WorldWideScience

Sample records for mn-dpdp enhanced t1-weighted

  1. The experimental study of the pancreatic enhancement on MR imaging with Mn-DPDP

    International Nuclear Information System (INIS)

    Gong Jingshan; Zhou Kangrong; Zeng Mengsu; Peng Weijun; Yan Fuhua; Shen Jizhang; Chen Caizhong; Shi Weibin; Zhang Shujie

    2002-01-01

    Objective: To investigate whether the exocrine glandular cells of the pancreas take in Mn-DPDP or its metabolite. Methods: A fistula tube was inserted into the major pancreatic duct through the major duodenal papillae in a group of six male dogs. The pancreatic juice was collected before and after the intravenous infusion of Mn-DPDP at a rate of 2-3 ml/min with a dose of 2 ml/kg body weight. The Mn content of pancreatic juice was measured using atomic absorption spectroscopy (AAS). T 1 -weighted spin-echo images and SPGR T 1 W images were obtained prior to and approximately 30 min after the administration of Mn-DPDP. Results: The Mn content of the pancreatic juice increased by (6.17 x 10 -3 - 1.58 x 10 -2 ) mmol/L (median 1.09 x 10 -2 mmol/L) after the administration of Mn-DPDP with statistical significance (Z = 2.20, P 1 -weighted spin echo images and SPGR images, respectively. Conclusion: The experimental study confirmed that the exocrine glandular cells of the pancreas could take in the manganese and excrete it through the pancreatic juice, which played a leading role in pancreatic enhancement on MR imaging with Mn-DPDP. The Mn-DPDP-enhanced MRI can be used for diagnosing pancreatic abnormality and has the potential ability to evaluate the exocrine function of the pancreas

  2. Mn-DPDP, the first contrast agent for the pancreas

    International Nuclear Information System (INIS)

    Gehl, H.B.; Vorwerk, D.; Klose, K.C.; Raber, H.; Guenther, R.W.

    1990-01-01

    Mn-DPDP, known as a contrast agent for the hepatobiliary system, shows signal intensity increase of the pancreas as well. This paper describes the extent of signal intensity increase in the pancreas as a function of time. Six healthy volunteers were imaged with a 1.5-T MR unit using a T1-weighted gradient-echo sequence. Acquisitions were taken in 3-minute intervals for the first 45 minutes, followed by intervals of 30 minutes for 7 hours after infusion of Mn-DPDP. As a special formulation, 10 μmol per kg Mn-DPDP were infused. The enhancement of the head and the tail of the pancreas were measured and plotted as a function of time; the percentage increase in pancreas signal intensity was calculated and compared with the increase in liver signal intensity

  3. Tumoural portal vein thrombosis. Enhancement with MnDPDP

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Lonjedo, E.; Mathieu, D.; Coffin, C.; Poyatos, C.; Anglade, M.C.

    1997-01-01

    Purpose: Intrahepatic thrombus is usually associated with either cirrhosis or hepatocellular carcinoma (HCC). Most HCCs enhance after the administration of MnDPDP (Teslascan). Our objective was to analyze the enhancement characteristics of tumour portal vein thrombi. Material and Methods: Thrombi affecting the main or segmental portal veins (17 cases) and the suprahepatic inferior vena cava (1 case) were retrospectively selected from a series of 128 patients studied with MR imaging before and after the administration of MnDPDP. Enhancement was assessed qualitatively and quantitatively. Results: All tumour thrombi enhanced after MnDPDP administration. The enhancement was more conspicuous in the GRE images. On the quantitative evaluation, the portal thrombus enhancement was greater for GRE images than SE images. Portal thrombi enhanced more than the liver and the HCCs. There was a significant difference between the enhancement of the HCCs and the thrombi with both MR imaging techniques. (orig./AJ)

  4. MnDPDP-enhanced MR imaging of the liver. Correlation with surgical findings

    International Nuclear Information System (INIS)

    Kane, P.A.; Ayton, V.; Walters, H.L.; Benjamin, I.; Heaton, N.D.; Williams, R.; Karani, J.B.

    1997-01-01

    Purpose: To compare lesion detection and characterisation predicted by MnDPDP-enhanced MR imaging with surgical excision and pathological examination. Material and Methods: Ninety patients were intravenously infused at a rate of 2 to 3 ml/min with 5 μmol/kg mangafodipir trisodium (MnDPDP, Teslascan). The patients were examined with spin-echo and gradient-echo T1-weighted MR imaging at 1 h and 24 h after the end of infusion. The results were compared with identical pre-contrast sequences. In 20 of these patients, the pre-operative MR findings were compared with intra-operative ultrasonography and histology of the resected liver specimens. Results: In those with liver metastases, there was a good correlation between MR and the hepatic disease in 11 out of 14 cases. In the group with primary liver tumours, MR findings correlated with hepatic disease in 5 out 6 cases. (orig./AJ)

  5. Lymph node enhancement at MRI with MnDPDP in primary hepatic carcinoma. Technical report

    International Nuclear Information System (INIS)

    Burkill, Guy J.C.; Mannion, Ethna M.; Healy, Jeremiah C.

    2001-01-01

    AIMS: To report two cases of lymph node enhancement in primary hepatic carcinoma following the administration of Mangafodipir trisodium (MnDPDP, Teslascan[reg ], Nycomed Amersham U.K.), an hepatocyte specific magnetic resonance imaging (MRI) contrast agent. To review our experience with this contrast agent and the literature to establish if such enhancement occurs in normal lymph nodes or has been previously described in hepatocellular carcinoma (HCC) or other lesions. MATERIALS AND METHODS: The radiological reports of all MnDPDP enhanced abdominal MRI examinations were reviewed for lymph node enlargement. The MR images from examinations with reported nodal enlargement were re-evaluated for evidence of nodal enhancement and the hospital notes and histological reports were reviewed. Nodal enhancement was considered present if lymph node signal intensity was greater than that of the spleen following MnDPDP. Literature searches were performed on Medline and PubMed for previous descriptions of lymph node enhancement following MnDPDP. RESULTS: The reports of 90 MnDPDP abdominal MRI examinations were reviewed. Of 18 cases of lymph node enlargement, two had evidence of lymph node enhancement following MnDPDP. These two cases had hepatocellular carcinoma and fibrolamellar hepatocellular carcinoma, respectively, confirmed on liver biopsy. No reports of lymph node enhancement following MnDPDP were identified in the literature. CONCLUSION: Two cases of lymph node enhancement following MnDPDP have been presented. Although histological confirmation of the lymph nodes was not obtained, the authors propose that the lymph node enhancement was due to functioning hepatocytes in lymph node metastases from the patients' histologically confirmed hepatocellular carcinomas. Burkill, G.J.C., Mannion, E.M. and Healy, J.C. (2001)

  6. NMR relaxation studies with MnDPDP

    International Nuclear Information System (INIS)

    Southon, T.E.; Grant, D.; Bjoernerud, A.; Moen, O.M.; Spilling, B.; Martinsen, I.; Refsum, H.

    1997-01-01

    Purpose: Our studies were designed to compare the efficacy of mangafodipir trisodium (MnDPDP, Teslascan) as a tissue-specific MR agent with that of manganese chloride (MnCl 2 ), to compare the efficacy of different doses and rates of administration of MnDPDP, and to collect the data needed for predicting optimum pulse sequences. Material and Methods: The dose response for the relaxation rates R1 and R2 at 0.47 T, and the manganese (Mn) concentrations in rat liver and in the liver, pancreas, heart and adrenals of pigs was determined for both MnDPDP and MnCl 2 administered i.v. Computer simulations were carried out to model the effects of different tissue Mn concentrations and TR on signal intensities and contrast-to-noise ratios. Results: In rat liver and pig organs both compounds produced a positive dose-response in R1 and tissue Mn concentration, and only small or no response in R2. The Mn concentration in rat liver was positively correlated with R1, regardless of the form in which Mn was given, or the rate of administration. Optimal imaging parametes are therefore expected to be different pre- and post-MnDPDP administration. (orig./AJ)

  7. MRI characteristics in focal hepatic disease before and after administration of MnDPDP: discriminant analysis as a diagnostic tool

    International Nuclear Information System (INIS)

    Helmberger, Thomas K.; Reiser, Maximilian F.; Jung, Gregor; Sievers, Klaus; Doehring, Wilfried; Meurer, Karoline

    2002-01-01

    The aim of this study was to determine if different types of focal hepatic lesions can be differentiated by specific quantitative and qualitative imaging characteristics pre- and post-Mangafodipir trisodium (MnDPDP) administration using a computerized multivariable, discriminant analysis (DA). In a multicenter trial, 151 patients with focal liver disease were studied at 1.5 and 1.0 T using gradient-recalled echo T1 and fast spin-echo T2-weighted images pre and post MnDPDP (0.005 mmol/kg b.w.) i.v. administration. Analysis could be performed in 141 of 151 of the patients. The variables used in both single variable analysis and DA included contrast-to-noise ratios pre and post MnDPDP, presence of rim enhancement, margin, and heterogeneity of a lesion pre and post MnDPDP. The classification of diagnoses using DA was compared with a standard of reference (HCC in 23%, metastases in 25%, cyst in 13%, FNH in 10%, hemangioma in 11%, and other or no lesion in 18% of the patients; histology in 49%, long-term follow-up in 51% of the cases). In the differentiation of the various hepatic lesions, CNR together with the presence of heterogeneity or rim enhancement as variables for DA gave the highest sensitivity, specificity, and accuracy which ranged between 65 and 93, 44 and 83, and 65 and 86%, respectively. The DA models based on post-MnDPDP variables showed better classification results than the models based on pre-MnDPDP variables. An improvement of accuracy was observed when differentiating HCC from FNH lesion groups (48.9-67.4%; p≤0.05), and when differentiating HCC from metastasis lesion groups (68.3-84.1%; p≤0.01). In all regards there was no difference for T2-weighted images pre and post MnDPDP. By combining quantitative and qualitative variables, DA proved to be a useful tool in lesion discrimination. Due to considerable heterogeneity within some of the lesion type groups, the definite diagnostic impact of MnDPDP cannot be completely established yet, and further

  8. Enhancement of the normal pancreas: comparison of manganese-DPDP and gadolinium chelate

    International Nuclear Information System (INIS)

    Kettritz, U.; Warshauer, D.M.; Brown, E.D.; Schlund, J.F.; Eisenberg, L.B.; Semelka, R.C.

    1996-01-01

    The purpose of this paper was to compare manganese-DPDP (Mn-DPDP) and gadolinium chelate (Gd-DTPA) contrast agents for enhancement of the normal pancreas. A total of 14 patients with focal liver disease underwent Mn-DPDP-and Gd-DTPA-enhanced 1.5 T MR examinations using spoiled gradient-echo (FLASH) technique at two separate times. Contrast agents were injected according to the currently recommended practices; Gd-DTPA was injected as a rapid bolus injection in a dosage of 0.1 mmol/kg, and Mn-DPDP was injected as a slow IV injection in a dosage of 5 μmol/kg. Quantitative region of interest measurements were made in 11 patients, and percent contrast enhancement of the pancreas and pancreas-fat signal-to-noise ratios (SNR) were determined for each agent. Images were also evaluated qualitativley by consensus reading of two investigators and overall scan quality was rated on a scale from 1 (poor) to 4 (very good). Enhancement of the pancreas immediately post Gd-DTPA was significantly higher than 15 min post Mn-DPDP (73.3 vs 36.3%; p=0.003). On postcontrast images the pancreas-fat SNR measruements were 7.7 (i.e., pancreas higher in signal than fat) and -6.1 for Gd-DTPA and Mn-DPDP, respectively, which was significantly different (p<0.001). Image quality was rated as 3.1 and 2.5 for Gd-DTPA- and Mn-DPDP-enhanced images, respectively. The normal pan creas enhances significantly more with Gd-DTPA than with Mn-DPDP administered under the conditions of this study. Overall image quality is also greater on the Gd-DTPA-enhanced images. (orig.)

  9. Detection of colorectal hepatic metastases using MnDPDP MR imaging and diffusion-weighted imaging (DWI) alone and in combination

    International Nuclear Information System (INIS)

    Koh, D.M.; Brown, G.; Riddell, A.M.; Scurr, E.; Allen, S.D.; Husband, J.E.; Collins, D.J.; Souza, N.M. de; Leach, M.O.; Chau, I.; Cunningham, D.

    2008-01-01

    To compare the diagnostic accuracy of MnDPDP MR imaging and diffusion-weighted imaging (DWI), alone and in combination, for detecting colorectal liver metastases in patients with suspected metastatic disease. Thirty-three consecutive patients with suspected colorectal liver metastases underwent MR imaging. Three image sets (MnDPDP, DWI and combined MnDPDP and DWI) were reviewed independently by two observers. Lesions were scored on a five-point scale for malignancy and the areas (Az) under the receiver operating characteristic curves were calculated for each observer and image set. The sensitivity and specificity for lesion detection were calculated for each image set and compared. There were 83 metastases, 49 cysts and 1 haemangioma. Using the combined set resulted in the highest diagnostic accuracy for both observers (Az = 0.94 and 0.96), with improved averaged sensitivity of lesion detection compared with the DWI set (p = 0.01), and a trend towards improved sensitivity compared with the MnDPDP set (p = 0.06). There was no difference in the averaged specificity using any of the three image sets (p > 0.5). Combination of MnDPDP MR imaging and DWI resulted in the highest diagnostic accuracy and can increase sensitivity without loss in specificity. (orig.)

  10. Clinical implications of studies with MnDPDP in animal models of hepatic abnormalities

    International Nuclear Information System (INIS)

    Ni, Y.; Marchal, G.

    1997-01-01

    Mangafodipir trisodium (manganese dipyridoxal diphosphate or MnDPDP) has been introduced as a hepatobiliary MR contrast agent (Teslascan). It is potential to assist in the characterisation of focal liver lesions, the diagnosis of local and global obstructive cholestasis and the evaluation of hepatic function in diffuse liver diseases has been explored in multiple pre-clinical experiments with appropriate animal models. The prompt negative contrast enhancement and delayed pertumoural rim-enhancement seen after i.v. injection of MnDPDP are 2 typical features of primary and secondary liver tumours with high malignancy, while the persistent positive enhancement is a sign of liver tumours of well preserved hepatocitic nature. Liver with local and total biliary obstruction can be visualized in MnDPDP-enhanced MR images as a region with prolonged signal enhancement. This agent could also be used to non-invasively evaluate diffuse liver diseases of different causes. In the present paper, we review the experimental data in the literature, provide some unpublished results and discuss the potential impact on the clinical use of MnDPDP in the liver. We conclude that MnDPDP is a promising MR liver contrast agent for the detection and characterisation of focal and diffuse liver diseases. (orig.)

  11. MnDPDP enhancement in rabbit liver after intravenous bolus injection and slow infusion

    International Nuclear Information System (INIS)

    Thorstensen, Oe.; Isberg, B.; Jorulf, H.; Westman, L.; Svahn, U.; Venizelos, N.

    1997-01-01

    Purpose: To investigate the MR-enhancing effect of mangafodipir trisodium (MnDPDP, Teslascan) in the rabbit liver in relation to dose, mode of administration and imaging window. Material and Methods: MnDPDP was administered to 18 rabbits at a dose of 10 μmol/kg or 20 μmol/kg, as a bolus injection or infusion. MR imaging of the liver was performed at different time intervals. Results: Peak liver enhancement was typically observed 10-30 min after administration and the enhancement declined with a half-time of about 5 h. This pattern was observed in all sequences (SE 400/15, FLASH, and SE 132/10), with both doses and with both rates of administration. The peak enhancement was greater, though not significantly so after 20 μmol/kg than after 10 μmol/kg. A higher relative peak signal was observed with SE 132/10 than with FLASH or SE 400/15. (orig./AJ)

  12. Mn-DPDP enhanced T1-weighted magnetic resonance cholangiography: usefulness in the diagnosis and roadmap for the treatment of intrahepatic choIedochoIithiasis

    International Nuclear Information System (INIS)

    Park, Mi Suk; Kim, Ki Whang; Yu, Jeong Sik; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Kim, Kyoung Won; Kim, Tae Kyoung; Ha, Hyun Kwon

    2004-01-01

    To assess the preliminary findings of Mn-enhanced T1-weighted MR cholangiography for the evaluation of intrahepatic choledocholithiasis. Seven patients with recurrent pyogenic cholangitis underwent conventional heavily T2-weighted and manganese-enhanced T1-weighted MR cholangiography. For the former, the two reviewers focused on intrahepatic ductal dilatation, calculi, and stricture; and for the latter, ductal enhancement. In seven patients, 13 diseased segments were depicted and intrahepatic bile ductal dilatation was present in all 13 of these in all seven patients. Calculi were present in eight segments in six patients, and stricture in four segments in three patients. Of the 13 diseased segmental ducts, six were seen at manganese-enhanced imaging to be filled with contrast material, suggesting a functioning bile duct. Combined T2-weighted and mangafodipir trisodium-enhanced T1-weighted MR cholangiography provides both anatomic detail and functional detail of the biliary system. Combined MR cholangiography is useful for the evaluation of intrahepatic choledocholithiasis, demonstrating the stricture and function of the segmental ducts involved

  13. Plasma pharmacokinetics, tissue distribution and excretion of MnDPDP in the rat and dog after intravenous administration

    International Nuclear Information System (INIS)

    Hustvedt, S.O.

    1997-01-01

    Purpose: To investigate distribution and excretion of mangafodipir (MnDPDP, Teslascan) in the rat and dog. Material and Methods: Formulations of either 14 C-MnDPDP or 54 MnDPDP were injected intravenously at near clinical doses in rats and dogs. Results: The manganese (Mn) moeity is rapidly removed from plasma with an elimination half-life of less than 25 min in both species, reflecting a rapid distribution to the tissues and an early excretion. The plasma clearance of the DPDP moeity is slower than that of Mn and it appears to distribute into the extracellular fluid. Mn is distributed largely to the liver, pancreas and kidneys, and in pregnant rats, also to foetal liver and bones. No transplacental passage of DPDP could be detected. The metal is mainly excreted by the faecal route, with a small fraction eliminated early in the urine. DPDP is rapidly and essentially completely excreted in the urine, consistent with the glomerular filtration rate. (orig./AJ)

  14. Cardiovascular effects of MnDPDP and MnCl2 in dogs with acute ischaemic heart failure

    International Nuclear Information System (INIS)

    Karlsson, J.O.G.; Pedersen, H.K.; Sager, G.; Refsum, H.; Nycomed Imaging AS, Oslo

    1997-01-01

    Purpose: To examine the cardiovascular effects of MnDPDP in a model of acute heart failure in the dog, and to compare these effects with those of MnCl 2 . Material and Methods: The study involved slow i.v. infusion of either 10, 60 and 300 μmol/kg of MnDPDP, or 1, 6 and 30 μmol/kg MnCl 2 , in increasing doses to groups of 5 dogs. Acute ischaemic heart failure was first induced by injection of polystyrene microspheres (50±10 μm) into the left coronary artery until a stable left ventricular end-diastolic pressure of approximately 20 mm Hg was achieved. The following test parameters were measured: Left ventricular end-diastolic pressure; the first derivatives of maximum rate of left ventricular contraction and relaxation; mean aortic pressure; pulmonary artery pressure; right atrial pressure; cardiac ouput; heart rate; QT-time; PQ-time; QRS-width; and plasma catecholamines. Results: Slow infusion of MnDPDP at doses up to and including 12 times the clinical dose was well tolerated in dogs without further depression of cardiovascular function during acute ischaemic heart failure. At 300 μmol/kg, i.e. 60 times the human dose, only minor haemodynamic and electrophysiological effects were seen, and these were similar to those seen after administration of 30 μmol/kg MnCl 2 . (orig./AJ)

  15. Cardiovascular effects of MnDPDP and MnCl{sub 2} in dogs with acute ischaemic heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, J.O.G. [Trondheim Univ. (Norway). Dept. of Physiology and Biomedical Engineering]|[Nycomed Imaging AS, Oslo (Norway). Research and Development; Mortensen, E. [Dept. of Physiology, Inst. of Medical Biology, Univ. of Tromsoe (Norway); Pedersen, H.K. [Dept. of Radiology, The National Hospital, Oslo (Norway); Sager, G. [Dept. of Pharmacology, Inst. of Medical Biology, Univ. of Tromsoe (Norway); Refsum, H. [Inst. for Experimental Medical Research, Ullevaal Hospital, Oslo Univ. (Norway)]|[Nycomed Imaging AS, Oslo (Norway). Research and Development

    1997-07-01

    Purpose: To examine the cardiovascular effects of MnDPDP in a model of acute heart failure in the dog, and to compare these effects with those of MnCl{sub 2}. Material and Methods: The study involved slow i.v. infusion of either 10, 60 and 300 {mu}mol/kg of MnDPDP, or 1, 6 and 30 {mu}mol/kg MnCl{sub 2}, in increasing doses to groups of 5 dogs. Acute ischaemic heart failure was first induced by injection of polystyrene microspheres (50{+-}10 {mu}m) into the left coronary artery until a stable left ventricular end-diastolic pressure of approximately 20 mm Hg was achieved. The following test parameters were measured: Left ventricular end-diastolic pressure; the first derivatives of maximum rate of left ventricular contraction and relaxation; mean aortic pressure; pulmonary artery pressure; right atrial pressure; cardiac ouput; heart rate; QT-time; PQ-time; QRS-width; and plasma catecholamines. Results: Slow infusion of MnDPDP at doses up to and including 12 times the clinical dose was well tolerated in dogs without further depression of cardiovascular function during acute ischaemic heart failure. At 300 {mu}mol/kg, i.e. 60 times the human dose, only minor haemodynamic and electrophysiological effects were seen, and these were similar to those seen after administration of 30 {mu}mol/kg MnCl{sub 2}. (orig./AJ).

  16. Benign and malignant hepatocellular tumors: evaluation of tumoral enhancement after mangafodipir trisodium injection on MR imaging

    International Nuclear Information System (INIS)

    Coffin, C.M.; Diche, T.; Mahfouz, A.E.; Alexandre, M.; Caseiro-Alves, F.; Rahmouni, A.; Vasile, N.; Mathieu, D.

    1999-01-01

    The aim of this work was to study the ability of mangafodipir trisodium (Mn-DPDP)-enhanced MR imaging in differentiating malignant from benign hepatocellular tumors. Eleven patients with pathologically proved hepatocellular carcinomas, six with focal nodular hyperplasias, and one with a single hepatocellular adenoma were examined by spin-echo and gradient-echo T1-weighted sequences before, 1 h after, and 24 h after intravenous injection of Mn-DPDP (5 μmol/kg). Quantitative analysis including enhancement and lesion-to-liver contrast-to-noise ratio, and qualitative analysis including the presence of a central area and a capsule were done on pre- and post-Mn-DPDP-enhanced images. Enhancement was observed in all the tumors with significant improvement (p < 0.05) in contrast-to-noise ratio 1 h after, and 24 h after intravenous injection of Mn-DPDP. There were no significant differences in the mean enhancement and the mean contrast-to-noise ratio (CNR) between benign and malignant tumors. No enhancement was seen within internal areas observed in 7 hepatocellular carcinomas, and in 5 focal nodular hyperplasias, and within capsules which were observed in 9 hepatocellular carcinomas. In our study, Mn-DPDP increased CNR of both benign and malignant tumors but did not enable differentiation between benign and malignant tumors of hepatocellular nature. (orig.)

  17. Detection of hepatic metastasis: Manganese- and ferucarbotran-enhanced MR imaging

    International Nuclear Information System (INIS)

    Choi, Jin-Young; Kim, Myeong-Jin; Kim, Joo Hee; Kim, Seung Hyoung; Ko, Heung-Kyu; Lim, Joon Seok; Oh, Young Taik; Chung, Jae-Joon; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2006-01-01

    Purpose: To compare the mangafodipir trisodium (MnDPDP)-enhanced and ferucarbotran-enhanced magnetic resonance imaging (MRI) for the detection of hepatic metastases. Material and methods: Twenty patients with known hepatic metastasis underwent MR imaging using mangafodipir trisodium and ferucarbotran in at least 1-day intervals. Thirty-eight metastases were confirmed either histologically or clinically. Two radiologists independently reviewed the MnDPDP-enhanced and ferucarbotran-enhanced sets in a random order. The sensitivity and accuracy of lesion detection and the ability to distinguish a benign lesion from a malignant lesion were compared by the areas (Az) under the receiver operating characteristic (ROC) curve. The lesion-liver contrast-to-noise ratios (CNR) were compared by paired t-test. Results: The overall accuracy for detecting metastases was not significantly different between the MnDPDP set (Az = 0.912 and 0.913 for reader 1 and 2, respectively) and the SPIO set (Az = 0.920 and 0.950). The CNR at the MnDPDP-enhanced images and the SPIO-enhanced images were not significantly different (P = 0.146). Conclusion: Both MnDPDP- and ferucarbotran-enhanced MRI have a comparable accuracy in detecting hepatic metastasis

  18. Mangafodipir trisodium-enhanced MRI of hepatocellular carcinoma: correlation with histological characteristics

    International Nuclear Information System (INIS)

    Kim, J.H.; Kim, M.-J.; Park, Y.N.; Lee, J.T.; Kim, B.R.; Chung, J.B.; Choi, J.S.; Kim, K.S.; Kim, K.W.

    2008-01-01

    Aim: To define histopathological factors related to the degree of mangafodipir trisodium (MnDPDP) uptake in hepatocellular carcinomas (HCCs) on magnetic resonance imaging (MRI). Materials and methods: In-phase and opposed-phase gradient-echo MRI images were obtained preoperatively in 37 patients with 38 HCCs before and 15-30 min after intravenous injection of MnDPDP. Subjective ratings of the enhancement degree, the signal-to-noise ratio (SNR) of the lesion and the liver, and the contrast enhancement ratios (CER) were compared with histopathological factors. Results: The mean SNR of HCCs increased from 59.6 to 95.0 (CER = 59.5%), whereas that of the liver increased from 75.1 to 108.7 (CER = 45.2%). Eight HCCs showed mild enhancement, 11 moderate enhancement, and 15 strong enhancement. There was no visually perceptible enhancement in four HCCs (10.3%). The degree of MnDPDP enhancement was significantly related with the cell density ratio (p < .05) and monoclonal hepatocyte antibody positivity (p < 0.005), but not with size, growth type, cell type, histological type, cytokeratin 7, or cytokeratin 19. Well-differentiated HCC showed higher MnDPDP enhancement compared with higher grade HCCs, but the differences were not statistically significant. Conclusion: The uptake of MnDPDP by HCC was correlated with hepatocyte antibody expression and the cellular density ratio. Well-differentiated HCC tended to show higher MnDPDP enhancement

  19. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  20. Preclinical evaluation of severely defective manganese-based nanocrystal as a liver-specific contrast media for MR imaging: comparison with Gd-EOB-DTPA and MnDPDP

    Science.gov (United States)

    Zhang, Yu; Xiao, Xiao-ping; Shu, Ting; Cai, Jing; Xiao, Xin-lan; Li, Yan-shu; Zhang, Zhong-wei; Tang, Qun

    2018-06-01

    Manganese-based (chemically formulated of KMnF3) nanocrystal was evaluated as a liver-specific contrast agent for MR imaging and its imaging performance was also compared with those of two commercial hepatobiliary contrast media (Gd-EOB-DTPA and MnDPDP). KMnF3 nanocrystal was post-treated using a plasma technique to cause severe defects, leading to appropriate water dispersibility and high relaxivity. Severely defective KMnF3 nanocrystal (SD-KMnF3) has characteristic high tolerance, as evidenced by cytotoxicity on the macrophage cell, and acute and subchronic toxicity on the healthy mouse. SD-KMnF3 showed better hepatic MR imaging as the T 1 relaxation time of the liver decreased to only 17% of the control group, compared to 22% of the control group for Gd-EOB-DTPA (P hepatocarcinoma or metastatic lesions.

  1. Fat-suppressed MRI of musculoskeletal infection: fast T2-weighted techniques versus gadolinium-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Miller, T.T.; Randolph, D.A. Jr.; Staron, R.B.; Feldman, F.; Cushin, S.

    1997-01-01

    Purpose. To investigate gadolinium's role in imaging musculoskeletal infection by comparing the conspicuity and extent of inflammatory changes demonstrated on gadolinium-enhanced fat-suppressed T1-weighted images versus fat-suppressed fast T2-weighted sequences. Design. Eighteen patients with infection were imaged in a 1.5-T unit, using frequency-selective and/or inversion recovery fat-suppressed fast T2-weighted images (T2WI) and gadolinium-enhanced frequency-selective fat-suppressed T1-weighted images (T1WI). Thirty-four imaging planes with both a fat-suppressed gadolinium-enhanced T1-weighted sequence and a fat-suppressed T2-weighted sequence were obtained. Comparison of the extent and conspicuity of signal intensity changes was made for both bone and soft tissue in each plane. Results. In bone, inflammatory change was equal in extent and conspicuity on fat-suppressed T2WI and fat-suppressed T1WI with gadolinium in 19 planes, more extensive or conspicuous on T2WI in three planes, and less so on T2WI in two planes. Marrow was normal on all three sequences in 10 cases. In soft tissue, inflammatory change was seen equally well in 20 instances, more extensively or conspicuously on the T2WI in 11 instances, and less so on T2WI in 2 instances. One case had no soft tissue involvement on any of the sequences. Five abscesses and three joint effusions were present, all more conspicuously delineated from surrounding inflammatory change on the fat-saturated T1WI with gadolinium. The average imaging time for the fat-saturated T1WI with gadolinium was 6.75 min, while that of the T2-weighted sequences was 5.75 min. Conclusion. Routine use of gadolinium is not warranted. Instead, gadolinium should be reserved for clinically suspected infection in or around a joint, and in cases refractory to medical or surgical treatment due to possible abscess formation. (orig.)

  2. Lumbosacral lipoma : gadolinium-enhanced fat saturation T1 weighted MR image is necessary?

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyun Chul; Chung, Tae Woong; Seo, Jeong Jin; Chung, Gwang Woo; Kim, Yun Hyeon; Kim, Jae Kyu; Park, Jin Gyoon; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of contrast-enhanced fat saturation T1-weighted imaging for the evaluation of spinal lipoma, compared with clinical symptoms and surgical findings. Ten patients with lipomyelomeningocele, confirmed by surgery, were included in this study. In all cases, conventional spin echo T1-and T2-weighted MR imaging, and contrast-enhanced fat saturation T1-weighted imaging was performed to evaluate clinical symptoms, the position of the conus medullaris, the presence of cord tethering, and associated anomalies, and to compare the relative usefulness of the techniques. All ten patients were suffering from lipomyelomeningocele without filum terminale fibrolipoma or intradural lipoma. All cases were associated with cord tethering. As associated anomalies, there were seven cases of syringomyelia without hydrocephalus or anorectal anomaly. To evaluate the position of the spinal conus and the presence of cord tethering, conventional T1-weighted imaging was more useful than the contrast-enhanced fat saturation equivalent. In patients with early-stage spinal lipoma, MRI is useful for evaluation of the causes and position of cord tethering and associated anomalies Our results suggest that contrast-enhanced fat saturation T1-weighted images do not provide additional information concerning spinal lipoma, and that for the diagnosis of this condition, conventional T1 and T2-weighted images are more useful than those obtained by contrast-enhanced fat saturation T1-weighted imaging

  3. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  4. Gadoxate-enhanced T1-weighted MR cholangiography: comparison of 1.5 T and 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Koelblinger, C.; Schima, W.; Weber, M.; Mang, T.; Nemec, S.; Kulinna-Cosentini, C.; Bastati, N.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Univ. Wien (Austria)

    2009-06-15

    Purpose: to qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5 T and 3.0 T. Materials and methods: a total of 40 patients with a non-dilated biliary system were retrospectively included in the study. T1-weighted MR cholangiography 20 min after IV administration of 0.025 mmol/kg gadoxate (Primovist trademark) was performed in 20 patients at 1.5 T and in another 20 patients at 3.0 T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct - LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: the CNRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0 T. Qualitative analysis showed a significant superiority for 3.0 T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). (orig.)

  5. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    International Nuclear Information System (INIS)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B; Wang, K; Bayram, E

    2016-01-01

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  6. SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J; Son, J; Arun, B; Hazle, J; Hwang, K; Madewell, J; Yang, W; Dogan, B [UT MD Anderson Cancer Center, Houston, TX (United States); Wang, K; Bayram, E [GE Healthcare Technologies, Waukesha, Wisconsin (United States)

    2016-06-15

    Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the

  7. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  8. T1ρ-weighted Dynamic Glucose-enhanced MR Imaging in the Human Brain.

    Science.gov (United States)

    Paech, Daniel; Schuenke, Patrick; Koehler, Christina; Windschuh, Johannes; Mundiyanapurath, Sibu; Bickelhaupt, Sebastian; Bonekamp, David; Bäumer, Philipp; Bachert, Peter; Ladd, Mark E; Bendszus, Martin; Wick, Wolfgang; Unterberg, Andreas; Schlemmer, Heinz-Peter; Zaiss, Moritz; Radbruch, Alexander

    2017-12-01

    Purpose To evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T. Materials and Methods This prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange-sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The median signal intensities of the assessed brain regions were compared by using the Wilcoxon rank-sum test. Results In healthy volunteers, the median signal intensity in basal ganglia gray matter (DGEρ = 4.59%) was significantly increased compared with that in white matter tissue (DGEρ = 0.65%) (P = .028). In patients, the median signal intensity in the glucose-enhanced tumor region as displayed on T1ρ-weighted DGE images (DGEρ = 2.02%) was significantly higher than that in contralateral normal-appearing white matter (DGEρ = 0.08%) (P brain glucose physiology and pathophysiologically increased glucose uptake and may have the potential to provide information about glucose metabolism in tumor tissue. © RSNA, 2017 Online supplemental material is available for this article.

  9. Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T-1-weighted MRI at 3T

    DEFF Research Database (Denmark)

    Larsson, H.B.W.; Hansen, A.E.; Berg, H.K.

    2008-01-01

    Purpose: To develop a method for the measurement of brain perfusion based on dynamic contrast-enhanced T-1-weighted MR imaging. Materials and Methods: Dynamic imaging of the first pass of a bolus of a paramagnetic contrast agent was performed using a 3T whole-body magnet and a T-1-weighted fast...... field echo sequence. The input function was obtained from the internal carotid artery. An initial T-1 measurement was performed in order to convert the MR signal to concentration of the contrast agent. Pixelwise and region of interest (ROI)based calculation of cerebral perfusion (CBF) was performed...... inside the infarct core was, 9 mL/100g/min in one of the stroke patients. The other stroke patient had postischemic hyperperfusion and CBF was 140 mL/100g/min. Conclusion: Absolute values of brain perfusion can be obtained using dynamic contrast-enhanced MRI. These values correspond,to expected values...

  10. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    International Nuclear Information System (INIS)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo

    1994-01-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author)

  11. Evaluation of bone marrow by opposed phase T1-weighted images and enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Miyashita, Tsuguhiro; Hayashi, Hiromitsu; Horiuchi, Junichi; Nomura, Takeo; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-09-01

    We investigated bone marrow in a control group, cases of aplastic anemia and post-irradiation patients by examining T1-weighted (T1W1), short T1 inversion recovery (STIR), opposed phase T1W1 (op-T1W1) and Gd-DTPA enhanced op-T1W1 images obtained by 0.5 T MRI. Bone marrow was classified into four types based on MR findings. Normal marrow showed low intensity on op-T1W1 and STIR images without enhancement (I). Fatty marrow, which showed high intensity on T1W1 and op-T1W1 images was observed in aplastic anemia and post-irradiation patients (II). Hematopoietic marrow (III) showed low intensity on op-T1W1 and enhanced, while active hematopoietic marrow (IV) revealed high intensity on both STIR and op-T1W1 images and was enhanced following Gd-DTPA infusion. Aplastic anemia of moderate grade included types II, III and IV. Enhanced MR was needed to differentiate between types I and III since both types showed low intensity on op-T1W1 images. Furthermore, type IV was considered as hyperplastic compared with type III. Enhanced MR and op-T1W1 images were useful in evaluating hematopoiesis of bone marrow. (author).

  12. Optimal MR pulse sequences for hepatic hemangiomas : comparison of T2-weighted turbo-spin-echo, T2-weighted breath-hold turbo-spin-echo, and T1-weighted FLASH dynamic imaging

    International Nuclear Information System (INIS)

    Wang, Wen Chao; Choi, Byung Ihn; Han, Joon Koo; Kim, Tae Kyoung; Cho, Soon Gu

    1997-01-01

    To optimize MR imaging pulse sequences in the imaging of hepatic hemangioma and to evaluate on dynamic MR imaging the enhancing characteristics of the lesions. Twenty patients with 35 hemangiomas were studied by using Turbo-spin-echo (TSE) sequence (T2-weighted, T2- and heavily T2-weighted breath-hold) and T1-weighted FLASH imaging acquired before, immediately on, and 1, 3 and 5 minutes after injection of a bolus of Gd-DTPA (0.1mmol/kg). Phased-array multicoil was employed. Images were quantitatively analyzed for lesion-to-liver signal difference to noise ratios (SD/Ns), and lesion-to-liver signal ratios (H/Ls), and qualitatively analyzed for lesion conspicuity. The enhancing characteristics of the hemangiomas were described by measuring the change of signal intensity as a curve in T1-weighted FLASH dynamic imaging. For T2-weighted images, breath-hold T2-weighted TSE had a slightly higher SD/N than other pulse sequences, but there was no statistical difference in three fast pulse sequences (p=0.211). For lesion conspicuity, heavily T2-weighted breath-hold TSE images was superior to T2-weighted breath-hold or non-breath-hold TSE (H/L, 5.75, 3.81, 2.87, respectively, p<0.05). T2-weighted breath-hold TSE imaging was more effective than T2-weighted TSE imaging in removing lesion blurring or lack of sharpness, and there was a 12-fold decrease in acquisition time (20sec versus 245 sec). T1-weighted FLASH dynamic images of normal liver showed peak enhancement at less than 1 minute, and of hemangioma at more than 3 minutes;the degree of enhancement for hemangioma decreased after a 3 minute delay. T2-weighed breath-hold TSE imaging and Gd-DTPA enhanced FLASH dynamic imaging with 5 minutes delay are sufficient for imaging hepatic hemangiomas

  13. Contrast-enhanced Magnetic Resonance Imaging of Pelvic Bone Metastases at 3.0 T: Comparison Between 3-dimensional T1-weighted CAIPIRINHA-VIBE Sequence and 2-dimensional T1-weighted Turbo Spin-Echo Sequence.

    Science.gov (United States)

    Yoon, Min A; Hong, Suk-Joo; Lee, Kyu-Chong; Lee, Chang Hee

    2018-06-12

    This study aimed to compare 3-dimensional T1-weighted gradient-echo sequence (CAIPIRINHA-volumetric interpolated breath-hold examination [VIBE]) with 2-dimensional T1-weighted turbo spin-echo sequence for contrast-enhanced magnetic resonance imaging (MRI) of pelvic bone metastases at 3.0 T. Thirty-one contrast-enhanced MRIs of pelvic bone metastases were included. Two contrast-enhanced sequences were evaluated for the following parameters: overall image quality, sharpness of pelvic bone, iliac vessel clarity, artifact severity, and conspicuity and edge sharpness of the smallest metastases. Quantitative analysis was performed by calculating signal-to-noise ratio and contrast-to-noise ratio of the smallest metastases. Significant differences between the 2 sequences were assessed. CAIPIRINHA-VIBE had higher scores for overall image quality, pelvic bone sharpness, iliac vessel clarity, and edge sharpness of the metastatic lesions, and had less artifacts (all P 0.05). Our results suggest that CAIPIRINHA-VIBE may be superior to turbo spin-echo for contrast-enhanced MRI of pelvic bone metastases at 3.0 T.

  14. Development of Bifunctional Gadolinium-Labeled Superparamagnetic Nanoparticles (Gd-MnMEIO for In Vivo MR Imaging of the Liver in an Animal Model.

    Directory of Open Access Journals (Sweden)

    Yu-Ting Kuo

    Full Text Available Liver tumors are common and imaging methods, particularly magnetic resonance imaging (MRI, play an important role in their non-invasive diagnosis. Previous studies have shown that detection of liver tumors can be improved by injection of two different MR contrast agents. Here, we developed a new contrast agent, Gd-manganese-doped magnetism-engineered iron oxide (Gd-MnMEIO, with enhancement effects on both T1- and T2-weighted MR images of the liver. A 3.0T clinical MR scanner equipped with transmit/receiver coil for mouse was used to obtain both T1-weighted spoiled gradient-echo and T2-weighted fast spin-echo axial images of the liver before and after intravenous contrast agent injection into Balb/c mice with and without tumors. After pre-contrast scanning, six mice per group were intravenously injected with 0.1 mmol/kg Gd-MnMEIO, or the control agents, i.e., Gd-DTPA or SPIO. The scanning time points for T1-weighted images were 0.5, 5, 10, 15, 20, 25, and 30 min after contrast administration. The post-enhanced T2-weighted images were then acquired immediately after T1-weighted acquisition. We found that T1-weighted images were positively enhanced by both Gd-DTPA and Gd-MnMEIO and negatively enhanced by SPIO. The enhancement by both Gd-DTPA and Gd-MnMEIO peaked at 0.5 min and gradually declined thereafter. Gd-MnMEIO (like Gd-DTPA enhanced T1-weighted images and (like SPIO T2-weighted images. Marked vascular enhancement was clearly visible on dynamic T1-weighted images with Gd-MnMEIO. In addition, the T2 signal was significantly decreased at 30 min after administration of Gd-MnMEIO. Whereas the effects of Gd-MnMEIO and SPIO on T2-weighted images were similar (p = 0.5824, those of Gd-MnMEIO and Gd-DTPA differed, with Gd-MnMEIO having a significant T2 contrast effect (p = 0.0086. Our study confirms the feasibility of synthesizing an MR contrast agent with both T1 and T2 shortening effects and using such an agent in vivo. This agent enables tumor

  15. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Koichi, E-mail: k-takano@fukuoka-u.ac.jp; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-15

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  16. Intracranial arterial wall enhancement using gadolinium-enhanced 3D black-blood T1-weighted imaging

    International Nuclear Information System (INIS)

    Takano, Koichi; Hida, Kosuke; Kuwabara, Yasuo; Yoshimitsu, Kengo

    2017-01-01

    Purpose: We investigated the enhancement of the intracranial arterial walls with gadolinium-enhanced, black-blood three-dimensional T1-weighted imaging (Gd-3DBB) by using an improved motion-sensitized driven-equilibrium (iMSDE)—prepared volumetric isotropic turbo spin-echo acquisition (VISTA). Methods: A total of 115 patients underwent FLAIR, 3D-TOF-MRA and Gd-3DBB with a 1.5-T scanner. The degree and distribution of the arterial wall enhancement on Gd-3DBB was assessed. The association of the degree of wall enhancement with brain infarction/ischemic lesions on FLAIR, luminal changes on 3D-TOF-MRA, and cardiovascular risk factors (CVRFs) was investigated by univariate and multiple logistic regression analyses. Results: Strong enhancement of the arterial walls was observed in 77 vertebral arteries (33.5%), 4 basilar arteries (3.5%), 31 supraclinoid internal carotid arteries (ICAs) (13.5%) and 8 middle cerebral arteries (3.5%). In addition, 221 intrapetrous ICAs (96.1%) showed strong enhancement. After adjusting for confounding factors, multivariate analyses showed that the patient age was independently associated with the strong wall enhancement of the arteries for both the posterior (OR, 1.088; 95% CI, 1.034–1.146) and the anterior circulation (OR, 1.098, 95% CI 1.029–1.172). In addition, the presence of the supratentorial brain infarctions was independently associated with the strong wall enhancement in the anterior circulation excluding the intrapetrous ICAs (OR, 4.097; 95% CI, 1.483–11.319). Conclusions: Although the arterial wall enhancement on the Gd-3DBB probably reflects normal aging, the enhancement in the anterior circulation might be related to brain infarctions. On the other hand, the intrapetrous ICA enhancement is considered a nonspecific finding and should not be mistaken for arterial pathologies such as atherosclerosis or arteritis.

  17. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT

    NARCIS (Netherlands)

    M. Oudkerk (Matthijs); C.G. Torres; B. Song; M. Konig; J. Grimm; J. Fernandez-Cuadrado; B. op de Beeck; M. Marquardt; P. van Dijk (Pieter); J.C. de Groot (Jan Cees)

    2002-01-01

    textabstractPURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were

  18. Role of MR imaging in the differentiation of benign and nonbenign intracranial meningiomas. The utility of contrast-enhanced T1-weighted images

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Matsuo, Michimasa

    1996-01-01

    The purpose of this study was to develop useful criteria for distinguishing nonbenign (atypical and malignant) primary intracranial meningiomas from their benign counterparts by using magnetic resonance imaging (MRI). To determine useful MRI findings for this purpose, 12 benign and five nonbenign meningiomas were retrospectively evaluated according to the following items: tumor signal intensity on plain T1-, T2- and proton density-weighted images, degree of perifocal edema on T2-weighted images, morphology of the tumor margin on contrast-enhanced T1-weighted images, presence of irregular nodule and/or mushrooming pattern on contrast-enhanced T1-weighted images, homogeneity of the tumor on contrast-enhanced T1-weighted images, and presence of marked skull destruction. Markedly irregular tumor margin, presence of irregular nodule and/or mushrooming pattern and markedly inhomogeneous enhancing pattern were significantly more frequent in nonbenign meningiomas. We defined these three MRI findings as nonbenign findings, and tried to categorize meningiomas by the number of nonbenign findings. It was found that 10 meningiomas with no or one nonbenign finding were benign lesions, of four meningiomas with two nonbenign findings two were benign lesions and two were nonbenign lesions, and three meningiomas with three nonbenign findings were nonbenign lesions. The two benign meningiomas with two nonbenign findings were accompanied by increased mitotic activity or brain invasion. Contrast-enhanced T1-weighted images were considered very useful in distinguishing benign and nonbenign meningiomas. (author)

  19. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  20. MR imaging signal enhancement of normal intracranial and extracranial structures

    International Nuclear Information System (INIS)

    Muraki, A.S.; Carvlin, M.J.; Francisco, J.; Rocklage, S.M.; Quay, S.

    1988-01-01

    The authors report their initial experience using a paramagnetic manganese chelate complex as a contrast agent for magnetic resonance (MR) imaging of the central nervous system. Five female cats weighing 2-4 kg were used, and anesthesia was induced and maintained with intravenous nembutal (15-25 mg/kg). This contrast agent, manganese (II) N, N'-bis(pyridoxal-5-phosphate) ethylenediamine-N,N'-diacetic acid, or Mn(DPDP)(Salutar), has previously shown efficacy for MR imaging of the hepatobiliary axis but has not been employed in neuroradiologic imaging. T1-weighted (repetition time, 400 msec, echo time, 15, 26 msec; 4-mm sections) spin-echo images were acquired before and after intravenous administration (100 μmol/kg) of the contrast agent. On post-contrast images, the pituitary gland, infundibulum and portohypophyseal system of the hypothalamus and choroid lexus demonstrated signal increase at t=0-30 minutes after injection

  1. Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J [Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA (Netherlands)], E-mail: p.vos@rad.umcn.nl

    2010-03-21

    In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.

  2. Low-Molecular-Weight Iron Chelates May Be an Alternative to Gadolinium-based Contrast Agents for T1-weighted Contrast-enhanced MR Imaging.

    Science.gov (United States)

    Boehm-Sturm, Philipp; Haeckel, Akvile; Hauptmann, Ralf; Mueller, Susanne; Kuhl, Christiane K; Schellenberger, Eyk A

    2018-02-01

    Purpose To synthesize two low-molecular-weight iron chelates and compare their T1 contrast effects with those of a commercial gadolinium-based contrast agent for their applicability in dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging. Materials and Methods The animal experiments were approved by the local ethics committee. Two previously described iron (Fe) chelates of pentetic acid (Fe-DTPA) and of trans-cyclohexane diamine tetraacetic acid (Fe-tCDTA) were synthesized with stability constants several orders of magnitude higher than those of gadolinium-based contrast agents. The T1 contrast effects of the two chelates were compared with those of gadopentetate dimeglumine in blood serum phantoms at 1.5 T, 3 T, and 7 T. For in vivo studies, a human breast cancer cell line (MDA-231) was implanted in five mice per group. The dynamic contrast effects of the chelates were compared by performing DCE MR imaging with intravenous application of Fe-DTPA or Fe-tCDTA on day 1 and DCE MR imaging in the same tumors with gadopentetate dimeglumine on day 2. Quantitative DCE maps were generated with software and were compared by means of a one-tailed Pearson correlation test. Results Relaxivities in serum (0.94 T at room temperature) of Fe-tCDTA (r1 = 2.2 mmol -1 · sec -1 , r2 = 2.5 mmol -1 · sec -1 ) and Fe-DTPA (r1 = 0.9 mmol -1 · sec -1 , r2 = 0.9 mmol -1 · sec -1 ) were approximately twofold and fivefold lower, respectively, compared with those of gadopentetate dimeglumine (r1 = 4.1 mmol -1 · sec -1 , r2 = 4.8 mmol -1 · sec -1 ). Used at moderately higher concentrations, however, iron chelates generated similar contrast effects at T1-weighted MR imaging in vitro in serum, in vivo in blood, and for DCE MR imaging of breast cancer xenografts. The volume transfer constant values for Fe-DTPA and Fe-tCDTA in the same tumors correlated well with those observed for gadopentetate dimeglumine (Fe-tCDTA Pearson R, 0.99; P = .0003; Fe-DTPA Pearson R, 0.97; P

  3. Physiochemical characterisation of mangafodipir trisodium

    International Nuclear Information System (INIS)

    Tirkkonen, B.; Grace, D.; Haile, Y.; Holm, K.M.; Hope, H.; Larsen, Aa.; Lunde, H.S.; Sjoegren, C.E.

    1997-01-01

    Purpose: To determine the structure and various physicochemical properties of mangafodipir (MnDPDP) trisodium, the active ingredient of Teslascan, a new organ-specific contrast medium for MR imaging. Material and Methods: The structure of MnDPDP trisodium crystals was determined by X-ray crystallography. The possible existence of polymorphism in MnDPDI trisodium was evaluated by powder X-ray diffraction, optical microscopy, thermal analysis and IR spectroscopy. In addition, various spectroscopic techniques and phyicochemical measurements were used for characterisation of MnDPDP trisodium. Results: The crystallogrpahic data obtained for MnDPDP trisodium show that the general core structure of the MnDPDP anion is similar to that seen in related substances. The metal coordination geometry is a distorted octahedron defined by 2 phenolate oxygens, 2 carboxylate oxygens and 2 amine nitrogens. The unit cell contains 2 MnDPDP anions, 6 sodium ions and 50 water molecules. The various spectroscopic data are consistent with the structure determined by X-ray crystallography. The product (Teslascan) has low viscosity, is isotonic with blood and has a physiological pH. (orig./AJ)

  4. STrategically Acquired Gradient Echo (STAGE) imaging, part I: Creating enhanced T1 contrast and standardized susceptibility weighted imaging and quantitative susceptibility mapping.

