. The reliability, measured by Cronbach's alpha, ranged from 0.60 to 0.83 for six scales. Next, we tested the model using a confirmatory factor analysis. The two separate, single models of performance and entrepreneurial orientations fit quite well to the data, while a complex model based on the two single concepts needs further research. In the classification of employees based on the two higher order competencies we obtained four main groups of employees. Their profiles relate to those found in the literature, including so-called niche finders and top performers. Some proposal for organizations is discussed.

  4. A Proposed Model for Selecting Measurement Procedures for the Assessment and Treatment of Problem Behavior.

    Science.gov (United States)

    LeBlanc, Linda A; Raetz, Paige B; Sellers, Tyra P; Carr, James E

    2016-03-01

    Practicing behavior analysts frequently assess and treat problem behavior as part of their ongoing job responsibilities. Effective measurement of problem behavior is critical to success in these activities because some measures of problem behavior provide more accurate and complete information about the behavior than others. However, not every measurement procedure is appropriate for every problem behavior and therapeutic circumstance. We summarize the most commonly used measurement procedures, describe the contexts for which they are most appropriate, and propose a clinical decision-making model for selecting measurement produces given certain features of the behavior and constraints of the therapeutic environment.

  5. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  6. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  7. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  8. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  9. Radiographic outcomes among South African coal miners.

    Science.gov (United States)

    Naidoo, Rajen N; Robins, Thomas G; Solomon, A; White, Neil; Franzblau, Alfred

    2004-10-01

    This study, the first to document the prevalence of pneumoconiosis among a living South African coal mining cohort, describes dose-response relationships between coal workers' pneumoconiosis and respirable dust exposure, and relationships between pneumoconiosis and both lung function deterioration and respiratory symptoms. A total of 684 current miners and 188 ex-miners from three bituminous-coal mines in Mpumalanga, South Africa, was studied. Chest radiographs were read according to the International Labour Organization (ILO) classification by two experienced readers, one an accredited National Institute for Occupational Safety and Health (NIOSH) "B" reader. Interviews were conducted to assess symptoms, work histories (also obtained from company records), smoking, and other risk factors. Spirometry was performed by trained technicians. Cumulative respirable dust exposure (CDE) estimates were constructed from historical company-collected sampling and researcher-collected personal dust measurements. kappa-Statistics compared the radiographic outcomes predicted by the two readers. An average profusion score was used in the analysis for the outcomes of interest. Because of possible confounding by employment status, most analyses were stratified on current and ex-miner status. The overall prevalence of pneumoconiosis was low (2%-4%). The degree of agreement between the two readers for profusion was moderate to high (kappa=0.58). A significant association (Pminers only. A significant (Pminers with pneumoconiosis than among those without. Logistic regression models showed no significant relationships between pneumoconiosis and symptoms. The overall prevalence of pneumoconiosis, although significantly associated with CDE, was low. The presence of pneumoconiosis is associated with meaningful health effects, including deterioration in lung function. Intervention measures that control exposure are indicated, to reduce these functional effects.

  10. Proposal of Constraints Analysis Method Based on Network Model for Task Planning

    Science.gov (United States)

    Tomiyama, Tomoe; Sato, Tatsuhiro; Morita, Toyohisa; Sasaki, Toshiro

    Deregulation has been accelerating several activities toward reengineering business processes, such as railway through service and modal shift in logistics. Making those activities successful, business entities have to regulate new business rules or know-how (we call them ‘constraints’). According to the new constraints, they need to manage business resources such as instruments, materials, workers and so on. In this paper, we propose a constraint analysis method to define constraints for task planning of the new business processes. To visualize each constraint's influence on planning, we propose a network model which represents allocation relations between tasks and resources. The network can also represent task ordering relations and resource grouping relations. The proposed method formalizes the way of defining constraints manually as repeatedly checking the network structure and finding conflicts between constraints. Being applied to crew scheduling problems shows that the method can adequately represent and define constraints of some task planning problems with the following fundamental features, (1) specifying work pattern to some resources, (2) restricting the number of resources for some works, (3) requiring multiple resources for some works, (4) prior allocation of some resources to some works and (5) considering the workload balance between resources.

  11. From representing to modelling knowledge: Proposing a two-step training for excellence in concept mapping

    Directory of Open Access Journals (Sweden)

    Joana G. Aguiar

    2017-09-01

    Full Text Available Training users in the concept mapping technique is critical for ensuring a high-quality concept map in terms of graphical structure and content accuracy. However, assessing excellence in concept mapping through structural and content features is a complex task. This paper proposes a two-step sequential training in concept mapping. The first step requires the fulfilment of low-order cognitive objectives (remember, understand and apply to facilitate novices’ development into good Cmappers by honing their knowledge representation skills. The second step requires the fulfilment of high-order cognitive objectives (analyse, evaluate and create to grow good Cmappers into excellent ones through the development of knowledge modelling skills. Based on Bloom’s revised taxonomy and cognitive load theory, this paper presents theoretical accounts to (1 identify the criteria distinguishing good and excellent concept maps, (2 inform instructional tasks for concept map elaboration and (3 propose a prototype for training users on concept mapping combining online and face-to-face activities. The proposed training application and the institutional certification are the next steps for the mature use of concept maps for educational as well as business purposes.

  12. APC-PC Combined Scheme in Gilbert Two State Model: Proposal and Study

    Science.gov (United States)

    Bulo, Yaka; Saring, Yang; Bhunia, Chandan Tilak

    2017-04-01

    In an automatic repeat request (ARQ) scheme, a packet is retransmitted if it gets corrupted due to transmission errors caused by the channel. However, an erroneous packet may contain both erroneous bits and correct bits and hence it may still contain useful information. The receiver may be able to combine this information from multiple erroneous copies to recover the correct packet. Packet combining (PC) is a simple and elegant scheme of error correction in transmitted packet, in which two received copies are XORed to obtain the bit location of erroneous bits. Thereafter, the packet is corrected by bit inversion of bit located as erroneous. Aggressive packet combining (APC) is a logic extension of PC primarily designed for wireless communication with objective of correcting error with low latency. PC offers higher throughput than APC, but PC does not correct double bit errors if occur in same bit location of erroneous copies of the packet. A hybrid technique is proposed to utilize the advantages of both APC and PC while attempting to remove the limitation of both. In the proposed technique, applications of APC-PC on Gilbert two state model has been studied. The simulation results show that the proposed technique offers better throughput than the conventional APC and lesser packet error rate than PC scheme.

  13. Reliable Radiographic Inspection of Flexible Risers for the Oil Industry

    Science.gov (United States)

    Almeida, Rômulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-01

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.

  14. RELIABLE RADIOGRAPHIC INSPECTION OF FLEXIBLE RISERS FOR THE OIL INDUSTRY

    International Nuclear Information System (INIS)

    Almeida, Romulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-01-01

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.

  15. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  16. A model proposal concerning balance scorecard application integrated with resource consumption accounting in enterprise performance management

    Directory of Open Access Journals (Sweden)

    ORHAN ELMACI

    2014-06-01

    Full Text Available The present study intended to investigate the “Balance Scorecard (BSC model integrated with Resource Consumption Accounting (RCA” which helps to evaluate the enterprise as matrix structure in its all parts. It aims to measure how much tangible and intangible values (assets of enterprises contribute to the enterprises. In other words, it measures how effectively, actively, and efficiently these values (assets are used. In short, it aims to measure sustainable competency of enterprises. As expressing the effect of tangible and intangible values (assets of the enterprise on the performance in mathematical and statistical methods is insufficient, it is targeted that RCA Method integrated with BSC model is based on matrix structure and control models. The effects of all complex factors in the enterprise on the performance (productivity and efficiency estimated algorithmically with cause and effect diagram. The contributions of matrix structures for reaching the management functional targets of the enterprises that operate in market competitive environment increasing day to day, is discussed. So in the context of modern management theories, as a contribution to BSC approach which is in the foreground in today’s administrative science of enterprises in matrix organizational structures, multidimensional performance evaluation model -RCA integrated with BSC Model proposal- is presented as strategic planning and strategic evaluation instrument.

  17. A Proposed Model for Measuring Performance of the University-Industry Collaboration in Open Innovation

    Directory of Open Access Journals (Sweden)

    Anca Draghici

    2017-06-01

    Full Text Available The paper aims to present a scientific approach to the creation, testing and validation of a model for performance measurement for university-industry collaboration (UIC. The main idea of the design process is to capitalize on existing success factors, facilitators and opportunities (motivation factors, knowledge transfer channels and identified benefits and to diminish or avoid potential threats and barriers that might interfere with such collaborations. The main purpose of the applied methodology is to identify solutions and measures to overcome the disadvantages, conflicts or risk issues and to facilitate the open innovation of industrial companies and universities. The methodology adopted was differentiated by two perspectives: (1 a business model reflecting the university perspective along with an inventory of key performance indicators (KPIs; (2 a performance measurement model (including performance criteria and indicators and an associated methodology (assimilated to an audit that could help companies increase collaboration with universities in the context of open innovation. In addition, in order to operationalize the proposed model (facilitating practical implementation, an Excel tool has been created to help identifying potential sources of innovation. The main contributions of the research concern the expansion of UICs knowledge to enhance open innovation and to define an effective performance measurement model and instrument (tested and validated by a case study for companies.

  18. The proposed 'concordance-statistic for benefit' provided a useful metric when modeling heterogeneous treatment effects.

    Science.gov (United States)

    van Klaveren, David; Steyerberg, Ewout W; Serruys, Patrick W; Kent, David M

    2018-02-01

    Clinical prediction models that support treatment decisions are usually evaluated for their ability to predict the risk of an outcome rather than treatment benefit-the difference between outcome risk with vs. without therapy. We aimed to define performance metrics for a model's ability to predict treatment benefit. We analyzed data of the Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) trial and of three recombinant tissue plasminogen activator trials. We assessed alternative prediction models with a conventional risk concordance-statistic (c-statistic) and a novel c-statistic for benefit. We defined observed treatment benefit by the outcomes in pairs of patients matched on predicted benefit but discordant for treatment assignment. The 'c-for-benefit' represents the probability that from two randomly chosen matched patient pairs with unequal observed benefit, the pair with greater observed benefit also has a higher predicted benefit. Compared to a model without treatment interactions, the SYNTAX score II had improved ability to discriminate treatment benefit (c-for-benefit 0.590 vs. 0.552), despite having similar risk discrimination (c-statistic 0.725 vs. 0.719). However, for the simplified stroke-thrombolytic predictive instrument (TPI) vs. the original stroke-TPI, the c-for-benefit (0.584 vs. 0.578) was similar. The proposed methodology has the potential to measure a model's ability to predict treatment benefit not captured with conventional performance metrics. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  20. Proposing a model for limiting earning management practices: The case of Jordanian listed firms

    Directory of Open Access Journals (Sweden)

    Dea’a Al-Deen Al-Sraheen

    2016-11-01

    Full Text Available The key objective of this paper is to propose a model for limiting earning management practices among manufacturing firms in Jordan. In order to do so, two independent variables are examined in this paper, namely, political influence and CEO Duality. Discretionary total accruals according to the modified Jones model (1991 was used in order to estimate the level of earnings management, which is the dependent variable. The sample comprised 64 companies for the financial year 2013. The results suggest that a positive and significant association existed among both political influence and CEO duality and earning management. This means that both independent variables exacerbated earnings management. Further research is required to determine what urgent legislation should be developed to restrict the presence of members who have political connections on the board of directors. Also, the need exists for the separation of roles of Chairman and CEO to ensure the independence and complying with the requirements of corporate governance.

  1. Proposed Model for Integrating RAMS Method in the Design Process in Construction

    Directory of Open Access Journals (Sweden)

    Saad Al-Jibouri

    2010-05-01

    Full Text Available There is a growing trend in the Netherlands for outsourcing public construction activities to the private sector through the use of integrated contracts. There is also an increasing emphasis from public clients on the use of RAMS and life cycle costing (LCC in the design process of infrastructural projects to improve the performance of designed systems and optimize the project cost. RAMS is an acronym for `reliability, availability, maintainability and safety' and represents a collection of techniques to provide predictions of the performance targets of the required system. Increasingly, RAMS targets are being specified in invitation to tender or contract documents and the parties responsible for the design are required to provide evidence of its application in their design. Recent evidence from practice, complemented with a literature study, has shown that the knowledge and application of RAMS in infrastructural designs are in their infancy compared with other industrial sectors and many designers in construction do not have the necessary knowledge and experience to apply it. This paper describes a proposed model for the integration of RAMS and LCC into the design process in construction. A variation of the model for the application of RAMS in `design, build, finance and maintain' (DBFM contracts that include maintenance requirements is also proposed. The two models involve providing guidelines to simplify the application of RAMs by the designers. The model has been validated for its practicality and usefulness during a workshop by experienced designers. DOI: 10.3763/aedm.2008.0100 Published in the Journal AEDM - Volume 5, Number 4, 2009 , pp. 179-192(14

  2. Radiographer-led breast boost localisation – A service evaluation study

    International Nuclear Information System (INIS)

    Smith, S.; Comins, C.

    2015-01-01

    A radiation boost to the tumour bed as part of breast conserving therapy reduces the rate of local recurrence. Radiographer-led planning for tangential field radiotherapy has been the practice at our centre since 2007. The transition from conventional simulation to computed tomography (CT) and virtual simulation enhanced the radiographer's role in the breast planning process. Electron boost mark ups continued to be marked up freehand by doctors using available imaging to determine tumour bed. The paper reports on a service evaluation undertaken to establish a change in practice for electron breast boosts to be simulated using the virtual simulator by suitably trained radiographers. The retrospective simulation of ten patients confirmed the consistency of radiographer tumour bed localisation, followed by the prospective simulation of ten patients' boost fields. The introduction of a radiographer-led planning breast boost service has given greater autonomy and job satisfaction to individuals as well as resulting in a cost effective use of available resources. - Highlights: • A service evaluation study was undertaken to train a radiographer to perform breast boost planning. • Retrospective breast boost planning established proposed technique was workable. • Prospective planning by radiographer proved their competence. • Introduction of new technique provided job satisfaction and service improvement

  3. Inter- and intrareader variability in the interpretation of two radiographic classification systems for juvenile rheumatoid arthritis

    International Nuclear Information System (INIS)

    Doria, Andrea S.; Castro, Claudio C. de; Sernik, Renato A.; Vitule, Luis F.; Arantes, Paula R.; Lucato, Leandro; Germano, Marco A.N.; Cerri, Giovanni G.; Kiss, Maria Helena B.; Silva, Carlos H.M.; Zerbini, Cristiano A.F.

    2003-01-01

    To evaluate the inter- and intrareader variability for interpretation of a modified Larsen's radiographic classification system for juvenile rheumatoid arthritis (JRA) focused on osteochondral lesions and a conventional Larsen's classification system, compared to a reference MR scoring system of corresponding images. Seventy-five radiographs of 60 children with JRA, performed within a short interval of time from the MR examinations, were independently evaluated by three experienced radiologists, three diagnostic imaging residents and three rheumatologists, in two separate sessions, according to the two different classification methods, blinded to the corresponding MR images. The inter- and intrareader concordance rates between the two radiographic classification systems and the MR-related radiographs were respectively poor and poor/moderate. The interobserver range of weighted kappa values for the conventional and the modified Larsen's system respectively was 0.25-0.37 vs 0.19-0.39 for radiologists, 0.25-0.37 vs 0.18-0.30 for residents and 0.19-0.51 vs 0.17-0.29 for rheumatologists. The intrareader rate ranged from 0.17-0.55 for radiologists, 0.2-0.56 for residents, and 0.14-0.59 for rheumatologists. Although the proposal of a new radiographic classification system for JRA focused on osteochondral abnormalities sounds promising, the low inter- and intrareader concordance rates with an MR-related radiographic system makes the clinical applicability of such a radiographic system less suitable. (orig.)

  4. AN EFFECTIVE RISK-PREVENTIVE MODEL PROPOSAL FOR OCCUPATIONAL ACCIDENTS AT SHIPYARDS

    Directory of Open Access Journals (Sweden)

    Ozge Acuner

    2016-03-01

    Full Text Available According to the statistics of occupational accidents, it is observed that the number of accidents occurred in shipbuilding industry is high and the rate of deaths and serious injuries among these accidents is higher than in other industries. However, the number of the studies to prevent these accidents in both industrial and scientific practices is considerably low. Therefore, the objective of this study is to develop an efficient risk preventive model in accordance with occupational health and safety regulations for industrial organizations. The approach proposed in this study differs from those described in the literature, because it is based on fuzzy set theory in order to cope with uncertainties on probability and severity definitions in terms of occupational health and safety. Furthermore, in this paper, risk severity is considered in terms of harm to worker, harm to environment, and harm to hardware, whereas in the literature, risk severity is generally considered solely in terms of only harm to worker. Then, risk magnitude is obtained by utilizing fuzzy inference system. The proposed approach is applied to a shipyard located in the Marmara Region in order to illustrate the applicability of the model.

  5. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  6. Proposed retention model for human inhalation exposure to 241AmO2

    International Nuclear Information System (INIS)

    Mewhinney, J.A.; Griffith, W.C.; Muggenburg, B.A.

    1980-01-01

    A dosimetry model based on a four-year study in Beagle dogs was developed to predict patterns of absorbed radiation doses for people exposed by inhalation to 241 AmO 2 . Following a single inhalation exposure to one of three sizes of monodisperse or a polydisperse aerosol of 241 AmO 2 , pairs of dogs were sacrificed at 8, 32, 64 and 256 days, and 2 and 4 years. For about 80% of the initial lung burden, the retention halftimes were 11, 18, 26 and 27 days for the 0.75, 1.5 and 3.0 μm aerodynamic diameter and the 1.8 μm activity median aerodynamic diameter aerosols, respectively. For the remaining 20% of the initial lung burden, the retention halftimes were between 200 to 300 days with no apparent particle size influence. Additional 241 Am metabolic studies reported in the literature using inhalation exposure or injection of the citrate complex were synthesized in the model as were eleven reported cases of human inhalation exposure. This model is compared to the ICRP II and TGLD lung models, both developed by analogy to Pu metabolism. The proposed model differs from these latter models in two important areas: (a) lung retention of 241 AmO 2 could not be adapted to the classifications used in these models, and (b) the fractional translocation from lung to other organs is 2 to 8 times larger. These factors considerably alter the predicted radiation dose distribution among organs and lead to the conclusion that derived radiation protection standards for 241 AmO 2 inhalation exposure should be modified. (author)

  7. On the scale similarity in large eddy simulation. A proposal of a new model

    International Nuclear Information System (INIS)

    Pasero, E.; Cannata, G.; Gallerano, F.

