WorldWideScience

Sample records for mobility increment spectrometer

  1. Interfacing an aspiration ion mobility spectrometer to a triple quadrupole mass spectrometer

    International Nuclear Information System (INIS)

    Adamov, Alexey; Viidanoja, Jyrki; Kaerpaenoja, Esko; Paakkanen, Heikki; Ketola, Raimo A.; Kostiainen, Risto; Sysoev, Alexey; Kotiaho, Tapio

    2007-01-01

    This article presents the combination of an aspiration-type ion mobility spectrometer with a mass spectrometer. The interface between the aspiration ion mobility spectrometer and the mass spectrometer was designed to allow for quick mounting of the aspiration ion mobility spectrometer onto a Sciex API-300 triple quadrupole mass spectrometer. The developed instrumentation is used for gathering fundamental information on aspiration ion mobility spectrometry. Performance of the instrument is demonstrated using 2,6-di-tert-butyl pyridine and dimethyl methylphosphonate

  2. Ion mobility spectrometer / mass spectrometer (IMS-MS).

    Energy Technology Data Exchange (ETDEWEB)

    Hunka Deborah Elaine; Austin, Daniel E.

    2005-07-01

    The use of Ion Mobility Spectrometry (IMS) in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400). Combining Ion Mobility Spectrometry (IMS) with Mass Spectrometry (MS) is described. The IMS-MS combination overcomes several limitations present in simple IMS systems. Ion mobility alone is insufficient to identify an unknown chemical agent. Collision cross section, upon which mobility is based, is not sufficiently unique or predictable a priori to be able to make a confident peak assignment unless the compounds present are already identified. Molecular mass, on the other hand, is much more readily interpreted and related to compounds. For a given compound, the molecular mass can be determined using a pocket calculator (or in one's head) while a reasonable value of the cross-section might require hours of computation time. Thus a mass spectrum provides chemical specificity and identity not accessible in the mobility spectrum alone. In addition, several advanced mass spectrometric methods, such as tandem MS, have been extensively developed for the purpose of molecular identification. With an appropriate mass spectrometer connected to an ion mobility spectrometer, these advanced identification methods become available, providing greater characterization capability.

  3. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  4. The circular electrical mobility spectrometer; theory, performances and applications

    International Nuclear Information System (INIS)

    Mesbah, Boualem

    1995-04-01

    A new type of electrical mobility spectrometer (S.M.E.C.) has been designed in the Service d'Etudes et de Recherches en Aerocontamination et en Confinement (CEA) laboratories. It differs from classical electrical mobility spectrometers in its plan circular geometry and its radial flow. This gives some advantages and the possibility of new applications. The theories that we derive for the different versions of this device are confirmed by experimental results obtained using aerosol particles with known electrical mobility. The S.M.E.C's performances are tested for several applications: - controlled surface contamination, - monodisperse aerosol production, - fine and ultrafine aerosol sizing. (author) [fr

  5. Using a portable ion mobility spectrometer to screen dietary supplements for sibutramine.

    Science.gov (United States)

    Dunn, Jamie D; Gryniewicz-Ruzicka, Connie M; Kauffman, John F; Westenberger, Benjamin J; Buhse, Lucinda F

    2011-02-20

    In response to recent incidents of undeclared sibutramine, an appetite suppressant found in dietary supplements, we developed a method to detect sibutramine using hand-held ion mobility spectrometers with an analysis time of 15 s. Ion mobility spectrometry is a high-throughput and sensitive technique that has been used for illicit drug, explosive, volatile organic compound and chemical warfare detection. We evaluated a hand-held ion mobility spectrometer as a tool for the analysis of supplement extracts containing sibutramine. The overall instrumental limit of detection of five portable ion mobility spectrometers was 2 ng of sibutramine HCl. When sample extractions containing 30 ng/μl or greater of sibutramine were analyzed, saturation of the ionization chamber of the spectrometer occurred and the instrument required more than three cleaning cycles to remove the drug. Hence, supplement samples suspected of containing sibutramine should be prepared at concentrations of 2-20 ng/μl. To obtain this target concentration range for products containing unknown amounts of sibutramine, we provided a simple sample preparation procedure, allowing the U.S. Food and Drug Administration or other agencies to screen products using the portable ion mobility spectrometer. Published by Elsevier B.V.

  6. Miniaturized NIR scanning grating spectrometer for use in mobile phones

    Science.gov (United States)

    Knobbe, Jens; Pügner, Tino; Grüger, Heinrich

    2016-05-01

    An extremely miniaturized scanning grating spectrometer at the size of a sugar cube has been developed at Fraunhofer IPMS. To meet the requirements for the integration into a mobile phone a new system approach has been pursued. The key component within the system is a silicon-based deflectable diffraction grating with an integrated driving mechanism. A first sample of the new spectrometer was built and characterized. It was found to have a spectral range from 950 nm to 1900 nm at a resolution of 10 nm. The results show that the performance of the new MEMS spectrometer is in good agreement with the requirements for mobile phone integration.

  7. Programmable ion mobility spectrometer: Time resolution improvement and ion counter comparison

    International Nuclear Information System (INIS)

    Harrison, R.G.; Wilding, R.J.

    2005-01-01

    Atmospheric ion mobility spectrometers operating on the aspirated electrode principle require switching of a bias voltage to select ions of different mobility. The ion spectrum can be obtained by sweeping across a set of bias voltages. If rapid temporal changes in atmospheric ion spectra are to be measured, however, such as for a balloon-carried instrument, the sweep time across the ion spectrum must be kept short. As bias voltage steps can generate saturation in the mobility spectrometer's electrometer amplifier, the electrometer recovery time limits the ion mobility spectrum sweep rate. Here, active compensation of the charge injected at a bias voltage step is used to reduce the saturation time. Further, the optimal setting of the charge compensation circuitry provides a determination of the system capacitance, a necessary calibration parameter for absolute measurements. Using laboratory air, hourly variations in ion concentrations and air conductivity found using the voltage switching system were similar to those obtained with a traditional ion counter operating at a single mobility: ion growth, however, could only be detected using the ion spectrometer

  8. Ion mobility spectrometer for online monitoring of trace compounds

    International Nuclear Information System (INIS)

    Li, F.; Xie, Z.; Schmidt, H.; Sielemann, S.; Baumbach, J.I.

    2002-01-01

    The principle, character and developments of the instrumentation of ion mobility spectrometry are reviewed. The application of ion mobility spectrometers in monitoring chemical warfare agents, explosives, drugs, environmental hazardous compounds and industrial process control are discussed. Process applications with respect to miniaturization of the instrument are presented

  9. Calibration method for ion mobility spectrometer

    International Nuclear Information System (INIS)

    Vasiliev, Valery

    2011-01-01

    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives detection. This method is most suitable for use in portable detectors, due to the small weight, small size parameters and low power consumption.

  10. Application of ion mobility spectrometer for rapid drug detection

    International Nuclear Information System (INIS)

    Zhu Xuemei; Zheng Jian; Lv Yongjie; Chen Yangqin

    2007-01-01

    A 63 Ni source-based high resolution ion mobility spectrometer (IMS) was developed and applied to drug detection. The drugs included opium, morphine, heroin, methamphetamine, MDMA, MDEA, ketamine and cannabis. Their ion mobility spectra were acquired, ion types were derived and reduced mobilities were calculated, which are in good agreement with the data reported in literatures. The results indicate that the IMS can detect effectively a variety of drugs, especially for the amphetamine derivatives. And the reduced mobility standard database of drugs was established. (authors)

  11. Application of ion mobility spectrometer for rapid drug detection

    Energy Technology Data Exchange (ETDEWEB)

    Xuemei, Zhu; Jian, Zheng [The Third Research Inst. of Ministry of Public Security, Shanghai (China); Yongjie, Lv; Yangqin, Chen [Department of Physics, Key Laboratory of Optical and Magnetic Resonance Spectroscopy, East China Normal Univ., Shanghai (China)

    2007-10-15

    A {sup 63}Ni source-based high resolution ion mobility spectrometer (IMS) was developed and applied to drug detection. The drugs included opium, morphine, heroin, methamphetamine, MDMA, MDEA, ketamine and cannabis. Their ion mobility spectra were acquired, ion types were derived and reduced mobilities were calculated, which are in good agreement with the data reported in literatures. The results indicate that the IMS can detect effectively a variety of drugs, especially for the amphetamine derivatives. And the reduced mobility standard database of drugs was established. (authors)

  12. Ion mobility analyzer - quadrupole mass spectrometer system design

    International Nuclear Information System (INIS)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina; Bocos-Bintintan, V

    2009-01-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  13. Ion mobility analyzer - quadrupole mass spectrometer system design

    Energy Technology Data Exchange (ETDEWEB)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Bocos-Bintintan, V, E-mail: cornel.cuna@itim-cj.r [Babes-Bolyai University, Faculty of Environmental Sciences, 3 Fantanele, 400294 Cluj Napoca (Romania)

    2009-08-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  14. Mobile phone based mini-spectrometer for rapid screening of skin cancer

    Science.gov (United States)

    Das, Anshuman; Swedish, Tristan; Wahi, Akshat; Moufarrej, Mira; Noland, Marie; Gurry, Thomas; Aranda-Michel, Edgar; Aksel, Deniz; Wagh, Sneha; Sadashivaiah, Vijay; Zhang, Xu; Raskar, Ramesh

    2015-06-01

    We demonstrate a highly sensitive mobile phone based spectrometer that has potential to detect cancerous skin lesions in a rapid, non-invasive manner. Earlier reports of low cost spectrometers utilize the camera of the mobile phone to image the field after moving through a diffraction grating. These approaches are inherently limited by the closed nature of mobile phone image sensors and built in optical elements. The system presented uses a novel integrated grating and sensor that is compact, accurate and calibrated. Resolutions of about 10 nm can be achieved. Additionally, UV and visible LED excitation sources are built into the device. Data collection and analysis is simplified using the wireless interfaces and logical control on the smart phone. Furthermore, by utilizing an external sensor, the mobile phone camera can be used in conjunction with spectral measurements. We are exploring ways to use this device to measure endogenous fluorescence of skin in order to distinguish cancerous from non-cancerous lesions with a mobile phone based dermatoscope.

  15. Mobile environment for an emission spectrometer

    Science.gov (United States)

    Radziak, Kamil; Litwin, Dariusz; Galas, Jacek; Tyburska-Staniewska, Anna; Ramsza, Andrzej

    2017-08-01

    The paper describes a mobile application to be used in a chemical analytical laboratory. The program running under the control of Android operating system allows for preview of measurements recorded by the emission spectrometer. Another part of the application monitors operational and configuration parameters of the device in real time. The first part of this paper includes an overview of the atomic spectrometry. The second part contains a description of the application and its further potential development direction.

  16. Mobility Spectrometer Studies on Hydrazine and Ammonia Detection

    Science.gov (United States)

    Niu, William; Eiceman, Gary; Szumlas, Andrew; Lewis, John

    2011-01-01

    An airborne vapor analyzer for detecting sub- to low- parts-per-million (ppm) hydrazine in the presence of higher concentration levels of ammonia has been under development for the Orion program. The detector is based on ambient pressure ionization and ion mobility characterization. The detector encompasses: 1) a membrane inlet to exclude particulate and aerosols from the analyzer inlet; 2) a method to separate hydrazine from ammonia which would otherwise lead to loss of calibration and quantitative accuracy for the hydrazine determination; and 3) response and quantitative determinations for both hydrazine and ammonia. Laboratory studies were made to explore some of these features including mobility measurements mindful of power, size, and weight issues. The study recommended the use of a mobility spectrometer of traditional design with a reagent gas and equipped with an inlet transfer line of bonded phase fused silica tube. The inlet transfer line provided gas phase separation of neutrals of ammonia from hydrazine at 50 C simplifying significantly the ionization chemistry that underlies response in a mobility spectrometer. Performance of the analyzer was acceptable between ranges of 30 to 80 C for both the pre-fractionation column and the drift tube. An inlet comprised of a combined membrane with valve-less injector allowed high speed quantitative determination of ammonia and hydrazine without cross reactivity from common metabolites such as alcohols, esters, and aldehydes. Preliminary test results and some of the design features are discussed.

  17. TSI Model 3936 Scanning Mobility Particle Spectrometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Kuang, C. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-02-01

    The Model 3936 Scanning Mobility Particle Spectrometer (SMPS) measures the size distribution of aerosols ranging from 10 nm up to 1000 nm. The SMPS uses a bipolar aerosol charger to keep particles within a known charge distribution. Charged particles are classified according to their electrical mobility, using a long-column differential mobility analyzer (DMA). Particle concentration is measured with a condensation particle counter (CPC). The SMPS is well-suited for applications including: nanoparticle research, atmospheric aerosol studies, pollution studies, smog chamber evaluations, engine exhaust and combustion studies, materials synthesis, filter efficiency testing, nucleation/condensation studies, and rapidly changing aerosol systems.

  18. Ion Mobility Spectrometer Field Test

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Nicholas [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; McLain, Derek [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division; Steeb, Jennifer [Argonne National Lab. (ANL), Argonne, IL (United States). Nuclear Engineering Division

    2017-12-20

    The Morpho Saffran Itemizer 4DX Ion Mobility Spectrometer previously used to detect uranium signatures in FY16 was used at the former New Brunswick Facility, a past uranium facility located on site at Argonne National Laboratory. This facility was chosen in an attempt to detect safeguards relevant signatures and has a history of processing uranium at various enrichments, chemical forms, and purities; various chemicals such as nitric acid, uranium fluorides, phosphates and metals are present at various levels. Several laboratories were sampled for signatures of nuclear activities around the laboratory. All of the surfaces that were surveyed were below background levels of the radioanalytical instrumentation and determined to be radiologically clean.

  19. Influence of the coupling between an atmospheric pressure ion mobility spectrometer and the low pressure ion inlet of a mass spectrometer on the mobility measurement

    Directory of Open Access Journals (Sweden)

    Gunzer Frank

    2016-01-01

    Full Text Available Ion mobility spectrometers (IMS are versatile gas analyzers. Due to their small size and robustness, combined with a very high sensitivity, they are often used in gas sensing applications such as environmental monitoring. In order to improve the selectivity, they are typically combined with a mass spectrometer (MS. Since IMS works at atmospheric pressure, and MS works at vacuum, a special interface reducing the pressure over normally two stages has to be used. In this paper the influence of this coupling of different pressure areas on the IMS signal will be analyzed with help of finite elements method simulations.

  20. Application of an ion mobility spectrometer based on virtual instrument technology

    International Nuclear Information System (INIS)

    Fu Shihong; Wei Yongbo; Jiang Dazhen

    2008-01-01

    This paper presents the application of virtual instrument technology on an ion mobility spectrometer (IMS). By designing the data acquisition and processing system of IMS on LabVIEW platform, the ability of signal processing and real time measurement in practice has been improved. (authors)

  1. A mobility spectrometer for measurement of initial properties of 218Po

    International Nuclear Information System (INIS)

    Strydom, R.; Leuschner, A.H.; Stoker, P.H.

    1990-01-01

    This paper describes the development of a mobility spectrometer with adequate resolution to study the clustering processes (in ion-induced nucleation) that may occur. The first results of measurements of pure water clustering around 218 Po ions using the spectrometer are presented. It is found that the radius of the ion increases with relative humidity. The results are compared with predictions of two representations of the clustering theory. The theory qualitatively explains the results obtained, but there are considerable differences between the experimental measurements and the theoretical predictions, as well as between the two representations of the theory. (author)

  2. Ion mobility spectrometer with virtual aperture grid

    Science.gov (United States)

    Pfeifer, Kent B.; Rumpf, Arthur N.

    2010-11-23

    An ion mobility spectrometer does not require a physical aperture grid to prevent premature ion detector response. The last electrodes adjacent to the ion collector (typically the last four or five) have an electrode pitch that is less than the width of the ion swarm and each of the adjacent electrodes is connected to a source of free charge, thereby providing a virtual aperture grid at the end of the drift region that shields the ion collector from the mirror current of the approaching ion swarm. The virtual aperture grid is less complex in assembly and function and is less sensitive to vibrations than the physical aperture grid.

  3. Toward an Intelligent Ion Mobility Spectrometer (IMS)

    International Nuclear Information System (INIS)

    McJunkin, Timothy R.; Scott, Jill R.; Miller, Carla J.

    2003-01-01

    The ultimate goal is to design and build a very smart ion mobility spectrometer (IMS) that can operate autonomously. To accomplish this, software capable of interpreting spectra so that it can be used in control loops for data interpretation as well as adjusting instrument parameters is being developed. Fuzzy logic and fuzzy numbers are used in this IMS spectra classification scheme. Fuzzy logic provides a straight forward method for developing a classification/detection system, whenever rules for classifying the spectra can be described linguistically. Instead of using 'max' and 'min' values, the product of the truth values is used to determine class membership. Using the product allows rule-bases that utilize the AND function to allow each condition to discount truth value in determining membership, while rule-bases with an OR function are allowed to accumulate membership. Fuzzy numbers allow encapsulation of the uncertainties due to ion mobility peak widths as well as measured instrumental parameters, such as pressure and temperature. Associating a peak with a value of uncertainty, in addition to making adjustments to the mobility calculation based on variations in measured parameters, enables unexpected shifts to be more reliably detected and accounted for; thereby, reducing the opportunity for 'false negative' results. The measure of uncertainty is anticipated to serve the additional purpose of diagnosing the operational conditions of the IMS instrument.

  4. Direct classification of olive oils by using two types of ion mobility spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Garrido-Delgado, Rocio [Department of Analytical Chemistry, University of Cordoba, Annex C3 Building, Campus of Rabanales, E-14071 Cordoba (Spain); Mercader-Trejo, Flora [Department of Analytical Chemistry, University of Cordoba, Annex C3 Building, Campus of Rabanales, E-14071 Cordoba (Spain); Metrologia de Materiales, Centro Nacional de Metrologia, km. 4.5 Carretera a Los Cues, El Marques, Queretaro (Mexico); Sielemann, Stefanie; Bruyn, Wolfgang de [G.A.S. Gesellschaft fuer analytische Sensorsysteme mbH, BioMedizinZentrumDortmund, Otto-Hahn-Str. 15, 44227 Dortmund (Germany); Arce, Lourdes [Department of Analytical Chemistry, University of Cordoba, Annex C3 Building, Campus of Rabanales, E-14071 Cordoba (Spain); Valcarcel, Miguel, E-mail: qa1meobj@uco.es [Department of Analytical Chemistry, University of Cordoba, Annex C3 Building, Campus of Rabanales, E-14071 Cordoba (Spain)

    2011-06-24

    Graphical abstract: Highlights: > We explore the use of Ion Mobility Spectrometers for classification of olive oils. > Three types of olive oils were analyzed with both devices coupled to headspace system. > The ion mobility data were processed using chemometric to obtain global information. > The classification rate was better using tritium source and separation step prior IMS. - Abstract: In this work, we explored the use of an Ion Mobility Spectrometry (IMS) device with an ultraviolet (UV) source, and of a Gas Chromatographic (GC) column coupled to an IM Spectrometer with a tritium source, for the discrimination of three grades of olive oil, namely: extra virgin olive oil (EVOO), olive oil (OO) and pomace olive oil (POO). The three types of oil were analyzed with both equipment combinations as coupled to a headspace system and the obtained ion mobility data were consecutively processed with various chemometric tools. The classification rate for an independent validation set was 86.1% (confidence interval at 95% [83.4%, 88.5%]) with an UV-IMS and 100% (confidence interval at 95% [87%, 100%]) using a GC-IMS system. The classification rate was improved by using a more suitable ionization source and a pre-separation step prior to the IM analysis.

  5. Direct classification of olive oils by using two types of ion mobility spectrometers

    International Nuclear Information System (INIS)

    Garrido-Delgado, Rocio; Mercader-Trejo, Flora; Sielemann, Stefanie; Bruyn, Wolfgang de; Arce, Lourdes; Valcarcel, Miguel

    2011-01-01

    Graphical abstract: Highlights: → We explore the use of Ion Mobility Spectrometers for classification of olive oils. → Three types of olive oils were analyzed with both devices coupled to headspace system. → The ion mobility data were processed using chemometric to obtain global information. → The classification rate was better using tritium source and separation step prior IMS. - Abstract: In this work, we explored the use of an Ion Mobility Spectrometry (IMS) device with an ultraviolet (UV) source, and of a Gas Chromatographic (GC) column coupled to an IM Spectrometer with a tritium source, for the discrimination of three grades of olive oil, namely: extra virgin olive oil (EVOO), olive oil (OO) and pomace olive oil (POO). The three types of oil were analyzed with both equipment combinations as coupled to a headspace system and the obtained ion mobility data were consecutively processed with various chemometric tools. The classification rate for an independent validation set was 86.1% (confidence interval at 95% [83.4%, 88.5%]) with an UV-IMS and 100% (confidence interval at 95% [87%, 100%]) using a GC-IMS system. The classification rate was improved by using a more suitable ionization source and a pre-separation step prior to the IM analysis.

  6. A Microfluidics-HPLC/Differential Mobility Spectrometer Macromolecular Detection System for Human and Robotic Missions

    Science.gov (United States)

    Coy, S. L.; Killeen, K.; Han, J.; Eiceman, G. A.; Kanik, I.; Kidd, R. D.

    2011-01-01

    Our goal is to develop a unique, miniaturized, solute analyzer based on microfluidics technology. The analyzer consists of an integrated microfluidics High Performance Liquid Chromatographic chip / Differential Mobility Spectrometer (?HPLCchip/ DMS) detection system

  7. Distributed Water Pollution Source Localization with Mobile UV-Visible Spectrometer Probes in Wireless Sensor Networks.

    Science.gov (United States)

    Ma, Junjie; Meng, Fansheng; Zhou, Yuexi; Wang, Yeyao; Shi, Ping

    2018-02-16

    Pollution accidents that occur in surface waters, especially in drinking water source areas, greatly threaten the urban water supply system. During water pollution source localization, there are complicated pollutant spreading conditions and pollutant concentrations vary in a wide range. This paper provides a scalable total solution, investigating a distributed localization method in wireless sensor networks equipped with mobile ultraviolet-visible (UV-visible) spectrometer probes. A wireless sensor network is defined for water quality monitoring, where unmanned surface vehicles and buoys serve as mobile and stationary nodes, respectively. Both types of nodes carry UV-visible spectrometer probes to acquire in-situ multiple water quality parameter measurements, in which a self-adaptive optical path mechanism is designed to flexibly adjust the measurement range. A novel distributed algorithm, called Dual-PSO, is proposed to search for the water pollution source, where one particle swarm optimization (PSO) procedure computes the water quality multi-parameter measurements on each node, utilizing UV-visible absorption spectra, and another one finds the global solution of the pollution source position, regarding mobile nodes as particles. Besides, this algorithm uses entropy to dynamically recognize the most sensitive parameter during searching. Experimental results demonstrate that online multi-parameter monitoring of a drinking water source area with a wide dynamic range is achieved by this wireless sensor network and water pollution sources are localized efficiently with low-cost mobile node paths.

  8. Ion mobility sensor system

    Science.gov (United States)

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  9. The simulation of pulsed heater for a sampling system for the ion mobility spectrometer

    International Nuclear Information System (INIS)

    Malkin, Evgeniy

    2011-01-01

    The development of the sampling device with pulsed heating of the intermediate carrier for ion mobility spectrometer is described in this article. Numerical simulation of a pulse heater structure of is presented. The design of the sampling device using a pulsed heating of the intermediate carrier is developed. Experimental results of approval of the sampling device are presented.

  10. The ion mobility spectrometer for high explosive vapor detection

    International Nuclear Information System (INIS)

    Cohen, M.J.; Stimac, R.M.; Wernlund, R.F.

    1984-01-01

    The Phemto-Chem /SUP R/ Model 100 Ion Mobility Spectrometer (IMS) operates in air and measures a number of explosive vapors at levels as low as partsper-trillion in seconds. The theory and operation of this instrument is discussed. The IMS inhales the vapor sample in a current of air and generates characteristic ions which are separated by time-of -ion drift in the atmospheric pressure gas. Quantitative results, using a dilution tunnel and standard signal generator with TNT, nitroglycerine, ethylene glycol dinitrate, cyclohexanone, methylamine, octafluoronaphthalene and hexafluorobenzene, are given. Rapid sample treatment with sample concentrations, microprocessor signal readout and chemical identification, offer a realistic opportunity of rapid explosive vapor detection at levels down to 10 -14 parts by volume in air

  11. Distributed Water Pollution Source Localization with Mobile UV-Visible Spectrometer Probes in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Junjie Ma

    2018-02-01

    Full Text Available Pollution accidents that occur in surface waters, especially in drinking water source areas, greatly threaten the urban water supply system. During water pollution source localization, there are complicated pollutant spreading conditions and pollutant concentrations vary in a wide range. This paper provides a scalable total solution, investigating a distributed localization method in wireless sensor networks equipped with mobile ultraviolet-visible (UV-visible spectrometer probes. A wireless sensor network is defined for water quality monitoring, where unmanned surface vehicles and buoys serve as mobile and stationary nodes, respectively. Both types of nodes carry UV-visible spectrometer probes to acquire in-situ multiple water quality parameter measurements, in which a self-adaptive optical path mechanism is designed to flexibly adjust the measurement range. A novel distributed algorithm, called Dual-PSO, is proposed to search for the water pollution source, where one particle swarm optimization (PSO procedure computes the water quality multi-parameter measurements on each node, utilizing UV-visible absorption spectra, and another one finds the global solution of the pollution source position, regarding mobile nodes as particles. Besides, this algorithm uses entropy to dynamically recognize the most sensitive parameter during searching. Experimental results demonstrate that online multi-parameter monitoring of a drinking water source area with a wide dynamic range is achieved by this wireless sensor network and water pollution sources are localized efficiently with low-cost mobile node paths.

  12. Method for selective detection of explosives in mass spectrometer or ion mobility spectrometer at parts-per-quadrillion level

    Science.gov (United States)

    Ewing, Robert G.; Atkinson, David A.; Clowers, Brian H.

    2015-09-01

    A method for selective detection of volatile and non-volatile explosives in a mass spectrometer or ion mobility spectrometer at a parts-per-quadrillion level without preconcentration is disclosed. The method comprises the steps of ionizing a carrier gas with an ionization source to form reactant ions or reactant adduct ions comprising nitrate ions (NO.sub.3.sup.-); selectively reacting the reactant ions or reactant adduct ions with at least one volatile or non-volatile explosive analyte at a carrier gas pressure of at least about 100 Ton in a reaction region disposed between the ionization source and an ion detector, the reaction region having a length which provides a residence time (tr) for reactant ions therein of at least about 0.10 seconds, wherein the selective reaction yields product ions comprising reactant ions or reactant adduct ions that are selectively bound to the at least one explosive analyte when present therein; and detecting product ions with the ion detector to determine presence or absence of the at least one explosive analyte.

  13. Customized altitude-azimuth mount for a raster-scanning Fourier transform spectrometer

    Science.gov (United States)

    Durrenberger, Jed E.; Gutman, William M.; Gammill, Troy D.; Grover, Dennis H.

    1996-10-01

    Applications of the Army Research Laboratory Mobile Atmospheric Spectrometer Remote Sensing Rover required development of a customized computer-controlled mount to satisfy a variety of requirements within a limited budget. The payload was designed to operate atop a military electronics shelter mounted on a 4-wheel drive truck to be above most atmospheric ground turbulence. Pointing orientation in altitude is limited by constraints imposed by use of a liquid nitrogen detector Dewar in the spectrometer. Stepper motor drives and control system are compatible with existing custom software used with other instrumentation for controlled incremental raster stepping. The altitude axis passes close to the center of gravity of the complete payload to minimize load eccentricity and drive torque requirements. Dovetail fixture mounting enables quick service and fine adjustment of balance to minimize stepper/gearbox drive backlash through the limited orientation range in altitude. Initial applications to characterization of remote gas plumes have been successful.

  14. Determination of Benzene, Toluene, and Xylene by means of an ion mobility spectrometer device using photoionization

    Science.gov (United States)

    Leonhardt, J. W.; Bensch, H.; Berger, D.; Nolting, M.; Baumbach, J. I.

    1995-01-01

    The continuous monitoring of changes on the quality of ambient air is a field of advantage of ion mobility spectrometry. Benzene, Toluene, and Xylene are substances of special interest because of their toxicity. We present an optimized drift tube for ion mobility spectrometers, which uses photo-ionization tubes to produce the ions to be analyzed. The actual version of this drift tube has a length of 45 mm, an electric field strength established within the drift tube of about 180 V/cm and a shutter-opening-time of 400 mus. With the hydrogen tube used for ionisation a mean flux of 10(exp 12) photons/sq cm s was established for the experiments described. We discuss the results of investigations on Benzene, Toluene, and Xylene in normal used gasoline SUPER. The detection limits obtained with the ion mobility spectrometer developed in co-operation are in the range of 10 ppbv in this case. Normally, charge transfer from Benzene ions to Toluene takes place. Nevertheless the simultaneous determination in mixtures is possible by a data evaluation procedure developed for this case. The interferences found between Xylene and others are rather weak. The ion mobility spectra of different concentrations of gasoline SUPER are attached as an example for the resolution and the detection limit of the instrument developed. Resolution and sensitivity of the system are well demonstrated. A hand-held portable device produced just now is to be tested for special environmental analytical problems in some industrial and scientific laboratories in Germany.

  15. Miniature GC: Minicell ion mobility spectrometer (IMS) for astrobiology planetary missions

    Science.gov (United States)

    Kojiro, Daniel R.; Holland, Paul M.; Stimac, Robert M.; Kaye, William J.; Takeuchi, Norishige

    2006-01-01

    Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or longer mission life for stationary landers/laboratories. We describe here the development of a miniature GC - Minicell Ion Mobility Spectrometer (IMS) under development through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA's Small Business Innovative Research (SBIR) Program.

  16. Mobility particle size spectrometers: harmonization of technical standards and data structure to facilitate high quality long-term observations of atmospheric particle number size distributions

    Directory of Open Access Journals (Sweden)

    A. Wiedensohler

    2012-03-01

    Full Text Available Mobility particle size spectrometers often referred to as DMPS (Differential Mobility Particle Sizers or SMPS (Scanning Mobility Particle Sizers have found a wide range of applications in atmospheric aerosol research. However, comparability of measurements conducted world-wide is hampered by lack of generally accepted technical standards and guidelines with respect to the instrumental set-up, measurement mode, data evaluation as well as quality control. Technical standards were developed for a minimum requirement of mobility size spectrometry to perform long-term atmospheric aerosol measurements. Technical recommendations include continuous monitoring of flow rates, temperature, pressure, and relative humidity for the sheath and sample air in the differential mobility analyzer.

    We compared commercial and custom-made inversion routines to calculate the particle number size distributions from the measured electrical mobility distribution. All inversion routines are comparable within few per cent uncertainty for a given set of raw data.

    Furthermore, this work summarizes the results from several instrument intercomparison workshops conducted within the European infrastructure project EUSAAR (European Supersites for Atmospheric Aerosol Research and ACTRIS (Aerosols, Clouds, and Trace gases Research InfraStructure Network to determine present uncertainties especially of custom-built mobility particle size spectrometers. Under controlled laboratory conditions, the particle number size distributions from 20 to 200 nm determined by mobility particle size spectrometers of different design are within an uncertainty range of around ±10% after correcting internal particle losses, while below and above this size range the discrepancies increased. For particles larger than 200 nm, the uncertainty range increased to 30%, which could not be explained. The network reference mobility spectrometers with identical design agreed within ±4% in the

  17. Application Of Electronic Nose And Ion Mobility Spectrometer To Quality Control Of Spice Mixtures

    International Nuclear Information System (INIS)

    Banach, U.; Tiebe, C.; Huebert, Th.

    2009-01-01

    The aim of the paper is to demonstrate the application of electronic nose (e-nose) and ion mobility spectrometry (IMS) to quality control and to find out product adulteration of spice mixtures. Therefore the gaseous head space phase of four different spice mixtures (spices for sausages and saveloy) was differed from original composition and product adulteration. In this set of experiments metal-oxide type e-nose (KAMINA-type) has been used, and characteristic patterns of data corresponding to various complex odors of the four different spice mixtures were generated. Simultaneously an ion mobility spectrometer was coupled also to an emission chamber for the detection of gaseous components of spice mixtures. The two main methods that have been used show a clear discrimination between the original spice mixtures and product adulteration could be distinguished from original spice mixtures.

  18. A mobile gamma ray spectrometer system for nuclear hazard mapping

    CERN Document Server

    Smethurst, M A

    2000-01-01

    The Geological Survey of Norway has developed a system for mobile gamma ray spectrometer surveying suitable for use in nuclear emergencies where potentially dangerous radioactive materials have been released into the environment. The measuring system has been designed for use with different kinds of transportation platforms. These include fixed-wing aircraft, helicopters and vans. The choice of transportation platform depends on the nature of the nuclear emergency. Widespread fallout from a distant source can be mapped quickly from the air while local sources of radiation can be delineated by a car-borne system. The measuring system processes gamma ray spectra in real time. The operator of the system is therefore able to guide surveying in accordance with meaningful data values and immediately report these values to decision making The operator is presented with a number of different displays suited to different kinds of nuclear emergencies that lead to more efficient surveying. Real time processing of data m...

  19. Incremental Learning for Place Recognition in Dynamic Environments

    OpenAIRE

    Luo, Jie; Pronobis, Andrzej; Caputo, Barbara; Jensfelt, Patric

    2007-01-01

    This paper proposes a discriminative approach to template-based Vision-based place recognition is a desirable feature for an autonomous mobile system. In order to work in realistic scenarios, visual recognition algorithms should be adaptive, i.e. should be able to learn from experience and adapt continuously to changes in the environment. This paper presents a discriminative incremental learning approach to place recognition. We use a recently introduced version of the incremental SVM, which ...

  20. Performance results of a mobile high-resolution MR-TOF mass spectrometer for in-situ analytical mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lippert, Wayne; Lang, Johannes [Justus-Liebig-Universitaet Giessen (Germany); Ayet San Andres, Samuel [GSI, Darmstadt (Germany); Dickel, Timo; Geissel, Hans; Plass, Wolfgang; Scheidenberger, Christoph [Justus-Liebig-Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Yavor, Mikhail [RAS St. Petersburg (Russian Federation)

    2014-07-01

    A mobile multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been developed which provides a mass resolving power exceeding 250,000 and sub-ppm mass accuracy in a transportable format. Thus it allows resolving isobars and enables accurate determination of the composition and structure of biomolecules. Furthermore the device offers high mass resolving MS/MS capability via selective ion re-trapping and collisional-induced dissociation (CID). An atmospheric pressure interface (API) provides for routine measurements with various atmospheric ion sources. All supply electronics, DAQ and control system are mounted with the spectrometer into a single frame with a total volume of only 0.8 m{sup 3}. With the current system many applications like waste water monitoring at hot spots, mass-based classification of biomolecules and breath analysis are possible. In addition the mass spectrometer is readily scalable and can be adopted and simplified for even more specific use like in space science for instance. A characterization and first performance results are shown, and the implementation of MS/MS in combination with CID is discussed.

  1. Physiological Effects of Early Incremental Mobilization of a Patient with Acute Intracerebral and Intraventricular Hemorrhage Requiring Dual External Ventricular Drainage.

    Science.gov (United States)

    Kumble, Sowmya; Zink, Elizabeth K; Burch, Mackenzie; Deluzio, Sandra; Stevens, Robert D; Bahouth, Mona N

    2017-08-01

    Recent trials have challenged the notion that very early mobility benefits patients with acute stroke. It is unclear how cerebral autoregulatory impairments, prevalent in this population, could be affected by mobilization. The safety of mobilizing patients who have external ventricular drainage (EVD) devices for cerebrospinal fluid diversion and intracranial pressure (ICP) monitoring is another concern due to risk of device dislodgment and potential elevation in ICP. We report hemodynamic and ICP responses during progressive, device-assisted mobility interventions performed in a critically ill patient with intracerebral hemorrhage (ICH) requiring two EVDs. A 55-year-old man was admitted to the Neuroscience Critical Care Unit with an acute thalamic ICH and complex intraventricular hemorrhage requiring placement of two EVDs. Progressive mobilization was achieved using mobility technology devices. Range of motion exercises were performed initially, progressing to supine cycle ergometry followed by incremental verticalization using a tilt table. Physiological parameters were recorded before and after the interventions. All mobility interventions were completed without any adverse event or clinically detectable change in the patient's neurological state. Physiological parameters including hemodynamic variables and ICP remained within prescribed goals throughout. Progressive, device-assisted early mobilization was feasible and safe in this critically ill patient with hemorrhagic stroke when titrated by an interdisciplinary team of skilled healthcare professionals. Studies are needed to gain insight into the hemodynamic and neurophysiological responses associated with early mobility in acute stroke to identify subsets of patients who are most likely to benefit from this intervention.

  2. Noncontact measurement of electrostatic fields: Verification of modeled potentials within ion mobility spectrometer drift tube designs

    International Nuclear Information System (INIS)

    Scott, Jill R.; Tremblay, Paul L.

    2007-01-01

    The heart of an ion mobility spectrometer is the drift region where ion separation occurs. While the electrostatic potentials within a drift tube design can be modeled, no method for independently validating the electrostatic field has previously been reported. Two basic drift tube designs were modeled using SIMION 7.0 to reveal the expected electrostatic fields: (1) A traditional alternating set of electrodes and insulators and (2) a truly linear drift tube. One version of the alternating electrode/insulator drift tube and two versions of linear drift tubes were then fabricated. The stacked alternating electrodes/insulators were connected through a resistor network to generate the electrostatic gradient in the drift tube. The two linear drift tube designs consisted of two types of resistive drift tubes with one tube consisting of a resistive coating within an insulating tube and the other tube composed of resistive ferrites. The electrostatic fields within each type of drift tube were then evaluated by a noncontact method using a Kelvin-Zisman type electrostatic voltmeter and probe (results for alternative measurement methods provided in supplementary material). The experimental results were then compared with the electrostatic fields predicted by SIMION. Both the modeling and experimental measurements reveal that the electrostatic fields within a stacked ion mobility spectrometer drift tube are only pseudo-linear, while the electrostatic fields within a resistive drift tube approach perfect linearity

  3. Mid-IR spectrometer for mobile, real-time urban NO2 measurements

    Science.gov (United States)

    Morten Hundt, P.; Müller, Michael; Mangold, Markus; Tuzson, Béla; Scheidegger, Philipp; Looser, Herbert; Hüglin, Christoph; Emmenegger, Lukas

    2018-05-01

    Detailed knowledge about the urban NO2 concentration field is a key element for obtaining accurate pollution maps and individual exposure estimates. These are required for improving the understanding of the impact of ambient NO2 on human health and for related air quality measures. However, city-scale NO2 concentration maps with high spatio-temporal resolution are still lacking, mainly due to the difficulty of accurate measurement of NO2 at the required sub-ppb level precision. We contribute to close this gap through the development of a compact instrument based on mid-infrared laser absorption spectroscopy. Leveraging recent advances in infrared laser and detection technology and a novel circular absorption cell, we demonstrate the feasibility and robustness of this technique for demanding mobile applications. A fully autonomous quantum cascade laser absorption spectrometer (QCLAS) has been successfully deployed on a tram, performing long-term and real-time concentration measurements of NO2 in the city of Zurich (Switzerland). For ambient NO2 concentrations, the instrument demonstrated a precision of 0.23 ppb at one second time resolution and of 0.03 ppb after 200 s averaging. Whilst the combined uncertainty estimated for the retrieved spectroscopic values was less than 5 %, laboratory intercomparison measurements with standard CLD instruments revealed a systematic NO2 wall loss of about 10 % within the laser spectrometer. For the field campaign, the QCLAS has been referenced to a CLD using urban atmospheric air, despite the potential cross sensitivity of CLD to other nitrogen containing compounds. However, this approach allowed a direct comparison and continuous validation of the spectroscopic data to measurements at regulatory air quality monitoring (AQM) stations along the tram-line. The analysis of the recorded high-resolution time series allowed us to gain more detailed insights into the spatio-temporal concentration distribution of NO2 in an urban

  4. Note: Buffer gas temperature inhomogeneities and design of drift-tube ion mobility spectrometers: Warnings for real-world applications by non-specialists

    Science.gov (United States)

    Fernandez-Maestre, R.

    2017-09-01

    Ion mobility spectrometry (IMS) separates gas phase ions moving under an electric field according to their size-to-charge ratio. IMS is the method of choice to detect illegal drugs and explosives in customs and airports making accurate determination of reduced ion mobilities (K0) important for national security. An ion mobility spectrometer with electrospray ionization coupled to a quadrupole mass spectrometer was used to study uncertainties in buffer gas temperatures during mobility experiments. Differences up to 16°C were found in the buffer gas temperatures in different regions of the drift tube and up to 42°C between the buffer gas and the drift tube temperatures. The drift tube temperature is used as an approximation to the buffer gas temperature for the calculation of K0 because the buffer gas temperature is hard to measure. This is leading to uncertainties in the determination of K0 values. Inaccurate determination of K0 values yields false positives that delay the cargo and passengers in customs and airports. Therefore, recommendations are issued for building mobility tubes to assure a homogeneous temperature of the buffer gas. Because the temperature and other instrumental parameters are difficult to measure in IMS, chemical standards should always be used when calculating K0. The difference of 42°C between the drift tube and buffer gas temperatures found in these experiments produces a 10.5% error in the calculation of K0. This large inaccuracy in K0 shows the importance of a correct temperature measurement in IMS.

  5. A mobile device-based imaging spectrometer for environmental monitoring by attaching a lightweight small module to a commercial digital camera.

    Science.gov (United States)

    Cai, Fuhong; Lu, Wen; Shi, Wuxiong; He, Sailing

    2017-11-15

    Spatially-explicit data are essential for remote sensing of ecological phenomena. Lately, recent innovations in mobile device platforms have led to an upsurge in on-site rapid detection. For instance, CMOS chips in smart phones and digital cameras serve as excellent sensors for scientific research. In this paper, a mobile device-based imaging spectrometer module (weighing about 99 g) is developed and equipped on a Single Lens Reflex camera. Utilizing this lightweight module, as well as commonly used photographic equipment, we demonstrate its utility through a series of on-site multispectral imaging, including ocean (or lake) water-color sensing and plant reflectance measurement. Based on the experiments we obtain 3D spectral image cubes, which can be further analyzed for environmental monitoring. Moreover, our system can be applied to many kinds of cameras, e.g., aerial camera and underwater camera. Therefore, any camera can be upgraded to an imaging spectrometer with the help of our miniaturized module. We believe it has the potential to become a versatile tool for on-site investigation into many applications.

  6. Self-charging of 198Au-labeled monodisperse gold aerosols studied with a miniature electrical mobility spectrometer

    International Nuclear Information System (INIS)

    Yeh, H.C.; Newton, G.J.; Raabe, O.G.; Boor, D.R.

    1976-01-01

    Knowledge of the electrostatic character of an aerosol may be essential in assessing its potential inhalation hazard. In inhalation studies with radioactive aerosols, the aerosol charge state may change in the course of transport due to the emission of α, β or γ radiations. This paper describes an experimental study of the self-charging of 198 Au-labeled aerosols of monodisperse gold spheres by β emission. A miniature aerosol electrical mobility spectrometer, suitable for use in inhalation studies with radioactive aerosols, was developed and used in this study. This device is relatively inexpensive, easy to manufacture and its contamination by radioactive material has been minimized. Using polystyrene latex spheres, ranging in diameter from 0.176 to 1.18 μm, the spectrometer was calibrated with flow rates ranging from 400 to 4800 ml/min. Experiments with two sizes of 198 Au-labeled monodisperse gold aerosols were performed. Results indicate that the radioactivity of an aerosol can cause self-charging and affect the charge distribution. (author)

  7. Development of a portable preconcentrator/ion mobility spectrometer system for the trace detection of narcotics

    Energy Technology Data Exchange (ETDEWEB)

    Parmeter, J.E.; Custer, C.A.

    1997-08-01

    This project was supported by LDRD funding for the development and preliminary testing of a portable narcotics detection system. The system developed combines a commercial trace detector known as an ion mobility spectrometer (IMS) with a preconcentrator originally designed by Department 5848 for the collection of explosives molecules. The detector and preconcentrator were combined along with all necessary accessories onto a push cart, thus yielding a fully portable detection unit. Preliminary testing with both explosives and narcotics molecules shown that the system is operational, and that it can successfully detect drugs as marijuana, methamphetamine (speed), and cocaine based on their characteristics IMS signatures.

  8. UARS Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL data product consists of daily, 4 degree increment latitude-ordered vertical profiles of temperature...

  9. Hardware/Software Codesign in a Compact Ion Mobility Spectrometer Sensor System for Subsurface Contaminant Detection

    Directory of Open Access Journals (Sweden)

    Gribb MollyM

    2008-01-01

    Full Text Available Abstract A field-programmable-gate-array-(FPGA- based data acquisition and control system was designed in a hardware/software codesign environment using an embedded Xilinx Microblaze soft-core processor for use with a subsurface ion mobility spectrometer (IMS system, designed for detection of gaseous volatile organic compounds (VOCs. An FPGA is used to accelerate the digital signal processing algorithms and provide accurate timing and control. An embedded soft-core processor is used to ease development by implementing nontime critical portions of the design in software. The design was successfully implemented using a low-cost, off-the-shelf Xilinx Spartan-III FPGA and supporting digital and analog electronics.

  10. A mobile gamma ray spectrometer system for nuclear hazard mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark A.

    2000-12-01

    The Geological Survey of Norway has developed a system for mobile gamma ray spectrometer surveying suitable for use in nuclear emergencies where potentially dangerous radioactive materials have been released into the environment. The measuring system has been designed for use with different kinds of transportation platforms. These include fixed-wing aircraft, helicopters and vans. The choice of transportation platform depends on the nature of the nuclear emergency. Widespread fallout from a distant source can be mapped quickly from the air while local sources of radiation can be delineated by a car-borne system. The measuring system processes gamma ray spectra in real time. The operator of the system is therefore able to guide surveying in accordance with meaningful data values and immediately report these values to decision making authorities. The operator is presented with a number of different displays suited to different kinds of nuclear emergencies that lead to more efficient surveying. Real time processing of data means that the results of a survey can be delivered to decision makers immediately upon return to base. It is also possible to deliver data via a live mobile telephone link while surveying is underway. The measuring system can be adjusted to make measurements lasting between 1 second and 5 seconds. The spatial density of measuring positions depends on the duration of each measurement and the speed of travel of the measuring system. Measuring with 1 s intervals while travelling at 50 km/h in a car results in a measurement every 14 m along the road. Measuring with 1 s intervals in an aeroplane travelling at 250 km/h produces a measurement for every 70 m travelled. Eight hours surveying can produce up to 30000 measurements over a region hundreds of kilometres across. (Author)

  11. Results of the first air ion spectrometer calibration and intercomparison workshop

    Directory of Open Access Journals (Sweden)

    E. Asmi

    2009-01-01

    Full Text Available The Air Ion Spectrometer (AIS measures mobility and size distributions of atmospheric ions. The Neutral cluster and Air Ion Spectrometer (NAIS can additionally measure neutral particles. The number of the (NAIS instruments in the world is only 11. Nevertheless, they are already widely used in atmospheric ion studies, particularly related to the initial steps of new particle formation. There is no standard method applicable for calibrating the ion spectrometers in the sub-3 nm ion range. However, recent development of high resolution DMAs has enabled the size separation of small ions with good mobility resolution. For the first time, the ion spectrometers were intercompared and calibrated in a workshop, held in January–February 2008 in Helsinki, Finland. The overall goal was to experimentally determine the (NAIS transfer functions. Monomobile mobility standards, 241-Am charger ions and silver particles were generated and used as calibration aerosols. High resolution DMAs were used to size-separate the smaller (1–10 nm ions, while at bigger diameters (4–40 nm the size was selected with a HAUKE-type DMA. Negative ion mobilities were detected by (NAISs with slightly better accuracy than positive, nonetheless, both were somewhat overestimated. A linear fit of slope of one to the whole dataset of mobilities suggested that (NAISs measured the negative mobilities 1.36±0.16 times larger compared with the reference instruments. Similarly, positive mobilities were measured 1.39±0.15 times larger compared with the reference instruments. The completely monomobile mobility standards were measured with the best accuracy. The (NAIS concentrations were compared with an aerosol electrometer (AE and a condensation particle counter (CPC. At sizes below 1.5 nm (positive and 3 nm (negative the ion spectrometers detected higher concentrations while at bigger sizes they showed similar concentrations as the reference instruments. The total particle

  12. Potential for Measurement of Trace Volatile Organic Compounds in Closed Environments Using Gas Chromatograph/Differential Mobility Spectrometer

    Science.gov (United States)

    Limero, Thomas; Cheng, Patti

    2007-01-01

    For nearly 3.5 years, the Volatile Organic Analyzer (VOA) has routinely analyzed the International Space Station (ISS) atmosphere for a target list of approximately 20 volatile organic compounds (VOCs). Additionally, an early prototype of the VOA collected data aboard submarines in two separate trials. Comparison of the data collected on ISS and submarines showed a surprising similarity in the atmospheres of the two environments. Furthermore, in both cases it was demonstrated that the VOA data can detect hardware issues unrelated to crew health. Finally, it was also clear in both operations that the VOA s size and resource consumption were major disadvantages that would restrict its use in the future. The VOA showed the value of measuring VOCs in closed environments, but it had to be shrunk if it was to be considered for future operations in these environments that are characterized by cramped spaces and limited resources. The Sionex Microanalyzer is a fraction of the VOA s size and this instrument seems capable of maintaining or improving upon the analytical performance of the VOA. The two design improvements that led to a smaller, less complex instrument are the Microanalyzer s use of recirculated air as the gas chromatograph s carrier gas and a micromachined detector. Although the VOA s ion mobility spectrometer and the Microanalyzer s differential mobility spectrometer (DMS) are related detector technologies, the DMS was more amenable to micromachining. This paper will present data from the initial assessment of the Microanalyzer. The instrument was challenged with mixtures that simulated the VOCs typically detected in closed-environment atmospheres.

  13. Ignition method of corona discharge with modulation of the field in ion source of ion mobility spectrometer

    International Nuclear Information System (INIS)

    Gromov, Evgeniy

    2011-01-01

    The new method for the ignition of the corona discharge has been developed, which improves the stability of the ion mobility spectrometer and the resolution of the instrument. The system of forming a corona discharge without additional electrodes, which are used in a number of known structures for the pre-ionization, has been developed. This simplifies the design of the proposed source and an electronic control circuit. IMS technology is widely used in different civil and military fields for vapor-phase detection of explosive, narcotics, chemical warfare agents, biology molecules and so on. There are set of methods whose are used for the ionization of molecules under analysis. They are the following: radioactive ionization, ultraviolet photoionization, laser ionization, electric field ionization, corona spray ionization, electro spray ionization, roentgen ionization, and surface ionization. All these methods has their own advantages and disadvantages. A comparing of ion mobility spectra of non-polar hydrocarbons for photoionization, corona discharge ionization and 63 Ni ionization, had carried in. In our work we have investigated four types of IMS spectrometers whose use different sources for molecules under analysis ionization. They use radioactive ionization, ultraviolet photoionization, laser ionization, and roentgen ionization. The traditional explosives had investigated in experiments. In electricity, a corona discharge is an electrical discharge brought on by the ionization of a fluid surrounding a conductor, which occurs when the potential gradient (the strength of the electric field) exceeds a certain value, but conditions are insufficient to cause complete electrical breakdown or arcing.

  14. Atmospheric response to Saharan dust deduced from ECMWF reanalysis increments

    Science.gov (United States)

    Kishcha, P.; Alpert, P.; Barkan, J.; Kirchner, I.; Machenhauer, B.

    2003-04-01

    This study focuses on the atmospheric temperature response to dust deduced from a new source of data - the European Reanalysis (ERA) increments. These increments are the systematic errors of global climate models, generated in reanalysis procedure. The model errors result not only from the lack of desert dust but also from a complex combination of many kinds of model errors. Over the Sahara desert the dust radiative effect is believed to be a predominant model defect which should significantly affect the increments. This dust effect was examined by considering correlation between the increments and remotely-sensed dust. Comparisons were made between April temporal variations of the ERA analysis increments and the variations of the Total Ozone Mapping Spectrometer aerosol index (AI) between 1979 and 1993. The distinctive structure was identified in the distribution of correlation composed of three nested areas with high positive correlation (> 0.5), low correlation, and high negative correlation (Forecast(ECMWF) suggests that the PCA (NCA) corresponds mainly to anticyclonic (cyclonic) flow, negative (positive) vorticity, and downward (upward) airflow. These facts indicate an interaction between dust-forced heating /cooling and atmospheric circulation. The April correlation results are supported by the analysis of vertical distribution of dust concentration, derived from the 24-hour dust prediction system at Tel Aviv University (website: http://earth.nasa.proj.ac.il/dust/current/). For other months the analysis is more complicated because of the essential increasing of humidity along with the northward progress of the ITCZ and the significant impact on the increments.