    Science.gov (United States)

    Chen, Yongsheng; Liu, Saifeng; Wang, Yu; Kang, Yan; Haacke, E Mark

    2018-02-01

    To provide whole brain grey matter (GM) to white matter (WM) contrast enhanced T1W (T1WE) images, multi-echo quantitative susceptibility mapping (QSM), proton density (PD) weighted images, T1 maps, PD maps, susceptibility weighted imaging (SWI), and R2* maps with minimal misregistration in scanning times creating enhanced GM/WM contrast (the T1WE). The proposed T1WE image was created from a combination of the proton density weighted (6°, PDW) and T1W (24°) images and corrected for RF transmit field variations. Prior to the QSM calculation, a multi-echo phase unwrapping strategy was implemented using the unwrapped short echo to unwrap the longer echo to speed up computation. R2* maps were used to mask deep grey matter and veins during the iterative QSM calculation. A weighted-average sum of susceptibility maps was generated to increase the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The proposed T1WE image has a significantly improved CNR both for WM to deep GM and WM to cortical GM compared to the acquired T1W image (the first echo of 24° scan) and the T1MPRAGE image. The weighted-average susceptibility maps have 80±26%, 55±22%, 108±33% SNR increases across the ten subjects compared to the single echo result of 17.5ms for the putamen, caudate nucleus, and globus pallidus, respectively. STAGE imaging offers the potential to create a standardized brain imaging protocol providing four pieces of quantitative tissue property information and multiple types of qualitative information in just 5min. Published by Elsevier Inc.

  5. Improved supercapacitor performance of MnO2-electrospun carbon nanofibers electrodes by mT magnetic field

    Science.gov (United States)

    Zeng, Zheng; Liu, Yiyang; Zhang, Wendi; Chevva, Harish; Wei, Jianjun

    2017-08-01

    This work reports on a finding of mT magnetic field induced energy storage enhancement of MnO2-based supercapacitance electrodes (magneto-supercapacitor). Electrodes with MnO2 electrochemically deposited at electrospun carbon nanofibers (ECNFs) film are studied by cyclic voltammetry (CV), galvanostatic charge/discharge, electrochemical impedance spectroscopy (EIS), and life cycle stability tests in the presence/absence of milli-Tesla (mT) magnetic fields derived by Helmholtz coils. In the presence of a 1.34 mT magnetic field, MnO2/ECNFs shows a magneto-enhanced capacitance of 141.7 F g-1 vs. 119.2 F g-1 (∼19% increase) with absence of magnetic field at a voltage sweeping rate of 5 mV s-1. The mechanism of the magneto-supercapacitance is discussed and found that the magnetic susceptibility of the MnO2 significantly improves the electron transfer of a pseudo-redox reaction of Mn(IV)/Mn(III) at the electrode, along with the magnetic field induced impedance effect, which may greatly enhance the interface charge density, facilitate electrolyte transportation, and improve the efficiency of cation intercalation/de-intercalation of the pseudocapacitor under mT-magnetic field exposure, resulting in enhancement of energy storage capacitance and longer charge/discharge time of the MnO2/ECNFs electrode without sacrificing its life cycle stability.

  6. Postcontrast T1-weighted brain magnetic resonance imaging in pediatric patients: comparison between postcontrast fat-suppression imaging and conventional T1-weighted or magnetization transfer imaging

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Goo, Hyun Woo

    2004-01-01

    We wished to assess the merits and weaknesses of postcontrast fat-suppression (FS) brain MR imaging in children for the evaluation of various enhancing lesions as compared with postcontrast conventional T1-weighted or magnetization transfer (MT) imaging. We reviewed the records of those patients with enhancing lesions on brain MR imaging who had undergone both FS imaging and one of the conventional T1-weighted or MT imaging as a post-contrast T1-weighted brain MR imaging. Thirty-one patients (21 male, 10 female; mean age, 8.7 years) with 38 enhancing lesions (18 intra-axial, 16 extra-axial and 4 orbital locations) were included in this study. There were 27 pairs of FS and conventional imagings, and 13 pairs of FS and MT imagings available for evaluation. Two radiologists visually assessed by consensus the lesions' conspicuity, and they also looked for the presence of flow or susceptibility artifacts in a total of 40 pairs of MR imagings. For 19 measurable lesions (14 pairs of FS and conventional T1-weighted imagings, 5 pairs of FS and MT imagings), the contrast ratios between the lesion and the normal brain ([SIlesion-SIwater]/[SInormal brain-SIwater]) were calculated and compared. Compared with conventional imaging, the lesion conspicuity on FS imaging was better in 10 cases (7 extra-axial lesions, 2 orbital lesions and 1 fat-containing intra-axial lesion), equal in 16 cases, and worse in one case. Compared with MT imaging, the lesion conspicuity on FS imaging was better in 3 cases (2 extra-axial lesions and 1 intra-axial lesion), equal in 8 cases, and worse in 2 cases. Image quality of FS imaging was compromised by flow or susceptibility artifacts for 7 patients. The contrast ratios for FS imaging were not significantly different from those for conventional imaging (2.2±0.7 vs. 2.2±0.6, respectively, p=0.914) and they were significantly lower than those for MT imaging (2.4±0.8 vs. 4.5±1.5, respectively, p=0.018). Postcontrast FS brain MR imaging appears to be

  7. Comparison of different magnetic resonance cholangiography techniques in living liver donors including Gd-EOB-DTPA enhanced T1-weighted sequences.

    Directory of Open Access Journals (Sweden)

    Sonja Kinner

    Full Text Available Preoperative evaluation of potential living liver donors (PLLDs includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w and Gd-EOB-DTPA enhanced T1-weighted (T1w magnetic resonance cholangiography (MRC techniques in the evaluation of PLLDs.30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany using (A 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo fat saturated (fs in axial plane, (B 2D T2w HASTE fs thick slices in coronal plane, (C free breathing 3D T2w TSE (turbo spin echo RESTORE (high-resolution navigator corrected plus (D maximum intensity projections (MIPs, (E T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions plus (F MIPs and (G T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G and with (H inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated.Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622-0.804.3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.

  8. The interplay of T1- and T2-relaxation on T1-weighted MRI of hMSCs induced by Gd-DOTA-peptides.

    Science.gov (United States)

    Cao, Limin; Li, Binbin; Yi, Peiwei; Zhang, Hailu; Dai, Jianwu; Tan, Bo; Deng, Zongwu

    2014-04-01

    Three Gd-DOTA-peptide complexes with different peptide sequence are synthesized and used as T1 contrast agent to label human mesenchymal stem cells (hMSCs) for magnetic resonance imaging study. The peptides include a universal cell penetrating peptide TAT, a linear MSC-specific peptide EM7, and a cyclic MSC-specific peptide CC9. A significant difference in labeling efficacy is observed between the Gd-DOTA-peptides as well as a control Dotarem. All Gd-DOTA-peptides as well as Dotarem induce significant increase in T1 relaxation rate which is in favor of T1-weighted MR imaging. Gd-DOTA-CC9 yields the maximum labeling efficacy but poor T1 contrast enhancement. Gd-DOTA-EM7 yields the minimum labeling efficacy but better T1 contrast enhancement. Gd-DOTA-TAT yields a similar labeling efficacy as Gd-DOTA-CC9 and similar T1 contrast enhancement as Gd-DOTA-EM7. The underlying mechanism that governs T1 contrast enhancement effect is discussed. Our results suggest that T1 contrast enhancement induced by Gd-DOTA-peptides depends not only on the introduced cellular Gd content, but more importantly on the effect that Gd-DOTA-peptides exert on the T1-relaxation and T2-relaxation processes/rates. Both T1 and particularly T2 relaxation rate have to be taken into account to interpret T1 contrast enhancement. In addition, the interpretation has to be based on cellular instead of aqueous longitudinal and transverse relaxivities of Gd-DOTA-peptides. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Brain capillary transit time heterogeneity in healthy volunteers measured by dynamic contrast-enhanced T1-weighted perfusion MRI

    DEFF Research Database (Denmark)

    Larsson, Henrik B.W.; Vestergaard, Mark B.; Lindberg, Ulrich

    2017-01-01

    Purpose: Capillary transit time heterogeneity, measured as CTH, may set the upper limit for extraction of substances in brain tissue, e.g., oxygen. The purpose of this study was to investigate the feasibility of dynamic contrast-enhanced T1 weighted MRI (DCE-MRI) at 3 Tesla (T), in estimating CTH...

  10. The Effect of the Degree of Luminal Contrast-Enhancement on CT Measurement of Plaque Size: A Comparison with T1-weighted Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Hur, Jin; Lee, Hye Jeong; Kim, Young Jin; Choe, Kyu Ok; Kim, Tae Hoon

    2010-01-01

    We studied early and delayed contrast-enhanced CT to determine the effects of the degree of luminal enhancement on the measurement of plaque size compared to T1-weighted MRI. T1-weighted MRI and a two-phase contrast-enhanced CT was performed in 5 New Zealand white rabbits with atherosclerosis. Early-phase images were acquired during an expected peak enhancement period of the lumen; delayed-phase images were acquired 240 sec after administration of the contrast media. Anteroposterior and lateral luminal diameters (APD, LD), luminal area (LA), total vessel area (TVA), and plaque area (PA) of the aorta were measured on MRI and CT, respectively and compared to each other. A total of 78 slices of the aorta were analyzed. PA, measured on T1-weighted MR images, was significantly greater than PA for both early-phase and delayed-phase CT (p 2 (p 2 (p 2 (p = 0.159) for MRI vs. early-phase CT, MRI vs. delayed-phase CT, and early-phase CT vs. delayed-phase CT, respectively. Different luminal densities by contrast enhancement do not affect the CT measurement of plaque area for the detection of obstructive coronary artery disease

  11. Free-breathing contrast-enhanced T1-weighted gradient-echo imaging with radial k-space sampling for paediatric abdominopelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chandarana, Hersh; Block, Kai T.; Winfeld, Matthew J.; Lala, Shailee V.; Mazori, Daniel; Giuffrida, Emalyn; Babb, James S.; Milla, Sarah S. [New York University Langone Medical Center, Department of Radiology, New York, NY (United States)

    2014-02-15

    To compare the image quality of contrast-enhanced abdominopelvic 3D fat-suppressed T1-weighted gradient-echo imaging with radial and conventional Cartesian k-space acquisition schemes in paediatric patients. Seventy-three consecutive paediatric patients were imaged at 1.5 T with sequential contrast-enhanced T1-weighted Cartesian (VIBE) and radial gradient echo (GRE) acquisition schemes with matching parameters when possible. Cartesian VIBE was acquired as a breath-hold or as free breathing in patients who could not suspend respiration, followed by free-breathing radial GRE in all patients. Two paediatric radiologists blinded to the acquisition schemes evaluated multiple parameters of image quality on a five-point scale, with higher score indicating a more optimal examination. Lesion presence or absence, conspicuity and edge sharpness were also evaluated. Mixed-model analysis of variance was performed to compare radial GRE and Cartesian VIBE. Radial GRE had significantly (all P < 0.001) higher scores for overall image quality, hepatic edge sharpness, hepatic vessel clarity and respiratory motion robustness than Cartesian VIBE. More lesions were detected on radial GRE by both readers than on Cartesian VIBE, with significantly higher scores for lesion conspicuity and edge sharpness (all P < 0.001). Radial GRE has better image quality and lesion conspicuity than conventional Cartesian VIBE in paediatric patients undergoing contrast-enhanced abdominopelvic MRI. (orig.)

  12. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S. [Univ. Hospital of Regensburg (Germany). Dept. of Diagnostic Radiology; Stamato, S. [Univ. of California, San Diego, CA (United States). Dept. of Radiology

    2002-07-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

  13. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S.; Stamato, S.

    2002-01-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage

  14. Enhancement of electrochemical performance of LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 by surface modification with MnO_2

    International Nuclear Information System (INIS)

    Guo, Xin; Cong, Li-Na; Zhao, Qin; Tai, Ling-Hua; Wu, Xing-Long; Zhang, Jing-Ping; Wang, Rong-Shun; Xie, Hai-Ming; Sun, Li-Qun

    2015-01-01

    LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 is successfully coated with MnO_2 by a chemical deposition method. The X-ray diffraction (XRD), scanning electron microscope (SEM) and high resolution transmission electron microscope (HRTEM) results demonstrate that MnO_2 forms a thin layer on the surface of LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 without destroying the crystal structure of the core material. Compared with pristine LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2, the MnO_2-coated sample shows enhanced electrochemical performance especially the rate capability. Even at a current density of 750 mA g"−"1, the discharge capacity of MnO_2-coated LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 is 155.15 mAh g"−"1, while that of the pristine electrode is only 132.84 mAh g"−"1 in the range of 2.5–4.5 V. The cyclic voltammetry (CV) and X-ray photoelectron spectroscopy (XPS) curves show that the MnO_2 coating layer reacts with Li"+ during cycling, which is responsible for the higher discharge capacity of MnO_2-coated LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2. Electrochemical impedance spectroscopy (EIS) results confirmed that the MnO_2 coating layer plays an important role in reducing the charge transfer resistance on the electrolyte–electrode interfaces. - Highlights: • MnO_2 coated LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 cathode material is synthesized for the first time. • MnO_2 offers available sites for insertion of extracted lithium. • The preserved surface and crystal structures results in the improved kinetics.

  15. Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.0 Tesla

    International Nuclear Information System (INIS)

    Lavdas, Eleftherios; Vlychou, Marianna; Arikidis, Nikos; Kapsalaki, Eftychia; Roka, Violetta; Fezoulidis, Ioannis V.

    2010-01-01

    Background: T1-weighted fluid-attenuated inversion recovery (FLAIR) sequence has been reported to provide improved contrast between lesions and normal anatomical structures compared to T1-weighted fast spin-echo (FSE) imaging at 1.5T regarding imaging of the lumbar spine. Purpose: To compare T1-weighted FSE and fast T1-weighted FLAIR imaging in normal anatomic structures and degenerative and metastatic lesions of the lumbar spine at 3.0T. Material and Methods: Thirty-two consecutive patients (19 females, 13 males; mean age 44 years, range 30-67 years) with lesions of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted FSE and fast T1-weighted FLAIR sequences. Both qualitative and quantitative analyses measuring the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and relative contrast (ReCon) between degenerative and metastatic lesions and normal anatomic structures were conducted, comparing these sequences. Results: On quantitative evaluation, SNRs of cerebrospinal fluid (CSF), nerve root, and fat around the root of fast T1-weighted FLAIR imaging were significantly lower than those of T1-weighted FSE images (P<0.001). CNRs of normal spinal cord/CSF and disc herniation/ CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). ReCon of normal spinal cord/CSF, disc herniation/CSF, and vertebral lesions/CSF for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted FSE images (P<0.001). On qualitative evaluation, it was found that CSF nulling and contrast at the spinal cord (cauda equina)/CSF interface for T1-weighted FLAIR images were significantly superior compared to those for T1-weighted FSE images (P<0.001), and the disc/spinal cord (cauda equina) interface was better for T1-weighted FLAIR images (P<0.05). Conclusion: The T1-weighted FLAIR sequence may be considered as the preferred lumbar spine imaging

  16. MR imaging findings of diffuse axonal injury: comparison of T2-weighted gradient images and T1- and T2-weighted spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seo Young; Lee, Ghi Jai; Kim, Jeong Seok; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To compare T2-weighted images with spin-echo T1- and turbo spin-echo (TSE) T2-weighted images in patients with diffuse axonal injury(DAI). Using a 1.0T MR unit, SE T1-, TSE T2-, and and FLASH T2-weighted images were obtained from 69 patients with a history of head trauma. In 18MR images of 17 patients with imaging findings of DAI, T2-weighted images were retrospectively compared with SE T1- and TSE T2-weighted images. The interval between trauma and MR scan varied from 5 days to 24(mean, 11) months. Focusing on the number of lesions, and their location and signal intensity, as weel as associated findings, three images were simultaueously evaluated. In 18 MR images of 17 patients with MR imaging findings of DAI, 21 lesions were detected on T1-weighted images, 28 on TSE T2-weighted images, and 70 on T2-weighted images;the last of these revealed all lesions detected on the other two. Most lesions were hypointense on T1-weighted images(17/21), hyperintense on TSE T2-weighted (21/28), and hypointense on T2-weighted (63/70). Common locations for DAI were the frontal lobe (n=3D35) and corpus callosum (n=3D22). Associated brain injuries were cortical contusion (n=3D5), brainstem injury (n=3D3), deep gray matter injury (n=3D2), and subdural hematoma(n=3D1). In patients with DAI. T2-weighted images can detect more lesions and associated petechial hemorrhage than can TSE T2-weighted images. This modality is thus useful for the evaluation of patients with head trauma.=20.

  17. Mn induced ferromagnetism spin fluctuation enhancement in Sr{sub 2}Ru{sub 1−x}Mn{sub x}O{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Long; Cai, Jinzhu; Xie, Qiyun; Lv, Bin [Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China); Mao, Z.Q. [Department of Physics and Engineering Physics, Tulane University, New Orleans, LA 70118 (United States); Wu, X.S., E-mail: xswu@nju.edu.cn [Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China)

    2013-09-15

    We establish that Sr{sub 2}RuO{sub 4} is extremely close to incommensurate spin density wave instability. With increasing Mn content, the RuO{sub 6} octahedron in the unit cell varies. The octahedron of RuO{sub 6} contracts along c-axis for x<0.20, Mn element mainly showing the +3 chemical valence (Mn{sup 3+}), and it expands along c-axis with further increasing Mn content (x>0.20), and Mn element shows the +4 chemical valence (Mn{sup 4+}). Spin-glass-related ferromagnetism enhancement is observed for x>0.20, which indicates the critical ferromagnetic spin fluctuation due to Mn doping in Sr{sub 2}Ru{sub 1−x}Mn{sub x}O{sub 4}. - Highlights: • The chemical valence of Mn ions changed from Mn{sup 3+} to Mn{sup 4+} with the increase of Mn content. • Spin-glass-related ferromagnetism enhancement behavior is observed. • The electrical resistivity can be fitted using Mott's variable-range hopping model. • The evolution of octahedron with increase of Mn content is given. • The spin fluctuation effect plays an important role in the magnetic property.

  18. MR imaging pulse sequence rationale: SD-, T1-, and T2-weighted images

    International Nuclear Information System (INIS)

    Sax, S.; Weathers, S.W.; Schneiders, N.J.; Horowitz, B.L.; Mawad, M.E.; Sandlin, M.E.; Blackwell, R.; Bryan, R.N.

    1986-01-01

    Over 500 patients have been examined with a pulse sequence designed to provide spin-density (SD)-weighted images (TR=3 sec, TE=35 msec), T1-weighted images (TR=0.3 sec, TE=35msec), and T2-weighted images (TR=3 sec, TE=105 msec) from which calculated ''synthesized'' images and SD, T1, and T2 calculated images could be obtained. Each image contributes unique information. SD-weighted images optimally display anatomy and often best highlight pathology. T1-weighted images are critical in assessing cerebral hemorrhages. T2-weighted images best display most lesions, but yield incomplete information in 35% of cases. All three types of ''weighted'' images are necessary to optimally display anatomy and fully characterize a lesion. Computerized calculations and simulations suggest that no other combination of pulse sequences yields equal information for a given examination time

  19. Diagnostic Utility of Contrast-enhanced 3D T1-weighted Imaging in Acute Cerebral Infarction Associated with Graves Disease.

    Science.gov (United States)

    Gon, Yasufumi; Sakaguchi, Manabu; Oyama, Naoki; Mochizuki, Hideki

    2017-02-01

    Graves disease is rarely complicated with cerebrovascular steno-occlusive diseases. Previous studies have suggested several hypotheses for this occurrence, including excess thyroid hormone, which stimulates the sympathetic nervous system, which in turn causes an abnormal hemodynamic response with consequent atherosclerotic changes, and antithyroid antibodies cause local vascular inflammation in patients with Graves disease. However, radiological findings of vasculitis in patients with Graves disease and cerebral infarction remain less known. We report the case of a 30-year-old Japanese woman with acute cerebral infarction due to vasculitis associated with Graves disease. She was admitted to our hospital with a 4-day history of intermittent transient dysarthria and limb shaking of the left leg when standing. Three weeks before admission, she went to a local hospital because of general malaise and was diagnosed with Graves disease. Neurological examination revealed paralytic dysarthria, left central facial nerve palsy, and left hemiparesis (manual muscle testing, 4 of 5). Blood examinations showed hyperthyroidism (thyroid-stimulating hormone ≤.010 µU/mL; free T3 ≥25.0 pg/mL; free T4 ≥8.0 ng/dL) and elevation of antithyroid antibody levels (thyroid peroxidase antibody, 87 IU/mL). The vessel wall of the right internal carotid artery was markedly enhanced on contrast-enhanced three-dimensional T1-weighted magnetic resonance imaging, suggesting vasculitis. Magnetic resonance angiography revealed right internal carotid artery occlusion after the branching ophthalmic artery. Arterial stenosis due to vasculitis was considered the cause of hemodynamic ischemic stroke. Vessel wall imaging such as high-resolution contrast-enhanced T1-weighted imaging seems useful for assessing the underlying mechanism of stroke in patients with Graves disease. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Science.gov (United States)

    Huang, Meiyan; Yang, Wei; Wu, Yao; Jiang, Jun; Gao, Yang; Chen, Yang; Feng, Qianjin; Chen, Wufan; Lu, Zhentai

    2014-01-01

    This study aims to develop content-based image retrieval (CBIR) system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR) images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW) model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML) is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor). Using the BoVW model with partition learning, the mean average precision (mAP) of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  1. Content-based image retrieval using spatial layout information in brain tumor T1-weighted contrast-enhanced MR images.

    Directory of Open Access Journals (Sweden)

    Meiyan Huang

    Full Text Available This study aims to develop content-based image retrieval (CBIR system for the retrieval of T1-weighted contrast-enhanced MR (CE-MR images of brain tumors. When a tumor region is fed to the CBIR system as a query, the system attempts to retrieve tumors of the same pathological category. The bag-of-visual-words (BoVW model with partition learning is incorporated into the system to extract informative features for representing the image contents. Furthermore, a distance metric learning algorithm called the Rank Error-based Metric Learning (REML is proposed to reduce the semantic gap between low-level visual features and high-level semantic concepts. The effectiveness of the proposed method is evaluated on a brain T1-weighted CE-MR dataset with three types of brain tumors (i.e., meningioma, glioma, and pituitary tumor. Using the BoVW model with partition learning, the mean average precision (mAP of retrieval increases beyond 4.6% with the learned distance metrics compared with the spatial pyramid BoVW method. The distance metric learned by REML significantly outperforms three other existing distance metric learning methods in terms of mAP. The mAP of the CBIR system is as high as 91.8% using the proposed method, and the precision can reach 93.1% when the top 10 images are returned by the system. These preliminary results demonstrate that the proposed method is effective and feasible for the retrieval of brain tumors in T1-weighted CE-MR Images.

  2. Metastatic spinal tumor. Assessment with fat-saturation T1-weighted MR imaging

    International Nuclear Information System (INIS)

    Kasai, Toshifumi; Sugimura, Kazuro; Uchida, Nobue; Kawamitsu, Hideaki; Komatsu, Akio; Okui, Shouji; Kimino, Katsuji.

    1994-01-01

    The purpose of this study was to compare conventional T1-weighted imaging (T1-WI) and chemical shift fat-saturation T1-weighted imaging (fat-sat T1-WI) by a diagnosis of the bone metastases. Thirty-two patients (143 vertebrae) with non-neoplastic lesions (normal group) and 32 patients (82 vertebrae) with spinal metastases (metastatic group) were evaluated using both images. The signal intensity (SI) distribution of both groups regarding T1-WI provided various patterns, and the SI measurements were not significantly different between the two groups ; however, the metastases which were mixed, showed a low SI. Regarding fat-sat T1-WI, all non-neoplastic lesions had a low-intensity homogeneous appearance ; however, the metastases were mixed to a high SI. The SI measurement data of the metastatic group was significantly higher than that of the normal group. In conclusion, fat-sat T1-WI was useful for evaluating the vertebral metastases. When fat-sat T1-WI demonstrated a mixed to high SI in patients suspected of having vertebral metastasis, Gd-DTPA enhancement was thought to be the problem. (author)

  3. Neutron investigation of Ru-doped Nd1/2Ca1/2MnO3. Comparison with Cr-doped Nd1/2Ca1/2MnO3

    International Nuclear Information System (INIS)

    Moritomo, Yutaka; Nonobe, Toshihiko; Machida, Akihiko; Ohoyama, Kenji

    2002-01-01

    Lattice and magnetic properties are investigated for 3% Ru- and Cr-doped Nd 1/2 Ca 1/2 MnO 3 . The parent Nd 1/2 Ca 1/2 MnO 3 is a charge-ordered insulator (T CO =250K). With decreasing temperature below ≅210K, these compounds are separated into two perovskite phases, that is, the long-c and short-c phases. The long-c region shows a ferromagnetic transition at T C ≅210K for the Ru-doped compound and ≅130K for the Cr-doped compound, while the short-c region shows antiferromagnetic transition at T N ≅150K for Ru and ≅110K for Cr. We discuss the origin of the enhanced T C for the Ru-doped compound in terms of the effective one-electron bandwidth W of the e g -band. (author)

  4. Intraindividual comparison of myocardial delayed enhancement MR imaging using gadobenate dimeglumine at 1.5 T and 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, Bernhard D.; Seeger, Achim; Fenchel, Michael; Kramer, Ulrich; Claussen, Claus D.; Miller, Stephan [Eberhard Karls University Tuebingen, Department for Diagnostic Radiology, Tuebingen (Germany); Sandstede, Joern [Roentgenzentrum, Hamburg (Germany); Lodemann, Klaus P. [Bracco Altana Pharma, Konstanz (Germany); Hoevelborn, Tobias [Eberhard Karls University Tuebingen, Department for Cardiology, Tuebingen (Germany)

    2009-05-15

    For contrast-enhanced imaging techniques relying on strong T1 weighting, 3 T provides increased contrast compared with 1.5 T. The aim of our study was the intraindividual comparison of delayed enhancement MR imaging at 1.5 T and at 3 T. Twenty patients with myocardial infarction were examined at 1.5 T and 3 T. Fifteen minutes after injection of contrast agent (0.1 mmol gadobenate dimeglumine per kg body weight), inversion recovery gradient recalled echo (IR-GRE) sequences were acquired (1.5 T/3 T: TR 11.0/9.9 ms, TE 4.4/4.9 ms, flip 30 /30 , slice thickness 6/6 mm) to assess myocardial viability. Two observers rated image quality (Wilcoxon signed rank test). Quantification of hyperenhanced myocardium and standardized SNR/CNR measurements were performed (Student's t test). There was no significant difference with respect to image quality (1.5 T/3 T: 3.5/3.3, p = 0.34, reader 1; 2.4/2.7, p = 0.12, reader 2) and infarction size (760 {+-} 566/828 {+-} 677 mm{sup 2} at 1.5 T, 808 {+-} 639/826 {+-} 726 mm{sup 2} at 3 T, reader 1/reader 2, p > 0.05). Mean SNR in hyperenhanced/normal myocardium was 19.2/6.2 at 1.5 T and 29.5/8.8 at 3 T (p < 0.05). Mean CNR was 14.3 at 1.5 T and 26.0 at 3 T (p < 0.05). Delayed enhancement MR imaging at 3 T is a robust procedure yielding superior tissue contrast at 3 T compared with 1.5 T which is, however, not reflected by increased image quality. (orig.)

  5. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  6. Craniopharyngiomas - the utility of contrast medium enhancement for MR imaging at 1.5 T

    International Nuclear Information System (INIS)

    Hald, J.K.; Eldevik, O.P.; Brunberg, J.A.; Chandler, W.F.

    1994-01-01

    To evaluate the efficacy of i.v. contrast medium administration in MR imaging at 1.5 T in patients with craniopharyngiomas, MR studies of 10 men and 6 women with pathologically proven craniopharyngiomas were made. The MR images were obtained as 3- to 5-mm-thick coronal (n=13) or axial (n=3) T1-weighted images (T1WI) prior to an following i.v. Gd-DTPA administration. Proton density-(PD) and T2-weighted images (T2WI) were also obtained. Conspicuity of tumor margins, cystic versus solid components, size, location and effect upon adjacent structures were separately characterized in all imaging sequences. In 6 patients contrast medium-enhanced T1WI, PD and T2WI demonstrated cystic tumor components not seen on unenhanced T1WI. There were significant differences (p<0.004) on 2-tailed Student's t-test comparing tumor conspicuity on contrast medium-enhanced T1WI with unenhanced T1WI, PD and T2WI. Optimal tumor delineation on MR imaging of patients with craniopharyngiomas justifies the use of i.v. contrast medium. (orig.)

  7. Manganese dipyridoxyl diphosphate:

    DEFF Research Database (Denmark)

    H, Brurok; Ardenkjær-Larsen, Jan Henrik; G, Hansson

    1999-01-01

    Manganese dipyridoxyl diphosphate (MnDPDP) is a contrast agent for magnetic resonance imaging (MRI) of the liver. Aims of the study were to examine if MnDPDP possesses superoxide dismutase (SOD) mimetic activity in vitro, and if antioxidant protection can be demonstrated in an ex vivo rat heart...

  8. Gadolinium-enhanced MR imaging of normal renal transplants. An evaluation of a T1-weighted dynamic echo-planar sequence

    International Nuclear Information System (INIS)

    Dupas, B.; Blancho, G.; Havet, T.; Leaute, F.

    1999-01-01

    Purpose: To evaluate the potential usefulness of dynamic MR with echoplanar imaging (EPI) in assessing the renal function in patients with renal allografts. Material and methods: Using a T1-weighted sequence, EPI was performed after injection of a Gd-chelate in 17 patients with normally functioning renal allografts. Time-intensity curves were plotted from the signal intensity (SI) measurements of the cortex and the medulla. Results: The pattern of corticomedullar differentiation (CMD) observed after constrast enhancement was divided into four phases using the T1-EPI. After a rapid decrease in the SI of cortical structures, and a subsequent return to precontrast levels, a gradual fall in the SI of the medulla was observed. The average time between the two periods of signal loss was 60 s. Conclusion: This study illustrated the potential use of dynamic T1-EPI to demonstrate contrast-induced CMD in renal allografts. (orig.)

  9. The usefulness of T2-weighted MR urography and contrast enhanced MR urography in the evaluation of obstructive uropathy: comparisonal study with antegrade pyelography

    International Nuclear Information System (INIS)

    Oh, Chang Hoon; Lee, Jeong Min; Jin, Kong Yong; Chung, Gyung Ho; Cho, Seung Il; Lee, Sang Hun; Kim, Young Kon; Oh, Gyung Jae

    2002-01-01

    To compare the efficacy of contrast-enhanced and T2-weighted magnetic resonance urography (MRU) for the depiction of obstruction and evaluation of the causes of obstructive uropathy with that of antegrade pyelography. Twenty-five patients with obstructive uropathy who underwent percutaneous nephrostomy (PCN) and antegrade pyelography( AGP) were included in the study. We performed MR urography, comprising half-Fourier acquisition single-shot turbo spin-echo (HASTE) T2- weighted imaging and 3-D fast imaging with steady state precession (3-D FISP) T1-weighted imaging after gadolinium enhancement and compared the quality of the images of both the HASTE and 3-D FISP MRU technique in terms of their depiction of the dilated pelvocalyceal system, and the level, type, and causes of obstruction. In terms of anatomical depiction of the pelvocalyceal system (p=0.002) and the causes of obstruction (p=0.003). T1-weighted MRU using 3D-FISP was significantly better than T2-weighted MRU using the HASTE sequence. Regarding level of obstruction, T2-weighted MRU using the HASTE sequence and contrast enhanced T1-weighted MRU using 3D-FISP showed an accuracy of 76% (19/25) and 84% (21/25), respectively. In terms of type of obstruction, the accuracy of T2-weighted MRU and T1-weighted CEMRU was 72% (18/25) and 88% (22/25), respectively. T2-weighted MRU and Ta-weighted CEMRU provided both anatomical information and that relating to impaired renal function. The two modelities played a complementary role and their use could decrease the unnecessary use of invasive diagnostic examination for the evaluation of obstructive uropathy

  10. T2-enhanced tensor diffusion trace-weighted image in the detection of hyper-acute cerebral infarction: Comparison with isotropic diffusion-weighted image

    International Nuclear Information System (INIS)

    Chou, M.-C.; Tzeng, W.-S.; Chung, H.-W.; Wang, C.-Y.; Liu, H.-S.; Juan, C.-J.; Lo, C.-P.; Hsueh, C.-J.; Chen, C.-Y.

    2010-01-01

    Background and purpose: Although isotropic diffusion-weighted imaging (isoDWI) is very sensitive to the detection of acute ischemic stroke, it may occasionally show diffusion negative result in hyper-acute stroke. We hypothesize that high diffusion contrast diffusion trace-weighted image with enhanced T2 may improve stroke lesion conspicuity. Methods: Five hyper acute stroke patients (M:F = 0:5, average age = 61.8 ± 20.5 y/o) and 16 acute stroke patients (M:F = 11:5, average age = 67.7 ± 12 y/o) were examined six-direction tensor DWIs at b = 707 s/mm 2 . Three different diffusion-weighted images, including isotropic (isoDWI), diffusion trace-weighted image (trDWI) and T2-enhanced diffusion trace-weighted image (T2E t rDWI), were generated. Normalized lesion-to-normal ratio (nLNR) and contrast-to-noise ratio (CNR) of three diffusion images were calculated from each patient and statistically compared. Results: The trDWI shows better nLNR than isoDWI on both hyper-acute and acute stroke lesions, whereas no significant improvement in CNR. Nevertheless, the T2E t rDWI has statistically superior CNR and nLNR than those of isoDWI and trDWI in both hyper-acute and acute stroke. Conclusions: We concluded that tensor diffusion trace-weighted image with T2 enhancement is more sensitive to stroke lesion detection, and can provide higher lesion conspicuity than the conventional isotropic DWI for early stroke lesion delineation without the need of high-b-value technique.

  11. Differentiating benign and malignant breast lesions with T2*-weighted first pass perfusion imaging

    International Nuclear Information System (INIS)

    Kvistad, K.A.; Smenes, E.; Haraldseth, O.; Lundgren, S.; Fjoesne, H.E.; Smethurst, H.B.

    1999-01-01

    Purpose: Invasive breast carcinomas and fibroadenomas are often difficult to differentiate in dynamic contrast-enhanced T1-weighted MR imaging of the breast, because both tumors can enhance strongly after contrast injection. The purpose of this study was to evaluate whether the addition of T2*-weighted first pass perfusion imaging can increase the differentiation of malignant from benign lesions. Material and Methods: Nine patients with invasive carcinomas and 10 patients with contrast enhancing fibroadenomas were examined by a dynamic contrast-enhanced T1-weighted 3D sequence immediately followed by a single slice T2*-weighted first pass perfusion sequence positioned in the contrast-enhancing lesion. Results: The carcinomas and the fibroadenomas were impossible to differentiate based on the contrast enhancement characteristics in the T1-weighted sequence. The signal loss in the T2*-weighted perfusion sequence was significantly stronger in the carcinomas than in the fibroadenomas (p=0.0004). Conclusion: Addition of a T2*-weighted first pass perfusion sequence with a high temporal resolution can probably increase the differentiation of fibroadenomas from invasive carcinomas in contrast-enhanced MR imaging of the breast. (orig.)

  12. Multimodal diagnosis of multiple and heterogeneous liver lesions in a young patient; Multimodale Bildgebung multipler Leberlaesionen bei einem jungen Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, F.; Schlemmer, H.-P. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany). Abteilung fuer onkologische Diagnostik und Therapie

    2005-10-01

    The classification of liver lesions is often problematic in particular if they are multiple and show an heterogeneous shape. Here we report of a young patient with multiple liver lesions of up to 3 cm size. Using ultrasound, the lesions were hyper-, hypoechogen or mixed. In serial contrast enhanced CT scans some of the lesions showed the typical enhancement pattern of hemangiomas, however, the diagnosis could still not be faithfully determined for all lesions. Therefore, the patient was conducted to contrast enhanced MRI (Gd-DTPA and MnDPDP). While with Gd-DTPA some of the lesions showed a strong enhancement, they remained hypointense after administration of MnDPDP. Finally to exclude a metastatic disease a {sup 99m}Tc-erythrocyte SPECT was performed confirming the diagnosis of hemangiomas for most of the lesions. Diagnosis was not assessed by biopsy because this would only clarify the diagnosis for one or few of the lesions. The patient was subsequently followed up for 3 years and all lesions remained unchanged. This case clearly illustrates the difficulty to get a certain diagnosis of multiple liver lesions with heterogeneous appearance despite the multimodal diagnostic conduct. (orig.) [German] Bei einer Routineuntersuchung wurden bei einem jungen Patienten sonographisch multiple Leberrundherde mit hyper-, hypoechogener und gemischter Echogenitaet detektiert. Auch mittels triphasischer kontrastmittelverstaerkter CT gelang nur bei einem Teil der Herde die Einstufung als Haemangiome anhand ihres Irisblendenphaenomens. MRT-Untersuchungen unter Verwendung von Gd-DTPA und MnDPDP wurden angeschlossen. Mit Gd-DTPA zeigten einige Herde ein kraeftiges Enhancement, unter Verwendung von MnDPDP jedoch blieben sie hypointens. Auf eine Biopsie wurde verzichtet, da diese nur bei einem oder wenigen Herden die Diagnose liefern wuerde, die anderen Herde aber unter Beruecksichtigung ihrer Heterogenitaet unklar geblieben waeren. Eine Sicherung der Diagnose gelang fuer die meisten

  13. Fat suppression at three-dimensional T1-weighted MR imaging of the hands: Dixon method versus CHESS technique.

    Science.gov (United States)

    Kirchgesner, T; Perlepe, V; Michoux, N; Larbi, A; Vande Berg, B

    2018-01-01

    To compare the effectiveness of fat suppression and the image quality of the Dixon method with those of the chemical shift-selective (CHESS) technique in hands of normal subjects at non-enhanced three-dimensional (3D) T1-weighted MR imaging. Both hands of 14 healthy volunteers were imaged with 3D fast spoiled gradient echo (FSPGR) T1-weighted Dixon, 3D FSPGR T1-weighted CHESS and 3D T1-weighted fast spin echo (FSE) CHESS sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the signal-to-noise ratio (SNR) in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects (PCHESS sequence and the 3D FSE T1-weighted CHESS sequence (PCHESS sequence (PCHESS sequence in the axial plane (P=0.0028). Mean SNR was statistically significantly higher for 3D FSPGR T1-weighted Dixon sequence than for 3D FSPGR T1-weighted CHESS and 3D FSE T1-weighted CHESS sequences (PCHESS technique at 3D T1-weighted MR imaging of the hands. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  14. Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Miyake, Mototaka; Sakurada, Aine; Arai, Yasuaki; Tsurusaki, Masakatsu; Sugimura, Kazuro

    2010-01-01

    To prospectively compare the diagnostic performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging at 3.0 T and 1.5 T for detection of hepatic metastases. A total of 28 patients (18 men, 10 women; mean age, 61 years) with 80 hepatic metastases were prospectively examined by SPIO-enhanced MR imaging at 3.0 T and 1.5 T. T1-weighted gradient-recalled-echo (GRE) images, T2*-weighted GRE images and T2-weighted fast spin-echo (SE) images were acquired. The tumour-to-liver contrast-to-noise ratio (CNR) of the lesions was calculated. Three observers independently reviewed each image. Image artefacts and overall image quality were analysed, sensitivity and positive predictive value for the detection of hepatic metastases were calculated, and diagnostic accuracy using the receiver-operating characteristics (ROC) method was evaluated. The tumour-to-liver CNRs were significantly higher at 3.0 T. Chemical shift and motion artefact were more severe, and overall image quality was worse on T2-weighted fast SE images at 3.0 T. Overall image quality of the two systems was similar on T1-weighted GRE images and T2*-weighted GRE images. Sensitivity and area under the ROC curve for the 3.0-T image sets were significantly higher. SPIO-enhanced MR imaging at 3.0 T provided better diagnostic performance for detection of hepatic metastases than 1.5 T. (orig.)

  15. Hilar branching anatomy of living adult liver donors: comparison of T2-MR cholangiography and contrast enhanced T1-MR cholangiography in terms of diagnostic utility

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Kim, Myeong Jin; Kim, Kyung Sik; Kim, Joo Hee; Oh, Young Taik; Kim, Jin Yong; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2004-01-01

    To compare T2-weighted MR cholangiography (T2-MRC) and contrast-enhanced T1-weighted MRC (enhanced T1-MRC) in the assessment of biliary anatomy in donor candidates for living related liver transplantation (LRLT). Thirty-three potential donors underwent MR examination for preoperative evaluation. Using the single-shot half-Fourier RARE sequence, T2-weighted single-section and coronal images were obtained, and enhanced T1-MRC was performed, using 3D GRE sequences after the administration of mangafodifir trisodium. To assess the hilar ductal branching pattern and determine diagnostic confidence, two reviewers first evaluated the unpaired T2-MRC and enhanced T1-MRC images, and then paired T2-MRC and enhanced T1-MRC images together. In particular, in 12 cases in which direct cholangiographys were performed, the feasibility of single duct-to-duct anastomosis was assessed using the unpaired and the paired sets sequentially. The reviewers, confidence tended to be higher for enhanced T1-MRC than T2-MRC, but the difference was not statistically significant. For both reviewers, confidence was significantly higher for the paired set than for T2- or enhanced T1-MRC alone (p<0.001). The types of biliary anatomy determined in the paired set matched the consensus reading in 33 (100%) and 30 cases(91%) assessed by reviewer 1 and 2, respectively. The separate interpretation of T2- and enhanced T1-MRC findings matched the consensus interpretation in 30 (91%) and 28 cases (85%), respectively, assessed by reviewer 1, and 26 (79%) and 28 cases (85%), respectively, assessed by reviewer 2. The possibility of single anastomosis was accurately predicted in 91.6% of cases in T2-MRC, and 100% at enhanced T1-MRC and the combined set. In the evaluation of the biliary anatomy of potential donors for LRLT, the combined use of T2-MRC and enhanced T1-MRC may improve diagnostic confidence and decrease the occurrence of a non diagnostic or equivocal interpretation at T2-MRC alone

  16. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    International Nuclear Information System (INIS)

    Erdem, L. Oktay; Erdem, C. Zuhal; Acikgoz, Bektas; Gundogdu, Sadi

    2005-01-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times

  17. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, L. Oktay [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)]. E-mail: sunarerdem@yahoo.com; Erdem, C. Zuhal [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey); Acikgoz, Bektas [Department of Neurosurgery, Zonguldak Karaelmas University, School of Medicine, Zonguldak (Turkey); Gundogdu, Sadi [Department of Radiology, Zonguldak Karaelmas University, School of Medicine, 6700 Kozlu, Zonguldak (Turkey)

    2005-08-01

    Objective: To compare fast T1-weighted fluid-attenuated inversion recovery (FLAIR) and T1-weighted turbo spin-echo (TSE) imaging of the degenerative disc disease of the lumbar spine. Materials and methods: Thirty-five consecutive patients (19 females, 16 males; mean age 41 years, range 31-67 years) with suspected degenerative disc disease of the lumbar spine were prospectively evaluated. Sagittal images of the lumbar spine were obtained using T1-weighted TSE and fast T1-weighted FLAIR sequences. Two radiologists compared these sequences both qualitatively and quantitatively. Results: On qualitative evaluation, CSF nulling, contrast at the disc-CSF interface, the disc-spinal cord (cauda equina) interface, and the spinal cord (cauda equina)-CSF interface of fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.001). On quantitative evaluation of the first 15 patients, signal-to-noise ratios of cerebrospinal fluid of fast T1-weighted FLAIR imaging were significantly lower than those for T1-weighted TSE images (P < 0.05). Contrast-to-noise ratios of spinal cord/CSF and normal bone marrow/disc for fast T1-weighted FLAIR images were significantly higher than those for T1-weighted TSE images (P < 0.05). Conclusion: Results in our study have shown that fast T1-weighted FLAIR imaging may be a valuable imaging modality in the armamentarium of lumbar spinal T1-weighted MR imaging, because the former technique has definite superior advantages such as CSF nulling, conspicuousness of the normal anatomic structures and changes in the lumbar spinal discogenic disease and image contrast and also almost equally acquisition times.

  18. Assessment of Silent T1-weighted head imaging at 7 T

    Energy Technology Data Exchange (ETDEWEB)

    Costagli, Mauro; Tiberi, Gianluigi; Tosetti, Michela [Imago7 Foundation, Pisa (Italy); IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Symms, Mark R. [GE Applied Science Laboratory, Pisa (Italy); Angeli, Lorenzo [University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Kelley, Douglas A.C. [GE Healthcare Technologies, San Francisco, CA (United States); Biagi, Laura [IRCCS Stella Maris, Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, Pisa (Italy); Farnetani, Andrea [University of Ferrara, Engineering Department, Ferrara (Italy); Materiacustica s.r.l., Ferrara (Italy); Rua, Catarina [University of Pisa, Department of Physics, Pisa (Italy); Donatelli, Graziella [Azienda Ospedaliero-Universitaria Pisana (AOUP), Neuroradiology Unit, Department of Diagnostic and Interventional Radiology, Pisa (Italy); Cosottini, Mirco [Imago7 Foundation, Pisa (Italy); University of Pisa, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy)

    2016-06-15

    This study aimed to assess the performance of a ''Silent'' zero time of echo (ZTE) sequence for T1-weighted brain imaging using a 7 T MRI system. The Silent sequence was evaluated qualitatively by two neuroradiologists, as well as quantitatively in terms of tissue contrast, homogeneity, signal-to-noise ratio (SNR) and acoustic noise. It was compared to conventional T1-weighted imaging (FSPGR). Adequacy for automated segmentation was evaluated in comparison with FSPGR acquired at 7 T and 1.5 T. Specific absorption rate (SAR) was also measured. Tissue contrast and homogeneity in Silent were remarkable in deep brain structures and in the occipital and temporal lobes. Mean tissue contrast was significantly (p < 0.002) higher in Silent (0.25) than in FSPGR (0.11), which favoured automated tissue segmentation. On the other hand, Silent images had lower SNR with respect to conventional imaging: average SNR of FSPGR was 2.66 times that of Silent. Silent images were affected by artefacts related to projection reconstruction, which nevertheless did not compromise the depiction of brain tissues. Silent acquisition was 35 dB(A) quieter than FSPGR and less than 2.5 dB(A) louder than ambient noise. Six-minute average SAR was <2 W/kg. The ZTE Silent sequence provides high-contrast T1-weighted imaging with low acoustic noise at 7 T. (orig.)

  19. Comparison of contrast-enhanced T1-weighted and 3D constructive interference in steady state images for predicting outcome after hearing-preservation surgery for vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Kocaoglu, M.; Bulakbasi, N.; Ucoz, T.; Ustunsoz, B.; Tayfun, C.; Somuncu, I. [GATA Department of Radiology, 06018, Etlik, Ankara (Turkey); Pabuscu, Y. [Department of Radiology, Celal Bayar University, Manisa (Turkey)

    2003-07-01

    We compared contrast-enhanced T1-weighted and 3D constructive interference in steady state (CISS) sequences for demonstrating possible prognostic factors in hearing-preservation surgery for vestibular schwannoma. We studied 22 patients with vestibular schwannomas having hearing-preservation surgery. Postoperatively six (27%) had a facial palsy and eight (36%) had hearing loss. There was a significant correlation between the size of the tumour and facial palsy (r=-0.72). Both techniques adequately demonstrated all tumours. Involvement of the fundus of the internal auditory canal (IAC) and a small distance between the lateral border of the tumour and the fundus were correlated significantly with hearing loss (r=-0.81 and -0.75, respectively). The 3D-CISS sequence, by virtue of its high contrast resolution was superior to T1-weighted images (P<0.05) for detection of the fundal involvement. The direction of displacement of the facial nerve did not correlate with facial palsy or hearing loss. We think that 3D-CISS images better show the features influencing surgical outcome, but that contrast-enhanced T1-weighted images are required for diagnosis. (orig.)

  20. Comparison of contrast-enhanced T1-weighted and 3D constructive interference in steady state images for predicting outcome after hearing-preservation surgery for vestibular schwannoma

    International Nuclear Information System (INIS)

    Kocaoglu, M.; Bulakbasi, N.; Ucoz, T.; Ustunsoz, B.; Tayfun, C.; Somuncu, I.; Pabuscu, Y.

    2003-01-01

    We compared contrast-enhanced T1-weighted and 3D constructive interference in steady state (CISS) sequences for demonstrating possible prognostic factors in hearing-preservation surgery for vestibular schwannoma. We studied 22 patients with vestibular schwannomas having hearing-preservation surgery. Postoperatively six (27%) had a facial palsy and eight (36%) had hearing loss. There was a significant correlation between the size of the tumour and facial palsy (r=-0.72). Both techniques adequately demonstrated all tumours. Involvement of the fundus of the internal auditory canal (IAC) and a small distance between the lateral border of the tumour and the fundus were correlated significantly with hearing loss (r=-0.81 and -0.75, respectively). The 3D-CISS sequence, by virtue of its high contrast resolution was superior to T1-weighted images (P<0.05) for detection of the fundal involvement. The direction of displacement of the facial nerve did not correlate with facial palsy or hearing loss. We think that 3D-CISS images better show the features influencing surgical outcome, but that contrast-enhanced T1-weighted images are required for diagnosis. (orig.)

  1. Hyperintense brain lesions on T1-weighted MRI after parenteral nutrition

    International Nuclear Information System (INIS)

    Saitoh, Yoshiaki; Kimura, Seiji; Nezu, Atsuo; Ohtsuki, Noriyuki; Kobayashi, Takuya; Osaka, Hitoshi; Uehara, Saori

    1996-01-01

    We experienced five children having T 1 -shortening lesions in basal ganglia or thalami on magnetic resonance imaging (MRI), which were supposed to be caused by manganese (Mn) overdoses. Instead of the presence of above-mentioned lesions, no neurological manifestations corresponding to them had developed in all patients. This observation suggests that MRI is useful for detecting side effects caused by overdoses of Mn in patients having parenteral nutrition. (author)

  2. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols

    DEFF Research Database (Denmark)

    Tofts, P.S.; Brix, G; Buckley, D.L.

    1999-01-01

    We describe a standard set of quantity names and symbols related to the estimation of kinetic parameters from dynamic contrast-enhanced T(1)-weighted magnetic resonance imaging data, using diffusable agents such as gadopentetate dimeglumine (Gd-DTPA). These include a) the volume transfer constant K......-limited conditions K(trans) equals the blood plasma flow per unit volume of tissue; under permeability-limited conditions K(trans) equals the permeability surface area product per unit volume of tissue. We relate these quantities to previously published work from our groups; our future publications will refer...

  3. Carcinoma of the uterine cervix. High-resolution turbo spin-echo MR imaging with contrast-enhanced dynamic scanning and T2-weighting

    International Nuclear Information System (INIS)

    Abe, Y.; Yamashita, Y.; Namimoto, T.; Takahashi, M.; Katabuchi, H.; Tanaka, N.; Okamura, H.

    1998-01-01

    Purpose: To compare high-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging with T2-weighted turbo spin-echo (TSE) imaging in the evaluation of uterine cervical carcinoma. Material and Methods: Thirty-two patients with cervical carcinoma underwent MR imaging on a 1.5 T superconductive unit to have the extension of the disease assessed before treatment. A phased-array coil was used in all patients. In 25 patients, surgical confirmation of the diagnosis was obtained after imaging. Radiation therapy was selected for the remaining 7 patients with advanced carcinoma. Qualitative and quantitative image analyses were also performed. Results: The cervical carcinomas showed maximum contrast in the cervical stroma and myometrium in the early dynamic phase. The tumor/cervical-stroma contrast in the early dynamic phase obtained with the T1-weighted TSE technique (contrast-to-noise ratio 22.6) was significantly higher than that obtained in T2-weighted TSE imaging (contrast-to-noise ratio 4.3). In the evaluation of parametrial invasion, the accuracy of T2-weighted imaging was 71.8% and contrast-enhanced dynamic imaging 81.2%. Conclusion: High-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging in cervical cancer offers improved tumor/cervical-stroma contrast and provides useful information on parametrial invasion. (orig.)