    2004-01-01

    validity of the proposed model was tested through channel flow simulation with friction-velocity-based Reynolds numbers ranging from 180 to 2340. (author)

  8. Information Systems Success In Public Administration: Proposal For An Exploratory Model

    Directory of Open Access Journals (Sweden)

    Deyvison de Lima Oliveira

    2015-12-01

    Full Text Available Investments in Information Systems (IS have been significantly increasing and hence the relevance of the studies on the IS success is persistent. Delone and Mclean (2003 developed an IS successful model which is a benchmark for researches in the area, however, in the perspective of the public sector, studies are still rare. In this research it was sought to propose an exploratory model of successful IS in public administration, from the identification of each construct items of the Delone and McLean (2003 original model, through multiple case studies in three Municipalities and a Town Hall of the Southern Cone of Rondônia state, in Brazil. Based on the empirical research, it was found that the IS success factors in municipal public administration are close to those factors indicated in the reviewed literature, however, showing some particularities of the public sector. A model of successful factors and items of IS, from the confrontation between literature and empirical data, is presented in the end of this work.

  9. Gamma radiographic exposure time indicator

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1979-01-01

    In industrial radiography, with the proper selection of source and film, the radiographic quality depends very much on the exposure time, which in turn depends upon the source strength and the source to film distance. Conventional methods to arrive at correct exposure time involve time consuming calculations and in these methods the knowledge of the above mentioned parameters is imperative. An instrument to determine the required exposure time has been developed which indicates exposure times in about 30 secs. This covers two commonly used gamma radiography sources, viz., 192 Ir and 60 Co and six commonly used radiography films of different speeds. Knowledge of source strength and source to film distance is not required with the use of this instrument. With a knowledge of the total exposure required by the film to give the required sensitivity and by the measurement of radiation level at the film location, the correct exposure time is determined. The radiation level is measured by placing a GM counter behind the radiographic specimen at the film location. To match the responses of the film and the GM counter, the counter is incorporated in a suitably designed probe. In this instruments, an integrator to integrate the GM-pulses and a constant current integrator (timer) are started simultaneously. The voltage at the GM-pulse integrator is compared with a preselected voltage, (selected on the basis of film type, source, source strength and order of object thickness) by a comparator. The comparator is so adjusted that when the GM-pulse integrator voltage exceeds the preselected voltage, it switches its state and stops the integration of constant current. The constant current integrator output which is proportional to the time taken for the GM-pulse integrator to reach the preselected voltage, is read on a meter graduated in terms of exposure time. The instrument can measure exposure times from 5 minutes to 10 hours read in two ranges, the range-changing being automatic

  10. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  11. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  12. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  13. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  14. High dose teriparatide (rPTH1-34) therapy increases callus volume and enhances radiographic healing at 8-weeks in a massive canine femoral allograft model.

    Science.gov (United States)

    Nishitani, Kohei; Mietus, Zachary; Beck, Christopher A; Ito, Hiromu; Matsuda, Shuichi; Awad, Hani A; Ehrhart, Nicole; Schwarz, Edward M

    2017-01-01

    Small animal studies have demonstrated significant high-dose recombinant parathyroid hormone1-34 (rPTH1-34) effects on intercalary allograft healing. Towards a human adjuvant therapy to decrease non-unions, we evaluated rPTH1-34 safety and efficacy in a clinically relevant canine femoral allograft model. Adult female mongrel hounds (n = 20) received a 5cm mid-diaphyseal osteotomy reconstructed with a plated allograft, and were randomized to: 1) Placebo (n = 5; daily saline), 2) Continuous rPTH1-34 (n = 7; 5 μg/kg/day s.c. from day 1-55 post-op), or 3) Delayed rPTH1-34 (n = 8; 5 μg/kg/day s.c. from day 14-28 post-op). Safety was assessed by physical behavior and blood calcium monitoring. Cone beam CT (CB-CT) was performed on days 14, 28 and 56 post-op to assess 2D cortical healing, 3D bone volume, and Union Ratio. Biomechanical testing and dynamic histomorphometry were also performed. The high drug dose was poorly tolerated, as most dogs receiving rPTH1-34 had to be given intravenous saline, and one dog died from hypercalcemia. Continuous rPTH1-34 significantly increased 2D healing and callus volumes at 4-weeks versus Placebo, and sustained the significant increase in cortical union at 8-week (p<0.05). These rPTH1-34 effects were confirmed by histomorphometry, revealing significant increases in mineral apposition rates (MAR) on host bone and graft-host junctions (p<0.05). Delayed rPTH1-34 significantly increased callus volume and MAR at 8 weeks (p<0.05). Although no biomechanical differences were observed, as expected for early healing, the results demonstrated that 2D RUST scoring significantly correlated with torsional biomechanics (p<0.01). In conclusion, 8-weeks of intermittent high-dose rPTH1-34 treatment significantly increases callus formation and accelerates bony union of intercalary massive allografts in a clinically relevant canine model, but with serious side-effects from hypercalcemia.

  15. High dose teriparatide (rPTH1-34 therapy increases callus volume and enhances radiographic healing at 8-weeks in a massive canine femoral allograft model.

    Directory of Open Access Journals (Sweden)

    Kohei Nishitani

    Full Text Available Small animal studies have demonstrated significant high-dose recombinant parathyroid hormone1-34 (rPTH1-34 effects on intercalary allograft healing. Towards a human adjuvant therapy to decrease non-unions, we evaluated rPTH1-34 safety and efficacy in a clinically relevant canine femoral allograft model. Adult female mongrel hounds (n = 20 received a 5cm mid-diaphyseal osteotomy reconstructed with a plated allograft, and were randomized to: 1 Placebo (n = 5; daily saline, 2 Continuous rPTH1-34 (n = 7; 5 μg/kg/day s.c. from day 1-55 post-op, or 3 Delayed rPTH1-34 (n = 8; 5 μg/kg/day s.c. from day 14-28 post-op. Safety was assessed by physical behavior and blood calcium monitoring. Cone beam CT (CB-CT was performed on days 14, 28 and 56 post-op to assess 2D cortical healing, 3D bone volume, and Union Ratio. Biomechanical testing and dynamic histomorphometry were also performed. The high drug dose was poorly tolerated, as most dogs receiving rPTH1-34 had to be given intravenous saline, and one dog died from hypercalcemia. Continuous rPTH1-34 significantly increased 2D healing and callus volumes at 4-weeks versus Placebo, and sustained the significant increase in cortical union at 8-week (p<0.05. These rPTH1-34 effects were confirmed by histomorphometry, revealing significant increases in mineral apposition rates (MAR on host bone and graft-host junctions (p<0.05. Delayed rPTH1-34 significantly increased callus volume and MAR at 8 weeks (p<0.05. Although no biomechanical differences were observed, as expected for early healing, the results demonstrated that 2D RUST scoring significantly correlated with torsional biomechanics (p<0.01. In conclusion, 8-weeks of intermittent high-dose rPTH1-34 treatment significantly increases callus formation and accelerates bony union of intercalary massive allografts in a clinically relevant canine model, but with serious side-effects from hypercalcemia.

  16. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  17. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  18. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  19. Radiographic observation for tuberculous spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Se; Jung, Marn Kyoon; Kim, Byung Soo [College of Medicine, Busan National University, Busan (Korea, Republic of)

    1974-04-15

    Radiographic observation of 152 cases of tuberculous spondylitis selected from total 194 cases of tuberculous arthritis during the past 6 years and 8 months, was carried out to study. 1. The youngest one was 15 months old male infant of active tuberculous spondylitis. The active tuberculous spondylitis under 10 years of age were 50 percent (28 cases). 2. The ratio of male to female was 1.5:1 3. The most common site of involvement was the lumbar spine which was 44.1 percent of the total tuberculous spondylitis. The next were thoracic spine (33.6%), and thoraco-lumber spine (13.1%). 4. The most common roentgenographic findings are bony destructions of the vertebral bodies which were 97.4 percent. The next were joint space narrowing (93.4%), osteoporosis (79.6%), kyphosis (34.2%), fusion deformity of the vertebral body (25.7%), and cold abscess shadow (16.4%). 5. The most of patients (88.8%) had or have been pulmonary tuberculous lesions. 6. In annual incidence, the number of patients were not changed greatly.

  20. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V.

    1995-01-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  1. Socio-economic vulnerability to natural hazards - proposal for an indicator-based model

    Science.gov (United States)

    Eidsvig, U.; McLean, A.; Vangelsten, B. V.; Kalsnes, B.; Ciurean, R. L.; Argyroudis, S.; Winter, M.; Corominas, J.; Mavrouli, O. C.; Fotopoulou, S.; Pitilakis, K.; Baills, A.; Malet, J. P.

    2012-04-01

    Vulnerability assessment, with respect to natural hazards, is a complex process that must consider multiple dimensions of vulnerability, including both physical and social factors. Physical vulnerability refers to conditions of physical assets, and may be modeled by the intensity and magnitude of the hazard, the degree of physical protection provided by the natural and built environment, and the physical robustness of the exposed elements. Social vulnerability refers to the underlying factors leading to the inability of people, organizations, and societies to withstand impacts from the natural hazards. Social vulnerability models can be used in combination with physical vulnerability models to estimate both direct losses, i.e. losses that occur during and immediately after the impact, as well as indirect losses, i.e. long-term effects of the event. Direct impact of a landslide typically includes casualties and damages to buildings and infrastructure while indirect losses may e.g. include business closures or limitations in public services. The direct losses are often assessed using physical vulnerability indicators (e.g. construction material, height of buildings), while indirect losses are mainly assessed using social indicators (e.g. economical resources, demographic conditions). Within the EC-FP7 SafeLand research project, an indicator-based method was proposed to assess relative socio-economic vulnerability to landslides. The indicators represent the underlying factors which influence a community's ability to prepare for, deal with, and recover from the damage associated with landslides. The proposed model includes indicators representing demographic, economic and social characteristics as well as indicators representing the degree of preparedness and recovery capacity. Although the model focuses primarily on the indirect losses, it could easily be extended to include more physical indicators which account for the direct losses. Each indicator is individually

  2. A new bite block for panoramic radiographs of anterior edentulous patients: A technical report.

    Science.gov (United States)

    Park, Jong-Woong; Symkhampha, Khanthaly; Huh, Kyung-Hoe; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul

    2015-06-01

    Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.

  3. An Algorithm for Data Hiding in Radiographic Images and ePHI/R Application

    Directory of Open Access Journals (Sweden)

    Aqsa Rashid

    2018-01-01

    Full Text Available Telemedicine is the use of Information and Communication Technology (ICT for clinical health care from a distance. The exchange of radiographic images and electronic patient health information/records (ePHI/R for diagnostic purposes has the risk of confidentiality, ownership identity, and authenticity. In this paper, a data hiding technique for ePHI/R is proposed. The color information in the cover image is used for key generation, and stego-images are produced with ideal case. As a result, the whole stego-system is perfectly secure. This method includes the features of watermarking and steganography techniques. The method is applied to radiographic images. For the radiographic images, this method resembles watermarking, which is an ePHI/R data system. Experiments show promising results for the application of this method to radiographic images in ePHI/R for both transmission and storage purpose.

  4. A radiographic study of the mandibular third molar root development in different ethnic groups.

    Science.gov (United States)

    Liversidge, H M; Peariasamy, K; Folayan, M O; Adeniyi, A O; Ngom, P I; Mikami, Y; Shimada, Y; Kuroe, K; Tvete, I F; Kvaal, S I

    2017-12-01

    The nature of differences in the timing of tooth formation between ethnic groups is important when estimating age. To calculate age of transition of the mandibular third (M3) molar tooth stages from archived dental radiographs from sub-Saharan Africa, Malaysia, Japan and two groups from London UK (Whites and Bangladeshi). The number of radiographs was 4555 (2028 males, 2527 females) with an age range 10-25 years. The left M3 was staged into Moorrees stages. A probit model was fitted to calculate mean ages for transitions between stages for males and females and each ethnic group separately. The estimated age distributions given each M3 stage was calculated. To assess differences in timing of M3 between ethnic groups, three models were proposed: a separate model for each ethnic group, a joint model and a third model combining some aspects across groups. The best model fit was tested using Bayesian and Akaikes information criteria (BIC and AIC) and log likelihood ratio test. Differences in mean ages of M3 root stages were found between ethnic groups, however all groups showed large standard deviation values. The AIC and log likelihood ratio test indicated that a separate model for each ethnic group was best. Small differences were also noted between timing of M3 between males and females, with the exception of the Malaysian group. These findings suggests that features of a reference data set (wide age range and uniform age distribution) and a Bayesian statistical approach are more important than population specific convenience samples to estimate age of an individual using M3. Some group differences were evident in M3 timing, however, this has some impact on the confidence interval of estimated age in females and little impact in males because of the large variation in age.

  5. A Proposed Model for Assessing Organisational Culture Towards Achieving Business Objectives

    Directory of Open Access Journals (Sweden)

    Hafez Salleh

    2011-09-01

    Full Text Available Most of the traditional business performances measures are based on productivity and process criteria, which mainly focus on method of investment appraisal such as payback method, return on investment (ROI, cost-benefits analysis (CBA, net present value (NPV, internal rate of return (IRR. However, the measurement scales of business performance are not limited to those measures. One element that has strong correlation to the business performances is ‘organisational culture’. Many studies proved that one of the significant criteria for achieving desired business objectives is the right organisational culture within workplace. Basically, the measurement of organisational culture is reflecting on two distinct elements: organisational culture and business objectives. In broader perspective, an organisation is considered effective if it meets its business objectives. This paper aims to present and discuss the preliminary culture model to indicate the culture performance within organisational. The model has been developed through literature review, expert opinion and experience which is anticipated of being able to potentially measure the culture capability of organisations across industries to “successfully achieve business objectives”. The model is composed of six progressive stages of maturity that an organisation can achieve its culture performance. For each maturity stage, the model describes a set of characteristics that must be in place for the company to achieve each stage. The validity of the proposed model will be tested by a few case studies. The idea is to provide managers with a qualitative measurement tools to enable them to identify where culture improvements are required within their organisations and to indicate their readiness for achieving business objectives.

  6. Global model of zenith tropospheric delay proposed based on EOF analysis

    Science.gov (United States)

    Sun, Langlang; Chen, Peng; Wei, Erhu; Li, Qinzheng

    2017-07-01

    Tropospheric delay is one of the main error budgets in Global Navigation Satellite System (GNSS) measurements. Many empirical correction models have been developed to compensate this delay, and models which do not require meteorological parameters have received the most attention. This study established a global troposphere zenith total delay (ZTD) model, called Global Empirical Orthogonal Function Troposphere (GEOFT), based on the empirical orthogonal function (EOF, also known as geographically weighted PCAs) analysis method and the Global Geodetic Observing System (GGOS) Atmosphere data from 2012 to 2015. The results showed that ZTD variation could be well represented by the characteristics of the EOF base function Ek and associated coefficients Pk. Here, E1 mainly signifies the equatorial anomaly; E2 represents north-south asymmetry, and E3 and E4 reflects regional variation. Moreover, P1 mainly reflects annual and semiannual variation components; P2 and P3 mainly contains annual variation components, and P4 displays semiannual variation components. We validated the proposed GEOFT model using tropospheric delay data of GGOS ZTD grid data and the tropospheric product of the International GNSS Service (IGS) over the year 2016. The results showed that GEOFT model has high accuracy with bias and RMS of -0.3 and 3.9 cm, respectively, with respect to the GGOS ZTD data, and of -0.8 and 4.1 cm, respectively, with respect to the global IGS tropospheric product. The accuracy of GEOFT demonstrating that the use of the EOF analysis method to characterize ZTD variation is reasonable.

  7. A proposed centralised distribution model for the South African automotive component industry

    Directory of Open Access Journals (Sweden)

    Micheline J. Naude

    2009-12-01

    Full Text Available Purpose: This article explores the possibility of developing a distribution model, similar to the model developed and implemented by the South African pharmaceutical industry, which could be implemented by automotive component manufacturers for supply to independent retailers. Problem Investigated: The South African automotive components distribution chain is extensive with a number of players of varying sizes, from the larger spares distribution groups to a number of independent retailers. Distributing to the smaller independent retailers is costly for the automotive component manufacturers. Methodology: This study is based on a preliminary study of an explorative nature. Interviews were conducted with a senior staff member from a leading automotive component manufacturer in KwaZulu Natal and nine participants at a senior management level at five of their main customers (aftermarket retailers. Findings: The findings from the empirical study suggest that the aftermarket component industry is mature with the role players well established. The distribution chain to the independent retailer is expensive in terms of transaction and distribution costs for the automotive component manufacturer. A proposed centralised distribution model for supply to independent retailers has been developed which should reduce distribution costs for the automotive component manufacturer in terms of (1 the lowest possible freight rate; (2 timely and controlled delivery; and (3 reduced congestion at the customer's receiving dock. Originality: This research is original in that it explores the possibility of implementing a centralised distribution model for independent retailers in the automotive component industry. Furthermore, there is a dearth of published research on the South African automotive component industry particularly addressing distribution issues. Conclusion: The distribution model as suggested is a practical one and should deliver added value to automotive

  8. MODEL REQUEST FOR PROPOSALS TO PROVIDE ENERGY AND OTHER ATTRIBUTES FROM AN OFFSHORE WIND POWER PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Jeremy Firestone; Dawn Kurtz Crompton

    2011-10-22

    This document provides a model RFP for new generation. The 'base' RFP is for a single-source offshore wind RFP. Required modifications are noted should a state or utility seek multi-source bids (e.g., all renewables or all sources). The model is premised on proposals meeting threshold requirements (e.g., a MW range of generating capacity and a range in terms of years), RFP issuer preferences (e.g., likelihood of commercial operation by a date certain, price certainty, and reduction in congestion), and evaluation criteria, along with a series of plans (e.g., site, environmental effects, construction, community outreach, interconnection, etc.). The Model RFP places the most weight on project risk (45%), followed by project economics (35%), and environmental and social considerations (20%). However, if a multi-source RFP is put forward, the sponsor would need to either add per-MWh technology-specific, life-cycle climate (CO2), environmental and health impact costs to bid prices under the 'Project Economics' category or it should increase the weight given to the 'Environmental and Social Considerations' category.

