WorldWideScience

Sample records for mock circulatory system

  1. Real-Time ECG Simulation for Hybrid Mock Circulatory Loops.

    Science.gov (United States)

    Korn, Leonie; Rüschen, Daniel; Zander, Niklas; Leonhardt, Steffen; Walter, Marian

    2018-02-01

    Classically, mock circulatory loops only simulate mechanical properties of the circulation. To connect the hydraulic world with electrophysiology, we present a real-time electrical activity model of the heart and show how to integrate this model into a real-time mock loop simulation. The model incorporates a predefined conduction pathway and a simplified volume conductor to solve the bidomain equations and the forward problem of electrocardiography, resulting in a physiological simulation of the electrocardiogram (ECG) at arbitrary electrode positions. A complete physiological simulation of the heart's excitation would be too CPU intensive. Thus, in our model, complexity was reduced to allow real-time simulation of ECG-triggered medical systems in vitro; this decreases time and cost in the development process. Conversely, the presented model can still be adapted to various pathologies by locally changing the properties of the heart's conduction pathway. To simulate the ECG, the heart is divided into suitable areas, which are innervated by the hierarchically structured conduction system. To distinguish different cardiac regions, a segmentation of the heart was performed. In these regions, Prim's algorithm was applied to identify the directed minimal spanning trees for conduction orientation. Each node of the tree was assigned to a cardiac action potential generated by its hybrid automaton to represent the heart's conduction system by the spatial distribution of action potentials. To generate the ECG output, the bidomain equations were implemented and a simple model of the volume conductor of the body was used to solve the forward problem of electrocardiography. As a result, the model simulates potentials at arbitrary electrode positions in real-time. To verify the developed real-time ECG model, measurements were made within a hybrid mock circulatory loop, including a simple ECG-triggered ventricular assist device control. The model's potential value is to simulate

  2. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    Science.gov (United States)

    Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard

    2017-10-01

    Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  4. An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.

    Science.gov (United States)

    Tozzi, Piergiorgio; Maertens, Audrey; Emery, Jonathan; Joseph, Samuel; Kirsch, Matthias; Avellan, François

    2017-11-24

    We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population. The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured. At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%. The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.

  5. A Physical Heart Failure Simulation System Utilizing the Total Artificial Heart and Modified Donovan Mock Circulation.

    Science.gov (United States)

    Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Betterton, Edward; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J

    2017-07-01

    With the growth and diversity of mechanical circulatory support (MCS) systems entering clinical use, a need exists for a robust mock circulation system capable of reliably emulating and reproducing physiologic as well as pathophysiologic states for use in MCS training and inter-device comparison. We report on the development of such a platform utilizing the SynCardia Total Artificial Heart and a modified Donovan Mock Circulation System, capable of being driven at normal and reduced output. With this platform, clinically relevant heart failure hemodynamics could be reliably reproduced as evidenced by elevated left atrial pressure (+112%), reduced aortic flow (-12.6%), blunted Starling-like behavior, and increased afterload sensitivity when compared with normal function. Similarly, pressure-volume relationships demonstrated enhanced sensitivity to afterload and decreased Starling-like behavior in the heart failure model. Lastly, the platform was configured to allow the easy addition of a left ventricular assist device (HeartMate II at 9600 RPM), which upon insertion resulted in improvement of hemodynamics. The present configuration has the potential to serve as a viable system for training and research, aimed at fostering safe and effective MCS device use. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Structures with Reconfigurable Circulatory Systems

    National Research Council Canada - National Science Library

    Clark, William W; Beckman, Eric J; Cho, Sung K; Weiland, Lisa M; Bielawski, Christopher W

    2008-01-01

    .... One trait that many biological system have that conventional structures do not is a circulatory system, which can be used for many purposes, one of which is the transport of structural material...

  7. Hemocompatibility of Axial Versus Centrifugal Pump Technology in Mechanical Circulatory Support Devices.

    Science.gov (United States)

    Schibilsky, David; Lenglinger, Matthias; Avci-Adali, Meltem; Haller, Christoph; Walker, Tobias; Wendel, Hans Peter; Schlensak, Christian

    2015-08-01

    The hemocompatible properties of rotary blood pumps commonly used in mechanical circulatory support (MCS) are widely unknown regarding specific biocompatibility profiles of different pump technologies. Therefore, we analyzed the hemocompatibility indicating markers of an axial flow and a magnetically levitated centrifugal device within an in vitro mock loop. The HeartMate II (HM II; n = 3) device and a CentriMag (CM; n = 3) adult pump were investigated in a human whole blood mock loop for 360 min using the MCS devices as a driving component. Blood samples were analyzed by enzyme-linked immunosorbent assay for markers of coagulation, complement system, and inflammatory response. There was a time-dependent activation of the coagulation (thrombin-antithrombin complexes [TAT]), complement (SC5b-9), and inflammation system (polymorphonuclear [PMN] elastase) in both groups. The mean value of TAT (CM: 4.0 μg/L vs. 29.4 μg/L, P technologies and a magnetically levitated centrifugal pump design might be superior. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals Inc.

  8. Fixation and mounting of porcine aortic valves for use in mock circuits.

    Science.gov (United States)

    Schlöglhofer, Thomas; Aigner, Philipp; Stoiber, Martin; Schima, Heinrich

    2013-10-01

    Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits. Porcine aortic roots were obtained from the abattoir and used either in native condition or after fixation. Fixation was performed at a constant retrograde pressure to ensure closed valve position. Fixation time was 4 h in a 0.5%-glutaraldehyde phosphate buffer. The fixed valves were molded into a modular mock circulation connector using a fast curing silicone. Valve functionality was evaluated in a pulsatile setting (cardiac output = 4.7 l/min, heart rate = 80 beats/min) and compared before and after fixation. Leaflet motion was recorded with a high-speed camera and valve insufficiency was quantified by leakage flow under steady pressure application (80 mmHg). Under physiological conditions the aortic valves showed almost equal leaflet motion in native and fixed conditions. However, the leaflets of the native valves showed lower stiffness and more fluttering during systole than the fixed specimens. Under retrograde pressure, fresh and fixed valves showed small leakage flows of <30 ml/min. The new mounting and fixation procedure is a fast method to fabricate low cost biologic valves for the use in mock circuits.

  9. Mass Transport: Circulatory System with Emphasis on Nonendothermic Species.

    Science.gov (United States)

    Crossley, Dane A; Burggren, Warren W; Reiber, Carl L; Altimiras, Jordi; Rodnick, Kenneth J

    2016-12-06

    Mass transport can be generally defined as movement of material matter. The circulatory system then is a biological example given its role in the movement in transporting gases, nutrients, wastes, and chemical signals. Comparative physiology has a long history of providing new insights and advancing our understanding of circulatory mass transport across a wide array of circulatory systems. Here we focus on circulatory function of nonmodel species. Invertebrates possess diverse convection systems; that at the most complex generate pressures and perform at a level comparable to vertebrates. Many invertebrates actively modulate cardiovascular function using neuronal, neurohormonal, and skeletal muscle activity. In vertebrates, our understanding of cardiac morphology, cardiomyocyte function, and contractile protein regulation by Ca2+ highlights a high degree of conservation, but differences between species exist and are coupled to variable environments and body temperatures. Key regulators of vertebrate cardiac function and systemic blood pressure include the autonomic nervous system, hormones, and ventricular filling. Further chemical factors regulating cardiovascular function include adenosine, natriuretic peptides, arginine vasotocin, endothelin 1, bradykinin, histamine, nitric oxide, and hydrogen sulfide, to name but a few. Diverse vascular morphologies and the regulation of blood flow in the coronary and cerebral circulations are also apparent in nonmammalian species. Dynamic adjustments of cardiovascular function are associated with exercise on land, flying at high altitude, prolonged dives by marine mammals, and unique morphology, such as the giraffe. Future studies should address limits of gas exchange and convective transport, the evolution of high arterial pressure across diverse taxa, and the importance of the cardiovascular system adaptations to extreme environments. © 2017 American Physiological Society. Compr Physiol 7:17-66, 2017. Copyright © 2017 John

  10. Physiological characterization of the SynCardia total artificial heart in a mock circulation system.

    Science.gov (United States)

    Crosby, Jessica R; DeCook, Katrina J; Tran, Phat L; Smith, Richard G; Larson, Douglas F; Khalpey, Zain I; Burkhoff, Daniel; Slepian, Marvin J

    2015-01-01

    The SynCardia total artificial heart (TAH) has emerged as an effective, life-saving biventricular replacement system for a wide variety of patients with end-stage heart failure. Although the clinical performance of the TAH is established, modern physiological characterization, in terms of elastance behavior and pressure-volume (PV) characterization has not been defined. Herein, we examine the TAH in terms of elastance using a nonejecting left ventricle, and then characterize the PV relation of the TAH by varying preload and afterload parameters using a Donovan Mock Circulatory System. We demonstrate that the TAH does not operate with time-varying elastance, differing from the human heart. Furthermore, we show that the TAH has a PV relation behavior that also differs from that of the human heart. The TAH does exhibit Starling-like behavior, with output increasing via preload-dependent mechanisms, without reliance on an alteration of inotropic state within the operating window of the TAH. Within our testing range, the TAH is insensitive to variations in afterload; however, this insensitivity has a limit, the limit being the maximum driving pressure of the pneumatic driver. Understanding the physiology of the TAH affords insight into the functional parameters that govern artificial heart behavior providing perspective on differences compared with the human heart.

  11. An Integrated Simulation Tool for Modeling the Human Circulatory System

    Science.gov (United States)

    Asami, Ken'ichi; Kitamura, Tadashi

    This paper presents an integrated simulation of the circulatory system in physiological movement. The large circulatory system model includes principal organs and functional units in modules in which comprehensive physiological changes such as nerve reflexes, temperature regulation, acid/base balance, O2/CO2 balance, and exercise are simulated. A beat-by-beat heart model, in which the corresponding electrical circuit problems are solved by a numerical analytic method, enables calculation of pulsatile blood flow to the major organs. The integration of different perspectives on physiological changes makes this simulation model applicable for the microscopic evaluation of blood flow under various conditions in the human body.

  12. Measurement and control system for the ITER remote handling mock-up test

    International Nuclear Information System (INIS)

    Oka, K.; Kakudate, S.; Takiguchi, Y.; Ako, K.; Taguchi, K.; Tada, E.; Ozaki, F.; Shibanuma, K.

    1998-01-01

    The mock-up test platforms composed of full-scale remote handling (RH) equipment were developed for demonstrating remote replacement of the ITER blanket and divertor. In parallel, the measurement and control system for operating these RH equipment were constructed on the basis of open architecture with object oriented feature, aiming at realization of fully-remoted automatic operation required for ITER. This paper describes the design concept of the measurement and control system for the remote handling equipment of ITER, and outlines the measured performances of the fabricated measurement system for the remote handling mock-up tests, which includes Data Acquisition System (DAS), Visual Monitoring System (VMS) and Virtual Reality System (VRS). (authors)

  13. Biological evaluation of mechanical circulatory support systems in calves

    NARCIS (Netherlands)

    Rakhorst, G; VanDerMeer, J; Kik, C; Mihaylov, D; Havlik, P; Trinkl, J; Monties, [No Value

    Data from animal experiments with mechanical circulatory support systems (MCSS) performed in Groningen and Marseille over the past years were used to obtain normal values of hematological, coagulation, rheological and blood chemistry parameters in calves. These parameters were divided between two

  14. Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

    Science.gov (United States)

    Gallagher, R. R.

    1974-01-01

    The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

  15. Performance test results of mock-up test facility of HTTR hydrogen production system

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo

    2004-01-01

    For the purpose to demonstrate effectiveness of high-temperature nuclear heat utilization, Japan Atomic Energy Research Institute has been developing a hydrogen production system and has planned to connect the hydrogen production system to High Temperature Engineering Test Reactor (HTTR). Prior to construction of a HTTR hydrogen production system, a mock-up test facility was constructed to investigate transient behavior of the hydrogen production system and to establish system controllability. The Mock-up test facility with a full-scale reaction tube is an approximately 1/30-scale model of the HTTR hydrogen production system and an electric heater is used as a heat source instead of a reactor. After its construction, a performance test of the test facility was carried out in the same pressure and temperature conditions as those of the HTTR hydrogen production system to investigate its performance such as hydrogen production ability, controllability and so on. It was confirmed that hydrogen was stably produced with a hot helium gas about 120m 3 /h, which satisfy the design value, and thermal disturbance of helium gas during the start-up could be mitigated within the design value by using a steam generator. The mock-up test of the HTTR hydrogen production system using this facility will continue until 2004. (author)

  16. Vascular and Immunobiology of the Circulatory Sphingosine 1-Phosphate Gradient

    Science.gov (United States)

    Yanagida, Keisuke; Hla, Timothy

    2017-01-01

    Vertebrates are endowed with a closed circulatory system, the evolution of which required novel structural and regulatory changes. Furthermore, immune cell trafficking paradigms adapted to the barriers imposed by the closed circulatory system. How did such changes occur mechanistically? We propose that spatial compartmentalization of the lipid mediator sphingosine 1-phosphate (S1P) may be one such mechanism. In vertebrates, S1P is spatially compartmentalized in the blood and lymphatic circulation, thus comprising a sharp S1P gradient across the endothelial barrier. Circulatory S1P has critical roles in maturation and homeostasis of the vascular system as well as in immune cell trafficking. Physiological functions of S1P are tightly linked to shear stress, the key biophysical stimulus from blood flow. Thus, circulatory S1P confinement could be a primordial strategy of vertebrates in the development of a closed circulatory system. This review discusses the cellular and molecular basis of the S1P gradients and aims to interpret its physiological significance as a key feature of the closed circulatory system. PMID:27813829

  17. Siloette, Siloe mock-up

    International Nuclear Information System (INIS)

    Delcroix, V.; Jeanne, G.; Mitault, G.; Schulhof, P.

    1964-01-01

    Siloette is the Siloe mock-up. The main installations are described: various tanks, building, auxiliaries, control systems... Precis ions are given about precautions taken for using spent fuel elements. (authors) [fr

  18. Mocking in Oracle PL/SQL

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    Testing is not very popular in database development, so there are none common approaches how to test software written in database. Surprisingly one of the oldest DB still lacks of appropriate testing approach for its PL/SQL programs. SQLDeveloper's built-in test "framework" is far from excellence, especially it does not cover mocking which is inherent part of testing for any bigger system being developed. This talk will briefly introduce Edition-Based Redefinition by Oracle to be used for mocking.

  19. Diseases of the circulatory system and the likelihood of their development in the workforce at the Chernobyl nuclear power plant

    International Nuclear Information System (INIS)

    Khomazyuk, N.N.; Goncharenko, L.I.; Kovalev, A.C.; Nastina, E.M.; Chebanyuk, C.V.

    1995-01-01

    Large doses of general or localized radiation can provoke changes in the circulatory system, can affect all layers of the heart and cause selective damage to vascular endothelium. A study of the condition of the circulatory system in the victims of the Chernobyl disaster was carried out by the authors in 1986. This paper presents the results of an investigation into the condition of the circulatory system of Chernobyl employees working for long periods with sources of ionizing radiation. (O.L.). 11 refs., 3 figs

  20. From Head to Toe: Respiratory, Circulatory, and Skeletal Systems. Book 3.

    Science.gov (United States)

    Wiebe, Arthur, Ed.; And Others

    Designed to supplement curricular programs dealing with the human body, this booklet offers an activity-based, student-oriented approach for middle school teachers and students. Twelve activities focus on principles and skills related to the respiratory, circulatory, and skeletal systems. Each activity consists of student sheets and a teacher's…

  1. Developing seventh grade students' systems thinking skills in the context of the human circulatory system.

    Science.gov (United States)

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students' systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students' systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students' systems thinking components and examine possible changes in the students' knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students' ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems' components and its processes within a framework of relationships, namely the students' systems thinking skills were improved in the course of learning using the teaching and learning materials.

  2. Developing Seventh Grade Students’ Systems Thinking Skills in the Context of the Human Circulatory System

    Science.gov (United States)

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students’ systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students’ systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students’ systems thinking components and examine possible changes in the students’ knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students’ ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems’ components and its processes within a framework of relationships, namely the students’ systems thinking skills were improved in the course of learning using the teaching and learning materials. PMID:25520948

  3. Diseases of the circulatory system: health status and perspectives for changes

    Directory of Open Access Journals (Sweden)

    V. I. Klimenko

    2014-02-01

    Full Text Available During last 20 years rates of incidence and prevalence of diseases of the circulatory system in Ukraine have been growing from year to year and became problems of current interest. According to the program of WHO, realization of diseases prevention is provided by using of scientific justification and monitoring of health indexes, including diseases of the circulatory system. Goal of our research was to analyze health status of population of Zaporozhye region concerning cardiovascular diseases. Data since 1995 to 2012 y. were taken in the Center of medical statistics of Zaporozhye region. Comparative analysis of obtained data was conducted in dynamics and with definition of specific weight of able to work population in structure of indexes and gender differences. In article we showed, that on the background of depopulation of Ukraine during last 20 years, prevalence of diseases of the circulatory system increased by 2 times, and level of mortality from them increased for 45%. Specific weight of mortality from diseases of the circulatory system among adult population (state for 01.2013 y. in Ukraine was 65,7%, in Zaporozhye region – 63,6%, among able to work population – 30,5%, in Zaporozhye region – 33,4%, but mortality among able to work men in Zaporozhye region was in 5,5 times higher than in women. Specific weight of the diseases of the circulatory system in structure of general morbidity in total population in Ukraine was 31,5%, among able to work population – 24,1%; among total population of Zaporozhye region – 36,6% (in town – 35,0%; in country region – 39,8%, among able to work population of Zaporozhye region – 24,6% (in town – 22,8%; in country region – 27,6%. Structure of general morbidity of the cardiovascular diseases during last 10 years in Ukraine and in Zaporozhye region is stable. Leading place belongs to arterial hypertension: 56,1%- in Ukraine, 57,7 % - in Zaporozhye region. Comparing to Ukraine, before 2005 y

  4. Advanced Spacesuit Portable Life Support System Packaging Concept Mock-Up Design & Development

    Science.gov (United States)

    O''Connell, Mary K.; Slade, Howard G.; Stinson, Richard G.

    1998-01-01

    A concentrated development effort was begun at NASA Johnson Space Center to create an advanced Portable Life Support System (PLSS) packaging concept. Ease of maintenance, technological flexibility, low weight, and minimal volume are targeted in the design of future micro-gravity and planetary PLSS configurations. Three main design concepts emerged from conceptual design techniques and were carried forth into detailed design, then full scale mock-up creation. "Foam", "Motherboard", and "LEGOtm" packaging design concepts are described in detail. Results of the evaluation process targeted maintenance, robustness, mass properties, and flexibility as key aspects to a new PLSS packaging configuration. The various design tools used to evolve concepts into high fidelity mock ups revealed that no single tool was all encompassing, several combinations were complimentary, the devil is in the details, and, despite efforts, many lessons were learned only after working with hardware.

  5. How tangible mock-ups support design collaboration

    DEFF Research Database (Denmark)

    Brandt, Eva

    2007-01-01

    This paper is a contribution to a more conscious use of tangible mock-ups in collaborative design processes. It describes a design team's use of mock-ups in a series of workshops involving potential customers and users. Focus is primarily on the use of three-dimensional design mock-ups and how...... differences in these affected the dialogue. Reflective conversations were established by using tangible mock-ups as 'things-to-think with'. They served as boundary objects that spanned the gap between the different competencies and interests of participants in design. The design mock-ups evoked different...... things for different participants whereas the challenge for the design team was to find boundaries upon which everybody could agree. The level of details represented in a mock-up affected the communication so that a mock-up with few details evoked different issues whereas a very detailed mock-up evoked...

  6. Development of a digital mock-up system for selecting a decommissioning scenario

    International Nuclear Information System (INIS)

    Kim, Sung-Kyun; Park, Hee-Sung; Lee, Kune-Woo; Jung, Chong-Hun

    2006-01-01

    The evaluation of decommissioning scenarios is critical to the successful development and execution of a decommissioning project. In the past, many experts have used a physical mock-up system to find the exact work processes and the working positions. Nowadays, these jobs are being done by a Digital Mock-Up (DMU) system. The DMU, which is a technology to realize an effective work process by using virtual environments through representing the physical and logical schema and the behavior of a real decommissioning work, can save on the cost and time, reduce the risk of making later changes, and develop various decommissioning scenarios. In this research, a decommissioning DMU system was developed for simulating the relevant dismantling processes. Decommissioning data-computing modules which can calculate a dismantling schedule, quantify a radioactive waste, visualize a radioactive inventory, estimate a decommissioning cost, and estimate a worker's exposure were also developed to qualitatively assess the decommissioning information. And an analytic hierarchy process (AHP) model was developed to evaluate the decommissioning scenarios which reflected the quantitative and qualitative considerations. To establish the proper scenario for the thermal column in KRR-1, the developed decommissioning DMU system was applied to evaluate the two candidate scenarios of it

  7. Favorable circulatory system outcomes as adjuvant traditional Chinese medicine (TCM treatment for cerebrovascular diseases in Taiwan.

    Directory of Open Access Journals (Sweden)

    Hsienhsueh Elley Chiu

    Full Text Available This study searches the National Health Insurance Research Database (NHIRD used in a previous project, aiming for reconstructing possible cerebrovascular disease-related groups (DRG,and estimating the costs between cerebrovascular disease and related diseases.We conducted a nationwide retrospective cohort study in stroke inpatients, we examined the overall costs in 3 municipalities in Taiwan, by evaluating the possible costs of the expecting diagnosis related group (DRG by using the international classification of diseases version-9 (ICD-9 system, and the overall analysis of the re-admission population that received traditional Chinese medicine (TCM treatment and those who did not.The trend demonstrated that the non-participant costs were consistent with the ICD-9 categories (430 to 437 because similarities existed between years 2006 to 2007. Among the TCM patients, a wide variation and additional costs were found compared to non-TCM patients during these 2 years. The average re-admission duration was significantly shorter for TCM patients, especially those initially diagnosed with ICD 434 during the first admission. In addition, TCM patients demonstrated more severe general symptoms, which incurred high conventional treatment costs, and could result in re-admission for numerous reasons. However, in Disease 7 of ICD-9 category, representing the circulatory system was most prevalent in non-TCM inpatients, which was the leading cause of re-admission.We concluded that favorable circulatory system outcomes were in adjuvant TCM treatment inpatients, there were less re-admission for circulatory system events and a two-third reduction of re-admission within ICD-9 code 430 to 437, compared to non-TCM ones. However, there were shorter re-admission duration other than circulatory system events by means of unfavorable baseline condition.

  8. U arm type x-ray radiograph system for circulatory system

    International Nuclear Information System (INIS)

    Kiuchi, Shigeo; Kaga, Yuji; Sato, Masami; Komatsuda, Yasushi; Nishio, Kosaku.

    1979-01-01

    This report is concerned with the function and usefulness of U arm type X-ray radiograph system for circulatory system jointly developed by Yamagata University and Toshiba Medical Co., Ltd. The system was used 560 times in 2 years mostly for cinephotography. It has such features as follows: (1) The compound oblique position radiography mechanism of U arm is useful for the separative radiography around coronary artery. (2) The mechanism of U arm is very quick in photographing with fluoroscopy. (3) Very sharp II indirect biplane photographs without obscurity due to enlarging can be taken. (4) An operator can position objects readily by operating a sterilizing switch. (5) Both short time photographing of 1 m sec and high speed repeated photographing of 12 times/sec can be made with the photo timer. (6) The fog due to mutual scattering in RSC biplane photographing can be removed by II blanking method. (Kobatake, H.)

  9. Evaluation of a mock interview session on residency interview skills.

    Science.gov (United States)

    Buckley, Kelsey; Karr, Samantha; Nisly, Sarah A; Kelley, Kristi

    2018-04-01

    To evaluate the impact of student pharmacist participation in a mock interview session on confidence level and preparation regarding residency interview skills. The study setting was a mock interview session, held in conjunction with student programming at the American College of Clinical Pharmacy (ACCP) Annual Meeting. Prior to the mock interview session, final year student pharmacists seeking residency program placement were asked to complete a pre-session survey assessing confidence level for residency interviews. Each student pharmacist participated in up to three mock interviews. A post-session survey evaluating confidence level was then administered to consenting participants. Following the American Society for Health-System Pharmacists (ASHP) Pharmacy Resident Matching Program (RMP), a post-match electronic survey was sent to study participants to determine their perception of the influence of the mock interview session on achieving successful interactions during residency interviews. A total of 59 student pharmacists participated in the mock interview session and completed the pre-session survey. Participants completing the post-session survey (88%, n = 52) unanimously reported an enhanced confidence in interviewing skills following the session. Thirty responders reported a program match rate of 83%. Approximately 97% (n = 29) of the respondents agreed or strongly agreed that the questions asked during the mock interview session were reflective of questions asked during residency interviews. Lessons learned from this mock interview session can be applied to PGY1 residency mock interview sessions held locally, regionally, and nationally. Students participating in the ACCP Mock Interview Session recognized the importance of the interview component in obtaining a postgraduate year 1 (PGY1) pharmacy residency. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Set-up of a pre-test mock-up experiment in preparation for the HCPB Breeder Unit mock-up experimental campaign

    Energy Technology Data Exchange (ETDEWEB)

    Hernández, F., E-mail: francisco.hernandez@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Kolb, M. [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials (IAM-WPT) (Germany); Ilić, M.; Kunze, A. [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Németh, J. [KFKI Research Institute for Particle and Nuclear Physics (Hungary); Weth, A. von der [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany)

    2013-10-15

    Highlights: ► As preparation for the HCPB-TBM Breeder Unit out-of-pile testing campaign, a pre-test experiment (PREMUX) has been prepared and described. ► A new heater system based on a wire heater matrix has been developed for imitating the neutronic volumetric heating and it is compared with the conventional plate heaters. ► The test section is described and preliminary thermal results with the available models are presented and are to be benchmarked with PREMUX. ► The PREMUX integration in the air cooling loop L-STAR/LL in the Karlsruhe Institute for Technology is shown and future steps are discussed. -- Abstract: The complexity of the experimental set-up for testing a full-scaled Breeder Unit (BU) mock-up for the European Helium Cooled Pebble Bed Test Blanket Module (HCPB-TBM) has motivated to build a pre-test mock-up experiment (PREMUX) consisting of a slice of the BU in the Li{sub 4}SiO{sub 4} region. This pre-test aims at verifying the feasibility of the methods to be used for the subsequent testing of the full-scaled BU mock-up. Key parameters needed for the modeling of the breeder material is also to be determined by the Hot Wire Method (HWM). The modeling tools for the thermo-mechanics of the pebble beds and for the mock-up structure are to be calibrated and validated as well. This paper presents the setting-up of PREMUX in the L-STAR/LL facility at the Karlsruhe Institute of Technology. A key requirement of the experiments is to mimic the neutronic volumetric heating. A new heater concept is discussed and compared to several conventional heater configurations with respect to the estimated temperature distribution in the pebble beds. The design and integration of the thermocouple system in the heater matrix and pebble beds is also described, as well as other key aspects of the mock-up (dimensions, layout, cooling system, purge gas line, boundary conditions and integration in the test facility). The adequacy of these methods for the full-scaled BU

  11. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    Science.gov (United States)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  12. A microfluidic circulatory system integrated with capillary-assisted pressure sensors.

    Science.gov (United States)

    Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai

    2017-02-14

    The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.

  13. Mock-up test on key components of ITER blanket remote handling system

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Kakudate, Satoshi; Nakahira, Masataka; Matsumoto, Yasuhiro; Taguchi, Koh; Kozaka, Hiroshi; Shibanuma, Kiyoshi; Tesini, Alessandro

    2009-01-01

    The maintenance operation of the ITER in-vessel component, such as a blanket and divertor, must be executed by the remote equipment because of the high gamma-ray environment. During the Engineering Design Activity (EDA), the Japan Atomic Energy Agency (then called as Japan Atomic Energy Research Institute) had been fabricated the prototype of the vehicle manipulator system for the blanket remote handling and confirmed feasibility of this system including automatic positioning of the blanket and rail deployment procedure of the articulated rail. The ITER agreement, which entered into force in the last year, formally decided that Japan will procure the blanket remote handling system and the JAEA, as the Japanese Domestic Agency, is continuing several R and Ds so that the system can be procured smoothly. The residual key issues after the EDA are rail connection and cable handling. The mock-ups of the rail connection mechanism and the cable handling system were fabricated from the last year and installed at the JAEA Naka Site in this March. The former was composed of the rail connecting mechanism, two rail segments and their handling systems. The latter one utilized a slip ring, which implemented 80 lines for power and 208 lines for signal, because there is an electrical contact between the rotating spool and the fixed base. The basic function of these systems was confirmed through the mock-up test. The rail connection mechanism, for example, could accept misalignment of 1.5-2 mm at least. The future test plan is also mentioned in the paper.

  14. A Mock UF6 Feed and Withdrawal System for Testing Safeguards Monitoring Systems and Strategies Intended for Nuclear Fuel Enrichment and Processing Plants

    International Nuclear Information System (INIS)

    Krichinsky, Alan M.; Bates, Bruce E.; Chesser, Joel B.; Koo, Sinsze; Whitaker, J. Michael

    2009-01-01

    This report describes an engineering-scale, mock UF6 feed and withdrawal (F and W) system, its operation, and its intended uses. This system has been assembled to provide a test bed for evaluating and demonstrating new methodologies that can be used in remote, unattended, continuous monitoring of nuclear material process operations. These measures are being investigated to provide independent inspectors improved assurance that operations are being conducted within declared parameters, and to increase the overall effectiveness of safeguarding nuclear material. Testing applicable technologies on a mock F and W system, which uses water as a surrogate for UF6, enables thorough and cost-effective investigation of hardware, software, and operational strategies before their direct installation in an industrial nuclear material processing environment. Electronic scales used for continuous load-cell monitoring also are described as part of the basic mock F and W system description. Continuous monitoring components on the mock F and W system are linked to a data aggregation computer by a local network, which also is depicted. Data collection and storage systems are described only briefly in this report. The mock UF 6 F and W system is economical to operate. It uses a simple process involving only a surge tank between feed tanks and product and withdrawal (or waste) tanks. The system uses water as the transfer fluid, thereby avoiding the use of hazardous UF 6 . The system is not tethered to an operating industrial process involving nuclear materials, thereby allowing scenarios (e.g., material diversion) that cannot be conducted otherwise. These features facilitate conducting experiments that yield meaningful results with a minimum of expenditure and quick turnaround time. Technologies demonstrated on the engineering-scale system lead to field trials (described briefly in this report) for determining implementation issues and performance of the monitoring technologies under

  15. Miniature circulatory systems: A new exposure system for ecotoxicological effect assessments in riverine organisms.

    Science.gov (United States)

    Feiner, Mona; Beggel, Sebastian; Geist, Juergen

    2016-11-01

    Long-term effect assessments in ecotoxicological investigations are important, yet there is a lack of suitable exposure systems for these experiments that can be used for riverine species. A cost-efficient miniature circulatory system was developed that was evaluated for its applicability in long-term exposures in 2 stream-dwelling species: brown trout (Salmo trutta) and an amphipod (Gammarus roeseli). In an egg-to-fry exposure of S. trutta, the toxicity of 2 reverse osmosis concentrates was investigated as examples. Control hatching rate of yolk sac fry was 75 ± 7% and thus complies with the Organisation for Economic Co-operation and Development validity criterion (≥66%). The reverse osmosis concentrates did not impair the hatching rate in any tested concentration. In G. roeseli, mortality rates remained below 20% during a 21-d cultivation, fulfilling the common validity criterion in ecotoxicological testing. Mortality was significantly lower when the species was fed with conditioned alder leaves instead of an artificial shrimp food. Finally, a toxicity test on G. roeseli using copper as the test substance revealed median lethal concentration (LC50) values of 156 μg/L after 96 h and 99 μg/L after 264 h, which is in line with literature findings using other accepted exposure units. In conclusion, the miniature circulatory system provides a novel and cost-efficient exposure system for long-term investigations on riverine species that may also be applicable for other species of fishes and macroinvertebrates. Environ Toxicol Chem 2016;35:2827-2833. © 2016 SETAC. © 2016 SETAC.

  16. Noninvasive optoacoustic system for rapid diagnostics and management of circulatory shock

    Science.gov (United States)

    Esenaliev, Rinat O.; Petrov, Irene Y.; Petrov, Yuriy; Kinsky, Michael; Prough, Donald S.

    2012-02-01

    Circulatory shock is lethal, if not promptly diagnosed and effectively treated. Typically, circulatory shock resuscitation is guided by blood pressure, heart rate, and mental status, which have poor predictive value. In patients, in whom early goaldirected therapy was applied using central venous oxygenation measurement, a substantial reduction of mortality was reported (from 46.5% to 30%). However, central venous catheterization is invasive, time-consuming and often results in complications. We proposed to use the optoacoustic technique for noninvasive, rapid assessment of central venous oxygenation. In our previous works we demonstrated that the optoacoustic technique can provide measurement of blood oxygenation in veins and arteries due to high contrast and high resolution. In this work we developed a novel optoacoustic system for noninvasive, automatic, real-time, and continuous measurement of central venous oxygenation. We performed pilot clinical tests of the system in human subjects with different oxygenation in the internal jugular vein and subclavian vein. A novel optoacoustic interface incorporating highly-sensitive optoacoustic probes and standard ultrasound imaging probes were developed and built for the study. Ultrasound imaging systems Vivid i and hand-held Vscan (GE Healthcare) as well as Site-Rite 5 (C.R. Bard) were used in the study. We developed a special algorithm for oxygenation monitoring with minimal influence of overlying tissue. The data demonstrate that the system provides precise measurement of venous oxygenation continuously and in real time. Both current value of the venous oxygenation and trend (in absolute values and for specified time intervals) are displayed in the system. The data indicate that: 1) the optoacoustic system developed by our group is capable of noninvasive measurement of blood oxygenation in specific veins; 2) clinical ultrasound imaging systems can facilitate optoacoustic probing of specific blood vessels; 3) the

  17. Head capsule, chephalic central nervous system and head circulatory system of an aberrant orthopteran, Prosarthria teretrirostris (Caelifera, Hexapoda).

    Science.gov (United States)

    Baum, Eileen; Hertel, Wieland; Beutel, Rolf Georg

    2007-01-01

    The head capsule, the circulatory system and the central nervous system of the head of Prosarthria teretrirostris (Proscopiidae) is described in detail, with special consideration of modifications resulting from the aberrant head shape. The transformations of the head are completely different from those found in phasmatodeans, which are also characterised by twig mimesis. The circulatory system is distinctly modified. A hitherto undescribed additional structure in the posterior head region very likely functions as a pulsatile organ. The cephalic central nervous system is strongly elongated, with changes in the position of the suboesophageal ganglion, the corpora cardiaca and the course of the nervus mandibularis. Three-dimensional reconstructions of these two organ systems in combination with the pharynx were made using Alias Maya 6.0 software. Comparisons with other representatives of Caelifera suggest a clade comprising Proscopiidae and Morabinae. The presence of a transverse muscle connecting the antennal ampullae in Prosarthria shows that this structure likely belongs to the groundplan of Orthoptera, even though it is missing in different representatives of this group. The transverse ampullary muscle is a potential synapomorphy of Orthoptera, Phasmatodea and Dictyoptera.

  18. A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.

    Science.gov (United States)

    Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A

    2005-11-01

    While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.

  19. Implantable nuclear-fueled circulatory support system. V. Acute physiologic analyses

    Energy Technology Data Exchange (ETDEWEB)

    Huffman, F N; Migliore, J J; Hagen, K G; Daly, B D.T.; Robinson, W J; Ruggles, A E; Norman, J C

    1973-01-01

    Nuclear-Fueled circulatory assist systems have reached the stage of in vivo evaluation. Physiologic studies of the effects of intracorporeal heat and radiation as well as blood pumps indicate that these factors should not preclude clinical application of nuclear artificial hearts. In the circulatory system under consideration, a fraction of the heat from a 50 watt Plutonium-238 fuel capsule is converted into hydraulic power for driving a left ventricular assist pump via a miniature, electronically controlled steam (tidal regenerator) engine. The engine is pressurized (8-140 PSIA) by the displacement of a single drop of water between the condenser (150/sup 0/F) and the boiler (360/sup 0/F). The electrical power for sensing, logic and displacement is provided by a thermoelectric module interposed between the superheater (900/sup 0/F) and boiler. The pusher plate pump also functions as a blood-cooled heat exchanger and sensor for the control logic. The assist pump is connected between the apex of the left ventricle and the descending thoracic aorta. The power source module is suspended in the left retroperitoneal cavity from the psoas tendon. The blood interface of the pump is flocked with polyester fibers. A stable biologic lining develops in the pump using Dextran as the only anticoagulant. The longest in vivo testing period has been 4/sup 1///sub 2/ days. Plasma hemoglobinshave remained below 10 mg/sup 0///sub 0/. Although rectal temperatures have not increased, elevated respiratory rates have been noted. Reduction of left ventricular pressure and dp/dt have been demonstrated with maintenance of arterial pressure.

  20. Feasibility study of the thermo-siphon mock-up test

    International Nuclear Information System (INIS)

    Choi, Jung Woon; Kim, Young Jin; Lee, Kye Hong; Kim, Young Ki; Jeong, Sang Kwon

    2004-09-01

    Described is the feasibility of the thermo-siphon mock-up test for the HANARO-CNS facility. The purposes of the mock-up tests are discussed in detail as the three concepts: for the detailed design, for the operation of the CNS facility, for the safety assurance of itself. This report considers the two stages of mock-up tests in terms of the experimental schedule and plan. As the first stage, the small-size mock-up test using Argon will be implemented to obtain the experience in the cryogenic fluid and to understand the basic concept of the CNS thermo-siphon. In the second stage, two kinds of mock-up tests are discussed: the full-scale mock-up test using liquid hydrogen or the integrated final test using hydrogen outside the reactor after the full-scale mock-up test using Freon gas. The contents discussed in this report will be the basis or the guide lines for the mock-up test. In addition, the results of the mock-up test will be the foundation for the safe operation of the HANARO-CNS facility

  1. Low-frequency dynamics of autonomic regulation of circulatory system in healthy subjects

    Science.gov (United States)

    Skazkina, V. V.; Borovkova, E. I.; Galushko, T. A.; Khorev, V. S.; Kiselev, A. R.

    2018-04-01

    The paper is devoted to the analysis of dynamic of interactions between signals of autonomic circulatory regulation. We investigated two-hour experimental records of 30 healthy people. Phase synchronization was studied using the signals of the electrocardiogram and the photoplethysmogram of vessels. We found the presence of long synchronous intervals in some subjects. For analysis of the dynamic we calculated autocorrelation functions. The analysis made it possible to reveal indirect signs of the influence of the humoral regulation system.

  2. Preliminary analysis of West Valley Waste Removal System equipment development and mock demonstration facilities

    International Nuclear Information System (INIS)

    Janicek, G.P.

    1981-06-01

    This report defines seven areas requiring further investigation to develop and demonstrate a safe and viable West Valley Waste Removal System. These areas of endeavor are discussed in terms of their minimum facility requirements. It is concluded that utilizing separated specific facilities at different points in time is of a greater advantage than an exact duplication of the West Valley tanks. Savannah River Plant's full-scale, full-circle and half-circle tanks, and their twelfth scale model tank would all be useful to varying degrees but would require modifications. Hanford's proposed full-size mock tank would be useful, but is not seriously considered because its construction may not coincide with West Valley needs. Costs of modifying existing facilities and/or constructing new facilities are assessed in terms of their benefit to the equipment development and mock demonstration. Six facilities were identified for further analysis which would benefit development of waste removal equipment

  3. Annular tidal regenerator engine for nuclear circulatory support systems

    International Nuclear Information System (INIS)

    Hagen, K.G.; Ruggles, A.E.; Fam, S.S.; Torti, V.A.

    1975-01-01

    In order to simplify the configuration of the tidal regenerator engine nuclear-powered circulatory support system, thereby drastically reducing its size and improving the intrinsic reliability, the engine has been redesigned. This redesign focuses on allowing power to be extracted at the low temperature end of the engine utilizing a piston-cylinder arrangement wherein all of the necessary heat transfer processes occur in the annular gap between the piston and cylinder. In all other respects the engine retains its basic characteristics as a hybrid between a Stirling engine and a Rankine engine. A significant advantage of the new arrangement is the ability to raise the superheat temperature limit from 650 0 F to over 900 0 F. This has yielded an increase in engine efficiency from 10 percent to 14 percent, and further increases are anticipated by utilizing an expansion and/or a binary version of the engine. The implantable system volume has been reduced by a factor of three and orientation insensitivity with respect to gravity has been demonstrated. Many system components have already demonstrated endurances of several thousand hours

  4. Status of the Tidal Regenerator Engine for nuclear circulatory support systems

    International Nuclear Information System (INIS)

    Watelet, R.P.; Ruggles, A.E.; Torti, V.

    1976-01-01

    Based on the annular version of the Tidal Regenerator Engine, a packaged energy system for nuclear powered circulatory support systems was developed. Net power output of approximately 3 watts is delivered using a 33-watt heat source for an engine module volume of 0.7 liter and a weight of 1.6 kg. A higher efficiency dual cycle version of the annular engine using a Dowtherm A topping cycle on the basic steam cycle is also under development. Projected system output using this advanced engine is 5 watts for the same sized heat source. Life testing of critical components has demonstrated substantial reliability improvement over earlier designs. Of particular significance is the continuing operation of a complete implantable engine system after 1200 hours. Component life testing is continuing with over five thousand hours accumulated on two pump actuators employing welded metal bellows

  5. Burden of Circulatory System Diseases and Ignored Barriers ofKnowledge Translation

    Directory of Open Access Journals (Sweden)

    Hamed-Basir Ghafouri

    2012-10-01

    Full Text Available Circulatory system disease raise third highest disability-adjusted life years among Iranians and ischemic cardiac diseases are main causes for such burden. Despite available evidences on risk factors of the disease, no effective intervention was implemented to control and prevent the disease. This paper non-systematically reviews available literature on the problem, solutions, and barriers of implementation of knowledge translation in Iran. It seems that there are ignored factors such as cultural and motivational issues in knowledge translation interventions but there are hopes for implementation of started projects and preparation of students as next generation of knowledge transferors.

  6. Pediatric Donation After Circulatory Determination of Death: A Scoping Review.

    Science.gov (United States)

    Weiss, Matthew J; Hornby, Laura; Witteman, William; Shemie, Sam D

    2016-03-01

    Although pediatric donation after circulatory determination of death is increasing in frequency, there are no national or international donation after circulatory determination of death guidelines specific to pediatrics. This scoping review was performed to map the pediatric donation after circulatory determination of death literature, identify pediatric donation after circulatory determination of death knowledge gaps, and inform the development of national or regional pediatric donation after circulatory determination of death guidelines. Terms related to pediatric donation after circulatory determination of death were searched in Embase and MEDLINE, as well as the non-MEDLINE sources in PubMed from 1980 to May 2014. Seven thousand five hundred ninety-seven references were discovered and 85 retained for analysis. All references addressing pediatric donation after circulatory determination of death were considered. Exclusion criteria were articles that did not address pediatric patients, animal or laboratory studies, surgical techniques, and local pediatric donation after circulatory determination of death protocols. Narrative reviews and opinion articles were the most frequently discovered reference (25/85) and the few discovered studies were observational or qualitative and almost exclusively retrospective. Retained references were divided into themes and analyzed using qualitative methodology. The main discovered themes were 1) studies estimating the number of potential pediatric donation after circulatory determination of death donors and their impact on donation; 2) ethical issues in pediatric donation after circulatory determination of death; 3) physiology of the dying process after withdrawal of life-sustaining therapy; 4) cardiac pediatric donation after circulatory determination of death; and 5) neonatal pediatric donation after circulatory determination of death. Donor estimates suggest that pediatric donation after circulatory determination of death will

  7. Mechanical circulatory treatment of advanced heart failure

    DEFF Research Database (Denmark)

    Løgstrup, Brian B; Vase, Henrik; Gjedsted, Jakob

    2016-01-01

    Heart failure is one of the most common causes of morbidity and mortality worldwide. When patients cease to respond adequately to optimal medical therapy mechanical circulatory support has been promising. The advent of mechanical circulatory support devices has allowed significant improvements...... in patient survival and quality of life for those with advanced or end-stage heart failure. We provide a general overview of current mechanical circulatory support devices encompassing options for both short- and long-term ventricular support....

  8. Experimental investigation of the IFMIF target mock-up

    International Nuclear Information System (INIS)

    Loginov, N.; Mikheyev, A.; Morozov, V.; Aksenov, Yu.; Arnol'dov, M.; Berensky, L.; Fedotovsky, V.; Chernov, V.; Nakamura, H.

    2009-01-01

    The international fusion materials irradiation facility (IFMIF) lithium neutron target mock-ups have been constructed and tested at water and lithium test facilities in the IPPE of Russia. Jet velocity in both mock-ups was up to 20 m/s. Calculations and experiments showed lithium flow instability at conjunction point of straight and concave sections of the mock-up back wall. Water velocity profile across the mock-up width, jet thickness, and wave height were measured. The significant increase of thickness of both water and lithium jets near the mock-up sidewalls was observed. The influence of shape of the nozzle outlet part on jet stability was investigated. Lithium evaporation from the jet free surface was investigated as well as lithium deposition on vacuum pipe walls of the target mock-up. It was shown that these phenomena are not very critical for the target efficiency. The possibility of lithium denitration down to 2 ppm (at 10 ppm requested) by means of aluminium getter was shown. Two types of cold traps and plug indicators of impurities were tested. The results are presented in the paper.

  9. Status of the Digital Mock-up System for the dismantling of the nuclear facilities

    International Nuclear Information System (INIS)

    Park, Hee Seoung; Kim, S. K.; Lee, K. W.; Oh, W. J.

    2004-12-01

    The database system have already developed is impossible to solve a quantitative evaluation about a various situation from the dismantle activities of the reactor had contaminated with radioactivity. To satisfy the requirements for safety and economical efficiency among a major decommissioning technologies, it need a system that can evaluate and estimate dismantling scheduling, amount of radioactive waste being dismantled, and decommissioning cost. We have review and analyzed status of the digital mock-up system to get a technical guide because we have no experience establishment of one relation to dismantling of research reactor and nuclear power plant

  10. The Impact of Ionospheric and Geomagnetic Changes on Mortality from Diseases of the Circulatory System

    Czech Academy of Sciences Publication Activity Database

    Podolská, Kateřina

    2018-01-01

    Roč. 27, č. 2 (2018), s. 404-417 ISSN 1052-3057 Institutional support: RVO:68378289 Keywords : mortality * circulatory system diseases * solar indices * cluster analysis using time Subject RIV: DN - Health Impact of the Environment Quality OBOR OECD: Public and environmental health Impact factor: 1.517, year: 2016 http://www.strokejournal.org/article/S1052-3057(17)30488-3/fulltext

  11. Vacuum tests of a beamline front-end mock-up at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Liu, C.; Nielsen, R.W.; Kruy, T.L.; Shu, D.; Kuzay, T.M.

    1994-01-01

    A-mock-up has been constructed to test the functioning and performance of the Advanced Photon Source (APS) front ends. The mock-up consists of all components of the APS insertion-device beamline front end with a differential pumping system. Primary vacuum tests have been performed and compared with finite element vacuum calculations. Pressure distribution measurements using controlled leaks demonstrate a better than four decades of pressure difference between the two ends of the mock-up. The measured pressure profiles are consistent with results of finite element analyses of the system. The safety-control systems are also being tested. A closing time of ∼20 ms for the photon shutter and ∼7 ms for the fast closing valve have been obtained. Experiments on vacuum protection systems indicate that the front end is well protected in case of a vacuum breach

  12. Strength of Mock-up Trial Grout

    DEFF Research Database (Denmark)

    Sørensen, Eigil V.

    The present report describes tests carried out on samples taken and cast during the execution of a mock-up trial placement of the high performance grout MASTERFLOW 9500 on January 21, 2009.......The present report describes tests carried out on samples taken and cast during the execution of a mock-up trial placement of the high performance grout MASTERFLOW 9500 on January 21, 2009....

  13. Mock MRI: reducing the need for anaesthesia in children

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Amanda J. [Royal Children' s Hospital, Department of Occupational Therapy, Queensland (Australia); Greer, Mary-Louise C.; Gray, Simon E. [Royal Children' s Hospital, Department of Medical Imaging, Queensland (Australia); Ware, Robert S. [School of Public Health, University of Queensland, Queensland (Australia)

    2010-08-15

    With a longer waiting list for paediatric MRI performed under general anaesthesia (GA) and considering safety concerns, the Royal Children's Hospital Brisbane established a mock MRI service. The aim of this service is to reduce the requirement for MRI under GA. The objective of this study was to test the hypothesis that the percentage of children ages 3 years to 14 years in the study period that required general anaesthesia would be less with mock MRI when compared to standard practise. A retrospective audit of clinical data was conducted to examine the impact of mock MRI on the GA rate for clinical MRI. Results indicated the addition of a mock MRI reduced the need for GA most significantly for children ages 3 to 8 years. In this age group, the rate of GA was 16.8% lower than that of the non-mock MRI group (P = <0.05). Mock MRI reduces the need for GA in children with the greatest effect evident in children aged between 3 and 8 years. (orig.)

  14. XML-based assembly visualization for a multi-CAD digital mock-up system

    International Nuclear Information System (INIS)

    Song, In Ho; Chung, Sung Chong

    2007-01-01

    Using a virtual assembly tool, engineers are able to design accurate and interference free parts without making physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product in a distributed design environment. In this paper, a multi-CAD assembly method is proposed through an XML and the lightweight CAD file. XML data contains a hierarchy of the multi-CAD assembly. The lightweight CAD file produced from various CAD files through the ACIS kemel and InterOp includes not only mesh and B-Rep data, but also topological data. It is used to visualize CAD data and to verify dimensions of the parts. The developed system is executed on desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Multi-CAD models have been assembled to verify the effectiveness of the developed DMU system on the Internet

  15. Numerical Models of Human Circulatory System under Altered Gravity: Brain Circulation

    Science.gov (United States)

    Kim, Chang Sung; Kiris, Cetin; Kwak, Dochan; David, Tim

    2003-01-01

    A computational fluid dynamics (CFD) approach is presented to model the blood flow through the human circulatory system under altered gravity conditions. Models required for CFD simulation relevant to major hemodynamic issues are introduced such as non-Newtonian flow models governed by red blood cells, a model for arterial wall motion due to fluid-wall interactions, a vascular bed model for outflow boundary conditions, and a model for auto-regulation mechanism. The three-dimensional unsteady incompressible Navier-Stokes equations coupled with these models are solved iteratively using the pseudocompressibility method and dual time stepping. Moving wall boundary conditions from the first-order fluid-wall interaction model are used to study the influence of arterial wall distensibility on flow patterns and wall shear stresses during the heart pulse. A vascular bed modeling utilizing the analogy with electric circuits is coupled with an auto-regulation algorithm for multiple outflow boundaries. For the treatment of complex geometry, a chimera overset grid technique is adopted to obtain connectivity between arterial branches. For code validation, computed results are compared with experimental data for steady and unsteady non-Newtonian flows. Good agreement is obtained for both cases. In sin-type Gravity Benchmark Problems, gravity source terms are added to the Navier-Stokes equations to study the effect of gravitational variation on the human circulatory system. This computational approach is then applied to localized blood flows through a realistic carotid bifurcation and two Circle of Willis models, one using an idealized geometry and the other model using an anatomical data set. A three- dimensional anatomical Circle of Willis configuration is reconstructed from human-specific magnetic resonance images using an image segmentation method. The blood flow through these Circle of Willis models is simulated to provide means for studying gravitational effects on the brain

  16. A faculty-led mock residency interview exercise for fourth-year doctor of pharmacy students.

    Science.gov (United States)

    Koenigsfeld, Carrie F; Wall, Geoffrey C; Miesner, Andrew R; Schmidt, Ginelle; Haack, Sally L; Eastman, Darla K; Grady, Sarah; Fornoff, Anisa

    2012-02-01

    To determine whether a faculty-led mock-interview activity enhanced pharmacy student preparation for the residency interview process and increased match rates. Twenty-eight doctor of pharmacy students volunteered for a 40-minute mock-interview session with 2-person faculty teams. A standard roster of 12 interview questions was derived from published literature and the faculty members' experience. Feedback on the student's interview performance was provided verbally during the session. Following the interview, students were given a 2-part survey instrument. The first part of the survey was administered immediately following the mock-interview session and the second part was administered after the standard date for residency program results (known as "Match Day"). Participant match rates were compared to American Society of Health-System Pharmacists (ASHP) national rates. 82.5% (23 of 27) of students in the mock-interview group matched a postgraduate year 1 (PGY1) program. Compared to national rates (61.9%), more students in our surveyed mock-interview group matched a PGY1 residency (P = .015; odds ratio [OR] 3.546, 95% CI 1.161-12.116). Higher match rates were seen in the students completing the mock residency interview compared to ASHP national rates. In general, students completing the mock interview found the process helpful and felt better prepared for their residency interviews.

  17. Donations After Circulatory Death in Liver Transplant.

    Science.gov (United States)

    Eren, Emre A; Latchana, Nicholas; Beal, Eliza; Hayes, Don; Whitson, Bryan; Black, Sylvester M

    2016-10-01

    The supply of liver grafts for treatment of end-stage liver disease continues to fall short of ongoing demands. Currently, most liver transplants originate from donations after brain death. Enhanced utilization of the present resources is prudent to address the needs of the population. Donation after circulatory or cardiac death is a mechanism whereby the availability of organs can be expanded. Donations after circulatory death pose unique challenges given their exposure to warm ischemia. Technical principles of donations after circulatory death procurement and pertinent studies investigating patient outcomes, graft outcomes, and complications are highlighted in this review. We also review associated risk factors to suggest potential avenues to achieve improved outcomes and reduced complications. Future considerations and alternative techniques of organ preservation are discussed, which may suggest novel strategies to enhance preservation and donor expansion through the use of marginal donors. Ultimately, without effective measures to bolster organ supply, donations after circulatory death should remain a consideration; however, an understanding of inherent risks and limitations is necessary.

  18. The Rhetoric of Mock Trial Debate: Using Logos, Pathos and Ethos in Undergraduate Competition

    Science.gov (United States)

    Walker, Felicia R.

    2005-01-01

    While engaging in learning about roles of evidence, rules of procedure and case law, undergraduate mock trial students must also learn how to effectively communicate their evidence to the fact-finder. In mock trial, as in real courtroom trials in the United States legal system, communication skills and the ability to persuade are essential. This…

  19. Mock Games: A New Genre of Pervasive Play

    DEFF Research Database (Denmark)

    Brynskov, Martin; Ludvigsen, Martin

    2006-01-01

    mock games as a genre and show that it is not covered well by any one of the reviewed theories, taking into account both social and technical aspects. Then we present a design example of such a system, DARE! We conclude by discussing ethical issues and set goals for future research....

  20. Digital mock-up for the spent fuel disassembly processes

    International Nuclear Information System (INIS)

    Lee, J. Y.; Kim, S. H.; Song, T. G.; Kim, Y. H.; Hong, D. H.; Yoon, J. S.

    2000-12-01

    In this study, the graphical design system is developed and the digital mock-up is implemented for designing the spent fuel handling and disassembly processes. The system consists of a 3D graphical modeling system, a devices assembling system, and a motion simulation system. This system is used throughout the design stages from the conceptual design to the motion analysis. By using this system, all the process involved in the spent fuel handling and disassembly processes are analyzed and optimized. Also, this system is used in developing the on-line graphic simulator which synchronously simulates the motion of the equipment in a real time basis by connecting the device controllers with the graphic server through the TCP/IP network. This simulator can be effectively used for detecting the malfunctions of the process equipment which is remotely operated. Thus, the simulator enhances the reliability and safety of the spent fuel handling process by providing the remote monitoring function of the process. The graphical design system and the digital mock-up system can be effectively used for designing the process equipment, as well as the optimized process and maintenance process. And the on-line graphic simulator can be an alternative of the conventional process monitoring system which is a hardware based system

  1. Circulatory mitochondrial DNA is a pro-inflammatory agent in maintenance hemodialysis patients.

    Directory of Open Access Journals (Sweden)

    Hongdi Cao

    Full Text Available Chronic inflammation is highly prevalent in maintenance hemodialysis (MHD patients, and it has been shown to be a strong predictor of morbidity and mortality. Mitochondrial DNA (mtDNA released into circulation after cell damage can promote inflammation in patients and animal models. However, the role and mechanisms of circulatory mtDNA in chronic inflammation in MHD patients remain unknown. Sixty MHD patients and 20 health controls were enrolled in this study. The circulatory mtDNA was detected by quantitative real-time PCR assay. Plasma interleukin 6 (IL-6 and tumor necrosis factor α (TNF-α were quantitated by ELISA assay. Dialysis systems in MHD patients and in vitro were used to evaluate the effect of different dialysis patterns on circulatory mtDNA. Circulatory mtDNA was elevated in MHD patients comparing to that of health control. Regression analysis demonstrated that plasma mtDNA was positively associated with TNF-α and the product of serum calcium and phosphorus, while negatively associated with hemoglobin and serum albumin in MHD patients. MtDNA induced the secretion of IL-6 and TNF-α in the THP-1 cells. Single high-flux hemodialysis (HF-HD and on line hemodiafiltration (OL-HDF but not low-flux hemodialysis (LF-HD could partially reduce plasma mtDNA in MHD patients. In vitro, both HD and hemofiltration (HF could fractional remove mtDNA. Collectively, circulatory mtDNA is elevated and its level is closely correlated with chronic inflammation in MHD patients. HF-HD and HDF can partially reduce circulatory mtDNA in MHD patients.

  2. How do Tangible Mock-U Support Design Collaboration?

    DEFF Research Database (Denmark)

    Brandt, Eva

    differences in these affected the dialogue. Reflective conversations were established by using tangible mock-ups as "things-to-think with". They served as boundary objects that spanned the gab between the different competencies and interests of participants in design. The design mock-ups evoked different...

  3. Tool coupling for the design and operation of building energy and control systems based on the Functional Mock-up Interface standard

    Energy Technology Data Exchange (ETDEWEB)

    Nouidui, Thierry Stephane; Wetter, Michael

    2014-03-01

    This paper describes software tools developed at the Lawrence Berkeley National Laboratory (LBNL) that can be coupled through the Functional Mock-up Interface standard in support of the design and operation of building energy and control systems. These tools have been developed to address the gaps and limitations encountered in legacy simulation tools. These tools were originally designed for the analysis of individual domains of buildings, and have been difficult to integrate with other tools for runtime data exchange. The coupling has been realized by use of the Functional Mock-up Interface for co-simulation, which standardizes an application programming interface for simulator interoperability that has been adopted in a variety of industrial domains. As a variety of coupling scenarios are possible, this paper provides users with guidance on what coupling may be best suited for their application. Furthermore, the paper illustrates how tools can be integrated into a building management system to support the operation of buildings. These tools may be a design model that is used for real-time performance monitoring, a fault detection and diagnostics algorithm, or a control sequence, each of which may be exported as a Functional Mock-up Unit and made available in a building management system as an input/output block. We anticipate that this capability can contribute to bridging the observed performance gap between design and operational energy use of buildings.

  4. Life expectancy and death by diseases of the circulatory system in patients with bipolar disorder or schizophrenia in the Nordic countries

    DEFF Research Database (Denmark)

    Laursen, Thomas Munk; Wahlbeck, Kristian; Hällgren, Jonas

    2013-01-01

    Excess mortality from diseases and medical conditions (natural death) in persons with psychiatric disorders has been extensively reported. Even in the Nordic countries with well-developed welfare systems, register based studies find evidence of an excess mortality. In recent years, cardiac...... mortality and death by diseases of the circulatory system has seen a decline in all the Nordic countries, but a recent paper indicates that women and men in Denmark, Finland, and Sweden, who had been hospitalised for a psychotic disorder, had a two to three-fold increased risk of dying from a cardiovascular...... disease. The aim of this study was to compare the mortality by diseases of the circulatory system among patients with bipolar disorder or schizophrenia in the three Nordic countries Denmark, Sweden, and Finland. Furthermore, the aim was to examine and compare life expectancy among these patients. Cause...

  5. The HIE-ISOLDE alignment and monitoring system software and test mock up

    CERN Document Server

    Kautzmann, G; Kadi, Y; Leclercq, Y; Waniorek, S; Williams, L

    2012-01-01

    For the HIE Isolde project a superconducting linac will be built at CERN in the Isolde facility area. The linac will be based on the creation and installation of 2 high- β and 4 low- β cryomodules containing respectively 5 high-β superconducting cavities and 1 superconducting solenoid for the two first ones, 6 low-β superconducting cavities and 2 superconducting solenoids for the four other ones. An alignment and monitoring system of the RF cavities and solenoids placed inside the cryomodules is needed to reach the optimum linac working conditions. The alignment system is based on opto-electronics, optics and precise mechanical instrumentation. The geometrical frame configuration, the data acquisition and the 3D adjustment will be managed using a dedicated software application. In parallel to the software development, an alignment system test mock-up has been built for software validation and dimensional tests. This paper will present the software concept and the development status, and then will describe...

  6. Diseases of the circulatory system among adult people diagnosed with infantile autism as children

    DEFF Research Database (Denmark)

    Mouridsen, Svend Erik; Rich, Bente; Isager, Torben

    2016-01-01

    BACKGROUND: Research dealing with adult people with autism spectrum disorders (ASD) noticeably lags behind studies of children and young individuals with ASD. AIMS: The objective of this study was to compare the prevalence and types of diseases of the circulatory system in a clinical sample of 118...... adult people diagnosed with infantile autism (IA) as children with 336 sex and age matched controls from the general population. METHODS AND PROCEDURES: All participants were screened through the nationwide Danish National Hospital Register. The average observation time of both groups was 37.2 years...

  7. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.

    Science.gov (United States)

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-12-01

    As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. The influence of sex on mock jurors' verdicts across type of child abuse cases.

    Science.gov (United States)

    Pettalia, Jennifer; Pozzulo, Joanna D; Reed, Jennifer

    2017-07-01

    This study examined the influence of victim sex, mock juror sex, and type of child abuse (physical, sexual, emotional, and neglect) on mock jurors' assessments of eyewitness and defendant integrity, continuous guilt ratings, dichotomous verdicts, and sentencing recommendations. Participants read one of eight versions of a trial transcript and then answered a self-report questionnaire. Female mock jurors were significantly more likely to find the defendant guilty overall. Moreover, female mock jurors recommended significantly longer sentences for defendants in sexual abuse cases; whereas, male mock jurors recommended significantly longer sentences for defendants in sexual and physical abuse cases. Male mock jurors perceived the defendant more favorably than female mock jurors; whereas, female mock jurors perceived the alleged victim more favorable than male mock jurors. These results suggest that juror sex may be an influential factor in child abuse cases overall. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Fabrication and testing of small scale mock-ups of ITER shielding blanket

    International Nuclear Information System (INIS)

    Hatano, Toshihisa; Sato, Satoshi; Suzuki, Satoshi; Yokoyama, Kenji; Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Takatsu, Hideyuki; Ohara, Yoshihiro

    1998-12-01

    Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully fabricated with a satisfactory dimensional accuracy. The small scale primary first wall mock-up was thermo-mechanically tested under high heat fluxes of 5-7 MW/m 2 for 2500 cycles in total. Satisfactory heat removal performance and integrity of the mock-up against cyclic high heat flux loads were confirmed by measurement during the tests and destructive examination after the tests. Similar high heat flux tests were also performed with the small scale baffle first wall mock-up under 5-10 MW/m 2 for 4500 cycles in total resulting in sufficient heat removal capability and integrity confirmed by measurements during the tests. (author)

  10. Fabrication and testing of small scale mock-ups of ITER shielding blanket

    Energy Technology Data Exchange (ETDEWEB)

    Hatano, Toshihisa; Sato, Satoshi; Suzuki, Satoshi; Yokoyama, Kenji; Furuya, Kazuyuki; Kuroda, Toshimasa; Enoeda, Mikio; Takatsu, Hideyuki; Ohara, Yoshihiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1998-12-01

    Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first wall mock-up, a two-step brazing was tried. All mock-ups and the partial model were successfully fabricated with a satisfactory dimensional accuracy. The small scale primary first wall mock-up was thermo-mechanically tested under high heat fluxes of 5-7 MW/m{sup 2} for 2500 cycles in total. Satisfactory heat removal performance and integrity of the mock-up against cyclic high heat flux loads were confirmed by measurement during the tests and destructive examination after the tests. Similar high heat flux tests were also performed with the small scale baffle first wall mock-up under 5-10 MW/m{sup 2} for 4500 cycles in total resulting in sufficient heat removal capability and integrity confirmed by measurements during the tests. (author)

  11. Effect of 5E Instructional Model in Student Success in Primary School 6th Year Circulatory System Topic

    Science.gov (United States)

    Cardak, Osman; Dikmenli, Musa; Saritas, Ozge

    2008-01-01

    The aim of this study is to research the effect of the 5E instructional model on primary (sixth grade) student success during the circulatory system unit. This study was conducted with 38 students in two different classes by the same researcher in 2006-2007. One of the classes was assigned as the control group and the other as the experimental…

  12. Mock climate summit: teaching and assessing learning

    Science.gov (United States)

    Schweizer, D.; Gautier, C.; Bazerman, C.

    2003-04-01

    This paper will demonstrate the effectiveness of a Mock Climate Summit as a pedagogical approach for teaching the science and policy aspects of global climate change. The Mock Climate Summit is a student-centered course simulating the Conference of the Parties (COP) where international environmental protocols are negotiated. Compared to traditional lecture-based methods common in the geoscience classroom, the Mock Climate Summit uses negotiations and arguments to teach the interactions between these two “spheres” and demonstrate the depth and breadth of these interactions. Through a detailed assessment of students’ dialogue transcribed from video and audio tapes, we found that the nature of the student dialogue matures rapidly as they are given multiple opportunities to present, negotiate and argue a specific topic. Students’ dialogue progress from hypothetical (what-if) scenarios to action-oriented scenarios and implementation plans. The progression of the students’ dialogue shows increased comfort with the communities’ discourse as they take ownership of the point-of-view associated with their assumed roles.

  13. Circulatory Arrest, Brain Arrest and Death Determination

    Directory of Open Access Journals (Sweden)

    Sam David Shemie

    2018-03-01

    Full Text Available Technological advances, particularly in the capacity to support, replace or transplant failing organs, continue to challenge and refine our understanding of human death. Given the ability to reanimate organs before and after death, both inside and outside of the body, through reinstitution of oxygenated circulation, concepts related to death of organs (e.g. cardiac death are no longer valid. This paper advances the rationale for a single conceptual determination of death related to permanent brain arrest, resulting from primary brain injury or secondary to circulatory arrest. The clinical characteristics of brain arrest are the permanent loss of capacity for consciousness and loss of all brainstem functions. In the setting of circulatory arrest, death occurs after the arrest of circulation to the brain rather than death of the heart. Correspondingly, any intervention that resumes oxygenated circulation to the brain after circulatory arrest would invalidate the determination of death.

  14. Circulatory nucleosome levels are significantly increased in early and late-onset preeclampsia.

    Science.gov (United States)

    Zhong, Xiao Yan; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Holzgreve, Wolfgang; Hahn, Sinuhe

    2005-08-01

    Elevations in circulatory DNA, as measured by real-time PCR, have been observed in pregnancies with manifest preeclampsia. Recent reports have indicated that circulatory nucleosome levels are elevated in the periphery of cancer patients. We have now examined whether circulatory nucleosome levels are similarly elevated in cases with preeclampsia. Maternal plasma samples were prepared from 17 cases with early onset preeclampsia (34 weeks gestation) with 10 matched normotensive controls. Levels of circulatory nucleosomes were quantified by commercial ELISA (enzyme-linked immunosorbant assay). The level of circulatory nucleosomes was significantly elevated in both study preeclampsia groups, compared to the matched normotensive control group (p = 0.000 and p = 0.001, respectively). Our data suggests that preeclampsia is associated with the elevated presence of circulatory nucleosomes, and that this phenomenon occurs in both early- and late-onset forms of the disorder. Copyright 2005 John Wiley & Sons, Ltd.