  4. Difference between T1 and T2 weighted MR images in avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo

    1990-01-01

    T 1 and T 2 weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T 2 weighted images than in T 1 weighted images. The area of low intensity on T 1 weighted image and high on T 2 weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T 1 and T 2 weighted images must be taken into consideration especially in determination of the border of affected bone. (author)

  5. Coupling between magnetic, dielectric properties and crystal structure in MnT2O4 (T = V, Cr, Mn)

    International Nuclear Information System (INIS)

    Suzuki, T; Adachi, K; Katsufuji, T

    2006-01-01

    We measured the temperature dependence of dielectric constant and striction for spinel MnT 2 O 4 (T = V, Cr, Mn) under magnetic field. We found critical changes of the dielectric constant and striction with ferrimagnetic ordering as well as applied magnetic field in MnV 2 O 4 and Mn 3 O 4 , which have orbital degree of freedom in the T 3+ ion. This result indicates the importance of the orbital degree of freedom for the coupling between dielectric, magnetic properties and crystal structure in these spinel compounds

  6. Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schubert, Tilman B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Basel University Hospital, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Said, Adnan [University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); Mezrich, Joshua D. [University of Wisconsin-Madison, Department of Surgery, Madison, WI (United States); Reeder, Scott B. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); University of Wisconsin-Madison, Department of Medicine, Madison, WI (United States); University of Wisconsin-Madison, Department of Biomedical Engineering, Madison, WI (United States); University of Wisconsin-Madison, Department of Medical Physics, Madison, WI (United States); University of Wisconsin-Madison, Department of Emergency Medicine, Madison, WI (United States)

    2017-10-15

    Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC). Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography (PTC) were analysed. Two readers reviewed the MRCs and rated image quality (IQ) and likelihood for AS/NAS/BC on Likert scales. Sensitivity, specificity and predictive values were calculated, ROC curve analysis performed, and inter-reader variability assessed. The subjective added value of T1w-MRC was rated. IQ was high for all sequences without significant differences (2.83-2.88). In 39 patients ERCP/PTC detected a complication. Sensitivity and specificity for AS were 64-96 using T2w-MRCP, increasing to 79-100 using all sequences. Use of all sequences increased the sensitivity of detecting NAS/BC from 72-92% to 88-100% and 67-89% to 72-94%, respectively. Kappa values were substantial (0.45-0.62). T1w-MRC was found to be helpful in 75-83.3%. Combining T1w-MRC and T2w-MRCP increased sensitivity and specificity and diagnostic confidence in patients after LT with suspected biliary complications. T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. (orig.)

  7. Radiation necrosis of the optic chiasm, optic tract, hypothalamus, and upper pons after radiotherapy for pituitary adenoma, detected by gadolinium-enhanced, T1-weighted magnetic resonance imaging: Case report

    International Nuclear Information System (INIS)

    Tachibana, O.; Yamaguchi, N.; Yamashima, T.; Yamashita, J.

    1990-01-01

    A 26-year-old woman was treated for a prolactin secreting pituitary adenoma by surgery and radiotherapy (5860 rads). Fourteen months later, she developed right hemiparesis and dysarthria. A T1-weighted magnetic resonance imaging scan using gadolinium contrast showed a small, enhanced lesion in the upper pons. Seven months later, she had a sudden onset of loss of vision, and radiation optic neuropathy was diagnosed. A T1-weighted magnetic resonance imaging scan showed widespread gadolinium-enhanced lesions in the optic chiasm, optic tract, and hypothalamus. Magnetic resonance imaging is indispensable for the early diagnosis of radiation necrosis, which is not visualized by radiography or computed tomography

  8. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Understanding the metabolic fate and assessing the biosafety of MnO nanoparticles by metabonomic analysis

    International Nuclear Information System (INIS)

    Li, Jinquan; Feng, Jianghua; Chen, Zhong; Zhao, Zhenghuan; Gao, Jinhao

    2013-01-01

    Recently, some types of MnO nanoparticle (Mn-NP) with favorable imaging capacity have been developed to improve the biocompatible profile of the existing Mn-based MRI contrast agent Mn-DPDP; however, the overall bio-effects and potential toxicity remain largely unknown. In this study, 1 H NMR-based metabolic profiling, integrated with traditional biochemical analysis and histopathological examinations, was used to investigate the absorption, distribution, metabolism, excretion and toxicity of Mn-NPs as candidates for MRI contrast agent. The metabolic responses in biofluids (plasma and urine) and tissues (liver, spleen, kidney, lung and brain) from rats could be divided into four classes following Mn-NP administration: Mn biodistribution-dependent, time-dependent, dose-dependent and complicated metabolic variations. The variations of these metabolites involved in lipid, energy, amino acid and other nutrient metabolism, which disclosed the metabolic fate and biological effects of Mn-NPs in rats. The changes of metabolic profile implied that the disturbance and impairment of biological functions induced by Mn-NP exposure were correlated with the particle size and the surface chemistry of nanoparticles. Integration of metabonomic technology with traditional methods provides a promising tool to understand the toxicological behavior of biomedical nanomaterials and will result in informed decision-making during drug development. (paper)

  10. Enhancement of Magnetocaloric Effect in ({ {La}}_{0.67}{ {Ca}}_{0.33}{ {MnO}}_{3})/({ {La}}_{0.7}{ {Ba}}_{0.3}{ {MnO}}_{3}) ( La 0.67 Ca 0.33 MnO 3 ) / ( La 0.7 Ba 0.3 MnO 3 ) Composite

    Science.gov (United States)

    Khelifi, J.; Dhahri, E.; Hlil, E. K.

    2018-03-01

    The composite (La_{0.67}Ca_{0.33}MnO3)/La_{0.7}Ba_{0.3}MnO3) sample was prepared using the conventional solid-state reaction method, and their crystallographic structure was achieved by X-ray diffraction pattern analysis. The magnetic and magnetocaloric effect has been studied by magnetization measurements. Based on the relation: χ ^{-1}(T)∝ (T-T_C^Rand )^{1-λ }, the inverse of susceptibility shows a downturn before T_C indicating the existence of Griffiths phase for the temperature range T_C^Randphase has been obtained from detailed magnetization studies. Furthermore, a large magnetic entropy change is observed in (La_{0.67}Ca_{0.33}MnO3)/(La_{0.7}Ba_{0.3}MnO3) composite which possesses a large MCE characterized by two Δ S_M(T) peaks. It has revealed that the combination of manganite materials with different Curie temperatures is a possible method for enhancement of magnetocaloric effect. To determine the field dependence of the experimental Δ S_M(T), a local exponent n( T, H) can be calculated from the logarithmic derivative of the magnetic entropy change versus field; it is shown that for a multiphase system n evolves with field both at the Curie temperature of the system and at the Curie temperatures of the constituent phases.

  11. Assessment of T2- and T1-weighted MRI brain lesion load in patients with subcortical vascular encephalopathy

    International Nuclear Information System (INIS)

    Gass, A.; Oster, M.; Cohen, S.; Daffertshofer, M.; Schwartz, A.; Hennerici, M.G.

    1998-01-01

    Previous cross-sectional studies in patients with subcortical vascular encephalopathy (SVE) have shown little or no correlation between brain lesion load and clinical disability, which could be due to the low specificity of T2-weighted MRI. Recent studies have indicated that T1-weighted MRI may be more specific than T2-weighted MRI for severe tissue destruction. We studied 37 patients with a diagnosis of SVE and 11 normal controls with standardised T1- and T2-weighted MRI. All patients underwent detailed clinical assessment including a neuropsychological test battery and computerised gait analysis. Both the T2- and T1-weighted total MRI lesion loads different between patients and controls different, particularly T1. The ratio of T2-/T1-weighted lesion load was lower in controls than in patients. There was no overall correlation of T1- or T2-weighted lesion load with clinical disability, but group comparison of patients with severe and mild clinical deficits showed different lesion loads. We suggest that T1- and T2-weighted MRI lesion loads demonstrate relevant structural abnormality in patients with SVE. (orig.)

  12. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  13. Enhanced moments in bcc Co{sub 1−x}Mn{sub x} on MgO(001)

    Energy Technology Data Exchange (ETDEWEB)

    Snow, R.J.; Bhatkar, H. [Department of Physics, Montana State University, Bozeman, MT 59715 (United States); N' Diaye, A.T.; Arenholz, E. [Advanced Light Source, Lawrence Berkeley Nat. Labs, Berkeley, CA 94720 (United States); Idzerda, Y.U., E-mail: Idzerda@montana.edu [Department of Physics, Montana State University, Bozeman, MT 59715 (United States)

    2016-12-01

    A 40% enhancement of the Co magnetic moment has been found for thin films of bcc Co{sub 1−x}Mn{sub x} grown by molecular beam epitaxy on a 2 nm bcc Fe buffer layer on MgO(001). Although the bcc phase cannot be stabilized in the bulk, we confirm that it is stable as an epitaxial film in the composition range x=0–0.7. Using X-ray absorption spectroscopy and X-ray magnetic circular dichroism, we show that the Co moment is a maximum of 2.38 μ{sub B} at x=0.24, while the net Mn moment remains roughly constant until x=0.24, then drops steadily. Mn is found to align parallel with Co for all ferromagnetic concentrations, up to x=0.7, where the total moment of the film abruptly collapses to zero, most likely due to the onset of the observed structural instability. - Highlights: • Stabilization of bcc Co{sub 1−x}Mn{sub x} films in the composition range of x=0 to 0.7. • Enhancement of Co moment by 40% from pure bcc Co. • Parallel alignment of Mn moment and Co moment. • Measured the elemental moment of Co and Mn as a function of composition.

  14. Are T2-weighted images necessary in renal mass characterization?

    International Nuclear Information System (INIS)

    Dann, Phoebe; Thakur, Ravi; Chin, Deanne; Krinsky, Glenn; Israel, Gary M.

    2006-01-01

    Objective: To determine what role T2-weighted images play in characterizing renal masses. Methods: Forty-four pathologically proven renal masses (34 renal cell carcinomas, 8 oncocytomas, 1 metanephric adenoma, 1 angiomyolipoma without macroscopic fat) and 38 simple renal cysts were evaluated with T1- and T2-weighted images at 1.5 T. Two independent and blinded readers initially characterized all masses using only the T1-weighed images (in- and opposed-phase chemical shift, unenhanced frequency-selective fat-suppressed, gadolinium-enhanced frequency-selective fat-suppressed and subtraction images) and placed each mass into one of three categories: nonsurgical, in need of follow-up, or surgical. The masses were then re-evaluated with the addition of the T2-weighted images. It was determined if the T2-weighted images changed the initial classification. Results: Forty-three of the 44 (98%) pathologically proven renal masses were characterized as a surgical mass using only the T1-weighted images. The remaining renal mass (a renal cell carcinoma) was characterized as a mass in which follow-up exams would be suggested. Thirty-eight of 38 (100%) simple renal cysts were correctly characterized using only the T1-weighted images. The T2-weighted images did not change the initial interpretation of the T1-weighted images in any of the cases. Conclusion: The results of this study suggest that T2-weighted images are not necessary in the evaluation of all renal masses and are specifically not necessary in the differentiation of solid and cystic renal neoplasms from simple renal cysts

  15. Synergetic Fe substitution and carbon connection in LiMn1−xFexPO4/C cathode materials for enhanced electrochemical performances

    International Nuclear Information System (INIS)

    Yan, Su-Yuan; Wang, Cheng-Yang; Gu, Rong-Min; Sun, Shuai; Li, Ming-Wei

    2015-01-01

    Highlights: • LiMn 0.6 Fe 0.4 PO 4 /C cathode material shows enhanced rate capability. • The Fe doped in the partial Mn sites could significantly facilitate the Li ions transfer. • The enhanced Li + ions diffusion contributes to the optimized rate capability of LiMn 0.6 Fe 0.4 PO 4 . • ACM carbonization forms well carbon coating and a 3D carbon network structure. - Abstract: To enhance the rate and cyclic performances of LiMnPO 4 cathode material for lithium-ion batteries, Mn is partially substituted with Fe, and LiMn 1−x Fe x PO 4 (x = 0.2, 0.3, 0.4, 0.5) solid solutions are synthesized and investigated. Amphiphilic carbonaceous material (ACM) forms well carbon coating and connects the LiMn 1−x Fe x PO 4 crystallites by a three-dimensional (3D) carbon network. The synergetic Fe substitution and carbon connection obviously improve the samples’ rate capacities and cyclic stability. The optimized LiMn 0.6 Fe 0.4 PO 4 /C sample delivers discharge capacities of 160 mA h g −1 at 0.05 C, 148 mA h g −1 at 1 C, and 115 mA h g −1 at 20 C. All samples have well capacity retention (>92%) after 50 charge/discharge cycles at 1 C. The enhanced electrochemical properties are mainly attributed to the improvement of Li ion and electron transport in the LiMn 1−x Fe x PO 4 /C samples, respectively mainly resulting from their modified crystal structures caused by Fe substitution and the 3D carbon coating/connection originating from ACM carbonization. LiMn 1−x Fe x PO 4 materials exhibit two discharge plateaus at ∼4.0 and ∼3.5 V (vs. Li + /Li), whose heights respectively reflect the redox potentials of Mn 3+ /Mn 2+ and Fe 3+ /Fe 2+ couples. The plateaus’ lengths correspond to the Mn/Fe ratio in LiMn 1−x Fe x PO 4 and are affected by the kinetic behavior of samples. Though the ∼4.0 V plateau shrinks with increasing discharge rate, the ∼3.5 V plateau may slightly elongate. Moreover, the Fe substituted in the partial Mn sites could significantly improve

  16. Fast T1-weighted imaging using GRASE sequence for the female pelvis

    International Nuclear Information System (INIS)

    Dohke, Masako; Watanabe, Yuji; Kumashiro, Masayuki; Amoh, Yoshiki; Ishimori, Takayoshi; Oda, Kazushige; Okumura, Akira; Koike, Shinji; Dodo, Yoshihiro

    1998-01-01

    GRASE sequence, a combination of TSE and gradient echo, has been developed as a fast T 2 -weighted imaging technique. We have modified the GRASE sequence to be used for fast T 1 -weighted imaging of the female pelvis. In this article, we compared image quality and incidence of artifacts between T 1 -weighted GRASE images and conventional T 1 -weighted SE images. In a phantom study, signal-to-noise ratio was inferior in the GRASE images relative to corresponding on SE images. Susceptibility and chemical shift artifacts seen in GRASE images were seen with almost equal incidence in SE and TSE images. In a clinical study, we compared GRASE images with SE images in six patients with endometrial cysts and four patients with dermoid cysts. The overall image quality obtained with GRASE sequence was satisfactory in all patients and was almost identical with that obtained with SE sequence. GRASE images demonstrated endometrial cysts and dermoid cysts as clearly as did SE images. T 1 -weighted GRASE imaging, however, has a relatively long TE (35 ms) for T 1 -weighted images, which makes the signal intensity of urine and uterine endometrium with long T 2 values higher than in SE images. In conclusion, GRASE sequence can be used for fast T 1 -weighted imaging of the female pelvis because of short imaging time. (author)

  17. Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T

    International Nuclear Information System (INIS)

    Wolff, Andrew B.; Pesce, Lorenzo L.; Wu, Jim S.; Smart, L.R.; Medvecky, Michael J.; Haims, Andrew H.

    2009-01-01

    At our institution, fast spin-echo (FSE) proton density (PD) imaging is used to evaluate articular cartilage, while conventional spin-echo (CSE) T1-weighted sequences have been traditionally used to characterize meniscal pathology. We sought to determine if FSE PD-weighted sequences are equivalent to CSE T1-weighted sequences in the detection of meniscal tears, obviating the need to perform both sequences. We retrospectively reviewed the records of knee arthroscopies performed by two arthroscopy-focused surgeons from an academic medical center over a 2-year period. The preoperative MRI images were interpreted independently by two fellowship-trained musculoskeletal radiologists who graded the sagittal CSE T1 and FSE PD sequences at different sittings with grades 1-5, where 1 = normal meniscus, 2 = probable normal meniscus, 3 indeterminate, 4 = probable torn meniscus, and 5 = torn meniscus. Each meniscus was divided into an anterior and posterior half, and these halves were graded separately. Operative findings provided the gold standard. Receiver operating characteristic (ROC) analysis was performed to compare the two sequences. There were 131 tears in 504 meniscal halves. Using ROC analysis, the reader 1 area under curve for FSE PD was significantly better than CSE T1 (0.939 vs. 0.902, >95% confidence). For reader 2, the difference met good criteria for statistical non-inferiority but not superiority (0.913 for FSE PD and 0.908 for CSE T1; >95% non-inferiority for difference at most of -0.027). FSE PD-weighted sequences, using our institutional protocol, are not inferior to CSE T1-weighted sequences for the detection of meniscal tears and may be superior. (orig.)

  18. Difference between T sub 1 and T sub 2 weighted MR images in avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Kokubo, Takashi; Yoshikawa, Koki; Itai, Yuzo; Iio, Masahiro; Takatori, Yoshio; Kamogawa, Morihide; Ninomiya, Setsuo [Tokyo Univ. (Japan). Faculty of Medicine

    1990-01-01

    T{sub 1} and T{sub 2} weighted MR images were compared in 32 hips with avascular necrosis, and the difference between them was discussed. In 27 of 32 hips, abnormal low intensity area in the affected femoral head is smaller in T{sub 2} weighted images than in T{sub 1} weighted images. The area of low intensity on T{sub 1} weighted image and high on T{sub 2} weighted image might be granuloma in reactive tissue and surrounding hyperemia. The difference between T{sub 1} and T{sub 2} weighted images must be taken into consideration especially in determination of the border of affected bone. (author).

  19. A Prospective Evaluation of T2-Weighted First-Pass Perfusion MR Imaging In Diagnosing Breast Neoplasms

    Institute of Scientific and Technical Information of China (English)

    XiaoJuanUu; RenyouZhai; TaoJiang; LiWang

    2004-01-01

    OBJECTIVE To compare the results from breast cancer patients who undergo T2-weighted first-pass perfusion imaging after dynamic contrast-enhanced T1-weighted imaging during the same examination,and to evaluate if T2-weighted imaging can provide additional diagnostic information over that obtained with Tl-weiahted imaaina.METHODS Twenty-nine patients with breast lesions verified by pathology (benign 12, malignant 17) underwent MR imaging with dynamic contrast-enhanced Tl-weighted imaging of the entire breasts,immediately followed by 6-sections of T2-weighted first-pass perfusion imaging of the lesions. The diagnostic indices were acquired by individual 3D Tl-weighted enhancement rate criterion and the T2 signalintensity loss rate criterion. The sensitivity and specificity were calculated and the 2 methods were compared.RESULTS With the dynamic contrast-enhanced T1-weighted imaging there was a significant differences breast lesions (t=2.563, P=0.016)overlap between the signal intensitybetween the benign and malignant However we found a considerable increase in the carcinomas and thatin the benign lesions, for a sensitivity of 94% and a specificity of 25%.With T2-weighted first-pass perfusion imaging, there was a very significant difference between the benign and malignant breast lesions(t=4.777,P<0.001), and the overlap between the signal intensity decrease in the carcinomas and that of the benign lesions on the T2-weighted images was less pronounced than the overlap in the T1-weighted images, for a sensitivity of 88% and a specificity of 75%.CONCLUSION T2-weighted first-pass perfusion imaging may help differentiate between benign and malignant breast lesions with a higher level of specificity. The combination of T1-weighted and T2-weighted imaging is feasible in a single patient examination and may improve breast MR imaging.

  20. Cerebral staging of lung cancer: is one single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence sufficient?

    Energy Technology Data Exchange (ETDEWEB)

    Ohana, Mickael; Jeung, Mi-Young; Roy, Catherine [Nouvel Hopital Civil-Hopitaux Universitaires de Strasbourg, Service de Radiologie B/Radiology Department, Strasbourg (France); Bazille, Gauthier [Clinique Saint Anne-Groupe Radiologique MIM, Strasbourg (France)

    2014-08-15

    Gadolinium-enhanced magnetic resonance imaging (MRI) is the gold standard for cerebral staging in thoracic oncology. We hypothesize that a minimalist examination, consisting of a single contrast-enhanced T1-weighted three-dimensional gradient-echo sequence (CE 3D-GRE), would be sufficient for the cerebral staging of nonsymptomatic lung cancer patients. Seventy nonsymptomatic patients (50 % men; 62 years ± 10.2) referred for cerebral staging of a lung cancer were retrospectively included. All underwent a standard 3 T MRI examination with T1, FLAIR, T2* GRE, diffusion, and CE 3D-GRE sequences, for a total examination time of 20 min. The sole CE 3D-GRE (acquisition time: 6 min) was extracted and blindly interpreted by two radiologists in search of brain metastases. Hemorrhagic features of potential lesions and relevant incidental findings were also noted. Discrepant cases were reviewed by a third reader. The full MRI examination and follow-up studies were used as a reference to calculate sensitivity and specificity of the sole CE 3D-GRE. Thirty-eight point six percent (27 out of 70) of the patients had brain metastases. Performances and reader's agreement with the sole CE 3D-GRE sequence were excellent for the diagnosis of brain metastases (sensitivity = 96.3 %, specificity = 100 %, κ = 0.91) and incidental findings (sensitivity = 85.7 %, specificity = 100 %, κ = 0.62) but insufficient for the identification of hemorrhages within the metastases (sensitivity = 33.3 %, specificity = 85.7 %, κ = 0.47). In the specific case of lung cancer, cerebral staging in nonsymptomatic patients can be efficiently achieved with a minimalistic protocol consisting of a single CE 3D-GRE sequence, completed if positive with a T2* sequence for hemorrhagic assessment, thus halving appointment delays. (orig.)

  1. Contrast-enhanced MR imaging of metastatic brain tumor at 3 Tesla. Utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence

    International Nuclear Information System (INIS)

    Komada, Tomohiro; Naganawa, Shinji; Ogawa, Hiroshi

    2008-01-01

    We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T 1 -weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T 1 -weighted spin echo (2D-SE) imaging at 3 T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P 1 -weighted imaging. (author)

  2. Characterization of pH dependent Mn(II) oxidation strategies and formation of a bixbyite-like phase by Mesorhizobium australicum T-G1

    Science.gov (United States)

    Bohu, Tsing; Santelli, Cara M; Akob, Denise M.; Neu, Thomas R; Ciobota, Valerian; Rösch, Petra; Popp, Jürgen; Nietzsche, Sándor; Küsel, Kirsten

    2015-01-01

    Despite the ubiquity of Mn oxides in natural environments, there are only a few observations of biological Mn(II) oxidation at pH MOB) isolates limits our understanding of how pH influences biological Mn(II) oxidation in extreme environments. Here, we report that a novel MOB isolate, Mesorhizobium australicum strain T-G1, isolated from an acidic and metalliferous uranium mining area, can oxidize Mn(II) at both acidic and neutral pH using different enzymatic pathways. X-ray diffraction, Raman spectroscopy, and scanning electron microscopy with energy dispersive X-ray spectroscopy revealed that T-G1 initiated bixbyite-like Mn oxide formation at pH 5.5 which coincided with multi-copper oxidase expression from early exponential phase to late stationary phase. In contrast, reactive oxygen species (ROS), particularly superoxide, appeared to be more important for T-G1 mediated Mn(II) oxidation at neutral pH. ROS was produced in parallel with the occurrence of Mn(II) oxidation at pH 7.2 from early stationary phase. Solid phase Mn oxides did not precipitate, which is consistent with the presence of a high amount of H2O2 and lower activity of catalase in the liquid culture at pH 7.2. Our results show that M. australicum T-G1, an acid tolerant MOB, can initiate Mn(II) oxidation by varying its oxidation mechanisms depending on the pH and may play an important role in low pH manganese biogeochemical cycling.

  3. Influence of elemental diffusion on low temperature formation of MgH2 in TiMn1.3T0.2-Mg (T = 3d-transition elements)

    International Nuclear Information System (INIS)

    Yamamoto, K.; Tanioka, S.; Tsushio, Y.; Shimizu, T.; Morishita, T.; Orimo, S.; Fujii, H.

    1996-01-01

    In order to examine the influence of the elemental diffusion from the host compound into the Mg region on low temperature formation of MgH 2 , we have investigated the hydriding properties and the microstructures of the composite materials TiMn 1.3 T 0.2 -Mg (T = V, Cr, Mn, Fe, Co, Ni and Cu). MgH 2 is formed at 353 K in all composite materials. Of all the substitutions, the amount of MgH 2 is the largest in the case of the Cu substitution, which originates from the existence of the Mg-Mg 2 Cu eutectic formed by Cu diffusion from the host compound TiMn 1.3 Cu 0.2 into the Mg region during the liquid phase sintering. In addition, the hydrogen capacity of TiMn 1.3 Cu 0.2 -Mg (that is TiMn 1.3 Cu 0.1 -(Mg+Mg 2 Cu) after the sintering) easily saturates in comparison with TiMn 1.5 -(Mg+Mg 2 Cu) without Cu diffusion. It is concluded that Cu diffusion promotes the mobility of hydrogen atoms at the complex interface between the host compound and the Mg region. (orig.)

  4. Characterization of pH dependent Mn(II) oxidation strategies and formation of a bixbyite-like phase by Mesorhizobium australicum T-G1

    Science.gov (United States)

    Bohu, Tsing; Santelli, Cara M; Akob, Denise M.; Neu, Thomas R; Ciobota, Valerian; Rösch, Petra; Popp, Jürgen; Nietzsche, Sándor; Küsel, Kirsten

    2015-01-01

    Despite the ubiquity of Mn oxides in natural environments, there are only a few observations of biological Mn(II) oxidation at pH < 6. The lack of low pH Mn-oxidizing bacteria (MOB) isolates limits our understanding of how pH influences biological Mn(II) oxidation in extreme environments. Here, we report that a novel MOB isolate, Mesorhizobium australicum strain T-G1, isolated from an acidic and metalliferous uranium mining area, can oxidize Mn(II) at both acidic and neutral pH using different enzymatic pathways. X-ray diffraction, Raman spectroscopy, and scanning electron microscopy with energy dispersive X-ray spectroscopy revealed that T-G1 initiated bixbyite-like Mn oxide formation at pH 5.5 which coincided with multi-copper oxidase expression from early exponential phase to late stationary phase. In contrast, reactive oxygen species (ROS), particularly superoxide, appeared to be more important for T-G1 mediated Mn(II) oxidation at neutral pH. ROS was produced in parallel with the occurrence of Mn(II) oxidation at pH 7.2 from early stationary phase. Solid phase Mn oxides did not precipitate, which is consistent with the presence of a high amount of H2O2 and lower activity of catalase in the liquid culture at pH 7.2. Our results show that M. australicum T-G1, an acid tolerant MOB, can initiate Mn(II) oxidation by varying its oxidation mechanisms depending on the pH and may play an important role in low pH manganese biogeochemical cycling.

  5. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo

    2017-01-01

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory

  6. Assessment of arterial wall enhancement for differentiation of parent artery disease from small artery disease: Comparison between histogram analysis and visual analysis on 3 dimensional contrast-enhanced T1-weighted turbo spin echo MR images at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Kim, Tae Won; Hwang, Eo Jin; Choi, Hyun Seok; Koo, Ja Seung; Shin, Yong Sam; Jung, So Lyung; Ahn, Kook Jin; Kim, Bum Soo [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-04-15

    The purpose of this study was to compare the histogram analysis and visual scores in 3T MRI assessment of middle cerebral arterial wall enhancement in patients with acute stroke, for the differentiation of parent artery disease (PAD) from small artery disease (SAD). Among the 82 consecutive patients in a tertiary hospital for one year, 25 patients with acute infarcts in middle cerebral artery (MCA) territory were included in this study including 15 patients with PAD and 10 patients with SAD. Three-dimensional contrast-enhanced T1-weighted turbo spin echo MR images with black-blood preparation at 3T were analyzed both qualitatively and quantitatively. The degree of MCA stenosis, and visual and histogram assessments on MCA wall enhancement were evaluated. A statistical analysis was performed to compare diagnostic accuracy between qualitative and quantitative metrics. The degree of stenosis, visual enhancement score, geometric mean (GM), and the 90th percentile (90P) value from the histogram analysis were significantly higher in PAD than in SAD (p = 0.006 for stenosis, < 0.001 for others). The receiver operating characteristic curve area of GM and 90P were 1 (95% confidence interval [CI], 0.86-1.00). A histogram analysis of a relevant arterial wall enhancement allows differentiation between PAD and SAD in patients with acute stroke within the MCA territory.

  7. Evaluation of neonatal brain myelination using the T1- and T2-weighted MRI ratio.

    Science.gov (United States)

    Soun, Jennifer E; Liu, Michael Z; Cauley, Keith A; Grinband, Jack

    2017-09-01

    To validate the T1- and T2-weighted (T1w/T2w) MRI ratio technique in evaluating myelin in the neonatal brain. T1w and T2w MR images of 10 term neonates with normal-appearing brain parenchyma were obtained from a single 1.5 Tesla MRI and retrospectively analyzed. T1w/T2w ratio images were created with a postprocessing pipeline and qualitatively compared with standard clinical sequences (T1w, T2w, and apparent diffusion coefficient [ADC]). Quantitative assessment was also performed to assess the ratio technique in detecting areas of known myelination (e.g., posterior limb of the internal capsule) and very low myelination (e.g., optic radiations) using linear regression analysis and the Michelson Contrast equation, a measure of luminance contrast intensity. The ratio image provided qualitative improvements in the ability to visualize regional variation in myelin content of neonates. Linear regression analysis demonstrated a significant inverse relationship between the ratio intensity values and ADC values in the posterior limb of the internal capsule and the optic radiations (R 2  = 0.96 and P ratio images were 1.6 times higher than T1w, 2.6 times higher than T2w, and 1.8 times higher than ADC (all P ratio improved visualization of the corticospinal tract, one of the earliest myelinated pathways. The T1w/T2w ratio accentuates contrast between myelinated and less myelinated structures and may enhance our diagnostic ability to detect myelination patterns in the neonatal brain. 2 Technical Efficacy: Stage2 J. MAGN. RESON. IMAGING 2017;46:690-696. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Spot Sign in Acute Intracerebral Hemorrhage in Dynamic T1-Weighted Magnetic Resonance Imaging.

    Science.gov (United States)

    Schindlbeck, Katharina A; Santaella, Anna; Galinovic, Ivana; Krause, Thomas; Rocco, Andrea; Nolte, Christian H; Villringer, Kersten; Fiebach, Jochen B

    2016-02-01

    In computed tomographic imaging of acute intracerebral hemorrhage spot sign on computed tomographic angiography has been established as a marker for hematoma expansion and poor clinical outcome. Although, magnetic resonance imaging (MRI) can accurately visualize acute intracerebral hemorrhage, a corresponding MRI marker is lacking to date. We prospectively examined 50 consecutive patients with acute intracerebral hemorrhage within 24 hours of symptom onset. The MRI protocol consisted of a standard stroke protocol and dynamic contrast-enhanced T1-weighted imaging with a time resolution of 7.07 s/batch. Stroke scores were assessed at admission and at time of discharge. Volume measurements of hematoma size and spot sign were performed with MRIcron. Contrast extravasation within sites of the hemorrhage (MRI spot sign) was seen in 46% of the patients. Patients with an MRI spot sign had a significantly shorter time to imaging than those without (Pspot sign compared with those without (P≤0.001). Hematoma expansion was observed in the spot sign group compared with the nonspot sign group, although the differences were not significant. Spot sign can be detected using MRI on postcontrast T1-weighted and dynamic T1-weighted images. It is associated with worse clinical outcome. The time course of contrast extravasation in dynamic T1 images indicates that these spots represent ongoing bleeding. © 2015 American Heart Association, Inc.

  9. Characterization of pH dependent Mn(II oxidation strategies and formation of a bixbyite-like phase by Mesorhizobium australicum T-G1

    Directory of Open Access Journals (Sweden)

    Tsing eBohu

    2015-07-01

    Full Text Available Despite the ubiquity of Mn oxides in natural environments, there are only a few observations of biological Mn(II oxidation at pH < 6. The lack of low pH Mn-oxidizing bacteria (MOB isolates limits our understanding of how pH influences biological Mn(II oxidation in extreme environments. Here, we report that a novel MOB isolate, Mesorhizobium australicum strain T-G1, isolated from an acidic and metalliferous uranium mining area, can oxidize Mn(II at both acidic and neutral pH using different enzymatic pathways. X-ray diffraction (XRD, Raman spectroscopy, and scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS revealed that T-G1 initiated bixbyite-like Mn oxide formation at pH 5.5 which coincided with multi-copper oxidase (MCO expression from early exponential phase to late stationary phase. In contrast, reactive oxygen species (ROS, particularly superoxide, appeared to be more important for T-G1 mediated Mn(II oxidation at neutral pH. ROS was produced in parallel with the occurrence of Mn(II oxidation at pH 7.2 from early stationary phase. Solid phase Mn oxides did not precipitate, which is consistent with the presence of a high amount of H2O2 and lower activity of catalase in the liquid culture at pH 7.2. Our results show that M. australicum T-G1, an acid tolerant MOB, can initiate Mn(II oxidation by varying its oxidation mechanisms depending on the pH and may play an important role in low pH manganese biogeochemical cycling.

  10. Enhanced magnetoresistance and Griffiths phase induced by Mo substitution in La0.7Ca0.15Sr0.15Mn1-xMoxO3 (0 ≤ x ≤ 0.05)

    International Nuclear Information System (INIS)

    Narsinga Rao, G; Chen, J W; Neeleshwar, S; Chen, Y Y; Wu, M K

    2009-01-01

    Structural, magnetic and electrical properties of the La 0.7 Ca 0.15 Sr 0.15 Mn 1-x Mo x O 3 (0 ≤ x ≤ 0.05) compounds have been investigated. Powder x-ray analysis reveals that the sample with x = 0 crystallizes in the rhombohedral (R 3-bar c) structure, whereas in the Mo doped samples the structure can be indexed by an orthorhombic (Pbnm) structure. The important observations of the magnetic and transport properties are: (i) the Mo substitution induces a distinct suppression of the metal-insulator (T MI ) and ferromagnetic (FM)-paramagnetic transition (T C ) and the temperature of T MI was found to be higher than T C in the Mo-doped samples, (ii) the substitution of Mo enhances the magnetoresistance at room temperature, (iii) a large deviation from the Curie-Weiss law well above T C in the Mo substituted samples indicates the existence of a Griffiths phase and (iv) long-range FM order persists in all samples with a linear decrease of saturation moment as x increases. These results are discussed in terms of the Mn-site disorder and opening of strong FM coupling between Mn 2+ -O-Mn 3+ , due to the Mn 2+ ions induced by Mo 6+ at the expense of Mn 4+ ions in the La 0.7 Ca 0.15 Sr 0.15 Mn 1-x Mo x O 3 system.

  11. Mn-substituted perovskites RECoxMn1-xO3: a comparison between magnetic properties of LaCoxMn1-xO3 and GdCoxMn1-xO3

    Directory of Open Access Journals (Sweden)

    Barahona, P.

    2008-08-01

    Full Text Available Cooperative phenomena constitute important mechanisms to explain the magnetic properties of the perovskite manganites REMnO3, in which the rare-earth and/or Mn is partially replaced by divalent elements. In this way, the manganese ion changes its valence state (Mn3+ Mn4+, triggering strong magnetic interactions. In this work we describe the case of GdCoxMn1-xO3 (0.0 ≤ x ≤ 1.0 for which the antiferromagnetic interaction between the Gd sublattice and the Mn/Co network leads to a reversal of the magnetic moment at low temperature. No inversion is observed for the LaCoxMn1-xO3 series, in which the ordering temperature may attain a maximum of 235 K for LaCo0.50Mn0.50O3, while it is only 120 K for similar Co/Mn ratio in the case of GdCo0.50Mn0.50O3. Magnetic properties are described in terms of two regimes: one, for x 3 manganite and another one, for x > 0.5, when Mn substitutes Co in the GdCoO3 cobaltite, while the magnetic interactions are maximized at x(Co = 0.50. This hypothesis is discussed in terms of the respective oxidation states of both manganese (Mn3+ / Mn4+ and cobalt (Co2+ / Co3+.El fenómeno cooperativo constituye un importante mecanismo para explicar las propiedades magnéticas de las perovskitas manganitas TRMnO3, en las que el catión de tierra rara, TR, y/o el catión Mn3+ son parcialmente reemplazados por cationes divalentes. Por esta vía el ión de manganeso cambia de estado de valencia (Mn3+ Mn4+, generando fuertes interacciones magnéticas. En el presente trabajo se describe el caso de las soluciones sólidas GdCoxMn1-xO3 (0.0 ≤ x ≤ 1.0 para las que la interacción antiferromagnética entre la subred del Gd3+ y la red Mn/Co lleva a una inversión del momento magnético a baja temperatura. No se ha observado inversión para la serie LaCoxMn1-xO3, en que la temperatura de orden puede alcanzar un máximo de 235K para LaCo0.50Mn0.50O3, mientras que en el caso de GdCo0.50Mn0.50O3, en que sí se observa inversión, la

  12. Using graphene nanosheets as a conductive additive to enhance the capacitive performance of α-MnO2

    International Nuclear Information System (INIS)

    Jiang, Rongyan; Cui, Congying; Ma, Houyi

    2013-01-01

    Graphene nanosheets (GNs) were directly used as a type of novel but powerful planar conductive additive in the α-MnO 2 -based electrode material for electrochemical capacitors (ECs), to improve the low electronic conductivity of α-MnO 2 . It was found that the specific capacitance (SC) and cycling performance of α-MnO 2 were obviously enhanced when GNs co-existed with acetylene black (AB), a conventional carbon-based conductive agent, at an appropriate weight ratio in the electrode material (GNs and AB were 10 wt% and 5 wt% of total weight, respectively). The unusual phenomenon was attributed to the following two reasons: (i) the planar graphene conductive additive could bridge active α-MnO 2 particles more effectively via a “plane-to-point” conducting mode and (ii) AB particles might serve as the fillings in the electrode material and connect the isolated α-MnO 2 particles to GNs through a “filling effect”, thereby constructing a novel and more effective conducting network. In this way, the synergy effect between the “plane-to-point” mode (due to GNs) and the “filling” mode (due to AB) significantly decreased the charge-transfer resistance of the α-MnO 2 -based electrode. With much faster charge-transfer process, the capacitive performance of α-MnO 2 was greatly enhanced. On the contrary, when GNs were excess, the effective conducting network was weakened by the agglomeration of GNs and the absence of AB, leading to a lower conductivity and non-enhanced capacitive performance of α-MnO 2

  13. T1 Gd-enhanced compared with CISS sequences in retinoblastoma: superiority of T1 sequences in evaluation of tumour extension

    Energy Technology Data Exchange (ETDEWEB)

    Gizewski, Elke R.; Wanke, Isabel; Guengoer, Ali-Riza; Forsting, Michael [University Hospital, Department of Diagnostic and Interventional Neuroradiology, Essen (Germany); Jurklies, Christine [University Hospital Essen, Department of Ophthalmology (Germany)

    2005-01-01

    Background As adequate therapy for retinoblastoma in young children depends on infiltration of extra-retinal structures, diagnostic modalities play an essential role. Methods: In this widely extended study, 80 children with retinoblastoma were studied with MRI (standard fat-suppressed Gd-enhanced T1, T2 thin-slice sequences (additionally with small loop surface coil), constructive interference in steady state (CISS) sequence covering the orbita). The images were analysed by two blinded neuroradiologists. Histology was used as the gold standard. MRI assumed infiltration of extra-retinal structures in 13 of 80 patients of which ten were confirmed by histology. Affected extra-retinal structures were: optic nerve (five, of which two were on CISS and three on T1 with higher image resolution using the surface coil), scleral infiltration (five, of which four on CISS and T1) and ciliary body infiltration (one on CISS and T1). Another 61 enucleated patients did not have any extra-retinal infiltration in histology. The CISS sequence with multiplanar reconstruction was mainly helpful in revealing exact three-dimensional tumour extension with excellent clinical acceptance and pre-surgical planning but T1 fat-suppressed Gd-enhanced images were superior in revealing exact tumour extension. CISS sequences allow to produce excellent anatomical images and to perform multiplanar reconstruction to better demonstrate tumour extension. However, T1-weighted sequences after contrast application are more sensitive (60 versus 40%) in detecting infiltration of the optic nerve but equal in detecting scleral infiltration. (orig.)

  14. Measurement of brain oxygenation changes using dynamic T1-weighted imaging

    DEFF Research Database (Denmark)

    Haddock, Bryan; Larsson, Henrik B W; Hansen, Adam E

    2013-01-01

    Magnetic resonance imaging (MRI) has proven useful in evaluating oxygenation in several types of tissue and blood. This study evaluates brain tissue oxygenation changes between normoxia and hyperoxia in healthy subjects using dynamic T1 and T2*-weighted imaging sequences. The change in FiO2 induced...... by hyperoxia caused a significant decrease in T1. A model to determine changes in tissue oxygen tension from the T1-weighted MRI signal is presented based on previous findings that T1 is sensitive to oxygen tension whereas T2* is sensitive to blood saturation. The two sequences produce results with different...... regional and temporal dynamics. These differences combined with results from simulations of the T1 signal intensities, indicate an increase in extravascular oxygen tension during hyperoxia. This study concludes that T1 and T2* responses to FiO2 serve as independent biomarkers of oxygen physiology...

  15. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar [SGRR Institute of Medical and Health Sciences, Patel Nagar, Dehradun (India)

    2017-11-15

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol.

  16. Qualitative and quantitative comparison of contrast-enhanced fluid-attenuated inversion recovery, magnetization transfer spin echo, and fat-saturation T1-weighted sequences in infectious meningitis

    International Nuclear Information System (INIS)

    Azad, Rajiv; Tayal, Mohit; Azad, Sheenam; Sharma, Garima; Srivastava, Rajendra Kumar

    2017-01-01

    To compare the contrast-enhanced fluid-attenuated inversion recovery (CE-FLAIR), the CE T1-weighted (CE-T1W) sequence with fat suppression (FS) and magnetization transfer (MT) for early detection and characterization of infectious meningitis. Fifty patients and 10 control subjects were evaluated with the CE-FLAIR and the CE-T1W sequences with FS and MT. Qualitative assessment was done by two observers for presence and grading of abnormal leptomeningeal enhancement. Quantitative assessment included computation of net meningeal enhancement, using single pixel signal intensity software. A newly devised FLAIR based scoring system, based on certain imaging features including ventricular dilatation, ependymal enhancement, infarcts and subdural effusions was used to indicate the etiology. Data were analysed using the Student's t test, Cohen's Kappa coefficient, Pearson's correlation coefficient, the intraclass correlation coefficient, one way analysis of variance, and Fisher's exact test with Bonferroni correction as the post hoc test. The CE-FLAIR sequence demonstrated a better sensitivity (100%), diagnostic accuracy (95%), and a stronger correlation with the cerebrospinal fluid, total leukocyte count (r = 0.75), protein (r = 0.77), adenosine deaminase (r = 0.81) and blood glucose (r = -0.6) values compared to the CE-T1W sequences. Qualitative grades and quantitative meningeal enhancement on the CE-FLAIR sequence were also significantly greater than those on the other sequences. The FLAIR based scoring system yielded a diagnostic accuracy of 91.6% and a sensitivity of 96%. A strong inverse Pearson's correlation (r = -0.95) was found between the assigned score and patient's Glasgow Coma Scale at the time of admission. The CE-FLAIR sequence is better suited for evaluating infectious meningitis and could be included as a part of the routine MR imaging protocol

  17. Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering

    International Nuclear Information System (INIS)

    Biederer, J.; Reuter, M.; Both, M.; Grimm, J.; Heller, M.; Muhle, C.; Graessner, J.

    2002-01-01

    The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2-weighted TSE. (orig.)

  18. T2-weighted vs. intrathecal contrast-enhanced MR cisternography in the evaluation of CSF rhinorrhea

    International Nuclear Information System (INIS)

    Ecin, Gaye; Oner, A. Yusuf; Tokgoz, Nil; Ucar, Murat; Tali, Turgut; Aykol, Sukru

    2013-01-01

    Background: Endoscopic surgical approach is being more widely used in the treatment of cerebrospinal fluid (CSF) rhinorrhea. Accurate localization of CSF fistulas prior to surgery is essential in increasing the success of dural repair and in decreasing negative or recurrent explorations. Purpose: To evaluate and compare intrathecal contrast medium-enhanced magnetic resonance cisternography (CEMRC) with T2-weighted MR cisternography (T2MRC) in identifying the presence and site of CSF rhinorrhea. Material and Methods: Sixty patients with suspected CSF rhinorrhea underwent MR cisternography including intrathecally enhanced fat-suppressed T1WI in three orthogonal planes and T2WI in the coronal plane. Both set of images were reviewed by two blinded radiologists for the presence and location of CSF leakage. Imaging data were compared with surgical findings and/or beta-2 transferrin testing. Results: With surgery proven CSF leakage in 20 instances as reference, CEMRC detected 18 (90%), whereas T2MRC reported only 13 (65%) correctly. Overall, sensitivity, specificity, positive predictive value, and negative predictive value in detecting CSF fistulas were 92%, 80%, 76%, and 93% for CEMRC, and 56%, 77%, 64%, and 71% for T2MRC, respectively. Conclusion: The minimally invasive CEMRC is an effective method with higher sensitivity and specificity than T2MRC in the evaluation of CSF fistulas

  19. Added diagnostic value of T2-weighted MR imaging to gadolinium-enhanced three-dimensional dynamic MR imaging for the detection of small hepatocellular carcinomas

    International Nuclear Information System (INIS)

    Kim, Young Kon; Lee, Young Hwan; Kim, Chong Soo; Han, Young Min

    2008-01-01

    Purpose: To assess the added value of T2-weighted MRI to gadolinium-enhanced dynamic MRI for detection of HCCs. Materials and methods: Two readers retrospectively analyzed MRIs of 115 patients with 131 HCCs (size; 0.6-2.0 cm) that had been diagnosed by histology (n = 41) or imaging findings (n = 90). Two separate blind image analyses of the gadolinium set and the combined T2-weighted imaging and gadolinium sets were performed. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method with four-point scale. Sensitivity and positive predictive value were also calculated. Results: For both observers, the Az values and sensitivities with the combined T2-weighed imaging and gadolinium set (mean Az 0.806, sensitivity 84.7) were significantly higher than those with the gadolinium set (mean Az 0.660, sensitivity 59.9) (p < 0.05). The addition of T2-weighted imaging led to a change in diagnosis for 27 lesions by both observers, which at gadolinium set were assigned a confidence level of 1 or 2 but at additional reading of T2-weighted imaging were assigned a confidence level of 3 or 4. For the positive predictive values, each image set showed a similar value for each observer. Conclusion: The addition of T2-weighted imaging to gadolinium-enhanced 3D dynamic imaging could be helpful in the detection of HCC by increasing reader confidence for HCCs with equivocal findings on gadolinium-enhanced MRIs

  20. MR mammography for diagnosis of breast cancer. Evaluation of usefulness of contrast-enhanced fat-suppressed T1 weight image

    International Nuclear Information System (INIS)

    Kusama, Ritsu; Takayama, Fumiyoshi; Tsuchiya, Shin-ichi

    2005-01-01

    We assessed the value of contrast-enhanced fat-suppressed T1 weight images (CFT1) in diagnosing breast cancers showing mass-like lesions in MR imaging. MR imaging demonstrated 41 carcinoma and 15 fibroadenoma cases. We classified these into 3 groups based on the status of the border and the adjacent zone in CFT1: a well-defined border, an ill-defined border, and linear high signal intensity in the adjacent zone. In carcinoma cases, 23 showed well-defined borders and 18 showed linear high signal intensity in adjacent zone. In fibroadenoma cases, 14 cases revealed well-defined borders and one case an ill-defined border. We compared the borders and adjacent zones of tumors in CFT1 with the pathological findings. Cases of fibroadenoma with well-defined borders in CFT1 showed well-circumscribed nodules with no infiltration of surrounding lymphocytes and fibroblast Cases of carcinoma with ill-defined borders showed infiltration by tumor cells to adjacent tissue without lymphocytes. Cases of carcinoma with linear high signal intensity in the adjacent zone revealed infiltration of the lymph cells and fibroblasts cells in the adjacent zone. The linear high signal intensity was distinguishable from the peripheral enhancement in dynamic MR images. We conclude that the borders and adjacent zones of tumors in CFT1 are useful for diagnosis. (authors)

  1. Enhancement of abdominal structures on MRI at 1.5 and 3 T: a retrospective intraindividual crossover comparison

    Energy Technology Data Exchange (ETDEWEB)

    AlObaidy, Mamdoh [King Faisal Specialist Hospital and Research Center, Department of Radiology, Riyadh (Saudi Arabia); University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States); Ramalho, Miguel; Velloni, Fernanda; Matos, Antonio P.; Herman, Kevin; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2017-04-15

    To quantitatively compare the extent of enhancement of abdominal structures on MRI in an intraindividual fashion at 1.5 and 3 T. HIPAA-compliant, retrospective, longitudinal, intraindividual, crossover study, with waived informed consent, of consecutive individuals scanned at both 1.5 and 3 T closed-bore magnets using gadobenate dimeglumine during different phases of enhancement at tightly controlled arterial phase timing. Quantitative ROI measurements and qualitative sub-phase arterial phase assignments were independently performed by two radiologists. Qualitative discrepancies were resolved by a senior radiologist. Final population included 60 patients [41 female and 19 male; age, 49.35 ± 18.31 years (range 16-81); weight, 78.88 ± 20.3 kg (range 44.5-136)]. Similar enhancement peak patterns were noted at both field strengths. Interobserver agreement of quantitative evaluations was substantial. Significantly higher amplitudes of enhancement peaks were noted for all abdominal solid organs during all phases at 3 T, except for the pancreas (p = 0.17-0.30). Significantly higher amplitudes of enhancement peaks of the abdominal aorta at 1.5 T were noted. Similar peak patterns of enhancement for abdominal structures were observed at 1.5 and 3 T, with solid abdominal organs showing a higher percentage enhancement at 3 T, while unexpectedly higher aortic higher percentage enhancement was observed at 1.5 T. (orig.)