  9. A proposed model for assessing service quality in small machining and industrial maintenance companies

    Directory of Open Access Journals (Sweden)

    Morvam dos Santos Netto

    2014-11-01

    Full Text Available Machining and industrial maintenance services include repair (corrective maintenance of equipments, activities involving the assembly-disassembly of equipments, fault diagnosis, machining operations, forming operations, welding processes, assembly and test of equipments. This article proposes a model for assessing the quality of services provided by small machining and industrial maintenance companies, since there is a gap in the literature regarding this issue and because the importance of small service companies in socio-economic development of the country. The model is an adaptation of the SERVQUAL instrument and the criteria determining the quality of services are designed according to the service cycle of a typical small machining and industrial maintenance company. In this sense, the Moments of Truth have been considered in the preparation of two separate questionnaires. The first questionnaire contains 24 statements that reflect the expectations of customers, and the second one contains 24 statements that measure perceptions of service performance. An additional item was included in each questionnaire to assess, respectively, the overall expectation about the services and the overall company performance. Therefore, it is a model that considers the interfaces of the client/supplier relationship, the peculiarities of the machining and industrial maintenance service sector and the company size.

  10. A data envelopment analysis based model for proposing safety improvements: a FMEA approach

    International Nuclear Information System (INIS)

    Garcia, Pauli A. de A.; Barbosa Junior, Gilberto V.; Melo, P.F. Frutuoso e

    2005-01-01

    When performing a probabilistic safety assessment, one important step is the identification of the critical or weak points of all systems to be considered. By properly ranking these critical points, improvement recommendations may be proposed, in order to reduce the associated risks. Many tools are available for the identification of critical points, like the Failure Mode and Effect Analysis (FMEA) and the Hazard and Operability Studies (HAZOP). Once the failure modes or deviations are identified, indices associated to the occurrence probabilities, detection potential, and the effects severity, are assigned to them, and so the failure modes or deviations ranking is performed. It is common practice to assign risk priority numbers for this purpose. These numbers are obtained by multiplying the three aforementioned indices, which typically vary from 1 to 10 (natural numbers). Here, the greater the index, the worst the situation. In this paper, a data envelopment analysis (DEA) based model is used to identify the most critical failure modes or deviations and, by means of their respective distances to the boundary, to assess the improvement percentage for each index of each failure mode or deviation. Starting from this identification procedure, the decision maker can more efficiently propose improvement actions, like reliability allocation, detection design, protective barriers, etc. (author)

  11. Futility Disputes: A Review of the Literature and Proposed Model for Dispute Navigation Through Trust Building.

    Science.gov (United States)

    Leland, Brian D; Torke, Alexia M; Wocial, Lucia D; Helft, Paul R

    2017-10-01

    Futility disputes in the intensive care unit setting have received significant attention in the literature over the past several years. Although the idea of improving communication in an attempt to resolve these challenging situations has been regularly discussed, the concept and role of trust building as the means by which communication improves and disputes are best navigated is largely absent. We take this opportunity to review the current literature on futility disputes and argue the important role of broken trust in these encounters, highlighting current evidence establishing the necessity and utility of trust in both medical decision-making and effective communication. Finally, we propose a futility dispute navigation model built upon improved communication through trust building.

  12. The role of tourism public-private partnerships in regional development: a conceptual model proposal

    Directory of Open Access Journals (Sweden)

    Mário Franco

    Full Text Available Tourism is characterized as being a sector that stands out as one of the business activities with the greatest potential for worldwide expansion, and as an engine for economic growth. If at the national level, the appeal of tourism is significant, on the local level this sector presents itself as an essential tool in regional development, as a means to avoid regional desertification and stagnation, stimulating the potential of more undeveloped regions. In such a competitive sector as tourism, companies should develop synergies and achieve competitive advantage. In this context, public-private partnerships play an important role in regional development. The aim of this paper is to present a theoretical context that combines different concepts and elements to explain and understand the public-private partnership phenomenon in tourism. A conceptual model of the role of public-private partnerships will be proposed in order to contribute to successful regional development.

  13. Cognitive processes and neural basis of language switching: proposal of a new model.

    Science.gov (United States)

    Moritz-Gasser, Sylvie; Duffau, Hugues

    2009-12-09

    Although studies on bilingualism are abundant, cognitive processes and neural foundations of language switching received less attention. The aim of our study is to provide new insights to this still open question: do dedicated region(s) for language switching exist or is this function underlain by a distributed circuit of interconnected brain areas, part of a more general cognitive system? On the basis of recent behavioral, neuroimaging, and brain stimulation studies, we propose an original 'hodological' model of language switching. This process might be subserved by a large-scale cortico-subcortical network, with an executive system (prefrontal cortex, anterior cingulum, caudate nucleus) controlling a more dedicated language subcircuit, which involves postero-temporal areas, supramarginal and angular gyri, Broca's area, and the superior longitudinal fasciculus.

  14. Computational Approaches to Modeling Artificial Emotion -– An overview of the Proposed Solutions

    Directory of Open Access Journals (Sweden)

    Zdzislaw eKOWALCZUK

    2016-04-01

    Full Text Available Cybernetic approach to modeling artificial emotion through the use of different theories of psychology is considered in this paper, presenting a review of twelve proposed solutions: ActAffAct, FLAME, EMA, ParleE, FearNot!, FAtiMA, WASABI, Cathexis, KARO, MAMID, FCM, and xEmotion. The main motivation for this study is founded on the hypothesis that emotions can play a definite utility role of scheduling variables in the construction of intelligent autonomous systems, agents and mobile robots. In this review we also include an innovative and panoptical, comprehensive system, referred to as the Intelligent System of Decision-making (ISD, which has been employed in practical applications of various autonomous units, and which applies as its part the xEmotion, taking into consideration the personal aspects of emotions, affects (short term emotions and mood (principally, long term emotions.

  15. A proposed simulation optimization model framework for emergency department problems in public hospital

    Science.gov (United States)

    Ibrahim, Ireen Munira; Liong, Choong-Yeun; Bakar, Sakhinah Abu; Ahmad, Norazura; Najmuddin, Ahmad Farid

    2015-12-01

    The Emergency Department (ED) is a very complex system with limited resources to support increase in demand. ED services are considered as good quality if they can meet the patient's expectation. Long waiting times and length of stay is always the main problem faced by the management. The management of ED should give greater emphasis on their capacity of resources in order to increase the quality of services, which conforms to patient satisfaction. This paper is a review of work in progress of a study being conducted in a government hospital in Selangor, Malaysia. This paper proposed a simulation optimization model framework which is used to study ED operations and problems as well as to find an optimal solution to the problems. The integration of simulation and optimization is hoped can assist management in decision making process regarding their resource capacity planning in order to improve current and future ED operations.

  16. An integrated ethical approach to bioethical decision-making: A proposed model for ministers

    Directory of Open Access Journals (Sweden)

    Magdalena C. de Lange

    2012-10-01

    Full Text Available This article outlined a model for guidance in ‘doing’ bioethics in a Reformed context. The proposed model suggested that in order to arrive at responsible ethical decisions, one must refer to both contextual elements and theory. The theoretical grounding for this model was based on the integration of a deontological and virtue ethics approach, arguing that virtue enables persons to know and desire the right moral ends and motivates them to carry out appropriate action toward achieving these ends. An integrative model opens up the possibility whereby bioethics as a systematic tool provides the individual decision-maker with the critical-reflective skills and justification for the ultimate choice that is lacking in the general decision-making processes. This could lead to clearer thinking and increased confidence in the justification of decisions within the Reformed tradition. The proposed hermeneutical perspective on ethical decision-making represents a shift in views about the nature of knowledge and the process of how we come to know. The key to this hermeneutical approach is to acknowledge the dialectic between the universal and the subjectivity of human relations. Working in specific religious communities, one needs to take cognisance of the fact that knowledge is situated in the context of human relationships in which the interpreter participates when articulating the meaning of bioethical experiences. Another aspect that is anticipated lies in the realisation that people struggling with bioethical dilemmas should not be viewed as isolated individuals, but as members of a broader faith community. ‘n Geïntegreerde etiese benadering tot bioetiese besluitneming: Voorgestelde model vir predikante. Hierdie artikel het ‘n model geskets wat moontlike riglyne aantoon vir die  beoefening  van  bioetiek  binne  ‘n  Gereformeerde  konteks.  Die  voorgestelde  model argumenteer dat verwysing na beide kontekstuele elemente en teorie

  17. 3-Dimensional Flow Modeling of a Proposed Hanford Waste Treatment Plant Ion-Exchange Column Design

    International Nuclear Information System (INIS)

    ALEMAN, SEBASTIAN

    2002-01-01

    Historically, it has been assumed that the inlet and outlet low activity waste plenums would be designed such that a nearly uniform velocity profile would be maintained at every axial cross-section (i.e., providing nearly 100 percent use of the resin bed). With this proposed design, we see a LAW outlet distributor that results in significant non-axial velocity gradients in the bottom regions of the bed with the potential to reduce the effectiveness'' of the overall resin bed. The magnitude of this efficiency reduction depends upon how far up-gradient of the LAW outlet these non-axial velocities persist and to what extent a ''dead-zone'' is established beneath the LAW outlet. This can impact loading and elution performance of the ion-exchange facility. Currently, no experimental studies are planned. The primary objective of this work was, through modeling, to assess the fluid dynamic impact on ''effective'' resin volume of the full-scale column based on its normal operation using a recently proposed LAW outlet distributor. The analysis effort was limited to 3-D flow only analyses (i.e., no follow on transport analyses) with 3-D particle tracking to approximate the impact that a nonaxial velocity profile would have on bed ''effectiveness''. Additional analyses were performed to estimate under nominal operating conditions the thermal temperature rise across a loaded resin bed and within its particles. Hydrogen bubble formation is not considered in the heat transfer analysis or in the determination of minimum flowrate. All modeling objectives were met

  18. Automating Construction of Machine Learning Models With Clinical Big Data: Proposal Rationale and Methods.

    Science.gov (United States)

    Luo, Gang; Stone, Bryan L; Johnson, Michael D; Tarczy-Hornoch, Peter; Wilcox, Adam B; Mooney, Sean D; Sheng, Xiaoming; Haug, Peter J; Nkoy, Flory L

    2017-08-29

    To improve health outcomes and cut health care costs, we often need to conduct prediction/classification using large clinical datasets (aka, clinical big data), for example, to identify high-risk patients for preventive interventions. Machine learning has been proposed as a key technology for doing this. Machine learning has won most data science competitions and could support many clinical activities, yet only 15% of hospitals use it for even limited purposes. Despite familiarity with data, health care researchers often lack machine learning expertise to directly use clinical big data, creating a hurdle in realizing value from their data. Health care researchers can work with data scientists with deep machine learning knowledge, but it takes time and effort for both parties to communicate effectively. Facing a shortage in the United States of data scientists and hiring competition from companies with deep pockets, health care systems have difficulty recruiting data scientists. Building and generalizing a machine learning model often requires hundreds to thousands of manual iterations by data scientists to select the following: (1) hyper-parameter values and complex algorithms that greatly affect model accuracy and (2) operators and periods for temporally aggregating clinical attributes (eg, whether a patient's weight kept rising in the past year). This process becomes infeasible with limited budgets. This study's goal is to enable health care researchers to directly use clinical big data, make machine learning feasible with limited budgets and data scientist resources, and realize value from data. This study will allow us to achieve the following: (1) finish developing the new software, Automated Machine Learning (Auto-ML), to automate model selection for machine learning with clinical big data and validate Auto-ML on seven benchmark modeling problems of clinical importance; (2) apply Auto-ML and novel methodology to two new modeling problems crucial for care

  19. [Acute kidney injury after pediatric cardiac surgery: risk factors and outcomes. Proposal for a predictive model].

    Science.gov (United States)

    Cardoso, Bárbara; Laranjo, Sérgio; Gomes, Inês; Freitas, Isabel; Trigo, Conceição; Fragata, Isabel; Fragata, José; Pinto, Fátima

    2016-02-01

    To characterize the epidemiology and risk factors for acute kidney injury (AKI) after pediatric cardiac surgery in our center, to determine its association with poor short-term outcomes, and to develop a logistic regression model that will predict the risk of AKI for the study population. This single-center, retrospective study included consecutive pediatric patients with congenital heart disease who underwent cardiac surgery between January 2010 and December 2012. Exclusion criteria were a history of renal disease, dialysis or renal transplantation. Of the 325 patients included, median age three years (1 day-18 years), AKI occurred in 40 (12.3%) on the first postoperative day. Overall mortality was 13 (4%), nine of whom were in the AKI group. AKI was significantly associated with length of intensive care unit stay, length of mechanical ventilation and in-hospital death (p<0.01). Patients' age and postoperative serum creatinine, blood urea nitrogen and lactate levels were included in the logistic regression model as predictor variables. The model accurately predicted AKI in this population, with a maximum combined sensitivity of 82.1% and specificity of 75.4%. AKI is common and is associated with poor short-term outcomes in this setting. Younger age and higher postoperative serum creatinine, blood urea nitrogen and lactate levels were powerful predictors of renal injury in this population. The proposed model could be a useful tool for risk stratification of these patients. Copyright © 2015 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  20. B220 analysis with the local lymph node assay: proposal for a more flexible prediction model.

    Science.gov (United States)

    Betts, Catherine J; Dearman, Rebecca J; Kimber, Ian; Ryan, Cindy A; Gerberick, G Frank; Lalko, Jon; Api, Anne Marie

    2007-01-01

    The mouse local lymph node assay (LLNA) has been developed and validated for the identification of chemicals that have the potential to induce skin sensitisation. In common with other predictive test methods the accuracy of the LLNA is not absolute and experience has revealed that a few chemicals, including for instance a minority of skin irritants, may elicit false-positive reactions in the assay. To improve further the performance of the LLNA, and to eliminate or reduce false-positives, there has been interest in an adjunct method in which the ability of chemicals to cause increases in the frequency of B220(+) lymphocytes in skin-draining lymph nodes is measured. Previous studies suggest that the use of B220 analyses aligned with the standard LLNA may serve to distinguish further between contact allergens and skin irritants. In the original predictive model, chemicals were regarded as being skin sensitisers if they were able to induce a 1.25-fold or greater increase in the percentage of B220(+) cells within lymph nodes compared with concurrent vehicle controls. Although this first prediction model has proven useful, in the light of more recent experience, and specifically as a consequence of some variability observed in the frequency of B220(+) lymphocytes in nodes taken from vehicle control-treated animals, it is timely now to reconsider and refine the model. As a result a new prediction model is proposed in which reliance on the use of absolute thresholds is reduced, and in which small changes in control values can be better accommodated. (c) 2007 John Wiley & Sons, Ltd.

  1. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  2. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  3. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  4. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  5. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  6. A comparative analysis of emotional intelligence in the UK and Australian radiographer workforce

    International Nuclear Information System (INIS)

    Mackay, S.J.; Baker, R.; Collier, D.; Lewis, S.

    2013-01-01

    Emotional intelligence (EI) in the UK radiographer workforce has been benchmarked using the trait emotional intelligence model and the profile of the profession in the UK has begun to emerge. There are cultural differences between countries that have been shown to have an effect on EI, therefore this paper aims to benchmark the Global and four factor scores of Trait EI in the Australian radiographer population; to explore any differences within the two main professional groupings, diagnostic and therapeutic radiographers, and to compare the Australian radiographer workforce scores with those of the UK previously published. The published and validated trait EI questionnaire of Petrides was used as the survey tool for the Global EI and the four factors of Well-being, Emotionality, Self-control and Sociability. There was only one difference found in the five factors studied between the UK and Australian radiographer workforce, that of Well-being (p ≤ 0.01). No differences emerged between the diagnostic and therapy disciplines nor was a relationship found between EI and the Australian leadership in contrast to the UK workforce findings. Differences were found in the demographic profiles of the two countries and the implications of the above findings are discussed. This paper has benchmarked the EI of the Australian workforce and found a difference in well-being between the UK and Australian radiographer workforce. The Australian diagnostic and therapy disciplines were no different in their EI profiles. No relationship was found between EI and leadership in the Australian radiographer workforce

  7. Nuclear Power Plant Life Management - Challenges and Proposal for a Unified Model Integrating Safety and Economics

    International Nuclear Information System (INIS)

    Contri, Paolo; Elsing, Bernhard

    2011-01-01

    In recent years many electric utilities and nuclear power plants adopted policies for improved coordination of both safety and non-safety programs, called plant life management (PLIM), also in view on plant life extension programs, but mainly for an optimisation of operating costs. The implementation of PLIM programs has followed many different approaches, being intrinsically dependent on the national regulatory framework and technical traditions. In Countries with some experience, the PLIM program proved very convenient, especially when coupled with Maintenance, Surveillance an Inspection (MS and I) optimization: average savings are reported in the range of 20-30% of total (maintenance) costs. A unified European model for PLIM was developed at the JRC-Institute for Energy with the support of a network of stakeholders (SENUF), and validated at some EU nuclear plants. This paper provides a summary of the model features, the result of its validation at some plants and summarises the perceived scientific/technological challenges on which JRC proposes to focus, based upon its competencies and skills, having in mind both the European and world-wide context and its potential evolution. (author)

  8. A proposal of ecologic taxes based on thermo-economic performance of heat engine models

    International Nuclear Information System (INIS)

    Barranco-Jimenez, M. A.; Ramos-Gayosso, I.; Rosales, M. A.; Angulo-Brown, F.

    2009-01-01

    Within the context of Finite-Time Thermodynamics (FTT) a simplified thermal power plant model (the so-called Novikov engine) is analyzed under economical criteria by means of the concepts of profit function and the costs involved in the performance of the power plant. In this study, two different heat transfer laws are used, the so called Newton's law of cooling and the Dulong-Petit's law of cooling. Two FTT optimization criteria for the performance analysis are used: the maximum power regime (MP) and the so-called ecological criterion. This last criterion leads the engine model towards a mode of performance that appreciably diminishes the engine's wasted energy. In this work, it is shown that the energy-unit price produced under maximum power conditions is cheaper than that produced under maximum ecological (ME) conditions. This was accomplished by using a typical definition of profits function stemming from economics. The MP-regime produces considerably more wasted energy toward the environment, thus the MP energy-unit price is subsidized by nature. Due to this fact, an ecological tax is proposed, which could be a certain function of the price difference between the MP and ME modes of power production. (author)

  9. Proposal of a model for sales and operations planning (S&OP maturity evaluation

    Directory of Open Access Journals (Sweden)

    Carolina Belotti Pedroso

    2017-11-01

    Full Text Available Abstract A successful S&OP implementation can bring many benefits to organizations, and after its implementation, the S&OP process can evolve and reach higher levels of maturity. Considering that, only through a measurement system, goals and benefits can be achieved, thus, it is essential to assess S&OP maturity level. Many papers on literature adopt a quantitative perspective on S&OP, but just few of them deal with uncertainty present in S&OP decision-making, such as maturity model assessment process that carries subjectivity and uncertainty. Thus, this study proposes a decision making model based on fuzzy theory to evaluate and to categorize S&OP maturity levels and to suggest strategies to increase S&OP maturity. A pilot application was conducted in two manufacturing organizations that have implemented the S&OP process. The results, according to the performance presented, suggest different actions must be taken in terms of ensuring enablers to S&OP implementation.