  15. OXYGEN UPTAKE KINETICS DURING INCREMENTAL- AND DECREMENTAL-RAMP CYCLE ERGOMETRY

    Directory of Open Access Journals (Sweden)

    Fadıl Özyener

    2011-09-01

    Full Text Available The pulmonary oxygen uptake (VO2 response to incremental-ramp cycle ergometry typically demonstrates lagged-linear first-order kinetics with a slope of ~10-11 ml·min-1·W-1, both above and below the lactate threshold (ӨL, i.e. there is no discernible VO2 slow component (or "excess" VO2 above ӨL. We were interested in determining whether a reverse ramp profile would yield the same response dynamics. Ten healthy males performed a maximum incremental -ramp (15-30 W·min-1, depending on fitness. On another day, the work rate (WR was increased abruptly to the incremental maximum and then decremented at the same rate of 15-30 W.min-1 (step-decremental ramp. Five subjects also performed a sub-maximal ramp-decremental test from 90% of ӨL. VO2 was determined breath-by-breath from continuous monitoring of respired volumes (turbine and gas concentrations (mass spectrometer. The incremental-ramp VO2-WR slope was 10.3 ± 0.7 ml·min-1·W-1, whereas that of the descending limb of the decremental ramp was 14.2 ± 1.1 ml·min-1·W-1 (p < 0.005. The sub-maximal decremental-ramp slope, however, was only 9. 8 ± 0.9 ml·min-1·W-1: not significantly different from that of the incremental-ramp. This suggests that the VO2 response in the supra-ӨL domain of incremental-ramp exercise manifest not actual, but pseudo, first-order kinetics

  16. Atmospheric response to Saharan dust deduced from ECMWF reanalysis (ERA) temperature increments

    Science.gov (United States)

    Kishcha, P.; Alpert, P.; Barkan, J.; Kirchner, I.; Machenhauer, B.

    2003-09-01

    This study focuses on the atmospheric temperature response to dust deduced from a new source of data the European Reanalysis (ERA) increments. These increments are the systematic errors of global climate models, generated in the reanalysis procedure. The model errors result not only from the lack of desert dust but also from a complex combination of many kinds of model errors. Over the Sahara desert the lack of dust radiative effect is believed to be a predominant model defect which should significantly affect the increments. This dust effect was examined by considering correlation between the increments and remotely sensed dust. Comparisons were made between April temporal variations of the ERA analysis increments and the variations of the Total Ozone Mapping Spectrometer aerosol index (AI) between 1979 and 1993. The distinctive structure was identified in the distribution of correlation composed of three nested areas with high positive correlation (>0.5), low correlation and high negative correlation (Forecast (ECMWF) suggest that the PCA (NCA) corresponds mainly to anticyclonic (cyclonic) flow, negative (positive) vorticity and downward (upward) airflow. These findings are associated with the interaction between dust-forced heating/cooling and atmospheric circulation. This paper contributes to a better understanding of dust radiative processes missed in the model.

  17. A compact high resolution electrospray ionization ion mobility spectrometer.

    Science.gov (United States)

    Reinecke, T; Kirk, A T; Ahrens, A; Raddatz, C-R; Thoben, C; Zimmermann, S

    2016-04-01

    Electrospray is a commonly used ionization method for the analysis of liquids. An electrospray is a dispersed nebular of charged droplets produced under the influence of a strong electrical field. Subsequently, ions are produced in a complex process initiated by evaporation of neutral solvent molecules from these droplets. We coupled an electrospray ionization source to our previously described high resolution ion mobility spectrometer with 75 mm drift tube length and a drift voltage of 5 kV. When using a tritium source for chemical gas phase ionization, a resolving power of R=100 was reported for this setup. We replaced the tritium source and the field switching shutter by an electrospray needle, a desolvation region with variable length and a three-grid shutter for injecting ions into the drift region. Preliminary measurements with tetraalkylammonium halides show that the current configuration with the electrospray ionization source maintains the resolving power of R=100. In this work, we present the characterization of our setup. One major advantage of our setup is that the desolvation region can be heated separately from the drift region so that the temperature in the drift region stays at room temperature even up to desolvation region temperatures of 100 °C. We perform parametric studies for the investigation of the influence of temperature on solvent evaporation with different ratios of water and methanol in the solvent for different analyte substances. Furthermore, the setup is operated in negative mode and spectra of bentazon with different solvents are presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Using the transportable, computer-operated, liquid-scintillator fast-neutron spectrometer system

    International Nuclear Information System (INIS)

    Thorngate, J.H.

    1988-01-01

    When a detailed energy spectrum is needed for radiation-protection measurements from approximately 1 MeV up to several tens of MeV, organic-liquid scintillators make good neutron spectrometers. However, such a spectrometer requires a sophisticated electronics system and a computer to reduce the spectrum from the recorded data. Recently, we added a Nuclear Instrument Module (NIM) multichannel analyzer and a lap-top computer to the NIM electronics we have used for several years. The result is a transportable fast-neutron spectrometer system. The computer was programmed to guide the user through setting up the system, calibrating the spectrometer, measuring the spectrum, and reducing the data. Measurements can be made over three energy ranges, 0.6--2 MeV, 1.1--8 MeV, or 1.6--16 MeV, with the spectrum presented in 0.1-MeV increments. Results can be stored on a disk, presented in a table, and shown in graphical form. 5 refs., 51 figs

  19. spectrometer

    Directory of Open Access Journals (Sweden)

    J. K. Hedelius

    2016-08-01

    Full Text Available Bruker™ EM27/SUN instruments are commercial mobile solar-viewing near-IR spectrometers. They show promise for expanding the global density of atmospheric column measurements of greenhouse gases and are being marketed for such applications. They have been shown to measure the same variations of atmospheric gases within a day as the high-resolution spectrometers of the Total Carbon Column Observing Network (TCCON. However, there is little known about the long-term precision and uncertainty budgets of EM27/SUN measurements. In this study, which includes a comparison of 186 measurement days spanning 11 months, we note that atmospheric variations of Xgas within a single day are well captured by these low-resolution instruments, but over several months, the measurements drift noticeably. We present comparisons between EM27/SUN instruments and the TCCON using GGG as the retrieval algorithm. In addition, we perform several tests to evaluate the robustness of the performance and determine the largest sources of errors from these spectrometers. We include comparisons of XCO2, XCH4, XCO, and XN2O. Specifically we note EM27/SUN biases for January 2015 of 0.03, 0.75, –0.12, and 2.43 % for XCO2, XCH4, XCO, and XN2O respectively, with 1σ running precisions of 0.08 and 0.06 % for XCO2 and XCH4 from measurements in Pasadena. We also identify significant error caused by nonlinear sensitivity when using an extended spectral range detector used to measure CO and N2O.

  20. UARS Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL V009 (UARCL3AL) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — The Cryogenic Limb Array Etalon Spectrometer (CLAES) Level 3AL data product consists of daily, 4 degree increment latitude-ordered vertical profiles of temperature...

  1. Intercomparison of air ion spectrometers: an evaluation of results in varying conditions

    Directory of Open Access Journals (Sweden)

    S. Gagné

    2011-05-01

    Full Text Available We evaluated 11 air ion spectrometers from Airel Ltd. after they had spent one year in field measurements as a part of the EUCAARI project: 5 Air Ion Spectrometers (AIS, 5 Neutral cluster and Air Ion Spectrometers (NAIS and one Airborne NAIS (ANAIS. This is the first time that an ANAIS is evaluated and compared so extensively. The ion spectrometers' mobility and concentration accuracy was evaluated. Their measurements of ambient air were compared between themselves and to reference instruments: a Differential Mobility Particle Sizer (DMPS, a Balanced Scanning Mobility Analyzer (BSMA, and an Ion-DMPS. We report on the simultaneous measurement of a new particle formation (NPF event by all 11 instruments and the 3 reference instruments. To our knowledge, it is the first time that the size distribution of ions and particles is measured by so many ion spectrometers during a NPF event. The new particle formation rates (~0.2 cm−3 s−1 for ions and ~2 cm−3 s−1 for particles and growth rates (~25 nm h−1 in the 3–7 nm size range were calculated for all the instruments. The NAISs and the ANAIS gave higher concentrations and formation rates than the AISs. For example, the AISs agreed with the BSMA within 11 % and 28 % for negative and positive ion concentration respectively, whereas the NAISs agreed within 23 % and 29 %. Finally, based on the results presented here, we give guidelines for data evaluation, when data from different individual ion spectrometers are compared.

  2. Investigation of Tree Spectral Reflectance Characteristics Using a Mobile Terrestrial Line Spectrometer and Laser Scanner

    Directory of Open Access Journals (Sweden)

    Eetu Puttonen

    2013-07-01

    Full Text Available In mobile terrestrial hyperspectral imaging, individual trees often present large variations in spectral reflectance that may impact the relevant applications, but the related studies have been seldom reported. To fill this gap, this study was dedicated to investigating the spectral reflectance characteristics of individual trees with a Sensei mobile mapping system, which comprises a Specim line spectrometer and an Ibeo Lux laser scanner. The addition of the latter unit facilitates recording the structural characteristics of the target trees synchronously, and this is beneficial for revealing the characteristics of the spatial distributions of tree spectral reflectance with variations at different levels. Then, the parts of trees with relatively low-level variations can be extracted. At the same time, since it is difficult to manipulate the whole spectrum, the traditional concept of vegetation indices (VI based on some particular spectral bands was taken into account here. Whether the assumed VIs capable of behaving consistently for the whole crown of each tree was also checked. The specific analyses were deployed based on four deciduous tree species and six kinds of VIs. The test showed that with the help of the laser scanner data, the parts of individual trees with relatively low-level variations can be located. Based on these parts, the relatively stable spectral reflectance characteristics for different tree species can be learnt.

  3. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  4. Just-in-Time Technology to Encourage Incremental, Dietary Behavior Change

    OpenAIRE

    Intille, Stephen S.; Kukla, Charles; Farzanfar, Ramesh; Bakr, Waseem

    2003-01-01

    Our multi-disciplinary team is developing mobile computing software that uses “just-in-time” presentation of information to motivate behavior change. Using a participatory design process, preliminary interviews have helped us to establish 10 design goals. We have employed some to create a prototype of a tool that encourages better dietary decision making through incremental, just-in-time motivation at the point of purchase.

  5. Just-in-Time Technology to Encourage Incremental, Dietary Behavior Change

    Science.gov (United States)

    Intille, Stephen S.; Kukla, Charles; Farzanfar, Ramesh; Bakr, Waseem

    2003-01-01

    Our multi-disciplinary team is developing mobile computing software that uses “just-in-time” presentation of information to motivate behavior change. Using a participatory design process, preliminary interviews have helped us to establish 10 design goals. We have employed some to create a prototype of a tool that encourages better dietary decision making through incremental, just-in-time motivation at the point of purchase. PMID:14728379

  6. Implementing Kernel Methods Incrementally by Incremental Nonlinear Projection Trick.

    Science.gov (United States)

    Kwak, Nojun

    2016-05-20

    Recently, the nonlinear projection trick (NPT) was introduced enabling direct computation of coordinates of samples in a reproducing kernel Hilbert space. With NPT, any machine learning algorithm can be extended to a kernel version without relying on the so called kernel trick. However, NPT is inherently difficult to be implemented incrementally because an ever increasing kernel matrix should be treated as additional training samples are introduced. In this paper, an incremental version of the NPT (INPT) is proposed based on the observation that the centerization step in NPT is unnecessary. Because the proposed INPT does not change the coordinates of the old data, the coordinates obtained by INPT can directly be used in any incremental methods to implement a kernel version of the incremental methods. The effectiveness of the INPT is shown by applying it to implement incremental versions of kernel methods such as, kernel singular value decomposition, kernel principal component analysis, and kernel discriminant analysis which are utilized for problems of kernel matrix reconstruction, letter classification, and face image retrieval, respectively.

  7. A compact high resolution ion mobility spectrometer for fast trace gas analysis.

    Science.gov (United States)

    Kirk, Ansgar T; Allers, Maria; Cochems, Philipp; Langejuergen, Jens; Zimmermann, Stefan

    2013-09-21

    Drift tube ion mobility spectrometers (IMS) are widely used for fast trace gas detection in air, but portable compact systems are typically very limited in their resolving power. Decreasing the initial ion packet width improves the resolution, but is generally associated with a reduced signal-to-noise-ratio (SNR) due to the lower number of ions injected into the drift region. In this paper, we present a refined theory of IMS operation which employs a combined approach for the analysis of the ion drift and the subsequent amplification to predict both the resolution and the SNR of the measured ion current peak. This theoretical analysis shows that the SNR is not a function of the initial ion packet width, meaning that compact drift tube IMS with both very high resolution and extremely low limits of detection can be designed. Based on these implications, an optimized combination of a compact drift tube with a length of just 10 cm and a transimpedance amplifier has been constructed with a resolution of 183 measured for the positive reactant ion peak (RIP(+)), which is sufficient to e.g. separate the RIP(+) from the protonated acetone monomer, even though their drift times only differ by a factor of 1.007. Furthermore, the limits of detection (LODs) for acetone are 180 pptv within 1 s of averaging time and 580 pptv within only 100 ms.

  8. Miniature GC-Minicell Ion Mobility Spectrometer (IMS) for In Situ Measurements in Astrobiology Planetary Missions

    Science.gov (United States)

    Kojiro, Daniel R.; Stimac, Robert M.; Kaye, William J.; Holland, Paul M.; Takeuchi, Norishige

    2006-01-01

    Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or ionger mission life for stationary landers/laboratories. The miniCometary Ice and Dust Experiment (miniCIDEX), which combined Gas Chromatography (GC) with helium Ion Mobility Spectrometry (IMS), was capable of providing the wide range of analytical information required for Astrobiology missions. The IMS used here was based on the PCP model 111 IMS. A similar system, the Titan Ice and Dust Experiment (TIDE), was proposed as part of the Titan Orbiter Aerorover Mission (TOAM). Newer GC systems employing Micro Electro- Mechanical System (MEMS) based technology have greatly reduced both the size and resource requirements for space GCs. These smaller GCs, as well as the continuing miniaturization of Astrobiology analytical instruments in general, has highlighted the need for smaller, dry helium IMS systems. We describe here the development of a miniature, MEMS GC-IMS system (MEMS GC developed by Thorleaf Research Inc.), employing the MiniCell Ion Mobility Spectrometer (IMS), from Ion Applications Inc., developed through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA s Small Business Innovative Research (SBIR) Program.

  9. Comparison of the performance of three ion mobility spectrometers for measurement of biogenic amines

    International Nuclear Information System (INIS)

    Karpas, Zeev; Guamán, Ana V.; Pardo, Antonio; Marco, Santiago

    2013-01-01

    Graphical abstract: The response to different amounts of TMA (in μg) that were placed in a headspace vial as a function of time for the VG-Test (top) and the GDA (bottom). Note that the ratio [TMA/(TMA + TEP)] (top) and [TMA/(TMA + RIP)] (bottom) and the clearance time increase with the amount of TMA deposited in the vial. Highlights: ► First comparison of performance of IMS devices. ► Gas-phase ion chemistry affected by operational parameters. ► Limits of detection quite similar despite differences in devices. ► LODs determined in controlled continuous flow and in headspace vapor. ► Exponential dilution of headspace studies. - Abstract: The performance of three different types of ion mobility spectrometer (IMS) devices: GDA2 with a radioactive ion source (Airsense, Germany), UV-IMS with a photo-ionization source (G.A.S. Germany) and VG-Test with a corona discharge source (3QBD, Israel) was studied. The gas-phase ion chemistry in the IMS devices affected the species formed and their measured reduced mobility values. The sensitivity and limit of detection for trimethylamine (TMA), putrescine and cadaverine were compared by continuous monitoring of a stream of air with a given concentration of the analyte and by measurement of headspace vapors of TMA in a sealed vial. Preprocessing of the mobility spectra and the effectiveness of multivariate curve resolution techniques (MCR-LASSO) improved the accuracy of the measurements by correcting baseline effects and adjusting for variations in drift time as well as enhancing the signal to noise ratio and deconvolution of the complex data matrix to their pure components. The limit of detection for measurement of the biogenic amines by the three IMS devices was between 0.1 and 1.2 ppm (for TMA with the VG-Test and GDA, respectively) and between 0.2 and 0.7 ppm for putrescine and cadaverine with all three devices. Considering the uncertainty in the LOD determination there is almost no statistically significant

  10. Installation of a variable-angle spectrometer system for monitoring diffuse and global solar radiation

    Science.gov (United States)

    Ormachea, O.; Abrahamse, A.; Tolavi, N.; Romero, F.; Urquidi, O.; Pearce, J. M.; Andrews, R.

    2013-11-01

    We report on the design and installation of a spectrometer system for monitoring solar radiation in Cochabamba, Bolivia. Both the light intensity and the spectral distribution affect the power produced by a photovoltaic device. Local variations in the solar spectrum (especially compared to the AM1.5 standard) may have important implications for device optimization and energy yield estimation. The spectrometer system, based on an Ocean Optics USB4000 (300-900nm) spectrometer, was designed to increase functionality. Typically systems only record the global horizontal radiation. Our system moves a fiber-optic cable 0-90 degrees and takes measurements in 9 degree increments. Additionally, a shadow band allows measurement of the diffuse component of the radiation at each position. The electronic controls utilize an Arduino UNO microcontroller to synchronizes the movement of two PAP bipolar (stepper) motors with the activation of the spectrometer via an external trigger. The spectrometer was factory calibrated for wavelength and calibrated for absolute irradiance using a Sellarnet SL1-Cal light source. We present preliminary results from data taken March-June, 2013, and comment on implications for PV devices in Cochabamba.

  11. A spectrometer for submicron particles

    International Nuclear Information System (INIS)

    Pourprix, M.

    1995-01-01

    The electrostatic spectrometer for aerosol particles, is composed of two coaxial parallel conductive disks between which an electric field is established; an annular slot in the first disk allows for the atmosphere air intake. Suction and injection systems, and a third intermediate conductive disk are used to carry out a dynamic confinement that allows for the separation of particles having various electronic mobility and the determination of the suspended particle size distribution. Application to aerosol size spectrum determination and air quality monitoring

  12. Cost-effectiveness of increasing access to mammography through mobile mammography for older women.

    Science.gov (United States)

    Naeim, Arash; Keeler, Emmett; Bassett, Lawrence W; Parikh, Jay; Bastani, Roshan; Reuben, David B

    2009-02-01

    To compare the costs of mobile and stationary mammography and examine the incremental cost-effectiveness of using mobile mammography to increase screening rates. A cost-effectiveness analysis was performed using effectiveness data from a randomized clinical trial and modeling of costs associated with the mobile mammography intervention. The trial involved 60 community-based meal sites, senior centers, and clubs. Four hundred ninety-nine individuals were enrolled in the study, of whom 463 had outcome data available for analysis. Costs were calculated for stationary and mobile mammography, as well as costs due to differences in technology and film versus digital. Incremental cost-effectiveness (cost per additional screen) was modeled, and sensitivity analysis was performed by altering efficiency (throughput) and effectiveness based on subgroup data from the randomized trial. The estimated annual costs were $435,162 for a stationary unit, $539,052 for a mobile film unit, and $456, 392 for a mobile digital unit. Assuming mobile units are less efficient (50% annual volume), the cost per screen was $41 for a stationary unit, $86 for a mobile film unit, and $102 for a mobile digital unit. The incremental cost per additional screen were $207 for a mobile film unit and $264 for a mobile digital unit over a stationary unit. Although mobile mammography is a more effective way to screen older women, the absolute cost per screen of mobile units is higher, whereas the reimbursement is no different. Financial barriers may impede the widespread use of this approach.

  13. Incremental and Enhanced Scanline-Based Segmentation Method for Surface Reconstruction of Sparse LiDAR Data

    Directory of Open Access Journals (Sweden)

    Weimin Wang

    2016-11-01

    Full Text Available The segmentation of point clouds is an important aspect of automated processing tasks such as semantic extraction. However, the sparsity and non-uniformity of the point clouds gathered by the popular 3D mobile LiDAR devices pose many challenges for existing segmentation methods. To improve the segmentation results of point clouds from mobile LiDAR devices, we propose an optimized segmentation method based on Scanline Continuity Constraint (SLCC in this work. Unlike conventional scanline-based segmentation methods, SLCC clusters scanlines using the continuity constraints in terms of the distance as well as the direction of two consecutive points. In addition, scanline clusters are agglomerated not only into primitive geometrical shapes but also irregular shapes. Another downside to existing segmentation methods is that they are not capable of incremental processing. This causes unnecessary memory and time consumption for applications that require frame-wise segmentation or when new point clouds are added. In order to address this, we propose an incremental scheme—the Incremental Recursive Segmentation (IRIS, that can be easily applied to any segmentation method. IRIS is achieved by combining the segments of newly added point clouds and the previously segmented results. Furthermore, as an example application, we construct a processing pipeline consisting of plane fitting and surface reconstruction using the segmentation results. Finally, we evaluate the proposed methods on three datasets acquired from a handheld Velodyne HDL-32E LiDAR device. The experimental results verify the efficiency of IRIS for any segmentation method and the advantages of SLCC for processing mobile LiDAR data.

  14. Building biomarker libraries with novel chemical sensors: correlating differential mobility spectrometer signal outputs with mass spectrometry data

    International Nuclear Information System (INIS)

    Schivo, Michael; Kenyon, Nicholas J; Aksenov, Alexander A; Bardaweel, Hamzeh; Zhao Weixiang; Davis, Cristina E

    2011-01-01

    Gas chromatography/mass spectrometry (GC/MS) is a widely used analytic tool for qualitative and quantitative analysis of volatile and semi-volatile compounds. However, GC/MS use is limited by its large size, lack of portability, high cost and inherent complexity. Smaller instruments capable of high-throughput analysis of volatile compounds have the potential of combining MS-like sensitivity with portability. The micromachined differential mobility spectrometer (DMS) is a miniature sensor capable of registering volatile compounds in sub-parts-per-million (ppm) concentrations. It is small, portable, and can be coupled with multiple other compound separation methods. Here we describe paired volatile sample analyses using both GC/MS and GC/DMS which show that the DMS is capable of registering known compounds as verified by MS. Furthermore, we show that MS can be used to help build a library for our unique DMS sensor outputs and detect compounds in chemically complex backgrounds.

  15. Building biomarker libraries with novel chemical sensors: correlating differential mobility spectrometer signal outputs with mass spectrometry data

    Energy Technology Data Exchange (ETDEWEB)

    Schivo, Michael; Kenyon, Nicholas J [Division of Pulmonary and Critical Care Medicine, Genome and Biomedical Sciences Facility, University of California, Davis, CA 95616 (United States); Aksenov, Alexander A; Bardaweel, Hamzeh; Zhao Weixiang; Davis, Cristina E, E-mail: cedavis@ucdavis.edu [Department of Mechanical and Aerospace Engineering, One Shields Avenue, University of California, Davis, CA 95616 (United States)

    2011-10-29

    Gas chromatography/mass spectrometry (GC/MS) is a widely used analytic tool for qualitative and quantitative analysis of volatile and semi-volatile compounds. However, GC/MS use is limited by its large size, lack of portability, high cost and inherent complexity. Smaller instruments capable of high-throughput analysis of volatile compounds have the potential of combining MS-like sensitivity with portability. The micromachined differential mobility spectrometer (DMS) is a miniature sensor capable of registering volatile compounds in sub-parts-per-million (ppm) concentrations. It is small, portable, and can be coupled with multiple other compound separation methods. Here we describe paired volatile sample analyses using both GC/MS and GC/DMS which show that the DMS is capable of registering known compounds as verified by MS. Furthermore, we show that MS can be used to help build a library for our unique DMS sensor outputs and detect compounds in chemically complex backgrounds.

  16. Interfacing of home-made photoacoustic spectrometer to computer

    International Nuclear Information System (INIS)

    Dhobale, A.R.; Chaturvedi, T.P.; Venkiteswaran, S.; Sastry, M.D.

    1996-01-01

    This report describes the interfacing of Photo Acoustic Spectrometer (PAS) fabricated in-house to a personal computer. This work was carried out to make a state of the art computer based spectrometer with provision for automatic background correction and also which gives hard copy of the spectrum. This report includes the development of software necessary to acquire data and for further processing of the signal. The monochromator used was modified for obtaining a +5 V pulse for each wavelength position. This pulse was further used for controlling the data acquisition and automatic increment of wavelength. Software program was developed in Quick Basic ver. 4.5 environment for acquisition, storage, display and analysis of the spectrum. The program displays on-line spectrum building up on the monitor. Another program converts the acquired spectrum into a normalized spectrum comparing with carbon spectrum stored already in addition to the S/N ratio improvement. The photo acoustic cell and chopper unit were also modified for improving the performance of the PAS unit. (author). 11 refs., 13 figs., 2 tabs

  17. High contributions of vehicular emissions to ammonia in three European cities derived from mobile measurements

    Science.gov (United States)

    Elser, Miriam; El-Haddad, Imad; Maasikmets, Marek; Bozzetti, Carlo; Wolf, Robert; Ciarelli, Giancarlo; Slowik, Jay G.; Richter, Rene; Teinemaa, Erik; Hüglin, Christoph; Baltensperger, Urs; Prévôt, André S. H.

    2018-02-01

    Ambient ammonia (NH3) measurements were performed with a mobile platform in three European cities: Zurich (Switzerland), Tartu (Estonia) and Tallinn (Estonia) deploying an NH3 analyzer based on cavity ring-down spectroscopy. A heated inlet line along with an auxiliary flow was used to minimize NH3 adsorption onto the inlet walls. In addition, a detailed characterization of the response and recovery times of the measurement system was used to deconvolve the true NH3 signal from the remaining adsorption-induced hysteresis. Parallel measurements with an aerosol mass spectrometer were used to correct the observed NH3 for the contribution of ammonium nitrate, which completely evaporated in the heated line at the chosen temperature, in contrast to ammonium sulfate. In this way a quantitative measurement of ambient gaseous NH3 was achieved with sufficient time resolution to enable measurement of NH3 point sources with a mobile sampling platform. The NH3 analyzer and the aerosol mass spectrometer were complemented by an aethalometer and various gas-phase analyzers to enable a complete characterization of the sources of air pollution, including the spatial distributions and the regional background concentrations and urban increments of all measured components. Although at all three locations similar increment levels of organic aerosols were attributed to biomass burning and traffic, traffic emissions clearly dominated the city enhancements of NH3, equivalent black carbon (eBC) and carbon dioxide (CO2). Urban increments of 3.4, 1.8 and 3.0 ppb of NH3 were measured in the traffic areas in Zurich, Tartu and Tallinn, respectively, representing an enhancement of 36.6, 38.3 and 93.8% over the average background concentrations. Measurements in areas strongly influenced by traffic emissions (including tunnel drives) were used to estimate emission factors (EF) for the traffic-related pollutants. The obtained median EFs range between 136.8-415.1 mg kg-1 fuel for NH3, 157.1-734.8 mg

  18. Data for Users of Handheld Ion Mobility Spectrometers

    International Nuclear Information System (INIS)

    Keith A. Daum; Sandra L. Fox

    2008-01-01

    Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC) to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: (1) The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. (2) The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs departments (9%). (3) IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. (4) Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. (5) Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation

  19. Abnormal Gait Behavior Detection for Elderly Based on Enhanced Wigner-Ville Analysis and Cloud Incremental SVM Learning

    Directory of Open Access Journals (Sweden)

    Jian Luo

    2016-01-01

    Full Text Available A cloud based health care system is proposed in this paper for the elderly by providing abnormal gait behavior detection, classification, online diagnosis, and remote aid service. Intelligent mobile terminals with triaxial acceleration sensor embedded are used to capture the movement and ambulation information of elderly. The collected signals are first enhanced by a Kalman filter. And the magnitude of signal vector features is then extracted and decomposed into a linear combination of enhanced Gabor atoms. The Wigner-Ville analysis method is introduced and the problem is studied by joint time-frequency analysis. In order to solve the large-scale abnormal behavior data lacking problem in training process, a cloud based incremental SVM (CI-SVM learning method is proposed. The original abnormal behavior data are first used to get the initial SVM classifier. And the larger abnormal behavior data of elderly collected by mobile devices are then gathered in cloud platform to conduct incremental training and get the new SVM classifier. By the CI-SVM learning method, the knowledge of SVM classifier could be accumulated due to the dynamic incremental learning. Experimental results demonstrate that the proposed method is feasible and can be applied to aged care, emergency aid, and related fields.

  20. Correlation ion mobility spectroscopy

    Science.gov (United States)

    Pfeifer, Kent B [Los Lunas, NM; Rohde, Steven B [Corrales, NM

    2008-08-26

    Correlation ion mobility spectrometry (CIMS) uses gating modulation and correlation signal processing to improve IMS instrument performance. Closely spaced ion peaks can be resolved by adding discriminating codes to the gate and matched filtering for the received ion current signal, thereby improving sensitivity and resolution of an ion mobility spectrometer. CIMS can be used to improve the signal-to-noise ratio even for transient chemical samples. CIMS is especially advantageous for small geometry IMS drift tubes that can otherwise have poor resolution due to their small size.

  1. Measurement of acetates in air using differential ion mobility spectrometer

    Science.gov (United States)

    Szczurek, Andrzej; Maciejewska, Monika; Zajiczek, Żaneta; Maziejuk, Mirosław

    2017-11-01

    Volatile organic compounds are one of the most important group of air pollutants. Potential health and environmental problems resulting from their emission prompted the requirement for monitoring these species. It motivates development of new measurement techniques which are fast, cost effective, reliable and field deployable. One of novel approaches is ion mobility spectrometry. It dwells on ion separation in electric field, based on differences in ion mobility. Many variants of this method are developed. In this wok, differential ion mobility spectrometry (DMS) was considered in respect of acetate measurements in air. It was demonstrated that DMS offers linear response to methyl, ethyl, propyl and butyl acetate in concentration range from 0.3 ppm to 7 ppm. Positive ions spectrum has to be utilised for this purpose. We showed that fragments of DMS spectrum which secure linearity are compound-specific. The obtained results are promising from the application point of view.

  2. Advances in miniature spectrometer and sensor development

    Science.gov (United States)

    Malinen, Jouko; Rissanen, Anna; Saari, Heikki; Karioja, Pentti; Karppinen, Mikko; Aalto, Timo; Tukkiniemi, Kari

    2014-05-01

    Miniaturization and cost reduction of spectrometer and sensor technologies has great potential to open up new applications areas and business opportunities for analytical technology in hand held, mobile and on-line applications. Advances in microfabrication have resulted in high-performance MEMS and MOEMS devices for spectrometer applications. Many other enabling technologies are useful for miniature analytical solutions, such as silicon photonics, nanoimprint lithography (NIL), system-on-chip, system-on-package techniques for integration of electronics and photonics, 3D printing, powerful embedded computing platforms, networked solutions as well as advances in chemometrics modeling. This paper will summarize recent work on spectrometer and sensor miniaturization at VTT Technical Research Centre of Finland. Fabry-Perot interferometer (FPI) tunable filter technology has been developed in two technical versions: Piezoactuated FPIs have been applied in miniature hyperspectral imaging needs in light weight UAV and nanosatellite applications, chemical imaging as well as medical applications. Microfabricated MOEMS FPIs have been developed as cost-effective sensor platforms for visible, NIR and IR applications. Further examples of sensor miniaturization will be discussed, including system-on-package sensor head for mid-IR gas analyzer, roll-to-roll printed Surface Enhanced Raman Scattering (SERS) technology as well as UV imprinted waveguide sensor for formaldehyde detection.

  3. Deep Incremental Boosting

    OpenAIRE

    Mosca, Alan; Magoulas, George D

    2017-01-01

    This paper introduces Deep Incremental Boosting, a new technique derived from AdaBoost, specifically adapted to work with Deep Learning methods, that reduces the required training time and improves generalisation. We draw inspiration from Transfer of Learning approaches to reduce the start-up time to training each incremental Ensemble member. We show a set of experiments that outlines some preliminary results on some common Deep Learning datasets and discuss the potential improvements Deep In...

  4. On excursion increments in heartbeat dynamics

    International Nuclear Information System (INIS)

    Guzmán-Vargas, L.; Reyes-Ramírez, I.; Hernández-Pérez, R.

    2013-01-01

    We study correlation properties of excursion increments of heartbeat time series from healthy subjects and heart failure patients. We construct the excursion time based on the original heartbeat time series, representing the time employed by the walker to return to the local mean value. Next, the detrended fluctuation analysis and the fractal dimension method are applied to the magnitude and sign of the increments in the time excursions between successive excursions for the mentioned groups. Our results show that for magnitude series of excursion increments both groups display long-range correlations with similar correlation exponents, indicating that large (small) increments (decrements) are more likely to be followed by large (small) increments (decrements). For sign sequences and for both groups, we find that increments are short-range anti-correlated, which is noticeable under heart failure conditions

  5. Rapid Measurements of Aerosol Size Distribution and Hygroscopic Growth via Image Processing with a Fast Integrated Mobility Spectrometer (FIMS)

    Science.gov (United States)

    Wang, Y.; Pinterich, T.; Spielman, S. R.; Hering, S. V.; Wang, J.

    2017-12-01

    Aerosol size distribution and hygroscopicity are among key parameters in determining the impact of atmospheric aerosols on global radiation and climate change. In situ submicron aerosol size distribution measurements commonly involve a scanning mobility particle sizer (SMPS). The SMPS scanning time is in the scale of minutes, which is often too slow to capture the variation of aerosol size distribution, such as for aerosols formed via nucleation processes or measurements onboard research aircraft. To solve this problem, a Fast Integrated Mobility Spectrometer (FIMS) based on image processing was developed for rapid measurements of aerosol size distributions from 10 to 500 nm. The FIMS consists of a parallel plate classifier, a condenser, and a CCD detector array. Inside the classifier an electric field separates charged aerosols based on electrical mobilities. Upon exiting the classifier, the aerosols pass through a three stage growth channel (Pinterich et al. 2017; Spielman et al. 2017), where aerosols as small as 7 nm are enlarged to above 1 μm through water or heptanol condensation. Finally, the grown aerosols are illuminated by a laser sheet and imaged onto a CCD array. The images provide both aerosol concentration and position, which directly relate to the aerosol size distribution. By this simultaneous measurement of aerosols with different sizes, the FIMS provides aerosol size spectra nearly 100 times faster than the SMPS. Recent deployment onboard research aircraft demonstrated that the FIMS is capable of measuring aerosol size distributions in 1s (Figure), thereby offering a great advantage in applications requiring high time resolution (Wang et al. 2016). In addition, the coupling of the FIMS with other conventional aerosol instruments provides orders of magnitude more rapid characterization of aerosol optical and microphysical properties. For example, the combination of a differential mobility analyzer, a relative humidity control unit, and a FIMS was

  6. A 64 Mbyte VME histogramming memory card for the GA.SP gamma spectrometer

    International Nuclear Information System (INIS)

    Cavedini, Z.; DePoli, M.; Maron, G.; Vedovato, G.

    1990-01-01

    This paper reports on a 64 Mbyte VME histogramming memory card designed and built to cover the on-line and off-line data analysis needs of the GA.SP spectrometer (a 40 HpGe gamma detector array in development at LNL). The card combines the standard features of the VME/VSB bus with some special built-in functions: single cycle fast histogramming operations (typical channel increment time of 550 ns including the bus arbitration), fast clear of the whole memory (∼1 second to erase 64 Mbyte) and data broadcasting

  7. Spherical grating spectrometers

    Science.gov (United States)

    O'Donoghue, Darragh; Clemens, J. Christopher

    2014-07-01

    We describe designs for spectrometers employing convex dispersers. The Offner spectrometer was the first such instrument; it has almost exclusively been employed on satellite platforms, and has had little impact on ground-based instruments. We have learned how to fabricate curved Volume Phase Holographic (VPH) gratings and, in contrast to the planar gratings of traditional spectrometers, describe how such devices can be used in optical/infrared spectrometers designed specifically for curved diffraction gratings. Volume Phase Holographic gratings are highly efficient compared to conventional surface relief gratings; they have become the disperser of choice in optical / NIR spectrometers. The advantage of spectrometers with curved VPH dispersers is the very small number of optical elements used (the simplest comprising a grating and a spherical mirror), as well as illumination of mirrors off axis, resulting in greater efficiency and reduction in size. We describe a "Half Offner" spectrometer, an even simpler version of the Offner spectrometer. We present an entirely novel design, the Spherical Transmission Grating Spectrometer (STGS), and discuss exemplary applications, including a design for a double-beam spectrometer without any requirement for a dichroic. This paradigm change in spectrometer design offers an alternative to all-refractive astronomical spectrometer designs, using expensive, fragile lens elements fabricated from CaF2 or even more exotic materials. The unobscured mirror layout avoids a major drawback of the previous generation of catadioptric spectrometer designs. We describe laboratory measurements of the efficiency and image quality of a curved VPH grating in a STGS design, demonstrating, simultaneously, efficiency comparable to planar VPH gratings along with good image quality. The stage is now set for construction of a prototype instrument with impressive performance.

  8. The Calibration Home Base for Imaging Spectrometers

    Directory of Open Access Journals (Sweden)

    Johannes Felix Simon Brachmann

    2016-08-01

    Full Text Available The Calibration Home Base (CHB is an optical laboratory designed for the calibration of imaging spectrometers for the VNIR/SWIR wavelength range. Radiometric, spectral and geometric calibration as well as the characterization of sensor signal dependency on polarization are realized in a precise and highly automated fashion. This allows to carry out a wide range of time consuming measurements in an ecient way. The implementation of ISO 9001 standards in all procedures ensures a traceable quality of results. Spectral measurements in the wavelength range 380–1000 nm are performed to a wavelength uncertainty of +- 0.1 nm, while an uncertainty of +-0.2 nm is reached in the wavelength range 1000 – 2500 nm. Geometric measurements are performed at increments of 1.7 µrad across track and 7.6 µrad along track. Radiometric measurements reach an absolute uncertainty of +-3% (k=1. Sensor artifacts, such as caused by stray light will be characterizable and correctable in the near future. For now, the CHB is suitable for the characterization of pushbroom sensors, spectrometers and cameras. However, it is planned to extend the CHBs capabilities in the near future such that snapshot hyperspectral imagers can be characterized as well. The calibration services of the CHB are open to third party customers from research institutes as well as industry.

  9. Legislative Bargaining and Incremental Budgeting

    OpenAIRE

    Dhammika Dharmapala

    2002-01-01

    The notion of 'incrementalism', formulated by Aaron Wildavsky in the 1960's, has been extremely influential in the public budgeting literature. In essence, it entails the claim that legislators engaged in budgetary policymaking accept past allocations, and decide only on the allocation of increments to revenue. Wildavsky explained incrementalism with reference to the cognitive limitations of lawmakers and their desire to reduce conflict. This paper uses a legislative bargaining framework to u...

  10. Correlation spectrometer

    Science.gov (United States)

    Sinclair, Michael B [Albuquerque, NM; Pfeifer, Kent B [Los Lunas, NM; Flemming, Jeb H [Albuquerque, NM; Jones, Gary D [Tijeras, NM; Tigges, Chris P [Albuquerque, NM

    2010-04-13

    A correlation spectrometer can detect a large number of gaseous compounds, or chemical species, with a species-specific mask wheel. In this mode, the spectrometer is optimized for the direct measurement of individual target compounds. Additionally, the spectrometer can measure the transmission spectrum from a given sample of gas. In this mode, infrared light is passed through a gas sample and the infrared transmission signature of the gasses present is recorded and measured using Hadamard encoding techniques. The spectrometer can detect the transmission or emission spectra in any system where multiple species are present in a generally known volume.

  11. Unmanned Maritime Systems Incremental Acquisition Approach

    Science.gov (United States)

    2016-12-01

    REPORT TYPE AND DATES COVERED MBA professional report 4. TITLE AND SUBTITLE UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH 5. FUNDING...Approved for public release. Distribution is unlimited. UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH Thomas Driscoll, Lieutenant...UNMANNED MARITIME SYSTEMS INCREMENTAL ACQUISITION APPROACH ABSTRACT The purpose of this MBA report is to explore and understand the issues

  12. Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Hye Min Park

    2016-06-01

    Full Text Available In this study, a personal gamma (γ spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG crystal that was coupled to a Si photomultiplier (SiPM to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery, and measured only 5.0 × 7.0 cm2.

  13. FEM Simulation of Incremental Shear

    International Nuclear Information System (INIS)

    Rosochowski, Andrzej; Olejnik, Lech

    2007-01-01

    A popular way of producing ultrafine grained metals on a laboratory scale is severe plastic deformation. This paper introduces a new severe plastic deformation process of incremental shear. A finite element method simulation is carried out for various tool geometries and process kinematics. It has been established that for the successful realisation of the process the inner radius of the channel as well as the feeding increment should be approximately 30% of the billet thickness. The angle at which the reciprocating die works the material can be 30 deg. . When compared to equal channel angular pressing, incremental shear shows basic similarities in the mode of material flow and a few technological advantages which make it an attractive alternative to the known severe plastic deformation processes. The most promising characteristic of incremental shear is the possibility of processing very long billets in a continuous way which makes the process more industrially relevant

  14. Determination of chemical concentration with a 2 dimensional CCD array in the Echelle grating spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, D.K. [Lawrence Livermore National Lab., CA (United States); Stevens, C.G.

    1994-11-15

    The Echelle grating spectrometer (EGS) uses a stepped Echelle grating, prisms and a folded light path to miniaturize an infrared spectrometer. Light enters the system through a slit and is spread out along Y by a prism. This light then strikes the grating and is diffracted out along X. This spreading results in a superposition of spectral orders since the grating has a high spectral range. These orders are then separated by again passing through a prism. The end result of a measurement is a 2 dimensional image which contains the folded spectrum of the region under investigation. The data lies in bands from top to bottom, for example, with wavenumber increments as small as 0.1 lying from left to right such that the right end of band N is the same as the left end of band N+1. This is the image which must be analyzed.

  15. Comparison of linear intrascan and interscan dynamic ranges of Orbitrap and ion-mobility time-of-flight mass spectrometers.

    Science.gov (United States)

    Kaufmann, Anton; Walker, Stephan

    2017-11-30

    The linear intrascan and interscan dynamic ranges of mass spectrometers are important in metabolome and residue analysis. A large linear dynamic range is mandatory if both low- and high-abundance ions have to be detected and quantitated in heavy matrix samples. These performance criteria, as provided by modern high-resolution mass spectrometry (HRMS), were systematically investigated. The comparison included two generations of Orbitraps, and an ion mobility quadrupole time-of-flight (QTOF) system In addition, different scan modes, as provided by the utilized instruments, were investigated. Calibration curves of different compounds covering a concentration range of five orders of magnitude were measured to evaluate the linear interscan dynamic range. The linear intrascan dynamic range and the resulting mass accuracy were evaluated by repeating these measurements in the presence of a very intense background. Modern HRMS instruments can show linear dynamic ranges of five orders of magnitude. Often, however, the linear dynamic range is limited by the detection capability (sensitivity and selectivity) and by the electrospray ionization. Orbitraps, as opposed to TOF instruments, show a reduced intrascan dynamic range. This is due to the limited C-trap and Orbitrap capacity. The tested TOF instrument shows poorer mass accuracies than the Orbitraps. In contrast, hyphenation with an ion-mobility device seems not to affect the linear dynamic range. The linear dynamic range of modern HRMS instrumentation has been significantly improved. This also refers to the virtual absence of systematic mass shifts at high ion abundances. The intrascan dynamic range of the current Orbitrap technology may still be a limitation when analyzing complex matrix extracts. On the other hand, the linear dynamic range is not only limited by the detector technology, but can also be shortened by peripheral devices, where the ionization and transfer of ions take place. Copyright © 2017 John Wiley

  16. Drift tube measurements of mobilities and longitudinal diffusion coefficients of ions in gases

    International Nuclear Information System (INIS)

    Chelf, R.D.

    1982-01-01

    The zero-field mobilities of Br - and NH 4+ in O 2 were determined as a function of gas temperature in a high pressure drift tube mass spectrometer. The mobilities and longitudinal diffusion coefficients of the ion-gas combinations Br - in Ne and Kr, Li + in Xe, and Tl/ + in Kr and Xe were determined as a function of E/N, where E is the electric field strength and N is the gas number density in a low pressure drift tube mass spectrometer. The measured longitudinal diffusion coefficients were used for a test and comparison of the generalized Einstein relations of Viehland-Mason and Waldman-Mason theories. The measured mobilities of Br - in Kr and Tl/ + in Kr were used in an iterative-inversion scheme from which the ion-neutral interaction potentials were determined

  17. Real Time Mapping and Dynamic Navigation for Mobile Robots

    Directory of Open Access Journals (Sweden)

    Maki K. Habib

    2008-11-01

    Full Text Available This paper discusses the importance, the complexity and the challenges of mapping mobile robot?s unknown and dynamic environment, besides the role of sensors and the problems inherited in map building. These issues remain largely an open research problems in developing dynamic navigation systems for mobile robots. The paper presenst the state of the art in map building and localization for mobile robots navigating within unknown environment, and then introduces a solution for the complex problem of autonomous map building and maintenance method with focus on developing an incremental grid based mapping technique that is suitable for real-time obstacle detection and avoidance. In this case, the navigation of mobile robots can be treated as a problem of tracking geometric features that occur naturally in the environment of the robot. The robot maps its environment incrementally using the concept of occupancy grids and the fusion of multiple ultrasonic sensory information while wandering in it and stay away from all obstacles. To ensure real-time operation with limited resources, as well as to promote extensibility, the mapping and obstacle avoidance modules are deployed in parallel and distributed framework. Simulation based experiments has been conducted and illustrated to show the validity of the developed mapping and obstacle avoidance approach.

  18. Monolithic spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Rajic, Slobodan (Knoxville, TN); Egert, Charles M. (Oak Ridge, TN); Kahl, William K. (Knoxville, TN); Snyder, Jr., William B. (Knoxville, TN); Evans, III, Boyd M. (Oak Ridge, TN); Marlar, Troy A. (Knoxville, TN); Cunningham, Joseph P. (Oak Ridge, TN)

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  19. Development and Evaluation of a Reverse-Entry Ion Source Orbitrap Mass Spectrometer

    Science.gov (United States)

    Poltash, Michael L.; McCabe, Jacob W.; Patrick, John W.; Laganowsky, Arthur; Russell, David H.

    2018-05-01

    As a step towards development of a high-resolution ion mobility mass spectrometer using the orbitrap mass analyzer platform, we describe herein a novel reverse-entry ion source (REIS) coupled to the higher-energy C-trap dissociation (HCD) cell of an orbitrap mass spectrometer with extended mass range. Development of the REIS is a first step in the development of a drift tube ion mobility-orbitrap MS. The REIS approach retains the functionality of the commercial instrument ion source which permits the uninterrupted use of the instrument during development as well as performance comparisons between the two ion sources. Ubiquitin (8.5 kDa) and lipid binding to the ammonia transport channel (AmtB, 126 kDa) protein complex were used as model soluble and membrane proteins, respectively, to evaluate the performance of the REIS instrument. Mass resolution obtained with the REIS is comparable to that obtained using the commercial ion source. The charge state distributions for ubiquitin and AmtB obtained on the REIS are in agreement with previous studies which suggests that the REIS-orbitrap EMR retains native structure in the gas phase.

  20. Research of high power and stable laser in portable Raman spectrometer based on SHINERS technology

    Science.gov (United States)

    Cui, Yongsheng; Yin, Yu; Wu, Yulin; Ni, Xuxiang; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The intensity of Raman light is very weak, which is only from 10-12 to 10-6 of the incident light. In order to obtain the required sensitivity, the traditional Raman spectrometer tends to be heavy weight and large volume, so it is often used as indoor test device. Based on the Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) method, Raman optical spectrum signal can be enhanced significantly and the portable Raman spectrometer combined with SHINERS method will be widely used in various fields. The laser source must be stable enough and able to output monochromatic narrow band laser with stable power in the portable Raman spectrometer based on the SHINERS method. When the laser is working, the change of temperature can induce wavelength drift, thus the power stability of excitation light will be affected, so we need to strictly control the working temperature of the laser, In order to ensure the stability of laser power and output current, this paper adopts the WLD3343 laser constant current driver chip of Wavelength Electronics company and MCU P89LPC935 to drive LML - 785.0 BF - XX laser diode(LD). Using this scheme, the Raman spectrometer can be small in size and the drive current can be constant. At the same time, we can achieve functions such as slow start, over-current protection, over-voltage protection, etc. Continuous adjustable output can be realized under control, and the requirement of high power output can be satisfied. Max1968 chip is adopted to realize the accurate control of the laser's temperature. In this way, it can meet the demand of miniaturization. In term of temperature control, integral truncation effect of traditional PID algorithm is big, which is easy to cause static difference. Each output of incremental PID algorithm has nothing to do with the current position, and we can control the output coefficients to avoid full dose output and immoderate adjustment, then the speed of balance will be improved observably. Variable

  1. On conditional scalar increment and joint velocity-scalar increment statistics

    International Nuclear Information System (INIS)

    Zhang Hengbin; Wang Danhong; Tong Chenning

    2004-01-01

    Conditional velocity and scalar increment statistics are usually studied in the context of Kolmogorov's refined similarity hypotheses and are considered universal (quasi-Gaussian) for inertial-range separations. In such analyses the locally averaged energy and scalar dissipation rates are used as conditioning variables. Recent studies have shown that certain local turbulence structures can be captured when the local scalar variance (φ 2 ) r and the local kinetic energy k r are used as the conditioning variables. We study the conditional increments using these conditioning variables, which also provide the local turbulence scales. Experimental data obtained in the fully developed region of an axisymmetric turbulent jet are used to compute the statistics. The conditional scalar increment probability density function (PDF) conditional on (φ 2 ) r is found to be close to Gaussian for (φ 2 ) r small compared with its mean and is sub-Gaussian and bimodal for large (φ 2 ) r , and therefore is not universal. We find that the different shapes of the conditional PDFs are related to the instantaneous degree of non-equilibrium (production larger than dissipation) of the local scalar. There is further evidence of this from the conditional PDF conditional on both (φ 2 ) r and χ r , which is largely a function of (φ 2 ) r /χ r , a measure of the degree of non-equilibrium. The velocity-scalar increment joint PDF is close to joint Gaussian and quad-modal for equilibrium and non-equilibrium local velocity and scalar, respectively. The latter shape is associated with a combination of the ramp-cliff and plane strain structures. Kolmogorov's refined similarity hypotheses also predict a dependence of the conditional PDF on the degree of non-equilibrium. Therefore, the quasi-Gaussian (joint) PDF, previously observed in the context of Kolmogorov's refined similarity hypotheses, is only one of the conditional PDF shapes of inertial range turbulence. The present study suggests that

  2. Whirlpool routing for mobility

    KAUST Repository

    Lee, Jung Woo; Kusy, Branislav; Azim, Tahir; Shihada, Basem; Levis, Philip

    2010-01-01

    Using simulation, controlled testbeds, and real mobility experiments, we find that using the data plane for topology maintenance is highly effective due to the incremental nature of mobility updates. WARP leverages the fact that converging flows at a destination make the destination have the region of highest traffic. We provide a theoretical basis for WARP's behavior, defining an "update area" in which the topology must adjust when a destination moves. As long as packets arrive at a destination before it moves outside of the update area, WARP can repair the topology using the data plane. Compared to existing protocols, such as DYMO and HYPER, WARP's packet drop rate is up to 90% lower while sending up to 90% fewer packets.

  3. Multidimensional spectrometer

    Science.gov (United States)

    Zanni, Martin Thomas; Damrauer, Niels H.

    2010-07-20

    A multidimensional spectrometer for the infrared, visible, and ultraviolet regions of the electromagnetic spectrum, and a method for making multidimensional spectroscopic measurements in the infrared, visible, and ultraviolet regions of the electromagnetic spectrum. The multidimensional spectrometer facilitates measurements of inter- and intra-molecular interactions.

  4. Small angle spectrometers: Summary

    International Nuclear Information System (INIS)

    Courant, E.; Foley, K.J.; Schlein, P.E.

    1986-01-01

    Aspects of experiments at small angles at the Superconducting Super Collider are considered. Topics summarized include a small angle spectrometer, a high contingency spectrometer, dipole and toroid spectrometers, and magnet choices

  5. Spectrometer control subsystem with high level functionality for use at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Alberi, J.L.; Stubblefield, F.W.

    1980-11-01

    We have developed a subsystem capable of controlling stepping motors in a wide variety of vuv and x-ray spectrometers to be used at the National Sychrotron Light Source. The subsystem is capable of controlling up to 15 motors with encoder readback and ramped acceleration/deceleration. Both absolute and incremental encoders may be used in any mixture. Function commands to the subsystem are communicated via ASCII characters over an asynchronous serial link in a well-defined protocol in decipherable English. Thus the unit can be controlled via write statements in a high-level language. Details of hardware implementation will be presented

  6. Joint Transmit Antenna Selection and Power Allocation for ISDF Relaying Mobile-to-Mobile Sensor Networks.

    Science.gov (United States)

    Xu, Lingwei; Zhang, Hao; Gulliver, T Aaron

    2016-02-19

    The outage probability (OP) performance of multiple-relay incremental-selective decode-and-forward (ISDF) relaying mobile-to-mobile (M2M) sensor networks with transmit antenna selection (TAS) over N-Nakagami fading channels is investigated. Exact closed-form OP expressions for both optimal and suboptimal TAS schemes are derived. The power allocation problem is formulated to determine the optimal division of transmit power between the broadcast and relay phases. The OP performance under different conditions is evaluated via numerical simulation to verify the analysis. These results show that the optimal TAS scheme has better OP performance than the suboptimal scheme. Further, the power allocation parameter has a significant influence on the OP performance.

  7. The SPEDE spectrometer

    Science.gov (United States)

    Papadakis, P.; Cox, D. M.; O'Neill, G. G.; Borge, M. J. G.; Butler, P. A.; Gaffney, L. P.; Greenlees, P. T.; Herzberg, R.-D.; Illana, A.; Joss, D. T.; Konki, J.; Kröll, T.; Ojala, J.; Page, R. D.; Rahkila, P.; Ranttila, K.; Thornhill, J.; Tuunanen, J.; Van Duppen, P.; Warr, N.; Pakarinen, J.

    2018-03-01

    The electron spectrometer, SPEDE, has been developed and will be employed in conjunction with the Miniball spectrometer at the HIE-ISOLDE facility, CERN. SPEDE allows for direct measurement of internal conversion electrons emitted in-flight, without employing magnetic fields to transport or momentum filter the electrons. Together with the Miniball spectrometer, it enables simultaneous observation of γ rays and conversion electrons in Coulomb excitation experiments using radioactive ion beams.