  2. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  3. Assessment of T2-Weighted Coronal Magnetic Resonance Images in the Investigation of Pituitary Lesions

    International Nuclear Information System (INIS)

    Yuksekkaya, Ruken; Aggunlu, Levent; Oner, Yusuf; Celik, Halil; Akpek, Sergin; Celikyay, Fatih

    2014-01-01

    Magnetic resonance imaging is the most important diagnostic method in the investigation of the pituitary lesions. Our aim is to determine whether T2-weighted coronal images may be helpful in the evaluation of the pituitary gland with suspected pituitary adenomas. One hundred and sixty-seven patients were examined prospectively with T2-weighted coronal and T1-weighted coronal images enhanced with intravenous contrast material. The images were evaluated for the presence, the size, the location, and the ancillary signs including sellar floor erosion or ballooning, infindibulary deviation, convexity of the superior border of the gland, diffuse enlargement of the gland, and the invasion of the cavenous sinuses on both images. In forty-six (28%) patients lesions were revealed on both sequences. In twenty-one (12%) patients the lesions that were revealed on the T1-weighted images were not detected on the T2-weighted images. Positive predictive value, negative predictive value, sensitivity, specificity, and diagnostic accuracy rates of T2-weighted coronal images on the detection of the presence of lesions were 100%, 17.4%, 68.7%, 100%, and 87.4%, respectively. Both T2-weighted coronal and T1-weighted coronal images enhanced with intravenous gadolinium-based contrast material are important in the diagnosis of pituitary adenomas. T2-weighted coronal images could be used as a screening tool for the primary evaluation of the pituitary gland

  4. Enhanced electrochemical performance of LiMn2O4 by constructing a stable Mn2+-rich interface

    Science.gov (United States)

    Lu, Zhongpei; Lu, Xiaojun; Ding, Jingjing; Zhou, Ting; Ge, Tao; Yang, Gang; Yin, Fan; Wu, Mingfang

    2017-12-01

    Spinel LiMn2O4 has drawn continuous attentions due to its low cost, good electrochemical performance, environmental friendliness and natural abundant resources. In view of its severe capacity fading, some types of manganese-based compounds with different Mn oxidation states are selected to protect bare LiMn2O4 by constructing a stable coating layer. In this work, LiMn2O4@LiMnPO4 composite, spherical LiMn2O4 (LMO) as core and Mn2+-rich phase of LiMnPO4 (LMP) as shell, is designed and synthesized. Two composites of LiMn2O4 particles coated with 3 wt% and 10 wt% LiMnPO4 have been compared studied. After 100 cycles at 0.5C rate, the two samples deliver capacity retentions of 96.63% and 93.23% of their initial capacities. Moreover, LMO coated by 3 wt% LiMnPO4 delivers 100.3 mAh g-1 after 200 cycles at 10C rate and 76.3 mAh g-1 after 1000 cycles at 20C rate, much higher than bare LiMn2O4 with 90 mAh g-1 and 45.8 mAh g-1, respectively. This core-shell structure with Mn2+-rich phase as a coating layer effectively enhance the material's cycling performance and rate capacity by reducing the contact of LiMn2O4 with electrolyte.

  5. High-intensity facial nerve lesions on T2-weighted images in chronic persistent facial nerve palsy

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Dept. of Radiology, Tottori Univ. (Japan); Ishii, K. [Dept. of Radiology, Sendai City Hospital, Sendai (Japan); Okitsu, T. [Dept. of Otolaryngology, Sendai City Hospital (Japan); Ogawa, T. [Dept. of Radiology, Tottori Univ. (Japan); Okudera, T. [Dept. of Radiology, Research Inst. of Brain and Blood Vessels-Akita, Akita (Japan)

    2001-05-01

    Our aim was to estimate the value of MRI in detecting irreversibly paralysed facial nerves. We examined 95 consecutive patients with a facial nerve palsy (14 with a persistent palsy, and 81 with good recovery), using a 1.0 T unit, with T2-weighted and contrast-enhanced T1-weighted images. The geniculate ganglion and tympanic segment had gave high signal on T2-weighted images in the chronic stage of persistent palsy, but not in acute palsy. The enhancement pattern of the facial nerve in the chronic persistent facial nerve palsy is similar to that in the acute palsy with good recovery. These findings suggest that T2-weighted MRI can be used to show severely damaged facial nerves. (orig.)

  6. Diagnostic value of brain chronic black holes on T1-weighted MR images in clinically isolated syndromes.

    Science.gov (United States)

    Mitjana, Raquel; Tintoré, Mar; Rocca, Maria A; Auger, Cristina; Barkhof, Frederik; Filippi, Massimo; Polman, Chris; Fazekas, Franz; Huerga, Elena; Montalban, Xavier; Rovira, Alex

    2014-10-01

    Non-enhancing black holes (neBHs) are more common in multiple sclerosis (MS) patients with longer disease durations and progressive disease subtypes. Our aim was to analyse the added value of neBHs in patients with clinically isolated syndromes (CISs) for predicting conversion to clinically definite MS (CDMS). Patients were classified based on the presence or absence of neBHs and on the number of Barkhof-Tintoré (B-T) criteria fulfilled. Dissemination in space (DIS) was defined as the presence of at least three of the four B-T criteria. Dissemination in time (DIT)1 was defined by simultaneous presence of enhancing and non-enhancing lesions. DIT2 was defined by simultaneous presence of neBHs and T2 lesions not apparent on T1-weighted images. Focal T2-hyperintense brain lesions were identified in 87.7% of the 520 CIS patients, and 41.4% of them presented at least one neBH. Patients meeting DIS, DIT1, and DIT2 had a significantly higher rate of conversion to CDMS. After adjusting for DIS, only patients who fulfilled DIT1 preserved a significant increase in CDMS conversion. Non-enhancing black holes in CIS patients are associated with a higher risk of conversion to CDMS. However, the predictive value of this finding is lost when added to the DIS criteria. © The Author(s) 2014.

  7. Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    Science.gov (United States)

    Clavijo Jordan, M Veronica; Beeman, Scott C; Baldelomar, Edwin J; Bennett, Kevin M

    2014-01-01

    Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have limited in vivo detection due to a number of constraints with T2 or T2*-weighted imaging. T1-weighted imaging is often preferred for molecular MRI, but most T1-shortening agents are small chelates with low metal payload or are nanoparticles that also shorten T2 and limit the range of concentrations detectable with T1-weighting. Here we used tungsten and iron deposition to form doped iron oxide crystals inside the apoferritin cavity to form a WFe nanoparticle with a disordered crystal and un-coupled atomic magnetic moments. The atomic magnetic moments were thus localized, resulting in a principally paramagnetic nanoparticle. The WFe nanoparticles had no coercivity or saturation magnetization at 5 K and sweeping up to ± 20,000 Oe, while native ferritin had a coercivity of 3000 Oe and saturation at ± 20,000 Oe. This tungsten-iron crystal paramagnetism resulted in an increased WFe particle longitudinal relaxivity (r1) of 4870 mm(-1) s(-1) and a reduced transverse relaxivity (r2) of 9076 mm(-1) s(-1) compared with native ferritin. The accumulation of the particles was detected with T1-weighted MRI in concentrations from 20 to 400 nm in vivo, both injected in the rat brain and targeted to the rat kidney glomerulus. The WFe apoferritin nanoparticles were not cytotoxic up to 700 nm particle concentrations, making them potentially important for targeted molecular MRI. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA-enhanced

  9. Detection of Local Tumor Recurrence After Definitive Treatment of Head and Neck Squamous Cell Carcinoma: Histogram Analysis of Dynamic Contrast-Enhanced T1-Weighted Perfusion MRI.

    Science.gov (United States)

    Choi, Sang Hyun; Lee, Jeong Hyun; Choi, Young Jun; Park, Ji Eun; Sung, Yu Sub; Kim, Namkug; Baek, Jung Hwan

    2017-01-01

    This study aimed to explore the added value of histogram analysis of the ratio of initial to final 90-second time-signal intensity AUC (AUCR) for differentiating local tumor recurrence from contrast-enhancing scar on follow-up dynamic contrast-enhanced T1-weighted perfusion MRI of patients treated for head and neck squamous cell carcinoma (HNSCC). AUCR histogram parameters were assessed among tumor recurrence (n = 19) and contrast-enhancing scar (n = 27) at primary sites and compared using the t test. ROC analysis was used to determine the best differentiating parameters. The added value of AUCR histogram parameters was assessed when they were added to inconclusive conventional MRI results. Histogram analysis showed statistically significant differences in the 50th, 75th, and 90th percentiles of the AUCR values between the two groups (p Histogram analysis of AUCR can improve the diagnostic yield for local tumor recurrence during surveillance after treatment for HNSCC.

  10. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    Energy Technology Data Exchange (ETDEWEB)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Espinosa, Norman [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland)

    2017-08-15

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  11. Is there an added value of T1-weighted contrast-enhanced fat-suppressed spin-echo MR sequences compared to STIR sequences in MRI of the foot and ankle?

    International Nuclear Information System (INIS)

    Zubler, Veronika; Zanetti, Marco; Dietrich, Tobias J.; Pfirrmann, Christian W.; Mamisch-Saupe, Nadja; Espinosa, Norman

    2017-01-01

    To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. (orig.)

  12. Synergetic Fe substitution and carbon connection in LiMn{sub 1−x}Fe{sub x}PO{sub 4}/C cathode materials for enhanced electrochemical performances

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Su-Yuan; Wang, Cheng-Yang [Key Laboratory for Green Chemical Technology of Ministry of Education, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072 (China); Collaborative Innovation Center of Chemical Science and Engineer (Tianjin), Tianjin University, Tianjin 300072 (China); Gu, Rong-Min [Department of Chemistry, Tianjin University, Tianjin 300072 (China); Collaborative Innovation Center of Chemical Science and Engineer (Tianjin), Tianjin University, Tianjin 300072 (China); Sun, Shuai [Key Laboratory for Green Chemical Technology of Ministry of Education, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300072 (China); Collaborative Innovation Center of Chemical Science and Engineer (Tianjin), Tianjin University, Tianjin 300072 (China); Li, Ming-Wei, E-mail: mingweili@tju.edu.cn [Department of Chemistry, Tianjin University, Tianjin 300072 (China); Collaborative Innovation Center of Chemical Science and Engineer (Tianjin), Tianjin University, Tianjin 300072 (China)

    2015-04-15

    Highlights: • LiMn{sub 0.6}Fe{sub 0.4}PO{sub 4}/C cathode material shows enhanced rate capability. • The Fe doped in the partial Mn sites could significantly facilitate the Li ions transfer. • The enhanced Li{sup +} ions diffusion contributes to the optimized rate capability of LiMn{sub 0.6}Fe{sub 0.4}PO{sub 4}. • ACM carbonization forms well carbon coating and a 3D carbon network structure. - Abstract: To enhance the rate and cyclic performances of LiMnPO{sub 4} cathode material for lithium-ion batteries, Mn is partially substituted with Fe, and LiMn{sub 1−x}Fe{sub x}PO{sub 4} (x = 0.2, 0.3, 0.4, 0.5) solid solutions are synthesized and investigated. Amphiphilic carbonaceous material (ACM) forms well carbon coating and connects the LiMn{sub 1−x}Fe{sub x}PO{sub 4} crystallites by a three-dimensional (3D) carbon network. The synergetic Fe substitution and carbon connection obviously improve the samples’ rate capacities and cyclic stability. The optimized LiMn{sub 0.6}Fe{sub 0.4}PO{sub 4}/C sample delivers discharge capacities of 160 mA h g{sup −1} at 0.05 C, 148 mA h g{sup −1} at 1 C, and 115 mA h g{sup −1} at 20 C. All samples have well capacity retention (>92%) after 50 charge/discharge cycles at 1 C. The enhanced electrochemical properties are mainly attributed to the improvement of Li ion and electron transport in the LiMn{sub 1−x}Fe{sub x}PO{sub 4}/C samples, respectively mainly resulting from their modified crystal structures caused by Fe substitution and the 3D carbon coating/connection originating from ACM carbonization. LiMn{sub 1−x}Fe{sub x}PO{sub 4} materials exhibit two discharge plateaus at ∼4.0 and ∼3.5 V (vs. Li{sup +}/Li), whose heights respectively reflect the redox potentials of Mn{sup 3+}/Mn{sup 2+} and Fe{sup 3+}/Fe{sup 2+} couples. The plateaus’ lengths correspond to the Mn/Fe ratio in LiMn{sub 1−x}Fe{sub x}PO{sub 4} and are affected by the kinetic behavior of samples. Though the ∼4.0 V plateau shrinks with

  13. New Insights into Mn1−xZnxFe2O4 via Fabricating Magnetic Photocatalyst Material BiVO4/Mn1−xZnxFe2O4

    Directory of Open Access Journals (Sweden)

    Taiping Xie

    2018-02-01

    Full Text Available BiVO4/Mn1−xZnxFe2O4 was prepared by the impregnation roasting method. XRD (X-ray Diffractometer tests showed that the prepared BiVO4 is monoclinic crystal, and the introduction of Mn1−xZnxFe2O4 does not change the crystal structure of BiVO4. The introduction of a soft-magnetic material, Mn1−xZnxFe2O4, was beneficial to the composite photocatalyst’s separation from the liquid solution using an extra magnet after use. UV-vis spectra analysis indicated that Mn1−xZnxFe2O4 enhanced the absorption intensity of visible light for BiVO4. EIS (electrochemical impedance spectroscopy investigation revealed that the introduction of Mn1−xZnxFe2O4 enhanced the conductivity of BiVO4, further decreasing its electron transfer impedance. The photocatalytic efficiency of BiVO4/Mn1−xZnxFe2O4 was higher than that of pure BiVO4. In other words, Mn1−xZnxFe2O4 could enhance the photocatalytic reaction rate.

  14. Phase structures of the black Dp-D(p+4)-brane system in various ensembles II: electrical and thermodynamic stability

    International Nuclear Information System (INIS)

    Xiao, Zhiguang; Zhou, Da

    2015-01-01

    By incorporating the electrical stability condition into the discussion, we continue the study on the thermodynamic phase structures of the Dp-D(p+4) black brane in GG, GC, CG, CC ensembles defined in our previous paper http://dx.doi.org/10.1007/JHEP07(2015)134. We find that including the electrical stability conditions in addition to the thermal stability conditions does not modify the phase structure of the GG ensemble but puts more constraints on the parameter space where black branes can stably exist in GC, CG, CC ensembles. In particular, the van der Waals-like phase structure which was supposed to be present in these ensembles when only thermal stability condition is considered would no longer be visible, since the phase of the small black brane is unstable under electrical fluctuations. However, the symmetry of the phase structure by interchanging the two kinds of brane charges and potentials is still preserved, which is argued to be the result of T-duality.

  15. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    Energy Technology Data Exchange (ETDEWEB)

    Cassinotto, Christophe, E-mail: christophe.cassinotto@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); INSERM U1053, Université Bordeaux, Bordeaux (France); Feldis, Matthieu, E-mail: matthieu.feldis@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Vergniol, Julien, E-mail: julien.vergniol@chu-bordeaux.fr [Centre D’investigation de la Fibrose Hépatique, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Mouries, Amaury, E-mail: amaury.mouries@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); Cochet, Hubert, E-mail: hubert.cochet@chu-bordeaux.fr [Department of Diagnostic and Interventional Imaging, Hôpital Haut-Lévêque, Centre Hospitalier Universitaire et Université de Bordeaux, 1 Avenue de Magellan, 33604 Pessac (France); and others

    2015-08-15

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan{sup ®} as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic

  16. MR relaxometry in chronic liver diseases: Comparison of T1 mapping, T2 mapping, and diffusion-weighted imaging for assessing cirrhosis diagnosis and severity

    International Nuclear Information System (INIS)

    Cassinotto, Christophe; Feldis, Matthieu; Vergniol, Julien; Mouries, Amaury; Cochet, Hubert

    2015-01-01

    Highlights: • The use of MR to classify cirrhosis in different stages is a new interesting field. • We compared liver and spleen T1 mapping, T2 mapping and diffusion-weighted imaging. • MR relaxometry using liver T1 mapping is accurate for the diagnosis of cirrhosis. • Liver T1 mapping shows that values increase with the severity of cirrhosis. • Diffusion-weighted imaging is less accurate than T1 mapping while T2 mapping is not reliable. - Abstract: Background: MR relaxometry has been extensively studied in the field of cardiac diseases, but its contribution to liver imaging is unclear. We aimed to compare liver and spleen T1 mapping, T2 mapping, and diffusion-weighted MR imaging (DWI) for assessing the diagnosis and severity of cirrhosis. Methods: We prospectively included 129 patients with normal (n = 40) and cirrhotic livers (n = 89) from May to September 2014. Non-enhanced liver T1 mapping, splenic T2 mapping, and liver and splenic DWI were measured and compared for assessing cirrhosis severity using Child-Pugh score, MELD score, and presence or not of large esophageal varices (EVs) and liver stiffness measurements using Fibroscan ® as reference. Results: Liver T1 mapping was the only variable demonstrating significant differences between normal patients (500 ± 79 ms), Child-Pugh A patients (574 ± 84 ms) and Child-Pugh B/C patients (690 ± 147 ms; all p-values <0.00001). Liver T1 mapping had a significant correlation with Child-Pugh score (Pearson's correlation coefficient of 0.46), MEDL score (0.30), and liver stiffness measurement (0.52). Areas under the receiver operating characteristic curves of liver T1 mapping for the diagnosis of cirrhosis (O.85; 95% confidence intervals (CI), 0.77–0.91), Child-Pugh B/C cirrhosis (0.87; 95%CI, 0.76–0.93), and large EVs (0.75; 95%CI, 0.63–0.83) were greater than that of spleen T2 mapping, liver and spleen DWI (all p-values < 0.01). Conclusion: Liver T1 mapping is a promising new diagnostic tool for

  17. Endometrial cancer with cervical stromal invasion: diagnostic accuracy of diffusion-weighted and dynamic contrast enhanced MR imaging at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Gigin; Lu, Hsin-Ying [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chang Gung Memorial Hospital at Linkou, Clinical Phenome Center, Guishan, Taoyuan (China); Huang, Yu-Ting; Lin, Yu-Chun; Ng, Shu-Hang; Ng, Koon-Kwan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Institute for Radiological Research, Guishan, Taoyuan (China); Chao, Angel; Lai, Chyong-Huey [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Obstetrics and Gynecology and Gynecologic Cancer Research Center, Guishan, Taoyuan (China); Yang, Lan-Yan [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Clinical Trial Center, Guishan, Taoyuan (China); Wu, Ren-Chin [Chang Gung Memorial Hospital at Linkou and Chang Gung University, Department of Pathology, Guishan, Taoyuan (China)

    2017-05-15

    To compare the diagnostic accuracy of diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging for detecting cervical stromal invasion in endometrial cancer. Eighty-three consecutive women with endometrial cancer underwent preoperative evaluation in a 3-T unit, including T2-weighted, DW (b = 0 and 1000 s/mm{sup 2}), and DCE MR imaging. Two radiologists independently assessed presence of cervical stromal invasion, with histopathological reference as gold standard. For assessing cervical stromal invasion, the diagnostic accuracy, sensitivity, and specificity, respectively for Reader 1/Reader 2, were as follows: DW MR imaging - 95.2 %/91.6 %, 91.7 %/100 %, and 95.8 %/90.1 %; DCE MR imaging - 91.6 %/88 %, 58.3 %/50 %, and 97.2 %/94.4 %. The diagnostic performance of DW MR imaging (Reader 1: areas under the receiver operating characteristic curve (AUC) = 0.98; Reader 2: AUC = 0.97) was significantly higher than that of DCE MR imaging (p = 0.009 for Reader 2) or T2-weighted MR imaging (Reader 1: p = 0.006; Reader 2: p = 0.013). Patients with cervical stromal invasion showed a significantly greater canal width (p < 0.0001) and myometrial invasion extent (p = 0.006). DW MR imaging has superior diagnostic performance compared with DCE MR imaging in the detection of cervical stromal invasion. (orig.)

  18. An efficient sequence for fetal brain imaging at 3T with enhanced T1 contrast and motion robustness.

    Science.gov (United States)

    Ferrazzi, Giulio; Price, Anthony N; Teixeira, Rui Pedro A G; Cordero-Grande, Lucilio; Hutter, Jana; Gomes, Ana; Padormo, Francesco; Hughes, Emer; Schneider, Torben; Rutherford, Mary; Kuklisova Murgasova, Maria; Hajnal, Joseph V

    2018-07-01

    Ultrafast single-shot T 2 -weighted images are common practice in fetal MR exams. However, there is limited experience with fetal T 1 -weighted acquisitions. This study aims at establishing a robust framework that allows fetal T 1 -weighted scans to be routinely acquired in utero at 3T. A 2D gradient echo sequence with an adiabatic inversion was optimized to be robust to fetal motion and maternal breathing optimizing grey/white matter contrast at the same time. This was combined with slice to volume registration and super resolution methods to produce volumetric reconstructions. The sequence was tested on 22 fetuses. Optimized grey/white matter contrast and robustness to fetal motion and maternal breathing were achieved. Signal from cerebrospinal fluid (CSF) and amniotic fluid was nulled and 0.75 mm isotropic anatomical reconstructions of the fetal brain were obtained using slice-to-volume registration and super resolution techniques. Total acquisition time for a single stack was 56 s, all acquired during free breathing. Enhanced sensitivity to normal anatomy and pathology with respect to established methods is demonstrated. A direct comparison with a 3D spoiled gradient echo sequence and a controlled motion experiment run on an adult volunteer are also shown. This paper describes a robust framework to perform T 1 -weighted acquisitions and reconstructions of the fetal brain in utero. Magn Reson Med 80:137-146, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic

  19. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gang, QiangQiang, E-mail: rousikang@163.com; Zhang, Jianing, E-mail: 1325916060@qq.com; Hao, Peng, E-mail: 1043600590@qq.com; Xu, Yikai, E-mail: yikaivip@163.com

    2013-11-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy.

  20. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    International Nuclear Information System (INIS)

    Gang, QiangQiang; Zhang, Jianing; Hao, Peng; Xu, Yikai

    2013-01-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy

  1. Basic evaluation of the new pulse sequence for simultaneous acquisition of T1- and T2-weighted images

    International Nuclear Information System (INIS)

    Kurose, Atsunari; Takahashi, Tohru; Ohishi, Tae; Ishikawa, Akihiro

    2006-01-01

    A novel pulse sequence that enables simultaneous acquisition of T1-weighted (T1W) and T2-weighted (T2W) images is presented. In this new technique, the inversion recovery (IR) pulse of conventional fast inversion recovery (Fast IR) is replaced with a pulse train that consists of a fast spin echo (FSE) and 180(y)+90(x) for driven inversion (DI). By using a shorter T1 and independent k-space ordering, the first part of the sequence provides T2W images and the second part provides T1W images, thereby enabling simultaneous acquisition in a single scan time comparable to that of Fast IR. Signal simulation also was conducted, and this was compared with conventional scanning techniques using normal volunteers. In the human studies, both T1W and T2W images showed the same image quality as conventional images, suggesting the potential for this technique to replace the combination of Fast IR and T2W FSE for scan-time reduction. (author)

  2. High signal in the spinal cord on T2-weighted images in rapidly progressive tropical spastic paraparesis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, M.; Hara, A.; Murakami, T.; Ando, Y.; Uyama, E.; Mita, S.; Uchino, M. [Kumamoto Univ. (Japan). School of Medicine; Yamashita, T. [Kumamoto Univ. (Japan). School of Medicine; Dept. of Neurology, Kumamoto Univ. (Japan)

    2001-03-01

    We report a 59-year-old woman with human T-cell lymphotrophic virus type-I (HTLV-I) associated myelopathy/tropical spastic paraparesis who showed high signal in the cervical and thoracic spinal cord on T2-weighted and contrast enhancement on T1-weighted images. (orig.)

  3. Comparison of gadolinium-EOB-DTPA-enhanced and diffusion-weighted liver MRI for detection of small hepatic metastases.

    Science.gov (United States)

    Shimada, Kotaro; Isoda, Hiroyoshi; Hirokawa, Yuusuke; Arizono, Shigeki; Shibata, Toshiya; Togashi, Kaori

    2010-11-01

    To compare the accuracy of gadolinium ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI with that of diffusion-weighted MRI (DWI) in the detection of small hepatic metastases (2 cm or smaller). Forty-five patients underwent abdominal MRI at 3 T, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI (HASTE), DWI with a b-value of 500 s/mm(2) and contrast-enhanced MRI with Gd-EOB-DTPA. Two groups were assigned and compared: group A (T1WI, T2WI, HASTE and contrast-enhanced study with Gd-EOB-DTPA), and group B (T1WI, T2WI, HASTE and DWI). Two observers independently interpreted the images obtained in a random order. For all hepatic metastases, the diagnostic performance using each imaging set was evaluated by receiver-operating characteristic (ROC) curve analysis. A total of 51 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B, and the difference in the mean Az values between the two image sets was statistically significant, whereas, there were three metastases that lay near thin vessels or among multiple cysts and were better visualised in group B than in group A. Gd-EOB-DTPA-enhanced MRI showed higher accuracy in the detection of small metastases than DWI.

  4. T1-weighted MRI for the detection of coronary artery plaque haemorrhage

    International Nuclear Information System (INIS)

    Oei, May Lin; Ozgun, Murat; Seifarth, Harald; Bunck, Alexander; Fischbach, Roman; Heindel, Walter; Maintz, David; Orwat, Stefan; Botnar, Rene

    2010-01-01

    Hyperintense areas in atherosclerotic plaques on pre-contrast T1-weighted MRI have been shown to correlate with intraplaque haemorrhage. We evaluated the presence of T1 hyperintensity in coronary artery plaques in coronary artery disease (CAD) patients and correlated results with multi-detector computed tomography (MDCT) findings. Fifteen patients with CAD were included. Plaques detected by MDCT were categorised based on their Hounsfield number. T1-weighted inversion recovery (IR) MRI prepared coronary MRI for the detection of plaque and steady-state free-precession coronary MR-angiography for anatomical correlation was performed. After registration of MDCT and MRI, regions of interest were defined on MDCT-visible plaques and in corresponding vessel segments acquired with MRI. MDCT density and MR signal measurement were performed in each plaque. Forty-three plaques were identified with MDCT. With IR-MRI 5/43 (12%) plaques were hyperintense, 2 of which were non-calcified and 3 mixed. Average signal-to-noise and contrast-to-noise ratios of hyperintense plaques were 15.7 and 9.1, compared with 5.6 and 1.2 for hypointense plaques. Hyperintense plaques exhibited a significantly lower CT density than hypointense plaques (63.6 vs. 140.8). There was no correlation of plaque signal intensity with degree of stenosis. T1-weighted IR-MRI may be useful for non-invasive detection and characterisation of intraplaque haemorrhage in coronary artery plaques. (orig.)

  5. Prospective comparison of T2w-MRI and dynamic-contrast-enhanced MRI, 3D-MR spectroscopic imaging or diffusion-weighted MRI in repeat TRUS-guided biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Portalez, Daniel [Clinique Pasteur, 45, Department of Radiology, Toulouse (France); Rollin, Gautier; Mouly, Patrick; Jonca, Frederic; Malavaud, Bernard [Hopital de Rangueil, Department of Urology, Toulouse Cedex 9 (France); Leandri, Pierre [Clinique Saint Jean, 20, Department of Urology, Toulouse (France); Elman, Benjamin [Clinique Pasteur, 45, Department of Urology, Toulouse (France)

    2010-12-15

    To compare T2-weighted MRI and functional MRI techniques in guiding repeat prostate biopsies. Sixty-eight patients with a history of negative biopsies, negative digital rectal examination and elevated PSA were imaged before repeat biopsies. Dichotomous criteria were used with visual validation of T2-weighted MRI, dynamic contrast-enhanced MRI and literature-derived cut-offs for 3D-spectroscopy MRI (choline-creatine-to-citrate ratio >0.86) and diffusion-weighted imaging (ADC x 10{sup 3} mm{sup 2}/s < 1.24). For each segment and MRI technique, results were rendered as being suspicious/non-suspicious for malignancy. Sextant biopsies, transition zone biopsies and at least two additional biopsies of suspicious areas were taken. In the peripheral zones, 105/408 segments and in the transition zones 19/136 segments were suspicious according to at least one MRI technique. A total of 28/68 (41.2%) patients were found to have cancer. Diffusion-weighted imaging exhibited the highest positive predictive value (0.52) compared with T2-weighted MRI (0.29), dynamic contrast-enhanced MRI (0.33) and 3D-spectroscopy MRI (0.25). Logistic regression showed the probability of cancer in a segment increasing 12-fold when T2-weighted and diffusion-weighted imaging MRI were both suspicious (63.4%) compared with both being non-suspicious (5.2%). The proposed system of analysis and reporting could prove clinically relevant in the decision whether to repeat targeted biopsies. (orig.)

  6. Enhanced ferromagnetism, metal-insulator transition, and large magnetoresistance in La1-xCaxMn1-xRuxO3 free of eg-orbital double-exchange

    Science.gov (United States)

    Liu, M. F.; Du, Z. Z.; Liu, H. M.; Li, X.; Yan, Z. B.; Dong, S.; Liu, J.-M.

    2014-03-01

    The structure, ionic valences, magnetism, and magneto-transport behaviors of mixed valence oxides La1-xCaxMn1-xRuxO3 are systematically investigated. The simultaneous substitutions of La3+ and Mn3+ ions by Ca2+ and Ru4+, respectively, are confirmed by the structural and ionic valence characterizations, excluding the presence of Mn4+ and Ru3+ ions. The enhanced ferromagnetism, induced metal-insulator transition, and remarkable magnetoresistance effect are demonstrated when the substitution level x is lower than ˜0.6, in spite of the absence of the Mn3+-Ru4+ eg-orbital double-exchange. These anomalous magnetotransport effects are discussed based on the competing multifold interactions associated with the Mn3+-Ru4+ super-exchange and strong Ru4+-Ru4+ hopping, while the origins for the metal-insulator transition and magnetoresistance effect remain to be clarified.

  7. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model

    International Nuclear Information System (INIS)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U.; Grobholz, R.; Heilmann, M.; Michel, M.S.; Trojan, L.; Werner, A.; Rabe, J.; Schlemmer, H.P.

    2003-01-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k ep ).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k ep . Prostate carcinomas of the peripheral zone were demarcated by amplitude and k ep . In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k ep and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k ep reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [de

  8. Hepatic hemangioma: Correlation of enhancement types with diffusion-weighted MR findings and apparent diffusion coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan)], E-mail: gossy@par.odn.ne.jp; Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Yokoyama, Ryujiro; Kajita, Kimihiro [Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Tsuge, Yusuke [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan)

    2009-05-15

    Purpose: To correlate hepatic hemangioma enhancement types in gadolinium-enhanced magnetic resonance (MR) images with diffusion-weighted MR findings and apparent diffusion coefficients (ADCs). Materials and methods: Respiratory-triggered diffusion-weighted MR images (TR/TE, 2422/46 ms; parallel imaging factor, 2; b factor, 500 s/mm{sup 2}; number of averaging, 6) obtained in 35 patients with 44 hepatic hemangiomas diagnosed by gadolinium-enhanced MR and by follow-up imaging were retrospectively evaluated. Hemangiomas were classified into three enhancement types based on gadolinium-enhanced MR imaging findings: type I, early-enhancement type; type II, peripheral nodular enhancement type; type III, delayed enhancement type. Two blinded readers qualitatively assessed lesion sizes and signal intensities on T2-weighted turbo spin-echo and diffusion-weighted images. The ADCs of hemangiomas were also measured. Results: No significant difference was observed between the three enhancement types in terms of signal intensities on T2-weighted images. Signal intensities on diffusion-weighted images were lower in the order type I to III (P < .01), and mean ADCs were 2.18 x 10{sup -3}, 1.86 x 10{sup -3}, and 1.71 x 10{sup -3} mm{sup 2}/s for types I, II, and III, respectively (P < .01). No correlation was found between lesion sizes and ADCs. Conclusion: Hepatic hemangiomas were found to have enhancement type dependent signal intensities and ADCs on diffusion-weighted MR images. Further studies will have to substantiate that these diffusion patterns might reflect intratumoral blood flow or perfusion.

  9. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    International Nuclear Information System (INIS)

    Ganzetti, Marco; Mantini, Dante; Wenderoth, Nicole

    2015-01-01

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  10. Mapping pathological changes in brain structure by combining T1- and T2-weighted MR imaging data

    Energy Technology Data Exchange (ETDEWEB)

    Ganzetti, Marco; Mantini, Dante [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); University of Oxford, Department of Experimental Psychology, Oxford (United Kingdom); Wenderoth, Nicole [ETH Zurich, Neural Control of Movement Laboratory, Department of Health Sciences and Technology, Zurich (Switzerland); KU Leuven, Laboratory of Movement Control and Neuroplasticity, Faculty of Kinesiology and Rehabilitation Sciences, Leuven (Belgium)

    2015-09-15

    A workflow based on the ratio between standardized T1-weighted (T1-w) and T2-weighted (T2-w) MR images has been proposed as a new tool to study brain structure. This approach was previously used to map structural properties in the healthy brain. Here, we evaluate whether the T1-w/T2-w approach can support the assessment of structural impairments in the diseased brain. We use schizophrenia data to demonstrate the potential clinical utility of the technique. We analyzed T1-w and T2-w images of 36 schizophrenic patients and 35 age-matched controls. These were collected for the Function Biomedical Informatics Research Network (fBIRN) collaborative project, which had an IRB approval and followed the HIPAA guidelines. We computed T1-w/T2-w images for each individual and compared intensities in schizophrenic and control groups on a voxel-wise basis, as well as in regions of interest (ROIs). Our results revealed that the T1-w/T2-w image permits to discriminate brain regions showing group-level differences between patients and controls with greater accuracy than conventional T1-w and T2-w images. Both the ROIs and the voxel-wise analysis showed globally reduced gray and white matter values in patients compared to controls. Significantly reduced values were found in regions such as insula, primary auditory cortex, hippocampus, inferior longitudinal fasciculus, and inferior fronto-occipital fasciculus. Our findings were consistent with previous meta-analyses in schizophrenia corroborating the hypothesis of a potential ''disconnection'' syndrome in conjunction with structural alterations in local gray matter regions. Overall, our study suggested that the T1-w/T2-w technique permits to reliably map structural differences between the brains of patients and healthy individuals. (orig.)

  11. Detailed T1-Weighted Profiles from the Human Cortex Measured in Vivo at 3 Tesla MRI.

    Science.gov (United States)

    Ferguson, Bart; Petridou, Natalia; Fracasso, Alessio; van den Heuvel, Martijn P; Brouwer, Rachel M; Hulshoff Pol, Hilleke E; Kahn, René S; Mandl, René C W

    2018-04-01

    Studies into cortical thickness in psychiatric diseases based on T1-weighted MRI frequently report on aberrations in the cerebral cortex. Due to limitations in image resolution for studies conducted at conventional MRI field strengths (e.g. 3 Tesla (T)) this information cannot be used to establish which of the cortical layers may be implicated. Here we propose a new analysis method that computes one high-resolution average cortical profile per brain region extracting myeloarchitectural information from T1-weighted MRI scans that are routinely acquired at a conventional field strength. To assess this new method, we acquired standard T1-weighted scans at 3 T and compared them with state-of-the-art ultra-high resolution T1-weighted scans optimised for intracortical myelin contrast acquired at 7 T. Average cortical profiles were computed for seven different brain regions. Besides a qualitative comparison between the 3 T scans, 7 T scans, and results from literature, we tested if the results from dynamic time warping-based clustering are similar for the cortical profiles computed from 7 T and 3 T data. In addition, we quantitatively compared cortical profiles computed for V1, V2 and V7 for both 7 T and 3 T data using a priori information on their relative myelin concentration. Although qualitative comparisons show that at an individual level average profiles computed for 7 T have more pronounced features than 3 T profiles the results from the quantitative analyses suggest that average cortical profiles computed from T1-weighted scans acquired at 3 T indeed contain myeloarchitectural information similar to profiles computed from the scans acquired at 7 T. The proposed method therefore provides a step forward to study cortical myeloarchitecture in vivo at conventional magnetic field strength both in health and disease.

  12. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanharawi, Imane El; Tzarouchi, Loukia [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Cardoen, Liesbeth [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude [Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Hopital Robert Debre, APHP, Service d' Endocrinologie Pediatrique, Paris (France); Elmaleh-Berges, Monique [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Inserm U1141, DHU PROTECT, Paris (France); Alison, Marianne [Hopital Robert Debre, APHP, Service de Radiologie Pediatrique, Paris (France); Universite Paris Diderot, Paris (France); Inserm U1141, DHU PROTECT, Paris (France)

    2017-05-15

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting. (orig.)

  13. High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis.

    Science.gov (United States)

    El Sanharawi, Imane; Tzarouchi, Loukia; Cardoen, Liesbeth; Martinerie, Laetitia; Leger, Juliane; Carel, Jean-Claude; Elmaleh-Berges, Monique; Alison, Marianne

    2017-05-01

    In anterior pituitary deficiency, patients with non visible pituitary stalk have more often multiple deficiencies and persistent deficiency than patients with visible pituitary stalk. To compare the diagnostic value of a high-resolution heavily T2-weighted sequence to 1.5-mm-thick unenhanced and contrast-enhanced sagittal T1-weighted sequences to assess the presence of the pituitary stalk in children with ectopic posterior pituitary gland. We retrospectively evaluated the MRI data of 14 children diagnosed with ectopic posterior pituitary gland between 2010 and 2014. We evaluated the presence of a pituitary stalk using a sagittal high-resolution heavily T2-weighted sequence and a 1.5-mm sagittal T1-weighted turbo spin-echo sequence before and after contrast medium administration. A pituitary stalk was present on at least one of the sequences in 10 of the 14 children (71%). T2-weighted sequence depicted the pituitary stalk in all 10 children, whereas the 1.5-mm-thick T1-weighted sequence depicted 2/10 (20%) before contrast injection and 8/10 (80%) after contrast injection (P=0.007). Compared with 1.5-mm-thick contrast-enhanced T1-weighted sequences, high-resolution heavily T2-weighted sequence demonstrates better sensitivity in detecting the pituitary stalk in children with ectopic posterior pituitary gland, suggesting that contrast injection is unnecessary to assess the presence of a pituitary stalk in this setting.

  14. Bilateral hyperintense basal ganglia on T1-weighted image

    International Nuclear Information System (INIS)

    Baik, Seung Kug; Ahn, Woo Hyun; Choi, Han Yong; Kim, Bong Gi

    1994-01-01

    Bilateral high signal intensity in basal ganglia on T1-weighted images is unusual, the purpose of this study is to describe the pattern of high signal intensity and underlying disease. During the last three years, 8 patients showed bilateral high signal intensity in basal ganglia on T1-weighted image, as compared with cerebral white matter. Authors analyzed the images and underlying causes retrospectively. Of 8 patients, 5 were male and 3 were female. The age ranged from 15 days to 79 years. All patient were examined by a 0.5T superconductive MRI. Images were obtained by spin echo multislice technique. Underlying causes were 4 cases of hepatopathy, 2 cases of calcium metabolism disorder, and one case each of neurofibromatosis and hypoxic brain injury. These process were bilateral in all cases and usually symmetric. In all cases the hyperintense areas were generally homogenous without mass effect or edema, although somewhat nodular appearance was seen in neurofibromatosis. Lesions were located in the globus pallidus and internal capsule in hepatopathy and neurofibromatosis, head of the caudate nucleus in disorder of calcum metabolism, and the globus pallidus in hypoxic brain injury. Although this study is limited by its patient population, bilateral hyperintense basal ganglia is associated with various disease entities. On analysis of hyperintense basal ganglia lesion, the knowledge of clinical information improved diagnostic accuracy

  15. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Mahon, R; Weiss, E; Karki, K; Hugo, G; Ford, J

    2016-01-01

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  16. SU-F-R-35: Repeatability of Texture Features in T1- and T2-Weighted MR Images

    Energy Technology Data Exchange (ETDEWEB)

    Mahon, R; Weiss, E; Karki, K; Hugo, G [Virginia Commonwealth University, Richmond, VA (United States); Ford, J [University of Miami Miller School of Medicine, Miami, FL (United States)

    2016-06-15

    Purpose: To evaluate repeatability of lung tumor texture features from inspiration/expiration MR image pairs for potential use in patient specific care models and applications. Repeatability is a desirable and necessary characteristic of features included in such models. Methods: T1-weighted Volumetric Interpolation Breath-Hold Examination (VIBE) and/or T2-weighted MRI scans were acquired for 15 patients with non-small cell lung cancer before and during radiotherapy for a total of 32 and 34 same session inspiration-expiration breath-hold image pairs respectively. Bias correction was applied to the VIBE (VIBE-BC) and T2-weighted (T2-BC) images. Fifty-nine texture features at five wavelet decomposition ratios were extracted from the delineated primary tumor including: histogram(HIST), gray level co-occurrence matrix(GLCM), gray level run length matrix(GLRLM), gray level size zone matrix(GLSZM), and neighborhood gray tone different matrix (NGTDM) based features. Repeatability of the texture features for VIBE, VIBE-BC, T2-weighted, and T2-BC image pairs was evaluated by the concordance correlation coefficient (CCC) between corresponding image pairs, with a value greater than 0.90 indicating repeatability. Results: For the VIBE image pairs, the percentage of repeatable texture features by wavelet ratio was between 20% and 24% of the 59 extracted features; the T2-weighted image pairs exhibited repeatability in the range of 44–49%. The percentage dropped to 10–20% for the VIBE-BC images, and 12–14% for the T2-BC images. In addition, five texture features were found to be repeatable in all four image sets including two GLRLM, two GLZSM, and one NGTDN features. No single texture feature category was repeatable among all three image types; however, certain categories performed more consistently on a per image type basis. Conclusion: We identified repeatable texture features on T1- and T2-weighted MRI scans. These texture features should be further investigated for use

  17. Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences.

    Science.gov (United States)

    Lee, Hoseok; Ahn, Joong Mo; Kang, Yusuhn; Oh, Joo Han; Lee, Eugene; Lee, Joon Woo; Kang, Heung Sik

    2018-01-01

    To compare the T1-weighted spectral presaturation with inversion-recovery sequences (T1 SPIR) with T2-weighted turbo spin-echo sequences (T2 TSE) on 3T magnetic resonance arthrography (MRA) in the evaluation of the subscapularis (SSC) tendon tear with arthroscopic findings as the reference standard. This retrospective study included 120 consecutive patients who had undergone MRA within 3 months between April and December 2015. Two musculoskeletal radiologists blinded to the arthroscopic results evaluated T1 SPIR and T2 TSE images in separate sessions for the integrity of the SSC tendon, examining normal/articular-surface partial-thickness tear (PTTa)/full-thickness tear (FTT). Diagnostic performance of T1 SPIR and T2 TSE was calculated with arthroscopic results as the reference standard, and sensitivity, specificity, and accuracy were compared using the McNemar test. Interobserver agreement was measured with kappa (κ) statistics. There were 74 SSC tendon tears (36 PTTa and 38 FTT) confirmed by arthroscopy. Significant differences were found in the sensitivity and accuracy between T1 SPIR and T2 TSE using the McNemar test, with respective rates of 95.9-94.6% vs. 71.6-75.7% and 90.8-91.7% vs. 79.2-83.3% for detecting tear; 55.3% vs. 31.6-34.2% and 85.8% vs. 78.3-79.2%, respectively, for FTT; and 91.7-97.2% vs. 58.3-61.1% and 89% vs. 78-79.3%, respectively, for PTTa. Interobserver agreement for T1 SPIR was almost perfect for T1 SPIR (κ = 0.839) and substantial for T2 TSE (κ = 0.769). T1-weighted spectral presaturation with inversion-recovery sequences is more sensitive and accurate compared to T2 TSE in detecting SSC tendon tear on 3T MRA.

  18. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    International Nuclear Information System (INIS)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H.; Walter, Oliver; Gieseke, Juergen

    2007-01-01

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  19. Intra-individual comparison of image contrast in SPIO-enhanced liver MRI at 1.5T and 3.0T

    Energy Technology Data Exchange (ETDEWEB)

    Falkenhausen, Marcus von; Meyer, Carsten; Lutterbey, Goetz; Morakkabati, Nuschin; Bloemer, Renate; Willinek, Winfried A.; Kuhl, Christiane K.; Schild, Hans H. [University of Bonn, Department of Radiology, Bonn (Germany); Walter, Oliver [Leibniz-Institute for Science Education, Kiel (Germany); Gieseke, Juergen [University of Bonn, Department of Radiology, Bonn (Germany); Philips Medical Systems, Hamburg (Germany)

    2007-05-15

    The purpose of the study was to examine if the higher susceptibility at 3.0 Tesla (T) compared to 1.5 T will affect the contrast in MR imaging of the liver after application of superparamagnetic iron oxide particles (SPIO). The study was approved by our institutional review board and informed consent was obtained. Seventeen healthy volunteers were examined in a prospective, intra-individual comparative study within one day on a 1.5 T and a 3.0 T MRI system. T2 weighted TSE sequences were acquired after bolus injection of a SPIO contrast agent. Image contrast and signal to noise ratio (SNR) were compared between the field strengths. Image contrast was calculated between the liver tissue and the kidneys / spleen / muscles and fluids. The students'T-test was used for statistical analysis. No influence of the higher field strength could be observed on image contrast except for the liver / muscle contrast. This was due to a distinct SNR increase of the muscle tissue at 3.0 T as a result of their relaxation properties. The higher susceptibility at 3.0 T compared to 1.5 T does not translate into a stronger signal attenuation of the SPIO enhanced liver parenchyma. (orig.)

  20. Magnetic Resonance Cholangiopancreatography: Image Quality, Ductal Morphology, and Value of Additional T2- and T1-weighted Sequences for the Assessment of Suspected Pancreatic Cancer

    International Nuclear Information System (INIS)

    Lopez Haenninen, E.; Ricke, H.; Amthauer, H.; Roettgen, R.; Boehmig, M.; Langrehr, J.; Pech, M.; Denecke, T.; Rosewicz, S.; Felix, R.

    2005-01-01

    Purpose: To assess image quality and duct morphology on magnetic resonance cholangiopancreatography (MRCP) and also the value of additional T2- and T1-weighted sequences for differentiation of benignity and malignancy in patients with suspected pancreatic tumors. Material and Methods: One-hundred-and-fourteen patients received MRCP and unenhanced and contrast material-enhanced MR imaging. MR results were analyzed independently by two blinded readers, and subsequently correlated with the results from surgery, biopsy, and follow-up. Assessment included the evaluation of image quality, duct visualization and morphology, and the differentiation of pancreatic lesion status (benign versus malignant).Results: Overall, 49 patients had benign final diagnoses, while 65 had a malignant diagnosis. Image quality of single-shot thick-slab MRCP was rated significantly better than the MIP images of multisection MRCP. With MRCP alone, the two readers' accuracy in the assessment of pancreatic lesion status was 72% (95% CI, 64% to 83%) and 69% (95% CI, 56% to 77%), respectively; with the addition of T2- and T1-weighted images the accuracy significantly improved to 89% (95% CI, 82% to 95%) and 84% (95% CI, 77% to 92%) for readers 1 and 2, respectively. Conclusion: Single-shot thick-slab MRCP and multisection MRCP provide complementary results; however, single-shot MRCP had superior image quality. Moreover, assessment of ductal morphology with MRCP alone facilitated the diagnosis of different pathologic conditions of the pancreatobiliary system in the majority of patients. However, with the addition of T2- and T1-weighted sequences the overall diagnostic accuracy was significantly improved and thus we consider that a comprehensive MR approach should comprise both MRCP techniques and parenchymal sequences

  1. Structural, magnetic and magnetocaloric properties of La{sub 0.7}Ca{sub 0.2}Sr{sub 0.1}Mn{sub 1−x}Cr{sub x}O{sub 3} compounds with x = 0, 0.05 and 0.1

    Energy Technology Data Exchange (ETDEWEB)

    Dhahri, Ah., E-mail: dhahri.ahmad@outlook.fr [Laboratoire de Physique Appliquée, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Jemmali, M. [Laboratoire des Sciences des Matériaux et de l’Environnement, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Taibi, K. [Département SDM, FGMGP/USTHB, 16311 (Algeria); Dhahri, E. [Laboratoire de Physique Appliquée, Faculté des Sciences de Sfax, BP 1171, Université de Sfax, 3000 (Tunisia); Hlil, E.K. [Institut Néel, CNRS et Université J. Fourier, BP 166, 38042 Grenoble (France)

    2015-01-05

    Highlights: • The samples crystallize in the rhombohedral structure with the R3{sup ¯}c space group. • Enhancement of T{sub C} for the rhombohedral samples. • The relative cooling power increases with Cr-doping. • All samples exhibit a large magnetocaloric effect. • High values of the magnetoresistance in all samples. - Abstract: Structural, magnetic and magnetocaloric properties of La{sub 0.7}Sr{sub 0.1}Ca{sub 0.2}Mn{sub 1−x}Cr{sub x}O{sub 3} compounds with x = 0, 0.05 and 0.1 have been investigated to shed light on Cr-doping influence. X-ray diffraction studies show that all samples crystallize in the rhombohedral symmetry with R3{sup ¯}c space group. Rietveld refinement structure shows that the insertion of Cr in Mn network modifies the structural parameters such as the volume, Mn–O–Mn angles and the Mn–O bond length. The substitution of Mn by Cr decreases the 2p-3d hybridization between O and Mn ions, reduces the bandwidth and increases the electron–phonon coupling. The investigation of magnetic and magnetocaloric properties reveals that the samples exhibit a paramagnetic(PM)–ferromagnetic (FM) transition with decreasing Curie temperature (T{sub C}) from 294 K to 255 K when Cr doping level increases. The magnetic entropy change (ΔS{sub M}{sup max}) also decreases from 6.20 J kg{sup −1} K{sup −1} for x = 0 to3.80 J kg{sup −1} K{sup −1} for x = 0.1, while the relative cooling power (RCP) increases from 234.5 to 240 J kg{sup −1}, respectively, under a magnetic field of 5 T. These outcomes suggest that Mn-site Cr doping inhibits the enhancement of the magnetocaloric effect in some perovskite manganites. This is explained by the weakening of the ferromagnetic double-exchange interaction between Mn{sup 3+} and Mn{sup 4+} ions.

  2. Myocardial area at risk after ST-elevation myocardial infarction measured with the late gadolinium enhancement after scar remodeling and T2-weighted cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Lønborg, Jacob; Engstrøm, Thomas; Mathiasen, Anders B

    2011-01-01

    To evaluate the myocardial area at risk (AAR) measured by the endocardial surface area (ESA) method on late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) when applied after scar remodeling (3 months after index infarction) compared to T2-weighted CMR imaging. One hundred...... and sixty nine patients with ST-elevation myocardial infarction, treated with primary percutaneous coronary intervention, underwent one CMR within 1 week after index treatment to determine the AAR with T2-weighted imaging and a second scan 3 months after to measure AAR with the ESA method...

  3. Myocardial area at risk after ST-elevation myocardial infarction measured with the late gadolinium enhancement after scar remodeling and T2-weighted cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Lønborg, Jacob; Engstrøm, Thomas; Mathiasen, Anders B

    2012-01-01

    To evaluate the myocardial area at risk (AAR) measured by the endocardial surface area (ESA) method on late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) when applied after scar remodeling (3 months after index infarction) compared to T2-weighted CMR imaging. One hundred...... and sixty nine patients with ST-elevation myocardial infarction, treated with primary percutaneous coronary intervention, underwent one CMR within 1 week after index treatment to determine the AAR with T2-weighted imaging and a second scan 3 months after to measure AAR with the ESA method...

  4. Magnetic and transport properties of La0.3Ca0.7Mn0.9T0.1O3 (T = Cr, Fe, and W)

    International Nuclear Information System (INIS)

    Sudyoadsuk, T.; Suryanarayanan, R.; Winotai, P.

    2005-01-01

    We have carried out structural, magnetic and magneto transport measurements of the electron-doped manganite La 0.3 Ca 0.7 MnO 3 substituted with 10% of Cr, Fe and W on the Mn site. The substitution by Cr, Fe and W suppresses the charge order transition present at 260 K in the parent compound. All the samples show a semiconducting behavior. Whereas the parent compound does not show any magneto resistance (MR) even in a field of 14 T, a maximum MR of 6% in 5 T at 25 K is observed for the Cr substituted sample that is attributed to a spin-cluster glass like states induced by Cr. The Fe and W substituted samples showed a MR of 1.5 and 3%, respectively which may be attributed to a smaller number of FM domains/spin-clusters and to an increase in anti-ferromagnetic interaction

  5. Whole-brain intracranial vessel wall imaging at 3 Tesla using cerebrospinal fluid-attenuated T1-weighted 3D turbo spin echo.