  10. A Proposal of Ecologic Taxes Based on Thermo-Economic Performance of Heat Engine Models

    Directory of Open Access Journals (Sweden)

    Fernando Angulo-Brown

    2009-11-01

    Full Text Available Within the context of Finite-Time Thermodynamics (FTT a simplified thermal power plant model (the so-called Novikov engine is analyzed under economical criteria by means of the concepts of profit function and the costs involved in the performance of the power plant. In this study, two different heat transfer laws are used, the so called Newton’s law of cooling and the Dulong-Petit’s law of cooling. Two FTT optimization criteria for the performance analysis are used: the maximum power regime (MP and the so-called ecological criterion. This last criterion leads the engine model towards a mode of performance that appreciably diminishes the engine’s wasted energy. In this work, it is shown that the energy-unit price produced under maximum power conditions is cheaper than that produced under maximum ecological (ME conditions. This was accomplished by using a typical definition of profits function stemming from economics. The MP-regime produces considerably more wasted energy toward the environment, thus the MP energy-unit price is subsidized by nature. Due to this fact, an ecological tax is proposed, which could be a certain function of the price difference between the MP and ME modes of power production.

  11. Competency-Based University Undergraduate Teaching Management: Proposal for a Conceptual Model

    Directory of Open Access Journals (Sweden)

    Rodolfo Schmal

    2005-12-01

    Full Text Available The human resources societies and their organizations can count on are more and more relevant. In that sense, a major challenge faced by universities is to give students the appropriate background to be professionals with the profile the current scenario requires. This article focuses the management of university careers. Historically, many careers have emphasized knowledge, especially abstract knowledge. Today, the trend is to address aspects that reach beyond cognition, and focus the attention in effective competencies that include procedures and attitudes. Such approach allows the opportunity of defining a holistic management of careers, reaching beyond the sheer teaching of disciplines. Concurrently, the availability of information methods and tools will contribute for the definition and implementation of a design process that can work with explicit criteria and transformations. The article proposes a conceptual model to represent the objects, and their attributes and associations that are considered of interest for the management of university teaching under a competency focus. A second stage should implement such model through the construction of an information system that supports the management of corresponding careers.

  12. A proposed model of factors influencing hydrogen fuel cell vehicle acceptance

    Science.gov (United States)

    Imanina, N. H. Noor; Kwe Lu, Tan; Fadhilah, A. R.

    2016-03-01

    Issues such as environmental problem and energy insecurity keep worsening as a result of energy use from household to huge industries including automotive industry. Recently, a new type of zero emission vehicle, hydrogen fuel cell vehicle (HFCV) has received attention. Although there are argues on the feasibility of hydrogen as the future fuel, there is another important issue, which is the acceptance of HFCV. The study of technology acceptance in the early stage is a vital key for a successful introduction and penetration of a technology. This paper proposes a model of factors influencing green vehicle acceptance, specifically HFCV. This model is built base on two technology acceptance theories and other empirical studies of vehicle acceptance. It aims to provide a base for finding the key factors influencing new sustainable energy fuelled vehicle, HFCV acceptance which is achieved by explaining intention to accept HFCV. Intention is influenced by attitude, subjective norm and perceived behavioural control from Theory of Planned Behaviour and personal norm from Norm Activation Theory. In the framework, attitude is influenced by perceptions of benefits and risks, and social trust. Perceived behavioural control is influenced by government interventions. Personal norm is influenced by outcome efficacy and problem awareness.

  13. A proposal of ecologic taxes based on thermo-economic performance of heat engine models

    Energy Technology Data Exchange (ETDEWEB)

    Barranco-Jimenez, M. A. [Departamento de Ciencias Basicas, Escuela Superior de Computo del IPN, Av. Miguel Bernal Esq. Juan de Dios Batiz U.P. Zacatenco CP 07738, D.F. (Mexico); Ramos-Gayosso, I. [Unidad de Administracion de Riesgos, Banco de Mexico, 5 de Mayo, Centro, D.F. (Mexico); Rosales, M. A. [Departamento de Fisica y Matematicas, Universidad de las Americas, Puebla Exhacienda Sta. Catarina Martir, Cholula 72820, Puebla (Mexico); Angulo-Brown, F. [Departamento de Fisica, Escuela Superior de Fisica y Matematicas del IPN, Edif. 9 U.P. Zacatenco CP 07738, D.F. (Mexico)

    2009-07-01

    Within the context of Finite-Time Thermodynamics (FTT) a simplified thermal power plant model (the so-called Novikov engine) is analyzed under economical criteria by means of the concepts of profit function and the costs involved in the performance of the power plant. In this study, two different heat transfer laws are used, the so called Newton's law of cooling and the Dulong-Petit's law of cooling. Two FTT optimization criteria for the performance analysis are used: the maximum power regime (MP) and the so-called ecological criterion. This last criterion leads the engine model towards a mode of performance that appreciably diminishes the engine's wasted energy. In this work, it is shown that the energy-unit price produced under maximum power conditions is cheaper than that produced under maximum ecological (ME) conditions. This was accomplished by using a typical definition of profits function stemming from economics. The MP-regime produces considerably more wasted energy toward the environment, thus the MP energy-unit price is subsidized by nature. Due to this fact, an ecological tax is proposed, which could be a certain function of the price difference between the MP and ME modes of power production. (author)

  14. Proposal for a New Model for Highway Records in the Republic of Croatia

    Directory of Open Access Journals (Sweden)

    Rinaldo Paar

    2012-05-01

    Full Text Available Highways are public roads, whose function is to integrate Croatia in the European transport system, link the regions of Croatia and facilitate transit traffic. They are public property for general use, owned by the Republic of Croatia, and they cannot be the subject of acquisition or other proprietary rights of any kind. Today, there are two types of highway record-keeping. The first is conducted by leading companies authorised to manage highways in order to develop a highway database, or create a highway register. The second is conducted by land-management systems; the Cadastre and Land Registry. They are the official public registers for keeping records of land plots, buildings and other structures, and their ownership. Procedures that need to be implemented in the second type of record-keeping often get "stuck" in practice. Based on the problems identified in this model and an analysis of the state of record-keeping, a proposal for a new model for highway records in the Cadastre and Land Registry is given. Keywords: highways; building plot; expropriation; record; Cadastre; Land Registry

  15. Proposal of a stationary model of dispersion diagnoses of pollutants chemically non-reactivate, applied for mobile sources in Bogota

    International Nuclear Information System (INIS)

    Ruiz Murcia, Jose Franklln; Pabon Caicedo, Jose Daniel

    2002-01-01

    The following document presents a semi empirical model to calculate concentrations of monoxide of carbon in surface by mobile sources. This model considers three basic components: meteorology, emissions and atmospheric chemistry. Scientifically, the propose model is sustained en the fact that the quality of the air depends of the weather's conditions and the numbers of source that is emitting

  16. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  17. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  18. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  19. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  20. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  1. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  2. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  3. Circulation Modeling for Proposed Port Facility at Ponce and Guayanilla, Puerto Rico

    National Research Council Canada - National Science Library

    Scheffner, Norman

    2002-01-01

    ... of Ponce and Guayanilla, Puerto Rico. Impacts of the proposed construction were determined by conducting numerical simulations of tidal and storm surge circulation at the project sites using with and without the proposed port facilities...

  4. Incorporating the user perspective into a proposed model for assessing success of SHS implementations

    Directory of Open Access Journals (Sweden)

    Hans Holtorf

    2015-10-01

    Full Text Available Modern energy can contribute to development in multiple ways while approximately 20% of world's populations do not yet have access to electricity. Solar Home Systems (SHSs consists of a PV module, a charge controller and a battery supply in the range of 100 Wh/d in Sunbelt countries. The question addressed in this paper is how SHS users approach success of their systems and how these user's views can be integrated in to an existing model of success. Information was obtained on the user's approach to their SHSs by participatory observation, interviews with users and by self-observation undertaken by the lead author while residing under SHS electricity supply conditions. It was found that success of SHSs from the users' point of view is related to the ability of these systems to reduce the burdens of supplying energy services to homesteads. SHSs can alleviate some energy supply burdens, and they can improve living conditions by enabling communication on multiple levels and by addressing convenience and safety concerns. However, SHSs do not contribute to the energy services which are indispensable for survival, nor to the thermal energy services required and desired in dwellings of Sunbelt countries. The elements of three of the four components of our previously proposed model of success have been verified and found to be appropriate, namely the user's self-set goals, their importance and SHSs' success factors. The locally appropriate, and scientifically satisfactory, measurement of the level of achievement of self-set goals, the fourth component of our model of success, remains an interesting area for future research.

  5. Proposed best modeling practices for assessing the effects of ecosystem restoration on fish

    Science.gov (United States)

    Rose, Kenneth A; Sable, Shaye; DeAngelis, Donald L.; Yurek, Simeon; Trexler, Joel C.; Graf, William L.; Reed, Denise J.

    2015-01-01

    Large-scale aquatic ecosystem restoration is increasing and is often controversial because of the economic costs involved, with the focus of the controversies gravitating to the modeling of fish responses. We present a scheme for best practices in selecting, implementing, interpreting, and reporting of fish modeling designed to assess the effects of restoration actions on fish populations and aquatic food webs. Previous best practice schemes that tended to be more general are summarized, and they form the foundation for our scheme that is specifically tailored for fish and restoration. We then present a 31-step scheme, with supporting text and narrative for each step, which goes from understanding how the results will be used through post-auditing to ensure the approach is used effectively in subsequent applications. We also describe 13 concepts that need to be considered in parallel to these best practice steps. Examples of these concepts include: life cycles and strategies; variability and uncertainty; nonequilibrium theory; biological, temporal, and spatial scaling; explicit versus implicit representation of processes; and model validation. These concepts are often not considered or not explicitly stated and casual treatment of them leads to mis-communication and mis-understandings, which in turn, often underlie the resulting controversies. We illustrate a subset of these steps, and their associated concepts, using the three case studies of Glen Canyon Dam on the Colorado River, the wetlands of coastal Louisiana, and the Everglades. Use of our proposed scheme will require investment of additional time and effort (and dollars) to be done effectively. We argue that such an investment is well worth it and will more than pay back in the long run in effective and efficient restoration actions and likely avoided controversies and legal proceedings.

  6. A System Thinking Model Proposal for Enterprise Application Integration (EAI Evaluation Completeness

    Directory of Open Access Journals (Sweden)

    Irene Nakiyimba

    2014-01-01

    Full Text Available Research has identified a number of approaches for evaluating Enterprise Application Integration (EAI. The majority of these approaches focus primarily on the technical functional and non-functional capabil¬ities of an EAI solution. Although, where the technical dimensions have received considerable attention from researchers, other dimensions needed for EAI evaluation, such as stakeholder feedback, have not re¬ceived explicit consideration. As a result, attaining a consummate EAI solution is still a major challenge for many enterprises. The current EAI evaluation models simply provide piecemeal insights towards the evaluation criteria variables from limited stakeholder perceptions and do not help to understand EAI evaluation as a dynamic, feedback, time based and non-linear problem. Different stakeholders view the outcome of an EAI project from different perspectives and therefore will more likely than not arrive at different conclusions. To achieve a consensus among stakeholder perceptions, we represent EAI evaluation as a feedback analysis problem from multi-stakeholder perceptions for proper alignment with business goals, vision and mission. This paper proposes the application of System Dynamics (SD model towards guiding policy analysis for evaluating criteria factors from multi-stakeholders perceptions for EAI adoption; this will provide for holistic evaluation where emphasis is the importance of evaluation as whole (not piece meal perceptions and the interdependence of evaluation criteria factors from the diverse stakeholder perceptions is analyzed. In this paper we present a case-study performed at a large portion of the East African banking system. A total of 800 responses to questionnaires are analyzed to formulate a systems thinking model, which in turn allows us to analyze feedback loops between different stakeholders with distinct evaluation criteria. Findings result in a structured and holistic systems thinking model which

  7. Radiographic features of Golden Retriever muscular dystrophy.

    Science.gov (United States)

    Brumitt, Jason W; Essman, Stephanie C; Kornegay, Joe N; Graham, John P; Weber, William J; Berry, Clifford R

    2006-01-01

    Golden Retriever muscular dystrophy is an inherited, degenerative myopathy due to the absence of dystrophin and is used as a model of Duchenne muscular dystrophy of young boys. This report describes the radiographic abnormalities of Golden Retriever muscular dystrophy in 26 dogs. The thoracic abnormalities included diaphragmatic asymmetry (18/26), diaphragmatic undulation (18/26), and gastro-esophageal hiatal hernia (6/26). Pelvic abnormalities included narrowing of the body of the ilia (14/19), ventral deviation and curvature of the tuber ischii (14/19), elongation of the obturator foramen with a decrease in opacity of the surrounding bone (12/19), and lateral flaring of the wings of the ilia (12/19). Abdominal abnormalities consisted of hepatomegaly (14/22) and poor serosal detail (12/22). The unique thoracic abnormalities were a consistent finding in affected Golden Retriever muscular dystrophy dogs. The diagnosis of muscular dystrophy should be included in the differential list if the combination of diaphragm undulation and asymmetry, and gastro-esophageal hiatal hernia are identified. These diaphragmatic abnormalities are related to hypertrophy and hyperplasia of the diaphragm. Additionally, the skeletal changes of pelvic tilt, elongation of the pelvis, widening of the obturator foramina and thinning of the ischiatic tables appear to be specific to Golden Retriever muscular dystrophy in dogs. These pelvic abnormalities are most likely secondary to bone remodeling associated with the progressive skeletal myopathy and subsequent contracture/fibrosis.

  8. Segmentation of radiographic images under topological constraints: application to the femur.

    Science.gov (United States)

    Gamage, Pavan; Xie, Sheng Quan; Delmas, Patrice; Xu, Wei Liang

    2010-09-01

    A framework for radiographic image segmentation under topological control based on two-dimensional (2D) image analysis was developed. The system is intended for use in common radiological tasks including fracture treatment analysis, osteoarthritis diagnostics and osteotomy management planning. The segmentation framework utilizes a generic three-dimensional (3D) model of the bone of interest to define the anatomical topology. Non-rigid registration is performed between the projected contours of the generic 3D model and extracted edges of the X-ray image to achieve the segmentation. For fractured bones, the segmentation requires an additional step where a region-based active contours curve evolution is performed with a level set Mumford-Shah method to obtain the fracture surface edge. The application of the segmentation framework to analysis of human femur radiographs was evaluated. The proposed system has two major innovations. First, definition of the topological constraints does not require a statistical learning process, so the method is generally applicable to a variety of bony anatomy segmentation problems. Second, the methodology is able to handle both intact and fractured bone segmentation. Testing on clinical X-ray images yielded an average root mean squared distance (between the automatically segmented femur contour and the manual segmented ground truth) of 1.10 mm with a standard deviation of 0.13 mm. The proposed point correspondence estimation algorithm was benchmarked against three state-of-the-art point matching algorithms, demonstrating successful non-rigid registration for the cases of interest. A topologically constrained automatic bone contour segmentation framework was developed and tested, providing robustness to noise, outliers, deformations and occlusions.

  9. Segmentation of radiographic images under topological constraints: application to the femur

    International Nuclear Information System (INIS)

    Gamage, Pavan; Xie, Sheng Quan; Delmas, Patrice; Xu, Wei Liang

    2010-01-01

    A framework for radiographic image segmentation under topological control based on two-dimensional (2D) image analysis was developed. The system is intended for use in common radiological tasks including fracture treatment analysis, osteoarthritis diagnostics and osteotomy management planning. The segmentation framework utilizes a generic three-dimensional (3D) model of the bone of interest to define the anatomical topology. Non-rigid registration is performed between the projected contours of the generic 3D model and extracted edges of the X-ray image to achieve the segmentation. For fractured bones, the segmentation requires an additional step where a region-based active contours curve evolution is performed with a level set Mumford-Shah method to obtain the fracture surface edge. The application of the segmentation framework to analysis of human femur radiographs was evaluated. The proposed system has two major innovations. First, definition of the topological constraints does not require a statistical learning process, so the method is generally applicable to a variety of bony anatomy segmentation problems. Second, the methodology is able to handle both intact and fractured bone segmentation. Testing on clinical X-ray images yielded an average root mean squared distance (between the automatically segmented femur contour and the manual segmented ground truth) of 1.10 mm with a standard deviation of 0.13 mm. The proposed point correspondence estimation algorithm was benchmarked against three state-of-the-art point matching algorithms, demonstrating successful non-rigid registration for the cases of interest. A topologically constrained automatic bone contour segmentation framework was developed and tested, providing robustness to noise, outliers, deformations and occlusions. (orig.)

  10. Segmentation of radiographic images under topological constraints: application to the femur

    Energy Technology Data Exchange (ETDEWEB)

    Gamage, Pavan; Xie, Sheng Quan [University of Auckland, Department of Mechanical Engineering (Mechatronics), Auckland (New Zealand); Delmas, Patrice [University of Auckland, Department of Computer Science, Auckland (New Zealand); Xu, Wei Liang [Massey University, School of Engineering and Advanced Technology, Auckland (New Zealand)

    2010-09-15

    A framework for radiographic image segmentation under topological control based on two-dimensional (2D) image analysis was developed. The system is intended for use in common radiological tasks including fracture treatment analysis, osteoarthritis diagnostics and osteotomy management planning. The segmentation framework utilizes a generic three-dimensional (3D) model of the bone of interest to define the anatomical topology. Non-rigid registration is performed between the projected contours of the generic 3D model and extracted edges of the X-ray image to achieve the segmentation. For fractured bones, the segmentation requires an additional step where a region-based active contours curve evolution is performed with a level set Mumford-Shah method to obtain the fracture surface edge. The application of the segmentation framework to analysis of human femur radiographs was evaluated. The proposed system has two major innovations. First, definition of the topological constraints does not require a statistical learning process, so the method is generally applicable to a variety of bony anatomy segmentation problems. Second, the methodology is able to handle both intact and fractured bone segmentation. Testing on clinical X-ray images yielded an average root mean squared distance (between the automatically segmented femur contour and the manual segmented ground truth) of 1.10 mm with a standard deviation of 0.13 mm. The proposed point correspondence estimation algorithm was benchmarked against three state-of-the-art point matching algorithms, demonstrating successful non-rigid registration for the cases of interest. A topologically constrained automatic bone contour segmentation framework was developed and tested, providing robustness to noise, outliers, deformations and occlusions. (orig.)

  11. Fractures of the hook of hamate: radiographic signs

    International Nuclear Information System (INIS)

    Norman, A.; Nelson, J.; Green, S.