  8. 48 CFR 3432.771 - Provision for incremental funding.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Provision for incremental funding. 3432.771 Section 3432.771 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION..., Incremental Funding, in a solicitation if a cost-reimbursement contract using incremental funding is...

  9. Ion mobility spectrometry after supercritical fluid chromatography

    International Nuclear Information System (INIS)

    Morrissey, M.A.

    1988-01-01

    In this work, a Fourier transform ion mobility spectrometer (FT-IMS) was constructed and evaluated as a detector for supercritical fluid chromatography (SFC). The FT-IMS provides both quantitative and qualitative data of a wide range of compounds, selective and nonselective modes of chromatographic detection, and it is compatible with a wide range of SFC mobile phases. Drift spectra are presented for a number of samples, including polymers, lipids, herbicides, antibiotics, and pharmaceuticals. The unique properties of supercritical fluids made it possible to introduce these compounds into the spectrometer. While the drift spectra presented are generally simple, showing only a quasi-molecular ion, a few are surprising complex. Examples of selective and non-selective detection demonstrate the usefulness of the detector. Examples are presented for fish oil concentrate, bacon grease extract, soil extract, and polymer mixtures. In the case of Triton X-100, a non-ionic surfactant, the FT-IMS was able to selectively detect individual oligomers in the polymer mixture. In the case of a polydimethylsilicone mixture the detector isolated a contaminant in the mixture

  10. Nationwide impact and vehicle to grid application of electric vehicles mobility using an activity based model

    OpenAIRE

    Álvaro, Roberto; González, Jairo; Fraile Ardanuy, José Jesús; Knapen, Luk; Janssens, Davy

    2013-01-01

    This paper describes the impact of electric mobility on the transmission grid in Flanders region (Belgium), using a micro-simulation activity based models. These models are used to provide temporal and spatial estimation of energy and power demanded by electric vehicles (EVs) in different mobility zones. The increment in the load demand due to electric mobility is added to the background load demand in these mobility areas and the effects over the transmission substations are analyzed. From t...

  11. Increment memory module for spectrometric data recording

    International Nuclear Information System (INIS)

    Zhuchkov, A.A.; Myagkikh, A.I.

    1988-01-01

    Incremental memory unit designed to input differential energy spectra of nuclear radiation is described. ROM application as incremental device has allowed to reduce the number of elements and do simplify information readout from the unit. 12-bit 2048 channels present memory unit organization. The device is connected directly with the bus of microprocessor systems similar to KR 580. Incrementation maximal time constitutes 3 mks. It is possible to use this unit in multichannel counting mode

  12. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  13. Design of a temperature control system using incremental PID algorithm for a special homemade shortwave infrared spatial remote sensor based on FPGA

    Science.gov (United States)

    Xu, Zhipeng; Wei, Jun; Li, Jianwei; Zhou, Qianting

    2010-11-01

    An image spectrometer of a spatial remote sensing satellite requires shortwave band range from 2.1μm to 3μm which is one of the most important bands in remote sensing. We designed an infrared sub-system of the image spectrometer using a homemade 640x1 InGaAs shortwave infrared sensor working on FPA system which requires high uniformity and low level of dark current. The working temperature should be -15+/-0.2 Degree Celsius. This paper studies the model of noise for focal plane array (FPA) system, investigated the relationship with temperature and dark current noise, and adopts Incremental PID algorithm to generate PWM wave in order to control the temperature of the sensor. There are four modules compose of the FPGA module design. All of the modules are coded by VHDL and implemented in FPGA device APA300. Experiment shows the intelligent temperature control system succeeds in controlling the temperature of the sensor.

  14. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects

    International Nuclear Information System (INIS)

    Besshejko, O.A.; Vishnevskij, I.N.; Denisenko, R.V.; Malyuk, I.A.; Petrosyan, Eh.E.; Karpenko, S.A.; Prijmak, V.N.

    2011-01-01

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO 4 that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4π-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  15. Planning Through Incrementalism

    Science.gov (United States)

    Lasserre, Ph.

    1974-01-01

    An incremental model of decisionmaking is discussed and compared with the Comprehensive Rational Approach. A model of reconciliation between the two approaches is proposed, and examples are given in the field of economic development and educational planning. (Author/DN)

  16. FDTD Stability: Critical Time Increment

    OpenAIRE

    Z. Skvor; L. Pauk

    2003-01-01

    A new approach suitable for determination of the maximal stable time increment for the Finite-Difference Time-Domain (FDTD) algorithm in common curvilinear coordinates, for general mesh shapes and certain types of boundaries is presented. The maximal time increment corresponds to a characteristic value of a Helmholz equation that is solved by a finite-difference (FD) method. If this method uses exactly the same discretization as the given FDTD method (same mesh, boundary conditions, order of ...

  17. Incremental Visualizer for Visible Objects

    DEFF Research Database (Denmark)

    Bukauskas, Linas; Bøhlen, Michael Hanspeter

    This paper discusses the integration of database back-end and visualizer front-end into a one tightly coupled system. The main aim which we achieve is to reduce the data pipeline from database to visualization by using incremental data extraction of visible objects in a fly-through scenarios. We...... also argue that passing only relevant data from the database will substantially reduce the overall load of the visualization system. We propose the system Incremental Visualizer for Visible Objects (IVVO) which considers visible objects and enables incremental visualization along the observer movement...... path. IVVO is the novel solution which allows data to be visualized and loaded on the fly from the database and which regards visibilities of objects. We run a set of experiments to convince that IVVO is feasible in terms of I/O operations and CPU load. We consider the example of data which uses...

  18. An approach to efficient mobility management in intelligent networks

    Science.gov (United States)

    Murthy, K. M. S.

    1995-01-01

    Providing personal communication systems supporting full mobility require intelligent networks for tracking mobile users and facilitating outgoing and incoming calls over different physical and network environments. In realizing the intelligent network functionalities, databases play a major role. Currently proposed network architectures envision using the SS7-based signaling network for linking these DB's and also for interconnecting DB's with switches. If the network has to support ubiquitous, seamless mobile services, then it has to support additionally mobile application parts, viz., mobile origination calls, mobile destination calls, mobile location updates and inter-switch handovers. These functions will generate significant amount of data and require them to be transferred between databases (HLR, VLR) and switches (MSC's) very efficiently. In the future, the users (fixed or mobile) may use and communicate with sophisticated CPE's (e.g. multimedia, multipoint and multisession calls) which may require complex signaling functions. This will generate volumness service handling data and require efficient transfer of these message between databases and switches. Consequently, the network providers would be able to add new services and capabilities to their networks incrementally, quickly and cost-effectively.

  19. Integrated Chemical and Microorganism Monitoring of Air Using Gas Chromatography/Ion Mobility Spectometry: Toward an Expanded-Use Volatile Organic Analyzer (VOA)

    Science.gov (United States)

    Eiceman, G. A.

    1999-01-01

    The work described in this research program originated with the choice by NASA of an ion mobility spectrometer for air quality monitoring on-board the international spacestation. Though the gas chromatograph-ion mobility spectrometer analyzer known as VOA met or exceeded expectations, limitations in the basic understanding of response and the utilization of foundational principles into usable technology was considered unacceptable. In this research program, a comprehensive model for the origins of mobility spectra was proposed, tested and verified. The principles considered responsible for the appearance of mobility spectra have now been elucidated through this project. This understanding has been applied in automated identification of mobility spectra using neural networks and routine procedures for this now exist. Finally, the limitation on linear range has been shown to be a technical limitation and not a fundamental limitation so that a hardware component was crafted to extend the linear range of a mobility spectrometer by 10X. This project has led to one Ph.D. dissertation and one MS thesis. In addition, over ten public presentations at professional meetings and six journal publications have resulted from this program of research. The findings are so plentiful that total analysis of the findings may require four to six years or more. The findings confirm that the decision to use VOA was sound and that the chemical and physical principles of mobility spectrometry are both understandable and predictable.

  20. The SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Pakarinen, J.; Papadakis, P. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J. [STFC Daresbury Laboratory, Warrington (United Kingdom)

    2014-03-15

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  1. The SAGE spectrometer

    International Nuclear Information System (INIS)

    Pakarinen, J.; Papadakis, P.; Sorri, J.; Greenlees, P.T.; Jones, P.; Julin, R.; Konki, J.; Rahkila, P.; Sandzelius, M.; Herzberg, R.D.; Butler, P.A.; Cox, D.M.; Cresswell, J.R.; Mistry, A.; Page, R.D.; Parr, E.; Sampson, J.; Seddon, D.A.; Thornhill, J.; Wells, D.; Coleman-Smith, P.J.; Lazarus, I.H.; Letts, S.C.; Pucknell, V.F.E.; Simpson, J.

    2014-01-01

    The SAGE spectrometer has been constructed for in-beam nuclear structure studies. SAGE combines a Ge-detector array and an electron spectrometer for detection of γ-rays and internal conversion electrons, respectively, and allows simultaneous observation of both electrons and γ-rays emitted from excited nuclei. SAGE is set up in the Accelerator Laboratory of the University of Jyvaeskylae and works in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer allowing the use of the recoil-decay tagging method. (orig.)

  2. Mobile Column Measurements of HCHO, NO2, NH3, and C2H6 in Colorado during FRAPPE

    Science.gov (United States)

    Kille, N.; Volkamer, R. M.; Baidar, S.; Ortega, I.; Sinreich, R.; Hannigan, J. W.; Cooper, O. R.; Nussbaumer, E.; Pfister, G.

    2015-12-01

    Gases from anthropogenic sources have the potential to have a profound impact on air quality. Emissions from large cattle feedlots and ONG (Oil and Natural Gas) sites are comprised of NH3 (ammonia) and C2H6 (ethane) as pollutants. C2H6 contributes to photochemical ozone (O3) production and oxidation production of HCHO (formaldehyde). NH3 is a major source for reactive nitrogen to form particulate matter 2.5, which negatively affects human health. NO2 (nitrogen dioxide), emitted during combustion, is considered a large-scale pollutant and contributes to the formation of O3. Deploying an innovative suite of remote sensing instruments in a mobile laboratory, a Multi Axis Differential Optical Absorption Spectrometer (MAX-DOAS), a UV-Vis Spectrometer, and a Fourier Transform Infrared Spectrometer, we obtain mobile column measurements at high spatial and temporal resolution, 2 seconds for the UV-Vis and IR spectrometers and 20 seconds for the MAX-DOAS. Within the scope of the Front Range Air Pollution and Photochemistry Experiment (FRAPPE) we measure total columns of HCHO, NO2, NH3, and C2H6 using the University of Colorado mobile laboratory. Emissions of urban areas, agriculture, and ONG sites were studied. For the measurement of total columns the solar occultation flux method has been applied. We measured significant variability in the columns. The measurement of total columns allows one to determine the emission flux and source strength when driving a closed box around or upwind and downwind of a source with the mobile laboratory. We present results from select research drives.

  3. Power variation for Gaussian processes with stationary increments

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Corcuera, J.M.; Podolskij, Mark

    2009-01-01

    We develop the asymptotic theory for the realised power variation of the processes X=•G, where G is a Gaussian process with stationary increments. More specifically, under some mild assumptions on the variance function of the increments of G and certain regularity conditions on the path of the pr......We develop the asymptotic theory for the realised power variation of the processes X=•G, where G is a Gaussian process with stationary increments. More specifically, under some mild assumptions on the variance function of the increments of G and certain regularity conditions on the path...... a chaos representation....

  4. A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources

    Science.gov (United States)

    Kirk, Ansgar Thomas; Kobelt, Tim; Spehlbrink, Hauke; Zimmermann, Stefan

    2018-05-01

    Corona discharge ionization sources are often used in ion mobility spectrometers (IMS) when a non-radioactive ion source with high ion currents is required. Typically, the corona discharge is followed by a reaction region where analyte ions are formed from the reactant ions. In this work, we present a simple yet sufficiently accurate model for predicting the ion current available at the end of this reaction region when operating at reduced pressure as in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) or most IMS-MS instruments. It yields excellent qualitative agreement with measurement results and is even able to calculate the ion current within an error of 15%. Additional interesting findings of this model are the ion current at the end of the reaction region being independent from the ion current generated by the corona discharge and the ion current in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) growing quadratically when scaling down the length of the reaction region. [Figure not available: see fulltext.

  5. 基于AdaBoost与BP神经网络增量学习的手机用户分类预测%Mobile Phone Users Classification Forecast Based on AdaBoost and BP Neural Network Incremental Learning

    Institute of Scientific and Technical Information of China (English)

    张冉

    2011-01-01

    随着3G网络的全面普及,手机广告目前已逐渐成为商家抢占市场的一种营销手段,但手机广告投放的精准性是目前比较突出的一个问题。本文介绍了BP神经网络以及AdaBoost算法的基本原理,研究了应用AdaBoost结合BP神经网络算法的增量学习模型,该模型基于用户历史点击记录来预测手机用户感兴趣的广告类别,以提高手机广告投放的精准度。%With the overall popularity of 3G networks,mobile advertising business has become a marketing tool to seize the market,but the precise nature of mobile advertising is a more prominent issue.This article describes the BP neural network and the basic principles of AdaBoost algorithm to study the application of BP neural network algorithm AdaBoost with incremental learning model that records based on user click history to predict the mobile phone users are interested in advertising categories,in order to improve the mobile advertising the accuracy.

  6. Energy-signal quality trade-offs in a WiMAX mobile station with a booster amplifier

    Science.gov (United States)

    Suherman; Mubarakah, N.; Wiranata, O.; Kasim, S. T.

    2018-02-01

    Worldwide Interoperability for Microwave Access (WiMAX) is a broadband wireless access technology that is able to provide high bit rate mobile internet services. Battery endurance remains a problem in current mobile communication. On the other hand, signal quality determines the successful run of the mobile applications. Energy consumption optimization cannot sacrifice the signal level required by the application to run smoothly. On the contrary, the application should consider battery life time. This paper examines the tradeoffs between energy and signal quality in WiMAX subscriber station by adjusting signal level using a booster amplifier. Simulation evaluations show that an increment of 0.00000104% energy consumption on using amplifier adaptively produces 16.411% signal to noise ratio (SNR) increment and 10.7% bit error rate (BER) decrement. By keeping the amplifier turned on, energy consumption increases up to 0.00000136%, causing the SNR rises to 17.2638% and BER drops to 11.13%. The evaluated application is video streaming, other application may behave differently.

  7. Incremental passivity and output regulation for switched nonlinear systems

    Science.gov (United States)

    Pang, Hongbo; Zhao, Jun

    2017-10-01

    This paper studies incremental passivity and global output regulation for switched nonlinear systems, whose subsystems are not required to be incrementally passive. A concept of incremental passivity for switched systems is put forward. First, a switched system is rendered incrementally passive by the design of a state-dependent switching law. Second, the feedback incremental passification is achieved by the design of a state-dependent switching law and a set of state feedback controllers. Finally, we show that once the incremental passivity for switched nonlinear systems is assured, the output regulation problem is solved by the design of global nonlinear regulator controllers comprising two components: the steady-state control and the linear output feedback stabilising controllers, even though the problem for none of subsystems is solvable. Two examples are presented to illustrate the effectiveness of the proposed approach.

  8. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects

    Directory of Open Access Journals (Sweden)

    O. A. Bezshyyko

    2011-12-01

    Full Text Available The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO4 that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  9. The Omicron Spectrometer

    CERN Document Server

    Allardyce, B W

    1976-01-01

    It is intended to build a spectrometer with a large solid angle and a large momentum acceptance at the reconstructed synchrocyclotron at CERN. This spectrometer will have an energy resolution of about 1 MeV for particles with momenta up to about 400 MeV/c.

  10. Theory of Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Martins, P.A.F.; Bay, Niels; Skjødt, Martin

    2008-01-01

    This paper presents a closed-form theoretical analysis modelling the fundamentals of single point incremental forming and explaining the experimental and numerical results available in the literature for the past couple of years. The model is based on membrane analysis with bi-directional in-plan......-plane contact friction and is focused on the extreme modes of deformation that are likely to be found in single point incremental forming processes. The overall investigation is supported by experimental work performed by the authors and data retrieved from the literature.......This paper presents a closed-form theoretical analysis modelling the fundamentals of single point incremental forming and explaining the experimental and numerical results available in the literature for the past couple of years. The model is based on membrane analysis with bi-directional in...

  11. Efficiency of Oral Incremental Rehearsal versus Written Incremental Rehearsal on Students' Rate, Retention, and Generalization of Spelling Words

    Science.gov (United States)

    Garcia, Dru; Joseph, Laurice M.; Alber-Morgan, Sheila; Konrad, Moira

    2014-01-01

    The purpose of this study was to examine the efficiency of an incremental rehearsal oral versus an incremental rehearsal written procedure on a sample of primary grade children's weekly spelling performance. Participants included five second and one first grader who were in need of help with their spelling according to their teachers. An…

  12. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  13. Performance Evaluation of Incremental K-means Clustering Algorithm

    OpenAIRE

    Chakraborty, Sanjay; Nagwani, N. K.

    2014-01-01

    The incremental K-means clustering algorithm has already been proposed and analysed in paper [Chakraborty and Nagwani, 2011]. It is a very innovative approach which is applicable in periodically incremental environment and dealing with a bulk of updates. In this paper the performance evaluation is done for this incremental K-means clustering algorithm using air pollution database. This paper also describes the comparison on the performance evaluations between existing K-means clustering and i...

  14. Demonstration of an ethane spectrometer for methane source identification.

    Science.gov (United States)

    Yacovitch, Tara I; Herndon, Scott C; Roscioli, Joseph R; Floerchinger, Cody; McGovern, Ryan M; Agnese, Michael; Pétron, Gabrielle; Kofler, Jonathan; Sweeney, Colm; Karion, Anna; Conley, Stephen A; Kort, Eric A; Nähle, Lars; Fischer, Marc; Hildebrandt, Lars; Koeth, Johannes; McManus, J Barry; Nelson, David D; Zahniser, Mark S; Kolb, Charles E

    2014-07-15

    Methane is an important greenhouse gas and tropospheric ozone precursor. Simultaneous observation of ethane with methane can help identify specific methane source types. Aerodyne Ethane-Mini spectrometers, employing recently available mid-infrared distributed feedback tunable diode lasers (DFB-TDL), provide 1 s ethane measurements with sub-ppb precision. In this work, an Ethane-Mini spectrometer has been integrated into two mobile sampling platforms, a ground vehicle and a small airplane, and used to measure ethane/methane enhancement ratios downwind of methane sources. Methane emissions with precisely known sources are shown to have ethane/methane enhancement ratios that differ greatly depending on the source type. Large differences between biogenic and thermogenic sources are observed. Variation within thermogenic sources are detected and tabulated. Methane emitters are classified by their expected ethane content. Categories include the following: biogenic (6%), pipeline grade natural gas (30%). Regional scale observations in the Dallas/Fort Worth area of Texas show two distinct ethane/methane enhancement ratios bridged by a transitional region. These results demonstrate the usefulness of continuous and fast ethane measurements in experimental studies of methane emissions, particularly in the oil and natural gas sector.

  15. Acquisition of HPLC-Mass Spectrometer

    Science.gov (United States)

    2015-08-18

    31-Jan-2015 Approved for Public Release; Distribution Unlimited Final Report: Acquisition of HPLC -Mass Spectrometer The views, opinions and/or findings...published in peer-reviewed journals: Final Report: Acquisition of HPLC -Mass Spectrometer Report Title The acquisition of the mass spectrometer has been a

  16. Quantum independent increment processes

    CERN Document Server

    Franz, Uwe

    2005-01-01

    This volume is the first of two volumes containing the revised and completed notes lectures given at the school "Quantum Independent Increment Processes: Structure and Applications to Physics". This school was held at the Alfried-Krupp-Wissenschaftskolleg in Greifswald during the period March 9 – 22, 2003, and supported by the Volkswagen Foundation. The school gave an introduction to current research on quantum independent increment processes aimed at graduate students and non-specialists working in classical and quantum probability, operator algebras, and mathematical physics. The present first volume contains the following lectures: "Lévy Processes in Euclidean Spaces and Groups" by David Applebaum, "Locally Compact Quantum Groups" by Johan Kustermans, "Quantum Stochastic Analysis" by J. Martin Lindsay, and "Dilations, Cocycles and Product Systems" by B.V. Rajarama Bhat.

  17. Fourier Transform Spectrometer System

    Science.gov (United States)

    Campbell, Joel F. (Inventor)

    2014-01-01

    A Fourier transform spectrometer (FTS) data acquisition system includes an FTS spectrometer that receives a spectral signal and a laser signal. The system further includes a wideband detector, which is in communication with the FTS spectrometer and receives the spectral signal and laser signal from the FTS spectrometer. The wideband detector produces a composite signal comprising the laser signal and the spectral signal. The system further comprises a converter in communication with the wideband detector to receive and digitize the composite signal. The system further includes a signal processing unit that receives the composite signal from the converter. The signal processing unit further filters the laser signal and the spectral signal from the composite signal and demodulates the laser signal, to produce velocity corrected spectral data.

  18. Incremental short daily home hemodialysis: a case series.

    Science.gov (United States)

    Toth-Manikowski, Stephanie M; Mullangi, Surekha; Hwang, Seungyoung; Shafi, Tariq

    2017-07-05

    Patients starting dialysis often have substantial residual kidney function. Incremental hemodialysis provides a hemodialysis prescription that supplements patients' residual kidney function while maintaining total (residual + dialysis) urea clearance (standard Kt/Vurea) targets. We describe our experience with incremental hemodialysis in patients using NxStage System One for home hemodialysis. From 2011 to 2015, we initiated 5 incident hemodialysis patients on an incremental home hemodialysis regimen. The biochemical parameters of all patients remained stable on the incremental hemodialysis regimen and they consistently achieved standard Kt/Vurea targets. Of the two patients with follow-up >6 months, residual kidney function was preserved for ≥2 years. Importantly, the patients were able to transition to home hemodialysis without automatically requiring 5 sessions per week at the outset and gradually increased the number of treatments and/or dialysate volume as the residual kidney function declined. An incremental home hemodialysis regimen can be safely prescribed and may improve acceptability of home hemodialysis. Reducing hemodialysis frequency by even one treatment per week can reduce the number of fistula or graft cannulations or catheter connections by >100 per year, an important consideration for patient well-being, access longevity, and access-related infections. The incremental hemodialysis approach, supported by national guidelines, can be considered for all home hemodialysis patients with residual kidney function.

  19. Applications of Silicon-on-Insulator Photonic Crystal Structures in Miniature Spectrometer Designs

    Science.gov (United States)

    Gao, Boshen

    Optical spectroscopy is one of the most important fundamental scientific techniques. It has been widely adopted in physics, chemistry, biology, medicine and many other research fields. However, the size and weight of a spectrometer as well as the difficulty to align and maintain it have long limited spectroscopy to be a laboratory-only procedure. With the recent advancement in semiconductor electronics and photonics, miniaturized spectrometers have been introduced to complete many tasks in daily life where mobility and portability are necessary. This thesis focuses on the study of several photonic crystal (PC) nano-structures potentially suitable for miniaturized on-chip spectrometer designs. Chapter 1 briefly introduces the concept of PCs and their band structures. By analyzing the band structure, the origin of the superprism effect is explained. Defect-based PC nano-cavities are also discussed, as well as a type of coupled cavity waveguides (CCW) composed of PC nano-cavities. Chapter 2 is devoted to the optimization of a flat-band superprism structure for spectroscopy application using numerical simulations. Chapter 3 reports a fabricated broad-band superprism and the experimental characterization of its wavelength resolving performance. In chapter 4, the idea of composing a miniature spectrometer based on a single tunable PC nano-cavity is proposed. The rest of this chapter discusses the experimental study of this design. Chapter 5 examines the slow-light performance of a CCW and discusses its potential application in slow-light interferometry. Chapter 6 serves as a conclusion of this thesis and proposes directions for possible future work to follow up.

  20. Digital positron annihilation spectrometer

    International Nuclear Information System (INIS)

    Cheng Bin; Weng Huimin; Han Rongdian; Ye Bangjiao

    2010-01-01

    With the high speed development of digital signal process, the technique of the digitization and processing of signals was applied in the domain of a broad class of nuclear technique. The development of digital positron lifetime spectrometer (DPLS) is more promising than the conventional positron lifetime spectrometer equipped with nuclear instrument modules. And digital lifetime spectrometer has many advantages, such as low noise, long term stability, flexible online or offline digital processing, simple setup, low expense, easy to setting, and more physical information. Digital constant fraction discrimination is for timing. And a new method of optimizing energy windows setting for digital positron lifetime spectrometer is also developed employing the simulated annealing for the convenient use. The time resolution is 220ps and the count rate is 200cps. (authors)

  1. Quantum independent increment processes

    CERN Document Server

    Franz, Uwe

    2006-01-01

    This is the second of two volumes containing the revised and completed notes of lectures given at the school "Quantum Independent Increment Processes: Structure and Applications to Physics". This school was held at the Alfried-Krupp-Wissenschaftskolleg in Greifswald in March, 2003, and supported by the Volkswagen Foundation. The school gave an introduction to current research on quantum independent increment processes aimed at graduate students and non-specialists working in classical and quantum probability, operator algebras, and mathematical physics. The present second volume contains the following lectures: "Random Walks on Finite Quantum Groups" by Uwe Franz and Rolf Gohm, "Quantum Markov Processes and Applications in Physics" by Burkhard Kümmerer, Classical and Free Infinite Divisibility and Lévy Processes" by Ole E. Barndorff-Nielsen, Steen Thorbjornsen, and "Lévy Processes on Quantum Groups and Dual Groups" by Uwe Franz.

  2. Growth increments in teeth of Diictodon (Therapsida

    Directory of Open Access Journals (Sweden)

    J. Francis Thackeray

    1991-09-01

    Full Text Available Growth increments circa 0.02 mm in width have been observed in sectioned tusks of Diictodon from the Late Permian lower Beaufort succession of the South African Karoo, dated between about 260 and 245 million years ago. Mean growth increments show a decline from relatively high values in the Tropidostoma/Endothiodon Assemblage Zone, to lower values in the Aulacephalodon/Cistecephaluszone, declining still further in the Dicynodon lacerficeps/Whaitsia zone at the end of the Permian. These changes coincide with gradual changes in carbon isotope ratios measured from Diictodon tooth apatite. It is suggested that the decline in growth increments is related to environmental changes associated with a decline in primary production which contributed to the decline in abundance and ultimate extinction of Diictodon.

  3. Incremental Integrity Checking: Limitations and Possibilities

    DEFF Research Database (Denmark)

    Christiansen, Henning; Martinenghi, Davide

    2005-01-01

    Integrity checking is an essential means for the preservation of the intended semantics of a deductive database. Incrementality is the only feasible approach to checking and can be obtained with respect to given update patterns by exploiting query optimization techniques. By reducing the problem...... to query containment, we show that no procedure exists that always returns the best incremental test (aka simplification of integrity constraints), and this according to any reasonable criterion measuring the checking effort. In spite of this theoretical limitation, we develop an effective procedure...

  4. Simulation of the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Cox, D.M.; Herzberg, R.D. [University of Liverpool, Department of Physics, Oliver Lodge Laboratory, Liverpool (United Kingdom); Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J. [University of Jyvaeskylae, Department of Physics, Jyvaeskylae (Finland); Hauschild, K. [Universite Paris-Sud, CSNSM-IN2P3-CNRS, Orsay (France)

    2015-06-15

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  5. Simulation of the SAGE spectrometer

    International Nuclear Information System (INIS)

    Cox, D.M.; Herzberg, R.D.; Konki, J.; Greenlees, P.T.; Pakarinen, J.; Papadakis, P.; Rahkila, P.; Sandzelius, M.; Sorri, J.; Hauschild, K.

    2015-01-01

    The SAGE spectrometer combines a Ge-detector array with a Si detector to allow simultaneous detection of γ-rays and electrons. A comprehensive GEANT4 simulation package of the SAGE spectrometer has been developed with the ability to simulate the expected datasets based on user input files. The measured performance of the spectrometer is compared to the results obtained from the simulations. (orig.)

  6. Mobile Learning Practice In Higher Education in Nepal

    Directory of Open Access Journals (Sweden)

    Krishna Prasad Parajuli

    2016-03-01

    Full Text Available During the 15 years of this current century, mobile technology has become a leading technology in the support of educational outcomes. This study investigated the mobile learning practices among undergraduates in higher education in the semi-urban and rural areas of the Gorkha district of Nepal. The objectives were to explore the availability of mobile technology for learning; its costs; learning trends, institutional policies, and attitudes towards mobile learning. These factors were explored to identify implications for pedagogical practice. The study adopted a mixed methods design, in which the quantitative data were collected by using a questionnaire with a sample of 161 undergraduates from six campuses. The qualitative data were collected from 19 purposively selected respondents by the way of semi-structured interviews. The result indicated that virtually all undergraduates possessed their mobile phones and used them informally for learning both inside and outside of their classes. The majority of the students had positive attitudes towards mobile learning. However, many were not satisfied with the effectiveness of their practices or with the level of institutional support for using mobile devices to support their learning. Although comprehensive mobile learning is not widespread in Nepal, enriching conventional learning by the incremental use of mobile devices is possible in Nepalese institutes of higher education. I conclude that teachers and institutions should provide guidance to students about the effective uses of mobile technology because successful use of technology in learning largely depends on appropriate pedagogy and teacher support.

  7. Design of methodology for incremental compiler construction

    Directory of Open Access Journals (Sweden)

    Pavel Haluza

    2011-01-01

    Full Text Available The paper deals with possibilities of the incremental compiler construction. It represents the compiler construction possibilities for languages with a fixed set of lexical units and for languages with a variable set of lexical units, too. The methodology design for the incremental compiler construction is based on the known algorithms for standard compiler construction and derived for both groups of languages. Under the group of languages with a fixed set of lexical units there belong languages, where each lexical unit has its constant meaning, e.g., common programming languages. For this group of languages the paper tries to solve the problem of the incremental semantic analysis, which is based on incremental parsing. In the group of languages with a variable set of lexical units (e.g., professional typographic system TEX, it is possible to change arbitrarily the meaning of each character on the input file at any time during processing. The change takes effect immediately and its validity can be somehow limited or is given by the end of the input. For this group of languages this paper tries to solve the problem case when we use macros temporarily changing the category of arbitrary characters.

  8. 21 CFR 874.1070 - Short increment sensitivity index (SISI) adapter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Short increment sensitivity index (SISI) adapter. 874.1070 Section 874.1070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... increment sensitivity index (SISI) adapter. (a) Identification. A short increment sensitivity index (SISI...

  9. A Syntactic-Semantic Approach to Incremental Verification

    OpenAIRE

    Bianculli, Domenico; Filieri, Antonio; Ghezzi, Carlo; Mandrioli, Dino

    2013-01-01

    Software verification of evolving systems is challenging mainstream methodologies and tools. Formal verification techniques often conflict with the time constraints imposed by change management practices for evolving systems. Since changes in these systems are often local to restricted parts, an incremental verification approach could be beneficial. This paper introduces SiDECAR, a general framework for the definition of verification procedures, which are made incremental by the framework...

  10. Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications.

    Science.gov (United States)

    Trzcinski, Peter; Weagant, Scott; Karanassios, Vassili

    2016-05-01

    Wireless data acquisition using smartphones or handhelds offers increased mobility, it provides reduced size and weight, it has low electrical power requirements, and (in some cases) it has an ability to access the internet. Thus, it is well suited for mobile spectrometry applications using miniaturized, field-portable spectrometers, or detectors for chemical analysis in the field (i.e., on-site). There are four main wireless communications standards that can be used for wireless data acquisition, namely ZigBee, Bluetooth, Wi-Fi, and UWB (ultra-wide band). These are briefly reviewed and are evaluated for applicability to data acquisition of transient signals (i.e., time-domain) in the field (i.e., on-site) from a miniaturized, field-portable photomultiplier tube detector and from a photodiode array detector installed in a miniaturized, field-portable fiber optic spectrometer. These are two of the most widely used detectors for optical measurements in the ultraviolet-visible range of the spectrum. A miniaturized, 3D-printed, battery-operated microplasma-on-a-chip was used for generation of transient optical emission signals. Elemental analysis from liquid microsamples, a microplasma, and a handheld or a smartphone will be used as examples. Development and potential applicability of wireless data acquisition of transient optical emission signals for taking part of the lab to the sample types of mobile, field-portable spectrometry applications will be discussed. The examples presented are drawn from past and ongoing work in the authors' laboratory. A handheld or a smartphone were used as the mobile computing devices of choice. © The Author(s) 2016.

  11. Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.

    Science.gov (United States)

    Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J

    2016-08-01

    Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.

  12. The MEG positron spectrometer

    International Nuclear Information System (INIS)

    Nishiguchi, Hajime

    2007-01-01

    We have been developing an innovative spectrometer for the MEG experiment at the Paul Scherrer Institute (PSI) in Switzerland. This experiment searches for a lepton flavour violating decay μ + →e + γ with a sensitivity of 10 -13 in order to explore the region predicted by supersymmetric extensions of the standard model. The MEG positron spectrometer consists of a specially designed superconducting solenoidal magnet with a highly graded field, an ultimate low-mass drift chamber system, and a precise time measuring counter system. This innovative positron spectrometer is described here focusing on the drift chamber system

  13. VEGAS: VErsatile GBT Astronomical Spectrometer

    Science.gov (United States)

    Bussa, Srikanth; VEGAS Development Team

    2012-01-01

    The National Science Foundation Advanced Technologies and Instrumentation (NSF-ATI) program is funding a new spectrometer backend for the Green Bank Telescope (GBT). This spectrometer is being built by the CICADA collaboration - collaboration between the National Radio Astronomy Observatory (NRAO) and the Center for Astronomy Signal Processing and Electronics Research (CASPER) at the University of California Berkeley.The backend is named as VErsatile GBT Astronomical Spectrometer (VEGAS) and will replace the capabilities of the existing spectrometers. This backend supports data processing from focal plane array systems. The spectrometer will be capable of processing up to 1.25 GHz bandwidth from 8 dual polarized beams or a bandwidth up to 10 GHz from a dual polarized beam.The spectrometer will be using 8-bit analog to digital converters (ADC), which gives a better dynamic range than existing GBT spectrometers. There will be 8 tunable digital sub-bands within the 1.25 GHz bandwidth, which will enhance the capability of simultaneous observation of multiple spectral transitions. The maximum spectral dump rate to disk will be about 0.5 msec. The vastly enhanced backend capabilities will support several science projects with the GBT. The projects include mapping temperature and density structure of molecular clouds; searches for organic molecules in the interstellar medium; determination of the fundamental constants of our evolving Universe; red-shifted spectral features from galaxies across cosmic time and survey for pulsars in the extreme gravitational environment of the Galactic Center.

  14. Shredder: GPU-Accelerated Incremental Storage and Computation

    OpenAIRE

    Bhatotia, Pramod; Rodrigues, Rodrigo; Verma, Akshat

    2012-01-01

    Redundancy elimination using data deduplication and incremental data processing has emerged as an important technique to minimize storage and computation requirements in data center computing. In this paper, we present the design, implementation and evaluation of Shredder, a high performance content-based chunking framework for supporting incremental storage and computation systems. Shredder exploits the massively parallel processing power of GPUs to overcome the CPU bottlenecks of content-ba...

  15. Magnetic spectrometer Grand Raiden

    International Nuclear Information System (INIS)

    Fujiwara, M.; Akimune, H.; Daito, I.; Fujimura, H.; Fujita, Y.; Hatanaka, K.; Ikegami, H.; Katayama, I.; Nagayama, K.; Matsuoka, N.; Morinobu, S.; Noro, T.; Yoshimura, M.; Sakaguchi, H.; Sakemi, Y.; Tamii, A.; Yosoi, M.

    1999-01-01

    A high-resolution magnetic spectrometer called 'Grand Raiden' is operated at the RCNP ring cyclotron facility in Osaka for nuclear physics studies at intermediate energies. This magnetic spectrometer has excellent ion-optical properties. In the design of the spectrometer, the second-order dispersion matching condition has been taken into account, and almost all the aberration terms such as (x vertical bar θ 3 ), (x vertical bar θφ 2 ), (x vertical bar θ 2 δ) and (x vertical bar θδ 2 ) in a third-order matrix calculation are optimized. A large magnetic rigidity of the spectrometer (K = 1400 MeV) gives a great advantage to measure the charge-exchange ( 3 He, t) reactions at 450 MeV. The ability of the high-resolution measurement has been demonstrated. Various coincidence measurements are performed to study the nuclear structures of highly excited states through decay properties of nuclear levels following nuclear reactions at intermediate energies

  16. RITA-type triple axis spectrometers

    International Nuclear Information System (INIS)

    Roennow, H.M.

    2001-01-01

    The RITA spectrometer at Risoe National Laboratory was the first to incorporate a complete re-thinking of the neutron-path from source, through detector to analysis. Since then, other RITA-type spectrometers such as SPINS at NIST, RITA-II at PSI have been built, and several new spectrometers around the world are adapting the same philosophy. The main novelty of RITA was the introduction of a single back-end tank featuring both an analyser block with multiple individually turnable analyser blades and a 2D position sensitive detector. Several new triple-axis spectrometers are presently being built at existing and future sources, and almost all of them have learnt from the experience with RITA. (R.P.)

  17. Characterization of ion processes in a GC/DMS air quality monitor by integration of the instrument to a mass spectrometer.

    Science.gov (United States)

    Limero, T F; Nazarov, E G; Menlyadiev, M; Eiceman, G A

    2015-02-07

    The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in air, a thermal desorber before the GC column, a differential mobility spectrometer (DMS), and another DMS as an atmospheric pressure ionization source for the MS. Return flow to the internally recirculated air system of the AQM's DMS was replenished using purified air. Although ions and unreacted neutral vapors flowed from the detector through Viton® tubing into the source of the MS, ions were not detected in the MS without the auxillary ion source, (63)Ni as in the mobility detector. The GC-DMS-MS instrument provided a 3-D measurement platform (GC, DMS, and MS analysis) to explore the gas composition inside the GC-DMS recirculation loop and provide DMS-MS measurement of the components of a complex VOC mixture with performance significantly enhanced by mass-analysis, either with mass spectral scans or with an extracted ion chromatogram. This combination of a mobility spectrometer and a mass spectrometer was possible as vapors and ions are carried together through the DMS analyzer, thereby preserving the chromatographic separation efficiency. The critical benefit of this instrument concept is that all flows in and through the thoroughly integrated GC-DMS analyzer are kept intact allowing a full measure of the ion and vapor composition in the complete system. Performance has been evaluated using a synthetic air sample and a sample of airborne vapors in a laboratory. Capabilities and performance values are described using results from AQM-MS analysis of purified air, ambient air from a research laboratory in a chemistry building, and a sample of synthetic air of known composition

  18. Non-destructive in situ study of “Mad Meg” by Pieter Bruegel the Elder using mobile X-ray fluorescence, X-ray diffraction and Raman spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Van de Voorde, Lien, E-mail: lien.vandevoorde@ugent.be [Ghent University, Department of Analytical Chemistry, X-ray Microspectroscopy and Imaging Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); Van Pevenage, Jolien [Ghent University, Department of Analytical Chemistry, Raman Spectroscopy Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); De Langhe, Kaat [Ghent University, Department of Archaeology, Archaeometry Research Group, Sint-Pietersnieuwstraat 35, B-9000 Gent (Belgium); De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo [Ghent University, Department of Analytical Chemistry, X-ray Microspectroscopy and Imaging Research Group, Krijgslaan 281 S12, B-9000 Gent (Belgium); Vandenabeele, Peter [Ghent University, Department of Archaeology, Archaeometry Research Group, Sint-Pietersnieuwstraat 35, B-9000 Gent (Belgium); Martens, Maximiliaan P.J. [Ghent University, Department of Art, Music and Theatre Sciences, Blandijnberg 2, B-9000 Gent (Belgium)

    2014-07-01

    “Mad Meg”, a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO{sub 2} + 15% K{sub 2}O + 10% CoO + 5% Al{sub 2}O{sub 3}) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel. - Highlights: • In situ, non-destructive investigation of a famous painting by Pieter Bruegel. • Use of a new, commercial available, portable XRF/XRD instrumentation. • Multi-methodological approach: make also use of a mobile Raman spectrometer. • Used pigments and different preparation layers of the painting are characterized. • The verification of two important historical iconographic hypotheses are performed.

  19. Non-destructive in situ study of “Mad Meg” by Pieter Bruegel the Elder using mobile X-ray fluorescence, X-ray diffraction and Raman spectrometers

    International Nuclear Information System (INIS)

    Van de Voorde, Lien; Van Pevenage, Jolien; De Langhe, Kaat; De Wolf, Robin; Vekemans, Bart; Vincze, Laszlo; Vandenabeele, Peter; Martens, Maximiliaan P.J.

    2014-01-01

    “Mad Meg”, a figure of Flemish folklore, is the subject of a famous oil-on-panel painting by the Flemish renaissance artist Pieter Bruegel the Elder, exhibited in the Museum Mayer van den Bergh (Antwerp, Belgium). This article reports on the in situ chemical characterization of this masterpiece by using currently available state-of-the-art portable analytical instruments. The applied non-destructive analytical approach involved the use of a) handheld X-ray fluorescence instrumentation for retrieving elemental information and b) portable X-ray fluorescence/X-ray diffraction instrumentation and laser-based Raman spectrometers for obtaining structural/molecular information. Next to material characterization of the used pigments and of the different preparation layers of the painting, also the verification of two important historical iconographic hypotheses is performed concerning the economic way of painting by Brueghel, and whether or not he used blue smalt pigment for painting the boat that appears towards the top of the painting. The pigments identified are smalt pigment (65% SiO 2 + 15% K 2 O + 10% CoO + 5% Al 2 O 3 ) for the blue color present in all blue areas of the painting, probably copper resinate for the green colors, vermillion (HgS) as red pigment and lead white is used to form different colors. The comparison of blue pigments used on different areas of the painting gives no differences in the elemental fingerprint which confirms the existing hypothesis concerning the economic painting method by Bruegel. - Highlights: • In situ, non-destructive investigation of a famous painting by Pieter Bruegel. • Use of a new, commercial available, portable XRF/XRD instrumentation. • Multi-methodological approach: make also use of a mobile Raman spectrometer. • Used pigments and different preparation layers of the painting are characterized. • The verification of two important historical iconographic hypotheses are performed

  20. Simulation and comparison of perturb and observe and incremental ...

    Indian Academy of Sciences (India)

    Perturb and Observe (P & O) algorithm and Incremental conductance algorithm. ... Keywords. Solar array; insolation; MPPT; modelling, P & O; incremental conductance. 1. .... voltage level. It is also ..... Int. J. Advances in Eng. Technol. 133–148.

  1. Software for mass spectrometer control

    International Nuclear Information System (INIS)

    Curuia, Marian; Culcer, Mihai; Anghel, Mihai; Iliescu, Mariana; Trancota, Dan; Kaucsar, Martin; Oprea, Cristiana

    2004-01-01

    The paper describes a software application for the MAT 250 mass spectrometer control, which was refurbished. The spectrometer was bring-up-to-date using a hardware structure on its support where the software application for mass spectrometer control was developed . The software application is composed of dedicated modules that perform given operations. The instructions that these modules have to perform are generated by a principal module. This module makes possible the change of information between the modules that compose the software application. The use of a modal structure is useful for adding new functions in the future. The developed application in our institute made possible the transformation of the mass spectrometer MAT 250 into a device endowed with other new generation tools. (authors)

  2. [Dynamic changes of surface soil organic carbon and light-fraction organic carbon after mobile dune afforestation with Mongolian pine in Horqin Sandy Land].

    Science.gov (United States)

    Shang, Wen; Li, Yu-qiang; Wang, Shao-kun; Feng, Jing; Su, Na

    2011-08-01

    This paper studied the dynamic changes of surface (0-15 cm) soil organic carbon (SOC) and light-fraction organic carbon (LFOC) in 25- and 35-year-old sand-fixing Mongolian pine (Pinus sylvestris var. mongolica) plantations in Horqin Sandy Land, with a mobile dune as a comparison site. After the afforestation on mobile dune, the content of coarse sand in soil decreased, while that of fine sand and clay-silt increased significantly. The SOC and LFOC contents also increased significantly, but tended to decrease with increasing soil depth. Afforestation increased the storages of SOC and LFOC in surface soil, and the increment increased with plantation age. In the two plantations, the increment of surface soil LFOC storage was much higher than that of SOC storage, suggesting that mobile dune afforestation had a larger effect on surface soil LFOC than on SOC.

  3. Mass spectrometers in medicine

    International Nuclear Information System (INIS)

    Bushman, J.A.

    1975-01-01

    This paper describes how the mass spectrometer enables true lung function, namely the exchange of gases between the environment and the organism, to be measured. This has greatly improved the understanding of respiratory disease and the latest generation of respiratory mass spectrometers will do much to increase the application of the technique. (author)

  4. Efficient incremental relaying

    KAUST Repository

    Fareed, Muhammad Mehboob

    2013-07-01

    We propose a novel relaying scheme which improves the spectral efficiency of cooperative diversity systems by utilizing limited feedback from destination. Our scheme capitalizes on the fact that relaying is only required when direct transmission suffers deep fading. We calculate the packet error rate for the proposed efficient incremental relaying scheme with both amplify and forward and decode and forward relaying. Numerical results are also presented to verify their analytical counterparts. © 2013 IEEE.

  5. Entity versus incremental theories predict older adults' memory performance.

    Science.gov (United States)

    Plaks, Jason E; Chasteen, Alison L

    2013-12-01

    The authors examined whether older adults' implicit theories regarding the modifiability of memory in particular (Studies 1 and 3) and abilities in general (Study 2) would predict memory performance. In Study 1, individual differences in older adults' endorsement of the "entity theory" (a belief that one's ability is fixed) or "incremental theory" (a belief that one's ability is malleable) of memory were measured using a version of the Implicit Theories Measure (Dweck, 1999). Memory performance was assessed with a free-recall task. Results indicated that the higher the endorsement of the incremental theory, the better the free recall. In Study 2, older and younger adults' theories were measured using a more general version of the Implicit Theories Measure that focused on the modifiability of abilities in general. Again, for older adults, the higher the incremental endorsement, the better the free recall. Moreover, as predicted, implicit theories did not predict younger adults' memory performance. In Study 3, participants read mock news articles reporting evidence in favor of either the entity or incremental theory. Those in the incremental condition outperformed those in the entity condition on reading span and free-recall tasks. These effects were mediated by pretask worry such that, for those in the entity condition, higher worry was associated with lower performance. Taken together, these studies suggest that variation in entity versus incremental endorsement represents a key predictor of older adults' memory performance. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  6. Routing Protocol for Mobile Ad-hoc Wireless Networks

    Directory of Open Access Journals (Sweden)

    I. M. B. Nogales

    2007-09-01

    Full Text Available Bluetooth is a cutting-edge technology used for implementing wireless ad hoc networks. In order to provide an overall scheme for mobile ad hoc networks, this paper deals with scatternet topology formation and routing algorithm to form larger ad hoc wireless Networks. Scatternet topology starts by forming a robust network, which is less susceptible to the problems posed by node mobility. Mobile topology relies on the presence of free nodes that create multiple connections with the network and on their subsequently rejoining the network. Our routing protocol is a proactive routing protocol, which is tailor made for the Bluetooth ad hoc network. The connection establishment connects nodes in a structure that simplifies packet routing and scheduling. The design allows nodes to arrive and leave arbitrarily, incrementally building the topology and healing partitions when they occur. We present simulation results that show that the algorithm presents low formation latency and also generates an efficient topology for forwarding packets along ad-hoc wireless networks.

  7. Lifetime costs of lung transplantation : Estimation of incremental costs

    NARCIS (Netherlands)

    VanEnckevort, PJ; Koopmanschap, MA; Tenvergert, EM; VanderBij, W; Rutten, FFH

    1997-01-01

    Despite an expanding number of centres which provide lung transplantation, information about the incremental costs of lung transplantation is scarce. From 1991 until 1995, in The Netherlands a technology assessment was performed which provided information about the incremental costs of lung

  8. Electron spectrometer for gas-phase spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bozek, J.D.; Schlachter, A.S. [Ernest Orlando Lawrence Berkeley National Lab., CA (United States)

    1997-04-01

    An electron spectrometer for high-resolution spectroscopy of gaseous samples using synchrotron radiation has been designed and constructed. The spectrometer consists of a gas cell, cylindrical electrostatic lens, spherical-sector electron energy analyzer, position-sensitive detector and associated power supplies, electronics and vacuum pumps. Details of the spectrometer design are presented together with some representative spectra.

  9. Defense Agencies Initiative Increment 2 (DAI Inc 2)

    Science.gov (United States)

    2016-03-01

    module. In an ADM dated September 23, 2013, the MDA established Increment 2 as a MAIS program to include budget formulation; grants financial...2016 Major Automated Information System Annual Report Defense Agencies Initiative Increment 2 (DAI Inc 2) Defense Acquisition Management...President’s Budget RDT&E - Research, Development, Test, and Evaluation SAE - Service Acquisition Executive TBD - To Be Determined TY - Then

  10. Biometrics Enabling Capability Increment 1 (BEC Inc 1)

    Science.gov (United States)

    2016-03-01

    modal biometrics submissions to include iris, face, palm and finger prints from biometrics collection devices, which will support the Warfighter in...2016 Major Automated Information System Annual Report Biometrics Enabling Capability Increment 1 (BEC Inc 1) Defense Acquisition Management...Phone: 227-3119 DSN Fax: Date Assigned: July 15, 2015 Program Information Program Name Biometrics Enabling Capability Increment 1 (BEC Inc 1) DoD

  11. 76 FR 53763 - Immigration Benefits Business Transformation, Increment I

    Science.gov (United States)

    2011-08-29

    ..., 100, et al. Immigration Benefits Business Transformation, Increment I; Final Rule #0;#0;Federal... Benefits Business Transformation, Increment I AGENCY: U.S. Citizenship and Immigration Services, DHS... USCIS is engaged in an enterprise-wide transformation effort to implement new business processes and to...

  12. Shakedown analysis by finite element incremental procedures

    International Nuclear Information System (INIS)

    Borkowski, A.; Kleiber, M.

    1979-01-01

    It is a common occurence in many practical problems that external loads are variable and the exact time-dependent history of loading is unknown. Instead of it load is characterized by a given loading domain: a convex polyhedron in the n-dimensional space of load parameters. The problem is then to check whether a structure shakes down, i.e. responds elastically after a few elasto-plastic cycles, or not to a variable loading as defined above. Such check can be performed by an incremental procedure. One should reproduce incrementally a simple cyclic process which consists of proportional load paths that connect the origin of the load space with the corners of the loading domain. It was proved that if a structure shakes down to such loading history then it is able to adopt itself to an arbitrary load path contained in the loading domain. The main advantage of such approach is the possibility to use existing incremental finite-element computer codes. (orig.)

  13. Whirlpool routing for mobility

    KAUST Repository

    Lee, Jung Woo

    2010-01-01

    We present the Whirlpool Routing Protocol (WARP), which efficiently routes data to a node moving within a static mesh. The key insight in WARP\\'s design is that data traffic can use an existing routing gradient to efficiently probe the topology, repair the routing gradient, and communicate these repairs to nearby nodes. Using simulation, controlled testbeds, and real mobility experiments, we find that using the data plane for topology maintenance is highly effective due to the incremental nature of mobility updates. WARP leverages the fact that converging flows at a destination make the destination have the region of highest traffic. We provide a theoretical basis for WARP\\'s behavior, defining an "update area" in which the topology must adjust when a destination moves. As long as packets arrive at a destination before it moves outside of the update area, WARP can repair the topology using the data plane. Compared to existing protocols, such as DYMO and HYPER, WARP\\'s packet drop rate is up to 90% lower while sending up to 90% fewer packets.

  14. Spectrometers for compact neutron sources

    Science.gov (United States)

    Voigt, J.; Böhm, S.; Dabruck, J. P.; Rücker, U.; Gutberlet, T.; Brückel, T.

    2018-03-01

    We discuss the potential for neutron spectrometers at novel accelerator driven compact neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear reactions, which enable cryogenic moderators in very close proximity to the target and neutron optics at comparably short distances from the moderator compared to existing sources. While the first effect aims at increasing the phase space density of a moderator, the second allows the extraction of a large phase space volume, which is typically requested for spectrometer applications. We find that competitive spectrometers can be realized if (a) the neutron production rate can be synchronized with the experiment repetition rate and (b) the emission characteristics of the moderator can be matched to the phase space requirements of the experiment. MCNP simulations for protons or deuterons on a Beryllium target with a suitable target/moderator design yield a source brightness, from which we calculate the sample fluxes by phase space considerations for different types of spectrometers. These match closely the figures of todays spectrometers at medium flux sources. Hence we conclude that compact neutron sources might be a viable option for next generation neutron sources.

  15. Lessons learned with the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J; Greenlees, P T; Jones, P; Julin, R; Konki, J; Pakarinen, J; Rahkila, P; Sandzelius, M; Uusitalo, J; Papadakis, P; Cox, D M; Herzberg, R D

    2012-01-01

    The SAGE spectrometer combines a high-efficiency γ-ray detection system with an electron spectrometer. Some of the design features have been known to be problematic and surprises have come up during the early implementation of the spectrometer. Tests related to bismuth germanate Compton-suppression shields, electron detection efficiency and an improved cooling system are discussed in the paper. (paper)

  16. Automatic incrementalization of Prolog based static analyses

    DEFF Research Database (Denmark)

    Eichberg, Michael; Kahl, Matthias; Saha, Diptikalyan

    2007-01-01

    Modem development environments integrate various static analyses into the build process. Analyses that analyze the whole project whenever the project changes are impractical in this context. We present an approach to automatic incrementalization of analyses that are specified as tabled logic...... programs and evaluated using incremental tabled evaluation, a technique for efficiently updating memo tables in response to changes in facts and rules. The approach has been implemented and integrated into the Eclipse IDE. Our measurements show that this technique is effective for automatically...