    Science.gov (United States)

    Fan, Zhaoyang; Yang, Qi; Deng, Zixin; Li, Yuxia; Bi, Xiaoming; Song, Shlee; Li, Debiao

    2017-03-01

    Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T 1 -weighted vessel wall imaging. Nonselective excitation and a flip-down radiofrequency pulse module were incorporated into a commercial 3D TSE sequence. A protocol based on the sequence was designed to achieve T 1 -weighted vessel wall imaging with whole-brain spatial coverage, enhanced CSF-signal suppression, and isotropic 0.5-mm resolution. Human volunteer and pilot patient studies were performed to qualitatively and quantitatively demonstrate the advantages of the sequence. Compared with the original sequence, the modified sequence significantly improved the T 1 -weighted image contrast score (2.07 ± 0.19 versus 3.00 ± 0.00, P = 0.011), vessel wall-to-CSF contrast ratio (0.14 ± 0.16 versus 0.52 ± 0.30, P = 0.007) and contrast-to-noise ratio (1.69 ± 2.18 versus 4.26 ± 2.30, P = 0.022). Significant improvement in vessel wall outer boundary sharpness was observed in several major arterial segments. The new 3D TSE sequence allows for high-quality T 1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T 1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  6. Magnetic properties of (Mn1-xRux)3Ga alloys

    International Nuclear Information System (INIS)

    Hori, T.; Akimitsu, M.; Miki, H.; Ohoyoama, K.; Yamaguchi, Y.

    2002-01-01

    We found that the pseudo binary alloys Mn 1-x Ru x 3 Ga, with 0.33≤x≤0.67, have an ordered b.c.c. structure. The lattice constant a is almost constant with respect to x: a=6.000 A for x=0.33 and a=5.992 A for x=0.67. For the alloy with x=0.33, i.e. Mn 2 RuGa, the magnetization is almost saturated in a field of 20 kOe. The saturation magnetization at 4.2 K is 23 emu/g, and the Curie temperature, T C , is 460 K. The T C of (Mn 1-x Ru x ) 3 Ga decreases almost linearly with increasing x, and it vanishes around x=0.67 (MnRu 2 Ga). We also determined atomic and magnetic structures from neutron diffraction experiments. The alloy Mn 2 RuGa (x=0.33) has an ordered structure of CuHg 2 Ti type; the magnetic Mn atoms mainly occupy the 4a (0,0,0) and 4d (3/4,3/4,3/4) sites. We also observed that the magnetic moments of Mn atoms on the 4a and 4d sites are antiparallel to each other; values of the magnetic moment are μ a =4.6 and μ d =3.3 μ B per Mn atom. (orig.)

  7. Clinical Study White Matter Atrophy in Patients with Mesial Temporal Lobe Epilepsy: Voxel-Based Morphometry Analysis of T1- and T2-Weighted MR Images

    International Nuclear Information System (INIS)

    Braga, B.; Yasuda, C.L.; Cendes, F.

    2012-01-01

    Introduction. Mesial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis is highly refractory to clinical treatment. MRI voxel-based morphometry (VBM) of T1-weighted images has revealed a widespread pattern of gray matter (GM) and white matter (WM) atrophy in MTLE. Few studies have investigated the role of T2-weighted images in revealing WM atrophy using VBM. Objectives. To compare the results of WM atrophy between T1- and T2-weighted images through VBM. Methods. We selected 28 patients with left and 27 with right MTLE and 60 normal controls. We analyzed T1- and T2- weighted images with SPM8, using VBM/DARTEL algorithm to extract maps of GM and WM. The second level of SPM was used to investigate areas of WM atrophy among groups. Results. Both acquisitions showed bilateral widespread WM atrophy. T1-weighted images showed higher sensibility to detect areas of WM atrophy in both groups of MTLE. T2-weighted images also showed areas of WM atrophy in a more restricted pattern, but still bilateral and with a large area of superposition with T1-weighted images. Conclusions. In MTLE, T1-weighted images are more sensitive to detect subtle WM abnormalities using VBM, compared to T2 images, although both present a good superposition of statistical maps. 1. Introduction The mesial temporal lobe epilepsy (MTLE) is highly refractory to pharmacological treatment [1], and it is the main group of epilepsy referred to the tertiary care hospitals for surgical treatment [2]. MTLE shows a good surgical prognosis, with satisfactory seizures control in 60-80% of the patients [3]. In approximately 65%

  8. Enhanced electrochemical performance of Ti substituted P2-Na2/3Ni1/4Mn3/4O2 cathode material for sodium ion batteries

    International Nuclear Information System (INIS)

    Zhao, Wenwen; Tanaka, Akinobu; Momosaki, Kyoko; Yamamoto, Shinji; Zhang, Fabi; Guo, Qixin; Noguchi, Hideyuki

    2015-01-01

    Highlights: • Ti substituted P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 cathode was synthesized. • Structural and electrochemical properties of Na 2/3 Ni 1/4 Ti x Mn 3/4-x O 2 were studied. • Ti substituted cathodes exhibit enhanced cycleability and rate performance. • Ti substitution has impact on stabilizing the P2 structure during cycling. -- Abstract: Ti substituted P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 cathode material with the composition of Na 2/3 Ni 1/4 Ti x Mn 3/4-x O 2 has been synthesized by solid state method. The influence of Ti substitution for Mn on the structure, morphology and electrochemical performances of P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 has been investigated. X-ray diffraction (XRD) results of Ti substituted sample show that they exhibit same diffraction patterns as those of pristine P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 . Progressive change in the lattice parameters of Ti substituted samples suggests that Mn was successfully substituted by Ti. In contrast to P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 which shows step-type voltage profiles, Ti substituted samples show sloping voltage profiles. Drastic capacity fade occurred for P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 cathode, while Ti substituted cathodes still show high capacity retention over 92% after 25 cycles at the voltage range of 2.0-4.3 V. Even cycled at high upper cut-off voltage of 4.5 V, Ti=0.20 sample can deliver a reversible capacity of 140 mAhg −1 with the capacity retention over 92% after 25 cycles. Furthermore, Ti substituted cathodes exhibit enhanced rate capability over pristine P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 cathode. Comparison of the Ex-situ XRD results of the cycled P2-Na 2/3 Ni 1/4 Mn 3/4 O 2 and its substituted samples provides evidence that the improved electrochemical performance of Ti substituted cathodes would be attributed to the stabilization of the structure with Ti substitution

  9. Mn induced 1 × 2 reconstruction in the τ-MnAl(0 0 1) surface

    Science.gov (United States)

    Guerrero-Sánchez, J.; Takeuchi, Noboru

    2018-05-01

    We report on first principles total energy calculations to describe the structural, electronic and magnetic properties of MnAl(0 0 1) surfaces. We have concentrated in structural models having 1 × 1 and 1 × 2 periodicities, since recent experiments of the similar MnGa(0 0 1) surface have found 1 × 1 and 1 × 2 reconstructions. Our calculations show the existence of two stable structures for different ranges of chemical potential. A 1 × 1 surface is stable for Al-rich conditions, whereas a Mn-induced 1 × 2 reconstruction appears after increasing the Mn chemical potential up to Mn-rich conditions. It is important to notice that experimentally, Mn rich conditions are important for improved magnetic properties. The Mn layers in both structures have ferromagnetic arrangements, but they are aligned antiferromagnetically with the almost no magnetic Al atoms. Moreover, the on top Mn atoms, which produce the 1 × 2 reconstruction, align antiferromagnetically with the second layer Mn atoms. These findings are similar to those obtained experimentally in MnGa thin films grown by molecular beam epitaxy. Therefore, this method could also be used to grow the proposed MnAl films.

  10. 3T MR Spin Echo T1 Weighted Image at Optimization of Flip Angle

    International Nuclear Information System (INIS)

    Lim, Chung Hwang; Bae, Sung Jin

    2009-01-01

    This study presents the optimization of flip angle (FA) to obtain higher contrast to noise ratio (CNR) and lower specific absorption rate (SAR). T1-weighted images of the cerebrum of brain were obtained from 50 degrees to 130 degrees FA with 10 interval. Signal to noise ratios (SNRs) were calculated for white matter (WM), gray matter (GM), and background noise. The proper FA was analyzed by T-test statistics and Kruskal-wallis analysis using R1 = 1- exp (-TR/T1) and Ernst angle cos = exp ((-TR/T1). The SNR of WM at 130 degrees FA is approximately 1.6 times higher than the SNR of WM at 50 degrees. The SNR of GM at 130 degrees FA is approximately 1.9 times higher than the SNR of GM at 50 degrees. Although the SNRs of WM and GM showed similar trends with the change of FA values, the slowdown point of decrease after linear fitting were different. While the SNR of WM started decreasing at 120 degrees FA, the SNR of GM started decreasing at less than 110 degrees. The highest SNRs of WM and GM were obtained at 130 degrees FA. The highest CNRs, however, were obtained at 80 degrees FA. Although SNR increased with the change of FA values from 50 degrees to 130 degrees at 3T SE T1WI, CNR was higher at 80 degrees FA than at the usually used 90 degrees FA. In addition, the SAR was decreased by using smaller FA. The CNR can be increased by using this optimized FA at 3T MR SE T1WI.

  11. Gadolinium-DTPA enhancement of VX-2 carcinoma of the rabbit kidney on Tl weighted magnetic resonance images

    International Nuclear Information System (INIS)

    Yancey, J.M.; Ackerman, N.; Kaude, J.V.; Googe, R.E.; Fitzsimmons, J.R.; Scott, K.N.; Mancuso, A.A.; Hackett, R.L.; Hager, D.A.; Caballero, S.; Florida Univ., Gainesville

    1987-01-01

    Experimental renal carcinoma was induced by percutaneous injection of VX-2 carcinoma cells into the left kidney in New Zealand white rabbits. Magnetic resonance imaging (MRI) was performed at 0.15 T before and after intravenous injection of 0.3 mmol gadolinium-DTPA (Gd-DTPA) per kg body weight. Gd-DTPA enhanced the tumors by increasing the signal intensity on T1 weighted images. The enhancement was evident immediately after Gd-DTPA injection, increasing during the observation time of 30 minutes. Histologically the areas of enhancement corresponded well to the viable tumor tissue. (orig.)

  12. Microwave absorption enhancement, magnetic coupling and ab initio electronic structure of monodispersed (Mn1-xCox)3O4 nanoparticles

    Science.gov (United States)

    Zhao, Pengfei; Liang, Chongyun; Gong, Xiwen; Gao, Ran; Liu, Jiwei; Wang, Min; Che, Renchao

    2013-08-01

    Monodispersed manganese oxide (Mn1-xCox)3O4 (0 nanoparticles, less than 10 nm size, are respectively synthesized via a facile thermolysis method at a rather low temperature, ranging from 90 to 100 °C, without any inertia gas for protection. The influences of the Co dopant content on the critical reaction temperature required for the nanoparticle formation, electronic band structures, magnetic properties, and the microwave absorption capability of (Mn1-xCox)3O4 are comprehensively investigated by means of both experimental and theoretical approaches including powder X-ray diffraction (XRD), electron energy loss spectroscopy (EELS), super conductivity quantum interference device (SQUID) examination, and first-principle simulations. Co is successfully doped into the Mn atomic sites of the (Mn1-xCox)3O4 lattice, which is further confirmed by EELS data acquired from one individual nanoparticle. Therefore, continuous solid solutions of well-crystallized (Mn1-xCox)3O4 products are achieved without any impurity phase or phase separation. With increases in the Co dopant concentration x from 0 to 0.5, the lattice parameters change systemically, where the overall saturation magnetization at 30 K increases due to the more intense coupling of the 3d electrons between Mn and Co, as revealed by simulations. The microwave absorption properties of the (Mn1-xCox)3O4 nanoparticles are examined between 2 and 18 GHz. The maximum absorption peak -11.0 dB of the x = 0 sample is enhanced to -11.5 dB for x = 0.2, -12.7 dB for x = 0.25, -15.6 dB for x = 0.33, and -24.0 dB for x = 0.5 respectively, suggesting the Co doping effects. Our results might provide novel insights into the understanding of the influences of metallic ion doping on the electromagnetic properties of metallic oxide nanomaterials.Monodispersed manganese oxide (Mn1-xCox)3O4 (0 nanoparticles, less than 10 nm size, are respectively synthesized via a facile thermolysis method at a rather low temperature, ranging from 90 to

  13. Volume magnetostriction at the AF-FRI metamagnetic transition in the itinerant-electron system Mn2-xTxSb (T=Co, Cr)

    International Nuclear Information System (INIS)

    Bartashevich, M.I.; Goto, T.; Baranov, N.V.; Gaviko, V.S.

    2004-01-01

    Mn 2 Sb is a ferrimagnet, and substitution of Co or Cr for Mn above the critical concentration results in the appearance of a spontaneous first-order magnetic phase transition from ferrimagnetic (FRI) to antiferromagnetic (AF) with decreasing temperature below T t . At T t a first-order field-induced AF-FRI transition is observed at a critical field B c . The spontaneous as well as the field induced AF-FRI transition is accompanied by a significant magnetovolume effect. Magnetization under high pressure up to 12 kbar, magnetostriction of Mn 1.8 Co 0.2 Sb and Mn 1.94 Cr 0.04 Sb as well as thermal expansion of the Mn 1-x Co x Sb system has been measured in order to clarify the origin of the contradictory experimental results on the pressure effect on B c and that on T t , implying opposite changes. The observed differences are explained by the found anomalous change of sign of the magnetovolume effect at the AF-FRI transition with decreasing temperature

  14. Hyperfine fields at 89Y nuclei in Y(Fesub(1-x)Tsub(x))2 (T=V, Mn, Co, Ni, Al) with low concentrations x

    International Nuclear Information System (INIS)

    Ichinose, Kazuyoshi; Yoshie, Hiroshi; Nagai, Hiroyuki; Tsujimura, Akira; Fujiwara, Katsuyuki.

    1983-01-01

    NMR of 89 Y nuclei in Y(Fesub(1-x)Tsub(x)) 2 (T=V, Mn, Co, Ni, Al) has been observed at 4.2K. Well-resolved satellite structures of Y resonance appear in these compounds. This shows that the Y hyperfine field is mainly due to the magnetic nearest neighbor atoms. The magnetic moment of T atoms is estimated by two methods: (i) the contribution of T atoms to the hyperfine field is proportional to the magnetic moments of Fe and T atoms and (ii) the well known empirical relation between the hyperfine field and the mean magnetic moment of alloys is used. These results are in good agreement with those in dilute T-Fe alloys except for T=Mn. The intensity ratio of satellite peaks is discussed based upon a statistical distribution of Fe and T atoms. (author)

  15. Dynamic Quantitative T1 Mapping in Orthotopic Brain Tumor Xenografts

    Directory of Open Access Journals (Sweden)

    Kelsey Herrmann

    2016-04-01

    Full Text Available Human brain tumors such as glioblastomas are typically detected using conventional, nonquantitative magnetic resonance imaging (MRI techniques, such as T2-weighted and contrast enhanced T1-weighted MRI. In this manuscript, we tested whether dynamic quantitative T1 mapping by MRI can localize orthotopic glioma tumors in an objective manner. Quantitative T1 mapping was performed by MRI over multiple time points using the conventional contrast agent Optimark. We compared signal differences to determine the gadolinium concentration in tissues over time. The T1 parametric maps made it easy to identify the regions of contrast enhancement and thus tumor location. Doubling the typical human dose of contrast agent resulted in a clearer demarcation of these tumors. Therefore, T1 mapping of brain tumors is gadolinium dose dependent and improves detection of tumors by MRI. The use of T1 maps provides a quantitative means to evaluate tumor detection by gadolinium-based contrast agents over time. This dynamic quantitative T1 mapping technique will also enable future quantitative evaluation of various targeted MRI contrast agents.

  16. The Impact of Gd-Eob-Dtpa-Enhanced MR Cholangiography in Biliary Diseases: Comparison with T2-Weighted MR Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Evrim Özmen

    2016-06-01

    Full Text Available Background: Contrast enhanced magnetic resonance cholangiography is a novel technique and promising method in demonstrating biliary tree anatomy and evaluating biliary disorders. However, to date, there are a limited number of studies that have focused on the impact of this technique. Aims: We aimed to evaluate the additional role of contrast enhanced MR cholangiography (MRC and compare contrast enhanced MRC with T2-weighted (w magnetic resonance cholangiopancreatography (MRCP in the diagnosis of biliary disorders. Study Design: Diagnostic accuracy study. Methods: The T2w-MRCP and contrast enhanced MRC sequences of 31 patients whose gold standard test results were available were scored visually for the existence of pathological findings with regard to any of the biliary diseases. Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA was used as the contrast agent. The correlation values were determined according to the statistical analysis made from those scores and the sensitivity, specificity and accuracy values of each sequence were detected as well. Results: We detected that the correlation values with gold standard methods of contrast enhanced MRC sequences were significantly higher than the ones of T2w-MRCP sequences. The correlation ratios of T2w-MRCP sequences were between 26 and 34%, while those for contrast enhanced MRC sequences were between 81 and 83% for the first reader and the correlation ratios of T2w-MRCP sequences were between 10 and 61%, whereas those of contrast enhanced MRC were between 79 and 81% for the second reader The mean sensitivity, specificity and accuracy values of T2w-MRCP sequences were 14.3-42.5%, 85-89.2% and 59.3-72.5%, respectively, while the mean sensitivity, specificity and accuracy values of contrast enhanced MRC sequences were 100%, 86.7% and 93.2-93.3%, respectively. Conclusion: We suggest that obtaining of contrast enhanced MRC sequences in addition to the T2w-MRCP can be useful in

  17. The Enhancement of Mg Corrosion Resistance by Alloying Mn and Laser-Melting

    Directory of Open Access Journals (Sweden)

    Youwen Yang

    2016-03-01

    Full Text Available Mg has been considered a promising biomaterial for bone implants. However, the poor corrosion resistance has become its main undesirable property. In this study, both alloying Mn and laser-melting were applied to enhance the Mg corrosion resistance. The corrosion resistance, mechanical properties, and microstructure of rapid laser-melted Mg-xMn (x = 0–3 wt % alloys were investigated. The alloys were composed of dendrite grains, and the grains size decreased with increasing Mn. Moreover, Mn could dissolve and induce the crystal lattice distortion of the Mg matrix during the solidification process. Mn ranging from 0–2 wt % dissolved completely due to rapid laser solidification. As Mn contents further increased up to 3 wt %, a small amount of Mn was left undissolved. The compressive strength of Mg-Mn alloys increased first (up to 2 wt % and then decreased with increasing Mn, while the hardness increased continuously. The refinement of grains and the increase in corrosion potential both made contributions to the enhancement of Mg corrosion resistance.

  18. Evaluation of iron colloid-enhanced T{sub 2}-weighted fast MR imaging of hepatocellular carcinoma. Comparison of SE, TSE and TGSE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Shuji; Suto, Yuji; Kamba, Masayuki; Yoshida, Kotarou; Ohta, Yoshio [Tottori Univ., Yonago (Japan). Faculty of Medicine

    1996-06-01

    We have applied chondroitin sulfate iron colloid (CSIC) as a contrast agent for MRI in detecting hepatocellular carcinoma (HCC) on conventional spin-echo sequences (SE). In this report, we evaluated CSIC-enhanced T{sub 2}-weighted fast MR imaging of HCC. MR imaging were performed before and after i.v. administration of CSIC in 15 patients with 46 HCCs. T{sub 2}-weighted SE (1800/80/2, 210 x 256 matrix), T{sub 2}-weighted turbo spin-echo (TSE1800) (1800/90/5, echo train length=7, 252 x 256 matrix), TSE (3500/90/5, echo train length=7, 252 x 256 matrix) (TSE7), TSE (3500/99/5, echo train length=11, 242 x 256 matrix) (TSE11) and T{sub 2}-weighted turbo-gradient spine-echo (TGSE) (4500/108/4, echo train length=33, 252 x 256 matrix) images were compared quantitatively and qualitatively. In all sequences, liver signal-to-noise ratio (SNR) was significantly decreased and lesion-to-liver contrast-to-noise ratio (CNR) was significantly increased after CSIC administration. Although decreased ratio in liver and tumor SNR caused by CSIC was smaller on TSE sequences compared with SE and TGSE, increased ratio in lesion-to-liver CNR was largest on TSE7. Either before or after i.v. administration of CSIC, the number of detectable lesions was largest on TSE7. TSE with used longer TR, TE and decreased echo factor was useful method for CSIC-enhanced abdominal MR imaging. (author)

  19. Intramolecular electron transfer in cyanide bridged adducts comprising Ru(II)/Ru(III) tetracarboxylate and [Mn(I)(CO)(CN)((t)BuNC)(4)] units.

    Science.gov (United States)

    Imhof, Wolfgang; Sterzik, Anke; Krieck, Sven; Schwierz, Markus; Hoffeld, Thomas; Spielberg, Eike T; Plass, Winfried; Patmore, Nathan

    2010-07-21

    Reaction of mixed valence ruthenium tetracarboxylates [Ru(2)(II,III)(R(1)COO)(2)(R(2)COO)(2)Cl] (R(1) = Me, R(2) = 2,4,6-(i)Pr-Ph or R(1) = R(2) = (t)Bu) with two equivalents of the octahedral manganese complex [Mn(I)(CO)(CN)((t)BuNC)(4)] leads to the formation of cyanide bridged heteronuclear coordination compounds of the general formula {[Ru(2)(II,III)(R(1)COO)(2)(R(2)COO)(2)][Mn(I)(CO)(CN)((t)BuNC)(4)](2)}Cl. In solution an intramolecular electron transfer from manganese towards the multiply bonded Ru(2) core occurs that is verified by EPR and IR spectroscopy, magnetic measurements and DFT calculations. Nevertheless, disproportionation of an initially formed {Mn(I)-Ru(2)(II,III)-Mn(I)}(+) adduct into {Mn(II)-Ru(2)(II,III)-Mn(I)}(2+) and {Mn(I)-Ru(2)(II,II)-Mn(I)} species cannot be completely ruled out.

  20. Comparison between T2-weighted MR and contrast-enhanced MR cholangiography in the evaluation of biliary anatomy in liver transplant donor candidates

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Wu Chunnan; Dong Yuru; Dong Yue; Zhang Huiqing; Zang Yunjin

    2008-01-01

    Objective: To compare conventional T 2 -weighted MR cholangiography (T 2 WI-MRC) with gadobenate dimeglumine enhanced T 1 -weighted MR cholangiography(CE-MRC) for evalution of biliary anatomy in liver transplant donor candidates. Methods: Thirty-two healthy liver transplant donor candidates were examined with two MR cholangiographic methods. For T 2 WI-MRC, a three-dimensional turbo spin-echo sequence and oblique coronal heavily T 2 -weighted thick-slab turbo spin-echo imaging sequence were performed. For CE-MRC, three-dimensional fat-suppressed spoiled gradient-echo sequences were performed, with a time delay of 60 minutes following the administration of gadobenate dimeglumine. To compare the depiction of biliary duct anatomy and the artifact caused by intestinal liquid and breathing between the two methods. Intraoperative cholangiography was the reference-standard examination. Results: The both methods depicted the biliary anatomy correctly in all 9 cases. The both methods showed the third branches of intrahepatic biliary duct clearly. T 2 WI-MRC showed interhepatic biliary duct before the third branches in 28 cases (87.5%), CE-MRC showed the same finding in 14 eases (43.8%). T 2 WI-MRC showed common bile ducts intermitantly in 2 cases, which were normal in CE-MRC and intraoperative cholangiography. Intestinal liquid affected the image quality of biliary duct in 6 cases (18.8%) performed with T 2 WI-MRC, but none with CE-MRC. The artifacts caused by breathing were not obvious in the either method. Conclusion: T 2 WI-MRC and CE-MRC both can be used to evaluate biliary anatomy of liver transplant donor candidates, but CE-MRC appears to be more accurate than T 2 WI-MRC. (authors)

  1. Ferromagnetism and transport in Mn and Mg co-implanted GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Kulbachinskii, V A [Moscow State University, Low Temperature Physics Department, 119992, GSP-2, Moscow (Russian Federation); Gurin, P V [Moscow State University, Low Temperature Physics Department, 119992, GSP-2, Moscow (Russian Federation); Danilov, Yu A [Physico-Technical Research Institute, University of Nizhny Novgorod, 603950, Nizhny Novgorod (Russian Federation); Malysheva, E I [Physico-Technical Research Institute, University of Nizhny Novgorod, 603950, Nizhny Novgorod (Russian Federation); Horikoshi, Y [School of science and engineering, Waseda university, 3-4-1, Okubo, Tokyo 169-8555 (Japan); Onomitsu, K [School of science and engineering, Waseda university, 3-4-1, Okubo, Tokyo 169-8555 (Japan)

    2007-03-15

    We investigated the influence of Mn and Mg co-implantation accompanied by rapid thermal annealing on magnetic and galvanomagnetic properties of p-GaAs. We characterized the samples with SQUID magnetometry and magnetotransport measurements in the temperature interval 4.2 K<T<400 K. Magnetization measurements reveal ferromagnetism up to 400 K (limited by the experimental setup) in all implanted samples. Temperature dependences of resistance, magnetoresistance and Hall effect have been measured in the temperature range 4.2{<=}T{<=}300 K. The anomalous Hall effect is visible up to 195 K and shows influence of ferromagnetism of Ga{sub 1-x}Mn{sub x}As solid solution on galvanomagnetic properties of holes. Above this temperature, ferromagnetism survives due to the MnAs and Ga{sub 1-x}Mn{sub x} clusters. The magnetoresistance changes from colossal negative to enhanced positive with increasing temperature near T = 35 K.

  2. Elucidation of the enhanced ferromagnetic origin in Mn-doped ZnO nanocrystals embedded into a SiO2 matrix

    International Nuclear Information System (INIS)

    Lee, Sejoon; Lee, Youngmin; Kim, Deukyoung

    2013-01-01

    The origin of the enhanced room temperature ferromagnetism in Mn-doped ZnO (ZnO:Mn) nanocrystals is investigated. ZnO:Mn nanocrystals, which were fabricated by using a laser irradiation method with a 248-nm KrF excimer laser, exhibited two-times increase in the spontaneous magnetization (∼0.4 emu/cm 3 at 300 K) compared to the ZnO:Mn thin film (∼0.2 emu/cm 3 at 300 K). The increased exchange integral of J 1 /k B = 51.6 K in ZnO:Mn nanocrystals, in comparison with the ZnO:Mn thin film (J 1 /k B = 46.9 K), is indicative of the enhanced ferromagnetic exchange interaction. This is attributed to the large number of acceptor defects in the SiO 2 -capped ZnO:Mn nanocrystals. Namely, the holes bound to the acceptor defects form microscopic bound-magnetic-polarons with Mn ions; hence, long-range ferromagnetic coupling is enhanced. The results suggest that ferromagnetism in ZnO-based dilute magnetic semiconductors can be controlled by modulating the density of native point defects, which can be chemically and thermodynamically modified during the material synthesis or preparation.

  3. Pressure dependence of resistivity and magnetic properties in a Mn1.9Cr0.1Sb alloy

    Directory of Open Access Journals (Sweden)

    D. V. Maheswar Repaka

    2017-12-01

    Full Text Available We report magnetic-field and hydrostatic pressure dependent electrical resistivity and magnetic properties of a Mn1.9Cr0.1Sb alloy. Upon cooling, the magnetization of Mn1.9Cr0.1Sb exhibits a first-order ferrimagnetic to antiferromagnetic transition at the exchange inversion temperature, TS = 261 K under a 0.1 T magnetic field. Our experimental results show that TS decreases with increasing magnetic field but increase with increasing hydrostatic pressure. The pressure induced transition is accompanied by a large positive baro-resistance of 30.5% for a hydrostatic pressure change of 0.69 GPa. These results show that the lattice parameters as well as the bond distance between Mn-Mn atoms play a crucial role in the magnetic and electronic transport properties of Mn1.9Cr0.1Sb. This sample also exhibits a large inverse magnetocaloric effect with a magnetic entropy change of ΔSm = +6.75 J/kg.K and negative magnetoresistance (44.5% for a field change of 5 T at TS in ambient pressure which may be useful for magnetic cooling and spintronics applications.

  4. The magnetic Curie temperature and exchange coupling between cations in tetragonal spinel oxide Mn{sub 2.5}M{sub 0.5}O{sub 4} (M = Co, Ni, Mn, Cr, and Mg) films

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, K.; Cheng, C. W.; Chern, G. [Physics Department and SPIN Research Center, National Chung Cheng University, Chia-Yi, Taiwan, 621 (China)

    2012-04-01

    Mn{sub 3}O{sub 4} is a Jahn-Taller tetragonal ferrite that has a relatively low Curie temperature (T{sub c}) of {approx}43 K due to weak coupling between the canting spins. In this study, we fabricated a series of 100-nm-thick Mn{sub 2.5}M{sub 0.5}O{sub 4} (M = Co, Ni, Mn, Cr, and Mg) films via oxygen-plasma-assisted molecular beam epitaxy and measured the structural and magnetic properties of these films. These films show single phase quality, and the c-axis lattice parameter of pure Mn{sub 3}O{sub 4} is 0.944 nm, with a c/a ratio {approx}1.16, consistent with the bulk values. The replacement of Mn by M (M = Co, Ni, Cr, and Mg) changes the lattice parameters, and the c/a ratio varies between 1.16 and 1.06 depending upon the cation distribution of the films. The magnetic Curie temperatures of these films also vary in the range of 25-66 K in that Ni and Co enhance the T{sub c} whereas Mg reduces the T{sub c} (Cr shows no effect on the T{sub c}). These changes to the T{sub c} are related to both the element electronic state and the cation distributions in these compounds. As a non-collinear spin configuration can induce electrical polarization, the present study provides a systematic way to enhance the magnetic transition temperature in tetragonal spinel ferrites.

  5. T2-weighted MRI-derived textural features reflect prostate cancer aggressiveness: preliminary results

    NARCIS (Netherlands)

    Nketiah, G.; Elschot, M.; Kim, E.; Teruel, J.R.; Scheenen, T.W.J.; Bathen, T.F.; Selnaes, K.M.

    2017-01-01

    PURPOSE: To evaluate the diagnostic relevance of T2-weighted (T2W) MRI-derived textural features relative to quantitative physiological parameters derived from diffusion-weighted (DW) and dynamic contrast-enhanced (DCE) MRI in Gleason score (GS) 3+4 and 4+3 prostate cancers. MATERIALS AND METHODS:

  6. Rapid synthesis of graphene/amorphous α-MnO2 composite with enhanced electrochemical performance for electrochemical capacitor

    International Nuclear Information System (INIS)

    Pang, Mingjun; Long, Guohui; Jiang, Shang; Ji, Yuan; Han, Wei; Wang, Biao; Liu, Xilong; Xi, Yunlong

    2015-01-01

    Highlights: • Graphene/MnO 2 is successfully fabricated by a facile co-precipitation method. • The graphene/MnO 2 electrode reaches 367 Fg −1 in 1 M KOH electrolyte. • The electrode exhibits good cycling performance of 73.9% retention after 1000 cycles. - Abstract: Nanostructured graphene/amorphous α-MnO 2 composites have been synthesized by a facile co-precipitation method under the alkaline condition, in which graphene nanosheets as a supporting substrate to grow MnO 2 . Characterizations of prepared samples’ morphology and microstructures indicate MnO 2 is successfully formed on the surface of graphene by electrostatic interaction. Moreover, the electrochemical properties of the synthesized electrode materials for supercapacitors are studied in a three-electrode experimental setup using a 1 M KOH aqueous solution as the electrolyte. As a result, the specific capacitance of graphene/MnO 2 composite (weight ratio of graphene to MnO 2 is 1:1) determined by a galvanostatic charge–discharge method at a current density of 1 Ag −1 reaches 367 Fg −1 , which is 1.8 and 4.6 fold higher than that of pure graphene and MnO 2 . The capacity retention of the graphene/MnO 2 composite is 73.9% of the original capacitance after 1000 cycles, indicating graphene/MnO 2 composite is a promising electrode material for supercapacitors

  7. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  8. An age estimation method using brain local features for T1-weighted images.

    Science.gov (United States)

    Kondo, Chihiro; Ito, Koichi; Kai Wu; Sato, Kazunori; Taki, Yasuyuki; Fukuda, Hiroshi; Aoki, Takafumi

    2015-08-01

    Previous statistical analysis studies using large-scale brain magnetic resonance (MR) image databases have examined that brain tissues have age-related morphological changes. This fact indicates that one can estimate the age of a subject from his/her brain MR image by evaluating morphological changes with healthy aging. This paper proposes an age estimation method using local features extracted from T1-weighted MR images. The brain local features are defined by volumes of brain tissues parcellated into local regions defined by the automated anatomical labeling atlas. The proposed method selects optimal local regions to improve the performance of age estimation. We evaluate performance of the proposed method using 1,146 T1-weighted images from a Japanese MR image database. We also discuss the medical implication of selected optimal local regions.

  9. XMCD study of the Ruddlesden-Popper phase La1.2Nd0.2Sr1.6Mn2O7

    International Nuclear Information System (INIS)

    Weigand, F.; Goering, E.; Geissler, J.; Justen, M.; Ruck, K.; Schuetz, G.; Doerr, K.

    2001-01-01

    X-ray Magnetic Circular Dichroism (XMCD) measurements of the Ruddlesden-Popper Phase La 1.2 Nd 0.2 Sr 1.6 Mn 2 O 7 are reported. The Mn K, La and Nd L 2 , 3 edges have been measured on a powder sample at two different magnetic fields at low temperature. The analysis of the spectra at B = 1T indicates a large orbital moment of the Nd 5d-states and a significant spin-polarization of the La 5d-band. Furthermore at the Mn Κ-edge a XMCD-signal is observed, showing a polarization of the Mn 4p-band. At lower field (0.2T) all XMCD-signals are about two times smaller corresponding to the lower total magnetization. The signal at the Nd L 2 edge vanishes completely at 0.2T. (au)

  10. Plasmon Enhancement of Photoinduced Resistivity Changes in Bi1-xCaxMnO3 Thin Films

    Science.gov (United States)

    Smolyaninova, Vera; Talanova, E.; Kolagani, Rajeswari; Yong, G.; Kennedy, R.; Steger, M.; Wall, K.

    2007-03-01

    Doped rare-earth manganese oxides (manganites) exhibit a wide variety of physical phenomena due to complex interplay of electronic, magnetic, orbital, and structural degrees of freedom and their sensitivity to external fields. A photoinduced insulator to conductor transition in charge-ordered manganites is especially interesting from the point of view of creating photonic devices. Thin films of Bi0.4Ca0.6MnO3 exhibit large photoinduced resistivity changes associated with melting of the charge ordering by visible light [1]. We have found a considerable increase of the photoinduced resistivity changes in the Bi0.4Ca0.6MnO3 thin film after depositing metal nanoparticles on the surface. This increase can be explained by enhancement of local electromagnetic field in the vicinity of the gold nanoparticle due to the plasmon resonance. The changes in lifetime of the photoinduced state will be reported, and the possible origin of these effects will be discussed. [1] V. N. Smolyaninova at al., Appl. Phys. Lett. 86, 071922 (2005).

  11. Magnetic properties and magnetocaloric effects in Mn1.2Fe0.8P1-xGex compounds

    International Nuclear Information System (INIS)

    Ou, Z Q; Wang, G F; Lin Song; Tegus, O; Brueck, E; Buschow, K H J

    2006-01-01

    We have studied the magnetic properties and magnetocaloric effects in the Mn 1.2 Fe 0.8 P 1-x Ge x compounds with x = 0.2, 0.22, 0.3, 0.4 and 0.5. X-ray diffraction patterns show that the Mn 1.2 Fe 0.8 P 1-x Ge x compounds crystallize in the hexagonal Fe 2 P-type crystal structure. The magnetic moments of the Mn 1.2 Fe 0.8 P 1-x Ge x compounds measured at 5 K and 5 T increase with increasing Ge content. The Curie temperature increases strongly and the magnetic entropy change has a maximum around 233 K for the compound with x = 0.22, which is about 19 and 31 J kg -1 K -1 for a field change of 2 and 5 T, respectively

  12. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, Shouwa-ku, 466-8550, Nagoya (Japan); Aoki, Ikuo [Medical System Company, Toshiba Corporation, Tokyo (Japan)

    2003-12-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 ) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in

  13. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Athyal, R. P.; Ismail, M.; Rudwan, M.; Khafajee, S.

    2009-01-01

    Full text: Tl-weighted fluid-attenuated inversion recovery (FLAIR) sequence is a relatively new pulse sequence for intracranial MR imaging. This study was performed to compare the image quality of Tl-weighted FLAIR with the Tl-weighted FSE sequence. Twenty patients with brain lesions underwent Tl-weighted fast spin-echo (FSE) and Tl-weighted FLAIR during the same imaging session. Four quantitative and three qualitative criteria were used to compare the two sequences after contrast. Two of four quantitative criteria pertained to lesion characteristics: lesion to white matter (WM) contrast-to-noise ratio (CNR) and lesion to cerebrospinal fluid (CSF) CNR, and two related to signals from normal tissue: grey matter to WM CNR and WM to CSF CNR. The three qualitative criteria were conspicuousness of the lesion, the presence of image artefacts and the overall image contrast. Both Tl-weighted FSE and FLAIR images were effective in demonstrating lesions. Image contrast was superior in Tl-weighted FLAIR images with significantly improved grey matter-WM CNRs and CSF-WM CNRs. The overall image contrast was judged to be superior on Tl-weighted FLAIR images compared with Tl-weighted FSE images by all neuroradiologists. Two of three reviewers considered that the FLAIR images had slightly increased imaging artefacts that, however, did not interfere with image interpretation. Tl-weighted FLAIR imaging provides improved lesion-to-background and grey to WM contrast-to-noise ratios. Superior conspicuity of lesions and overall image contrast is obtained in comparable acquisition times. These indicate an important role for Tl-weighted FLAIR in intracranial imaging and highlight its advantage over the more widely practiced Tl-weighted FSE sequence

  14. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI

    International Nuclear Information System (INIS)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P.; Zeman, F.; Teufel, A.; Lang, S.

    2015-01-01

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  15. T2-weighted images are superior to other MR image types for the determination of diffuse intrinsic pontine glioma intratumoral heterogeneity.

    Science.gov (United States)

    Harward, Stephen; Harrison Farber, S; Malinzak, Michael; Becher, Oren; Thompson, Eric M

    2018-03-01

    Diffuse intrinsic pontine glioma (DIPG) remains the main cause of death in children with brain tumors. Given the inefficacy of numerous peripherally delivered agents to treat DIPG, convection enhanced delivery (CED) of therapeutic agents is a promising treatment modality. The purpose of this study was to determine which MR imaging type provides the best discrimination of intratumoral heterogeneity to guide future stereotactic implantation of CED catheters into the most cellular tumor regions. Patients ages 18 years or younger with a diagnosis of DIPG from 2000 to 2015 were included. Radiographic heterogeneity index (HI) of the tumor was calculated by measuring the standard deviation of signal intensity of the tumor (SD Tumor ) normalized to the genu of the corpus callosum (SD Corpus Callosum ). Four MR image types (T2-weighted, contrast-enhanced T1-weighted, FLAIR, and ADC) were analyzed at several time points both before and after radiotherapy and chemotherapy. HI values across these MR image types were compared and correlated with patient survival. MR images from 18 patients with DIPG were evaluated. The mean survival ± standard deviation was 13.8 ± 13.7 months. T2-weighted images had the highest HI (mean ± SD, 5.1 ± 2.5) followed by contrast-enhanced T1-weighted images (3.7 ± 1.5), FLAIR images (3.0 ± 1.1), and ADC maps (1.6 ± 0.4). ANOVA demonstrated that HI values were significantly higher for T2-weighted images than FLAIR (p image HI values increased, while FLAIR and ADC HI values decreased. Univariate and multivariate analyses did not reveal a relationship between HI values and patient survival (p > 0.05). For children with DIPG, T2-weighted MRI demonstrates the greatest signal intensity variance suggesting tumor heterogeneity. Within this heterogeneity, T2-weighted signal hypointensity is known to correlate with increased cellularity and thus may represent a putative target for CED catheter placement in future clinical

  16. Utility of re-windowing for MR T2-weighted images in differentiating between benign tumors and cysts

    International Nuclear Information System (INIS)

    Yamamoto, A.; Nishikawa, K.; Otonari-Yamamoto, M.; Sano, T.

    2009-01-01

    Both benign tumors and cysts in the oral and maxillofacial region show clear borders and homogeneously high signal intensity on magnetic resonance (MR T2-weighted images, making differentiation difficult without contrast enhancement. Windowing for brightness and contrast adjustment may be helpful in interpreting relative signal intensities on MR images. This study was performed to determine whether re-windowing against targeted lesions on T2-weighted images was a useful procedure that would enhance differentiation without invasive contrast enhancement. Twenty-six lesions (13 benign tumors, 13 cysts) that showed clear borders and homogeneously high signal intensity on T2-weighted images were examined. The windowing parameters of axial images were readjusted to emphasize contrast only inside the lesions using automatic density adjustment. Re-windowed images were reviewed by three experienced oral radiologists and categorized based on the internal homogeneity of the lesion into four grades: 0, heterogeneous; 1, slightly heterogeneous; 2, slightly homogeneous; 3, homogeneous. Re-windowing was then evaluated for its usefulness in differentiating between benign tumors and cysts. For cysts, the rates of homogeneous (grades 3 and 2) and heterogeneous intensity (grades 1 and 0) were 66.7 (26/39) and 33.3% (13/39), respectively. For benign tumors, these rates were 33.3 (13/39) and 66.7% (26/39), respectively. Cysts showed a higher rate of homogeneous intensity, while the opposite was true for benign tumors. A significant difference in distribution was observed between cysts and benign tumors (P 2 test). Re-windowing for T2-weighted images is helpful in differentiating between benign tumors and cysts with clear borders and homogeneously high signal intensity on T2-weighted images. (author)

  17. Robust T1-weighted structural brain imaging and morphometry at 7T using MP2RAGE.

    Directory of Open Access Journals (Sweden)

    Kieran R O'Brien

    Full Text Available PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0 ± 4.1 years; 6 Male, who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004. In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004 from an average volumetric difference across structures of ≈ 6.6% to ≈ 2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.

  18. Three-dimensional isotropic T2-weighted cervical MRI at 3 T: Comparison with two-dimensional T2-weighted sequences

    International Nuclear Information System (INIS)

    Kwon, J.W.; Yoon, Y.C.; Choi, S.-H.

    2012-01-01

    Aim: To compare three-dimensional (3D) isotropic T2-weighted magnetic resonance imaging (MRI) sequences and reformation with two-dimensional (2D) T2-weighted sequences regarding image quality of the cervical spine at 3 T. Materials and methods: A phantom study was performed using a water-filled cylinder. The signal-to-noise and image homogeneity were evaluated. Fourteen (n = 14) volunteers were examined at 3 T using 3D isotropic T2-weighted sagittal and conventional 2D T2-weighted sagittal, axial, and oblique sagittal MRI. Multiplanar reformation (MPR) of the 3D T2-weighted sagittal dataset was performed simultaneously with image evaluation. In addition to artefact assessment, the visibility of anatomical structures in the 3D and 2D sequences was qualitatively assessed by two radiologists independently. Cohen’s kappa and Wilcoxon signed rank test were used for the statistical analysis. Result: The 3D isotropic T2-weighted sequence resulted in the highest signal-to-noise ratio (SNR) and lowest non-uniformity (NU) among the sequences in the phantom study. Quantitative evaluation revealed lower NU values of the cerebrospinal fluid (CSF) and muscles in 2D T2-weighted sagittal sequences compared to the 3D volume isotropic turbo spin-echo acquisition (VISTA) sequence. The other NU values revealed no statistically significant difference between the 2D turbo spin-echo (TSE) and 3D VISTA sequences (0.059 < p < 0.959). 3D VISTA images showed significantly fewer CSF flow artefacts (p < 0.001) and better delineated intradural nerve rootlets (p = 0.001) and neural foramina (p = 0.016) compared to 2D sequences. Conclusion: A 3D T2 weighted sequence is superior to conventional 2D sequences for the delineation of intradural nerve rootlets and neural foramina and is less affected by CSF flow artefacts.

  19. Magnetocaloric effects in Mn1.35Fe0.65P1−xSix compounds

    International Nuclear Information System (INIS)

    Geng Yao-Xiang; Tegus O; Bi Li-Ge

    2012-01-01

    The structural and magnetocaloric properties of Mn 1.35 Fe 0.65 P 1−x Si x compounds are investigated. The Si-substituted compounds, Mn 1.35 Fe 0.65 P 1−x Si x with x = 0.52, 0.54, 0.55, 0.56, and 0.57, are prepared by high-energy ball milling and the solid-state reaction. The X-ray diffraction shows that the compounds crystallize into the Fe 2 P-type hexagonal structure with space group P6-bar2m. The magnetic measurements show that the Curie temperature of the compound increases from 253 K for x = 0.52 to 296 K for x = 0.56. The isothermal magnetic-entropy change of the Mn 1.35 Fe 0.65 P 1−x Si x compound decreases with the Si content increasing. The maximal value of the magnetic-entropy change is about 7.0 J/kg·K in the Mn 1.35 Fe 0.65 P 0.48 Si 0.52 compound with a field change of 1.5 T. The compound quenched in water possesses a larger magnetic entropy change and a smaller thermal hysteresis than the non-quenched samples. The thermal hysteresis of the compound is less than 3.5 K. The maximum adiabatic temperature change is about 1.4 K in the Mn 1.35 Fe 0.65 P 0.45 Si 0.55 compound with a field change of 1.48 T. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  20. Magnetocaloric effects in MnFeP1-x As x -based compounds

    International Nuclear Information System (INIS)

    Brueck, E.; Ilyn, M.; Tishin, A.M.; Tegus, O.

    2005-01-01

    Here we present the results of an investigation of some magnetic and thermal properties of the compounds MnFeP 0.45 As 0.55 , MnFeP 0.47 As 0.53 , and Mn 1.1 Fe 0.9 P 0.47 As 0.53 which can be regarded as possible magnetic refrigerants for room temperature applications. Magnetization measurements are performed in the temperature range 250-330 K, in magnetic fields up to 5 T. The coexistence of the magnetic and structural first-order phase transitions is revealed in all three samples, suggesting its key role in the large values observed for the magnetocaloric effect. The adiabatic temperature change measured directly was up to 4.0, 3.4, and 4.2 K for a magnetic field change of 1.45 T

  1. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    International Nuclear Information System (INIS)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon

    1997-01-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change

  2. MRI findings of sacroiliitis in ankylosing spondylitis: roles of MPGR and delayed post-contrast T1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Eui Yong; Joo, Kyung Bin; Koo, Ja Hong; Moon, Won Jin; Hahm, Chang Kok; Kim, Tae Hwan; Kim, Seong Yoon [Hanyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    For early diagnosis of sacroiliitis in spondyloarthropathy, the MRI findings of sacroiliitis, roles of MPGR(multiplanar Gradient Recalled Acquisition in Steady State), and delayed post-contrast T1-weighted images were evaluated. Twenty six patients with seronegative spondyloarthropathy(Probable clinical diagnosis of ankylosing spondylitis) were grouped as either less than radiographic grade 1(group A) or more than grade 2(group B). The MRI findings of both sacroiliac joints were evaluated in every patient, and predominant sites were determined. The two groups were then compared. In 17 patients, the number of enhancing panni seen on early and delayed post-contrast T1-weighted images was counted and compared between the two groups. Panni were found in all cases, and in both groups, predominant patterns of involvement were the lower and iliac aspects of the sacroiliac joints in both groups; in group A, the synovial joints and punctate pannus were predominantly involved, and in group B, the ligamentous joints as well as the synovial joints and linear pannus. In group B, More periarticular fat accumulation than periarticular osteitis was found. For the evaluation of changes in joint space, MPGR images were superior to spin echo images. For the delineation of enhancing pannus less than radiographic grade I, delayed post-contrast images were statistically superior to those which were early post-contrast. MRI can detect early sacroiliitic change according to the predominant sites of involvement, and deslyed post-contrast images play a role in the diagnosis of early sacroiliitis. MPGR imaging is good for the evaluation of joint space change.

  3. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Science.gov (United States)

    Gong, Feilong; Lu, Shuang; Peng, Lifang; Zhou, Jing; Kong, Jinming; Jia, Dianzeng; Li, Feng

    2017-01-01

    Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC) show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D) hierarchical structure in-situ coated with carbon. PMID:29168756

  4. Hierarchical Mn2O3 Microspheres In-Situ Coated with Carbon for Supercapacitors with Highly Enhanced Performances

    Directory of Open Access Journals (Sweden)

    Feilong Gong

    2017-11-01

    Full Text Available Porous Mn2O3 microspheres have been synthesized and in-situ coated with amorphous carbon to form hierarchical C@Mn2O3 microspheres by first producing MnCO3 microspheres in solvothermal reactions, and then annealing at 500 °C. The self-assembly growth of MnCO3 microspheres can generate hollow structures inside each of the particles, which can act as micro-reservoirs to store biomass-glycerol for generating amorphous carbon onto the surfaces of Mn2O3 nanorods consisting of microspheres. The C@Mn2O3 microspheres, prepared at 500 °C, exhibit highly enhanced pseudocapacitive performances when compared to the particles after annealed at 400 °C and 600 °C. Specifically, the C@Mn2O3 microspheres prepared at 500 °C show high specific capacitances of 383.87 F g−1 at current density of 0.5 A g−1, and excellent cycling stability of 90.47% of its initial value after cycling for 5000 times. The asymmetric supercapacitors assembled with C@Mn2O3 microspheres after annealed at 500 °C and activated carbon (AC show an energy density of up to 77.8 Wh kg−1 at power density of 500.00 W kg−1, and a maximum power density of 20.14 kW kg−1 at energy density of 46.8 Wh kg−1. We can attribute the enhanced electrochemical performances of the materials to their three-dimensional (3D hierarchical structure in-situ coated with carbon.