    1985-01-01

    Isolated fractures of the hamulus, formerly considered rare, are being seen more frequently. Many of these injuries are sports related, particularly in golf, tennis, racquetball and baseball players. Failure to make an early diagnosis can result in severe pain and sometimes incapacitating disability. The authors studied the clinical and radiological findings in 12 patients who had fracture of the hook of the hamate. The proposed three radiographic signs of fracture that are readily seen on routine PA projections: absence of the hook of the hamate; sclerosis of the hook; and lack of cortical density, i.e., barely visible outline, of the hamulus

  12. Proposed Model for Translational Research at a Teaching-Intensive College of Pharmacy.

    Science.gov (United States)

    Ulrich, Erin; Grady, Sarah; Vonderhaar, Jacqueline; Ruplin, Andrew

    2017-08-08

    Many American colleges of pharmacy are small, private, teaching institutions. Faculty are required to maintain a research agenda, although the publication quota is less compared with their publicly funded college of pharmacy peers. Faculty at these smaller schools conduct research with very little internal or external funding. This tends to lead to smaller, less impactful research findings. Translational research is becoming popular for research faculty as it bridges theory to practice. The Knowledge-to-Action (KTA) framework presents the steps to conduct translational research. To apply and determine if the KTA framework would be able to produce practice-impactful research at an institution that does not depend on grant funding as part of faculty research agendas. An interdisciplinary team was formed with providers at the clinical faculty's practice site. As the team moved through the KTA steps, authors documented the roles of each team member. It was clear that many different types of teams were formed throughout the KTA process. These teams were then categorized according to the Interdisciplinary Teamwork System. The final result is a proposed model of types of teams and required member roles that are necessary within each KTA step for faculty to conduct practice-impactful research at a small, private, teaching institution without substantial grant funding awards. Applying the KTA framework, two impactful original research manuscripts were developed over two academic years. Furthermore, the practitioners at the clinical faculty member's site were very pleased with the ease of conducting research, as they were never required to take a lead role. In addition, both faculty members alternated lead and support role allowing for a decreased burden of workload while producing theory-driven research. The KTA framework can create a model for translational research and may be particularly beneficial to small teaching institutions to conduct impactful research. Copyright

  13. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  14. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  15. Parent and family impact of autism spectrum disorders: a review and proposed model for intervention evaluation.

    Science.gov (United States)

    Karst, Jeffrey S; Van Hecke, Amy Vaughan

    2012-09-01

    Raising a child with an autism spectrum disorder (ASD) can be an overwhelming experience for parents and families. The pervasive and severe deficits often present in children with ASD are associated with a plethora of difficulties in caregivers, including decreased parenting efficacy, increased parenting stress, and an increase in mental and physical health problems compared with parents of both typically developing children and children with other developmental disorders. In addition to significant financial strain and time pressures, high rates of divorce and lower overall family well-being highlight the burden that having a child with an ASD can place on families. These parent and family effects reciprocally and negatively impact the diagnosed child and can even serve to diminish the positive effects of intervention. However, most interventions for ASD are evaluated only in terms of child outcomes, ignoring parent and family factors that may have an influence on both the immediate and long-term effects of therapy. It cannot be assumed that even significant improvements in the diagnosed child will ameliorate the parent and family distress already present, especially as the time and expense of intervention can add further family disruption. Thus, a new model of intervention evaluation is proposed, which incorporates these factors and better captures the transactional nature of these relationships.

  16. [Proposed difficult airway teaching methodology. Presentation of an interactive fresh frozen cadaver model].

    Science.gov (United States)

    Catalá Bauset, J C; de Andres Ibañez, J A; Valverde Navarro, A; Martinez Soriano, F

    2014-04-01

    The aim of this paper is to present a methodology based on the use of fresh-frozen cadavers for training in the management of the airway, and to evaluate the degree of satisfaction among learning physicians. About 6 fresh-frozen cadavers and 14 workstations were prepared where participants were trained in the different skills needed for airway management. The details of preparation of the cadavers are described. The level of satisfaction of the participant was determined using a Likert rating scale of 5 points, at each of the 14 stations, as well as the overall assessment and clinical usefulness of the course. The mean overall evaluation of the course and its usefulness was 4.75 and 4.9, out of 5, respectively. All parts of the course were rated above 4 out of 5. The high level of satisfaction of the course remained homogeneous in the 2 editions analysed. The overall satisfaction of the course was not finally and uniquely determined by any of its particular parts. The fresh cadaver model for training physicians in techniques of airway management is a proposal satisfactory to the participant, and with a realism that approaches the live patient. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  17. Integrated Multiregional Analysis Proposing a New Model of Colorectal Cancer Evolution

    Science.gov (United States)

    Niida, Atsushi; Shimamura, Teppei; Hirata, Hidenari; Sugimachi, Keishi; Sawada, Genta; Iwaya, Takeshi; Kurashige, Junji; Shinden, Yoshiaki; Iguchi, Tomohiro; Eguchi, Hidetoshi; Chiba, Kenichi; Shiraishi, Yuichi; Nagae, Genta; Yoshida, Kenichi; Nagata, Yasunobu; Haeno, Hiroshi; Yamamoto, Hirofumi; Ishii, Hideshi; Doki, Yuichiro; Iinuma, Hisae; Sasaki, Shin; Nagayama, Satoshi; Yamada, Kazutaka; Yachida, Shinichi; Kato, Mamoru; Shibata, Tatsuhiro; Oki, Eiji; Saeki, Hiroshi; Shirabe, Ken; Oda, Yoshinao; Maehara, Yoshihiko; Komune, Shizuo; Mori, Masaki; Suzuki, Yutaka; Yamamoto, Ken; Aburatani, Hiroyuki; Ogawa, Seishi; Miyano, Satoru; Mimori, Koshi

    2016-01-01

    Understanding intratumor heterogeneity is clinically important because it could cause therapeutic failure by fostering evolutionary adaptation. To this end, we profiled the genome and epigenome in multiple regions within each of nine colorectal tumors. Extensive intertumor heterogeneity is observed, from which we inferred the evolutionary history of the tumors. First, clonally shared alterations appeared, in which C>T transitions at CpG site and CpG island hypermethylation were relatively enriched. Correlation between mutation counts and patients’ ages suggests that the early-acquired alterations resulted from aging. In the late phase, a parental clone was branched into numerous subclones. Known driver alterations were observed frequently in the early-acquired alterations, but rarely in the late-acquired alterations. Consistently, our computational simulation of the branching evolution suggests that extensive intratumor heterogeneity could be generated by neutral evolution. Collectively, we propose a new model of colorectal cancer evolution, which is useful for understanding and confronting this heterogeneous disease. PMID:26890883

  18. The Brazilian Unified National Health System: Proposal of a Cost-effectiveness Evaluation Model

    Directory of Open Access Journals (Sweden)

    Lilian Ribeiro de Oliveira

    2016-04-01

    Full Text Available The Brazilian Unified National Health System (Sistema Único de Saúde [SUS] is in a prominent position compared to the existing social policies. One of the new tools used by SUS is known as Performance Index of the Unified Health System (Índice de Desempenho do Sistema Único de Saúde [IDSUS], which is intended to measure the performance of each municipality. Therefore, the aim of this study was to propose a model of cost-effectiveness to compare IDSUS performance against total revenues achieved in Homogeneous Group 2, consisting of 94 municipalities and analysed using data from IDSUS and the System Information of the Public Budget for Health Care (Sistema de Informação do Orçamento Público em Saúde [SIOPS] for the year 2011. After structuring this data, we carried out descriptive statistical and cluster analysis in order to group similar municipalities in accordance with established variables: IDSUS performance, population and total revenue in health per capita. Even with the division of municipalities into homogeneous groups and after using variables such as population and revenue to regroup them, the results showed there are municipalities with heterogeneous characteristics. Another finding is in the use and intersection of two distinct databases (IDSUS and SIOPS, which allowed for visualizing the impact of health care revenue on the municipalities performance.

  19. A qualitative model for strategic analysis of organizations. Application and alternative proposal on a study case

    Directory of Open Access Journals (Sweden)

    Santiago Ferro Moreno

    2015-12-01

    Full Text Available The strategic analysis of organizations is based on the internal and external environments, in order to identify positive and negative variables and factors. The interrelation and timing of these strategic forces are essential to create alternative solutions that tend to achieve the organizational objectives.The normative prospective has theorical and methodological foundations to create a desired future and from it, be able to identify impelling and restraining forces that have influence on the particular problematic situation (go from the current situation to a better one in a certain time.The aim of this article is to analyze on a strategic way a real case with a normative-prospective model that considers the temporal dynamics of the factors impact and variables in time allowing to suggest alternative solutions.Semi-structured interviews were performed with all the employees of this case and structured observations and workshops with the commercial and general management.In consequence, with the results, the desired, current and improved situations were built. Additionally, forces were identified classified and appreciated and lastly solutions were suggested. With the proposed prospective method, alternative solutions could be constructed in order to settle temporary organizational objectives. No constraints were found to use the current method in other cases.Keywords: Strategic forces, Normative prospective, Problematic situations, Strategies

  20. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  1. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  2. Evaluation of six NEHRP B/C crustal amplification models proposed for use in western North America

    Science.gov (United States)

    Boore, David; Campbell, Kenneth W.

    2016-01-01

    We evaluate six crustal amplification models based on National Earthquake Hazards Reduction Program (NEHRP) B/C crustal profiles proposed for use in western North America (WNA) and often used in other active crustal regions where crustal properties are unknown. One of the models is based on an interpolation of generic rock velocity profiles previously proposed for WNA and central and eastern North America (CENA), in conjunction with material densities based on an updated velocity–density relationship. A second model is based on the velocity profile used to develop amplification factors for the Next Generation Attenuation (NGA)‐West2 project. A third model is based on a near‐surface velocity profile developed from the NGA‐West2 site database. A fourth model is based on velocity and density profiles originally proposed for use in CENA but recently used to represent crustal properties in California. We propose two alternatives to this latter model that more closely represent WNA crustal properties. We adopt a value of site attenuation (κ0) for each model that is either recommended by the author of the model or proposed by us. Stochastic simulation is used to evaluate the Fourier amplification factors and their impact on response spectra associated with each model. Based on this evaluation, we conclude that among the available models evaluated in this study the NEHRP B/C amplification model of Boore (2016) best represents median crustal amplification in WNA, although the amplification models based on the crustal profiles of Kamai et al. (2013, 2016, unpublished manuscript, see Data and Resources) and Yenier and Atkinson (2015), the latter adjusted to WNA crustal properties, can be used to represent epistemic uncertainty.

  3. A new approach for modeling the peak utility impacts from a proposed CUAC standard

    Energy Technology Data Exchange (ETDEWEB)

    LaCommare, Kristina Hamachi; Gumerman, Etan; Marnay, Chris; Chan, Peter; Coughlin, Katie

    2004-08-01

    This report describes a new Berkeley Lab approach for modeling the likely peak electricity load reductions from proposed energy efficiency programs in the National Energy Modeling System (NEMS). This method is presented in the context of the commercial unitary air conditioning (CUAC) energy efficiency standards. A previous report investigating the residential central air conditioning (RCAC) load shapes in NEMS revealed that the peak reduction results were lower than expected. This effect was believed to be due in part to the presence of the squelch, a program algorithm designed to ensure changes in the system load over time are consistent with the input historic trend. The squelch applies a system load-scaling factor that scales any differences between the end-use bottom-up and system loads to maintain consistency with historic trends. To obtain more accurate peak reduction estimates, a new approach for modeling the impact of peaky end uses in NEMS-BT has been developed. The new approach decrements the system load directly, reducing the impact of the squelch on the final results. This report also discusses a number of additional factors, in particular non-coincidence between end-use loads and system loads as represented within NEMS, and their impacts on the peak reductions calculated by NEMS. Using Berkeley Lab's new double-decrement approach reduces the conservation load factor (CLF) on an input load decrement from 25% down to 19% for a SEER 13 CUAC trial standard level, as seen in NEMS-BT output. About 4 GW more in peak capacity reduction results from this new approach as compared to Berkeley Lab's traditional end-use decrement approach, which relied solely on lowering end use energy consumption. The new method has been fully implemented and tested in the Annual Energy Outlook 2003 (AEO2003) version of NEMS and will routinely be applied to future versions. This capability is now available for use in future end-use efficiency or other policy analysis

  4. Reconstruction of pseudo three-dimensional dental image from dental panoramic radiograph and tooth surface shape

    International Nuclear Information System (INIS)

    Imura, Masataka; Kuroda, Yoshihiro; Oshiro, Osamu; Kuroda, Tomohiro; Kagiyama, Yoshiyuki; Yagi, Masakazu; Takada, Kenji; Azuma, Hiroko

    2010-01-01

    Three-dimensional volume data set is useful for diagnosis in dental treatments. However, to obtain three-dimensional images of a dental arch in general dental clinics is difficult. In this paper, we propose a method to reconstruct pseudo three-dimensional dental images from a dental panoramic radiograph and a tooth surface shape which can be obtained from three dimensional shape measurement of a dental impression. The proposed method finds an appropriate curved surface on which the dental panoramic radiograph is mapped by comparing a virtual panoramic image made from a tooth surface shape to a real panoramic radiograph. The developed pseudo three-dimensional dental images give clear impression of patient's dental condition. (author)

  5. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  6. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  7. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  8. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  9. Proposal of the mathematical model of the aquifer for interpretation of measurements of natural isotopes in the water

    International Nuclear Information System (INIS)

    Nawalany, M.

    1975-01-01

    Mathematical models applied in isotope hydrology are presented in the paper. The most commonly used deterministic models are discussed in the first part of the paper including the piston flow and good mixing models. The model of nonideal mixing is introduced by the author into the hydrological considerations. This model is a generalization of the good mixing model and allows for different processes of mixing of natural isotopes in waters of hydrological systems. The most important stochastic model i.e. the dispersive model is discussed too. The ''three-velocities'' model is proposed the first time by the author. The ''three-velocities'' model differs from the other ones in following properties: it includes finite flow velocity of the tracer particles, it takes into account the presence of stagnant water, it satisfied the law of fluid continuity, it is convergent to the piston-flow model in limit. However the model proposed describes dispersion phenomenon and satisfied the tracer conservation law (i.e. standarization) - the two properties characteristic of all the models. The author's strong belief is that the user (hydrologist) having at his disposal given below review of the models will be able to choose the most adequate model in given hydrological conditions. (author)

  10. Formation of potential antigens from radiographic contrast media

    International Nuclear Information System (INIS)

    Nilsson, R.; Ehrenberg, L.; Fedorcsak, I.

    1987-01-01

    The use of radiographic contrast media is occasionally accompanied by more or less serious adverse effects, evidently of complex etiology, following intravascular administration. Some of these reactions are suspected of having an allergic basis. The in vitro and in vivo formation of iodinated serum proteins following gamma irradiation in the presence of two commonly used radiographic contrast media is demonstrated. Non-toxic concentrations of ascorbate present during the irradiation is shown to prevent the formation of such iodo-proteins in vitro as well as in vivo. The amounts of potentially antigenic iodoprotein formed during radiographic procedures will certainly be very small, but this quantity may be sufficient to elicit a hypersensitivity reaction in cases when an individual has been previously sensitized to immunologically similar iodo-proteins, a mechanism that could account for certain rare and unpredictable reations. The radiation induced formation of iodo-proteins may also serve as a model for the formation of iodine containing antigens mediated by a free radical mechanism, i.e. in the metabolism of iodinated compounds like erythrosine, a widely used colouring agent for certain foods. (orig.)

  11. A computational technique to measure fracture callus in radiographs.

    Science.gov (United States)

    Lujan, Trevor J; Madey, Steven M; Fitzpatrick, Dan C; Byrd, Gregory D; Sanderson, Jason M; Bottlang, Michael

    2010-03-03

    Callus formation occurs in the presence of secondary bone healing and has relevance to the fracture's mechanical environment. An objective image processing algorithm was developed to standardize the quantitative measurement of periosteal callus area in plain radiographs of long bone fractures. Algorithm accuracy and sensitivity were evaluated using surrogate models. For algorithm validation, callus formation on clinical radiographs was measured manually by orthopaedic surgeons and compared to non-clinicians using the algorithm. The algorithm measured the projected area of surrogate calluses with less than 5% error. However, error will increase when analyzing very small areas of callus and when using radiographs with low image resolution (i.e. 100 pixels per inch). The callus size extracted by the algorithm correlated well to the callus size outlined by the surgeons (R2=0.94, p<0.001). Furthermore, compared to clinician results, the algorithm yielded results with five times less inter-observer variance. This computational technique provides a reliable and efficient method to quantify secondary bone healing response. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. Advanced practice for therapy radiographers - A discussion paper

    International Nuclear Information System (INIS)

    Eddy, Angela

    2008-01-01

    Purpose: The purpose of this discussion paper is to explore issues related to advanced practice for therapy radiographers. Key themes: The paper will focus on key themes that have impacted on advanced practice for therapy radiographers such as government initiatives and policy, confounding terminology associated with advanced practice such as role extension, role expansion, role development, and expert practice. The theory and development of expert practice is explored and paralleled to existing roles in therapy using the Benner model to define stages of professional development and competence. Evidence for advanced practice, and education and training will also be explored. All of these issues will be considered within the perspective of the current clinical and political environment that therapy radiographers operate in. Conclusions: The application of advanced practice can and should incorporate elements of role extension and role development, with some tangible skills ladder to guide and shape the development of potential consultant practitioners. There is a need to identify the current position of advanced practice nationally, and to monitor existing and emerging roles, possibly though a longitudinal study. The skill mix as a whole within departments need to be part of an ongoing evaluation with close collaboration between the professional body, departmental managers and higher education institutes to develop curricula to support existing and emerging roles. There are also key lessons to be learned from other professions with more experience with advanced practitioners if recruitment and retention is not going to continue to be a problem

  13. Advocating for School Psychologists in Response to the APA's Proposed "Model Act for State Licensure of Psychologists"

    Science.gov (United States)

    Skalski, Anastasia Kalamaros

    2009-01-01

    On March 6, 2009, the APA Model Licensure Act Task Force released its second draft of the policy document known as the proposed "Model Act for State Licensure of Psychologists". This policy document serves as guidance to state legislatures for how they should set up their psychology licensing laws. The general expectations promoted in the model…

  14. Accuracy of chest radiographs in the emergency diagnosis of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Studler, Ueli; Kretzschmar, Martin; Steinbrich, Wolfgang [University Hospital Basel, Department of Radiology, Basel (Switzerland); Christ, Michael; Breidthardt, Tobias; Noveanu, Markus; Perruchoud, Andre P.; Mueller, Christian [University Hospital Basel, Department of Internal Medicine, Basel (Switzerland); Schoetzau, Andreas [Institute of Biostatistics, Basel (Switzerland)

    2008-08-15

    The purpose of this study was to determine the diagnostic accuracy of chest radiographic findings of heart failure (HF) in current patients presenting with dyspnea in the emergency department. In a secondary analysis of the BASEL study, initial chest radiographs of 277 patients with acute dyspnea were evaluated by two radiologists blinded to the adjudicated diagnosis (56% had the final diagnosis of HF). Predefined radiographic criteria of HF were used. Statistical analysis included receiver-operating characteristic (ROC) analysis and calculation of a logistic regression model including B-type natriuretic peptide (BNP) levels. The reader's overall impression showed the highest area under the ROC curve for the diagnosis of HF in both supine and erect patient positions (0.855 and 0.857). Among individual radiographic findings, peribronchial cuffing in the supine position (0.829) showed the highest accuracies. The lowest accuracy was found for the vascular pedicle width in the supine position (0.461). Logistic regression analysis showed no significant differences between the reader's overall impression, the radiographic model, and BNP testing. In our study, the combination of radiographic features provided valuable information and was of comparable accuracy as BNP-testing for the diagnosis of HF. (orig.)