  17. Community Core Evolution in Mobile Social Networks

    Directory of Open Access Journals (Sweden)

    Hao Xu

    2013-01-01

    Full Text Available Community detection in social networks attracts a lot of attention in the recent years. Existing methods always depict the relationship of two nodes using the temporary connection. However, these temporary connections cannot be fully recognized as the real relationships when the history connections among nodes are considered. For example, a casual visit in Facebook cannot be seen as an establishment of friendship. Hence, our question is the following: how to cluster the real friends in mobile social networks? In this paper, we study the problem of detecting the stable community core in mobile social networks. The cumulative stable contact is proposed to depict the relationship among nodes. The whole process is divided into timestamps. Nodes and their connections can be added or removed at each timestamp, and historical contacts are considered when detecting the community core. Also, community cores can be tracked through the incremental computing, which can help to recognize the evolving of community structure. Empirical studies on real-world social networks demonstrate that our proposed method can effectively detect stable community cores in mobile social networks.

  18. Community core evolution in mobile social networks.

    Science.gov (United States)

    Xu, Hao; Xiao, Weidong; Tang, Daquan; Tang, Jiuyang; Wang, Zhenwen

    2013-01-01

    Community detection in social networks attracts a lot of attention in the recent years. Existing methods always depict the relationship of two nodes using the temporary connection. However, these temporary connections cannot be fully recognized as the real relationships when the history connections among nodes are considered. For example, a casual visit in Facebook cannot be seen as an establishment of friendship. Hence, our question is the following: how to cluster the real friends in mobile social networks? In this paper, we study the problem of detecting the stable community core in mobile social networks. The cumulative stable contact is proposed to depict the relationship among nodes. The whole process is divided into timestamps. Nodes and their connections can be added or removed at each timestamp, and historical contacts are considered when detecting the community core. Also, community cores can be tracked through the incremental computing, which can help to recognize the evolving of community structure. Empirical studies on real-world social networks demonstrate that our proposed method can effectively detect stable community cores in mobile social networks.

  19. Mission Planning System Increment 5 (MPS Inc 5)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Mission Planning System Increment 5 (MPS Inc 5) Defense Acquisition Management Information...President’s Budget RDT&E - Research, Development, Test, and Evaluation SAE - Service Acquisition Executive TBD - To Be Determined TY - Then Year...Phone: 845-9625 DSN Fax: Date Assigned: May 19, 2014 Program Information Program Name Mission Planning System Increment 5 (MPS Inc 5) DoD

  20. MRI: Modular reasoning about interference in incremental programming

    OpenAIRE

    Oliveira, Bruno C. D. S; Schrijvers, Tom; Cook, William R

    2012-01-01

    Incremental Programming (IP) is a programming style in which new program components are defined as increments of other components. Examples of IP mechanisms include: Object-oriented programming (OOP) inheritance, aspect-oriented programming (AOP) advice and feature-oriented programming (FOP). A characteristic of IP mechanisms is that, while individual components can be independently defined, the composition of components makes those components become tightly coupled, sh...

  1. Incremental short daily home hemodialysis: a case series

    OpenAIRE

    Toth-Manikowski, Stephanie M.; Mullangi, Surekha; Hwang, Seungyoung; Shafi, Tariq

    2017-01-01

    Background Patients starting dialysis often have substantial residual kidney function. Incremental hemodialysis provides a hemodialysis prescription that supplements patients? residual kidney function while maintaining total (residual + dialysis) urea clearance (standard Kt/Vurea) targets. We describe our experience with incremental hemodialysis in patients using NxStage System One for home hemodialysis. Case presentation From 2011 to 2015, we initiated 5 incident hemodialysis patients on an ...

  2. High resolution solar soft X-ray spectrometer

    International Nuclear Information System (INIS)

    Zhang Fei; Wang Huanyu; Peng Wenxi; Liang Xiaohua; Zhang Chunlei; Cao Xuelei; Jiang Weichun; Zhang Jiayu; Cui Xingzhu

    2012-01-01

    A high resolution solar soft X-ray spectrometer (SOX) payload onboard a satellite is developed. A silicon drift detector (SDD) is adopted as the detector of the SOX spectrometer. The spectrometer consists of the detectors and their readout electronics, a data acquisition unit and a payload data handling unit. A ground test system is also developed to test SOX. The test results show that the design goals of the spectrometer system have been achieved. (authors)

  3. Volatilities, Traded Volumes, and Price Increments in Derivative Securities

    Science.gov (United States)

    Kim, Kyungsik; Lim, Gyuchang; Kim, Soo Yong; Scalas, Enrico

    2007-03-01

    We apply the detrended fluctuation analysis (DFA) to the statistics of the Korean treasury bond (KTB) futures from which the logarithmic increments, volatilities, and traded volumes are estimated over a specific time lag. For our case, the logarithmic increment of futures prices has no long-memory property, while the volatility and the traded volume exhibit the existence of long-memory property. To analyze and calculate whether the volatility clustering is due to the inherent higher-order correlation not detected by applying directly the DFA to logarithmic increments of the KTB futures, it is of importance to shuffle the original tick data of futures prices and to generate the geometric Brownian random walk with the same mean and standard deviation. It is really shown from comparing the three tick data that the higher-order correlation inherent in logarithmic increments makes the volatility clustering. Particularly, the result of the DFA on volatilities and traded volumes may be supported the hypothesis of price changes.

  4. Space-time quantitative source apportionment of soil heavy metal concentration increments.

    Science.gov (United States)

    Yang, Yong; Christakos, George; Guo, Mingwu; Xiao, Lu; Huang, Wei

    2017-04-01

    Assessing the space-time trends and detecting the sources of heavy metal accumulation in soils have important consequences in the prevention and treatment of soil heavy metal pollution. In this study, we collected soil samples in the eastern part of the Qingshan district, Wuhan city, Hubei Province, China, during the period 2010-2014. The Cd, Cu, Pb and Zn concentrations in soils exhibited a significant accumulation during 2010-2014. The spatiotemporal Kriging technique, based on a quantitative characterization of soil heavy metal concentration variations in terms of non-separable variogram models, was employed to estimate the spatiotemporal soil heavy metal distribution in the study region. Our findings showed that the Cd, Cu, and Zn concentrations have an obvious incremental tendency from the southwestern to the central part of the study region. However, the Pb concentrations exhibited an obvious tendency from the northern part to the central part of the region. Then, spatial overlay analysis was used to obtain absolute and relative concentration increments of adjacent 1- or 5-year periods during 2010-2014. The spatial distribution of soil heavy metal concentration increments showed that the larger increments occurred in the center of the study region. Lastly, the principal component analysis combined with the multiple linear regression method were employed to quantify the source apportionment of the soil heavy metal concentration increments in the region. Our results led to the conclusion that the sources of soil heavy metal concentration increments should be ascribed to industry, agriculture and traffic. In particular, 82.5% of soil heavy metal concentration increment during 2010-2014 was ascribed to industrial/agricultural activities sources. Using STK and SOA to obtain the spatial distribution of heavy metal concentration increments in soils. Using PCA-MLR to quantify the source apportionment of soil heavy metal concentration increments. Copyright © 2017

  5. Crystal-diffraction spectrometer of increased efficiency

    International Nuclear Information System (INIS)

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  6. MEMS based digital transform spectrometers

    Science.gov (United States)

    Geller, Yariv; Ramani, Mouli

    2005-09-01

    Earlier this year, a new breed of Spectrometers based on Micro-Electro-Mechanical-System (MEMS) engines has been introduced to the commercial market. The use of these engines combined with transform mathematics, produces powerful spectrometers at unprecedented low cost in various spectral regions.

  7. Support vector machine incremental learning triggered by wrongly predicted samples

    Science.gov (United States)

    Tang, Ting-long; Guan, Qiu; Wu, Yi-rong

    2018-05-01

    According to the classic Karush-Kuhn-Tucker (KKT) theorem, at every step of incremental support vector machine (SVM) learning, the newly adding sample which violates the KKT conditions will be a new support vector (SV) and migrate the old samples between SV set and non-support vector (NSV) set, and at the same time the learning model should be updated based on the SVs. However, it is not exactly clear at this moment that which of the old samples would change between SVs and NSVs. Additionally, the learning model will be unnecessarily updated, which will not greatly increase its accuracy but decrease the training speed. Therefore, how to choose the new SVs from old sets during the incremental stages and when to process incremental steps will greatly influence the accuracy and efficiency of incremental SVM learning. In this work, a new algorithm is proposed to select candidate SVs and use the wrongly predicted sample to trigger the incremental processing simultaneously. Experimental results show that the proposed algorithm can achieve good performance with high efficiency, high speed and good accuracy.

  8. Average-case analysis of incremental topological ordering

    DEFF Research Database (Denmark)

    Ajwani, Deepak; Friedrich, Tobias

    2010-01-01

    Many applications like pointer analysis and incremental compilation require maintaining a topological ordering of the nodes of a directed acyclic graph (DAG) under dynamic updates. All known algorithms for this problem are either only analyzed for worst-case insertion sequences or only evaluated...... experimentally on random DAGs. We present the first average-case analysis of incremental topological ordering algorithms. We prove an expected runtime of under insertion of the edges of a complete DAG in a random order for the algorithms of Alpern et al. (1990) [4], Katriel and Bodlaender (2006) [18], and Pearce...

  9. Motion-Induced Blindness Using Increments and Decrements of Luminance

    Directory of Open Access Journals (Sweden)

    Stine Wm Wren

    2017-10-01

    Full Text Available Motion-induced blindness describes the disappearance of stationary elements of a scene when other, perhaps non-overlapping, elements of the scene are in motion. We measured the effects of increment (200.0 cd/m2 and decrement targets (15.0 cd/m2 and masks presented on a grey background (108.0 cd/m2, tapping into putative ON- and OFF-channels, on the rate of target disappearance psychophysically. We presented two-frame motion, which has coherent motion energy, and dynamic Glass patterns and dynamic anti-Glass patterns, which do not have coherent motion energy. Using the method of constant stimuli, participants viewed stimuli of varying durations (3.1 s, 4.6 s, 7.0 s, 11 s, or 16 s in a given trial and then indicated whether or not the targets vanished during that trial. Psychometric function midpoints were used to define absolute threshold mask duration for the disappearance of the target. 95% confidence intervals for threshold disappearance times were estimated using a bootstrap technique for each of the participants across two experiments. Decrement masks were more effective than increment masks with increment targets. Increment targets were easier to mask than decrement targets. Distinct mask pattern types had no effect, suggesting that perceived coherence contributes to the effectiveness of the mask. The ON/OFF dichotomy clearly carries its influence to the level of perceived motion coherence. Further, the asymmetry in the effects of increment and decrement masks on increment and decrement targets might lead one to speculate that they reflect the ‘importance’ of detecting decrements in the environment.

  10. Electro-Optical Imaging Fourier-Transform Spectrometer

    Science.gov (United States)

    Chao, Tien-Hsin; Zhou, Hanying

    2006-01-01

    An electro-optical (E-O) imaging Fourier-transform spectrometer (IFTS), now under development, is a prototype of improved imaging spectrometers to be used for hyperspectral imaging, especially in the infrared spectral region. Unlike both imaging and non-imaging traditional Fourier-transform spectrometers, the E-O IFTS does not contain any moving parts. Elimination of the moving parts and the associated actuator mechanisms and supporting structures would increase reliability while enabling reductions in size and mass, relative to traditional Fourier-transform spectrometers that offer equivalent capabilities. Elimination of moving parts would also eliminate the vibrations caused by the motions of those parts. Figure 1 schematically depicts a traditional Fourier-transform spectrometer, wherein a critical time delay is varied by translating one the mirrors of a Michelson interferometer. The time-dependent optical output is a periodic representation of the input spectrum. Data characterizing the input spectrum are generated through fast-Fourier-transform (FFT) post-processing of the output in conjunction with the varying time delay.

  11. Logistics Modernization Program Increment 2 (LMP Inc 2)

    Science.gov (United States)

    2016-03-01

    Sections 3 and 4 of the LMP Increment 2 Business Case, ADM), key functional requirements, Critical Design Review (CDR) Reports, and Economic ...from the 2013 version of the LMP Increment 2 Economic Analysis and replace it with references to the Economic Analysis that will be completed...of ( inbound /outbound) IDOCs into the system. LMP must be able to successfully process 95% of ( inbound /outbound) IDOCs into the system. Will meet

  12. Incremental Tensor Principal Component Analysis for Handwritten Digit Recognition

    Directory of Open Access Journals (Sweden)

    Chang Liu

    2014-01-01

    Full Text Available To overcome the shortcomings of traditional dimensionality reduction algorithms, incremental tensor principal component analysis (ITPCA based on updated-SVD technique algorithm is proposed in this paper. This paper proves the relationship between PCA, 2DPCA, MPCA, and the graph embedding framework theoretically and derives the incremental learning procedure to add single sample and multiple samples in detail. The experiments on handwritten digit recognition have demonstrated that ITPCA has achieved better recognition performance than that of vector-based principal component analysis (PCA, incremental principal component analysis (IPCA, and multilinear principal component analysis (MPCA algorithms. At the same time, ITPCA also has lower time and space complexity.

  13. Il caso della Mobile-Health: l’autogestione della salute tra autonomia ed eteronomia

    Directory of Open Access Journals (Sweden)

    MEOLA, LORELLA

    2016-06-01

    Full Text Available The Case Of Mobile-Health: health Self‐Management between Autonomy and Eteronomy This paper analyses the change in medical practice and, in wider terms, in health-care system, due to the use of mobile health. It helps create patient’s autonomy because it provides technological tools to develop self-care in every moment of life; but, in this way, it encroaches the patient’s life, producing a strong medical addiction. In biopolitics background, in particular connection with Michel Foucault, this paper shows how the use of mobile communication devices in health care could produce an increment of medicalization of life. Furthermore, perpetual attendance of medicine in the patient’s life generates a new relevance of health, becoming increasingly blurred wellness’s ideal.

  14. Charged particle scintillation mass spectrometer

    International Nuclear Information System (INIS)

    Baranov, P.S.; Zhuravlev, E.E.; Nafikov, A.A.; Osadchi , A.I.; Raevskij, V.G.; Smirnov, P.A.; Cherepnya, S.N.; Yanulis, Yu.P.

    1982-01-01

    A scintillation mass-spectrometer for charged particle identification by the measured values of time-of-flight and energy operating on line with the D-116 computer is described. Original time detectors with 100x100x2 mm 3 and 200x2 mm 2 scintillators located on the 1- or 2 m path length are used in the spectrometer. The 200x200x200 mm 3 scintillation unit is used as a E-counter. Time-of-flight spectra of the detected particles on the 2 m path length obtained in spectrometer test in the beam of charged particles escaping from the carbon target at the angle of 130 deg under 1.2 GeV bremsstrahlung beam of the ''Pakhra'' PIAS synchrotron are presented. Proton and deuteron energy spectra as well as mass spectrum of all the particles detected by the spectrometer are given. Mass resolution obtained on the 2 m path length for π-mesons is +-25%, for protons is +-5%, for deuterons is +-3%

  15. Deprotonation effect of tetrahydrofuran-2-carbonitrile buffer gas dopant in ion mobility spectrometry.

    Science.gov (United States)

    Fernandez-Maestre, Roberto; Meza-Morelos, Dairo; Wu, Ching

    2016-06-15

    When dopants are introduced into the buffer gas of an ion mobility spectrometer, spectra are simplified due to charge competition. We used electrospray ionization to inject tetrahydrofuran-2-carbonitrile (F, 2-furonitrile or 2-furancarbonitrile) as a buffer gas dopant into an ion mobility spectrometer coupled to a quadrupole mass spectrometer. Density functional theory was used for theoretical calculations of dopant-ion interaction energies and proton affinities, using the hybrid functional X3LYP/6-311++(d,p) with the Gaussian 09 program that accounts for the basis set superposition error; analytes structures and theoretical calculations with Gaussian were used to explain the behavior of the analytes upon interaction with F. When F was used as a dopant at concentrations below 1.5 mmol m(-3) in the buffer gas, ions were not observed for α-amino acids due to charge competition with the dopant; this deprotonation capability arises from the production of a dimer with a high formation energy that stabilized the positive charge and created steric hindrance that deterred the equilibrium with analyte ions. F could not completely strip other compounds of their charge because they either showed steric hindrance at the charge site that deterred the approach of the dopant (2,4-lutidine, and DTBP), formed intramolecular bonds that stabilized the positive charge (atenolol), had high proton affinity (2,4-lutidine, DTBP, valinol and atenolol), or were inherently ionic (tetraalkylammonium ions). This selective deprotonation suggests the use of F to simplify spectra of complex mixtures in ion mobility and mass spectrometry in metabolomics, proteomics and other studies that generate complex spectra with thousands of peaks. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Validation of the periodicity of growth increment deposition in ...

    African Journals Online (AJOL)

    Validation of the periodicity of growth increment deposition in otoliths from the larval and early juvenile stages of two cyprinids from the Orange–Vaal river ... Linear regression models were fitted to the known age post-fertilisation and the age estimated using increment counts to test the correspondence between the two for ...

  17. Creating Helical Tool Paths for Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Skjødt, Martin; Hancock, Michael H.; Bay, Niels

    2007-01-01

    Single point incremental forming (SPIF) is a relatively new sheet forming process. A sheet is clamped in a rig and formed incrementally using a rotating single point tool in the form of a rod with a spherical end. The process is often performed on a CNC milling machine and the tool movement...

  18. Single point incremental forming: Formability of PC sheets

    Science.gov (United States)

    Formisano, A.; Boccarusso, L.; Carrino, L.; Lambiase, F.; Minutolo, F. Memola Capece

    2018-05-01

    Recent research on Single Point Incremental Forming of polymers has slightly covered the possibility of expanding the materials capability window of this flexible forming process beyond metals, by demonstrating the workability of thermoplastic polymers at room temperature. Given the different behaviour of polymers compared to metals, different aspects need to be deepened to better understand the behaviour of these materials when incrementally formed. Thus, the aim of the work is to investigate the formability of incrementally formed polycarbonate thin sheets. To this end, an experimental investigation at room temperature was conducted involving formability tests; varying wall angle cone and pyramid frusta were manufactured by processing polycarbonate sheets with different thicknesses and using tools with different diameters, in order to draw conclusions on the formability of polymer sheets through the evaluation of the forming angles and the observation of the failure mechanisms.

  19. Martingales, nonstationary increments, and the efficient market hypothesis

    Science.gov (United States)

    McCauley, Joseph L.; Bassler, Kevin E.; Gunaratne, Gemunu H.

    2008-06-01

    We discuss the deep connection between nonstationary increments, martingales, and the efficient market hypothesis for stochastic processes x(t) with arbitrary diffusion coefficients D(x,t). We explain why a test for a martingale is generally a test for uncorrelated increments. We explain why martingales look Markovian at the level of both simple averages and 2-point correlations. But while a Markovian market has no memory to exploit and cannot be beaten systematically, a martingale admits memory that might be exploitable in higher order correlations. We also use the analysis of this paper to correct a misstatement of the ‘fair game’ condition in terms of serial correlations in Fama’s paper on the EMH. We emphasize that the use of the log increment as a variable in data analysis generates spurious fat tails and spurious Hurst exponents.

  20. Digital Spectrometers for Interplanetary Science Missions

    Science.gov (United States)

    Jarnot, Robert F.; Padmanabhan, Sharmila; Raffanti, Richard; Richards, Brian; Stek, Paul; Werthimer, Dan; Nikolic, Borivoje

    2010-01-01

    A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

  1. On the instability increments of a stationary pinch

    International Nuclear Information System (INIS)

    Bud'ko, A.B.

    1989-01-01

    The stability of stationary pinch to helical modes is numerically studied. It is shown that in the case of a rather fast plasma pressure decrease to the pinch boundary, for example, for an isothermal diffusion pinch with Gauss density distribution instabilities with m=0 modes are the most quickly growing. Instability increments are calculated. A simple analytical expression of a maximum increment of growth of sausage instability for automodel Gauss profiles is obtained

  2. Incremental Trust in Grid Computing

    DEFF Research Database (Denmark)

    Brinkløv, Michael Hvalsøe; Sharp, Robin

    2007-01-01

    This paper describes a comparative simulation study of some incremental trust and reputation algorithms for handling behavioural trust in large distributed systems. Two types of reputation algorithm (based on discrete and Bayesian evaluation of ratings) and two ways of combining direct trust and ...... of Grid computing systems....

  3. Convergent systems vs. incremental stability

    NARCIS (Netherlands)

    Rüffer, B.S.; Wouw, van de N.; Mueller, M.

    2013-01-01

    Two similar stability notions are considered; one is the long established notion of convergent systems, the other is the younger notion of incremental stability. Both notions require that any two solutions of a system converge to each other. Yet these stability concepts are different, in the sense

  4. Overtone Mobility Spectrometry: Part 4. OMS-OMS Analyses of Complex Mixtures

    Science.gov (United States)

    Kurulugama, Ruwan T.; Nachtigall, Fabiane M.; Valentine, Stephen J.; Clemmer, David E.

    2011-11-01

    A new, two-dimensional overtone mobility spectrometry (OMS-OMS) instrument is described for the analysis of complex peptide mixtures. OMS separations are based on the differences in mobilities of ions in the gas phase. The method utilizes multiple drift regions with modulated drift fields such that only ions with appropriate mobilities are transmitted to the detector. Here we describe a hybrid OMS-OMS combination that utilizes two independently operated OMS regions that are separated by an ion activation region. Mobility-selected ions from the first OMS region are exposed to energizing collisions and may undergo structural transitions before entering the second OMS region. This method generates additional peak capacity and allows for higher selectivity compared with the one-dimensional OMS method. We demonstrate the approach using a three-protein tryptic digest spiked with the peptide Substance P. The [M + 3H]3+ ion from Substance P can be completely isolated from other components in this complex mixture prior to introduction into the mass spectrometer.

  5. Power calculation of linear and angular incremental encoders

    Science.gov (United States)

    Prokofev, Aleksandr V.; Timofeev, Aleksandr N.; Mednikov, Sergey V.; Sycheva, Elena A.

    2016-04-01

    Automation technology is constantly expanding its role in improving the efficiency of manufacturing and testing processes in all branches of industry. More than ever before, the mechanical movements of linear slides, rotary tables, robot arms, actuators, etc. are numerically controlled. Linear and angular incremental photoelectric encoders measure mechanical motion and transmit the measured values back to the control unit. The capabilities of these systems are undergoing continual development in terms of their resolution, accuracy and reliability, their measuring ranges, and maximum speeds. This article discusses the method of power calculation of linear and angular incremental photoelectric encoders, to find the optimum parameters for its components, such as light emitters, photo-detectors, linear and angular scales, optical components etc. It analyzes methods and devices that permit high resolutions in the order of 0.001 mm or 0.001°, as well as large measuring lengths of over 100 mm. In linear and angular incremental photoelectric encoders optical beam is usually formulated by a condenser lens passes through the measuring unit changes its value depending on the movement of a scanning head or measuring raster. Past light beam is converting into an electrical signal by the photo-detecter's block for processing in the electrical block. Therefore, for calculating the energy source is a value of the desired value of the optical signal at the input of the photo-detecter's block, which reliably recorded and processed in the electronic unit of linear and angular incremental optoelectronic encoders. Automation technology is constantly expanding its role in improving the efficiency of manufacturing and testing processes in all branches of industry. More than ever before, the mechanical movements of linear slides, rotary tables, robot arms, actuators, etc. are numerically controlled. Linear and angular incremental photoelectric encoders measure mechanical motion and

  6. Making context explicit for explanation and incremental knowledge acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Brezillon, P. [Univ. Paris (France)

    1996-12-31

    Intelligent systems may be improved by making context explicit in problem solving. This is a lesson drawn from a study of the reasons why a number of knowledge-based systems (KBSs) failed. We discuss the interest to make context explicit in explanation generation and incremental knowledge acquisition, two important aspects of intelligent systems that aim to cooperate with users. We show how context can be used to better explain and incrementally acquire knowledge. The advantages of using context in explanation and incremental knowledge acquisition are discussed through SEPIT, an expert system for supporting diagnosis and explanation through simulation of power plants. We point out how the limitations of such systems may be overcome by making context explicit.

  7. Combined raman spectrometer/laser-induced breakdown spectrometer design concept

    Science.gov (United States)

    Bazalgette Courrèges-Lacoste, Gregory; Ahlers, Berit; Boslooper, Erik; Rull-Perez, Fernando; Maurice, Sylvestre

    2017-11-01

    Amongst the different instruments that have been preselected to be on-board the Pasteur payload on ExoMars is the Raman/ Laser Induced Breakdown Spectroscopy (LIBS) instrument. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities. An international team under the lead of TNO has been gathered to produce a design concept for a combined Raman Spectrometer/ LIBS Elegant Bread-Board (EBB). The instrument is based on a specifically designed extremely compact spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. Low mass, size and resources are the main drivers of the instrument's design concept. The proposed design concept, realization and testing programme for the combined Raman/ LIBS EBB is presented as well as background information on Raman and LIBS.

  8. Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

    International Nuclear Information System (INIS)

    Keck, L; Pesch, M; Grimm, H

    2011-01-01

    A wide range aerosol spectrometer (WRAS) was used for comprehensive long term measurements of aerosol size distributions. The system combines the results of an optical aerosol spectrometer with the results of a Scanning Mobility Particle Sizer (SMPS) to record essentially the full size range (5 nm - 32 μm) of atmospheric particles in 72 channels. Measurements were carried out over one year (2009) at the Global Atmospheric Watch (GAW)-Station Hohenpeissenberg, Bavaria. Total particle number concentrations obtained from the aerosol size distributions were compared to the total number concentrations measured by a Condensation Particle Counter (CPC). The comparison showed an excellent agreement of the data. The high time resolution of 5 minutes allows the combination of the measured size distributions with meteorological data and correlations to gaseous pollutants (CO, NOx and SO2). A good correlation of particle number and CO concentrations was found for long distance transported small particles, which were probably mainly soot particles. Correlations to NOx were observed for aerosols from local sources such as traffic emissions. The formation of secondary aerosols from gaseous precursors was also observed. Episodes of relatively high concentration of particles in the range of 2-3 μm were probably caused by pollen.

  9. Wireless, low-cost, FPGA-based miniature gamma ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Becker, E.M., E-mail: beckere@engr.orst.edu; Farsoni, A.T.

    2014-10-11

    A compact, low-cost, wireless gamma-ray spectrometer is a tool sought by a number of different organizations in the field of radiation detection. Such a device has applications in emergency response, battlefield assessment, and personal dosimetry. A prototype device fitting this description has been constructed in the Advanced Radiation Instrumentation Laboratory at Oregon State University. The prototype uses a CsI(Tl) scintillator coupled to a solid-state photomultiplier and a 40 MHz, 12-bit, FPGA-based digital pulse processor to measure gamma radiation, and is able to be accessed wirelessly by mobile phone. The prototype device consumes roughly 420 mW, weighs about 28 g (not including battery), and measures 2.54×3.81 cm{sup 2}. The prototype device is able to achieve 5.9% FWHM energy resolution at 662 keV.

  10. Development of mobile radiological assessment laboratory

    International Nuclear Information System (INIS)

    Pujari, R.N.; Saindane, Shashank S.; Jain, Amit; Parmar, Jayesh; Narsaiah, M.V.R.; Pote, M.B.; Murali, S.; Chaudhury, Probal

    2018-01-01

    During any emergency situations real-time radiation measurements and the fast analysis of the measured radiological data are of crucial importance. The newly developed mobile vehicle based laboratory known as 'Radiological Assessment Laboratory' (RAL) can be used for real time measurements in different radiation emergency scenarios, such as the release of radioactive materials from a radiological/nuclear incident, during search of an orphan source or during radioisotope transportation. RAL is equipped with several high sensitive detectors/systems such as NaI(Tl) gamma spectrometers, large size plastic scintillators and air-sampler, along with GPS and data transfer capability through GSM modem

  11. Recent ion optics and mass spectrometers

    International Nuclear Information System (INIS)

    Matsuda, Hisashi

    1976-01-01

    The establishment of the third order approximation method for computing the orbit of the ion optical system for mass spectrometers and the completion of its computer program are reported. A feature of this orbit computation is in that the effect of the fringing field can be considered with the accuracy of third order approximation. Several new ion optical systems for mass spectrometers have been proposed by using such orbit computing programs. Brief explanation and the description on the future prospect and problems are made on the following items: the vertual image double focusing mass spectrometer, the second order double focusing mass spectrometer, the E x B superposed field mass spectrometer, and the apparatus with a cylindrical electric field and Q-lens. In the E x B superposed field with Matsuda plates, if the magnetic field is generated by an electromagnet instead of a permanent magnet, the dispersion of mass and energy can be changed at will. The Matsuda plates are known as the auxiliary electrodes positioned at the top and bottom of a cylindrical capacitor. Utilizing those characteristics, a zoom spectrometer can be made, with which only a necessary part of mass spectra can be investigated in detail, but the whole spectra are investigated roughly. In addition, the distribution of energy can be investigated simultaneously after the separation of ionic mass similarly to the parabola apparatus. (Iwakiri, K.)

  12. Three routes forward for biofuels: Incremental, leapfrog, and transitional

    International Nuclear Information System (INIS)

    Morrison, Geoff M.; Witcover, Julie; Parker, Nathan C.; Fulton, Lew

    2016-01-01

    This paper examines three technology routes for lowering the carbon intensity of biofuels: (1) a leapfrog route that focuses on major technological breakthroughs in lignocellulosic pathways at new, stand-alone biorefineries; (2) an incremental route in which improvements are made to existing U.S. corn ethanol and soybean biodiesel biorefineries; and (3) a transitional route in which biotechnology firms gain experience growing, handling, or chemically converting lignocellulosic biomass in a lower-risk fashion than leapfrog biorefineries by leveraging existing capital stock. We find the incremental route is likely to involve the largest production volumes and greenhouse gas benefits until at least the mid-2020s, but transitional and leapfrog biofuels together have far greater long-term potential. We estimate that the Renewable Fuel Standard, California's Low Carbon Fuel Standard, and federal tax credits provided an incentive of roughly $1.5–2.5 per gallon of leapfrog biofuel between 2012 and 2015, but that regulatory elements in these policies mostly incentivize lower-risk incremental investments. Adjustments in policy may be necessary to bring a greater focus on transitional technologies that provide targeted learning and cost reduction opportunities for leapfrog biofuels. - Highlights: • Three technological pathways are compared that lower carbon intensity of biofuels. • Incremental changes lead to faster greenhouse gas reductions. • Leapfrog changes lead to greatest long-term potential. • Two main biofuel policies (RFS and LCFS) are largely incremental in nature. • Transitional biofuels offer medium-risk, medium reward pathway.

  13. The TRIUMF low energy pion spectrometer and channel

    International Nuclear Information System (INIS)

    Sobie, R.J.; Drake, T.E.; Barnett, B.M.; Erdman, K.L.; Gyles, W.; Johnson, R.R.; Roser, H.W.; Tacik, R.; Blackmore, E.W.; Gill, D.R.

    1983-08-01

    A low energy pion spectrometer has been developed for use with the TRIUMF M13 pion channel. The combined channel and spectrometer resolution is presently 1.1 MeV at T = 50 MeV. This is limited by the amount of gas and detector material in the spectrometer in addition to the inherent resolution of the channel. Improvements to both the spectrometer and channel are discussed

  14. Electron volt neutron spectrometers

    International Nuclear Information System (INIS)

    Pietropaolo, A.; Senesi, R.

    2011-01-01

    The advent of pulsed neutron sources has made available intense fluxes of epithermal neutrons (500 meV ≤E≤100 eV ). The possibility to open new investigations on condensed matter with eV neutron scattering techniques, is related to the development of methods, concepts and devices that drive, or are inspired by, emerging studies at this energy scale. Electron volt spectrometers have undergone continuous improvements since the construction of the first prototype instruments, but in the last decade major breakthroughs have been accomplished in terms of resolution and counting statistics, leading, for example, to the direct measurement of the proton 3-D Born–Oppenheimer potential in any material, or to quantitatively probe nuclear quantum effects in hydrogen bonded systems. This paper reports on the most effective methods and concepts for energy analysis and detection, as well as devices for the optimization of electron volt spectrometers for different applications. This is set in the context of the progress made up to date in instrument development. Starting from early stages of development of the technique, particular emphasis will be given to the Vesuvio eV spectrometer at the ISIS neutron source, the first spectrometer where extensive scientific, as well as research and development programmes have been carried out. The potential offered by this type of instrumentation, from single particle excitations to momentum distribution studies, is then put in perspective into the emerging fields of eV spectroscopy applied to cultural heritages and neutron irradiation effects in electronics. - Highlights: ► Neutron spectrometers at eV energies. ► Methods and techniques for eV neutrons counting at spallation sources. ► Scattering, imaging and radiation hardness tests with multi-eV neutrons.

  15. Engineering the mobility increment in pentacene-based field-effect transistors by fast cooling of polymeric modification layer

    Science.gov (United States)

    Ling, Haifeng; Zhang, Chenxi; Chen, Yan; Shao, Yaqing; Li, Wen; Li, Huanqun; Chen, Xudong; Yi, Mingdong; Xie, Linghai; Huang, Wei

    2017-06-01

    In this work, we investigate the effect of the cooling rate of polymeric modification layers (PMLs) on the mobility improvement of pentacene-based organic field-effect transistors (OFETs). In contrast to slow cooling (SC), the OFETs fabricated through fast cooling (FC) with PMLs containing side chain-phenyl rings, such as polystyrene (PS) and poly (4-vinylphenol) (PVP), show an obvious mobility incensement compared with that of π-group free polymethylmethacrylate (PMMA). Atomic force microscopy (AFM) images and x-ray diffraction (XRD) characterizations have showed that fast-cooled PMLs could effectively enhance the crystallinity of pentacene, which might be related to the optimized homogeneity of surface energy on the surface of polymeric dielectrics. Our work has demonstrated that FC treatment could be a potential strategy for performance modulation of OFETs.

  16. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  17. Ultra-Wideband Optical Modulation Spectrometer (OMS) Development

    Science.gov (United States)

    Gardner, Jonathan (Technical Monitor); Tolls, Volker

    2004-01-01

    The optical modulation spectrometer (OMS) is a novel, highly efficient, low mass backend for heterodyne receiver systems. Current and future heterodyne receiver systems operating at frequencies up to a few THz require broadband spectrometer backends to achieve spectral resolutions of R approximately 10(exp 5) to 10(exp 6) to carry out many important astronomical investigations. Among these are observations of broad emission and absorption lines from extra-galactic objects at high redshifts, spectral line surveys, and observations of planetary atmospheres. Many of these lines are pressure or velocity broadened with either large half-widths or line wings extending over several GHz. Current backend systems can cover the needed bandwidth only by combining the output of several spectrometers, each with typically up to 1 GHz bandwidth, or by combining several frequency-shifted spectra taken with a single spectrometer. An ultra-wideband optical modulation spectrometer with 10 - 40 GHz bandwidth will enable broadband ob- servations without the limitations and disadvantages of hybrid spectrometers. Spectrometers like the OMS will be important for both ground-based observatories and future space missions like the Single Aperture Far-Infrared Telescope (SAFIR) which might carry IR/submm array heterodyne receiver systems requiring a spectrometer for each array pixel. Small size, low mass and small power consumption are extremely important for space missions. This report summarizes the specifications developed for the OMS and lists already identified commercial parts. The report starts with a review of the principle of operation, then describes the most important components and their specifications which were derived from theory, and finishes with a conclusion and outlook.

  18. Incrementality in naming and reading complex numerals: Evidence from eyetracking

    NARCIS (Netherlands)

    Korvorst, M.H.W.; Roelofs, A.P.A.; Levelt, W.J.M.

    2006-01-01

    Individuals speak incrementally when they interleave planning and articulation. Eyetracking, along with the measurement of speech onset latencies, can be used to gain more insight into the degree of incrementality adopted by speakers. In the current article, two eyetracking experiments are reported

  19. Mid infrared MEMS FTIR spectrometer

    Science.gov (United States)

    Erfan, Mazen; Sabry, Yasser M.; Mortada, Bassem; Sharaf, Khaled; Khalil, Diaa

    2016-03-01

    In this work we report, for the first time to the best of our knowledge, a bulk-micromachined wideband MEMS-based spectrometer covering both the NIR and the MIR ranges and working from 1200 nm to 4800 nm. The core engine of the spectrometer is a scanning Michelson interferometer micro-fabricated using deep reactive ion etching (DRIE) technology. The spectrum is obtained using the Fourier Transform techniques that allows covering a very wide spectral range limited by the detector responsivity. The moving mirror of the interferometer is driven by a relatively large stroke electrostatic comb-drive actuator. Zirconium fluoride (ZrF4) multimode optical fibers are used to connect light between the white light source and the interferometer input, as well as the interferometer output to a PbSe photoconductive detector. The recorded signal-to-noise ratio is 25 dB at the wavelength of 3350 nm. The spectrometer is successfully used in measuring the absorption spectra of methylene chloride, quartz glass and polystyrene film. The presented solution provides a low cost method for producing miniaturized spectrometers in the near-/mid-infrared.

  20. User-Adapted Recommendation of Content on Mobile Devices Using Bayesian Networks

    Science.gov (United States)

    Iwasaki, Hirotoshi; Mizuno, Nobuhiro; Hara, Kousuke; Motomura, Yoichi

    Mobile devices, such as cellular phones and car navigation systems, are essential to daily life. People acquire necessary information and preferred content over communication networks anywhere, anytime. However, usability issues arise from the simplicity of user interfaces themselves. Thus, a recommendation of content that is adapted to a user's preference and situation will help the user select content. In this paper, we describe a method to realize such a system using Bayesian networks. This user-adapted mobile system is based on a user model that provides recommendation of content (i.e., restaurants, shops, and music that are suitable to the user and situation) and that learns incrementally based on accumulated usage history data. However, sufficient samples are not always guaranteed, since a user model would require combined dependency among users, situations, and contents. Therefore, we propose the LK method for modeling, which complements incomplete and insufficient samples using knowledge data, and CPT incremental learning for adaptation based on a small number of samples. In order to evaluate the methods proposed, we applied them to restaurant recommendations made on car navigation systems. The evaluation results confirmed that our model based on the LK method can be expected to provide better generalization performance than that of the conventional method. Furthermore, our system would require much less operation than current car navigation systems from the beginning of use. Our evaluation results also indicate that learning a user's individual preference through CPT incremental learning would be beneficial to many users, even with only a few samples. As a result, we have developed the technology of a system that becomes more adapted to a user the more it is used.

  1. Gas-dust-impact mass spectrometer

    CERN Document Server

    Semkin, N D; Myasnikov, S V; Pomelnikov, R A

    2002-01-01

    Paper describes design of a mass spectrometer to study element composition of micro meteorite and man-made particles in space. Paper describes a way to improve resolution of mass spectrometer based on variation of parameters of accelerating electric field in time. The advantage of the given design of mass spectrometer in comparison with similar ones is its large operating area and higher resolution at the comparable weight and dimensions. Application of a combined design both for particles and for gas enables to remove space vehicle degassing products from the spectrum and, thus, to improve reliability of the acquired information, as well as, to acquire information on a gas component of the external atmosphere of a space vehicle

  2. An ARM Mobile Facility Designed for Marine Deployments

    Science.gov (United States)

    Wiscombe, W. J.

    2007-05-01

    The U.S. Dept. of Energy's ARM (Atmospheric Radiation Measurements) Program is designing a Mobile Facility exclusively for marine deployments. This marine facility is patterned after ARM's land Mobile Facility, which had its inaugural deployment at Point Reyes, California, in 2005, followed by deployments to Niger in 2006 and Germany in 2007 (ongoing), and a planned deployment to China in 2008. These facilities are primarily intended for the study of clouds, radiation, aerosols, and surface processes with a goal to include these processes accurately in climate models. They are preferably embedded within larger field campaigns which provide context. They carry extensive instrumentation (in several large containers) including: cloud radar, lidar, microwave radiometers, infrared spectrometers, broadband and narrowband radiometers, sonde-launching facilities, extensive surface aerosol measurements, sky imagers, and surface latent and sensible heat flux devices. ARM's Mobile Facilities are designed for 6-10 month deployments in order to capture climatically-relevant datasets. They are available to any scientist, U.S. or international, who wishes to submit a proposal during the annual Spring call. The marine facility will be adapted to, and ruggedized for, the harsh marine environment and will add a scanning two-frequency radar, a boundary-layer wind profiler, a shortwave spectrometer, and aerosol instrumentation adapted to typical marine aerosols like sea salt. Plans also include the use of roving small UAVs, automated small boats, and undersea autonomous vehicles in order to address the point-to-area-average problem which is so crucial for informing climate models. Initial deployments are planned for small islands in climatically- interesting cloud regimes, followed by deployments on oceanic platforms (like decommissioned oil rigs and the quasi-permanent platform of this session's title) and eventually on large ships like car carriers plying routine routes.

  3. Finance for incremental housing: current status and prospects for expansion

    NARCIS (Netherlands)

    Ferguson, B.; Smets, P.G.S.M.

    2010-01-01

    Appropriate finance can greatly increase the speed and lower the cost of incremental housing - the process used by much of the low/moderate-income majority of most developing countries to acquire shelter. Informal finance continues to dominate the funding of incremental housing. However, new sources

  4. One Step at a Time: SBM as an Incremental Process.

    Science.gov (United States)

    Conrad, Mark

    1995-01-01

    Discusses incremental SBM budgeting and answers questions regarding resource equity, bookkeeping requirements, accountability, decision-making processes, and purchasing. Approaching site-based management as an incremental process recognizes that every school system engages in some level of site-based decisions. Implementation can be gradual and…

  5. Detection of nitro-based and peroxide-based explosives by fast polarity-switchable ion mobility spectrometer with ion focusing in vicinity of Faraday detector.

    Science.gov (United States)

    Zhou, Qinghua; Peng, Liying; Jiang, Dandan; Wang, Xin; Wang, Haiyan; Li, Haiyang

    2015-05-29

    Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was constructed to detect these two explosive species in a single measurement. As the large traditional Faraday detector would cause a trailing reactant ion peak (RIP), a Faraday detector with ion focusing in vicinity was developed by reducing the detector radius to 3.3 mm and increasing the voltage difference between aperture grid and its front guard ring to 591 V, which could remove trailing peaks from RIP without loss of signal intensity. This fast polarity-switchable IMS with ion focusing in vicinity of Faraday detector was employed to detect a mixture of 10 ng 2,4,6-trinitrotoluene (TNT) and 50 ng hexamethylene triperoxide diamine (HMTD) by polarity-switching, and the result suggested that [TNT-H](-) and [HMTD+H](+) could be detected in a single measurement. Furthermore, the removal of trailing peaks from RIP by the Faraday detector with ion focusing in vicinity also promised the accurate identification of KClO4, KNO3 and S in common inorganic explosives, whose product ion peaks were fairly adjacent to RIP.

  6. History Matters: Incremental Ontology Reasoning Using Modules

    Science.gov (United States)

    Cuenca Grau, Bernardo; Halaschek-Wiener, Christian; Kazakov, Yevgeny

    The development of ontologies involves continuous but relatively small modifications. Existing ontology reasoners, however, do not take advantage of the similarities between different versions of an ontology. In this paper, we propose a technique for incremental reasoning—that is, reasoning that reuses information obtained from previous versions of an ontology—based on the notion of a module. Our technique does not depend on a particular reasoning calculus and thus can be used in combination with any reasoner. We have applied our results to incremental classification of OWL DL ontologies and found significant improvement over regular classification time on a set of real-world ontologies.

  7. Study of neutron spectrometers for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Kaellne, Jan

    2005-11-15

    A review is presented of the developments in the field of neutron emission spectrometry (NES) which is of relevance for identifying the role of NES diagnostics on ITER and selecting suitable instrumentation. Neutron spectrometers will be part of the ITER neutron diagnostic complement and this study makes a special effort to examine which performance characteristics the spectrometers should possess to provide the best burning plasma diagnostic information together with neutron cameras and neutron yield monitors. The performance of NES diagnostics is coupled to how much interface space can be provided which has lead to an interest to find compact instruments and their NES capabilities. This study assesses all known spectrometer types of potential interest for ITER and makes a ranking of their performance (as demonstrated or projected), which, in turn, are compared with ITER measurement requirements as a reference; the ratio of diagnostic performance to interface cost for different spectrometers is also discussed for different spectrometer types. The overall result of the study is an assessment of which diagnostic functions neutron measurements can provide in burning plasma fusion experiments on ITER and the role that NES can play depending on the category of instrument installed. Of special note is the result that much higher quality diagnostic information can be obtained from neutron measurements with total yield monitors, profile flux cameras and spectrometers when the synergy in the data is considered in the analysis and interpretation.

  8. 76 FR 73475 - Immigration Benefits Business Transformation, Increment I; Correction

    Science.gov (United States)

    2011-11-29

    ... Benefits Business Transformation, Increment I, 76 FR 53764 (Aug. 29, 2011). The final rule removed form... [CIS No. 2481-09; Docket No. USCIS-2009-0022] RIN 1615-AB83 Immigration Benefits Business Transformation, Increment I; Correction AGENCY: U.S. Citizenship and Immigration Services, DHS. ACTION: Final...

  9. Multi-spectrometer calibration transfer based on independent component analysis.

    Science.gov (United States)

    Liu, Yan; Xu, Hao; Xia, Zhenzhen; Gong, Zhiyong

    2018-02-26

    Calibration transfer is indispensable for practical applications of near infrared (NIR) spectroscopy due to the need for precise and consistent measurements across different spectrometers. In this work, a method for multi-spectrometer calibration transfer is described based on independent component analysis (ICA). A spectral matrix is first obtained by aligning the spectra measured on different spectrometers. Then, by using independent component analysis, the aligned spectral matrix is decomposed into the mixing matrix and the independent components of different spectrometers. These differing measurements between spectrometers can then be standardized by correcting the coefficients within the independent components. Two NIR datasets of corn and edible oil samples measured with three and four spectrometers, respectively, were used to test the reliability of this method. The results of both datasets reveal that spectra measurements across different spectrometers can be transferred simultaneously and that the partial least squares (PLS) models built with the measurements on one spectrometer can predict that the spectra can be transferred correctly on another.

  10. [Design of Dual-Beam Spectrometer in Spectrophotometer for Colorimetry].

    Science.gov (United States)

    Liu, Yi-xuan; Yan, Chang-xiang

    2015-07-01

    Spectrophotometers for colorimetry are usually composed of two independent and identical spectrometers. In order to reduce the volume of spectrophotometer for colorimetry, a design method of double-beam spectrometer is put forward. A traditional spectrometer is modified so that a new spectrometer can realize the function of double spectrometers, which is especially suitable for portable instruments. One slit is replaced by the double-slit, than two beams of spectrum can be detected. The working principle and design requirement of double-beam spectrometer are described. A spectrometer of portable spectrophotometer is designed by this method. A toroidal imaging mirror is used for the Czerny-Turner double-beam spectrometer in this paper, which can better correct astigmatism, and prevent the dual-beam spectral crosstalk. The results demonstrate that the double-beam spectrometer designed by this method meets the design specifications, with the spectral resolution less than 10 nm, the spectral length of 9.12 mm, and the volume of 57 mm x 54 mm x 23 mm, and without the dual-beam spectral overlap in the detector either. Comparing with a traditional spectrophotometer, the modified spectrophotometer uses a set of double-beam spectrometer instead of two sets of spectrometers, which can greatly reduce the volume. This design method can be specially applied in portable spectrophotometers, also can be widely applied in other double-beam spectrophotometers, which offers a new idea for the design of dual-beam spectrophotometers.

  11. Short-term load forecasting with increment regression tree

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jingfei; Stenzel, Juergen [Darmstadt University of Techonology, Darmstadt 64283 (Germany)

    2006-06-15

    This paper presents a new regression tree method for short-term load forecasting. Both increment and non-increment tree are built according to the historical data to provide the data space partition and input variable selection. Support vector machine is employed to the samples of regression tree nodes for further fine regression. Results of different tree nodes are integrated through weighted average method to obtain the comprehensive forecasting result. The effectiveness of the proposed method is demonstrated through its application to an actual system. (author)

  12. Intracavity Laser Photoacoustic Spectrometer with High Sensitivity

    International Nuclear Information System (INIS)

    Mitrayana; Muslim; Wasono, M.A.J.

    2002-01-01

    A photo acoustic spectrometer set-up has been upgraded from an extra cavity into an intracavity configuration using a sealed-off CO 2 laser as the spectrometer's radiation source. The detection level of the upgrade Intracavity Photoacoustic Spectrometer (IPS) reached (200 ± 50) ppt for C 2 H 4 and (20 ± 5) ppt for SF 6 with response time (6.6 ± 0.2) s. (author)

  13. Evaluation of the ROTAX spectrometer

    International Nuclear Information System (INIS)

    Tietze-Jaensch, H.; Schmidt, W.; Geick, R.

    1997-01-01

    After installation of the new-type rotating crystal analyser spectrometer ROTAX at ISIS, we report on practical experience and describe its current status. The rotating analyser technique works feasibly and reliably and provides an ultimate scan flexibility on a pulsed time-of-flight neutron spectrometer. The spinning analyser achieves a mulitplex advantage factor of ca. 50 without compromising the resolution of the instrument. Despite these instrument merits its individual beam position at ISIS has only an unsatisfactorily weak flux, thus hindering this instrument yet to become fully competitive with other high-performance neutron spectrometers based at high-flux reactors. However, we strongly recommend a ROTAX-type instrument to be emphasized when the instrumentation suite of the future European spallation source ESS will come under scrutiny. (orig.)

  14. The Time Course of Incremental Word Processing during Chinese Reading

    Science.gov (United States)

    Zhou, Junyi; Ma, Guojie; Li, Xingshan; Taft, Marcus

    2018-01-01

    In the current study, we report two eye movement experiments investigating how Chinese readers process incremental words during reading. These are words where some of the component characters constitute another word (an embedded word). In two experiments, eye movements were monitored while the participants read sentences with incremental words…

  15. Use of an A.E.I. MS 10 mass spectrometer for 40Ar-39Ar dating

    International Nuclear Information System (INIS)

    Baksi, A.K.

    1979-01-01

    The use of an AEI mass spectrometer for 40 Ar/ 39 Ar dating could, in principle, be problematical due to its limited mass resolution and because of non-linear mass discrimination under certain operating conditions. These possible drawbacks have been investigated and are found to be easy to overcome. Tailing corrections are relatively small and can be applied precisely for 40 Ar/ 39 Ar ratios <= 300. By operating the instrument with a trap current of 50 μA and an ion repeller voltage of +1.0 w.r.t. cage, problems due to non-linear mass discrimination are eliminated. Using the incremental heating technique and total fusion studies on very small subsamples (10-25 mg.), the homogeneity of some well-known inter-laboratory standards has been investigated; the relative merits of these standards are discussed. (K.B.)

  16. Switch-mode High Voltage Drivers for Dielectric Electro Active Polymer (DEAP) Incremental Actuators

    DEFF Research Database (Denmark)

    Thummala, Prasanth

    voltage DC-DC converters for driving the DEAP based incremental actuators. The DEAP incremental actuator technology has the potential to be used in various industries, e.g., automotive, space and medicine. The DEAP incremental actuator consists of three electrically isolated and mechanically connected...

  17. Efficient Incremental Checkpointing of Java Programs

    DEFF Research Database (Denmark)

    Lawall, Julia Laetitia; Muller, Gilles

    2000-01-01

    This paper investigates the optimization of language-level checkpointing of Java programs. First, we describe how to systematically associate incremental checkpoints with Java classes. While being safe, the genericness of this solution induces substantial execution overhead. Second, to solve...

  18. Gamma-ray spectrometer utilizing xenon at high pressure

    International Nuclear Information System (INIS)

    Smith, G.C.; Mahler, G.J.; Yu, B.; Kane, W.R.; Markey, J.K.

    1994-01-01

    A prototype gamma-ray spectrometer utilizing xenon gas near the critical point (166 degrees C, 58 atm) is under development. The spectrometer will function as a room-temperature ionization chamber detecting gamma rays in the energy range 100 keV2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. The energy resolution is superior to that of a NaI scintillation spectrometer by a substantial margin (approximately a factor 5), and accordingly, much more information can be extracted from a given gamma-ray spectrum. Unlike germanium detectors, the spectrometer possesses the capability for sustained operation under ambient temperature conditions without a requirement for liquid nitrogen

  19. Miniature Raman spectrometer development

    Science.gov (United States)

    Bonvallet, Joseph; Auz, Bryan; Rodriguez, John; Olmstead, Ty

    2018-02-01

    The development of techniques to rapidly identify samples ranging from, molecule and particle imaging to detection of high explosive materials, has surged in recent years. Due to this growing want, Raman spectroscopy gives a molecular fingerprint, with no sample preparation, and can be done remotely. These systems can be small, compact, lightweight, and with a user interface that allows for easy use and sample identification. Ocean Optics Inc. has developed several systems that would meet all these end user requirements. This talk will describe the development of different Ocean Optics Inc miniature Raman spectrometers. The spectrometer on a phone (SOAP) system was designed using commercial off the shelf (COTS) components, in a rapid product development cycle. The footprint of the system measures 40x40x14 mm (LxWxH) and was coupled directly to the cell phone detector camera optics. However, it gets roughly only 40 cm-1 resolution. The Accuman system is the largest (290x220X100 mm) of the three, but uses our QEPro spectrometer and get 7-11 cm-1 resolution. Finally, the HRS-30 measuring 165x85x40 mm is a combination of the other two systems. This system uses a modified EMBED spectrometer and gets 7-12 cm-1 resolution. Each of these units uses a peak matching algorithm that then correlates the results to the pre-loaded and customizable spectral libraries.