  5. Magnetic properties of nanocrystalline La1-xMnO3+δ manganites: size effects

    International Nuclear Information System (INIS)

    Markovich, V; Fita, I; Mogilyansky, D; Wisniewski, A; Puzniak, R; Titelman, L; Vradman, L; Herskowitz, M; Gorodetsky, G

    2007-01-01

    The magnetic properties of nanocrystalline manganites La 1-x MnO 3+δ with particle size of 20 (LMO20), 25 (LMO25), and 30 nm (LMO30), prepared by the citrate method, have been investigated in the temperature range 5-320 K, magnetic field up to 90 kOe and under quasi-hydrostatic pressures up to 14.5 kbar. The studies involve sequential zero-field-cooled magnetization (M) measurements followed by magnetization measurements during cooling in the same magnetic field (H) and complementary measurements of ac susceptibility. Additional measurements of M versus H were carried out at ambient and applied pressures. All nanoparticles exhibit a paramagnetic to ferromagnetic transition (PFT) at a Curie temperature T C >200 K. It was found that the relative volume of the ferromagnetic phase increases for larger particle size and approaches a value of about 93% for LMO30. The real part of the ac susceptibility of sample LMO20 exhibits strong frequency dependence in a wide temperature range below T C , whereas for sample LMO30 only relatively weak frequency dependence was observed. The magnetization of sample LMO30 exhibits a PFT of second order; the type of transition could not be established for the smaller particles. It was found that an applied pressure enhances the T C of La 1-x MnO 3+δ nanoparticles with a pressure coefficient of dT C /dP∼1.9 K kbar -1 for LMO20 and dT C /dP∼1.4 K kbar -1 for LMO25 and LMO30 samples. Peculiar magnetic memory effects observed for sample LMO20 are discussed

  6. Evaluation of articular cartilage degeneration with contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Fujioka, Mikihiro

    1994-01-01

    The evaluation of glycosaminoglycan (GAG) concentration is important in the clinical diagnosis of articular cartilage degeneration. Glycosaminoglycan provides a large number of fixed negative charges. When manganese ion (Mn 2+ ) is administered to the cartilage matrix, this cation diffuses into the matrix and accumulates in accordance with the distribution of fixed negative charges owing to the electrostatic interaction. The accumulation of Mn 2+ causes a shortening of the relaxation times, resulting in high signal intensity in the MR image, when a T 1 -weighted image is obtained. The present study applied this new method to the articular cartilage to evaluate the degree of the cartilage degeneration. Small pieces of articular cartilage were dissected from the knee joints of young chickens. Experimentally degenerated articular cartilage was obtained by treating the specimen with various concentrations of papain solution. Then specimens were soaked in manganese solution until they obtained equilibrium and served for MR microimaging. The fixed charge density (FCD), the concentration of Mn 2+ and Na + , T 1 and T 2 relaxation times were also measured. In degenerated cartilage, lower accumulation of Mn 2+ due to lower GAG density caused a lower than normal signal intensity. Thus, administration of Mn 2+ enhances the biochemical change in the cartilage matrix in terms of differences in the relaxation time. The actual signal intensity on MRI of each specimen corresponded to the theoretical signal intensity, which was calculated from the FCD. It was concluded that MR images taken with contrast enhancement by Mn 2+ give direct visual information about the GAG density in the articular cartilage. MRI with cationic contrast agent could develop into a new method for early non-invasive diagnosis of cartilage dysfunction and degeneration. (author)

  7. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  8. All-Polymer Solar Cell Performance Optimized via Systematic Molecular Weight Tuning of Both Donor and Acceptor Polymers.

    Science.gov (United States)

    Zhou, Nanjia; Dudnik, Alexander S; Li, Ting I N G; Manley, Eric F; Aldrich, Thomas J; Guo, Peijun; Liao, Hsueh-Chung; Chen, Zhihua; Chen, Lin X; Chang, Robert P H; Facchetti, Antonio; Olvera de la Cruz, Monica; Marks, Tobin J

    2016-02-03

    The influence of the number-average molecular weight (Mn) on the blend film morphology and photovoltaic performance of all-polymer solar cells (APSCs) fabricated with the donor polymer poly[5-(2-hexyldodecyl)-1,3-thieno[3,4-c]pyrrole-4,6-dione-alt-5,5-(2,5-bis(3-dodecylthiophen-2-yl)thiophene)] (PTPD3T) and acceptor polymer poly{[N,N'-bis(2-octyldodecyl)naphthalene-1,4,5,8-bis(dicarboximide)-2,6-diyl]-alt-5,5'-(2,2'-bithiophene)} (P(NDI2OD-T2); N2200) is systematically investigated. The Mn effect analysis of both PTPD3T and N2200 is enabled by implementing a polymerization strategy which produces conjugated polymers with tunable Mns. Experimental and coarse-grain modeling results reveal that systematic Mn variation greatly influences both intrachain and interchain interactions and ultimately the degree of phase separation and morphology evolution. Specifically, increasing Mn for both polymers shrinks blend film domain sizes and enhances donor-acceptor polymer-polymer interfacial areas, affording increased short-circuit current densities (Jsc). However, the greater disorder and intermixed feature proliferation accompanying increasing Mn promotes charge carrier recombination, reducing cell fill factors (FF). The optimized photoactive layers exhibit well-balanced exciton dissociation and charge transport characteristics, ultimately providing solar cells with a 2-fold PCE enhancement versus devices with nonoptimal Mns. Overall, it is shown that proper and precise tuning of both donor and acceptor polymer Mns is critical for optimizing APSC performance. In contrast to reports where maximum power conversion efficiencies (PCEs) are achieved for the highest Mns, the present two-dimensional Mn optimization matrix strategy locates a PCE "sweet spot" at intermediate Mns of both donor and acceptor polymers. This study provides synthetic methodologies to predictably access conjugated polymers with desired Mn and highlights the importance of optimizing Mn for both polymer

  9. 4T1 Murine Mammary Carcinoma Cells Enhance Macrophage-Mediated Innate Inflammatory Responses.

    Directory of Open Access Journals (Sweden)

    Laurence Madera

    Full Text Available Tumor progression and the immune response are intricately linked. While it is known that cancers alter macrophage inflammatory responses to promote tumor progression, little is known regarding how cancers affect macrophage-dependent innate host defense. In this study, murine bone-marrow-derived macrophages (BMDM were exposed to murine carcinoma-conditioned media prior to assessment of the macrophage inflammatory response. BMDMs exposed to 4T1 mammary carcinoma-conditioned medium demonstrated enhanced production of pro-inflammatory cytokines tumor necrosis factor α, interleukin-6, and CCL2 in response to lipopolysaccharide (LPS while production of interleukin-10 remained unchanged. The increased LPS-induced production of pro-inflammatory cytokines was transient and correlated with enhanced cytokine production in response to other Toll-like receptor agonists, including peptidoglycan and flagellin. In addition, 4T1-conditioned BMDMs exhibited strengthened LPS-induced nitric oxide production and enhanced phagocytosis of Escherichia coli. 4T1-mediated augmentation of macrophage responses to LPS was partially dependent on the NFκB pathway, macrophage-colony stimulating factor, and actin polymerization, as well as the presence of 4T1-secreted extracellular vesicles. Furthermore, peritoneal macrophages obtained from 4T1 tumor-bearing mice displayed enhanced pro-inflammatory cytokine production in response to LPS. These results suggest that uptake of 4T1-secreted factors and actin-mediated ingestion of 4T1-secreted exosomes by macrophages cause a transient enhancement of innate inflammatory responses. Mammary carcinoma-mediated regulation of innate immunity may have significant implications for our understanding of host defense and cancer progression.

  10. Microwave-assisted synthesis of high-voltage nanostructured LiMn1.5Ni0.5O4 spinel: tuning the Mn3+ content and electrochemical performance

    CSIR Research Space (South Africa)

    Jafta, CJ

    2013-08-01

    Full Text Available on the Mn3+ concentration and electrochemistry of the LiMn1.5Ni0.5O4 spinel. It is shown that microwave is capable of tuning the Mn3+ content of the spinel for enhanced electrochemical performance (high capacity, high capacity retention, excellent rate...

  11. Hydrothermal synthesis of novel Mn3O4 nano-octahedrons with enhanced supercapacitors performances

    Science.gov (United States)

    Jiang, Hao; Zhao, Ting; Yan, Chaoyi; Ma, Jan; Li, Chunzhong

    2010-10-01

    Uniform and single-crystalline Mn3O4 nano-octahedrons have been successfully synthesized by a simple ethylenediaminetetraacetic acid disodium salt (EDTA-2Na) assisted hydrothermal route. The octahedron structures exhibit a high geometric symmetry with smooth surfaces and the mean side length of square base of octahedrons is ~160 nm. The structure is reckoned to provide superior functional properties and the nano-size achieved in the present work is noted to further facilitate the material property enhancement. The formation process was proposed to begin with a ``dissolution-recrystallization'' which is followed by an ``Ostwald ripening'' mechanism. The Mn3O4 nano-octahedrons exhibited an enhanced specific capacitance of 322 F g-1 compared with the truncated octahedrons with specific capacitances of 244 F g-1, making them a promising electrode material for supercapacitors.Uniform and single-crystalline Mn3O4 nano-octahedrons have been successfully synthesized by a simple ethylenediaminetetraacetic acid disodium salt (EDTA-2Na) assisted hydrothermal route. The octahedron structures exhibit a high geometric symmetry with smooth surfaces and the mean side length of square base of octahedrons is ~160 nm. The structure is reckoned to provide superior functional properties and the nano-size achieved in the present work is noted to further facilitate the material property enhancement. The formation process was proposed to begin with a ``dissolution-recrystallization'' which is followed by an ``Ostwald ripening'' mechanism. The Mn3O4 nano-octahedrons exhibited an enhanced specific capacitance of 322 F g-1 compared with the truncated octahedrons with specific capacitances of 244 F g-1, making them a promising electrode material for supercapacitors. Electronic supplementary information (ESI) available: TEM images; EDTA-2Na reaction details. See DOI: 10.1039/c0nr00257g

  12. Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury.

    Science.gov (United States)

    Srichai, Monvadi B; Lim, Ruth P; Lath, Narayan; Babb, James; Axel, Leon; Kim, Daniel

    2013-01-01

    We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury. Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse. A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence. Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.

  13. Pressure-induced spin and charge transport in La1.25Sr1.75Mn2O7 single crystal

    International Nuclear Information System (INIS)

    Mydeen, K.; Arumugam, S.; Prabhakaran, D.; Yu, R.C.; Jin, C.Q.

    2009-01-01

    We investigated the effect of uniaxial and hydrostatic pressure on resistivity and ac-magnetic susceptibility of two-dimensional layered manganite, La 1.25 Sr 1.75 Mn 2 O 7 (LSMO125) to investigate the lattice effect on magnetic and electronic properties. Asymmetric role of uniaxial pressure, || and -perpendicular to c-axis on the spin flop and charge transport has been revealed while comparing hydrostatic pressure. Uniaxial pressure along c-axis increases metal-insulator transition temperature (T MI ) and ferromagnetic ordering temperature (T C ), whereas it decreases the resistivity along ab-plane (ρ ab ). In contrast to pressure along c-axis, T MI and T C decrease, whereas the resistivity along c-axis (ρ c ) increases with pressure || to ab-plane. ρ c /ρ ab is quite large, increasing with pressure and shows a peak at around T MI . Uniaxial pressure behaviour is strongly related to the Mn-O-Mn linkage between MnO 2 layers and the spin reorientation from the apical axis to the basal plane and vice versa with pressure. Both ρ ab and ρ c decrease whereas T MI and T C increases under hydrostatic pressure. Influence of spin and charge on magnetic and electrical properties under hydrostatic pressure are explained by pressure-induced cant between the MnO 2 bilayers and variation in bond lengths. The different pressure driving rates of T MI while measuring ρ ab and ρ c confirms that there is a strong competition between the in and out plane components under hydrostatic pressure

  14. Liver acquisition with acceleration volume acquisition gadolinium-enhanced magnetic resonance combined with T2 sequences in the diagnosis of local recurrence of rectal cancer.

    Science.gov (United States)

    Cao, Wuteng; Li, Fangqian; Gong, Jiaying; Liu, Dechao; Deng, Yanhong; Kang, Liang; Zhou, Zhiyang

    2016-11-22

    To investigate the efficacy of liver acquisition with acceleration volume acquisition (LAVA) gadolinium-enhanced magnetic resonance (MR) sequences and to assess its added accuracy in diagnosing local recurrence (LR) of rectal cancer with conventional T2-weighted fast spin echo (FSE) sequences. Pelvic MRI, including T2-weighted FSE sequences, gadolinium-enhanced sequences of LAVA and T1-weighted FSE with fat suppression, was performed on 225 patients with postoperative rectal cancer. Two readers evaluated the presence of LR according to "T2" (T2 sequences only), "T2 + LAVA-Gad" (LAVA and T2 imaging), and "T2 + T1-fs-Gad" (T1 fat suppression-enhanced sequence with T2 images). To evaluate diagnostic efficiency, imaging quality with LAVA and T1-fs-Gad by subjective scores and the signal intensity (SI) ratio. In the result, the SI ratio of LAVA was significantly higher than that of T1-fs-Gad (p = 0.0001). The diagnostic efficiency of "T2 + LAVA-Gad" was better than that of "T2 + T1-fs-Gad" (p = 0.0016 for Reader 1, p = 0.0001 for Reader 2) and T2 imaging only (p = 0.0001 for Reader 1; p = 0.0001 for Reader 2). Therefore, LAVA gadolinium-enhanced MR increases the accuracy of diagnosis of LR from rectal cancer and could replace conventional T1 gadolinium-enhanced sequences in the postoperative pelvic follow-up of rectal cancer.

  15. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  16. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  17. Magnetic properties of Tb1-xSmxMn2Si2 silicides

    International Nuclear Information System (INIS)

    Kilic, A.; Kervan, S.; Gencer, A.

    2005-01-01

    The structural and magnetic properties of polycrystalline Tb 1-x Sm x Mn 2 Si 2 (0= 2 Si 2 -type structure with the space group I4/mmm. Substitution of Sm for Tb leads to a linear increase of the lattice constants and the unit cell volume. The lattice constants and the unit cell volume obey Vegard's law. At low temperatures, the rare earth sublattice orders and reconfigures the ordering in the Mn sublattice. The Neel temperature T N (Mn) determined by DSC technique decreases linearly with increase in Sm content x. The results are collected in an x-T magnetic-phase diagram

  18. Diagnostic accuracy of automatic normalization of CBV in glioma grading using T1- weighted DCE-MRI.

    Science.gov (United States)

    Sahoo, Prativa; Gupta, Rakesh K; Gupta, Pradeep K; Awasthi, Ashish; Pandey, Chandra M; Gupta, Mudit; Patir, Rana; Vaishya, Sandeep; Ahlawat, Sunita; Saha, Indrajit

    2017-12-01

    Aim of this retrospective study was to compare diagnostic accuracy of proposed automatic normalization method to quantify the relative cerebral blood volume (rCBV) with existing contra-lateral region of interest (ROI) based CBV normalization method for glioma grading using T1-weighted dynamic contrast enhanced MRI (DCE-MRI). Sixty patients with histologically confirmed gliomas were included in this study retrospectively. CBV maps were generated using T1-weighted DCE-MRI and are normalized by contralateral ROI based method (rCBV_contra), unaffected white matter (rCBV_WM) and unaffected gray matter (rCBV_GM), the latter two of these were generated automatically. An expert radiologist with >10years of experience in DCE-MRI and a non-expert with one year experience were used independently to measure rCBVs. Cutoff values for glioma grading were decided from ROC analysis. Agreement of histology with rCBV_WM, rCBV_GM and rCBV_contra respectively was studied using Kappa statistics and intra-class correlation coefficient (ICC). The diagnostic accuracy of glioma grading using the measured rCBV_contra by expert radiologist was found to be high (sensitivity=1.00, specificity=0.96, pnormalization method showed same percentage of agreement for both expert and non-expert user. rCBV_WM showed an agreement of 88.33% (kappa=0.76,pnormalization of CBV using the proposed method could provide better diagnostic accuracy compared to the manual contralateral based approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Resonantly enhanced spin-lattice relaxation of Mn2 + ions in diluted magnetic (Zn,Mn)Se/(Zn,Be)Se quantum wells

    Science.gov (United States)

    Debus, J.; Ivanov, V. Yu.; Ryabchenko, S. M.; Yakovlev, D. R.; Maksimov, A. A.; Semenov, Yu. G.; Braukmann, D.; Rautert, J.; Löw, U.; Godlewski, M.; Waag, A.; Bayer, M.

    2016-05-01

    The dynamics of spin-lattice relaxation in the magnetic Mn2 + ion system of (Zn,Mn)Se/(Zn,Be)Se quantum-well structures are studied using optical methods. Pronounced cusps are found in the giant Zeeman shift of the quantum-well exciton photoluminescence at specific magnetic fields below 10 T, when the Mn spin system is heated by photogenerated carriers. The spin-lattice relaxation time of the Mn ions is resonantly accelerated at the cusp magnetic fields. Our theoretical analysis demonstrates that a cusp occurs at a spin-level mixing of single Mn2 + ions and a quick-relaxing cluster of nearest-neighbor Mn ions, which can be described as intrinsic cross-relaxation resonance within the Mn spin system.

  20. Structural, electrical and magnetic properties of Sb-doped Pr2/3Ba1/3MnO3 perovskite manganites

    International Nuclear Information System (INIS)

    Sen, Vikram; Panwar, Neeraj; Bhalla, G.L.; Agarwal, S.K.

    2007-01-01

    We report here the electrical, magnetic and micro-structural features of the Sb-doped (nominally at Mn-sites) Pr 2/3 Ba 1/3 MnO 3 perovskite manganites. Pristine material shows two insulator-metal (I-M) like transitions in the resistivity-temperature (ρ-T) behaviour. While the higher temperature transition (T P1 ) at ∼195 K is reminiscent of the usual metal-insulator transition, the lower temperature transition (T P2 ) at ∼160 K has been ascribed to the grain boundary (GB) effects arising out of the ionic size mismatch between the ions present at the rare-earth site (Pr and Ba). With Sb doping at the Mn-site, both the resistivity peaks are seen to shift to lower temperatures. Room temperature resistivity and the peak values are also successively increasing with Sb doping. Scanning electron micrographs of the samples indicate a gradual increase in their grain sizes with Sb which indicates a gradual decrease in the GB density. The higher temperature insulator-metal transition (T P1 ) shift is explained on the basis of a competition between double-exchange and super-exchange mechanisms. The observed overall resistivity increase and the shift in the resistivity hump (T P2 ) with Sb are found related to the gradually decreasing GB density and the ensuing lattice strain increase at the grain boundaries. The intrinsic MR gets suppressed and the extrinsic MR gets enhanced with Sb doping. The observed low temperature resistivity upturn related to the localization of carriers, is also seen to increase with Sb

  1. Comparison of dynamic contrast-enhanced MRI parameters of breast lesions at 1.5 and 3.0 T: a pilot study

    Science.gov (United States)

    Pineda, F D; Medved, M; Fan, X; Ivancevic, M K; Abe, H; Shimauchi, A; Newstead, G M

    2015-01-01

    Objective: To compare dynamic contrast-enhanced (DCE) MRI parameters from scans of breast lesions at 1.5 and 3.0 T. Methods: 11 patients underwent paired MRI examinations in both Philips 1.5 and 3.0 T systems (Best, Netherlands) using a standard clinical fat-suppressed, T1 weighted DCE-MRI protocol, with 70–76 s temporal resolution. Signal intensity vs time curves were fit with an empirical mathematical model to obtain semi-quantitative measures of uptake and washout rates as well as time-to-peak enhancement (TTP). Maximum percent enhancement and signal enhancement ratio (SER) were also measured for each lesion. Percent differences between parameters measured at the two field strengths were compared. Results: TTP and SER parameters measured at 1.5 and 3.0 T were similar; with mean absolute differences of 19% and 22%, respectively. Maximum percent signal enhancement was significantly higher at 3 T than at 1.5 T (p = 0.006). Qualitative assessment showed that image quality was significantly higher at 3 T (p = 0.005). Conclusion: Our results suggest that TTP and SER are more robust to field strength change than other measured kinetic parameters, and therefore measurements of these parameters can be more easily standardized than measurements of other parameters derived from DCE-MRI. Semi-quantitative measures of overall kinetic curve shape showed higher reproducibility than do discrete classification of kinetic curve early and delayed phases in a majority of the cases studied. Advances in knowledge: Qualitative measures of curve shape are not consistent across field strength even when acquisition parameters are standardized. Quantitative measures of overall kinetic curve shape, by contrast, have higher reproducibility. PMID:25785918

  2. Large enhancement of Blocking temperature by control of interfacial structures in Pt/NiFe/IrMn/MgO/Pt multilayers

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2015-09-01

    Full Text Available The Blocking temperature (TB of Pt/NiFe/IrMn/MgO/Pt multilayers was greatly enhanced from far below room temperature (RT to above RT by inserting 1 nm thick Mg layer at IrMn/MgO interface. Furthermore, the exchange bias field (Heb was increased as well by the control of interfacial structures. The evidence for a significant fraction of Mn-O bonding at IrMn/MgO interface without Mg insertion layer was provided by X-ray photoelectron spectroscopy. The bonding between Mn and O can decrease the antiferromagnetism of IrMn film, leading to lower value of TB in Pt/NiFe/IrMn/MgO/Pt multilayers. Ultrathin Mg film inserted at IrMn/MgO interface acting as an oxygen sinking layer can suppress the oxidation reactions between Mn and O and reduce the formation of Mn-O bonding greatly. The oxidation suppression results in the recovery of the antiferromagnetism of IrMn film, which can enhance TB and Heb. Furthermore, the high resolution transmission electron microscopy demonstrates that the Mg insertion layer can efficiently promote a high-quality MgO (200 texture. This study will enhance the understanding of physics in antiferromagnet-based spintronic devices.

  3. Rapid synthesis of graphene/amorphous α-MnO{sub 2} composite with enhanced electrochemical performance for electrochemical capacitor

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Mingjun [Key Laboratory of Physics and Technology for Advanced Batteries, Ministry of Education, College of Physics, Jilin University, Jiefang Road 2519, Changchun 130012 (China); Long, Guohui [College of Life Sciences, Jilin Agricultural University, Changchun 130118 (China); Jiang, Shang [State Key Laboratory of Inorganic Synthesis and Preparative Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China); Ji, Yuan, E-mail: jiyuan@jlu.edu.cn [Key Laboratory of Physics and Technology for Advanced Batteries, Ministry of Education, College of Physics, Jilin University, Jiefang Road 2519, Changchun 130012 (China); Han, Wei [Key Laboratory of Physics and Technology for Advanced Batteries, Ministry of Education, College of Physics, Jilin University, Jiefang Road 2519, Changchun 130012 (China); Wang, Biao [Key Laboratory of Physics and Technology for Advanced Batteries, Ministry of Education, College of Physics, Jilin University, Jiefang Road 2519, Changchun 130012 (China); School of Science, University of Science and Technology Liaoning, Anshan 114051 (China); Liu, Xilong; Xi, Yunlong [Key Laboratory of Physics and Technology for Advanced Batteries, Ministry of Education, College of Physics, Jilin University, Jiefang Road 2519, Changchun 130012 (China)

    2015-04-15

    Highlights: • Graphene/MnO{sub 2} is successfully fabricated by a facile co-precipitation method. • The graphene/MnO{sub 2} electrode reaches 367 Fg{sup −1} in 1 M KOH electrolyte. • The electrode exhibits good cycling performance of 73.9% retention after 1000 cycles. - Abstract: Nanostructured graphene/amorphous α-MnO{sub 2} composites have been synthesized by a facile co-precipitation method under the alkaline condition, in which graphene nanosheets as a supporting substrate to grow MnO{sub 2}. Characterizations of prepared samples’ morphology and microstructures indicate MnO{sub 2} is successfully formed on the surface of graphene by electrostatic interaction. Moreover, the electrochemical properties of the synthesized electrode materials for supercapacitors are studied in a three-electrode experimental setup using a 1 M KOH aqueous solution as the electrolyte. As a result, the specific capacitance of graphene/MnO{sub 2} composite (weight ratio of graphene to MnO{sub 2} is 1:1) determined by a galvanostatic charge–discharge method at a current density of 1 Ag{sup −1} reaches 367 Fg{sup −1}, which is 1.8 and 4.6 fold higher than that of pure graphene and MnO{sub 2}. The capacity retention of the graphene/MnO{sub 2} composite is 73.9% of the original capacitance after 1000 cycles, indicating graphene/MnO{sub 2} composite is a promising electrode material for supercapacitors.

  4. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.

    Science.gov (United States)

    Yoon, Jeong Hee; Yu, Mi Hye; Chang, Won; Park, Jin-Young; Nickel, Marcel Dominik; Son, Yohan; Kiefer, Berthold; Lee, Jeong Min

    2017-10-01

    The purpose of the study was to investigate the clinical feasibility of free-breathing dynamic T1-weighted imaging (T1WI) using Cartesian sampling, compressed sensing, and iterative reconstruction in gadoxetic acid-enhanced liver magnetic resonance imaging (MRI). This retrospective study was approved by our institutional review board, and the requirement for informed consent was waived. A total of 51 patients at high risk of breath-holding failure underwent dynamic T1WI in a free-breathing manner using volumetric interpolated breath-hold (BH) examination with compressed sensing reconstruction (CS-VIBE) and hard gating. Timing, motion artifacts, and image quality were evaluated by 4 radiologists on a 4-point scale. For patients with low image quality scores (XD]) reconstruction was additionally performed and reviewed in the same manner. In addition, in 68.6% (35/51) patients who had previously undergone liver MRI, image quality and motion artifacts on dynamic phases using CS-VIBE were compared with previous BH-T1WIs. In all patients, adequate arterial-phase timing was obtained at least once. Overall image quality of free-breathing T1WI was 3.30 ± 0.59 on precontrast and 2.68 ± 0.70, 2.93 ± 0.65, and 3.30 ± 0.49 on early arterial, late arterial, and portal venous phases, respectively. In 13 patients with lower than average image quality (XD-reconstructed CS-VIBE) significantly reduced motion artifacts (P XD reconstruction showed less motion artifacts and better image quality on precontrast, arterial, and portal venous phases (P < 0.0001-0.013). Volumetric interpolated breath-hold examination with compressed sensing has the potential to provide consistent, motion-corrected free-breathing dynamic T1WI for liver MRI in patients at high risk of breath-holding failure.

  5. Characteristic signal changes in the pontine base on T2- and multishot diffusion-weighted images in spinocerebellar ataxia type 1

    International Nuclear Information System (INIS)

    Adachi, M.; Kawanami, T.; Ohshima, H.; Hosoya, T.

    2006-01-01

    The aim of the present study was to demonstrate characteristic signal changes of the pontine base on T2-weighted images of patients with SCA 1, and to elucidate the relationship between abnormal high-intensities of the pontine base on T2-weighted images and the findings on multishot diffusion-weighted images. We assessed abnormal signals of the pontine base on T2-weighted images from 50 controls and six patients with SCA 1 diagnosed by genetic analysis. At the same time, we evaluated the degeneration of the transverse pontine fibers in the pontine base by multishot diffusion-weighted imaging. A midline high-intensity was seen in the pontine base on T2-weighted images in two of the 50 controls and five of the six patients with SCA 1. The midline high-intensity had a sensitivity of 83.3% for patients and a specificity of 96.0% for controls. Multishot diffusion-weighted imaging demonstrated the degeneration - the amorphous-pattern signal - of the transverse pontine fibers in four (66.7%) of the six patients. In the other two patients, the zebra-pattern signal was seen in the pontine base. The midline high-intensity on T2-weighted images appears to be one of characteristic MRI findings of SCA 1. Multishot diffusion-weighted imaging suggested that the midline high-intensity should reflect the degeneration of the transverse pontine fibers. (orig.)

  6. Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T

    International Nuclear Information System (INIS)

    Rechichi, Gilda; Sironi, Sandro; Galimberti, Stefania; Valsecchi, Maria Grazia; Signorelli, Mauro; Perego, Patrizia

    2010-01-01

    To determine the diagnostic accuracy of diffusion-weighted (DW) magnetic resonance (MR) imaging in the preoperative assessment of myometrial invasion by endometrial cancer. In this prospective study, 47 patients with histologically confirmed endometrial cancer underwent preoperative MR imaging and total hysterectomy. The MR protocol included spin-echo multishot T2-weighted, dynamic T1-weighted and DW images acquired with b-values of 0 and 500 s/mm 2 . Myometrial tumour spread was classified as superficial (<50%) or deep (≥50% myometrial thickness). Postoperative histopathological findings served as a reference standard. Indices of diagnostic performance were assessed for each sequence. At histopathological examination, superficial myometrial invasion was found in 34 patients and deep myometrial invasion in 13. In the assessment of tumour invasion, sensitivity, specificity, positive and negative predictive values of T2-weighted images were 92.3%, 76.5%, 60.0% and 96.3%, respectively. The corresponding values for dynamic images were 69.2%, 61.8%, 40.9% and 84.0%, and for DW images 84.6%, 70.6%, 52.4% and 92.3%. T2-weighted and DW imaging proved to be the most accurate techniques for tumour spread determination. DW imaging proved to be accurate in assessing myometrial invasion, and it could replace dynamic imaging as an adjunct to routine T2-weighted imaging for preoperative evaluation of endometrial cancer. (orig.)

  7. Small polaron hopping conduction in samples of ceramic La1.4Sr1.6Mn2O7.06

    International Nuclear Information System (INIS)

    Nakatsugawa, H.; Iguchi, E.; Jung, W.H.; Munakata, F.

    1999-01-01

    The ceramic sample of La 1.4 Sr 1.6 Mn 2 O 7.06 exhibits the metal-insulator transition and a negative magnetoresistance in the vicinity of the Curie temperature (T C ∼ 100 K). The dc magnetic susceptibility between 100 K and 280 K is nearly constant and decreases gradually with increasing temperature above 280 K. The measurements of dc resistivity and the thermoelectric power indicate that small polaron hopping conduction takes place at T > 280 K. The spin ordering due to the two-dimensional d x 2 -y 2 state occurring at T > 280 K is directly related to the hopping conduction above 280 K, although the spin ordering due to the one-dimensional d 3z 2 -r 2 state takes place at T > T C . The two-dimensional d x 2 -y 2 state extending within the MnO 2 sheets starts to narrow and leads to the carrier localisation at 280 K. The effective number of holes in this sample estimated from the thermoelectric power is considerably smaller than the nominal value. This indicates that the small polaron hopping conduction takes place predominantly within the in-plane MnO 2 sheets. A discussion is given of the experimental results of the ceramic sample of La 2/3 Ca 1/3 MnO 2.98 . Copyright (1999) CSIRO Australia

  8. Enhanced Cycleability of Amorphous MnO₂ by Covering on α-MnO₂ Needles in an Electrochemical Capacitor.

    Science.gov (United States)

    Liu, Quanbing; Ji, Shan; Yang, Juan; Wang, Hui; Pollet, Bruno G; Wang, Rongfang

    2017-08-24

    An allomorph MnO₂@MnO₂ core-shell nanostructure was developed via a two-step aqueous reaction method. The data analysis of Scanning Electron Microscopy, Transmission Electron Microscopy, X-Ray Diffraction and N₂ adsorption-desorption isotherms experiments indicated that this unique architecture consisted of a porous layer of amorphous-MnO₂ nano-sheets which were well grown onto the surface of α-MnO₂ nano-needles. Cyclic voltammetry experiments revealed that the double-layer charging and Faradaic pseudo -capacity of the MnO₂@MnO₂ capacitor electrode contributed to a specific capacitance of 150.3 F·g -1 at a current density of 0.1 A·g -1 . Long cycle life experiments on the as-prepared MnO₂@MnO₂ sample showed nearly a 99.3% retention after 5000 cycles at a current density of 2 A·g -1 . This retention value was found to be significantly higher than those reported for amorphous MnO₂-based capacitor electrodes. It was also found that the remarkable cycleability of the MnO₂@MnO₂ was due to the supporting role of α-MnO₂ nano-needle core and the outer amorphous MnO₂ layer.

  9. Folate conjugated Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles for targeted magnetic resonance imaging in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xinyi [The Education Ministry Key Lab of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Normal University, Shanghai 200234 (China); Zhou, Zhiguo, E-mail: zgzhou@shnu.edu.cn [The Education Ministry Key Lab of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Normal University, Shanghai 200234 (China); Wang, Li; Tang, Caizhi; Yang, Hong [The Education Ministry Key Lab of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Normal University, Shanghai 200234 (China); Yang, Shiping, E-mail: shipingy@shnu.edu.cn [The Education Ministry Key Lab of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials, Shanghai Normal University, Shanghai 200234 (China); The Education Ministry Key Lab of Pesticide and Chemical Biology, South China Agricultural University, Guangzhou 510641 (China)

    2014-09-15

    Graphical abstract: The Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA has been used as a T{sub 1}-MRI probe for in vivo. - Highlights: • The PEG and FA modified Mn{sub 3}O{sub 4}@SiO{sub 2} nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2}–FA) were prepared. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA exhibited the good colloidal stability in the simulated biological medium. • Mn{sub 3}O{sub 4}@SiO{sub 2}–FA showed the targeting ability to HeLa cells overexpressed the FA receptor. • The T{sub 1}-weighted magnetic resonance (MR) imaging demonstrated the targeting ability of Mn{sub 3}O{sub 4}@SiO{sub 2}–FA in vivo tumor. - Abstract: The monodisperse silica-coated manganese oxide nanoparticles (Mn{sub 3}O{sub 4}@SiO{sub 2} NPs) were synthesized via the high temperature pyrolysis approach and were aminated through silanization. The amine-functionalized Mn{sub 3}O{sub 4} NPs enabled the covalent conjugation of hydrophilic methoxypoly(ethylene glycol) (PEG) and the targeting ligand of folate (FA) onto their surface. The formed PEG and FA modified Mn{sub 3}O{sub 4} NPs (Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA) exhibited the good colloidal stability in the simulated biological medium and the targeting ability to HeLa cells overexpressed the FA receptor. The T{sub 1}-weighted magnetic resonance (MR) imaging and inductively coupled plasma atomic emission spectroscopy (ICP-AES) analysis of Mn{sub 3}O{sub 4}@SiO{sub 2}(PEG)–FA NPs further demonstrated their targeting ability in tumor.

  10. Developmental patterns of fetal fat and corresponding signal on T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Blondiaux, Eleonore; Chougar, Lydia; Ducou le Pointe, Hubert; Garel, Catherine; Gelot, Antoinette; Valence, Stephanie; Audureau, Etienne; Jouannic, Jean-Marie; Dhombres, Ferdinand

    2018-01-01

    Evaluation of subcutaneous fetal fat layer thickness on T1-weighted sequences can be used to predict birth weight. Little is known about normal MR signal patterns of subcutaneous tissue throughout pregnancy. To establish developmental patterns of subcutaneous fetal fat signal on T1-weighted sequences during the 2nd and 3rd trimesters. We retrospectively examined T1-weighted images of 110 fetal MRI scans. We measured signal intensity of subcutaneous fat on thighs, buttocks, trunk, nuchal region, chin and scalp. We then calculated the ratios of the obtained values with fetal muscle, amnios and maternal fat signal, and compared the results with those of immunohistochemical examination of adipose tissue extracted from the abdominal wall of fetuses as part of standard autopsy protocol. We included 60 MRI scans in fetuses without intra-uterine growth restriction or macrosomia of non-diabetic mothers (range 23-37 weeks of gestation). Fat T1 intensity of all anatomical regions was low in all fetuses before 26 weeks of gestation. It became more hyperintense with increasing gestational age, in the following order: chin and nuchal region, then buttocks, thighs and trunk, and eventually the scalp at 33 weeks of gestation. After 33 weeks of gestation, all fetal subcutaneous tissues demonstrated overall hyperintense signal. This progression followed the conversion at immunohistochemistry of fetal adipose tissue composition from predominant brown to white adipose cells in 19 fetuses (19-41 weeks of gestation). Between 26 weeks and 33 weeks of gestation, subcutaneous fetal fat signal changed in an orderly pattern from chin to buttocks and scalp. This may reflect the conversion from predominant brown to white adipose tissues in subcutaneous fetal fat. (orig.)

  11. Magnetic and electrical studies on La{sub 0.4}Sm{sub 0.1}Ca{sub 0.5}MnO{sub 3} charge ordered manganite

    Energy Technology Data Exchange (ETDEWEB)

    Krichene, A., E-mail: akramkri@hotmail.fr [Laboratoire de Physique des Matériaux, Faculté des Sciences de Sfax, Université de Sfax, B. P. 1171, 3000 Sfax (Tunisia); Solanki, P.S. [Department of Physics, Saurashtra University, Rajkot 360005 (India); Venkateshwarlu, D. [UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore 452017 (India); Rayaprol, S. [UGC-DAE Consortium for Scientific Research, Mumbai Centre, B.A.R.C. Campus, Mumbai 400085 (India); Ganesan, V. [UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore 452017 (India); Boujelben, W. [Laboratoire de Physique des Matériaux, Faculté des Sciences de Sfax, Université de Sfax, B. P. 1171, 3000 Sfax (Tunisia); Kuberkar, D.G. [Department of Physics, Saurashtra University, Rajkot 360005 (India)

    2015-05-01

    We have reported in this work the effect of the partial substitution of lanthanum by samarium on the structural, electrical and magnetic properties of La{sub 0.5}Ca{sub 0.5}MnO{sub 3}. The magnetic study indicated that substitution promotes charge ordering and weakens ferromagnetism. Below T{sub C}=123 K, the compound La{sub 0.4}Sm{sub 0.1}Ca{sub 0.5}MnO{sub 3} is a mixture of ferromagnetic and charge ordered antiferromagnetic domains. Between T{sub C} and T{sub CO}=215 K, the structure is paramagnetic with the presence of antiferromagnetic domains. The fractions of the coexisting magnetic phases are highly dependent on the applied magnetic field value. Resistivity measurements reveal the presence of an insulating-metal transition at T{sub ρ}=123 K. The equality between T{sub C} and T{sub ρ} indicates the presence of a correlation between magnetization and resistivity. For only 1 T applied field, we have reported a colossal value of magnetoresistance reaching 73% around T{sub C}. The origin of this high value is attributed to phase separation phenomenon. - Highlights: • Sm doping enhances charge ordering and weakens ferromagnetism in La{sub 0.5}Ca{sub 0.5}MnO{sub 3.} • Colossal magnetoresistance (73%) is recorded at 123 K for only 1 T applied field. • Phase separation is responsible for the magnetic and the magnetoresistive behavior.

  12. Classification of hematopoietic regions in out-of-phase T1-weighted images. A quantitative comparison study with T1-weighted and STIR images

    International Nuclear Information System (INIS)

    Amano, Yasuo; Amano, Maki; Kijima, Tetsuji; Kumazaki, Tatsuo

    1995-01-01

    The hematopoietic regions were classified into two groups on the basis of out-of-phase T 1 -weighted images (op-TlWI): regions with lower intensity than that of muscle (LH) and regions with intensity equal to or higher than that of muscle (HH). We quantitatively evaluated the differences in signal intensity between LH and HH in order to examine this classification. Forty-two hematopoietic areas in aplastic anemia were classified into two groups of 23 LH and 19 HH. The signal ratios of hematopoietic areas to muscle on TlWI and STIR were calculated, and the differences between LH and HH were statistically evaluated. The signal ratios of LH were significantly higher on TlWI and lower on STIR than those of HH (unpaired t-test, p<0.05). This result indicated that LH consisted of more hypocellular marrow than HH. Op-TlWI were useful in differentiating between LH and HH and defining the degree of hematopoiesis in aplastic anemia. (author)

  13. Combined use of T2-weighted and diffusion-weighted 3-T MR imaging for differentiating uterine sarcomas from benign leiomyomas

    International Nuclear Information System (INIS)

    Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Nakaura, Takeshi; Yanaga, Yumi; Hirai, Toshinori; Saito, Tetsuo; Katabuchi, Hidetaka

    2009-01-01

    The objective of our study was to compare diffusion-weighted imaging (DWI) alone and DWI combined with T2-weighted MRI for the differentiation of uterine sarcomas from benign leiomyomas. T2-weighted imaging and DWI were performed in 103 patients with 103 myometrial tumours, including 8 uterine sarcomas and 95 benign leiomyomas on 3-T MR imaging. The signal intensity (SI) of the tumour on T2-weighted images was quantified as the tumour-myometrium contrast ratio (TCR) by using the following formula: (SI tumour - SI myometrium )/SI myometrium . The TCR or apparent diffusion coefficient (ADC) value alone and then the ADC value combined with T2-weighted imaging were evaluated for differentiation between sarcomas and leiomyomas. The mean ADC value of sarcomas was 0.86 ± 0.11 x 10 -3 m 2 /s, which was significantly lower than that of leiomyomas 1.18 ± 0.24 x 10 -3 m 2 /s; however, there was a substantial overlap. The mean TCR of sarcomas was 0.66 ± 0.71, which was significantly higher than that of the leiomyomas, -0.37 ± 0.34; however, again, there was a considerable overlap. When ADC was less than 1.05 x 10 -3 mm 2 /s and TCR was greater than 0 this condition was considered to confirm a sarcoma; a combination of ADC and TCR achieved a significant improvement without any overlap between sarcomas and leiomyomas (sensitivity 100%, specificity 100%). Our preliminary results indicate that combined DWI and T2-weighted MR imaging is better than DWI alone in the differentiation of uterine sarcomas from benign leiomyomas. (orig.)

  14. Improving surface smoothness and photoluminescence of CdTe(1 1 1)A on Si(1 1 1) substrates grown by molecular beam epitaxy using Mn atoms

    International Nuclear Information System (INIS)

    Wang, Jyh-Shyang; Tsai, Yu-Hsuan; Chen, Chang-Wei; Dai, Zi-Yuan; Tong, Shih-Chang; Yang, Chu-Shou; Wu, Chih-Hung; Yuan, Chi-Tsu; Shen, Ji-Lin

    2014-01-01

    Highlights: • CdTe(1 1 1)A epilayers were grown on Si(1 1 1) substrates by molecular beam epitaxy. • We report an enhanced growth using Mn atoms. • The significant improvements in surface quality and optical properties were found. - Abstract: This work demonstrates an improvement of the molecular beam epitaxial growth of CdTe(1 1 1)A epilayer on Si(1 1 1) substrates using Mn atoms. The reflection high-energy electron diffraction patterns show that the involvement of some Mn atoms in the growth of CdTe(1 1 1)A is even more effective than the use of a buffer layer with a smooth surface for forming good CdTe(1 1 1)A epilayers. 10 K Photoluminescence spectra show that the incorporation of only 2% Mn significantly reduced the intensity of defect-related emissions and considerably increased the integral intensity of exciton-related emissions by a large factor of about 400

  15. Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Kakite, Suguru, E-mail: sugkaki@med.tottori-u.ac.jp [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Fujii, Shinya [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kurosaki, Masamichi [Department of Neurosurgery, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan); Kanasaki, Yoshiko; Matsusue, Eiji; Kaminou, Toshio; Ogawa, Toshihide [Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1, Nishicho, Yonago 683-8503 (Japan)

    2011-07-15

    Introduction: To clarify whether a three-dimensional-gradient echo (3D-GRE) or spin echo (SE) sequence is more useful for evaluating sellar lesions on contrast-enhanced T1-weighted MR imaging at 3.0 Tesla (T). Methods: We retrospectively assessed contrast-enhanced T1-weighted images using 3D-GRE and SE sequences at 3.0 T obtained from 33 consecutive patients with clinically suspected sellar lesions. Two experienced neuroradiologists evaluated the images qualitatively in terms of the following criteria: boundary edge of the cavernous sinus and pituitary gland, border of sellar lesions, delineation of the optic nerve and cranial nerves within the cavernous sinus, susceptibility and flow artifacts, and overall image quality. Results: At 3.0 T, 3D-GRE provided significantly better images than the SE sequence in terms of the border of sellar lesions, delineation of cranial nerves, and overall image quality; there was no significant difference regarding the boundary edge of the cavernous sinus and pituitary gland. In addition, the 3D-GRE sequence showed fewer pulsation artifacts but more susceptibility artifacts. Conclusion: Our results indicate that 3D-GRE is the more suitable sequence for evaluating sellar lesions on contrast-enhanced T1-weighted imaging at 3.0 T.

  16. Structural and magnetic properties of Gd1-xPrxMn2Si2 silicides

    International Nuclear Information System (INIS)

    Kilic, A.; Kervan, S.; Gencer, A.

    2004-01-01

    X-ray powder diffraction, AC susceptibility and differential scanning calorimetry (DSC) studies were performed on the polycrystalline Gd 1-x Pr x Mn 2 Si 2 (0≤x≤1) compounds. All compounds investigated crystallize in the body-centred tetragonal ThCr 2 Si 2 -type structure with the space group I4/mmm. Substitution of Pr for Gd leads to a linear increase of the lattice constants and the unit cell volume. The lattice constants and the unit cell volume obey Vegard's law. At the Curie temperature T C (Gd), the Gd sublattice orders and reconfigures the ordering in the Mn sublattice. This temperature becomes depressed and disappears with increasing Pr content x. The Neel temperature T N (Mn) determined by DSC technique decreases linearly with increasing Pr content x. The results are summarized in the x-T magnetic phase diagram

  17. Neutron scattering study of MnX2 (X = Br, I)

    International Nuclear Information System (INIS)

    Sato, Taku; Kadowaki, Hiroaki.

    1993-01-01

    Successive magnetic phase transitions in MnX 2 (X = Br, I), found by bulk measurements, are studied by neutron scattering experiments. There occur two (T N1 = 2.32K, T N2 = 2.17K) and three (T N1 = 3.95K, T N2 = 3.8K, T N3 = 3.45K) phase transitions in MnBr 2 and MnI 2 , respectively. We have found that magnetic structures of the both compounds in the intermediate temperature phases (MnBr 2 : T N1 > T > T N2 ; MnI 2 : T N1 > T > T N3 ) are transverse sinusoidally-modulated structures with incommensurate wave-vectors which vary as a function of temperature. As the temperature is lowered into the lowest temperature phases, the magnetic structures change via first order transition into ↑↑↓↓ and a helical structure for MnBr 2 and MnI 2 , respectively, which were determined by previous experiments. The successive phase transitions in MnBr 2 are accounted for quantitatively using a mean field approximation of a Hamiltonian consisting of exchange interactions up to third inter- and third intra-layer neighbor sites and the dipolar interaction. (author)

  18. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 X-ray mammography findings

    Energy Technology Data Exchange (ETDEWEB)

    Bickelhaupt, Sebastian; Tesdorff, Jana; Delorme, Stefan; Schlemmer, Heinz-Peter [German Cancer Research Center (dkfz), Department of Radiology, Heidelberg (Germany); Laun, Frederik Bernd; Kuder, Tristan Anselm [German Cancer Research Center (dkfz), Medical Physics in Radiology, Heidelberg (Germany); Lederer, Wolfgang; Teiner, Susanne [Radiological Practice at the ATOS Clinic Heidelberg, Heidelberg (Germany); Maier-Hein, Klaus [German Cancer Research Center (dkfz), Junior Group Medical Image Computing, Heidelberg (Germany); Daniel, Heidi [Radiology Center Mannheim (RZM), Mannheim (Germany); Stieber, Anne [University Hospital Heidelberg, Department of Clinical and Interventional Radiology, Heidelberg (Germany)

    2017-02-15

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm{sup 2}). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. (orig.)

  19. Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma

    International Nuclear Information System (INIS)

    Both, M.; Schultze, J.; Reuter, M.; Bewig, B.; Hubner, R.; Bobis, I.; Noth, R.; Heller, M.; Biederer, J.

    2005-01-01

    Purpose: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. Material and methods: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ('VIBE', TR/TE 4.5/1.9 ms, flip-angle 12 deg., matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). Results: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. Conclusion: The combination of VIBE and HASTE sequence allows for an adequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to

  20. Enhancement of localization phenomena driven by covalency in the SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite

    Energy Technology Data Exchange (ETDEWEB)

    Asensio de Lucas, E.; Alvarez-Serrano, I. [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Cuello, G.J. [Institut Laue-Langevin, 6 rue Jules Horowitz, F-38042 Grenoble (France); Garcia-Hernandez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, E-28049 Cantoblanco, Madrid (Spain); Lopez, M.L., E-mail: marisal@quim.ucm.es [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Pico, C.; Veiga, M.L. [Depto. Quimica Inorganica I, Facultad Ciencias Quimicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain)

    2012-05-05

    Graphical abstract: Enhancement of localization phenomena driven by covalency in the BiSrMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite. The CO/OO phenomena and magnetic clusters (Mn{sub 4}) stabilization at temperatures up to 520 K in BiSrMn{sub 1.75}Ti{sub 0.25}O{sub 6} are connected to a structural transition. The observed enhancement of electronic localization is interpreted considering covalent effects of Ti{sup 4+} and Bi{sup 3+} cations as the main driving force. Highlights: Black-Right-Pointing-Pointer The structural, electronic and magnetic behaviour of the new SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite is reported. Black-Right-Pointing-Pointer A structural transition above 520 K takes place, coinciding with relevant changes in the transport properties. Black-Right-Pointing-Pointer The electronic behavior is interpreted in terms of a remarkably high orbital and charge ordering temperature and cluster models. Black-Right-Pointing-Pointer The observed features are explained considering a scenario in which bonds covalence is enhanced by the Bi{sup 3+} and Ti{sup 4+} cations. - Abstract: Manganites are materials that show remarkable phenomena related to charge orbital ordering (CO/OO) and it is extremely important to understand the fundamental nature of this behaviour. This paper reports on the structural, electronic and magnetic behaviour of the new SrBiMn{sub 1.75}Ti{sub 0.25}O{sub 6} manganite and the dependence of these properties with temperature. A detailed structural analysis has been carried out by electron, X-ray, neutron diffraction between 4 and 700 K. The electron diffraction patterns obtained at room temperature (RT) evidence that the average structure (a{approx}b{approx}{radical}(2)a{sub p} and c {approx} 2a{sub p}) presents a modulation that doubles the a and c lattice parameters. A very high charge ordering (CO) transition temperature of 510 K, similar to that found for the non-doped material, SrBiMn{sub 2}O{sub 6}, is observed. Above this

  1. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    Energy Technology Data Exchange (ETDEWEB)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali [Erciyes University Medical School, Department of Radiology, Kayseri (Turkey); Kumandas, Sefer [Erciyes University Medical School, Department of Neuropediatry, Kayseri (Turkey); Akcakus, Mustafa [Erciyes University Medical School, Department of Neonatalogy, Kayseri (Turkey)

    2005-06-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  2. Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    International Nuclear Information System (INIS)

    Coskun, Abdulhakim; Yikilmaz, Ali; Karahan, Okkes Ibrahim; Manav, Ali; Kumandas, Sefer; Akcakus, Mustafa

    2005-01-01

    Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acute kernicterus by MR imaging. Thirteen neonates who were admitted with jaundice, encephalopathy and indirect hyperbilirubinemia (mean, 37.0 mg/dl) were prospectively evaluated with cranial MR imaging. Pathological signal changes were noted concerning the globus pallidus. Eight of the 13 patients demonstrated bilateral, symmetric increased signal intensity in the globus pallidus on T1-weighted MR imaging. These lesions were not apparent on T2-weighted images. Multiple parenchymal punctuate T1 hyperintense lesions were detected in one patient without globus pallidus involvement. This appearance was consistent with hemorrhage. The MR imaging findings of the other four patients showed no evidence of abnormality. The symmetric involvement of globus pallidus seen as hyperintense on T1-weighted MR imaging is a common and characteristic finding of acute kernicterus. (orig.)

  3. Prostate cancer detection from model-free T1-weighted time series and diffusion imaging

    Science.gov (United States)

    Haq, Nandinee F.; Kozlowski, Piotr; Jones, Edward C.; Chang, Silvia D.; Goldenberg, S. Larry; Moradi, Mehdi

    2015-03-01

    The combination of Dynamic Contrast Enhanced (DCE) images with diffusion MRI has shown great potential in prostate cancer detection. The parameterization of DCE images to generate cancer markers is traditionally performed based on pharmacokinetic modeling. However, pharmacokinetic models make simplistic assumptions about the tissue perfusion process, require the knowledge of contrast agent concentration in a major artery, and the modeling process is sensitive to noise and fitting instabilities. We address this issue by extracting features directly from the DCE T1-weighted time course without modeling. In this work, we employed a set of data-driven features generated by mapping the DCE T1 time course to its principal component space, along with diffusion MRI features to detect prostate cancer. The optimal set of DCE features is extracted with sparse regularized regression through a Least Absolute Shrinkage and Selection Operator (LASSO) model. We show that when our proposed features are used within the multiparametric MRI protocol to replace the pharmacokinetic parameters, the area under ROC curve is 0.91 for peripheral zone classification and 0.87 for whole gland classification. We were able to correctly classify 32 out of 35 peripheral tumor areas identified in the data when the proposed features were used with support vector machine classification. The proposed feature set was used to generate cancer likelihood maps for the prostate gland.