  15. Leveraging ISI Multi-Model Prediction for Navy Operations: Proposal to the Office of Naval Research

    Science.gov (United States)

    2013-09-30

    Operations: Proposal to the Office of Naval Research” PI: Benjamin Kirtman University of Miami – RSMAS Meteorology and Physical Oceanography...Prediction for Navy Operations: Proposal to the Office of Naval Research 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d

  16. Modeling commuter preferences for the proposed bus rapid transit in Dar-es-Salaam

    NARCIS (Netherlands)

    Nkurunziza, A.; Zuidgeest, M.H.P.; Brussel, M.J.G.; van Maarseveen, M.F.A.M.

    2012-01-01

    The paper analyzes individual commuter preferences towards the proposed bus rapid transit (BRT) system in Dar-es-Salaam, Tanzania. The objective of the survey was to identify how commuters perceive and value the proposed BRT service quality attributes. A stated preference survey of potential users

  17. A proposal on alternative sampling-based modeling method of spherical particles in stochastic media for Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Lee, Jae Yong; KIm, Do Hyun; Kim, Jong Kyung [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of); Noh, Jae Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-08-15

    Chord length sampling method in Monte Carlo simulations is a method used to model spherical particles with random sampling technique in a stochastic media. It has received attention due to the high calculation efficiency as well as user convenience; however, a technical issue regarding boundary effect has been noted. In this study, after analyzing the distribution characteristics of spherical particles using an explicit method, an alternative chord length sampling method is proposed. In addition, for modeling in finite media, a correction method of the boundary effect is proposed. Using the proposed method, sample probability distributions and relative errors were estimated and compared with those calculated by the explicit method. The results show that the reconstruction ability and modeling accuracy of the particle probability distribution with the proposed method were considerably high. Also, from the local packing fraction results, the proposed method can successfully solve the boundary effect problem. It is expected that the proposed method can contribute to the increasing of the modeling accuracy in stochastic media.

  18. A proposal on alternative sampling-based modeling method of spherical particles in stochastic media for Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kim, Song Hyun; Lee, Jae Yong; KIm, Do Hyun; Kim, Jong Kyung; Noh, Jae Man

    2015-01-01

    Chord length sampling method in Monte Carlo simulations is a method used to model spherical particles with random sampling technique in a stochastic media. It has received attention due to the high calculation efficiency as well as user convenience; however, a technical issue regarding boundary effect has been noted. In this study, after analyzing the distribution characteristics of spherical particles using an explicit method, an alternative chord length sampling method is proposed. In addition, for modeling in finite media, a correction method of the boundary effect is proposed. Using the proposed method, sample probability distributions and relative errors were estimated and compared with those calculated by the explicit method. The results show that the reconstruction ability and modeling accuracy of the particle probability distribution with the proposed method were considerably high. Also, from the local packing fraction results, the proposed method can successfully solve the boundary effect problem. It is expected that the proposed method can contribute to the increasing of the modeling accuracy in stochastic media

  19. Cigarette smoking and depression comorbidity: systematic review and proposed theoretical model.

    Science.gov (United States)

    Mathew, Amanda R; Hogarth, Lee; Leventhal, Adam M; Cook, Jessica W; Hitsman, Brian

    2017-03-01

    Despite decades of research on co-occurring smoking and depression, cessation rates remain consistently lower for depressed smokers than for smokers in the general population, highlighting the need for theory-driven models of smoking and depression. This paper provides a systematic review with a particular focus upon psychological states that disproportionately motivate smoking in depression, and frame an incentive learning theory account of smoking-depression co-occurrence. We searched PubMed, Scopus, PsychINFO and CINAHL to December 2014, which yielded 852 papers. Using pre-established eligibility criteria, we identified papers focused on clinical issues and motivational mechanisms underlying smoking in established, adult smokers (i.e. maintenance, quit attempts and cessation/relapse) with elevated symptoms of depression. Two reviewers determined independently whether papers met review criteria. We included 297 papers in qualitative synthesis. Our review identified three primary mechanisms that underlie persistent smoking among depressed smokers: low positive affect, high negative affect and cognitive impairment. We propose a novel application of incentive learning theory which posits that depressed smokers experience greater increases in the expected value of smoking in the face of these three motivational states, which promotes goal-directed choice of smoking behavior over alternative actions. The incentive learning theory accounts for current evidence on how depression primes smoking behavior and provides a unique framework for conceptualizing psychological mechanisms of smoking maintenance among depressed smokers. Treatment should focus upon correcting adverse internal states and beliefs about the high value of smoking in those states to improve cessation outcomes for depressed smokers. © 2016 Society for the Study of Addiction.

  20. Analysis of Participation Banks in Turkey in Terms of Agency Theory and a Model Proposal

    Directory of Open Access Journals (Sweden)

    Musa GÜN

    2016-04-01

    Full Text Available The agency theory considers the problems between agents and principal and aims to reduce the agency costs arising from these problems.  The theory could be applied in various fields and in many different areas where principal-agent relations occur. Participation banks in Turkey operating banking services based on Islamic principals are able to implement many different banking facilities. They could be regarded as supplementary alternatives to the conventional banks and thus, participation banks provide depth and financial product range in the banking sector.  There are many different studies on several fields and subjects about participation banks and Islamic banks both in national and in international literature.  However, the studies discussing the fatwa structure in the context of agency theory are very rare especially for the participation banks in Turkey. Thus, this study examines the Sariah advisory board mechanism of the participation banks in particular within the scope of agency problems and it focuses on a model proposal that could resolve agency cost. In Turkey, there is not a nationwide nor a Shariah agency or institution which control, regulate and/or supervise the services, operations, and activities of the participation banks, in accordance with Islamic concepts. In this context, the establishment of an independent Islamic Supervisory Council will help to reduce agency costs. Furthermore, sustainability and stability of Islamic financial markets will increase together with issuing appropriate financial products in compliance with Shariah principles and thus the Council will help Istanbul to achieve the goal of being the financial center.

  1. A PROPOSAL FOR A SUSTAINABLE MODEL BASED UPON UNDERWATER TOURISM RESEARCH IN AYVALIK

    Directory of Open Access Journals (Sweden)

    A. GÖKDENİZ

    2013-03-01

    Full Text Available Underwater sports are the activities being done with the aims of witnessing the beauties, hunting, taking photos, the ecology and the archaeology of underwater analysing or finding out the human being’s boundaries by improving the physical and psychological skills of men. The initial aim of this project is to increase the underwater flora and the fauna heritage of Ayvalık and to bring them in tourism. Ayvalık is on the west coast of Turkey. It is getting more and more famous with its underwater richness. Also, to form a new underwater sports centre in order to contribute to the improvement of the region. By providing visual attractiveness, the tourists related to underwater sports will pay attention to Ayvalık and underwater tourism will contribute much to the economy of the region. The aim of this project is to improve the underwater sports which is now a hobby than a sport. In Ayvalık Underwater World study, we dealt with 247 divers and 4 underwater sports club. In this study, we analysed the expectation, satisfaction, demographic and economic level of 247 divers about the services in the region. Interview technique has been used in the study on the 4 underwater sports clubs which are hosting divers. As a conclusion, a report has been prepared in which detailed information and proposals are presented by developing a sustainable marketing model concerned with the underwater sports for those who want to possess information, shareholders of the sector and make analyse about tourism.

  2. A proposed agglomerate model for oxygen reduction in the catalyst layer of proton exchange membrane fuel cells

    International Nuclear Information System (INIS)

    Zhang, Xiaoxian; Gao, Yuan; Ostadi, Hossein; Jiang, Kyle; Chen, Rui

    2014-01-01

    Highlights: • We developed a new agglomerate model to describe oxygen reduction reaction. • We showed how to calculate the model parameters from catalyst layer structure. • We verified the agglomerate model. - Abstract: Oxygen diffusion and reduction in the catalyst layer of PEM fuel cell is an important process in fuel cell modelling, but models able to link the reduction rate to catalyst-layer structure are lack; this paper makes such an effort. We first link the average reduction rate over the agglomerate within a catalyst layer to a probability that an oxygen molecule, which is initially on the agglomerate surface, will enter and remain in the agglomerate at any time in the absence of any electrochemical reaction. We then propose a method to directly calculate distribution function of this probability and apply it to two catalyst layers with contrasting structures. A formula is proposed to describe these calculated distribution functions, from which the agglomerate model is derived. The model has two parameters and both can be independently calculated from catalyst layer structures. We verify the model by first showing that it is an improvement and able to reproduce what the spherical model describes, and then testing it against the average oxygen reductions directly calculated from pore-scale simulations of oxygen diffusion and reaction in the two catalyst layers. The proposed model is simple, but significant as it links the average oxygen reduction to catalyst layer structures, and its two parameters can be directly calculated rather than by calibration

  3. A proposed cell model for multiple-occurrence regional landslide events: Implications for landslide susceptibility mapping

    Science.gov (United States)

    Crozier, M. J.

    2017-10-01

    Multiple-occurrence regional landslide events (MORLEs) consist of hundreds to thousands of shallow landslides occurring more or less simultaneously within defined areas, ranging from tens to thousands of square kilometres. While MORLEs can be triggered by rainstorms and earthquakes, this paper is confined to those landslide events triggered by rainstorms. Globally, MORLEs occur in a range of geological settings in areas of moderate to steep slopes subject to intense rainstorms. Individual landslides in rainstorm-triggered events are dominantly small, shallow debris and earth flows, and debris and earth slides involving regolith or weathered bedrock. The model used to characterise these events assumes that energy distribution within the event area is represented on the land surface by a cell structure; with maximum energy expenditure within an identifiable core and rapid dissipation concentrically away from the centre. The version of the model presented here has been developed for rainfall-triggered landslide events. It proposes that rainfall intensity can be used to determine different critical landslide response zones within the cell (referred to as core, middle, and periphery zones). These zones are most readily distinguished by two conditions: the proportion of the slope that fails and the particular type of the slope stability factor that assumes dominance in determining specific sites of landslide occurrence. The latter condition means that the power of any slope stability factor to distinguish between stable and unstable sites varies throughout the affected area in accordance with the landslide response zones within the cell; certain factors critical for determining the location of landslide sites in one part of the event area have little influence in other parts of the event area. The implication is that landslide susceptibility maps (and subsequently derived mitigation measures) based on conventional slope stability factors may have only limited validity

  4. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  5. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  6. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  7. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  8. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  9. A Proposal of New Spherical Particle Modeling Method Based on Stochastic Sampling of Particle Locations in Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Hyun; Kim, Do Hyun; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of); Noh, Jea Man [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    To the high computational efficiency and user convenience, the implicit method had received attention; however, it is noted that the implicit method in the previous studies has low accuracy at high packing fraction. In this study, a new implicit method, which can be used at any packing fraction with high accuracy, is proposed. In this study, the implicit modeling method in the spherical particle distributed medium for using the MC simulation is proposed. A new concept in the spherical particle sampling was developed to solve the problems in the previous implicit methods. The sampling method was verified by simulating the sampling method in the infinite and finite medium. The results show that the particle implicit modeling with the proposed method was accurately performed in all packing fraction boundaries. It is expected that the proposed method can be efficiently utilized for the spherical particle distributed mediums, which are the fusion reactor blanket, VHTR reactors, and shielding analysis.

  10. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  11. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  12. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  13. Pseudoprominent aorta: Radiographic findings and CT correlation

    International Nuclear Information System (INIS)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-01-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented

  14. Inferior hilar window on lateral chest radiographs

    International Nuclear Information System (INIS)

    Park, C.K.; Webb, W.R.; Klein, J.S.

    1990-01-01

    This paper determines the accuracy of lateral chest radiography in the detection of masses in the inferior hilar window, a normally avascular hilar region anterior to the lower lobe bronchi. Fifty patients with normal thoracic CT scans and 25 with hilar masses/adenopathy were selected retrospectively. The 75 corresponding lateral chest radiographs were blindly evaluated for visibility of the anterior walls of the lower lobe bronchi and the presence and laterality of abnormal soft tissue (>1 cm) in the inferior hilar window. Only a 7 x 7-cm square of the lateral radiograph was viewed

  15. Pelvic radiograph in skeletal dysplasias: An approach

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2017-01-01

    Full Text Available The bony pelvis is constituted by the ilium, ischium, pubis, and sacrum. The pelvic radiograph is an important component of the skeletal survey performed in suspected skeletal dysplasia. Most of the common skeletal dysplasias have either minor or major radiological abnormalities; hence, knowledge of the normal radiological appearance of bony pelvis is vital for recognizing the early signs of various skeletal dysplasias. This article discusses many common and some uncommon radiological findings on pelvic radiographs along with the specific dysplasia in which they are seen; common differential diagnostic considerations are also discussed.

  16. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  17. Cardiac and pericardial calcifications on chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, E.C., E-mail: ecferguson@hotmail.co [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States); Berkowitz, E.A. [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States)

    2010-09-15

    Many types of cardiac and pericardial calcifications identified on chest radiographs can be recognized and distinguished based on characteristic locations and appearances. The purpose of this review is to emphasize the importance of detecting cardiac and pericardial calcifications on chest radiographs, and to illustrate and describe the various types of calcifications that may be encountered and how they may be differentiated from one another. Each type of cardiac and pericardial calcification is discussed, its location and appearance described, and its significance explained. Recognizing and understanding these calcifications is important as they are often encountered in daily practice and play an important role in patient care.

  18. Pattern of scattered exposure from portable radiographs

    International Nuclear Information System (INIS)

    North, D.

    1985-01-01

    Concern periodically arises among the nursing and medical staffs of the institution's intensive care unit regarding their occupational exposure to radiation from the many radiographs taken in the unit. The patients are located in open areas or within individual cubicles whose walls are relatively thin and not shielded. To form a data base for educating the nursing/medical staffs and the technologists, the intensity and distribution of scattered exposure from actual radiographs of patients were measured. Comparison was also made with a simple phantom experiment in which the variables could be more precisely controlled

  19. Diagnosis of calcification on abdominal radiographs

    International Nuclear Information System (INIS)

    Lamb, C.R.; Kleine, L.J.; McMillan, M.C.

    1991-01-01

    A wide variety of normal and pathologic factors may induce intraabdominal calcification. In general, the most reliable indication of the cause of a calcification is its location; therefore, if the affected organ can be identified the radiographic diagnosis is often straightforward or, at least, limited to relatively few possibilities. With this principle in mind, a series of patients with abdominal calcification are described for the purpose of illustrating the appearance of calcification of various abdominal organs. In addition, etiology for the calcification in each patient is discussed. Certain extraabdominal calcifications which may be seen on abdominal radiographs are also mentioned

  20. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  1. Evaluation of contrast in duplicated radiographs

    International Nuclear Information System (INIS)

    Thunthy, K.H.; Weinberg, R.

    1982-01-01

    This investigation evaluated changes in the contrast of duplicated radiographs made at different ultraviolet light exposures. Increasing ultraviolet light exposure had different effects on the duplicates of originals of different background densities. When correctly exposed, a duplicate radiograph enhanced contrast. When originals had the same contrast but different background densities, their duplicates did not have the same contrast. It was not possible to duplicate accurately all the different contrasts measured on an original. It was possible, however, to produce duplicates with all contrasts greater than those of the original

  2. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  3. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    Davis, Michaela; Reeves, Pauline

    2006-01-01

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  4. Proposal for Classifying the Severity of Speech Disorder Using a Fuzzy Model in Accordance with the Implicational Model of Feature Complexity

    Science.gov (United States)

    Brancalioni, Ana Rita; Magnago, Karine Faverzani; Keske-Soares, Marcia

    2012-01-01

    The objective of this study is to create a new proposal for classifying the severity of speech disorders using a fuzzy model in accordance with a linguistic model that represents the speech acquisition of Brazilian Portuguese. The fuzzy linguistic model was run in the MATLAB software fuzzy toolbox from a set of fuzzy rules, and it encompassed…

  5. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  6. Radiographers' commitment to continuing professional development: A single-centre evaluation

    International Nuclear Information System (INIS)

    Stevens, Barry J.

    2016-01-01

    Purpose: This study aimed to examine radiographers' commitment to continuing professional development (CPD), and to ascertain what types of activities are preferred so a model for provision of departmental activities could be developed. Methods: An online survey was used to obtain information from all departmental radiographers regarding their commitment to CPD. Statistical analysis, using Spearman's Rho and Chi-Square test, was utilised to investigate any associations. Results: All radiographers (n = 57) were invited via email. A response rate of 67% (n = 38) prevailed. Radiographers feel CPD is important and a positive correlation existed with feelings regarding compulsory CPD (r value = .718, P value = .001). Thirty-four percent had logged the SOR-recommended twelve or more pieces of CPD in the last 2 years. One to three hours a month is the preferred amount of own time radiographers are willing to dedicate. Negative correlations exist between the amount of own time radiographers are willing to commit to CPD activities and their feelings regarding compulsory CPD (r value = −.419, P value = .009), and HCPC audit (r value = −.509, P value .001). Conclusion: Although radiographers recognise the importance of CPD many spend less than four hours of their own time a month on CPD. Departmental activities should be free, short lasting, lunchtime presentations with theory presentation that encourage interaction and discussion with inclusion of practical elements. Further research investigating the barriers that prevent radiographers from partaking in CPD and the causes for insufficient CPD records is recommended. - Highlights: • The large majority of radiographers feel CPD is important or very important to them. • The majority had positive opinions regarding compulsory CPD and HCPC audit. • 50% of radiographers commit less than 4 h of their own time to CPD. • As radiographers get older they log less CPD and commit less time to CPD.