  20. Single-point incremental forming and formability-failure diagrams

    DEFF Research Database (Denmark)

    Silva, M.B.; Skjødt, Martin; Atkins, A.G.

    2008-01-01

    In a recent work [1], the authors constructed a closed-form analytical model that is capable of dealing with the fundamentals of single point incremental forming and explaining the experimental and numerical results published in the literature over the past couple of years. The model is based...... of deformation that are commonly found in general single point incremental forming processes; and (ii) to investigate the formability limits of SPIF in terms of ductile damage mechanics and the question of whether necking does, or does not, precede fracture. Experimentation by the authors together with data...

  1. Complex Incremental Product Innovation in Established Service Firms: A Micro Institutional Perspective

    OpenAIRE

    Vermeulen, Patrick; Bosch, Frans; Volberda, Henk

    2007-01-01

    textabstractMany product innovation studies have described key determinants that should lead to successful incremental product innovation. Despite numerous studies suggesting how incremental product innovation should be successfully undertaken, many firms still struggle with this type of innovation. In this paper, we use an institutional perspective to investigate why established firms in the financial services industry struggle with their complex incremental product innovation efforts. We ar...

  2. Incremental Innovation and Competitive Pressure in the Presence of Discrete Innovation

    DEFF Research Database (Denmark)

    Ghosh, Arghya; Kato, Takao; Morita, Hodaka

    2017-01-01

    Technical progress consists of improvements made upon the existing technology (incremental innovation) and innovative activities aiming at entirely new technology (discrete innovation). Incremental innovation is often of limited relevance to the new technology invented by successful discrete...

  3. Imaging spectrometer using a liquid crystal tunable filter

    Science.gov (United States)

    Chrien, Thomas G.; Chovit, Christopher; Miller, Peter J.

    1993-09-01

    A demonstration imaging spectrometer using a liquid crystal tunable filter (LCTF) was built and tested on a hot air balloon platform. The LCTF is a tunable polarization interference or Lyot filter. The LCTF enables a small, light weight, low power, band sequential imaging spectrometer design. An overview of the prototype system is given along with a description of balloon experiment results. System model performance predictions are given for a future LCTF based imaging spectrometer design. System design considerations of LCTF imaging spectrometers are discussed.

  4. Some conceptual designs for a LASSY spectrometer magnet

    International Nuclear Information System (INIS)

    Green, M.A.

    1995-09-01

    The LASSY spectrometer is a gas filled spectrometer (hydrogen or helium at a pressure of about 1 torr). The design bending power for the primary bending magnet for the spectrometer will have an induction bend radius product of 2.5 tesla-meters. In order to increase the acceptance of the spectrometer, the bending magnet system must be located close to the target where the desired nuclei are created. The spectrometer magnet system must consist of both bending and focusing elements so that the wide acceptance of particles can be brought to a focus at the analysis point that is down stream from the last magnet element. In order improve the spectrometer resolution and to catch the shortest lived nuclei, the length of the magnet system must be as short as possible. The length for the LASSY spectrometer magnet system from the target to the analysis point has been set at 2.5 meters or less. To improve the resolution of the spectrometer, the bending angle for bending magnet system must be increased to close to 180 degrees. In order to achieve a large bending angle and a short magnet system length, the bending induction must be above 3 tesla and the focusing elements must be combined with the bending elements. As a result, a LASSY spectrometer will have bending magnet with a bending angle from 140 to 170 degrees. This magnet win be combined with one or more focusing magnets (a straight dipole in some places and a combined function dipole in other places). The result is a single superconducting bending magnet with one or more quadrupoles incorporated within the large angle bending magnet

  5. Calculation of the increment reduction in spruce stands by charcoal smoke

    Energy Technology Data Exchange (ETDEWEB)

    Guede, J

    1954-01-01

    Chronic damage to spruce trees by charcoal smoke, often hardly noticeable from outward appearance but causing marked reductions of wood increment can be determined by means of a calculation by increment cores. Sulfurous acid anhydride causes the closure of the stomates of needles by which the circulation of water is checked. The assimilation and the wood increment are reduced. The cores are taken from uninjured trees belonging to the dominant class. These trees are liable to irregular variations in the trend of growth only by atmospheric influences and disturbances in the circulation of water. The decrease of increment of a stand can be judged by the trend of growth of the basal area of sample trees. Two methods are applied: in the first method, the difference between the mean total increment before the damage has been caused and that after it is calculated by the yield table in deriving the site quality classes from the basal area growth of dominant stems. This is possible by using the mean diameter of each age class and the frequency curve of basal area for each site class. In the other method, the reduction of basal area increment of sample trees is measured directly. The total reduction of a stand can be judged by the share of the dominant class of stem in the total current growth of the basal area of a sound stand and by the percent of reduction of the sample trees.

  6. Micro Plasma Spectrometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this IRAD project is to develop a preliminary design elements of miniature electron and ion plasma spectrometers and supporting electronics, focusing...

  7. The research of digital circuit system for high accuracy CCD of portable Raman spectrometer

    Science.gov (United States)

    Yin, Yu; Cui, Yongsheng; Zhang, Xiuda; Yan, Huimin

    2013-08-01

    The Raman spectrum technology is widely used for it can identify various types of molecular structure and material. The portable Raman spectrometer has become a hot direction of the spectrometer development nowadays for its convenience in handheld operation and real-time detection which is superior to traditional Raman spectrometer with heavy weight and bulky size. But there is still a gap for its measurement sensitivity between portable and traditional devices. However, portable Raman Spectrometer with Shell-Isolated Nanoparticle-Enhanced Raman Spectroscopy (SHINERS) technology can enhance the Raman signal significantly by several orders of magnitude, giving consideration in both measurement sensitivity and mobility. This paper proposed a design and implementation of driver and digital circuit for high accuracy CCD sensor, which is core part of portable spectrometer. The main target of the whole design is to reduce the dark current generation rate and increase signal sensitivity during the long integration time, and in the weak signal environment. In this case, we use back-thinned CCD image sensor from Hamamatsu Corporation with high sensitivity, low noise and large dynamic range. In order to maximize this CCD sensor's performance and minimize the whole size of the device simultaneously to achieve the project indicators, we delicately designed a peripheral circuit for the CCD sensor. The design is mainly composed with multi-voltage circuit, sequential generation circuit, driving circuit and A/D transition parts. As the most important power supply circuit, the multi-voltage circuits with 12 independent voltages are designed with reference power supply IC and set to specified voltage value by the amplifier making up the low-pass filter, which allows the user to obtain a highly stable and accurate voltage with low noise. What's more, to make our design easy to debug, CPLD is selected to generate sequential signal. The A/D converter chip consists of a correlated

  8. Do otolith increments allow correct inferences about age and growth of coral reef fishes?

    Science.gov (United States)

    Booth, D. J.

    2014-03-01

    Otolith increment structure is widely used to estimate age and growth of marine fishes. Here, I test the accuracy of the long-term otolith increment analysis of the lemon damselfish Pomacentrus moluccensis to describe age and growth characteristics. I compare the number of putative annual otolith increments (as a proxy for actual age) and widths of these increments (as proxies for somatic growth) with actual tagged fish-length data, based on a 6-year dataset, the longest time course for a coral reef fish. Estimated age from otoliths corresponded closely with actual age in all cases, confirming annual increment formation. However, otolith increment widths were poor proxies for actual growth in length [linear regression r 2 = 0.44-0.90, n = 6 fish] and were clearly of limited value in estimating annual growth. Up to 60 % of the annual growth variation was missed using otolith increments, suggesting the long-term back calculations of otolith growth characteristics of reef fish populations should be interpreted with caution.

  9. The Dark Side of Malleability: Incremental Theory Promotes Immoral Behaviors.

    Science.gov (United States)

    Huang, Niwen; Zuo, Shijiang; Wang, Fang; Cai, Pan; Wang, Fengxiang

    2017-01-01

    Implicit theories drastically affect an individual's processing of social information, decision making, and action. The present research focuses on whether individuals who hold the implicit belief that people's moral character is fixed (entity theorists) and individuals who hold the implicit belief that people's moral character is malleable (incremental theorists) make different choices when facing a moral decision. Incremental theorists are less likely to make the fundamental attribution error (FAE), rarely make moral judgment based on traits and show more tolerance to immorality, relative to entity theorists, which might decrease the possibility of undermining the self-image when they engage in immoral behaviors, and thus we posit that incremental beliefs facilitate immorality. Four studies were conducted to explore the effect of these two types of implicit theories on immoral intention or practice. The association between implicit theories and immoral behavior was preliminarily examined from the observer perspective in Study 1, and the results showed that people tended to associate immoral behaviors (including everyday immoral intention and environmental destruction) with an incremental theorist rather than an entity theorist. Then, the relationship was further replicated from the actor perspective in Studies 2-4. In Study 2, implicit theories, which were measured, positively predicted the degree of discrimination against carriers of the hepatitis B virus. In Study 3, implicit theories were primed through reading articles, and the participants in the incremental condition showed more cheating than those in the entity condition. In Study 4, implicit theories were primed through a new manipulation, and the participants in the unstable condition (primed incremental theory) showed more discrimination than those in the other three conditions. Taken together, the results of our four studies were consistent with our hypotheses.

  10. The Dark Side of Malleability: Incremental Theory Promotes Immoral Behaviors

    Directory of Open Access Journals (Sweden)

    Niwen Huang

    2017-08-01

    Full Text Available Implicit theories drastically affect an individual’s processing of social information, decision making, and action. The present research focuses on whether individuals who hold the implicit belief that people’s moral character is fixed (entity theorists and individuals who hold the implicit belief that people’s moral character is malleable (incremental theorists make different choices when facing a moral decision. Incremental theorists are less likely to make the fundamental attribution error (FAE, rarely make moral judgment based on traits and show more tolerance to immorality, relative to entity theorists, which might decrease the possibility of undermining the self-image when they engage in immoral behaviors, and thus we posit that incremental beliefs facilitate immorality. Four studies were conducted to explore the effect of these two types of implicit theories on immoral intention or practice. The association between implicit theories and immoral behavior was preliminarily examined from the observer perspective in Study 1, and the results showed that people tended to associate immoral behaviors (including everyday immoral intention and environmental destruction with an incremental theorist rather than an entity theorist. Then, the relationship was further replicated from the actor perspective in Studies 2–4. In Study 2, implicit theories, which were measured, positively predicted the degree of discrimination against carriers of the hepatitis B virus. In Study 3, implicit theories were primed through reading articles, and the participants in the incremental condition showed more cheating than those in the entity condition. In Study 4, implicit theories were primed through a new manipulation, and the participants in the unstable condition (primed incremental theory showed more discrimination than those in the other three conditions. Taken together, the results of our four studies were consistent with our hypotheses.

  11. Dental caries increments and related factors in children with type 1 diabetes mellitus.

    Science.gov (United States)

    Siudikiene, J; Machiulskiene, V; Nyvad, B; Tenovuo, J; Nedzelskiene, I

    2008-01-01

    The aim of this study was to analyse possible associations between caries increments and selected caries determinants in children with type 1 diabetes mellitus and their age- and sex-matched non-diabetic controls, over 2 years. A total of 63 (10-15 years old) diabetic and non-diabetic pairs were examined for dental caries, oral hygiene and salivary factors. Salivary flow rates, buffer effect, concentrations of mutans streptococci, lactobacilli, yeasts, total IgA and IgG, protein, albumin, amylase and glucose were analysed. Means of 2-year decayed/missing/filled surface (DMFS) increments were similar in diabetics and their controls. Over the study period, both unstimulated and stimulated salivary flow rates remained significantly lower in diabetic children compared to controls. No differences were observed in the counts of lactobacilli, mutans streptococci or yeast growth during follow-up, whereas salivary IgA, protein and glucose concentrations were higher in diabetics than in controls throughout the 2-year period. Multivariable linear regression analysis showed that children with higher 2-year DMFS increments were older at baseline and had higher salivary glucose concentrations than children with lower 2-year DMFS increments. Likewise, higher 2-year DMFS increments in diabetics versus controls were associated with greater increments in salivary glucose concentrations in diabetics. Higher increments in active caries lesions in diabetics versus controls were associated with greater increments of dental plaque and greater increments of salivary albumin. Our results suggest that, in addition to dental plaque as a common caries risk factor, diabetes-induced changes in salivary glucose and albumin concentrations are indicative of caries development among diabetics. Copyright 2008 S. Karger AG, Basel.

  12. Compact Spectrometers Based on Linear Variable Filters

    Data.gov (United States)

    National Aeronautics and Space Administration — Demonstrate a linear-variable spectrometer with an H2RG array. Linear Variable Filter (LVF) spectrometers provide attractive resource benefits – high optical...

  13. Combined corona discharge and UV photoionization source for ion mobility spectrometry.

    Science.gov (United States)

    Bahrami, Hamed; Tabrizchi, Mahmoud

    2012-08-15

    An ion mobility spectrometer is described which is equipped with two non-radioactive ion sources, namely an atmospheric pressure photoionization and a corona discharge ionization source. The two sources cannot only run individually but are additionally capable of operating simultaneously. For photoionization, a UV lamp was mounted parallel to the axis of the ion mobility cell. The corona discharge electrode was mounted perpendicular to the UV radiation. The total ion current from the photoionization source was verified as a function of lamp current, sample flow rate, and drift field. Simultaneous operation of the two ionization sources was investigated by recording ion mobility spectra of selected samples. The design allows one to observe peaks from either the corona discharge or photoionization individually or simultaneously. This makes it possible to accurately compare peaks in the ion mobility spectra from each individual source. Finally, the instrument's capability for discriminating two peaks appearing in approximately identical drift times using each individual ionization source is demonstrated. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Spectrometer for neutron inelastic scattering investigations of microsamples

    International Nuclear Information System (INIS)

    Balagurov, A.M.; Kozlenko, D.P.; Platonov, S.L.; Savenko, B.N.; Glazkov, V.P.; Krasnikov, Yu.M.; Naumov, I.V.; Pukhov, A.V.; Somenkov, V.A.; Syrykh, G.F.

    1997-01-01

    A new neutron spectrometer for investigation of inelastic neutron scattering on polycrystal microsamples under high pressure in sapphire and diamond anvils cells is described. The spectrometer is operating at the IBR-2 pulsed reactor in JINR. Parameters and methodical peculiarities of the spectrometer and the examples of experimental studies are given. (author)

  15. High level bacterial contamination of secondary school students' mobile phones.

    Science.gov (United States)

    Kõljalg, Siiri; Mändar, Rando; Sõber, Tiina; Rööp, Tiiu; Mändar, Reet

    2017-06-01

    While contamination of mobile phones in the hospital has been found to be common in several studies, little information about bacterial abundance on phones used in the community is available. Our aim was to quantitatively determine the bacterial contamination of secondary school students' mobile phones. Altogether 27 mobile phones were studied. The contact plate method and microbial identification using MALDI-TOF mass spectrometer were used for culture studies. Quantitative PCR reaction for detection of universal 16S rRNA, Enterococcus faecalis 16S rRNA and Escherichia coli allantoin permease were performed, and the presence of tetracycline ( tet A, tet B, tet M), erythromycin ( erm B) and sulphonamide ( sul 1) resistance genes was assessed. We found a high median bacterial count on secondary school students' mobile phones (10.5 CFU/cm 2 ) and a median of 17,032 bacterial 16S rRNA gene copies per phone. Potentially pathogenic microbes ( Staphylococcus aureus , Acinetobacter spp. , Pseudomonas spp., Bacillus cereus and Neisseria flavescens ) were found among dominant microbes more often on phones with higher percentage of E. faecalis in total bacterial 16S rRNA. No differences in contamination level or dominating bacterial species between phone owner's gender and between phone types (touch screen/keypad) were found. No antibiotic resistance genes were detected on mobile phone surfaces. Quantitative study methods revealed high level bacterial contamination of secondary school students' mobile phones.

  16. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  17. Chemical Characterization of Nuclear Materials: Development a New Combined X-Ray Fluorescence and Raman Spectrometer

    International Nuclear Information System (INIS)

    Szaloki, I.; Gerenyi, A.

    2015-01-01

    New mobile analytical device based on combination of X-ray fluorescence and Raman spectrometer has been developed for prompt and quantitative characterization of chemical component from Al to U in nuclear waste or undeclared materials. The excitation source of the X-ray fluorescence spectrometer is an air-cooled X-ray tube with Ag transmission anode. For collection of secondary X-ray photons and data processing, a compact Amptek X-ray detector system is applied with silicon drift X-ray detector. The XRF system operates in confocal mode with focal volume around 1-4 mm 3 . Varying the geometrical position and orientation of the sample optional part of its surface can be analyzed. The Raman unit includes thermoelectrically cooled laser source having 500 mW power at wavelength 785 nm. In order to obtain spectral information from sample surface a reflection-type probe is connected by optical fibres to the Raman spectrometer. A mini focusing optics is set up to the sensor-fibre that provides the system to operate as confocal optical device in reflection mode. The XRF spectrometer with X-ray detector, Raman probe and X-ray tube are mechanically fixed and hermetically connected to an aluminium chamber, which can be optionally filled with helium. The chamber is mounted on a vertical stage that provides moving it to the sample surface. A new model and computer code have been developed for XRF quantitative analysis which describes the mathematical relationship between the concentration of sample elements and their characteristic X-ray intensities. For verification of the calculations standard reference alloy samples were measured. The results was in good agreement with certified concentrations in range of 0.001-100 w%. According to these numerical results this new method is successfully applicable for quick and non-destructive quantitative analysis of waste materials without using standard samples. (author)

  18. RITA: The reinvented triple axis spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mason, T.E. [Toronto Univ., ON (Canada). Dept. of Physics; Clausen, K.N.; Aeppli, G.; McMorrow, D.R.; Kjems, J.K. [Risoe National Lab., Roskilde (Denmark)

    1995-11-01

    Risoe National Laboratory was reported to be in the process of developing a new spectrometer design, RITA, based on the triple axis design. The spectrometer will attempt to incorporate more recent innovations such as multilayer supermirrors and microstrip proportional counters into a rethinking of the triple-axis spectrometer. By optimizing the beam optics, using supermirrors and extending the analyser to map regions of (Q, {omega}) space using an array of independently controllable pyrolytic graphite crystals focussed on an area detector, it was hoped that the efficiency of single-crystal inelastic experiments could be increased by as much as a factor of 20. 7 figs., 20 refs.

  19. Enabling Incremental Query Re-Optimization.

    Science.gov (United States)

    Liu, Mengmeng; Ives, Zachary G; Loo, Boon Thau

    2016-01-01

    As declarative query processing techniques expand to the Web, data streams, network routers, and cloud platforms, there is an increasing need to re-plan execution in the presence of unanticipated performance changes. New runtime information may affect which query plan we prefer to run. Adaptive techniques require innovation both in terms of the algorithms used to estimate costs , and in terms of the search algorithm that finds the best plan. We investigate how to build a cost-based optimizer that recomputes the optimal plan incrementally given new cost information, much as a stream engine constantly updates its outputs given new data. Our implementation especially shows benefits for stream processing workloads. It lays the foundations upon which a variety of novel adaptive optimization algorithms can be built. We start by leveraging the recently proposed approach of formulating query plan enumeration as a set of recursive datalog queries ; we develop a variety of novel optimization approaches to ensure effective pruning in both static and incremental cases. We further show that the lessons learned in the declarative implementation can be equally applied to more traditional optimizer implementations.

  20. Mobile contract services: what you need to know.

    Science.gov (United States)

    Inman, M

    2000-01-01

    With sufficient planning and ongoing attention to detail, the performance of a mobile imaging service provider can exceed expectations and requirements. The relationship can prove to be mutually agreeable and profitable for many years. But, when contracting mobile services, you cannot spend too much time on initial research and detail. Several scenarios present outsourcing or mobile services as an acceptable alternative to purchase or lease: outdated equipment, novel or under-utilized technologies, the need for incrementally added or temporary service. To find suitable providers, check with peer sources in your area for recommendations; look specifically for facilities that are comparable in size and volume to your facility. Expect that larger volume facilities will rate more favorable schedules or pricing. Obtain and check references. Require mobile service providers to adhere to the same state and federal laws, rules and regulations that govern your facility; receive the assurance of compliance in writing if it is not specifically addressed in the contract. JCAHO requires that any contract service provider be governed by the same requirements as the accredited facility. Several other rules or licensing requirements may also pertain to mobile services. A prevailing reason for outsourcing imaging services is high equipment costs that cannot be justified with current volume projections. However, equipment quality should not be compromised; it must meet your needs and be in good repair. The mobile service provider you choose should be an extension of your department; quality standards must exist unilaterally. The set rule for assessing mobile service fees is that there is no set rule. There are many ways to negotiate the fee schedule so that it meets the needs of both parties. An effective marketing campaign lets physicians and patients know what you have available. Work with the mobile service provider to plan an initial announcement or open house. The mobile

  1. High resolution 14 MeV neutron spectrometer

    International Nuclear Information System (INIS)

    Pillon, M.

    1986-01-01

    A neutron spectrometer, based both on the track position identification and the energy measurement of recoiling protons from a hydrogenous radiator is proposed. The expected performance limits of this spectrometer with regard to energy resolution (deltaE/E), efficiency (epsilon) and counting rate are evaluated in five different configurations. The results show the possibility of deriving an optimized spectrometer design for applications on large fusion devices such as JET and NET with an energy resolution up 1% at 14 MeV

  2. RADIO-FREQUENCY MASS SPECTROMETERS AND THEIR APPLICATIONS IN SPACE

    Energy Technology Data Exchange (ETDEWEB)

    Gilmour, Jr., A. S.

    1963-08-15

    The operation of three common radio-frequency mass spectrometers is described, and their performances are compared. Their limitations are pointed out. It is concluded that the quadrupole spectrometer has fewer limitations and is more generally useful in space probes than the other devices. Some present and proposed uses of spectrometers in space are discussed, and the problem of contamination of the atmosphere being sampled by the spectrometer is reviewed. (auth)

  3. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which is consisted of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for filed geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  4. The portable micro-computerized multichannel spectrometer for geological application

    International Nuclear Information System (INIS)

    Fang Fang; Jia Wenyi; Zhou Rongsheng; Ma Yingjie; Zhou Jianbin

    1999-01-01

    The portable micro-computerized multichannel spectrometer is based on the book computer and employs the A/D integrated circuit with 12 bits. It is a 2048 channel spectrometer which consists of hardware and software. The author analyzed the hardware circuit and software construction of the micro-computerized multichannel spectrometer which is suitable for field geological application. The main technical specifications and application of the new multichannel spectrometer were also discussed

  5. Corona discharge ion mobility spectrometry at reduced pressures

    International Nuclear Information System (INIS)

    Tabrizchi, Mahmoud; Rouholahnejad, Fereshteh

    2004-01-01

    Ion mobility spectrometers (IMSs) normally operate at ambient pressure. In this work an IMS cell has been designed and constructed to allow the pressure to be reduced inside the IMS cell. In this cell, corona discharge was employed as the ionization source. Reducing pressure affected both the discharge and the performance of the IMS. The discharge current was observed to increase with reducing pressure while the ignition potential decreased. The ion current received at the collector plate was also increased about 50 times when the pressure was reduced from ambient pressure to 15 Torr. The higher ion current can lead to an extended dynamic range. IMS spectra were recorded at various pressures and the results show that the drift times shift perfectly linear with pressure. This suggests that unlike temperature, pressure correction for ion mobility spectra is as simple as multiplying the drift times by a factor of 760/P

  6. Artificial intelligence for geologic mapping with imaging spectrometers

    Science.gov (United States)

    Kruse, F. A.

    1993-01-01

    This project was a three year study at the Center for the Study of Earth from Space (CSES) within the Cooperative Institute for Research in Environmental Science (CIRES) at the University of Colorado, Boulder. The goal of this research was to develop an expert system to allow automated identification of geologic materials based on their spectral characteristics in imaging spectrometer data such as the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This requirement was dictated by the volume of data produced by imaging spectrometers, which prohibits manual analysis. The research described is based on the development of automated techniques for analysis of imaging spectrometer data that emulate the analytical processes used by a human observer. The research tested the feasibility of such an approach, implemented an operational system, and tested the validity of the results for selected imaging spectrometer data sets.

  7. Polarized epithermal neutron spectrometer at KENS

    International Nuclear Information System (INIS)

    Kohgi, M.

    1983-01-01

    A spectrometer employing a white, epithermal, polarized neutron beam is under construction at KENS. The neutron polarization is achieved by passage through a dynamically polarized proton filter (DPPF). The results of the test experiments show that the DPPF method is promising in obtaining polarized epithermal neutron beam. The basic design of the spectrometer is described

  8. Calculational approach to ionization spectrometer design

    International Nuclear Information System (INIS)

    Gabriel, T.A.

    1974-01-01

    Many factors contribute to the design and overall performance of an ionization spectrometer. These factors include the conditions under which the spectrometer is to be used, the required performance, the development of the hadronic and electromagnetic cascades, leakage and binding energies, saturation effects of densely ionizing particles, nonuniform light collection, sampling fluctuations, etc. The calculational procedures developed at Oak Ridge National Laboratory that have been applied to many spectrometer designs and that include many of the influencing factors in spectrometer design are discussed. The incident-particle types which can be considered with some generality are protons, neutrons, pions, muons, electrons, positrons, and gamma rays. Charged kaons can also be considered but with less generality. The incident-particle energy range can extend into the hundreds of GeV range. The calculations have been verified by comparison with experimental data but only up to approximately 30 GeV. Some comparisons with experimental data are also discussed and presented so that the flexibility of the calculational methods can be demonstrated. (U.S.)

  9. Fast-response personal Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Kholmetskij, A.L.; Mashlan, M.; Misevich, O.V.; Evdokimov, V.A.; Lopatik, A.R.; Zhak, D.; Fedorov, A.A.; Snashel, V.

    1995-01-01

    Spectrometer design to record transmission Moessbauer spectra is described. The spectrometer consists of PC/AT computer with 1 mb memory and 40 mb hard disk, of EPSON LX 850 printer, of color monitor with VGA graphical adapter, of data accumulation system, of speed generator, of motion system with minivibrator, of scintillation detector with YA10 3 :Ce scintillator, of single-channel amplitude analyzer, of measuring bench and of 57 Co(Rh) source. 1 ref.; 1 fig

  10. The BTeV main spectrometer

    International Nuclear Information System (INIS)

    Sheldon, P.D.

    2001-01-01

    BTeV is a second generation B-factory experiment that will use a double-arm, forward spectrometer in the C0 experimental hall at the Fermilab Tevatron. I will describe the motivation and design of the 'main spectrometer', consisting of a ring-imaging Cherenkov system for charged particle identification, an electromagnetic calorimeter of lead-tungstate crystals, a proportional tube muon system with magnetized filtering steel, and a straw-tube and silicon strip charged particle tracking system

  11. Miniature neutron-alpha activation spectrometer

    International Nuclear Information System (INIS)

    Rhodes, Edgar; Goldsten, John; Holloway, James Paul; He, Zhong

    2002-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in-situ analysis of chem-bio samples, including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform for Mars or outer-planet missions. In the neutron-activation mode, penetrating analysis will be performed of the whole sample using a γ spectrometer and in the α-activation mode, the sample surface will be analyzed using Rutherford-backscatter and x-ray spectrometers. Novel in our approach is the development of a switchable radioactive neutron source and a small high-resolution γ detector. The detectors and electronics will benefit from remote unattended operation capabilities resulting from our NEAR XGRS heritage and recent development of a Ge γ detector for MESSENGER. Much of the technology used in this instrument can be adapted to portable or unattended terrestrial applications for detection of explosives, chemical toxins, nuclear weapons, and contraband

  12. Use of an ion mobility spectrometer for detecting uranium compounds.

    Science.gov (United States)

    McLain, Derek R; Steeb, Jennifer L; Smith, Nicholas A

    2018-07-01

    The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown the ability to supply chemical information on the compounds analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. This work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Context-dependent incremental timing cells in the primate hippocampus.

    Science.gov (United States)

    Sakon, John J; Naya, Yuji; Wirth, Sylvia; Suzuki, Wendy A

    2014-12-23

    We examined timing-related signals in primate hippocampal cells as animals performed an object-place (OP) associative learning task. We found hippocampal cells with firing rates that incrementally increased or decreased across the memory delay interval of the task, which we refer to as incremental timing cells (ITCs). Three distinct categories of ITCs were identified. Agnostic ITCs did not distinguish between different trial types. The remaining two categories of cells signaled time and trial context together: One category of cells tracked time depending on the behavioral action required for a correct response (i.e., early vs. late release), whereas the other category of cells tracked time only for those trials cued with a specific OP combination. The context-sensitive ITCs were observed more often during sessions where behavioral learning was observed and exhibited reduced incremental firing on incorrect trials. Thus, single primate hippocampal cells signal information about trial timing, which can be linked with trial type/context in a learning-dependent manner.

  14. Statistics of wind direction and its increments

    International Nuclear Information System (INIS)

    Doorn, Eric van; Dhruva, Brindesh; Sreenivasan, Katepalli R.; Cassella, Victor

    2000-01-01

    We study some elementary statistics of wind direction fluctuations in the atmosphere for a wide range of time scales (10 -4 sec to 1 h), and in both vertical and horizontal planes. In the plane parallel to the ground surface, the direction time series consists of two parts: a constant drift due to large weather systems moving with the mean wind speed, and fluctuations about this drift. The statistics of the direction fluctuations show a rough similarity to Brownian motion but depend, in detail, on the wind speed. This dependence manifests itself quite clearly in the statistics of wind-direction increments over various intervals of time. These increments are intermittent during periods of low wind speeds but Gaussian-like during periods of high wind speeds. (c) 2000 American Institute of Physics

  15. The LASS [Larger Aperture Superconducting Solenoid] spectrometer

    International Nuclear Information System (INIS)

    Aston, D.; Awaji, N.; Barnett, B.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K + and K - interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K - p interactions during 1977 and 1978, which is also described briefly

  16. The LASS (Larger Aperture Superconducting Solenoid) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Aston, D.; Awaji, N.; Barnett, B.; Bienz, T.; Bierce, R.; Bird, F.; Bird, L.; Blockus, D.; Carnegie, R.K.; Chien, C.Y.

    1986-04-01

    LASS is the acronym for the Large Aperture Superconducting Solenoid spectrometer which is located in an rf-separated hadron beam at the Stanford Linear Accelerator Center. This spectrometer was constructed in order to perform high statistics studies of multiparticle final states produced in hadron reactions. Such reactions are frequently characterized by events having complicated topologies and/or relatively high particle multiplicity. Their detailed study requires a spectrometer which can provide good resolution in momentum and position over almost the entire solid angle subtended by the production point. In addition, good final state particle identification must be available so that separation of the many kinematically-overlapping final states can be achieved. Precise analyses of the individual reaction channels require high statistics, so that the spectrometer must be capable of high data-taking rates in order that such samples can be acquired in a reasonable running time. Finally, the spectrometer must be complemented by a sophisticated off-line analysis package which efficiently finds tracks, recognizes and fits event topologies and correctly associates the available particle identification information. This, together with complicated programs which perform specific analysis tasks such as partial wave analysis, requires a great deal of software effort allied to a very large computing capacity. This paper describes the construction and performance of the LASS spectrometer, which is an attempt to realize the features just discussed. The configuration of the spectrometer corresponds to the data-taking on K and K interactions in hydrogen at 11 GeV/c which took place in 1981 and 1982. This constitutes a major upgrade of the configuration used to acquire lower statistics data on 11 GeV/c K p interactions during 1977 and 1978, which is also described briefly.

  17. Incremental Beliefs of Ability, Achievement Emotions and Learning of Singapore Students

    Science.gov (United States)

    Luo, Wenshu; Lee, Kerry; Ng, Pak Tee; Ong, Joanne Xiao Wei

    2014-01-01

    This study investigated the relationships of students' incremental beliefs of math ability to their achievement emotions, classroom engagement and math achievement. A sample of 273 secondary students in Singapore were administered measures of incremental beliefs of math ability, math enjoyment, pride, boredom and anxiety, as well as math classroom…

  18. Optimization of time-correlated single photon counting spectrometer

    International Nuclear Information System (INIS)

    Zhang Xiufeng; Du Haiying; Sun Jinsheng

    2011-01-01

    The paper proposes a performance improving scheme for the conventional time-correlated single photon counting spectrometer and develops a high speed data acquisition card based on PCI bus and FPGA technologies. The card is used to replace the multi-channel analyzer to improve the capability and decrease the volume of the spectrometer. The process of operation is introduced along with the integration of the spectrometer system. Many standard samples are measured. The experimental results show that the sensitivity of the spectrometer is single photon counting, and the time resolution of fluorescence lifetime measurement can be picosecond level. The instrument could measure the time-resolved spectroscopy. (authors)

  19. Development of a cosmic veto gamma-spectrometer

    International Nuclear Information System (INIS)

    Burnett, J.L.; Davies, A.V.

    2012-01-01

    Cosmic radiation contributes significantly towards the background radiation measured by a gamma-spectrometer. A novel cosmic veto gamma-spectrometer has been developed that provides a mean background reduction of 54.5%. The system consists of plastic scintillation plates operated in time-stamp mode to detect coincident muon interactions within an HPGe gamma-spectrometer. The instrument is easily configurable and provides improved sensitivity for radionuclides indicative of nuclear weapons tests and reactor incidents, including 140 Ba, 95 Zr, 99 Mo, 141 Ce, 147 Nd, 131 I, 134 Cs and 137 Cs. This has been demonstrated for Comprehensive Nuclear-Test-Ban Treaty applications to obtain the required 140 Ba MDA of 24 mBq within 2 days counting. Analysis of an air filter sample collected during the Fukushima incident indicates improved sensitivity compared to conventional gamma-spectrometers. (author)

  20. Development of triple axis neutron spectrometer (Paper No. 24)

    International Nuclear Information System (INIS)

    Pal, B.C.; Wadhwa, N.R.; Goveas, S.H.

    1987-02-01

    The triple axis neutron spectrometers are the basic instruments intended for use with neutron beams from reactors. Various types of spectrometers, each devoted to different kinds of measurement can be designed and manufactured, once a prototype having all the attributes of a versatile instrument is designed and developed. With the view to achieving self reliance in this field, Central Workshops of Bhabha Atomic Research Centre (BARC), Bombay designed and developed a prototype of triple axis spectrometer meeting the specifications prepared by Nuclear Physics Division of BARC . This spectrometer, with a moving wedge system was successfully manufactured and installed at 'DHRUVA'. Another version of this spectrometer, called the 'Polarised Neutron Spectrometer' was also built and exported to South Korea and installed at Korea Advanced Energy Research Institute, Seoul. This paper deals with basic concept, development of design, engineering of mechanical assemblies, the manufacturing approach and problems encountered during manufacture. (author). 3 figs

  1. HISS spectrometer

    International Nuclear Information System (INIS)

    Greiner, D.E.

    1984-11-01

    This talk describes the Heavy Ion Spectrometer System (HISS) facility at the Lawrence Berkeley Laboratory's Bevalac. Three completed experiments and their results are illustrated. The second half of the talk is a detailed discussion of the response of drift chambers to heavy ions. The limitations of trajectory measurement over a large range in incident particle charge are presented

  2. The Cognitive Underpinnings of Incremental Rehearsal

    Science.gov (United States)

    Varma, Sashank; Schleisman, Katrina B.

    2014-01-01

    Incremental rehearsal (IR) is a flashcard technique that has been developed and evaluated by school psychologists. We discuss potential learning and memory effects from cognitive psychology that may explain the observed superiority of IR over other flashcard techniques. First, we propose that IR is a form of "spaced practice" that…

  3. Scintillation forward spectrometer of the SPHERE setup

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Afanas'ev, S.V.; Bondarev, V.K.

    1991-01-01

    The construction of the forward spectrometer for the 4π SPHERE setup to study multiple production of particles in nucleus-nucleus interactions is described. The measured parameters of the spectrometer detectors are presented. 7 refs.; 14 figs.; 1 tab

  4. Multiplate ionization total absorption spectrometer with a compressed gas

    International Nuclear Information System (INIS)

    Baskakov, V.I.; Dolgoshein, B.A.; Kantserov, V.A.

    1978-01-01

    The characteristics of a multiplate total absorption spectrometer working with the compressed xenon (up to 25 atm) containing up to 23 radiation lengths of matter are studied. The dependence of the spectrometer energy resolution on the detecting matter density, on the material and thickness of the absorber plates has been studied. The ability of the spectrometer with a tungsten absorber to select hadrons and electrons with P=6 GeV/c by total energy release and characteristics of the cascade longitudinal development has been also studied. The gas spectrometer as it is shown differs quite slightly from the similar spectrometer with liquid argon as for its time resolution it is much better

  5. Mini ion trap mass spectrometer

    Science.gov (United States)

    Dietrich, D.D.; Keville, R.F.

    1995-09-19

    An ion trap is described which operates in the regime between research ion traps which can detect ions with a mass resolution of better than 1:10{sup 9} and commercial mass spectrometers requiring 10{sup 4} ions with resolutions of a few hundred. The power consumption is kept to a minimum by the use of permanent magnets and a novel electron gun design. By Fourier analyzing the ion cyclotron resonance signals induced in the trap electrodes, a complete mass spectra in a single combined structure can be detected. An attribute of the ion trap mass spectrometer is that overall system size is drastically reduced due to combining a unique electron source and mass analyzer/detector in a single device. This enables portable low power mass spectrometers for the detection of environmental pollutants or illicit substances, as well as sensors for on board diagnostics to monitor engine performance or for active feedback in any process involving exhausting waste products. 10 figs.

  6. The Dark Side of Malleability: Incremental Theory Promotes Immoral Behaviors

    OpenAIRE

    Huang, Niwen; Zuo, Shijiang; Wang, Fang; Cai, Pan; Wang, Fengxiang

    2017-01-01

    Implicit theories drastically affect an individual’s processing of social information, decision making, and action. The present research focuses on whether individuals who hold the implicit belief that people’s moral character is fixed (entity theorists) and individuals who hold the implicit belief that people’s moral character is malleable (incremental theorists) make different choices when facing a moral decision. Incremental theorists are less likely to make the fundamental attribution err...

  7. Organization Strategy and Structural Differences for Radical Versus Incremental Innovation

    OpenAIRE

    John E. Ettlie; William P. Bridges; Robert D. O'Keefe

    1984-01-01

    The purpose of this study was to test a model of the organizational innovation process that suggests that the strategy-structure causal sequence is differentiated by radical versus incremental innovation. That is, unique strategy and structure will be required for radical innovation, especially process adoption, while more traditional strategy and structure arrangements tend to support new product introduction and incremental process adoption. This differentiated theory is strongly supported ...

  8. Workshop on high-resolution, large-acceptance spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Zeidman, B. (ed.)

    1981-01-01

    The purpose of the Workshop on High-Resolution, Large-Acceptance Spectrometers was to provide a means for exchange of information among those actively engaged in the design and construction of these new spectrometers. Thirty-seven papers were prepared for the data base.

  9. Incremental deformation: A literature review

    Directory of Open Access Journals (Sweden)

    Nasulea Daniel

    2017-01-01

    Full Text Available Nowadays the customer requirements are in permanent changing and according with them the tendencies in the modern industry is to implement flexible manufacturing processes. In the last decades, metal forming gained attention of the researchers and considerable changes has occurred. Because for a small number of parts, the conventional metal forming processes are expensive and time-consuming in terms of designing and manufacturing preparation, the manufacturers and researchers became interested in flexible processes. One of the most investigated flexible processes in metal forming is incremental sheet forming (ISF. ISF is an advanced flexible manufacturing process which allows to manufacture complex 3D products without expensive dedicated tools. In most of the cases it is needed for an ISF process the following: a simple tool, a fixing device for sheet metal blank and a universal CNC machine. Using this process it can be manufactured axis-symmetric parts, usually using a CNC lathe but also complex asymmetrical parts using CNC milling machines, robots or dedicated equipment. This paper aim to present the current status of incremental sheet forming technologies in terms of process parameters and their influences, wall thickness distribution, springback effect, formability, surface quality and the current main research directions.

  10. Complex Incremental Product Innovation in Established Service Firms: A Micro Institutional Perspective

    NARCIS (Netherlands)

    P.A.M. Vermeulen (Patrick); F.A.J. van den Bosch (Frans); H.W. Volberda (Henk)

    2006-01-01

    textabstractMany product innovation studies have described key determinants that should lead to successful incremental product innovation. Despite numerous studies suggesting how incremental product innovation should be successfully undertaken, many firms still struggle with this type of innovation.

  11. Complex Incremental Product Innovation in Established Service Firms: A Micro Institutional Perspective

    NARCIS (Netherlands)

    P.A.M. Vermeulen (Patrick); F.A.J. van den Bosch (Frans); H.W. Volberda (Henk)

    2007-01-01

    textabstractMany product innovation studies have described key determinants that should lead to successful incremental product innovation. Despite numerous studies suggesting how incremental product innovation should be successfully undertaken, many firms still struggle with this type of innovation.

  12. Polarized neutron spectrometer for inelastic experiments at J-PARC

    Directory of Open Access Journals (Sweden)

    Yokoo Tetsuya

    2015-01-01

    Full Text Available Construction of the newly developed polarization analysis neutron chopper spectrometer (POLANO commenced in the Japan Proton Accelerator Research Complex (J-PARC, Materials and Life Science Experimental Facility (MLF. The POLANO is a direct geometry chopper spectrometer with neutron polarization analysis capability. In the suite of inelastic spectrometers, six instruments are now in operation. POLANO will be the only spectrometer dedicated to polarization analysis experiments. The primary phase of the construction will be completed by 2014 with beam commissioning scheduled for 2015.

  13. The Spectrometer

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2012-01-01

    In the fall of 1999 I was shown an Ocean Optics spectrometer-in-the-computer at St. Patricks College at Maynooth, Ireland, and thought that I had seen heaven. Of course, it could not resolve the sodium D-lines (I had done that many years before with a homemade wire diffraction grating), and I began to realize that inside was some familiar old…

  14. Teraflop-scale Incremental Machine Learning

    OpenAIRE

    Özkural, Eray

    2011-01-01

    We propose a long-term memory design for artificial general intelligence based on Solomonoff's incremental machine learning methods. We use R5RS Scheme and its standard library with a few omissions as the reference machine. We introduce a Levin Search variant based on Stochastic Context Free Grammar together with four synergistic update algorithms that use the same grammar as a guiding probability distribution of programs. The update algorithms include adjusting production probabilities, re-u...

  15. The MIRI Medium Resolution Spectrometer calibration pipeline

    NARCIS (Netherlands)

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-01-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments,

  16. Environmental monitoring systems: a new type of mobile laboratory

    International Nuclear Information System (INIS)

    Bruecher, L.; Langmueller, G.; Tuerschmann, G.

    1999-01-01

    Nuclear facilities are obligated to monitor the environmental radiation in their vicinity, which is often fulfilled by monitoring cars, combined with fixed monitoring stations. The MOLAR Mobile Laboratory for Environmental Radiation Monitoring as described here is being used under normal and accident conditions as a spot check monitoring system or to perform continuous measurements along a driving track. The mobile laboratories are continuously connected with the control centre's CRCS Central Radiological Computer System, where the RIS Radiological Information System provides corresponding evaluation functions. The mobile labs contain measuring and controlling units like γ-dose rate monitors, γ-spectrometer with a HpGe High Purity Germanium detector, a lead shielded measuring cell and MCA Multi-Channel Analyser, portable β-contamination monitor, α/β/γ multipurpose quick measuring unit, aerosol and iodine sampling units. The collected samples are safely stored for the transport to the environmental laboratory for being analysed later. The geographical location of the moving car is continuously determined by the satellite based GPS Global Positioning System and transferred in the on-board rack mounted computer system for being stored and locally displayed. Real-time data transmission via radio and mobile phone is continuously performed to supply the RIS Radiological Information System in the control centre via radio and mobile phone. The latter also serves for voice communication. Currently three MOLAR systems can be operated parallel and independent from the control centre. The system is ready to be extended to more mobile labs. This combination of mobile monitoring, sample analysis and radiological assessment of environmental data in combination with process occurrences has turned out to be a powerful instrument for emergency preparedness and environmental supervising. (orig.) [de

  17. Use of UAV-Borne Spectrometer for Land Cover Classification

    Directory of Open Access Journals (Sweden)

    Sowmya Natesan

    2018-04-01

    Full Text Available Unmanned aerial vehicles (UAV are being used for low altitude remote sensing for thematic land classification using visible light and multi-spectral sensors. The objective of this work was to investigate the use of UAV equipped with a compact spectrometer for land cover classification. The UAV platform used was a DJI Flamewheel F550 hexacopter equipped with GPS and Inertial Measurement Unit (IMU navigation sensors, and a Raspberry Pi processor and camera module. The spectrometer used was the FLAME-NIR, a near-infrared spectrometer for hyperspectral measurements. RGB images and spectrometer data were captured simultaneously. As spectrometer data do not provide continuous terrain coverage, the locations of their ground elliptical footprints were determined from the bundle adjustment solution of the captured images. For each of the spectrometer ground ellipses, the land cover signature at the footprint location was determined to enable the characterization, identification, and classification of land cover elements. To attain a continuous land cover classification map, spatial interpolation was carried out from the irregularly distributed labeled spectrometer points. The accuracy of the classification was assessed using spatial intersection with the object-based image classification performed using the RGB images. Results show that in homogeneous land cover, like water, the accuracy of classification is 78% and in mixed classes, like grass, trees and manmade features, the average accuracy is 50%, thus, indicating the contribution of hyperspectral measurements of low altitude UAV-borne spectrometers to improve land cover classification.

  18. High intensity TOF spectrometer for cold neutrons

    International Nuclear Information System (INIS)

    Maayouf, R.M.; Abd El-Kawy, A.; Habib, N.; Adib, M.; Hamouda, I.

    1984-01-01

    This work presents a neutron time-of-flight (TOF) spectrometer developed specially for total neutron cross-section measurements at neutron energies below 5 MeV and sample's temperature varying from the liquid nitrogen one and up to 500 0 K. The spectrometer is equipped by remote control unit, designed especially, in order to move the sample in and out of the beam during the experimental measurements. The spectrometer has proved to be useful for transmission measurements at neutron energies below 5 MeV. It has a reasonable energy resolution (4.4%) and high effect to background ratio (11.1) at 5 MeV

  19. A Self-Organizing Incremental Neural Network based on local distribution learning.

    Science.gov (United States)

    Xing, Youlu; Shi, Xiaofeng; Shen, Furao; Zhou, Ke; Zhao, Jinxi

    2016-12-01

    In this paper, we propose an unsupervised incremental learning neural network based on local distribution learning, which is called Local Distribution Self-Organizing Incremental Neural Network (LD-SOINN). The LD-SOINN combines the advantages of incremental learning and matrix learning. It can automatically discover suitable nodes to fit the learning data in an incremental way without a priori knowledge such as the structure of the network. The nodes of the network store rich local information regarding the learning data. The adaptive vigilance parameter guarantees that LD-SOINN is able to add new nodes for new knowledge automatically and the number of nodes will not grow unlimitedly. While the learning process continues, nodes that are close to each other and have similar principal components are merged to obtain a concise local representation, which we call a relaxation data representation. A denoising process based on density is designed to reduce the influence of noise. Experiments show that the LD-SOINN performs well on both artificial and real-word data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. The Omega spectrometer

    CERN Multimedia

    1972-01-01

    The Omega spectrometer which came into action during the year. An array of optical spark chambers can be seen withdrawn from the magnet aperture. In the 'igloo' above the magnet is located the Plumbicon camera system which collects information from the spark chambers.

  1. Silicon spectrometer with a Peltier refrigerator

    International Nuclear Information System (INIS)

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  2. Incremental Reconstruction of Urban Environments by Edge-Points Delaunay Triangulation

    OpenAIRE

    Romanoni, Andrea; Matteucci, Matteo

    2016-01-01

    Urban reconstruction from a video captured by a surveying vehicle constitutes a core module of automated mapping. When computational power represents a limited resource and, a detailed map is not the primary goal, the reconstruction can be performed incrementally, from a monocular video, carving a 3D Delaunay triangulation of sparse points; this allows online incremental mapping for tasks such as traversability analysis or obstacle avoidance. To exploit the sharp edges of urban landscape, we ...

  3. Quasi-static incremental behavior of granular materials: Elastic-plastic coupling and micro-scale dissipation

    Science.gov (United States)

    Kuhn, Matthew R.; Daouadji, Ali

    2018-05-01

    The paper addresses a common assumption of elastoplastic modeling: that the recoverable, elastic strain increment is unaffected by alterations of the elastic moduli that accompany loading. This assumption is found to be false for a granular material, and discrete element (DEM) simulations demonstrate that granular materials are coupled materials at both micro- and macro-scales. Elasto-plastic coupling at the macro-scale is placed in the context of thermomechanics framework of Tomasz Hueckel and Hans Ziegler, in which the elastic moduli are altered by irreversible processes during loading. This complex behavior is explored for multi-directional loading probes that follow an initial monotonic loading. An advanced DEM model is used in the study, with non-convex non-spherical particles and two different contact models: a conventional linear-frictional model and an exact implementation of the Hertz-like Cattaneo-Mindlin model. Orthotropic true-triaxial probes were used in the study (i.e., no direct shear strain), with tiny strain increments of 2 ×10-6 . At the micro-scale, contact movements were monitored during small increments of loading and load-reversal, and results show that these movements are not reversed by a reversal of strain direction, and some contacts that were sliding during a loading increment continue to slide during reversal. The probes show that the coupled part of a strain increment, the difference between the recoverable (elastic) increment and its reversible part, must be considered when partitioning strain increments into elastic and plastic parts. Small increments of irreversible (and plastic) strain and contact slipping and frictional dissipation occur for all directions of loading, and an elastic domain, if it exists at all, is smaller than the strain increment used in the simulations.

  4. Development of Neutron Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hee; Lee, J. S.; Seong, B. S. (and others)

    2007-06-15

    Neutron spectrometers which are used in the basic researches such as physics, chemistry and materials science and applied in the industry were developed at the horizontal beam port of HANARO reactor. In addition, the development of core components for neutron scattering and the upgrade of existing facilities are also performed. The vertical neutron reflectometer was fabricated and installed at ST3 beam port. The performance test of the reflectometer was completed and the reflectometer was opened to users. The several core parts and options were added in the polarized neutron spectrometer. The horizontal neutron reflectometer from Brookhaven National Laboratory was moved to HANARO and installed, and the performance of the reflectometer was examined. The HIPD was developed and the performance test was completed. The base shielding for TAS was fabricated. The soller collimator, Cu mosaic monochromator, Si BPC monochromator and position sensitive detector were developed and applied in the neutron spectrometer as part of core component development activities. In addition, the sputtering machine for mirror device are fabricated and the neutron mirror is made using the sputtering machine. The FCD was upgraded and the performance of the FCD are improved over the factor of 10. The integration and upgrade of the neutron detection system were also performed.

  5. ISLA: An Isochronous Spectrometer with Large Acceptances

    Energy Technology Data Exchange (ETDEWEB)

    Bazin, D., E-mail: bazin@nscl.msu.edu; Mittig, W.

    2013-12-15

    A novel type of recoil mass spectrometer and separator is proposed for the future secondary radioactive beams of the ReA12 accelerator at NSCL/FRIB, inspired from the TOFI spectrometer developed at the Los Alamos National Laboratory for online mass measurements. The Isochronous Spectrometer with Large Acceptances (ISLA) is able to achieve superior characteristics without the compromises that usually plague the design of large acceptance spectrometers. ISLA can provide mass-to-charge ratio (m/q) measurements to better than 1 part in 1000 by using an optically isochronous time-of-flight independent of the momentum vector of the recoiling ions, despite large acceptances of 20% in momentum and 64 msr in solid angle. The characteristics of this unique design are shown, including requirements for auxiliary detectors around the target and the various types of reactions to be used with the re-accelerated radioactive beams of the future ReA12 accelerator.

  6. Multichannel Dynamic Fourier-Transform IR Spectrometer

    Science.gov (United States)

    Balashov, A. A.; Vaguine, V. A.; Golyak, Il. S.; Morozov, A. N.; Khorokhorin, A. I.

    2017-09-01

    A design of a multichannel continuous scan Fourier-transform IR spectrometer for simultaneous recording and analysis of the spectral characteristics of several objects is proposed. For implementing the design, a multi-probe fiber is used, constructed from several optical fibers connected into a single optical connector and attached at the output of the interferometer. The Fourier-transform spectrometer is used as a signal modulator. Each fiber is individually mated with an investigated sample and a dedicated radiation detector. For the developed system, the radiation intensity of the spectrometer is calculated from the condition of the minimum spectral resolution and parameters of the optical fibers. Using the proposed design, emission spectra of a gas-discharge neon lamp have been recorded using a single fiber 1 mm in diameter with a numerical aperture NA = 0.22.