  4. Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Hori, Masatoshi; Kim, Tonsok; Onishi, Hiromitsu; Nakamoto, Atsushi; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imaoka, Izumi; Kagawa, Yuki; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osaka (Japan); Ueguchi, Takashi; Tatsumi, Mitsuaki [Osaka University Hospital, Department of Radiology, Osaka (Japan); Enomoto, Takayuki [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan); Niigata University School of Medicine, Department of Obstetrics and Gynecology, Niigata (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynecology, Osaka (Japan)

    2013-08-15

    To prospectively assess the efficacy of 3-T magnetic resonance (MR) imaging using the three-dimensional turbo spin-echo T2-weighted and diffusion-weighted technique (3D-TSE/DW) compared with that of conventional imaging using the two-dimensional turbo spin-echo T2-weighted and dynamic contrast-enhanced technique (2D-TSE/DCE) for the preoperative staging of endometrial cancer, with pathological analysis as the reference standard. Seventy-one women with endometrial cancer underwent MR imaging using 3D-TSE/DW (b = 1,000 s/mm{sup 2}) and 2D-TSE/DCE. Two radiologists independently assessed the two imaging sets. Accuracy, sensitivity, and specificity for staging were analysed with the McNemar test; the areas under the receiver operating characteristic curve (Az) were compared with a univariate z-score test. The results for assessing deep myometrial invasion, accuracy, sensitivity, specificity and Az, respectively, were as follows: 3D-TSE/DW - observer 1, 87 %, 95 %, 85 % and 0.96; observer 2, 92 %, 84 %, 94 % and 0.95; 2D-TSE/DCE - observer 1, 80 %, 79 %, 81 % and 0.89; observer 2, 86 %, 84 %, 87 % and 0.86. Most of the values were higher with 3D-TSE/DW without significant differences (P > 0.12). For assessing cervical stromal invasion, there were no significant differences in those values for both observers (P > 0.6). Accuracy of 3D-TSE/DW was at least equivalent to that of the conventional technique for the preoperative assessment of endometrial cancer. (orig.)

  5. Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

    Science.gov (United States)

    Ott, Martin; Blaimer, Martin; Breuer, Felix; Grodzki, David; Heismann, Björn; Jakob, Peter

    2016-02-01

    To reduce acoustic noise levels in T 1-weighted and proton-density-weighted turbo spin-echo (TSE) sequences, which typically reach acoustic noise levels up to 100 dB(A) in clinical practice. Five acoustic noise reduction strategies were combined: (1) gradient ramps and shapes were changed from trapezoidal to triangular, (2) variable-encoding-time imaging was implemented to relax the phase-encoding gradient timing, (3) RF pulses were adapted to avoid the need for reversing the polarity of the slice-rewinding gradient, (4) readout bandwidth was increased to provide more time for gradient activity on other axes, (5) the number of slices per TR was reduced to limit the total gradient activity per unit time. We evaluated the influence of each measure on the acoustic noise level, and conducted in vivo measurements on a healthy volunteer. Sound recordings were taken for comparison. An overall acoustic noise reduction of up to 16.8 dB(A) was obtained by the proposed strategies (1-4) and the acquisition of half the number of slices per TR only. Image quality in terms of SNR and CNR was found to be preserved. The proposed measures in this study allowed a threefold reduction in the acoustic perception of T 1-weighted and proton-density-weighted TSE sequences compared to a standard TSE-acquisition. This could be achieved without visible degradation of image quality, showing the potential to improve patient comfort and scan acceptability.

  6. Utility of dual echo T2-weighted turbo spin echo MR imaging for differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions

    International Nuclear Information System (INIS)

    Yang, Dal Mo; Yoon, Myung Hwan; Kim, Hak Soo; Lee, Eun Joo; Kim, Jong Ho; Kim, Hyung Sik; Chung, Jin Woo

    1999-01-01

    To evaluate the additive value of multiphasic contrast-enhanced dynamic MR imaging as a supplement to dual-echo T2-weighted TSE MR imaging for the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions. Two radiologists retrospectively reviewed dual-echo T2-weighted TSE MR images and gadolinium-enhanced MR images in 51 patients with hepatic lesions (28 malignant, 69 benign). For the differentiation of malignant from benign lesions, as seen on dual-echo T2-weighted TSE MR images, we evaluated sensitivity, specificity, and accuracy, and compared with the results with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. In addition, Az values for dual echo T2-weighted MR images were compared with those for dual echo T2-weighted MR images plus multiphasic contrast-enhanced dynamic MR images. For the differentiation of malignant from benign hepatic lesions, as seen on dual-echo T2-weighted TSE images, sensitivity, specificity, and accuracy were 80.0%, 97.5%, and 93.9%, respectively, for lesions less than 3cm in diameter, and 92.3%, 95.0%, and 93.5%, respectively, for those that were 3cm or larger. The results for dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging were 86.7%, 100.0%, and 97.3%, respectively, for lesions less than 3cm, and 92.3%, 100.0%, and 95.7%, respectively for those that were 3cm or larger. There were no significant differences in sensitivity, specificity, or accuracy between the results obtained using dual-echo T2-weighted MR imaging and those obtained with dual-echo T2-weighted MR imaging plus multiphasic contrast-enhanced dynamic MR imaging. Nor were these statistically significant differences in Az values between the two groups. For the differentiation of solid, malignant hepatic lesions from nonsolid, benign hepatic lesions, there is no difference in accuracy between dual-echo T2-weighted TSE MR imaging and the additional use of

  7. Utility decay rates of T1-weighted magnetic resonance imaging contrast based on redox-sensitive paramagnetic nitroxyl contrast agents

    International Nuclear Information System (INIS)

    Matsumoto, Ken-ichiro

    2009-01-01

    The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T 1 -weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T 1 -weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T 1 -weighted MRI contrast (k MRI ) can show an approximate value of the original decay rate (k true ) discretionarily given for simulation with suitable experimental parameters. The difference between k MRI and k true can be sufficiently small under T 1 -weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45deg), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with intravenous (i.v.) doses of below 1.5 γmol/g body weight (b.w.) for mice. The results of this simulation suggest that the k MRI of nitroxyl contrast agents can be the primary index of redox status under biological conditions. (author)

  8. Gd-EOB-DTPA-Enhanced MR Imaging of the Liver: The Effect on T2 Relaxation Times and Apparent Diffusion Coefficient (ADC)

    International Nuclear Information System (INIS)

    Cieszanowski, Andrzej; Podgórska, Joanna; Rosiak, Grzegorz; Maj, Edyta; Grudziński, Ireneusz P.; Kaczyński, Bartosz; Szeszkowski, Wojciech; Milczarek, Krzysztof; Rowiński, Olgierd

    2016-01-01

    To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving

  9. Eu, Gd-Codoped Yttria Nanoprobes for Optical and T1-Weighted Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Timur Sh Atabaev

    2017-02-01

    Full Text Available Nanoprobes with multimodal functionality have attracted significant interest recently because of their potential applications in nanomedicine. This paper reports the successful development of lanthanide-doped Y2O3 nanoprobes for potential applications in optical and magnetic resonance (MR imaging. The morphology, structural, and optical properties of these nanoprobes were characterized by transmission electron microscope (TEM, field emission scanning electron microscope (FESEM, X-ray diffraction (XRD, energy-dispersive X-ray (EDX, and photoluminescence (PL. The cytotoxicity test showed that the prepared lanthanide-doped Y2O3 nanoprobes have good biocompatibility. The obvious contrast enhancement in the T1-weighted MR images suggested that these nanoprobes can be used as a positive contrast agent in MRI. In addition, the clear fluorescence images of the L-929 cells incubated with the nanoprobes highlight their potential for optical imaging. Overall, these results suggest that prepared lanthanide-doped Y2O3 nanoprobes can be used for simultaneous optical and MR imaging.

  10. Comparison of fast spin echo, fast multiplanner spoiled gradient recalled and conventional T1 and T2 weighted imaging for experimentally induced hepatic tumors in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Suh, Jin Suk; Choi, Pil Sik; Lee, Yeon Hee; Yoo, Hyung Sik; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    To compare the ability of tumor detection and the lesion conspicuity between T1- and T2-weighted fast scanning sequence and T1- and T2-weighted conventional spin echo techniques in MR imaging of hepatic tumors. Hepatic tumors were induced on 13 male Sprague-Dawley rats by feeding 3'-methyl-dimethylethyl aminoazobenzene mixed with Miller's III formula for 12 weeks. MR images were obtained with 1.5 T magnet with dual TMJ coil(Sigma, GE Medical systems, Milwaukee, USA). Animals were anesthetized with 150 mg/kg of ketamine hydrochloride. T2 weighted fast spin echo(FSE), conventional spin echo(CSE) T2- and T1WI, fast multiplanner spoiled gradient recalled(FMPSPGR) imaging were obtained. Number of detected tumors and contrast-to-noise ratio of the tumors were compared for each sequence. Overall 110 tumors were developed. 75% of the tumors were detected on FSE. 65% on FMPSPGR, 41% on conventional T2WI, and 41% on T1WI images. For tumors more than 5 mm in diameter, sensitivity was 88% on FMPSPGR, 65% on conventional T2WI, and 81% on T1WI images respectively. CNR of the tumor was 28.94 {+-} 21.6 on FSE, 13.57 {+-} 8.64 on FMPSPGR, 12.62 {+-} 10.65 on CSE T2WI, and 9.47 {+-} 8.05 on CSE T1WI images, which was significantly high on FSE(p<0.05). Fast spin echo T2WI shows highest sensitivity and tumor-to-liver contrast. FMPSPGR imaging is also favorably comparable with conventional T1WI. Therefore, these two pulse sequences can be useful in clinical condition for hepatic MR imaging.

  11. Detection of hepatocellular carcinoma: Comparison of gadoxetic acis-enhanced MIRI, diffusion-weighted imaging, and combined interpretation at 3 T MIRI

    International Nuclear Information System (INIS)

    Park, Seung Hyun; Chung, Yong Eun; Kim, Ki Whang; Kim, Myeong Jin; Hong, Hye Suk

    2013-01-01

    To compare diffusion-weighted imaging (DWI) and gadoxetic acid-enhanced (Gdx) magnetic resonance imaging (MRI), whether alone or in combination, for the detection of hepatocellular carcinoma (HCC) by using 3 T. 84 HCCs in 66 patients (57 men, 9 women; mean age 69.2 years) were examined using 3 T MRI. DWI (b values 0, 50, and 800 sec/mm2) and dynamic gadoxetic acid-enhanced MRI as well as hepatobiliary phase were performed. Images were retrospectively reviewed by two radiologists to compare the diagnostic performances of DWI and Gdx MRI alone and in combination for the detection of HCC. Alternative free response receiver operating characteristic analysis and comparison of sensitivities were used for statistical analysis. The sensitivity of Gdx set (73/84, 87%) was significantly higher than that of DWI set (60.5/84, 72%) for both observers. The Az values of DWI and Gdx MRI for the detection of HCC were not statistically significant for either observer (Az for DWI = 0.818 and 0.864, Az for Gdx MR = 0.902 and 0.842, respectively, p = 0.107 for observer 1 and p = 0.738 for observer 2). The combination of both techniques did not increase the sensitivities of detecting HCC in either observer. When lesions smaller than 2 cm were considered, the DWI set yielded a significantly lower sensitivity as compared with either the Gdx set alone or the combination set. Gadoxetic acid-enhanced MRI was better than DWI for detection the HCC by using 3 T MRI. The combination of DWI and Gdx MRI did not contribute to the successful detection of HCC.

  12. Comparison among T1-weighted magnetic resonance imaging, modified dixon method, and magnetic resonance spectroscopy in measuring bone marrow fat.

    Science.gov (United States)

    Shen, Wei; Gong, Xiuqun; Weiss, Jessica; Jin, Ye

    2013-01-01

    An increasing number of studies are utilizing different magnetic resonance (MR) methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI), modified Dixon method (also called fat fraction MRI (FFMRI)), and magnetic resonance spectroscopy (MRS). Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI). Bone marrow adipose tissue (BMAT) of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 (P BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 (P < 0.001) in femoral necks. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  13. Comparison between T2*- and T2-weighted images in diagnosing rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo; Ito, Hisao; Kubo, Atsushi.

    1995-01-01

    This study was performed to determine the merits of T2 * -weighted images in diagnosing rotator cuff tear, compared with T2-weighted images. T2- and T2 * -weighted images were obtained in 10 asymptomatic volunteers and 94 patients with symptoms referable to the rotator cuff. The increased signal with full thickness of the rotator cuff was not shown on either T2- or T2 * -weighted images in the volunteers. These findings on T2-weighted images and on T2 * -weighted images were observed in 33 and 58 of 94 patients with symptoms, respectively. Every patient who showed these abnormal findings on T2-weighted images had the abnormal findings on T2 * -weighted images. These findings on T2 * -weighted images were wider than those on T2-weighted images in 20 of 33 patients. Surgical findings were available in 21 of 94 patients. Rotator cuff tears were surgically confirmed in 20 patients whose MR images showed increased signal lesions on both T2- and T2 * -weighted images. On the other hand, one patient who did not have rotator cuff tear showed increased signal lesion with full thickness on T2 * -weighted images, but not on T2-weighted images. We think increased signal lesions on T2-weighted images may strongly suggest rotator cuff tear, whereas those on T2 * -weighted images are not specific. (author)

  14. Hydrothermal synthesis of novel Mn(3)O(4) nano-octahedrons with enhanced supercapacitors performances.

    Science.gov (United States)

    Jiang, Hao; Zhao, Ting; Yan, Chaoyi; Ma, Jan; Li, Chunzhong

    2010-10-01

    Uniform and single-crystalline Mn(3)O(4) nano-octahedrons have been successfully synthesized by a simple ethylenediaminetetraacetic acid disodium salt (EDTA-2Na) assisted hydrothermal route. The octahedron structures exhibit a high geometric symmetry with smooth surfaces and the mean side length of square base of octahedrons is ∼160 nm. The structure is reckoned to provide superior functional properties and the nano-size achieved in the present work is noted to further facilitate the material property enhancement. The formation process was proposed to begin with a "dissolution-recrystallization" which is followed by an "Ostwald ripening" mechanism. The Mn(3)O(4) nano-octahedrons exhibited an enhanced specific capacitance of 322 F g(-1) compared with the truncated octahedrons with specific capacitances of 244 F g(-1), making them a promising electrode material for supercapacitors.

  15. Magnetic properties of Pr1-xGdxMn2Ge2 compounds

    International Nuclear Information System (INIS)

    Kilic, A.; Kervan, S.; Oezcan, S.; Gencer, A.

    2004-01-01

    The structure and magnetic properties of the Pr 1-x Gd x Mn 2 Ge 2 (0.0≤x≤1.0) compounds have been investigated by means of X-ray diffraction (XRD), differential scanning calorimetry (DSC) techniques and AC magnetic susceptibility measurements. All compounds crystallize in the ThCr 2 Si 2 -type structure with the space group I4/mmm. The lattice constants and the unit cell volume obey Vegard's law. Samples in this alloy system exhibit a crossover from ferromagnetic ordering for PrMn 2 Ge 2 to antiferromagnetic ordering for GdMn 2 Ge 2 as a function of Gd concentration x. At low temperatures, the rare earth sublattice also orders and reconfigures the ordering in the Mn sublattice. The results are summarized in the x-T magnetic phase diagram

  16. Quantitative and qualitative evaluation of brain diffusion weighted magnetic resonance imaging comparison with 1.5 T and 3.0 T units

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Eun Hoe [Dept. of Radiological Science, Cheongju University, Cheongju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-02-15

    DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging . In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5 T and 3.0 T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5 T.

  17. Efficiency Enhanced Colloidal Mn-Doped Type II Core/Shell ZnSe/CdS Quantum Dot Sensitized Hybrid Solar Cells

    Directory of Open Access Journals (Sweden)

    A. Jamshidi

    2015-01-01

    Full Text Available Colloidal Mn-doped ZnSe/CdS core/shell quantum dots (QDs are synthesized for the first time and employed as a strategy to boost the power conversion efficiency of quantum dot sensitized solar cells. By using Mn-doping as a band gap engineering tool for core/shell QDs an effective improvement of absorption spectra could be obtained. The mid-states generated by a proper Mn content alleviate carrier separation and enhance the electron injection rate, thus facilitating electron transport to the TiO2 substrate. It is demonstrated that a device constructed with 0.25% Mn-doped ZnSe/CdS leads to an enhancement of the electron injection rate and power conversion efficiency by 4 times and 1.3, respectively.

  18. Polyhedral-Like NiMn-Layered Double Hydroxide/Porous Carbon as Electrode for Enhanced Electrochemical Performance Supercapacitors.

    Science.gov (United States)

    Yu, Mei; Liu, Ruili; Liu, Jianhua; Li, Songmei; Ma, Yuxiao

    2017-11-01

    Polyhedral-like NiMn-layered double hydroxide/porous carbon (NiMn-LDH/PC-x) composites are successfully synthesized by hydrothermal method (x = 1, 2 means different mass percent of porous carbon (PC) in composites). The NiMn-LDH/PC-1 composites possess specific capacitance 1634 F g -1 at a current density of 1 A g -1 , and it is much better than that of pure LDH (1095 F g -1 at 1 A g -1 ). Besides, the sample can retain 84.58% of original capacitance after 3000 cycles at 15 A g -1 . An asymmetric supercapacitor with NiMn-LDH/PC-1 as anode and activated carbon as cathode is fabricated, and the supercapacitor can achieve an energy density of 18.60 Wh kg -1 at a power density of 225.03 W kg -1 . The enhanced electrochemical performance attributes to the high faradaic pseudocapacitance of NiMn-LDH, the introduction of PC, and the 3D porous structure of LDH/PC-1 composites. The introduction of PC hinders serious agglomeration of LDH and further accelerates ions transport. The encouraging results indicate that these materials are one of the most potential candidates for energy storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Experimental investigation of temperature dependence of the magnetic susceptibility (T) of manganites La1-xAxMnO3

    International Nuclear Information System (INIS)

    Salakhitdinova, M.; Kuvandikov, O.; Shakarov, Kh.; Shodiev, Z.

    2007-01-01

    Full text: he interest to lanthanoid manganites is based that enormous magnetoresistance is found in them and this materials are capable to test diverse structural and magnetic phase transformations. The work is devoted to experimental investigation of temperature dependence of the magnetic susceptibility (T) of manganites La 1-x A x MnO 3 which doped with Ag, K, Sr metals in wide temperature interval 50-8500 C, as well as to determination of their magnetic characteristics from this dependence. The dependence (T) was measured by the Faraday method with high-temperature magnetic pendulum balance in the atmosphere of refined helium. Maximal relative error of the measurements did not exceed 3 %. The analysis of experimental (T) dependence of investigated manganites has shown that the rise of stoichiometric rate of doped metals the temperature dependence of magnetic susceptibility of manganites monotonously is decreased. (authors)

  20. T1-T2 dual-modal MRI of brain gliomas using PEGylated Gd-doped iron oxide nanoparticles.

    Science.gov (United States)

    Xiao, Ning; Gu, Wei; Wang, Hao; Deng, Yunlong; Shi, Xin; Ye, Ling

    2014-03-01

    To overcome the negative contrast limitations of iron oxide-based contrast agents and to improve the biocompatibility of Gd-chelate contrast agents, PEGylated Gd-doped iron oxide (PEG-GdIO) NPs as a T1-T2 dual-modal contrast agent were synthesized by the polyol method. The transverse relaxivity (r2) and longitudinal relaxivity (r1) of PEG-GdIO were determined to be 66.9 and 65.9 mM(-1) s(-1), respectively. The high r1 value and low r2/r1 ratio make PEG-GdIO NPs suitable as a T1-T2 dual-modal contrast agent. The in vivo MRI demonstrated a brighter contrast enhancement in T1-weighted image and a simultaneous darken effect in T2-weighted MR image compared to the pre-contrast image in the region of glioma. Furthermore, the biocompatibility of PEG-GdIO NPs was confirmed by the in vitro MTT cytotoxicity and in vivo histological analyses (H&E). Therefore, PEG-GdIO NPs hold great potential in T1-T2 dual-modal imaging for the diagnosis of brain glioma. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Study of the structural and thermal stability of Li0.3Co2/3Ni1/6Mn1/6O2

    International Nuclear Information System (INIS)

    Mahmoud, Abdelfattah; Saadoune, Ismael; Difi, Siham; Sougrati, Moulay Tahar; Lippens, Pierre-Emmanuel; Amarilla, José Manuel

    2014-01-01

    Thermal and structural stabilities of the delithiated positive electrode material Li x Co 2/3 Ni 1/6 Mn 1/6 O 2 were studied by X-ray diffraction, magnetic and thermogravimetric analysis. In the opposite to the classical electrode materials LiNiO 2 and LiCoO 2 , the structural symmetry (S.G. R-3 m) of the starting material LiCo 2/3 Ni 1/6 Mn 1/6 O 2 is preserved during the electrochemical cycling with a small variation of the unit cell parameters. Squid measurements evidenced that practically no Ni 2+ ions were present in the lithium slab even after the lithium extraction process. For the thermal stability, the highly oxidized phase Li 0.3 Co 2/3 Ni 1/6 Mn 1/6 O 2 was tested. This delithiated phase undergoes only 5.16% weight loss after heating up to 600 °C. This weight loss has no effect on the structure symmetry as the starting α-NaFeO 2 type structure was preserved during the thermal treatment. The obtained results coupled to the excellent electrochemical features of LiCo 2/3 Ni 1/6 Mn 1/6 O 2 clearly showits ability to compete with the commercialized cathode materials

  2. Interactive thresholded volumetry of abdominal fat using breath-hold T1-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wittsack, H.J.; Cohnen, M.; Jung, G.; Moedder, U.; Poll, L.; Kapitza, C.; Heinemann, L.

    2006-01-01

    Purpose: development of a feasible and reliable method for determining abdominal fat using breath-hold T1-weighted magnetic resonance imaging. Materials and methods: the high image contrast of T1-weighted gradient echo MR sequences makes it possible to differentiate between abdominal fat and non-fat tissue. To obtain a high signal-to-noise ratio, the measurements are usually performed using phased array surface coils. Inhomogeneity of the coil sensitivity leads to inhomogeneity of the image intensities. Therefore, to examine the volume of abdominal fat, an automatic algorithm for intensity correction must be implemented. The analysis of the image histogram results in a threshold to separate fat from other tissue. Automatic segmentation using this threshold results directly in the fat volumes. The separation of intraabdominal and subcutaneous fat is performed by interactive selection in a last step. Results: the described correction of inhomogeneity allows for the segmentation of the images using a global threshold. The use of semiautomatic interactive volumetry makes the analysis more subjective. The variance of volumetry between observers was 4.6%. The mean time for image analysis of a T1-weighted investigation lasted less than 6 minutes. Conclusion: the described method facilitates reliable determination of abdominal fat within a reasonable period of time. Using breath-hold MR sequences, the time of examination is less than 5 minutes per patient. (orig.)

  3. Multireversible redox processes in pentanuclear bis(triple-helical) manganese complexes featuring an oxo-centered triangular {Mn(II)2Mn(III)(μ3-O)}5+ or {Mn(II)Mn(III)2(μ3-O)}6+ core wrapped by two {Mn(II)2(bpp)3}-.

    Science.gov (United States)

    Romain, Sophie; Rich, Jordi; Sens, Cristina; Stoll, Thibaut; Benet-Buchholz, Jordi; Llobet, Antoni; Rodriguez, Montserrat; Romero, Isabel; Clérac, Rodolphe; Mathonière, Corine; Duboc, Carole; Deronzier, Alain; Collomb, Marie-Noëlle

    2011-09-05

    = 2 noninteracting spins (11.75 cm(3) K mol(-1)), and for 1(4+) with three S = 5/2 noninteracting spins (13.125 cm(3) K mol(-1)) suggesting that the {Mn(II)(2)Mn(III)(μ(3)-O)}(5+) and {Mn(II)Mn(III)(2)(μ(3)-O)}(6+) cores behave at low temperature like S = 2 and S = 5/2 spin centers, respectively. The thermal behavior below 40 K highlights the presence of intracomplex magnetic interactions between the two apical spins and the central core, which is antiferromagnetic for 1(3+) leading to an S(T) = 3 and ferromagnetic for 1(4+) giving thus an S(T) = 15/2 ground state.

  4. Comparison among T1-Weighted Magnetic Resonance Imaging, Modified Dixon Method, and Magnetic Resonance Spectroscopy in Measuring Bone Marrow Fat

    Directory of Open Access Journals (Sweden)

    Wei Shen

    2013-01-01

    Full Text Available Introduction. An increasing number of studies are utilizing different magnetic resonance (MR methods to quantify bone marrow fat due to its potential role in osteoporosis. Our aim is to compare the measurements of bone marrow fat among T1-weighted magnetic resonance imaging (MRI, modified Dixon method (also called fat fraction MRI (FFMRI, and magnetic resonance spectroscopy (MRS. Methods. Contiguous MRI scans were acquired in 27 Caucasian postmenopausal women with a modified Dixon method (i.e., FFMRI. Bone marrow adipose tissue (BMAT of T1-weighted MRI and bone marrow fat fraction of the L3 vertebra and femoral necks were quantified using SliceOmatic and Matlab. MRS was also acquired at the L3 vertebra. Results. Correlation among the three MR methods measured bone marrow fat fraction and BMAT ranges from 0.78 to 0.88 in the L3 vertebra. Correlation between BMAT measured by T1-weighted MRI and bone marrow fat fraction measured by modified FFMRI is 0.86 in femoral necks. Conclusion. There are good correlations among T1-weighted MRI, FFMRI, and MRS for bone marrow fat quantification. The inhomogeneous distribution of bone marrow fat, the threshold segmentation of the T1-weighted MRI, and the ambiguity of the FFMRI may partially explain the difference among the three methods.

  5. New MRI findings in Creutzfeldt-Jakob disease: high signal in the globus pallidus on T 1-weighted images

    International Nuclear Information System (INIS)

    Priester, J.A. de; Wilmink, J.T.; Jansen, G.H.; Kruijk, J.R. de

    1999-01-01

    We report a 49-year-old woman with Creutzfeldt-Jakob disease (CJD). In addition to typical high-signal lesions on proton-density and T 2-weighted images there was high signal in the globus pallidus bilaterally on T 1-weighted images. The latter feature has not been described previously and probably due to deposition of prion protein, as found at autopsy. (orig.)

  6. Hyperintense basal ganglia lesions on T1-weighted MR images in asymptomatic patients with hepatic dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Saatci, I. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Cila, A. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey); Dincer, F.F. [Dept. of Radiology, Hacettepe Univ. Hospital, Ankara (Turkey)

    1995-12-31

    Cranial MRI findings in four patients who had hepatic dysfunction, including one with sole hepatic form of Wilson`s disease, were reported. The MR examinations revealed bilateral, symmetric hyperintensity in the globus pallidus, subthalamic nuclei and mesencephalon on T1-weighted images with no corresponding abnormality on T2-weighted sequences. The basal ganglia were normal on CT examinations in all patients. None of the patients had the clinical findings of hepatic encephalopathy. The MR findings in our patients did not correlate with the degree or duration of hepatic dysfunction. (orig.)

  7. Giant magnetostructural coupling in Gd{sub 2/3}Ca{sub 1/3}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Correa, V F; Nieva, G; Haberkorn, N [Comision Nacional de Energia Atomica, Centro Atomico Bariloche, 8400 S. C. de Bariloche (Argentina); Saenger, N [Fachbereich Physik, Universitaet Konstanz, D-78457 Konstanz (Germany); Jorge, G, E-mail: victor.correa@cab.cnea.gov.a [Departamento de Fisica, FCEyN, Universidad de Buenos Aires (Argentina)

    2009-05-01

    We report high magnetic field magnetostructural studies on Gd{sub 2/3}Ca{sub 1/3}MnO{sub 3} single crystals. A giant linear magnetostrictive effect is observed in a wide temperature range (T < 120 K). Above 25 K a large hysteresis is seen reflecting the Mn magnetic moments ordering. At lower temperature (T < 15 K), a rather complicated field dependence arising from the competition between the Mn and Gd magnetic sublattices is observed. The relevance of the Gd ions in the low temperature behavior is further corroborated by specific heat experiments.

  8. Enhanced exchange bias in MnN/CoFe bilayers after high-temperature annealing

    Science.gov (United States)

    Dunz, M.; Schmalhorst, J.; Meinert, M.

    2018-05-01

    We report an exchange bias of more than 2700 Oe at room temperature in MnN/CoFe bilayers after high-temperature annealing. We studied the dependence of exchange bias on the annealing temperature for different MnN thicknesses in detail and found that samples with tMnN > 32nm show an increase of exchange bias for annealing temperatures higher than TA = 400 °C. Maximum exchange bias values exceeding 2000 Oe with reasonably small coercive fields around 600 Oe are achieved for tMnN = 42, 48 nm. The median blocking temperature of those systems is determined to be 180 °C after initial annealing at TA = 525 °C. X-ray diffraction measurements and Auger depth profiling show that the large increase of exchange bias after high-temperature annealing is accompanied by strong nitrogen diffusion into the Ta buffer layer of the stacks.

  9. Effects of Al and Mn, alone and in combination, on growth and nutrient status of red pine seedlings hydroponically grown in nutrient culture solution; Suiko saibaishita akamatsunae no seicho oyobi eiyo jotai ni taisuru Al to Mn no tandoku oyobi fukugo eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Lee, C.; Izuta, T.; Aoki, M.; Totsuka, T. [Tokyo University of Agriculture and Technology, Tokyo (Japan). Faculty of Agriculture

    1997-09-10

    Experiments have made clear the effects of Al and Mn on growth of red pine seedlings hydroponically grown. Analysis was performed on components of plants grown in culture solution into which Al and Mn were added alone or in combination. Photosynthesis velocity and dark respiration velocity of the seedlings were measured when they have fully grown. The following results were obtained: the Al addition reduces dry seedling weight, the T/R ratio (T is dry weight of a seedling above the ground and R is that under the ground) decreases as the addition amount is increased, and the photosynthesis velocity decreases; Al accumulates in roots reducing physiological function of the roots and concentrations of Ca and Mg; the dry weight decreases with increasing Mn addition, but does not affect the T/R ratio; the Mn addition reduces the photosynthesis velocity lowering chlorophyll content in needle leaves; the dark respiration velocity decreases as the Mn amount is increased, but does not affect that for trunks; Ca and Mg concentrations decrease in the trunks and roots; no significant compound effects of Al and Mn are recognized, and the effects are additive; and the concentration at which growth decrease appears is 10 ppm or higher for Al and 60 ppm or higher for Mn. 32 refs., 2 figs., 11 tabs.

  10. Classification of hematopoietic regions in out-of-phase T{sub 1}-weighted images. A quantitative comparison study with T{sub 1}-weighted and STIR images

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Amano, Maki; Kijima, Tetsuji; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1995-07-01

    The hematopoietic regions were classified into two groups on the basis of out-of-phase T{sub 1}-weighted images (op-TlWI): regions with lower intensity than that of muscle (LH) and regions with intensity equal to or higher than that of muscle (HH). We quantitatively evaluated the differences in signal intensity between LH and HH in order to examine this classification. Forty-two hematopoietic areas in aplastic anemia were classified into two groups of 23 LH and 19 HH. The signal ratios of hematopoietic areas to muscle on TlWI and STIR were calculated, and the differences between LH and HH were statistically evaluated. The signal ratios of LH were significantly higher on TlWI and lower on STIR than those of HH (unpaired t-test, p<0.05). This result indicated that LH consisted of more hypocellular marrow than HH. Op-TlWI were useful in differentiating between LH and HH and defining the degree of hematopoiesis in aplastic anemia. (author).

  11. Multivariable analysis of clinical influence factors on liver enhancement of Gd-EOB-DTPA-enhanced 3T MRI; Multivariable Analyse klinischer Einflussfaktoren auf die Signalintensitaet bei Gd-EOB-DTPA 3T-MRT der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Verloh, N.; Haimerl, M.; Stroszczynski, C.; Fellner, C.; Wiggermann, P. [University Hospital Regensburg (Germany). Dept. of Radiology; Zeman, F. [University Hospital Regensburg (Germany). Center for Clinical Trials; Teufel, A. [University Hospital Regensburg (Germany). Dept. of Gastroenterology; Lang, S. [University Hospital Regensburg (Germany). Dept. of Surgery

    2015-01-15

    The purpose of this study was to identify clinical factors influencing Gd-EOB-DTPA liver uptake in patients with healthy liver parenchyma. A total of 124 patients underwent contrast-enhanced MRI with a hepatocyte-specific contrast agent at 3T. T1-weighted volume interpolated breath-hold examination (VIBE) sequences with fat suppression were acquired before and 20 minutes after contrast injection. The relative enhancement (RE) between plain and contrast-enhanced signal intensity was calculated. Simple and multiple linear regression analyses were performed to evaluate clinical factors influencing the relative enhancement. Patients were subdivided into three groups according to their relative liver enhancement (HRE, RE ≥ 100 %; MRE, 100 % > RE > 50 %; NRE, RE ≤ 50 %) and were analyzed according to the relevant risk factors. Simple regression analyses revealed patient age, transaminases (AST, ALT, GGT), liver, spleen and delta-liver volume (the difference between the volumetrically measured liver volume and the estimated liver volume based on body weight) as significant factors influencing relative enhancement. In the multiple analysis the transaminase AST, spleen and delta liver volume remained significant factors influencing relative enhancement. Delta liver volume showed a significant difference between all analyzed groups. Liver enhancement in the hepatobiliary phase depends on a variety of factors. Body weight-adapted administration of Gd-EOB-DTPA may lead to inadequate liver enhancement after 20 minutes especially when the actual liver volume differs from the expected volume.

  12. Extrahepatic portal vein obstruction with parkinsonism and symmetric hyperintense basal ganglia on T1 weighted MRI

    Directory of Open Access Journals (Sweden)

    Jayalakshmi Sita

    2006-01-01

    Full Text Available Abnormal high signal in the globus pallidus on T1 weighted magnetic resonance imaging (MRI of the brain has been well described in patients with chronic liver disease. It may be related to liver dysfunction or portal-systemic shunting. We report a case of extra hepatic portal vein obstruction with portal hypertension and esophageal varices that presented with extra pyramidal features. T1 weighted MRI brain scans showed increased symmetrical signal intensities in the basal ganglia. Normal hepatic function in this patient emphasizes the role of portal- systemic communications in the development of these hyperintensities, which may be due to deposition of paramagnetic substances like manganese in the basal ganglia.

  13. Electronic and magnetic structure of RENi{sub 2}Mn{sub x}-compounds (RE = rare earth, x = 0, 0.25, 0.5, 0.75, 1, 1.25) with respect to ErNi{sub 2}Mn{sub x}

    Energy Technology Data Exchange (ETDEWEB)

    Balinski, Kamil; Kuepper, Karsten [Department of Physics, Osnabrueck University (Germany); Chrobak, Artur [Department of Physics, University of Silesia in Katowice (Poland); Kuznetzsova, T.V.; Mushnikov, N.V.; Marchenkov, V.V. [Institute of Metal Physics, 620990 Ekaterinburg (Russian Federation)

    2015-07-01

    Rare earth (RE) and transition metal (T) compounds are research field since the 1960s. Because of huge magnetocalorical effect and giant magnetostriction the RE-T-compounds are excellent for applications like magnetic cooling or hydrogen storage devices. Besides of that RE-Ni{sub 2}-type of alloys are, due to the relatively simple crystal structure and the fact that Ni{sub 2} does not indicate any %behavior with result in an magnetic moment, excellent candidates for studies of magnetic behavior of RE's and their binding partners. The electronic structure of ErNi{sub 2}Mn{sub x} (x = 0, 0.25, 0.5, 0.75, 1, 1.25) is characterized by XPS and ResPES, the magnetic structure is investigated by SQUID and PPMS techniques, and resistivity measurements are made. Variation in Mn concentration revealed the position of Mn 3d-states at 1.7 eV. The XPS intensity at 1.7 eV can be correlated with the behavior of the Curie temperature and the resistivity. While similar RENi{sub 2}Mn{sub x}-systems, where RE had been replaced by Gd and Tb, highest resistivity, Curie temperature and the highest Mn 3d-valence band state intensity were observed at x = 0.5. ErNi{sub 2}Mn{sub x}-system behave different and show the mentioned maxima at x = 1.25.

  14. New MRI findings in Creutzfeldt-Jakob disease: high signal in the globus pallidus on T 1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Priester, J.A. de; Wilmink, J.T. [Dept. of Radiology, University Hospital Maastricht (Netherlands); Jansen, G.H. [Department of Neuropathology, University Hospital Utrecht (Netherlands); Kruijk, J.R. de [Department of Neurology, University Hospital Maastricht (Netherlands)

    1999-04-01

    We report a 49-year-old woman with Creutzfeldt-Jakob disease (CJD). In addition to typical high-signal lesions on proton-density and T 2-weighted images there was high signal in the globus pallidus bilaterally on T 1-weighted images. The latter feature has not been described previously and probably due to deposition of prion protein, as found at autopsy. (orig.) With 3 figs., 11 refs.

  15. Strain dependence of interfacial antiferromagnetic coupling in La0.7Sr0.3MnO3/SrRuO3 superlattices

    Science.gov (United States)

    Das, Sujit; Herklotz, Andreas; Pippel, Eckhard; Guo, Er-Jia; Rata, Diana; Dörr, Kathrin

    2015-03-01

    We have investigated the magnetic response of La0.7Sr0.3MnO3/SrRuO3 superlattices to biaxial in-plane strain applied in-situ. Superlattices grown on piezoelectric substrates of 0.72PbMg1/3Nb2/3O3-0.28PbTiO3(001) (PMN-PT) show strong antiferromagnetic coupling of the two ferromagnetic components. The coupling field of μ0HAF = 1.8 T is found to change by μ0 ΔHAF / Δɛ ~ -520 mT %-1 under reversible biaxial strain (Δɛ) at 80 K in a [La0.7Sr0.3MnO3(22 Å)/SrRuO3(55 Å)]15 superlattice. This reveals a significant strain effect on interfacial coupling. The applied in-plane compression enhances the ferromagnetic order in the manganite layers which are under as-grown tensile strain. It is thus difficult to disentangle the contributions from strain-dependent antiferromagnetic Mn-O-Ru interface coupling and Mn-O-Mn ferromagnetic double exchange near the interface, since the enhanced magnetic order of Mn spins leads to a larger net coupling of SrRuO3 layers at the interface. We discuss our experimental findings taken into account both the strain-dependent orbital occupation in a single-ion picture and the enhanced Mn order at the interface. This work was supported by the DFG within the Collaborative Research Center SFB 762 ``Functionality of Oxide Interfaces.''

  16. Synthesis and enhanced electrochemical performance of the honeycomb TiO2/LiMn2O4 cathode materials

    DEFF Research Database (Denmark)

    Zhang, J.Y.; Shen, J.X.; Wei, C.B.

    2016-01-01

    angle compare to LiMn2O4, implying that TiO2 doping induced a change of crystal structure. By performing electrochemical measurements, we observed an enhancement of specific capacity (127.28 mAhg−1) and an improvement of cycling stability in the TiO2/LiMn2O4 hybrid materials. After 100 cycles of charge...

  17. Structural and magnetic properties of Mn{sub 12}-Stearate nanomagnets

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Shilpi [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India); Verma, Apoorva [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Srivastava, Avanish K. [Electron and Ion Microscopy Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Gupta, Anurag, E-mail: anurag@mail.nplindia.org [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Singh, Surinder P. [Electron and Ion Microscopy Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India); Singh, Priti, E-mail: pritichem@gmail.com [Quantum Phenomena and Applications Division, National Physical Laboratory, Dr K. S. Krishnan Road, New Delhi 110012 (India); Academy of Scientific and Innovative Research (AcSIR), Chennai 600113 (India)

    2016-07-01

    We present the synthesis and characterization of a fatty acid ligated Mn{sub 12}, [Mn{sub 12}O{sub 12}(CH{sub 3}(CH{sub 2}){sub 16}CO{sub 2}){sub 11}(CH{sub 3}CO{sub 2}){sub 5}(H{sub 2}O){sub 4}], Mn{sub 12}-Stearate (2), a molecular nanomagnet of Mn{sub 12} family that exhibits the enhanced solubility (in organic solvents) and aqueous stability. The chemical composition and morphology of Mn{sub 12}-Stearate have been established using FT-IR, UV–Vis, Raman and {sup 1}H NMR spectroscopy, XRD, elemental analysis, TGA and electron microscopic techniques. The powder XRD and HR-TEM of compound 2 have revealed the formation of crystalline structure. The FC and ZFC magnetization (M) as a function of temperature (T) shows a blocking temperature T{sub B} ∼ 3.0 K. At T ≤ 3 K, the presence of hysteresis and periodic steps in the measured M-H loops indicate the presence of quantum tunnelling of magnetization (QTM). In the same T region, the observed decrease of magnetic relaxation rate with a decrease in T further implies the QTM to be thermally assisted. The estimated anisotropy energy barrier is found to be ∼35 K. - Highlights: • A fatty acid ligated mixed-carboxylate SMM, Mn{sub 12}-Stearate, has been synthesized. • Powder XRD and HRTEM images show crystalline ordering in the synthesized cluster. • The cluster exhibits higher blocking temperature and periodic steps in hysteresis.

  18. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    International Nuclear Information System (INIS)

    Mürtz, P.; Kaschner, M.; Lakghomi, A.; Gieseke, J.; Willinek, W.A.; Schild, H.H.; Thomas, D.

    2015-01-01

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus

  19. Diffusion-weighted MR neurography of the brachial and lumbosacral plexus: 3.0 T versus 1.5 T imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mürtz, P., E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Kaschner, M., E-mail: Marius.Kaschner@med.uni-duesseldorf.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Lakghomi, A., E-mail: Asadeh.Lakghomi@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Gieseke, J., E-mail: juergen.gieseke@ukb.uni-bonn.de [Philips Healthcare, Lübeckertordamm 5, 20099 Hamburg (Germany); Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Willinek, W.A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Schild, H.H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany); Thomas, D., E-mail: daniel.thomas@ukb.uni-bonn.de [Department of Radiology, University of Bonn, Sigmund-Freud-Straße 25, 53105 Bonn (Germany)

    2015-04-15

    Highlights: •DW MRN of brachial and lumbosacral plexus at 1.5 T and at 3.0 T was compared. •For lumbosacral plexus, nerve conspicuity on MIP images was superior at 3.0 T, also visible length and mean sharpness of the nerves. •For brachial plexus, nerve conspicuity at 3.0 T was rather inferior, nerve length was not significantly different, mean sharpness was superior at 3.0 T. -- Abstract: Purpose: To compare intraindividually the nerve conspicuity of the brachial and lumbosacral plexus on diffusion-weighted (DW) MR neurography (MRN) at two different field strengths. Materials and methods: 16 healthy volunteers were investigated at 3.0 T and 1.5 T applying optimized variants of a DW spin-echo echo-planar imaging sequence with short TI inversion recovery fat suppression. Full-volume (FV) and curved sub-volume (CSV) maximum intensity projection (MIP) images were reconstructed and nerve conspicuity was visually assessed. Moreover, visible length and sharpness of the nerves were quantitatively analyzed. Results: On FV MIP images, nerve conspicuity at 3.0 T compared to 1.5 T was worse for brachial plexus (P = 0.00228), but better for lumbosacral plexus (P = 0.00666). On CSV MIP images, nerve conspicuity did not differ significantly for brachial plexus, but was better at 3.0 T for lumbosacral plexus (P = 0.00091). The visible length of the analyzed nerves did not differ significantly with the exception of some lumbosacral nerves, which were significantly longer at 3.0 T. The sharpness of all investigated nerves was significantly higher at 3.0 T by about 40–60% for cervical and 97–169% for lumbosacral nerves. Conclusion: DW MRN imaging at 3.0 T compared to 1.5 T is superior for lumbosacral plexus, but not for brachial plexus.

  20. Eutectic Al-Si-Cu-Fe-Mn alloys with enhanced mechanical properties at room and elevated temperature

    International Nuclear Information System (INIS)

    Wang, E.R.; Hui, X.D.; Chen, G.L.

    2011-01-01

    Highlights: → Fabricated a kind of high performance Al-Si alloy with low production costs. → Clarified two different morphologies of α-Fe and corresponding crystal structures. → Analyzed the crystallography of Cu-rich phases before and after T6 treatment. → Fracture mechanism of precipitates in experimental alloys during tensile process. -- Abstract: In this paper, we report a novel kind of eutectic Al-Si-Cu-Fe-Mn alloy with ultimate tensile strength up to 336 MPa and 144.3 MPa at room temperature and 300 o C, respectively. This kind of alloy was prepared by metal mold casting followed by T6 treatment. The microstructure is composed of eutectic and primary Si, α-Fe, Al 2 Cu and α-Al phases. Iron-rich phases, which were identified as BCC type of α-Fe (Al 15 (Fe,Mn) 3 Si 2 ), exist in blocky and dendrite forms. Tiny blocky Al 2 Cu crystals disperse in α-Fe dendrites or at the grain boundaries of α-Al. During T6 treatment, Cu atoms aggregate from the super-saturation solid solution to form GP zones, θ'' or θ'. Further analysis found that the enhanced mechanical properties of the experimental alloy are mainly attributed to the formation of α-Fe and copper-rich phases.

  1. Low-temperature molar heat capacities and entropies of MnO2 (pyrolusite), Mn3O4 (hausmanite), and Mn2O3 (bixbyite)

    Science.gov (United States)

    Robie, R.A.; Hemingway, B.S.

    1985-01-01

    Pyrolusite (MnO2), hausmanite (Mn3O4), and bixbyite (Mn2O3), are important ore minerals of manganese and accurate values for their thermodynamic properties are desirable to understand better the {p(O2), T} conditions of their formation. To provide accurate values for the entropies of these important manganese minerals, we have measured their heat capacities between approximately 5 and 380 K using a fully automatic adiabatically-shielded calorimeter. All three minerals are paramagnetic above 100 K and become antiferromagnetic or ferrimagnetic at lower temperatures. This transition is expressed by a sharp ??-type anomaly in Cpmo for each compound with Ne??el temperatures TN of (92.2??0.2), (43.1??0.2), and (79.45??0.05) K for MnO2, Mn3O4, and Mn2O3, respectively. In addition, at T ??? 308 K, Mn2O3 undergoes a crystallographic transition, from orthorhombic (at low temperatures) to cubic. A significant thermal effect is associated with this change. Hausmanite is ferrimagnetic below TN and in addition to the normal ??-shape of the heat-capacity maxima in MnO2 and Mn2O3, it has a second rounded maximum at 40.5 K. The origin of this subsidiary bump in the heat capacity is unknown but may be related to a similar "anomalous bump" in the curve of magnetization against temperature at about 39 K observed by Dwight and Menyuk.(1) At 298.15 K the standard molar entropies of MnO2, Mn3O4, and Mn2O3, are (52.75??0.07), (164.1??0.2), and (113.7??0.2) J??K-1??mol-1, respectively. Our value for Mn3O4 is greater than that adopted in the National Bureau of Standards tables(2) by 14 per cent. ?? 1985.

  2. Enhanced microwave absorption properties of MnO{sub 2} hollow microspheres consisted of MnO{sub 2} nanoribbons synthesized by a facile hydrothermal method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan; Han, Bingqian; Chen, Nan; Deng, Dongyang; Guan, Hongtao [Department of Materials Science and Engineering, Yunnan University, 650091, Kunming (China); Wang, Yude, E-mail: ydwang@ynu.edu.cn [Department of Materials Science and Engineering, Yunnan University, 650091, Kunming (China); Yunnan Province Key Lab of Micro-Nano Materials and Technology, Yunnan University, 650091, Kunming (China)

    2016-08-15

    MnO{sub 2} hollow microspheres consisted of nanoribbons were successfully fabricated via a facile hydrothermal method with SiO{sub 2} sphere templates. The crystal structure, morphology and microwave absorption properties in X and Ku band of the as-synthesized samples were characterized by powder X-ray diffraction (XRD), transmission electron microscopy (TEM) and a vector network analyzer. The results show that the three-dimensional (3D) hollow microspheres are assembled by ultra thin and narrow one-dimensional (1D) nanoribbons. A rational process for the formation of hollow microspheres is proposed. The 3D MnO{sub 2} hollow microspheres possess improved dielectric and magnetic properties than the 1D nanoribbons prepared by the same procedures with the absence of SiO{sub 2} hard templates, which are closely related to their special nanostructures. The MnO{sub 2} microspheres also show much better microwave absorption properties in X (8–12 GHz) and Ku (12–18 GHz) microwave band compared with 1D MnO{sub 2} nanoribbons. The minimum reflection loss of −40 dB for hollow microsphere can be observed at 14.2 GHz and reflection loss below −10 dB is 3.5 GHz with a thickness of only 4 mm. The possible mechanism for the enhanced microwave absorption properties is also discussed. - Graphical abstract: MnO{sub 2} hollow microspheres composed of nanoribbons show the excellent microwave absorption properties in X and Ku band. - Highlights: • MnO{sub 2} hollow microspheres consisted of MnO{sub 2} nanoribbons were successfully prepared. • MnO{sub 2} hollow microspheres possess good microwave absorption performances. • The excellent microwave absorption properties are in X and Ku microwave band. • Electromagnetic impedance matching is great contribution to absorption properties.

  3. Assessment of Myocardial Fibrosis in Mice Using a T2*-Weighted 3D Radial Magnetic Resonance Imaging Sequence.

    Directory of Open Access Journals (Sweden)

    Bastiaan J van Nierop

    Full Text Available Myocardial fibrosis is a common hallmark of many diseases of the heart. Late gadolinium enhanced MRI is a powerful tool to image replacement fibrosis after myocardial infarction (MI. Interstitial fibrosis can be assessed indirectly from an extracellular volume fraction measurement using contrast-enhanced T1 mapping. Detection of short T2* species resulting from fibrotic tissue may provide an attractive non-contrast-enhanced alternative to directly visualize the presence of both replacement and interstitial fibrosis.To goal of this paper was to explore the use of a T2*-weighted radial sequence for the visualization of fibrosis in mouse heart.C57BL/6 mice were studied with MI (n = 20, replacement fibrosis, transverse aortic constriction (TAC (n = 18, diffuse fibrosis, and as control (n = 10. 3D center-out radial T2*-weighted images with varying TE were acquired in vivo and ex vivo (TE = 21 μs-4 ms. Ex vivo T2*-weighted signal decay with TE was analyzed using a 3-component model. Subtraction of short- and long-TE images was used to highlight fibrotic tissue with short T2*. The presence of fibrosis was validated using histology and correlated to MRI findings.Detailed ex vivo T2*-weighted signal analysis revealed a fast (T2*fast, slow (T2*slow and lipid (T2*lipid pool. T2*fast remained essentially constant. Infarct T2*slow decreased significantly, while a moderate decrease was observed in remote tissue in post-MI hearts and in TAC hearts. T2*slow correlated with the presence of diffuse fibrosis in TAC hearts (r = 0.82, P = 0.01. Ex vivo and in vivo subtraction images depicted a positive contrast in the infarct co-localizing with the scar. Infarct volumes from histology and subtraction images linearly correlated (r = 0.94, P<0.001. Region-of-interest analysis in the in vivo post-MI and TAC hearts revealed significant T2* shortening due to fibrosis, in agreement with the ex vivo results. However, in vivo contrast on subtraction images was rather poor

  4. Gadolinium-enhanced MR imaging in evaluation of cholesteatoma

    International Nuclear Information System (INIS)

    Sugihara, M.; Sugimura, K.; Ishida, T.; Fujino, A.; Miyakuni, Y.