  7. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  8. Emerging identities: A proposed model for an interactive science curriculum for First Nations students

    Science.gov (United States)

    Sable, Trudy

    Mi'kmaw students face a complexity of personal, cultural, and social conditions within contemporary educational systems that affect their continued participation in the educational process offered within Atlantic Canada. Despite a variety of approaches developed by educators to address the high drop out rate and lack of interest in science, the statistics remain largely unchanged. Aboriginal educators are calling for a "new story" in education that better meets the needs of Aboriginal students. This study attempts to identify the conditions and contexts necessary to bridge the gap that currently exists for Aboriginal students in science studies. The research investigates the basic relationship between learning in general and the meaning-making processes engaged in by students of a Grade 7/8 class within a Mi'kmaw reserve school. It leads to a proposal for an alternative pedagogy, or a new narrative, for teaching science to Aboriginal students and the foundations for a culturally interactive science curriculum. For educators to understand the complexity of issues affecting Mi'kmaw student achievement in science requires a theoretical framework that allows the students' lived experience to emerge. Toward this end, the research includes both phenomenological and ethnographic approaches to understanding the lived experiences and cultural narratives based on interviews with the students, a field trip within the community, and a trial chemistry lesson. I examined how these students perceive themselves in different contexts and how their sense of identity establishes the meaningfulness of particular educational content. I also assessed how person, community/cultural and social contexts affect the students' learning. Part of creating this new narrative requires recognizing knowledge, including science, as a cultural product Taking this cultural view of scientific knowledge allows us to view learning as a process of identity formation and culture as a system of symbols

  9. Ergonomic strategies to improve radiographers' posture during mammography activities.

    Science.gov (United States)

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  10. Comparison of radiographic technique by computer simulation

    International Nuclear Information System (INIS)

    Brochi, M.A.C.; Ghilardi Neto, T.

    1989-01-01

    A computational algorithm to compare radiographic techniques (KVp, mAs and filters) is developed based in the fixation of parameters that defines the images, such as optical density and constrast. Before the experience, the results were used in a radiography of thorax. (author) [pt

  11. 21 CFR 1020.31 - Radiographic equipment.

    Science.gov (United States)

    2010-04-01

    ...) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING PRODUCTS § 1020.31 Radiographic... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... exposure of greater than one-half second. Except during panoramic dental radiography, termination of...

  12. Radiographic contrast media, function and future reassessed

    International Nuclear Information System (INIS)

    Sovak, M.

    1988-01-01

    A brief review is given of the use of radiographic contrast media in cholecysto- and cholangiography, central nervous system imaging, urography and angiography. Other aspects briefly discussed are the use of large i.v. doses of contrast media for CT contrast enhancement and the design theory for improved water soluble contrast media. (U.K.)

  13. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  14. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  15. Unusual radiographic changes of a gout patient

    International Nuclear Information System (INIS)

    Markota, J.

    2004-01-01

    Background. Gout is a metabolic disorder that results in hyperuricemia and accumulation of uric acid crystals (urats) in tissues, especially joint cartilage. The gouty arthritis presents as acute attacks of arthritis leading eventually to chronic gouty arthritis. In 80% of cases it first occurs in the matatarsophalangeal (MTP) joint of the great toe and is more frequent in male population. Case report. We present a case of unusual radiographic changes accompanying gouty arthritis. A 63 year old female complained about swelling of the first MTP joint on the right, right knee, about stiffness of feet and hands' digits and about backache. First symptoms started to appear 30 years ago. In the time of examination radiographs displayed degenerative changes of the majority of presented joints, bilateral sacroiliitis and osseous ankylosis of both insteps. Microscopic examination showed urate crystals in the samples of the synovial fluid aspirated from the knee. The histological findings of the synovial tissue after the synovectomy were also in favour of gouty arthritis. Conclusions. Radiographs are the most important imaging modality in the diagnostic process of gout. However, radiographic differential diagnosis can be difficult, since the findings overlap with other conditions which cause arthritis and osteoarthritis especially in longstanding gout, elderly patients and females. The diagnosis must be often confirmed with the help of laboratory and histological findings. (author)

  16. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  17. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  18. Assessment of radiation protection practices among radiographers ...

    African Journals Online (AJOL)

    Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Conclusion: Radiographers within Lagos metropolis showed an excellent knowledge of ...

  19. Chest radiographic findings in Human Immunodeficiency Virus ...

    African Journals Online (AJOL)

    This study was carried out to determine findings on chest radiographs in HIV positive/AIDS patients at the University of Benin Teaching Hospital (UBTH) Benin City. All consecutive HIV positive/AIDS patients, managed at the UBTH between 1991 and 2001 were included in the study. Patients had postero-anterior (PA) chest ...

  20. Thoracic radiographic anatomy in goats | Makungu | Tanzania ...

    African Journals Online (AJOL)

    The aim of this study was to describe the normal radiographic anatomy of the thorax of small East African goats as a reference for clinical use. Radiography of the thorax was performed under general anaesthesia in 10 healthy small East African goats. Right lateral (RL), left lateral (LL), dorsoventral (DV) and ventrodorsal ...

  1. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  2. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  3. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  4. Correlation Of Radiographic Patterns Of Pulmonary Tuberculosis ...

    African Journals Online (AJOL)

    Patients with higher CD4+ counts often present in \\"classic\\" fashion (upper zone infiltrates cavities) whereas those with low CD4+ counts are more likely to present atypically. The chest radiographic appearances of HIV-seropositive patients presenting with pulmonary tuberculosis (PTB) are diverse, creating difficulty in ...

  5. Effects of rotation radiographic dimensions of metacarpals

    International Nuclear Information System (INIS)

    Armes, F.M.; Horsman, A.; Bentley, H.B.

    1979-01-01

    An experiment is described which shows that small rotations of metacarpals about their long axis produce small systematic changes in the cortical dimensions as measured by radiographic morphometry. The effect is of no significance in cross-sectional studies but is an important source of error in sequential studies. (author)

  6. Development-based Trust: Proposing and Validating a New Trust Measurement Model for Buyer-Seller Relationships

    Directory of Open Access Journals (Sweden)

    José Mauro da Costa Hernandez

    2010-04-01

    Full Text Available This study proposes and validates a trust measurement model for buyer-seller relationships. Baptized as development-based trust, the model encompasses three dimensions of trust: calculus-based, knowledge-based and identification-based. In addition to recognizing that trust is a multidimensional construct, the model also assumes that trust can evolve to take on a different character depending on the stage of the relationship. In order to test the proposed model and compare it to the characteristic-based trust measurement model, the measure most frequently used in the buyer-seller relationship literature, data were collected from 238 clients of an IT product wholesaler. The results show that the scales are valid and reliable and the proposed development-based trust measurement model is superior to the characteristic-based trust measurement model in terms of its ability to explain certain variables of interest in buyer-seller relationships (long-term relationship orientation, information sharing, behavioral loyalty and future intentions. Implications for practice, limitations and suggestions for future studies are discussed.

  7. Study on a model for future occupational health: proposal for an occupational health service model in Japan.

    Science.gov (United States)

    Higashi, Toshiaki

    2006-10-01

    The Study Model for Future Occupational Health (funded by a research grant from the Ministry of Health, Welfare and Labor) is a joint research project involving various organizations and agencies undertaken from 2002 to 2004. Society has undergone a dramatic transformation due to technological developments and internationalization. At the same time a low birth rate and an aging population have resulted in an increase in both the percentage of workers experiencing strong anxiety and stress in relation to their jobs and the working environment and the number of suicides. As a natural consequence, occupational health services are now expected to provide EAP, consulting and other functions that were formerly considered outside the realm of occupational health. In consideration of this background, the present study propose the following issues to provide a model for future occupational health services that meet the conditions presently confronted by each worker. 1. How to provide occupational health services and occupational physicians' services: 1) a basic time of 20 minutes of occupational health services per year should be allotted to each worker and to all workers; 2) the obligatory regulations should be revised to expand the obligation from businesses each with 50 or more employees under the present laws to businesses each with 30 or more employees. 2. Providers of occupational health services and occupational physicians' services: (1) reinforcement of outside occupational health agencies; (2) fostering occupational health consultant firms; (3) development of an institute of occupational safety and health; (4) support of activities by authorized occupational physicians in the field; (5) expanding of joint selection of occupational physicians including subsidy increase and the extension of a period of subsidy to five hears; (6) licensing of new entry into occupational health undertaking. 3. Introduction of new report system: (1) establishment of the obligation to

  8. Sensitivity and specificity of plain radiographic features of peripheral enthesopathy at major sites in psoriatic arthritis

    International Nuclear Information System (INIS)

    Helliwell, P.S.; Porter, G.

    2007-01-01

    It has been proposed that the defining difference between rheumatoid arthritis and spondyloarthropathy (including psoriatic arthritis) is the initial pathological lesion where the emphasis in psoriatic arthritis is on the enthesis and in rheumatoid arthritis on the synovium. Classical radiological descriptions of seronegative spondyloarthropathy include enthesopathy at major entheseal insertions characterised by erosions and exuberant new bone formation. In this study, the plain radiographic features of spondyloarthropathy are compared between psoriatic arthritis, other spondyloarthropathies and rheumatoid arthritis. The CASPAR study collected clinical, radiological and laboratory data on 588 patients with physician diagnosed psoriatic arthritis and 525 controls with other inflammatory arthritis, 70% of which had rheumatoid arthritis. Plain radiographs of the pelvis and heels were part of the study protocol, although radiographs of other potential entheseal sites such as the knee, elbow and shoulder, were interpreted if available. All radiographs were read blind by two observers working in tandem. Significant differences in entheseal erosion and entheseal new bone formation were found between psoriatic arthritis, ankylosing spondylitis, undifferentiated spondyloarthropathy, rheumatoid arthritis and other diagnoses (entheseal erosion, chi-squared 20.8, p = 0.008; entheseal new bone formation, chi-squared 24.5, p = 0.001). These differences were mainly due to a higher proportion of these features in ankylosing spondylitis. No differences in the plain radiographic features of enthesopathy were found between psoriatic arthritis and rheumatoid arthritis except in the case of entheseal new bone formation at sites of attachment of inguinal ligament, sartorius and rectus femoris muscles to the ilium (OR 3.01, 95% CI 1.13-8.02). Very few subjects with symptomatic heel involvement had radiographic changes and minimal differences were found between those with and without

  9. Sensitivity and specificity of plain radiographic features of peripheral enthesopathy at major sites in psoriatic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Helliwell, P.S. [University of Leeds, Academic Unit of Musculoskeletal and Rehabilitation Medicine, Leeds (United Kingdom); Porter, G. [Airedale Hospital NHS Trust, Keighley, West Yorkshire (United Kingdom)

    2007-11-15

    It has been proposed that the defining difference between rheumatoid arthritis and spondyloarthropathy (including psoriatic arthritis) is the initial pathological lesion where the emphasis in psoriatic arthritis is on the enthesis and in rheumatoid arthritis on the synovium. Classical radiological descriptions of seronegative spondyloarthropathy include enthesopathy at major entheseal insertions characterised by erosions and exuberant new bone formation. In this study, the plain radiographic features of spondyloarthropathy are compared between psoriatic arthritis, other spondyloarthropathies and rheumatoid arthritis. The CASPAR study collected clinical, radiological and laboratory data on 588 patients with physician diagnosed psoriatic arthritis and 525 controls with other inflammatory arthritis, 70% of which had rheumatoid arthritis. Plain radiographs of the pelvis and heels were part of the study protocol, although radiographs of other potential entheseal sites such as the knee, elbow and shoulder, were interpreted if available. All radiographs were read blind by two observers working in tandem. Significant differences in entheseal erosion and entheseal new bone formation were found between psoriatic arthritis, ankylosing spondylitis, undifferentiated spondyloarthropathy, rheumatoid arthritis and other diagnoses (entheseal erosion, chi-squared 20.8, p = 0.008; entheseal new bone formation, chi-squared 24.5, p = 0.001). These differences were mainly due to a higher proportion of these features in ankylosing spondylitis. No differences in the plain radiographic features of enthesopathy were found between psoriatic arthritis and rheumatoid arthritis except in the case of entheseal new bone formation at sites of attachment of inguinal ligament, sartorius and rectus femoris muscles to the ilium (OR 3.01, 95% CI 1.13-8.02). Very few subjects with symptomatic heel involvement had radiographic changes and minimal differences were found between those with and without

  10. Image rejects/retakes--radiographic challenges.

    Science.gov (United States)

    Waaler, D; Hofmann, B

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5 %. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter-subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted.

  11. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    Waaler, D.; Hofmann, B.

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  12. In Pursuit of Social Betterment: A Proposal to Evaluate the Da Vinci Learning Model

    Science.gov (United States)

    Henry, Gary T.

    2005-01-01

    The author presents a proposal that is roughly based on a contingency-based theory of evaluation developed in his book, "Evaluation: An Integrated Framework for Understanding, Guiding, and Improving Policies and Programs" (Mark, Henry, and Julnes, 2000). He and his coauthors stated in this book that social betterment was the ultimate goal of…

  13. Absenteeism in Undergraduate Business Education: A Proposed Model and Exploratory Investigation

    Science.gov (United States)

    Burke, Lisa A.

    2010-01-01

    One issue in undergraduate business education remaining underexamined is student absenteeism. In this article, the literature on undergraduate absenteeism is reviewed culminating in a proposed conceptual framework to guide future research, and an exploratory investigation of management students' attitudes about absenteeism is conducted.…

  14. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle

    2012-01-01

    and to find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years......Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs...... the length from the ramus to the incisors (olr-id) showed a statistically significant correlation. By combining this length with the mesiodistal width of the lower second molar, the prediction of eruption of the lower third molar was strengthened. A new formula for calculating the probability of eruption...

  15. Occupational kneeling and radiographic tibiofemoral and patellofemoral osteoarthritis

    DEFF Research Database (Denmark)

    Rytter, Søren; Egund, Niels; Jensen, Lilli Kirkeskov

    2009-01-01

    ABSTRACT: BACKGROUND: The objective of our study was to evaluate the association between occupational kneeling and compartment specific radiographic tibiofemoral (TF) and patellofemoral (PF) osteoarthritis (OA). METHODS: Questionnaire data and bilateral knee radiographs were obtained in 134 male...

  16. Recognizing the radiographic features of some common bovine foot problems

    International Nuclear Information System (INIS)

    Ebeid, M.; Steiner, A.

    1996-01-01

    Radiographs of an injured or infected bovine foot can be tricky to interpret - the anatomy is complex, and the signs may be subtle. This guide leads you through the classic radiographic features of several common foot conditions

  17. Proposed Robot Scheme with 5 DoF and Dynamic Modelling Using Maple Software

    Directory of Open Access Journals (Sweden)

    Shala Ahmet

    2017-11-01

    Full Text Available In this paper is represented Dynamical Modelling of robots which is commonly first important step of Modelling, Analysis and Control of robotic systems. This paper is focused on using Denavit-Hartenberg (DH convention for kinematics and Newton-Euler Formulations for dynamic modelling of 5 DoF - Degree of Freedom of 3D robot. The process of deriving of dynamical model is done using Software Maple. Derived Dynamical Model of 5 DoF robot is converted for Matlab use for future analysis, control and simulations.

  18. Proposed Model for a Streamlined, Cohesive, and Optimized K-12 STEM Curriculum with a Focus on Engineering

    Science.gov (United States)

    Locke, Edward

    2009-01-01

    This article presents a proposed model for a clear description of K-12 age-possible engineering knowledge content, in terms of the selection of analytic principles and predictive skills for various grades, based on the mastery of mathematics and science pre-requisites, as mandated by national or state performance standards; and a streamlined,…

  19. An analysis of a three-factor model proposed by the Danish Society of Actuaries for forecasting and risk analysis

    DEFF Research Database (Denmark)

    Jørgensen, Peter Løchte; Slipsager, Søren Kærgaard

    2016-01-01

    This paper provides the explicit solution to the three-factor diffusion model recently proposed by the Danish Society of Actuaries to the Danish industry of life insurance and pensions. The solution is obtained by use of the known general solution to multidimensional linear stochastic differential...

  20. Numerical Differentiation Methods for Computing Error Covariance Matrices in Item Response Theory Modeling: An Evaluation and a New Proposal

    Science.gov (United States)

    Tian, Wei; Cai, Li; Thissen, David; Xin, Tao

    2013-01-01

    In item response theory (IRT) modeling, the item parameter error covariance matrix plays a critical role in statistical inference procedures. When item parameters are estimated using the EM algorithm, the parameter error covariance matrix is not an automatic by-product of item calibration. Cai proposed the use of Supplemented EM algorithm for…

  1. New proposal of moderator temperature coefficient estimation method using gray-box model in NPP, (1)

    International Nuclear Information System (INIS)

    Mori, Michitsugu; Kagami, Yuichi; Kanemoto, Shigeru; Enomoto, Mitsuhiro; Tamaoki, Tetsuo; Kawamura, Shinichiro

    2004-01-01

    The purpose of the present paper is to establish a new void reactivity coefficient (VRC) estimation method based on gray box modeling concept. The gray box model consists of a point kinetics model as the first principle model and a fitting model of moderator temperature kinetics. Applying Kalman filter and maximum likehood estimation algorithms to the gray box model, MTC can be estimated. The verification test is done by Monte Carlo simulation, and, it is shown that the present method gives the best estimation results comparing with the conventional methods from the viewpoints of non-biased and smallest scattering estimation performance. Furthermore, the method is verified via real plant data analysis. The reason of good performance of the present method is explained by proper definition of likelihood function based on explicit expression of observation and system noise in the gray box model. (author)

  2. Observer performance in detecting multiple radiographic signals: prediction and analysis using a generalized ROC approach

    International Nuclear Information System (INIS)

    Metz, C.E.; Starr, S.J.; Lusted, L.B.

    1975-01-01

    The theories of decision processes and signal detection provide a framework for the evaluation of observer performance. Some radiologic procedures involve a search for multiple similar lesions, as in gallstone or pneumoconiosis examinations. A model is presented which attempts to predict, from the conventional receiver operating characteristic (ROC) curve describing the detectability of a single visual signal in a radiograph, observer performance in an experiment requiring detection of more than one such signal. An experiment is described which tests the validity of this model for the case of detecting the presence of zero, one, or two low-contrast radiographic images of a two-mm.-diameter lucite bead embedded in radiographic mottle. Results from six observers, including three radiologists, confirm the validity of the model and suggest that human observer performance for relatively complex detection tasks can be predicted from the results of simpler experiments

  3. Acute chest syndrome of sickle cell disease: radiographic and clinical analysis of 70 cases

    International Nuclear Information System (INIS)

    Martin, L.; Buonomo, C.