  7. The high-resolution time-of-flight spectrometer TOFTOF

    Energy Technology Data Exchange (ETDEWEB)

    Unruh, Tobias [Technische Universitaet Muenchen, Forschungsneutronenquelle Heinz Maier-Leibnitz FRM II and Physik Department E13, Lichtenbergstr. 1, 85747 Garching (Germany)], E-mail: Tobias.Unruh@frm2.tum.de; Neuhaus, Juergen; Petry, Winfried [Technische Universitaet Muenchen, Forschungsneutronenquelle Heinz Maier-Leibnitz FRM II and Physik Department E13, Lichtenbergstr. 1, 85747 Garching (Germany)

    2007-10-11

    The TOFTOF spectrometer is a multi-disc chopper time-of-flight spectrometer for cold neutrons at the research neutron source Heinz Maier-Leibnitz (FRM II). After five reactor cycles of routine operation the characteristics of the instrument are reported in this article. The spectrometer features an excellent signal to background ratio due to its remote position in the neutron guide hall, an elaborated shielding concept and an s-shaped curved primary neutron guide which acts i.a. as a neutron velocity filter. The spectrometer is fed with neutrons from the undermoderated cold neutron source of the FRM II leading to a total neutron flux of {approx}10{sup 10}n/cm{sup 2}/s in the continuous white beam at the sample position distributed over a continuous and particularly broad wavelength spectrum. A high energy resolution is achieved by the use of high speed chopper discs made of carbon-fiber-reinforced plastic. In the combination of intensity, resolution and signal to background ratio the spectrometer offers new scientific prospects in the fields of inelastic and quasielastic neutron scattering.

  8. The high-resolution time-of-flight spectrometer TOFTOF

    Science.gov (United States)

    Unruh, Tobias; Neuhaus, Jürgen; Petry, Winfried

    2007-10-01

    The TOFTOF spectrometer is a multi-disc chopper time-of-flight spectrometer for cold neutrons at the research neutron source Heinz Maier-Leibnitz (FRM II). After five reactor cycles of routine operation the characteristics of the instrument are reported in this article. The spectrometer features an excellent signal to background ratio due to its remote position in the neutron guide hall, an elaborated shielding concept and an s-shaped curved primary neutron guide which acts i.a. as a neutron velocity filter. The spectrometer is fed with neutrons from the undermoderated cold neutron source of the FRM II leading to a total neutron flux of ˜1010n/cm2/s in the continuous white beam at the sample position distributed over a continuous and particularly broad wavelength spectrum. A high energy resolution is achieved by the use of high speed chopper discs made of carbon-fiber-reinforced plastic. In the combination of intensity, resolution and signal to background ratio the spectrometer offers new scientific prospects in the fields of inelastic and quasielastic neutron scattering.

  9. Automatic incrementalization of Prolog based static analyses

    DEFF Research Database (Denmark)

    Eichberg, Michael; Kahl, Matthias; Saha, Diptikalyan

    2007-01-01

    Modem development environments integrate various static analyses into the build process. Analyses that analyze the whole project whenever the project changes are impractical in this context. We present an approach to automatic incrementalization of analyses that are specified as tabled logic prog...

  10. A new recursive incremental algorithm for building minimal acyclic deterministic finite automata

    NARCIS (Netherlands)

    Watson, B.W.; Martin-Vide, C.; Mitrana, V.

    2003-01-01

    This chapter presents a new algorithm for incrementally building minimal acyclic deterministic finite automata. Such minimal automata are a compact representation of a finite set of words (e.g. in a spell checker). The incremental aspect of such algorithms (where the intermediate automaton is

  11. Frequency-Modulation Correlation Spectrometer

    Science.gov (United States)

    Margolis, J. S.; Martonchik, J. V.

    1985-01-01

    New type of correlation spectrometer eliminates need to shift between two cells, one empty and one containing reference gas. Electrooptical phase modulator sinusoidally shift frequencies of sample transmission spectrum.

  12. High intensity line source for x-ray spectrometer calibration

    International Nuclear Information System (INIS)

    Thoe, R.S.

    1986-06-01

    A high intensity electron-impact x-ray source using a one-dimensional Pierce lens has been built for the purpose of calibrating a bent crystal x-ray spectrometer. This source focuses up to 100 mA of 20-keV electrons to a line on a liquid-cooled anode. The line (which can serve as a virtual slit for the spectrometer) measures approximately 800 μ x 2 cm. The source is portable and therefore adaptable to numerous types of spectrometer applications. One particular application, the calibration of a high resolution (r = 10 4 ) time-resolved cyrstal spectrometer, will be discussed in detail

  13. Global Combat Support System - Army Increment 2 (GCSS-A Inc 2)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Global Combat Support System - Army Increment 2 (GCSS-A Inc 2) Defense Acquisition...Secretary of Defense PB - President’s Budget RDT&E - Research, Development, Test, and Evaluation SAE - Service Acquisition Executive TBD - To Be...Date Assigned: Program Information Program Name Global Combat Support System - Army Increment 2 (GCSS-A Inc 2) DoD Component Army Responsible

  14. The balanced scorecard: an incremental approach model to health care management.

    Science.gov (United States)

    Pineno, Charles J

    2002-01-01

    The balanced scorecard represents a technique used in strategic management to translate an organization's mission and strategy into a comprehensive set of performance measures that provide the framework for implementation of strategic management. This article develops an incremental approach for decision making by formulating a specific balanced scorecard model with an index of nonfinancial as well as financial measures. The incremental approach to costs, including profit contribution analysis and probabilities, allows decisionmakers to assess, for example, how their desire to meet different health care needs will cause changes in service design. This incremental approach to the balanced scorecard may prove to be useful in evaluating the existence of causality relationships between different objective and subjective measures to be included within the balanced scorecard.

  15. Ion-neutral transport through quadrupole interfaces of mass-spectrometer systems

    International Nuclear Information System (INIS)

    Jugroot, M.; Groth, C.P.T.; Thomson, B.A.; Baranov, V.; Collings, B.A.; French, J.B.

    2004-01-01

    The transport of free ions through highly under-expanded jet flows of neutral gases and in the presence of applied electric fields is investigated by continuum-based numerical simulations. In particular, numerical results are described which are relevant to ion flows occurring in quadrupole interfaces of mass spectrometer systems. A five-moment mathematical model and parallel multi-block numerical solution procedure is developed for predicting the ion transport. The model incorporates the effects of ion-neutral collision processes and is used in conjunction with a Navier-Stokes model and flow solver for the neutral gas to examine the key influences controlling the ion motion. The effects of the neutral gas flow, electric fields (both dc and rf), and flow field geometry on ion mobility are carefully assessed. The capability of controlling the charged particle motions through a combination of directed neutral flow and applied electric field is demonstrated for these high-speed, hypersonic, jet flows. (author)

  16. Basics of spectroscopic instruments. Hardware of NMR spectrometer

    International Nuclear Information System (INIS)

    Sato, Hajime

    2009-01-01

    NMR is a powerful tool for structure analysis of small molecules, natural products, biological macromolecules, synthesized polymers, samples from material science and so on. Magnetic Resonance Imaging (MRI) is applicable to plants and animals Because most of NMR experiments can be done by an automation mode, one can forget hardware of NMR spectrometers. It would be good to understand features and performance of NMR spectrometers. Here I present hardware of a modern NMR spectrometer which is fully equipped with digital technology. (author)

  17. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  18. Effect of jitter on an imaging FTIR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, C. L., LLNL

    1997-04-01

    Line of sight (LOS) jitter produces temporal modulations of the signals which are detected in the focal plane of a temporally modulated imaging Fourier Transform Spectrometer. A theoretical treatment of LOS jitter effects is given, and is compared with the results of measurements with LIFTIRS1 (the Livermore Imaging Fourier Transform InfraRed Spectrometer). The identification, isolation, quantification and removal of jitter artifacts in hyperspectral imaging data by means of principal components analysis is discussed. The theoretical distribution of eigenvalues expected from principal components analysis is used to determine the level of significance of spatially coherent instrumental artifacts in general, including jitter as a representative example. It is concluded that an imaging FTIR spectrometer is much less seriously impacted by a given LOS jitter level than a non imaging FTIR spectrometer.

  19. Resonant ultrasound spectrometer

    Science.gov (United States)

    Migliori, Albert; Visscher, William M.; Fisk, Zachary

    1990-01-01

    An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.

  20. Volatilities, traded volumes, and the hypothesis of price increments in derivative securities

    Science.gov (United States)

    Lim, Gyuchang; Kim, SooYong; Scalas, Enrico; Kim, Kyungsik

    2007-08-01

    A detrended fluctuation analysis (DFA) is applied to the statistics of Korean treasury bond (KTB) futures from which the logarithmic increments, volatilities, and traded volumes are estimated over a specific time lag. In this study, the logarithmic increment of futures prices has no long-memory property, while the volatility and the traded volume exhibit the existence of the long-memory property. To analyze and calculate whether the volatility clustering is due to a inherent higher-order correlation not detected by with the direct application of the DFA to logarithmic increments of KTB futures, it is of importance to shuffle the original tick data of future prices and to generate a geometric Brownian random walk with the same mean and standard deviation. It was found from a comparison of the three tick data that the higher-order correlation inherent in logarithmic increments leads to volatility clustering. Particularly, the result of the DFA on volatilities and traded volumes can be supported by the hypothesis of price changes.

  1. Wide band ENDOR spectrometer

    International Nuclear Information System (INIS)

    Mendonca Filho, C.

    1973-01-01

    The construction of an ENDOR spectrometer operating from 0,5 to 75 MHz within a single band, with ore Klystron and homodine detection, and no fundamental changes on the electron spin resonance spectrometer was described. The ENDOR signal can be detected both by amplitude modulation of the frequency field, or direct detection of the ESR output, which is taken to a signal analyser. The signal-to-noise ratio is raised by averaging rather than filtering avoiding the use of long time constants, providing natural line widths. The experimental apparatus and the spectra obtained are described. A discussion, relating the ENDOR line amplitudes with the experimental conditions is done and ENDOR mechanism, in which there is a relevant presence of cross relaxation is proposed

  2. Software designs of image processing tasks with incremental refinement of computation.

    Science.gov (United States)

    Anastasia, Davide; Andreopoulos, Yiannis

    2010-08-01

    Software realizations of computationally-demanding image processing tasks (e.g., image transforms and convolution) do not currently provide graceful degradation when their clock-cycles budgets are reduced, e.g., when delay deadlines are imposed in a multitasking environment to meet throughput requirements. This is an important obstacle in the quest for full utilization of modern programmable platforms' capabilities since worst-case considerations must be in place for reasonable quality of results. In this paper, we propose (and make available online) platform-independent software designs performing bitplane-based computation combined with an incremental packing framework in order to realize block transforms, 2-D convolution and frame-by-frame block matching. The proposed framework realizes incremental computation: progressive processing of input-source increments improves the output quality monotonically. Comparisons with the equivalent nonincremental software realization of each algorithm reveal that, for the same precision of the result, the proposed approach can lead to comparable or faster execution, while it can be arbitrarily terminated and provide the result up to the computed precision. Application examples with region-of-interest based incremental computation, task scheduling per frame, and energy-distortion scalability verify that our proposal provides significant performance scalability with graceful degradation.

  3. FIR and sub-mm direct detection spectrometers for spaceborne astronomy

    Science.gov (United States)

    Wijnbergen, Jan J.; de Graauw, Thijs

    1990-12-01

    Candidate spaceborne sub-mm instrumentation proposed for space projects with large passively cooled telescopes are reviewed. Grating instruments and Fourier transform spectroscopy (FTS) spectrometers are discussed. Particular attention is given to imaging Fabry-Perot spectrometers. The special needs of the Large Deployable Reflector (LDR) and for the Far InfraRed Space Telescope (FIRST) missions in this area are outlined. Possible Fabry-Perot spectrometer setups are diagrammed and outlined. The use of spherical and multiplex Fabry-Perot spectrometers is discussed.

  4. Micro faraday-element array detector for ion mobility spectroscopy

    Science.gov (United States)

    Gresham, Christopher A [Albuquerque, NM; Rodacy, Phillip J [Albuquerque, NM; Denton, M Bonner [Tucson, AZ; Sperline, Roger [Tucson, AZ

    2004-10-26

    An ion mobility spectrometer includes a drift tube having a collecting surface covering a collecting area at one end of the tube. The surface comprises a plurality of closely spaced conductive elements on a non-conductive substrate, each conductive element being electrically insulated from each other element. A plurality of capacitive transimpedance amplifiers (CTIA) adjacent the collecting surface are electrically connected to the plurality of elements, so charge from an ion striking an element is transferred to the capacitor of the connected CTIA. A controller counts the charge on the capacitors over a period of time.

  5. Liquid scintillation spectrometer survey 155Eu liquid activity

    International Nuclear Information System (INIS)

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  6. PERFORMANCE ANALYSIS OF AI BASED QOS SCHEDULER FOR MOBILE WIMAX

    Directory of Open Access Journals (Sweden)

    D. David Neels Pon Kumar

    2012-09-01

    Full Text Available Interest in broadband wireless access (BWA has been growing due to increased user mobility and the need for data access at all times. IEEE 802.16e based WiMAX networks promise the best available quality of experience for mobile data service users. WiMAX networks incorporate several Quality of Service (QoS mechanisms at the Media Access Control (MAC level for guaranteed services for multimedia viz. data, voice and video. The problem of assuring QoS is how to allocate available resources among users to meet the QoS criteria such as delay, delay jitter, fairness and throughput requirements. IEEE standard does not include a standard scheduling mechanism and leaves it for various implementer differentiations. Although a lot of the real-time and non real-time packet scheduling schemes has been proposed, it needs to be modified to apply to Mobile WiMAX system that supports five kinds of service classes. In this paper, we propose a novel Priority based Scheduling scheme that uses Artificial Intelligence to support various services by considering the QoS constraints of each class. The simulation results show that slow mobility does not affect the performances and faster mobility and the increment in users beyond a particular load have their say in defining average throughput, average per user throughput, fairness index, average end to end delay and average delay jitter. Nevertheless the results are encouraging that the proposed scheme provides QoS support for each class efficiently.

  7. Forward spectrometers at the SSC

    International Nuclear Information System (INIS)

    Bjorken, J.D.

    1986-01-01

    Most of SSC phase space and a great deal of physics potential is in the forward/backward region (absolute value of theta < 100 mrad). Comprehensive open-geometry spectrometers are feasible and very cost effective. Examples of such devices are sketched. Because such spectrometers are very long and may operate at high β and longer bunch spacing, they impact now on SSC interaction - region design. The data acquisition load is as heavy as for central detectors, although there may be less emphasis on speed and more emphasis on sophisticated parallel and/or distributed processing for event selection, as well as on high-capacity buffering

  8. The role of ion optics modeling in the design and development of ion mobility spectrometers

    Science.gov (United States)

    Griffin, Matthew T.

    2005-05-01

    Detection of trace gases by ion mobility spectroscopy (IMS) has become common in recent years. In fact, IMS devices are the most commonly deployed military devices for the detection of classical chemical warfare agents (CWA). IMS devices are protecting the homeland by aiding first responders in the identification of toxic industrial chemicals (TICs) and providing explosive and narcotic screening systems. Spurred by the asymmetric threat posed by new threat agents and the ever expanding list of toxic chemicals, research in the development, improvement, and optimization of IMS systems has increased. Much of the research is focused on increasing the sensitivity and selectivity of IMS systems. Ion optics is a large area of study in the field of mass spectrometry, but has been mostly overlooked in the design and development of IMS systems. Ion optics provides insight into particle trajectories, duty cycle, and efficiency of these systems. This paper will outline the role that ion optics can have in the development of IMS systems and introduce the trade space for traditional IMS as well as differential mobility spectroscopy.

  9. Triple axis spectrometers

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1997-01-01

    Conventional triple-axis neutron spectroscopy was developed by Brockhouse over thirty years ago' and remains today a versatile and powerful tool for probing the dynamics of condensed matter. The original design of the triple axis spectrometer is technically simple and probes momentum and energy space on a point-by-point basis. This ability to systematically probe the scattering function in a way which only requires a few angles to be moved under computer control and where the observed data in general can be analysed using a pencil and graph paper or a simple fitting routine, has been essential for the success of the method. These constraints were quite reasonable at the time the technique was developed. Advances in computer based data acquisition, neutron beam optics, and position sensitive area detectors have been gradually implemented on many triple axis spectrometer spectrometers, but the full potential of this has not been fully exploited yet. Further improvement in terms of efficiency (beyond point by point inspection) and increased sensitivity (use of focusing optics whenever the problem allows it) could easily be up to a factor of 10-20 over present instruments for many problems at a cost which is negligible compared to that of increasing the flux of the source. The real cost will be in complexity - finding the optimal set-up for a given scan and interpreting the data as the they are taken. On-line transformation of the data for an appropriate display in Q, ω space and analysis tools will be equally important for this task, and the success of these new ideas will crucially depend on how well we solve these problems. (author)

  10. Evidence combination for incremental decision-making processes

    NARCIS (Netherlands)

    Berrada, Ghita; van Keulen, Maurice; de Keijzer, Ander

    The establishment of a medical diagnosis is an incremental process highly fraught with uncertainty. At each step of this painstaking process, it may be beneficial to be able to quantify the uncertainty linked to the diagnosis and steadily update the uncertainty estimation using available sources of

  11. Incremental Nonnegative Matrix Factorization for Face Recognition

    Directory of Open Access Journals (Sweden)

    Wen-Sheng Chen

    2008-01-01

    Full Text Available Nonnegative matrix factorization (NMF is a promising approach for local feature extraction in face recognition tasks. However, there are two major drawbacks in almost all existing NMF-based methods. One shortcoming is that the computational cost is expensive for large matrix decomposition. The other is that it must conduct repetitive learning, when the training samples or classes are updated. To overcome these two limitations, this paper proposes a novel incremental nonnegative matrix factorization (INMF for face representation and recognition. The proposed INMF approach is based on a novel constraint criterion and our previous block strategy. It thus has some good properties, such as low computational complexity, sparse coefficient matrix. Also, the coefficient column vectors between different classes are orthogonal. In particular, it can be applied to incremental learning. Two face databases, namely FERET and CMU PIE face databases, are selected for evaluation. Compared with PCA and some state-of-the-art NMF-based methods, our INMF approach gives the best performance.

  12. Adaptive Tunable Laser Spectrometer for Space Applications

    Science.gov (United States)

    Flesch, Gregory; Keymeulen, Didier

    2010-01-01

    An architecture and process for the rapid prototyping and subsequent development of an adaptive tunable laser absorption spectrometer (TLS) are described. Our digital hardware/firmware/software platform is both reconfigurable at design time as well as autonomously adaptive in real-time for both post-integration and post-launch situations. The design expands the range of viable target environments and enhances tunable laser spectrometer performance in extreme and even unpredictable environments. Through rapid prototyping with a commercial RTOS/FPGA platform, we have implemented a fully operational tunable laser spectrometer (using a highly sensitive second harmonic technique). With this prototype, we have demonstrated autonomous real-time adaptivity in the lab with simulated extreme environments.

  13. Calibration techniques for a fast duo-spectrometer

    International Nuclear Information System (INIS)

    Chapman, J.T.; Den Hartog, D.J.

    1996-06-01

    The authors have completed the upgrade and calibration of the Ion Dynamics Spectrometer (IDS), a high-speed Doppler duo-spectrometer which measures ion flow and temperature in the MST Reversed-field Pinch. This paper describes an in situ calibration of the diagnostic's phase and frequency response. A single clock was employed to generate both a digital test signal and a digitizer trigger thus avoiding frequency drift and providing a highly resolved measurement over the system bandwidth. Additionally, they review the measurement of the spectrometer instrument function and absolute intensity response. This calibration and subsequent performance demonstrate the IDS to be one of the fastest, highest throughput diagnostics of its kind. Typical measurements are presented

  14. A compact multichannel spectrometer for Thomson scatteringa)

    Science.gov (United States)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  15. A compact multichannel spectrometer for Thomson scattering

    International Nuclear Information System (INIS)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-01-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T e e > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (∼2 ns) ICCD camera for detection. A Gen III image intensifier provides ∼45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  16. A compact multichannel spectrometer for Thomson scattering.

    Science.gov (United States)

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  17. A GPU-Based Wide-Band Radio Spectrometer

    Science.gov (United States)

    Chennamangalam, Jayanth; Scott, Simon; Jones, Glenn; Chen, Hong; Ford, John; Kepley, Amanda; Lorimer, D. R.; Nie, Jun; Prestage, Richard; Roshi, D. Anish; Wagner, Mark; Werthimer, Dan

    2014-12-01

    The graphics processing unit has become an integral part of astronomical instrumentation, enabling high-performance online data reduction and accelerated online signal processing. In this paper, we describe a wide-band reconfigurable spectrometer built using an off-the-shelf graphics processing unit card. This spectrometer, when configured as a polyphase filter bank, supports a dual-polarisation bandwidth of up to 1.1 GHz (or a single-polarisation bandwidth of up to 2.2 GHz) on the latest generation of graphics processing units. On the other hand, when configured as a direct fast Fourier transform, the spectrometer supports a dual-polarisation bandwidth of up to 1.4 GHz (or a single-polarisation bandwidth of up to 2.8 GHz).

  18. Tandem ion mobility spectrometry coupled to laser excitation

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Anne-Laure; Choi, Chang Min; Clavier, Christian; Barbaire, Marc; Maurelli, Jacques; Dagany, Xavier; MacAleese, Luke; Dugourd, Philippe, E-mail: philippe.dugourd@univ-lyon1.fr [Institut Lumière Matière, Université de Lyon, Université Lyon 1-CNRS, 69622 Villeurbanne cedex (France); Chirot, Fabien [Institut des Sciences Analytiques, Université de Lyon, Université Lyon 1-CNRS, 69622 Villeurbanne cedex (France)

    2015-09-15

    This manuscript describes a new experimental setup that allows to perform tandem ion mobility spectrometry (IMS) measurements and which is coupled to a high resolution time-of-flight mass spectrometer. It consists of two 79 cm long drift tubes connected by a dual ion funnel assembly. The setup was built to permit laser irradiation of the ions in the transfer region between the two drift tubes. This geometry allows selecting ions according to their ion mobility in the first drift tube, to irradiate selected ions, and examine the ion mobility of the product ions in the second drift tube. Activation by collision is possible in the same region (between the two tubes) and between the second tube and the time-of-flight. IMS-IMS experiments on Ubiquitin are reported. We selected a given isomer of charge state +7 and explored its structural rearrangement following collisional activation between the two drift tubes. An example of IMS-laser-IMS experiment is reported on eosin Y, where laser irradiation was used to produce radical ions by electron photodetachment starting from doubly deprotonated species. This allowed measuring the collision cross section of the radical photo-product, which cannot be directly produced with an electrospray source.

  19. SWIFTS: on-chip very high spectral resolution spectrometer

    Science.gov (United States)

    le Coarer, E.; Venancio, L. G.; Kern, P.; Ferrand, J.; Puget, P.; Ayraud, M.; Bonneville, C.; Demonte, B.; Morand, A.; Boussey, J.; Barbier, D.; Blaize, S.; Gonthiez, T.

    2017-11-01

    The size and the weight of state of the art spectrometers is a serious issue regarding space applications. SWIFTS (Stationary Wave Integrated Fourier Transform Spectrometer) is a new FTS family without any moving part. This very promising technology is an original way to fully sample the Fourier interferogram obtained in a waveguide by either a reflection (SWIFTS Lippmann) or counter-propagative (SWIFTS Gabor) interference phenomenon. The sampling is simultaneously performed the optical path thanks to "nano-detectors" located in the evanescent field of the waveguide. For instance a 1.7cm long waveguide properly associated to the detector achieves directly a resolution of 0.13cm-1 on a few centimetre long instruments. Here, firstly we present the development status of this new kind of spectrometers and the first results obtained with on going development of spectrometer covering simultaneously the visible domain from 400 to 1000 nm like an Echelle spectrometer. Valuable technologies allows one to extend the concept to various wavelength domains. Secondly, we present the results obtained in the frame of an activity funded by the European Space Agency where several potential applications in space missions have been identified and studied.

  20. FERDO/FERD, Unfolding of Pulse-Height Spectrometer Spectra

    International Nuclear Information System (INIS)

    Rust, B.W.; Ingersoll, D.T.; Burrus, W.R.

    1985-01-01

    1 - Description of problem or function: FERDO and FERD are unfolding codes which can be used to correct observed pulse-height distributions for the non-ideal response of a pulse-height spectrometer or to solve poorly conditioned linear equations. 2 - Method of solution: It is assumed that the response of the spectrometer is given by Ax = b, where A is the spectrometer response function matrix, x is the unknown spectrum, and b is the pulse-height distribution. FERDO does not resolve directly for x but instead solves for p = Wx, where W is a 'window function matrix'. Typically, W is the resolution function of an ideal spectrometer which has a single Gaussian response. The effective resolution of the unfolding solution may be varied by the choice of W. Confidence intervals are found for each element of the solution p

  1. Apparatus for electrical-assisted incremental forming and process thereof

    Science.gov (United States)

    Roth, John; Cao, Jian

    2018-04-24

    A process and apparatus for forming a sheet metal component using an electric current passing through the component. The process can include providing an incremental forming machine, the machine having at least one arcuate tipped tool and at least electrode spaced a predetermined distance from the arcuate tipped tool. The machine is operable to perform a plurality of incremental deformations on the sheet metal component using the arcuate tipped tool. The machine is also operable to apply an electric direct current through the electrode into the sheet metal component at the predetermined distance from the arcuate tipped tool while the machine is forming the sheet metal component.

  2. A NMR spectrometer for educational purposes; Espectrometro de RMN para ensino

    Energy Technology Data Exchange (ETDEWEB)

    Colnago, Luiz A; Torre Neto, Andre [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Nucleo de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria; Villar, Jose D.F.; Seidl, Peter R [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil)

    1992-12-31

    A NMR spectrometer has been constructed for educational purposes, such as teaching of the technique basic principles and instrumentation. The spectrometer has been designed with a minimum number of components so that the students may have acquittance with both the spectrometer, through block diagrams, and the small numbers of existent components . The device was based on a 0.t Tesla magnet from the continuous wave spectrometer (E M 300 - Varian) existent at the Instituto Militar de Engenharia, and it is expected to facilitate the comprehension of the commercial spectrometers 1 ref., 3 figs.

  3. GammaLog Playback 1.0 - mobile gamma ray spectrometry software

    International Nuclear Information System (INIS)

    Watson, R.J.; Smethurst, M.A.

    2011-01-01

    The Geological Survey of Norway (NGU) operates a mobile gamma ray spectrometer system which can be used in nuclear emergency situations to determine the location and type of orphan sources, or the extent and type of fallout contamination. The system consists of a 20 litre (16 litre downward and 4 litre upward looking) RSX-5 NaI detector and spectrometer, and can be mounted in fixed wing aircraft, helicopters, or vans/cars as appropriate. NGU has developed its own data acquisition and analysis software for this system. GammaLog (Smethurst 2005) controls the acquisition, display, and storage of data from the spectrometer, and performs real-time data analysis including estimation of dose rates and fallout concentrations, and separation of geological and anthropogenic components of the signal. The latter is particularly important where the geological radioisotope signal varies strongly from one place to another, and makes it easier to locate and identify anthropogenic sources which might otherwise be difficult to separate from the geological background signal. A modified version of GammaLog has been developed, GammaLog Playback, which allows the replay of previously acquired GammaLog datasets, while performing similar processing and display as the GammaLog acquisition software. This allows datasets to be reviewed and compared in the field or during post-survey analysis to help plan subsequent measurement strategies.(Au)

  4. Existing School Buildings: Incremental Seismic Retrofit Opportunities.

    Science.gov (United States)

    Federal Emergency Management Agency, Washington, DC.

    The intent of this document is to provide technical guidance to school district facility managers for linking specific incremental seismic retrofit opportunities to specific maintenance and capital improvement projects. The linkages are based on logical affinities, such as technical fit, location of the work within the building, cost saving…

  5. MAGNETIC SPECTROMETER DESIGN FOR ELECTRON SCATTERING ABOVE 1 Bev

    Energy Technology Data Exchange (ETDEWEB)

    Schopper, H.

    1963-06-15

    Design considerations are discussed for magnetic spectrometer electron scattering investigations with the higher energy (above 1 Bev) electron sources which are being developed. The spectrometers are to be used to discriminate between elastic and inelastic processes. A momentum resolution of the order of one per cent is required for these experiments. Various spectrometers are compared according to their optical properties and the number of magnets they consist of. (R.E.U.)

  6. Echelle grating multi-order imaging spectrometer utilizing a catadioptric lens

    Science.gov (United States)

    Chrisp, Michael P; Bowers, Joel M

    2014-05-27

    A cryogenically cooled imaging spectrometer that includes a spectrometer housing having a first side and a second side opposite the first side. An entrance slit is on the first side of the spectrometer housing and directs light to a cross-disperser grating. An echelle immersions grating and a catadioptric lens are positioned in the housing to receive the light. A cryogenically cooled detector is located in the housing on the second side of the spectrometer housing. Light from the entrance slit is directed to the cross-disperser grating. The light is directed from the cross-disperser grating to the echelle immersions grating. The light is directed from the echelle immersions grating to the cryogenically cooled detector on the second side of the spectrometer housing.

  7. Field Observation of the Green Ocean Amazon. Neutral Cluster Air Ion Spectrometer (NAIS) Final Campaign Summary

    Energy Technology Data Exchange (ETDEWEB)

    Petaja, T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Backman, J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manninen, H. E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wimmer, D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-01

    The neutral cluster and air ion spectrometer (NAIS) was deployed to the T3 site for Intensive Operations Periods 1 and 2 (IOP1 and IOP2). The NAIS is an instrument that measures aerosol particle and ion number size distributions in the mobility diameter range of 0.8 to 42 nm, corresponding to electrical mobility range between 3.2 and 0.0013 cm2 V-1 s-1. New particle formation (NPF) events were detected using the NAIS at the T3 field site during IOP1 and IOP2. Secondary NPF is a globally important source of aerosol number. To fully explain atmospheric NPF and subsequent growth, we need to directly measure the initial steps of the formation processes in different environments, including rain forest. Particle formation characteristics, such as formation and growth rates, were used as indicators of the relevant processes and participating compounds in the initial formation. In a case of parallel ion and neutral cluster measurements, we estimated the relative contribution of ion-induced and neutral nucleation to the total particle formation.

  8. Miniature Neutron-Alpha Activation Spectrometer

    Science.gov (United States)

    Rhodes, E.; Goldsten, J.

    2001-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in situ analysis of samples including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform, that would meet the severe mass, power, and environmental constraints of missions to the outer planets. In the neutron-activation mode, a gamma-ray spectrometer will first perform a penetrating scan of soil, ice, and loose material underfoot (depths to 10 cm or more) to identify appropriate samples. Chosen samples will be analyzed in bulk in neutron-activation mode, and then the sample surfaces will be analyzed in alpha-activation mode using Rutherford backscatter and x-ray spectrometers. The instrument will provide sample composition over a wide range of elements, including rock-forming elements (such as Na, Mg, Si, Fe, and Ca), rare earths (Sm and Eu for example), radioactive elements (K, Th, and U), and light elements present in water, ices, and biological materials (mainly H, C, O, and N). The instrument is expected to have a mass of about l kg and to require less than 1 W power. Additional information is contained in the original extended abstract.

  9. VERITAS: Versatile Triple-Axis Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Il

    2006-04-15

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, {approx} 5 m Curved Guide, {approx} 26 m w/ R 1500 m Straight Guide before the Instrument, {approx} 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world.

  10. VERITAS: Versatile Triple-Axis Spectrometer

    International Nuclear Information System (INIS)

    Park, Sung Il

    2006-04-01

    Korea Atomic Energy Research Institute is planning to build a cold neutron triple-axis spectrometer at HANARO, the 30 MW research reactor. The spectrometer is expected to be completed in 2008 with the following configuration from the upstream to the downstream. Guide Supermirror m = 2, In-pile Straight Section, ∼ 5 m Curved Guide, ∼ 26 m w/ R 1500 m Straight Guide before the Instrument, ∼ 40 m Filters PG and Be Neutron Velocity Selector (Future) Monochromators Vertically Focusing Monochromators PG(002) and Heusler(111) Doubly Focusing Monochromators (Future) Monochromator-Sample Distance 2 m Collimation C1 Soller Collimators, 20', 40' 80'Beam Height at the Sample Table 1.5 m Sample-Analyzer Distance 1.0 m Collimation C2 Soller Collimators, 20', 40', 80' Radial Collimator Analyzers Horizontally Focusing Analyzers w/ Fixed Vertical Focusing PG(002) and Heusler(111) Analyzer-Detector Distance 0.5 m Detectors 5 cm Tube Detector 25 cm wide Position Sensitive Detector Once completed, the neutron flux at sample is expected to surpass that of SPINS at NCNR, making this instrument one of the most powerful 2nd generation cold neutron triple-axis spectrometers in the world

  11. Theory and optical design of x-ray echo spectrometers

    Science.gov (United States)

    Shvyd'ko, Yuri

    2017-08-01

    X-ray echo spectroscopy, a space-domain counterpart of neutron spin echo, is a recently proposed inelastic x-ray scattering (IXS) technique. X-ray echo spectroscopy relies on imaging IXS spectra and does not require x-ray monochromatization. Due to this, the echo-type IXS spectrometers are broadband, and thus have a potential to simultaneously provide dramatically increased signal strength, reduced measurement times, and higher resolution compared to the traditional narrow-band scanning-type IXS spectrometers. The theory of x-ray echo spectrometers presented earlier [Yu. Shvyd'ko, Phys. Rev. Lett. 116, 080801 (2016), 10.1103/PhysRevLett.116.080801] is developed here further with a focus on questions of practical importance, which could facilitate optical design and assessment of the feasibility and performance of the echo spectrometers. Among others, the following questions are addressed: spectral resolution, refocusing condition, echo spectrometer tolerances, refocusing condition adjustment, effective beam size on the sample, spectral window of imaging and scanning range, impact of the secondary source size on the spectral resolution, angular dispersive optics, focusing and collimating optics, and detector's spatial resolution. Examples of optical designs and characteristics of echo spectrometers with 1-meV and 0.1-meV resolutions are presented.

  12. Standalone vertex finding in the ATLAS muon spectrometer

    DEFF Research Database (Denmark)

    Aad, A.; Abajyan, T.; Abbott, B.

    2014-01-01

    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The perf......A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths....... The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011....

  13. Electron-ion-x-ray spectrometer system

    International Nuclear Information System (INIS)

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.

    1993-01-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays

  14. Demonstration/Validation of Incremental Sampling at Two Diverse Military Ranges and Development of an Incremental Sampling Tool

    Science.gov (United States)

    2010-06-01

    Sampling (MIS)? • Technique of combining many increments of soil from a number of points within exposure area • Developed by Enviro Stat (Trademarked...Demonstrating a reliable soil sampling strategy to accurately characterize contaminant concentrations in spatially extreme and heterogeneous...into a set of decision (exposure) units • One or several discrete or small- scale composite soil samples collected to represent each decision unit

  15. Ethical leadership: meta-analytic evidence of criterion-related and incremental validity.

    Science.gov (United States)

    Ng, Thomas W H; Feldman, Daniel C

    2015-05-01

    This study examines the criterion-related and incremental validity of ethical leadership (EL) with meta-analytic data. Across 101 samples published over the last 15 years (N = 29,620), we observed that EL demonstrated acceptable criterion-related validity with variables that tap followers' job attitudes, job performance, and evaluations of their leaders. Further, followers' trust in the leader mediated the relationships of EL with job attitudes and performance. In terms of incremental validity, we found that EL significantly, albeit weakly in some cases, predicted task performance, citizenship behavior, and counterproductive work behavior-even after controlling for the effects of such variables as transformational leadership, use of contingent rewards, management by exception, interactional fairness, and destructive leadership. The article concludes with a discussion of ways to strengthen the incremental validity of EL. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  16. Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface

    International Nuclear Information System (INIS)

    Randall, L.G.; Wahrhaftig, A.L.

    1981-01-01

    A detecting mass spectrometer has been successfully coupled to a dense gas (supercritical fluid) chromatograph to produce an instrument (DGC/MS) that may be an alternative to high performance liquid chromatograph/mass spectrometer instruments (HPLC/MS) and gas chromatograph/mass spectrometer instruments (GC/MS) for analysis of involatile and/or thermally labile compounds. The mobile phase in DGC is a gas held at temperatures above the critical temperature and at pressures sufficient to obtain nearly liquid-like densities. DGC combines advantages of GC and HPLC: rapid separations, moderate operating temperatures, and analysis of involatile compounds. An advantage unique to DGC is the solvent power dependence upon pressure. While several groups have studied DGC, its development has been limited by the lack of a sensitive and selective detector. Hence, work has been directed towards the design and construction of a DGC/MS resulting in a trial instrument capable of chromatographic pressures of at least 300 atm and temperatures from 10 0 to 60 0 C. The DGC/MS coupling has been accomplished by the use of a supersonic molecular beam interface. This application of molecular beam formation appears to be unique in its requirements of a large pressure ratio (approx.10 8 ), low flow rates, and low final pressures. The authors outline characteristics of supersonic jets and molecular beams pertinent to the design of such an instrument. The interface which uses pumping speeds of 2400 and 1200 l/s in the beam forming chambers is described in detail, while the other components: the detecting mass spectrometer, the dense gas supply, and the DGC: are briefly described. Preliminary work with this instrument has established the feasibility of DGC/MS as an analytical technique and further development is recommended

  17. Electronic THz-spectrometer for plasmonic enhanced deep subwavelength layer detection

    NARCIS (Netherlands)

    Berrier, A.; Schaafsma, M.C.; Gómez Rivas, J.; Schäfer-Eberwein, H.; Haring Bolivar, P.; Tripodi, L.; Matters-Kammerer, M.K.

    2015-01-01

    We demonstrate the operation of a miniaturized all-electronic CMOS based THz spectrometer with performances comparable to that of a THz-TDS spectrometer in the frequency range 20 to 220 GHz. The use of this all-electronic THz spectrometer for detection of a thin TiO2 layer and a B. subtilis bacteria

  18. Design of a miniaturized integrated spectrometer for spectral tissue sensing

    Science.gov (United States)

    Belay, Gebirie Yizengaw; Hoving, Willem; Ottevaere, Heidi; van der Put, Arthur; Weltjens, Wim; Thienpont, Hugo

    2016-04-01

    Minimally-invasive image-guided procedures become increasingly used by physicians to obtain real-time characterization feedback from the tissue at the tip of their interventional device (needle, catheter, endoscopic or laparoscopic probes, etc…) which can significantly improve the outcome of diagnosis and treatment, and ultimately reduce cost of the medical treatment. Spectral tissue sensing using compact photonic probes has the potential to be a valuable tool for screening and diagnostic purposes, e.g. for discriminating between healthy and tumorous tissue. However, this technique requires a low-cost broadband miniature spectrometer so that it is commercially viable for screening at point-of-care locations such as physicians' offices and outpatient centers. Our goal is therefore to develop a miniaturized spectrometer based on diffractive optics that combines the functionalities of a visible/near-infrared (VIS/NIR) and shortwave-infrared (SWIR) spectrometer in one very compact housing. A second goal is that the hardware can be produced in high volume at low cost without expensive time consuming alignment and calibration steps. We have designed a miniaturized spectrometer which operates both in the visible/near-infrared and shortwave-infrared wavelength regions ranging from 400 nm to 1700 nm. The visible/near-infrared part of the spectrometer is designed for wavelengths from 400 nm to 800 nm whereas the shortwave-infrared segment ranges from 850 nm to 1700 nm. The spectrometer has a resolution of 6 nm in the visible/near-infrared wavelength region and 10 nm in the shortwave-infrared. The minimum SNR of the spectrometer for the intended application is about 151 in the VIS/NIR range and 6000 for SWIR. In this paper, the modelling and design, and power budget analysis of the miniaturized spectrometer are presented. Our work opens a door for future affordable micro- spectrometers which can be integrated with smartphones and tablets, and used for point

  19. Feasibility study of a SiC sandwich neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jian, E-mail: caepwujian@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Lei, Jiarong, E-mail: jiarong_lei@163.com [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Jiang, Yong; Chen, Yu; Rong, Ru; Zou, Dehui; Fan, Xiaoqiang [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, Sichuan Province (China); Chen, Gang; Li, Li; Bai, Song [Nanjing Electronic Devices Institute, Nanjing 210016 (China)

    2013-04-21

    Semiconductor sandwich neutron spectrometers are suitable for in-pile measurements of fast reactor spectra thanks to their compact and relatively simple design. We have assembled and tested a sandwich neutron spectrometer based on 4H-silicon carbide (4H-SiC) Schottky diodes. The SiC diodes detect neutrons via neutron-induced charged particles (tritons and alpha particles) produced by {sup 6}Li(n,α){sup 3}H reaction. {sup 6}LiF neutron converter layers are deposited on the front surface of Schottky diodes by magnetron sputtering. The responses of SiC diodes to charged particles were investigated with an {sup 241}Am alpha source. A sandwich neutron spectrometer was assembled with two SiC Schottky diodes selected based on the charged-particle-response experimental results. The low-energy neutron response of the sandwich spectrometer was measured in the neutron field of the Chinese Fast Burst Reactor-II (CFBR-II). Spectra of alpha particles and tritons from {sup 6}Li(n,α){sup 3}H reaction were obtained with two well-resolved peaks. The energy resolution of the sum spectrum was 8.8%. The primary experimental results confirmed the 4H-SiC sandwich neutron spectrometer's feasibility. -- Highlights: ► Sandwich neutron spectrometer employing 4H-SiC as a detecting material has been developed for the first time. ► {sup 6}LiF neutron converter has been deposited on the surface of 4H-SiC Schottky diode. ► Preliminary testing results obtained with the 4H-SiC sandwich neutron spectrometer are presented.

  20. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    DEFF Research Database (Denmark)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each...

  1. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Groitl, Felix, E-mail: felix.groitl@psi.ch [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bartkowiak, Marek [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bergmann, Ryan M. [Division Large Research Facilities, Paul Scherrer Institut, 5232 Villigen (Switzerland); Birk, Jonas Okkels [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Physics, Technical University of Denmark (DTU), 2800 Kgs. Lyngby (Denmark); Markó, Márton [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Wigner Research Centre for Physics, Neutron Spectroscopy Department, 1525 Budapest (Hungary); Bollhalder, Alex; Graf, Dieter [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Niedermayer, Christof [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Rüegg, Christian [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Quantum Matter Physics, University of Geneva, 1211 Geneva (Switzerland); Rønnow, Henrik M. [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark)

    2017-06-21

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  2. Design and Test of Portable Hyperspectral Imaging Spectrometer

    Directory of Open Access Journals (Sweden)

    Chunbo Zou

    2017-01-01

    Full Text Available We design and implement a portable hyperspectral imaging spectrometer, which has high spectral resolution, high spatial resolution, small volume, and low weight. The flight test has been conducted, and the hyperspectral images are acquired successfully. To achieve high performance, small volume, and regular appearance, an improved Dyson structure is designed and used in the hyperspectral imaging spectrometer. The hyperspectral imaging spectrometer is suitable for the small platform such as CubeSat and UAV (unmanned aerial vehicle, and it is also convenient to use for hyperspectral imaging acquiring in the laboratory and the field.

  3. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    International Nuclear Information System (INIS)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.; Birk, Jonas Okkels; Markó, Márton; Bollhalder, Alex; Graf, Dieter; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  4. Demarcating Mobile Phone Interface Design Guidelines to Expedite Selection

    Directory of Open Access Journals (Sweden)

    Karen Vera Renaud

    2017-12-01

    Full Text Available Guidelines are recommended as a tool for informing user interface design. Despite a proliferation of guidelines in the research literature, there is little evidence of their use in industry, nor their influence in academic literature. In this paper, we explore the research literature related to mobile phone design guidelines to find out why this should be so. We commenced by carrying out a scoping literature review of the mobile phone design guideline literature to gain insight into the maturity of the field. The question we wanted to explore was: “Are researchers building on each others’ guidelines, or is the research field still in the foundational stage?” We discovered a poorly structured field, with many researchers proposing new guidelines, but little incremental refinement of extant guidelines. It also became clear that the current reporting of guidelines did not explicitly communicate their multi-dimensionality or deployment context. This leaves designers without a clear way of discriminating between guidelines, and could contribute to the lack of deployment we observed. We conducted a thematic analysis of papers identified by means of a systematic literature review to identify a set of dimensions of mobile phone interface design guidelines. The final dimensions provide a mechanism for differentiating guidelines and expediting choice.

  5. Innovative Mobile Smart Photonic Dimensional, Color and Spectral Measurement Engineering

    Science.gov (United States)

    Hofmann, Dr Dietrich, Prof; Dittrich (B. Eng. , Paul-Gerald; Höfner (B. Eng. , Dieter; Kraus, Daniel

    2015-02-01

    Aim of the paper is the demonstration of a paradigm shift in dimensional, color and spectral measurements in industry, biology/medicine, farming/environmental protection and security, as well as in education and training: Measurement engineering and quality assurance become mobile, modular and smart. Smartpads, smartphones and smartwatches (smartcomps) in combination with innovative hardware apps (hwapps) and conventional software apps (swapps) are fundamental enablers for the transformation from conventional stationary working places towards innovative mobile working places with in-field measurements and point-of-care (POC) diagnostics. Furthermore mobile open online courses (MOOCs) are transforming the study habits. Practical examples for the application of innovative photonic micro dimensiometers, colorimeters and spectrometers will be given. The innovative approach opens so far untapped enormous markets for measurement science, engineering, applications, education and training. These innovative working conditions will be fast accepted due to their convenience, reliability and affordability. A highly visible advantage of smartcomps is the huge number of their real distribution, their worldwide connectivity via Internet and cloud services, the standardized interfaces like USB and HDMI and the experienced capabilities of their users for practical operations, obtained with their private smartcomps.

  6. Innovative Mobile Smart Photonic Dimensional, Color and Spectral Measurement Engineering

    International Nuclear Information System (INIS)

    Hofmann, Dietrich; Dittrich, Paul-Gerald; Höfner, Dieter; Kraus, Daniel

    2015-01-01

    Aim of the paper is the demonstration of a paradigm shift in dimensional, color and spectral measurements in industry, biology/medicine, farming/environmental protection and security, as well as in education and training: Measurement engineering and quality assurance become mobile, modular and smart. Smartpads, smartphones and smartwatches (smartcomps) in combination with innovative hardware apps (hwapps) and conventional software apps (swapps) are fundamental enablers for the transformation from conventional stationary working places towards innovative mobile working places with in-field measurements and point-of-care (POC) diagnostics. Furthermore mobile open online courses (MOOCs) are transforming the study habits. Practical examples for the application of innovative photonic micro dimensiometers, colorimeters and spectrometers will be given. The innovative approach opens so far untapped enormous markets for measurement science, engineering, applications, education and training. These innovative working conditions will be fast accepted due to their convenience, reliability and affordability. A highly visible advantage of smartcomps is the huge number of their real distribution, their worldwide connectivity via Internet and cloud services, the standardized interfaces like USB and HDMI and the experienced capabilities of their users for practical operations, obtained with their private smartcomps

  7. Mass-spectrometer of knock-on nuclei for reactor 'Pik'

    International Nuclear Information System (INIS)

    Begzhanov, P.B.; Nazarov, A.G.; Petrov, G.A.; Pikul', V.P.

    1999-01-01

    For reactor 'Pik' (that is being built in St. Petersburg Institute of Nuclear Physics) there was designed a universal two shoulder mass-spectrometer for non-decelerated fission products (FP) of nuclei. The spectrometer helps to obtain different values of linear magnification, dispersion, aberration coefficients and transmission without making structural changes in the device. To separate FP for one shoulder of spectrometer we chose ion-optical scheme (IOS) consisting of three electrostatic analyzers and three-sectional magnet 'JOSEF' that had high dispersion by masses at small deflection radius. IOS calculations of mass-spectrometer were performed with the help of program TRANSVOL (transfer of phase volume) designed basing on TRIO program. The program allows calculating of complete IOS transmission with taking into account elements aperture and beam officering

  8. Incremental projection approach of regularization for inverse problems

    Energy Technology Data Exchange (ETDEWEB)

    Souopgui, Innocent, E-mail: innocent.souopgui@usm.edu [The University of Southern Mississippi, Department of Marine Science (United States); Ngodock, Hans E., E-mail: hans.ngodock@nrlssc.navy.mil [Naval Research Laboratory (United States); Vidard, Arthur, E-mail: arthur.vidard@imag.fr; Le Dimet, François-Xavier, E-mail: ledimet@imag.fr [Laboratoire Jean Kuntzmann (France)

    2016-10-15

    This paper presents an alternative approach to the regularized least squares solution of ill-posed inverse problems. Instead of solving a minimization problem with an objective function composed of a data term and a regularization term, the regularization information is used to define a projection onto a convex subspace of regularized candidate solutions. The objective function is modified to include the projection of each iterate in the place of the regularization. Numerical experiments based on the problem of motion estimation for geophysical fluid images, show the improvement of the proposed method compared with regularization methods. For the presented test case, the incremental projection method uses 7 times less computation time than the regularization method, to reach the same error target. Moreover, at convergence, the incremental projection is two order of magnitude more accurate than the regularization method.

  9. High Resolution Stellar Spectroscopy with VBT Echelle Spectrometer

    Indian Academy of Sciences (India)

    Easy operations. We finally preferred the all transmitting system for the spectrometer with the optical surfaces anti-reflection coated to optimize the throughput rather than reflecting cameras with central obscurations. Following other optimized throughput spectrometers like. Sandiford at McDonald Observatory (McCarthy et al ...

  10. Scanning electron microscopy-energy dispersive X-ray spectrometer ...

    African Journals Online (AJOL)

    The distribution of arsenic (As) and cadmium (Cd) in himematsutake was analyzed using scanning electron microscopy-energy dispersive X-ray spectrometer (SEM-EDX). The atomic percentage of the metals was confirmed by inductively coupled plasma-mass spectrometer (ICP-MS). Results show that the accumulation of ...

  11. Indigenously built resonance ionization mass spectrometer

    International Nuclear Information System (INIS)

    Razvi, M.A.N.; Jayasekharan, T.; Thankarajan, K.; Guhagarkar, M.B.; Dixit, M.N.; Bhale, G.L.

    2000-04-01

    Design, fabrication and performance testing of an indigenously built Resonance Ionization Mass Spectrometer (RIMS) is presented in this report. The instrument is totally indigenous, but for the laser components consisting of the excimer laser and tunable dye lasers. Constructional details of atomic beam source and linear time-of-flight mass spectrometer are included. Finally, commissioning and performance testing of the instrument is described. Mass resolving power of 400 and a detection limit of 100 atoms has been achieved using this RIMS set-up. (author)

  12. Setup of Mössbauer spectrometers at RCPTM

    Science.gov (United States)

    Pechoušek, J.; Jančík, D.; Frydrych, J.; Navařík, J.; Novák, P.

    2012-10-01

    Setup of Mössbauer spectrometers (MS) for structural, phase, and magnetic characterization of iron-or tin-containing samples is presented. This comprehensive line of 57Fe and 119Sn Mössbauer spectrometers covers transmission spectrometers (TMS) for roomtemperature (RT) measurements, temperature dependent measurements and measurements in an external magnetic field. An RT Conversion Electron/Conversion X-ray Mössbauer technique (CEMS/CXMS) is also available. The main concept of the RT MS is a table-top spectrometric bench with a control unit based on special-purpose hardware or standard PC platform. The first way offers a compact design and PC independent spectra collection system. The second setup, a PC-based system, which uses commercial devices and LabVIEW software, offers easy customization and enables advancement in spectrometer construction. The both types of control systems are able to operate special parts (velocity transducers, gamma-ray detectors) of unusual spectrometric benches. The standard velocity axis range is up to ±20 mm/s with a maximum nonlinearity of 0.1%. Applicable measuring conditions of presented TMSs cover a cryogenic temperature range from 1.5 up to 300 K and high temperature range from RT up to 1000 °C. With in-field low-temperature MS, we are able to analyze samples normally in the external magnetic fields up to 8 T (in temperature interval from 1.5 up to 300 K). In addition, special modes of measurements can be applied including backscattering gamma-ray geometry or measurement in an inert or controlled-humidity atmosphere. Technical details and construction aspects of spectrometers are presented.

  13. Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

    Science.gov (United States)

    Seon, Changrae; Hong, Joohwan; Song, Inwoo; Jang, Juhyeok; Lee, Hyeonyong; An, Younghwa; Kim, Bosung; Jeon, Taemin; Park, Jaesun; Choe, Wonho; Lee, Hyeongon; Pak, Sunil; Cheon, MunSeong; Choi, Jihyeon; Kim, Hyeonseok; Biel, Wolfgang; Bernascolle, Philippe; Barnsley, Robin; O'Mullane, Martin

    2017-12-01

    Design and development of the ITER divertor VUV spectrometer have been performed from the year 1998, and it is planned to be installed in the year 2027. Currently, the design of the ITER divertor VUV spectrometer is in the phase of detail design. It is optimized for monitoring of chord-integrated VUV signals from divertor plasmas, chosen to contain representative lines emission from the tungsten as the divertor material, and other impurities. Impurity emission from overall divertor plasmas is collimated through the relay optics onto the entrance slit of a VUV spectrometer with working wavelength range of 14.6-32 nm. To validate the design of the ITER divertor VUV spectrometer, two sets of VUV spectrometers have been developed and tested at KSTAR tokamak. One set of spectrometer without the field mirror employs a survey spectrometer with the wavelength ranging from 14.6 nm to 32 nm, and it provides the same optical specification as the spectrometer part of the ITER divertor VUV spectrometer system. The other spectrometer with the wavelength range of 5-25 nm consists of a commercial spectrometer with a concave grating, and the relay mirrors with the same geometry as the relay mirrors of the ITER divertor VUV spectrometer. From test of these prototypes, alignment method using backward laser illumination could be verified. To validate the feasibility of tungsten emission measurement, furthermore, the tungsten powder was injected in KSTAR plasmas, and the preliminary result could be obtained successfully with regard to the evaluation of photon throughput. Contribution to the Topical Issue "Atomic and Molecular Data and their Applications", edited by Gordon W.F. Drake, Jung-Sik Yoon, Daiji Kato, Grzegorz Karwasz.