  15. The Mock Research Paper

    Science.gov (United States)

    Clark, Carlton

    2008-01-01

    The mock research paper combines creative writing with academic writing and, in the process, breaks down that binary. This article describes a writing assignment that offers an introduction to the college research paper genre. This assignment helps students focus on crafting an argument and learning genre conventions while postponing until the…

  16. Interactive virtual mock-ups for Remote Handling compatibility assessment of heavy components

    Energy Technology Data Exchange (ETDEWEB)

    Oosterhout, J. van, E-mail: j.vanoosterhout@differ.nl [FOM Institute DIFFER (Dutch Institute for Fundamental Energy Research), Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M.; Koning, J.F. [Heemskerk Innovative Technology B.V., Jonckerweg 12, 2201 DZ Noordwijk 6 (Netherlands); Ronden, D.M.S.; Baar, M. de [FOM Institute DIFFER (Dutch Institute for Fundamental Energy Research), Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands)

    2014-10-15

    Highlights: •Specific ITER components require RHCA on hardware mock-ups. •Hardware mock-ups are expensive and have a long lead time. •Interactive Virtual Reality mock-ups are readily available and easily adapted. •This paper analysis and proposes improvements to simulator capabilities. -- Abstract: ITER standards Tesini (2009) require hardware mock-ups to validate the Remote Handling (RH) compatibility of RH class 1- and critical class 2-components. Full-scale mock-ups of large ITER components are expensive, have a long lead time and lose their relevance in case of design changes. Interactive Virtual Reality simulations with real time rigid body dynamics and contact interaction allow for RH Compatibility Assessment during the design iterations. This paper explores the use of interactive virtual mock-ups to analyze the RH compatibility of heavy component handling and maintenance. It infers generic maintenance operations from the analysis and proposes improvements to the simulator capabilities.

  17. Interactive virtual mock-ups for Remote Handling compatibility assessment of heavy components

    International Nuclear Information System (INIS)

    Oosterhout, J. van; Heemskerk, C.J.M.; Koning, J.F.; Ronden, D.M.S.; Baar, M. de

    2014-01-01

    Highlights: •Specific ITER components require RHCA on hardware mock-ups. •Hardware mock-ups are expensive and have a long lead time. •Interactive Virtual Reality mock-ups are readily available and easily adapted. •This paper analysis and proposes improvements to simulator capabilities. -- Abstract: ITER standards Tesini (2009) require hardware mock-ups to validate the Remote Handling (RH) compatibility of RH class 1- and critical class 2-components. Full-scale mock-ups of large ITER components are expensive, have a long lead time and lose their relevance in case of design changes. Interactive Virtual Reality simulations with real time rigid body dynamics and contact interaction allow for RH Compatibility Assessment during the design iterations. This paper explores the use of interactive virtual mock-ups to analyze the RH compatibility of heavy component handling and maintenance. It infers generic maintenance operations from the analysis and proposes improvements to the simulator capabilities

  18. Mechanical circulatory support in pediatrics.

    Science.gov (United States)

    Steffen, Robert J; Miletic, Kyle G; Schraufnagel, Dean P; Vargo, Patrick R; Fukamachi, Kiyotaka; Stewart, Robert D; Moazami, Nader

    2016-05-01

    End-stage heart failure affects thousands of children yearly and mechanical circulatory support is used at many points in their care. Extracorporeal membrane oxygenation supports both the failing heart and lungs, which has led to its use as an adjunct to cardiopulmonary resuscitation as well as in post-operative cardiogenic shock. Continuous-flow ventricular assist devices (VAD) have replaced pulsatile-flow devices in adults and early studies have shown promising results in children. The Berlin paracorporeal pulsatile VAD recently gained U.S. Food and Drug Administration approval and remains the only VAD approved in pediatrics. Failing univentricular hearts and other congenitally corrected lesions are new areas for mechanical support. Finding novel uses, improving durability, and minimizing complications are areas of growth in pediatric mechanical circulatory support.

  19. Life Expectancy and Death by Diseases of the Circulatory System in Patients with Bipolar Disorder or Schizophrenia in the Nordic Countries

    Science.gov (United States)

    Laursen, Thomas Munk; Wahlbeck, Kristian; Hällgren, Jonas; Westman, Jeanette; Ösby, Urban; Alinaghizadeh, Hassan; Gissler, Mika; Nordentoft, Merete

    2013-01-01

    Objective Excess mortality from diseases and medical conditions (natural death) in persons with psychiatric disorders has been extensively reported. Even in the Nordic countries with well-developed welfare systems, register based studies find evidence of an excess mortality. In recent years, cardiac mortality and death by diseases of the circulatory system has seen a decline in all the Nordic countries, but a recent paper indicates that women and men in Denmark, Finland, and Sweden, who had been hospitalised for a psychotic disorder, had a two to three-fold increased risk of dying from a cardiovascular disease. The aim of this study was to compare the mortality by diseases of the circulatory system among patients with bipolar disorder or schizophrenia in the three Nordic countries Denmark, Sweden, and Finland. Furthermore, the aim was to examine and compare life expectancy among these patients. Cause specific Standardized Mortality Rates (SMRs) were calculated for each specific subgroup of mortality. Life expectancy was calculated using Wiesler’s method. Results The SMR for bipolar disorder for diseases of the circulatory system was approximately 2 in all countries and both sexes. SMR was slightly higher for people with schizophrenia for both genders and in all countries, except for men in Denmark. Overall life expectancy was much lower among persons with bipolar disorder or schizophrenia, with life expectancy being from 11 to 20 years shorter. Conclusion Our data show that persons in the Nordic countries with schizophrenia or bipolar disorder have a substantially reduced life expectancy. An evaluation of the reasons for these increased mortality rates should be prioritized when planning healthcare in the coming years. PMID:23826212

  20. The human heart and the circulatory system as an interesting interdisciplinary topic in lessons of physics and biology

    International Nuclear Information System (INIS)

    Volná, M; Látal, F; Kubínek, R; Richterek, L

    2014-01-01

    Many topics which are closely related can be found in the national curriculum of the Czech Republic for physics and biology. One of them is the heart and the circulatory system in the human body. This topic was examined cross curriculum, a teaching module was created and the topic was chosen for our research. The task was to determine if the students of bachelor study are aware of connections between physics and biology within this topic and whether we can help them effectively to describe the corresponding physics phenomena in the human body connected, for example, with a heart attack or with the measurement of blood pressure. In this paper, the heart and the circulatory system are presented as suitable topics for an interdisciplinary teaching module which includes both theoretical and experimental parts. The module was evaluated by a group of first-year undergraduate students of physics at the Faculty of Science, Palacký University. The acquired knowledge was compared with another control group through a test. The highest efficiency of the module was evaluated on the basis of questions that covered the calculation problems. (paper)

  1. Parallel Execution of Functional Mock-up Units in Buildings Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ozmen, Ozgur [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nutaro, James J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); New, Joshua Ryan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-06-30

    A Functional Mock-up Interface (FMI) defines a standardized interface to be used in computer simulations to develop complex cyber-physical systems. FMI implementation by a software modeling tool enables the creation of a simulation model that can be interconnected, or the creation of a software library called a Functional Mock-up Unit (FMU). This report describes an FMU wrapper implementation that imports FMUs into a C++ environment and uses an Euler solver that executes FMUs in parallel using Open Multi-Processing (OpenMP). The purpose of this report is to elucidate the runtime performance of the solver when a multi-component system is imported as a single FMU (for the whole system) or as multiple FMUs (for different groups of components as sub-systems). This performance comparison is conducted using two test cases: (1) a simple, multi-tank problem; and (2) a more realistic use case based on the Modelica Buildings Library. In both test cases, the performance gains are promising when each FMU consists of a large number of states and state events that are wrapped in a single FMU. Load balancing is demonstrated to be a critical factor in speeding up parallel execution of multiple FMUs.

  2. Simulation in full-scale mock-ups: an ergonomics evaluation method?

    DEFF Research Database (Denmark)

    Andersen, Simone Nyholm; Broberg, Ole

    2014-01-01

    This paper presents and exploratory study of four simulation sessions in full-scale mock-ups of future hospital facilities.......This paper presents and exploratory study of four simulation sessions in full-scale mock-ups of future hospital facilities....

  3. ABOUT DIGITAL MOCK-UP FOR MECHANICAL PRODUCTS

    Directory of Open Access Journals (Sweden)

    GHERGHINA George

    2015-06-01

    The digital mock-up of the product is built at a design stage, and is applicable to the whole life-cycle of the product, including design, manufacture, marketing and aftermarket. The digital mock-up could achieve interference check, motion analysis, simulation of performance and manufacturing, technical training, advertising and maintenance, planning etc. The DMU of mechanical products, as important engineering data in a company, is supposed to be able to support all the activities in the whole life-cycle of the product including design, manufacture, marketing and aftermarket

  4. Siloette, Siloe mock-up; Siloette, modele nucleaire de siloe

    Energy Technology Data Exchange (ETDEWEB)

    Delcroix, V; Jeanne, G; Mitault, G; Schulhof, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-07-01

    Siloette is the Siloe mock-up. The main installations are described: various tanks, building, auxiliaries, control systems... Precis ions are given about precautions taken for using spent fuel elements. (authors) [French] Siloette est le modele nucleaire de SILOE. On decrit ses diverses installations: bassins, batiments, auxiliaires, controle... Des precisions sont donnees sur les precautions prises pour y utiliser des elements uses. (auteurs)

  5. Mock ECHO: A Simulation-Based Medical Education Method.

    Science.gov (United States)

    Fowler, Rebecca C; Katzman, Joanna G; Comerci, George D; Shelley, Brian M; Duhigg, Daniel; Olivas, Cynthia; Arnold, Thomas; Kalishman, Summers; Monnette, Rebecca; Arora, Sanjeev

    2018-04-16

    This study was designed to develop a deeper understanding of the learning and social processes that take place during the simulation-based medical education for practicing providers as part of the Project ECHO® model, known as Mock ECHO training. The ECHO model is utilized to expand access to care of common and complex diseases by supporting the education of primary care providers with an interprofessional team of specialists via videoconferencing networks. Mock ECHO trainings are conducted through a train the trainer model targeted at leaders replicating the ECHO model at their organizations. Trainers conduct simulated teleECHO clinics while participants gain skills to improve communication and self-efficacy. Three focus groups, conducted between May 2015 and January 2016 with a total of 26 participants, were deductively analyzed to identify common themes related to simulation-based medical education and interdisciplinary education. Principal themes generated from the analysis included (a) the role of empathy in community development, (b) the value of training tools as guides for learning, (c) Mock ECHO design components to optimize learning, (d) the role of interdisciplinary education to build community and improve care delivery, (e) improving care integration through collaboration, and (f) development of soft skills to facilitate learning. Mock ECHO trainings offer clinicians the freedom to learn in a noncritical environment while emphasizing real-time multidirectional feedback and encouraging knowledge and skill transfer. The success of the ECHO model depends on training interprofessional healthcare providers in behaviors needed to lead a teleECHO clinic and to collaborate in the educational process. While building a community of practice, Mock ECHO provides a safe opportunity for a diverse group of clinician experts to practice learned skills and receive feedback from coparticipants and facilitators.

  6. Characterization of flaws in a tube bundle mock-up for reliability studies

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Bakhtiari, S.

    1997-01-01

    As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubes were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes

  7. Characterization of flaws in a tube bundle mock-up for reliability studies

    International Nuclear Information System (INIS)

    Kupperman, D.S.; Bakhtiari, S.

    1996-10-01

    As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubes were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes

  8. THE THEORETICAL ASTROPHYSICAL OBSERVATORY: CLOUD-BASED MOCK GALAXY CATALOGS

    Energy Technology Data Exchange (ETDEWEB)

    Bernyk, Maksym; Croton, Darren J.; Tonini, Chiara; Hodkinson, Luke; Hassan, Amr H.; Garel, Thibault; Duffy, Alan R.; Mutch, Simon J.; Poole, Gregory B.; Hegarty, Sarah [Centre for Astrophysics and Supercomputing, Swinburne University of Technology, P.O. Box 218, Hawthorn, Victoria, 3122 (Australia)

    2016-03-15

    We introduce the Theoretical Astrophysical Observatory (TAO), an online virtual laboratory that houses mock observations of galaxy survey data. Such mocks have become an integral part of the modern analysis pipeline. However, building them requires expert knowledge of galaxy modeling and simulation techniques, significant investment in software development, and access to high performance computing. These requirements make it difficult for a small research team or individual to quickly build a mock catalog suited to their needs. To address this TAO offers access to multiple cosmological simulations and semi-analytic galaxy formation models from an intuitive and clean web interface. Results can be funnelled through science modules and sent to a dedicated supercomputer for further processing and manipulation. These modules include the ability to (1) construct custom observer light cones from the simulation data cubes; (2) generate the stellar emission from star formation histories, apply dust extinction, and compute absolute and/or apparent magnitudes; and (3) produce mock images of the sky. All of TAO’s features can be accessed without any programming requirements. The modular nature of TAO opens it up for further expansion in the future.

  9. THE THEORETICAL ASTROPHYSICAL OBSERVATORY: CLOUD-BASED MOCK GALAXY CATALOGS

    International Nuclear Information System (INIS)

    Bernyk, Maksym; Croton, Darren J.; Tonini, Chiara; Hodkinson, Luke; Hassan, Amr H.; Garel, Thibault; Duffy, Alan R.; Mutch, Simon J.; Poole, Gregory B.; Hegarty, Sarah

    2016-01-01

    We introduce the Theoretical Astrophysical Observatory (TAO), an online virtual laboratory that houses mock observations of galaxy survey data. Such mocks have become an integral part of the modern analysis pipeline. However, building them requires expert knowledge of galaxy modeling and simulation techniques, significant investment in software development, and access to high performance computing. These requirements make it difficult for a small research team or individual to quickly build a mock catalog suited to their needs. To address this TAO offers access to multiple cosmological simulations and semi-analytic galaxy formation models from an intuitive and clean web interface. Results can be funnelled through science modules and sent to a dedicated supercomputer for further processing and manipulation. These modules include the ability to (1) construct custom observer light cones from the simulation data cubes; (2) generate the stellar emission from star formation histories, apply dust extinction, and compute absolute and/or apparent magnitudes; and (3) produce mock images of the sky. All of TAO’s features can be accessed without any programming requirements. The modular nature of TAO opens it up for further expansion in the future

  10. [Mortality rates of circulatory system diseases and malignant neoplasms in Zagreb population younger than sixty-five--call for alarm].

    Science.gov (United States)

    Vizintin, Marina Polić; Mrcela, Nada Tomasović; Kovacić, Luka

    2012-12-01

    The aim of this work was to analyze the public health indicators for circulatory heart diseases and malignant neoplasms in the population younger than 65 in the City of Zagreb, Croatia, and compare them with the European Union (EU) countries. The purpose was to evaluate the situation and propose the public health preventive measures. The study population were Zagreb citizens aged 0-64 according to the 2001 census. Total Zagreb population was 779145, making 17.6% of total Croatian population. Data from the Croatian Bureau of Statistics and Dr Andrija Stampar Institute of Public Health were used. The standardized 0-64 mortality rates of the selected diseases 2006-2010 were used in the analysis. In 2010, the standardized mortality rates of all analyzed diseases were significantly higher in Zagreb population aged 0-64 than the EU averages except for cervical cancer. In 2010, the mortality rates in Zagreb population aged 0-64 were as follows: circulatory system diseases 61.22, ischemic heart disease 28.99, cerebrovascular diseases 12.51, malignant neoplasms 94.69, tracheal and lung cancer 24.92, breast cancer 21.08 and cervical cancer 2.05. Standardized mortality rates in Zagreb population aged 0-64 for circulatory system were lower than for Croatia (61.22 vs. 63.25), but higher for malignant neoplasms (94.69 vs. 91.2), except for cervical cancer (2.05 vs. 3.14). High standardized mortality rates for the selected diseases in the City of Zagreb, Croatia, were observed. The rates were higher in Zagreb population compared to EU averages except for cervical cancer. This situation urges revision of the public health strategy and implementation of more intensive preventive and screening measures to reduce the risk factors.

  11. Circulatory disease mortality in the Massachusetts tuberculosis fluoroscopy cohort study

    International Nuclear Information System (INIS)

    Little, Mark P.; Zablotska, Lydia B.; Brenner, Alina V.; Lipshultz, Steven E.

    2016-01-01

    High-dose ionizing radiation is associated with circulatory disease. Risks from lower-dose fractionated exposures, such as from diagnostic radiation procedures, remain unclear. In this study we aimed to ascertain the relationship between fractionated low-to-medium dose radiation exposure and circulatory disease mortality in a cohort of 13,568 tuberculosis patients in Massachusetts, some with fluoroscopy screenings, between 1916 and 1961 and follow-up until the end of 2002. Analysis of mortality was in relation to cumulative thyroid (cerebrovascular) or lung (all other circulatory disease) radiation dose via Poisson regression. Over the full dose range, there was no overall radiation-related excess risk of death from circulatory disease (n = 3221; excess relative risk/Gy −0.023; 95 % CI −0.067, 0.028; p = 0.3574). Risk was somewhat elevated in hypertensive heart disease (n = 89; excess relative risk/Gy 0.357; 95 % CI −0.043, 1.030, p = 0.0907) and slightly decreased in ischemic heart disease (n = 1950; excess relative risk/Gy −0.077; 95 % CI −0.130, −0.012; p = 0.0211). However, under 0.5 Gy, there was a borderline significant increasing trend for all circulatory disease (excess relative risk/Gy 0.345; 95 % CI −0.032, 0.764; p = 0.0743) and for ischemic heart disease (excess relative risk/Gy 0.465; 95 % CI, −0.032, 1.034, p = 0.0682). Pneumolobectomy increased radiation–associated risk (excess relative risk/Gy 0.252; 95 % CI 0.024, 0.579). Fractionation of dose did not modify excess risk. In summary, we found no evidence of radiation-associated excess circulatory death risk overall, but there are indications of excess circulatory death risk at lower doses (<0.5 Gy). Although consistent with other radiation-exposed groups, the indications of higher risk at lower doses are unusual and should be confirmed against other data.

  12. Angiographic examinations of the circulatory development of living chick embryos

    International Nuclear Information System (INIS)

    Stoeter, P.; Buchhoecker, M.; Bruzek, W.; Drews, U.; Schulze, K.; Tuebingen Univ.; Tuebingen Univ.

    1980-01-01

    In chick embryos of an age of incubation of 5-14 days, the physiological development of the circulation and the morphological differentation of the arterical system were studied by intravital and postmortal angiography. For the examinations of the living embryos, a special radiographic and injection technique had to be developed. The contrast medium was injected into the umbilical veins and transported by the actions of the embryonic heart. Continuous ECG recordings showed no marked interference of the injections with the cardiac activity. According to the angiographic findings, the circulation is relatively fast within the main arteries, but the capillary perfusion is prolonged and lasts up to several minutes. The average circulatory velocity of the blood stream within the carotid artery increases parallel to the arterial enlargement, whereas the circulatory time decreases and the number of heart beats during the period of carotid opacification does not change to a great extent. By this, a steady transport of gas and nutritional material may be achieved in the growing arterial system. (orig.) [de

  13. Conceptual design of a First Wall mock-up experiment in preparation for the qualification of breeding blanket technologies in the Helium Loop Karlsruhe (HELOKA) facility

    Energy Technology Data Exchange (ETDEWEB)

    Zeile, C., E-mail: christian.zeile@kit.edu [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Abou-Sena, A.; Boccaccini, L.V.; Ghidersa, B.E.; Kang, Q.; Kunze, A. [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Lamberti, L. [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Dipartimento Energia, Politecnico di Torino (Italy); Maione, I.A.; Rey, J.; Weth, A. von der [Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2016-11-01

    Highlights: • Experiment in preparation for the qualification of Breeding Blanket technologies in HELOKA facility is proposed. • Experimental capabilities, instrumentation of the mock-up and experimental program are presented. • Design and manufacturing of the mock-up is described. • Design of modular attachment system to obtain different stress levels and distributions on the mock-up is discussed. - Abstract: An experimental program based on a First Wall mock-up is presented as preparation for the qualification of breeding blanket mock-ups at high heat flux in the Helium Loop Karlsruhe (HELOKA) facility. Two objectives of the experimental program have been defined: testing of the experimental setup and a first validation of FE models. The design and manufacturing of mock-up representing about 1/3 of the heated zone of an ITER Test Blanket Module (TBM) First Wall is discussed. A modular attachment system concept has been developed for the fixation of the mock-up in order to be able to generate different stress distributions and levels on the plate, which is confirmed by thermo-mechanical analyses. The HELOKA facility is able to provide a TBM relevant helium cooling system and to generate the required surface heat flux by an electron beam gun. An installed IR camera can be used to measure the temperature distribution on the surface.

  14. Thermo-mechanical tests of a CFC divertor mock-up

    International Nuclear Information System (INIS)

    Cardella, A.; Akiba, M.; Duwe, R.; Di Pietro, E.; Suzuki, S.; Satoh, K.; Reheis, N.

    1994-01-01

    Thermo-mechanical tests have been performed on a divertor mock-up consisting of a metallic tube armoured with five carbon fibre composite tiles. The tube is inserted the tiles and brazed with TiCuSil braze (monoblock concept). The tube material is TZM, a molybdenum alloy, and the armour material is SEP CARB N112, a high conductivity carbon-carbon composite. Using special surface preparation consisting of laser drilling, small (≅ 500 μm) holes in the composite have been made to increase the surface wetted by the braze and the resistance. The mock-up has been tested at the JAERI 400 kW electron beam test facility JEBIS. The aim of the test was to assess the performance of the mock-up in screening and thermal fatigue tests with particular attention to the behaviour of the armour to heat sink joint. (orig.)

  15. Harmonic Maass forms and mock modular forms

    CERN Document Server

    Bringmann, Kathrin; Ono, Ken

    2017-01-01

    Modular forms and Jacobi forms play a central role in many areas of mathematics. Over the last 10-15 years, this theory has been extended to certain non-holomorphic functions, the so-called "harmonic Maass forms". The first glimpses of this theory appeared in Ramanujan's enigmatic last letter to G. H. Hardy written from his deathbed. Ramanujan discovered functions he called "mock theta functions" which over eighty years later were recognized as pieces of harmonic Maass forms. This book contains the essential features of the theory of harmonic Maass forms and mock modular forms, together with a wide variety of applications to algebraic number theory, combinatorics, elliptic curves, mathematical physics, quantum modular forms, and representation theory.

  16. Adequacy of the analysis of mock-up control rod experiment with FCA

    International Nuclear Information System (INIS)

    Mizoo, Nobutatsu; Nakano, Masafumi

    1977-07-01

    A method of numerical analysis has been investigated for the mock-up control rod experiment of FCA VII-1 assembly constructed as the engineering mock-up of prototype fast breeder reactor MONJU. The results of criticality and B 4 C mock-up control rod worths analysis for the assembly are described in comparison with the experimental ones. The tendency of the C/E value with 10 B enrichment and the interaction effect of the multiple rods array was also examined. Reactivities and the mock-up rods worths were obtained with the X-Y geometry six groups diffusion theory. Twelve kinds of the mock-up rods with different 10 B contents and/or enrichments were used in the experiment; effective cross-sections are provided for each rod by calculation using the collision probability method. Criticality of VII-1 90Z assembly is underestimated for 3 reference critical configurations, ranging from -0.65%Δk/k to -0.77%Δk/k. The C/E values at core center for 12 kinds of B 4 C mock-up rods range from 1.03 to 1.09. The overestimate of the rod worth increases with macroscopic absorption cross-section of the rod region. The C/E values for 24 different arrays of the mock-up rods ranging from single rod to five rods lie between 1.04 and 1.08. The C/E value tends to decrease with increase in the number of rods inserted, the values for five rods arrays being about 4% lower than those for single rod arrays. The calculated interaction effects of the multiple rods arrays are slightly more negative than the experimental ones. (auth.)

  17. Team training using full-scale reactor coolant pump seal mock-ups

    International Nuclear Information System (INIS)

    McDonald, T.J.; Hamill, R.W.

    1987-01-01

    The use of full-scale reactor coolant pump (RCP) seal mock-ups has greatly enhanced Northeast Utilities' ability to effectively utilize the team training approach to technical training. With the advent of the Institute of Nuclear Power Operations accreditation come a new emphasis and standards for the integrated training of plant engineering personnel, maintenance mechanics, quality control personnel, and health physics personnel. The results of purchasing full-scale RCP mock-ups to pilot the concept of team training have far exceeded expectations and cost-limiting factors. The initial training program analysis identified RCP seal maintenance as a task that required training for maintenance department personnel. Due to radiation exposure considerations and the unavailability of actual plant equipment for training purposes, the decision was made to procure a mock-up of an RCP seal assembly and housing. This mock-up was designed to facilitate seal cartridge removal, disassembly, assembly, and installation, duplicating all internal components of the seal cartridge and housing area in exact detail

  18. Electron beam irradiation experiments of monoblock divertor mock-up

    International Nuclear Information System (INIS)

    Satoh, Kazuyoshi; Akiba, Masato; Araki, Masanori; Suzuki, Satoshi; Yokoyama, Kenji; Smid, I.; Cardella, A.; Duwe, R.; Di Pietro, E.

    1993-03-01

    It is one of the key issues for ITER to develop the divertor plate. Electron beam irradiation tests were carried out on a NET divertor mock-up using JEBIS at JAERI under a collaboration between The NET team, JAERI and KFA Juelich. Screening tests (maximum heat flux of 23 MW/m 2 ) and thermal cycling tests (18 MW/m 2 , 30s, 1000cycle) were carried out. As a result of the screening tests, the erosion caused by sublimation of C/C was observed on the surface of armor tile. No serious damage such as cracks or detachments, however, were found. As a result of the thermal cycling tests, no major damage was detected on the C/C surface. However cooling time constant of the divertor mock-up increased over 600cycle. Therefore it implies that some defects would occur at the brazing interface of the divertor mock-up. (author)

  19. CHF: circulatory homeostasis gone awry.

    Science.gov (United States)

    Weber, Karl T; Burlew, Brad S; Davis, Richard C; Newman, Kevin P; D'Cruz, Ivan A; Hawkins, Ralph G; Wall, Barry M; Parker, Robert B

    2002-01-01

    The role of the renin-angiotensin-aldosterone system (RAAS) is integral to salt and water retention, particularly by the kidneys. Over time, positive sodium balance leads first to intra- and then to extravascular volume expansion, with subsequent symptomatic heart failure. This report examines the role of the RAAS in regulating a less well recognized component essential to circulatory homeostasis--central blood volume. The regulation of central blood volume draws on integrative cardiorenal physiology and a key role played by the RAAS in its regulation. In presenting insights into the role of the RAAS in regulating central blood volume, this review also addresses other sodium-retaining states with a predisposition to edema formation, such as cirrhosis and nephrosis. (c)2002 CHF, Inc

  20. Role of irradiation reactor mock-ups

    International Nuclear Information System (INIS)

    Casali, F.; Cerles, J.M.; Debrue, J.

    1977-01-01

    A survey is given of the utilization of low power facilities in support to irradiation reactor experiments. The BRO2, ISIS and RB3 facilities are described as neutronic mock-ups of the BR2, OSIRIS and ESSOR reactors respectively

  1. Development of control technology for HTTR hydrogen production system with mock-up test facility

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Inaba, Yoshitomo; Nishihara, Tetsuo; Takeda, Tetsuaki; Hayashi, Koji; Takada, Shoji; Inagaki, Yoshiyuki

    2006-01-01

    The Japan Atomic Energy Agency has been planning the demonstration test of hydrogen production with the High Temperature Engineering Test Reactor (HTTR). In a HTTR hydrogen production system (HTTR-H2), it is required to control a primary helium temperature within an allowable value at a reactor inlet to prevent a reactor scram. A cooling system for a secondary helium with a steam generator (SG) and a radiator is installed at the downstream of a chemical rector in a secondary helium loop in order to mitigate the thermal disturbance caused by the hydrogen production system. Prior to HTTR-H2, the simulation test with a mock-up test facility has been carried out to establish the controllability on the helium temperature using the cooling system against the loss of chemical reaction. It was confirmed that the fluctuations of the helium temperature at chemical reactor outlet, more than 200 K, at the loss of chemical reaction could be successfully mitigated within the target of ±10 K at SG outlet. A dynamic simulation code of the cooling system for HTTR-H2 was verified with the obtained test data

  2. The circulatory system: blood procurement, AIDS, and the social body in China.

    Science.gov (United States)

    Erwin, Kathleen

    2006-06-01

    The market for blood thrived in China for more than a decade, preying on rural villagers desperate for cash. Profit motives and unhygienic collection created an AIDS epidemic, where now up to 80 percent of adults in some villages are HIV infected. Today, illegal blood banks continue to operate in some areas. Moreover, better screening and blood testing do little to address the underlying cultural reluctance to give blood. This article examines what is at stake for blood donors in the circulation of blood through both the physical and the social bodies in China today. I argue that public health and social policy solutions require consideration of the symbolic meanings of blood and the body, kin relations, and gift exchange. China's HIV-contaminated blood procurement crisis demands a critical reexamination of the hidden processes embedded in a "circulatory system" that has inseparably bound the "gift of life" and a "commodity of death".

  3. In-pile testing of ITER first wall mock-ups at relevant thermal loading conditions

    Science.gov (United States)

    Litunovsky, N.; Gervash, A.; Lorenzetto, P.; Mazul, I.; Melder, R.

    2009-04-01

    The paper describes the experimental technique and preliminary results of thermal fatigue testing of ITER first wall (FW) water-cooled mock-ups inside the core of the RBT-6 experimental fission reactor (RIAR, Dimitrovgrad, Russia). This experiment has provided simultaneous effect of neutron fluence and thermal cycling damages on the mock-ups. A PC-controlled high-temperature graphite ohmic heater was applied to provide cyclic thermal load onto the mock-ups surface. This experiment lasted for 309 effective irradiation days with a final damage level (CuCrZr) of 1 dpa in the mock-ups. About 3700 thermal cycles with a heat flux of 0.4-0.5 MW/m 2 onto the mock-ups were realized before the heater fails. Then, irradiation was continued in a non-cycling mode.

  4. Tests of load resilient matching procedures for the ITER ICRH system on a mock-up and layout proposals

    International Nuclear Information System (INIS)

    Dumortier, P.; Lamalle, P.; Messiaen, A.; Vervier, M.

    2006-01-01

    The ICRH antenna of ITER consists of an array of 24 radiating straps and must radiate 20 MW with resilience to load variations due to the ELMs. Because of its compactness the mutual coupling effects between the straps are far from negligible. Moreover they considerably increase the difficulty of matching and lead to coupling between the generators. Different external matching system layouts are under consideration. A reduced scale (1/5) mock-up loaded by a movable water tank is used for their experimental investigation. A first layout using full passive power distribution among the straps and a single matching circuit with one '' Conjugate-T '' (CT) or one hybrid has already been successfully tested. Its drawbacks are the difficulty of changing the toroidal phasing and the use of a single 20 MW feeding line section. In this paper we describe the mock-up tests of a second layout based on two 10 MW CT circuits, and allowing switching between heating or current drive phasings without any hardware modification. Two decouplers are used to minimize the effect of mutual coupling on matching. A robust four-parameter CT matching procedure has been developed based on adjusting the two first parameters - the positions of the line stretchers in the CT branches - of each CT in vacuum conditions (this is done once for all for each frequency). High load resilience, i.e. a VSWR remaining < 1.5 for an 8-fold increase of antenna resistance, can be obtained for the 4 toroidal phasing configurations considered: (0π/2π3π/2), (0-π/2-π-3π/2), (00ππ) and (0ππ0). The change of phasing only requires the adjustment of the phase difference between the two power sources and of the two last parameters (stub and line stretcher in the common line) of each of the two CT circuits. These properties have first been derived from the experimental scattering matrix of the antenna array and are verified by reflection measurements on the mock-up. Feedback control of the phasing and the last two

  5. Pulmonary circulatory effects of norepinephrine in newborn infants with persistent pulmonary hypertension.

    Science.gov (United States)

    Tourneux, Pierre; Rakza, Thameur; Bouissou, Antoine; Krim, Gérard; Storme, Laurent

    2008-09-01

    To evaluate the respiratory and the pulmonary circulatory effects of norepinephrine in newborn infants with persistent pulmonary hypertension (PPHN)-induced cardiac dysfunction. Inclusion criteria were: 1) Newborn infants >35 weeks gestational age; 2) PPHN treated with inhaled nitric oxide; and 3) symptoms of circulatory failure despite adequate fluid resuscitation. Lung function and pulmonary hemodynamic variables assessed with Doppler echocardiography were recorded prospectively before and after starting norepinephrine. Eighteen newborns were included (gestational age: 37 +/- 3 weeks; birth weight: 2800 +/- 700 g). After starting norepinephrine, systemic pressure and left ventricular output increased respectively from 33 +/- 4 mm Hg to 49 +/- 4 mm Hg and from 172 +/- 79 mL/kg/min to 209+/-90 mL/kg/min (P ventilatory variables have not been changed, the post-ductal transcutaneous arterial oxygen saturation increased from 89% +/- 1% to 95% +/- 4%, whereas the oxygen need decreased from 51% +/- 24% to 41% +/- 20% (P newborn infants with PPHN through a decrease in pulmonary/systemic artery pressure ratio and improved cardiac performance.

  6. Relation between awareness of circulatory disorders and smoking in a general population health examination

    Directory of Open Access Journals (Sweden)

    Völzke Henry

    2006-02-01

    Full Text Available Abstract Background Little is known about proportions of smokers who maintain smoking after they are aware of a circulatory disorder. The goal was to analyze the extent to which the number of circulatory disorders may be related to being a current smoker. Methods Cross-sectional survey study with a probability sample of residents in Germany investigated in health examination centers. Questionnaire data of 3,778 ever smoking participants aged 18 – 79 were used, questions included whether the respondent had ever had hypertension, myocardial infarction, other coronary artery disease, heart failure, stroke, other cerebrovascular disease, peripheral vascular disease, and venous thrombosis. Logistic regression was calculated for circulatory disorders and their number with current smoking as the dependent variable, and odds ratios (OR are presented adjusted for physician contact, inpatient treatment, smoking cessation counseling, heavy smoking, exercise, overweight and obesity, school education, sex and age. Results Among ever smokers who had 1 circulatory disorder, 52.1 % were current smokers and among those who reported that they had 3 or more circulatory disorders 28.0 % were current smokers at the time of the interview. The adjusted odds of being a current smoker were lower for individuals who had ever smoked in life and had 2 or more central circulatory disorders, such as myocardial infarction, heart failure or stroke, than for ever smokers without central circulatory disorder (2 or more disorders: adjusted OR 0.6, 95 % confidence interval, CI, 0.4 to 0.8. Conclusion Among those with central circulatory disorders, there is a substantial portion of individuals who smoke despite their disease. The data suggest that only a portion of smokers among the general population seems to be discouraged from smoking by circulatory disorders or its accompanying cognitive or emotional processes.

  7. Plasma coatings of nitrogen polymers on metal prostheses of the circulatory system

    International Nuclear Information System (INIS)

    Gomez J, L. M.

    2016-01-01

    This work has a study about the synthesis of poly aniline, poly allylamine and poly pyrrole doped with iodine onto metallic surfaces similar to stents for the circulatory system. Ar, water and hydrogen peroxide plasmas were used for eroding, conditioning and synthesizing polymers that potentially reduce some rejection reactions when stents are implanted in the human body. Stents are small metallic meshes that applied inside collapsed arteries or veins enlarge the diameter and restore the blood flow, however the metallic surfaces usually cause rejection reactions that obstruct the veins again. To give solutions to this problem, in this work is studied the synthesis of biocompatible polymer coatings on the stents that resist the blood flow forming a biocompatible interface between metal and blood. The metallic substrates were eroded and chemically prepared with Ar, H_2O and/or H_2O_2 glow discharges on which the polymers were synthesized by plasma. The coatings were morphologically characterized by optical, scanning electron and atomic force microscopy, the chemical structure was studied by infrared and photoelectron X-ray spectroscopy. The hydrophilicity was studied measuring the advance static contact angle and the adhesion was evaluated indirectly with scanning electron microscopy after two months submerged in buffered phosphate solutions. The results indicate that the polymers grew following the superficial morphology; that the conditioning with Ar ions erode the substrates and that the conditioning with H_2O or H_2O_2 erodes and activates the surface generating oxygen bridges which help in the polymer-metal adhesion. The chemical structure of the polymeric coatings contain crosslinked structures that correspond to links between monomers with the participation of all atoms, states that suggest monomer fragmentation and oxidation and states that indicate oxygen bridges in the polymers. The coatings had contact angles close to 90 degrees where is located the line

  8. The making of a mock-up

    DEFF Research Database (Denmark)

    Rosenqvist, Tanja Schultz; Heimdal, Elisabeth Jacobsen

    2011-01-01

    As part of a research project about user involvement in textile design we have carried out two Design:Labs (Binder & Brandt 2008) engaging different stakeholders in designing textile products for Danish hospital environments. In this paper we follow a mock-up session done as part of the second...

  9. The utility of mock oral examinations in preparation for the American Board of Surgery certifying examination.

    Science.gov (United States)

    Higgins, Rana M; Deal, Rebecca A; Rinewalt, Daniel; Hollinger, Edward F; Janssen, Imke; Poirier, Jennifer; Austin, Delores; Rendina, Megan; Francescatti, Amanda; Myers, Jonathan A; Millikan, Keith W; Luu, Minh B

    2016-02-01

    Determine the utility of mock oral examinations in preparation for the American Board of Surgery certifying examination (ABS CE). Between 2002 and 2012, blinded data were collected on 63 general surgery residents: 4th and 5th-year mock oral examination scores, first-time pass rates on ABS CE, and an online survey. Fifty-seven residents took the 4th-year mock oral examination: 30 (52.6%) passed and 27 (47.4%) failed, with first-time ABS CE pass rates 93.3% and 81.5% (P = .238). Fifty-nine residents took the 5th-year mock oral examination: 28 (47.5%) passed and 31 (52.5%) failed, with first-time ABS CE pass rates 82.1% and 93.5% (P = .240). Thirty-eight responded to the online survey, 77.1% ranked mock oral examinations as very or extremely helpful with ABS CE preparation. Although mock oral examinations and ABS CE passing rates do not directly correlate, residents perceive the mock oral examinations to be helpful. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Blanket Cooling Plates Mock-ups Manufactured in different Diffusion Weld Setup

    International Nuclear Information System (INIS)

    Von Der Weth, A.; Aktaa, J.

    2007-01-01

    Full text of publication follows: The breeding blanket box is considered as one of the most important components of a future fusion power plant. It will be assembled by so called cooling plates (CP) with a system of internal cooling channels. Such a CP is produced by two symmetric half pieces with half milled-in channels. Both pieces will be joined by a diffusion weld (DW) process. Within recent years a two step DW process for different EUROFER batches has been developed. It has been first applied to small laboratory scaled samples with dimensions of 25 mm x 30 mm x 40 mm. Then the DW process had then been successfully transferred to so called compact mock ups which are small CPs with dimensions of 67 mm x 70 mm x 50 mm. As third step this process has been used to manufacture a CP (465 mm x 205 mm x 50 mm) of a breeder unit in an industrial uniaxial diffusion weld setup. This paper treats the manufacturing sequence of a cooling plate and a first wall mock up in an industrial hot isostatic pressing (HIP) setup. The firstly laboratory specimens scaled diffusion weld process has been adjusted to different cooling channel dimensions and a different DW setup. The weld quality is investigated by tensile and Charpy impact testing. This allows comparison of the weld quality of mock ups welded in different DW setups. (authors)

  11. Ramanujan's mock theta functions.

    Science.gov (United States)

    Griffin, Michael; Ono, Ken; Rolen, Larry

    2013-04-09

    In his famous deathbed letter, Ramanujan introduced the notion of a mock theta function, and he offered some alleged examples. Recent work by Zwegers [Zwegers S (2001) Contemp Math 291:268-277 and Zwegers S (2002) PhD thesis (Univ of Utrecht, Utrecht, The Netherlands)] has elucidated the theory encompassing these examples. They are holomorphic parts of special harmonic weak Maass forms. Despite this understanding, little attention has been given to Ramanujan's original definition. Here, we prove that Ramanujan's examples do indeed satisfy his original definition.

  12. HTTR hydrogen production system. Structure and main specifications of mock-up test facility (Contract research)

    International Nuclear Information System (INIS)

    Kato, Michio; Aita, Hideki; Inagaki, Yoshiyuki; Hayashi, Koji; Ohashi, Hirofumi; Sato, Hiroyuki; Iwatsuki, Jin; Takada, Shoji; Inaba, Yoshitomo

    2007-03-01

    The mock-up test facility was fabricated to investigate performance of the steam generator for mitigation of the temperature fluctuation of helium gas and transient behavior of the hydrogen production system for HTTR and to obtain experimental data for verification of a dynamic analysis code. The test facility has an approximate hydrogen production capacity of 120Nm 3 /h and the steam reforming process of methane; CH 4 +H 2 O=3H 2 +CO, was used for hydrogen production of the test facility. An electric heater was used as a heat source instead of the reactor in order to heat helium gas up to 880degC (4MPa) at the chemical reactor inlet which is the same temperature as the HTTR hydrogen production system. Fabrication of the test facility was completed in February in 2002, and seven cycle operations were carried out from March in 2002 to December in 2004. This report describes the structure and main specifications of the test facility. (author)

  13. Generation of OH Radical by Ultrasonic Irradiation in Batch and Circulatory Reactor

    Science.gov (United States)

    Fang, Yu; Shimizu, Sayaka; Yamamoto, Takuya; Komarov, Sergey

    2018-03-01

    Ultrasonic technology has been widely investigated in the past as one of the advance oxidation processes to treat wastewater, in this process acoustic cavitation causes generation of OH radical, which play a vital role in improving the treatment efficiency. In this study, OH radical formation rate was measured in batch and circulatory reactor by using Weissler reaction at various ultrasound output power. It is found that the generation rate in batch reactor is higher than that in circulatory reactor at the same output power. The generation rate tended to be slower when output power exceeds 137W. The optimum condition for circulatory reactor was found to be 137W output and 4L/min flow rate. Results of aluminum foil erosion test revealed a strong dependence of cavitation zone length on the ultrasound output power. This is assumed to be one of the reasons why the generation rate of HO radicals becomes slower at higher output power in circulatory reactor.

  14. Fabrication of ITER first wall mock-ups with beryllium armour

    International Nuclear Information System (INIS)

    Mohri, K.; Nomoto, Y.; Uda, M.; Enoeda, M.; Akiba, M.

    2004-01-01

    This paper presents the fabric ability development for the ITER first wall through the fabrication of a real size first wall panel mock-up without beryllium armor and a partial mock-up of the first wall panel with beryllium armor. Microscopic observation and mechanical test of the hot isostatic pressed Be/Cu-alloy joints were also performed of which results showed good bond ability of the joints. Finally the fabrication procedure of the ITER first wall panel has been established. (author)

  15. Multidisciplinary approach to radiation late effects in the brain circulatory system: First results

    International Nuclear Information System (INIS)

    Keyeux, A.J.M.; Reinhold, H.S.; Gerber, G.B.; Maisin, J.R.; Reyners, H.; Gianfelici de Reyners, E.; Calvo, W.

    1976-01-01

    Although acute vascular damage and the early functional impairment of the central nervous system has been studied relatively frequently, the pathophysiological mechanisms of late radiation effects and their relevance to vascular damage, are less well investigated and are poorly understood. As the possibility of later radiation damage is a factor which limits the therapist in the radiation dose, he can give to effect a local tumour cure, it is essential that the mechanisms and importance of vascular irradiation damage be determined before late effects can either be treated or avoided. In view of the inconclusive results obtained by previous authors, it was felt that a multidisciplinary approach might better be suited to solve this problem. Thus, in 1973 a research project was initiated by EULEP to investigate the origins and consequences of radiation induced vascular changes after local irradiation of the brain. In this preliminary report, data on morphological, circulatory and biochemical parameters are presented and discussed. (GC)

  16. Molecular mechanisms of circulatory dysfunction in cirrhotic portal hypertension

    Directory of Open Access Journals (Sweden)

    Hsin-Ling Ho

    2015-04-01

    Full Text Available Acute or chronic insults to the liver are usually followed by a tissue repairing process. Unfortunately, this action, in most cases, is not effective enough to restore the normal hepatic structure and function. Instead, fibrogenesis and regenerative nodules formation ensue, which are relatively nonfunctioning. The common final stage of the process is liver cirrhosis with increased intrahepatic resistance to portal venous blood flow. Throughout the entire course, the extrahepatic circulatory dysfunction, including increased splanchnic blood flow, elevated portal venous blood flow and pressure, decreased splanchnic and peripheral vascular resistance, tachycardia, and increased cardiac output, are noted and denoted as portal hypertension with hyperdynamic circulatory dysfunction. When such a condition is established, patients may suffer from fatal complications such as gastroesophageal variceal hemorrhage, hepatic encephalopathy, or hepatorenal syndrome. The cause of such a circulatory dysfunction is not fully elucidated. Nevertheless, clarification of the pathophysiology definitely contributes to the control of portal hypertension-related complications. Herein, the molecular mechanism of this intriguing disaster is reviewed and discussed.

  17. Mock-up qualification and prototype manufacture for ITER current leads

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tingzhi, E-mail: tingszhou@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Lu, Kun; Ran, Qingxiang; Ding, Kaizhong; Feng, Hansheng; Wu, Huan; Liu, Chenglian; Song, Yuntao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China); Niu, Erwu [CNDA, Ministry of Science and Technology, Beijing (China); Bauer, Pierre; Devred, Arnaud [Magnet Division, ITER Organization, Cadarache (France)

    2015-10-15

    Highlights: • Vacuum brazing and electron beam welding qualification. • Machine and assembly strategy of fin type heat exchanger. • Soldering and joint resistance test of superconducting joint. • Pre-preg technology with vacuum bag on insulation. - Abstract: Three types of high temperature superconducting current leads (HTSCL) are designed to carry 68 kA, 55 kA or 10 kA to the ITER magnets. Before the supply of the HTS current lead series, the design and manufacturing process is qualified through mock-ups and prototypes. Seven mock-ups, representing the critical technologies of the current leads, were built and tested successfully in the Institute of Plasma Physics of the Chinese Academy of Sciences (ASIPP) in 2013. After the qualification some design features of the HTS leads were updated. This paper summarizes the qualification through mock-ups. In 2014 ASIPP started the manufacture of the prototypes. The preparation and manufacturing process are also described.

  18. Mock Trials versus Management or Litigation-Driven Models of Business Law Instruction

    Science.gov (United States)

    Gershuny, Pamela; McAllister, Charles; Rainey, Carolyn

    2012-01-01

    This study was designed to gain a greater understanding of the learning outcomes associated with the mock trial as an active teaching method. Participating in a product liability mock trial presents students with the complex interplay of administrative regulations and common law. As in real life, the harsh constraints of time pressures, less than…

  19. High heat flux test of tungsten brazed mock-ups developed for KSTAR divertor

    Energy Technology Data Exchange (ETDEWEB)

    Song, J.H. [National Fusion Research Institute, Daejeon (Korea, Republic of); Kim, K.M., E-mail: kyungmin@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Hong, S.H.; Kim, H.T.; Park, S.H.; Park, H.K.; Ahn, H.J. [National Fusion Research Institute, Daejeon (Korea, Republic of); Kim, S.K.; Lee, D.W. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-11-01

    The tungsten (W) brazed flat type mock-up which consists of W, OFHC-Cu (oxygen-free high conductive copper) and CuCrZr alloy has been designed for KSTAR divertor in preparation for KSTAR upgrade with 17 MW heating power. For verification of the W brazed mock-up, the high heat flux test is performed at KoHLT-EB (Korea High Heat Load Test Facility-Electron Beam) in KAERI (Korea Atomic Energy Research Institute). Three mock-ups are tested for several thousand thermal cycles with absorbed heat flux up to 5 MW/m{sup 2} for 20 s duration. There is no evidence of the failure at the bonding joints of all mock-ups after HHF test. Finite element analysis (FEA) is performed to interpret the result of the test. As a result, it is considered that the local area in the water is in the subcooled boiling regime.

  20. Long-term Mechanical Circulatory Support System reliability recommendation by the National Clinical Trial Initiative subcommittee.

    Science.gov (United States)

    Lee, James

    2009-01-01

    The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.

  1. Project W-314 performance mock-up test procedure

    International Nuclear Information System (INIS)

    CARRATT, R.T.

    1999-01-01

    The purpose of this Procedure is to assist construction in the pre-operational fabrication and testing of the pit leak detection system and the low point drain assembly by: (1) Control system testing of the pit leak detection system will be accomplished by actuating control switches and verifying that the control signal is initiated, liquid testing and overall operational requirements stated in HNF-SD-W314-PDS-003, ''Project Development Specification for Pit Leak Detection''. (2) Testing of the low point floor drain assembly by opening and closing the drain to and from the ''retracted'' and ''sealed'' positions. Successful operation of this drain will be to verify that the seal does not leak on the ''sealed'' position, the assembly holds liquid until the leak detector actuates and the assembly will operate from on top of the mock-up cover block

  2. Android Robot-Mediated Mock Job Interview Sessions for Young Adults with Autism Spectrum Disorder: A Pilot Study.

    Science.gov (United States)

    Kumazaki, Hirokazu; Warren, Zachary; Corbett, Blythe A; Yoshikawa, Yuichiro; Matsumoto, Yoshio; Higashida, Haruhiro; Yuhi, Teruko; Ikeda, Takashi; Ishiguro, Hiroshi; Kikuchi, Mitsuru

    2017-01-01

    The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18-25 years) with autism spectrum disorder (ASD) were randomized to participate either in a mock job interview training with our android robot system ( n  = 7) or a self-paced review of materials about job-interviewing skills ( n  = 8). Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning.

  3. Android Robot-Mediated Mock Job Interview Sessions for Young Adults with Autism Spectrum Disorder: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Hirokazu Kumazaki

    2017-09-01

    Full Text Available The feasibility and preliminary efficacy of an android robot-mediated mock job interview training in terms of both bolstering self-confidence and reducing biological levels of stress in comparison to a psycho-educational approach human interview was assessed in a randomized study. Young adults (ages 18–25 years with autism spectrum disorder (ASD were randomized to participate either in a mock job interview training with our android robot system (n = 7 or a self-paced review of materials about job-interviewing skills (n = 8. Baseline and outcome measurements of self-reported performance/efficacy and salivary cortisol were obtained after a mock job interview with a human interviewer. After training sessions, individuals with ASD participating in the android robot-mediated sessions reported marginally improved self-confidence and demonstrated significantly lower levels of salivary cortisol as compared to the control condition. These results provide preliminary support for the feasibility and efficacy of android robot-mediated learning.

  4. The Effect of Mock Tests on Iranian EFL learners’ Test Scores

    Directory of Open Access Journals (Sweden)

    Hossein Khodabakhshzadeh

    2016-07-01

    Full Text Available The effect of using tests in test preparation courses has been subject to debate. While some scholars such as Yang and Badger (2015 believe it is a cause of positive washback effect, others argue that this issue is tentative and context-bound (Green, 2007. Therefore, this study investigated the effect of using Mock tests in International English Language Testing System (IELTS preparation courses on students’ overall IELTS scores. Fifty one IELTS students were selected non-randomly through the quota sampling approach out of 76 students at Mahan Language Institute in Birjand, Iran.  These participants were distributed into Group 1 (n=25 and Group 2 (n=26. A complete IELTS test was administered to ensure that the Groups were homogeneous and to serve as pretest. After 10 sessions of intervention, a different IELTS test was administered as posttest. The results of between subject analysis through independent samples t-test revealed that using Mock tests in the IELTS preparation courses can positively affect the participants scores on IELTS exam. Pedagogical implications are discussed.

  5. Study on control characteristics for HTTR hydrogen production system with mock-up test facility

    International Nuclear Information System (INIS)

    Inaba, Yoshitomo; Ohashi, Hirofumi; Nishihara, Tetsuo; Sato, Hiroyuki; Inagaki, Yoshiyuki; Takeda, Tetsuaki; Hayashi, Koji; Takada, Shoji

    2005-01-01

    The Japan Atomic Energy Research Institute has a demonstration test plan of a hydrogen production system by steam reforming of methane coupling with the High-Temperature Engineering Test Reactor (HTTR). Prior to the coupling of a hydrogen production plant with the HTTR, simulation tests with a mock-up test facility of the HTTR hydrogen production system (HTTR-H2) is underway. The test facility is a 1/30-scale of the HTTR-H2 and simulates key components downstream from an intermediate heat exchanger of the HTTR. The main objective of the simulation tests is the establishment and demonstration of control technology, focusing on the mitigation of a thermal disturbance to the reactor by a steam generator (SG) and on the controllability of the pressure difference between the helium and process gases at the reaction tube in a steam reformer (SR). It was confirmed that the fluctuation of the outlet helium gas temperature at the SG and the pressure difference in the SR can be controlled within the allowable range for the HTTR-H2 in the case of the system controllability test for the fluctuation of chemical reaction. In addition, a dynamic simulation code for the HTTR-H2 was verified with the obtained test data

  6. Aortic arch reconstruction: deep and moderate hypothermic circulatory arrest with selective antegrade cerebral perfusion.

    Science.gov (United States)

    Wu, YanWen; Xiao, LiQiong; Yang, Ting; Wang, Lei; Chen, Xin

    2017-07-01

    To compare the effects of moderate and deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (SACP) during aortic arch surgery in adult patients and to offer the evidence for the detection of the temperature which provides best brain protection in the subjects who accept aortic arch reconstruction surgery. A total of 109 patients undergoing surgery of the aortic arch were divided into the moderate hypothermic circulatory arrest group (Group I) and the deep hypothermic circulatory arrest group (Group II). We recorded the data of the patients and their cardiopulmonary bypass (CPB) time, aortic clamping time, SACP time and postoperative anesthetized recovery time, tracheal intubation time, time in the intensive care unit (ICU) and postoperative neurologic dysfunction. Patient characteristics were similar in the two groups. There were four patients who died in Group II and 1 patient in Group I. There were no significant differences in aortic clamping time of each group (111.4±58.4 vs. 115.9±16.2) min; SACP time (27.4±5.9 vs. 23.5±6.1) min of the moderate hypothermic circulatory arrest group and the deep hypothermic circulatory arrest group; there were significant differences in cardiopulmonary bypass time (207.4±20.9 vs. 263.8±22.6) min, postoperative anesthetized recovery time (19.0±11.1 vs. 36.8±25.3) hours, extubation time (46.4±15.1 vs. 64.4±6.0) hours; length of stay in the intensive care unit (ICU) (4.7±1.7 vs. 8±2.3) days and postoperative neurologic dysfunction in the two groups. Compared to deep hypothermic circulatory arrest, moderate hypothermic circulatory arrest can provide better brain protection and achieve good clinical results.

  7. Benefits of mock oral examinations in a multi-institutional consortium for board certification in general surgery training.

    Science.gov (United States)

    Subhas, Gokulakkrishna; Yoo, Stephen; Chang, Yeon-Jeen; Peiper, David; Frikker, Mark J; Bouwman, David L; Silbergleit, Allen; Lloyd, Larry R; Mittal, Vijay K

    2009-09-01

    The Southeast Michigan Center for Medical Education (SEMCME) is a consortium of teaching hospitals in the Greater Detroit metropolitan area. SEMCME pools its resources for several educational means, including mock oral board examinations. The educational and cost benefits to mock oral examinations on a multi-institutional basis in preparation for the American Board of Surgery (ABS) certifying examination were analyzed. Ten-year multi-institution data from the mock oral examinations were correlated with ABS certifying examination pass rates. Mock oral examination scores were available for 107 of 147 graduates, which included 12 candidates who failed their certifying examination on the first attempt (pass rate = 89%). Four of 31 examinees who had a low score (4.9 or less) in their mock oral exams failed their certifying examination in their first attempt. The cost of running the mock examination was low (approximately $35/resident for 50 residents). When graduates from the last 10 years were surveyed, the majority of respondents believed that the mock oral examination helped in their success and with their preparation for the certifying examination. Thus, the many benefits of administering the examination with the resources of a consortium of hospitals result in the accurate reproduction of real-life testing conditions with reasonable overall costs per resident.

  8. Mock-up facilities for the development of an advanced spent fuel management process using molten salt technology

    International Nuclear Information System (INIS)

    Young-Joon Shin; Ik-Soo Kim; Seung-Chul Oh; Soo-Haeng Cho; Yo-Taik Song; Hyun-Soo Park

    2000-01-01

    The Korea Atomic Energy Research Institute (KAERI) has investigated a new approach to spent fuel storage technology that would reduce the total storage volume and the amount of decay heat. The technology utilizes the reduction of oxide fuel to a metal to reduce the volume and preferentially removing the fission products to reduce the decay heat. The uranium oxide is reduced to uranium metal by Li metal in a molten LiCl salt bath. During the reduction process, fission products are dissolved into the LiCl bath and some of the highly radioactive elements, such as Sr and Cs, are preferentially removed from the bath. The reduced uranium metal is cast into an ingot, put into a storage capsule, and stored using conventional storage methods. The fission products are treated as high level radioactive wastes. Each process of the technology has been studied and analyzed for technical feasibility, and has come to the point for designing and constructing of the mock-up for a demonstration of the technology. This paper presents the detailed design of the mock-up of the system and operational characteristics, along with all the details of the equipment for the system. KAERI plans to use the mock-up for the demonstration using an in-active spent fuel specimen. (authors)

  9. A new magnet for the LHC mock-up

    CERN Multimedia

    HSE Unit

    2013-01-01

    This year, the safety training centre on the Prévessin site acquired a mock-up of the LHC, which simulates the work and safety conditions in the tunnel.   Photo: Christoph Balle. A new dummy quadrupole has just been added to the magnet chain, making the mock-up even more realistic. The new facility, which was a joint endeavour by the TE, GS, BE and EN Departments, will significantly improve the quality of the various training courses held at the centre, particularly the course on the use of self-rescue masks. To consult the safety training catalogue and/or sign up for radiation protection training, please go to: https://cta.cern.ch. For further information, please contact the Safety Training and Awareness service by telephone on 73811 or 79935 or by e-mail to safety-training@cern.ch.  

  10. Beryllium mock-ups development and ultrasonic testing for ITER divertor conditions

    International Nuclear Information System (INIS)

    Barabash, V.R.; Bykov, V.A.; Giniyatulin, R.N.; Gervash, A.A.; Gurieva, T.M.; Egorov, K.E.; Komarov, V.L.; Korolkov, M.D.; Mazul, I.V.; Gitarsky, L.S.; Strulia, I.L.; Sizenev, V.S.; Pronyakin, V.T.

    1995-01-01

    At the present time beryllium is considered as the most suitable armour material for the ITER divertor application. Different types of Be-divertor mock-up construction are compared in the report. Two different technologies of beryllium tiles joining to a heat sink body are analysed: high temperature brazing and thermodiffusion bonding. The comparative analysis of different constructions has been performed on the basis of 2-D finite element calculation for temperatures and stresses. The main parameters and diagnostic capabilities of electron beam facility for HHF testing of beryllium mock-ups are described. The first results of HHF tests of ''beryllium-copper saddle-MAGT tube'' and ''beryllium-copper plate-SS body'' mock-ups are presented. The reasons of the damages during the HHF are analysed. The technique of ultrasonic testing of the thermodifussion bonding and brazing quality for beryllium-copper joints is presented. The recorded results are prepared in the form of ultrasound grams. The testing results are compared with the metallographic analysis. (orig.)

  11. The Effect of Mock Tests on Iranian EFL learners’ Test Scores

    OpenAIRE

    Hossein Khodabakhshzadeh; Reza Zardkanloo

    2016-01-01

    The effect of using tests in test preparation courses has been subject to debate. While some scholars such as Yang and Badger (2015) believe it is a cause of positive washback effect, others argue that this issue is tentative and context-bound (Green, 2007). Therefore, this study investigated the effect of using Mock tests in International English Language Testing System (IELTS) preparation courses on students’ overall IELTS scores. Fifty one IELTS students were selected non-randomly through ...

  12. Circulatory Markings at Double-Lane Traffic Roundabout.

    NARCIS (Netherlands)

    Bie, Jing; Lo, Hong K.; Wong, S.C.

    2008-01-01

    This paper compares two types of circulatory markings at a double-lane traffic roundabout: the concentric marking scheme and the Alberta marking scheme. The effects of these two marking schemes on drivers' lane choice behavior, delay, and safety, are compared based on data collected from before and

  13. A Mock Randomized Controlled Trial With Audience Response Technology for Teaching and Learning Epidemiology.

    Science.gov (United States)

    Baker, Philip R A; Francis, Daniel P; Cathcart, Abby

    2017-04-01

    The study's objective was to apply and assess an active learning approach to epidemiology and critical appraisal. Active learning comprised a mock, randomized controlled trial (RCT) conducted with learners in 3 countries. The mock trial consisted of blindly eating red Smarties candy (intervention) compared to yellow Smarties (control) to determine whether red Smarties increase happiness. Audience response devices were employed with the 3-fold purposes to produce outcome data for analysis of the effects of red Smarties, identify baseline and subsequent changes in participant's knowledge and confidence in understanding of RCTs, and assess the teaching approach. Of those attending, 82% (117 of 143 learners) participated in the trial component. Participating in the mock trial was a positive experience, and the use of the technology aided learning. The trial produced data that learners analyzed in "real time" during the class. The mock RCT is a fun and engaging approach to teaching RCTs and helping students to develop skills in critical appraisal.

  14. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death—Summary Report*

    Science.gov (United States)

    Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, ; Sonny; Sivarajan, V. Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A.; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D.

    2017-01-01

    Objectives: Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. Methods: We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. Results: We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation

  15. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death-Summary Report.

    Science.gov (United States)

    Weiss, Matthew J; Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, Sonny; Sivarajan, V Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D

    2017-11-01

    Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation after circulatory

  16. Tests on a mock-up of the feedback controlled matching options of the ITER ICRH system

    International Nuclear Information System (INIS)

    Grine, D.; Vervier, M.; Messiaen, A.; Dumortier, P.

    2009-01-01

    Automatic control of the matching of the ITER ICRH antenna array on a reference load is presently developed and tested for optimization on a low-powered scaled (1:5) mock-up. Resilience to fast load variations is obtained either by 4 Conjugate-T (CT) or 4 quadrature hybrid circuits, the latter being the reference option. The main results are (i) for the CT option: successful implementation of the simultaneous feedback control of 11 actuators for the matching of the 4 CT and for the control of the array toroidal phasing; (ii) for the hybrid option: the matching and the array current control via feedback control of the decouplers and double stub tuners. This system is being progressively implemented and the simultaneous control of matching and antenna current has already been successfully tested on half of the array for heating and current drive phasings.

  17. On the irrationality of Ramanujan's mock theta functions and other q-series at an infinite number of points

    OpenAIRE

    Mingarelli, Angelo B.

    2007-01-01

    We show that all of Ramanujan's mock theta functions of order 3, Watson's three additional mock theta functions of order 3, the Rogers-Ramanujan q-series, and 6 mock theta functions of order 5 take on irrational values at the points q=\\pm 1/2,\\pm 1/3,\\pm 1/4,...

  18. High heat load tests on W/Cu mock-ups and evaluation of their application to EAST device

    Energy Technology Data Exchange (ETDEWEB)

    Li, H. [Institute of Plasma Physics, Chinese Academy of Science, Hefei, Anhui 230031 (China); Hefei Electronic Engineering Institute, Hefei, Anhui 230037 (China)], E-mail: lih72@hotmail.com; Chen, J.L.; Li, J.G. [Institute of Plasma Physics, Chinese Academy of Science, Hefei, Anhui 230031 (China); Sun, X.J. [Hefei Electronic Engineering Institute, Hefei, Anhui 230037 (China)

    2009-01-15

    Tungsten has been considered as the primary candidate plasma-facing materials (PFM) for the EAST device. Three actively cooled W/Cu mock-ups with an interlayer made of tungsten-copper alloy (1.5 mm) were designed and manufactured. The tungsten armors, pure sintered tungsten plate (1 mm) and plasma-sprayed tungsten coatings (0.3 and 0.9 mm), were bonded to the interlayer by brazing and depositing respectively. All mock-ups can withstand high heat flux up to 5 MW/m{sup 2} and no obvious failure was found after tests. The thermal performance experiments and microstructure analyses indicated the structure of mock-ups possess good thermal contact and high heat transfer capability. WCu alloy as an interlayer can largely reduce the stress due to the mismatch and improve the reliability. The mock-up with 0.9 mm coating had the highest surface temperature than the other two mock-ups, delaminations of this mock-up were found in the near surface by SEM. The primary results show that pure sintered tungsten brazed to WCu alloy is a possible way, and thick plasma-sprayed coating technique still need to be improved.

  19. Ramanujan’s mock theta functions

    Science.gov (United States)

    Griffin, Michael; Ono, Ken; Rolen, Larry

    2013-01-01

    In his famous deathbed letter, Ramanujan introduced the notion of a mock theta function, and he offered some alleged examples. Recent work by Zwegers [Zwegers S (2001) Contemp Math 291:268–277 and Zwegers S (2002) PhD thesis (Univ of Utrecht, Utrecht, The Netherlands)] has elucidated the theory encompassing these examples. They are holomorphic parts of special harmonic weak Maass forms. Despite this understanding, little attention has been given to Ramanujan’s original definition. Here, we prove that Ramanujan’s examples do indeed satisfy his original definition. PMID:23536292

  20. Combinatorial identities for tenth order mock theta functions

    Indian Academy of Sciences (India)

    44

    which lead us to one 4-way and one 3-way combinatorial identity. ... mock theta functions, partition identities and different combinatorial parameters, see for ... 3. Example 1.1. There are twelve (n + 1)–color partitions of 2: 21, 21 + 01, 11 + 11, ...

  1. Application of a user-friendly comprehensive circulatory model for estimation of hemodynamic and ventricular variables

    NARCIS (Netherlands)

    Ferrari, G.; Kozarski, M.; Gu, Y. J.; De Lazzari, C.; Di Molfetta, A.; Palko, K. J.; Zielinski, K.; Gorczynska, K.; Darowski, M.; Rakhorst, G.

    2008-01-01

    Purpose: Application of a comprehensive, user-friendly, digital computer circulatory model to estimate hemodynamic and ventricular variables. Methods: The closed-loop lumped parameter circulatory model represents the circulation at the level of large vessels. A variable elastance model reproduces

  2. Annual report on experimental operations and maintenances of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system in 2003 fiscal year (Contract research)

    International Nuclear Information System (INIS)

    Hayashi, Koji; Morisaki, Norihiro; Ohashi, Hirofumi; Kato, Michio; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Inaba, Yoshitomo; Takada, Shoji; Inagaki, Yoshiyuki

    2006-03-01

    This is a report on the experimental operations and maintenances of the mock-up test facility with a full-scale reaction tube for the HTTR hydrogen production system in 2003 fiscal year. The fourth and fifth experimental test operations were performed, from May to July and from October to December in 2003, for the following tests; (a) start-up and shutdown operation test, (b) process change test, (c) continuous hydrogen-production test and (d) chemical reaction shutdown test. From the results, a long time-range stability of the hydrogen production system was confirmed, a behavior of the helium-gas cooling system, consists of steam generator and radiator; during chemical reaction shutdown, was understood, and so on. Periodic inspections on boiler equipment and high-pressure gas production facilities were performed from end of July 2003. This report is summarized on outlines and results of the tests, outlines and results of the periodic inspections, and operation records of the mock-up test facility. (author)

  3. Intraoperative care for aortic surgery using circulatory arrest.

    Science.gov (United States)

    Fernández Suárez, Félix Ezequiel; Fernández Del Valle, David; González Alvarez, Adrián; Pérez-Lozano, Blanca

    2017-05-01

    The total circulatory arrest (CA) is necessary to achieve optimal surgical conditions in certain aortic pathologies, especially in those affecting the ascending aorta and aortic arch. During this procedure it is necessary to protect all the organs of ischemia, especially those of the central nervous system and for this purpose several strategies have been developed. The first and most important protective method is systemic hypothermia. The degree of hypothermia and the route of application have been evolving and currently tend to use moderate hypothermia (MH) (20.1-28 °C) associated with unilateral or bilateral selective cerebral perfusion methods. In this way the neurological results are better, the interval of security is greater and the times of extracorporeal circulation are smaller. Even so, it is necessary to take into account that there is the possibility of ischemia in the lower part of the body, especially of the abdominal viscera and the spinal cord, therefore the time of circulatory stop should be limited and not to exceed 80 minutes. Evidence of possible neurological drug protection is very weak and only mannitol, magnesium, and statins can produce some benefit. Inhalational anesthetics and some intravenous seem to have advantages, but more studies would be needed to test their long-term benefit. Other important parameters to be monitored during these procedures are blood glucose, anemia and coagulation disorders and acid-base balance. The recommended monitoring is common in complex cardiovascular procedures and it is of special importance the neurological monitoring that can be performed with several techniques, although currently the most used are Bispectral Index (BIS) and Near-Infrared Spectroscopy (NIRS). It is also essential to monitor the temperature routinely at the nasopharyngeal and bladder level and it is important to control coagulation with rotational thromboelastometry (ROTEM).