    1997-01-01

    Background. Acute chest syndrome (ACS) is a pulmonary illness with fever, chest pain, leukocytosis and new pulmonary opacity in a patient with sickle cell disease. It is a common reason for hospitalization in sickle cell patients, and a significant cause of mortality. The etiology of ACS is unclear. Lung or bone infarction and infection, among other possible causes, have been proposed. Objective. We reviewed the chest radiographs and medical records of 41 patients with 70 episodes of ACS and correlated the clinical and radiographic courses in an attempt to better characterize and understand the syndrome. Results. In 87 % of episodes, no identifiable etiology of ACS was found. This group of patients had a median age of 14 years and showed dramatic clinical and radiographic improvement within 24 h of therapy. In the remainder of episodes (13 %), an identifiable etiology was found, usually bacterial pneumonia. These patients were younger than the group without an identifiable etiology (median age 2 years) and had a prolonged radiographic course of illness. Conclusion. The chest radiographs of children with ACS without an identifiable etiology have an extremely typical appearance and evolution. Only in cases which do not have this typical pattern should infection be suspected as the underlying cause. (orig.). With 3 figs

  4. Incidence of Radiographic Cystic Lesions Associated With Unerupted Teeth in Dogs.

    Science.gov (United States)

    Babbitt, Sam G; Krakowski Volker, Mary; Luskin, Ira R

    2016-12-01

    Medical records and radiographs were retrospectively reviewed over a 3-year period (2012-2015) from dogs presented to a private dental referral practice. Medical records were evaluated for the diagnosis of impacted or embedded teeth. The identified dogs' radiographs were reviewed for the presence of radiographically significant cystic lesions that were associated with the impacted or embedded teeth. Radiographic criteria were established by the authors for the purposes of identifying cystic lesions in dogs of different breeds and sizes, using established indices from human dental pathology as a basis. When histopathology results were available, they were reviewed and reported. In this study, 136 dogs ranging in age from 3 months to 17 years were diagnosed with 213 unerupted teeth during the study period. There were 62 (29.1%) of the 213 radiographically apparent cystic lesions identified based on the criteria proposed in this study. In this study, 146 (68.5%) of the 213 unerupted teeth were identified as mandibular first premolar teeth. Histopathology was obtained on 28 (45.1%) of the 62 diagnosed cystic lesions. Dentigerous cysts accounted for 20 (71.4%) of the 28 cystic lesions. Brachycephalic breeds were overrepresented in this study. Boxer, pug, Shih Tzu, and Boston terrier dogs were most likely to present with cystic lesions associated with unerupted teeth. Seventeen (85%) of the 20 cases with a histopathologic diagnosis of dentigerous cyst were found within these 4 brachycephalic breeds.

  5. Radiographers' professional knowledge regarding parameters and safety issues in plain radiography: a questionnaire survey.

    Science.gov (United States)

    Farajollahi, A R; Fouladi, D F; Ghojazadeh, M; Movafaghi, A

    2014-08-01

    To review the knowledge of radiographers and examine the possible sociodemographic and situational contributors to this knowledge. A questionnaire survey was devised and distributed to a cohort of 120 radiographers. Each questionnaire contained two sections. In the first section, background data, including sex, age, highest academic level, grade point average (GPA), length of time from graduation, work experience as a radiographer and the status of previous refresher course(s), were collected. The second section contained 17 multiple-choice questions concerning radiographic imaging parameters and safety issues. The response rate was 63.8%. In univariate analytic model, higher academic degree (p workplace (p = 0.04) and taking previous refresher course(s) (p = 0.01) were significantly associated with higher knowledge score. In multivariate analytic model, however, higher academic degree (B = 1.62; p = 0.01), higher GPA (B = 0.50; p = 0.01) and taking previous refresher course(s) (B = -1.26; p = 0.03) were independently associated with higher level of knowledge. Age, sex, length of time from graduation and work experience were not associated with the respondents' knowledge score. Academic background is a robust indicator of a radiographer's professional knowledge. Refresher courses and regular knowledge assessments are highly recommended. This is the first study in the literature that examines professional knowledge of radiographers in terms of technical and safety issues in plain radiography. Academic degree, GPA and refresher courses are independent predictors of this knowledge. Regular radiographer professional knowledge checks may be recommended.

  6. Collaborative Proposal: Transforming How Climate System Models are Used: A Global, Multi-Resolution Approach

    Energy Technology Data Exchange (ETDEWEB)

    Estep, Donald

    2013-04-15

    Despite the great interest in regional modeling for both weather and climate applications, regional modeling is not yet at the stage that it can be used routinely and effectively for climate modeling of the ocean. The overarching goal of this project is to transform how climate models are used by developing and implementing a robust, efficient, and accurate global approach to regional ocean modeling. To achieve this goal, we will use theoretical and computational means to resolve several basic modeling and algorithmic issues. The first task is to develop techniques for transitioning between parameterized and high-fidelity regional ocean models as the discretization grid transitions from coarse to fine regions. The second task is to develop estimates for the error in scientifically relevant quantities of interest that provide a systematic way to automatically determine where refinement is needed in order to obtain accurate simulations of dynamic and tracer transport in regional ocean models. The third task is to develop efficient, accurate, and robust time-stepping schemes for variable spatial resolution discretizations used in regional ocean models of dynamics and tracer transport. The fourth task is to develop frequency-dependent eddy viscosity finite element and discontinuous Galerkin methods and study their performance and effectiveness for simulation of dynamics and tracer transport in regional ocean models. These four projects share common difficulties and will be approach using a common computational and mathematical toolbox. This is a multidisciplinary project involving faculty and postdocs from Colorado State University, Florida State University, and Penn State University along with scientists from Los Alamos National Laboratory. The completion of the tasks listed within the discussion of the four sub-projects will go a long way towards meeting our goal of developing superior regional ocean models that will transform how climate system models are used.

  7. The impact of preventive maintenance practices on manufacturing performance: A proposed model for SMEs in Malaysia

    Science.gov (United States)

    Lazim, Halim Mad; Taib, Che Azlan; Lamsali, Hendrik; Saleh, Mohamed Najib; Subramaniam, Chandrakantan

    2016-08-01

    Preventive maintenance (PM) plays important role to avoid or mitigate potential stoppages and disruptions of equipment or machinery from occurring in daily operations. PM emphasized total employee involvement and it is important for companies as well as Small and Medium Sized Enterprises (SMEs). SME sectors contribution to the Malaysian economy makes up 95% of the total manufacturers, however PM remain relatively lacking. The ability, reliability and effective maintenance management is highly important in order to achieve desired manufacturing performance. Therefore, organizational capability in planning, controlling, implementing and monitoring PM activities is important. Furthermore, empirical evidence on the potential impact of PM practices towards manufacturing performance with organizational capability as a moderating effect is still limited and indecisive. Henceforth, this paper aims to explore and investigate potential relationships between PM practices and manufacturing performance moderated by organizational capability in the contact of Malaysian SMEs in the manufacturing sector. Correspondently, the study intends to propose a new research framework and hypotheses to examine the abovementioned relationships. The proposed framework includes PM team, PM strategy and planned maintenance as the determinants, while organizational capability serves as the moderating variable. Manufacturing performance will be viewed in terms of innovation and financial factors. Proposed research direction and conclusion are discussed at the end of the study.

  8. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used to...

  9. Appearance of the mandibular incisive canal on panoramic radiographs

    NARCIS (Netherlands)

    Jacobs, R.; Mraiwa, N.; van Steenberghe, D.; Sanderink, G.C.H.; Quirynen, M.

    2004-01-01

    Panoramic radiographs are routinely used in the dental office for various diagnostic purposes. This study aimed to evaluate the visibility of neurovascular structures in the mandibular interforaminal region on such radiographs. Panoramic radiographs were obtained with a Cranex Tome (Soredex) from

  10. Assessment of the critical thinking skills of student radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Castle, Alan [University of Portsmouth, Centre for Radiography Education, St George' s Building, Portsmouth PO1 2HY (United Kingdom)]. E-mail: alan.castle@port.ac.uk

    2006-05-15

    Purpose: Enabling students to develop critical thinking skills is one of the key aims of higher education and in preparing student radiographers for the future, there are increasing demands on educators to teach critical thinking skills to facilitate reflective, evidence-based practice and inter-professional working. The aim of the paper is to attempt to compare students' self-perception of their critical thinking skills to their actual written assessment performance. Methods: Students were asked to self-report how they thought the course had developed their critical thinking skills and the outcomes of this exercise were compared to the scores of previous assessments that required the demonstration of these skills. Results: The results suggest that whilst students report having developed critical thinking skills during the course, the results of their written assessments requiring the demonstration of these skills all had a mean score of less than 60% which indicates (in terms of the university's grade criteria guidelines) 'little attempt to use critical discussion in their work.' Discussion: Thirteen components of critical thinking are proposed, together with ways in which they could be incorporated into a radiographic curriculum. Conclusions: It is suggested that educators may need to review the constructive alignment of their curricula and re-assess their teaching and assessment strategies in order to effectively develop students' critical thinking skills.

  11. Assessment of the critical thinking skills of student radiographers

    International Nuclear Information System (INIS)

    Castle, Alan

    2006-01-01

    Purpose: Enabling students to develop critical thinking skills is one of the key aims of higher education and in preparing student radiographers for the future, there are increasing demands on educators to teach critical thinking skills to facilitate reflective, evidence-based practice and inter-professional working. The aim of the paper is to attempt to compare students' self-perception of their critical thinking skills to their actual written assessment performance. Methods: Students were asked to self-report how they thought the course had developed their critical thinking skills and the outcomes of this exercise were compared to the scores of previous assessments that required the demonstration of these skills. Results: The results suggest that whilst students report having developed critical thinking skills during the course, the results of their written assessments requiring the demonstration of these skills all had a mean score of less than 60% which indicates (in terms of the university's grade criteria guidelines) 'little attempt to use critical discussion in their work.' Discussion: Thirteen components of critical thinking are proposed, together with ways in which they could be incorporated into a radiographic curriculum. Conclusions: It is suggested that educators may need to review the constructive alignment of their curricula and re-assess their teaching and assessment strategies in order to effectively develop students' critical thinking skills

  12. Merging of gamma radiographic and ultrasonic inspection data: bibliographical survey

    International Nuclear Information System (INIS)

    Gautier, S.

    1995-01-01

    This paper presents a number of experimental data processing notions with the aim of developing an NDT method based on merging ultrasonic and gamma radiographic data. We first review the industrial context concerned and, before moving on to specific data merging problems, we discuss the difficulties of reconstruction using only one type of data (radiographic or ultrasonic). The main part of the report begins with a brief reminder of gamma radiation and ultrasonic wave propagation principles. Certain imaging and reconstruction methods conventionally used for each type of measurement are also presented. Reconstruction problems are then directly approached in algebraic form. For the type of problem studied, the inspection data alone cannot lead to satisfactory reconstructions and we evidence the need to regulate the problem by introducing deductive information on the object to be reconstructed. The Bayes' approach provides a self-consistent means of integrating both the data information and the deductive information. It is based on probabilistic models of the variables involved, notably those of the object sought. We discuss at some length certain models of images used in gamma radiography (independent variable fields, variables having a Markov-type structure) and the Bernoulli-Gauss-type models used for ultrasonic trace deconvolution. Finally, we outline data merging paths. A formal Bayes' framework is used to present two merging approaches, after which we briefly describe our projects for the processing of already available experimental data. (author)

  13. Proposal for a Graded Authorisation Model for the Use of Ionising Radiation in Ireland

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-10-15

    The Radiological Protection Institute of Ireland RPII intends to refocus, streamline and modernise its regulation of the use of ionising radiation in Ireland. This report provides detailed proposals for establishing a graded approach to authorisation in which regulators will be able to focus on higher risk practices by simplifying requirements placed on those of lower risk, without compromising the safety or security of the Irish population. These proposals build on RPII strategic analyses that seek to navigate a course between the competing pressures of public sector reform and the rapid technological changes in medical and nuclear arenas, which challenge the licensing and advisory functions of RPII. A graded approach to authorisation provides the potential for a sustainable basis for future regulation in Ireland. Such an approach would be in line with the forthcoming EURATOM Basic Safety Standards and with general current regulatory trends, which are moving away from one-size-fits-all approaches towards more adaptive, interactive and transparent regulation. In seeking this reform, the RPII also aims to fully utilize the benefits of the internet and electronic communications and to improve the transparency of its processes. These proposals have been developed using a robust, comprehensive project methodology involving a root and branch analysis of current and potential future approaches to authorisation. A series of facilitated workshops were held, punctuated by intensive periods of focused co-enquiry, involving all members of the RPII Regulatory Service. This approach made the fullest use of the decades of expertise and knowledge of these staff. It also provided the platform for developing a common vision of a graded approach to authorisation; for agreeing the criteria for differentiating between levels of authorisation; for collecting the necessary evidence for decision-making and for identifying the implications of these decisions. The graded approach presented

  14. Proposal for a Graded Authorisation Model for the Use of Ionising Radiation in Ireland

    International Nuclear Information System (INIS)

    2012-10-01

    The Radiological Protection Institute of Ireland RPII intends to refocus, streamline and modernise its regulation of the use of ionising radiation in Ireland. This report provides detailed proposals for establishing a graded approach to authorisation in which regulators will be able to focus on higher risk practices by simplifying requirements placed on those of lower risk, without compromising the safety or security of the Irish population. These proposals build on RPII strategic analyses that seek to navigate a course between the competing pressures of public sector reform and the rapid technological changes in medical and nuclear arenas, which challenge the licensing and advisory functions of RPII. A graded approach to authorisation provides the potential for a sustainable basis for future regulation in Ireland. Such an approach would be in line with the forthcoming EURATOM Basic Safety Standards and with general current regulatory trends, which are moving away from one-size-fits-all approaches towards more adaptive, interactive and transparent regulation. In seeking this reform, the RPII also aims to fully utilize the benefits of the internet and electronic communications and to improve the transparency of its processes. These proposals have been developed using a robust, comprehensive project methodology involving a root and branch analysis of current and potential future approaches to authorisation. A series of facilitated workshops were held, punctuated by intensive periods of focused co-enquiry, involving all members of the RPII Regulatory Service. This approach made the fullest use of the decades of expertise and knowledge of these staff. It also provided the platform for developing a common vision of a graded approach to authorisation; for agreeing the criteria for differentiating between levels of authorisation; for collecting the necessary evidence for decision-making and for identifying the implications of these decisions. The graded approach presented

  15. Optimization of number and signal to noise ratio radiographs for defects 3D reconstruction in industrial control

    International Nuclear Information System (INIS)

    Bruandet, J.-P.

    2001-01-01

    Among numerous techniques for non-destructive evaluation (NOE), X-rays systems are well suited to inspect inner objects. Acquiring several radiographs of inspected objects under different points of view enables to recover a three dimensional structural information. In this NOE application, a tomographic testing is considered. This work deals with two tomographic testing optimizations in order to improve the characterization of defects that may occur into metallic welds. The first one consists in the optimization of the acquisition strategy. Because tomographic testing is made on-line, the total duration for image acquisition is fixed, limiting the number of available views. Hence, for a given acquisition duration, it is possible either to acquire a very limited number of radiographs with a good signal to noise ratio in each single acquisition or a larger number of radiographs with a limited signal to noise ratio. The second one consists in optimizing the 3D reconstruction algorithms from a limited number of cone-beam projections. To manage the lack of data, we first used algebraic reconstruction algorithms such as ART or regularized ICM. In terms of acquisition strategy optimization, an increase of the number of projections was proved to be valuable. Taking into account specific prior knowledge such as support constraint or physical noise model in attenuation images also improved reconstruction quality. Then, a new regularized region based reconstruction approach was developed. Defects to reconstruct are binary (lack of material in a homogeneous object). As a consequence, they are entirely described by their shapes. Because the number of defects to recover is unknown and is totally arbitrary, a level set formulation allowing handling topological changes was used. Results obtained with a regularized level-set reconstruction algorithm are optimistic in the proposed context. (author) [fr

  16. Tourism Cluster Competitiveness and Sustainability: Proposal for a Systemic Model to Measure the Impact of Tourism on Local Development

    Directory of Open Access Journals (Sweden)

    Sieglinde Kindl da Cunha

    2005-07-01

    Full Text Available This article proposes a model to measure tourism cluster impact on local development with a view to assessing tourism cluster interaction, competitiveness and sustainability impacts on the economy, society and the environment. The theoretical basis for this model is founded on cluster concept and typology adapting and integrating the systemic competitiveness and sustainability concepts within economic, social, cultural, environmental and political dimensions. The proposed model shows a holistic, multidisciplinary and multi-sector view of local development brought back through a systemic approach to the concepts of competitiveness, social equity and sustainability. Its results make possible strategic guidance to agents responsible for public sector tourism policies, as well as the strategies for competitiveness, competition, cooperation and sustainability in private companies and institutions.

  17. Mathematical Modelling in Engineering: A Proposal to Introduce Linear Algebra Concepts

    Science.gov (United States)

    Cárcamo Bahamonde, Andrea; Gómez Urgelles, Joan; Fortuny Aymemí, Josep

    2016-01-01

    The modern dynamic world requires that basic science courses for engineering, including linear algebra, emphasise the development of mathematical abilities primarily associated with modelling and interpreting, which are not exclusively calculus abilities. Considering this, an instructional design was created based on mathematical modelling and…

  18. Inconsistency of Bayesian Inference for Misspecified Linear Models, and a Proposal for Repairing It

    NARCIS (Netherlands)

    Grünwald, P.; van Ommen, T.

    2017-01-01

    We empirically show that Bayesian inference can be inconsistent under misspecification in simple linear regression problems, both in a model averaging/selection and in a Bayesian ridge regression setting. We use the standard linear model, which assumes homoskedasticity, whereas the data are

  19. Inconsistency of Bayesian inference for misspecified linear models, and a proposal for repairing it

    NARCIS (Netherlands)

    P.D. Grünwald (Peter); T. van Ommen (Thijs)

    2017-01-01

    textabstractWe empirically show that Bayesian inference can be inconsistent under misspecification in simple linear regression problems, both in a model averaging/selection and in a Bayesian ridge regression setting. We use the standard linear model, which assumes homoskedasticity, whereas the data

  20. A Proposed Model of Retransformed Qualitative Data within a Mixed Methods Research Design

    Science.gov (United States)

    Palladino, John M.

    2009-01-01

    Most models of mixed methods research design provide equal emphasis of qualitative and quantitative data analyses and interpretation. Other models stress one method more than the other. The present article is a discourse about the investigator's decision to employ a mixed method design to examine special education teachers' advocacy and…