  14. Design and construction of a NIR spectrometer

    CERN Document Server

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  15. 1987 calibration of the TFTR neutron spectrometers

    International Nuclear Information System (INIS)

    Barnes, C.W.; Strachan, J.D.; Princeton Univ., NJ

    1989-12-01

    The 3 He neutron spectrometer used for measuring ion temperatures and the NE213 proton recoil spectrometer used for triton burnup measurements were absolutely calibrated with DT and DD neutron generators placed inside the TFTR vacuum vessel. The details of the detector response and calibration are presented. Comparisons are made to the neutron source strengths measured from other calibrated systems. 23 refs., 19 figs., 6 tabs

  16. Design and construction of a NIR spectrometer

    International Nuclear Information System (INIS)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  17. Incremental Frequent Subgraph Mining on Large Evolving Graphs

    KAUST Repository

    Abdelhamid, Ehab; Canim, Mustafa; Sadoghi, Mohammad; Bhatta, Bishwaranjan; Chang, Yuan-Chi; Kalnis, Panos

    2017-01-01

    , such as social networks, utilize large evolving graphs. Mining these graphs using existing techniques is infeasible, due to the high computational cost. In this paper, we propose IncGM+, a fast incremental approach for continuous frequent subgraph mining problem

  18. Parallel Algorithm for Incremental Betweenness Centrality on Large Graphs

    KAUST Repository

    Jamour, Fuad Tarek

    2017-10-17

    Betweenness centrality quantifies the importance of nodes in a graph in many applications, including network analysis, community detection and identification of influential users. Typically, graphs in such applications evolve over time. Thus, the computation of betweenness centrality should be performed incrementally. This is challenging because updating even a single edge may trigger the computation of all-pairs shortest paths in the entire graph. Existing approaches cannot scale to large graphs: they either require excessive memory (i.e., quadratic to the size of the input graph) or perform unnecessary computations rendering them prohibitively slow. We propose iCentral; a novel incremental algorithm for computing betweenness centrality in evolving graphs. We decompose the graph into biconnected components and prove that processing can be localized within the affected components. iCentral is the first algorithm to support incremental betweeness centrality computation within a graph component. This is done efficiently, in linear space; consequently, iCentral scales to large graphs. We demonstrate with real datasets that the serial implementation of iCentral is up to 3.7 times faster than existing serial methods. Our parallel implementation that scales to large graphs, is an order of magnitude faster than the state-of-the-art parallel algorithm, while using an order of magnitude less computational resources.

  19. Three new extreme ultraviolet spectrometers on NSTX-U for impurity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Weller, M. E., E-mail: weller4@llnl.gov; Beiersdorfer, P.; Soukhanovskii, V. A.; Magee, E. W.; Scotti, F. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2016-11-15

    Three extreme ultraviolet (EUV) spectrometers have been mounted on the National Spherical Torus Experiment–Upgrade (NSTX-U). All three are flat-field grazing-incidence spectrometers and are dubbed X-ray and Extreme Ultraviolet Spectrometer (XEUS, 8–70 Å), Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS, 190–440 Å), and Metal Monitor and Lithium Spectrometer Assembly (MonaLisa, 50–220 Å). XEUS and LoWEUS were previously implemented on NSTX to monitor impurities from low- to high-Z sources and to study impurity transport while MonaLisa is new and provides the system increased spectral coverage. The spectrometers will also be a critical diagnostic on the planned laser blow-off system for NSTX-U, which will be used for impurity edge and core ion transport studies, edge-transport code development, and benchmarking atomic physics codes.

  20. Estimation of incremental reactivities for multiple day scenarios: an application to ethane and dimethyoxymethane

    Science.gov (United States)

    Stockwell, William R.; Geiger, Harald; Becker, Karl H.

    Single-day scenarios are used to calculate incremental reactivities by definition (Carter, J. Air Waste Management Assoc. 44 (1994) 881-899.) but even unreactive organic compounds may have a non-negligible effect on ozone concentrations if multiple-day scenarios are considered. The concentration of unreactive compounds and their products may build up over a multiple-day period and the oxidation products may be highly reactive or highly unreactive affecting the overall incremental reactivity of the organic compound. We have developed a method for calculating incremental reactivities for multiple days based on a standard scenario for polluted European conditions. This method was used to estimate maximum incremental reactivities (MIR) and maximum ozone incremental reactivities (MOIR) for ethane and dimethyoxymethane for scenarios ranging from 1 to 6 days. It was found that the incremental reactivities increased as the length of the simulation period increased. The MIR of ethane increased faster than the value for dimethyoxymethane as the scenarios became longer. The MOIRs of ethane and dimethyoxymethane increased but the change was more modest for scenarios longer than 3 days. MOIRs of both volatile organic compounds were equal within the uncertainties of their chemical mechanisms by the 5 day scenario. These results show that dimethyoxymethane has an ozone forming potential on a per mass basis that is only somewhat greater than ethane if multiple-day scenarios are considered.

  1. IPNS-I chopper spectrometers

    International Nuclear Information System (INIS)

    Price, D.L.; Carpenter, J.M.; Pelizzari, C.A.; Sinha, S.K.; Bresof, I.; Ostrowski, G.E.

    1982-01-01

    We briefly describe the layout and operation of the two chopper experiments at IPNS-I. The recent measurement on solid 4 He by Hilleke et al. provides examples of time-of-flight data from the Low Resolution Chopper Spectrometer

  2. Deep-water gamma-spectrometer based on HP(Ge) detector

    International Nuclear Information System (INIS)

    Sokolov, A.; Danengirsh, S.; Popov, S.; Pchelincev, A; Gostilo, V.; Kravchenko, S.; Shapovalov, V.; Druzhinin, A.

    1995-01-01

    Full text: For radionuclide monitoring of the sea bottom near underwater storage of high active waste of nuclear industries and near places of accidents with nuclear submarines the spectrometers of gamma-radiation, which allow to carry out the measurements on the great depth, are needed. Usually, these problems are solved with devices, which are cast down into the water, using the rope, and transmit the signals on the surface by the cable. However, the depth of immersion is limited by this construction and often the conditions of measurement are complicated. The deep water gamma-spectrometer based on HP(Ge) detector for the measurement on the depth up to 3000 m is developed. The spectrometer is completely autonomic and is put up in the selected place, using the manipulator of a deep-water apparatus. The spectrometer is created in two cylindrical cases with 170 mm diameter and 1100 mm length, bearing the high hydrostatic pressure. The part of the case around the detector is created from titanium and has especial construction with a thin wall for increasing the efficiency of registration in the region of low-energy gamma-radiation. The cooling of the semiconductor detector is provided by a coolant which supports the working temperature of the detector during more than 24 hours. The electronic system of the spectrometer includes high voltage supply f or the detector, preamplifier, analog processor, analog-digital converter and a device for collecting and storing information in flash memory. The power supply of the spectrometer is provided by a battery of accumulators, which can be recharged on the surface. The programming of the processor is carried out before immersion by connecting the spectrometer to personal computer using standard interface RS-232. During 24 hours the spectrometer provides registration of 16 spectrums each in 4096 channels. The reading of the information by the computer is carried out after lifting up the spectrometer on the surface in the same

  3. Investigation of background processes in the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Axel [Karlsruhe Institute of Technology (KIT), Institut fuer Kernphysik (IKP) (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The KArlsruhe TRItium Neutrino experiment aims to probe the mass of the electron antineutrino in a model-independent way with an unsurpassed sensitivity of m{sub ν}=200 meV/c{sup 2} (90% C.L.). In order to determine the neutrino mass, the energy spectrum of electrons from the tritium β-decay is analyzed by a high-resolution electrostatic spectrometer which is based on the MAC-E filter principle. To keep the influence of the spectrometer background on the neutrino mass sensitivity small, KATRIN aims for a background level of 0.01 cps. For the investigation of different background components such as cosmic muons, external gamma radiation and the radioactive decay of isotopes in the volume of the spectrometer or on its surface, a series of dedicated measurements were performed with a combined system of main spectrometer and detector. This talk presents the results of measurements focusing on the secondary electron production at the inner surface of the spectrometer and compare them with electro-magnetic electron tracking simulations performed with the KATRIN developed simulation software KASSIOPEIA.

  4. [Spatiotemporal variation of Populus euphratica's radial increment at lower reaches of Tarim River after ecological water transfer].

    Science.gov (United States)

    An, Hong-Yan; Xu, Hai-Liang; Ye, Mao; Yu, Pu-Ji; Gong, Jun-Jun

    2011-01-01

    Taking the Populus euphratica at lower reaches of Tarim River as test object, and by the methods of tree dendrohydrology, this paper studied the spatiotemporal variation of P. euphratic' s branch radial increment after ecological water transfer. There was a significant difference in the mean radial increment before and after ecological water transfer. The radial increment after the eco-water transfer was increased by 125%, compared with that before the water transfer. During the period of ecological water transfer, the radial increment was increased with increasing water transfer quantity, and there was a positive correlation between the annual radial increment and the total water transfer quantity (R2 = 0.394), suggesting that the radial increment of P. euphratica could be taken as the performance indicator of ecological water transfer. After the ecological water transfer, the radial increment changed greatly with the distance to the River, i.e. , decreased significantly along with the increasing distance to the River (P = 0.007). The P. euphratic' s branch radial increment also differed with stream segment (P = 0.017 ), i.e. , the closer to the head-water point (Daxihaizi Reservoir), the greater the branch radial increment. It was considered that the limited effect of the current ecological water transfer could scarcely change the continually deteriorating situation of the lower reaches of Tarim River.

  5. [Incremental cost effectiveness of multifocal cataract surgery].

    Science.gov (United States)

    Pagel, N; Dick, H B; Krummenauer, F

    2007-02-01

    Supplementation of cataract patients with multifocal intraocular lenses involves an additional financial investment when compared to the corresponding monofocal supplementation, which usually is not funded by German health care insurers. In the context of recent resource allocation discussions, however, the cost effectiveness of multifocal cataract surgery could become an important rationale. Therefore an evidence-based estimation of its cost effectiveness was carried out. Three independent meta-analyses were implemented to estimate the gain in uncorrected near visual acuity and best corrected visual acuity (vision lines) as well as the predictability (fraction of patients without need for reading aids) of multifocal supplementation. Study reports published between 1995 and 2004 (English or German language) were screened for appropriate key words. Meta effects in visual gain and predictability were estimated by means and standard deviations of the reported effect measures. Cost data were estimated by German DRG rates and individual lens costs; the cost effectiveness of multifocal cataract surgery was then computed in terms of its marginal cost effectiveness ratio (MCER) for each clinical benefit endpoint; the incremental costs of multifocal versus monofocal cataract surgery were further estimated by means of their respective incremental cost effectiveness ratio (ICER). An independent meta-analysis estimated the complication profiles to be expected after monofocal and multifocal cataract surgery in order to evaluate expectable complication-associated additional costs of both procedures; the marginal and incremental cost effectiveness estimates were adjusted accordingly. A sensitivity analysis comprised cost variations of +/- 10 % and utility variations alongside the meta effect estimate's 95 % confidence intervals. Total direct costs from the health care insurer's perspective were estimated 3363 euro, associated with a visual meta benefit in best corrected visual

  6. BIS-2 spectrometer for search and investigation of narrow resonances

    International Nuclear Information System (INIS)

    Aleev, A.N.; Aref'ev, V.A.; Balandin, V.P.

    1989-01-01

    The configuration and main characteristics of the BIS-2 spectrometer are described. The spectrometer was intended to search for and to investigate charmed particles and narrow resonances produced in neutron-nucleus interactions. It was placed on a neutron beam of the Serpukhov accelerator. The Monte-Carlo simulated and experimentally measured characteristics of individual elements and the spectrometer as a whole are described. A brief review of the principal results based on the analysis of more than 10 7 neutron-nucleus interactions registered by means of the BIS-2 spectrometer is given. 34 refs.; 8 figs.; 5 tabs

  7. Lactate and ammonia concentration in blood and sweat during incremental cycle ergometer exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Mook, GA; Gips, CH; Verkerke, GJ

    It is known that the concentrations of ammonia and lactate in blood increase during incremental exercise. Sweat also contains lactate and ammonia. The aim of the present study was to investigate the physiological response of lactate and ammonia in plasma and sweat during a stepwise incremental cycle

  8. Beam-transport optimization for cold-neutron spectrometer

    Directory of Open Access Journals (Sweden)

    Nakajima Kenji

    2015-01-01

    Full Text Available We report the design of the beam-transport system (especially the vertical geometry for a cold-neutron disk-chopper spectrometer AMATERAS at J-PARC. Based on the elliptical shape, which is one of the most effective geometries for a ballistic mirror, the design was optimized to obtain, at the sample position, a neutron beam with high flux without serious degrading in divergence and spacial homogeneity within the boundary conditions required from actual spectrometer construction. The optimum focal point was examined. An ideal elliptical shape was modified to reduce its height without serious loss of transmission. The final result was adapted to the construction requirements of AMATERAS. Although the ideas studied in this paper are considered for the AMATERAS case, they can be useful also to other spectrometers in similar situations.

  9. A compact multichannel spectrometer for Thomson scattering

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R. [Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53706 (United States)

    2012-10-15

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T{sub e} < 100 eV are achieved by a 2971 l/mm VPH grating and measurements T{sub e} > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated ({approx}2 ns) ICCD camera for detection. A Gen III image intensifier provides {approx}45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  10. Potential stocks and increments of woody biomass in the European Union under different management and climate scenarios.

    Science.gov (United States)

    Kindermann, Georg E; Schörghuber, Stefan; Linkosalo, Tapio; Sanchez, Anabel; Rammer, Werner; Seidl, Rupert; Lexer, Manfred J

    2013-02-01

    Forests play an important role in the global carbon flow. They can store carbon and can also provide wood which can substitute other materials. In EU27 the standing biomass is steadily increasing. Increments and harvests seem to have reached a plateau between 2005 and 2010. One reason for reaching this plateau will be the circumstance that the forests are getting older. High ages have the advantage that they typical show high carbon concentration and the disadvantage that the increment rates are decreasing. It should be investigated how biomass stock, harvests and increments will develop under different climate scenarios and two management scenarios where one is forcing to store high biomass amounts in forests and the other tries to have high increment rates and much harvested wood. A management which is maximising standing biomass will raise the stem wood carbon stocks from 30 tC/ha to 50 tC/ha until 2100. A management which is maximising increments will lower the stock to 20 tC/ha until 2100. The estimates for the climate scenarios A1b, B1 and E1 are different but there is much more effect by the management target than by the climate scenario. By maximising increments the harvests are 0.4 tC/ha/year higher than in the management which maximises the standing biomass. The increments until 2040 are close together but around 2100 the increments when maximising standing biomass are approximately 50 % lower than those when maximising increments. Cold regions will benefit from the climate changes in the climate scenarios by showing higher increments. The results of this study suggest that forest management should maximise increments, not stocks to be more efficient in sense of climate change mitigation. This is true especially for regions which have already high carbon stocks in forests, what is the case in many regions in Europe. During the time span 2010-2100 the forests of EU27 will absorb additional 1750 million tC if they are managed to maximise increments compared

  11. X-ray fluorescence spectrometers: a comparison of wavelength and energy dispersive instruments

    International Nuclear Information System (INIS)

    Slates, R.V.

    1977-11-01

    Wavelength dispersive and energy dispersive x-ray fluorescence spectrometers are compared. Separate sections are devoted to principles of operation, sample excitation, spectral resolution, and x-ray detection. Tabulated data from the literature are cited in the comparison of accuracy, precision, and detection limits. Spectral interferences and distortions are discussed. Advantages and limitations are listed for simultaneous wavelength dispersive spectrometers, sequential wavelength dispersive spectrometers, and Si(Li) energy dispersive spectrometers. Accuracy, precision, and detection limits are generally superior for wavelength dispersive spectrometers

  12. Proton-bound cluster ions in ion mobility spectrometry

    Science.gov (United States)

    Ewing, R. G.; Eiceman, G. A.; Stone, J. A.

    1999-01-01

    Gaseous oxygen and nitrogen bases, both singly and as binary mixtures, have been introduced into ion mobility spectrometers to study the appearance of protonated molecules, and proton-bound dimers and trimers. At ambient temperature it was possible to simultaneously observe, following the introduction of molecule A, comparable intensities of peaks ascribable to the reactant ion (H2O)nH+, the protonated molecule AH+ and AH+ H2O, and the symmetrical proton bound dimer A2H+. Mass spectral identification confirmed the identifications and also showed that the majority of the protonated molecules were hydrated and that the proton-bound dimers were hydrated to a much lesser extent. No significant peaks ascribable to proton-bound trimers were obtained no matter how high the sample concentration. Binary mixtures containing molecules A and B, in some cases gave not only the peaks unique to the individual compounds but also peaks due to asymmetrical proton bound dimers AHB+. Such ions were always present in the spectra of mixtures of oxygen bases but were not observed for several mixtures of oxygen and nitrogen bases. The dimers, which were not observable, notable for their low hydrogen bond strengths, must have decomposed in their passage from the ion source to the detector, i.e. in a time less than approximately 5 ms. When the temperature was lowered to -20 degrees C, trimers, both homogeneous and mixed, were observed with mixtures of alcohols. The importance of hydrogen bond energy, and hence operating temperature, in determining the degree of solvation of the ions that will be observed in an ion mobility spectrometer is stressed. The possibility is discussed that a displacement reaction involving ambient water plays a role in the dissociation.

  13. Discrimination of bacteria by rapid sensing their metabolic volatiles using an aspiration-type ion mobility spectrometer (a-IMS) and gas chromatography-mass spectrometry GC-MS.

    Science.gov (United States)

    Ratiu, Ileana Andreea; Bocos-Bintintan, Victor; Patrut, Adrian; Moll, Victor Hugo; Turner, Matthew; Thomas, C L Paul

    2017-08-22

    The objective of our study was to investigate whether one may quickly and reliably discriminate different microorganism strains by direct monitoring of the headspace atmosphere above their cultures. Headspace samples above a series of in vitro bacterial cultures were directly interrogated using an aspiration type ion mobility spectrometer (a-IMS), which produced distinct profiles ("fingerprints") of ion currents generated simultaneously by the detectors present inside the ion mobility cell. Data processing and analysis using principal component analysis showed net differences in the responses produced by volatiles emitted by various bacterial strains. Fingerprint assignments were conferred on the basis of product ion mobilities; ions of differing size and mass were deflected in a different degree upon their introduction of a transverse electric field, impacting finally on a series of capacitors (denominated as detectors, or channels) placed in a manner analogous to sensor arrays. Three microorganism strains were investigated - Escherichia coli, Bacillus subtilis and Staphylococcus aureus; all strains possess a relatively low pathogenic character. Samples of air with a 5 cm 3 volume from the headspace above the bacterial cultures in agar growth medium were collected using a gas-tight chromatographic syringe and injected inside the closed-loop pneumatic circuit of the breadboard a-IMS instrument model ChemPro-100i (Environics Oy, Finland), at a distance of about 1 cm from the ionization source. The resulting chemical fingerprints were produced within two seconds from the moment of injection. The sampling protocol involved to taking three replicate samples from each of 10 different cultures for a specific strain, during a total period of 72 h after the initial incubation - at 24, 48 and 72 h, respectively. Principal component analysis (PCA) was used to discriminate between the IMS fingerprints. PCA was found to successfully discriminate between bacteria at three

  14. FOCUS: neutron time-of-flight spectrometer at SINQ: recent progress

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, S.; Mesot, J.; Holitzner, L. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Hempelmann, R. [Saarbruecken Univ. (Germany)

    1997-09-01

    At the Swiss neutron spallation source SINQ a time-of-flight spectrometer for cold neutrons is under construction. The design foresees a Hybrid solution combining a Fermi chopper with a doubly focusing crystal monochromator. During 1996 important progress has been made concerning the main spectrometer components such as the spectrometer housing and the detector system. (author) 2 figs., 3 refs.

  15. Upgrade of an old Raman Spectrometer

    DEFF Research Database (Denmark)

    Hansen, Susanne Brunsgaard; Berg, Rolf W.; Stenby, Erling Halfdan

    2004-01-01

    Improvement of a conventional Jeol Raman spectrometer with a single channel photo multiplier detector is described. New optical components (fibres, mirror, lens and CCD detector) have been chosen to design a high quality and easy-to-use instrument. Tests have shown that with this modified...... spectrometer Raman spectra can be acquired of a quality comparable to the spectra obtained previously, but the time needed to obtain a spectrum is markedly reduced. Selected test spectra and a simple calibration procedure to obtain the wavenumber values from the band CCD pixel position are presented....

  16. Spectrometer Baseline Control Via Spatial Filtering

    Science.gov (United States)

    Burleigh, M. R.; Richey, C. R.; Rinehart, S. A.; Quijada, M. A.; Wollack, E. J.

    2016-01-01

    An absorptive half-moon aperture mask is experimentally explored as a broad-bandwidth means of eliminating spurious spectral features arising from reprocessed radiation in an infrared Fourier transform spectrometer. In the presence of the spatial filter, an order of magnitude improvement in the fidelity of the spectrometer baseline is observed. The method is readily accommodated within the context of commonly employed instrument configurations and leads to a factor of two reduction in optical throughput. A detailed discussion of the underlying mechanism and limitations of the method are provided.

  17. A driving system for Moessbauer spectrometer

    International Nuclear Information System (INIS)

    Maslan, M.; Cholmeckij, A.; Evdokimov, V.; Misevic, O.; Fedorov, A.; Zak, D.

    1993-01-01

    The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 ± 0.01 mm/s. (author). 6 figs., 8 refs

  18. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects; Portativnyj stsintillyatsionnyj gamma-spektrometr dlya izmereniya radioaktivnosti ob''emnykh sred v polevykh usloviyakh

    Energy Technology Data Exchange (ETDEWEB)

    Besshejko, O. A. [Taras Shevchenko National University of Kyiv, Kyiv (Ukraine); Vishnevskij, I. N.; Denisenko, R. V.; Malyuk, I. A.; Petrosyan, Eh. E. [Institute for Nuclear Research, Kyiv (Ukraine); Karpenko, S. A.; Prijmak, V. N. [Ukrainian Association for Valves Industry, Dnepropetrovsk (Ukraine)

    2011-07-01

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO{sub 4} that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4{pi}-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  19. Opening the terahertz window on the OSIRIS spectrometer

    Directory of Open Access Journals (Sweden)

    Demmel F.

    2015-01-01

    Full Text Available A cooled and mechanically retractable beryllium filter has been installed and commissioned on the low-energy OSIRIS spectrometer at ISIS. This instrument development extends the energy-transfer range of the spectrometer up to ca. 20 meV (∼ 5 THz, leading to an excellent resolution at THz frequencies and substantial gains in detected flux relative to existing capabilities on the neighbouring IRIS spectrometer. Herein, we provide a concise account of this new capability for high-resolution neutron spectroscopy in the THz domain, as well as outline a number of ongoing and potential scientific opportunities in condensed-matter physics, chemistry, and materials science.

  20. Sensitivity and response time improvements in millimeter-wave spectrometers

    International Nuclear Information System (INIS)

    Kolbe, W.F.; Leskovar, B.

    1980-09-01

    A new version of a microwave spectrometer for the detection of gaseous pollutants and other atmospheric constituents is described. The spectrometer, which operates in the vicinity of 70 GHz, employs a Fabry-Perot resonator as a sample cell and uses superhetrodyne detection for high sensitivity. The spectrometer has been modified to incorporate a frequency doubler modulated at 30 MHz to permit operation with a single Gunn oscillator source. As a result, faster response time and somewhat greater sensitivity are obtained. The spectrometer is capable of detecting a minimum concentration of 1 ppM of SO 2 diluted in air with a 1 second time constant. For OCS diluted in air, the minimum detectable concentration is 800 ppB and with a 10 second time constant 300 ppB

  1. 4D space access neutron spectrometer 4SEASONS (SIKI)

    International Nuclear Information System (INIS)

    Kajimoto, Ryoichi; Nakamura, Mitsutaka

    2010-01-01

    The 4D Space Access Neutron Spectrometer (4SEASONS) is a high-intensity Fermi-chopper spectrometer. It is intended to provide high counting rate for thermal neutrons with medium resolution (ΔE/E i -6% at E=0) to efficiently collect weak inelastic signals from novel spin and lattice dynamics especially in high-T c superconductors and related materials. To achieve this goal, the spectrometer equips advanced instrumental design such as an elliptic-shaped converging neutron guide coated with high-Q c (m=3-4) supermirror, and long-length (2.5 m) 3 He position sensitive detectors (PSDs) arranged cylindrically inside the vacuum scattering chamber. Furthermore, the spectrometer is ready for multi-incident-energy measurements by the repetition rate multiplication method, which greatly improves the measurement efficiency. (author)

  2. Extending The Useful Life Of Older Mass Spectrometers

    International Nuclear Information System (INIS)

    Johnson, S.; Cordaro, J.; Holland, M.; Jones, V.

    2010-01-01

    Thermal ionization and gas mass spectrometers are widely used across the Department of Energy (DOE) Complex and contractor laboratories. These instruments support critical missions, where high reliability and low measurement uncertainty are essential. A growing number of these mass spectrometers are significantly older than their original design life. The reality is that manufacturers have declared many of the instrument models obsolete, with direct replacement parts and service no longer available. Some of these obsolete models do not have a next generation, commercially available replacement. Today's budget conscious economy demands for the use of creative funds management. Therefore, the ability to refurbish (or upgrade) these valuable analytical tools and extending their useful life is a cost effective option. The Savannah River Site (SRS) has the proven expertise to breathe new life into older mass spectrometers, at a significant cost savings compared to the purchase and installation of new instruments. A twenty-seven year old Finnigan MAT-261(trademark) Thermal Ionization Mass Spectrometer (TIMS), located at the SRS F/H Area Production Support Laboratory, has been successfully refurbished. Engineers from the Savannah River National Laboratory (SRNL) fabricated and installed the new electronics. These engineers also provide continued instrument maintenance services. With electronic component drawings being DOE Property, other DOE Complex laboratories have the option to extend the life of their aged Mass Spectrometers.

  3. PCA/INCREMENT MEMORY interface for analog processors on-line with PC-XT/AT IBM

    International Nuclear Information System (INIS)

    Biri, S.; Buttsev, V.S.; Molnar, J.; Samojlov, V.N.

    1989-01-01

    The functional and operational descriptions on PCA/INCREMENT MEMORY interface are discussed. The following is solved with this unit: connection between the analogue signal processor and PC, nuclear spectrum acquisition up to 2 24 -1 counts/channel using increment or decrement method, data read/write from or to memory via data bus PC during the spectrum acquisition. Dual ported memory organization is 4096x24 bit, increment cycle time at 4.77 MHz system clock frequency is 1.05 μs. 6 refs.; 2 figs

  4. Playing by the rules? Analysing incremental urban developments

    NARCIS (Netherlands)

    Karnenbeek, van Lilian; Janssen-Jansen, Leonie

    2018-01-01

    Current urban developments are often considered outdated and static, and the argument follows that they should become more adaptive. In this paper, we argue that existing urban development are already adaptive and incremental. Given this flexibility in urban development, understanding changes in the

  5. Cyclotrons as mass spectrometers

    International Nuclear Information System (INIS)

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures

  6. Microprocessor monitored Auger spectrometer

    International Nuclear Information System (INIS)

    Sapin, Michel; Ghaleb, Dominique; Pernot, Bernard.

    1982-05-01

    The operation of an Auger spectrometer, used for studying surface impurity diffusion, has been fully automatized with the help of a microprocessor. The characteristics, performance and practical use of the system are described together with the main advantage for the experimentator [fr

  7. A program for the numerical control of a pulse increment system

    Energy Technology Data Exchange (ETDEWEB)

    Gray, D.C.

    1963-08-21

    This report will describe the important features of the development of magnetic tapes for the numerical control of a pulse-increment system consisting of a modified Gorton lathe and its associated control unit developed by L. E. Foley of Equipment Development Service, Engineering Services, General Electric Co., Schenectady, N.Y. Included is a description of CUPID (Control and Utilization of Pulse Increment Devices), a FORTRAN program for the design of these tapes on the IBM 7090 computer, and instructions for its operation.

  8. BMI and BMI SDS in childhood: annual increments and conditional change

    OpenAIRE

    Brannsether-Ellingsen, Bente; Eide, Geir Egil; Roelants, Mathieu; Bjerknes, Robert; Juliusson, Petur Benedikt

    2016-01-01

    Background: Early detection of abnormal weight gain in childhood may be important for preventive purposes. It is still debated which annual changes in BMI should warrant attention. Aim: To analyse 1-year increments of Body Mass Index (BMI) and standardised BMI (BMI SDS) in childhood and explore conditional change in BMI SDS as an alternative method to evaluate 1-year changes in BMI. Subjects and methods: The distributions of 1-year increments of BMI (kg/m2) and BMI SDS are summarised by...

  9. Decoupled Simulation Method For Incremental Sheet Metal Forming

    International Nuclear Information System (INIS)

    Sebastiani, G.; Brosius, A.; Tekkaya, A. E.; Homberg, W.; Kleiner, M.

    2007-01-01

    Within the scope of this article a decoupling algorithm to reduce computing time in Finite Element Analyses of incremental forming processes will be investigated. Based on the given position of the small forming zone, the presented algorithm aims at separating a Finite Element Model in an elastic and an elasto-plastic deformation zone. Including the elastic response of the structure by means of model simplifications, the costly iteration in the elasto-plastic zone can be restricted to the small forming zone and to few supporting elements in order to reduce computation time. Since the forming zone moves along the specimen, an update of both, forming zone with elastic boundary and supporting structure, is needed after several increments.The presented paper discusses the algorithmic implementation of the approach and introduces several strategies to implement the denoted elastic boundary condition at the boundary of the plastic forming zone

  10. Automobile sheet metal part production with incremental sheet forming

    Directory of Open Access Journals (Sweden)

    İsmail DURGUN

    2016-02-01

    Full Text Available Nowadays, effect of global warming is increasing drastically so it leads to increased interest on energy efficiency and sustainable production methods. As a result of adverse conditions, national and international project platforms, OEMs (Original Equipment Manufacturers, SMEs (Small and Mid-size Manufacturers perform many studies or improve existing methodologies in scope of advanced manufacturing techniques. In this study, advanced manufacturing and sustainable production method "Incremental Sheet Metal Forming (ISF" was used for sheet metal forming process. A vehicle fender was manufactured with or without die by using different toolpath strategies and die sets. At the end of the study, Results have been investigated under the influence of method and parameters used.Keywords: Template incremental sheet metal, Metal forming

  11. LADEE Neutral Mass Spectrometer Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This bundle contains the data collected by the Neutral Mass Spectrometer (NMS) instrument aboard the Lunar Atmosphere and Dust Environment Explorer (LADEE)...

  12. A perturbed angular correlation spectrometer for material science ...

    Indian Academy of Sciences (India)

    A four-detector perturbed angular correlation (PAC) spectrometer has been developed with ultra-fast BaF2 detectors to acquire four coincidence spectra simultaneously, two at 180° and two at 90°. This spectrometer has double efficiency compared to that of a three-detector set-up. Higher efficiency is desirable for PAC ...

  13. Combined Raman/LIBS spectrometer elegant breadboard: built and tested - and flight model spectrometer unit

    Science.gov (United States)

    Ahlers, B.; Hutchinson, I.; Ingley, R.

    2017-11-01

    A spectrometer for combined Raman and Laser Induced Breakdown Spectroscopy (LIBS) is amongst the different instruments that have been pre-selected for the Pasteur payload of the ExoMars rover. It is regarded as a fundamental, next-generation instrument for organic, mineralogical and elemental characterisation of Martian soil, rock samples and organic molecules. Raman spectroscopy and LIBS will be integrated into a single instrument sharing many hardware commonalities [1]. The combined Raman / LIBS instrument has been recommended as the highest priority mineralogy instrument to be included in the rover's analytical laboratory for the following tasks: Analyse surface and sub-surface soil and rocks on Mars, identify organics in the search for life and determine soil origin & toxicity. The synergy of the system is evident: the Raman spectrometer is dedicated to molecular analysis of organics and minerals; the LIBS provides information on the sample's elemental composition. An international team, under ESA contract and with the leadership of TNO Science and Industry, has built and tested an Elegant Bread Board (EBB) of the combined Raman / LIBS instrument. The EBB comprises a specifically designed, extremely compact, spectrometer with high resolution over a large wavelength range, suitable for both Raman spectroscopy and LIBS measurements. The EBB also includes lasers, illumination and imaging optics as well as fibre optics for light transfer. A summary of the functional and environmental requirements together with a description of the optical design and its expected performance are described in [2]. The EBB was developed and constructed to verify the instruments' end-to-end functional performance with natural samples. The combined Raman / LIBS EBB realisation and test results of natural samples will be presented. For the Flight Model (FM) instrument, currently in the design phase, the Netherlands will be responsible for the design, development and verification of the

  14. Conservation of wildlife populations: factoring in incremental disturbance.

    Science.gov (United States)

    Stewart, Abbie; Komers, Petr E

    2017-06-01

    Progressive anthropogenic disturbance can alter ecosystem organization potentially causing shifts from one stable state to another. This potential for ecosystem shifts must be considered when establishing targets and objectives for conservation. We ask whether a predator-prey system response to incremental anthropogenic disturbance might shift along a disturbance gradient and, if it does, whether any disturbance thresholds are evident for this system. Development of linear corridors in forested areas increases wolf predation effectiveness, while high density of development provides a safe-haven for their prey. If wolves limit moose population growth, then wolves and moose should respond inversely to land cover disturbance. Using general linear model analysis, we test how the rate of change in moose ( Alces alces ) density and wolf ( Canis lupus ) harvest density are influenced by the rate of change in land cover and proportion of land cover disturbed within a 300,000 km 2 area in the boreal forest of Alberta, Canada. Using logistic regression, we test how the direction of change in moose density is influenced by measures of land cover change. In response to incremental land cover disturbance, moose declines occurred where 43% of land cover was disturbed and wolf density declined. Wolves and moose appeared to respond inversely to incremental disturbance with the balance between moose decline and wolf increase shifting at about 43% of land cover disturbed. Conservation decisions require quantification of disturbance rates and their relationships to predator-prey systems because ecosystem responses to anthropogenic disturbance shift across disturbance gradients.

  15. Numerical simulation of pseudoelastic shape memory alloys using the large time increment method

    Science.gov (United States)

    Gu, Xiaojun; Zhang, Weihong; Zaki, Wael; Moumni, Ziad

    2017-04-01

    The paper presents a numerical implementation of the large time increment (LATIN) method for the simulation of shape memory alloys (SMAs) in the pseudoelastic range. The method was initially proposed as an alternative to the conventional incremental approach for the integration of nonlinear constitutive models. It is adapted here for the simulation of pseudoelastic SMA behavior using the Zaki-Moumni model and is shown to be especially useful in situations where the phase transformation process presents little or lack of hardening. In these situations, a slight stress variation in a load increment can result in large variations of strain and local state variables, which may lead to difficulties in numerical convergence. In contrast to the conventional incremental method, the LATIN method solve the global equilibrium and local consistency conditions sequentially for the entire loading path. The achieved solution must satisfy the conditions of static and kinematic admissibility and consistency simultaneously after several iterations. 3D numerical implementation is accomplished using an implicit algorithm and is then used for finite element simulation using the software Abaqus. Computational tests demonstrate the ability of this approach to simulate SMAs presenting flat phase transformation plateaus and subjected to complex loading cases, such as the quasi-static behavior of a stent structure. Some numerical results are contrasted to those obtained using step-by-step incremental integration.

  16. BATS - Backscattering And Time-of-flight Spectrometer

    International Nuclear Information System (INIS)

    Van Eijck, L.; Seydel, T.; Frick, B.; Schober, H.

    2011-01-01

    The new backscattering spectrometer IN16b will go into commissioning end 2011, providing in its final state about ten times higher count rate than its predecessor, IN16. Here we propose to increase its dynamic range by a factor of 7 with the TOF mode extension, BATS. This will make IN16b the leading high resolution backscattering spectrometer for incoherent quasi-elastic and inelastic neutron scattering; it will be competitive to the coarser resolution inverted geometry backscattering spectrometers that are being brought online at spallation sources. The increased dynamic range will extend the scope of science addressed on IN16b, generating considerable potential in fields such as the hydrogen economy (proton conduction, fuel cells, hydrogen storage), soft matter, biology and nano-science (nano-scale confinement, functionalized polymers). Such a large impact can be achieved using only a moderate investment. (authors)

  17. Incremental net social benefit associated with using nuclear-fueled power plants

    International Nuclear Information System (INIS)

    Maoz, I.

    1976-12-01

    The incremental net social benefit (INSB) resulting from nuclear-fueled, rather than coal-fired, electric power generation is assessed. The INSB is defined as the difference between the 'incremental social benefit' (ISB)--caused by the cheaper technology of electric power generation, and the 'incremental social cost' (ISC)--associated with an increased power production, which is induced by cheaper technology. Section 2 focuses on the theoretical and empirical problems associated with the assessment of the long-run price elasticity of the demand for electricity, and the theoretical-econometric considerations that lead to the reasonable estimates of price elasticities of demand from those provided by recent empirical studies. Section 3 covers the theoretical and empirical difficulties associated with the construction of the long-run social marginal cost curves (LRSMC) of electricity. Sections 4 and 5 discuss the assessment methodology and provide numerical examples for the calculation of the INSB resulting from nuclear-fueled power generation

  18. On the validity of the incremental approach to estimate the impact of cities on air quality

    Science.gov (United States)

    Thunis, Philippe

    2018-01-01

    The question of how much cities are the sources of their own air pollution is not only theoretical as it is critical to the design of effective strategies for urban air quality planning. In this work, we assess the validity of the commonly used incremental approach to estimate the likely impact of cities on their air pollution. With the incremental approach, the city impact (i.e. the concentration change generated by the city emissions) is estimated as the concentration difference between a rural background and an urban background location, also known as the urban increment. We show that the city impact is in reality made up of the urban increment and two additional components and consequently two assumptions need to be fulfilled for the urban increment to be representative of the urban impact. The first assumption is that the rural background location is not influenced by emissions from within the city whereas the second requires that background concentration levels, obtained with zero city emissions, are equal at both locations. Because the urban impact is not measurable, the SHERPA modelling approach, based on a full air quality modelling system, is used in this work to assess the validity of these assumptions for some European cities. Results indicate that for PM2.5, these two assumptions are far from being fulfilled for many large or medium city sizes. For this type of cities, urban increments are largely underestimating city impacts. Although results are in better agreement for NO2, similar issues are met. In many situations the incremental approach is therefore not an adequate estimate of the urban impact on air pollution. This poses issues in terms of interpretation when these increments are used to define strategic options in terms of air quality planning. We finally illustrate the interest of comparing modelled and measured increments to improve our confidence in the model results.

  19. Two-lens spectrometer for. beta. polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Holdsworth, D; Paul, D [Toronto Univ., Ontario (Canada). Dept. of Physics

    1984-06-01

    A test spectrometer has been built having four degrees of freedom which have been varied to optimize the transmission in a configuration in which the image distance is large compared to the object distance. Iron-clad magnets of 15 cm effective inside diameter were used. Within the limits of the primary magnet field, the optimized transmission T (%. of 4..pi.. sr) increases as the source is advanced through the magnet towards the polarimeter, approximately as T=5.1 exp(zsub(s)/10.5), where zsub(s) is in cm, measured from the position of peak axial field. When the source-image distance is 1.8 m the optimum separation of the peak axial fields of the magnets is 67+-1 cm and the spectrometer transmission is the same for parallel or antiparallel fields. When operating in the optimum configuration, the spectrometer accepts particles with initial trajectories from 18/sup 0/ to 42/sup 0/ relative to the axis and delivers them at the target with half-angle of convergence less than 4.1/sup 0/.

  20. MSAT: A booster for land based mobile radiocommunication networks?

    Science.gov (United States)

    Boulay, Guy

    1990-01-01

    It is demonstrated that the foreseen phenomenal growth of mobilesat services will impact positively existing terrestrial mobile radio services. Mobilesat systems will not displace the existing terrestrial market in the near future, partly due to the high cost of their terminal units and associated airtime, but also due to some technical limitations, such as lack of spectrum efficiency and high susceptibility to shadowing. However, the ubiquity of mobilesat services will open new market to terrestrial radio technologies. The latter is expected to be the most economical way of extending locally mobilesat services to many users. Conversely, mobilesat systems will be used to extend the capabilities of terrestrial radio systems in areas where the former cannot be implemented cost effectively. It is believed that terrestrial mobile network operators using these service extension capabilities will have a competitive advantage over those who do not. Overall, it is expected that emerging mobilesat services, far from being a threat to terrestrial radio systems, will rather provide these with numerous opportunities of incrementing their base market.

  1. Mobile marketing for mobile games

    OpenAIRE

    Vu, Giang

    2016-01-01

    Highly developed mobile technology and devices enable the rise of mobile game industry and mobile marketing. Hence mobile marketing for mobile game is an essential key for a mobile game success. Even though there are many articles on marketing for mobile games, there is a need of highly understanding mobile marketing strategies, how to launch a mobile campaign for a mobile game. Besides that, it is essential to understand the relationship between mobile advertising and users behaviours. There...

  2. Portable spectrometer monitors inert gas shield in welding process

    Science.gov (United States)

    Grove, E. L.

    1967-01-01

    Portable spectrometer using photosensitive readouts, monitors the amount of oxygen and hydrogen in the inert gas shield of a tungsten-inert gas welding process. A fiber optic bundle transmits the light from the welding arc to the spectrometer.

  3. Bipower variation for Gaussian processes with stationary increments

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Corcuera, José Manuel; Podolskij, Mark

    2009-01-01

    Convergence in probability and central limit laws of bipower variation for Gaussian processes with stationary increments and for integrals with respect to such processes are derived. The main tools of the proofs are some recent powerful techniques of Wiener/Itô/Malliavin calculus for establishing...

  4. The National Institute of Education and Incremental Budgeting.

    Science.gov (United States)

    Hastings, Anne H.

    1979-01-01

    The National Institute of Education's (NIE) history demonstrates that the relevant criteria for characterizing budgeting as incremental are not the predictability and stability of appropriations but the conditions of complexity, limited information, multiple factors, and imperfect agreement on ends; NIE's appropriations were dominated by political…

  5. CHIRON – A new high resolution spectrometer for CTIO

    Directory of Open Access Journals (Sweden)

    Marcy G.W.

    2011-07-01

    Full Text Available Small telescopes can play an important role in the search for exoplanets because they offer an opportunity for high cadence observations that are not possible with large aperture telescopes. However, there is a shortage of high resolution spectrometers for precision Doppler planet searches. We report on an innovative design for CHIRON, an inexpensive spectrometer that we are building for the 1.5-m telescope at CTIO in Chile. The resolution will be R >80.000, the spectral format spanning 410 to 880 nm. The total throughput of the telescope and spectrometer will be better than 12%, comparable with the efficiency of state-of-the-art spectrometers. The design is driven by the requirements for precision Doppler searches for exoplanets using an iodine cell. The optical layout is a classical echelle with 140 mm beam size. The bench-mounted spectrometer will be fibre-fed followed by an image slicer. An apochromatic refractor is used as the camera. Image quality and throughput of the design are excellent over the full spectral range. Extensive use of commercially available components and avoidance of complicated custom optics are key for quick and resource-efficient implementation.

  6. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, I.; Huppert, M.; Wörner, H. J., E-mail: hwoerner@ethz.ch [Laboratory of Physical Chemistry, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich (Switzerland); Brown, M. A. [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, Vladimir-Prelog-Weg 5, 8093 Zurich (Switzerland); Bokhoven, J. A. van [Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zurich (Switzerland); Laboratory for Catalysis and Sustainable Chemistry, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2015-12-15

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  7. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    International Nuclear Information System (INIS)

    Jordan, I.; Huppert, M.; Wörner, H. J.; Brown, M. A.; Bokhoven, J. A. van

    2015-01-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup

  8. Photoelectron spectrometer for attosecond spectroscopy of liquids and gases

    Science.gov (United States)

    Jordan, I.; Huppert, M.; Brown, M. A.; van Bokhoven, J. A.; Wörner, H. J.

    2015-12-01

    A new apparatus for attosecond time-resolved photoelectron spectroscopy of liquids and gases is described. It combines a liquid microjet source with a magnetic-bottle photoelectron spectrometer and an actively stabilized attosecond beamline. The photoelectron spectrometer permits venting and pumping of the interaction chamber without affecting the low pressure in the flight tube. This pressure separation has been realized through a sliding skimmer plate, which effectively seals the flight tube in its closed position and functions as a differential pumping stage in its open position. A high-harmonic photon spectrometer, attached to the photoelectron spectrometer, exit port is used to acquire photon spectra for calibration purposes. Attosecond pulse trains have been used to record photoelectron spectra of noble gases, water in the gas and liquid states as well as solvated species. RABBIT scans demonstrate the attosecond resolution of this setup.

  9. A multi-parameter, acquisition system positron annihilation lifetime spectrometer

    International Nuclear Information System (INIS)

    Sharshar, T.

    2004-01-01

    A positron annihilation lifetime spectrometer employing a multi-parameter acquisition system has been prepared for various purposes such as the investigation and characterization of solid-state materials. The fast-fast coincidence technique was used in the present spectrometer with a pair of plastic scintillation detectors. The acquisition system is based on the Kmax software and on CAMAC modules. The data are acquired in event-by-event list mode. The time spectrum for the desired energy windows can be obtained by off-line data sorting and analysis. The spectrometer for event-by-event data acquisition is an important step to construct a positron age-momentum correlation (AMOC) spectrometer. The AMOC technique is especially suited for the observation of positron transitions between different states during their lifetime. The system performance was tested and the results were presented and discussed

  10. The development for small scale soft X-ray spectrometer

    International Nuclear Information System (INIS)

    Sun Kexu; Jiang Shaoen; Yi Rongqing; Cui Yanli

    2004-12-01

    For the development of small-scale soft X-ray spectrometer, first, some small-scale soft X-ray detection elements are developed, it is included GaAs irradiated with neutron, GaAs irradiated with proton, multi-layer mirror, plane mirror and small scale X-ray diode et al. Soft X-ray spectrometers built of multi-layer mirror-GaAs (with neutron irradiation), and plane mirror-small-scale XRD, and plane mirror-GaAs (with proton irradiation) are prepared. These spectrometers are examined in Shen Guang-II laser facility, and some external estimation are given. (authors)

  11. The OVIRS Visible/IR Spectrometer on the OSIRIS-Rex Mission

    Science.gov (United States)

    Reuter, D. C.; Simon-Miller, A. A.

    2012-01-01

    The OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security Regolith Explorer) Mission is a planetary science mission to study, and return a sample from, the carbonaceous asteroid 1999 RQ-36. The third mission selected under NASA's New Frontiers Program, it is scheduled to be launched in 2016. It is led by PI Dante Lauretta at the University of Arizona and managed by NASA's Goddard Space Flight Center. The spacecraft and the asteroid sampling mechanism, TAGSAM (Touch-And-Go Sample Acquisition Mechanism) will be provided by Lockheed Martin Space Systems. Instrumentation for studying the asteroid include: OCAMS (the OSIRIS-REx Camera Suite), OLA (the OSIRIS-REx Laser Altimeter, a scanning LIDAR), OTES (The OSIRIS-REx Thermal Emission Spectrometer, a 4-50 micron point spectrometer) and OVIRS (the OSIRIS-REx Visible and IR Spectrometer, a 0.4 to 4.3 micron point spectrometer). The payload also includes REXIS (the Regolith X-ray Imaging Spectrometer) a student provided experiment. This paper presents a description of the OVIRS instrument.

  12. Incremental Support Vector Machine Framework for Visual Sensor Networks

    Directory of Open Access Journals (Sweden)

    Yuichi Motai

    2007-01-01

    Full Text Available Motivated by the emerging requirements of surveillance networks, we present in this paper an incremental multiclassification support vector machine (SVM technique as a new framework for action classification based on real-time multivideo collected by homogeneous sites. The technique is based on an adaptation of least square SVM (LS-SVM formulation but extends beyond the static image-based learning of current SVM methodologies. In applying the technique, an initial supervised offline learning phase is followed by a visual behavior data acquisition and an online learning phase during which the cluster head performs an ensemble of model aggregations based on the sensor nodes inputs. The cluster head then selectively switches on designated sensor nodes for future incremental learning. Combining sensor data offers an improvement over single camera sensing especially when the latter has an occluded view of the target object. The optimization involved alleviates the burdens of power consumption and communication bandwidth requirements. The resulting misclassification error rate, the iterative error reduction rate of the proposed incremental learning, and the decision fusion technique prove its validity when applied to visual sensor networks. Furthermore, the enabled online learning allows an adaptive domain knowledge insertion and offers the advantage of reducing both the model training time and the information storage requirements of the overall system which makes it even more attractive for distributed sensor networks communication.

  13. Two-Point Incremental Forming with Partial Die: Theory and Experimentation

    Science.gov (United States)

    Silva, M. B.; Martins, P. A. F.

    2013-04-01

    This paper proposes a new level of understanding of two-point incremental forming (TPIF) with partial die by means of a combined theoretical and experimental investigation. The theoretical developments include an innovative extension of the analytical model for rotational symmetric single point incremental forming (SPIF), originally developed by the authors, to address the influence of the major operating parameters of TPIF and to successfully explain the differences in formability between SPIF and TPIF. The experimental work comprised the mechanical characterization of the material and the determination of its formability limits at necking and fracture by means of circle grid analysis and benchmark incremental sheet forming tests. Results show the adequacy of the proposed analytical model to handle the deformation mechanics of SPIF and TPIF with partial die and demonstrate that neck formation is suppressed in TPIF, so that traditional forming limit curves are inapplicable to describe failure and must be replaced by fracture forming limits derived from ductile damage mechanics. The overall geometric accuracy of sheet metal parts produced by TPIF with partial die is found to be better than that of parts fabricated by SPIF due to smaller elastic recovery upon unloading.

  14. Associated Particle Tagging (APT) in Magnetic Spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, David V.; Baciak, James E.; Stave, Sean C.; Chichester, David; Dale, Daniel; Kim, Yujong; Harmon, Frank

    2012-10-16

    Summary In Brief The Associated Particle Tagging (APT) project, a collaboration of Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL) and the Idaho State University (ISU)/Idaho Accelerator Center (IAC), has completed an exploratory study to assess the role of magnetic spectrometers as the linchpin technology in next-generation tagged-neutron and tagged-photon active interrogation (AI). The computational study considered two principle concepts: (1) the application of a solenoidal alpha-particle spectrometer to a next-generation, large-emittance neutron generator for use in the associated particle imaging technique, and (2) the application of tagged photon beams to the detection of fissile material via active interrogation. In both cases, a magnetic spectrometer momentum-analyzes charged particles (in the neutron case, alpha particles accompanying neutron generation in the D-T reaction; in the tagged photon case, post-bremsstrahlung electrons) to define kinematic properties of the relevant neutral interrogation probe particle (i.e. neutron or photon). The main conclusions of the study can be briefly summarized as follows: Neutron generator: • For the solenoidal spectrometer concept, magnetic field strengths of order 1 Tesla or greater are required to keep the transverse size of the spectrometer smaller than 1 meter. The notional magnetic spectrometer design evaluated in this feasibility study uses a 5-T magnetic field and a borehole radius of 18 cm. • The design shows a potential for 4.5 Sr tagged neutron solid angle, a factor of 4.5 larger than achievable with current API neutron-generator designs. • The potential angular resolution for such a tagged neutron beam can be less than 0.5o for modest Si-detector position resolution (3 mm). Further improvement in angular resolution can be made by using Si-detectors with better position resolution. • The report documents several features of a notional generator design incorporating the

  15. A comparative study of velocity increment generation between the rigid body and flexible models of MMET

    Energy Technology Data Exchange (ETDEWEB)

    Ismail, Norilmi Amilia, E-mail: aenorilmi@usm.my [School of Aerospace Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang (Malaysia)

    2016-02-01

    The motorized momentum exchange tether (MMET) is capable of generating useful velocity increments through spin–orbit coupling. This study presents a comparative study of the velocity increments between the rigid body and flexible models of MMET. The equations of motions of both models in the time domain are transformed into a function of true anomaly. The equations of motion are integrated, and the responses in terms of the velocity increment of the rigid body and flexible models are compared and analysed. Results show that the initial conditions, eccentricity, and flexibility of the tether have significant effects on the velocity increments of the tether.

  16. Development of cold neutron spectrometers

    International Nuclear Information System (INIS)

    Lee, Changhee; Lee, C. H.; So, J. Y.; Park, S.; Han, Y. S.; Cho, S. J.; Moon, M. K.; Choi, Y. H.; Sun, G. M.

    2012-03-01

    □ Cold Neutron Triple Axsis Spectrometer (Cold-TAS) Development Ο Fabrication and Installation of the Major Cold-TAS Components Ο Performance Test of the Cold-TAS □ Cold Neutron Time-of-Flight Spectrometer(DC-TOF) Development Ο Fabrication of the Major DC-TOF Components Ο Development DC-TOF Data Reduction Software □ Expected Contribution The two world-class inelastic neutron scattering instruments measure atomic or molecular scale dynamics of meV energy range. This unprecedented measurement capability in the country will enable domestic and international scientists to observe new phenomena in their materials research to obtain world class results. Especially those who work in the fields of magnetic properties of superconductors and multiferroics, molecular dynamics, etc. will get more benefit from these two instruments

  17. The Harwell back-scattering spectrometer

    International Nuclear Information System (INIS)

    Windsor, C.G.; Bunce, L.J.; Borcherds, P.H.; Cole, I.; Fitzmaurice, M.; Johnson, D.A.G.; Sinclair, R.N.