  4. Fabrication of small mock-ups for the KO HCCR TBM

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jae Sung; Kim, Suk Kwon; Lee, Eo Hwak; Jin, Hyung Gon; Lee, Dong Won [KAERI, Daejeon (Korea, Republic of); Cho, Seung Yon [NFRI, Daejeon (Korea, Republic of)

    2016-05-15

    A fabrication procedure for the manufacturing of the HCCR TBM sub-module was performed and small mock-ups were fabricated using an E-beam and laser beam weld to verify the manufacturing procedure and method of the HCCR TBM sub-module. To establish and optimize the welding procedure in an E-beam weld from ARAA material, the distortion and radiographic tests were carried out from the E-beam weld results. It could be noted that a small amount of distortion occurred, but the values are small enough to neglect for the fabrication. In addition, a helium leak test and water pressure test will be performed for verification of the fabricated small mock-ups.

  5. High speed phototimer and biplane II blanking method in 105 mm RSC photographing of circulatory system

    International Nuclear Information System (INIS)

    Kaga, Yuji; Kiuchi, Shigeo; Sato, Masami; Komatsuda, Yasushi; Nishio, Kosaku.

    1979-01-01

    A high speed phototimer as an autoexposure mechanism was developed for 105 mm II indirect continuous photographing of circulatory system. The phototimer can give repeated response of 12 times/sec and the shortest X-ray shut out of 1 m sec. The proper lighting field for the phototimer is 7 mm diameter (12%) of the II input area, equivalent to 80 mm in diameter), and the tube voltage, object property and the focus-II distance characteristics are all well corrected to give good photographs of optimal density. The mutual fog in biplane photographing can be removed by adopting II blanking method. As blanking can respond quite rapidly, photographing time plus 2 m sec is enough for blanking time. That means the positive phase can be brought close to 3 m sec. This mechanism can be applied for biplane cine-photographing. (Kobatake, H.)

  6. Analysis of Dose Response for Circulatory Disease After Radiotherapy for Benign Disease

    Energy Technology Data Exchange (ETDEWEB)

    Little, Mark P., E-mail: mark.little@nih.gov [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States); Kleinerman, Ruth A. [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States); Stovall, Marilyn; Smith, Susan A. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Mabuchi, Kiyohiko [Radiation Epidemiology Branch, National Cancer Institute, Executive Plaza South, Rockville, Maryland (United States)

    2012-12-01

    Purpose: To assess the shape of the dose-response for various circulatory disease endpoints, and modifiers by age and time since exposure. Methods and Materials: This was an analysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by circulatory disease endpoint (ischemic heart, cerebrovascular, other circulatory disease). Results: There were significant excess risks for all circulatory disease, with an excess relative risk Gy{sup -1} of 0.082 (95% CI 0.031-0.140), and ischemic heart disease, with an excess relative risk Gy{sup -1} of 0.102 (95% CI 0.039-0.174) (both p = 0.01), and indications of excess risk for stroke. There were no statistically significant (p > 0.2) differences between risks by endpoint, and few indications of curvature in the dose-response. There were significant (p < 0.001) modifications of relative risk by time since exposure, the magnitude of which did not vary between endpoints (p > 0.2). Risk modifications were similar if analysis was restricted to patients receiving radiation, although the relative risks were slightly larger and the risk of stroke failed to be significant. The slopes of the dose-response were generally consistent with those observed in the Japanese atomic bomb survivors and in occupationally and medically exposed groups. Conclusions: There were excess risks for a variety of circulatory diseases in this dataset, with significant modification of risk by time since exposure. The consistency of the dose-response slopes with those observed in radiotherapeutically treated groups at much higher dose, as well as in lower dose-exposed cohorts such as the Japanese atomic bomb survivors and nuclear workers, implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.

  7. Mock Quasar-Lyman-α forest data-sets for the SDSS-III Baryon Oscillation Spectroscopic Survey

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Julian E.; Busca, Nicolas G. [APC, Université Paris Diderot-Paris 7, CNRS/IN2P3, CEA, Observatoire de Paris, 10, rue A. Domon and L. Duquet, Paris (France); Bailey, Stephen; Font-Ribera, Andreu; Schlegel, David [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA (United States); Pieri, Matthew M. [Aix Marseille Université, CNRS, LAM (Laboratoire d' Astrophysique de Marseille) UMR 7326, 38 rue Frédéric Joliot-Curie, 13388, Marseille (France); Miralda-Escudé, Jordi; Gontcho, Satya Gontcho A. [Institut de Ciències del Cosmos, Universitat de Barcelona/IEEC, 1 Martí i Franquès, Barcelona 08028, Catalonia (Spain); Palanque-Delabrouille, Nathalie; Rich, James; Goff, Jean Marc Le [CEA, Centre de Saclay, Irfu/SPP, D128, F-91191 Gif-sur-Yvette (France); Dawson, Kyle [Department of Physics and Astronomy, University of Utah, 115 S 100 E, RM 201, Salt Lake City, UT 84112 (United States); Feng, Yu; Ho, Shirley [McWilliams Center for Cosmology, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213 (United States); Ge, Jian [Department of Astronomy, University of Florida, 211 Bryant Space Science Center, Gainesville, FL 32611-2055 (United States); Noterdaeme, Pasquier; Pâris, Isabelle [Université Paris 6 et CNRS, Institut d' Astrophysique de Paris, 98bis blvd. Arago, 75014 Paris (France); Rossi, Graziano, E-mail: bautista@astro.utah.edu [Department of Astronomy and Space Science, Sejong University, 209 Neungdong-ro, Gwangjin-gu, Seoul, 143-747 (Korea, Republic of)

    2015-05-01

    We describe mock data-sets generated to simulate the high-redshift quasar sample in Data Release 11 (DR11) of the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). The mock spectra contain Lyα forest correlations useful for studying the 3D correlation function including Baryon Acoustic Oscillations (BAO). They also include astrophysical effects such as quasar continuum diversity and high-density absorbers, instrumental effects such as noise and spectral resolution, as well as imperfections introduced by the SDSS pipeline treatment of the raw data. The Lyα forest BAO analysis of the BOSS collaboration, described in Delubac et al. 2014, has used these mock data-sets to develop and cross-check analysis procedures prior to performing the BAO analysis on real data, and for continued systematic cross checks. Tests presented here show that the simulations reproduce sufficiently well important characteristics of real spectra. These mock data-sets will be made available together with the data at the time of the Data Release 11.

  8. Current Status of Mechanical Circulatory Support: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Kyriakos Spiliopoulos

    2012-01-01

    Full Text Available Heart failure is a major public health problem and its management requires a significant amount of health care resources. Even with administration of the best available medical treatment, the mortality associated with the disease remains high. As therapeutical strategies for heart failure have been refined, the number of patients suffering from the disease has expanded dramatically. Although heart transplantation still represents the gold standard therapeutical approach, the implantation of mechanical circulatory support devices (MCSDs evolved to a well-established management for this disease. The limited applicability of heart transplantation caused by a shortage of donor organs and the concurrent expand of the patient population with end-stage heart failure led to a considerable utilization of MCSDs. This paper outlines the current status of mechanical circulatory support.

  9. Best Practices in Preparing Students for Mock Interviews

    Science.gov (United States)

    Hansen, Katharine; Oliphant, Gary C.; Oliphant, Becky J.; Hansen, Randall S.

    2009-01-01

    Studies have shown the importance of employment interview preparation in boosting the confidence and performance of students and jobseekers when they interview. This article reviews several techniques for preparing students for mock job interviews and, hence, actual job interviews. For instructors who would like to enhance the learning value of…

  10. Demonstration of the LHC Safety Training Tunnel Mock-Up

    CERN Multimedia

    Brice, Maximilien

    2014-01-01

    Members of CERN's management visit the LHC tunnel mock-up at the Safety Training Centre on the Prévessin site. The facility is used to train personnel in emergency responses including the use of masks and safe evacuation.

  11. Status report on active stabilisation of a linear collider final focus quadrupole mock-up

    International Nuclear Information System (INIS)

    Lottin, J.; Brunetti, L.; Formosa, F.; Adloff, C.; Bastian, Y.; Bolzon, B.; Cadoux, F.; Geffroy, N.; Girard, C.; Jeremie, A.; Karyotakis, Y.; Peltier, F.

    2006-01-01

    The measurements done with the sensors available in our laboratories used for ground motion analysis are presented. The first sensors studied are seismic sensors measuring ground velocity, other sensors are accelerometers available for measuring ground acceleration. The first step has been to characterize the sensors, the second step has been to model and simulate the acceleration in order to identify Eigen frequencies and to display mode shapes. The third step has been to assess the performances of a new algorithm for disturbance rejection. In order to facilitate the analysis, a reduced-size mock-up has been used. The goal was to eliminate or at least to reduce as much as possible the main frequencies of the disturbance. A new mock-up is currently being developed that will have a geometry closer to a final focus quadrupole. Measurements will be done to validate the whole system in view of active stabilization for a future linear collider

  12. Status report on active stabilisation of a linear collider final focus quadrupole mock-up

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, J.; Brunetti, L.; Formosa, F. [Universite de Savoie, ESIA, 74 - Annecy (France); Adloff, C.; Bastian, Y.; Bolzon, B.; Cadoux, F.; Geffroy, N.; Girard, C.; Jeremie, A.; Karyotakis, Y.; Peltier, F. [LAPP-IN2P3-CNRS, 74 - Annecy-le-Vieux (France)

    2006-07-01

    The measurements done with the sensors available in our laboratories used for ground motion analysis are presented. The first sensors studied are seismic sensors measuring ground velocity, other sensors are accelerometers available for measuring ground acceleration. The first step has been to characterize the sensors, the second step has been to model and simulate the acceleration in order to identify Eigen frequencies and to display mode shapes. The third step has been to assess the performances of a new algorithm for disturbance rejection. In order to facilitate the analysis, a reduced-size mock-up has been used. The goal was to eliminate or at least to reduce as much as possible the main frequencies of the disturbance. A new mock-up is currently being developed that will have a geometry closer to a final focus quadrupole. Measurements will be done to validate the whole system in view of active stabilization for a future linear collider.

  13. Implementation and evaluation of a simulation curriculum for paediatric residency programs including just-in-time in situ mock codes.

    Science.gov (United States)

    Sam, Jonathan; Pierse, Michael; Al-Qahtani, Abdullah; Cheng, Adam

    2012-02-01

    To develop, implement and evaluate a simulation-based acute care curriculum in a paediatric residency program using an integrated and longitudinal approach. Curriculum framework consisting of three modular, year-specific courses and longitudinal just-in-time, in situ mock codes. Paediatric residency program at BC Children's Hospital, Vancouver, British Columbia. The three year-specific courses focused on the critical first 5 min, complex medical management and crisis resource management, respectively. The just-in-time in situ mock codes simulated the acute deterioration of an existing ward patient, prepared the actual multidisciplinary code team, and primed the surrounding crisis support systems. Each curriculum component was evaluated with surveys using a five-point Likert scale. A total of 40 resident surveys were completed after each of the modular courses, and an additional 28 surveys were completed for the overall simulation curriculum. The highest Likert scores were for hands-on skill stations, immersive simulation environment and crisis resource management teaching. Survey results also suggested that just-in-time mock codes were realistic, reinforced learning, and prepared ward teams for patient deterioration. A simulation-based acute care curriculum was successfully integrated into a paediatric residency program. It provides a model for integrating simulation-based learning into other training programs, as well as a model for any hospital that wishes to improve paediatric resuscitation outcomes using just-in-time in situ mock codes.

  14. Combinatorics of tenth-order mock theta functions

    Indian Academy of Sciences (India)

    θ(q) there is some root of unity ζ for which f (q) − θ(q) is unbounded as q → ζ rapidly. In the long list of 17 mock theta functions given by Ramanujan, few have been interpreted combinatorially. For example, (q) defined by (1.1) below, has been interpreted by Fine. [8] as a generating function for partitions into odd parts without ...

  15. External validation of prediction models for time to death in potential donors after circulatory death

    NARCIS (Netherlands)

    Kotsopoulos, A.M.M.; Böing-Messing, F.; Jansen, N.E.; Vos, P.; Abdo, W.F.

    2018-01-01

    Predicting time to death in controlled donation after circulatory death (cDCD) donors following withdrawal of life‐sustaining treatment (WLST) is important but poses a major challenge. The aim of this study is to determine factors predicting time to circulatory death within 60 minutes after WSLT and

  16. Enhancement of arterial pressure pulsatility by controlling continuous-flow left ventricular assist device flow rate in mock circulatory system

    NARCIS (Netherlands)

    Bozkurt, S.; van de Vosse, F.N.; Rutten, M.C.M.

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase

  17. Improvement works report on mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system (Contract research)

    International Nuclear Information System (INIS)

    Sakaki, Akihiro; Kato, Michio; Hayashi, Koji; Fujisaki, Katsuo; Aita, Hideki; Ohashi, Hirofumi; Takada, Shoji; Shimizu, Akira; Morisaki, Norihiro; Maeda, Yukimasa; Sato, Hiroyuki; Hanawa, Hiromi; Yonekawa, Hideo; Inagaki, Yoshiyuki

    2005-04-01

    In order to establish the system integration technology to connect a hydrogen production system to a high temperature gas cooled reactor; the mock-up test facility with a full-scale reaction tube for the steam reforming HTTR hydrogen production system was constructed in fiscal year 2001 and its functional test operation was performed in the year. Seven experimental test operations were performed from fiscal year 2001 to 2004. On a period of each test operation, there happened some troubles. For each trouble, the cause was investigated and the countermeasures and the improvement works were performed to succeed the experiments. The tests were successfully achieved according to plan. This report describes the improvement works on the test facility performed from fiscal year 2001 to 2004. (author)

  18. Experimental Investigation of the IFMIF Target Mock-up

    International Nuclear Information System (INIS)

    Loginov, N.; Mikheyev, A.; Morozov, V.; Aksenov, Y.; Arnoldov, M.; Berensky, L.; Fedotovsky, V.; Chernov, V.M.; Nakamura, H.

    2007-01-01

    Full text of publication follows: The IFMIF lithium neutron target mock-ups have been constructed and tested at the water and lithium test facilities. Description of the mock-ups and test facilities is presented in the paper, as well as the main results obtained. Reference geometry was used but the mockup flow cross-section was decreased. Velocity of water and lithium was up to reference value of 20 m/s. Features of lithium and water hydrodynamics were observed. The calculations and experiments showed that conjunction point of back wall straight and concave sections generated instability of lithium flow because of centrifugal force sudden change at this place. Therefore, it was proposed to use parabolic shape of the target back wall. Generation of wakes at the corners of cross-section of the Shima nozzle outlet was observed, and, as a result, surface waves appeared on the lithium jet. Observations of lithium and water jets and measurements of water jet thickness showed significant increasing the thickness near sidewalls of the mock-up concave section. It is because of absence of the centrifugal force at these places. Very large instability of the water jet surface was observed when outlet part of the Shima nozzle was divergent slightly (about 1 deg.), and vice versa very smooth jet surface occurred in confusing case (of about 0.5 deg.). So, nozzle outlet shape is very critical. Evaporation of lithium from the jet surface was investigated as well as deposition of vapor on vacuum pipe wall. It turned out to be not so critical. Significant part of the work concerned purification of lithium and monitoring impurities. The possibility of denitration of lithium down to 2 ppm by means of aluminum soluble getter was showed. Two types of both cold traps and plug indicators of impurities were tested. The results are presented in the paper. (authors)

  19. Mock-up critical experiments for prototype fast breeder reactor 'Monju'

    International Nuclear Information System (INIS)

    Zukeran, Atsushi; Inoue, Teruji; Suzuki, Takeo; Kawashima, Kanau

    1976-01-01

    The mock-up criticality experiments for Monju are roughly divided into the full mock-up test using the ZEBRA of Winfrith Institute, UK AEA, and the partial mock-up experiment with FCA of JAERI. The former test has been carried out over 18 months from September 1971 as the Japan-UK cooperative research project MOZART. With the FCA, the experiment complementing the MOZART has been carried out, focusing on the nuclear characteristics of Monju which can be simulated with a relatively small core, and the experiment on highly enriched control rods and shielding is being continued now with the FCA 7 core. The experimental data of the MOZART and the ZPPR series in USA were exchanged at the international symposium in Tokyo, thus the prediction and the accuracy evaluation of the nuclear characteristics of Monju became possible, and the highly reliable core design was able to be accomplished. The simulated criticality experiment is necessary for directly grasping the reliability of calculated values in comparison with the experimental values, and also for the experimental prediction of the nuclear characteristics. The outline and the analysis of the simulated criticality experiment such as reactivity factor, control rod value, reaction rate distribution and sodium void reactivity are described, and the reflection of the results to the design of the core of Monju is explained. (Kako, I.)

  20. Sizable variations in circulatory disease mortality by region and country of birth in six European countries

    DEFF Research Database (Denmark)

    Rafnsson, Snorri B; Bhopal, Raj S; Agyemang, Charles

    2013-01-01

    BACKGROUND: Circulatory disease mortality inequalities by country of birth (COB) have been demonstrated for some EU countries but pan-European analyses are lacking. We examine inequalities in circulatory mortality by geographical region/COB for six EU countries. METHODS: We obtained national deat...

  1. Mock-up test of remote controlled dismantling apparatus for large-sized vessels (contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Myodo, Masato; Miyajima, Kazutoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Okane, Shogo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    2001-03-01

    The Remote dismantling apparatus, which is equipped with multi-units for functioning of washing, cutting, collection of cut pieces and so on, has been constructed to dismantle the large-sized vessels in the JAERI's Reprocessing Test Facility (JRTF). The apparatus has five-axis movement capability and its operation is performed remotely. The mock-up tests were performed to evaluate the applicability of the apparatus to actual dismantling activities by using the mock-ups of LV-3 and LV-5 in the facility. It was confirmed that each unit was satisfactory functioned by remote operation. Efficient procedures for dismantling the large-sized vessel was studied and various date was obtained in the mock-up tests. This apparatus was found to be applicable for the actual dismantling activity in JRTF. (author)

  2. Mock-up test of remote controlled dismantling apparatus for large-sized vessels (contract research)

    International Nuclear Information System (INIS)

    Myodo, Masato; Miyajima, Kazutoshi; Okane, Shogo

    2001-03-01

    The Remote dismantling apparatus, which is equipped with multi-units for functioning of washing, cutting, collection of cut pieces and so on, has been constructed to dismantle the large-sized vessels in the JAERI's Reprocessing Test Facility (JRTF). The apparatus has five-axis movement capability and its operation is performed remotely. The mock-up tests were performed to evaluate the applicability of the apparatus to actual dismantling activities by using the mock-ups of LV-3 and LV-5 in the facility. It was confirmed that each unit was satisfactory functioned by remote operation. Efficient procedures for dismantling the large-sized vessel was studied and various date was obtained in the mock-up tests. This apparatus was found to be applicable for the actual dismantling activity in JRTF. (author)

  3. Scandinavian SSAI clinical practice guideline on choice of first-line vasopressor for patients with acute circulatory failure

    DEFF Research Database (Denmark)

    Møller, M H; Claudius, C; Junttila, E

    2016-01-01

    BACKGROUND: Adult critically ill patients often suffer from acute circulatory failure, necessitating use of vasopressor therapy. The aim of the Scandinavian Society of Anaesthesiology and Intensive Care Medicine (SSAI) task force for Acute Circulatory Failure was to present clinically relevant...... to recommendations. We assessed the following subpopulations of patients with acute circulatory failure: 1) shock in general, 2) septic shock, 3) cardiogenic shock, 4) hypovolemic shock and 5) other types of shock, including vasodilatory shock. We assessed patient-important outcome measures, including mortality...

  4. Weld distortion prediction and control of the ITER vacuum vessel manufacturing mock-ups

    International Nuclear Information System (INIS)

    Ottolini, Marco; Barbensi, Andrea

    2014-01-01

    The fabrication of the ITER Vacuum Vessel Sectors is an unprecedented challenge, due to their dimensions, the close tolerances, the complex 'D' shape. The technological issues were faced by the production of full scale mock ups to confirm the manufacturing feasibility to achieve very tight tolerances and qualify the main manufacturing processes, by a step by step welding distortion control, by the qualification of not conventional NDT inspection techniques and by innovative 3D dimensional inspections. The Supplier is required to fabricate at least two mock ups, inboard and outboard, related to the manufacturing method of the VV Sectors, to demonstrate the control of the welding distortions to achieve tolerances, optimizing welding sequences and calibrating of welding distortions computer simulations. The stages of this preparatory activity are: prediction of welding distortion for fabrication mock ups representative of selected segments; demonstration that distortion predictions are consistent with experimental results from 3D dimensional inspection; understanding of reasons of possible deviations between numerical and experimental results and definition of action to solve these issues; demonstration that possible calculation simplifications, adopted to speed up the analysis process, do not affect significantly the welding distortion prediction. This paper describes the weld distortion prediction and control on the manufacturing mock-ups of ITER Vacuum Vessel Sectors, with particular emphasis to the lessons learned. (authors)

  5. In-Pile thermal fatigue of First Wall mock-ups under ITER relevant conditions

    International Nuclear Information System (INIS)

    Blom, F.; Schmalz, F.; Kamer, S.; Ketema, D.J.

    2006-01-01

    The objective of this study is to perform in-pile thermal fatigue testing of three actively cooled First Wall (FW) mock-ups to check the effect of neutron irradiation on the Be/CuCrZr joints under representative FW operation conditions. Three FW mock-ups with Beryllium armor tiles will be neutron irradiated at 1 dpa (in Be) with parallel thermal fatigue testing for 30,000 cycles. The temperatures, stress distributions and stress amplitudes at the Be/CuCrZr interface of the mock-ups will be as close as possible to the values calculated for ITER FW panels. For this objective the PWM mocks-up subjected to thermal fatigue will be integrated with high density (W) plates on the Be-side to provide heat flux by nuclear heating. The assembly will be placed in the pool-side facility of the HFR and thermal cycling is then arranged by mechanical movement towards and from the core box. As the thermal design of the irradiation rig is very critical a pilot-irradiation will be performed to cross check the models used in the thermal design of the rig. The project is currently in the design phase of both the pilot and actual irradiation rig. The irradiation of the actual rig is planned to start at mid 2007 and last for two years. (author)

  6. A cause of circulatory collapse that should be considered following trauma

    Directory of Open Access Journals (Sweden)

    Omar Hesham R

    2010-08-01

    Full Text Available Abstract Management of poly-trauma patients presenting to the emergency room is usually a challenging and formidable task. Two of the common problems seen in those patients are shock and neurological dysfunction. A huge differential for post-traumatic circulatory collapse exist and timely identification of the etiology is of utmost importance to avoid complications. In this report we are describing 2 cases presenting with circulatory collapse following trauma. The first case was a 29 year old female who presented after a motor vehicle accident fully conscious with severe hypotension and bradycardia. The second case presented with severe hemodynamic instability after falling at home. Physical examination of both patients revealed weakness in all 4 limbs and CT cervical spine revealed complete anterior sublaxation of C5 over C6 cervical vertebrae in the first case and partial sublaxation of C5 over C6 cervical vertebrae in the second case confirming that spinal cord injury is the likely cause for these hemodynamic alterations. A high index of suspicion for spinal cord injuries is therefore mandatory when managing a trauma patient presenting with quadriparesis and hemodynamic instability that is otherwise unexplained especially when the ensuing hypotension is associated with bradycardia instead of reflex tachycardia. Awareness of this cause of circulatory collapse is particularly important in the unconscious patient where eliciting sensory and motor deficits looking for spinal cord injury is not always feasible. Both patients were transferred to the intensive care unit and were maintained on epinephrine till becoming hemodynamically stable. The report aims to sensitize readers to this cause of post-traumatic circulatory collapse.

  7. Using an integrative mock-up simulation approach for evidence-based evaluation of operating room design prototypes.

    Science.gov (United States)

    Bayramzadeh, Sara; Joseph, Anjali; Allison, David; Shultz, Jonas; Abernathy, James

    2018-07-01

    This paper describes the process and tools developed as part of a multidisciplinary collaborative simulation-based approach for iterative design and evaluation of operating room (OR) prototypes. Full-scale physical mock-ups of healthcare spaces offer an opportunity to actively communicate with and to engage multidisciplinary stakeholders in the design process. While mock-ups are increasingly being used in healthcare facility design projects, they are rarely evaluated in a manner to support active user feedback and engagement. Researchers and architecture students worked closely with clinicians and architects to develop OR design prototypes and engaged clinical end-users in simulated scenarios. An evaluation toolkit was developed to compare design prototypes. The mock-up evaluation helped the team make key decisions about room size, location of OR table, intra-room zoning, and doors location. Structured simulation based mock-up evaluations conducted in the design process can help stakeholders visualize their future workspace and provide active feedback. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Mock-up experiment at Birmingham University for BNCT project of Osaka University – Neutron flux measurement with gold foil

    International Nuclear Information System (INIS)

    Tamaki, S.; Sakai, M.; Yoshihashi, S.; Manabe, M.; Zushi, N.; Murata, I.; Hoashi, E.; Kato, I.; Kuri, S.; Oshiro, S.; Nagasaki, M.; Horiike, H.

    2015-01-01

    Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error. - Highlights: • Accelerator based neutron source for BNCT is being developed in Osaka University. • Mock-up experiment was carried out at Birmingham University, UK. • Neutronics performance of our assembly was evaluated from gold foil activation. • Gold foil activation was determined by using HPGe detectors. • Validity of the neutronics design code system was confirmed.

  9. IMPROVED MOCK GALAXY CATALOGS FOR THE DEEP2 GALAXY REDSHIFT SURVEY FROM SUBHALO ABUNDANCE AND ENVIRONMENT MATCHING

    Energy Technology Data Exchange (ETDEWEB)

    Gerke, Brian F.; Wechsler, Risa H.; Behroozi, Peter S. [Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Accelerator Laboratory, M/S 29, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States); Cooper, Michael C. [Center for Galaxy Evolution, Department of Physics and Astronomy, University of California-Irvine, Irvine, CA 92697 (United States); Yan, Renbin [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States); Coil, Alison L., E-mail: bgerke@slac.stanford.edu [Center for Astrophysics and Space Sciences, University of California, San Diego, 9500 Gilman Dr., MC 0424, La Jolla, CA 92093 (United States)

    2013-09-15

    We develop empirical methods for modeling the galaxy population and populating cosmological N-body simulations with mock galaxies according to the observed properties of galaxies in survey data. We use these techniques to produce a new set of mock catalogs for the DEEP2 Galaxy Redshift Survey based on the output of the high-resolution Bolshoi simulation, as well as two other simulations with different cosmological parameters, all of which we release for public use. The mock-catalog creation technique uses subhalo abundance matching to assign galaxy luminosities to simulated dark-matter halos. It then adds color information to the resulting mock galaxies in a manner that depends on the local galaxy density, in order to reproduce the measured color-environment relation in the data. In the course of constructing the catalogs, we test various models for including scatter in the relation between halo mass and galaxy luminosity, within the abundance-matching framework. We find that there is no constant-scatter model that can simultaneously reproduce both the luminosity function and the autocorrelation function of DEEP2. This result has implications for galaxy-formation theory, and it restricts the range of contexts in which the mock catalogs can be usefully applied. Nevertheless, careful comparisons show that our new mock catalogs accurately reproduce a wide range of the other properties of the DEEP2 catalog, suggesting that they can be used to gain a detailed understanding of various selection effects in DEEP2.

  10. IMPROVED MOCK GALAXY CATALOGS FOR THE DEEP2 GALAXY REDSHIFT SURVEY FROM SUBHALO ABUNDANCE AND ENVIRONMENT MATCHING

    International Nuclear Information System (INIS)

    Gerke, Brian F.; Wechsler, Risa H.; Behroozi, Peter S.; Cooper, Michael C.; Yan, Renbin; Coil, Alison L.

    2013-01-01

    We develop empirical methods for modeling the galaxy population and populating cosmological N-body simulations with mock galaxies according to the observed properties of galaxies in survey data. We use these techniques to produce a new set of mock catalogs for the DEEP2 Galaxy Redshift Survey based on the output of the high-resolution Bolshoi simulation, as well as two other simulations with different cosmological parameters, all of which we release for public use. The mock-catalog creation technique uses subhalo abundance matching to assign galaxy luminosities to simulated dark-matter halos. It then adds color information to the resulting mock galaxies in a manner that depends on the local galaxy density, in order to reproduce the measured color-environment relation in the data. In the course of constructing the catalogs, we test various models for including scatter in the relation between halo mass and galaxy luminosity, within the abundance-matching framework. We find that there is no constant-scatter model that can simultaneously reproduce both the luminosity function and the autocorrelation function of DEEP2. This result has implications for galaxy-formation theory, and it restricts the range of contexts in which the mock catalogs can be usefully applied. Nevertheless, careful comparisons show that our new mock catalogs accurately reproduce a wide range of the other properties of the DEEP2 catalog, suggesting that they can be used to gain a detailed understanding of various selection effects in DEEP2

  11. Early Identification of Circulatory Shock in Critical Care Transport

    Science.gov (United States)

    2008-09-30

    disclosure and community consultation. Early Identification of Circulatory Shock in Critical Care Transport 2 Community consultation for this...in two aircraft types (Eurocopter EC 135 and EC 145), in IFR weather conditions, and during both day and night operations. We calculated the

  12. Mock Target Window OTR and IR Design and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-19

    In order to fully verify temperature measurements made on the target window using infrared (IR) optical non-contact methods, actual comparative measurements are made with a real beam distribution as the heat source using Argonne National Laboratory’s (ANL) 35 MeV electron accelerator. Using Monte Carlo N-Particle (MCNP) simulations and thermal Finite Element Analysis (FEA), a cooled mock target window with thermocouple implants is designed to be used in such a test to achieve window temperatures up to 700°C. An uncoated and blackcoated mock window is designed to enhance the IR temperature measurements and verify optical transmitted radiation (OTR) imagery. This allows us to fully verify and characterize our temperature accuracy with our current IR camera method and any future method we may wish to explore using actual production conditions. This test also provides us with valuable conclusions/concerns regarding the calibration method we developed using our IR test stand at TA-53 in MPF-14.

  13. Running tests in isolation using mock objects

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    "Mocking" is a technique used in unit-testing that replace external dependencies with "fake" objects, simulating the behavior of the real ones. This process is usually applied when the existence of these dependencies makes impossible to write proper tests or when its result can be non-deterministic, hard to reproduce and/or slow to calculate. In this talk, I will briefly describe this technique and show how and where to use it through some examples.

  14. Enhancement of the use of digital mock-ups in the verification and validation process for ITER remote handling systems

    Energy Technology Data Exchange (ETDEWEB)

    Sibois, R., E-mail: romain.sibois@vtt.fi [VTT Technical Research Centre of Finland, P.O. Box 1300, 33101 Tampere (Finland); Salminen, K.; Siuko, M. [VTT Technical Research Centre of Finland, P.O. Box 1300, 33101 Tampere (Finland); Mattila, J. [Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); Määttä, T. [VTT Technical Research Centre of Finland, P.O. Box 1300, 33101 Tampere (Finland)

    2013-10-15

    Highlights: • Verification and validation process for ITER remote handling system. • Verification and validation framework for complex engineering systems. • Verification and validation roadmap for digital modelling phase. • Importance of the product life-cycle management in the verification and validation framework. -- Abstract: The paper is part of the EFDA's programme of European Goal Oriented Training programme on remote handling (RH) “GOT-RH”. The programme aims to train engineers for activities supporting the ITER project and the long-term fusion programme. This paper is written based on the results of a project “verification and validation (V and V) of ITER RH system using digital mock-ups (DMUs)”. The purpose of this project is to study efficient approach of using DMU for the V and V of the ITER RH system design utilizing a system engineering (SE) framework. This paper reviews the definitions of DMU and virtual prototype and overviews the current trends of using virtual prototyping in the industry during the early design phase. Based on the survey of best industrial practices, this paper proposes ways to improve the V and V process for ITER RH system utilizing DMUs.

  15. FBR core mock-up RAPSODIE I - experimental analysis

    International Nuclear Information System (INIS)

    Brochard, D.; Buland, P.; Gantenbein, F.

    1990-01-01

    The main phenomena which influence the LMFBR core response to a seismic excitation are the fluid structure interaction and the impacts between subassemblies. To study the core behaviour, seismic tests have been performed on the core mock-up RAPSODIE with and without fluid and restraint ring and for different levels of excitation. This paper summarizes the results of these tests. (author)

  16. Destructive analysis on the ITER FW small scale mock-ups

    International Nuclear Information System (INIS)

    Wang, Pinghuai; Chen, Jiming; Liu, Danhua; Jin, Fanya; Yang, Bo

    2015-01-01

    As one of the core components of ITER, the first wall (FW) panel of shield blanket defines a physical boundary for the plasma transients and exhausts the majority of the plasma heat flux. China will undertake 12.64% of FW manufacturing tasks, and all of them are enhanced heat flux (EHF) components which will suffer surface heat flux of 4 - 5 MW/m 2 . The FW will be manufactured by a combination technology of explosion bonding CuCrZr alloy/316L (N) stainless steel plate and hot iso-static pressing (HIP) joining of beryllium tiles/CuCrZr alloy. The Be/Cu joint qualities is the key issue for the manufacturing of the FW panels. Several small scale mock-ups were manufactured for the qualification of the HIP technology for the FW. To avoid the brittle Be-Cu phase formed during the HIPing process, different thick Ti and pure Cu were coated on the beryllium tiles before HIPing to CuCrZr alloy. Ultrasonic testing was conducted on the mock-ups and destructive analysis was carried out on the mock-ups. For the failed ones, the results show that in the UT indication area brittle fracture occurs at the Be/Ti interface and then Ti/Cu interface in other areas. Based on these results, the manufacturing technology was improved mainly on the beryllium tiles quality, coating process and canister design. (author)

  17. ITER baffle module small-scale mock-ups: first wall thermo-mechanical testing results

    International Nuclear Information System (INIS)

    Severi, Y.; Giancarli, L.; Poitevin, Y.; Salavy, J.F.; Le Marois, G.; Roedig, M.; Vieider, G.

    1998-01-01

    The EU-home team is in charge of the R and D related to the ITER baffle first wall. Five small-scale mock-ups, using Be, CFC and W tiles and different armour/heat-sink material joints under development, have been fabricated and thermomechanically tested in FE200 (Le Creusot) and JUDITH (Juelich) electron beam facilities. The small-scale mock-ups have been submitted to thermo-mechanical fatigue tests (up to failure using accelerating techniques). The objective was to determine the performances of the armour material joints under high heat flux cycles. (orig.)

  18. Analysis of the impacts of the J-TEXT TBM mock-up on the equilibrium magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhengqing [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, and College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Rao, Bo, E-mail: borao@hust.edu.cn [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, and College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Zhang, Ming; Zhang, Jun [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, and College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Wang, Weihua [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); New Star Institute of Applied Technology, Hefei 230031 (China); Liu, Sumei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); School of Engineering,Anhui Agricultural University, Hefei 230036 (China)

    2016-11-01

    Highlights: • J-TEXT TBM mock-up was designed and fabricated to test and study the distribution of eddy current, electromagnetic and thermal load on the TBM during plasma disruption. • This paper focuses on evaluating the influence of the TBM structural material (RAMF steel) to tokamak discharge and security. The simulation data presents a relatively complete assessment of impacts of the J-TEXT TBM mock-up on the equilibrium magnetic field. • The conclusion of the simulation will offer the guidance for installation interface design of the TBM mock-up. - Abstract: The Test Blanket Module (TBM) will be used in the test port of ITER to demonstrate tritium self-sufficiency and the extraction of high grade heat for electricity production. J-TEXT TBM mock-up using reduced activation ferritic/martensitic (RAFM) steel as structural material was designed and fabricated to perform and validate relevant electromagnetic and thermal technologies of the China Helium-Cooled Ceramic Breeder Test Blanket Module (CN HCCB-TBM) on the J-TEXT. Its size is one third of the CN HCCB-TBM. By using the finite element analysis technology, this paper analyzed the impacts on the equilibrium magnetic field over the plasma region after introducing the structure material RAFM steel. The distribution of toroidal field (TF) ripple and the magnitude of the error field with the mock-up at different positions were given. Simulation shows the distribution of the null field region formed by poloidal field (PF). The influence to tokamak discharge has been evaluated by drawing the magnetic field lines. Based on the results above, we have optimized and finished the installation of the mock-up to J-TEXT which meets the needs of the experiments and to ensure the normal discharge.

  19. A generalized approach for historical mock-up acquisition and data modelling: Towards historically enriched 3D city models

    Science.gov (United States)

    Hervy, B.; Billen, R.; Laroche, F.; Carré, C.; Servières, M.; Van Ruymbeke, M.; Tourre, V.; Delfosse, V.; Kerouanton, J.-L.

    2012-10-01

    Museums are filled with hidden secrets. One of those secrets lies behind historical mock-ups whose signification goes far behind a simple representation of a city. We face the challenge of designing, storing and showing knowledge related to these mock-ups in order to explain their historical value. Over the last few years, several mock-up digitalisation projects have been realised. Two of them, Nantes 1900 and Virtual Leodium, propose innovative approaches that present a lot of similarities. This paper presents a framework to go one step further by analysing their data modelling processes and extracting what could be a generalized approach to build a numerical mock-up and the knowledge database associated. Geometry modelling and knowledge modelling influence each other and are conducted in a parallel process. Our generalized approach describes a global overview of what can be a data modelling process. Our next goal is obviously to apply this global approach on other historical mock-up, but we also think about applying it to other 3D objects that need to embed semantic data, and approaching historically enriched 3D city models.

  20. New Innovations in Circulatory Support With Ventricular Assist Device and Extracorporeal Membrane Oxygenation Therapy.

    Science.gov (United States)

    Sladen, Robert N

    2017-04-01

    The past decade has seen an exponential increase in the application and development of durable long-term as well as nondurable short-term mechanical circulatory support for cardiogenic shock and acute or chronic heart failure. Support has evolved from bridge-to-transplant to destination therapy, bridge to rescue, bridge to decision making, and bridge to a bridge. Notable trends include device miniaturization, minimally invasive and/or percutaneous insertion, and efforts to superimpose pulsatility on continuous flow. We can certainly anticipate that innovation will accelerate in the months and years to come. However, despite-or perhaps because of-the enhanced equipment now available, mechanical circulatory support is an expensive, complex, resource-intensive modality. It requires considerable expertise that should preferably be centralized to highly specialized centers. Formidable challenges remain: systemic inflammatory response syndromes and vasoplegia after device insertion; postoperative sepsis; optimal anticoagulation regimens to prevent device-induced thrombosis and cerebral thromboembolism; wound site, intracranial, and gastrointestinal bleeding; multisystem injury and failure; patient dissatisfaction (even when providers consider the procedure a "success"); and ethical decision making in conditions of futility.

  1. Thermal fatigue tests with actively cooled divertor mock-ups for ITER

    International Nuclear Information System (INIS)

    Roedig, M.; Duwe, R.; Linke, J.; Schuster, A.; Wiechers, B.; Ibbott, C.; Jacobson, D.; Le Marois, G.; Lind, A.; Lorenzetto, P.; Vieider, G.; Peacock, A.; Ploechl, L.; Severi, Y.; Visca, E.

    1998-01-01

    Mock-ups for high heat flux components with beryllium and CFC armour materials have been tested by means of the electron beam facility JUDITH. The experiments concerned screening tests to evaluate heat removal efficiency and thermal fatigue tests. CFC monoblocks attached to DS-Cu (Glidcop Al25) and CuCrZr tubes by active metal casting and Ti brazing showed the best thermal fatigue behaviour. They survived more than 1000 cycles at heat loads up to 25 MW m -2 without any indication of failure. Operational limits are given only by the surface temperature on the CFC tiles. Most of the beryllium mock-ups were of the flat tile type. Joining techniques were brazing, hot isostatic pressing (HIP) and diffusion bonding. HIPed and diffusion bonded Be/Cu modules have not yet reached the standards for application in high heat flux components. The limit of this production method is reached for heat loads of approximately 5 MW m -2 . Brazing with and without silver seems to be a more robust solution. A flat tile mock-up with CuMnSnCe braze was loaded at 5.4 MW m -2 for 1000 cycles without damage The first test with a beryllium monoblock joined to a CuCrZr tube by means of Incusil brazing shows promising results; it survived 1000 cycles at 4.5 MW m -2 without failure. (orig.)

  2. Dark Energy Survey Year 1 Results: galaxy mock catalogues for BAO

    Energy Technology Data Exchange (ETDEWEB)

    Avila, S.; et al.

    2017-12-17

    Mock catalogues are a crucial tool in the analysis of galaxy surveys data, both for the accurate computation of covariance matrices, and for the optimisation of analysis methodology and validation of data sets. In this paper, we present a set of 1800 galaxy mock catalogues designed to match the Dark Energy Survey Year-1 BAO sample (Crocce et al. 2017) in abundance, observational volume, redshift distribution and uncertainty, and redshift dependent clustering. The simulated samples were built upon HALOGEN (Avila et al. 2015) halo catalogues, based on a $2LPT$ density field with an exponential bias. For each of them, a lightcone is constructed by the superposition of snapshots in the redshift range $0.45mock catalogues and compare their clustering to the data using the angular correlation function $ w(\\theta)$, the comoving transverse separation clustering $\\xi_{\\mu<0.8}(s_{\\perp})$ and the angular power spectrum $C_\\ell$.

  3. Novel circulatory connection from the acupoint Zhong Wan(CV12 to pancreas

    Directory of Open Access Journals (Sweden)

    Minsoo Kim

    2008-03-01

    Full Text Available Objectives : Demonstrating a novel circulatory path from the acupoint(CV12 to the pancreas. Method : Alcian blue(1% solution, 20μl, pH 7.4 was injected into the acupoint(CV12. Two hours later the surfaces of internal organs were observed by using a stereomicroscope. Results : Alcian blue arrived and colored the omental fat band(OFB on the pancreas. The OFB connected the head and tail of the pancreas, the pancreas and the spleen, and the pancreas and the stomach. Conclusion : The existence of a novel circulatory path from the acupoint CV12 to the pancreas and its OFB was demonstrated.

  4. Mock Pages Are a Valid Construct for Assessment of Clinical Decision Making and Interprofessional Communication.

    Science.gov (United States)

    Boehler, Margaret L; Schwind, Cathy J; Markwell, Stephen J; Minter, Rebecca M

    2017-01-01

    Answering pages from nurses about patients in need of immediate attention is one of the most difficult challenges a resident faces during their first days as a physician. A Mock Page program has been developed and adopted into a national surgical resident preparatory curriculum to prepare senior medical students for this important skill. The purpose of this study is to assess standardized mock page cases as a valid construct to assess clinical decision making and interprofessional communication skills. Mock page cases (n = 16) were administered to 213 senior medical students from 12 medical schools participating in a national surgical resident preparatory curriculum in 2013 and 2014. Clinical decision making and interprofessional communication were measured by case-specific assessments evaluating these skills which have undergone rigorous standard-setting to determine pass/fail cut points. Students' performance improved in general for both communication and clinical decision making over the 4-week course. Cases have been identified that seem to be best suited for differentiating high- from low-performing students. Chest pain, pulmonary embolus, and mental status change cases posed the greatest difficulty for student learners. Simulated mock pages demonstrate an innovative technique for training students in both effective interprofessional communication and management of common postoperative conditions they will encounter as new surgical interns.

  5. High heat flux testing of ITER ICH&CD antenna beryllium faraday screen bars mock-ups

    International Nuclear Information System (INIS)

    Courtois, X.; Meunier, L.; Kuznetsov, V.; Beaumont, B.; Lamalle, P.; Conchon, D.; Languille, P.

    2016-01-01

    Highlights: • ITER ICH&CD antenna beryllium faraday screen bars mock-ups were manufactured. • The mock-ups are submitted to high heat loads to test their heat exhaust capabilities. • The mock-ups withstand without damage the design limit load. • Lifetime is gradually reduced when the heat load is augmented beyond the design limit. • Thermal and mechanical behavior are reproducible, and coherent with the calculation. - Abstract: The Faraday Screen (FS) is the plasma facing component of ITER ion cyclotron heating antennas shielding. The requirement for the high heat exhaust, and the limitation of the temperatures to minimize strain and thus offer sufficient resistance to fatigue, imply the need for high conductivity materials and a high cooling flow rate. The FS bars are constructed by a hipping process involving beryllium tiles, a pure copper layer, a copper chrome zirconium alloy for the cooling channel and a stainless steel backing strip. Two FS bars small scale mock-ups were manufactured and tested under high heat flux. They endured 15,000 heating cycles without degradation under nominal heat flux, and revealed growing flaws when the heat flux was progressively augmented beyond. In this case, the ultrasonic test confirms a strong delamination of the Be tiles.

  6. Design and validation of the THMC China-Mock-Up test on buffer material for HLW disposal

    Directory of Open Access Journals (Sweden)

    Yuemiao Liu

    2014-04-01

    Full Text Available According to the preliminary concept of the high-level radioactive waste (HLW repository in China, a large-scale mock-up facility, named China-Mock-Up was constructed in the laboratory of Beijing Research Institute of Uranium Geology (BRIUG. A heater, which simulates a container of radioactive waste, is placed inside the compacted Gaomiaozi (GMZ-Na-bentonite blocks and pellets. Water inflow through the barrier from its outer surface is used to simulate the intake of groundwater. The numbers of water injection pipes, injection pressure and the insulation layer were determined based on the numerical modeling simulations. The current experimental data of the facility are herein analyzed. The experiment is intended to evaluate the thermo-hydro-mechano-chemical (THMC processes occurring in the compacted bentonite-buffer during the early stage of HLW disposal and to provide a reliable database for numerical modeling and further investigation of engineered barrier system (EBS, and the design of HLW repository.

  7. Tests and measurements with a thermal VXD mock-up for BELLE II

    International Nuclear Information System (INIS)

    Huebner, Lars

    2015-03-01

    As part of the Belle detector upgrade, located at the KEK in Tsukuba, Japan, a CO 2 cooling system will be added. Using new detector components, which are easily damageable or influenced by heat, make this step necessary. Particularly the next to the beam pipe located PXD is strained by high thermal load and therefore requires cooling. The CDC needs a constant temperature for precise measurements, but it could be influenced by heat from the SVD. Knowledge about the heat generation and distribution is needed before assembling the full detector. A mock-up of the innermost parts of the detector and a CO 2 cooling system is under construction at DESY in Hamburg, Germany, to gather such knowledge. The mock-up should be able to emulate the thermal properties of the final detector. Within the scope of this bachelor's thesis, the outermost VXD Layer 6 was studied in a flat arrangement. Focus lay on the heat dissipation at the sensors and on pressure drop measurements of the cooling pipe. It was investigated whether the applied heat load can be sufficiently lead away and how large the pressure drop is along the experiment line. Despite cooling was applied, a remarkable rise in temperature was observed. However, the unfavorable position of the thermistors make reliable quantitative statements of the sensor dummies' temperatures impossible. The pressure drop was determined, but is of limited accuracy due to large uncertainties. Further investigations have to be made with a better set-up.

  8. F.B.R. Core mock-up RAPSODIE - II - numerical models

    International Nuclear Information System (INIS)

    Brochard, D.; Hammami, L.; Gantenbein, F.

    1990-01-01

    To study the behaviour of LMFBR cores excited by a seism, tests have been performed on the RAPSODIE core mock-up. The aim of this paper is to present the numerical models used to interprete these tests and the comparisons between calculations and experimental results

  9. Sequential Participation in a Multi-Institutional Mock Oral Examination Is Associated With Improved American Board of Surgery Certifying Examination First-Time Pass Rate.

    Science.gov (United States)

    Fingeret, Abbey L; Arnell, Tracey; McNelis, John; Statter, Mindy; Dresner, Lisa; Widmann, Warren

    We sought to determine whether sequential participation in a multi-institutional mock oral examination affected the likelihood of passing the American Board of Surgery Certifying Examination (ABSCE) in first attempt. Residents from 3 academic medical centers were able to participate in a regional mock oral examination in the fall and spring of their fourth and fifth postgraduate year from 2011 to 2014. Candidate׳s highest composite score of all mock orals attempts was classified as risk for failure, intermediate, or likely to pass. Factors including United States Medical Licensing Examination steps 1, 2, and 3, number of cases logged, American Board of Surgery In-Training Examination performance, American Board of Surgery Qualifying Examination (ABSQE) performance, number of attempts, and performance in the mock orals were assessed to determine factors predictive of passing the ABSCE. A total of 128 mock oral examinations were administered to 88 (71%) of 124 eligible residents. The overall first-time pass rate for the ABSCE was 82%. There was no difference in pass rates between participants and nonparticipants. Of them, 16 (18%) residents were classified as at risk, 47 (53%) as intermediate, and 25 (29%) as likely to pass. ABSCE pass rate for each group was as follows: 36% for at risk, 84% for intermediate, and 96% for likely pass. The following 4 factors were associated with first-time passing of ABSCE on bivariate analysis: mock orals participation in postgraduate year 4 (p = 0.05), sequential participation in mock orals (p = 0.03), ABSQE performance (p = 0.01), and best performance on mock orals (p = 0.001). In multivariable logistic regression, the following 3 factors remained associated with ABSCE passing: ABSQE performance, odds ratio (OR) = 2.9 (95% CI: 1.3-6.1); mock orals best performance, OR = 1.7 (1.2-2.4); and participation in multiple mock oral examinations, OR = 1.4 (1.1-2.7). Performance on a multi-institutional mock oral examination can identify

  10. Use of Short-term Circulatory Support as a Bridge in Pediatric Heart Transplantation

    Directory of Open Access Journals (Sweden)

    Luiz Fernando Canêo

    2015-01-01

    Full Text Available Background: Heart transplantation is considered the gold standard therapy for the advanced heart failure, but donor shortage, especially in pediatric patients, is the main limitation for this procedure, so most sick patients die while waiting for the procedure. Objective: To evaluate the use of short-term circulatory support as a bridge to transplantation in end-stage cardiomyopathy. Methods: Retrospective clinical study. Between January 2011 and December 2013, 40 patients with cardiomyopathy were admitted in our Pediatric Intensive Care Unit, with a mean age of 4.5 years. Twenty patients evolved during hospitalization with clinical deterioration and were classified as Intermacs 1 and 2. One patient died within 24 hours and 19 could be stabilized and were listed. They were divided into 2 groups: A, clinical support alone and B, implantation of short-term circulatory support as bridge to transplantation additionally to clinical therapy. Results: We used short-term mechanical circulatory support as a bridge to transplantation in 9. In group A (n=10, eight died waiting and 2 patients (20% were transplanted, but none was discharged. In group B (n=9, 6 patients (66.7% were transplanted and three were discharged.The mean support time was 21,8 days (6 to 984h. The mean transplant waiting list time was 33,8 days. Renal failure and sepsis were the main complication and causeof death in group A while neurologic complications were more prevalent en group B. Conclusion: Mechanical circulatory support increases survival on the pediatric heart transplantation waiting list in patients classified as Intermacs 1 and 2.

  11. Plasma FITC-dextran exchange between the primary and secondary circulatory systems in the Atlantic cod, Gadus Morhua

    DEFF Research Database (Denmark)

    Fischer, Claes; Steffensen, John Fleng

    2008-01-01

    Fluorescein isothiocyanate dextran (FITC-dextran) exchange between the primary (PCS) and secondary (SCS) circulatory systems in the Atlantic cod, Gadus morhua (Linnaeus, 1752), were studied using 20-kDa (n = 4) and 500-kDa (n = 4) FITC-dextran. In order to give a qualitative perspective...... of the general connection between the PCS and SCS, distribution of plasma-borne tracers (FITC-dextran) in the PCS and SCS were examined. In this study, a total of eight cod were cannulated in the ventral aorta (PCS) and dorsal cutaneous vessel (SCS), for investigation of FITC-dextran disappearance in the PCS...... and its subsequent appearance in the SCS. FITC-dextran of both sizes was found to be in equilibrium between the PCS and SCS in less than 20 min. This indicates a profound connection between the PCS and SCS in the Atlantic cod, and rapid mixing of tracers between the PCS and SCS. The destination...

  12. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  13. The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    DEFF Research Database (Denmark)

    de By, Theo M M H; Mohacsi, Paul; Gummert, Jan

    2015-01-01

    other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry...

  14. Machine learning etudes in astrophysics: selection functions for mock cluster catalogs

    Energy Technology Data Exchange (ETDEWEB)

    Hajian, Amir; Alvarez, Marcelo A.; Bond, J. Richard, E-mail: ahajian@cita.utoronto.ca, E-mail: malvarez@cita.utoronto.ca, E-mail: bond@cita.utoronto.ca [Canadian Institute for Theoretical Astrophysics, University of Toronto, Toronto, ON M5S 3H8 (Canada)

    2015-01-01

    Making mock simulated catalogs is an important component of astrophysical data analysis. Selection criteria for observed astronomical objects are often too complicated to be derived from first principles. However the existence of an observed group of objects is a well-suited problem for machine learning classification. In this paper we use one-class classifiers to learn the properties of an observed catalog of clusters of galaxies from ROSAT and to pick clusters from mock simulations that resemble the observed ROSAT catalog. We show how this method can be used to study the cross-correlations of thermal Sunya'ev-Zeldovich signals with number density maps of X-ray selected cluster catalogs. The method reduces the bias due to hand-tuning the selection function and is readily scalable to large catalogs with a high-dimensional space of astrophysical features.

  15. Machine learning etudes in astrophysics: selection functions for mock cluster catalogs

    International Nuclear Information System (INIS)

    Hajian, Amir; Alvarez, Marcelo A.; Bond, J. Richard

    2015-01-01

    Making mock simulated catalogs is an important component of astrophysical data analysis. Selection criteria for observed astronomical objects are often too complicated to be derived from first principles. However the existence of an observed group of objects is a well-suited problem for machine learning classification. In this paper we use one-class classifiers to learn the properties of an observed catalog of clusters of galaxies from ROSAT and to pick clusters from mock simulations that resemble the observed ROSAT catalog. We show how this method can be used to study the cross-correlations of thermal Sunya'ev-Zeldovich signals with number density maps of X-ray selected cluster catalogs. The method reduces the bias due to hand-tuning the selection function and is readily scalable to large catalogs with a high-dimensional space of astrophysical features

  16. Re-analysis of HCPB/HCLL Blanket Mock-up Experiments Using Recent Nuclear Data Libraries

    International Nuclear Information System (INIS)

    Kondo, K.; Fischer, U.; Klix, A.; Pereslavtsev, P.; Serikov, A.; Villari, R.

    2014-01-01

    We have re-analysed the two breeding blankets experiments performed previously in the frame of the European fusion program on two mock-ups of the European Helium-Cooled-Lithiium Lead (HCLL) and Helium-Cooled-Pebble-Bed (HCPB) test blanket modules for ITER. The tritium production rate and the neutron and photon spectra measured in these mock-ups were compared with calculations using FENDL-3 Starter Library, release 4 and state-of-the-art nuclear data evaluations, JEFF-3.1.2, JENDL-4.0 and ENDF/B-VII.0. The tritium production calculated for the HCPB mock-up underestimates the experimental result by about 10%. The result calculated with FENDL-3/SLIB4 gives slightly smaller tritium production by 2% than the one with FENDL-2.1. The difference attributes to the slight modification of the total and elastic scattering cross section of Be. For the HCLL experiment, all libraries reproduce the experimental results well. FENDL-3/SLIB4 gives better result both for the measured spectra and the tritium production compared to FENDL-2.1

  17. Reconstructing the distribution of haloes and mock galaxies below the resolution limit in cosmological simulations

    OpenAIRE

    de la Torre, Sylvain; Peacock, John A.

    2012-01-01

    We present a method for populating dark matter simulations with haloes of mass below the resolution limit. It is based on stochastically sampling a field derived from the density field of the halo catalogue, using constraints from the conditional halo mass function n(m|{\\delta}). We test the accuracy of the method and show its application in the context of building mock galaxy samples. We find that this technique allows precise reproduction of the two-point statistics of galaxies in mock samp...

  18. Getting home with artifical heart – what is the everyday life experience of people with mechanical circulatory Support. A qualitative study

    Science.gov (United States)

    Braunsdorf, Sandy

    2017-07-01

    Background: The growing number of mechanical circulatory support systems implanted with successful results in terms of quality of life and physical resilience means that more and more people are being discharged from hospital to live at home with an artificial heart. This puts high requirements on affected persons’ disease and therapy management – a subject which has attracted very little qualitative research to date. Aim: This study therefore sought to shed light on how people with mechanical circulatory support experience their everyday lives. The aim was to document the subjective associations of those affected from an insider perspective. Methods: Following the interpretative phenomenological paradigm, narrative interviews were conducted with two female and eight male participants. For qualitative analysis, a multi-step process guided by the methodology of hermeneutic philosophy was used. Results: The qualitative data analysis revealed five main topic areas. These describe patients’ state of health after implantation and the various adjustments, constraints and pressures necessitated by their illness and therapeutic requirements. On this basis, coping and management strategies are identified. Other significant aspects of patients’ everyday lives are social interaction and environment and health care with an artificial heart. Conclusions: The findings add to our knowledge of the day-to-day lives of people with mechanical circulatory support systems, giving us a better understanding of their specific situation.

  19. The supply of small scale mock-ups of the primary wall module concepts for ITER

    International Nuclear Information System (INIS)

    Walsh, G.; Cheyne, K.; Lorenzetto, P.

    1998-01-01

    The present design of Blanket Shield and Primary Wall for ITER envisages construction of the wall with a water cooled, stainless steel outer layer and a water cooled, copper liner on the inside plasma facing surface. Protection of the inner copper surface with an armour layer is necessary to cope with plasma to wall interaction. There are a number of armour materials under consideration, for this project beryllium was used. The scope of work was to produce a series of mock-ups, each consisting of a different combination of materials, which included Dispersion Strengthened Copper, Copper-Chrome-Zirconium alloy, Beryllium and Stainless Steel. Hot Isostatic Pressing (HIP) was the method used to ensure that a fully diffused bonded joint was achieved giving the necessary strength and thermal conductivity. The first five of the mock ups have been successfully completed and are being tested at the various laboratories in Europe. The remaining mock ups are awaiting the results of this test work prior to being completed. (authors)

  20. Mock-up test results of monoblock-type CFC divertor armor for JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Higashijima, S. [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)], E-mail: higashijima.satoru@jaea.go.jp; Sakurai, S.; Suzuki, S.; Yokoyama, K.; Kashiwa, Y.; Masaki, K.; Shibama, Y.K.; Takechi, M.; Shibanuma, K.; Sakasai, A.; Matsukawa, M.; Kikuchi, M. [Japan Atomic Energy Agency, 801-1 Mukoyama, Naka, Ibaraki 311-0193 (Japan)

    2009-06-15

    The JT-60 Super Advanced (JT-60SA) tokamak project starts under both the Japanese domestic program and the international program 'Broader Approach'. The maximum heat flux to JT-60SA divertor is estimated to {approx}15 MW/m{sup 2} for 100 s. Japan Atomic Energy Agency (JAEA) has developed a divertor armor facing high heat flux in the engineering R and D for ITER, and it is concluded that monoblock-type CFC divertor armor is promising for JT-60SA. The JT-60SA armor consists of CFC monoblocks, a cooling CuCrZr screw-tube, and a thin oxygen-free high conductivity copper (OFHC-Cu) buffer layer between the CFC monoblock and the screw-tube. CFC/OFHC-Cu and OFHC-Cu/CuCrZr joints are essential for the armor, and these interfaces are brazed. Needed improvements from ITER engineering R and D are good CFC/OFHC-Cu and OFHC-Cu/CuCrZr interfaces and suppression of CFC cracking. For these purposes, metalization inside CFC monoblock is applied, and we confirmed again that the mock-up has heat removal capability in excess of ITER requirement. For optimization of the fabrication method and understanding of the production yield, the mock-ups corresponding to quantity produced in one furnace at the same time is also produced, and the half of the mock-ups could remove 15 MW/m{sup 2} as required. This paper summarizes the recent progress of design and mock-up test results for JT-60SA divertor armor.

  1. The Trial of Napoleon: A Case Study for Using Mock Trials.

    Science.gov (United States)

    MacKay, Charles

    2000-01-01

    Describes a course entitled "The Trial of Napoleon Bonaparte" that focuses on a fictitious mock trial of Napoleon Bonaparte to answer the question: did Napoleon pervert or preserve the gain of the French Revolution? Discusses the strengths and weaknesses of the course. (CMK)

  2. Mock Trial: A Window to Free Speech Rights and Abilities

    Science.gov (United States)

    Schwartz, Sherry

    2010-01-01

    This article provides some strategies to alleviate the current tensions between personal responsibility and freedom of speech rights in the public school classroom. The article advocates the necessity of making sure students understand the points and implications of the first amendment by providing a mock trial unit concerning free speech rights.…

  3. Numerical studies on helium cooled divertor finger mock up with sectorial extended surfaces

    International Nuclear Information System (INIS)

    Rimza, Sandeep; Satpathy, Kamalakanta; Khirwadkar, Samir; Velusamy, Karupanna

    2014-01-01

    Highlights: • Studies on heat transfer enhancement for divertor finger mock-up. • Heat transfer characteristics of jet impingement with extended surfaces have been investigated. • Effect of critical parameters that influence the thermal performance of the finger mock-up by CFD approach. • Effect of extended surface in enhancing heat removal potential with pumping power assessed. • Practicability of the chosen design is verified by structural analysis. - Abstract: Jet impinging technique is an advance divertor concept for the design of future fusion power plants. This technique is extensively used due to its high heat removal capability with reasonable pumping power and for safe operation. In this design, plasma-facing components are fabricated with numerous fingers cooled by helium jets to reduce the thermal stresses. The present study is focused towards finding an optimum performance of one such finger mock-up through systematic computational fluid dynamics (CFD) studies. Heat transfer characteristics of jet impingement have been numerically investigated with sectorial extended surfaces (SES). The result shows that addition of SES enhances heat removal potential with minimum pumping power. Detailed parametric studies on critical parameters that influence thermal performance of the finger mock-up have been analyzed. Thermo-mechanical analysis has been carried out through finite element based approach to know the state of stress in the assembly as a result of large temperature gradients. It is seen that the stresses are within the permissible limits for the present design. The whole numerical simulation has been carried out using general-purpose CFD software (ANSYS FLUENT, Release 14.0, User Guide, Ansys, Inc., 2011). Benchmark validation studies have been performed against high-heat flux experiments (B. Končar, P. Norajitra, K. Oblak, Appl. Therm. Eng., 30, 697–705, 2010) and a good agreement is noticed between the present simulation and the reported

  4. Validation of CLIC Re-Adjustment System Based on Eccentric Cam Movers One Degree of Freedom Mock-Up

    CERN Document Server

    Kemppinen, J; Lackner, F

    2011-01-01

    Compact Linear Collider (CLIC) is a 48 km long linear accelerator currently studied at CERN. It is a high luminosity electron-positron collider with an energy range of 0.5-3 TeV. CLIC is based on a two-beam technology in which a high current drive beam transfers RF power to the main beam accelerating structures. The main beam is steered with quadrupole magnets. To reach CLIC target luminosity, the main beam quadrupoles have to be actively pre-aligned within 17 µm in 5 degrees of freedom and actively stabilised at 1 nm in vertical above 1 Hz. To reach the pre-alignment requirement as well as the rigidity required by nano-stabilisation, a system based on eccentric cam movers is proposed for the re-adjustment of the main beam quadrupoles. Validation of the technique to the stringent CLIC requirements was started with tests in one degree of freedom on an eccentric cam mover. This paper describes the dedicated mock-up as well as the tests and measurements carried out with it. Finally, the test results are present...

  5. Optoacoustic measurement of central venous oxygenation for assessment of circulatory shock: clinical study in cardiac surgery patients

    Science.gov (United States)

    Petrov, Irene Y.; Prough, Donald S.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. Nan; Seeton, Roger; Salter, Michael G.; Esenaliev, Rinat O.

    2014-03-01

    Circulatory shock is a dangerous medical condition, in which blood flow cannot provide the necessary amount of oxygen to organs and tissues. Currently, its diagnosis and therapy decisions are based on hemodynamic parameters (heart rate, blood pressure, blood gases) and mental status of a patient, which all have low specificity. Measurement of mixed or central venous blood oxygenation via catheters is more reliable, but highly invasive and associated with complications. Our previous studies in healthy volunteers demonstrated that optoacoustic systems provide non-invasive measurement of blood oxygenation in specific vessels, including central veins. Here we report our first results of a clinical study in coronary artery bypass graft (CABG) surgery patients. We used a medical-grade OPO-based optoacoustic system developed in our laboratory to measure in real time blood oxygenation in the internal jugular vein (IJV) of these patients. A clinical ultrasound imaging system (GE Vivid e) was used for IJV localization. Catheters were placed in the IJV as part of routine care and blood samples taken via the catheters were processed with a CO-oximeter. The optoacoustic oxygenation data were compared to the CO-oximeter readings. Good correlation between the noninvasive and invasive measurements was obtained. The results of these studies suggest that the optoacoustic system can provide accurate, noninvasive measurements of central venous oxygenation that can be used for patients with circulatory shock.

  6. Development of the ITER IOIS assembly tool and mock-up

    International Nuclear Information System (INIS)

    Nam, Kyoungo; Kim, Dongjin; Park, Hyunki; Ahn, Heejae; Kim, Kyoungkyu; Yoo, Yongsoo; Watson, Emma; Shaw, Robert

    2014-01-01

    The ITER toroidal field coils (TFCs) are connected by 3 different connecting structures as follows; Outer Intercoil Structure (OIS), Inner Intercoil Structure (IIS), Intermediate Outer Intercoil Structure (IOIS). In assessing the assembly, requirements and environmental conditions of each Intercoil structure, the IOIS and IIS assembly were thought to be the most challenging compared to the OIS assembly due to the very limited assembly space available and the strict requirements requested by IO, especially the IOIS assembly, which has particularly difficult installation requirements including complicated shear pin assemblies. A conceptual and preliminary design has been developed by the Korean domestic agency (KODA) for the sub assembly and final assembly phase; the tool includes the ability to control both IOIS plates simultaneously. For design verification of the IOIS assembly tool mentioned above, structural analysis has been carried out considering seismic event. Also, a half sized mock-up has been fabricated and tested according to assembly procedures. In this paper, a description of tool design and the results of analysis and mock-test will be introduced

  7. A proposal of ITER vacuum vessel fabrication specification and results of the full-scale partial mock-up test

    Energy Technology Data Exchange (ETDEWEB)

    Nakahira, Masataka; Takeda, Nobukazu; Onozuka, Masanori [Japan Atomic Energy Agency (Japan); Kakudate, Satoshi [Mitsubishi Heavy Industries, Ltd. (Japan)

    2007-07-01

    The structure and fabrication methods of the ITER vacuum vessel have been investigated and defined by the ITER international team. However, some of the current specifications are very difficult to be achieved from the manufacturing point of view and will lead to cost increase. In the mock-up fabrication, it is planned to conduct the following items: 1. Feasibility of the Japanese proposed VV structure and fabrication methods and the applicability to the ITER are to be confirmed; 2. Assembly procedure and inspection procedure are to be confirmed; 3. Manufacturing tolerances are to be assessed; 4. Manufacturing schedule is to be assessed. This report summarizes the Japanese proposed specification of the VV mock-up describing differences between the ITER supplied design. General scope of the mock-up fabrication and the detailed dimensions are also shown. In the VV fabrication, several types of weld joint configuration will be used. This report shows the joint configurations proposed by Japan to be used for the inner shell connection, the rib-to-shell connection and outer shell connection, and the housing-to-shell connection, respectively. Non-destructive testing considered to be applied to each joint configuration is also presented. A series of the fabrication and assembly procedures for the mock-up are presented in this report, together with candidates of welding configurations. Finally, the report summarizes the results of mock-up fabrication, including results of nondestructive examination of weld lines, obtained welding deformation and issues revealed from the fabrication experience. (orig.)

  8. Manufacturing and testing of a copper/CFC divertor mock-up for JET

    International Nuclear Information System (INIS)

    Brossa, M.; Ciric, D.; Deksnis, E.; Falter, H.; Guerreschi, U.; Peacock, A.; Pick, M.; Rossi, M.; Shen, Y.; Zacchia, F.

    1995-01-01

    An actively cooled divertor is a possible option for future developments at The Joint European Torus (JET). A proof of principle actively cooled tile has been produced in order to qualify the relevant manufacturing technologies and the non destructive control processes. In this frame Ansaldo Ricerche (ARI) has been involved in the construction of a mock-up comprising 6 OFHC copper tubes for water cooling that are brazed to a plate made out of carbon fibre composite (CFC). The final objective was the high heat flux testing of the mock-up at JET in order to evaluate the general behaviour of the component under relevant operating conditions. The key point of the work was the realisation of a sound joint by adapting the expertise gained in ARI in previous R and D activities on brazing heterogeneous materials. Reliable methods for ultrasonic examinations of the pieces were also set up. For successful application to the JET pumped divertor a water-cooled CFC target plate must show surface temperatures of 2 . Furthermore, global hydraulic considerations specific to JET limit the system pressure to 0.7 MPa. In such a design, critical heat flux is not the key limit, rather the reliability of the CFC-copper joint in terms of extent of wetting. First tests in the neutral beam test bed at JET show an adequate response for fluxes up to 15 MW/m 2 . (orig.)

  9. Implementation of a Digital Mock-up for Remote Hot cell Operations

    International Nuclear Information System (INIS)

    Park, Hee Seong; Park, Byung Suk; Kim, Sung Hyun; Kim, Ki Ho; Kim, Ho Dong

    2010-01-01

    A remote manipulation environment that a human operator has to observe is the inner side of a hotcell through a lead grass window which has many obstacles due to many existing 'blind-spots' where are several cameras installed. The lack of visual information when operating in a cluttered environment makes manoeuvering a manipulator very difficult and when this situation is exacerbated by strict time limits for a task completion, then a manipulator and environmental collisions and resultant damage can occur. To cope with these problems, there has been efforts to develop a virtual simulator to validate control programs visually and to establish maintainability-engineering tools that automate generation assembly/disassembly procedures by using Computer Aided Design(CAD) visualization systems with human figure models to virtual reality systems where engineers can interact with the system using virtual input devices. This article introduces a system that can simulate a deployment analysis on a digital mock-up effectively and proposes a scheme to enable an operator to improve a remote manipulation by using a haptic device

  10. High heat flux tests of mock-ups for ITER divertor application

    International Nuclear Information System (INIS)

    Giniatulin, R.; Gervash, A.; Komarov, V.L.; Makhankov, A.; Mazul, I.; Litunovsky, N.; Yablokov, N.

    1998-01-01

    One of the most difficult tasks in fusion reactor development is the designing, fabrication and high heat flux testing of actively cooled plasma facing components (PFCs). At present, for the ITER divertor project it is necessary to design and test components by using mock-ups which reflect the real design and fabrication technology. The cause of failure of the PFCs is likely to be through thermo-cycling of the surface with heat loads in the range 1-15 MW m -2 . Beryllium, tungsten and graphite are considered as the most suitable armour materials for the ITER divertor application. This work presents the results of the tests carried out with divertor mock-ups clad with beryllium and tungsten armour materials. The tests were carried out in an electron beam facility. The results of high heat flux screening tests and thermo-cycling tests in the heat load range 1-9 MW m -2 are presented along with the results of metallographic analysis carried out after the tests. (orig.)

  11. Contribution of Circulatory Disturbances in Subchondral Bone to the Pathophysiology of Osteoarthritis.

    Science.gov (United States)

    Aaron, Roy K; Racine, Jennifer; Dyke, Jonathan P

    2017-08-01

    This review describes the contributions of abnormal bone circulation to the pathophysiology of osteoarthritis. Combining dynamic imaging with MRI and PET with previous observations reveals that venous stasis and a venous outlet syndrome is most likely the key circulatory pathology associated with the initiation or progression of osteoarthritis. MRI and PET have revealed that venous outflow obstruction results in physicochemical changes in subchondral bone to which osteoblasts are responsive. The osteoblasts express an altered pattern of cytokines, many of which can serve as structural or signaling molecules contributing to both bone remodeling and cartilage degeneration. The patterns of circulatory changes are associated with alterations in the physicochemical environment of subchondral bone, including hypoxia. Osteoblast cytokines can transit the subchondral bone plate and calcified cartilage and communicate with chondrocytes.

  12. The risk mortality of the population of azerbaijan from circulatory diseases, depending on the season

    Directory of Open Access Journals (Sweden)

    A. J. Rzayeva

    2015-06-01

    Azerbaijan State Advanced Training Institute for doctors named after A. Aliyev, Baku   ABSTRACT The Objective.  To obtain evidence-based data about the role of seasons of the year in the formation of the population mortality risk from the circulatory system diseases  (CSD in Azerbaijan and its regions with specific climate. Materials of the study. A case of mortality was a unit of statistical observation. The fatalities from all reasons, including CSD have been distributed by the days of every month in the year. Daily average amount of fatalities by months and seasons ( from 20 December to 19 March – winter; from 20 March to 19 June- spring; from 20 June to 16 September; from 20 September to 19 December - autumn have been determined. Results.  In Azerbaijan the risk of general mortality and mortality from CSD is the highest in winter, it decreases in spring but nonuniformly (the general mortality rate is less than that from CSD. That is why the share of CSD increases among mortality reasons. Conclusions. Seasonal change of mortality risks from CSD is multivariant. Winter-spring increase of risk predominates in Azerbaijan. In some regions of Azerbaijan the mortality risk from CSD increases only once either in spring or in summer or winter. Key words: seasonal dynamics, risk of mortality, circulatory system diseases.

  13. Thermal cycling tests of 1st wall mock-ups with beryllium/CuCrZr bonding

    International Nuclear Information System (INIS)

    Uda, M.; Iwadachi, T.; Uchida, M.; Yamada, H.; Nakamichi, M.; Kawamura, H.

    2004-01-01

    The innovative bonding technology between beryllium and CuCrZr with Hot Isostatic Pressing (HIP) has been proposed for the manufacturing of the ITER first wall. In the next step, thermal cycling test of first wall mock-ups manufactured with the bonding technology, were carried out under the ITER heat load condition. The test condition is 1000 cycles of On and Off under 5 MW/m 2 , and two types of the mock-up were manufactured for evaluation of the effects on HIP temperature (520 degree C and 610 degree C). The tensile properties of the bonding were also evaluated in room temperature and 200 degree C. As for the results of the thermal cycling tests, the temperature near the bonding interface were scarcely any change up to 1000 cycles, and obvious damage of the mock-up was not detected under the tests. As for the results of the tensile tests in 200 degree C, the test pieces of the HIP bonding at 610 degree C were broken in parent CuCrZr material, not broken in the bonding interface. (author)

  14. A FIRST LOOK AT CREATING MOCK CATALOGS WITH MACHINE LEARNING TECHNIQUES

    International Nuclear Information System (INIS)

    Xu Xiaoying; Ho, Shirley; Trac, Hy; Schneider, Jeff; Ntampaka, Michelle; Poczos, Barnabas

    2013-01-01

    We investigate machine learning (ML) techniques for predicting the number of galaxies (N gal ) that occupy a halo, given the halo's properties. These types of mappings are crucial for constructing the mock galaxy catalogs necessary for analyses of large-scale structure. The ML techniques proposed here distinguish themselves from traditional halo occupation distribution (HOD) modeling as they do not assume a prescribed relationship between halo properties and N gal . In addition, our ML approaches are only dependent on parent halo properties (like HOD methods), which are advantageous over subhalo-based approaches as identifying subhalos correctly is difficult. We test two algorithms: support vector machines (SVM) and k-nearest-neighbor (kNN) regression. We take galaxies and halos from the Millennium simulation and predict N gal by training our algorithms on the following six halo properties: number of particles, M 200 , σ v , v max , half-mass radius, and spin. For Millennium, our predicted N gal values have a mean-squared error (MSE) of ∼0.16 for both SVM and kNN. Our predictions match the overall distribution of halos reasonably well and the galaxy correlation function at large scales to ∼5%-10%. In addition, we demonstrate a feature selection algorithm to isolate the halo parameters that are most predictive, a useful technique for understanding the mapping between halo properties and N gal . Lastly, we investigate these ML-based approaches in making mock catalogs for different galaxy subpopulations (e.g., blue, red, high M star , low M star ). Given its non-parametric nature as well as its powerful predictive and feature selection capabilities, ML offers an interesting alternative for creating mock catalogs

  15. Fabrication of a full-size mock-up for inboard 10o section of ITER vacuum vessel thermal shield

    International Nuclear Information System (INIS)

    Chung, W.; Nam, K.; Noh, C.H.; Kang, D.K.; Kang, S.M.; Oh, Y.G.; Choi, S.W.; Kang, S.H.; Utin, Y.; Ioki, K.; Her, N.; Yu, J.

    2011-01-01

    A full-scale mock-up of VVTS inboard section was made in order to validate its manufacturing processes before manufacturing the vacuum vessel thermal shield (VVTS) for ITER tokamak. VVTS inboard 10 o section consists of 20 mm shells on which cooling tubes are welded and flange joints that connect adjacent thermal shield sectors. The whole VVTS inboard is divided into two by bisectional flange joint located at the center. All the manufacturing processes except silver coating were tested and verified in the fabrication of mock-up. For the forming and the welding, pre-qualification tests were conducted to find proper process conditions. Shell thickness change was measured after bending, forming and buffing processes. Shell distortion was adjusted after the welding. Welding was validated by non-destructive examination. Bisectional flange joint was successfully assembled by inserting pins and tightening with bolt/nut. Bolt hole margin of 2 mm for sector flange was revealed to be sufficient by successful sector assembly of upper and lower parts of mock-up. Handling jig was found to be essential because the inboard section was flexible. Dimensional inspection of the fabricated mock-up was performed with a 3D laser scanner.

  16. [Temperature that modifies the effect of air pollution on emergency room visits for circulatory and respiratory diseases in Beijing, China].

    Science.gov (United States)

    Wang, L L; Zhang, Q; Bai, R H; Mi, B B; Yan, H

    2017-08-10

    Objective: To analyze the temperature modification effect on emergency room visits for circulatory and respiratory diseases caused by air pollution, in Beijing. Methods: Data on both circulatory and respiratory diseases in 2010 and 2011 were collected, Both meteorological and air pollutants related data were obtained from the National Scientific Data Sharing Platform for Population and Health. By using the stratified time-series models, we analyzed the effects of air pollution on emergency room visits for circulatory and respiratory diseases under different temperature zones, from 2010 to 2011, in Beijing. Results: Low temperature (daily average temperatureeffect of air pollution index (API) on emergency room visits for circulatory diseases, Under 10 units of API, the relative risks and confidence interval appeared as 1.067 (1.054-1.080). However, high (daily average temperature between 24.4 ℃ and 28.5 ℃) and extra-high temperature (daily average temperature >28.5 ℃) could enhance the effect of API on emergency room visits for respiratory diseases, Under 10 units of API, the relative risks and confidence interval were 1.021 (1.015-1.028) and 1.006 (1.003-1.008), respectively. Conclusion: Temperature seemed to have modified the association between air pollution and both circulatory and respiratory diseases.

  17. F.B.R. Core mock-up RAPSODIE- I: Experimental analysis

    International Nuclear Information System (INIS)

    Brochard, D.; Buland, P.; Gantenbein, F.

    1990-01-01

    The main phenomena which influence the LMFBR core response to a seismic excitation are the fluid structure interaction and the impacts between subassemblies. To study the core behaviour, seismic tests have been performed on the core mock-up RAPSODIE with or without fluid and restraint ring and for different levels of excitation. This paper summarizes the results of these tests

  18. Extracorporeal circulatory systems in the interhospital transfer of critically ill patients: experience of a single institution

    International Nuclear Information System (INIS)

    Haneya, Assad; Philipp, Alois; Foltan, Maik; Camboni, Daniele; Rupprecht, Leopold; Puehler, Thomas; Hirt, Stephan; Hilker, Michael; Kobuch, Reinhard; Schmid, Christof; Arlt, Matthias; Mueller, Thomas

    2009-01-01

    Critically ill patients with acute circulatory failure cannot be moved to other institutions unless stabilized by mechanical support systems. Extracorporeal heart and lung assist systems are increasingly used as a bridge to end-organ recovery or transplantation, and as an ultimate rescue tool in cardiopulmonary resuscitation. From July 2001 to April 2008, we had 38 requests for extracorporeal support for interhospital transfer carried out by the air medical service. Respiratory failure was present in 29 patients, who were provided with pumpless extracorporeal lung assist (PECLA) or veno-venous extracorporeal membrane oxygenation (ECMO). Cardiac failure dominated in 9 patients, who underwent implantation of extracorporeal life support (ECLS). Underlying diseases were acute respiratory distress syndrome in 15 patients, pneumonia in 7, prior lung transplant status in 4, cardiogenic shock in 7, and septic shock in 4. All assist systems were connected via peripheral vessels by the Seldinger technique. Transport was uneventful in all cases with no technical failures. On arrival at the specialized care hospital, two patients had leg ischemia and underwent relocation of the arterial cannula. After a mean (SD) support of 5.1 (3.0) days for PECLA, 3.5 (2.9) days for ECLS, and 7.3 (5.8) days for ECMO, 60%, 66%, and 66% of patients, respectively, could be successfully weaned from the systems. Discharge rates were 45% for PECLA, 44% for ECLS, and 56% for ECMO. Our experience proves that minimized extracorporeal assist devices allow safe assistance of patients with isolated or combined heart and lung failure in need of interhospital transfer. Critically ill patients get a chance to reach a center of maximum medical care. (author)

  19. The Implications of the Shift Toward Donation After Circulatory Death in Australia

    Directory of Open Access Journals (Sweden)

    Janske Reiling, MD, PhD

    2017-12-01

    Discussion. This study shows that livers donated after circulatory death are an underused resource in Australia. Better use of these currently available organs would be a highly cost-effective way of reducing waiting list mortality in liver transplantation.

  20. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.

    Science.gov (United States)

    Pelletier, Benedikt; Spiliopoulos, Sotirios; Finocchiaro, Thomas; Graef, Felix; Kuipers, Kristin; Laumen, Marco; Guersoy, Dilek; Steinseifer, Ulrich; Koerfer, Reiner; Tenderich, Gero

    2015-01-01

    Owing to the lack of suitable allografts, the demand for long-term mechanical circulatory support in patients with biventricular end-stage heart failure is rising. Currently available Total Artificial Heart (TAH) systems consist of pump units with only limited durability, percutaneous tubes and bulky external equipment that limit the quality of life. Therefore we are focusing on the development of a fully implantable, highly durable destination therapy total artificial heart. The ReinHeart-TAH system consists of a passively filling pump unit driven by a low-wear linear drive between two artificial ventricles, an implantable control unit and a compliance chamber. The TAH is powered by a transcutaneous energy transmission system. The flow distribution inside the ventricles was analysed by fluid structure interaction simulation and particle image velocimetry measurements. Along with durability tests, the hydrodynamic performance and flow balance capability were evaluated in a mock circulation loop. Animal trials are ongoing. Based on fluid structure interaction simulation and particle image velocimetry, blood stagnation areas have been significantly reduced. In the mock circulation loop the ReinHeart-TAH generated a cardiac output of 5 l/min at an operating frequency of 120 bpm and an aortic pressure of 120/80 mmHg. The highly effective preload sensitivity of the passively filling ventricles allowed the sensorless integration of the Frank Starling mechanism. The ReinHeart-TAH effectively replaced the native heart's function in animals for up to 2 days. In vitro and in vivo testing showed a safe and effective function of the ReinHeart-TAH system. This has the potential to become an alternative to transplantation. However, before a first-in-man implant, chronic animal trials still have to be completed. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Sensitivity and uncertainty analyses of the HCLL mock-up experiment

    International Nuclear Information System (INIS)

    Leichtle, D.; Fischer, U.; Kodeli, I.; Perel, R.L.; Klix, A.; Batistoni, P.; Villari, R.

    2010-01-01

    Within the European Fusion Technology Programme dedicated computational methods, tools and data have been developed and validated for sensitivity and uncertainty analyses of fusion neutronics experiments. The present paper is devoted to this kind of analyses on the recent neutronics experiment on a mock-up of the Helium-Cooled Lithium Lead Test Blanket Module for ITER at the Frascati neutron generator. They comprise both probabilistic and deterministic methodologies for the assessment of uncertainties of nuclear responses due to nuclear data uncertainties and their sensitivities to the involved reaction cross-section data. We have used MCNP and MCSEN codes in the Monte Carlo approach and DORT and SUSD3D in the deterministic approach for transport and sensitivity calculations, respectively. In both cases JEFF-3.1 and FENDL-2.1 libraries for the transport data and mainly ENDF/B-VI.8 and SCALE6.0 libraries for the relevant covariance data have been used. With a few exceptions, the two different methodological approaches were shown to provide consistent results. A total nuclear data related uncertainty in the range of 1-2% (1σ confidence level) was assessed for the tritium production in the HCLL mock-up experiment.

  2. Inference on white dwarf binary systems using the first round Mock LISA Data Challenges data sets

    International Nuclear Information System (INIS)

    Stroeer, Alexander; Veitch, John; Roever, Christian; Bloomer, Ed; Clark, James; Christensen, Nelson; Hendry, Martin; Messenger, Chris; Meyer, Renate; Pitkin, Matthew; Toher, Jennifer; Umstaetter, Richard; Vecchio, Alberto; Woan, Graham

    2007-01-01

    We report on the analysis of selected single source data sets from the first round of the mock LISA data challenges (MLDC) for white dwarf binaries. We implemented an end-to-end pipeline consisting of a grid-based coherent pre-processing unit for signal detection and an automatic Markov Chain Monte Carlo (MCMC) post-processing unit for signal evaluation. We demonstrate that signal detection with our coherent approach is secure and accurate, and is increased in accuracy and supplemented with additional information on the signal parameters by our Markov Chain Monte Carlo approach. We also demonstrate that the Markov Chain Monte Carlo routine is additionally able to determine accurately the noise level in the frequency window of interest

  3. Analysis of high heat flux testing of mock-ups

    International Nuclear Information System (INIS)

    Salavy, J.-F.; Giancarli, L.; Merola, M.; Picard, F.; Roedig, M.

    2003-01-01

    ITER EU Home Team is performing a large R and D effort in support of the development of high heat flux components for ITER. In this framework, this paper describes the thermal analyses, the fatigue lifetime evaluation and the transient VDE with material melting related to the high heat flux thermo-mechanical tests performed in the JUDITH facility. It reports on several mock-ups representative of different proposed component designs based on Be, W and CFC as armour materials

  4. powerbox: Arbitrarily structured, arbitrary-dimension boxes and log-normal mocks

    Science.gov (United States)

    Murray, Steven G.

    2018-05-01

    powerbox creates density grids (or boxes) with an arbitrary two-point distribution (i.e. power spectrum). The software works in any number of dimensions, creates Gaussian or Log-Normal fields, and measures power spectra of output fields to ensure consistency. The primary motivation for creating the code was the simple creation of log-normal mock galaxy distributions, but the methodology can be used for other applications.

  5. [Cerebral oximetry in pulmonary thromboendarterectomy with circulatory arrest].

    Science.gov (United States)

    Catalán Escudero, P; González Román, A; Serra Ruiz, C N; Barbero Mielgo, M; García Fernández, J

    2014-02-01

    Pulmonary thromboendarterectomy is an uncommon procedure and should be performed with circulatory arrest. One of the major concerns is the postoperative central neurological injuries. Perioperative brain oxygen monitoring is advisable in this surgical procedure for the early detection of brain hypoperfusion episodes and their intensity as well as any other postoperative episodes that can deteriorate the neurological outcome. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  6. Validation results of satellite mock-up capturing experiment using nets

    Science.gov (United States)

    Medina, Alberto; Cercós, Lorenzo; Stefanescu, Raluca M.; Benvenuto, Riccardo; Pesce, Vincenzo; Marcon, Marco; Lavagna, Michèle; González, Iván; Rodríguez López, Nuria; Wormnes, Kjetil

    2017-05-01

    The PATENDER activity (Net parametric characterization and parabolic flight), funded by the European Space Agency (ESA) via its Clean Space initiative, was aiming to validate a simulation tool for designing nets for capturing space debris. This validation has been performed through a set of different experiments under microgravity conditions where a net was launched capturing and wrapping a satellite mock-up. This paper presents the architecture of the thrown-net dynamics simulator together with the set-up of the deployment experiment and its trajectory reconstruction results on a parabolic flight (Novespace A-310, June 2015). The simulator has been implemented within the Blender framework in order to provide a highly configurable tool, able to reproduce different scenarios for Active Debris Removal missions. The experiment has been performed over thirty parabolas offering around 22 s of zero-g conditions. Flexible meshed fabric structure (the net) ejected from a container and propelled by corner masses (the bullets) arranged around its circumference have been launched at different initial velocities and launching angles using a pneumatic-based dedicated mechanism (representing the chaser satellite) against a target mock-up (the target satellite). High-speed motion cameras were recording the experiment allowing 3D reconstruction of the net motion. The net knots have been coloured to allow the images post-process using colour segmentation, stereo matching and iterative closest point (ICP) for knots tracking. The final objective of the activity was the validation of the net deployment and wrapping simulator using images recorded during the parabolic flight. The high-resolution images acquired have been post-processed to determine accurately the initial conditions and generate the reference data (position and velocity of all knots of the net along its deployment and wrapping of the target mock-up) for the simulator validation. The simulator has been properly

  7. A FIRST LOOK AT CREATING MOCK CATALOGS WITH MACHINE LEARNING TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Xu Xiaoying; Ho, Shirley; Trac, Hy; Schneider, Jeff; Ntampaka, Michelle [McWilliams Center for Cosmology, Department of Physics, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States); Poczos, Barnabas [School of Computer Science, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA 15213 (United States)

    2013-08-01

    We investigate machine learning (ML) techniques for predicting the number of galaxies (N{sub gal}) that occupy a halo, given the halo's properties. These types of mappings are crucial for constructing the mock galaxy catalogs necessary for analyses of large-scale structure. The ML techniques proposed here distinguish themselves from traditional halo occupation distribution (HOD) modeling as they do not assume a prescribed relationship between halo properties and N{sub gal}. In addition, our ML approaches are only dependent on parent halo properties (like HOD methods), which are advantageous over subhalo-based approaches as identifying subhalos correctly is difficult. We test two algorithms: support vector machines (SVM) and k-nearest-neighbor (kNN) regression. We take galaxies and halos from the Millennium simulation and predict N{sub gal} by training our algorithms on the following six halo properties: number of particles, M{sub 200}, {sigma}{sub v}, v{sub max}, half-mass radius, and spin. For Millennium, our predicted N{sub gal} values have a mean-squared error (MSE) of {approx}0.16 for both SVM and kNN. Our predictions match the overall distribution of halos reasonably well and the galaxy correlation function at large scales to {approx}5%-10%. In addition, we demonstrate a feature selection algorithm to isolate the halo parameters that are most predictive, a useful technique for understanding the mapping between halo properties and N{sub gal}. Lastly, we investigate these ML-based approaches in making mock catalogs for different galaxy subpopulations (e.g., blue, red, high M{sub star}, low M{sub star}). Given its non-parametric nature as well as its powerful predictive and feature selection capabilities, ML offers an interesting alternative for creating mock catalogs.

  8. Speaking with (Dis)respect: A Study of Reactions to Mock Spanish

    Science.gov (United States)

    Callahan, Laura

    2010-01-01

    This paper reports on an investigation into the reactions of 147 participants of various ethnicities to a language practice in the USA that has been characterized as Mock Spanish, a special register in which Spanish words or phrases are used to evoke humor by indexing an often unflattering image of Spanish speakers. Research questions include…

  9. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    International Nuclear Information System (INIS)

    Harris, S.P.

    1997-01-01

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock-up Facility using 3 ml inserts and 15 ml peanut vials. A number of the insert samples were analyzed by Cold Chem and compared with full peanut vial samples analyzed by the current methods. The remaining inserts were analyzed by

  10. Evaluation on sweep gas pressure drop in fusion blanket mock-up for in-pile test

    International Nuclear Information System (INIS)

    Ishitsuka, Etsuo; Kawamura, Hiroshi; Sagawa, Hisashi; Nagakura, Masaaki; Kanzawa, Toru.

    1993-03-01

    In the ITER/CDA (Conceptual Design Activity) of a tritium breeding blanket, Japan have proposed the pebble-typed blanket. The in-pile mock-up test will be preparing in JMTR (Japan Materials Testing Reactor) for Japanese engineering design with the pebble-typed blanket. Therefore, the He sweep gas pressure drop in the pebble bed was measured for the design of the mock-up used on in-pile test. From the results of this test, it was clear that the pressure drop was predicted on Kozeny- Carman's equation within +25 ∼ -60 %, and that the pressure drop was not affected by moisture concentration (< 100 ppm). (author)

  11. Evaluation on sweep gas pressure drop in fusion blanket mock-up for in-pile test

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, Etsuo; Kawamura, Hiroshi; Sagawa, Hisashi (Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment); Nagakura, Masaaki; Kanzawa, Toru.

    1993-03-01

    In the ITER/CDA (Conceptual Design Activity) of a tritium breeding blanket, Japan have proposed the pebble-typed blanket. The in-pile mock-up test will be preparing in JMTR (Japan Materials Testing Reactor) for Japanese engineering design with the pebble-typed blanket. Therefore, the He sweep gas pressure drop in the pebble bed was measured for the design of the mock-up used on in-pile test. From the results of this test, it was clear that the pressure drop was predicted on Kozeny- Carman's equation within +25 [approx] -60 %, and that the pressure drop was not affected by moisture concentration (< 100 ppm). (author).

  12. Evaluation on sweep gas pressure drop in fusion blanket mock-up for in-pile test

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, Etsuo; Kawamura, Hiroshi; Sagawa, Hisashi [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Nagakura, Masaaki; Kanzawa, Toru

    1993-03-01

    In the ITER/CDA (Conceptual Design Activity) of a tritium breeding blanket, Japan have proposed the pebble-typed blanket. The in-pile mock-up test will be preparing in JMTR (Japan Materials Testing Reactor) for Japanese engineering design with the pebble-typed blanket. Therefore, the He sweep gas pressure drop in the pebble bed was measured for the design of the mock-up used on in-pile test. From the results of this test, it was clear that the pressure drop was predicted on Kozeny- Carman`s equation within +25 {approx} -60 %, and that the pressure drop was not affected by moisture concentration (< 100 ppm). (author).

  13. Selective cerebral perfusion prevents abnormalities in glutamate cycling and neuronal apoptosis in a model of infant deep hypothermic circulatory arrest and reperfusion.

    Science.gov (United States)

    Kajimoto, Masaki; Ledee, Dolena R; Olson, Aaron K; Isern, Nancy G; Robillard-Frayne, Isabelle; Des Rosiers, Christine; Portman, Michael A

    2016-11-01

    Deep hypothermic circulatory arrest is often required for the repair of complex congenital cardiac defects in infants. However, deep hypothermic circulatory arrest induces neuroapoptosis associated with later development of neurocognitive abnormalities. Selective cerebral perfusion theoretically provides superior neural protection possibly through modifications in cerebral substrate oxidation and closely integrated glutamate cycling. We tested the hypothesis that selective cerebral perfusion modulates glucose utilization, and ameliorates abnormalities in glutamate flux, which occur in association with neuroapoptosis during deep hypothermic circulatory arrest. Eighteen infant male Yorkshire piglets were assigned randomly to two groups of seven (deep hypothermic circulatory arrest or deep hypothermic circulatory arrest with selective cerebral perfusion for 60 minutes at 18℃) and four control pigs without cardiopulmonary bypass support. Carbon-13-labeled glucose as a metabolic tracer was infused, and gas chromatography-mass spectrometry and nuclear magnetic resonance were used for metabolic analysis in the frontal cortex. Following 2.5 h of cerebral reperfusion, we observed similar cerebral adenosine triphosphate levels, absolute levels of lactate and citric acid cycle intermediates, and carbon-13 enrichment among three groups. However, deep hypothermic circulatory arrest induced significant abnormalities in glutamate cycling resulting in reduced glutamate/glutamine and elevated γ-aminobutyric acid/glutamate along with neuroapoptosis, which were all prevented by selective cerebral perfusion. The data suggest that selective cerebral perfusion prevents these modifications in glutamate/glutamine/γ-aminobutyric acid cycling and protects the cerebral cortex from apoptosis. © The Author(s) 2016.

  14. The state of the art report on the fabrication of FW blanket for the fusion reactor and mock-up development in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Whan; Baek, Jong Hyuk; Park, Jeong Yong; Kim, Hyun Gil; Jeong, Yong Hwan

    2004-08-01

    Blanket-shield system in ITER is the component where it directly is faced with high-heat plasma. Function of blanket is to sustain extremely high temperature environment as well as to remove heat flux generated its surface. It mainly consists of plasma facing part, heat sinking part and structural part. Plasma facing part is made of armour materials such as beryllium, tungsten and carbon fiber composite. Heat sinking part is made of copper alloy to maximize heat transfer into flowing coolant inside of blanket. Structural material is used in 316LN stainless steel. As joining such dissimilar materials emerged as an issue, many developed countries have spurred the development of joint technology. This technical report was focused on the activities of EU regarding joining beryllium, copper and stainless steel. EU have adopted to Hot Isostatic Pressing (HIP) to join beryllium, copper and stainless steel. Although brazing process is not actively investigated compared as HIP, it still investigated in some countries to support HIP. Fabrication of mock-up is accomplished by CEA in France to finish small scale mock-up in 1996, medium and large scale mock-up in 1997. In recent, FRAMATOME in EU has focused on manufacturing prototype used for ITER.

  15. The state of the art report on the fabrication of FW blanket for the fusion reactor and mock-up development in Europe

    International Nuclear Information System (INIS)

    Kim, Jun Whan; Baek, Jong Hyuk; Park, Jeong Yong; Kim, Hyun Gil; Jeong, Yong Hwan

    2004-08-01

    Blanket-shield system in ITER is the component where it directly is faced with high-heat plasma. Function of blanket is to sustain extremely high temperature environment as well as to remove heat flux generated its surface. It mainly consists of plasma facing part, heat sinking part and structural part. Plasma facing part is made of armour materials such as beryllium, tungsten and carbon fiber composite. Heat sinking part is made of copper alloy to maximize heat transfer into flowing coolant inside of blanket. Structural material is used in 316LN stainless steel. As joining such dissimilar materials emerged as an issue, many developed countries have spurred the development of joint technology. This technical report was focused on the activities of EU regarding joining beryllium, copper and stainless steel. EU have adopted to Hot Isostatic Pressing (HIP) to join beryllium, copper and stainless steel. Although brazing process is not actively investigated compared as HIP, it still investigated in some countries to support HIP. Fabrication of mock-up is accomplished by CEA in France to finish small scale mock-up in 1996, medium and large scale mock-up in 1997. In recent, FRAMATOME in EU has focused on manufacturing prototype used for ITER

  16. Generating mock data sets for large-scale Lyman-α forest correlation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Font-Ribera, Andreu [Institut de Ciències de l' Espai (CSIC-IEEC), Campus UAB, Fac. Ciències, torre C5 parell 2, Bellaterra, Catalonia (Spain); McDonald, Patrick [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Miralda-Escudé, Jordi, E-mail: font@ieec.uab.es, E-mail: pvmcdonald@lbl.gov, E-mail: miralda@icc.ub.edu [Institució Catalana de Recerca i Estudis Avançats, Barcelona, Catalonia (Spain)

    2012-01-01

    Massive spectroscopic surveys of high-redshift quasars yield large numbers of correlated Lyα absorption spectra that can be used to measure large-scale structure. Simulations of these surveys are required to accurately interpret the measurements of correlations and correct for systematic errors. An efficient method to generate mock realizations of Lyα forest surveys is presented which generates a field over the lines of sight to the survey sources only, instead of having to generate it over the entire three-dimensional volume of the survey. The method can be calibrated to reproduce the power spectrum and one-point distribution function of the transmitted flux fraction, as well as the redshift evolution of these quantities, and is easily used for modeling any survey systematic effects. We present an example of how these mock surveys are applied to predict the measurement errors in a survey with similar parameters as the BOSS quasar survey in SDSS-III.

  17. Generating mock data sets for large-scale Lyman-α forest correlation measurements

    International Nuclear Information System (INIS)

    Font-Ribera, Andreu; McDonald, Patrick; Miralda-Escudé, Jordi

    2012-01-01

    Massive spectroscopic surveys of high-redshift quasars yield large numbers of correlated Lyα absorption spectra that can be used to measure large-scale structure. Simulations of these surveys are required to accurately interpret the measurements of correlations and correct for systematic errors. An efficient method to generate mock realizations of Lyα forest surveys is presented which generates a field over the lines of sight to the survey sources only, instead of having to generate it over the entire three-dimensional volume of the survey. The method can be calibrated to reproduce the power spectrum and one-point distribution function of the transmitted flux fraction, as well as the redshift evolution of these quantities, and is easily used for modeling any survey systematic effects. We present an example of how these mock surveys are applied to predict the measurement errors in a survey with similar parameters as the BOSS quasar survey in SDSS-III

  18. CIRCULATORY FAILURE DURING NON-INHALED FORMS OF CYANIDE INTOXICATION

    Science.gov (United States)

    Haouzi, Philippe; Tubbs, Nicole; Rannals, Matthew D.; Judenherc-Haouzi, Annick; Cabell, Larry A.; McDonough, Joe A.; Sonobe, Takashi

    2016-01-01

    Our objective was to determine how circulatory failure develops following systemic administration of potassium cyanide (KCN). We used a non-inhaled modality of intoxication, wherein the change in breathing pattern would not influence the diffusion of CN into the blood, akin to the effects of ingesting toxic levels of CN. In a group of 300–400 g rats, CN-induced coma (CN IP, 7 mg/kg) produced a central apnea within 2–3 minutes along with a potent and prolonged gasping pattern leading to auto-resuscitation in 38% of the animals. Motor deficits and neuronal necrosis were nevertheless observed in the surviving animals. To clarify the mechanisms leading to potential auto-resuscitation versus asystole, 12 urethane-anesthetized rats were then exposed to the lowest possible levels of CN exposure that would lead to breathing depression within 7–8 minutes; this dose averaged 0.375 mg/kg/min iv. At this level of intoxication, a cardiac depression developed several minutes only after the onset of the apnea, leading to cardiac asystole as PaO2 reached value around 15 Torr, unless breathing was maintained by mechanical ventilation or through spontaneous gasping. Higher levels of KCN exposure in 10 animals provoked a primary cardiac depression, which led to a rapid cardiac arrest by pulseless electrical activity despite the maintenance of PaO2 by mechanical ventilation. These effects were totally unrelated to the potassium contained in KCN. It is concluded that circulatory failure can develop as a direct consequence of CN induced apnea but in a narrow range of exposure. In this “low” range, maintaining pulmonary gas exchange after exposure, through mechanical ventilation (or spontaneous gasping) can reverse cardiac depression and restore spontaneous breathing. At higher level of intoxication, cardiac depression is to be treated as a specific and spontaneously irreversible consequence of CN exposure, leading to a pulseless electrical activity. PMID:27513083

  19. Manufacturing, testing and post-test examination of ITER divertor vertical target W small scale mock-ups

    International Nuclear Information System (INIS)

    Visca, Eliseo; Cacciotti, Emanuele; Komarov, Anton; Libera, Stefano; Litunovsky, Nikolay; Makhankov, Alexey; Mancini, Andrea; Merola, Mario; Pizzuto, Aldo; Riccardi, Bruno; Roccella, Selanna

    2011-01-01

    ENEA is involved in the International Thermonuclear Experimental Reactor (ITER) R and D activities. During the last years ENEA has set up and widely tested a manufacturing process, named Hot Radial Pressing (HRP), suitable for the construction of high heat flux plasma-facing components, such as the divertor targets. In the frame of the EFDA contract six mock-ups were manufactured by HRP in the ENEA labs using W monoblocks supplied by the Efremov Institute in St. Petersburg, Russian Federation and IG CuCrZr tubes. According to the technical specifications the mock-ups were examined by ultrasonic technique and after their acceptance they were delivered to the Efremov Institute TSEFEY-M e-beam facility for the thermal fatigue testing. The test consisted in 3000 cycles of 15 s heating and 15 s cooling at 10 MW/m 2 and finally 1000 cycles at 20 MW/m 2 . After the testing the ultrasonic non-destructive examination was repeated and the results compared with the investigation performed before the testing. A microstructure modification of the W monoblock material due to the overheating of the surfaces and the copper interlayer structure modification were observed in the high heat flux area. The leakage points of the mock-ups that did not conclude the testing were localized in the middle of the monoblock while they were expected between two monoblocks. This paper reports the manufacturing route, the thermal fatigue testing, the pre and post non destructive examination and finally the results of the destructive examination performed on the monoblock small scale mock-ups.

  20. Theological reflections on donation after circulatory death: the wisdom of Paul Ramsey and Moshe Feinstein.

    Science.gov (United States)

    Jotkowitz, A

    2008-10-01

    Due to the worldwide shortage of organs for transplantation, there has been an increased use of organs obtained after circulatory death alone. A protocol for this procedure has recently been approved by a major transplant consortium. This development raises serious moral and ethical concerns. Two renowned theologians of the previous generation, Paul Ramsey and Moshe Feinstein, wrote extensively on the ethical issues relating to transplantation, and their work has much relevance to current moral dilemmas. Their writings relating to definition of death, organ transplantation and the care of the terminally ill are briefly presented, and their potential application to the moral problem of organ donation after circulatory death is discussed.

  1. The application of multiple intelligence approach to the learning of human circulatory system

    Science.gov (United States)

    Kumalasari, Lita; Yusuf Hilmi, A.; Priyandoko, Didik

    2017-11-01

    The purpose of this study is to offer an alternative teaching approach or strategies which able to accommodate students’ different ability, intelligence and learning style. Also can gives a new idea for the teacher as a facilitator for exploring how to teach the student in creative ways and more student-center activities, for a lesson such as circulatory system. This study was carried out at one private school in Bandung involved eight students to see their responses toward the lesson that delivered by using Multiple Intelligence approach which is include Linguistic, Logical-Mathematical, Visual-Spatial, Musical, Bodily-Kinesthetic, Interpersonal, Intrapersonal, and Naturalistic. Students were test by using MI test based on Howard Gardner’s MI model to see their dominant intelligence. The result showed the percentage of top three ranks of intelligence are Bodily-Kinesthetic (73%), Visual-Spatial (68%), and Logical-Mathematical (61%). The learning process is given by using some different multimedia and activities to engaged their learning style and intelligence such as mini experiment, short clip, and questions. Student response is given by using self-assessment and the result is all students said the lesson gives them a knowledge and skills that useful for their life, they are clear with the explanation given, they didn’t find difficulties to understand the lesson and can complete the assignment given. At the end of the study, it is reveal that the students who are learned by Multiple Intelligence instructional approach have more enhance to the lesson given. It’s also found out that the students participated in the learning process which Multiple Intelligence approach was applied enjoyed the activities and have great fun.

  2. ISSUES AND FEASIBILITY DEMONSTRATION OF CLIC SUPPORTING SYSTEM CHAIN ACTIVE PRE-ALIGNMENT USING A MULTI-MODULE TEST SETUP (MOCK-UP)

    CERN Document Server

    Sosin, Mateusz

    2016-01-01

    The implementation study of the CLIC (Compact LInear Collider) is under way at CERN with a focus on the challenging issues. The pre-alignment precision and accuracy requirements are part of these technical challenges: the permissible transverse position errors of the linac components are typically 14 micrometers over sliding windows of 200m. To validate the proposed methods and strategies, the Large Scale Metrology section at CERN has performed campaigns of measurements on the CLIC Two Beam Test Modules, focusing inter alia on the alignment performance of the CLIC “snake”- girders configuration and the Main Beam Quadrupoles supporting structures. This paper describes the activities and results of tests which were performed on the test mock-up for the qualification of the CLIC supporting system chain for active pre-alignment. The lessons learnt (“know how”), the issues encountered in the girder position determination as well as the behaviour of the mechanical components are presented.

  3. Circulatory Arrest: A Surgical Option for Adult Window Ductus Closure

    Directory of Open Access Journals (Sweden)

    Vithalkumar Malleshi Betigeri

    2012-03-01

    Full Text Available The window ductus , an atypical type of patent ductus arteriosus(PDA is a characteristically large in size(>2cm with no recognizable length, characteristic continuation of main pulmonary artery with aortic arch and absence of internal ductal tissue. Surgical safety and effectiveness of its closure can be increased by using cardiopulmonary bypass (CPB and hypothermic total circulatory arrest (HTCA via median sternotomy.

  4. "But He's a Star Football Player!": How Social Status Influences Mock Jurors' Perceptions in a Sexual Assault Case.

    Science.gov (United States)

    Pica, Emily; Sheahan, Chelsea; Pozzulo, Joanna

    2017-06-01

    There have been several recent, high-profile cases in the media that have shed light on the perceived leniency in sentencing defendants in sexual assault cases. In a number of these cases, the defendant was well known within their community (e.g., Brock Turner; People v. Turner) or nationally (e.g., Ghomeshi; R v. Ghomeshi). The purpose of this study was to examine how the social status of the defendant (low vs. high), victim social status (low vs. high), victim gender (male vs. female), and the reason the victim was unconscious during the assault (consuming alcohol vs. consuming cold medicine) influenced mock jurors' decisions in a sexual assault case. Mock jurors ( N = 489) read a mock trial transcript depicting an alleged sexual assault. Mock jurors were asked to render a dichotomous verdict, continuous guilt rating, and rate their perceptions of the victim and defendant. There was no influence of the variables on mock jurors' dichotomous verdicts; however, social status influenced guilt ratings. There also was a combined influence of the defendant's social status and the reason the victim was unconscious such that when the defendant was described as low status, and the victim was unconscious due to alcohol consumption, the defendant received higher guilt ratings compared with when the victim was unconscious due to cold medicine. Moreover, the victim was perceived as having more control over the situation when the defendant was the star quarterback (i.e., high status), the victim was female, and she was unconscious due to alcohol consumption compared with cold medicine. These results suggest that victims may be blamed based on their perceived social status and other factors that may have influenced their control over the sexual assault, such as alcohol consumption.

  5. Superconformal algebras and mock theta functions

    International Nuclear Information System (INIS)

    Eguchi, Tohru; Hikami, Kazuhiro

    2009-01-01

    It is known that characters of BPS representations of extended superconformal algebras do not have good modular properties due to extra singular vectors coming from the BPS condition. In order to improve their modular properties we apply the method of Zwegers which has recently been developed to analyze modular properties of mock theta functions. We consider the case of the N=4 superconformal algebra at general levels and obtain the decomposition of characters of BPS representations into a sum of simple Jacobi forms and an infinite series of non-BPS representations. We apply our method to study elliptic genera of hyper-Kaehler manifolds in higher dimensions. In particular, we determine the elliptic genera in the case of complex four dimensions of the Hilbert scheme of points on K3 surfaces K [2] and complex tori A [[3

  6. Superconformal algebras and mock theta functions

    Energy Technology Data Exchange (ETDEWEB)

    Eguchi, Tohru [Yukawa Institute for Theoretical Physics, Kyoto University, Kyoto 606-8502 (Japan); Hikami, Kazuhiro [Department of Mathematics, Naruto University of Education, Tokushima 772-8502 (Japan)], E-mail: eguchi@yukawa.kyoto-u.ac.jp, E-mail: hikami@naruto-u.ac.jp

    2009-07-31

    It is known that characters of BPS representations of extended superconformal algebras do not have good modular properties due to extra singular vectors coming from the BPS condition. In order to improve their modular properties we apply the method of Zwegers which has recently been developed to analyze modular properties of mock theta functions. We consider the case of the N=4 superconformal algebra at general levels and obtain the decomposition of characters of BPS representations into a sum of simple Jacobi forms and an infinite series of non-BPS representations. We apply our method to study elliptic genera of hyper-Kaehler manifolds in higher dimensions. In particular, we determine the elliptic genera in the case of complex four dimensions of the Hilbert scheme of points on K3 surfaces K{sup [2]} and complex tori A{sup [[3

  7. Pathophysiology of cerebral circulatory disorders in idiopathic normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Takeuchi, Totaro; Goto, Hiromi; Izaki, Kenji

    2007-01-01

    This study was conducted to elucidate the pathologic conditions of cerebral circulatory disorders in idiopathic normal pressure hydrocephalus (iNPH). Among 44 possible iNPH patients, 40 patients underwent shunt surgery based on diagnostic flow charts plotted by the Southern Tohoku method and were evaluated to be shunt-effective at the end of the first post-surgical month. The cerebral blood flow (CBF) was measured by N-isopropyl-( 123 I)-P-iodo-amphetamine single photon emission computed tomography (mean, mCBF; cortical region, cCBF; thalamus-basal ganglia region, tbCBF on autoradiography [ARG] method) and the perfusion patterns of the cerebral cortex were measured based on three-dimensional stereotactic surface projection (3D-SSP) Z-score images, before and 1 month after the surgery in all 40 subjects. The mCBF rose significantly from 32.1±2.74 ml/100 g/min before surgery to 39.8±3.02 ml/100 g/min after surgery (p<0.03). Investigation of the change of CBF revealed reductions in the cCBF (3 cases), tbCBF (9 cases), and cCBF+tbCBF (28 cases), with the reduced-cCBF group totaling 31 cases and the reduced-tbCBF group totaling 37 cases. Investigation of cerebral cortex hypoperfusion by 3D-SSP Z-score revealed 31 cases with hypoperfusion (frontal lobe type [19 cases], occipitotemporal lobe type [5 cases], mixed type [7 cases]) and nine cases with cortical normoperfusion (N). The pattern of reduction of the cortical blood flow on ARG method was favorably correlated with the pattern of hypoperfusion of the cerebral cortex on 3D-SSP Z-score images before surgery. A reduction of blood flow was found in the thalamus-basal ganglia region of all N type cases. The blood flow improved in 19 of 31 (61.3%) cases of the reduced-cCBF group and in 32 of 37 (86.5%) cases of the reduced-tbCBF group. All of the cases without detectable improvement exhibited increased blood flow in non-reduction areas. Investigation of the hypoperfusion patterns of the cerebral cortex on 3D-SSP Z

  8. Heart Transplant and Mechanical Circulatory Support in Patients With Advanced Heart Failure.

    Science.gov (United States)

    Sánchez-Enrique, Cristina; Jorde, Ulrich P; González-Costello, José

    2017-05-01

    Patients with advanced heart failure have a poor prognosis and heart transplant is still the best treatment option. However, the scarcity of donors, long waiting times, and an increasing number of unstable patients have favored the development of mechanical circulatory support. This review summarizes the indications for heart transplant, candidate evaluation, current immunosuppression strategies, the evaluation and treatment of rejection, infectious prophylaxis, and short and long-term outcomes. Regarding mechanical circulatory support, we distinguish between short- and long-term support and the distinct strategies that can be used: bridge to decision, recovery, candidacy, transplant, and destination therapy. We then discuss indications, risk assessment, management of complications, especially with long-term support, and outcomes. Finally, we discuss future challenges and how the widespread use of long-term support for patients with advanced heart failure will only be viable if their complications and costs are reduced. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  9. A SCALE-UP Mock-Up: Comparison of Student Learning Gains in High- and Low-Tech Active-Learning Environments

    Science.gov (United States)

    Soneral, Paula A. G.; Wyse, Sara A.

    2017-01-01

    Student-centered learning environments with upside-down pedagogies (SCALE-UP) are widely implemented at institutions across the country, and learning gains from these classrooms have been well documented. This study investigates the specific design feature(s) of the SCALE-UP classroom most conducive to teaching and learning. Using pilot survey data from instructors and students to prioritize the most salient SCALE-UP classroom features, we created a low-tech “Mock-up” version of this classroom and tested the impact of these features on student learning, attitudes, and satisfaction using a quasi-­experimental setup. The same instructor taught two sections of an introductory biology course in the SCALE-UP and Mock-up rooms. Although students in both sections were equivalent in terms of gender, grade point average, incoming ACT, and drop/fail/withdraw rate, the Mock-up classroom enrolled significantly more freshmen. Controlling for class standing, multiple regression modeling revealed no significant differences in exam, in-class, preclass, and Introduction to Molecular and Cellular Biology Concept Inventory scores between the SCALE-UP and Mock-up classrooms. Thematic analysis of student comments highlighted that collaboration and whiteboards enhanced the learning experience, but technology was not important. Student satisfaction and attitudes were comparable. These results suggest that the benefits of a SCALE-UP experience can be achieved at lower cost without technology features. PMID:28213582

  10. Nitroglycerin reverts clinical manifestations of poor peripheral perfusion in patients with circulatory shock

    NARCIS (Netherlands)

    A.A.P. Lima (Alexandre ); M.E. van Genderen (Michel); J. van Bommel (Jasper); E. Klijn (Elko); T. Jansem (Tim); J. Bakker (Jan)

    2014-01-01

    textabstractIntroduction: Recent clinical studies have shown a relationship between abnormalities in peripheral perfusion and unfavorable outcome in patients with circulatory shock. Nitroglycerin is effective in restoring alterations in microcirculatory blood flow. The aim of this study was to

  11. Thermo-siphon Mock-up Test for the HANARO-CNS

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jungwoon; Lee, Kye Hong; Kim, Hark Rho; Kim, Youngki; Kim, Myong Seop; Wu, Sang Ik; Kim, Bong Su

    2006-04-15

    In order to moderate thermal neutrons into cold neutrons, the liquid hydrogen is selected as a moderator for the HANARO CNS. By the non-nuclear heat load and nuclear heat load induced from collision of gamma-ray, beta-ray, and thermal neutrons, the liquid hydrogen in the moderator cell evaporates and flows into the heat exchanger. This evaporated hydrogen gas is liquefied by the cryogenic helium supplied from the helium refrigeration system,, then flows back to the moderator cell. This is so-called two-phase thermo-siphon. The most important point in the stable thermo-siphon is to have the good balance between the cooling capacity of the HRS and the heat load on the moderator cell so as to maintain the stable two-phase liquid level in the moderator cell. Accordingly, for not only the experience of the cryogenic two-phase thermo-siphon but also setup of the operation procedure, the full-scaled mock-up test has been performed using the liquid hydrogen. Through the test, the stable thermo-siphon establishment is confirmed at the cold normal operation; furthermore, the detail design parameter is validated. On top of the normal operation procedure setup, the abnormal operation procedure is settled based on the understanding the abnormal pressure and temperature transient dynamics in the hydrogen system.

  12. The state of art of the manufacturing technology of FW blanket and the development of mock-up for fusion reactor in Russia

    International Nuclear Information System (INIS)

    Baek, Jong Hyuk; Jeong, Y. H.; Park, J. Y.; Kim, J. H.; Kim, H. G.

    2004-08-01

    In early 1990s, Russia had carried out the performance tests to verify the optimization of Be tile geometry and the bonding integrity of small mock-up using a HHF (High Heat Flux) test and an in-pile test in a research reactor. They had obtained the reliability of the brazing technologies for the Be/Cu bonding. And they had manufactured the near real-size large mock-up (about 0.8 mm in length) to find the bonding integrity by a fast brazing technique. They had a satisfied results from the HHF test for the large mock-up. Additionally, an alternative FW mock-ups, which were manufactured by both casting and fast brazing techniques to reduce the joining parts, showed a good joining performance from the HHF test. Therefore, it was concluded that the fast brazing techniques could be strongly recommended as a one of the preferable joining techniques and be possible to apply to joining for the Be/Cu joining of FW blanket

  13. [Mechanical circulatory support in pediatrics. Experience at the Dr. Juan P. Garrahan Pediatric Hospital. Argentina].

    Science.gov (United States)

    Moreno, Guillermo E; Magliola, Ricardo; Pilán, María Luisa; Althabe, María; Balestrini, María; Lenz, Ana Miriam; Krysnki, Mariela; Rodríguez, Ricardo; Salgado, Gladys; Martin, Analía; Cardoso, Hugo; Ruffa, Pablo; Cornelis, Carlos Javier; Barreta, Jorge; García Delucis, Pablo

    2014-01-01

    Mechanical circulatory support provides oxygen to the tissues in patients with cardiac and/or respiratory reversible disease refractory to conventional treatments. The aim of this study is to show our initial results of mechanical circulatory support in children with heart disease. Retrospective cohort between March 2006 and March 2012. Demographic data (age, sex, weight, cardiac diagnosis), surgery (technique, pump, aortic cross clamping time) and mechanical circulatory support (type of assistance, indication, duration, complications and outcome) were collected. Thirty-three patients were supported (1.3% of all surgeries), extracorporeal membrane oxygenation 32 cases and one ventricular assist device. The median age 7.4 months (one day-18 years) and weight 6kg (2.3-75). The most frequent cardiac malformations supported were the transpositions of the great arteries associated with other anomalies and the corrected transpositions (ventricular inversion or double discordance). The most common reason for admission was post-cardiotomy biventricular dysfunction. Twenty-eight patients were supported in the postoperative period, 4 in the preoperative period and in one with myocarditis. Median days of support were 3 days (1-10). The most common complications were infection (21%), bleeding (21%). Elective decannulation was achieved in 94% of cases. Hospital discharge survival: 52%. The mechanical circulatory support in our institution is a safe and standard procedure. We have been using it in a small number of cases with a similar survival to that reported internationally. This complex procedure is widely justified because it allows for the recovery of more than half of the patients who otherwise would have died. Copyright © 2013 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  14. Accurate halo-galaxy mocks from automatic bias estimation and particle mesh gravity solvers

    Science.gov (United States)

    Vakili, Mohammadjavad; Kitaura, Francisco-Shu; Feng, Yu; Yepes, Gustavo; Zhao, Cheng; Chuang, Chia-Hsun; Hahn, ChangHoon

    2017-12-01

    Reliable extraction of cosmological information from clustering measurements of galaxy surveys requires estimation of the error covariance matrices of observables. The accuracy of covariance matrices is limited by our ability to generate sufficiently large number of independent mock catalogues that can describe the physics of galaxy clustering across a wide range of scales. Furthermore, galaxy mock catalogues are required to study systematics in galaxy surveys and to test analysis tools. In this investigation, we present a fast and accurate approach for generation of mock catalogues for the upcoming galaxy surveys. Our method relies on low-resolution approximate gravity solvers to simulate the large-scale dark matter field, which we then populate with haloes according to a flexible non-linear and stochastic bias model. In particular, we extend the PATCHY code with an efficient particle mesh algorithm to simulate the dark matter field (the FASTPM code), and with a robust MCMC method relying on the EMCEE code for constraining the parameters of the bias model. Using the haloes in the BigMultiDark high-resolution N-body simulation as a reference catalogue, we demonstrate that our technique can model the bivariate probability distribution function (counts-in-cells), power spectrum and bispectrum of haloes in the reference catalogue. Specifically, we show that the new ingredients permit us to reach percentage accuracy in the power spectrum up to k ∼ 0.4 h Mpc-1 (within 5 per cent up to k ∼ 0.6 h Mpc-1) with accurate bispectra improving previous results based on Lagrangian perturbation theory.

  15. SECURING DIGITIZED LIBRARY CIRCULATORY SYSTEM

    African Journals Online (AJOL)

    user

    The widespread application of the developed system on smart library circulation .... database management system; [9] through securing .... system running on a Windows 8 Operating system .... mini library for their support, advice and unlimited.

  16. Validation of a Micrometric remotely controlled pre-alignment system for the CLIC Linear Collider using a test setup (Mock-Up) with 5 degrees of freedom

    CERN Document Server

    Mainaud Durand, H; Griffet, S; Kemppinen, J; Leuxe, R; Sosin, M

    2011-01-01

    The CLIC main beam quadrupoles need to be prealigned within 17 um rms with respect to a straight reference line along a sliding window of 200 m. A readjustment system based on eccentric cam movers, which will provide stiffness to the support assembly, is being studied. The cam movers were qualified on a 1 degree of freedom (DOF) test setup, where a repeatability of adjustment below 1um was measured along their whole range. This paper presents the 5 DOF mock-up, built for the validation of the eccentric cam movers, as well as the first results of tests carried out: resolution of displacement along the whole range, measurements of the support eigenfrequencies.

  17. A Soft Total Artificial Heart-First Concept Evaluation on a Hybrid Mock Circulation.

    Science.gov (United States)

    Cohrs, Nicholas H; Petrou, Anastasios; Loepfe, Michael; Yliruka, Maria; Schumacher, Christoph M; Kohll, A Xavier; Starck, Christoph T; Schmid Daners, Marianne; Meboldt, Mirko; Falk, Volkmar; Stark, Wendelin J

    2017-10-01

    The technology of 3D-printing has allowed the production of entirely soft pumps with complex chamber geometries. We used this technique to develop a completely soft pneumatically driven total artificial heart from silicone elastomers and evaluated its performance on a hybrid mock circulation. The goal of this study is to present an innovative concept of a soft total artificial heart (sTAH). Using the form of a human heart, we designed a sTAH, which consists of only two ventricles and produced it using a 3D-printing, lost-wax casting technique. The diastolic properties of the sTAH were defined and the performance of the sTAH was evaluated on a hybrid mock circulation under various physiological conditions. The sTAH achieved a blood flow of 2.2 L/min against a systemic vascular resistance of 1.11 mm Hg s/mL (afterload), when operated at 80 bpm. At the same time, the mean pulmonary venous pressure (preload) was fixed at 10 mm Hg. Furthermore, an aortic pulse pressure of 35 mm Hg was measured, with a mean aortic pressure of 48 mm Hg. The sTAH generated physiologically shaped signals of blood flow and pressures by mimicking the movement of a real heart. The preliminary results of this study show a promising potential of the soft pumps in heart replacements. Further work, focused on increasing blood flow and in turn aortic pressure is required. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Plasma cleaning of ITER edge Thomson scattering mock-up mirror in the EAST tokamak

    Science.gov (United States)

    Yan, Rong; Moser, Lucas; Wang, Baoguo; Peng, Jiao; Vorpahl, Christian; Leipold, Frank; Reichle, Roger; Ding, Rui; Chen, Junling; Mu, Lei; Steiner, Roland; Meyer, Ernst; Zhao, Mingzhong; Wu, Jinhua; Marot, Laurent

    2018-02-01

    First mirrors are the key element of all optical and laser diagnostics in ITER. Facing the plasma directly, the surface of the first mirrors could be sputtered by energetic particles or deposited with contaminants eroded from the first wall (tungsten and beryllium), which would result in the degradation of the reflectivity. The impurity deposits emphasize the necessity of the first mirror in situ cleaning for ITER. The mock-up first mirror system for ITER edge Thomson scattering diagnostics has been cleaned in EAST for the first time in a tokamak using radio frequency capacitively coupled plasma. The cleaning properties, namely the removal of contaminants and homogeneity of cleaning were investigated with molybdenum mirror insets (25 mm diameter) located at five positions over the mock-up plate (center to edge) on which 10 nm of aluminum oxide, used as beryllium proxy, were deposited. The cleaning efficiency was evaluated using energy dispersive x-ray spectroscopy, reflectivity measurements and x-ray photoelectron spectroscopy. Using argon or neon plasma without magnetic field in the laboratory and with a 1.7 T magnetic field in the EAST tokamak, the aluminum oxide films were homogeneously removed. The full recovery of the mirrors’ reflectivity was attained after cleaning in EAST with the magnetic field, and the cleaning efficiency was about 40 times higher than that without the magnetic field. All these results are promising for the plasma cleaning baseline scenario of ITER.

  19. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH{sub 4} + H{sub 2}O {yields} 3H{sub 2}O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m{sup 3}{sub N}/h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  20. Performance test results of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system. Contract research

    International Nuclear Information System (INIS)

    Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio

    2003-03-01

    Research on a hydrogen production system by steam reforming of methane, chemical reaction; CH 4 + H 2 O → 3H 2 O + CO, has been carried out to couple with the HTTR for establishment of high-temperature nuclear heat utilization technology and contribution to hydrogen energy society in future. The mock-up test facility with a full-scale reaction tube test facility, a model simulating one reaction tube of a steam reformer of the HTTR hydrogen production system in full scale, was fabricated to perform tests on controllability, hydrogen production performance etc. under the same pressure and temperature conditions as those of the HTTR hydrogen production system. The design and fabrication of the test facility started from 1997, and the all components were installed until September in 2001. In a performance test conducted from October in 2001 to February in 2002, performance of each component was examined and hydrogen of 120m 3 N /h was successfully produced with high-temperature helium gas. This report describes the performance test results on components performance, hydrogen production characteristics etc., and main troubles and countermeasures. (author)

  1. COCOA Code for Creating Mock Observations of Star Cluster Models

    OpenAIRE

    Askar, Abbas; Giersz, Mirek; Pych, Wojciech; Dalessandro, Emanuele

    2017-01-01

    We introduce and present results from the COCOA (Cluster simulatiOn Comparison with ObservAtions) code that has been developed to create idealized mock photometric observations using results from numerical simulations of star cluster evolution. COCOA is able to present the output of realistic numerical simulations of star clusters carried out using Monte Carlo or \\textit{N}-body codes in a way that is useful for direct comparison with photometric observations. In this paper, we describe the C...

  2. Manufacturing and testing of W/Cu mono-block small scale mock-up for EAST by HIP and HRP technologies

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qiang [Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP), Hefei, Anhui (China); Qin, Sigui [Advanced Technology and Materials Co., Ltd, Beijing (China); Wang, Wanjing; Qi, Pan [Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP), Hefei, Anhui (China); Roccella, Selanna; Visca, Eliseo [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy); Liu, Guohui [Advanced Technology and Materials Co., Ltd, Beijing (China); Luo, Guang-Nan, E-mail: liqiang577@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP), Hefei, Anhui (China)

    2013-10-15

    ITER-like W/Cu mono-block plasma-facing components (PFCs) will be used in vertical target regions of the experimental advanced superconducting tokamak (EAST) divertor. The first W/Cu mono-block small scale mock-up with five W mono-blocks has been manufactured successfully by technological combination of hot isostatic pressing (HIP) and hot radial pressing (HRP). The joining of a W mono-block and a pure copper interlayer was achieved by means of HIP technology and the bonding strength was over 150 MPa. The good bonding between the pure copper interlayer and a CuCrZr cooling tube was obtained by means of HRP technology. In order to understand deeply the process of HRP, the stress distribution of the mock-up during HRP process was simulated using ANSYS code. Ultrasonic Nondestructive Testing (NDT) of the W/Cu and Cu/CuCrZr interfaces was performed, showing that excellent bonding of the W/Cu and Cu/CuCrZr interfaces. The thermal cycle fatigue testing of the mock-up has been carried out by means of an e-beam device in Southwest Institute of Physics, Chengdu (SWIP) and the mock-up withstood 1000 cycles of heat loads up to 8.4 MW/m{sup 2} with the cooling water of 2 m/s, 20 °C, 0.2 MPa.

  3. Non destructive examination of primary wall small scale mock-up DS-1F

    International Nuclear Information System (INIS)

    Jeskanen, H.; Lahdenperae, K.; Kauppinen, P.; Taehtinen, S.

    1998-06-01

    Ultrasonic examination of primary wall small scale mock up DS-1F before thermal testing showed no major defects on studied interfaces. However, some small indications were found on copper to copper and copper to steel interfaces and surface roughness of the outer surface of copper layer gave clear indications on ultrasonic images. After thermal test a curved 50 mm long crack along the Y- direction in the middle of the heated surface of the mock up and a 220 mm long crack along the copper to copper interface on the side surface of the mock up were detected. Small cracks, less than 60-80 μm in depth, were observed on copper surface. After thermal test the corresponding ultrasonic examination showed a strong effect on ultrasonic attenuation properties and on leaky Rayleigh waves on outer surface of copper layer. A major indication was found on copper to copper interface. About 50% of the copper to copper interface was delaminated. However, some small indications found already before thermal test were also found after thermal test and they were not grown in size. No indications were observed on copper to stainless steel interfaces. Additionally, major indications were found on stainless steel tube to copper interfaces. Tubes No. 1 and 2 were almost completely whereas tube No. 3 only partly separated from copper. No indications were found on stainless steel tube to copper interface on tube No. 4. Eddy current measurements showed no volumetric or crack like flaws in the stainless steel tubes, however, delamination of the copper to copper interface along the tubes No. 1, 2 and 3 was observed. (orig.)

  4. Generalized derivation of the added-mass and circulatory forces for viscous flows

    Science.gov (United States)

    Limacher, Eric; Morton, Chris; Wood, David

    2018-01-01

    The concept of added mass arises from potential flow analysis and is associated with the acceleration of a body in an inviscid irrotational fluid. When shed vorticity is modeled as vortex singularities embedded in this irrotational flow, the associated force can be superimposed onto the added-mass force due to the linearity of the governing Laplace equation. This decomposition of force into added-mass and circulatory components remains common in modern aerodynamic models, but its applicability to viscous separated flows remains unclear. The present work addresses this knowledge gap by presenting a generalized derivation of the added-mass and circulatory force decomposition which is valid for a body of arbitrary shape in an unbounded, incompressible fluid domain, in both two and three dimensions, undergoing arbitrary motions amid continuous distributions of vorticity. From the general expression, the classical added-mass force is rederived for well-known canonical cases and is seen to be additive to the circulatory force for any flow. The formulation is shown to be equivalent to existing theoretical work under the specific conditions and assumptions of previous studies. It is also validated using a numerical simulation of a pitching plate in a steady freestream flow, conducted by Wang and Eldredge [Theor. Comput. Fluid Dyn. 27, 577 (2013), 10.1007/s00162-012-0279-5]. In response to persistent confusion in the literature, a discussion of the most appropriate physical interpretation of added mass is included, informed by inspection of the derived equations. The added-mass force is seen to account for the dynamic effect of near-body vorticity and is not (as is commonly claimed) associated with the acceleration of near-body fluid which "must" somehow move with the body. Various other consequences of the derivation are discussed, including a concept which has been labeled the conservation of image-vorticity impulse.

  5. Delayed Referral Results in Missed Opportunities for Organ Donation After Circulatory Death.

    Science.gov (United States)

    Krmpotic, Kristina; Payne, Clare; Isenor, Cynthia; Dhanani, Sonny

    2017-06-01

    Rates of organ donation and transplantation have steadily increased in the United States and Canada over the past decade, largely attributable to a notable increase in donation after circulatory death. However, the number of patients awaiting solid organ transplantation continues to remain much higher than the number of organs transplanted each year. The objective of this study was to determine the potential to increase donation rates further by identifying gaps in the well-established donation after circulatory death process in Ontario. Retrospective cohort study. Provincial organ procurement organization. Patients who died in designated donation hospitals within the province of Ontario, Canada between April 1, 2013, and March 31, 2015. None. Of 1,407 patient deaths following planned withdrawal of life-sustaining therapy, 54.0% (n = 760) were medically suitable for donation after circulatory death. In 438 cases where next of kin was approached, consent rates reached 47.5%. A total of 119 patients became actual organ donors. Only 66.2% (n = 503) of suitable patients were appropriately referred, resulting in 251 missed potential donors whose next of kin could not be approached regarding organ donation because referral occurred after initiation of withdrawal of life-sustaining therapy or not at all. The number of medically suitable patients who die within 2 hours of planned withdrawal of life-sustaining therapy is nearly six times higher than the number of actual organ donors, with the greatest loss of potential due to delayed referral until at the time of or after planned withdrawal of life-sustaining therapy. Intensive care teams are not meeting their ethical responsibility to recognize impending death and appropriately refer potential organ donors to the local organ procurement organization. In cases where patients had previously registered their consent decision, they were denied a healthcare right.

  6. Manufacturing of In-Pile Test Section(IPS) Mock-up for the 3-Pin Fuel Test Loop

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. M.; Park, K. N.; Chi, D. Y. (and others)

    2005-10-15

    Manufacturing process of IPS Mock-up was initiated in late of 2003 with DAEWOO Precision industries Company. Manufacturing drawings due to detail drawings are composed of Outer assembly and Inner assembly. Welding of IPS Mock-up was performed by the GMAW(Gas Metal Arc Welding) process. After the welding process, non-destructive examination was conducted. Leak test was performed to the Main cooling water part and Neon gas inter-space gap part by the He gas injection with the pressure of 6.0 kg{sub f}/cm{sup 2} and 30 minutes holding time. the result was shown that there was no leak at the Neon gas inter-space gap part but leak was occurred at Main cooling water part according to imperfect screw of purge plug. so, it was re-finished and test was performed to certify the leak tightness. To satisfy the HANARO Limiting Operation Condition, IPS should be tested ahead of installation at the HANARO reactor by the use of test facilities. IPS Mock-up and its test facilities will be designed and used for the test of 'HANARO flow tube pressure drop', 'IPS inner pressure drop' and 'IPS inner vibration'.

  7. Realisation of a test facility for the ITER ICRH antenna plug-in by means of a mock-up with salted water load

    International Nuclear Information System (INIS)

    Messiaen, A.; Dumortier, P.; Koch, R.; Lamalle, P.; Louche, F.; Martini, J.L.; Vervier, M.

    2005-01-01

    By the use of a mock-up operated at higher frequency it is possible to measure with good accuracy the rf characteristics of an ICRH antenna, the plasma loading being simulated by a water tank in front of it. This concept has motivated the construction of the mock-up of the antenna array foreseen for ITER

  8. Manufacturing of a HCLL cooling plate mock up

    International Nuclear Information System (INIS)

    Rigal, E.; Dinechin, G. de; Rampal, G.; Laffont, G.; Cachon, L.