    1976-01-01

    Neutron diffraction spectra in which both high resolution (Δ Q/Q approximately equal to 0.003) and high intensity are maintained up to scattering vectors as high as 30A -1 (sin theta/lambda = 2.5) have been obtained with the back-scattering spectrometer (BSS) recently installed on the Harwell electron linac. The theory behind the spectrometer design is described, and it is shown how the above resolution requirement leads to its basic features of a 12m incident flight path, a 2m scattering flight path and a scattering angle (2theta) acceptance from 165 0 to 175 0 . Examples of the resolution, intensity and background are given. It is shown that the problem of frame overlap may be overcome by using an absorbing filter. (author)

  18. Mobile-phone-based home exercise training program decreases systemic inflammation in COPD: a pilot study.

    Science.gov (United States)

    Wang, Chun-Hua; Chou, Pai-Chien; Joa, Wen-Ching; Chen, Li-Fei; Sheng, Te-Fang; Ho, Shu-Chuan; Lin, Horng-Chyuan; Huang, Chien-Da; Chung, Fu-Tsai; Chung, Kian Fan; Kuo, Han-Pin

    2014-08-30

    Moderate-intensity exercise training improves skeletal muscle aerobic capacity and increased oxidative enzyme activity, as well as exercise tolerance in COPD patients. To investigate whether the home-based exercise training program can reduce inflammatory biomarkers in patients with COPD, twelve patients using mobile phone assistance and 14 with free walk were assessed by incremental shuttle walk test (ISWT), spirometry, strength of limb muscles, and serum C-reactive protein (CRP) and inflammatory cytokines. Patients in the mobile phone group improved their ISWT walking distance, with decrease in serum CRP after 2 months, and sustained at 6 months. Patients in the control group had no improvement. Serum IL-8 in the mobile phone group was significantly reduced at 2, 3 and 6 months after doing home exercise training compared to baseline. IL-6 and TNF-α were significantly elevated at 3 and 6 months in control group, while there were no changes in mobile phone group. The strength of limb muscles was significantly greater compared to baseline at 3 and 6 months in the mobile phone group. A mobile-phone-based system can provide an efficient home endurance exercise training program with improved exercise capacity, strength of limb muscles and a decrease in serum CRP and IL-8 in COPD patients. Decreased systemic inflammation may contribute to these clinical benefits. (Clinical trial registration No.: NCT01631019).

  19. Evolving effective incremental SAT solvers with GP

    OpenAIRE

    Bader, Mohamed; Poli, R.

    2008-01-01

    Hyper-Heuristics could simply be defined as heuristics to choose other heuristics, and it is a way of combining existing heuristics to generate new ones. In a Hyper-Heuristic framework, the framework is used for evolving effective incremental (Inc*) solvers for SAT. We test the evolved heuristics (IncHH) against other known local search heuristics on a variety of benchmark SAT problems.

  20. GEANT Monte Carlo simulations for the GREAT spectrometer

    International Nuclear Information System (INIS)

    Andreyev, A.N.; Butler, P.A.; Page, R.D.; Appelbe, D.E.; Jones, G.D.; Joss, D.T.; Herzberg, R.-D.; Regan, P.H.; Simpson, J.; Wadsworth, R.

    2004-01-01

    GEANT Monte Carlo simulations for the recently developed GREAT spectrometer are presented. Some novel applications of the spectrometer for γ-ray, conversion-electron and β-decay spectroscopy are discussed. The conversion-electron spectroscopy of heavy nuclei with strongly converted transitions and the extension of the recoil decay tagging method to β-decaying nuclei are considered in detail

  1. Theoretical resolving power of a radiofrequency mass spectrometer

    International Nuclear Information System (INIS)

    Coc, A.; Le Gac, R.; Saint Simon, M. de; Thibault, C.; Touchard, F.

    1988-01-01

    Radiofrequency mass spectrometers of L.G. Smith's type can reach a resolving power of 10 6 -10 7 and a precision of 10 -9 -10 -10 . The resolving power, shape of peaks and limitations are described. As an example, the spectrometer to be used in an experiment aimed at measuring the anti p/p mass ratio is considered. (orig.)

  2. Noise considerations in millimeter-wave spectrometers

    International Nuclear Information System (INIS)

    Zoellner, W.D.; Kolbe, W.F.; Leskovar, B.

    1978-12-01

    An improved version of a microwave spectrometer operating in the vicinity of 70 GHz is described. The spectrometer, which incorporates a Fabry-Perot resonator and superheterodyne detection for high sensitivity is designed for the detection of gaseous pollutants and other atmospheric constituents. The instrument is capable of detecting polar molecules with absorption coefficients as small as 2 x 10 -9 cm -1 . For sulphur dioxide diluted in air, this sensitivity corresponds to a detection limit of 1.2 ppm without preconcentration and with a time constant of 1 second. Measurements and analysis of the noise contributions limiting the sentivity are presented

  3. Streaked, x-ray-transmission-grating spectrometer

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Roth, M.; Hawryluk, A.M.

    1981-08-01

    A free standing x-ray transmission grating has been coupled with a soft x-ray streak camera to produce a time resolved x-ray spectrometer. The instrument has a temporal resolution of approx. 20 psec, is capable of covering a broad spectral range, 2 to 120 A, has high sensitivity, and is simple to use requiring no complex alignment procedure. In recent laser fusion experiments the spectrometer successfully recorded time resolved spectra over the range 10 to 120 A with a spectral resolving power, lambda/Δlambda of 4 to 50, limited primarily by source size and collimation effects

  4. Highly effective portable beta spectrometer for precise depth selective electron Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Aldiyarov, N.U.; Kadyrzhanov, K.K.; Seytimbetov, A.M.; Zhdanov, V.S.

    2007-01-01

    Full text: More broad application of the nuclear-physical method of precise Depth Selective Electron Moessbauer Spectroscopy (DS EMS) is limited by insufficient accessibility of highly-effective beta spectrometers with acceptable resolution. It should be mentioned that the method DS EMS is realized at a combined installation that consists of a highly-effective beta spectrometer and a conventional portable nuclear gamma-resonance spectrometer. Yet few available beta spectrometers have sophisticated design and controlling; in most cases they are cumbersome. All the attempts to simplify beta spectrometers resulted in noticeable worsening of depth resolution for the DS EMS method making the measurements non precise. There is currently an obvious need in a highly-effective portable easily controlled beta spectrometer. While developing such portable beta spectrometer, it is more promising to use as basis a simpler spectrometer, which has ratio of sample size to spectrometer size of about five times. The paper presents an equal-arm version of a highly-effective portable beta spectrometer with transverse heterogeneous sector magnetic field that assures double focusing. The spectrometer is equipped with a large-area non-equipotential source (a sample under investigation) and a position-sensitive detector. This portable spectrometer meets all requirements for achievement of the DS EMS depth resolution close to the physical limit and demonstrates the following main characteristics: equilibrium orbit radius ρ 0 = 80 mm, instrumental energy resolution 0.6 % at solid angle 1 % of 4π steradian, area of non-equipotential source ∼ 80 mm 2 , registration by position-sensitive detector of ∼ 10 % of the energy interval. Highly-effective portable beta spectrometer assures obtaining Moessbauer data with depth resolution close to physical limit of the DS EMS method. So in measurements at conversion and Auger electrons with energies of about units of keV and above, the achieved

  5. Real Time Implementation of Incremental Fuzzy Logic Controller for Gas Pipeline Corrosion Control

    Directory of Open Access Journals (Sweden)

    Gopalakrishnan Jayapalan

    2014-01-01

    Full Text Available A robust virtual instrumentation based fuzzy incremental corrosion controller is presented to protect metallic gas pipelines. Controller output depends on error and change in error of the controlled variable. For corrosion control purpose pipe to soil potential is considered as process variable. The proposed fuzzy incremental controller is designed using a very simple control rule base and the most natural and unbiased membership functions. The proposed scheme is tested for a wide range of pipe to soil potential control. Performance comparison between the conventional proportional integral type and proposed fuzzy incremental controller is made in terms of several performance criteria such as peak overshoot, settling time, and rise time. Result shows that the proposed controller outperforms its conventional counterpart in each case. Designed controller can be taken in automode without waiting for initial polarization to stabilize. Initial startup curve of proportional integral controller and fuzzy incremental controller is reported. This controller can be used to protect any metallic structures such as pipelines, tanks, concrete structures, ship, and offshore structures.

  6. Development of gamma spectrometer using silicon photomultiplier (SiPM)

    International Nuclear Information System (INIS)

    Kim, Chan Kyu

    2011-02-01

    Gamma spectroscopy is used to determine the identity and quantity of gamma-emitters in nuclear physics, geochemistry and astrophysics. The scintillation detectors are being used as a gamma spectrometer generally, because of their higher gamma-ray detection efficiency and cheaper price than germanium semi-conductor detectors. A typical scintillation detector is composed of a scintillator, a window, and a photodetector. The photomultiplier (PM) tube has been the most widely used as a photodetector because of its advantages like high sensitivity, high signal-to-noise ratio, and wide dynamic range. Recently, the Silicon Photomultiplier (SiPM) is being studied as a substitute of PM tube. The SiPM has almost same performance compared to PM tube but it has additional advantages; low operating voltage, small volume, and cheap production cost. In this research, the gamma spectrometer using SiPM instead of PM tube is developed. The use of SiPM as a photodetector makes the gamma spectrometer smaller, cheaper, easier to use. For photon transport and collection from the large area scintillator to the small area SiPM, a light guide is applied in this gamma spectrometer system. Before fabrication of light guide, DETECT simulation is performed to study and prospect characteristics of light guide structure. And actual light guides are fabricated on the basis of this simulation result. Poly(methyl methacrylate) (PMMA) is chosen as material of light guide, 5 sample light guides are fabricated in different lengths and coatings. As a scintillator crystal, same NaI(Tl) crystal is chosen. For measurement and analysis of gamma spectrometer system, 3 gamma spectrometer systems are composed: PM tube-based system, PM tube-based system with the light guide, SiPM-based system with the light guide. Through comparison between the results of each gamma spectrometer, the performances of gamma spectrometer system are analyzed by each component. Measurement results of the second system is well

  7. Elements of Tiny Plasma Spectrometers

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to advance major elements of a miniaturized plasma spectrometer for flight on future missions. This type of instrument has been developed and successfully...

  8. The Lise spectrometer at Ganil

    International Nuclear Information System (INIS)

    Saint-Laurent, M.G.

    1986-08-01

    The doubly achromatic spectrometer LISE is available at the french national heavy ion accelerator GANIL. Experimental results, obtained in radioactive beam production and search for new exotic nuclei are briefly reported

  9. Minimizing System Modification in an Incremental Design Approach

    DEFF Research Database (Denmark)

    Pop, Paul; Eles, Petru; Pop, Traian

    2001-01-01

    In this paper we present an approach to mapping and scheduling of distributed embedded systems for hard real-time applications, aiming at minimizing the system modification cost. We consider an incremental design process that starts from an already existing sys-tem running a set of applications. We...

  10. EFFECT OF COST INCREMENT DISTRIBUTION PATTERNS ON THE PERFORMANCE OF JIT SUPPLY CHAIN

    Directory of Open Access Journals (Sweden)

    Ayu Bidiawati J.R

    2008-01-01

    Full Text Available Cost is an important consideration in supply chain (SC optimisation. This is due to emphasis placed on cost reduction in order to optimise profit. Some researchers use cost as one of their performance measures and others propose ways of accurately calculating cost. As product moves across SC, the product cost also increases. This paper studied the effect of cost increment distribution patterns on the performance of a JIT Supply Chain. In particular, it is necessary to know if inventory allocation across SC needs to be modified to accommodate different cost increment distribution patterns. It was found that funnel is still the best card distribution pattern for JIT-SC regardless the cost increment distribution patterns used.

  11. Tracking mobile users in wireless networks via semi-supervised colocalization.

    Science.gov (United States)

    Pan, Jeffrey Junfeng; Pan, Sinno Jialin; Yin, Jie; Ni, Lionel M; Yang, Qiang

    2012-03-01

    Recent years have witnessed the growing popularity of sensor and sensor-network technologies, supporting important practical applications. One of the fundamental issues is how to accurately locate a user with few labeled data in a wireless sensor network, where a major difficulty arises from the need to label large quantities of user location data, which in turn requires knowledge about the locations of signal transmitters or access points. To solve this problem, we have developed a novel machine learning-based approach that combines collaborative filtering with graph-based semi-supervised learning to learn both mobile users' locations and the locations of access points. Our framework exploits both labeled and unlabeled data from mobile devices and access points. In our two-phase solution, we first build a manifold-based model from a batch of labeled and unlabeled data in an offline training phase and then use a weighted k-nearest-neighbor method to localize a mobile client in an online localization phase. We extend the two-phase colocalization to an online and incremental model that can deal with labeled and unlabeled data that come sequentially and adapt to environmental changes. Finally, we embed an action model to the framework such that additional kinds of sensor signals can be utilized to further boost the performance of mobile tracking. Compared to other state-of-the-art systems, our framework has been shown to be more accurate while requiring less calibration effort in our experiments performed on three different testbeds.

  12. BMI and BMI SDS in childhood: annual increments and conditional change.

    Science.gov (United States)

    Brannsether, Bente; Eide, Geir Egil; Roelants, Mathieu; Bjerknes, Robert; Júlíusson, Pétur Benedikt

    2017-02-01

    Background Early detection of abnormal weight gain in childhood may be important for preventive purposes. It is still debated which annual changes in BMI should warrant attention. Aim To analyse 1-year increments of Body Mass Index (BMI) and standardised BMI (BMI SDS) in childhood and explore conditional change in BMI SDS as an alternative method to evaluate 1-year changes in BMI. Subjects and methods The distributions of 1-year increments of BMI (kg/m 2 ) and BMI SDS are summarised by percentiles. Differences according to sex, age, height, weight, initial BMI and weight status on the BMI and BMI SDS increments were assessed with multiple linear regression. Conditional change in BMI SDS was based on the correlation between annual BMI measurements converted to SDS. Results BMI increments depended significantly on sex, height, weight and initial BMI. Changes in BMI SDS depended significantly only on the initial BMI SDS. The distribution of conditional change in BMI SDS using a two-correlation model was close to normal (mean = 0.11, SD = 1.02, n = 1167), with 3.2% (2.3-4.4%) of the observations below -2 SD and 2.8% (2.0-4.0%) above +2 SD. Conclusion Conditional change in BMI SDS can be used to detect unexpected large changes in BMI SDS. Although this method requires the use of a computer, it may be clinically useful to detect aberrant weight development.

  13. The OPERA magnetic spectrometer

    CERN Document Server

    Ambrosio, M; Dusini, S; Dulach, B; Fanin, C; Felici, G; Corso, F D; Garfagnini, A; Grianti, F; Gustavino, C; Monacelli, P; Paoloni, A; Stanco, L; Spinetti, M; Terranova, F; Votano, L

    2004-01-01

    The OPERA neutrino oscillation experiment foresees the construction of two magnetized iron spectrometers located after the lead-nuclear emulsion targets. The magnet is made up of two vertical walls of rectangular cross section connected by return yokes. The particle trajectories are measured by high precision drift tubes located before and after the arms of the magnet. Moreover, the magnet steel is instrumented with Resistive Plate Chambers that ease pattern recognition and allow a calorimetric measurement of the hadronic showers. In this paper we review the construction of the spectrometers. In particular, we describe the results obtained from the magnet and RPC prototypes and the installation of the final apparatus at the Gran Sasso laboratories. We discuss the mechanical and magnetic properties of the steel and the techniques employed to calibrate the field in the bulk of the magnet. Moreover, results of the tests and issues concerning the mass production of the Resistive Plate Chambers are reported. Final...

  14. The SPEDE electron spectrometer

    CERN Document Server

    O'Neill, George

    This thesis presents SPEDE (SPectrometer for Electron DEtection) and documents its construction, testing and performance during commissioning at Jyvaskyla, Finland, before deployment at the HIE-ISOLDE facility at CERN coupled with the MINIBALL array to perform in-beam electron-gamma spectroscopy using post-accelerated radioactive ion beams. Commissioning experiments took place in two two-day stints during spring 2015, coupled with several JUROGAMII gamma-detectors. This spectrometer will help aid in fully understanding exotic regions of the nuclear chart such as regions with a high degree of octupole deformation, and in those nuclei exhibiting shape coexistence. For the rst time, electron spectroscopy has been performed at the target position from states populated in accelerated nuclei via Coulomb excitation. The FWHM of SPEDE is approximately 7 keV at 320 keV, and Doppler correction was possible to improve Doppler broadened peaks. The results are intended to give the reader a full understanding of the dete...

  15. A low-volume cavity ring-down spectrometer for sample-limited applications

    Science.gov (United States)

    Stowasser, C.; Farinas, A. D.; Ware, J.; Wistisen, D. W.; Rella, C.; Wahl, E.; Crosson, E.; Blunier, T.

    2014-08-01

    In atmospheric and environmental sciences, optical spectrometers are used for the measurements of greenhouse gas mole fractions and the isotopic composition of water vapor or greenhouse gases. The large sample cell volumes (tens of milliliters to several liters) in commercially available spectrometers constrain the usefulness of such instruments for applications that are limited in sample size and/or need to track fast variations in the sample stream. In an effort to make spectrometers more suitable for sample-limited applications, we developed a low-volume analyzer capable of measuring mole fractions of methane and carbon monoxide based on a commercial cavity ring-down spectrometer. The instrument has a small sample cell (9.6 ml) and can selectively be operated at a sample cell pressure of 140, 45, or 20 Torr (effective internal volume of 1.8, 0.57, and 0.25 ml). We present the new sample cell design and the flow path configuration, which are optimized for small sample sizes. To quantify the spectrometer's usefulness for sample-limited applications, we determine the renewal rate of sample molecules within the low-volume spectrometer. Furthermore, we show that the performance of the low-volume spectrometer matches the performance of the standard commercial analyzers by investigating linearity, precision, and instrumental drift.

  16. Relating annual increments of the endangered Blanding's turtle plastron growth to climate.

    Science.gov (United States)

    Richard, Monik G; Laroque, Colin P; Herman, Thomas B

    2014-05-01

    This research is the first published study to report a relationship between climate variables and plastron growth increments of turtles, in this case the endangered Nova Scotia Blanding's turtle (Emydoidea blandingii). We used techniques and software common to the discipline of dendrochronology to successfully cross-date our growth increment data series, to detrend and average our series of 80 immature Blanding's turtles into one common chronology, and to seek correlations between the chronology and environmental temperature and precipitation variables. Our cross-dated chronology had a series intercorrelation of 0.441 (above 99% confidence interval), an average mean sensitivity of 0.293, and an average unfiltered autocorrelation of 0.377. Our master chronology represented increments from 1975 to 2007 (33 years), with index values ranging from a low of 0.688 in 2006 to a high of 1.303 in 1977. Univariate climate response function analysis on mean monthly air temperature and precipitation values revealed a positive correlation with the previous year's May temperature and current year's August temperature; a negative correlation with the previous year's October temperature; and no significant correlation with precipitation. These techniques for determining growth increment response to environmental variables should be applicable to other turtle species and merit further exploration.

  17. Semiconductor X-ray spectrometer with light feedback

    International Nuclear Information System (INIS)

    Zubareva, A.M.; Iliev, S.; Kushniruk, V.F.; Rykhlyuk, A.V.; Subbotin, V.G.; Kharitonov, Yu.P.

    1978-01-01

    An X-ray spectrometer has been designed consisting of a preamplifier with light pulse feedback, and a Si (Li) detector. The electric(FET) circuit is given of the preamplifier designed on field effect transistors. An identification is made of the types of noises of a sink current of 7.5 mA. It is established that a significant part of the total noise comes from the detector-FET system, and white noise from leakage current in the detector. The use in the spectrometer of the preamplifier with light pulse feedback enables the white noise to be reduced to 40-45 eV with a detector leakage current of 10 -13 A. A decrease in the noise of the detector-FET system is only possible owing to the improved technology in the manufacture of FET's. The energy resolution of the spectrometer for the 5.9 keV line is 168 eV

  18. Partial pressure measurements with an active spectrometer

    International Nuclear Information System (INIS)

    Brooks, N.H.; Jensen, T.H.; Colchin, R.J.; Maingi, R.; Wade, M.R.; Finkenthal, D.F.; Naumenko, N.; Tugarinov, S.

    1998-07-01

    Partial pressure neutral ga measurements have been made using a commercial Penning gauge in conjunction with an active spectrometer. In prior work utilizing bandpass filters and conventional spectrometers, trace concentrations of the hydrogen isotopes H, D, T and of the noble gases He, Ne and Ar were determined from characteristic spectral lines in the light emitted by the neutral species of these elements. For all the elements mentioned, the sensitivity was limited by spectral contamination from a pervasive background of molecular hydrogen radiation. The active spectrometer overcomes this limitations by means of a digital lock-in method and correlation with reference spectra. Preliminary measurements of an admixture containing a trace amount of neon in deuterium show better than a factor of 20 improvement in sensitivity over conventional techniques. This can be further improved by correlating the relative intensities of multiple lines to sets of reference spectra

  19. Incremental Validity of the Trait Emotional Intelligence Questionnaire-Short Form (TEIQue-SF).

    Science.gov (United States)

    Siegling, A B; Vesely, Ashley K; Petrides, K V; Saklofske, Donald H

    2015-01-01

    This study examined the incremental validity of the adult short form of the Trait Emotional Intelligence Questionnaire (TEIQue-SF) in predicting 7 construct-relevant criteria beyond the variance explained by the Five-factor model and coping strategies. Additionally, the relative contributions of the questionnaire's 4 subscales were assessed. Two samples of Canadian university students completed the TEIQue-SF, along with measures of the Big Five, coping strategies (Sample 1 only), and emotion-laden criteria. The TEIQue-SF showed consistent incremental effects beyond the Big Five or the Big Five and coping strategies, predicting all 7 criteria examined across the 2 samples. Furthermore, 2 of the 4 TEIQue-SF subscales accounted for the measure's incremental validity. Although the findings provide good support for the validity and utility of the TEIQue-SF, directions for further research are emphasized.

  20. Charged-particle magnetic-quadrupole spectrometer for neutron induced reactions

    International Nuclear Information System (INIS)

    Haight, R.C.; Grimes, S.M.; Tuckey, B.J.; Anderson, J.D.

    1975-01-01

    A spectrometer has been developed for measuring the charged particle production cross sections and spectra in neutron-induced reactions. The spectrometer consists of a magnetic quadrupole doublet which focuses the charged particles onto a silicon surface barrier detector telescope which is 2 meters or more from the irradiated sample. Collimators, shielding, and the large source-to-detector distance reduce the background enough to use the spectrometer with a 14-MeV neutron source producing 4 . 10 12 n/s. The spectrometer has been used in investigations of proton, deuteron, and alpha particle production by 14-MeV neutrons incident on various materials. Protons with energies as low as 1.1 MeV have been measured. The good resolution of the detectors has also made possible an improved measurement of the neutron- neutron scattering length from the 0 0 proton spectrum from deuteron breakup by 14-MeV neutrons

  1. Learning in Different Modes: The Interaction Between Incremental and Radical Change

    DEFF Research Database (Denmark)

    Petersen, Anders Hedegaard; Boer, Harry; Gertsen, Frank

    2004-01-01

    The objective of the study presented in this article is to contribute to the development of theory on continuous innovation, i.e. the combination of operationally effective exploitation and strategically flexible exploration. A longitudinal case study is presented of the interaction between...... incremental and radical change in Danish company, observed through the lens of organizational learning. The radical change process is described in five phases, each of which had its own effects on incremental change initiatives in the company. The research identified four factors explaining these effects, all...

  2. Incremental Approach to the Technology of Test Design for Industrial Projects

    Directory of Open Access Journals (Sweden)

    P. D. Drobintsev

    2014-01-01

    Full Text Available The paper presents an approach to effort reduction in developing test suites for industrial software products based on the incremental technology. The main problems to be solved by the incremental technology are full automation design of test scenarios and significant reducing of test explosion. The proposed approach provides solutions to the mentioned problems through joint co-working of a designer and a customer, through the integration of symbolic verification with the automatic generation of test suites; through the usage of an efficient technology with the toolset VRS/TAT.

  3. Two models of minimalist, incremental syntactic analysis.

    Science.gov (United States)

    Stabler, Edward P

    2013-07-01

    Minimalist grammars (MGs) and multiple context-free grammars (MCFGs) are weakly equivalent in the sense that they define the same languages, a large mildly context-sensitive class that properly includes context-free languages. But in addition, for each MG, there is an MCFG which is strongly equivalent in the sense that it defines the same language with isomorphic derivations. However, the structure-building rules of MGs but not MCFGs are defined in a way that generalizes across categories. Consequently, MGs can be exponentially more succinct than their MCFG equivalents, and this difference shows in parsing models too. An incremental, top-down beam parser for MGs is defined here, sound and complete for all MGs, and hence also capable of parsing all MCFG languages. But since the parser represents its grammar transparently, the relative succinctness of MGs is again evident. Although the determinants of MG structure are narrowly and discretely defined, probabilistic influences from a much broader domain can influence even the earliest analytic steps, allowing frequency and context effects to come early and from almost anywhere, as expected in incremental models. Copyright © 2013 Cognitive Science Society, Inc.

  4. Towards Reliable and Energy-Efficient Incremental Cooperative Communication for Wireless Body Area Networks.

    Science.gov (United States)

    Yousaf, Sidrah; Javaid, Nadeem; Qasim, Umar; Alrajeh, Nabil; Khan, Zahoor Ali; Ahmed, Mansoor

    2016-02-24

    In this study, we analyse incremental cooperative communication for wireless body area networks (WBANs) with different numbers of relays. Energy efficiency (EE) and the packet error rate (PER) are investigated for different schemes. We propose a new cooperative communication scheme with three-stage relaying and compare it to existing schemes. Our proposed scheme provides reliable communication with less PER at the cost of surplus energy consumption. Analytical expressions for the EE of the proposed three-stage cooperative communication scheme are also derived, taking into account the effect of PER. Later on, the proposed three-stage incremental cooperation is implemented in a network layer protocol; enhanced incremental cooperative critical data transmission in emergencies for static WBANs (EInCo-CEStat). Extensive simulations are conducted to validate the proposed scheme. Results of incremental relay-based cooperative communication protocols are compared to two existing cooperative routing protocols: cooperative critical data transmission in emergencies for static WBANs (Co-CEStat) and InCo-CEStat. It is observed from the simulation results that incremental relay-based cooperation is more energy efficient than the existing conventional cooperation protocol, Co-CEStat. The results also reveal that EInCo-CEStat proves to be more reliable with less PER and higher throughput than both of the counterpart protocols. However, InCo-CEStat has less throughput with a greater stability period and network lifetime. Due to the availability of more redundant links, EInCo-CEStat achieves a reduced packet drop rate at the cost of increased energy consumption.

  5. High-resolution spectrometer at PEP

    International Nuclear Information System (INIS)

    Weiss, J.M.; HRS Collaboration.

    1982-01-01

    A description is presented of the High Resolution Spectrometer experiment (PEP-12) now running at PEP. The advanced capabilities of the detector are demonstrated with first physics results expected in the coming months

  6. An improved computer controlled triple-axis neutron spectrometer

    International Nuclear Information System (INIS)

    Cooper, M.J.; Hall, J.W.; Hutchings, M.T.

    1975-07-01

    A description is given of the computer-controlled triple-axis neutron spectrometer installed at the PLUTO reactor at Harwell. The reasons for an nature of recent major improvements are discussed. Following a general description of the spectrometer, details are then given of the new computerised control system, including the functions of the various programs which are now available to the user. (author)

  7. Automation, development and performance of a photoacoustic spectrometer

    International Nuclear Information System (INIS)

    Cavalheiro, F.R.F.

    1985-01-01

    This work consists in the development of a circuit to interface a photoacoustic spectrometer with a microcomputer. The obtained spectra are identical to those obtained in commercial photoacoustic spectrometers. The system permits a great versatility and it has possibilities to automatize other types of experiments. The system can be duplicated from national components and at a relatively low coast. (author)

  8. A new small-angle neutron scattering spectrometer at China Mianyang research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Mei, E-mail: pm740509@163.com; Sun, Liangwei; Chen, Liang; Sun, Guangai; Chen, Bo; Xie, Chaomei; Xia, Qingzhong; Yan, Guanyun; Tian, Qiang; Huang, Chaoqiang; Pang, Beibei; Zhang, Ying; Wang, Yun; Liu, Yaoguang; Kang, Wu; Gong, Jian

    2016-02-21

    A new pinhole small-angle neutron scattering (SANS) spectrometer, installed at the cold neutron source of the 20 MW China Mianyang Research Reactor (CMRR) in the Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, has been put into use since 2014. The spectrometer is equipped with a multi-blade mechanical velocity selector, a multi-beam collimation system, and a two-dimensional He-3 position sensitive neutron detector. The q-range of the spectrometer covers from 0.01 nm{sup −1} to 5.0 nm{sup −1}. In this paper, the design and characteristics of the SANS spectrometer are described. The q-resolution calculations, together with calibration measurements of silver behenate and a dispersion of nearly monodisperse poly-methyl-methacrylate nanoparticles indicate that our SANS spectrometer has a good performance and is now in routine service. - Highlights: • A new SANS spectrometer has been put into use since 2014 in China. • One MBR selector possesses a higher resolution compared with traditional selector is used. • The spectrometer has a good performance and is now in routinely service.

  9. Lessons Learned for the MICE Coupling Solenoid from the MICE Spectrometer Solenoids

    International Nuclear Information System (INIS)

    Green, Michael A.; Wang, Li; Pan, Heng; Wu, Hong; Guo, Xinglong; Li, S.Y.; Zheng, S.X.; Virostek, Steve P.; DeMello, Allen J.; Li, Derun; Trillaud, Frederick; Zisman, Michael S.

    2010-01-01

    Tests of the spectrometer solenoids have taught us some important lessons. The spectrometer magnet lessons learned fall into two broad categories that involve the two stages of the coolers that are used to cool the magnets. On the first spectrometer magnet, the problems were centered on the connection of the cooler 2nd-stage to the magnet cold mass. On the first test of the second spectrometer magnet, the problems were centered on the cooler 1st-stage temperature and its effect on the operation of the HTS leads. The second time the second spectrometer magnet was tested; the cooling to the cold mass was still not adequate. The cryogenic designs of the MICE and MuCOOL coupling magnets are quite different, but the lessons learned from the tests of the spectrometer magnets have affected the design of the coupling magnets.

  10. Compact terahertz spectrometer based on disordered rough surfaces

    Science.gov (United States)

    Yang, Tao; Jiang, Bing; Ge, Jia-cheng; Zhu, Yong-yuan; Li, Xing-ao; Huang, Wei

    2018-01-01

    In this paper, a compact spectrometer based on disordered rough surfaces for operation in the terahertz band is presented. The proposed spectrometer consists of three components, which are used for dispersion, modulation and detection respectively. The disordered rough surfaces, which are acted as the dispersion component, are modulated by the modulation component. Different scattering intensities are captured by the detection component with different extent of modulation. With a calibration measurement process, one can reconstruct the spectra of the probe terahertz beam by solving a system of simultaneous linear equations. A Tikhonov regularization approach has been implemented to improve the accuracy of the spectral reconstruction. The reported broadband, compact, high-resolution terahertz spectrometer is well suited for portable terahertz spectroscopy applications.

  11. A Shuttle Upper Atmosphere Mass Spectrometer /SUMS/ experiment

    Science.gov (United States)

    Blanchard, R. C.; Duckett, R. J.; Hinson, E. W.

    1982-01-01

    A magnetic mass spectrometer is currently being adapted to the Space Shuttle Orbiter to provide repeated high altitude atmosphere data to support in situ rarefied flow aerodynamics research, i.e., in the high velocity, low density flight regime. The experiment, called Shuttle Upper Atmosphere Mass Spectrometer (SUMS), is the first attempt to design mass spectrometer equipment for flight vehicle aerodynamic data extraction. The SUMS experiment will provide total freestream atmospheric quantitites, principally total mass density, above altitudes at which conventional pressure measurements are valid. Experiment concepts, the expected flight profile, tradeoffs in the design of the total system and flight data reduction plans are discussed. Development plans are based upon a SUMS first flight after the Orbiter initial development flights.

  12. Inficon Transpector MPH Mass Spectrometer Random Vibration Test Report

    Science.gov (United States)

    Santiago-Bond, Jo; Captain, Janine

    2015-01-01

    The purpose of this test report is to summarize results from the vibration testing of the INFICON Transpector MPH100M model Mass Spectrometer. It also identifies requirements satisfied, and procedures used in the test. As a payload of Resource Prospector, it is necessary to determine the survivability of the mass spectrometer to proto-qualification level random vibration. Changes in sensitivity of the mass spectrometer can be interpreted as a change in alignment of the instrument. The results of this test will be used to determine any necessary design changes as the team moves forward with flight design.

  13. Design of airborne imaging spectrometer based on curved prism

    Science.gov (United States)

    Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao

    2011-11-01

    A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.

  14. Mobile Workforce, Mobile Technology, Mobile Threats

    International Nuclear Information System (INIS)

    Garcia, J.

    2015-01-01

    Mobile technologies' introduction into the world of safeguards business processes such as inspection creates tremendous opportunity for novel approaches and could result in a number of improvements to such processes. Mobile applications are certainly the wave of the future. The success of the application ecosystems has shown that users want full fidelity, highly-usable, simple purpose applications with simple installation, quick responses and, of course, access to network resources at all times. But the counterpart to opportunity is risk, and the widespread adoption of mobile technologies requires a deep understanding of the threats and vulnerabilities inherent in mobile technologies. Modern mobile devices can be characterized as small computers. As such, the threats against computing infrastructure apply to mobile devices. Meanwhile, the attributes of mobile technology that make it such an obvious benefit over traditional computing platforms all have elements of risk: pervasive, always-on networking; diverse ecosystems; lack of centralized control; constantly shifting technological foundations; intense competition among competitors in the marketplace; the scale of the installation base (from millions to billions); and many more. This paper will explore the diverse and massive environment of mobile, the number of attackers and vast opportunities for compromise. The paper will explain how mobile devices prove valuable targets to both advanced and persistent attackers as well as less-skilled casual hackers. Organized crime, national intelligence agencies, corporate espionage are all part of the landscape. (author)

  15. Beam analysis spectrometer for relativistic heavy ions

    International Nuclear Information System (INIS)

    Schimmerling, W.; Subramanian, T.S.; McDonald, W.J.; Kaplan, S.N.; Sadoff, A.; Gabor, G.

    1983-01-01

    A versatile spectrometer useful for measuring the mass, charge, energy, fluence and angular distribution of primaries and fragments associated with relativistic heavy ion beams is described. The apparatus is designed to provide accurate physical data for biology experiments and medical therapy planning as a function of depth in tissue. The spectrometer can also be used to measure W, the average energy to produce an ion pair, range-energy, dE/dx, and removal cross section data of interest in nuclear physics. (orig.)

  16. Electron spectrometers with internal conversion

    International Nuclear Information System (INIS)

    Suita, J.C.; Lemos Junior, O.F.; Auler, L.T.; Silva, A.G. da

    1981-01-01

    The efforts that the Department of Physics (DEFI) of Institute of Nuclear Engineering (IEN) are being made aiming at adjusting the electron spectrometers with internal conversion to its necessity, are shown. (E.G.) [pt

  17. Temporal Memory Reinforcement Learning for the Autonomous Micro-mobile Robot Based-behavior

    Institute of Scientific and Technical Information of China (English)

    Yang Yujun(杨玉君); Cheng Junshi; Chen Jiapin; Li Xiaohai

    2004-01-01

    This paper presents temporal memory reinforcement learning for the autonomous micro-mobile robot based-behavior. Human being has a memory oblivion process, i.e. the earlier to memorize, the earlier to forget, only the repeated thing can be remembered firmly. Enlightening forms this, and the robot need not memorize all the past states, at the same time economizes the EMS memory space, which is not enough in the MPU of our AMRobot. The proposed algorithm is an extension of the Q-learning, which is an incremental reinforcement learning method. The results of simulation have shown that the algorithm is valid.

  18. Effect of multiple forming tools on geometrical and mechanical properties in incremental sheet forming

    Science.gov (United States)

    Wernicke, S.; Dang, T.; Gies, S.; Tekkaya, A. E.

    2018-05-01

    The tendency to a higher variety of products requires economical manufacturing processes suitable for the production of prototypes and small batches. In the case of complex hollow-shaped parts, single point incremental forming (SPIF) represents a highly flexible process. The flexibility of this process comes along with a very long process time. To decrease the process time, a new incremental forming approach with multiple forming tools is investigated. The influence of two incremental forming tools on the resulting mechanical and geometrical component properties compared to SPIF is presented. Sheets made of EN AW-1050A were formed to frustums of a pyramid using different tool-path strategies. Furthermore, several variations of the tool-path strategy are analyzed. A time saving between 40% and 60% was observed depending on the tool-path and the radii of the forming tools while the mechanical properties remained unchanged. This knowledge can increase the cost efficiency of incremental forming processes.

  19. Exploiting a Transmission Grating Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Ronald E. Bell

    2004-12-08

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics.

  20. Exploiting a Transmission Grating Spectrometer

    International Nuclear Information System (INIS)

    Bell, Ronald E.

    2004-01-01

    The availability of compact transmission grating spectrometers now allows an attractive and economical alternative to the more familiar Czerny-Turner configuration for many high-temperature plasma applications. Higher throughput is obtained with short focal length refractive optics and stigmatic imaging. Many more spectra can be obtained with a single spectrometer since smaller, more densely packed optical input fibers can be used. Multiple input slits, along with a bandpass filter, can be used to maximize the number of spectra per detector, providing further economy. Curved slits can correct for the strong image curvature of the short focal length optics. Presented here are the governing grating equations for both standard and high-dispersion transmission gratings, defining dispersion, image curvature, and desired slit curvature, that can be used in the design of improved plasma diagnostics

  1. Polarized neutron spectrometer

    International Nuclear Information System (INIS)

    Abov, Yu.G.; Novitskij, V.V.; Alfimenkov, V.P.; Galinskij, E.M.; Mareev, Yu.D.; Pikel'ner, L.B.; Chernikov, A.N.; Lason', L.; Tsulaya, V.M.; Tsulaya, M.I.

    2000-01-01

    The polarized neutron spectrometer, intended for studying the interaction of polarized neutrons with nuclei and condensed media in the area of energies from thermal up to several electron-volt, is developed at the IBR-2 reactor (JINR, Dubna). Diffraction on the Co(92%)-Fe(8%) magnetized monocrystals is used for the neutron polarization and polarization analysis. The neutron polarization within the whole energy range equals ∼ 95% [ru

  2. Parallel Algorithm for Incremental Betweenness Centrality on Large Graphs

    KAUST Repository

    Jamour, Fuad Tarek; Skiadopoulos, Spiros; Kalnis, Panos

    2017-01-01

    : they either require excessive memory (i.e., quadratic to the size of the input graph) or perform unnecessary computations rendering them prohibitively slow. We propose iCentral; a novel incremental algorithm for computing betweenness centrality in evolving

  3. Incremental principal component pursuit for video background modeling

    Science.gov (United States)

    Rodriquez-Valderrama, Paul A.; Wohlberg, Brendt

    2017-03-14

    An incremental Principal Component Pursuit (PCP) algorithm for video background modeling that is able to process one frame at a time while adapting to changes in background, with a computational complexity that allows for real-time processing, having a low memory footprint and is robust to translational and rotational jitter.

  4. Geometry of finite deformations and time-incremental analysis

    Czech Academy of Sciences Publication Activity Database

    Fiala, Zdeněk

    2016-01-01

    Roč. 81, May (2016), s. 230-244 ISSN 0020-7462 Institutional support: RVO:68378297 Keywords : solid mechanics * finite deformations * time-incremental analysis * Lagrangian system * evolution equation of Lie type Subject RIV: BE - Theoretical Physics Impact factor: 2.074, year: 2016 http://www.sciencedirect.com/science/article/pii/S0020746216000330

  5. Incremental View Maintenance for Deductive Graph Databases Using Generalized Discrimination Networks

    Directory of Open Access Journals (Sweden)

    Thomas Beyhl

    2016-12-01

    Full Text Available Nowadays, graph databases are employed when relationships between entities are in the scope of database queries to avoid performance-critical join operations of relational databases. Graph queries are used to query and modify graphs stored in graph databases. Graph queries employ graph pattern matching that is NP-complete for subgraph isomorphism. Graph database views can be employed that keep ready answers in terms of precalculated graph pattern matches for often stated and complex graph queries to increase query performance. However, such graph database views must be kept consistent with the graphs stored in the graph database. In this paper, we describe how to use incremental graph pattern matching as technique for maintaining graph database views. We present an incremental maintenance algorithm for graph database views, which works for imperatively and declaratively specified graph queries. The evaluation shows that our maintenance algorithm scales when the number of nodes and edges stored in the graph database increases. Furthermore, our evaluation shows that our approach can outperform existing approaches for the incremental maintenance of graph query results.

  6. Description of the double Compton spectrometer at Mayence MPI

    International Nuclear Information System (INIS)

    Borchert, H.; Ziegler, B.; Gimm, H.; Zieger, A.; Hughes, R.J.; Ahrens, J.

    1977-01-01

    The double Compton spectrometer of the Laboratories of the Mayence Linear Accelerator consists in two identical magnetic spectrometers, in which the electron scattered forwards by photons through a Compton process, are detected. The spectrometers have been built to detect 10-350 MeV photons and, as they involve thin Compton targets, their effect on the photon flux is negligible. They are put in cascade inside a well collimated bremsstrahlung beam. A thick absorbing target (max. thickness 2m) can be inserted inside the beam. The facility is outlined, some special properties of the accelerator and the bremsstrahlung beam are given. The properties of a Compton spectrometer involving eleven detectors are given by eleven response functions giving the relations between the photon flux impinging the Compton target and the counting rates of the detectors for a given adjustment of the magnets. A Monte-Carlo method is used for the calculation together with analytical methods neglecting the multiple scattering effects [fr

  7. The University of Colorado OSO-8 spectrometer experiment. I

    International Nuclear Information System (INIS)

    Bruner, E.C. Jr.

    1977-01-01

    The optical design of the high resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft by the University of Colorado is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200 A to about 2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 sec normal to the direction of the slit and is selectable from about 3 sec to 15' along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer. In this paper the author develops the performance requirements of the spectrometer and attempts to highlight some of the tradeoffs available to the instrument designer. (Auth.)

  8. Optimal shape of a cold-neutron triple-axis spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Lefmann, K., E-mail: lefmann@fys.ku.d [Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen O (Denmark); European Spallation Source, University of Lund, St. Algatan 4, Lund (Sweden); Filges, U. [Laboratory for Development and Methods, Paul Scherrer Institute, 5232 Villigen PSI (Switzerland); Treue, F. [Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen O (Denmark); Kirkensgard, J.J.K. [Institute of Nature and Models, Roskilde University (Denmark); Department of Basic Sciences and Environment, Faculty of Life Sciences, University of Copenhagen (Denmark); Plesner, B. [Institute of Nature and Models, Roskilde University (Denmark); Hansen, K.S. [Institute of Nature and Models, Roskilde University (Denmark); Mid-Greenland High School, Nuuk, Greenland (Denmark); Kleno, K.H. [Nanoscience and eScience Centers, Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen O (Denmark); European Spallation Source, University of Lund, St. Algatan 4, Lund (Sweden)

    2011-04-01

    We have performed a McStas optimization of the primary spectrometer for a generic 40 m long, cold-neutron triple-axis spectrometer with a doubly focusing monochromator. The optimal design contains an elliptically focusing guide, a virtual source point before a low-grade PG monochromator, and non-equidistant focusing at the monochromator. The flux at 5 meV shows a gain factor 12 over the 'classical' design with a straight 12x3cm{sup 2}, m=2 guide and a vertically focusing PG monochromator. In addition, the energy resolution was found to be improved. This unexpectedly large design improvement agrees with the Liouville theorem and can be understood as the product of many smaller gain factors, combined with a more optimal utilization of the beam divergence within the guide. Our results may be relevant for a possible upgrade of a number of cold-neutron triple-axis spectrometers-and for a possible triple-axis spectrometer at the European Spallation Source.

  9. Final Safety Analysis Report (FSAR) for Building 332, Increment III

    Energy Technology Data Exchange (ETDEWEB)

    Odell, B. N.; Toy, Jr., A. J.

    1977-08-31

    This Final Safety Analysis Report (FSAR) supplements the Preliminary Safety Analysis Report (PSAR), dated January 18, 1974, for Building 332, Increment III of the Plutonium Materials Engineering Facility located at the Lawrence Livermore Laboratory (LLL). The FSAR, in conjunction with the PSAR, shows that the completed increment provides facilities for safely conducting the operations as described. These documents satisfy the requirements of ERDA Manual Appendix 6101, Annex C, dated April 8, 1971. The format and content of this FSAR complies with the basic requirements of the letter of request from ERDA San to LLL, dated March 10, 1972. Included as appendices in support of th FSAR are the Building 332 Operational Safety Procedure and the LLL Disaster Control Plan.

  10. Single spectrometer station for neutrino-tagging

    International Nuclear Information System (INIS)

    Nedyalkov, I.P.

    1984-01-01

    A neutrino tagging station built with respect to the following scheme is proposed. A beam of muons and kaons passes through a magnetic spectrometer, where the energy of each particle is measured. There are coordinate detectors behind the spectrometer in several planes, where the direction of the trajectory of a given particle is determined. Thus, mesons enter the decay point wth the known 4-momentum. Behind the decay point the direction of μ-meson generated by the decay of parent mesons is measured. It is shown that information is sufficient for determining the kind of parent particle (pion or kaon), the energy and the direction of trajectory of the neutrino

  11. Health level seven interoperability strategy: big data, incrementally structured.

    Science.gov (United States)

    Dolin, R H; Rogers, B; Jaffe, C

    2015-01-01

    Describe how the HL7 Clinical Document Architecture (CDA), a foundational standard in US Meaningful Use, contributes to a "big data, incrementally structured" interoperability strategy, whereby data structured incrementally gets large amounts of data flowing faster. We present cases showing how this approach is leveraged for big data analysis. To support the assertion that semi-structured narrative in CDA format can be a useful adjunct in an overall big data analytic approach, we present two case studies. The first assesses an organization's ability to generate clinical quality reports using coded data alone vs. coded data supplemented by CDA narrative. The second leverages CDA to construct a network model for referral management, from which additional observations can be gleaned. The first case shows that coded data supplemented by CDA narrative resulted in significant variances in calculated performance scores. In the second case, we found that the constructed network model enables the identification of differences in patient characteristics among different referral work flows. The CDA approach goes after data indirectly, by focusing first on the flow of narrative, which is then incrementally structured. A quantitative assessment of whether this approach will lead to a greater flow of data and ultimately a greater flow of structured data vs. other approaches is planned as a future exercise. Along with growing adoption of CDA, we are now seeing the big data community explore the standard, particularly given its potential to supply analytic en- gines with volumes of data previously not possible.

  12. A fast implementation of the incremental backprojection algorithms for parallel beam geometries

    International Nuclear Information System (INIS)

    Chen, C.M.; Wang, C.Y.; Cho, Z.H.

    1996-01-01

    Filtered-backprojection algorithms are the most widely used approaches for reconstruction of computed tomographic (CT) images, such as X-ray CT and positron emission tomographic (PET) images. The Incremental backprojection algorithm is a fast backprojection approach based on restructuring the Shepp and Logan algorithm. By exploiting interdependency (position and values) of adjacent pixels, the Incremental algorithm requires only O(N) and O(N 2 ) multiplications in contrast to O(N 2 ) and O(N 3 ) multiplications for the Shepp and Logan algorithm in two-dimensional (2-D) and three-dimensional (3-D) backprojections, respectively, for each view, where N is the size of the image in each dimension. In addition, it may reduce the number of additions for each pixel computation. The improvement achieved by the Incremental algorithm in practice was not, however, as significant as expected. One of the main reasons is due to inevitably visiting pixels outside the beam in the searching flow scheme originally developed for the Incremental algorithm. To optimize implementation of the Incremental algorithm, an efficient scheme, namely, coded searching flow scheme, is proposed in this paper to minimize the overhead caused by searching for all pixels in a beam. The key idea of this scheme is to encode the searching flow for all pixels inside each beam. While backprojecting, all pixels may be visited without any overhead due to using the coded searching flow as the a priori information. The proposed coded searching flow scheme has been implemented on a Sun Sparc 10 and a Sun Sparc 20 workstations. The implementation results show that the proposed scheme is 1.45--2.0 times faster than the original searching flow scheme for most cases tested

  13. Increment and mortality in a virgin Douglas-fir forest.

    Science.gov (United States)

    Robert W. Steele; Norman P. Worthington

    1955-01-01

    Is there any basis to the forester's rule of thumb that virgin forests eventually reach an equilibrium where increment and mortality approximately balance? Are we wasting potential timber volume by failing to salvage mortality in old-growth stands?

  14. Linear Fresnel Spectrometer Chip with Gradient Line Grating

    Science.gov (United States)

    Choi, Sang Hyouk (Inventor); Park, Yeonjoon (Inventor)

    2015-01-01

    A spectrometer that includes a grating that disperses light via Fresnel diffraction according to wavelength onto a sensing area that coincides with an optical axis plane of the grating. The sensing area detects the dispersed light and measures the light intensity associated with each wavelength of the light. Because the spectrometer utilizes Fresnel diffraction, it can be miniaturized and packaged as an integrated circuit.

  15. Wide-aperture magnetic spectrometer with face position of MWPC

    International Nuclear Information System (INIS)

    Avakyan, R.O.; Avetisyan, A.Eh.; Ajvazyan, R.B.; Asaturyan, R.A.; Dallakyan, K.R.; Kizogyan, O.S.; Matevosyan, Eh.M.; Sukiasyan, Yu.Z.; Taroyan, S.P.

    1988-01-01

    A pair magnetic spectrometer with automated wire chambers for studying electron and positron interactions with monocrystals at the Erevan synchrotron is described. As a working gas the argon-methane mixture with methylal vapor addition is used. Results of modelling and experiments with spectrometer are presented. 2 refs.; 6 figs

  16. The full automation of a Philips 1220 x-ray spectrometer

    International Nuclear Information System (INIS)

    Austen, C.E.

    1976-01-01

    A Philips 1220 X-ray spectrometer (semi-automatic) was fully automated by the addition of a custom-built automatic sample-loader constructed at the National Institute for Metallurgy and a Texas 980 A mini-computer. The mini-computer was interfaced to the existing control circuits of the X-ray spectrometer through a custom-built logic-circuit unit that controls the automatic sample-loader and X-ray spectrometer on instructions received from the mini-computer. The controlling software is written in BASIC

  17. Diagnostic value of triphasic incremental helical CT in early and progressive gastric carcinoma

    International Nuclear Information System (INIS)

    Gao Jianbo; Yan Xuehua; Li Mengtai; Guo Hua; Chen Xuejun; Guan Sheng; Zhang Xiefu; Li Shuxin; Yang Xiaopeng

    2001-01-01

    Objective: To investigate helical CT enhancement characteristics of gastric carcinoma, and the diagnostic value and preoperative staging of gastric carcinoma with triphasic incremental helical CT of the stomach with water-filling method. Methods: Both double-contrast barium examination and triphasic incremental helical CT of the stomach with water-filling method were performed in 46 patients with gastric carcinoma. Results: (1) Among these patients, normal gastric wall exhibited one layered structure in 18 patients, two or three layered structure in 28 patients in the arterial and portal venous phase. (2) Two cases of early stomach cancer showed marked enhancement in the arterial and portal venous phase and obvious attenuation of enhancement in the equilibrium phase. On the contrary, 32 of the 44 advanced gastric carcinoma was showed marked enhancement in the venous phase compared with the arterial phase ( t = 4.226, P < 0.05). (3) The total accuracy of triphasic incremental helical CT in determining TNM-staging was 81.0%. Conclusion: Different types of gastric carcinoma have different enhancement features. Triphases incremental helical CT is more accurate than conventional CT in the preoperative staging of gastric carcinoma

  18. A System to Derive Optimal Tree Diameter Increment Models from the Eastwide Forest Inventory Data Base (EFIDB)

    Science.gov (United States)

    Don C. Bragg

    2002-01-01

    This article is an introduction to the computer software used by the Potential Relative Increment (PRI) approach to optimal tree diameter growth modeling. These DOS programs extract qualified tree and plot data from the Eastwide Forest Inventory Data Base (EFIDB), calculate relative tree increment, sort for the highest relative increments by diameter class, and...

  19. Ion transmission in a linear radiofrequency spectrometer

    International Nuclear Information System (INIS)

    Gomet, J.-C.

    1975-01-01

    A linear radiofrequency spectrometer is used for the purpose of experimental determination of the absolute ionization cross sections of various ions obtained by electron impact on polyatomic molecules. The transmission of the apparatus is studied: it does not only depend on the mass resolution of the spectrometer, but also on the nature of ions. It is affected by charge transfers, especially for the parent ions. An empiric way of correction of the apparatus function is given which allows the use at 10 -6 Torr [fr

  20. Annual increments, specific gravity and energy of Eucalyptus grandis by gamma-ray attenuation technique

    International Nuclear Information System (INIS)

    Rezende, M.A.; Guerrini, I.A.; Ferraz, E.S.B.

    1990-01-01

    Specific gravity annual increments in volume, mass and energy of Eucalyptus grandis at thirteen years of age were made taking into account measurements of the calorific value for wood. It was observed that the calorific value for wood decrease slightly, while the specific gravity increase significantly with age. The so-called culmination age for the Annual Volume Increment was determined to be around fourth year of growth while for the Annual Mass and Energy Increment was around the eighty year. These results show that a tree in a particular age may not have a significant growth in volume, yet one is mass and energy. (author)