    2007-01-01

    The European DEMO blankets and associated Test Blanket Modules (TBM) are made of a set of components cooled by flowing helium at 80bar pressure. Hot Isostatic Pressing (HIP) is one of the very few processes that allow manufacturing such components exhibiting complex cooling channels. In HIP technology, the parts used to manufacture components with embedded channels are usually machined plates, blocks and tubes. Achievable geometries are limited in shape because it is not always possible to figure the channels by bent tubes. This occurs for example when channels present sharp turns, when the cross section of the channels is rectangular or when the rib between channels is so small that very thin tubes would be required. In these cases, bending is unpractical. The breeder unit cooling plates of the Helium Cooled Lithium Lead (HCLL) blanket have eight 4 x 4.5 mm parallel channels that run following a double U scheme. Turns are sharp and the wall thickness is small (1mm), so the manufacturing process described above cannot be used. An alternative process has been developed which has many advantages. It consists in machining grooves in a base plate, then closing the top of the grooves using thin welded strips, and finally adding a plate by HIP. There is then no need for the use of tubes with associated bending and deformation issues. The final component contains welds, but it must be stressed out that these potentially brittle zones do not connect the channels to the external surface because they are covered by the HIPed plate. Furthermore, the welds are homogenised during the HIP operation and further heat treatments. This paper describes the design of a simplified cooling plate mock up and its fabrication using this so-called weld+HIP process. The thermal fatigue testing of this mock up is presented somewhere else in this conference. (orig.)

  9. Nuclear-fueled circulatory support systems

    Energy Technology Data Exchange (ETDEWEB)

    Norman, J C [Texas Heart Inst. (USA)

    1975-08-01

    Experiments on calves using two types of systems for nuclear left ventricular assist pumps are described. These two systems use a nuclear heat source containing 120 g, 1600 Ci Pu-238 in the form of plutonium oxide. The heat source for the first system is the tidal regenerator engine with no valve or seal and is controlled using a hall effect displacement sensor. The second left ventricular assist system uses heat generated by nuclear decay for producing high gas pressure which is converted into a high hydraulic pressure for pumping. The engine efficiency amounts to 7 to 16%, and the measurement value of the pump efficiency obtained is 85%. How these two systems are synchronized with the left ventricle of vital body is described. IN a transplant experiment for a short period (175 hours) in the initial stage, the possibility of the present method was demonstrated. A long-term performance experiment and improvement of the systems are anticipated. However, there still remain many problems, such as improvement of efficiency, reliability, and performance and diminution of the size.

  10. Comparison of polygraph data obtained from individuals involved in mock crimes and actual criminal investigations.

    Science.gov (United States)

    Pollina, Dean A; Dollins, Andrew B; Senter, Stuart M; Krapohl, Donald J; Ryan, Andrew H

    2004-12-01

    In a preliminary attempt to determine the generalizability of data from laboratory mock-crime studies, the authors examined the similarities and differences among the cardiovascular, electrodermal, and respiration responses of deceptive and nondeceptive individuals elicited to crime-relevant and crime-irrelevant questions. Participants in the laboratory group were randomly assigned to nondeceptive (n = 28) or deceptive (n = 27) treatment groups, and a mock-crime scenario was used. The field participants were confirmed nondeceptive (n = 28) or deceptive (n = 39) criminal suspects who underwent polygraph examinations between 1993 and 1997. The results indicated that there were salient differences between field and similarly obtained laboratory polygraph response measures. However, accuracy of laboratory participants' classifications using logistic regression analysis was not significantly different from field participants' classification accuracy. 2004 APA, all rights reserved

  11. Overview of the EU small scale mock-up tests for ITER high heat flux components

    International Nuclear Information System (INIS)

    Vieider, G.; Barabash, V.; Cardella, A.

    1998-01-01

    This task within the EU R and D for ITER was aimed at the development of basic manufacturing solutions for the high heat flux plasma facing components such as the divertor targets, the baffles and limiters. More than 50 representative small-scale mock-ups have been manufactured with beryllium, carbon and tungsten armour using various joining technologies. High heat flux testing of 20 of these mock-ups showed the carbon mono-blocks to be the most robust solution, surviving 2000 cycles at absorbed heat fluxes of up to 24 MW m -2 . With flat armour tiles rapid joint failures occurred at 5-16 MW m -2 depending on joining technology and armour material. These test results serve as a basis for the selection of manufacturing options and materials for the prototypes now being ordered. (orig.)

  12. Cardiorespiratory interactions in neural circulatory control in humans.

    Science.gov (United States)

    Shamsuzzaman, A S; Somers, V K

    2001-06-01

    The reflex mechanisms and interactions described in this overview provide some explanation for the range of neural circulatory responses evident during changes in breathing. The effects described represent the integrated responses to activation of several reflex mechanisms, including peripheral and central chemoreflexes, arterial baroreflexes, pulmonary stretch receptors, and ventricular mechanoreceptors. These interactions occur on a dynamic basis and the transfer characteristics of any single interaction are, in all likelihood, also highly dynamic. Nevertheless, it is only by attempting to understand individual reflexes and their modulating influences that a more thorough understanding of the responses to complex phenomena such as hyperventilation, apnea, and obstructive sleep apnea can be better understood.

  13. Pre-brazed casting and hot radial pressing: A reliable process for the manufacturing of CFC and W monoblock mock-ups

    International Nuclear Information System (INIS)

    Visca, Eliseo; Libera, S.; Mancini, A.; Mazzone, G.; Pizzuto, A.; Testani, C.

    2007-01-01

    ENEA is involved in the European International Thermonuclear Experimental Reactor (ITER) R and D activities and, in particular, for the manufacturing of high heat flux plasma-facing components (HHFC), such as the divertor targets, the baffles and the limiters. During last years, ENEA has manufactured actively cooled mock-ups by using different technologies, namely brazing, diffusion bonding and hot isostatic pressing (HIPping). A new manufacturing process has been set up and tested. It was successfully applied for the manufacturing of W armoured monoblock mock-ups. This technique is the HRP (hot radial pressing) based on performing a radial diffusion bonding between the cooling tube and the armour tile by pressurizing only internal tube and by keeping the joining zone in vacuum at the required bonding temperature. The heating is obtained by a standard air furnace. The HRP technique is now used for the manufacturing of CFC armoured monoblock components. For this purpose, some issues have to be faced, like the low CFC tensile strength, the pure copper interlayer between the heat sink and the armour necessary to mitigate the stress at the joint interface, and the low wettability of the pure copper on the CFC matrix. This paper reports the research path followed to manufacture a medium scale vertical target CFC and W armoured mock-up by HRP. A casting of a soft copper interlayer between the tube and the tile was obtained by a new technique: the pre-brazed casting (PBC, ENEA patent). Some preliminary mock-ups with three NB31 CFC tiles were successfully manufactured and tested to thermal fatigue using electron beam facilities. They all reached at least 1000 cycles at 20 MW/m 2 without suffering any damage. The manufactured medium scale vertical target mock-up is now under testing at the FE2000 (France) facility. These activities were performed in the frame of ITER-EFDA contracts

  14. Energy transmission and power sources for mechanical circulatory support devices to achieve total implantability.

    Science.gov (United States)

    Wang, Jake X; Smith, Joshua R; Bonde, Pramod

    2014-04-01

    Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Test of a Mock Theft Scenario for Use in the Psychophysiological Detection of Deception: IV

    National Research Council Canada - National Science Library

    2001-01-01

    .... In Experiments 1 and 2 two groups of 16 participants who were assigned to be either guilty or innocent of the mock theft of a ring were tested using the Zone Comparison Test, a PDD examination taught...

  16. FEATURES OF LONG-TERM MECHANICAL CIRCULATORY SUPPORT WITH CONTINUOUS-FLOW PUMP

    Directory of Open Access Journals (Sweden)

    G. P. Itkin

    2012-01-01

    Full Text Available In a review of the comparative analysis of methods and tools for long-term mechanical circulatory support with continuous flow and pulsatile flow implantable pumps. Particular attention is paid to the choice of the optimal modes of the operation of pumps based on the physical principles of the interaction between a the steady flow of blood to the pulsatile mechanics of the heart chambers. 

  17. The First Organ-Based Ontology for Arthropods (Ontology of Arthropod Circulatory Systems - OArCS) and its Integration into a Novel Formalization Scheme for Morphological Descriptions.

    Science.gov (United States)

    Wirkner, Christian S; Göpel, Torben; Runge, Jens; Keiler, Jonas; Klussmann-Fricke, Bastian-Jesper; Huckstorf, Katarina; Scholz, Stephan; Mikó, István; J Yoder, Matthew; Richter, Stefan

    2017-09-01

    Morphology, the oldest discipline in the biosciences, is currently experiencing a renaissance in the field of comparative phenomics. However, morphological/phenotypic research still suffers on various levels from a lack of standards. This shortcoming, first highlighted as the "linguistic problem of morphology", concerns the usage of terminology and also the need for formalization of morphological descriptions themselves, something of paramount importance not only to the field of morphology but also when it comes to the use of phenotypic data in systematics and evolutionary biology. We therefore argue, that for morphological descriptions, the basis of all systematic and evolutionary interpretations, ontologies need to be utilized which are based exclusively on structural qualities/properties and which in no case include statements about homology and/or function. Statements about homology and function constitute interpretations on a different or higher level. Based on these "anatomy ontologies", further ontological dimensions (e.g., referring to functional properties or homology) may be exerted for a broad use in evolutionary phenomics. To this end we present the first organ-based ontology for the most species-rich animal group, the Arthropoda. Our Ontology of Arthropod Circulatory Systems (OArCS) contains a comprehensive collection of 383 terms (i.e., labels) tied to 296 concepts (i.e., definitions) collected from the literature on phenotypic aspects of circulatory organ features in arthropods. All of the concepts used in OArCS are based exclusively on structural features, and in the context of the ontology are independent of homology and functional assumptions. We cannot rule out that in some cases, terms are used which in traditional usage and previous accounts might have implied homology and/or function (e.g. heart, sternal artery). Concepts are composed of descriptive elements that are used to classify observed instances into the organizational framework of the

  18. Hypothermic Oxygenated Machine Perfusion in Porcine Donation After Circulatory Determination of Death Liver Transplant

    NARCIS (Netherlands)

    Fondevila, Constantino; Hessheimer, Amelia J.; Maathuis, Mark-Hugo J.; Munoz, Javier; Taura, Pilar; Calatayud, David; Leuvenink, Henri; Rimola, Antoni; Garcia-Valdecasas, Juan C.; Ploeg, Rutger J.

    2012-01-01

    Background. Livers from donation after circulatory determination-of-death (DCD) donors suffer ischemic injury during a preextraction period of cardiac arrest and are infrequently used for transplantation; they have the potential, however, to considerably expand the donor pool. We aimed to determine

  19. Comparison of outcomes of kidney transplantation from donation after brain death, donation after circulatory death, and donation after brain death followed by circulatory death donors.

    Science.gov (United States)

    Chen, Guodong; Wang, Chang; Ko, Dicken Shiu-Chung; Qiu, Jiang; Yuan, Xiaopeng; Han, Ming; Wang, Changxi; He, Xiaoshun; Chen, Lizhong

    2017-11-01

    There are three categories of deceased donors of kidney transplantation in China, donation after brain death (DBD), donation after circulatory death (DCD), and donation after brain death followed by circulatory death (DBCD) donors. The aim of this study was to compare the outcomes of kidney transplantation from these three categories of deceased donors. We retrospectively reviewed 469 recipients who received deceased kidney transplantation in our hospital from February 2007 to June 2015. The recipients were divided into three groups according to the source of their donor kidneys: DBD, DCD, or DBCD. The primary endpoints were delayed graft function (DGF), graft loss, and patient death. The warm ischemia time was much longer in DCD group compared to DBCD group (18.4 minutes vs 12.9 minutes, P < .001). DGF rate was higher in DCD group than in DBD and DBCD groups (22.5% vs 10.2% and 13.8%, respectively, P = .021). Urinary leakage was much higher in DCD group (P = .049). Kaplan-Meier analysis showed that 1-, 2-, and 3-year patient survivals were all comparable among the three groups. DBCD kidney transplantation has lower incidences of DGF and urinary leakage than DCD kidney transplant. However, the overall patient and graft survival were comparable among DBD, DCD, and DBCD kidney transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Annual report on experimental operation of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system in 2001 fiscal year (Contract research)

    International Nuclear Information System (INIS)

    Hayashi, Koji; Inagaki, Yoshiyuki; Kato, Michio; Fujisaki, Katsuo; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Inaba, Yoshitomo; Ohashi, Hirofumi; Katanishi, Shoji; Takada, Shoji; Shimizu, Akira; Morisaki, Norihiro; Sakaki, Akihiro; Maeda, Yukimasa; Sato, Hiroyuki

    2005-06-01

    This is an annual report on the experimental operation of the mock-up test facility with a full-scale reaction tube for the HTTR hydrogen production system in 2001 fiscal year. The first experimental operation was performed during two weeks from March 1, 2002 to March 13, 2002 to test on the thermal hydraulic performance of the steam reformer and also to train the operators. The thermal hydraulic performance test of the steam reformer was performed to evaluate the heat transfer characteristics between helium gas and process gas in the steam reformer. This report is summarized with an overview of the test, the results and its operation records. (author)

  1. Preparation of W/CuCrZr monoblock test mock-up using vacuum brazing technique

    International Nuclear Information System (INIS)

    Singh, Kongkham Premjit; Khirwadkar, Samir S.; Bhope, Kedar; Patel, Nikunj; Mokaria, Prakash K.; Mehta, Mayur

    2015-01-01

    Development of the joining for W/CuCrZr monoblock PFC test mock-up is an interest area in Fusion R and D. W/Cu bimetallic material has prepared using OFHC copper casting approach on the radial surface of W monoblock tile surface. The W/Cu bimetallic material has been joined with CuCrZr tube (heat sink) material with the vacuum brazing route. Vacuum brazing of W/Cu-CuCrZr has been performed @ 970 °C for 10 mins using NiCuMn-37 filler material under deep vacuum environment (10 -6 mbar). Graphite fixtures were used for OFHC copper casting and vacuum brazing experiments. The joint integrity of W/Cu-CuCrZr monoblock mock-up on W/Cu and Cu-CuCrZr has been checked using ultrasonic immersion technique. Micro-structural examination and Spot-wise elemental analysis have been carried out using HR-SEM and EDAX. The results of the experimental work will be discussed in the paper. (author)

  2. Surface Modifications of Polymeric Materials for Application in Artificial Heart and Circulatory Assist Devices

    NARCIS (Netherlands)

    Feijen, J.; Engbers, G.H.M.; Terlingen, J.G.A.; van Delden, C.J.; Poot, A.A.; Vaudaux, P.; Akutsu, Tetsuzo; Koyanagi, Hitoshi

    1996-01-01

    Several methods have been developed to modify the surfaces of materials used in artificial hearts and circulatory assist devices to suppress the host response, especially with respect to the occurrence of clotting, cellular damage, and infections. In this review, special attention is paid to

  3. DWPF Sample Vial Insert Study-Statistical Analysis of DWPF Mock-Up Test Data

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.P. [Westinghouse Savannah River Company, AIKEN, SC (United States)

    1997-09-18

    This report is prepared as part of Technical/QA Task Plan WSRC-RP-97-351 which was issued in response to Technical Task Request HLW/DWPF/TTR-970132 submitted by DWPF. Presented in this report is a statistical analysis of DWPF Mock-up test data for evaluation of two new analytical methods which use insert samples from the existing HydragardTM sampler. The first is a new hydrofluoric acid based method called the Cold Chemical Method (Cold Chem) and the second is a modified fusion method.Either new DWPF analytical method could result in a two to three fold improvement in sample analysis time.Both new methods use the existing HydragardTM sampler to collect a smaller insert sample from the process sampling system. The insert testing methodology applies to the DWPF Slurry Mix Evaporator (SME) and the Melter Feed Tank (MFT) samples.The insert sample is named after the initial trials which placed the container inside the sample (peanut) vials. Samples in small 3 ml containers (Inserts) are analyzed by either the cold chemical method or a modified fusion method. The current analytical method uses a HydragardTM sample station to obtain nearly full 15 ml peanut vials. The samples are prepared by a multi-step process for Inductively Coupled Plasma (ICP) analysis by drying, vitrification, grinding and finally dissolution by either mixed acid or fusion. In contrast, the insert sample is placed directly in the dissolution vessel, thus eliminating the drying, vitrification and grinding operations for the Cold chem method. Although the modified fusion still requires drying and calcine conversion, the process is rapid due to the decreased sample size and that no vitrification step is required.A slurry feed simulant material was acquired from the TNX pilot facility from the test run designated as PX-7.The Mock-up test data were gathered on the basis of a statistical design presented in SRT-SCS-97004 (Rev. 0). Simulant PX-7 samples were taken in the DWPF Analytical Cell Mock

  4. Issues and Feasibility Demonstration of Positioning Closed Loop Control for the CLIC Supporting System Using a Test Mock-up with Five Degrees of Freedom

    CERN Document Server

    Sosin, M; Chritin, N; Griffet, S; Kemppinen, J; Mainaud Durand, H; Rude, V; Sterbini, G

    2012-01-01

    Since several years, CERN is studying the feasibility of building a high energy e+ e- linear collider: the CLIC (Compact LInear Collider). One of the challenges of such a collider is the pre-alignment precision and accuracy requirement on the transverse positions of the linac components, which is typically 14 μm over a window of 200 m. To ensure the possibility of positioning within such tight constraints, CERN Beams Department’s Survey team has worked intensively at developing the methods and technology needed to achieve that objective. This paper describes activities which were performed on a test bench (mock-up) with five degrees of freedom (DOF) for the qualification of control algorithms for the CLIC supporting system active-pre-alignment. Present understanding, lessons learned (“know how”), issues of sensors noise and mechanical components nonlinearities are presented.

  5. Measurement and analysis of neutron flux spectra in a neutronics mock-up of the HCLL test blanket module

    International Nuclear Information System (INIS)

    Klix, A.; Batistoni, P.; Boettger, R.; Lebrun-Grandie, D.; Fischer, U.; Henniger, J.; Leichtle, D.; Villari, R.

    2010-01-01

    Fast neutron and gamma-ray flux spectra and time-of-arrival spectra of slow neutrons have been measured in a neutronics mock-up of the European Helium-Cooled Lithium-Lead Test Blanket Module with the aim to validate nuclear cross-section data. The mock-up was irradiated with fusion peak neutrons from the DT neutron generator of the Technical University of Dresden. A well characterized cylindrical NE-213 scintillator was inserted into two positions in the LiPb/EUROFER assembly. Pulse height spectra from neutrons and gamma-rays were recorded from the NE-213 output. The spectra were then unfolded with experimentally obtained response matrices of the NE-213 detector. Time-of-arrival spectra of slow neutrons were measured with a 3 He counter placed in the mock-up, and the neutron generator was operated in pulsed mode. Monte Carlo calculations using the MCNP code and nuclear cross-section data from the JEFF-3.1.1 and FENDL-2.1 libraries were performed and the results are compared with the experimental results. A good agreement of measurement and calculation was found with some deviations in certain energy intervals.

  6. Non-invasive estimation of pulsatile flow and differential pressure in an implantable rotary blood pump for heart failure patients

    International Nuclear Information System (INIS)

    AlOmari, A H; Savkin, A V; Karantonis, D M; Lim, E; Lovell, N H

    2009-01-01

    We propose dynamical models for pulsatile flow and head estimation in an implantable rotary blood pump. Pulsatile flow and head data were obtained using a circulatory mock loop where fluid solutions with different values of viscosities were used as a blood analogue with varying haematocrit (HCT). Noninvasive measurements of power and pump speed were used with HCT values as inputs to the flow model while the estimated flow was used with the speed as inputs to a head estimation model. Linear regression analysis between estimated and measured flows obtained from a mock loop resulted in a highly significant correlation (R 2 = 0.982) and a mean absolute error (e) of 0.323 L min −1 , while for head, R 2 = 0.933 and e = 7.682 mmHg were obtained. R 2 = 0.849 and e = 0.584 L min −1 were obtained when the same model derived in the mock loop was used for flow estimation in ex vivo porcine data (N = 6). Furthermore, in the steady state, the solution of the presented flow model can be described by a previously designed and verified static model. The models developed herein will play a vital role in developing a robust control system of the pump flow coping with changing physiological demands

  7. Minimal alteration in the ratio of circulatory fetal DNA to fetal corticotropin-releasing hormone mRNA level in preeclampsia.

    Science.gov (United States)

    Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe

    2006-01-01

    We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.

  8. HHF test with 80x80x1 Be/Cu/SS Mock-ups for verifying the joining technology of the ITER blanket First Wall

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Won; Bae, Young Dug; Kim, Suk Kwon; Hong, Bong Guen; Jeong, Yong Hwan; Park, Jeong Yong; Choi, Byung Kwon; Jung, Hyun Kyu

    2008-11-15

    Through the fabrication of the Cu/SS and Be/Cu joint specimens, fabrication procedure such as material preparation, canning, degassing, HIP (Hot Isostatic Pressing), PHHT (Post HIP heat treatment) was established. The HIP conditions (1050 .deg. C, 100 MPa 2 hr for Cu/SS, 580 .deg. C 100 MPa 2 hr for Be/Cu) were developed through the investigation on joint specimen fabricated with the various HIP conditions; the destructive tests of joint include the microstructure observation of the interface with the examination of the elemental distribution, tension test, bend test, Charpy impact test and fracture toughness test. However, since the joint should be tested under the High Heat Flux (HHF) conditions like the ITER operation for verifying its joint integrity, several HHF tests were performed like the previous HHF test with the Cu/SS, Be/Cu, Be/Cu/SS Mock-ups. In the present study, the HHF test with Be/Cu/SS Mock-ups, which have 80 mm x 80 mm single Be tile and each material depths were kept to be the same as the ITER blanket FW. The Mock-ups fabricated with three kinds of interlayers such as Cr/Ti/Cu, Ti/Cr/Cu, Ti/Cu, which were different from the developed interlayer (Cr/Cu), total 6 Mock-ups were fabricated. Preliminary analysis were performed to decide the test conditions; they were tested with up to 2.5 MW/m2 of heat fluxes and 20 cycles for each Mock-up in a given heat flux. They were tested with JUDITH-1 at FZJ in Germany. During tests, all Mock-ups showed delamination or full detachment of Be tile and it can be concluded that the joints with these interlayers have a bad joining but it can be used as a good data for developing the Be/Cu joint with HIP.

  9. Data-Based Active Learning in the Principles of Macroeconomics Course: A Mock FOMC Meeting

    Science.gov (United States)

    Whiting, Cathleen

    2006-01-01

    The author presents an active-learning exercise for the introductory macroeconomics class in which students participate in a mock Federal Open Market Committee (FOMC) meeting. Preparation involves data gathering and writing both a research report and a policy recommendation. An FOMC meeting is simulated in which students give their policy…

  10. Surgical thromboendarterectomy for chronic thromboembolic pulmonary hypertension using circulatory arrest with selective antegrade cerebral perfusion

    NARCIS (Netherlands)

    Zeebregts, CJAM; Dossche, KM; Morshuis, WJ; Knaepen, PJ; Schepens, MAAM

    The use of circulatory arrest with selective antegrade cerebral perfusion is described in a 59-year-old man who underwent thrombendarterectomy for chronic thromboembolic pulmonary hypertension. The postoperative course was uneventful. The described surgical technique may prevent the patient from

  11. Generating log-normal mock catalog of galaxies in redshift space

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, Aniket; Makiya, Ryu; Saito, Shun; Komatsu, Eiichiro [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, 85741 Garching (Germany); Chiang, Chi-Ting [C.N. Yang Institute for Theoretical Physics, Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794 (United States); Jeong, Donghui, E-mail: aniket@mpa-garching.mpg.de, E-mail: makiya@mpa-garching.mpg.de, E-mail: chi-ting.chiang@stonybrook.edu, E-mail: djeong@psu.edu, E-mail: ssaito@mpa-garching.mpg.de, E-mail: komatsu@mpa-garching.mpg.de [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States)

    2017-10-01

    We present a public code to generate a mock galaxy catalog in redshift space assuming a log-normal probability density function (PDF) of galaxy and matter density fields. We draw galaxies by Poisson-sampling the log-normal field, and calculate the velocity field from the linearised continuity equation of matter fields, assuming zero vorticity. This procedure yields a PDF of the pairwise velocity fields that is qualitatively similar to that of N-body simulations. We check fidelity of the catalog, showing that the measured two-point correlation function and power spectrum in real space agree with the input precisely. We find that a linear bias relation in the power spectrum does not guarantee a linear bias relation in the density contrasts, leading to a cross-correlation coefficient of matter and galaxies deviating from unity on small scales. We also find that linearising the Jacobian of the real-to-redshift space mapping provides a poor model for the two-point statistics in redshift space. That is, non-linear redshift-space distortion is dominated by non-linearity in the Jacobian. The power spectrum in redshift space shows a damping on small scales that is qualitatively similar to that of the well-known Fingers-of-God (FoG) effect due to random velocities, except that the log-normal mock does not include random velocities. This damping is a consequence of non-linearity in the Jacobian, and thus attributing the damping of the power spectrum solely to FoG, as commonly done in the literature, is misleading.

  12. LOG-NORMAL DISTRIBUTION OF COSMIC VOIDS IN SIMULATIONS AND MOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Russell, E.; Pycke, J.-R., E-mail: er111@nyu.edu, E-mail: jrp15@nyu.edu [Division of Science and Mathematics, New York University Abu Dhabi, P.O. Box 129188, Abu Dhabi (United Arab Emirates)

    2017-01-20

    Following up on previous studies, we complete here a full analysis of the void size distributions of the Cosmic Void Catalog based on three different simulation and mock catalogs: dark matter (DM), haloes, and galaxies. Based on this analysis, we attempt to answer two questions: Is a three-parameter log-normal distribution a good candidate to satisfy the void size distributions obtained from different types of environments? Is there a direct relation between the shape parameters of the void size distribution and the environmental effects? In an attempt to answer these questions, we find here that all void size distributions of these data samples satisfy the three-parameter log-normal distribution whether the environment is dominated by DM, haloes, or galaxies. In addition, the shape parameters of the three-parameter log-normal void size distribution seem highly affected by environment, particularly existing substructures. Therefore, we show two quantitative relations given by linear equations between the skewness and the maximum tree depth, and between the variance of the void size distribution and the maximum tree depth, directly from the simulated data. In addition to this, we find that the percentage of voids with nonzero central density in the data sets has a critical importance. If the number of voids with nonzero central density reaches ≥3.84% in a simulation/mock sample, then a second population is observed in the void size distributions. This second population emerges as a second peak in the log-normal void size distribution at larger radius.

  13. Using Mock Trials to Teach Students Forensic Core Competencies in Marriage and Family Therapy

    Science.gov (United States)

    Miller, John K.; Linville, Deanna; Todahl, Jeff; Metcalfe, Joe

    2009-01-01

    This article provides a description of a university-based project that used mock trials to train both practicum-level marriage and family therapy and law students in forensic work, and a qualitative investigation of student experiences with the training. The content of the training focused on American Association for Marriage and Family Therapy…

  14. Circulatory Responses to Operative Stress in Females with Gestosis

    Directory of Open Access Journals (Sweden)

    I. V. Mikhno

    2007-01-01

    Full Text Available Objective: to study the specific features of hemodynamic responses in females with gestosis in the perioperative period; to evaluate the impact of intensive care on the basis of co-administration of dalargin, dexamethasone, pen-toxifylline, and reamberin.Materials and methods. A Diamant KM-AP-01 rheograph (Saint Petersburg was used to study hemodynamic parameters in 142 patients in whom surgical delivery was made under spinal anesthesia. A control group comprised 30 patients with uncomplicated pregnancy; Group 1 included 26 females with moderate gestosis; Group 2 consisted of 27 females with moderate gestosis who received the developed intensive care regimen; Group 3 comprised 29 females with severe gestosis; Group 4 included 30 females to whom the developed intensive care regimen was applied on the basis of the concurrent use of dalargin, dexamethasone, pentoxifylline, and reamberin.Results: A neurogenic mechanism prevails in females with moderate gestosis. The decreased baseline cardiac index is mostly due to a high postload. Surgical stress does not deteriorate postoperative circulatory parameters, which suggests that females with moderate gestosis have adequate capacities for self-regulation. As gestosis progresses to a severe degree, a role of humoral mechanisms increases in the maintenance of arteriolar spasm. Arteriolar spasm and hypokinetic hemodynamics are retained within 5 postoperative days, which is indicative of the inadequacy of self-regulation and compensatory mechanisms in overcoming two stressors: severe gestosis and surgical aggression.Conclusion: the intensive care regimen developed on the basis of combined use of dalargin, dexamethasone, pentoxifylline, and reamberin favors a more intensive (the promptest normalization of circulatory parameters after surgical delivery in females with moderate and severe gestosis. 

  15. Pre-brazed casting and hot radial pressing: A reliable process for the manufacturing of CFC and W monoblock mock-ups

    Energy Technology Data Exchange (ETDEWEB)

    Visca, Eliseo [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, Via E. Fermi, 45, IT-00044 Frascati, RM (Italy)], E-mail: visca@frascati.enea.it; Libera, S.; Mancini, A.; Mazzone, G.; Pizzuto, A. [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, Via E. Fermi, 45, IT-00044 Frascati, RM (Italy); Testani, C. [CSM S.p.A., IT-00128 Castel Romano, RM (Italy)

    2007-10-15

    ENEA is involved in the European International Thermonuclear Experimental Reactor (ITER) R and D activities and, in particular, for the manufacturing of high heat flux plasma-facing components (HHFC), such as the divertor targets, the baffles and the limiters. During last years, ENEA has manufactured actively cooled mock-ups by using different technologies, namely brazing, diffusion bonding and hot isostatic pressing (HIPping). A new manufacturing process has been set up and tested. It was successfully applied for the manufacturing of W armoured monoblock mock-ups. This technique is the HRP (hot radial pressing) based on performing a radial diffusion bonding between the cooling tube and the armour tile by pressurizing only internal tube and by keeping the joining zone in vacuum at the required bonding temperature. The heating is obtained by a standard air furnace. The HRP technique is now used for the manufacturing of CFC armoured monoblock components. For this purpose, some issues have to be faced, like the low CFC tensile strength, the pure copper interlayer between the heat sink and the armour necessary to mitigate the stress at the joint interface, and the low wettability of the pure copper on the CFC matrix. This paper reports the research path followed to manufacture a medium scale vertical target CFC and W armoured mock-up by HRP. A casting of a soft copper interlayer between the tube and the tile was obtained by a new technique: the pre-brazed casting (PBC, ENEA patent). Some preliminary mock-ups with three NB31 CFC tiles were successfully manufactured and tested to thermal fatigue using electron beam facilities. They all reached at least 1000 cycles at 20 MW/m{sup 2} without suffering any damage. The manufactured medium scale vertical target mock-up is now under testing at the FE2000 (France) facility. These activities were performed in the frame of ITER-EFDA contracts.

  16. Transfusion-associated circulatory overload in adult, medical emergency patients with perspectives on early warning practice

    DEFF Research Database (Denmark)

    Gosmann, Fanny; Nørgaard, Astrid; Rasmussen, Maj-Britt

    2018-01-01

    of transfusion-associated dyspnoea. Vital signs and changes in dyspnoea and blood pressure were registered within the frame of the Early Warning Score, and one case was documented as being transfusion-related in the medical record. No cases were reported to the haemovigilance system. DISCUSSION: The incidence...... to the haemovigilance system. The clinical implications are discussed within the frame of the Early Warning Score. METHODS: We conducted a retrospective audit of electronic hospital medical records of patients receiving blood transfusion in a single medical emergency unit. Patients were admitted during a 6-month period...... and data on symptoms and vital signs were extracted from the records. RESULTS: Of 4,353 consecutively admitted patients, 156 patients were transfused with a total of 411 blood components. The audit identified five cases of transfusion-associated circulatory overload (incidence 3.2%) and four cases...

  17. Dendrimer Brain Uptake and Targeted Therapy for Brain Injury in a Large Animal Model of Hypothermic Circulatory Arrest

    Science.gov (United States)

    2015-01-01

    Treatment of brain injury following circulatory arrest is a challenging health issue with no viable therapeutic options. Based on studies in a clinically relevant large animal (canine) model of hypothermic circulatory arrest (HCA)-induced brain injury, neuroinflammation and excitotoxicity have been identified as key players in mediating the brain injury after HCA. Therapy with large doses of valproic acid (VPA) showed some neuroprotection but was associated with adverse side effects. For the first time in a large animal model, we explored whether systemically administered polyamidoamine (PAMAM) dendrimers could be effective in reaching target cells in the brain and deliver therapeutics. We showed that, upon systemic administration, hydroxyl-terminated PAMAM dendrimers are taken up in the brain of injured animals and selectively localize in the injured neurons and microglia in the brain. The biodistribution in other major organs was similar to that seen in small animal models. We studied systemic dendrimer–drug combination therapy with two clinically approved drugs, N-acetyl cysteine (NAC) (attenuating neuroinflammation) and valproic acid (attenuating excitotoxicity), building on positive outcomes in a rabbit model of perinatal brain injury. We prepared and characterized dendrimer-NAC (D-NAC) and dendrimer-VPA (D-VPA) conjugates in multigram quantities. A glutathione-sensitive linker to enable for fast intracellular release. In preliminary efficacy studies, combination therapy with D-NAC and D-VPA showed promise in this large animal model, producing 24 h neurological deficit score improvements comparable to high dose combination therapy with VPA and NAC, or free VPA, but at one-tenth the dose, while significantly reducing the adverse side effects. Since adverse side effects of drugs are exaggerated in HCA, the reduced side effects with dendrimer conjugates and suggestions of neuroprotection offer promise for these nanoscale drug delivery systems. PMID:24499315

  18. Dendrimer brain uptake and targeted therapy for brain injury in a large animal model of hypothermic circulatory arrest.

    Science.gov (United States)

    Mishra, Manoj K; Beaty, Claude A; Lesniak, Wojciech G; Kambhampati, Siva P; Zhang, Fan; Wilson, Mary A; Blue, Mary E; Troncoso, Juan C; Kannan, Sujatha; Johnston, Michael V; Baumgartner, William A; Kannan, Rangaramanujam M

    2014-03-25

    Treatment of brain injury following circulatory arrest is a challenging health issue with no viable therapeutic options. Based on studies in a clinically relevant large animal (canine) model of hypothermic circulatory arrest (HCA)-induced brain injury, neuroinflammation and excitotoxicity have been identified as key players in mediating the brain injury after HCA. Therapy with large doses of valproic acid (VPA) showed some neuroprotection but was associated with adverse side effects. For the first time in a large animal model, we explored whether systemically administered polyamidoamine (PAMAM) dendrimers could be effective in reaching target cells in the brain and deliver therapeutics. We showed that, upon systemic administration, hydroxyl-terminated PAMAM dendrimers are taken up in the brain of injured animals and selectively localize in the injured neurons and microglia in the brain. The biodistribution in other major organs was similar to that seen in small animal models. We studied systemic dendrimer-drug combination therapy with two clinically approved drugs, N-acetyl cysteine (NAC) (attenuating neuroinflammation) and valproic acid (attenuating excitotoxicity), building on positive outcomes in a rabbit model of perinatal brain injury. We prepared and characterized dendrimer-NAC (D-NAC) and dendrimer-VPA (D-VPA) conjugates in multigram quantities. A glutathione-sensitive linker to enable for fast intracellular release. In preliminary efficacy studies, combination therapy with D-NAC and D-VPA showed promise in this large animal model, producing 24 h neurological deficit score improvements comparable to high dose combination therapy with VPA and NAC, or free VPA, but at one-tenth the dose, while significantly reducing the adverse side effects. Since adverse side effects of drugs are exaggerated in HCA, the reduced side effects with dendrimer conjugates and suggestions of neuroprotection offer promise for these nanoscale drug delivery systems.

  19. A SCALE-UP Mock-Up: Comparison of Student Learning Gains in High- and Low-Tech Active-Learning Environments.

    Science.gov (United States)

    Soneral, Paula A G; Wyse, Sara A

    2017-01-01

    Student-centered learning environments with upside-down pedagogies (SCALE-UP) are widely implemented at institutions across the country, and learning gains from these classrooms have been well documented. This study investigates the specific design feature(s) of the SCALE-UP classroom most conducive to teaching and learning. Using pilot survey data from instructors and students to prioritize the most salient SCALE-UP classroom features, we created a low-tech "Mock-up" version of this classroom and tested the impact of these features on student learning, attitudes, and satisfaction using a quasi--experimental setup. The same instructor taught two sections of an introductory biology course in the SCALE-UP and Mock-up rooms. Although students in both sections were equivalent in terms of gender, grade point average, incoming ACT, and drop/fail/withdraw rate, the Mock-up classroom enrolled significantly more freshmen. Controlling for class standing, multiple regression modeling revealed no significant differences in exam, in-class, preclass, and Introduction to Molecular and Cellular Biology Concept Inventory scores between the SCALE-UP and Mock-up classrooms. Thematic analysis of student comments highlighted that collaboration and whiteboards enhanced the learning experience, but technology was not important. Student satisfaction and attitudes were comparable. These results suggest that the benefits of a SCALE-UP experience can be achieved at lower cost without technology features. © 2017 P. A. G. Soneral and S. A. Wyse. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  20. A pacemaker powered by an implantable biofuel cell operating under conditions mimicking the human blood circulatory system--battery not included.

    Science.gov (United States)

    Southcott, Mark; MacVittie, Kevin; Halámek, Jan; Halámková, Lenka; Jemison, William D; Lobel, Robert; Katz, Evgeny

    2013-05-07

    Biocatalytic electrodes made of buckypaper were modified with PQQ-dependent glucose dehydrogenase on the anode and with laccase on the cathode and were assembled in a flow biofuel cell filled with serum solution mimicking the human blood circulatory system. The biofuel cell generated an open circuitry voltage, Voc, of ca. 470 mV and a short circuitry current, Isc, of ca. 5 mA (a current density of 0.83 mA cm(-2)). The power generated by the implantable biofuel cell was used to activate a pacemaker connected to the cell via a charge pump and a DC-DC converter interface circuit to adjust the voltage produced by the biofuel cell to the value required by the pacemaker. The voltage-current dependencies were analyzed for the biofuel cell connected to an Ohmic load and to the electronic loads composed of the interface circuit, or the power converter, and the pacemaker to study their operation. The correct pacemaker operation was confirmed using a medical device - an implantable loop recorder. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions using a single biofuel cell. This first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.

  1. The physiology of dinosaurs: circulatory and respiratory function in the largest animals ever to walk the earth.

    Science.gov (United States)

    Pierson, David J

    2009-07-01

    The cardiopulmonary physiology of dinosaurs-and especially of the long-necked sauropods, which grew much larger than any land animals before or since-should be inherently fascinating to anyone involved in respiratory care. What would the blood pressure be in an animal 12 m (40 ft) tall? How could airway resistance and dead space be overcome while breathing through a trachea 9 m (30 ft) long? The last decade has seen a dramatic increase in evidence bearing on these questions. Insight has come not only from new fossil discoveries but also from comparative studies of living species, clarification of evolutionary relationships, new evaluation techniques, computer modeling, and discoveries about the earth's ancient atmosphere. Pumping a vertical column of blood 8 m (26 ft) above the heart would probably require an arterial blood pressure > 600 mm Hg, and the implications of this for cardiac size and function have led to the proposal of several alternative cardiopulmonary designs. Diverse lines of evidence suggest that the giant sauropods were probably warm-blooded and metabolically active when young, but slowed their metabolism as they approached adult size, which diminished the load on the circulatory system. Circulatory considerations leave little doubt that the dinosaurs had 4-chambered hearts. Birds evolved from dinosaurs, and the avian-type air-sac respiratory system, which is more efficient than its mammalian counterpart, may hold the answer to the breathing problems posed by the sauropods' very long necks. Geochemical and other data indicate that, at the time the dinosaurs first appeared, the atmospheric oxygen concentration was only about half of what it is today, and development of the avian-type respiratory system may have been key in the dinosaurs' evolutionary success, enabling them to out-compete the mammals and dominate the land for 150 million years.

  2. TANK 18 AND 19-F TIER 1A EQUIPMENT FILL MOCK UP TEST SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2011-11-04

    The United States Department of Energy (US DOE) has determined that Tanks 18-F and 19-F have met the F-Tank Farm (FTF) General Closure Plan Requirements and are ready to be permanently closed. The high-level waste (HLW) tanks have been isolated from FTF facilities. To complete operational closure they will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) discouraging future intrusion, and (4) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. Bulk waste removal and heel removal equipment remain in Tanks 18-F and 19-F. This equipment includes the Advance Design Mixer Pump (ADMP), transfer pumps, transfer jets, standard slurry mixer pumps, equipment-support masts, sampling masts, dip tube assemblies and robotic crawlers. The present Tank 18 and 19-F closure strategy is to grout the equipment in place and eliminate vertical pathways by filling voids in the equipment to vertical fast pathways and water infiltration. The mock-up tests described in this report were intended to address placement issues identified for grouting the equipment that will be left in Tank 18-F and Tank 19-F. The Tank 18-F and 19-F closure strategy document states that one of the Performance Assessment (PA) requirements for a closed tank is that equipment remaining in the tank be filled to the extent practical and that vertical flow paths 1 inch and larger be grouted. The specific objectives of the Tier 1A equipment grout mock-up testing include: (1) Identifying the most limiting equipment configurations with respect to internal void space filling; (2) Specifying and constructing initial test geometries and forms that represent scaled boundary conditions; (3) Identifying a target grout rheology for evaluation in the scaled mock-up configurations; (4) Scaling-up production of a grout mix with the target rheology

  3. An Innovative Approach to Pharmacy Law Education Utilizing a Mock Board of Pharmacy Meeting

    Directory of Open Access Journals (Sweden)

    D. Todd Bess

    2016-03-01

    Full Text Available A thorough understanding of pharmacy law by students is important in the molding of future pharmacy practitioners, but a standardized template for the best way to educate students in this area has not been created. A mock Board of Pharmacy meeting was designed and incorporated into the Pharmacy Law course at the University of Tennessee College of Pharmacy. Students acted as Board of Pharmacy members and utilized technology to decide outcomes of cases and requests addressed in a typical 2 day Tennessee Board of Pharmacy meeting. The actual responses to those cases, as well as similar cases and requests addressed over a 5 year period, were revealed to students after they made motions on mock scenarios. The mock Board of Pharmacy meeting engages the students in a way that lectures alone often fail to achieve with some initial evidence of successful student learning. Utilizing this teaching format as a law education tool challenges the status quo of pharmacy education and may serve as an impetus and catalyst for future innovations. Conflict of Interest We declare no conflicts of interest or financial interests that the authors or members of their immediate families have in any product or service discussed in the manuscript, including grants (pending or received, employment, gifts, stock holdings or options, honoraria, consultancies, expert testimony, patents, and royalties. Dr. Wang’s time was partly supported by the National Institute on Aging of the National Institutes of Health under Award Number R01AG040146 and R01AG049696. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.   Type: Idea Paper

  4. Bling My Research! A Mock Grant Panel Activity Illustrating the Importance of Basic Research

    Science.gov (United States)

    Leander, Celeste A.; Whitton, Jeannette

    2010-01-01

    First-year university students have misconceptions about the source and dynamics of publicly funded research money. We designed an activity in which students take part in a mock grant panel. The results indicated a strong tendency toward student funding of applied medical research at the expense of basic research. Exposure to a few examples of…

  5. Outcome of pancreas transplantation from donation after circulatory death compared to donation after brain death

    NARCIS (Netherlands)

    van Loo, Ellen S.; Krikke, Christina; Hofker, Hendrik S.; Berger, Stefan P.; Leuvenink, Henri G. D.; Pol, Robert A.

    Introduction: To overcome the gap of organ shortage grafts from donation after circulatory death (DCD) can be used. This review evaluates the outcomes after DCD pancreas donation compared to donation after brain death (DBD). Materials and methods: A literature search was performed using Medline,

  6. Relevances between cerebral circulatory disorder and symptom in idiopathic normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Takeuchi, Totaro; Shimizu, Tsuneo; Watanabe, Kazuo

    2010-01-01

    The subjects were shunt-effective idiopathic normal pressure hydrocephalus (iNPH) 40 patients. Before and one year after surgery, measurements of the cerebral circulatory dynamics (the cerebral blood flow pattern by region of interest (ROI) setting using 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT)), and an evaluation of symptoms (gait disturbance: G, dementia: D, urinary incontinence: U) by grading scale (JNPHGS-R). Preoperative cerebral circulation and symptoms: As for the each symptoms and blood flow patterns, the seventies of G (p=0.017) in whole cortex non-reduction group (thalamus-basal ganglia reduction group) and D (p=0.021) in whole cortex reduction group were obviously high compared with other symptoms particularly. Circulation and symptoms one year after surgery: As the circulatory dynamics at different improvement sites and each symptoms, it was obviously mild for G (p=0.003) in the group with an increased only thalamus-basal ganglia blood flow and increased both whole cortex and thalamus-basal ganglia blood flow and tend to mild for D (p=0.091) in the group with an increased only whole cortex blood flow and increased both whole cortex and thalamus-basal ganglia blood flow compared with other symptoms. (author)

  7. Receptor-mediated oral delivery of a bioencapsulated green fluorescent protein expressed in transgenic chloroplasts into the mouse circulatory system.

    Science.gov (United States)

    Limaye, Arati; Koya, Vijay; Samsam, Mohtashem; Daniell, Henry

    2006-05-01

    Oral delivery of biopharmaceutical proteins expressed in plant cells should reduce their cost of production, purification, processing, cold storage, transportation, and delivery. However, poor intestinal absorption of intact proteins is a major challenge. To overcome this limitation, we investigate here the concept of receptor-mediated oral delivery of chloroplast-expressed foreign proteins. Therefore, the transmucosal carrier cholera toxin B-subunit and green fluorescent protein (CTB-GFP), separated by a furin cleavage site, was expressed via the tobacco chloroplast genome. Polymerase chain reaction (PCR) and Southern blot analyses confirmed site-specific transgene integration and homoplasmy. Immunoblot analysis and ELISA confirmed expression of monomeric and pentameric forms of CTB-GFP, up to 21.3% of total soluble proteins. An in vitro furin cleavage assay confirmed integrity of the engineered furin cleavage site, and a GM1 binding assay confirmed the functionality of CTB-GFP pentamers. Following oral administration of CTB-GFP expressing leaf material to mice, GFP was observed in the mice intestinal mucosa, liver, and spleen in fluorescence and immunohistochemical studies, while CTB remained in the intestinal cell. This report of receptor-mediated oral delivery of a foreign protein into the circulatory system opens the door for low-cost production and delivery of human therapeutic proteins.

  8. Determination of death after circulatory arrest by intensive care physicians: A survey of current practice in the Netherlands.

    Science.gov (United States)

    Wind, Jentina; van Mook, Walther N K A; Dhanani, Sonny; van Heurn, Ernest W L

    2016-02-01

    Determination of death is an essential part of donation after circulatory death (DCD). We studied the current practices of determination of death after circulatory arrest by intensive care physicians in the Netherlands, the availability of guidelines, and the occurrence of the phenomenon of autoresuscitation. The Determination of Cardiac Death Practices in Intensive Care Survey was sent to all intensive care physicians. Fifty-five percent of 568 Dutch intensive care physicians responded. Most respondents learned death determination from clinical practice. The most commonly used tests for death determination were flat arterial line tracing, flat electrocardiogram (standard 3-lead electrocardiogram), and fixed and dilated pupils. Rarely used tests were absence pulse by echo Doppler, absent blood pressure by noninvasive monitoring, and unresponsiveness to painful stimulus. No diagnostic test or procedure was uniformly performed, but 80% of respondents perceived a need for standardization of death determination. Autoresuscitation was witnessed by 37%, after withdrawal of treatment or after unsuccessful resuscitation. Extensive variability in the practice of determining death after circulatory arrest exists, and a need for guidelines and standardization, especially if organ donation follows death, is reported. Autoresuscitation is reported; this observation requires attention in further prospective observational studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Full scale mock-up tests for rod bundle thermal-hydraulics in Japan

    International Nuclear Information System (INIS)

    Sugawara, S.

    1995-01-01

    This poster describes tests aimed at development and validation of principal design methodology of rod bundle thermal-hydraulics correlations. The works are based on domestic data base using the full-scale mock-up test facilities. The scope of the tests comprises DNB heat flux, transient DNB heat flux, post DNB heat transfer, pressure drop and void distribution. The works have been performed under collaboration among electric facilities, NPP vendors, universities, governmental corporations. 1 tab., 14 figs

  10. NDE of explosion welded copper stainless steel first wall mock-up

    International Nuclear Information System (INIS)

    Taehtinen, S.; Kauppinen, P.; Jeskanen, H.; Lahdenperae, K.; Ehrnsten, U.

    1997-04-01

    The study showed that reflection type C-mode scanning acoustic microscope (C-SAM) and internal ultrasonic inspection (IRIS) equipment can be applied for ultrasonic examination of copper stainless steel compound structures of ITER first wall mock-ups. Explosive welding can be applied to manufacture fully bonded copper stainless steel compound plates. However, explosives can be applied only for mechanical tightening of stainless steel cooling tubes within copper plate. If metallurgical bonding between stainless steel tubes and copper plate is required Hot Isostatic Pressing (HIP) method can be applied. (orig.)

  11. Circulatory shear flow alters the viability and proliferation of circulating colon cancer cells

    Science.gov (United States)

    Fan, Rong; Emery, Travis; Zhang, Yongguo; Xia, Yuxuan; Sun, Jun; Wan, Jiandi

    2016-06-01

    During cancer metastasis, circulating tumor cells constantly experience hemodynamic shear stress in the circulation. Cellular responses to shear stress including cell viability and proliferation thus play critical roles in cancer metastasis. Here, we developed a microfluidic approach to establish a circulatory microenvironment and studied circulating human colon cancer HCT116 cells in response to a variety of magnitude of shear stress and circulating time. Our results showed that cell viability decreased with the increase of circulating time, but increased with the magnitude of wall shear stress. Proliferation of cells survived from circulation could be maintained when physiologically relevant wall shear stresses were applied. High wall shear stress (60.5 dyne/cm2), however, led to decreased cell proliferation at long circulating time (1 h). We further showed that the expression levels of β-catenin and c-myc, proliferation regulators, were significantly enhanced by increasing wall shear stress. The presented study provides a new insight to the roles of circulatory shear stress in cellular responses of circulating tumor cells in a physiologically relevant model, and thus will be of interest for the study of cancer cell mechanosensing and cancer metastasis.

  12. Evaluation of exercise-respiratory system modifications and integration schemes for physiological systems

    Science.gov (United States)

    Gallagher, R. R.

    1974-01-01

    Exercise subroutine modifications are implemented in an exercise-respiratory system model yielding improvement of system response to exercise forcings. A more physiologically desirable respiratory ventilation rate in addition to an improved regulation of arterial gas tensions and cerebral blood flow is observed. A respiratory frequency expression is proposed which would be appropriate as an interfacing element of the respiratory-pulsatile cardiovascular system. Presentation of a circulatory-respiratory system integration scheme along with its computer program listing is given. The integrated system responds to exercise stimulation for both nonstressed and stressed physiological states. Other integration possibilities are discussed with respect to the respiratory, pulsatile cardiovascular, thermoregulatory, and the long-term circulatory systems.

  13. Efficient construction of mock catalogs for baryon acoustic oscillation surveys

    International Nuclear Information System (INIS)

    Sunayama, Tomomi; Padmanabhan, Nikhil; Heitmann, Katrin; Habib, Salman; Rangel, Esteban

    2016-01-01

    Precision measurements of the large scale structure of the Universe require large numbers of high fidelity mock catalogs to accurately assess, and account for, the presence of systematic effects. We introduce and test a scheme for generating mock catalogs rapidly using suitably derated N-body simulations. Our aim is to reproduce the large scale structure and the gross properties of dark matter halos with high accuracy, while sacrificing the details of the halo's internal structure. By adjusting global and local time-steps in an N-body code, we demonstrate that we recover halo masses to better than 0.5% and the power spectrum to better than 1% both in real and redshift space for k =1 h Mpc −1 , while requiring a factor of 4 less CPU time. We also calibrate the redshift spacing of outputs required to generate simulated light cones. We find that outputs separated by Δ z =0.05 allow us to interpolate particle positions and velocities to reproduce the real and redshift space power spectra to better than 1% (out to k =1 h Mpc −1 ). We apply these ideas to generate a suite of simulations spanning a range of cosmologies, motivated by the Baryon Oscillation Spectroscopic Survey (BOSS) but broadly applicable to future large scale structure surveys including eBOSS and DESI. As an initial demonstration of the utility of such simulations, we calibrate the shift in the baryonic acoustic oscillation peak position as a function of galaxy bias with higher precision than has been possible so far. This paper also serves to document the simulations, which we make publicly available.

  14. Blanket Manufacturing Technologies : Thermomechanical Tests on HCLL Blanket Mocks Up

    International Nuclear Information System (INIS)

    Laffont, G.; Cachon, L.; Taraud, P.; Challet, F.; Rampal, G.; Salavy, J.F.

    2006-01-01

    In the Helium Cooled Lithium Lead (HCLL) Blanket concept, the lithium lead plays the double role of breeder and multiplier material, and the helium is used as coolant. The HCCL Blanket Module are made of steel boxes reinforced by stiffening plates. These stiffening plates form cells in which the breeder is slowly flowing. The power deposited in the breeder material is recovered by the breeder cooling units constituted by 5 parallel cooling plates. All the structures such as first wall, stiffening and cooling plates are cooled by helium. Due to the complex geometry of these parts and the high level of pressure and temperature loading, thermo-mechanical phenomena expected in the '' HCLL blanket concept '' have motivated the present study. The aim of this study, carried out in the frame of EFDA Work program, is to validate the manufacturing technologies of HCLL blanket module by testing small scale mock-up under breeder blanket representative operating conditions.The first step of this experimental program is the design and manufacturing of a relevant test section in the DIADEMO facility, which was recently upgraded with an He cooling loop (pressure of 80 bar, maximum temperature of 500 o C,flow rate of 30 g/s) taking the opportunity of synergies with the gas-cooled fission reactor R-and-D program. The second step will deal with the thermo-mechanical tests. This paper focuses on the program made to support the cooling plate mock up tests which will be carried out on the DIADEMO facility (CEA) by thermo-mechanical calculations in order to define the relevant test conditions and the experimental parameters to be monitored. (author)

  15. Report on the second Mock LISA data challenge

    International Nuclear Information System (INIS)

    Babak, Stanislav; Porter, Edward K; Baker, John G; Benacquista, Matthew J; Cornish, Neil J; Littenberg, Tyson B; Crowder, Jeff; Cutler, Curt; Vallisneri, Michele; Larson, Shane L; Vecchio, Alberto; Auger, Gerard; Barack, Leor; Blaut, Arkadiusz; Bloomer, Ed; Clark, James; Brown, Duncan A; Fairhurst, Stephen; Christensen, Nelson; Gair, Jonathan R

    2008-01-01

    The Mock LISA data challenges are a program to demonstrate LISA data-analysis capabilities and to encourage their development. Each round of challenges consists of several data sets containing simulated instrument noise and gravitational waves from sources of undisclosed parameters. Participants are asked to analyze the data sets and report the maximum information about the source parameters. The challenges are being released in rounds of increasing complexity and realism: here we present the results of Challenge 2, issued in Jan 2007, which successfully demonstrated the recovery of signals from nonspinning supermassive-black-hole binaries with optimal SNRs between ∼10 and 2000, from ∼20 000 overlapping galactic white-dwarf binaries (among a realistically distributed population of 26 million), and from the extreme-mass-ratio inspirals of compact objects into central galactic black holes with optimal SNRs ∼100

  16. Construction of PREMUX and preliminary experimental results, as preparation for the HCPB breeder unit mock-up testing

    Energy Technology Data Exchange (ETDEWEB)

    Hernández, F., E-mail: francisco.hernandez@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany); Kolb, M. [Karlsruhe Institute of Technology (KIT), Institute for Applied Materials (IAM-WPT) (Germany); Annabattula, R. [Indian Institute of Technology Madras (IITM), Department of Mechanical Engineering (India); Weth, A. von der [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology (INR) (Germany)

    2014-10-15

    Highlights: • PREMUX has been constructed as preparation for a future out-of-pile thermo-mechanical qualification of a HCPB breeder unit mock-up. • The rationale and constructive details of PREMUX are reported in this paper. • PREMUX serves as a test rig for the new heater system developed for the HCPB-BU mock-up. • PREMUX will be used as benchmark for the thermal and thermo-mechanical models developed in ANSYS for the pebble beds of the HCPB-BU. • Preliminary results show the functionality of PREMUX and the good agreement of the measured temperatures with the thermal model developed in ANSYS. - Abstract: One of the European blanket designs for ITER is the Helium Cooled Pebble Bed (HCPB) blanket. The core of the HCPB-TBM consists of so-called breeder units (BUs), which encloses beryllium as neutron multiplier and lithium orthosilicate (Li{sub 4}SiO{sub 4}) as tritium breeder in form of pebble beds. After the design phase of the HCPB-BU, a non-nuclear thermal and thermo-mechanical qualification program for this device is running at the Karlsruhe Institute of Technology. Before the complex full scale BU testing, a pre-test mock-up experiment (PREMUX) has been constructed, which consists of a slice of the BU containing the Li{sub 4}SiO{sub 4} pebble bed. PREMUX is going to be operated under highly ITER-relevant conditions and has the following goals: (1) as a testing rig of new heater concept based on a matrix of wire heaters, (2) as benchmark for the existing finite element method (FEM) codes used for the thermo-mechanical assessment of the Li{sub 4}SiO{sub 4} pebble bed, and (3) in situ measurement of thermal conductivity of the Li{sub 4}SiO{sub 4} pebble bed during the tests. This paper describes the construction of PREMUX, its rationale and the experimental campaign planned with the device. Preliminary results testing the algorithm used for the temperature reconstruction of the pebble bed are reported and compared qualitatively with first analyses

  17. Fabrication of a 1/6-scale mock-up and manifolds for the Korea first wall in the ITER

    International Nuclear Information System (INIS)

    Yoon, Jae Sung; Kim, Suk Kwon; Lee, Eo Hwak; Lee, Dong Won

    2012-01-01

    Korea has developed and participated in the Test Blanket Module (TBM) program of the International Thermo-nuclear Experimental Reactor (ITER). The first wall (FW) of the TBM is an important component that faces the plasma directly and therefore it is subjected to high heat and neutron loads. To fabricate the TBM FW, the Hot Isostatic Pressing (HIP) bonding method has been investigated. In the present study, the manufacturing method of the TBM FW is introduced through the fabrication and testing of a 1/6-scale mockup. To distribute fluid uniformly in the mock-up, a manifold was designed and fabricated using the ANSYS-CFX analysis. After the mock-up was fabricated and its fluid distribution tests performed, we compared the results of tests with the simulated results

  18. Circulatory shock in horses / Choque circulatório em equinos

    Directory of Open Access Journals (Sweden)

    José Monteira da Silva Filho

    2010-04-01

    Full Text Available Circulatory shock can be defined as an acute circulatory failure with an inadequate tissue delivery of oxygen and nutritive substrates to the tissues, resulting in generalised cellular hypoxia. Shock can be classified as cardiogenic, obstructive, hypovolaemic, or distributive. The pathophysiologic consequences of inadequate tissue perfusion are directly related to cell ischemia, inadequate O2 delivery, and the production of proinflammatory mediators. If abnormalities of tissue perfusion are allowed to persist, the function of vital organs will be impaired. The subsequent reperfusion will exacerbate organ dysfunction and, in severe cases, may culminate in multiple organ dysfunction syndrome. Early recognition of equine that are shocked and immediate provision of effective circulatory support is therefore essential. In all cases the objective is to restore oxygen delivery to the tissues while correcting the underlying cause. Delays in making the diagnosis and initiating treatment, as well as suboptimal resuscitation, contribute to the development of peripheral vascular failure and irreversible defects in oxygen use which can culminate in vital organ dysfunction.Choque circulatório pode ser definido como uma falha circulatória aguda com liberação inadequada de oxigênio e nutrientes aos tecidos, resultando em hipóxia celular. O choque pode ser classificado como cardiogênico, obstrutivo, hipovolêmico ou distributivo. As consequências fisiopatológicas da perfusão tecidual inadequada estão diretamente relacionadas à isquemia celular, liberação inadequada de O2 e produção de potentes mediadores inflamatórios. Caso as anormalidades de perfusão tecidual se perpetuem, a função de vários órgãos se torna inadequada. A consequente reperfusão poderá exacerbar a disfunção orgânica e, nos casos graves, culminar na síndrome da disfunção orgânica múltipla. O reconhecimento precoce de equinos em choque circulatório e o

  19. ASTP crewmen in Soyuz orbital module mock-up during training session at JSC

    Science.gov (United States)

    1975-01-01

    An interior view of the Soyuz orbital module mock-up in bldg 35 during Apollo Soyuz Test Project (ASTP) joint crew training at JSC. The ASTP crewmen are Astronaut Vance D. Brand (on left), command module pilot of the American ASTP prime crew; and Cosmonaut Valeriy N. Kubasov, engineer on the Soviet ASTP first (prime) crew. The training session simulated activities on the second day in Earth orbit.

  20. Mock Data Challenge for the MPD/NICA Experiment on the HybriLIT Cluster

    Science.gov (United States)

    Gertsenberger, Konstantin; Rogachevsky, Oleg

    2018-02-01

    Simulation of data processing before receiving first experimental data is an important issue in high-energy physics experiments. This article presents the current Event Data Model and the Mock Data Challenge for the MPD experiment at the NICA accelerator complex which uses ongoing simulation studies to exercise in a stress-testing the distributed computing infrastructure and experiment software in the full production environment from simulated data through the physical analysis.

  1. Pancreas transplantation with grafts from donors deceased after circulatory death (DCD) : 5 years single center experience

    NARCIS (Netherlands)

    Kopp, Wouter H; Lam, Hwai-Ding; Schaapherder, Alexander F M; Huurman, Volkert A L; van der Boog, Paul; de Koning, Eelco; de Fijter, Johan W; Baranski, Andrzej; Braat, Andries E

    2017-01-01

    INTRODUCTION: Donation after circulatory death (DCD) pancreas transplantation has been shown to be an additional way to deal with donor organ shortages. The results of 5-year DCD pancreas transplantation are presented. METHODS: A retrospective, single center analysis (2011 - 2015) was performed to

  2. Annual report on experimental operations and maintenance of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system in 2004 fiscal year (Contract research)

    International Nuclear Information System (INIS)

    Hayashi, Koji; Ohashi, Hirofumi; Morisaki, Norihiro; Kato, Michio; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Inaba, Yoshitomo; Takada, Shoji; Inagaki, Yoshiyuki

    2006-03-01

    This is annual report on the experimental test operations and maintenances of the mock-up test facility with a full-scale reaction tube for the HTTR hydrogen production system in 2004 fiscal year. The improvement work of catalyst dust filter in combustion system was performed in May 2004, and the performance was confirmed. The sixth experimental test operation was performed from June to July 2004. Periodic inspections on boiler equipment and high-pressure gas production facilities were performed from end of July to September 2004. The seventh experimental test operation was performed from October to December 2004 for chemical reaction shutdown test. From the results, a behavior of the helium-gas cooling system, consists of steam generator and radiator, during chemical reaction shutdown was confirmed. This report is summarized with the outline and the results of the test, maintenance works and inspections, and operation records in mentioned above. (author)

  3. The Mock Trial: A Dynamic Exercise for Thinking Critically about Management Theories, Topics, and Practices

    Science.gov (United States)

    Farmer, Kevin; Meisel, Steven I.; Seltzer, Joe; Kane, Kathleen

    2013-01-01

    The Mock Trial is an experiential exercise adapted from a law school process that encourages students to think critically about theories, topics, and the practice of management in an innovative classroom experience. Playing the role of attorneys and witnesses, learners ask questions and challenge assumptions by playing roles in a trial with…

  4. Structural analysis, design and evaluation of mock-up platform, monorail, and tank plate cut-out

    International Nuclear Information System (INIS)

    Hundal, T.S.

    1995-01-01

    Platform - Structural analyses were performed for design seismic, live and dead load combinations for the freestanding platform over the partial DST mock-up section. The platform is to be used for Robotic ultrasonic inspection of the tank wall. It is a free standing structure anchored to floor slab with Hilti Kwik bolts

  5. Fast Neutron Transport in the Biological Shielding Model and Other Regions of the VVER-1000 Mock-Up on the LR-0 Research Reactor

    Directory of Open Access Journals (Sweden)

    Košťál Michal

    2016-01-01

    Full Text Available A set of benchmark experiments was carried out in the full scale VVER-1000 mock-up on the reactor LR-0 in order to validate neutron transport calculation methodologies and to perform the optimization of the shape and locations of neutron flux operation monitors channels inside the shielding of the new VVER-1000 type reactors. Compared with previous experiments on the VVER-1000 mock-up on the reactor LR-0, the fast neutron spectra were measured in the extended neutron energy interval (0.1–10 MeV and new calculations were carried out with the MCNPX code using various nuclear data libraries (ENDF/B VII.0, JEFF 3.1, JENDL 3.3, JENDL 4, ROSFOND 2009, and CENDL 3.1. Measurements and calculations were carried out at different points in the mock-up. The calculation and experimental data are compared.

  6. Residual stress measurement inside a dissimilar metal weld mock-up of the pressurizer safety and relief nozzle

    International Nuclear Information System (INIS)

    Campos, Wagner R.C.; Rabello, Emerson G.; Silva, Luiz L.; Mansur, Tanius R.; Martins, Ketsia S.

    2015-01-01

    Residual stresses are present in materials or structural component in the absence of external loads or changes in temperatures. The most common causes of residual stresses being present are the manufacturing or assembling processes. All manufacturing processes, such as casting, welding, machining, molding, heat treatment, among others, introduces residual stresses into the manufactured object. The residual stresses effects could be beneficial or detrimental, depending on its distribution related to the component or structure, its load service and if it is compressive or tensile. In this work, the residual strains and stresses inside a mock-up that simulates the safety and relief nozzle of Angra 1 Nuclear Power Plant pressurizer were studied. The current paper presents a blind hole-drilling method residual stress measurements both at the inner surface of dissimilar metal welds of dissimilar metal weld nozzle mock-up. (author)

  7. Residual stress measurement inside a dissimilar metal weld mock-up of the pressurizer safety and relief nozzle

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Wagner R.C.; Rabello, Emerson G.; Silva, Luiz L.; Mansur, Tanius R., E-mail: wrcc@cdtn.br, E-mail: egr@cdtn.br, E-mail: silvall@cdtn.br, E-mail: tanius@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte (Brazil). Servico de Integridade Estrutural; Martins, Ketsia S., E-mail: ketshinoda@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Nelo Horizonte (Brazil). Departamento de Engenharia Metalurgica

    2015-07-01

    Residual stresses are present in materials or structural component in the absence of external loads or changes in temperatures. The most common causes of residual stresses being present are the manufacturing or assembling processes. All manufacturing processes, such as casting, welding, machining, molding, heat treatment, among others, introduces residual stresses into the manufactured object. The residual stresses effects could be beneficial or detrimental, depending on its distribution related to the component or structure, its load service and if it is compressive or tensile. In this work, the residual strains and stresses inside a mock-up that simulates the safety and relief nozzle of Angra 1 Nuclear Power Plant pressurizer were studied. The current paper presents a blind hole-drilling method residual stress measurements both at the inner surface of dissimilar metal welds of dissimilar metal weld nozzle mock-up. (author)

  8. Antithrombin III is associated with acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support.

    Science.gov (United States)

    Hoefer, Judith; Ulmer, Hanno; Kilo, Juliane; Margreiter, Raimund; Grimm, Michael; Mair, Peter; Ruttmann, Elfriede

    2017-06-01

    There are few data on the role of liver dysfunction in patients with end-stage heart failure supported by mechanical circulatory support. The aim of our study was to investigate predictors for acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support. A consecutive 164 patients with heart failure with New York Heart Association class IV undergoing mechanical circulatory support were investigated for acute liver failure using the King's College criteria. Clinical characteristics of heart failure together with hemodynamic and laboratory values were analyzed by logistic regression. A total of 45 patients (27.4%) with heart failure developed subsequent acute liver failure with a hospital mortality of 88.9%. Duration of heart failure, cause, cardiopulmonary resuscitation, use of vasopressors, central venous pressure, pulmonary capillary wedge pressure, pulmonary pulsatility index, cardiac index, and transaminases were not significantly associated with acute liver failure. Repeated decompensation, atrial fibrillation (P failure in univariate analysis only. In multivariable analysis, decreased antithrombin III was the strongest single measurement indicating acute liver failure (relative risk per %, 0.84; 95% confidence interval, 0.77-0.93; P = .001) and remained an independent predictor when adjustment for the Model for End-Stage Liver Disease score was performed (relative risk per %, 0.89; 95% confidence interval, 0.80-0.99; P = .031). Antithrombin III less than 59.5% was identified as a cutoff value to predict acute liver failure with a corresponding sensitivity of 81% and specificity of 87%. In addition to the Model for End-Stage Liver Disease score, decreased antithrombin III activity tends to be superior in predicting acute liver failure compared with traditionally thought predictors. Antithrombin III measurement may help to identify patients more precisely who are developing acute liver failure during mechanical

  9. Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

    Science.gov (United States)

    Kawahito, Koji

    2013-09-01

    Although non-destructive and continuous monitoring is indispensable for long-term circulatory support with rotary blood pumps, a practical monitoring system has not yet been developed. The objective of this study was to investigate the possibility of detecting pump failure caused by thrombus formation through the monitoring of vibration signals. The data acquisition equipment included vibration pickups, a charge amplifier, vibration analysis systems, and exclusive hardware. A pivot-bearing centrifugal pump with a mock circuit was investigated for vibration analysis. To simulate the four common areas of thrombus formation, we used a piece of silicon attached to each of the following four locations: the total area of the bottom of the impeller, an eccentric shape on the bottom of the impeller, a circular shape around the shaft top, and an eccentric shape on the top of the impeller. Vibration signals were picked up, and the power spectrum density analysis was performed at pump rotational speeds of 2100, 2400, and 3000 rpm. In this study, pump failure could be detected, and the types of imitation thrombi could be determined. We conclude that vibration detection with a computerized analysis system is a potentially valuable diagnostic tool for long-term circulatory support with rotary blood pumps.

  10. Mock-up-CZ: dismantling of the experiment - Geotechnical results

    International Nuclear Information System (INIS)

    Svoboda, J.; Vasicek, R.

    2010-01-01

    Document available in extended abstract form only. The issue of the disposal of radioactive waste is one of the most pressing challenges of our age, for which, in most countries, the deep repository concept is generally considered to be the most suitable final solution. In order to make such a repository both safe and reliable, intensive research is underway worldwide. The construction of physical models is one approach to the study of the engineered barriers for deep geological repositories; one such experiment, Mock-Up-CZ, has been performed at the Centre of Experimental Geotechnics, CTU in Prague. The Mock-Up-CZ experiment simulated the vertical placement of a container with radioactive waste, an approach that is in line with the Swedish KBS-3 system. The physical model consisted of a barrier made up of bentonite blocks, powdered bentonite backfill, a heater and hydration and monitoring systems. The whole experiment was enclosed in a cylindrical box, whose construction was able to withstand high pressure due to bentonite swelling. A number of sensors (monitoring changes in temperature, pressure and moisture) were placed inside the bentonite barrier. The basic material used in the experiment consisted of a mixture of Czech bentonite from the Rokle deposit (85%), quartz sand (10%) and graphite (5%). The first phase of the experiment commenced on 7 May 2002, during which the heater was switched on, with no water input. After 6 months the second phase commenced in which water was introduced through the hydration system. This phase ended on 2nd January 2006 when the heater was switched off. After allowing time for cooling, the dismantling phase commenced (30 January 2006). After a further one and a half months (17 March 2006) the dismantling of the experimental vessel was completed. Post-decommissioning analysis continued until the end of 2007. Dismantling and post-decommissioning analysis were carried out according to a very detailed plan which included not only

  11. Functional stability of cerebral circulatory system

    Science.gov (United States)

    Moskalenko, Y. Y.

    1980-01-01

    The functional stability of the cerebral circulation system seems to be based on the active mechanisms and on those stemming from specific of the biophysical structure of the system under study. This latter parameter has some relevant criteria for its quantitative estimation. The data obtained suggest that the essential part of the mechanism for active responses of cerebral vessels which maintains the functional stability of this portion of the vascular system, consists of a neurogenic component involving central nervous structures localized, for instance, in the medulla oblongata.

  12. Report of the remote-handled transuranic waste mock retrieval demonstration

    International Nuclear Information System (INIS)

    1987-05-01

    This report documents the results of the mock, onsite retrieval demonstration that was conducted on May 19 and 20, 1987, for representatives of the New Mexico Environmental Evaluation Group (EEG). Demonstration of the retrievability of remote-handled transuranic (RH TRU) waste is part of a milestone included in the Agreement for Consultation and Cooperation between the state of New Mexico and the United States Department of Energy. Retrieval equipment design documents and a retrievability demonstration plan for RH TRU waste were previously transmitted to the EEG. This report documents the results of the demonstration by evaluating the demonstration against the acceptance criteria that were established in the Demonstration Plan. 1 fig., 2 tabs

  13. Spectral line intensity irreversibility in circulatory plasma magnetization processes

    Science.gov (United States)

    Qu, Z. Q.; Dun, G. T.

    2012-01-01

    Spectral line intensity variation is found to be irreversible in circulatory plasma magnetization process by experiments described in this paper, i.e., the curves illustrating spectral line photon fluxes irradiated from a light source immerged in a magnetic field by increasing the magnetic induction cannot be reproduced by decreasing the magnetic induction within the errors. There are two plasma magnetization patterns found. One shows that the intensities are greater at the same magnetic inductions during the magnetic induction decreasing process after the increasing, and the other gives the opposite effect. This reveals that the magneto-induced excitation and de-excitation process is irreversible like ferromagnetic magnetization. But the two irreversible processes are very different in many aspects stated in the text.

  14. Colloids Versus Albumin in Large Volume Paracentesis to Prevent Circulatory Dysfunction: Evidence-based Case Report.

    Science.gov (United States)

    Widjaja, Felix F; Khairan, Paramita; Kamelia, Telly; Hasan, Irsan

    2016-04-01

    Large volume paracentesis may cause paracentesis induced circulatory dysfunction (PICD). Albumin is recommended to prevent this abnormality. Meanwhile, the price of albumin is too expensive and there should be another alternative that may prevent PICD. This report aimed to compare albumin to colloids in preventing PICD. Search strategy was done using PubMed, Scopus, Proquest, dan Academic Health Complete from EBSCO with keywords of "ascites", "albumin", "colloid", "dextran", "hydroxyethyl starch", "gelatin", and "paracentesis induced circulatory dysfunction". Articles was limited to randomized clinical trial and meta-analysis with clinical question of "In hepatic cirrhotic patient undergone large volume paracentesis, whether colloids were similar to albumin to prevent PICD". We found one meta-analysis and four randomized clinical trials (RCT). A meta analysis showed that albumin was still superior of which odds ratio 0.34 (0.23-0.51). Three RCTs showed the same results and one RCT showed albumin was not superior than colloids. We conclude that colloids could not constitute albumin to prevent PICD, but colloids still have a role in patient who undergone paracentesis less than five liters.

  15. OUTCOMES OF LIVER TRANSPLANTATION USING DONATIONS AFTER CIRCULATORY DEATH : A SINGLE-CENTER EXPERIENCE

    OpenAIRE

    MEURISSE, Nicolas; VANDEN BUSSCHE, S; JOCHMANS, I; FRANCOIS, J; DESSCHANS, B; LALEMAN, W; VAN DER MERWE, S; VAN STEENBERGEN, W; CASSIMAN, D; VERSLYPE, C; AERTS, R; NEVENS, F; PIRENNE, J; MONBALIU, D

    2012-01-01

    Introduction Orthotopic liver transplantation (OLT) (LTx) using donation after circulatory death (DCD) donors is increasingly performed, but still considered to risk of poorer outcomes compared with standard donations after brain death (DBD)-OLT. Therefore we reviewed our results of DCD-OLT. Patients and Methods Between 2003 and 2010, we performed 30 DCD-OLT (6% of all OLT). We retrospectively reviewed medical records of donors and recipients after DCD versus DBD-OLT to analyze bil...

  16. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    Science.gov (United States)

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  17. In-pile testing of ITER first wall mock-ups at relevant thermal loading conditions in the LVR-15 nuclear research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kysela, Jan [Research Centre Rez, Hlavni 130, 250 68 Husinec-Rez (Czech Republic); Entler, Slavomir, E-mail: slavomir.entler@cvrez.cz [Research Centre Rez, Hlavni 130, 250 68 Husinec-Rez (Czech Republic); Vsolak, Rudolf; Klabik, Tomas [Research Centre Rez, Hlavni 130, 250 68 Husinec-Rez (Czech Republic); Zlamal, Ondrej [CEZ, Duhova 2/1444, 140 53 Praha 4 (Czech Republic); Bellin, Boris; Zacchia, Francesco [Fusion for Energy, Josep Pla, 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2015-10-15

    Highlights: • Irradiated thermal fatigue testing of the ITER primary first wall mock-ups. • Cyclic heat flux of 0.5 MW/m{sup 2} in the neutron field of the nuclear reactor core. • 17,040 thermal cycles. • Radiation damage in the range of 0.41–1.17 dpa depending on the material. - Abstract: The TW3 in-pile rig enabled the thermal fatigue testing of ITER primary first wall mock-ups in the core of the nuclear reactor. This experiment investigated the neutron irradiation influence on the design performance under high heat flux testing. A thermal flux of 0.5 MW/m{sup 2} in the neutron field of the core of the LVR-15 nuclear reactor was applied. Within the scope of the tests with simultaneous neutron irradiation, the TW3 rig reached a record of 17,040 thermal cycles with the radiation damage in the range of 0.41–1.17 dpa depending on the material. Even after a high number of thermal cycles, while being irradiated by neutrons, no damage of the tested mock-ups was visually observed. Further testing and analysis will follow in the Forschungszentrum Juelich.

  18. Plasma coatings of nitrogen polymers on metal prostheses of the circulatory system; Recubrimientos por plasma de polimeros nitrogenados sobre protesis metalicas del sistema circulatorio

    Energy Technology Data Exchange (ETDEWEB)

    Gomez J, L. M.

    2016-07-01

    This work has a study about the synthesis of poly aniline, poly allylamine and poly pyrrole doped with iodine onto metallic surfaces similar to stents for the circulatory system. Ar, water and hydrogen peroxide plasmas were used for eroding, conditioning and synthesizing polymers that potentially reduce some rejection reactions when stents are implanted in the human body. Stents are small metallic meshes that applied inside collapsed arteries or veins enlarge the diameter and restore the blood flow, however the metallic surfaces usually cause rejection reactions that obstruct the veins again. To give solutions to this problem, in this work is studied the synthesis of biocompatible polymer coatings on the stents that resist the blood flow forming a biocompatible interface between metal and blood. The metallic substrates were eroded and chemically prepared with Ar, H{sub 2}O and/or H{sub 2}O{sub 2} glow discharges on which the polymers were synthesized by plasma. The coatings were morphologically characterized by optical, scanning electron and atomic force microscopy, the chemical structure was studied by infrared and photoelectron X-ray spectroscopy. The hydrophilicity was studied measuring the advance static contact angle and the adhesion was evaluated indirectly with scanning electron microscopy after two months submerged in buffered phosphate solutions. The results indicate that the polymers grew following the superficial morphology; that the conditioning with Ar ions erode the substrates and that the conditioning with H{sub 2}O or H{sub 2}O{sub 2} erodes and activates the surface generating oxygen bridges which help in the polymer-metal adhesion. The chemical structure of the polymeric coatings contain crosslinked structures that correspond to links between monomers with the participation of all atoms, states that suggest monomer fragmentation and oxidation and states that indicate oxygen bridges in the polymers. The coatings had contact angles close to 90

  19. Manufacturing of small-scale mock-ups and of a semi-prototype of the ITER Normal Heat Flux First Wall

    International Nuclear Information System (INIS)

    Banetta, S.; Zacchia, F.; Lorenzetto, P.; Bobin-Vastra, I.; Boireau, B.; Cottin, A.; Mitteau, R.; Eaton, R.; Raffray, R.

    2014-01-01

    This paper describes the manufacturing development and fabrication of reduced scale ITER First Wall (FW) mock-ups of the Normal Heat Flux (NHF) design, including a “semi-prototype” with a dimension of 305 mm × 660 mm, corresponding to about 1/6 of a full-scale panel. The activity was carried out in the framework of the pre-qualification of the European Domestic Agency (EU-DA or F4E) for the supply of the European share of the ITER First Wall. The hardware consists of three Upgraded (2 MW/m 2 ) Normal Heat Flux (U-NHF) small-scale mock-ups, bearing 3 beryllium tiles each, and of one Semi-Prototype, representing six full-scale fingers and bearing a total of 84 beryllium tiles. The manufacturing process makes extensive use of Hot Isostatic Pressing, which was developed over more than a decade during ITER Engineering Design Activity phase. The main manufacturing steps for the semi-prototype are described, with special reference to the lessons learned and the implications impacting the future fabrication of the full-scale prototype and the series which consists of 218 panels plus spares. In addition, a “tile-size” mock-up was manufactured in order to assess the performance of larger tiles. The use of larger tiles would be highly beneficial since it would allow a significant reduction of the panel assembly time

  20. A proposal of ITER vacuum vessel fabrication specification and results of the full-scale partial mock-up test

    International Nuclear Information System (INIS)

    Nakahira, M.; Takeda, N.; Kakudate, S.; Onozuka, M.

    2008-01-01

    The structure and fabrication methods of the ITER vacuum vessel (VV) have been investigated and defined by the ITER International Team (IT). However, some of the current technical specifications are difficult to be achieved from the manufacturing point of view. To solve such an issue, this paper proposes an alternative specification of the VV to the IT's design. A series of the fabrication and assembly procedures for the mock-up are presented, together with candidates of welding configurations. Finally, the paper summarizes the results of mock-up fabrication, such as non-destructive examination of weld lines, obtained welding deformation and issues revealed from the fabrication experience. Based on the results, it is suggested that several issues such as clarification of conditions of repair welding, demonstration of welding distortion control and detectability/localization of internal defects should be solved before manufacturing the ITER VV

  1. The first mock data challenge for LISA Pathfinder

    Energy Technology Data Exchange (ETDEWEB)

    Monsky, A; Hewitson, M; Wanner, G; Nofrarias, M; Diepholz, I; Danzmann, K [Albert-Einstein-Institut, Max-Planck-Institut fuer Gravitationsphysik und Universitaet Hannover, 30167 Hannover (Germany); Ferraioli, L; Hueller, M; Cavalleri, A; Ciani, G; Dolesi, R [Dipartimento di Fisica, Universita di Trento and INFN, Gruppo Collegato di Trento, 38050 Povo, Trento (Italy); Grynagier, A [Institut fuer Flugmechanik und Flugregelung, 70569 Stuttgart (Germany); Armano, M [European Space Agency, ESAC, Villanueva de la Canada, 28692 Madrid (Spain); Benedetti, M [Dipartimento di Ingegneria dei Materiali e Tecnologie Industriali, Universita di Trento and INFN, Gruppo Collegato di Trento, Mesiano, Trento (Italy); Bogenstahl, J [Department of Physics and Astronomy, University of Glasgow, Glasgow (United Kingdom); Bortoluzzi, D; Bosetti, P; Cristofolini, I [Dipartimento di Ingegneria Meccanica e Strutturale, Universita di Trento and INFN, Gruppo Collegato di Trento, Mesiano, Trento (Italy); Brandt, N [Astrium GmbH, 88039 Friedrichshafen (Germany); Cruise, M, E-mail: anneke.monsky@aei.mpg.d [Department of Physics and Astronomy, University of Birmingham, Birmingham (United Kingdom)

    2009-05-07

    The data analysis of the LISA Technology Package (LTP) will comprise a series of discrete experiments, each focusing on a particular noise measurement or characterization of the instrument in various operating modes. Each of these experiments must be analysed and planned in advance of the mission because the results of a given experiment will have an impact on those that follow. As such, a series of mock data challenges (MDCs) will be developed and carried out with the aim of preparing the analysis tools and optimizing the various planned analyses. The first of these MDCs (MDC1) is a simplified treatment of the dynamics along the axis joining the two test masses onboard LISA Pathfinder. The validation of the dynamical model by predicting the spectra of the interferometer output data is shown, a prediction for the data analysis is calculated and, finally, several simulated interferometer data sets are analysed and calibrated to equivalent out-of-loop test mass acceleration.

  2. Coating and Characterization of Mock and Explosive Materials

    Directory of Open Access Journals (Sweden)

    Emily M. Hunt

    2012-01-01

    Full Text Available This project develops a method of manufacturing plastic-bonded explosives by using use precision control of agglomeration and coating of energetic powders. The energetic material coating process entails suspending either wet or dry energetic powders in a stream of inert gas and contacting the energetic powder with atomized droplets of a lacquer composed of binder and organic solvent. By using a high-velocity air stream to pneumatically convey the energetic powders and droplets of lacquer, the energetic powders are efficiently wetted while agglomerate drying begins almost immediately. The result is an energetic powder uniformly coated with binder, that is, a PBX, with a high bulk density suitable for pressing. Experiments have been conducted using mock explosive materials to examine coating effectiveness and density. Energetic materials are now being coated and will be tested both mechanically and thermally. This allows for a comprehensive comparison of the morphology and reactivity of the newly coated materials to previously manufactured materials.

  3. Squashed Toric Sigma Models and Mock Modular Forms

    Science.gov (United States)

    Gupta, Rajesh Kumar; Murthy, Sameer

    2018-05-01

    We study a class of two-dimensional N}=(2,2)} sigma models called squashed toric sigma models, using their Gauged Linear Sigma Models (GLSM) description. These models are obtained by gauging the global {U(1)} symmetries of toric GLSMs and introducing a set of corresponding compensator superfields. The geometry of the resulting vacuum manifold is a deformation of the corresponding toric manifold in which the torus fibration maintains a constant size in the interior of the manifold, thus producing a neck-like region. We compute the elliptic genus of these models, using localization, in the case when the unsquashed vacuum manifolds obey the Calabi-Yau condition. The elliptic genera have a non-holomorphic dependence on the modular parameter {τ} coming from the continuum produced by the neck. In the simplest case corresponding to squashed {C / Z_{2 the elliptic genus is a mixed mock Jacobi form which coincides with the elliptic genus of the {N=(2,2)} {SL(2,R) / U(1)} cigar coset.

  4. The role of perfusion lung scanning and diffusion capacity for early diagnosis of micro circulatory disturbances in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Petrova, D.; Shoshlov, P.; Hadjikostova, H.

    2002-01-01

    The development of chronic obstructive pulmonary disease (COPD) and the frequent inflammatory exacerbations with development of respiratory failure lead to changes in the micro circulatory and an increased risk of lung thrombotic and thromboembolic complication. The aim of the study was to establish the possibility of the perfusion lung scanning and diffusion capacity for early diagnosis of pulmonary micro circulatory disturbances in COPD with mild and moderate respiratory failure. 59 COPD patients were investigated. The data presented significant segmental disorders. Only in 5 (8.47%) of them the perfusion lung scintigrams were normal. In 23 of the patients, single-breath diffusing capacity (DICO) and its two components: membranous component (Dm) and capillary blood component (Vc) were determined. DICO was lower especially Vc the mean sign of micro circulatory disorders. A relationship between the degree of hypoxaemia and the changes found in the perfusion scintigraphy was found. Changes in the pulmonary lung scanning and in the diffusion capacity in COPD with mild respiratory failure seem to be an early diagnostic test. The early anticoagulant and desaggregant prevention may decrease the risk of thrombotic complications in the development of the disease. (authors)

  5. Sensitivity Analysis of Median Lifetime on Radiation Risks Estimates for Cancer and Circulatory Disease amongst Never-Smokers

    Science.gov (United States)

    Chappell, Lori J.; Cucinotta, Francis A.

    2011-01-01

    Radiation risks are estimated in a competing risk formalism where age or time after exposure estimates of increased risks for cancer and circulatory diseases are folded with a probability to survive to a given age. The survival function, also called the life-table, changes with calendar year, gender, smoking status and other demographic variables. An outstanding problem in risk estimation is the method of risk transfer between exposed populations and a second population where risks are to be estimated. Approaches used to transfer risks are based on: 1) Multiplicative risk transfer models -proportional to background disease rates. 2) Additive risk transfer model -risks independent of background rates. In addition, a Mixture model is often considered where the multiplicative and additive transfer assumptions are given weighted contributions. We studied the influence of the survival probability on the risk of exposure induced cancer and circulatory disease morbidity and mortality in the Multiplicative transfer model and the Mixture model. Risks for never-smokers (NS) compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for NS, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity, esophagus, colon, a portion of the solid cancer remainder, and leukemia. Greater improvements in risk estimates for NS s are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

  6. Heat transfer characteristics evaluation of heat exchangers of mock-up test facility with full-scale reaction tube for HTTR hydrogen production system (Contract research)

    International Nuclear Information System (INIS)

    Shimizu, Akira; Ohashi, Hirofumi; Kato, Michio; Hayashi, Koji; Aita, Hideki; Nishihara, Tetsuo; Inaba, Yoshitomo; Takada, Shoji; Morisaki, Norihiro; Sakaki, Akihiro; Maeda, Yukimasa; Sato, Hiroyuki; Inagaki, Yoshiyuki; Hanawa, Hiromi; Fujisaki, Katsuo; Yonekawa, Hideo

    2005-06-01

    Connection of hydrogen production system by steam reforming of methane to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) has been surveyed until now. Mock-up test facility of this steam reforming system with full-scale reaction tube was constructed in FY 2001 and hydrogen of 120 Nm 3 /h was successfully produced in overall performance test. Totally 7 times operational tests were performed from March 2002 to December 2004. A lot of operational test data on heat exchanges were obtained in these tests. In this report specifications and structures of steam reformer, steam superheater, steam generator, condenser, helium gas cooler, feed gas heater and feed gas superheater were described. Heat transfer correlation equations for inside and outside tube were chosen from references. Spreadsheet programs were newly made to evaluate heat transfer characteristics from measured test data such as inlet and outlet temperature pressure and flow-rate. Overall heat-transfer coefficients obtained from the experimental data were compared and evaluated with the calculated values with heat transfer correlation equation. As a result, actual measurement values of all heat exchangers gave close agreement with the calculated values with correlation equations. Thermal efficiencies of the heat exchangers were adequate as they were well accorded with design value. (author)

  7. Original Research. Statistical Study Regarding Differences Between the Wax-Up, Mock-Up, and Final Restoration

    Directory of Open Access Journals (Sweden)

    Jánosi Kinga

    2017-03-01

    Full Text Available The aesthetic rehabilitation of patients remains a challenge for practicians. To facilitate the clinicians’ and technicians’ task, several innovative methods were developed, like the diagnostic wax-up and mock-up. The width-to-length ratio of the maxillary frontal teeth can be used to evaluate dentofacial aesthetics. Our study presents the variations between the teeth size measured on casts obtained during the prosthodontic treatment.

  8. Police reports of mock suspect interrogations: A test of accuracy and perception.

    Science.gov (United States)

    Kassin, Saul M; Kukucka, Jeff; Lawson, Victoria Z; DeCarlo, John

    2017-06-01

    A 2-phased experiment assessed the accuracy and completeness of police reports on mock interrogations and their effects on people's perceptions. In Phase 1, 16 experienced officers investigated a mock crime scene, interrogated 2 innocent suspects-1 described by the experimenter as more suspicious than the other-and filed an incident report. All 32 sessions were covertly recorded; the recordings were later used to assess the reports. In Phase 2, 96 lay participants were presented with a brief summary of the case and then either read 1 police report, read 1 verbatim interrogation transcript, or listened to an audiotape of a session. Results showed that (a) Police and suspects diverged in their perceptions of the interrogations; (b) Police committed frequent errors of omission in their reports, understating their use of confrontation, maximization, leniency, and false evidence; and (c) Phase 2 participants who read a police report, compared to those who read a verbatim transcript, perceived the process as less pressure-filled and were more likely to misjudge suspects as guilty. These findings are limited by the brevity and low-stakes nature of the task and by the fact that no significant effects were obtained for our suspicion manipulation, suggesting a need for more research. Limitations notwithstanding, this study adds to a growing empirical literature indicating the need for a requirement that all suspect interrogations be electronically recorded. To provide a more objective and accurate account of what transpired, this study also suggests the benefit of producing verbatim transcripts. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. A proposal of ITER vacuum vessel fabrication specification and results of the full-scale partial mock-up test

    Energy Technology Data Exchange (ETDEWEB)

    Nakahira, M. [Japan Atomic Energy Agency, Mukouyama 801-1, Naka-machi, Naka-gun, Ibaraki 311-0193 (Japan)], E-mail: nakahira.masataka@jaea.go.jp; Takeda, N.; Kakudate, S. [Japan Atomic Energy Agency, Mukouyama 801-1, Naka-machi, Naka-gun, Ibaraki 311-0193 (Japan); Onozuka, M. [Mitsubishi Nuclear Energy Systems, Inc., 1700K Street NW, Suite 440, Washington, DC 20006 (United States)

    2008-12-15

    The structure and fabrication methods of the ITER vacuum vessel (VV) have been investigated and defined by the ITER International Team (IT). However, some of the current technical specifications are difficult to be achieved from the manufacturing point of view. To solve such an issue, this paper proposes an alternative specification of the VV to the IT's design. A series of the fabrication and assembly procedures for the mock-up are presented, together with candidates of welding configurations. Finally, the paper summarizes the results of mock-up fabrication, such as non-destructive examination of weld lines, obtained welding deformation and issues revealed from the fabrication experience. Based on the results, it is suggested that several issues such as clarification of conditions of repair welding, demonstration of welding distortion control and detectability/localization of internal defects should be solved before manufacturing the ITER VV.

  10. Visualization test using piping group mock up specimen for evaluation of wastage phenomena in steam generator for FBR

    International Nuclear Information System (INIS)

    Kato, Keisuke; Yoshida, Atsuro; Arae, Kunihiko; Narabayashi, Tadashi; Ohshima, Hiroyuki; Kurihara, Akikazu

    2012-01-01

    There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code. (author)

  11. [Mechanical circulatory support saves lives -- three years' experience of the newly established assist device program at Semmelweis University, Budapest, Hungary].

    Science.gov (United States)

    Fazekas, Levente; Sax, Balázs; Hartyánszky, István; Pólos, Miklós; Horkay, Ferenc; Varga, Tamás; Rácz, Kristóf; Németh, Endre; Székely, Andrea; Paulovich, Erzsébet; Heltai, Krisztina; Zima, Endre; Szabolcs, Zoltán; Merkely, Béla

    2015-03-29

    Since the celebration of the 20th anniversary of the first heart transplantation in Hungary in 2012 the emerging need for modern heart failure management via mechanical circulatory support has evolved. In May 2012 the opening of a new heart failure and transplant unit with 9 beds together with the procurement of necessary devices at Semmelweis University accomplished this need. The aim of the authors was to report their initial experience obtained in this new cardiac assist device program. Since May, 2012, mechanical circulatory support system was applied in 89 cases in 72 patients. Indication for support were end stage heart failure refractory to medical treatment and acute left or right heart failure. Treatment was initiated for acute graft failure after heart transplantation in 27 cases, for end stage heart failure in 24 cases, for acute myocardial infarction in 21 cases, for acute postcardiotomy heart failure in 14 cases, for severe respiratory insufficiency in 2 cases and for drug intoxication in one case. Among the 30 survivor of the whole program 13 patients were successfully transplanted. The available devices can cover all modalities of current bridge therapy from short term support through medium support to heart transplantation or long term support and destination therapy. These conditions made possible the successful start of a new cardiac assist device program.

  12. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    Science.gov (United States)

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  13. CT screening of vertebrarterial circulatory disorder

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Shigeru; Toyoda, Keiko; Moriyama, Hiroshi [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-09-01

    The frequency of MR angiography (MRA) used to diagnose vertebrobasiliar insufficiency appears high. Findings of abnormality by MRA show cases with maldescription of hemivertebral artery. In such cases, it is unclear whether these are due to anaplasia of the vertebral artery or to the existence of morbid constriction, thus requiring confirmation by a vertebral arteriography (VAG). We observe the vascular morphology of vertebral artery by Computed tomography (CT) scanning for screening circulatory disorders. In photography and CT scan reading, the region was severally photographed between foramen magnum and aortic arch by plain CT and contrast CT at a slice of 5 mm. The constrictive region of the vertebral artery was estimated by comparing plain and contrast CT. Subjects were 34 clinical cases of vascular maldescription in the vertebrobasilar artery, nearly no blood vessel description, or blood vessel winding or inclination. We determined the constrictive morbid state of the vertebral or subclavian artery and cervical vertebra deformity. In findings of maldescription by MRA, it was suggested that discrimination is feasible to a certain degree, whether the vertebral artery has a morbid constrictive region or due to anaplasia. Our results suggest that screening by CT scanning may be more efficient than that by MRA. (author)

  14. CT screening of vertebrarterial circulatory disorder

    International Nuclear Information System (INIS)

    Yoshida, Shigeru; Toyoda, Keiko; Moriyama, Hiroshi

    2001-01-01

    The frequency of MR angiography (MRA) used to diagnose vertebrobasiliar insufficiency appears high. Findings of abnormality by MRA show cases with maldescription of hemivertebral artery. In such cases, it is unclear whether these are due to anaplasia of the vertebral artery or to the existence of morbid constriction, thus requiring confirmation by a vertebral arteriography (VAG). We observe the vascular morphology of vertebral artery by Computed tomography (CT) scanning for screening circulatory disorders. In photography and CT scan reading, the region was severally photographed between foramen magnum and aortic arch by plain CT and contrast CT at a slice of 5 mm. The constrictive region of the vertebral artery was estimated by comparing plain and contrast CT. Subjects were 34 clinical cases of vascular maldescription in the vertebrobasilar artery, nearly no blood vessel description, or blood vessel winding or inclination. We determined the constrictive morbid state of the vertebral or subclavian artery and cervical vertebra deformity. In findings of maldescription by MRA, it was suggested that discrimination is feasible to a certain degree, whether the vertebral artery has a morbid constrictive region or due to anaplasia. Our results suggest that screening by CT scanning may be more efficient than that by MRA. (author)

  15. Progression of Mortality due to Diseases of the Circulatory System and Human Development Index in Rio de Janeiro Municipalities

    Directory of Open Access Journals (Sweden)

    Gabriel Porto Soares

    Full Text Available Abstract Background: Diseases of the circulatory system (DCS are the major cause of death in Brazil and worldwide. Objective: To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI from 1970 onwards. Methods: Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD, cerebrovascular diseases (CBVD and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. Results: In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. Conclusion: The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions.

  16. Progression of Mortality due to Diseases of the Circulatory System and Human Development Index in Rio de Janeiro Municipalities

    Science.gov (United States)

    Soares, Gabriel Porto; Klein, Carlos Henrique; Silva, Nelson Albuquerque de Souza e; de Oliveira, Glaucia Maria Moraes

    2016-01-01

    Background Diseases of the circulatory system (DCS) are the major cause of death in Brazil and worldwide. Objective To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI) from 1970 onwards. Methods Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD), cerebrovascular diseases (CBVD) and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. Results In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. Conclusion The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions. PMID:27849263

  17. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  18. Occlusive ascending aorta and arch atheroma treated with deep hypothermic circulatory arrest and thromboendarterectomy.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2013-12-01

    We describe an uncommon presentation of severely advanced aortic atherosclerosis in a 48-year old man with a history of hypertension and heavy smoking. Initial presentation with upper limb ischaemia led to the diagnosis of an aortic arch atheroma occluding 90% of the aortic lumen, managed with deep hypothermic circulatory arrest and aortic thromboendarterectomy. To our knowledge, this is the first reported case of atherosclerotic plaque resulting in aortic occlusion and requiring emergent operative intervention.

  19. Oxidative Stress and Methods for Its Correction in Patients with Acute Coronary Circulatory Disorders During Perioperative Direct Myocardial Revascularization

    Directory of Open Access Journals (Sweden)

    M. V. Chumakov

    2008-01-01

    Full Text Available Objective: to study the effect of the antioxidant and cardioprotector mexicor on oxidative stress in patients with acute coronary circulatory disorders (ACCD during perioperative direct myocardial revascularization. Subjects and methods. The study included 33 patients with ACCD who had undergone coronary bypass surgery. Two groups (a study group and a control one were formed. Prior to surgery, all the patients received the maximum doses of antianginal and antihypertensive drugs. The study group patients additionally took mexicor. All patients were operated on under extracorporeal circulation and moderate hypothermia. Lipid peroxidation (LPO indices were estimated via measurements of the serum levels of dienic conjugates, malonic dialdehyde, and the degree of serum lipid oxidability. The serum antioxidative system (AOS was judged from the concentration of а-tocopherol and cerulo-plasmin. The oxidative stress coefficient K, an integral index, was calculated to evaluate LPO-AOS imbalance. Results. High oxidative stress was found to be detectable in patients with ACCD. Mexicor lowers oxidative stress, diminishes LPO-AOS imbalance, improves oxygen balance and cardiac contractility, and reduces the number of life-threatening cardiac arrhythmias. Conclusion. Mexicor diminishes oxidative stress in patients with ACCD in the perioperative period of coronary bypass surgery. Mexicor-induced stabilization of LPO positively affects better oxygen balance and cardiac contractility, thus reducing the number of perioperative complications. Key words: oxidative stress, dienic conjugates, malonic dialdehyde, а-tocopherol, ceruloplasmin, coronary bypass, acute coronary circulatory disorder, hemodynamics.

  20. Containment Evaluation under Severe Accidents (CESA): synthesis of the predictive calculations and analysis of the first experimental results obtained on the Civaux mock-up

    International Nuclear Information System (INIS)

    Granger, L.; Rieg, C.Y.; Touret, J.P.; Fleury, F.; Nahas, G.; Danisch, R.; Brusa, L.; Millard, A.; Laborderie, C.; Ulm, F.; Contri, P.; Schimmelpfennig, K.; Barre, F.; Firnhaber, M.; Gauvain, J; Coulon, N.; Dutton, L.M.C.; Tuson, A.

    2001-01-01

    In 1996, EDF decided to build a containment model at the scale 1:3, the MAEVA mock-up, in order to check and study the behaviour of a pre-stressed concrete containment vessel without a liner in terms of mechanical strength and leaktightness, for loadings corresponding to its design and beyond design conditions. In parallel with the construction and testing of the mock-up, a cost-shared R and D action supported by the European Union, the CESA project, is dealing with quantification of leak rates through concrete cracks and porosity, predictive calculations of the behaviour of the mock-up and analysis of the experimental results. In this paper, we propose a synthesis of the main theoretical and experimental results, obtained after 2.5 years. It should however be noted that, due to some unexpected delays in the experimental programme, quite natural with such a huge and unique experimental set-up, only the design-basis accident sequences, already performed, have been reported in this paper. The first results are nevertheless very interesting, both from a scientific and nuclear utility point of view

  1. Analysis of free and forced excitation tests of 394 KN isolated structure mock-up

    International Nuclear Information System (INIS)

    Serino, G.; Martelli, A.; Bonacina, G.

    1993-01-01

    At the 1991 ASME-PVP Conference, some first experimental results obtained from static and dynamic tests on high damping steel laminated rubber bearings (Martelli et al., 1991) and from free and forced excitation tests on a 394 kN isolated structure mock-up were presented (Forni et al., 1991). In this paper, the most significant test data are reorganized and discussed in order to assess the suitability of single bearing test results to predict the dynamic response of an isolated structure. Three mathematical models of the single isolator having different levels of approximation are proposed, and their capability to estimate the experimental response of the mock-up is evaluated. It is shown that a non-linear hysteretic model, defined by three rubber parameters only, allows a very good complete simulation of the dynamic behavior of the isolated structure in both free and forced vibration tests. A simpler equivalent linear viscous model permits a good prediction of the peak absolute acceleration and relative displacement values if bearing stiffness and damping parameters are properly selected, and can be used in a response spectrum analysis, but reproduces less exactly the experimental behavior. An equivalent linear hysteretic model represents more correctly the actual rubber damping behavior, but gives results very similar to those obtained through the equivalent linear viscous model because of the practically mono-frequencial response of the isolated structure

  2. Effects of Particulate Matter and Its Chemical Constituents on Elderly Hospital Admissions Due to Circulatory and Respiratory Diseases

    Directory of Open Access Journals (Sweden)

    Tatiane Morais Ferreira

    2016-09-01

    Full Text Available Various fractions of particulate matter have been associated with increased mortality and morbidity. The purpose of our study is to analyze the associations between concentrations of PM2.5, PM2.5–10, PM10 and their chemical constituents (soluble ions with hospital admissions due to circulatory and respiratory diseases among the elderly in a medium-sized city in Brazil. A time series study was conducted using Poisson regression with generalized additive models adjusted for confounders. Statistically significant associations were identified between PM10 and PM2.5–10 and respiratory diseases. Risks of hospitalization increased by 23.5% (95% CI: 13.5; 34.3 and 12.8% (95% CI: 6.0; 20.0 per 10 μg/m3 of PM2.5-10 and PM10, respectively. PM2.5 exhibited a significant association with circulatory system diseases, with the risk of hospitalization increasing by 19.6% (95% CI: 6.4; 34.6 per 10 μg/m3. Regarding the chemical species; SO42−, NO3−, NH4+ and K+ exhibited specific patterns of risk, relative to the investigated outcomes. Overall, SO42− in PM2.5–10 and K+ in PM2.5 were associated with increased risk of hospital admissions due to both types of diseases. The results agree with evidence indicating that the risks for different health outcomes vary in relation to the fractions and chemical composition of PM10. Thus, PM10 speciation studies may contribute to the establishment of more selective pollution control policies.

  3. Experimental investigation of MHD pressure losses in a mock-up of a liquid metal blanket

    Science.gov (United States)

    Mistrangelo, C.; Bühler, L.; Brinkmann, H.-J.

    2018-03-01

    Experiments have been performed to investigate the influence of a magnetic field on liquid metal flows in a scaled mock-up of a helium cooled lead lithium (HCLL) blanket. During the experiments pressure differences between points on the mock-up have been recorded for various values of flow rate and magnitude of the imposed magnetic field. The main contributions to the total pressure drop in the test-section have been identified as a function of characteristic flow parameters. For sufficiently strong magnetic fields the non-dimensional pressure losses are practically independent on the flow rate, namely inertia forces become negligible. Previous experiments on MHD flows in a simplified test-section for a HCLL blanket showed that the main contributions to the total pressure drop in a blanket module originate from the flow in the distributing and collecting manifolds. The new experiments confirm that the largest pressure drops occur along manifolds and near the first wall of the blanket module, where the liquid metal passes through small openings in the stiffening plates separating two breeder units. Moreover, the experimental data shows that with the present manifold design the flow does not distribute homogeneously among the 8 stacked boxes that form the breeding zone.

  4. SECURING DIGITIZED LIBRARY CIRCULATORY SYSTEM | Olaniyi ...

    African Journals Online (AJOL)

    Journal Home > Vol 35, No 3 (2016) > ... Despite the potential benefits of Information and Communication Technology (ICT) in library automation, ... The widespread application of the developed system on smart library circulation unit would ...

  5. Simulation of dilated heart failure with continuous flow circulatory support.

    Directory of Open Access Journals (Sweden)

    Yajuan Wang

    Full Text Available Lumped parameter models have been employed for decades to simulate important hemodynamic couplings between a left ventricular assist device (LVAD and the native circulation. However, these studies seldom consider the pathological descending limb of the Frank-Starling response of the overloaded ventricle. This study introduces a dilated heart failure model featuring a unimodal end systolic pressure-volume relationship (ESPVR to address this critical shortcoming. The resulting hemodynamic response to mechanical circulatory support are illustrated through numerical simulations of a rotodynamic, continuous flow ventricular assist device (cfVAD coupled to systemic and pulmonary circulations with baroreflex control. The model further incorporated septal interaction to capture the influence of left ventricular (LV unloading on right ventricular function. Four heart failure conditions were simulated (LV and bi-ventricular failure with/without pulmonary hypertension in addition to normal baseline. Several metrics of LV function, including cardiac output and stroke work, exhibited a unimodal response whereby initial unloading improved function, and further unloading depleted preload reserve thereby reducing ventricular output. The concept of extremal loading was introduced to reflect the loading condition in which the intrinsic LV stroke work is maximized. Simulation of bi-ventricular failure with pulmonary hypertension revealed inadequacy of LV support alone. These simulations motivate the implementation of an extremum tracking feedback controller to potentially optimize ventricular recovery.

  6. Development and Performance Evaluation of a Re-Circulatory Vegetable Moisturizer

    Directory of Open Access Journals (Sweden)

    M. O. Sunmonu

    2016-08-01

    Full Text Available A re-circulatory vegetable moisturizer for preventing wilting in vegetables was developed and its performance evaluation carried out. Freshly harvested Amaranthus vegetables were used for the experiments. The temperature and relative humidity were monitored daily. The vitamin A of this produce was determined at intervals of two days for 9 days. The effects of the storage parameters (temperature and relative humidity on the nutritional value of the produce were determined using statistical analysis of variance (ANOVA. Further analysis by Duncan’s New Multiple Range Test (DNMRT was carried out to compare the means. The vegetable moisturizer was evaluated by comparing the change in nutritional (vitamin A of Amaranthus vegetable with hand wetting system and no wetting condition. The results showed that the moisturizer had higher mean vitamin A content (4.93mg/100gcompared to the mean vitamin A content of the manual wetting (4.88mg/100g and no wetting condition (4.57mg/100g. The sensory characteristics showed that the Moisturizer was more desirable when compared to the manual wetting and no wetting condition after nine days. It was concluded that the Moisturizer preserved the nutritional and sensory characteristics (texture and colour better than the manual and no wetting condition as a result of lower temperature, higher relative humidity and better water draining of the Moisturizer.

  7. Experimental test campaign on an ITER divertor mock-up

    Energy Technology Data Exchange (ETDEWEB)

    Dell' Orco, G. E-mail: giovanni.dellorco@brasimone.enea.it; Malavasi, A.; Merola, M.; Polazzi, G.; Simoncini, M.; Zito, D

    2002-11-01

    In 1998, in the frame of the European R and D on ITER high heat flux components, the fabrication of a full scale ITER Divertor Outboard mock-up was launched. It comprised a Cassette Body (CB), designed with some mechanical and hydraulic simplifications with respect to the reference body and its actively cooled Dummy Armour Prototype (DAP). This DAP consists of a Vertical Target (VT), a Wing (WI) and a Dump Target (DT), manufactured by European industries, which are integrated to the Gas Box Liner (GBL) supplied by the Russian Federation ITER Home Team. In 1999, in parallel with the manufacturing activity, the ITER European Home Team decided to assign to ENEA a Task for checking the component integration and performing the thermal-hydraulic and thermal mechanical testing of the DAP and CB. In 1999-2000, ENEA performed the experimental campaign at Brasimone Labs. The present work presents the experimental results of the component integration and the thermal-hydraulic and thermo-mechanical fatigue tests.

  8. Experimental test campaign on an ITER divertor mock-up

    International Nuclear Information System (INIS)

    Dell'Orco, G.; Malavasi, A.; Merola, M.; Polazzi, G.; Simoncini, M.; Zito, D.

    2002-01-01

    In 1998, in the frame of the European R and D on ITER high heat flux components, the fabrication of a full scale ITER Divertor Outboard mock-up was launched. It comprised a Cassette Body (CB), designed with some mechanical and hydraulic simplifications with respect to the reference body and its actively cooled Dummy Armour Prototype (DAP). This DAP consists of a Vertical Target (VT), a Wing (WI) and a Dump Target (DT), manufactured by European industries, which are integrated to the Gas Box Liner (GBL) supplied by the Russian Federation ITER Home Team. In 1999, in parallel with the manufacturing activity, the ITER European Home Team decided to assign to ENEA a Task for checking the component integration and performing the thermal-hydraulic and thermal mechanical testing of the DAP and CB. In 1999-2000, ENEA performed the experimental campaign at Brasimone Labs. The present work presents the experimental results of the component integration and the thermal-hydraulic and thermo-mechanical fatigue tests

  9. Mock Site Licensing Demonstration Project. Final report

    International Nuclear Information System (INIS)

    Roop, R.D.

    1986-06-01

    The Mock Site Licensing Demonstration Project developed the Low-Level Radioactive Waste Siting Simulation, a role-playing exercise designed to facilitate the process of siting and licensing disposal facilities for low-level waste (LLW). This report describes the development, contant, and usefulness of the siting simulation. The simulation was designed by Harvard University's Program on Negotiation; it can be conducted at a workshop or conference, involves 14 or more participants, and requires about eight hours to complete. The simulation consists of two sessions. In the first, participants negotiate the selection of siting criteria, and in the second, a preferred site for a facility is chosen from three candidate sites. The project sponsored two workshops (in Boston, Massachusetts and Richmond, Virginia) in which the simulation was conducted for persons involved in planning for LLW. It is concluded that the siting simulation can be useful in three ways: (1) as a tool for information dissemination, (2) as a vehicle that can foste communication among parties in conflict, and (3) as a step toward consensus building and conflict resolution. The DOE National Low-Level Waste Management Program is now making the siting simulation available for use by states, regional compacts, and other organizations involved in development of LLW disposal facilities

  10. Dynamics of Short-Term Phosphorus Uptake by Intact Mycorrhizal and Non-mycorrhizal Maize Plants Grown in a Circulatory Semi-Hydroponic Cultivation System.

    Science.gov (United States)

    Garcés-Ruiz, Mónica; Calonne-Salmon, Maryline; Plouznikoff, Katia; Misson, Coralie; Navarrete-Mier, Micaela; Cranenbrouck, Sylvie; Declerck, Stéphane

    2017-01-01

    A non-destructive cultivation system was developed to study the dynamics of phosphorus (Pi) uptake by mycorrhizal and non-mycorrhizal maize plantlets. The system consisted of a plant container connected via silicon tubes to a glass bottle containing a nutrient solution supplemented with Pi. The nutrient solution is pumped with a peristaltic pump to the upper part of the container via the silicon tubes and the solution percolate through the plantlet container back into the glass bottle. Pi is sampled from the glass bottle at regular intervals and concentration evaluated. Maize plantlets were colonized by the AMF Rhizophagus irregularis MUCL 41833 and Pi uptake quantified at fixed intervals (9, 21, and 42 h) from the depletion of the Pi in the nutrient solution flowing through the plantlets containers. Plants and fungus grew well in the perlite substrate. The concentration of Pi in the bottles followed an almost linear decrease over time, demonstrating a depletion of Pi in the circulating solution and a concomitant uptake/immobilization by the plantlet-AMF associates in the containers. The Pi uptake rate was significantly increased in the AMF-colonized plantlets (at 9 and 21 h) as compared to non-colonized plantlets, although no correlation was noticed with plant growth or P accumulation in shoots. The circulatory semi-hydroponic cultivation system developed was adequate for measuring Pi depletion in a nutrient solution and by corollary Pi uptake/immobilization by the plant-AMF associates. The measurements were non-destructive so that the time course of Pi uptake could be monitored without disturbing the growth of the plant and its fungal associate. The system further opens the door to study the dynamics of other micro and macro-nutrients as well as their uptake under stressed growth conditions such as salinity, pollution by hydrocarbon contaminants or potential toxic elements.

  11. Dynamics of Short-Term Phosphorus Uptake by Intact Mycorrhizal and Non-mycorrhizal Maize Plants Grown in a Circulatory Semi-Hydroponic Cultivation System

    Directory of Open Access Journals (Sweden)

    Mónica Garcés-Ruiz

    2017-08-01

    Full Text Available A non-destructive cultivation system was developed to study the dynamics of phosphorus (Pi uptake by mycorrhizal and non-mycorrhizal maize plantlets. The system consisted of a plant container connected via silicon tubes to a glass bottle containing a nutrient solution supplemented with Pi. The nutrient solution is pumped with a peristaltic pump to the upper part of the container via the silicon tubes and the solution percolate through the plantlet container back into the glass bottle. Pi is sampled from the glass bottle at regular intervals and concentration evaluated. Maize plantlets were colonized by the AMF Rhizophagus irregularis MUCL 41833 and Pi uptake quantified at fixed intervals (9, 21, and 42 h from the depletion of the Pi in the nutrient solution flowing through the plantlets containers. Plants and fungus grew well in the perlite substrate. The concentration of Pi in the bottles followed an almost linear decrease over time, demonstrating a depletion of Pi in the circulating solution and a concomitant uptake/immobilization by the plantlet-AMF associates in the containers. The Pi uptake rate was significantly increased in the AMF-colonized plantlets (at 9 and 21 h as compared to non-colonized plantlets, although no correlation was noticed with plant growth or P accumulation in shoots. The circulatory semi-hydroponic cultivation system developed was adequate for measuring Pi depletion in a nutrient solution and by corollary Pi uptake/immobilization by the plant-AMF associates. The measurements were non-destructive so that the time course of Pi uptake could be monitored without disturbing the growth of the plant and its fungal associate. The system further opens the door to study the dynamics of other micro and macro-nutrients as well as their uptake under stressed growth conditions such as salinity, pollution by hydrocarbon contaminants or potential toxic elements.

  12. Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.

    Science.gov (United States)

    Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki

    2016-08-01

    The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.

  13. History of Bioelectrical Study and the Electrophysiology of the Primo Vascular System

    Directory of Open Access Journals (Sweden)

    Sang Hyun Park

    2013-01-01

    Full Text Available Background. Primo vascular system is a new anatomical structure whose research results have reported the possibility of a new circulatory system similar to the blood vascular system and cells. Electrophysiology, which measures and analyzes bioelectrical signals tissues and cells, is an important research area for investigating the function of tissues and cells. The bioelectrical study of the primo vascular system has been reported by using modern techniques since the early 1960s by Bonghan Kim. This paper reviews the research result of the electrophysiological study of the primo vascular system for the discussion of the circulatory function. We hope it would help to study the electrophysiology of the primo vascular system for researchers. This paper will use the following exchangeable expressions: Kyungrak system = Bonghan system = Bonghan circulatory system = primo vascular system = primo system; Bonghan corpuscle = primo node; Bonghan duct = primo vessel. We think that objective descriptions of reviewed papers are more important than unified expressions when citing the papers. That said, this paper will unify the expressions of the primo vascular system.

  14. Inspection of heat transfer tubes after mock-up tests of miniaturized apparatus for the acid recovery evaporator. Contract research

    International Nuclear Information System (INIS)

    Hamada, Shozo; Fukaya, Kiyoshi; Kato, Chiaki; Yanagihara, Takao; Doi, Masamitu; Kiuchi, Kiyoshi

    2001-10-01

    The demonstration test for the acid recovery evaporator and the dissolver used in the major equipment of Rokkasho Reprocessing Plant (RRP), has been carried out. The mock-up miniature equipment has been employed to it. This test had been performed from April in 1998. The total time of demonstration test using the mock-up equipment is about two and half years, which corresponds to about 20,000 hours. After that, four of the seven heat transfer tubes used in the evaporator were drawn out and the corrosion level and the mechanical properties were evaluated for one of them. As a result, intergranular corrosion was recognized in the inner surface of the heat transfer tube and the corrosion depth at the grain boundary was statistically shown to be about one grain from the inner surface. Further, no change in mechanical properties was observed and growth of intergranular cracks in the inner surface of the specimen was found after flattering test. (author)

  15. Neutronics Experiment on A HCPB Breeder Blanket Mock-Up

    International Nuclear Information System (INIS)

    Paola Batistoni, P.; Angelone, M.; Bettinali, L.

    2006-01-01

    A neutronics experiment has been performed in the frame of European Fusion Technology Program on a mock-up of the EU Test Blanket Module (TBM), Helium Cooled Pebble Bed (HCPB) concept, with the objective to validate the capability of nuclear data to predict nuclear responses, such as the tritium production rate (TPR), with qualified uncertainties. The experiment has been carried out at the FNG 14-MeV neutron source in collaboration between ENEA, Technische Universitaet Dresden, Forschungszentrum Karlsruhe, J. Stefan Institute Ljubljana and with the participation of JAEA. The mock-up, designed in such a way to replicate all relevant nuclear features of the TBM-HCPB, consisted of a steel box containing beryllium block and two intermediate steel cassettes, filled with of Li 2 CO 3 powder, replicating the breeder insert main characteristics: radial thickness, distance between ceramic layers, thickness of ceramic layers and of steel walls. In the experiment, the TPR has been measured using Li 2 CO 3 pellets at various depths at two symmetrical positions at each depth, one in the upper and one in the lower cassette. Twelve pellets were used at each position to determine the TPR profile through the cassette. Three independent measurements were performed by ENEA, TUD/VKTA and JAEA. The neutron flux in the beryllium layer was measured as well using activation foils. The measured tritium production in the TBM (E) was compared with the same quantity (C) calculated by the MCNP.4c using a very detailed model of the experimental set up, and using neutron cross sections from the European Fusion File (EFF ver.3.1) and from the Fusion Evaluated Nuclear Data Library (FENDL ver. 2.1, ITER reference neutron library). C/E ratios were obtained with a total uncertainty on the C/E comparison less than 9% (2 s). A sensitivity and uncertainty analysis has also been performed to evaluate the calculation uncertainty due to the uncertainty on neutron cross sections. The results of such

  16. Inactive trials of transport systems

    International Nuclear Information System (INIS)

    Haberlin, M.M.; Hardy, A.R.

    1985-06-01

    The design and manufacture of a mock-up of a crate handling and size reduction (CHSR) facility, an experimental programme on the evaluation of a commercial air-transporter, and the selection, manufacture and commissioning trials of an integrated conveyor system for transporting crated waste into and within the mock-up facility, are considered. The mock-up facility was used for the test programme on the air-transporter and conveyor system. The air-transporter was considered suitable for transporting waste on the metal floor in the main dismantling area of the CHSR facility because it can tolerate asymmetric loading, the exhaust air flow liberated from the air-pads is low and it has excellent manoeuvrability. Commissioning trials were carried out on a commercial conveyor system consisting of unpowered rollers in the reception area, a powered slatted conveyor in the air-lock and an unpowered roller table placed on the air-transporter in the working area. It was demonstrated that a large asymmetrically loaded wooden crate can be transported into and within the facility by this method. Further design and experimental work necessary before the system can be used for remote operation is discussed. (author)

  17. Infectious and inflammatory disorders of the circulatory system as risk factors for stroke in Saudi children

    International Nuclear Information System (INIS)

    Salih, Mustafa A.; Al-Jarallah, Ahmed A.; Kentab, Anal Y.; Zahraa, Jihad N.; Abdel-Gader, Mohamed O.; Gadelrab, Mohamed O.; Alorainy, Ibrahim A.; Hassan, Hamdy H.

    2006-01-01

    Objective was to report on the role of infectious and inflammatory disorders as risk factors for stroke in a prospective and retrospective cohort of Saudi children. Children, who presented with stroke, were evaluated at the Division of Pediatric Neurology or admitted to King Khalid University Hospital, College of Medicine, King Saud University, Riyadh, Kingdom of Saudi Arabia during the periods July 1992 to February 2001 (retrospective study) and February 2001 to March 2003 (prospective study). Investigations for suspected cases included haemostatic assays, microbiological and serological tests. Neuroimaging included cranial CT, MRI magnetic resonance angiography (MRA), magnetic resonance venography (MRV) and single photon emission computed tomography (SPECT) brain scan. Of the 104 Saudi children with stroke, seen during the combined study periods of 10 years and 7 months, infectious and inflammatory disorders of the circulatory systems were identified risk factors in 18 (17.3%). Five children had stroke following acute bacterial meningitis at ages ranging between 5-21 months. The causative organism was identified in 3 of them and consisted of Haemophilus influenza (in a 5-months-old girl), Streptococcus pneumonia (in a 21-months-old girl complicated by subdural empyema and sinovenous thrombosis), and Staphylococcus aureus in a 6-months-old boy who had an underlying chronic granulomatous disease. Unspecified meningitis/meningoencephalitis affected 4 patients, whereas 3 children had an underlying congenital infection as a cause for their stroke. Two of the latter 3 children were diagnosed to have congenital toxoplasmosis, and the third had congenital rubella syndrome. Two girls had stroke following septicemia at ages of one and 2 months. Neurobrucellosis caused stroke in 2 boys at the ages of 4 1/2 and 4 years. In both patients, neuroimaging revealed lacunar and other infects involving mainly the deep cerebral nuclei, secondary to occlusion of small penetrating end

  18. Modeling the heart and the circulatory system

    CERN Document Server

    2015-01-01

    The book comprises contributions by some of the most respected scientists in the field of mathematical modeling and numerical simulation of the human cardiocirculatory system. The contributions cover a wide range of topics, from the preprocessing of clinical data to the development of mathematical equations, their numerical solution, and both in-vivo and in-vitro validation. They discuss the flow in the systemic arterial tree and the complex electro-fluid-mechanical coupling in the human heart. Many examples of patient-specific simulations are presented. This book is addressed to all scientists interested in the mathematical modeling and numerical simulation of the human cardiocirculatory system.

  19. Exploring employment readiness through mock job interview and workplace role-play exercises: comparing youth with physical disabilities to their typically developing peers.

    Science.gov (United States)

    Lindsay, Sally; McDougall, Carolyn; Sanford, Robyn; Menna-Dack, Dolly; Kingsnorth, Shauna; Adams, Tracey

    2015-01-01

    To assess performance differences in a mock job interview and workplace role-play exercise for youth with disabilities compared to their typically developing peers. We evaluated a purposive sample of 31 youth (15 with a physical disability and 16 typically developing) on their performance (content and delivery) in employment readiness role-play exercises. Our findings show significant differences between youth with disabilities compared to typically developing peers in several areas of the mock interview content (i.e. responses to the questions: "tell me about yourself", "how would you provide feedback to someone not doing their share" and a problem-solving scenario question) and delivery (i.e. voice clarity and mean latency). We found no significant differences in the workplace role-play performances of youth with and without disabilities. Youth with physical disabilities performed poorer in some areas of a job interview compared to their typically developing peers. They could benefit from further targeted employment readiness training. Clinicians should: Coach youth with physical disability on how to "sell" their abilities to potential employers and encourage youth to get involved in volunteer activities and employment readiness training programs. Consider using mock job interviews and other employment role-play exercises as assessment and training tools for youth with physical disabilities. Involve speech pathologists in the development of employment readiness programs that address voice clarity as a potential delivery issue.

  20. Monitoring and assay procedures for krypton-85 used in circulatory tests

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Jr., J. M.; Williams, K. D.

    1963-11-15

    During the past five years, krypton-85 has been used extensively at the National Institutes of health and by the heart Catheterization laboratory in the identification of circulatory shunts. Several methods of assaying the incoming shipments of radioactive gas are given. These consist of ionization chamber measurements, gamma ray spectrometry, and gross photon counting of the cylinder surface with an end-window Geiger-Mueller tube. A device (consisting of a log-count-rate meter, recorder, and G.M. tube) is used to continuously monitor the laboratory. The method of calibrating this device is presented. A means for removing contaminated air from the vicinity of the operating table was devised. The results of air clearance studies of the room are included. (auth)

  1. Mock Hospital Ethics Committee: An Innovative Simulation to Teach Prelicensure Nursing Students the Complexities of Ethics in Practice.

    Science.gov (United States)

    Hagedorn Wonder, Amy

    Limited opportunities exist for prelicensure nursing students to observe the interprofessional process required to resolve complex ethical cases in practice. Therefore, a mock hospital ethics committee (MHEC) was assembled to teach the application of ethics in practice through simulation. The MHEC meeting is an example of how nursing education and practice can partner to create meaningful learning experiences.

  2. Bridge to recovery in two cases of dilated cardiomyopathy after long-term mechanical circulatory support

    OpenAIRE

    Pacholewicz, Jerzy; Zakliczy?ski, Micha?; Kowalik, Violetta; Nadziakiewicz, Pawe?; Kowalski, Oskar; Kalarus, Zbigniew; Zembala, Marian

    2014-01-01

    Ventricular assist devices (VADs) have become an established therapeutic option for patients with end-stage heart failure. Achieving the potential for recovery of native heart function using VADs is an established form of treatment in a selected group of patients with HF. We report two cases of VAD patients with different types of pump used for mechanical circulatory support, a continuous flow pump (Heart-Ware?) and a pulsatile pump (POLVAD MEV?), which allow regeneration of the native heart....

  3. Evolutionary morphology of the hemolymph vascular system of basal araneomorph spiders (Araneae: Araneomorphae).

    Science.gov (United States)

    Huckstorf, Katarina; Michalik, Peter; Ramírez, Martín; Wirkner, Christian S

    2015-11-01

    The superfamily Austrochiloidea (Austrochilidae and Gradungulidae) take a pivotal position in araneomorph spider phylogeny. In this discussion crevice weaver spiders (Filistatidae) are of equal interest. Especially data from these phylogenetically uncertain yet basal off branching groups can enlighten our understanding on the evolution of organ systems. In the course of a survey on the evolutionary morphology of the circulatory system in spiders we therefore investigated the hemolymph vascular system in two austrochiloid and one filistatid species. Additionally some data on a hypochilid and a gradungulid species are included. Using up-to-date morphological methods, the vascular systems in these spiders are visualized three dimensionally. Ground pattern features of the circulatory systems in austrochiloid spiders are presented and the data discussed along recent lines of phylogenetic hypotheses. Special topics highlighted are the intraspecific variability of the origins of some prosomal arteries and the evolutionary correlation of respiratory and circulatory systems in spiders. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. The Mock LISA Data Challenges: from challenge 3 to challenge 4

    International Nuclear Information System (INIS)

    Babak, Stanislav; Petiteau, Antoine; Robinson, Emma L; Baker, John G; McWilliams, Sean T; Arnaud, Keith A; Benacquista, Matthew J; Cornish, Neil J; Adams, Matt; Larson, Shane L; Mandel, Ilya; Porter, Edward K; Vallisneri, Michele; Cutler, Curt; Vecchio, Alberto; Blaut, Arkadiusz; Bridges, Michael; Feroz, Farhan; Cohen, Michael; Gair, Jonathan R.

    2010-01-01

    The Mock LISA Data Challenges are a program to demonstrate LISA data-analysis capabilities and to encourage their development. Each round of challenges consists of one or more datasets containing simulated instrument noise and gravitational waves from sources of undisclosed parameters. Participants analyze the datasets and report best-fit solutions for the source parameters. Here we present the results of the third challenge, issued in April 2008, which demonstrated the positive recovery of signals from chirping galactic binaries, from spinning supermassive-black-hole binaries (with optimal SNRs between ∼10 and 2000), from simultaneous extreme-mass-ratio inspirals (SNRs of 10-50), from cosmic-string-cusp bursts (SNRs of 10-100), and from a relatively loud isotropic background with Ω gw (f) ∼ 10 -11 , slightly below the LISA instrument noise.

  5. The Mock LISA Data Challenges: from challenge 3 to challenge 4

    Energy Technology Data Exchange (ETDEWEB)

    Babak, Stanislav; Petiteau, Antoine; Robinson, Emma L [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut), Am Muehlenberg 1, D-14476 Golm bei Potsdam (Germany); Baker, John G; McWilliams, Sean T; Arnaud, Keith A [Gravitational Astrophysics Laboratory, NASA Goddard Space Flight Center, 8800 Greenbelt Rd, Greenbelt, MD 20771 (United States); Benacquista, Matthew J [Center for Gravitational Wave Astronomy, University of Texas at Brownsville, Brownsville, TX 78520 (United States); Cornish, Neil J; Adams, Matt [Department of Physics, Montana State University, Bozeman, MT 59717 (United States); Larson, Shane L [Department of Physics, Utah State University, Logan, UT 84322 (United States); Mandel, Ilya [Department of Physics and Astronomy, Northwestern University, Evanston, IL (United States); Porter, Edward K [APC, UMR 7164, University Paris 7 Denis Diderot, 10, rue Alice Domon et Leonie Duquet, 75025 Paris Cedex 13 (France); Vallisneri, Michele; Cutler, Curt [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Vecchio, Alberto [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B152TT (United Kingdom); Blaut, Arkadiusz [Institute of Theoretical Physics, University of Wroclaw, Wroclaw (Poland); Bridges, Michael; Feroz, Farhan [Astrophysics Group, Cavendish Laboratory, University of Cambridge, Cambridge CB30HE (United Kingdom); Cohen, Michael [Theoretical Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Gair, Jonathan R., E-mail: Michele.Vallisneri@jpl.nasa.go [Institute of Astronomy, University of Cambridge, Cambridge CB30HA (United Kingdom)

    2010-04-21

    The Mock LISA Data Challenges are a program to demonstrate LISA data-analysis capabilities and to encourage their development. Each round of challenges consists of one or more datasets containing simulated instrument noise and gravitational waves from sources of undisclosed parameters. Participants analyze the datasets and report best-fit solutions for the source parameters. Here we present the results of the third challenge, issued in April 2008, which demonstrated the positive recovery of signals from chirping galactic binaries, from spinning supermassive-black-hole binaries (with optimal SNRs between approx10 and 2000), from simultaneous extreme-mass-ratio inspirals (SNRs of 10-50), from cosmic-string-cusp bursts (SNRs of 10-100), and from a relatively loud isotropic background with OMEGA{sub gw}(f) approx 10{sup -11}, slightly below the LISA instrument noise.

  6. Sperm cell purification from mock forensic swabs using SOMAmer™ affinity reagents.

    Science.gov (United States)

    Katilius, Evaldas; Carmel, Andrew B; Koss, Heidi; O'Connell, Dan; Smith, Breanna C; Sanders, Glenn M; LaBerge, Greggory S

    2018-03-27

    We have demonstrated a proof of concept with affinity-based purification of sperm cells from mock forensic samples using SOMAmer™ reagents, DNA-based affinity reagents developed by SomaLogic, Inc. SOMAmer reagents were selected in vitro using whole-cell SELEX to bind specifically with intact, detergent-treated sperm cells. Successful separation of sperm from epithelial cells and their debris was demonstrated using buccal swabs with added semen. Primarily male DNA profiles were generated from sperm cells eluted from the types of cotton swabs typically used for rape kit evidence collection. The quality of sperm DNA isolated from samples purified using SOMAmers is comparable to existing commercially available differential extraction-based methods at higher sperm concentrations. This purification method is simple, offers relatively rapid (forensic casework. Copyright © 2018. Published by Elsevier B.V.

  7. The analysis of the cases of circulatory and respiratory arrest in the work of the Regional Unit of Ambulance Service - Sródmieście Station.

    Science.gov (United States)

    Chemperek, Ewa; Mikuła, Agnieszka; Goniewicz, Mariusz; Krawczyk, Wojciech

    2004-01-01

    The major causes of deaths all over the world are circulatory system diseases, neoplasms and injuries. Each man can become a participant of the event which results in life-threatening emergencies and the most immediate possible actions are essential. The period of time for starting efficient life-restoration actions is very short, estimated at 4-5 minutes. Ambulance Service is a medical organization created to apply aid in life-threatening emergencies. The standards of the developed western countries determine the arrival time at 7-10 minutes from the call time. Both first-aid applied by the accident witnesses and efficient actions of ambulance service have significance for effective pre-hospital aid and increasing the chances of survival of people in need. The study analysed emergency records of the ambulance cars of the Regional Unit of Ambulance Service - Sródmieście Station in Lublin in the year 2000. 3,723 calls were recorded. In 142 cases complete resuscitation actions were carried out due to circulatory and respiratory arrest. The records selected this way went through a detailed analysis. In 3.8% of the interventions of emergency teams the necessity of applying advanced life support was observed. The time of arrival at the scene, transport of the patient to the admission room as well as efficiency of resuscitation comply with the European standards. The efficiency of resuscitation actions estimated at 51.4% depended on the age of the patient, the cause of circulatory and respiratory arrest and ambulance arrival time. Taking up basic life support by witnesses of the event was observed in 2.8% of cases, in 8.5% aid was applied by the medical staff members who happened to be at the scene.

  8. First steps in designing an all-in-one ICT-based device for persons with cognitive impairment: evaluation of the first mock-up.

    Science.gov (United States)

    Boman, Inga-Lill; Persson, Ann-Christine; Bartfai, Aniko

    2016-03-07

    This project Smart Assisted Living involving Informal careGivers++ (SALIG) intends to develop an ICT-based device for persons with cognitive impairment combined with remote support possibilities for significant others and formal caregivers. This paper presents the identification of the target groups' needs and requirements of such device and the evaluation of the first mock-up, demonstrated in a tablet. The inclusive design method that includes end-users in the design process was chosen. First, a scoping review was conducted in order to examine the target group's need of an ICT-based device, and to gather recommendations regarding its design and functionalities. In order to capture the users' requirements of the design and functionalities of the device three targeted focus groups were conducted. Based on the findings from the publications and the focus groups a user requirement specification was developed. After that a design concept and a first mock-up was developed in an iterative process. The mock-up was evaluated through interviews with persons with cognitive impairment, health care professionals and significant others. Data were analysed using content analysis. Several useful recommendations of the design and functionalities of the SALIG device for persons with cognitive impairment were identified. The main benefit of the mock-up was that it was a single device with a set of functionalities installed on a tablet and designed for persons with cognitive impairment. An additional benefit was that it could be used remotely by significant others and formal caregivers. The SALIG device has the potentials to facilitate everyday life for persons with cognitive impairment, their significant others and the work situation for formal caregivers. The results may provide guidance in the development of different types of technologies for the target population and for people with diverse disabilities. Further work will focus on developing a prototype to be empirically tested

  9. Uncertainty analysis and flow measurements in an experimental mock-up of a molten salt reactor concept

    Energy Technology Data Exchange (ETDEWEB)

    Yamaji, Bogdan; Aszodi, Attila [Budapest University of Technology and Economics (Hungary). Inst. of Nuclear Techniques

    2016-09-15

    In the paper measurement results from the experimental modelling of a molten salt reactor concept will be presented along with detailed uncertainty analysis of the experimental system. Non-intrusive flow measurements are carried out on the scaled and segmented mock-up of a homogeneous, single region molten salt fast reactor concept. Uncertainty assessment of the particle image velocimetry (PIV) measurement system applied with the scaled and segmented model is presented in detail. The analysis covers the error sources of the measurement system (laser, recording camera, etc.) and the specific conditions (de-warping of measurement planes) originating in the geometry of the investigated domain. Effect of sample size in the ensemble averaged PIV measurements is discussed as well. An additional two-loop-operation mode is also presented and the analysis of the measurement results confirm that without enhancement nominal and other operation conditions will lead to strong unfavourable separation in the core flow. It implies that use of internal flow distribution structures will be necessary for the optimisation of the core coolant flow. Preliminary CFD calculations are presented to help the design of a perforated plate located above the inlet region. The purpose of the perforated plate is to reduce recirculation near the cylindrical wall and enhance the uniformity of the core flow distribution.

  10. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    International Nuclear Information System (INIS)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok

    2001-01-01

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p 2 =0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  11. Autonomous identification of matrices in the APNea system

    International Nuclear Information System (INIS)

    Hensley, D.

    1995-01-01

    The APNea System is a passive and active neutron assay device which features imaging to correct for nonuniform distributions of source material. Since the imaging procedure requires a detailed knowledge of both the detection efficiency and the thermal neutron flux for (sub)volumes of the drum of interest, it is necessary to identify which mocked-up matrix, to be used for detailed characterization studies, best matches the matrix of interest. A methodology referred to as the external matrix probe (EMP) has been established which links external measures of a drum matrix to those of mocked-up matrices. These measures by themselves are sufficient to identify the appropriate mock matrix, from which the necessary characterization data are obtained. This independent matrix identification leads to an autonomous determination of the required system response parameters for the assay analysis

  12. Multiple D3-Instantons and Mock Modular Forms II

    Science.gov (United States)

    Alexandrov, Sergei; Banerjee, Sibasish; Manschot, Jan; Pioline, Boris

    2018-03-01

    We analyze the modular properties of D3-brane instanton corrections to the hypermultiplet moduli space in type IIB string theory compactified on a Calabi-Yau threefold. In Part I, we found a necessary condition for the existence of an isometric action of S-duality on this moduli space: the generating function of DT invariants in the large volume attractor chamber must be a vector-valued mock modular form with specified modular properties. In this work, we prove that this condition is also sufficient at two-instanton order. This is achieved by producing a holomorphic action of {SL(2,Z)} on the twistor space which preserves the holomorphic contact structure. The key step is to cancel the anomalous modular variation of the Darboux coordinates by a local holomorphic contact transformation, which is generated by a suitable indefinite theta series. For this purpose we introduce a new family of theta series of signature (2, n - 2), find their modular completion, and conjecture sufficient conditions for their convergence, which may be of independent mathematical interest.

  13. Multiple D3-instantons and mock modular forms I

    CERN Document Server

    Alexandrov, Sergei; Manschot, Jan; Pioline, Boris

    2017-01-01

    We study D3-instanton corrections to the hypermultiplet moduli space in type IIB string theory compactified on a Calabi-Yau threefold. In a previous work, consistency of D3-instantons with S-duality was established at first order in the instanton expansion, using the modular properties of the M5-brane elliptic genus. We extend this analysis to the two-instanton level, where wall-crossing phenomena start playing a role. We focus on the contact potential, an analogue of the Kahler potential which must transform as a modular form under S-duality. We show that it can be expressed in terms of a suitable modification of the partition function of D4-D2-D0 BPS black holes, constructed out of the generating function of MSW invariants (the latter coincide with Donaldson-Thomas invariants in a particular chamber). Modular invariance of the contact potential then requires that, in case where the D3-brane wraps a reducible divisor, the generating function of MSW invariants must transform as a vector-valued mock modular fo...

  14. Neonatal aortic arch reconstruction avoiding circulatory arrest and direct arch vessel cannulation.

    Science.gov (United States)

    Tchervenkov, C I; Korkola, S J; Shum-Tim, D; Calaritis, C; Laliberté, E; Reyes, T U; Lavoie, J

    2001-11-01

    Aortic arch reconstruction in neonates routinely requires deep hypothermic circulatory arrest. We reviewed our experience with techniques of continuous low-flow cerebral perfusion (LFCP) avoiding direct arch vessel cannulation. Eighteen patients, with a median age of 11 days (range 1 to 85 days) and a mean weight of 3.2 +/- 0.8 kg, underwent aortic arch reconstruction with LFCP. Seven had biventricular repairs with arch reconstruction, 9 underwent the Norwood operation and 2 had isolated arch repairs. In 1 Norwood and 7 biventricular repair patients, LFCP was maintained by advancing the cannula from the distal ascending aorta into the innominate artery. In 8 of 9 Norwood patients, LFCP was maintained by directing the arterial cannula into the pulmonary artery confluence and perfusing the innominate artery through the right modified Blalock-Taussig shunt fully constructed before cannulation for cardiopulmonary bypass. In 2 patients requiring isolated arch reconstruction, the ascending aorta was cannulated and the cross-clamp was applied just distal to the innominate artery. LFCP was maintained at 0.6 +/- 0.2 L x min(-1) x m(-2) for 41.0 +/- 13.9 minutes at 18.5 degrees C +/- 1.1 degrees C. In 10 of the 18 patients, blood pressure during LFCP was 15 +/- 8 mm Hg remote from the innominate artery (left radial, umbilical or femoral arteries). In 8 of the 18 patients, right radial pressure during LFCP was 24 +/- 10 mm Hg. The mean mixed-venous saturation was 79.8% +/- 10% during LFCP. Two patients had preoperative seizures, whereas none had seizures postoperatively. One patient died. Neonatal aortic arch reconstruction is possible without circulatory arrest or direct arch vessel cannulation. These techniques maintained adequate mixed-venous oxygen saturations with no associated adverse neurologic outcomes.

  15. Is there an association of circulatory hospitalizations independent of mining employment in coal-mining and non-coal-mining counties in west virginia?

    Science.gov (United States)

    Talbott, Evelyn O; Sharma, Ravi K; Buchanich, Jeanine; Stacy, Shaina L

    2015-04-01

    Exposures associated with coal mining activities, including diesel fuel exhaust, products used in coal processing, and heavy metals and other forms of particulate matter, may impact the health of nearby residents. We investigated the relationships between county-level circulatory hospitalization rates (CHRs) in coal and non-coal-mining communities of West Virginia, coal production, coal employment, and sociodemographic factors. Direct age-adjusted CHRs were calculated using West Virginia hospitalizations from 2005 to 2009. Spatial regressions were conducted to explore associations between CHR and total, underground, and surface coal production. After adjustment, neither total, nor surface, nor underground coal production was significantly related to rate of hospitalization for circulatory disease. Our findings underscore the significant role sociodemographic and behavioral factors play in the health and well-being of coal mining communities.

  16. Prophenoloxidase system, lysozyme and protease inhibitor distribution in the common cuttlefish Sepia officinalis.

    Science.gov (United States)

    Le Pabic, Charles; Safi, Georges; Serpentini, Antoine; Lebel, Jean-Marc; Robin, Jean-Paul; Koueta, Noussithé

    2014-01-01

    The immune system of cephalopods remains poorly understood. The aim of this study was to determine the specific activity of immune enzymes in epithelial barriers, circulatory and digestive systems of the common cuttlefish Sepia officinalis. Three enzyme groups with putative functions in immunity were investigated: phenoloxidases (POs), lysozymes and protease inhibitors (PIs). Consistent with a role in immunity, highest PO activities were found in the integument as well as the respiratory and circulatory organs under zymogenic (proPO) and active form. Surprisingly, high PO activities were also found in the digestive gland and its appendages. Similarly, high lysozyme activities were detected in the integument and circulatory organs, but also in the posterior salivary glands, highlighting the implication of this antibacterial enzyme group in most tissues exposed to the environment but also within the circulatory system. Albeit highest in digestive organs, the ubiquitous detection of PI activity in assayed compartments suggests immune function(s) in a wide range of tissues. Our study reports proPO/PO, lysozyme and PI distributions in S. officinalis body compartments for the first time, and thus provides the fundamental basis for a better understanding of the humoral immune system in cephalopods as well as invertebrates. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. FY2000 report of the research results of medical/engineering cooperative research project, basic research on systems for minimally invasive diagnostic/treatment of circulatory system diseases, including prognostic diagnosis; 2000 nendo igaku kogaku renkeigata kenkyu jigyo, junkankikei shikkan ni taisuru yogo shindan wo fukumu teishinshu shindan chiryo system ni kansuru kiso kenkyu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The basic researches on minimally invasive diagnostic/treatment systems are conducted for circulatory system diseases, and the FY 2000 results are reported. The program for developing the heart surgery supporting manipulator includes development of the manipulator of 7 degree of freedom and fail-safe mechanisms to be incorporated in the patient-side system, and research and development of the heart motion compensation type robot system. The program for developing the diagnosis/treatment system aided by intravascular optical analysis includes development of intravascular endoscopy by the aid of LED emitting blue color of high brightness, and automatic analyzer for the in vivo vascular endothelial cell functions. The program for the minimally invasive diagnostic system includes development of superimposing system for integrating the images by the NOGA system and cine-coronary angiography. The other R and D items include artificial vascular systems to be put in the blood vessels, adhesives for a living body, suture instruments for fine blood vessels, heart surgery supporting system, based on the infrared spectroscopy, endoscopic system for the cranical bones, arterialization method, and gene-aided treatment. (NEDO)

  18. Investigation of the Phenomenon of Propagated Sensation along the Channels in the Upper Limb Following Administration of Acupuncture and Mock Laser.

    Science.gov (United States)

    Razavy, Shohreh; Gadau, Marcus; Zhang, Shi Ping; Wang, Fu Chun; Bangrazi, Sergio; Berle, Christine; Harahap, Mahrita; Li, Tie; Li, Wei Hong; Zaslawski, Christopher

    2017-10-01

    Similar to De Qi psychophysical responses, propagated sensation along the channels (PSC) is considered an important phenomenon in traditional Chinese acupuncture. In acupuncture clinical trials, different acupuncture manipulation techniques are used to enhance the propagation of sensation along the channels to facilitate an optimum therapeutic result. To examine and compare the PSC reported by participants in a clinical trial following the administration of acupuncture and inactive mock laser. The study was embedded in a two-arm parallel design multicenter, randomized clinical trial, the Tennis Elbow Acupuncture-International Study-China, Hong Kong, Australia, Italy (TEA IS CHAI). Needle sensations were measured using a validated instrument, the Massachusetts General Hospital Acupuncture Sensation Spreading Scale. Ninety-six participants with lateral elbow pain were randomly allocated into two groups in a 1:1 ratio; the acupuncture treatment group (n = 47) and the mock laser control group (n = 49). Participants in both groups received the intervention at two acupoints, LI10 and LI11, consisting of 2 minutes of either standardized needle manipulation or mock laser at each acupoint with a rest period between each intervention period. Data were collected immediately following the interventions at the first and the ninth session within the clinical trial. Although participants in both groups perceived PSC radiating to similar sites along the upper limb, the frequency of the reported radiation sites among the two intervention groups for both radiation up the limb (p sensation sites recorded within the two study groups, the sensations were reported as radiating a greater distance down the forearm to the wrist compared to up the arm. Evaluation of PSC across the four study sites revealed a statistically significant difference in frequency of the reported radiation down the limb sites in each study group and radiation up the limb sites only in control group only (p

  19. Transfusion-associated circulatory overload (TACO: prevention, management, and patient outcomes

    Directory of Open Access Journals (Sweden)

    Roubinian NH

    2015-04-01

    Full Text Available Nareg H Roubinian,1,2 Edward L Murphy1–3 1Blood Systems Research Institute, 2Department of Laboratory Medicine, 3Department of Epidemiology and Biostatistics, University of California San Francisco, San Francisco, CA, USA Abstract: Transfusion-associated circulatory overload (TACO is acute pulmonary edema associated with left atrial hypertension or volume overload occurring within 6 hours following a blood transfusion. Recognized by physicians as a common complication of blood transfusion, its incidence has been difficult to measure because active surveillance is required to counteract underreporting; active surveillance indicates overall incidence rates as high as 1% per transfused patient. Recent clinical and translational research has focused on the development of electronic alert systems to measure TACO incidence and provide alerts to physicians regarding patients at high risk. Translational research regarding the utility of biomarkers such as brain natriuretic protein (BNP or N-terminal pro-BNP (NT-proBNP as diagnostic tools for TACO has been only moderately successful, but the search for other biomarkers continues. Prevention strategies can be developed based upon evidence derived from both observational studies and might include: using documented risk factors to highlight patients at risk, preferably using real-time analysis of electronic medical records; implementation of modified transfusion strategies to minimize the volume and infusion rate of blood products; consideration of prophylactic diuretic therapy; and heightened diagnostic awareness combined with rapid implementation of treatment. Randomized clinical trials will be required to test such strategies before they are widely implemented. Finally, the occurrence of TACO ought to be considered as a potentially avoidable medical complication that could be used to benchmark transfusion and critical care practice across hospitals. Keywords: blood transfusion, pulmonary edema, risk

  20. The numeracy test workbook everything you need for a successful programme of self study including quick tests and full-length realistic mock-ups

    CERN Document Server

    Bryon, Mike

    2011-01-01

    One of the most common types of psychometric test used in assessment and selection procedures, The Numeracy Test Workbook provides practice questions and mock tests designed to build confidence and improve performance.

  1. The ‘abdominal circulatory pump’: an auxiliary heart during exercise?

    Directory of Open Access Journals (Sweden)

    Barbara eUva

    2016-01-01

    Full Text Available Apart from its role as a flow generator for ventilation the diaphragm has a circulatory role. The cyclical abdominal pressure variations from its contractions cause swings in venous return from the splanchnic venous circulation. During exercise the action of the abdominal muscles may enhance this circulatory function of the diaphragm. Eleven healthy subjects (25±7yr, 70±11kg, 1.78±0.1m, 3F performed plantar flexion exercise at ∼4 METs. Changes in body volume (ΔVb and trunk volume (ΔVtr were measured simultaneously by double body plethysmography. Volume of blood shifts between trunk and extremities (Vbs was determined non-invasively as ΔVtr-ΔVb. Three types of breathing were studied: spontaneous (SE, rib cage (RCE, voluntary emphasized inspiratory rib cage breathing and abdominal (ABE, voluntary active abdominal expiration breathing.. During SE and RCE blood was displaced from the extremities into the trunk (on average 0.16± 0.33L and 0.48±0.55L, p<0.05 SE vs RCE, while during ABE it was displaced from the trunk to the extremities (0.22±0.20L p<0.001, p<0.05 RCE and SE vs ABE respectively. At baseline, Vbs swings (maximum to minimum amplitude were bimodal and averaged 0.13±0.08L. During exercise, Vbs swings consistently increased (0.42±0.34L, 0.40±0.26L, 0.46±0.21L, for SE, RCE and ABE respectively, all p<0.01 vs. baseline. It follows that during leg exercise significant bi-directional blood shifting occurs between the trunk and the extremities. The dynamics and partitioning of these blood shifts strongly depend on the relative predominance of the action of the diaphragm, the rib cage and the abdominal muscles. Depending on the partitioning between respiratory muscles for the act of breathing, the distribution of blood between trunk and extremities can vary by up to 1 L. We conclude that during exercise the abdominal muscles and the diaphragm might play a role of an ‘auxiliary heart’.

  2. Detecting white dwarf binaries in Mock LISA Data Challenge 3

    International Nuclear Information System (INIS)

    Blaut, A; Krolak, A; Babak, S

    2009-01-01

    We present a strategy for detecting gravitational wave signals from the Galactic white dwarf binaries in the Mock LISA Data Challenge 3 (MLDC3) and estimate their parameters. Our method is based on the matched filtering in the form of the F-statistic. We perform the search on three-dimensional space (sky coordinate and frequency of gravitational wave) below 3 mHz and include the fourth parameter (frequency derivative) at high frequencies. A template bank is used to search for the strongest signal in the data, then we remove it and repeat the search until we do not have signals in the data above a preselected threshold. For the template bank, we construct an optimal grid that realizes the best lattice covering with a constraint such that the nodes of the grid coincide with the Fourier frequencies. This enables the use of the fast Fourier transform algorithm to calculate the F-statistic.

  3. Performance test results of helium gas circulator of mock-up test facility with full-scale reaction tube for HTTR hydrogen production system. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akira; Kato, Michio; Hayashi, Koji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2003-03-01

    Hydrogen production system by steam reforming of methane will be connected to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) against development of nuclear heat utilization system. To obtain design and safety database of the HTTR hydrogen production system, mock-up test facility with full-scale reaction was constructed in FY 2001 and hydrogen of 120m{sup 3}N{sub /}h was successfully produced in overall performance test. This report describes performance test results of a helium gas circulator in this facility. The circulator performance curves regarding to pressure-rise, input power and adiabatic thermal efficiency at standard revolution number were made based on the measured flow-rate, temperature and pressure data in overall performance test. The circulator performance prediction code was made based on these performance curves. The code can calculate revolution number, electric power and temperature-rise of the circulator using flow-rate, inlet temperature, inlet pressure and pressure-rise data. The verification of the code was carried out with the test data in FY 2002. Total pressure loss of the helium gas circulation loop was also evaluated. The circulator should be operated in conditions such as pressure from 2.7MPa to 4.0MPa and flow-rate from 250g/s to 400g/s and at maximum pressure-rise of 250 kPa in test operation. It was confirmed in above verification and evaluations that the circulator had performance to satisfy above conditions within operation limitation of the circulator such as maximum input-power of 150 kW and maximum revolution number of 12,000 rpm. (author)

  4. Mortality from Circulatory System Diseases among French Uranium Miners: A Nested Case-Control Study.

    Science.gov (United States)

    Drubay, Damien; Caër-Lorho, Sylvaine; Laroche, Pierre; Laurier, Dominique; Rage, Estelle

    2015-05-01

    A significant association has been observed between radon exposure and cerebrovascular disease (CeVD) mortality among French uranium miners, but risk factors for circulatory system diseases (CSD) have not been previously considered. We conducted new analyses in the recently updated (through 2007) French cohort of uranium miners (n = 5,086), which included 442 deaths from CSD, 167 of them from ischemic heart disease (IHD) and 105 from CeVD. A nested case-control study was then set up to collect and investigate the influence of these risk factors on the relationships between mortality from CSD and occupational external gamma ray and internal ionizing radiation exposure (radon and long-lived radionuclides) in this updated cohort. The nested case-control study included miners first employed after 1955, still employed in 1976 and followed up through 2007. Individual information about CSD risk factors was collected from medical files for the 76 deaths from CSD (including 26 from IHD and 16 from CeVD) and 237 miners who had not died of CSD by the end of follow-up. The exposure-risk relationships were assessed with a Cox proportional hazard model weighted by the inverse sampling probability. A significant increase in all CSD and CeVD mortality risks associated with radon exposure was observed in the total cohort [hazard ratios: HRCSD/100 working level months (WLM) = 1.11, 95% confidence interval (1.01; 1.22) and HRCeVD/100 WLM = 1.25 (1.09; 1.43), respectively]. A nonsignificant exposure-risk relationship was observed for every type of cumulative ionizing radiation exposure and every end point [e.g., HRCSD/100WLM = 1.43 (0.71; 2.87)]. The adjustment for each CSD risk factor did not substantially change the exposure-risk relationships. When the model was adjusted for overweight, hypertension, diabetes, hypercholesterolemia and smoking status, the HR/100WLM for CSD, for example, was equal to 1.21 (0.54; 2.75); and when it was adjusted for risk factors selected with the

  5. Use of nuclear data sensitivity and uncertainty analysis for the design preparation of the HCLL breeder blanket mock-up experiment for ITER

    International Nuclear Information System (INIS)

    Kodeli, I.

    2007-01-01

    An experiment on a mock-up of the Test Blanket module based on Helium Cooled Lithium Lead (HCLL) concept will be performed in 2007 in the FNG utility in Frascati in order to study neutronics characteristics of the module and the performance of the computational tools in the accurate prediction of the neutron transport. With the objective to prepare and optimise the design of the mock-up in the sense to provide maximum information on the state-of-the-art of the cross section data the mock-up was pre-analysed using the deterministic codes for the sensitivity/uncertainty analysis. The neutron fluxes and tritium production rate (TPR), their sensitivity to the underlying basic cross sections, as well as the corresponding uncertainty estimations were calculated using the deterministic transport codes (DOORS package), the sensitivity/uncertainty code package SUSD3D and the VITAMIN-J/COVA covariance matrix libraries. The cross section reactions with largest contribution to the uncertainty in the calculation of the TPR were identified to be (n,2n) and (n,3n) reactions on plumb. The conclusions of this work support the main benchmark design and suggest some modifications and improvements. In particular this study recommends the use, as far as possible, of both natural and enriched lithium pellets for the TRP measurements. The combined use is expected to provide additional and complementary information on the sensitive cross sections. (author)

  6. Factors influencing the outcome of paediatric cardiac surgical patients during extracorporeal circulatory support

    Directory of Open Access Journals (Sweden)

    Peek Giles J

    2007-01-01

    Full Text Available Abstract Background Veno-arterial extracorporeal membrane oxygenation (ECMO is a common modality of circulatory assist device used in children. We assessed the outcome of children who had ECMO following repair of congenital cardiac defects (CCD and identified the risk factors associated with hospital mortality. Methods From April 1990 to December 2003, 53 patients required ECMO following surgical correction of CCD. Retrospectively collected data was analyzed with univariate and multivariate logistic regression analysis. Results Median age and weight of the patients were 150 days and 5.4 kgs respectively. The indications for ECMO were low cardiac output in 16, failure to wean cardiopulmonary bypass in 13, cardiac arrest in 10 and cardio-respiratory failure in 14 patients. The mean duration of ECMO was 143 hours. Weaning off from ECMO was successful in 66% and of these 83% were survival to hospital-discharge. 37.7% of patients were alive for the mean follow-up period of 75 months. On univariate analysis, arrhythmias, ECMO duration >168 hours, bleeding complications, renal replacement therapy on ECMO, arrhythmias and cardiac arrest after ECMO were associated with hospital mortality. On multivariate analysis, abnormal neurology, bleeding complications and arrhythmias after ECMO were associated with hospital mortality. Extra and intra-thoracic cannulations were used in 79% and 21% of patients respectively and extra-thoracic cannulation had significantly less bleeding complications (p = 0.031. Conclusion ECMO provides an effective circulatory support following surgical repair of CCD in children. Extra-thoracic cannulation is associated with less bleeding complications. Abnormal neurology, bleeding complications on ECMO and arrhythmias after ECMO are poor prognostic indicators for hospital survival.

  7. Utilization of organs from donors after circulatory death for vascularized pancreas and islet of Langerhans transplantation : recommendations from an expert group

    NARCIS (Netherlands)

    Berney, Thierry; Boffa, Catherine; Augustine, Titus; Badet, Lionel; de Koning, Eelco; Pratschke, Johann; Socci, Carlo; Friend, Peter

    2015-01-01

    Donation after circulatory death (DCD) donors are increasingly being used as a source of pancreas allografts for vascularized organ and islet transplantation. We provide practice guidelines aiming to increase DCD pancreas utilization. We review risk assessment and donor selection criteria. We report

  8. Effective use of plant simulators and mock-up facilities for cultivation and training of younger regulators

    International Nuclear Information System (INIS)

    Tsuruga, Keisuke

    2010-01-01

    In order to achieve effective safety regulation, the staff members of a regulatory body who are engaged in regulatory work are requested to be well familiar with the characteristics, operations and maintenances of nuclear power plants at a practical level as far as possible. Although the regulators are not always required to have the same level of skills as those of plant designers or operators, the skills of the regulatory staff are essential elements to achieve high quality of the national nuclear safety regulation. Especially understanding of fundamentals such as operations, transient behaviors, trouble responses and plant inspections is indispensable not only to practical regulatory work but also to the establishment of the trust and confidence in safety regulation. To acquire these skills, the use of facilities such as plant simulators and inspection mock-up facilities is very effective to back up classroom lectures on theories and procedures. Practical training using these facilities under the guidance of well-experienced instructors inspires motivations and enhances capabilities of younger regulators. To support the countries newly embarking on nuclear power programs, JNES will continue to cooperate with those countries in cultivating and training younger regulators, by focusing on the training by veteran instructors using full-scale plant simulators and inspection mock-up facilities to give the trainees more practical skills and knowledge difficult to obtain through classroom lectures or textbooks. (author)

  9. Preliminary minimum detectable limit measurements in 208-L drums for selected actinide isotopes in mock-waste matrices

    International Nuclear Information System (INIS)

    Camp, D.C.; Wang, Tzu-Fang; Martz, H.E.

    1992-01-01

    Preliminary minimum detectable levels (MDLS) of selected actinide isotopes have been determined in full-scale, 55-gallon drums filled with a range of mock-waste materials from combustibles (0.14 g/CM 3 ) to sand (1.7 g/CM 3 ). Measurements were recorded from 100 to 10,000 seconds with selected actinide sources located in these drums at an edge position, on the center axis of a drum and midway between these two positions. Measurements were also made with a 166 Ho source to evaluate the attenuation of these mock-matrix materials as a function of energy. By knowing where the source activity is located within a drum, our preliminary results show that a simply collimated 90% HPGE detector can differentiate between TRU (>100 nCi/g) and LLW amounts of 239 Pu in only 100s of measurement time and with sufficient accuracy in both low and medium density, low Z materials. Other actinides measured so far include 235 U, 241 Am, and 244 Cm. These measurements begin to establish the probable MDLs achievable in the nondestructive assays of real waste drums when using active and passive CT. How future measurements may differ from these preliminary measurements is also discussed

  10. Transplantation of Hearts Donated after Circulatory Death

    Directory of Open Access Journals (Sweden)

    Christopher W. White

    2018-02-01

    Full Text Available Cardiac transplantation has become limited by a critical shortage of suitable organs from brain-dead donors. Reports describing the successful clinical transplantation of hearts donated after circulatory death (DCD have recently emerged. Hearts from DCD donors suffer significant ischemic injury prior to organ procurement; therefore, the traditional approach to the transplantation of hearts from brain-dead donors is not applicable to the DCD context. Advances in our understanding of ischemic post-conditioning have facilitated the development of DCD heart resuscitation strategies that can be used to minimize ischemia-reperfusion injury at the time of organ procurement. The availability of a clinically approved ex situ heart perfusion device now allows DCD heart preservation in a normothermic beating state and minimizes exposure to incremental cold ischemia. This technology also facilitates assessments of organ viability to be undertaken prior to transplantation, thereby minimizing the risk of primary graft dysfunction. The application of a tailored approach to DCD heart transplantation that focuses on organ resuscitation at the time of procurement, ex situ preservation, and pre-transplant assessments of organ viability has facilitated the successful clinical application of DCD heart transplantation. The transplantation of hearts from DCD donors is now a clinical reality. Investigating ways to optimize the resuscitation, preservation, evaluation, and long-term outcomes is vital to ensure a broader application of DCD heart transplantation in the future.

  11. The effects of aprotinin on blood product transfusion associated with thoracic aortic surgery requiring deep hypothermic circulatory arrest.

    LENUS (Irish Health Repository)

    Seigne, P W

    2012-02-03

    OBJECTIVE: To compare the effects of aprotinin on blood product use and postoperative complications in patients undergoing thoracic aortic surgery requiring deep hypothermic circulatory arrest. DESIGN: A retrospective study. SETTING: A university hospital. PARTICIPANTS: Nineteen patients who underwent elective or urgent thoracic aortic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The total number of units of packed red blood cells, fresh frozen plasma, and platelets was significantly less in the group that received aprotinin (p = 0.01, 0.04, and 0.01). The intraoperative transfusion of packed red blood cells and platelets, collection and retransfusion of cell saver, and postoperative transfusion of fresh frozen plasma were also significantly less in the aprotinin group (p = 0.01, 0.02, 0.01, and 0.05). No patient in either group sustained renal dysfunction or a myocardial infarction. Two patients who had not received aprotinin suffered from chronic postoperative seizures, and one patient who had received aprotinin sustained a perioperative stroke. CONCLUSIONS: Low-dose aprotinin administration significantly decreases blood product transfusion requirements in the setting of thoracic aortic surgery requiring deep hypothermic circulatory arrest, and it does not appear to be associated with renal or myocardial dysfunction.

  12. A Multicenter Study on Long-Term Outcomes After Lung Transplantation Comparing Donation After Circulatory Death and Donation After Brain Death

    NARCIS (Netherlands)

    van Suylen, Vincent; Luijk, B.; Hoek, R A S; van de Graaf, E. A.; Verschuuren, E A; Van De Wauwer, C; Bekkers, J A; Meijer, R C A; van der Bij, W; Erasmus, M E

    2017-01-01

    The implementation of donation after circulatory death category 3 (DCD3) was one of the attempts to reduce the gap between supply and demand of donor lungs. In the Netherlands, the total number of potential lung donors was greatly increased by the availability of DCD3 lungs in addition to the

  13. Design and Analysis of the Korean Small Semi-prototype Mock-up for the 2nd Qualification of the ITER Blanket First Wall

    International Nuclear Information System (INIS)

    Lee, Dong Won; Kim, Suk Kwon; Yoon, Jae Sung; Lee, Eo Hwak; Lee, Seung Jae; Choi, Bo Guen; Park, Jeong Yong; Jung, Yang Il; Choi, Byung Kwon; Kim, Byoung Yoon

    2011-01-01

    Since the blanket First Wall (FW) of the International Thermonuclear Experimental Reactor (ITER) is subjected to a high heat and high neutron loads, it is one of the most important components. It composed of a beryllium (Be) layer as a plasma facing material, a copper alloy (CuCrZr) layer as a heat sink and type 316L authentic stainless steel (SS316L) as a structure material. The joining of the three different metals is the key issue to be solved. And more, the peak heat load was assumed to be 0.5 MW/m 2 in the initial design of the FW, but it was changed to be up to 5 MW/m 2 In Korea, the joining method has developed and it was proved through the several mock-up fabrication and high heat flux tests for confirming the joining integrity. Some of them were tested in the foreign facilities such as JEBIS at JAEA in Japan, TSEFEY at Efremov in Russia, and JUDITH at FZJ in Germany, and others were tested in our own facilities such as KoHLT-1 and -2. And finally, the 1 st , recently. Therefore, the FW panel design has been changed for enhancing the cooling and ITER Organization will provide the proposed design. Qualification was passed, in which two 80x80x3 Be/Cu/SS mock-ups were tested under 0.625 and 0.875 MW/m 2 heat fluxes for 12,000 cycles and then tested under 1.75 and 1.40 MW/m 2 Currently, the 2 heat fluxes for 1,000 cycles at FZJ and SNL, respectively. Currently, the 2 nd qualification program was started and the semi-prototype should be fabricated by the end of 2011 for testing under 5.0 MW/m 2 heat flux for certain number of cycles. In order to prepare the semi-prototype, several fabrication methods should be developed through the fabrication and test with the several mock-ups. In the present study, small Be mock-up was fabricated as the first step for the preparation. It was fabricated according to the designs considering the currently modified design of the FW. In the present paper, the fabrication objectives, methods, results and related tests were

  14. Astragalus Extract Mixture HT042 Increases Longitudinal Bone Growth Rate by Upregulating Circulatory IGF-1 in Rats

    Directory of Open Access Journals (Sweden)

    Donghun Lee

    2017-01-01

    Full Text Available Astragalus extract mixture HT042 is a standardized ingredient of health functional food approved by Korean FDA with a claim of “height growth of children.” HT042 stimulates bone growth rate and increases local IGF-1 expression in growth plate of rats which can be considered as direct stimulation of GH and its paracrine/autocrine actions. However, it remains unclear whether HT042 stimulates circulatory IGF-1 which also plays a major role to stimulate bone growth. To determine the effects on circulatory IGF-1, IGF-1 and IGFBP-3 expressions and phosphorylation of JAK2/STAT5 were evaluated in the liver after 10 days of HT042 administration. HT042 upregulated liver IGF-1 and IGFBP-3 mRNA expression, IGF-1 protein expression, and phosphorylation of JAK2/STAT5. HT042 also increased bone growth rate and proliferative zonal height in growth plate. In conclusion, HT042 stimulates bone growth rate via increment of proliferative rate by upregulation of liver IGF-1 and IGFBP-3 mRNA followed by IGF-1 protein expression through phosphorylation of JAK2/STAT5, which can be regarded as normal functioning of GH-dependent endocrine pathway.

  15. Evaluation of cerebro-circulatory metabolic conditions and prognosis in hypertensive putaminal hemorrhage by 31P-MRS

    International Nuclear Information System (INIS)

    Deguchi, Itaru

    2000-01-01

    Phosphorus-31 nuclear magnetic resonance spectroscopy ( 31 P-MRS) provides a non-invasive means to obtain metabolic information. We studied cerebro-circulatory metabolic conditions in the subacute phase of hypertensive putaminal hemorrhage with 31 P-MRS and N-isopropyl-I-(123)-p-Iodoamphetamine single photon emission computed tomography ( 123 I-IMP SPECT). The subjects consisted of 33 cases of hypertensive putaminal hemorrhage. Upon evaluation of cerebral blood flow (CBF) around the ipsilateral frontal lobe cortex and examination by 123 I-IMP SPECT, they would broadly divided into the following three groups: (A) a group with high uptake on both the early image and delayed image, (B) a group with low uptake on the early image but with good redistribution, and (C) a group with low uptake on both images. In these groups 31 P-MRS in the ipsilateral frontal lobe cortex was measured for comparative analysis. In group A, the PCr/Pi ratio was 3.12±0.14 as opposed to 2.87±0.13 in group B, and the ratio was extremely depressed in group C, 1.96±0.16. These observations implied that a high level circulatory metabolic disorder was present in group C and that local viability or metabolic activity was relatively well maintained despite the low perfusion in group B with a satisfactory prognosis being expected due to their high functional level. (author)

  16. Development of an Analysis Pipeline Characterizing Multiple Hypervariable Regions of 16S rRNA Using Mock Samples.

    Directory of Open Access Journals (Sweden)

    Jennifer J Barb

    Full Text Available There is much speculation on which hypervariable region provides the highest bacterial specificity in 16S rRNA sequencing. The optimum solution to prevent bias and to obtain a comprehensive view of complex bacterial communities would be to sequence the entire 16S rRNA gene; however, this is not possible with second generation standard library design and short-read next-generation sequencing technology.This paper examines a new process using seven hypervariable or V regions of the 16S rRNA (six amplicons: V2, V3, V4, V6-7, V8, and V9 processed simultaneously on the Ion Torrent Personal Genome Machine (Life Technologies, Grand Island, NY. Four mock samples were amplified using the 16S Ion Metagenomics Kit™ (Life Technologies and their sequencing data is subjected to a novel analytical pipeline.Results are presented at family and genus level. The Kullback-Leibler divergence (DKL, a measure of the departure of the computed from the nominal bacterial distribution in the mock samples, was used to infer which region performed best at the family and genus levels. Three different hypervariable regions, V2, V4, and V6-7, produced the lowest divergence compared to the known mock sample. The V9 region gave the highest (worst average DKL while the V4 gave the lowest (best average DKL. In addition to having a high DKL, the V9 region in both the forward and reverse directions performed the worst finding only 17% and 53% of the known family level and 12% and 47% of the genus level bacteria, while results from the forward and reverse V4 region identified all 17 family level bacteria.The results of our analysis have shown that our sequencing methods using 6 hypervariable regions of the 16S rRNA and subsequent analysis is valid. This method also allowed for the assessment of how well each of the variable regions might perform simultaneously. Our findings will provide the basis for future work intended to assess microbial abundance at different time points

  17. Comparing three methods for participatory simulation of hospital work systems

    DEFF Research Database (Denmark)

    Broberg, Ole; Andersen, Simone Nyholm

    Summative Statement: This study compared three participatory simulation methods using different simulation objects: Low resolution table-top setup using Lego figures, full scale mock-ups, and blueprints using Lego figures. It was concluded the three objects by differences in fidelity and affordance...... scenarios using the objects. Results: Full scale mock-ups significantly addressed the local space and technology/tool elements of a work system. In contrast, the table-top simulation object addressed the organizational issues of the future work system. The blueprint based simulation addressed...

  18. A review of non-cancer effects, especially circulatory and ocular diseases

    Energy Technology Data Exchange (ETDEWEB)

    Little, Mark P. [National Cancer Institute, Radiation Epidemiology Branch, Bethesda, MD (United States)

    2013-11-15

    There is a well-established association between high doses (>5 Gy) of ionizing radiation exposure and damage to the heart and coronary arteries, although only recently have studies with high-quality individual dosimetry been conducted that would enable quantification of this risk adjusting for concomitant chemotherapy. The association between lower dose exposures and late occurring circulatory disease has only recently begun to emerge in the Japanese atomic bomb survivors and in various occupationally exposed cohorts and is still controversial. Excess relative risks per unit dose in moderate- and low-dose epidemiological studies are somewhat variable, possibly a result of confounding and effect modification by well-known (but unobserved) risk factors. Radiation doses of 1 Gy or more are associated with increased risk of posterior subcapsular cataract. Accumulating evidence from the Japanese atomic bomb survivors, Chernobyl liquidators, US astronauts, and various other exposed groups suggests that cortical cataracts may also be associated with ionizing radiation, although there is little evidence that nuclear cataracts are radiogenic. The dose-response appears to be linear, although modest thresholds (of no more than about 0.6 Gy) cannot be ruled out. A variety of other non-malignant effects have been observed after moderate/low-dose exposure in various groups, in particular respiratory and digestive disease and central nervous system (and in particular neuro-cognitive) damage. However, because these are generally only observed in isolated groups, or because the evidence is excessively heterogeneous, these associations must be treated with caution. (orig.)

  19. Experiment and analysis of hypervapotron mock-ups for preparing the 2nd qualification of the ITER blanket first wall

    International Nuclear Information System (INIS)

    Lee, Dong Won; Bae, Young Dug; Kim, Suk Kwon; Bang, In Cheol

    2010-01-01

    According to the increased heat flux condition up to 5 MW/m 2 in the International Thermonuclear Experimental Reactor (ITER), new design of the blanket first wall (FW) has been considered and the analysis was performed with ANSYS-CFX for checking its temperature with the ITER operation conditions. And a semi-prototype of the FW was proposed to be tested with the similar heat flux conditions under the second qualification for the FW procurement. In order to investigate the fabrication procedure and analysis capability of the code, two types of mock-up were fabricated according to the current semi-prototype design except for bending shape; one with hypervapotron and another without it. They were tested with KoHLT-2 (Korea Heat Load Test) facility and the results were compared with the ones by CFX code. The mass flow rate of inlet coolant was the same as the ITER condition and heat flux was loaded up to 0.48 MW/m 2 heat flux. The results show that the temperature of the mock-up can be predicted using the CFX code even with the complex geometry and the hypervapotron shows its function to increase the cooling.

  20. One Country, Two Cultures: Are Hong Kong Mock Jurors "Mainlandized" by the Predominant Chinese Criminal Justice Concept of Confession?

    Science.gov (United States)

    Hui, Cora Y T; Lo, T Wing

    2015-09-01

    Over-reliance on confession has had a long history in the Chinese criminal justice system. Recent high-profile wrongful conviction cases have raised public awareness of the coercive and torturous methods used to extract confessions. Despite the return of Hong Kong to Chinese sovereignty, Hong Kong remains a common law jurisdiction and the most serious criminal offences are tried by a jury. The present study empirically examines the relative impact of DNA evidence, confession, eyewitness testimony, and victim testimony in a Hong Kong-Chinese mock juror sample. The results show that the participants placed greater value on DNA evidence than on confession, and placed the lowest value on testimonial evidence. It is argued that the situation of "one country, two cultures" remains strong: Whereas participants are still influenced by the Chinese criminal justice concept of confession, their judgment is still predominately influenced by the scientific evidence as commonly practiced in the West. Thus, no solid evidence has been found to confirm the emergence of mainlandization in Hong Kong's criminal justice system. © The Author(s) 2014.

  1. Dismantling Experiment of Mock-up Tube Bundle of Steam Generator

    International Nuclear Information System (INIS)

    Kim, Sung Kyun; Lee, Kune Woo

    2010-01-01

    A SG (steam generator) is one of the biggest decommissioning components in nuclear power plants and one has been replaced 2∼6 times during the whole operation of a nuclear power plant. The old SG should be decommissioned for the purpose of the volume reduction of radioactive waste. Among the components of SG, the tube bundle is one of the most difficult items to be dismantled due to the fact that it is very hard to cut since it is made of Inconel 600 which has high resistance of corrosion and abrasion. Moreover, All cutting process should be performed by remotely since radioactive contamination of the internal surface of SG tubes is very high (about 150,000∼300,000 Bq/cm 2 ). Therefore, it is necessary to choose the appropriate cutting methods by the pros and cons analysis for candidate dismantling technologies and to do experiment study for the validation. In this study, the results of cutting experiment for a mock-up bundle by using band saw cutting method are described herein

  2. Progress on pebble bed experimental activity for the HE-FUS3 mock-ups

    International Nuclear Information System (INIS)

    Dell'Orco, G.; Sansone, L.; Simoncini, M.; Zito, D.

    2002-01-01

    The EU Long Term for DEMO Programme foresees the qualification of the reference design of the helium cooled pebble bed (HCPB) - test blanket module (TBM) to be tested in ITER Reactor. In this frame, FZK and ENEA have launched many experimental activities for the evaluation of the interactions between the Tritium breeder and neutron multiplier pebble beds and the steel containment walls. Main aim of these activities is the measuring the pebble bed effective thermal conductivity, the wall heat transfer coefficient as well as their dependency from the mechanical constraints. The paper presents the progress of the testing activity and results of the tests on two mock-up, called Tazza and Helichetta, carried out on the HE-FUS3 facility at ENEA Brasimone. (orig.)

  3. Acute resistance exercise modulates microRNA expression profiles: Combined tissue and circulatory targeted analyses.

    Directory of Open Access Journals (Sweden)

    Randall F D'Souza

    Full Text Available A subset of short non-coding RNAs, microRNAs (miRs, have been identified in the regulation of skeletal muscle hypertrophy and atrophy. Expressed within cells, miRs are also present in circulation (c-miR and have a putative role in cross-tissue signalling. The aim of this study was to examine the impact of a single bout of high intensity resistance exercise (RE on skeletal muscle and circulatory miRs harvested simultaneously. Resistance trained males (n = 9, 24.6 ± 4.9 years undertook a single bout of high volume RE with venous blood and muscle biopsies collected before, 2 and 4hr post-exercise. Real time polymerase chain reaction (Rt-PCR analyses was performed on 30 miRs that have previously been shown to be required for skeletal muscle function. Of these, 6 miRs were significantly altered within muscle following exercise; miR-23a, -133a, -146a, -206, -378b and 486. Analysis of these same miRs in circulation demonstrated minimal alterations with exercise, although c-miR-133a (~4 fold, p = 0.049 and c-miR-149 (~2.4 fold; p = 0.006 were increased 4hr post-exercise. Thus a single bout of RE results in the increased abundance of a subset of miRs within the skeletal muscle, which was not evident in plasma. The lack a qualitative agreement in the response pattern of intramuscular and circulating miR expression suggests the analysis of circulatory miRs is not reflective of the miR responses within skeletal muscle after exercise.

  4. Report on the first round of the Mock LISA Data Challenges

    International Nuclear Information System (INIS)

    Arnaud, K A; Auger, G; Babak, S

    2007-01-01

    The Mock LISA Data Challenges (MLDCs) have the dual purpose of fostering the development of LISA data analysis tools and capabilities, and demonstrating the technical readiness already achieved by the gravitational-wave community in distilling a rich science payoff from the LISA data output. The first round of MLDCs has just been completed: nine challenges consisting of data sets containing simulated gravitational-wave signals produced either by galactic binaries or massive black hole binaries embedded in simulated LISA instrumental noise were released in June 2006 with deadline for submission of results at the beginning of December 2006. Ten groups have participated in this first round of challenges. All of the challenges had at least one entry which successfully characterized the signal to better than 95% when assessed via a correlation with phasing ambiguities accounted for. Here, we describe the challenges, summarize the results and provide a first critical assessment of the entries

  5. Fabrication of mock-up with Be armour tiles diffusion bonded to the CuCrZr heat sink

    International Nuclear Information System (INIS)

    Moreschi, L.F.; Pizzuto, A.; Alessandrini, I.; Agostini, M.; Visca, E.; Merola, M.

    2001-01-01

    The aim of this work is the manufacture of high heat flux mock-ups with Be armour tiles on a CuCrZr heat sink for fabricating the beryllium section of the divertor vertical target (DVT) in the ITER reactor. Diffusion bonding between the CuCrZr bar and the beryllium tiles was obtained by inserting an aluminium interlayer to accommodate surface irregularities as well as to provide a compliant layer for accommodating thermal mismatches during both manufacturing and operation and cycles

  6. Fluoro jade-C staining in the assessment of brain injury after deep hypothermia circulatory arrest.

    Science.gov (United States)

    Wang, Ren; Ma, Wei-Guo; Gao, Guo-Dong; Mao, Qun-Xia; Zheng, Jun; Sun, Li-Zhong; Liu, Ying-Long

    2011-02-04

    To evaluate the efficacy of Fluoro Jade-C staining (FJC) in the assessment of brain injury after deep hypothermia circulatory arrest (DHCA). Six healthy adult miniature male pigs underwent DHCA, the rectal temperature was down to 18°C, circulation was stopped , circulatory arrest was maintained for 60 minutes. On postoperative day 1, perfusion-fixation was performed on brain tissue. Cerebral cortex, hippocampus, cerebellum were taken for sampling. FJC, hematoxylin-eosin staining (HE), nissl staining (NISSL), terminal deoxynucleotidyl transferase biotin-dUTP nick end labeling (TUNEL) were performed to detect the histological and pathological changes. Histological scores of all slices were ranked. Comparison between the FJC and other techniques was done by analysis of variance (ANOVA) according to histological scores. All animals survived the operation. On the cerebral cortex, in comparison of FJC between HE, NISSL and TUNEL, the p value was 0.90, 0.40, 0.16 respectively (p>0.05). On the hippocampus, the comparison of FJC with HE, NISSL and TUNEL had a p value of 0.12, 0.23, 0.62 respectively (p>0.05). On the cerebellum, in comparing FJC with HE, NISSL and TUNEL, the p value was 0.96, 0.77, 0.96 respectively (p>0.05). On representative regions, the results of FJC were in accordance with that of TUNEL, NISSL and HE. Furthermore, ascertainment of brain injury is easier with FJC. FJC is a reliable and convenient method to assess brain injury after DHCA. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    International Nuclear Information System (INIS)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-01-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): Electrical Resistivity Tomography (ERT); Cross-Borehole Electromagnetic Induction (CEMI) ; High-Resolution Resistivity (HRR); Cross-Borehole Radar (XBR); Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone

  8. Intracorporeal Heat Distribution from Fully Implantable Energy Sources for Mechanical Circulatory Support: A Computational Proof-of-Concept Study

    OpenAIRE

    Biasetti, Jacopo; Pustavoitau, Aliaksei; Spazzini, Pier Giorgio

    2017-01-01

    Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into ...

  9. Comparison between FEM and high heat flux thermal fatigue testing results of ITER divertor plasma facing mock-ups

    Energy Technology Data Exchange (ETDEWEB)

    Crescenzi, F., E-mail: fabio.crescenzi@enea.it; Roccella, S.; Visca, E.; Moriani, A.

    2014-10-15

    Highlights: • Divertor is an important part of the ITER machine. • Finite element analysis allows designers to explore multiple design options, reducing physical prototypes and optimizing design performance. • The hydraulic thermal-mechanical analysis performed by ANSYS and the test results on small-scale mock-ups manufactured by HRP were compared. • FEA results confirmed many experimental data, then it could be very useful for next design optimization. - Abstract: The divertor is one of the most challenging components of “DEMO” the next step ITER machine, so many tasks regarding modeling and experiments have been made in the past years to assess manufacturing processes, materials and thus the life-time of the components. In this context the finite element analysis (FEA) allows designers to explore multiple design options, to reduce physical prototypes and to optimize design performance. The comparison between the hydraulic thermal-mechanical analysis performed by ANSYS WORKBENCH 14.5 and the test results [1] on small-scale mock-ups manufactured with the Hot Radial Pressing (HRP) [2] technology is presented in this paper. During the thermal fatigue testing in the Efremov TSEFEY facility to assess the heat flux load-carrying capability of the mock-ups, only the surface temperature was measured, so the FEA was important because it allowed to know any other information (temperature inside the materials, local water temperature, local stress, etc.). FEA was performed coupling the thermal-hydraulic analysis, that calculated the temperature distributions on the components and the heat transfer coefficient (HTC) between water and heat sink tube, with the mechanical analysis. The comparison between analysis and testing results was based on the temperature maps of the loaded surface and on number of the cycles supported during the testing and those predicted by the mechanical analysis using the experimental fatigue curves for CuCrZr-IG, that is the structural

  10. Improved gene amplification by cell-cycle engineering combined with the Cre-loxP system in Chinese hamster ovary cells.

    Science.gov (United States)

    Matsuyama, Rima; Tsutsui, Tomomi; Lee, Kyoung Ho; Onitsuka, Masayoshi; Omasa, Takeshi

    2015-12-01

    The dihydrofolate reductase gene amplification system is widely used in Chinese hamster ovary (CHO) cells for the industrial production of therapeutic proteins. To enhance the efficiency of conventional gene amplification systems, we previously presented a novel method using cell-cycle checkpoint engineering. Here, we constructed high-producing and stable cells by the conditional expression of mutant cell division cycle 25 homolog B (CDC25B) using the Cre-loxP system. A bispecific antibody-producing CHO DG44-derived cell line was transfected with floxed mutant CDC25B. After inducing gene amplification in the presence of 250 nM methotrexate, mutant CDC25B sequence was removed by Cre recombinase protein expression. Overexpression of the floxed mutant CDC25B significantly enhanced the efficiency of transgene amplification and productivity. Moreover, the specific production rate of the isolated clone CHO Cre-1 and Cre-2 were approximately 11-fold and 15-fold higher than that of mock-transfected clone CHO Mock-S. Chromosomal aneuploidy was increased by mutant CDC25B overexpression, but Cre-1 and Cre-2 did not show any changes in chromosome number during long-term cultivation, as is the case with CHO Mock-S. Our results suggest that high-producing and stable cells can be constructed by conditionally controlling a cell-cycle checkpoint integrated in conventional gene amplification systems. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  11. Circulatory adaptation to long-term high altitude exposure in Aymaras and Caucasians.

    Science.gov (United States)

    Stuber, Thomas; Scherrer, Urs

    2010-01-01

    About 30 million people live above 2500 m in the Andean Mountains of South America. Among them are 5.5 million Aymaras, an ethnic group with its own language, living on the altiplano of Bolivia, Peru, and northern Chile at altitudes of up to 4400 m. In this high altitude region traces of human population go back for more than 2000 years with constant evolutionary pressure on its residents for genetic adaptation to high altitude. Aymaras as the assumed direct descendents of the ancient cultures living in this region were the focus of much research interest during the last decades and several distinctive adaptation patterns to life at high altitude have been described in this ethnic group. The aim of this article was to review the physiology and pathophysiology of circulatory adaptation and maladaptation to longtime altitude exposure in Aymaras and Caucasians.

  12. Test Plan for the Demonstration of Geophysical Techniques for Single-Shell Tank Leak Detection at the Hanford Mock Tank Site: Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D. Brent; Gee, Glendon W.; Sweeney, Mark D.

    2001-07-31

    As part of the Leak Detection, Monitoring and Mitigation (LDMM) program conducted by CH2M HILL 105-A during FY 2001. These tests are being conducted to assess the applicability of these methods (Electrical Resistance Tomography [ERT], High Resolution Resistivity [HRR], Cross-Borehole Seismography [XBS], Cross-Borehole Radar [XBR], and Cross-Borehole Electromagnetic Induction [CEMI]) to the detection and measurement of Single Shell Tank (SST) leaks into the vadose zone during planned sluicing operations. The testing in FY 2001 will result in the selection of up to two methods for further testing in FY 2002. In parallel with the geophysical tests, a Partitioning Interwell Tracer Test (PITT) study will be conducted simultaneously at the Mock Tank to assess the effectiveness of this technology in detecting and quantifying tank leaks in the vadose zone. Preparatory and background work using Cone Penetrometer methods (CPT) will be conducted at the Mock Tank site and an adjacent test area to derive soil properties for groundtruthing purposes for all methods.

  13. Ion transport in circulatory and/or septic shock

    International Nuclear Information System (INIS)

    Sayeed, M.M.

    1987-01-01

    This review surveys investigations of membrane ion transport in animals in hemorrhagic, endotoxic, or bacteremic shock. The focus of the review is on ion transport studies in the skeletal muscle and liver. Skeletal muscle Na + -K + transport alterations have been shown during the induction of shock via hemorrhage, endotoxin, or live Gram-negative bacteria in the rodent, canine, and primate species. These alterations include impairment of active cellular K + accumulation, increased permeability to 24 Na + and Cl - , and membrane depolarization. The ion transport alterations in the skeletal muscle are compatible with movement of extracellular fluid into the intracellular compartment. Such fluid movements can potentially lead to decreases in circulating plasma volume and thus to circulatory deficits in shock. Studies in the liver of rats subjected to hemorrhagic or endotoxic shock indicated the failure of electrogenic Na + pump. Although the hepatic cellular membrane permeability to Na + relative to permeability to K + appeared unaltered in hemorrhagic shock, endotoxic shock caused an increase in permeability to Na + . Hepatic cellular 45 Ca + regulation also appeared to be adversely affected during endotoxic shock. Alterations in hepatic Na + -K + transport and Ca + regulation could contribute to impairment in hepatic glucose production during shock. Although mechanisms of altered membrane ion transport during shock states remain unknown, such changes could occur prior to any substantial loss of cellular metabolic energy

  14. Annual report on experimental operations and maintenances of mock-up model test facility with a full-scale reaction tube for HTTR hydrogen production system in 2002 fiscal year (Contract research)

    International Nuclear Information System (INIS)

    Hayashi, Koji; Ohashi, Hirofumi; Inaba, Yoshitomo; Kato, Michio; Aita, Hideki; Morisaki, Norihiro; Takeda, Tetsuaki; Nishihara, Tetsuo; Takada, Shoji; Inagaki, Yoshiyuki

    2006-03-01

    This report describes 2002 fiscal-year experimental test operations of the mock-up test facility with a full-scale reaction tube for the HTTR hydrogen production system. The improvement works were performed in May 2002. The second experimental test operation was performed from June 2002 and the performances of the improved parts were confirmed. Periodic inspections on boiler equipment and high-pressure gas production facilities were performed from end of July 2002. The third experimental test operation was performed, from October 2002, for (a) start-up and shutdown test, (b) process change test, (c) chemical reaction shutdown test and (d) characteristics test on steam reformer. It was confirmed that the changes of helium gas temperature, caused at steam reformer, could be mitigated into the target range by the steam generator. Maintenance works of high-pressure gas production facilities were also performed in February 2003. This report is summarized with the outline and the results of the test, maintenance works and inspections, and operation records in mentioned above. (author)

  15. Effect of Withania Somnifera Root Powder on the Levels of Circulatory Lipid Peroxidation and Liver Marker Enzymes in Chronic Hyperammonemia

    Directory of Open Access Journals (Sweden)

    B. Harikrishnan

    2008-01-01

    Full Text Available Withania somnifera (L Dunal (Solanaceae, commonly called Ashwagandha (Sanskrit is an Ayurvedic Indian medicinal plant, which has been widely used as a home remedy for several ailments. We have investigated the influence of W.somnifera root powder on the levels of circulatory ammonia, urea, lipid peroxidation products such as TBARS (thiobarbituric acid and reactive substances, HP (hydroperoxides and liver marker enzymes such as AST (aspartate transaminase, ALT (alanine transaminase and ALP (alkaline phosphatase, for its hepatoprotective effect in ammonium chloride induced hyperammonemia. Ammonium chloride treated rats showed a significant increase in the levels of circulatory ammonia, urea, AST, ALT, ALP, TBARS and HP. These changes were significantly decreased in rats treated with W.somnifera root powder and ammonium chloride. Our results indicate that W.somnifera offers hepatoprotection by influencing the levels of lipid peroxidation products and liver markers in experimental hyperammonemia and this could be due to (i the presence of alkaloids, withanolids and flavonoids, (ii normalizing the levels of urea and urea related compounds, (iii its free radical scavenging property and (iv its antioxidant property. The exact underlying mechanism is still unclear and further research needed.

  16. Clinical comparison of radionuclide cisternography and computed tomography in CSF circulatory disturbance

    International Nuclear Information System (INIS)

    Tanabe, Masaya; Futatsuki, Minoru; Tanaka, Hiroshi.

    1980-01-01

    Forty-three patients with abnormal cisternograms were classified into (1) NPH, (2) Postmeningitic hydrocephalus, (3) Posttraumatic hydrocephalus, (4) Postoperative hydrocephalus (tumor) (5) Postoperative hydrocephalus (vascular disease), (6) Meningitis, (7) Tumor, (8) Vascular disease, (9) Degenerative disease and (10) Miscellaneous. Cisternography was done by a scinticamera with 111 In-DTPA and all groups were scanned by IInd generation CT scanner. The result of the cisternography was not always compatible with the CT findings. We found a case of anatomically normal but functionally abnormal cisterns and ventricular system. In all classified disorder groups, the cisternography detected functioning cisterns in CSF dynamics but the CT visualized anatomically open cisterns. By the combined use of these two examinations, a local cisternal block was detected. Ten in 20 cases with operated (V-P shunt) hydrocephalus clinically improved. But the result of these techniques, failed to assess the effectiveness of the V-P shunt. V-P shunt was effective in 8 out of 14 cases with persistent ventricular reflux and delayed clearance, and in 9 out of 17 cases with total ventricular dilatation. We concluded that the combined use of the RI cisternography and the computed tomography was better than single examination to detect CSF circulatory disturbance but we were not satisfied with the joint use in the evaluation of the effect of V-P shunt. No adverse reaction was experienced in the 43 patients with 111 In-DTPA. (author)

  17. Clinical comparison of radionuclide cisternography and computed tomography in CSF circulatory disturbance

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, M.; Futatsuki, M. (Tazuke Kofukai Medical Research Inst., Osaka (Japan). Kitano Hospital); Tanaka, H.

    1980-12-01

    Forty-three patients with abnormal cisternograms were classified into (1) NPH, (2) Postmeningitic hydrocephalus, (3) Posttraumatic hydrocephalus, (4) Postoperative hydrocephalus (tumor) (5) Postoperative hydrocephalus (vascular disease), (6) Meningitis, (7) Tumor, (8) Vascular disease, (9) Degenerative disease and (10) Miscellaneous. Cisternography was done by a scinticamera with /sup 111/In-DTPA and all groups were scanned by IInd generation CT scanner. The result of the cisternography was not always compatible with the CT findings. We found a case of anatomically normal but functionally abnormal cisterns and ventricular system. In all classified disorder groups, the cisternography detected functioning cisterns in CSF dynamics but the CT visualized anatomically open cisterns. By the combined use of these two examinations, a local cisternal block was detected. Ten in 20 cases with operated (V-P shunt) hydrocephalus clinically improved. But the result of these techniques, failed to assess the effectiveness of the V-P shunt. V-P shunt was effective in 8 out of 14 cases with persistent ventricular reflux and delayed clearance, and in 9 out of 17 cases with total ventricular dilatation. We concluded that the combined use of the RI cisternography and the computed tomography was better than single examination to detect CSF circulatory disturbance but we were not satisfied with the joint use in the evaluation of the effect of V-P shunt. No adverse reaction was experienced in the 43 patients with /sup 111/In-DTPA.

  18. Investigating the Variables in a Mock Exam Study Session Designed to Improve Student Exam Performance in an Undergraduate Behavior Modification and Therapy Course

    Science.gov (United States)

    Dotson, Wesley H.

    2010-01-01

    The purpose of the present study was to identify components of an optional mock exam review session (e.g. requiring students to write answers, providing students grading keys for questions) responsible for improvements in student performance on application-based short-essay exams in an undergraduate behavior modification course. Both…

  19. SCC behavior of alloy 690 from a CDRM mock-up

    International Nuclear Information System (INIS)

    Lapena, J.; Sol Garcia-Redondo, M. del; Perosanz, F.J.; Saez, A.; Gomez-Briceno, D.; Castelao, C.

    2015-01-01

    Stress corrosion cracking (SCC) response of Alloy 690 when the material has been subjected to nonuniform cold working is of interest to understand the behavior of the weld heat affected zone (HAZ) of Alloy 690 in which localised plastic strain exists due to weld shrinkage. This has a special interest in the case of control-rod-drive mechanisms (CRDM) of vessel head. To simulate these conditions during last years many crack growth rate (CGR) data were obtained in deformed material by cold work (rolling, forging or tensile straining), up to 40% of cold working. However, it is unclear to what extent this simulation procedure reproduces the conditions of the material in a CRDM. A research project is being carried out in order to obtain CGR data in realistic situations existing in operating power plants, by the use of CT specimens extracted from CRDMs. This presentation shows the characterization and some results of crack growth rate data on Alloy 690 TT base metal/HAZ/weld metal using specimens made from a CRDM mock-up. It has been fabricated following the usual procedures used for the RPV head fabrication for the Spanish PWR NPP. (authors)

  20. Fabrication data package for HEDL dosimetry in the ORNL Poolside Facility: LWR Pressure Vessel Mock-up irradiation

    International Nuclear Information System (INIS)

    Lippincott, E.P.; McElroy, W.N.; Kellogg, L.S.; Gold, R.; Guthrie, G.L.; Ruddy, F.H.; Ulseth, J.A.

    1981-09-01

    This document provides a complete description of the HEDL dosimetry inserted in the metallurgical specimen irradiation in the LWR Pressure Vessel Mock-up at the Oak Ridge Reactor Poolside Facility (PSF). This experiment is being conducted under the Nuclear Regulatory Commission sponsored program on Surveillance Dosimetry Improvement. The irradiation started April 1980 with recovery of the 2 x 10 19 (nominal fluence with E > 1 MeV) capsule in September 1980, the 4 x 10 19 surveillance capsule in November 1981 and the pressure vessel and void box capaules about August 1982

  1. Mock-up experiment and analysis for the primary shield of the N.S. MUTSU

    International Nuclear Information System (INIS)

    Miyasaka, S.; Asaoka, T.; Taji, Y.; Ise, T.; Koyama, K.; Tsutsui, T.; Takeuchi, M.; Fuse, T.; Miura, T.; Yamaji, Y.

    1977-01-01

    A series of shielding mock-up experiments was performed at JRR-4, a swimming pool type reactor, of Japan Atomic Energy Research Institute (JAERI) to obtain the necessary experimental data and the sufficiently accurate method of calculation adopted for the modification of the MUTSU primary shield. Analyses for the experiments were carried out by using of the Ssub(n) codes, ANISN and TWOTRAN. The two dimensional calculations were performed with the P 1 -S 8 approximation. The neutron streaming through the annular gap between the pressure vessel and the primary shield has been confirmed to be estimated from the present method of calculation. The agreement between the calculated and the measured values is generally in about a factor of 2 to 4. (orig.) [de

  2. Preparing ITER ICRF: development and analysis of the load resilient matching systems based on antenna mock-up measurements

    International Nuclear Information System (INIS)

    Messiaen, A.; Vervier, M.; Dumortier, P.; Grine, D.; Lamalle, P.U.; Durodie, F.; Koch, R.; Louche, F.; Weynants, R.

    2009-01-01

    The reference design for the ICRF antenna of ITER is constituted by a tight array of 24 straps grouped in eight triplets. The matching network must be load resilient for operation in ELMy discharges and must have antenna spectrum control for heating or current drive operation. The load resilience is based on the use of either hybrid couplers or conjugate-T circuits. However, the mutual coupling between the triplets at the low expected loading strongly counteracts the load resilience and the spectrum control. Using a mock-up of the ITER antenna array with adjustable water load matching solutions are designed. These solutions are derived from transmission line modelling based on the measured scattering matrix and are finally tested. We show that the array current spectrum can be controlled by the anti-node voltage distribution and that suitable decoupler circuits can not only neutralize the adverse mutual coupling effects but also monitor this anti-node voltage distribution. A matching solution using four 3 dB hybrids and the antenna current spectrum feedback control by the decouplers provides outstanding performance if each pair of poloidal triplets undergoes a same load variation. Finally, it is verified by modelling that this matching scenario has the same antenna spectrum and load resilience performances as the antenna array loaded by plasma as described by the TOPICA simulation. This is true for any phasing and frequency in the ITER frequency band. The conjugate-T solution is presently considered as a back-up option.

  3. A systematic review and meta-analysis of the circulatory, erythrocellular and CSF selenium levels in Alzheimer's disease: A metal meta-analysis (AMMA study-I).

    Science.gov (United States)

    Reddy, Varikasuvu Seshadri; Bukke, Suman; Dutt, Naveen; Rana, Puneet; Pandey, Arun Kumar

    2017-07-01

    Available studies in the literature on the selenium levels in Alzheimer's disease (AD) are inconsistent with some studies reporting its decrease in the circulation, while others reported an increase or no change as compared to controls. The objective of this study was to perform a meta-analysis of circulatory (plasma/serum and blood), erythrocyte and cerebrospinal fluid (CSF) selenium levels in AD compared controls. We also performed a meta-analysis of the correlation coefficients (r) to demonstrate the associations between selenium and glutathione peroxidase (GPx) in AD patients. All major databases were searched for eligible studies. We included 12 case-control/observational studies reporting selenium concentrations in AD and controls. Pooled-overall effect size as standardized mean difference (SMD) and pooled r-values were generated using Review Manager 5.3 and MedCalc 15.8 software. Random-effects meta-analysis indicated a decrease in circulatory (SMD=-0.44), erythrocellular (SMD=-0.52) and CSF (SMD=-0.14) selenium levels in AD patients compared to controls. Stratified meta-analysis demonstrated that the selenium levels were decreased in both the subgroups with (SMD=-0.55) and without (SMD=-0.37) age matching between AD and controls. Our results also demonstrated a direct association between decreased selenium levels and GPx in AD. This meta-analysis suggests that circulatory selenium concentration is significantly lower in AD patients compared to controls and this decrease in selenium is directly correlated with an important antioxidant enzyme, the GPx, in AD. Copyright © 2017 Elsevier GmbH. All rights reserved.

  4. A novel combination technique of cold crystalloid perfusion but not cold storage facilitates transplantation of canine hearts donated after circulatory death.

    Science.gov (United States)

    Rosenfeldt, Franklin; Ou, Ruchong; Salamonsen, Robert; Marasco, Silvana; Zimmet, Adam; Byrne, Joshua; Cosic, Filip; Saxena, Pankaj; Esmore, Donald

    2016-11-01

    Donation after circulatory death (DCD) represents a potential new source of hearts to increase the donor pool. We showed previously that DCD hearts in Greyhound dogs could be resuscitated and preserved by continuous cold crystalloid perfusion but not by cold static storage and could demonstrate excellent contractile and metabolic function on an in vitro system. In the current study, we demonstrate that resuscitated DCD hearts are transplantable. Donor Greyhound dogs (n = 12) were divided into perfusion (n = 8) and cold static storage (n = 4) groups. General anesthesia was induced and ventilation ceased for 30 minutes to achieve circulatory death. Donor cardiectomy was performed, and for 4 hours the heart was preserved by controlled reperfusion, followed by continuous cold perfusion with an oxygenated crystalloid perfusate or by static cold storage, after which orthotopic heart transplantation was performed. Recovery was assessed over 4 hours by hemodynamic monitoring. During cold perfusion, hearts showed continuous oxygen consumption and low lactate levels, indicating aerobic metabolism. The 8 dogs in the perfusion group were weaned off bypass, and 4 hours after bypass produced cardiac output of 4.73 ± 0.51 liters/min, left ventricular power of 7.63 ± 1.32 J/s, right ventricular power of 1.40 ± 0.43 J/s, and left ventricular fractional area shortening of 39.1% ± 5.2%, all comparable to pre-transplant values. In the cold storage group, 3 of 4 animals could not be weaned from cardiopulmonary bypass, and the fourth exhibited low-level function. Cold crystalloid perfusion, but not cold static storage, can resuscitate and preserve the DCD donor heart in a canine model of heart transplantation, thus rendering it transplantable. Controlled reperfusion and cold crystalloid perfusion have potential for clinical application in DCD transplantation. Copyright © 2016. Published by Elsevier Inc.

  5. A first-in-man study of the Reitan catheter pump for circulatory support in patients undergoing high-risk percutaneous coronary intervention.

    Science.gov (United States)

    Smith, Elliot J; Reitan, Oyvind; Keeble, Thomas; Dixon, Kerry; Rothman, Martin T

    2009-06-01

    To investigate the safety of a novel percutaneous circulatory support device during high-risk percutaneous coronary intervention (PCI). The Reitan catheter pump (RCP) consists of a catheter-mounted pump-head with a foldable propeller and surrounding cage. Positioned in the descending aorta the pump creates a pressure gradient, reducing afterload and enhancing organ perfusion. Ten consecutive patients requiring circulatory support underwent PCI; mean age 71 +/- 9; LVEF 34% +/- 11%; jeopardy score 8 +/- 2.3. The RCP was inserted via the femoral artery. Hemostasis was achieved using Perclose sutures. PCI was performed via the radial artery. Outcomes included in-hospital death, MI, stroke, and vascular injury. Hemoglobin (Hb), free plasma Hb (fHb), platelets, and creatinine (cre) were measured pre PCI and post RCP removal. The pump was inserted and operated successfully in 9/10 cases (median 79 min). Propeller rotation at 10,444 +/- 1,424 rpm maintained an aortic gradient of 9.8 +/- 2 mm Hg. Although fHb increased, there was no significant hemolysis (4.7 +/- 2.4 mg/dl pre vs. 11.9 +/- 10.5 post, P = 0.04, reference 20 mg/dl). Platelets were unchanged (pre 257 +/- 74 x 10(9) vs. 245 +/- 63, P = NS). Renal function improved (cre pre 110 +/- 27 micromol/l vs. 99 +/- 28, P = 0.004). The RCP was not used in one patient following femoral introducer sheath related aortic dissection. All PCI procedures were successful with no deaths or strokes, one MI, and no vascular complications following pump removal. The RCP can be used safely in high-risk PCI patients. This device may be an alternative to other percutaneous systems when substantial cardiac support is needed. (c) 2009 Wiley-Liss, Inc.

  6. Fabrication of divertor mock-up with ODS-Cu and W by the improved brazing technique

    Science.gov (United States)

    Tokitani, M.; Hamaji, Y.; Hiraoka, Y.; Masuzaki, S.; Tamura, H.; Noto, H.; Tanaka, T.; Muroga, T.; Sagara, A.; FFHR Design Group

    2017-07-01

    Copper alloy has been considered as a divertor cooling tube or heat sink not only in the helical reactor FFHR-d1 but also in the tokamak DEMO reactor, because it has a high thermal conductivity. This work focused on applying an oxide dispersion strengthened copper alloy (ODS-Cu), GlidCop® (Cu-0.3 wt%Al2O3) as the divertor heat sink material of FFHR-d1. This alloy has superior high temperature yield strength exceeding 300 MPa at room temperature even after annealing up to ~1000 °C. The change in material properties of Pure-Cu, GlidCop® and CuCrZr by neutron irradiation are summarized in this paper. A primary dose limit is the radiation-induced hardening/softening (~0.2 dpa/1-2 dpa) which has a temperature dependence. According to such an evaluation, the GlidCop® can be selected as the current best candidate material in the commercial base of the divertor heat sink, and its temperature should be maintained as close as possible to 300 °C during operation. Bonding between the W armour and the GlidCop® heat sink was successfully performed by using an improved brazing technique with BNi-6 (Ni-11%P) filler material. The bonding strength was measured by a three-point bending test and reached up to approximately 200 MPa. Surprisingly, several specimens showed an obvious yield point. This means that the BNi-6 brazing (bonding) layer caused relaxation of the applied stress. The small-scale divertor mock-up of the W/BNi-6/GlidCop® was successfully fabricated by using the improved brazing technique. The heat loading test was carried out by the electron beam device ACT2 in NIFS. The mock-up showed an excellent heat removal capability for use in the FFHR-d1 divertor.

  7. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    Science.gov (United States)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support

  8. Statement of Facts for 1985 City-Wide Mock Trial Competitions. Gale Kaufman, Plaintiff v. Rolling Hills Homemakers Association, Defendant. No. MT-85.

    Science.gov (United States)

    National Inst. for Citizen Education in the Law, Washington, DC.

    Prepared by the District of Columbia Street Law Project for its 14th annual city-wide mock trial competition, this instructional handout provides the material for a civil case over discrimination in housing. After the death of her husband, Cindi Kaufman, along with her infant son, moved in with her mother, Gale Kaufman, who owned a condominium at…

  9. The Mock LISA Data Challenges: from Challenge 1B to Challenge 3

    International Nuclear Information System (INIS)

    Babak, Stanislav; Porter, Edward K; Gair, Jonathan; Baker, John G; Arnaud, Keith; Benacquista, Matthew J; Cornish, Neil J; Crowder, Jeff; Vallisneri, Michele; Cutler, Curt; Larson, Shane L; Plagnol, Eric; Vecchio, Alberto; Barack, Leor; Blaut, Arkadiusz; Fairhurst, Stephen; Harry, Ian; Gong Xuefei; Khurana, Deepak; Krolak, Andrzej

    2008-01-01

    The Mock LISA Data Challenges are a programme to demonstrate and encourage the development of LISA data-analysis capabilities, tools and techniques. At the time of this workshop, three rounds of challenges had been completed, and the next was about to start. In this paper we provide a critical analysis of the entries to the latest completed round, Challenge 1B. The entries confirm the consolidation of a range of data-analysis techniques for galactic and massive-black-hole binaries, and they include the first convincing examples of detection and parameter estimation of extreme-mass-ratio inspiral sources. In this paper we also introduce the next round, Challenge 3. Its data sets feature more realistic waveform models (e.g., galactic binaries may now chirp, and massive-black-hole binaries may precess due to spin interactions), as well as new source classes (bursts from cosmic strings, isotropic stochastic backgrounds) and more complicated nonsymmetric instrument noise

  10. Neutronics experiments for uncertainty assessment of tritium breeding in HCPB and HCLL blanket mock-ups irradiated with 14 MeV neutrons

    International Nuclear Information System (INIS)

    Batistoni, P.; Angelone, M.; Pillon, M.; Villari, R.; Fischer, U.; Klix, A.; Leichtle, D.; Kodeli, I.; Pohorecki, W.

    2012-01-01

    Two neutronics experiments have been carried out at 14 MeV neutron sources on mock-ups of the helium cooled pebble bed (HCBP) and the helium cooled lithium lead (HCLL) variants of ITER test blanket modules (TBMs). These experiments have provided an experimental validation of the calculations of the tritium production rate (TPR) in the two blanket concepts and an assessment of the uncertainties due to the uncertainties on nuclear data. This paper provides a brief summary of the HCPB experiment and then focuses in particular on the final results of the HCLL experiment. The TPR has been measured in the HCLL mock-up irradiated for long times at the Frascati 14 MeV Neutron Generator (FNG). Redundant and well-assessed experimental techniques have been used to measure the TPR by different teams for inter-comparison. Measurements of the neutron and gamma-ray spectra have also been performed. The analysis of the experiment, carried out by the MCNP code with FENDL-2.1 and JEFF-3.1.1 nuclear data libraries, and also including sensitivity/uncertainty analysis, shows good agreement between measurements and calculations, within the total uncertainty of 5.9% at 1σ level. (paper)

  11. A constitutive model for the thermo-mechanical behaviour of fusion-relevant pebble beds and its application to the simulation of HELICA mock-up experimental results

    International Nuclear Information System (INIS)

    Vella, G.; Maio, P.A. Di; Giammusso, R.; Tincani, A.; Orco, G. Dell

    2006-01-01

    Within the framework of the activities promoted by European Fusion Development Agreement on the technology of the Helium Cooled Pebble Bed Test Blanket Module to be irradiated in one of the ITER equatorial ports, attention has been focused on the theoretical modelling of the thermo-mechanical constitutive behaviour of both beryllium and lithiated ceramics pebble beds, that are envisaged to act respectively as neutron multiplier and tritium breeder. The thermo-mechanical behaviour of the pebble beds and their nuclear performances in terms of tritium production depend on the reactor relevant conditions (heat flux and neutron wall load), the pebble sizes and the breeder cell geometries (bed thickness, pebble packing factor, bed overall thermal conductivity). ENEA-Brasimone and the Department of Nuclear Engineering (DIN) of the Palermo University have performed intense research activities intended to investigate fusion-relevant pebble bed thermo-mechanical behaviour by adopting both experimental and theoretical approaches. In particular, ENEA has carried out several experimental campaigns on small scale mock-ups tested in out-of-pile conditions, while DIN has developed a proper constitutive model that has been implemented on commercial FEM code, for the prediction of the thermal and mechanical performances of fusion-relevant pebble beds and for the comparison with the experimental results of the ENEA tests. In that framework, HELICA mock-up has been set-up and tested to investigate the behaviour of pebble bed in reactor-relevant geometries, providing useful data sets to be numerically reproduced by means of the DIN constitutive model, contributing to its assessment. The paper presents the constitutive model developed and the main experimental results of two test campaigns on HELICA mock-up carried out at HE-FUS 3 facility of ENEA Brasimone, the geometry of the mock-up, the adopted thermal and mechanical boundary conditions and the test operating conditions. The most

  12. A constrained Metropolis-Hastings search for EMRIs in the Mock LISA Data Challenge 1B

    International Nuclear Information System (INIS)

    Gair, Jonathan R; Porter, Edward; Babak, Stanislav; Barack, Leor

    2008-01-01

    We describe a search for the extreme-mass-ratio inspiral sources in the Round 1B Mock LISA Data Challenge data sets. The search algorithm is a Monte Carlo search based on the Metropolis-Hastings algorithm, but also incorporates simulated, thermostated and time annealing, plus a harmonic identification stage designed to reduce the chance of the chain locking onto secondary maxima. In this paper, we focus on describing the algorithm that we have been developing. We give the results of the search of the Round 1B data, although parameter recovery has improved since that deadline. Finally, we describe several modifications to the search pipeline that we are currently investigating for incorporation in future searches

  13. Development of Highly Sensitive and Specific mRNA Multiplex System (XCYR1) for Forensic Human Body Fluids and Tissues Identification

    Science.gov (United States)

    Xu, Yan; Xie, Jianhui; Cao, Yu; Zhou, Huaigu; Ping, Yuan; Chen, Liankang; Gu, Lihua; Hu, Wei; Bi, Gang; Ge, Jianye; Chen, Xin; Zhao, Ziqin

    2014-01-01

    The identification of human body fluids or tissues through mRNA-based profiling is very useful for forensic investigations. Previous studies have shown mRNA biomarkers are effective to identify the origin of biological samples. In this study, we selected 16 tissue specific biomarkers to evaluate their specificities and sensitivities for human body fluids and tissues identification, including porphobilinogen deaminase (PBGD), hemoglobin beta (HBB) and Glycophorin A (GLY) for circulatory blood, protamine 2 (PRM2) and transglutaminase 4 (TGM4) for semen, mucin 4 (MUC4) and human beta defensin 1(HBD1) for vaginal secretion, matrix metalloproteinases 7 and 11 (MMP7 and MMP11) for menstrual blood, keratin 4(KRT4) for oral mucosa, loricrin (LOR) and cystatin 6 (CST6) for skin, histatin 3(HTN3) for saliva, statherin (STATH) for nasal secretion, dermcidin (DCD) for sweat and uromodulin (UMOD) for urine. The above mentioned ten common forensic body fluids or tissues were used in the evaluation. Based on the evaluation, a reverse transcription (RT) PCR multiplex assay, XCYR1, which includes 12 biomarkers (i.e., HBB, GLY, HTN3, PRM2, KRT4, MMP11, MUC4, DCD, UMOD, MMP7, TGM4, and STATH) and 2 housekeeping genes [i.e., glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and 18SrRNA], was developed. This assay was further validated with real casework samples and mock samples (with both single source and mixture) and it was approved that XCYR1 is effective to identify common body fluids or tissues (i.e., circulatory blood, saliva, semen, vaginal secretion, menstrual blood, oral mucosa, nasal secretion, sweat and urine) in forensic casework samples. PMID:24991806

  14. Multiple D3-Instantons and Mock Modular Forms I

    Science.gov (United States)

    Alexandrov, Sergei; Banerjee, Sibasish; Manschot, Jan; Pioline, Boris

    2017-07-01

    We study D3-instanton corrections to the hypermultiplet moduli space in type IIB string theory compactified on a Calabi-Yau threefold. In a previous work, consistency of D3-instantons with S-duality was established at first order in the instanton expansion, using the modular properties of the M5-brane elliptic genus. We extend this analysis to the two-instanton level, where wall-crossing phenomena start playing a role. We focus on the contact potential, an analogue of the Kähler potential which must transform as a modular form under S-duality. We show that it can be expressed in terms of a suitable modification of the partition function of D4-D2-D0 BPS black holes, constructed out of the generating function of MSW invariants (the latter coincide with Donaldson-Thomas invariants in a particular chamber). Modular invariance of the contact potential then requires that, in the case where the D3-brane wraps a reducible divisor, the generating function of MSW invariants must transform as a vector-valued mock modular form, with a specific modular completion built from the MSW invariants of the constituents. Physically, this gives a powerful constraint on the degeneracies of BPS black holes. Mathematically, our result gives a universal prediction for the modular properties of Donaldson-Thomas invariants of pure two-dimensional sheaves.

  15. Capture of circulatory endothelial progenitor cells and accelerated re-endothelialization of a bio-engineered stent in human ex vivo shunt and rabbit denudation model

    NARCIS (Netherlands)

    K. Larsen (Katarína); C. Cheng (Caroline (Ka Lai)); D. Tempel (Dennie); S. Parker (Sherry); S. Yazdani (Saami); W.K. den Dekker (Wijnand); H.J. Houtgraaf (Jaco); R. de Jong (Renate); S. Swager-ten Hoor (Stijn); E. Ligtenberg (Erik); S.R. Hanson (Stephen); R. Rowland (Steve); F. Kolodgie (Frank); P.W.J.C. Serruys (Patrick); R. Virmani (Renu); H.J. Duckers (Henricus)

    2012-01-01

    textabstractThe Genous™ Bio-engineered R™ stent (GS) aims to promote vascular healing by capture of circulatory endothelial progenitor cells (EPCs) to the surface of the stent struts, resulting in accelerated re-endothelialization. Here, we assessed the function of the GS in comparison to bare-metal

  16. Initial in vitro testing of a paediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader

    2018-06-01

    Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.

  17. Accidental Release of Chlorine from a Storage Facility and an On-Site Emergency Mock Drill: A Case Study

    Directory of Open Access Journals (Sweden)

    Ambalathumpara Raman Soman

    2015-01-01

    Full Text Available In the current industrial scenario there is a serious need for formulating strategies to handle hazardous substances in the safest way. Manufacture, storage, and use of hazardous substances pose a serious risk to industry, people, and the environment. Accidental release of toxic chemicals can lead to emergencies. An emergency response plan (ERP is inevitable to minimize the adverse effects of such releases. The on-site emergency plan is an integral component of any process safety and risk management system. This paper deals with an on-site emergency response plan for a chlorine manufacturing industry. It was developed on the basis of a previous study on chlorine release and a full scale mock drill has been conducted for testing the plan. Results indicated that properly trained personnel can effectively handle each level of incidents occurring in the process plant. As an extensive guideline to the district level government authorities for off-site emergency planning, risk zone has also been estimated with reference to a chlorine exposure threshold of 3 ppm.

  18. Results of Tank-Leak Detection Demonstration Using Geophysical Techniques at the Hanford Mock Tank Site-Fiscal Year 2001

    Energy Technology Data Exchange (ETDEWEB)

    Barnett, D BRENT.; Gee, Glendon W.; Sweeney, Mark D.

    2002-03-01

    During July and August of 2001, Pacific Northwest National Laboratory (PNNL), hosted researchers from Lawrence Livermore and Lawrence Berkeley National laboratories, and a private contractor, HydroGEOPHYSICS, Inc., for deployment of the following five geophysical leak-detection technologies at the Hanford Site Mock Tank in a Tank Leak Detection Demonstration (TLDD): (1) Electrical Resistivity Tomography (ERT); (2) Cross-Borehole Electromagnetic Induction (CEMI); (3) High-Resolution Resistivity (HRR); (4) Cross-Borehole Radar (XBR); and (5) Cross-Borehole Seismic Tomography (XBS). Under a ''Tri-party Agreement'' with Federal and state regulators, the U.S. Department of Energy will remove wastes from single-shell tanks (SSTs) and other miscellaneous underground tanks for storage in the double-shell tank system. Waste retrieval methods are being considered that use very little, if any, liquid to dislodge, mobilize, and remove the wastes. As additional assurance of protection of the vadose zone beneath the SSTs, tank wastes and tank conditions may be aggressively monitored during retrieval operations by methods that are deployed outside the SSTs in the vadose zone.

  19. Inactive trials of transport systems: phase II

    International Nuclear Information System (INIS)

    Haberlin, M.M.; Hardy, A.R.; Kennedy, S.T.

    1986-11-01

    Progress made during 1984-85 is reviewed in four sections: the design and installation of a stainless steel working floor in the mock-up of a crate handling and size reduction facility; the detailed evaluation of a single air pad of the type used on commercial air-transporter; an experimental programme designed to examine the problems associated with the operation of a commercial air-transporter; the design, manufacture and commissioning trials of two powered conveyor units which when combined complete a remotely operated transfer system for transporting crated waste into and within the mock-up facility. (author)

  20. Development of mechanical circulatory support devices in China.

    Science.gov (United States)

    Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang

    2009-11-01

    Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.

  1. Development of laser cutting/welding system for remote maintenance of ITER manifold

    Energy Technology Data Exchange (ETDEWEB)

    Yamaoka, Hiroto; Tsuchiya, Kazuyuki; Awano, Toshihiko [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan); Oka, Kiyoshi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2002-09-01

    A remote pipe cutting/welding system using a YAG laser was designed and fabricated for the maintenance of the main structural parts of ITER (International Thermonuclear Experimental Reactor), and a mock-up test carried out. The functions of this system are to cut 100A x Sch 40 pipes of SUS316L by internal access, to adjust the core gap between the as-cut pipe and new pipe, and to weld the pipes automatically. The core gap of the pipes could be decreased within the proper welding conditions by the mock-up test, and sound beads were obtained. (author)

  2. Local expansion in circulatory death kidney transplant activity improves wait-listed outcomes and addresses inequities of access to transplantation

    OpenAIRE

    Mirshekar-Syahkal, Bahar; Summers, Dominic; Bradbury, Lisa L; Aly, Mohamed; Bardsley, Victoria; Berry, Miriam; Norris, Joseph M; Torpey, Nick; Clatworthy, Menna Ruth; Bradley, J Andrew; Pettigrew, Gavin John

    2016-01-01

    In the UK, circulatory death (DCD) kidney transplant activity has increased rapidly, but marked regional variation persists. We report how increased DCD kidney transplant activity influenced wait-listed outcomes for a single centre. Between 2002/03 and 2011/12, 430 (54%) DCD and 361 (46%) DBD kidney-only transplants were performed in the Cambridge Transplant Centre, with a higher proportion of DCD donors fulfilling expanded criteria status (41% DCD vs 32% DBD; $\\small \\textit{P}$=0.01). Compa...

  3. The Mock-up of the "Ratto Delle Sabine" by Giambologna: Making and Utilization of a 3D Model

    Directory of Open Access Journals (Sweden)

    Grazia Tucci

    2015-02-01

    Full Text Available Within a project for the knowledge and preservation of the mock-up of Giambologna's Ratto delle Sabine housed in the Galleria dell'Accademia in Florence, the GeCO laboratory has made laser scanner acquisitions to create surface models at different resolutions for structural analysis, on which to check the coverage of the photographic campaign and to create a three-dimensional thematic mapping of data relating to investigations and restoration works. The PDF3D file format has been used to easily manage data on a platform immediately available to all operators.

  4. Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

    Science.gov (United States)

    Convertino, V. A.; Koenig, S. C.; Krotov, V. P.; Fanton, J. W.; Korolkov, V. I.; Trambovetsky, E. V.; Ewert, D. L.; Truzhennikov, A.; Latham, R. D.

    1998-01-01

    Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

  5. Characterizing Cyberbullying among College Students: Hacking, Dirty Laundry, and Mocking

    Directory of Open Access Journals (Sweden)

    Rajitha Kota

    2014-10-01

    Full Text Available Bullying behaviors occur across the lifespan and have increasingly migrated to online platforms where they are known as cyberbullying. The purpose of this study was to explore the phenomenon of cyberbullying among college students. Participants were recruited for focus groups through purposeful sampling, including recruitment from groups traditionally at risk for bullying. Focus groups discussed views and perceptions of cyberbullying on campuses. Groups were led by a trained facilitator and were audio recorded and manually transcribed. The constant comparative approach was used to identify themes and representative quotations. The 42 participants had an average age of 19.2 (SD = 1.2, 55% were female, 83% were Caucasian. Three themes emerged from the data: (1 lack of agreement on a definition of cyberbullying, but consensus on three representative scenarios: hacking, dirty laundry and mocking; (2 concerns with translating definitions of traditional bullying to cyberbullying; (3 opinions that cyberbullying may manifest differently in college compared to younger adolescents, including increased potential for long-term effects. College students were not in agreement about a theoretical definition, but they could agree upon specific representative instances of cyberbullying.  Future studies could consider using common case examples or vignettes of cyberbullying, or creation of developmentally representative definitions by age group.

  6. Feigning Amnesia Moderately Impairs Memory for a Mock Crime Video.

    Science.gov (United States)

    Mangiulli, Ivan; van Oorsouw, Kim; Curci, Antonietta; Merckelbach, Harald; Jelicic, Marko

    2018-01-01

    Previous studies showed that feigning amnesia for a crime impairs actual memory for the target event. Lack of rehearsal has been proposed as an explanation for this memory-undermining effect of feigning. The aim of the present study was to replicate and extend previous research adopting a mock crime video instead of a narrative story. We showed participants a video of a violent crime. Next, they were requested to imagine that they had committed this offense and to either feign amnesia or confess the crime. A third condition was included: Participants in the delayed test-only control condition did not receive any instruction. On subsequent recall tests, participants in all three conditions were instructed to report as much information as possible about the offense. On the free recall test, feigning amnesia impaired memory for the video clip, but participants who were asked to feign crime-related amnesia outperformed controls. However, no differences between simulators and confessors were found on both correct cued recollection or on distortion and commission rates. We also explored whether inner speech might modulate memory for the crime. Inner speech traits were not found to be related to the simulating amnesia effect. Theoretical and practical implications of our results are discussed.

  7. Feigning Amnesia Moderately Impairs Memory for a Mock Crime Video

    Directory of Open Access Journals (Sweden)

    Ivan Mangiulli

    2018-04-01

    Full Text Available Previous studies showed that feigning amnesia for a crime impairs actual memory for the target event. Lack of rehearsal has been proposed as an explanation for this memory-undermining effect of feigning. The aim of the present study was to replicate and extend previous research adopting a mock crime video instead of a narrative story. We showed participants a video of a violent crime. Next, they were requested to imagine that they had committed this offense and to either feign amnesia or confess the crime. A third condition was included: Participants in the delayed test-only control condition did not receive any instruction. On subsequent recall tests, participants in all three conditions were instructed to report as much information as possible about the offense. On the free recall test, feigning amnesia impaired memory for the video clip, but participants who were asked to feign crime-related amnesia outperformed controls. However, no differences between simulators and confessors were found on both correct cued recollection or on distortion and commission rates. We also explored whether inner speech might modulate memory for the crime. Inner speech traits were not found to be related to the simulating amnesia effect. Theoretical and practical implications of our results are discussed.

  8. COCOA code for creating mock observations of star cluster models

    Science.gov (United States)

    Askar, Abbas; Giersz, Mirek; Pych, Wojciech; Dalessandro, Emanuele

    2018-04-01

    We introduce and present results from the COCOA (Cluster simulatiOn Comparison with ObservAtions) code that has been developed to create idealized mock photometric observations using results from numerical simulations of star cluster evolution. COCOA is able to present the output of realistic numerical simulations of star clusters carried out using Monte Carlo or N-body codes in a way that is useful for direct comparison with photometric observations. In this paper, we describe the COCOA code and demonstrate its different applications by utilizing globular cluster (GC) models simulated with the MOCCA (MOnte Carlo Cluster simulAtor) code. COCOA is used to synthetically observe these different GC models with optical telescopes, perform point spread function photometry, and subsequently produce observed colour-magnitude diagrams. We also use COCOA to compare the results from synthetic observations of a cluster model that has the same age and metallicity as the Galactic GC NGC 2808 with observations of the same cluster carried out with a 2.2 m optical telescope. We find that COCOA can effectively simulate realistic observations and recover photometric data. COCOA has numerous scientific applications that maybe be helpful for both theoreticians and observers that work on star clusters. Plans for further improving and developing the code are also discussed in this paper.

  9. Eddy current testing system for bottom mounted instrumentation welds - 15206

    International Nuclear Information System (INIS)

    Kobayashi, N.; Ueno, S.; Suganuma, N.; Oodake, T.; Maehara, T.; Kasuya, T.; Ichikawa, H.

    2015-01-01

    We have demonstrated the scanning of eddy current testing (ECT) probe on the welds area including the nozzle, the J-welds and the buildup welds of the Bottom Mounted Instrumentation (BMI) mock-up using the developed ECT system and procedure. It is difficult to scan the probe on the BMI welds area because the area has a complex curved surface shape and narrow spaces. We made the space coordinates and the normal vectors on the scanning points as the scanning trajectory of probe on the welds area based on the measured results of welds surface shape on the mock-up. The multi-axis robot was used to scan the probe on the welds surface. Each motion axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. The BMI mock-up test was performed using the cross coil probe in the differential mode. The artificial stress corrosion cracking and the electrical discharge machining slits given on the mock-up surface were detected. The results show that the ECT can detect a defect of approximately 2.3 mm in length, 0.5 mm in depth and 0.2 mm in width for the BMI welds. From the output voltage of single coil, we estimated that the average and the maximum probe tilt angles on the mock-up surface under scanning were 2.6 degrees and 8.5 degrees, respectively

  10. Concepção de bancada e montagem de experimento para a análise in vitro de próteses cardíacas mitrais Design conception and experimental setup for in vitro evaluation of mitral prosthetic valves

    Directory of Open Access Journals (Sweden)

    Ovandir Bazan

    2011-06-01

    prosthetic heart valves is due to disturbances of flow, its hydrodynamic characterization is a useful aid in the design of new prostheses. Simulations of pulsatile flow in cardiac prostheses began nearly 40 years ago, through the development of different mock human circulatory systems, improving the clinical results interpretation. A new design of a pulse duplicator system was developed at Polytechnic School of USP to study prosthetic heart valves. OBJECTIVE: To present the conception of a new mock circulatory system for hydrodynamic simulations of cardiac prosthetic valves and the assembly plan of an experiment whose focus is the test of mitral prosthesis. METHODS: Its conception is based on the state-of-art's review of these studies and the experience got with the previous mock circulatory systems, particularly the one used in the Instituto Dante Pazzanese de Cardiologia, São Paulo, SP, Brazil. RESULTS: In this design, an electric servomotor controlled by computer emits, through a hydraulic piston, a pulse to the left ventricular chamber model, where the heart valves are accomodated. To characterize, in the future, the dynamic operation of mitral prosthetic valves, an experimental setup was mounted to provide measurements of volumetric flow, instantaneous pressure and velocity fields on these valves. Optical access is conveniently provided on the design, making possible the use, in the future, of a LDA system. CONCLUSIONS: In order to improve the analysis of hydrodynamic shear stress and prediction of haemolysis, the experimental results may be used to regulate a numerical model using 'Computational Fluid Dynamics' (CFD.

  11. Examination of C/C flat tile mock-ups with hypervapotron cooling after high heat flux testing

    International Nuclear Information System (INIS)

    Schedler, B.; Friedrich, T.; Traxler, H.; Eidenberger, E.; Scheu, C.; Clemens, H.; Pippan, R.; Escourbiac, F.

    2007-01-01

    Two C/C flat tile mock-ups with a hypervapotron cooling concept, have been successfully tested beyond ITER specification (3000 cycles at 15 MW/m 2 , 300 cycles at 20 MW/m 2 and 800-1000 cycles at 25 MW/m 2 ) in two electron beam testing facilities [F. Escourbiac, et al., Experimental simulation of cascade failure effect on tungsten and CFC flat tile armoured HHF components, Fusion Eng. Des., submitted for publication; F. Escourbiac, et al., A mature industrial solution for ITER divertor plasma facing components: hypervapotron cooling concept adapted to Tore Supra flat tile technology, Fusion Eng. Des. 75-79 (2005) 387-390]. Both mock-ups provide a SNECMA SEPCARB NS31 armour, which has been joined onto the CuCrZr heat sink by active metal casting (AMC) and electron beam welding (EBW). No tile detachment or sudden loss of single tiles has been observed; a cascade-like failure of flat tile armours was impossible to generate. At the maximum cyclic heat flux load of 25 MW/m 2 all tested tiles performed well except one, which revealed already a clear indication in the thermographic examination at the end of the manufacture. Visual examination and analysis of metallographic cuts of the remaining tiles demonstrated that the interface has not been altered. In addition, the shear strength of the C/C to copper joints measured after the high heat flux (HHF) test has been found to be still above the interlamellar shear strength of the used C/C material. The high resistance of the interface is explained by a modification of the C/C to copper joint interface due to silicon originating from the used C/C material

  12. Examination of C/C flat tile mock-ups with hypervapotron cooling after high heat flux testing

    Energy Technology Data Exchange (ETDEWEB)

    Schedler, B. [Technology Centre of PLANSEE SE, A-6600 Reutte (Austria)], E-mail: bertram.schedler@plansee.com; Friedrich, T.; Traxler, H. [Technology Centre of PLANSEE SE, A-6600 Reutte (Austria); Eidenberger, E.; Scheu, C.; Clemens, H. [Department of Physical Metallurgy and Materials Testing, University of Leoben, A-8700 Leoben (Austria); Pippan, R. [Austrian Academy of Sciences, Erich-Schmid-Institute of Material Science, A-8700 Leoben (Austria); Escourbiac, F. [Association EURATOM-CEA, DSM/DRFC, CEA Cadarache, F-13108 St. Paul Lez Durance (France)

    2007-04-15

    Two C/C flat tile mock-ups with a hypervapotron cooling concept, have been successfully tested beyond ITER specification (3000 cycles at 15 MW/m{sup 2}, 300 cycles at 20 MW/m{sup 2} and 800-1000 cycles at 25 MW/m{sup 2}) in two electron beam testing facilities [F. Escourbiac, et al., Experimental simulation of cascade failure effect on tungsten and CFC flat tile armoured HHF components, Fusion Eng. Des., submitted for publication; F. Escourbiac, et al., A mature industrial solution for ITER divertor plasma facing components: hypervapotron cooling concept adapted to Tore Supra flat tile technology, Fusion Eng. Des. 75-79 (2005) 387-390]. Both mock-ups provide a SNECMA SEPCARB NS31 armour, which has been joined onto the CuCrZr heat sink by active metal casting (AMC) and electron beam welding (EBW). No tile detachment or sudden loss of single tiles has been observed; a cascade-like failure of flat tile armours was impossible to generate. At the maximum cyclic heat flux load of 25 MW/m{sup 2} all tested tiles performed well except one, which revealed already a clear indication in the thermographic examination at the end of the manufacture. Visual examination and analysis of metallographic cuts of the remaining tiles demonstrated that the interface has not been altered. In addition, the shear strength of the C/C to copper joints measured after the high heat flux (HHF) test has been found to be still above the interlamellar shear strength of the used C/C material. The high resistance of the interface is explained by a modification of the C/C to copper joint interface due to silicon originating from the used C/C material.

  13. Use of hydraulic and aerial mock up to study atmospheric pollution

    International Nuclear Information System (INIS)

    Facy, L.; Perrin De Brichambaut, C.; Doury, A.; Le Quinio, R.

    1962-01-01

    Fundamental studies on turbulent atmospheric diffusion of finely divided particles, cannot remain on a purely theoretical basis. Further experimental studies must be considered. - In full scale, from accidental and induced releases. - On a reduced scale, in aerodynamic wind tunnels or hydraulic water tunnels. A first set of studies on reduced scale models has been worked out according to a contract between French 'Meteorologie Nationale' and French 'Commissariat a l'Energie Atomique' and with the Collaboration of Saint-Cyr 'Institut Aerotechnique'. Essentially two kinds of results have been obtained: - The mathematical model of SUTTON for the turbulent diffusion in the atmosphere, deduced from the SUTTON theory, generally used by us, has been correctly verified, qualitatively and quantitatively whenever experiments were consistent with the theory conditions. - The quantitative assays of photographic and cinematographic visualization have given precise details on the phenomena inaccessible to calculations, due to the influence of obstacles and release conditions. - Generally, it can be asserted, that the atmospheric pollution studies are worked out by mock up experimentations and that, in some cases these experiments never can be replaced by mathematically pure models. (authors) [fr

  14. Utilization of organs from donors after circulatory death for vascularized pancreas and islet of Langerhans transplantation: recommendations from an expert group.

    Science.gov (United States)

    Berney, Thierry; Boffa, Catherine; Augustine, Titus; Badet, Lionel; de Koning, Eelco; Pratschke, Johann; Socci, Carlo; Friend, Peter

    2016-07-01

    Donation after circulatory death (DCD) donors are increasingly being used as a source of pancreas allografts for vascularized organ and islet transplantation. We provide practice guidelines aiming to increase DCD pancreas utilization. We review risk assessment and donor selection criteria. We report suggested factors in donor and recipient clinical management and provide an overview of the activities and outcomes of vascularized pancreas and islet transplantation. © 2015 Steunstichting ESOT.

  15. Circulatory CNP Rescues Craniofacial Hypoplasia in Achondroplasia.

    Science.gov (United States)

    Yamanaka, S; Nakao, Kazumasa; Koyama, N; Isobe, Y; Ueda, Y; Kanai, Y; Kondo, E; Fujii, T; Miura, M; Yasoda, A; Nakao, Kazuwa; Bessho, K

    2017-12-01

    Achondroplasia is the most common genetic form of human dwarfism, characterized by midfacial hypoplasia resulting in occlusal abnormality and foramen magnum stenosis, leading to serious neurologic complications and hydrocephalus. Currently, surgery is the only way to manage jaw deformity, neurologic complications, and hydrocephalus in patients with achondroplasia. We previously showed that C-type natriuretic peptide (CNP) is a potent stimulator of endochondral bone growth of long bones and vertebrae and is also a potent stimulator in the craniofacial region, which is crucial for midfacial skeletogenesis. In this study, we analyzed craniofacial morphology in a mouse model of achondroplasia, in which fibroblast growth factor receptor 3 (FGFR3) is specifically activated in cartilage ( Fgfr3 ach mice), and investigated the mechanisms of jaw deformities caused by this mutation. Furthermore, we analyzed the effect of CNP on the maxillofacial area in these animals. Fgfr3 ach mice exhibited midfacial hypoplasia, especially in the sagittal direction, caused by impaired endochondral ossification in craniofacial cartilage and by premature closure of the spheno-occipital synchondrosis, an important growth center in craniomaxillofacial skeletogenesis. We crossed Fgfr3 ach mice with transgenic mice in which CNP is expressed in the liver under the control of the human serum amyloid-P component promoter, resulting in elevated levels of circulatory CNP ( Fgfr3 ach /SAP-Nppc-Tg mice). In the progeny, midfacial hypoplasia in the sagittal direction observed in Fgfr3 ach mice was improved significantly by restoring the thickness of synchondrosis and promoting proliferation of chondrocytes in the craniofacial cartilage. In addition, the foramen magnum stenosis observed in Fgfr3 ach mice was significantly ameliorated in Fgfr3 ach /SAP-Nppc-Tg mice due to enhanced endochondral bone growth of the anterior intraoccipital synchondrosis. These results clearly demonstrate the therapeutic

  16. Thermal fatigue testing of a diffusion-bonded beryllium divertor mock-up under ITER relevant conditions

    International Nuclear Information System (INIS)

    Youchison, D.L.; Guiniiatouline, R.; Watson, R.D.

    1994-01-01

    Thermal response and thermal fatigue tests of four 5 mm thick beryllium tiles on a Russian divertor mock-up were completed on the Electron Beam Test System at Sandia National Laboratories. The beryllium tiles were diffusion bonded onto an OFHC copper saddleblock and a DSCu (MAGT) tube containing a porous coating. Thermal response tests were performed on the tiles to an absorbed heat flux of 5 MW/m 2 and surface temperatures near 300 degrees C using 1.4 MPa water at 5.0 m/s flow velocity and an inlet temperature of 8-15 degrees C. One tile was exposed to incrementally increasing heat fluxes up to 9.5 MW/m 2 and surface temperatures up to 690 degrees C before debonding at 10 MW/m 2 . A third tile debonded after 9200 thermal fatigue cycles at 5 MW/m 2 , while another debonded after 6800 cycles. In all cases, fatigue failure occurred in the intermetallic layers between the beryllium and copper. No fatigue cracking of the bulk beryllium was observed. During thermal cycling, a gradual loss of porous coating produced increasing sample temperatures. These experiments indicate that diffusion-bonded beryllium tiles can survive several thousand thermal cycles under ITER relevant conditions without failure. However, the reliability of the diffusion bonded Joint remains a serious issue

  17. Searching for massive black hole binaries in the first Mock LISA Data Challenge

    International Nuclear Information System (INIS)

    Cornish, Neil J; Porter, Edward K

    2007-01-01

    The Mock LISA Data Challenge is a worldwide effort to solve the LISA data analysis problem. We present here our results for the massive black hole binary (BBH) section of round 1. Our results cover challenge 1.2.1, where the coalescence of the binary is seen, and challenge 1.2.2, where the coalescence occurs after the simulated observational period. The data stream is composed of Gaussian instrumental noise plus an unknown BBH waveform. Our search algorithm is based on a variant of the Markov chain Monte Carlo method that uses Metropolis-Hastings sampling and thermostated frequency annealing. We present results from the training data sets where we know the parameter values a priori and the blind data sets where we were informed of the parameter values after the challenge had finished. We demonstrate that our algorithm is able to rapidly locate the sources, accurately recover the source parameters and provide error estimates for the recovered parameters

  18. Space Radiation Cancer, Circulatory Disease and CNS Risks for Near Earth Asteroid and Mars Missions: Uncertainty Estimates for Never-Smokers

    Science.gov (United States)

    Cucinotta, Francis A.; Chappell, Lori J.; Wang, Minli; Kim, Myung-Hee

    2011-01-01

    The uncertainties in estimating the health risks from galactic cosmic rays (GCR) and solar particle events (SPE) are a major limitation to the length of space missions and the evaluation of potential risk mitigation approaches. NASA limits astronaut exposures to a 3% risk of exposure induced cancer death (REID), and protects against uncertainties in risks projections using an assessment of 95% confidence intervals after propagating the error from all model factors (environment and organ exposure, risk coefficients, dose-rate modifiers, and quality factors). Because there are potentially significant late mortality risks from diseases of the circulatory system and central nervous system (CNS) which are less well defined than cancer risks, the cancer REID limit is not necessarily conservative. In this report, we discuss estimates of lifetime risks from space radiation and new estimates of model uncertainties are described. The key updates to the NASA risk projection model are: 1) Revised values for low LET risk coefficients for tissue specific cancer incidence, with incidence rates transported to an average U.S. population to estimate the probability of Risk of Exposure Induced Cancer (REIC) and REID. 2) An analysis of smoking attributable cancer risks for never-smokers that shows significantly reduced lung cancer risk as well as overall cancer risks from radiation compared to risk estimated for the average U.S. population. 3) Derivation of track structure based quality functions depends on particle fluence, charge number, Z and kinetic energy, E. 4) The assignment of a smaller maximum in quality function for leukemia than for solid cancers. 5) The use of the ICRP tissue weights is shown to over-estimate cancer risks from SPEs by a factor of 2 or more. Summing cancer risks for each tissue is recommended as a more accurate approach to estimate SPE cancer risks. 6) Additional considerations on circulatory and CNS disease risks. Our analysis shows that an individual s

  19. Alkaline Phosphatase for the Prevention of Intestinal and Renal Injury in a Rat Model of Cardiopulmonary Bypass with Deep Hypothermic Circulatory Arrest

    Science.gov (United States)

    2017-09-01

    prevention of intestinal and kidney injury after pediatric cardiopulmonary bypass with deep hypothermic circulatory arrest. In this model, we place 5-10kg...first abstract submissions to either Pediatric Academic Society or American Thoracic Society meetings by November. Secondary analysis of serum...rats. Transition to the piglet model also had multiple benefits beyond greater consistency of surgical approach. We now have a true pediatric model and

  20. NASA Models of Space Radiation Induced Cancer, Circulatory Disease, and Central Nervous System Effects

    Science.gov (United States)

    Cucinotta, Francis A.; Chappell, Lori J.; Kim, Myung-Hee Y.

    2013-01-01

    The risks of late effects from galactic cosmic rays (GCR) and solar particle events (SPE) are potentially a limitation to long-term space travel. The late effects of highest concern have significant lethality including cancer, effects to the central nervous system (CNS), and circulatory diseases (CD). For cancer and CD the use of age and gender specific models with uncertainty assessments based on human epidemiology data for low LET radiation combined with relative biological effectiveness factors (RBEs) and dose- and dose-rate reduction effectiveness factors (DDREF) to extrapolate these results to space radiation exposures is considered the current "state-of-the-art". The revised NASA Space Risk Model (NSRM-2014) is based on recent radio-epidemiology data for cancer and CD, however a key feature of the NSRM-2014 is the formulation of particle fluence and track structure based radiation quality factors for solid cancer and leukemia risk estimates, which are distinct from the ICRP quality factors, and shown to lead to smaller uncertainties in risk estimates. Many persons exposed to radiation on earth as well as astronauts are life-time never-smokers, which is estimated to significantly modify radiation cancer and CD risk estimates. A key feature of the NASA radiation protection model is the classification of radiation workers by smoking history in setting dose limits. Possible qualitative differences between GCR and low LET radiation increase uncertainties and are not included in previous risk estimates. Two important qualitative differences are emerging from research studies. The first is the increased lethality of tumors observed in animal models compared to low LET radiation or background tumors. The second are Non- Targeted Effects (NTE), which include bystander effects and genomic instability, which has been observed in cell and animal models of cancer risks. NTE's could lead to significant changes in RBE and DDREF estimates for GCR particles, and the potential

  1. Harms of unsuccessful donation after circulatory death: An exploratory study.

    Science.gov (United States)

    Taylor, Lauren J; Buffington, Anne; Scalea, Joseph R; Fost, Norman; Croes, Kenneth D; Mezrich, Joshua D; Schwarze, Margaret L

    2018-02-01

    While donation after circulatory death (DCD) has expanded options for organ donation, many who wish to donate are still unable to do so. We conducted face-to-face interviews with family members (N = 15) who had direct experience with unsuccessful DCD and 5 focus groups with professionals involved in the donation process. We used qualitative content analysis to characterize the harms of nondonation as perceived by participants. Participants reported a broad spectrum of harms affecting organ recipients, donors, and donor families. Harms included waste of precious life-giving organs and hospital resources, inability to honor the donor's memory and character, and impaired ability for families to make sense of tragedy and cope with loss. Donor families empathized with the initial hope and ultimate despair of potential recipients who must continue their wait on the transplant list. Focus group members reinforced these findings and highlighted the struggle of families to navigate the uncertainty regarding the timing of death during the donation process. While families reported significant harm, many appreciated the donation attempt. These findings highlight the importance of organ donation to donor families and the difficult experiences associated with current processes that could inform development of alternative donation strategies. © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.

  2. Intracellular Signaling Mediators in the Circulatory and Ventilatory Systems

    CERN Document Server

    Thiriet, Marc

    2013-01-01

    The volumes in this authoritative series present a multidisciplinary approach to modeling and simulation of flows in the cardiovascular and ventilatory systems, especially multiscale modeling and coupled simulations. The cardiovascular and respiratory systems are tightly coupled, as their primary function is to supply oxygen to and remove carbon dioxide from the body's cells. Because physiological conduits have deformable and reactive walls, macroscopic flow behavior and prediction must be coupled to phenomenological models of nano- and microscopic events in a corrector scheme of regulated mechanisms when the vessel lumen caliber varies markedly. Therefore, investigation of flows of blood and air in physiological conduits requires an understanding of the biology, chemistry, and physics of these systems together with the mathematical tools to describe their functioning. Volume 4 is devoted to major sets of intracellular mediators that transmit signals upon stimulation of cell-surface receptors.  Activation of...

  3. Seismic tests on a reduced scale mock-up of a reprocessing plant cooling pond

    International Nuclear Information System (INIS)

    Queval, J.C.; Gantenbein, F.; Lebelle, M.

    1995-01-01

    In conjunction with COGEMA and SGN, CEA has launched an important research program to validate the reprocessing plant cooling pond calculation mainly for the effect of the racks on the fluid-pond interaction. The paper presents the tests performed on a reduced scale mock-up (scale 1/5). The tests are composed by: -random excitations at very low excitation level to measure the natural frequencies, especially the first sloshing mode frequency; -sinusoidal tests to measure the damping; -seismic tests performed with 3 different time reduction scales (1, 1/5, 1/√5) and 3 different synthetic accelerograms. Two types of simplified model with added masses and finite element model were developed. Comparisons of measured and calculated pressure fields against the panels will be presented. The measured frequencies, obtained during tests, are in good agreement with Housner's results. (authors). 2 refs., 4 figs., 5 tabs

  4. Physiological system integrations with emphasis on the respiratory-cardiovascular system

    Science.gov (United States)

    Gallagher, R. R.

    1975-01-01

    The integration of two types of physiological system simulations is presented. The long term model is a circulatory system model which simulates long term blood flow variations and compartmental fluid shifts. The short term models simulate transient phenomena of the respiratory, thermoregulatory, and pulsatile cardiovascular systems as they respond to stimuli such as LBNP, exercise, and environmental gaseous variations. An overview of the interfacing approach is described. Descriptions of the variable interface for long term to short term and between the three short term models are given.

  5. Hyperdynamic circulatory changes in liver cirrhosis: Comparative evaluation by doppler ultrasonography with normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dae Wook; Baik, Soon Koo; Suh, Jung In; Kim, Jae Woo; Park, Yong Soon; Kim, Hyun Soo; Lee, Dong Ki; Kwon, Sang Ok [Yonsei University, Wonju College of Medicine, Wonju (Korea, Republic of)

    2001-12-15

    To evaluate the cardiovascular and splanchnic hemodynamic changes in patients with liver cirrhosis and to compare with those of the normal controls using doppler ultrasonography. A total of 129 patients including 23 of Child-Pugh class A, 24 of class A, 24 of class B, 30 of class C, and 52 of the control group were included. Cardiac output (CO), systemic vascular resistance index (SVRI), and blood flow and pulsatility index (PI) of the superior mesenteric artery (SMA) were evaluated and compared among each groups. CO and SMA blood flow in the cirrhotic group were significantly higher than those in the control group, and the increase in CO and SMA blood flow showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SVRI and SMA PI reflecting vascular resistance in the cirrhotic group were significantly lower than those in the control group, and the decrease in SVRI and SMA PI also showed a statistically significant correlation with the degree of liver dysfunction (p<0.01). SMA blood flow showed a statistically significant inverse relationship with SMA PI (R{sup 2}=0.230). Hyperdynamic circulatory changes such as increases in CO and splanchnic blood flow were present in patients with liver cirrhosis. These changes may contribute to the development and maintenance of the portal hypertension due to an increase in portal blood flow an increase in portal blood flow.

  6. Pediatric donation after circulatory determination of death (pDCD): A narrative review.

    Science.gov (United States)

    Weiss, Matthew J; Sherry, Wendy; Hornby, Laura

    2018-04-14

    Pediatric donation after circulatory death (pDCD) is an established pathway for organ donation. It remains, however, a relatively rare event worldwide, and most clinicians outside of the pediatric intensive care unit (PICU) are unfamiliar with it. The goal of this review is to introduce the processes and concepts of pDCD. While most children die in circumstances that would not allow pDCD, many children that die after withdrawal of life sustaining therapy (WLST) may be eligible for donation of some organs. The potential benefits of this practice to patients on the wait list are well known, but donation can also be an opportunity to honor a patient's or family's desire to altruistically improve the lives of others. Offering the possibility of donation requires careful attention to ethical principles to ensure that conflicts of interest are avoided and that the family is free to make an independent, fully informed decision. Doing so allows families and decision makers the autonomy to decide if donation is something they wish to incorporate into end-of-life care. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. State of cardiovascular system during exercise in sportsmen

    Directory of Open Access Journals (Sweden)

    Usanov D.A.

    2013-03-01

    Full Text Available The purpose of the article is to study the state of cardiovascular system of sportsmen involved in rowing and canoeing, both before and after training. Material et methods: The research has been performed by means of the developed mobile devices that allow non-invasive screening assessment of the potential risk of collapse complications. Results: The article outlines the results of the survey carried out to determine the presence of vagotonic tone with deficient activity supply and abnormal pulse wave that may lead to circulatory collapse in exercise. Conclusion: The technique of pulse wave and vegetative regulation assessment before and after training enables to prevent the circulatory collapse development in stressful physical exertion in sportsmen.

  8. From the shadows into the light: How pretrial publicity and deliberation affect mock jurors' decisions, impressions, and memory.

    Science.gov (United States)

    Ruva, Christine L; Guenther, Christina C

    2015-06-01

    This 2-part study explored how exposure to negative pretrial publicity (Neg-PTP) influences the jury process, as well as possible mechanisms responsible for its biasing effects on decisions. Study Part A explored how PTP and jury deliberations affect juror/jury verdicts, memory, and impressions of the defendant and attorneys. One week before viewing a criminal trial mock-jurors (N = 320 university students) were exposed to Neg-PTP or unrelated crime stories (No-PTP). Two days later deliberating jurors came to a group decision, whereas nondeliberating jurors completed an unrelated task before making an individual decision. Neg-PTP jurors were more likely to vote guilty, make memory errors, and rate the defendant lower in credibility. Deliberation reduced Neg-PTP jurors' memory accuracy and No-PTP jurors' guilty verdicts (leniency bias). Jurors' memory and ratings of the defendant and prosecuting attorney significantly mediated the effect of PTP on guilt ratings. Study Part B content analyzed 30 mock-jury deliberations and explored how PTP influenced deliberations and ultimately jury decisions. Neg-PTP juries were more likely than No-PTP juries to discuss ambiguous trial evidence in a proprosecution manner and less likely to discuss judicial instructions and lack of evidence. All Neg-PTP juries mentioned PTP, after instructed otherwise, and rarely corrected jury members who mentioned PTP. Discussion of ambiguous trial evidence in a proprosecution manner and lack of evidence significantly mediated the effect of PTP on jury-level guilt ratings. Together the findings suggest that judicial admonishments and deliberations may not be sufficient to reduce PTP bias, because of memory errors, biased impressions, and predecisional distortion. (c) 2015 APA, all rights reserved).

  9. Modelling of cardiovascular system: development of a hybrid (numerical-physical) model.

    Science.gov (United States)

    Ferrari, G; Kozarski, M; De Lazzari, C; Górczyńska, K; Mimmo, R; Guaragno, M; Tosti, G; Darowski, M

    2003-12-01

    Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit--the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.

  10. Thermal transient and the temperature profile in a HELICA mock-up simulated by a new finite element homogenous model

    International Nuclear Information System (INIS)

    Zaccari, Nicola; Aquaro, Donato

    2013-01-01

    Highlights: • We have developed a numerical model of the pebble beds is based on the results of a theoretical and experimental research activity performed. • The model has been used to simulate the experimental tests performed on HELICA mock-up (ENEA Italy). • Moreover the numerical results are compared with the experimental ones. Finally, a discussion on results obtained by other authors involved in the benchmark is reported. -- Abstract: This paper deals with a numerical approach for simulating the thermal and mechanical behaviour of pebble beds used as breeder and neutron multiplier in breeding blanket of nuclear fusion reactor. The model of the pebble beds is based on the results of a theoretical and experimental research activity performed by the Authors on ceramic pebble beds (lithium ortosilicate and lithium metatitanate). The results of this activity permitted to determine the effective thermal conductivity of the beds, versus the temperature and the axial pressure and to implement a homogenous model of pebble bed in a FEM code. This paper illustrates an application of the implemented model, considering pebble beds under several cycles of heating and cooling. The examined geometry corresponds to the HELICA mock-up tested by ENEA in the research centre Brasimone. The experimental tests performed on HELICA have been used as a benchmark problem in order to assess the different approaches for simulating pebble beds. In this paper, the simulations performed with two-dimensional models are illustrated. Moreover the numerical results are compared with the experimental ones. Finally, a discussion on results obtained by other authors involved in the benchmark is reported

  11. The peculiarities of formation of circulatory system pathology of evacuated adult population exposed to ionizing radiation on thyroid gland after the accident at the Chernobyl Nuclear Power Plant

    Directory of Open Access Journals (Sweden)

    Kapustinskaia O.A.

    2014-11-01

    Full Text Available The aim of the research - analysis of the structure and dynamics of the morbidity among eva¬cuated population, the peculiarities of pathogenesis of the most widespread forms of circulatory system (CS pathology in the remote period after the accident at the Chernobyl Nuclear Power Plant. Materials and methods. Three groups of persons evacuated from Chernobyl zone of alienation were researched: persons aged 10-17 (6517 persons, 18-39 (496 persons, 40-60 (458 persons. The data on the individual radiation doses which affected thyroid gland were selected at the State Register of Ukraine on persons affected by the Chernobyl disaster. Morbidity rate was estimated per 103 man-year for 5-years periods of monitoring. The main results: Time from the moment of Chernobyl accident affected the formation of morbidity structure of evacuated population. It was fixed two peaks of morbidity incidence - initial and in 12 years. The most essential changes in CS morbidity of evacuated population were fixed 26 years later mainly in cere¬brovascular diseases. The coronary artery disease takes the first place in the morbidity structure. Significant dif¬ferences were detected at age-specific aspect. The evacuated adult population aged 18-39 years was the most vulnerable for the development of CS diseases. Adverse health effects confirmed the necessity of further research of CS morbidity with the differentiation of doses affected thyroid gland.

  12. A cholinergic contribution to the circulatory responses evoked at the onset of handgrip exercise in humans

    DEFF Research Database (Denmark)

    Vianna, Lauro C; Fadel, Paul J; Secher, Niels H

    2015-01-01

    A cholinergic (muscarinic) contribution to the initial circulatory response to exercise in humans remains controversial. Herein, we posit that this may be due to exercise mode with a cholinergic contribution being important during isometric handgrip exercise, where the hyperemic response......-induced fall in SVR and, thereby, augmented the pressor response (+13 ± 3 mmHg at 10 s; P exercise. These findings suggest that a cholinergic mechanism is important for the BP...... resistance (SVR) in young healthy males, while performing either 20 s of isometric handgrip contraction at 40% maximum voluntary contraction (protocol 1; n = 9) or 20 s of low-intensity leg cycling exercise (protocol 2; n = 8, 42 ± 8 W). Exercise trials were conducted under control (no drug) conditions...

  13. Ion Beam Analysis methods applied to the examination of Be//Cu joints in hipped Be tiles for ITER first wall mock- ups

    International Nuclear Information System (INIS)

    Vito, E. de; Cayron, C.; Hicham Khodja; Lorenzetto, P.

    2006-01-01

    A proposed fabrication route for ITER first wall components implies a diffusion welding step of Be tiles onto a Cu-based substrate. However, Be has a tendency to form particularly brittle intermetallics with Cu and a lot of other elements. Insertion of interlayers may be a solution to increase bond quality. Applying traditional analyses to this study can be problematic because of Be toxicity and low atomic number Z. Ion Beam Analysis methods have thus been considered together with scanning electron microscopy (SEM) and electron back-scattering diffraction (EBSD) as complementary techniques. The following work aims at demonstrating how such techniques (used in micro-beam mode), and in particular NRA (Nuclear Reaction Analysis) and PIXE (Particle Induced X-ray Emission) techniques, coupled with SEM/EBSD data, can bring valuable information in this area. Quantification of data allow to obtain concentration values (provided the hypotheses on the initial junction composition are valuable), then phase diagrams give clues about the composition and structure of the junction. SEM retro-diffused electrons chemical contrast images and EBSD allow to characterize the presence of the awaited intermetallics, and finally confirm or refine the conclusions of Ion Beam Analysis data quantification. A series of reference first wall mock-ups have been analysed. Interlayer-free mock-ups reveal intermetallics which are mainly BeCu (apparently mixed with lower quantities of BeCu 2 compound). While Cr or Ti interlayers seem to behave as good Be diffusion barriers in the sense that they prevent the formation of BeCu, they strongly interact with Cu to form CuTi 2 or Cr 2 Ti intermetallics. In the case of Cr, Be seems to be incorporated into the Cr layer. PIXE analysis has however been unable to characterize Al-based interlayers (Z=13, close to the lower PIXE sensibility limit) and emphasizes one limitation of Ion Beam Analysis methods for lighter metals, justifying the use of other

  14. Long-term results after lung transplantation using organs from circulatory death donors: a propensity score-matched analysis†.

    Science.gov (United States)

    Sabashnikov, Anton; Patil, Nikhil P; Popov, Aron-Frederik; Soresi, Simona; Zych, Bartlomiej; Weymann, Alexander; Mohite, Prashant N; García Sáez, Diana; Zeriouh, Mohamed; Wahlers, Thorsten; Choi, Yeong-Hoon; Wippermann, Jens; Wittwer, Thorsten; De Robertis, Fabio; Bahrami, Toufan; Amrani, Mohamed; Simon, André R

    2016-01-01

    Due to organ shortage in lung transplantation (LTx), donation after circulatory death (DCD) has been implemented in several countries, contributing to an increasing number of organs transplanted. We sought to assess long-term outcomes after LTx with organs procured following circulatory death in comparison with those obtained from donors after brain death (DBD). Between January 2007 and November 2013, 302 LTxs were performed in our institution, whereby 60 (19.9%) organs were retrieved from DCD donors. We performed propensity score matching (DCD:DBD = 1:2) based on preoperative donor and recipient factors that were significantly different in univariate analysis. After propensity matching, there were no statistically significant differences between the groups in terms of demographics and preoperative donor and recipient characteristics. There were no significant differences regarding intraoperative variables and total ischaemic time. Patients from the DCD group had significantly higher incidence of primary graft dysfunction grade 3 at the end of the procedure (P = 0.014), and significantly lower pO2/FiO2 ratio during the first 24 h after the procedure (P = 0.018). There was a trend towards higher incidence of the need for postoperative extracorporeal life support in the DCD group. Other postoperative characteristics were comparable. While the overall cumulative survival was not significantly different, the DCD group had significantly poorer results in terms of bronchiolitis obliterans syndrome (BOS)-free survival in the long-term follow-up. Long-term results after LTx with organs procured following DCD are in general comparable with those obtained after DBD LTx. However, patients transplanted using organs from DCD donors have a predisposition for development of BOS in the longer follow-up. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Circulatory and Renal Consequences of Pregnancy in Diabetic NOD Mice

    Science.gov (United States)

    Burke, S.D.; Barrette, V.F.; David, S.; Khankin, E. V.; Adams, M.A.; Croy, B.A.

    2011-01-01

    Objectives Women with diabetes have elevated gestational risks for severe hemodynamic complications, including preeclampsia in mid- to late pregnancy. This study employed continuous, chronic radiotelemetry to compare the hemodynamic patterns in non-obese diabetic (NOD) mice who were overtly diabetic or normoglycemic throughout gestation. We hypothesized that overtly diabetic, pregnant NOD mice would develop gestational hypertension and provide understanding of mechanisms in progression of this pathology. Study Design Telemeter-implanted, age-matched NOD females with and without diabetes were assessed for six hemodynamic parameters (mean, systolic, diastolic, pulse pressures, heart rate and activity) prior to mating, over pregnancy and over a 72 hr post-partum interval. Urinalysis, serum biochemistry and renal histopathology were also conducted. Results Pregnant, normoglycemic NOD mice had a hemodynamic profile similar to other inbred strains, despite insulitis. This pattern was characterized by an interval of pre-implantation stability, post implantation decline in arterial pressure to mid gestation, and then a rebound to pre-pregnancy baseline during later gestation. Overtly diabetic NOD mice had a blood pressure profile that was normal until mid-gestation then become mildly hypotensive (−7mmHg, Ppost-partum (−10% pre-pregnancy pressure and HR, P<0.05). Conclusions Pregnancy accelerates circulatory and renal pathologies in overtly diabetic NOD mice and is characterized by depressed arterial pressure from mid-gestation and birth of growth 45 restricted offspring. PMID:22014504

  16. Characterization of ITER tungsten qualification mock-ups exposed to high cyclic thermal loads

    Energy Technology Data Exchange (ETDEWEB)

    Pintsuk, Gerald, E-mail: g.pintsuk@fz-juelich.de [Forschungszentrum Jülich GmbH, D-52425 Jülich (Germany); Bednarek, Maja; Gavila, Pierre [Fusion for Energy, E-08019 Barcelona (Spain); Gerzoskovitz, Stefan [Plansee SE, Innovation Services, 6600 Reutte (Austria); Linke, Jochen [Forschungszentrum Jülich GmbH, D-52425 Jülich (Germany); Lorenzetto, Patrick; Riccardi, Bruno [Fusion for Energy, E-08019 Barcelona (Spain); Escourbiac, Frederic [ITER Organization, Route de Vinon sur Verdon, CS 90 046, 13067 Saint Paul lez Durance (France)

    2015-10-15

    Highlights: • Mechanical deformation of CuCrZr in case a thermal barrier layer has been formed due to impurity content in the cooling water. • Crack formation at the W/Cu interface starting at the block edge. • Porosity formation in the pure Cu interlayer. • Microstructural changes in tungsten down to the W/Cu interface, which indicates also high temperatures for the pure Cu interlayer. • Macrocrack formation in tungsten which is assumed to be ductile at the initiation point and brittle when proceeding toward the cooling tube. - Abstract: High heat flux tested small-scale tungsten monoblock mock-ups (5000 cycles at 10 MW/m{sup 2} and up to 1000 cycles at 20 MW/m{sup 2}) manufactured by Plansee and Ansaldo were characterized by metallographic means. Therein, the macrocrack formation and propagation in tungsten, its recrystallization behavior and the surface response to different heat load facilities were investigated. Furthermore, debonding at the W/Cu interface, void formation in the soft copper interlayer and microcrack formation at the inner surface of the CuCrZr cooling tube were found.

  17. Designs for mechanical circulatory support device studies.

    Science.gov (United States)

    Neaton, James D; Normand, Sharon-Lise; Gelijns, Annetine; Starling, Randall C; Mann, Douglas L; Konstam, Marvin A

    2007-02-01

    There is increased interest in mechanical circulatory support devices (MCSDs), such as implantable left ventricular assist devices (LVADs), as "destination" therapy for patients with advanced heart failure. Because patient availability to evaluate these devices is limited and randomized trials have been slow in enrolling patients, a workshop was convened to consider designs for MCSD development including alternatives to randomized trials. A workshop was jointly planned by the Heart Failure Society of America and the US Food and Drug Administration and was convened in March 2006. One of the panels was asked to review different designs for evaluating new MCSDs. Randomized trials have many advantages over studies with no controls or with nonrandomized concurrent or historical controls. These advantages include the elimination of bias in the assignment of treatments and the balancing, on average, of known and unknown baseline covariates that influence response. These advantages of randomization are particularly important for studies in which the treatments may not differ from one another by a large amount (eg, a head-to-head study of an approved LVAD with a new LVAD). However, researchers have found it difficult to recruit patients to randomized studies because the number of clinical sites that can carry out the studies is not large. Also, there is a reluctance to randomize patients when the control device is considered technologically inferior. Thus ways of improving the design of randomized trials were discussed, and the advantages and disadvantages of alternative designs were considered. The panel concluded that designs should include a randomized component. Randomized designs might be improved by allowing the control device to be chosen before randomization, by first conducting smaller vanguard studies, and by allowing crossovers in trials with optimal medical management controls. With use of data from completed trials, other databases, and registries, alternative

  18. Fabrication of full-size mock-up for 10° section of ITER vacuum vessel thermal shield

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dong Kwon [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Nam, Kwanwoo, E-mail: kwnam@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Kang, Kyoung-O; Noh, Chang Hyun; Chung, Wooho [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Lim, Kisuk; Kang, Youngkil [SFA Engineering Corp., Asan-si, Chungcheongnam-do 336-873 (Korea, Republic of); Hamlyn-Harris, Craig; Her, Namil; Robby, Hicks [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2015-10-15

    In this paper, a full-scale prototype fabrication for vacuum vessel thermal shield (VVTS) of ITER tokamak is described and test results are reported. All the manufacturing processes except for silver coating were performed in the fabrication of 10° section of VVTS. Pre-qualification test was conducted to compare the vertical and the horizontal welding positions. After shell welding, shell distortion was measured and adjusted. Shell thickness change was also measured after buffing process. Specially, VVTS ports need large bending and complex welding of shell and flange. Bending method for the complex and long cooling tube layout especially for the VVTS ports was developed in detail. Dimensional inspection of the fabricated mock-up was performed with a 3D laser scanner and the scanning data was analyzed.

  19. Is all sexual harassment viewed the same? Mock juror decisions in same- and cross-gender cases.

    Science.gov (United States)

    Wayne, J H; Riordan, C M; Thomas, K M

    2001-04-01

    Given recent court decisions, there is a need to investigate less common forms of sexual harassment, including women harassing men and same-gender harassment. The present study was a 2 (harasser gender) x 2 (target gender) x 2 (participant gender) factorial design in which 408 mock jurors made decisions in a hostile work environment case. Women harassing men were more likely to be found guilty than were men harassing women, and harassers in same-gender cases were more likely to be found guilty and were perceived more negatively than harassers in cross-gender cases. Participant gender differences were found in cross-gender, but not same-gender, conditions. Results suggest that the gender composition of the harasser and target may be an extralegal factor influencing managerial and juror decision making.

  20. Is gender policy related to the gender gap in external cause and circulatory disease mortality? A mixed effects model of 22 OECD countries 1973–2008

    Directory of Open Access Journals (Sweden)

    Backhans Mona

    2012-11-01

    Full Text Available Abstract Background Gender differences in mortality vary widely between countries and over time, but few studies have examined predictors of these variations, apart from smoking. The aim of this study is to investigate the link between gender policy and the gender gap in cause-specific mortality, adjusted for economic factors and health behaviours. Methods 22 OECD countries were followed 1973–2008 and the outcomes were gender gaps in external cause and circulatory disease mortality. A previously found country cluster solution was used, which includes indicators on taxes, parental leave, pensions, social insurances and social services in kind. Male breadwinner countries were made reference group and compared to earner-carer, compensatory breadwinner, and universal citizen countries. Specific policies were also analysed. Mixed effect models were used, where years were the level 1-units, and countries were the level 2-units. Results Both the earner-carer cluster (ns after adjustment for GDP and policies characteristic of that cluster are associated with smaller gender differences in external causes, particularly due to an association with increased female mortality. Cluster differences in the gender gap in circulatory disease mortality are the result of a larger relative decrease of male mortality in the compensatory breadwinner cluster and the earner-carer cluster. Policies characteristic of those clusters were however generally related to increased mortality. Conclusion Results for external cause mortality are in concordance with the hypothesis that women become more exposed to risks of accident and violence when they are economically more active. For circulatory disease mortality, results differ depending on approach – cluster or indicator. Whether cluster differences not explained by specific policies reflect other welfare policies or unrelated societal trends is an open question. Recommendations for further studies are made.