    1990-01-01

    It was sometimes difficult to differentiate cholesteatoma from accompanied granuloma, cholesterol granuloma, or mastoiditis on high-resolution CT. This study was designed to assess the reliability with which cholesteatoma can be differentiated from those accompanied lesions by gadolinium-enhanced MR imaging. Eight patients suspected to have cholesteatoma were evaluated with GD-DTPA-enhanced MR imaging with a 1.5-T MR imaging GE Signa unit. axial pre- and postcontrast T1-weighted (TR/TE, 600/20) and T2-weighted (TR/TE, 2,000/70) images were studied. MR imaging findings were compared with histologic findings (13 lesions), which included cholesteatoma (n = 6), granuloma (n = 4), cholesterol granuloma (n = 2), and mastoiditis (n = 1). Cholesteatoma had an intermediate to high signal intensity (SI) similar to that of granuloma on both T1- and T2-weighted images. Cholesterol granulomas showed high SI on both T1- and T2-weighted images. Mastoiditis demonstrated marked high SI on T2-weighted images. Cholesterol granuloma and mastoiditis can be distinguished from cholesteatoma or granuloma on both T1- and T2-weighted images. On Gd-DTPA-enhanced images, there was marked enhancement of all granulomas. However, no cholesteatoma enhancement was seen in all six lesions. Gd-DTPA-enhanced images were able to distinguish cholesteatoma from granuloma and to estimate the exact extent of cholesteatoma. Gd-DTPA-enhanced MR imaging is valuable in the evaluation and management of cholesteatoma

  5. Butyrate transcriptionally enhances peptide transporter PepT1 expression and activity.

    Directory of Open Access Journals (Sweden)

    Guillaume Dalmasso

    Full Text Available BACKGROUND: PepT1, an intestinal epithelial apical di/tripeptide transporter, is normally expressed in the small intestine and induced in colon during chronic inflammation. This study aimed at investigating PepT1 regulation by butyrate, a short-chain fatty acid produced by commensal bacteria and accumulated inside inflamed colonocyte. RESULTS: We found that butyrate treatment of human intestinal epithelial Caco2-BBE cells increased human PepT1 (hPepT1 promoter activity in a dose- and time-dependent manner, with maximal activity observed in cells treated with 5 mM butyrate for 24 h. Under this condition, hPepT1 promoter activity, mRNA and protein expression levels were increased as assessed by luciferase assay, real-time RT-PCR and Western blot, respectively. hPepT1 transport activity was accordingly increased by approximately 2.5-fold. Butyrate did not alter hPepT1 mRNA half-life indicating that butyrate acts at the transcriptional level. Molecular analyses revealed that Cdx2 is the most important transcription factor for butyrate-induced increase of hPepT1 expression and activity in Caco2-BBE cells. Butyrate-activated Cdx2 binding to hPepT1 promoter was confirmed by gel shift and chromatin immunoprecipitation. Moreover, Caco2-BBE cells overexpressing Cdx2 exhibited greater hPepT1 expression level than wild-type cells. Finally, treatment of mice with 5 mM butyrate added to drinking water for 24 h increased colonic PepT1 mRNA and protein expression levels, as well as enhanced PepT1 transport activity in colonic apical membranes vesicles. CONCLUSIONS: Collectively, our results demonstrate that butyrate increases PepT1 expression and activity in colonic epithelial cells, which provides a new understanding of PepT1 regulation during chronic inflammation.

  6. Structural Directed Growth of Ultrathin Parallel Birnessite on β-MnO2 for High-Performance Asymmetric Supercapacitors.

    Science.gov (United States)

    Zhu, Shijin; Li, Li; Liu, Jiabin; Wang, Hongtao; Wang, Tian; Zhang, Yuxin; Zhang, Lili; Ruoff, Rodney S; Dong, Fan

    2018-02-27

    Two-dimensional birnessite has attracted attention for electrochemical energy storage because of the presence of redox active Mn 4+ /Mn 3+ ions and spacious interlayer channels available for ions diffusion. However, current strategies are largely limited to enhancing the electrical conductivity of birnessite. One key limitation affecting the electrochemical properties of birnessite is the poor utilization of the MnO 6 unit. Here, we assemble β-MnO 2 /birnessite core-shell structure that exploits the exposed crystal face of β-MnO 2 as the core and ultrathin birnessite sheets that have the structure advantage to enhance the utilization efficiency of the Mn from the bulk. Our birnessite that has sheets parallel to each other is found to have unusual crystal structure with interlayer spacing, Mn(III)/Mn(IV) ratio and the content of the balancing cations differing from that of the common birnessite. The substrate directed growth mechanism is carefully investigated. The as-prepared core-shell nanostructures enhance the exposed surface area of birnessite and achieve high electrochemical performances (for example, 657 F g -1 in 1 M Na 2 SO 4 electrolyte based on the weight of parallel birnessite) and excellent rate capability over a potential window of up to 1.2 V. This strategy opens avenues for fundamental studies of birnessite and its properties and suggests the possibility of its use in energy storage and other applications. The potential window of an asymmetric supercapacitor that was assembled with this material can be enlarged to 2.2 V (in aqueous electrolyte) with a good cycling ability.

  7. High signal in the adenohypophysis on T1-weighted images presumably due to manganese deposits in patients on long-term parenteral nutrition

    International Nuclear Information System (INIS)

    Dietemann, J.L.; Diniz, R.L.F.C.; Reis, M. Jr.; Neugroschl, C.; Soehsten, S. von; Reimund, J.M.; Baumann, R.; Warter, J.M.

    1998-01-01

    Hypermanganesaemia is reported in patients on long-term parenteral nutrition. Deposition of manganese, giving high signal on T1-weighted images, may involve the basal ganglia. MRI in nine patients (mean age 51 years, range 31-75 years) on long-term parenteral nutrition (mean duration 30 months, range 6-126 months), demonstrated high signal in the anterior pituitary gland on T1-weighted sagittal and coronal images. The gland appeared normal on T2-weighted images. Signal intensity in the basal ganglia on T1-weighted images was increased in all patients. Endocrine assessment showed no significant abnormality. Neurological examination showed a mild parkinsonian movement disorder in one patient. Hypermanganaesemia was present in all nine (1.3-2.8 μmol/l, mean 1.87 μmol/l). The high signal in the anterior pituitary gland was probably related to deposition of paramagnetic substances, especially manganese. (orig.)

  8. Low-temperature phase MnBi compound: A potential candidate for rare-earth free permanent magnets

    International Nuclear Information System (INIS)

    Ly, V.; Wu, X.; Smillie, L.; Shoji, T.; Kato, A.; Manabe, A.; Suzuki, K.

    2014-01-01

    Highlights: • The spin reorientation temperature of MnBi is suppressed by nanoscale grain refinement. • Hardness parameter of MnBi reaches as large as 2.8 at 580 K. • MnBi has a great potential as a hard phase in rare-earth free nanocomposite magnets. • Improving the surface passivity is a remaining task for MnBi-based permanent magnets. - Abstract: The low-temperature phase (LTP) MnBi is one of the few rare-earth free compounds that exhibit a large magnetocrystalline anisotropy energy in the order of 10 6 J/m 3 . A large coercive field (μ 0 H cj ) above 1 T can be obtained readily by reducing the crystallite size (D) through mechanical grinding (MG). The room-temperature H cj values follow a phenomenological expression μ 0 H cj = μ 0 H a (δ/D) n where the anisotropy field (μ 0 H a ) is ∼4 T, the Bloch wall width (δ) is 7 nm and the exponent (n) is about 0.7 in our study. The grain refinement upon MG is accompanied by suppression of the spin reorientation transition temperature (T SR ) from 110 K to below 50 K. The coercive field starts to exhibit positive temperature dependence approximately 50 K above T SR and the room-temperature magnetic hardening induced by MG could partially be brought about by the lowered onset of this positive temperature dependence. The suppression of T SR by MG is likely to be induced by the surface anisotropy with which the 2nd order crystal field term is enhanced. One of the shortcomings of LTP-MnBi is its poor phase stability under the ambient atmosphere. The spontaneous magnetization decreases considerably after room-temperature aging for 1 week. This is due to oxidation of Mn which leads to decomposition of the MnBi phase. Hence, the surface passivity needs to be established before this material is considered for a permanent magnet in practical uses. Another shortcoming is the limited spontaneous magnetization. The theoretical upper limit of the maximum energy product in LTP-MnBi remains only a quarter of that in Nd 2

  9. Low-temperature phase MnBi compound: A potential candidate for rare-earth free permanent magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ly, V.; Wu, X.; Smillie, L. [Department of Materials Engineering, Monash University, Clayton, VIC 3800 (Australia); Shoji, T.; Kato, A.; Manabe, A. [Toyota Motor Corporation, Mishuku, Susono, Shizuoka 410-1193 (Japan); Suzuki, K., E-mail: kiyonori.suzuki@monash.edu [Department of Materials Engineering, Monash University, Clayton, VIC 3800 (Australia)

    2014-12-05

    Highlights: • The spin reorientation temperature of MnBi is suppressed by nanoscale grain refinement. • Hardness parameter of MnBi reaches as large as 2.8 at 580 K. • MnBi has a great potential as a hard phase in rare-earth free nanocomposite magnets. • Improving the surface passivity is a remaining task for MnBi-based permanent magnets. - Abstract: The low-temperature phase (LTP) MnBi is one of the few rare-earth free compounds that exhibit a large magnetocrystalline anisotropy energy in the order of 10{sup 6} J/m{sup 3}. A large coercive field (μ{sub 0}H{sub cj}) above 1 T can be obtained readily by reducing the crystallite size (D) through mechanical grinding (MG). The room-temperature H{sub cj} values follow a phenomenological expression μ{sub 0}H{sub cj} = μ{sub 0}H{sub a}(δ/D){sup n} where the anisotropy field (μ{sub 0}H{sub a}) is ∼4 T, the Bloch wall width (δ) is 7 nm and the exponent (n) is about 0.7 in our study. The grain refinement upon MG is accompanied by suppression of the spin reorientation transition temperature (T{sub SR}) from 110 K to below 50 K. The coercive field starts to exhibit positive temperature dependence approximately 50 K above T{sub SR} and the room-temperature magnetic hardening induced by MG could partially be brought about by the lowered onset of this positive temperature dependence. The suppression of T{sub SR} by MG is likely to be induced by the surface anisotropy with which the 2nd order crystal field term is enhanced. One of the shortcomings of LTP-MnBi is its poor phase stability under the ambient atmosphere. The spontaneous magnetization decreases considerably after room-temperature aging for 1 week. This is due to oxidation of Mn which leads to decomposition of the MnBi phase. Hence, the surface passivity needs to be established before this material is considered for a permanent magnet in practical uses. Another shortcoming is the limited spontaneous magnetization. The theoretical upper limit of the maximum

  10. Susceptibility weighted imaging (SWI) of the kidney at 3 T. Initial results

    International Nuclear Information System (INIS)

    Mie, Moritz B.; Zoellner, Frank G.; Heilmann, Melanie; Schad, Lothar R.; Nissen, Johanna C.; Schoenberg, Stefan O.; Michaely, Henrik J.

    2010-01-01

    Susceptibility weighted imaging provides diagnostic information in strokes, hemorrhages, and cerebral tumors and has proven to be a valuable tool in imaging venous vessels in the cerebrum. The SWI principle is based on the weighting of T 2 * weighted magnitude images with a phase mask, therewith improving image contrast of veins or neighbouring structures of different susceptibility, in general. T 2 * weighted MRI is already used for assessment of kidney function. In this paper, the feasibility of SWI on kidneys was investigated. Translation of SWI from the brain to the kidneys comes along with two main challenges: (i) organ motion due to breathing and (ii) a higher oxygenation level of renal veins compared to the brain. To handle these problems, the acquisition time has been cut down to allow for breath-hold examinations, and different post-processing methods including a new phase mask were investigated to visualize renal veins. Results showed that by a new post-processing strategy SWI contrast was enhanced on average by a factor of 1.33 compared to the standard phase mask. In summary, initial experiences of SWI on the kidneys demonstrated the feasibility. However, further technical developments have to be performed to make this technology applicable in clinical abdominal MRI. (orig.)

  11. In Vivo Visualization of Active Polysynaptic Circuits With Longitudinal Manganese-Enhanced MRI (MEMRI

    Directory of Open Access Journals (Sweden)

    Suellen Almeida-Corrêa

    2018-05-01

    Full Text Available Manganese-enhanced magnetic resonance imaging (MEMRI is a powerful tool for in vivo non-invasive whole-brain mapping of neuronal activity. Mn2+ enters active neurons via voltage-gated calcium channels and increases local contrast in T1-weighted images. Given the property of Mn2+ of axonal transport, this technique can also be used for tract tracing after local administration of the contrast agent. However, MEMRI is still not widely employed in basic research due to the lack of a complete description of the Mn2+ dynamics in the brain. Here, we sought to investigate how the activity state of neurons modulates interneuronal Mn2+ transport. To this end, we injected mice with low dose MnCl2 2. (i.p., 20 mg/kg; repeatedly for 8 days followed by two MEMRI scans at an interval of 1 week without further MnCl2 injections. We assessed changes in T1 contrast intensity before (scan 1 and after (scan 2 partial sensory deprivation (unilateral whisker trimming, while keeping the animals in a sensory enriched environment. After correcting for the general decay in Mn2+ content, whole brain analysis revealed a single cluster with higher signal in scan 1 compared to scan 2: the left barrel cortex corresponding to the right untrimmed whiskers. In the inverse contrast (scan 2 > scan 1, a number of brain structures, including many efferents of the left barrel cortex were observed. These results suggest that continuous neuronal activity elicited by ongoing sensory stimulation accelerates Mn2+ transport from the uptake site to its projection terminals, while the blockage of sensory-input and the resulting decrease in neuronal activity attenuates Mn2+ transport. The description of this critical property of Mn2+ dynamics in the brain allows a better understanding of MEMRI functional mechanisms, which will lead to more carefully designed experiments and clearer interpretation of the results.

  12. Neutron diffraction study of the magnetic structures of CeMn2Ge2 and CeMn2Si2

    International Nuclear Information System (INIS)

    Fernandez-Baca, J.A.; Chakoumakos, B.C.; Hill, P.; Ali, N.

    1995-01-01

    The magnetic properties of the layered compounds of the form RMn 2 X 2 (R = Rare Earth, X = Si, Ge) have been thought to be sensitive to the intralayer Mn-Mn distance. Thus it has been reported that the Mn moments in CeMn 2 Si 2 are aligned antiferromagnetically (AF) below T N = 380K, while the Mn moments in CeMn 2 Ge 2 are ferromagnetic (FM) below T C = 316K. Recently, however, there has been some debate about the actual magnetic structures of this family of compounds, and for this reason the authors have performed high-resolution neutron powder diffraction measurements on these compounds for temperatures between 12K and 550K. The measurements indicate that at high temperatures both compounds are paramagnetic. Below T N = 380K CeMn 2 Si 2 becomes a collinear AF, with a structure similar to that reported by Siek et al. in which the magnetic propagation vector is τ = (0 0 1). CeMn 2 Ge 2 on the other hand, exhibits two different magnetic transitions. At T N ∼ 415K there is a transition to a collinear AF phase characterized by the commensurate propagation wavevector τ = (1 0 1). At T C = 318K there is a transition to a conical structure with a ferromagnetic component along the c-axis and a helical component in the ab plane. The helical component is characterized by the incommensurate propagation vector τ = (1 0 1-q z ), where q z is temperature dependent. These findings are consistent with the recent results of Welter et al

  13. High signal in the adenohypophysis on T1-weighted images presumably due to manganese deposits in patients on long-term parenteral nutrition

    Energy Technology Data Exchange (ETDEWEB)

    Dietemann, J.L.; Diniz, R.L.F.C.; Reis, M. Jr.; Neugroschl, C.; Soehsten, S. von [Department of Radiology 2, University Hospital of Strasbourg (France); Reimund, J.M.; Baumann, R. [Department of Hepatogastroenterology, University Hospital of Strasbourg (France); Warter, J.M. [Department of Neurology, University Hospital of Strasbourg (France)

    1998-12-01

    Hypermanganesaemia is reported in patients on long-term parenteral nutrition. Deposition of manganese, giving high signal on T1-weighted images, may involve the basal ganglia. MRI in nine patients (mean age 51 years, range 31-75 years) on long-term parenteral nutrition (mean duration 30 months, range 6-126 months), demonstrated high signal in the anterior pituitary gland on T1-weighted sagittal and coronal images. The gland appeared normal on T2-weighted images. Signal intensity in the basal ganglia on T1-weighted images was increased in all patients. Endocrine assessment showed no significant abnormality. Neurological examination showed a mild parkinsonian movement disorder in one patient. Hypermanganaesemia was present in all nine (1.3-2.8 {mu}mol/l, mean 1.87 {mu}mol/l). The high signal in the anterior pituitary gland was probably related to deposition of paramagnetic substances, especially manganese. (orig.) With 2 figs., 1 tab., 17 refs.

  14. Mechanical responses of Zn{sub 1-x}Mn{sub x}O epitaxial thin films

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Teng-Ruey [Department of Industrial Engineering and Management, Nan Kai University of Techonology, Nantou 54243, Taiwan (China); Tsai, Chien-Huang, E-mail: chtsai12@gmail.com [Department of Automation Engineering, Nan Kai University of Techonology, Nantou 54243, Taiwan (China)

    2011-10-15

    In this study, we used nanoindentation to investigate the effect of the doping of Mn into ZnO buffer layers on the epitaxial growth of ZnO through plasma-assisted molecular beam epitaxy on c-plane sapphire substrates. We characterized the variation of the mechanical properties of Zn{sub 1-x}Mn{sub x}O alloys as a function of the Mn content in the range (x) from 0 to 0.16, as well as analyzing their microstructures using high-resolution transmission electron microscopy. The presence of the Mn-doped ZnO buffer layer enhanced the nanomechanical properties of the ZnO epilayers significantly. From their Berkovich indenter responses, plots of the Young's modulus (E) and hardness (H) of these films revealed that the value of E increased relatively steadily upon increasing the Mn composition, whereas the value of H reached its maximum when x was equal to 0.16. This discrepancy suggests that Zn{sub 1-x}Mn{sub x}O epilayers of higher Mn contents had higher shear resistances.

  15. Preparation of Mn doped CeO_2 nanoparticles with enhanced ferromagnetism

    International Nuclear Information System (INIS)

    Ravi, S.; Winfred Shashikanth, F.

    2017-01-01

    Spherical-like CeO_2 and Mn-doped CeO_2 using 6-aminohexanoic acid as surfactant exhibit enhanced ferromagnetism. The optical absorption spectra reveal a red shift with a band gap of 2.51 eV. The mechanics of ferromagnetism and the red shift were analyzed. These results provide a promising platform for developing a dilute magnetic semiconductor in spintronics. - Highlights: • Pure and Mn-doped CeO_2 is prepared with aminohexanoic acid as capping. • They exhibit wide optical absorption with red-shift in their band gap. • Mn-doped CeO_2 nanoparticle exhibit hysteresis at room temperature. • Results were promising to use in spintronics and opto-electronics field.

  16. Soft antiphase tilt of oxygen octahedra in the hybrid improper multiferroic Ca3Mn1.9Ti0.1O7

    Science.gov (United States)

    Ye, Feng; Wang, Jinchen; Sheng, Jieming; Hoffmann, C.; Gu, T.; Xiang, H. J.; Tian, Wei; Molaison, J. J.; dos Santos, A. M.; Matsuda, M.; Chakoumakos, B. C.; Fernandez-Baca, J. A.; Tong, X.; Gao, Bin; Kim, Jae Wook; Cheong, S.-W.

    2018-01-01

    We report a single crystal neutron and x-ray diffraction study of the hybrid improper multiferroic Ca3Mn1.9Ti0.1O7 (CMTO), a prototypical system where the electric polarization arises from the condensation of two lattice distortion modes. With increasing temperature (T ), the out-of-plane, antiphase tilt of MnO6 decreases in amplitude while the in-plane, in-phase rotation remains robust and experiences abrupt changes across the first-order structural transition. Application of hydrostatic pressure (P ) to CMTO at room temperature shows a similar effect. The consistent behavior under both T and P reveals the softness of antiphase tilt and highlights the role of the partially occupied d orbital of the transition-metal ions in determining the stability of the octahedral distortion. Polarized neutron analysis indicates the symmetry-allowed canted ferromagnetic moment is less than the 0.04 μB/Mn site, despite a substantial out-of-plane tilt of the MnO6 octahedra.

  17. Detection of prostate carcinomas with T1-weighted dynamic contrast-enhanced MRI. Value of two-compartment model; Detektion von Prostatakarzinomen mit T1-gewichteter Kontrastmittel-unterstuetzter dynamischer MRT. Wertigkeit des Zweikompartimentemodells

    Energy Technology Data Exchange (ETDEWEB)

    Kiessling, F.; Lichy, M.; Farhan, N.; Delorme, S.; Kauczor, H.U. [Abteilung fuer Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Grobholz, R. [Abteilung fuer Pathologie, Universitaetsklinikum Mannheim (Germany); Heilmann, M. [Abteilung fuer Physik in der Radiologie, Deutsches Krebsforschungszentrum (DKFZ) Heidelberg (Germany); Michel, M.S.; Trojan, L. [Abteilung fuer Urologie, Universitaetsklinikum Mannheim (Germany); Werner, A.; Rabe, J. [Institut fuer Klinische Radiologie, Universitaetsklinikum Mannheim (Germany); Schlemmer, H.P. [Abteilung fuer Diagnostische Radiologie, Universitaetsklinikum Tuebingen (Germany)

    2003-06-01

    Aim The suitability of dynamic parameters of the two-compartment model for detecting prostate carcinomas and its correlation with tumor microvascular density were evaluated. The study included 43 patients with biopsy-proven prostate carcinoma: 28 were examined by 1.0-T MRI (Turbo-FLASH) and 15 by 1.5-T MRI (FLASH) with infusion of 0.1 mmol/kg Gd-DTPA. Signal time curves were parametrized with an open two-compartment model in amplitude and exchange rate constants (k{sub ep}).The microvascular density of resected prostate carcinomas was determined. The microvascular density in the tumors was significantly higher than in the adjacent healthy prostate tissue and correlated in both sequences with k{sub ep}. Prostate carcinomas of the peripheral zone were demarcated by amplitude and k{sub ep}. In the Turbo-FLASH sequence there was a significant difference between the tumor tissue and healthy peripheral zone in terms of k{sub ep} and in the FLASH sequence in terms of amplitude. Prostate carcinomas can be visualized with dynamic T1-weighted MR sequences using a two-compartment model. Moreover, the parameter k{sub ep} reveals the microvascular density in the tumor and can thus provide valuable clinical information for characterizing the tumors. (orig.) [German] Die Eignung dynamischer Parameter des Zweikompartimentemodells zur Erkennung von Prostatakarzinomen und deren Korrelation mit der Tumormikrogefaessdichte wurden evaluiert. 43 Patienten mit bioptisch gesichertem Prostatakarzinom wurden untersucht, 28 mit 1,0 T- (Turbo-FLASH-) und 15 bei 1,5-T-MRT (FLASH) unter Infusion von 0,1 mmol/kg Gd-DTPA. Signal-Zeit-Kurven wurden nach einem offenen Zweikompartimentemodell in Amplitude sowie Austauschratenkonstante (k{sub ep}) parametrisiert. An resezierten Prostatakarzinomen wurde die Mikrogefaessdichte bestimmt.Ergebnisse Die Mikrogefaessdichte in den Tumoren war signifikant hoeher als im angrenzenden gesunden Prostatagewebe und korrelierte bei beiden Sequenzen mit k{sub ep

  18. Heavy carriers, non-drude optical conductivity and transfer of spectral weight in MnSi

    International Nuclear Information System (INIS)

    Mena, F.P.; Damascelli, A.; Marel, D. van der; Fath, M.; Menovsky, A.A.; Mydosh, J.A.

    2004-01-01

    The optical properties of the weak magnetic metal MnSi were determined using reflectance at 80 deg. (2-800 meV) and ellipsometry (0.8-4.5 eV). At low frequencies in the magnetic phase we observe a departure of the optical conductivity from Drude behavior: m*(ω)/m is strongly frequency dependent and 1/τ(ω) is approximately linear in frequency. In fact, we show that σ(ω)/σ(0)=(1+iω/Γ) -0.5 . Moreover, in the magnetic phase, the plasma frequency shifts to the red indicating that spectral weight is transferred to high frequencies. This is opposite to the effect recently seen in other magnetic compounds

  19. Magnetic phase transitions and magnetocaloric effect of MnCoGe{sub 1−x}Si{sub x}

    Energy Technology Data Exchange (ETDEWEB)

    Lai, J.W.; Zheng, Z.G.; Montemayor, R.; Zhong, X.C.; Liu, Z.W.; Zeng, D.C., E-mail: medczeng@scut.edu.cn

    2014-12-15

    Here a cheaper alternative magnetic refrigeration material using MnCoGe{sub 1−x}Si{sub x} (x=0, 0.1, 0.3, and 0.5) alloys were investigated. The polycrystalline MnCoGe{sub 1−x}Si{sub x} alloys were prepared by arc-melting followed by annealing at 1123 K for 72 h. At a 0.5 at% Si substitution, the Curie temperatures increased by 10% to 374 K, the magnetic entropy change (|ΔS{sub M}|) values decreased by 32% to 2.1 J kg{sup −1} K{sup −1} in an applied field from 0 to 2 T and by 24% to 4.4 J kg{sup −1} K{sup −1} in an applied field from 0 to 5 T. However, the refrigeration capacity (RC{sub FWHM}) of this MnCoGe{sub 0.5}Si{sub 0.5} alloy improved by 27% to 282 J kg{sup −1} and the operation temperature range (δT{sub FWHM}) improved by 92% to 96 K in an applied field at 5 T. The MnCoGe{sub 0.5}Si{sub 0.5} alloy can compete with some of the MCE properties of the MnCo{sub 0.95}Ni{sub 0.05}Ge, LaFe{sub 11}Al{sub 2}C{sub 0.5}, (Fe{sub 85}Co{sub 5}Cr{sub 10}){sub 91}Zr{sub 7}B{sub 2}, and even the Gd{sub 5}Si{sub 2}Ge{sub 2} alloys. The broad operation temperature range (96 K) at a higher Curie temperature (374 K) suggests that the MnCoGe{sub 0.5}Si{sub 0.5} alloy can become a cheaper alternative MCE material (costing 70% less than a MnCoGe alloy). - Highlights: • The economic Si substitutes the noble metal Ge and broadens temperature span(96 K). • The T{sub C} arises when increasing Si in higher room temperature range, 340–374 K. • High thermal stability make them attractive for service temperature of above 300 K. • When Si increases, ΔS{sub M} decreases slightly due to the spontaneous magnetization M{sub S}. • The superior refrigerant capacity indicates that Si substitution benefits the MCE.

  20. AC susceptibility, XRD and DSC studies of Sm1-xGdxMn2Si2 silicides

    International Nuclear Information System (INIS)

    Kervan, S.; Kilic, A.; Gencer, A.

    2004-01-01

    X-ray powder diffraction, AC susceptibility and differential scanning calorimetry (DSC) studies were performed on the polycrystalline Sm 1-x Gd x Mn 2 Si 2 (0≤x≤1) compounds. All compounds investigated crystallize in the body-centered tetragonal ThCr 2 Si 2 -type structure with the space group I4/mmm. Substitution of Gd for Sm leads to a linear decrease of the lattice constants and the unit cell volume. The lattice constants and the unit cell volume obey Vegard's law. At low temperatures, the rare earth sublattice orders and reconfigures the ordering in the Mn sublattice. The samples with x=0.6 and 0.8 exhibit spin reorientation phenomenon. The Neel temperature T N (Mn) determined by DSC technique and the Curie temperature T C (RE) increase linearly with increasing Gd content x. The results are summarized in the x-T magnetic phase diagram

  1. Contrast-enhanced 3T MR perfusion of musculoskeletal tumours. T1 value heterogeneity assessment and evaluation of the influence of T1 estimation methods on quantitative parameters

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Verbizier, Jacques de; Blum, Alain [Hopital Central, CHRU-Nancy, Service d' Imagerie Guilloz, Nancy (France); Chen, Bailiang; Beaumont, Marine [Universite de Lorraine, Laboratoire IADI, UMR S 947, Nancy (France); Badr, Sammy; Cotten, Anne [CHRU Lille Centre de Consultations et d' Imagerie de l' Appareil Locomoteur, Department of Radiology and Musculoskeletal Imaging, Lille (France)

    2017-12-15

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. (orig.)

  2. Elucidation of the enhanced ferromagnetic origin in Mn-doped ZnO nanocrystals embedded into a SiO₂ matrix

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sejoon; Lee, Youngmin; Kim, Deukyoung [Dongguk University, Seoul (Korea, Republic of)

    2013-01-01

    The origin of the enhanced room temperature ferromagnetism in Mn-doped ZnO (ZnO:Mn) nanocrystals is investigated. ZnO:Mn nanocrystals, which were fabricated by using a laser irradiation method with a 248-nm KrF excimer laser, exhibited two-times increase in the spontaneous magnetization (∼0.4 emu/cm³ at 300 K) compared to the ZnO:Mn thin film (∼0.2 emu/cm³ at 300 K). The increased exchange integral of J₁/k{sub B} = 51.6 K in ZnO:Mn nanocrystals, in comparison with the ZnO:Mn thin film (J₁/k{sub B} = 46.9 K), is indicative of the enhanced ferromagnetic exchange interaction. This is attributed to the large number of acceptor defects in the SiO₂-capped ZnO:Mn nanocrystals. Namely, the holes bound to the acceptor defects form microscopic bound-magnetic-polarons with Mn ions; hence, long-range ferromagnetic coupling is enhanced. The results suggest that ferromagnetism in ZnO-based dilute magnetic semiconductors can be controlled by modulating the density of native point defects, which can be chemically and thermodynamically modified during the material synthesis or preparation.

  3. L1{sub 0} stacked binaries as candidates for hard-magnets. FePt, MnAl and MnGa

    Energy Technology Data Exchange (ETDEWEB)

    Matsushita, Yu-ichiro [Max-Planck Institut fuer Microstrukture Physics, Halle (Germany); Department of Applied Physics, The University of Tokyo (Japan); Madjarova, Galia [Max-Planck Institut fuer Microstrukture Physics, Halle (Germany); Department of Physical Chemistry, Faculty of Chemistry and Pharmacy, Sofia University (Bulgaria); Flores-Livas, Jose A. [Department of Physics, Universitaet Basel (Switzerland); Dewhurst, J.K.; Gross, E.K.U. [Max-Planck Institut fuer Microstrukture Physics, Halle (Germany); Felser, C. [Max Planck Institute for Chemical Physics of Solids, Dresden (Germany); Sharma, S. [Max-Planck Institut fuer Microstrukture Physics, Halle (Germany); Department of Physics, Indian Institute of Technology, Roorkee, Uttarkhand (India)

    2017-08-15

    We present a novel approach for designing new hard magnets by forming stacks of existing binary magnets to enhance the magneto crystalline anisotropy. This is followed by an attempt at reducing the amount of expensive metal in these stacks by replacing it with cheaper metal with similar ionic radius. This strategy is explored using examples of FePt, MnAl and MnGa. In this study a few promising materials are suggested as good candidates for hard magnets: stacked binary FePt{sub 2}MnGa{sub 2} in structure where each magnetic layer is separated by two non-magnetic layers, FePtMnGa and FePtMnAl in hexagonally distorted Heusler structures and FePt{sub 0.5}Ti{sub 0.5}MnAl. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Structural, magnetic and transport properties of Mn3.1Sn0.9 and Mn3.1Sn0.9N compounds

    International Nuclear Information System (INIS)

    Feng, W.J.; Li, D.; Ren, W.J.; Li, Y.B.; Li, W.F.; Li, J.; Zhang, Y.Q.; Zhang, Z.D.

    2007-01-01

    The cubic anti-perovskite Mn 3.1 Sn 0.9 N compound is prepared via nitrogenation of the hexagonal Mn 3.1 Sn 0.9 compound. A magnetic phase diagram of Mn 3.1 Sn 0.9 compound is constructed by analysis of data of its magnetic properties. For Mn 3.1 Sn 0.9 N compound, parasitic ferromagnetism exists in the temperature range of 5-370 K, besides a spin-reorientation at about 280 K. Mn 3.1 Sn 0.9 compound exhibits a metallic conducting behavior, while Mn 3.1 Sn 0.9 N displays a metal-nonmetal transition due to the electron localization caused by the static disorder. The differences of the physical properties between the both compounds, are discussed, in terms of the correlation of the hexagonal DO 19 and the cubic anti-perovskite structures, the reduction of the distances between Mn atoms, and the spin-pairing or charge transfer effect due to the electron donation by N 2p to Mn 3d states after introduction of N atoms into the interstitial sites of Mn 3.1 Sn 0.9 compound

  5. Structural and magnetic properties of MnCo1-xVxGe compounds

    International Nuclear Information System (INIS)

    Meng, G.H.; Tegus, O.; Zhang, W.G.; Song, L.; Huang, J.H.

    2010-01-01

    The structural and magnetic properties of MnCo 1-x V x Ge (x = 0.00, 0.02, 0.04, 0.06, 0.08, 0.10, 0.20 and 0.30) compounds were investigated by means of X-ray diffraction, scanning electron microscopy and magnetization measurements. The MnCo 1-x V x Ge compounds crystallize in the orthorhombic TiNiSi-type crystal structure for x ≤ 0.02 and in the hexagonal Ni 2 In-type structure for x > 0.02. The magnetization measurements show that the MnCo 1-x V x Ge compounds exhibit a complex magnetic behavior. The Curie temperature can be tuned from 360 K to 148 K by increasing x. The maximal magnetic-entropy change is 3.9 J/kg K for x = 0.06 at a field change from 0 to 1.5 T at about 265 K.

  6. Magnetic resonance imaging of pelvic entheses - a systematic comparison between short tau inversion recovery (STIR) and T1-weighted, contrast-enhanced, fat-saturated sequences

    International Nuclear Information System (INIS)

    Klang, Eyal; Aharoni, Dvora; Rimon, Uri; Eshed, Iris; Hermann, Kay-Geert; Herman, Amir; Shazar, Nachshon

    2014-01-01

    To assess the contribution of contrast material in detecting and evaluating enthesitis of pelvic entheses by MRI. Sixty-seven hip or pelvic 1.5-T MRIs (30:37 male:female, mean age: 53 years) were retrospectively evaluated for the presence of hamstring and gluteus medius (GM) enthesitis by two readers (a resident and an experienced radiologist). Short tau inversion recovery (STIR) and T1-weighted pre- and post-contrast (T1+Gd) images were evaluated by each reader at two sessions. A consensus reading of two senior radiologists was regarded as the gold standard. Clinical data was retrieved from patients' referral form and medical files. Cohen's kappa was used for intra- and inter-observer agreement calculation. Diagnostic properties were calculated against the gold standard reading. A total of 228 entheses were evaluated. Gold standard analysis diagnosed 83 (36 %) enthesitis lesions. Intra-reader reliability for the experienced reader was significantly (p = 0.0001) higher in the T1+Gd images compared to the STIR images (hamstring: k = 0.84/0.45, GM: k = 0.84/0.47). Sensitivity and specificity increased from 0.74/0.8 to 0.87/0.9 in the STIR images and T1+Gd sequences. Intra-reader reliability for the inexperienced reader was lower (p > 0.05). Evidence showing that contrast material improves the reliability, sensitivity, and specificity of detecting enthesitis supports its use in this setting. (orig.)

  7. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  8. Signal-shot echo-planner diffusion-weighted MR imaging at 3T and 1.5T for differentiation of benign vertebral fracture edema and tumor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-09-15

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  9. Enhancement of exchange coupling interaction of NdFeB/MnBi hybrid magnets

    Science.gov (United States)

    Nguyen, Truong Xuan; Nguyen, Khanh Van; Nguyen, Vuong Van

    2018-03-01

    MnBi ribbons were fabricated by melt - spinning with subsequent annealing. The MnBi ribbons were ground and mixed with NdFeB commercial Magnequench powders (MQA). The hybrid powder mixtures were subjected thrice to the annealing and ball-milling route. The hybrid magnets (100 - x)NdFeB/xMnBi, x=0, 30, 40, 50 and 100 wt% were in-mold aligned in an 18 kOe magnetic field and warm compacted at 290 °C by 2000 psi uniaxial pressure for 10 min. An enhancement of the exchange coupling of NdFeB/MnBi hybrid magnets was obtained by optimizing the magnets' microstructures via annealing and ball-milling processes. The magnetic properties of prepared NdFeB/MnBi hybrid magnets were studied and discussed in details.

  10. Enhanced magnetoresistance in La0.7Ca0.3Mn03/Nd0.7Ca0.3Mn03 epitaxial multilayers

    International Nuclear Information System (INIS)

    Sharma, Himanshu; Khan, Md. S.; Tomy, C.V.; Jain, Sourabh; Tulapurkar, Ashwin

    2014-01-01

    Magnanite multilayers of La 0.7 Ca 0.3 MnO 3 /Nd 0.7 Ca 0.5 MnO 3 have been fabricated on SrTiO 3 (100) substrate using Nd 0.7 Ca 0.5 MnO 3 as the spacer layers. An enhanced magnetoresistance (MR) of more than 80% is observed in the multilayers compared with LCMO thin film (∼50%). Result suggests that the interface strains between LCMO and NCMO layers may have influences on the transport properties and a suitable film structure could be used to increase the large low field magnetoresistance. (author)

  11. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  12. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  13. T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-06-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as "intensity field bias". Such inhomogeneities mostly originate from heterogeneous RF coil B(1) profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T(1)-weighted (T(1)w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T(1) weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T(1) contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B(1) variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B(1) profiles become more heterogeneous. Another characteristic of T(1)w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T(2)(*) contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T(1)w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T(2)(*) contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 T, provide higher T(1) contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help in identifying small brain structures and that T(2)(*) induced artifacts can be removed from the images. The resulting unbiased T(1)w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T(1)w structural images. In addition

  14. The value of T1-weighted images in the differentiation between MS, white matter lesions, and subcortical arteriosclerotic encephalopathy (SAE)

    Energy Technology Data Exchange (ETDEWEB)

    Uhlenbrock, D.; Sehlen, S.

    1989-07-01

    The aim of the study was to define reliable criteria for the differentiation of MR imaging between patients with MS and with 'vascular' white matter lesions/SAE. We examined 35 patients with proven MS according to the Poser criteria and 35 patients with other white matter lesions and/or SAE. The result is that with MR a differentiation can be achieved provided that T1-weighted spin-echo sequences are included and the different pattern of distribution is considered. MS plaques are predominantly located in the subependymal region, vascular white matter lesions are mainly located in the water-shed of the superficial middle cerebral branches and the deep perforating long medullary vessels in the centrum semiovale. Infratentorial lesions are more often seen in MS. Confluence at the lateral ventricles is frequently accompanied by confluent abnormalities around the third ventricle, Sylvian aqueduct, and fourth ventricle, which is uncommon in SAE. In MS many lesions visible on T2-weighted images have a cellular or intracellular composition that renders them visible also on T1-weighted ones as regions with low signal intensity and more or less distinct boundary. 'Vascular' white matter lesions and SAE mainly represent demyelination and can therefore be seen on T2-weighted images, but corresponding low signal intensity lesions on T1-weighted images are uncommon. In some exceptions there are such lesions with low signal representing lacunar infarcts or widened Virchow-Robin-spaces. (orig.).

  15. Detection of cortical architecture of rat brain using high-resolution 7.0 T manganese-enhanced MRI in vivo

    International Nuclear Information System (INIS)

    Wen Song; Gao Gejun; Yu Hui; Yang Tao; Dai Feng; Yan Lihui; An Yanli; Zang Fengchao

    2010-01-01

    Objective: To study the role of manganese-enhanced MRI (MEMRI) in the depiction of cortical architecture of rat brain after systemic administration of Mn 2+ through caudal vein and compare the effects of normal or opened blood-brain barrier on the manganese-enhanced MRI. Methods: Fifteen SD rats were randomly divided into three groups according to ranked list of random. Blood-brain barrier was opened in short time by the injection of 30% mannitol via the right internal carotid artery in group A, then 100 mmol/L MnCl 2 physiologic saline solution was delivered through vena caudalis, and MRI was performed 12 hours later.. In group B, 100 mmol/L MnCl 2 physiologic saline solutions was administrated through vena caudalis, following normal saline injection into the right internal carotid artery, and MRI was performed 12 hours later. The group C served as normal control group. All images were acquired with a 7.0 T micro MR scanner. Signal-to-noise ratios (SNR) in regions of interest were measured by Paravision 4.0 and the differences of three groups were compared by using one-way ANOVA. The differences of SNR on both sides of hemispheres were compared by using paired t test. Results: MEMRI could show the gray matter and white matter of rat brain and the anatomy borders between somatosensory cortex and motor cortex clearly. Periventricular structures such as hippocampus, dentate gyrus, habenula united, and olfactory bulb could also be showed clearly. Symmetrical enhancement on both sides of the cortex and banded structures was shown clearly in group B. The SNR increased and t he differences were significant in right cerebral cortex, both sides of cerebellar cortex, hippocampus and pituitary among three groups (right cerebral cortex 35.2 ± 7.0, 30.1 ± 2.4, 26.6 ± 2.8, F=4.36, P=0.038; left cerebellar cortex 27.1 ± 5.2, 29.4 ± 3.8, 19.4 ± 4.5, F=6.66, P=0.011; right cerebellar cortex 27.8 ± 3.8, 28.5 ± 4.2, 20.4 ± 4.8, F=5.84, P=0.017; left hippocampus 34.5 ± 4

  16. Quantitative analysis of hyperintensity rim sign surrounding MS plaque on T1 weighted images. Comparison with lacunar infarction

    International Nuclear Information System (INIS)

    Komura, Shinji; Ozaki, Yutaka

    2008-01-01

    This study evaluated the incidence of MR findings showing a hyperintensity rim surrounding multiple sclerosis (MS) plaque on T1-weighted images using image analysis software. We also evaluate the efficacy of this MR finding for differentiating between MS and lacunar infarction. We reviewed T1-weighted images in clinically diagnosed MS patients who underwent MR imaging between February 2006 and July 2007. Two hundred and thirty-nine nodular low signal intensities over 5 mm in minimal diameter were observed in 39 MS patients. To compare the incidence of MR findings, we also reviewed T1-weighted images in randomly selected lacunar infarction patients who underwent MR imaging during the same period. There were 51 nodular low signal intensities over 5 mm in shortest diameter in 34 lacunar infarction patients. After standardization of MR images, we calculated each signal intensity at the plaque margin (M.I.) and surrounding white matter (Wh.I.) using plot-profile analysis. We judged that hyperintensity rim sign was positive when the M.I/Wh.I. ratio was over 1.05. Among 239 T1 low intensity plaques in 39 MS patients, hyperintensity rim sign was positive for 81 (33.9%) plaques in 21 (53.8%) patients. Among 51 T1 low intensity lesions in 34 lacunar infarction patients, hyperintensity rim sign was positive for only one lesion in one patient. There were significant differences in the incidence of hyperintensity rim sign between the two patients groups (p<0.0001). On quantitative analysis using imaging standardization and plot-profile analysis, hyperintensity rim sign was observed in one-third of T1 low intensity MS plaques. This finding seems to be useful to differentiate multiple sclerosis from lacunar infarction. (author)

  17. Monodispersed MnO nanoparticles with epitaxial Mn{sub 3}O{sub 4} shells

    Energy Technology Data Exchange (ETDEWEB)

    Berkowitz, A E; Rodriguez, G F [Department of Physics, University of California, San Diego La Jolla, CA 92093 (United States); Hong, J I; Fullerton, E E [Center for Magnetic Recording Research, University of California-San Diego La Jolla, CA 92093 (United States); An, K; Hyeon, T [National Creative Research Initiative Center for Oxide Nanocrystalline Materials, Seoul National University, Seoul 151-744 (Korea, Republic of); Agarwal, N; Smith, D J [School of Materials and Department of Physics, Arizona State University, Tempe, AZ 85287 (United States)

    2008-07-07

    We report the microstructural and magnetic properties of monodispersed nanoparticles (NPs) of antiferromagnetic MnO (T{sub N} = 118 K), with epitaxial ferrimagnetic Mn{sub 3}O{sub 4} (T{sub C} = 43 K) shells. Above T{sub C}, an unusually large magnetization is present, produced by the uncompensated spins (UCSs) on the surface of the MnO particles. These spins impart a net anisotropy to the MnO particles that is approximately three orders of magnitude larger than the bulk value. As a result, an anomalously high blocking temperature is exhibited by the MnO particles, and finite coercivity and exchange bias are present above T{sub C}. When field cooled below T{sub C}, a strong exchange bias was established in the Mn{sub 3}O{sub 4} shells as a result of high net anisotropy of the MnO particles. A large coercivity was also observed. Models of several aspects of the behaviour of this unusual system emphasized the essential role of the UCSs on the surfaces of the MnO NPs.

  18. Gd-DTPA-enhanced MR imaging in meningitis

    International Nuclear Information System (INIS)

    Han, M.H.; Chang, K.H.; Roh, J.K.; Kim, I.O.; Han, M.C.; Kim, C.W.

    1988-01-01

    Gd-DPTA-enhanced MR imaging was performed in 16 patients with meningitis (seven tuberculous, four bacterial, three fungal, and two viral) on a 2.0-T unit. Hemorrhagic infarcts of basal ganglia and localized enhancement of thickened dura adjacent were demonstrated on T1-weighted images in three patients with tuberculous meningitis and four with bacterial meningitis, respectively, that were not seen on CT. Enhanced T1-weighted images readily differentiated leptomeningeal enhancement from vessels in two cases with CT of equivocal meningeal enhancement. Nonenhanced T2-weighted images were most sensitive for demonstrating ischemia/infarct and edema. Otherwise, MR images generally matched CT scans

  19. Synthesis, microstructure and EPR of CaMnO3 and EuxCa1-xMnO3 manganite, obtained by coprecipitation

    International Nuclear Information System (INIS)

    Santiago T, M.; Hernandez C, L.; Legorreta G, F.; Montiel S, H.; Alvarez L, G.; Flores G, M. A.

    2011-01-01

    The synthesis of CaMnO 3 and Eu x Ca 1-x MnO 3 obtained by coprecipitation method is showed. The synthesized samples were characterized by X-ray diffraction and scanning electronic microscopy, the powders showed orthorhombic structure and pnma space group. When it was doped with Europium, their morphology tendency was spherical. Measurements were carried out on electron paramagnetic resonance (EPR) with constant frequency = 9.4 GHz (band X) and dc magnetic field (H dc) 0-0.8 T, measurements were at 300 K and 77 K. EPR spectra showed significant differences between both samples, indicating that the substitution of divalent alkaline earth cations by trivalent rare earth ions, allowing the formation of a mixed valence state of manganese, Mn 3+ and Mn 4+ . A 77 K, the manganite of concentration x = 0.30 had a magnetic ordering, noted by the presence of hysteresis. (Author)

  20. Assessing liver function in patients with HBV-related HCC: a comparison of T{sub 1} mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Ying; Rao, Sheng-Xiang; Chen, Caizhong; Li, Renchen; Zeng, Meng-Su [Zhongshan Hospital of Fudan University, Department of Radiology, 180 Fenglin Road, Xuhui District, Shanghai (China)

    2015-05-01

    To compare the potential of T{sub 1} mapping on gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) for assessing liver function in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). One hundred consecutive patients with known HBV-related HCCs were included. T{sub 1} relaxation time and apparent diffusion coefficient (ADC) of the liver were measured, and the reduction rate of T{sub 1} relaxation time (∇%) was calculated. T{sub 1} relaxation time measurements were compared with ADC values according to the Model for End-Stage Liver Disease (MELD) score. Hepatobiliary phase (HBP) and ∇% of T{sub 1} relaxation time measurements showed significant correlations with MELD score (rho = 0.571, p < 0.0001; rho = -0.573, p < 0.0001, respectively). HBP and ∇% of T{sub 1} relaxation time were significantly different between good (MELD ≤8) and poor liver function (MELD ≥9) (p < 0.0001 for both). Areas under the receiver operating characteristic curves (AUCs) of T{sub 1} relaxation time for HBP (AUC 0.84) and ∇% (AUC 0.82) were significantly better than for ADC (AUC 0.53; p < 0.0001). T{sub 1} mapping on Gd-EOB-DTPA-enhanced MRI showed promise for evaluating liver function in patients with HBV-related HCC, while DWI was not reliable. HBP T{sub 1} relaxation time measurement was equally accurate as ∇% measurement. (orig.)

  1. T1 weighted Brain Images at 7 Tesla Unbiased for Proton Density, T2* contrast and RF Coil Receive B1 Sensitivity with Simultaneous Vessel Visualization

    Science.gov (United States)

    Van de Moortele, Pierre-François; Auerbach, Edwards J.; Olman, Cheryl; Yacoub, Essa; Uğurbil, Kâmil; Moeller, Steen

    2009-01-01

    At high magnetic field, MR images exhibit large, undesirable signal intensity variations commonly referred to as “intensity field bias”. Such inhomogeneities mostly originate from heterogeneous RF coil B1 profiles and, with no appropriate correction, are further pronounced when utilizing rooted sum of square reconstruction with receive coil arrays. These artifacts can significantly alter whole brain high resolution T1-weighted (T1w) images that are extensively utilized for clinical diagnosis, for gray/white matter segmentation as well as for coregistration with functional time series. In T1 weighted 3D-MPRAGE sequences, it is possible to preserve a bulk amount of T1 contrast through space by using adiabatic inversion RF pulses that are insensitive to transmit B1 variations above a minimum threshold. However, large intensity variations persist in the images, which are significantly more difficult to address at very high field where RF coil B1 profiles become more heterogeneous. Another characteristic of T1w MPRAGE sequences is their intrinsic sensitivity to Proton Density and T2* contrast, which cannot be removed with post-processing algorithms utilized to correct for receive coil sensitivity. In this paper, we demonstrate a simple technique capable of producing normalized, high resolution T1w 3D-MPRAGE images that are devoid of receive coil sensitivity, Proton Density and T2* contrast. These images, which are suitable for routinely obtaining whole brain tissue segmentation at 7 Tesla, provide higher T1 contrast specificity than standard MPRAGE acquisitions. Our results show that removing the Proton Density component can help identifying small brain structures and that T2* induced artifacts can be removed from the images. The resulting unbiased T1w images can also be used to generate Maximum Intensity Projection angiograms, without additional data acquisition, that are inherently registered with T1w structural images. In addition, we introduce a simple technique

  2. Electrochemically active MnO{sub 2} coated Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2} cathode with highly improved initial coulombic efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Yanling; Xu, Youlong, E-mail: ylxu@mail.xjtu.edu.cn; Sun, Xiaofei; Xiong, Lilong; Mao, Shengchun

    2016-10-30

    Highlights: • MnO{sub 2} was used to coat lithium-rich layered oxide Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2}. • MnO{sub 2} is electrochemically active and became spinel phase after cycles. • MnO{sub 2}-coated material shows noticeably improved initial coulombic efficiency. • Specific capacities and rate performances could also be enhanced by MnO{sub 2} coating. - Abstract: Lithium-rich layered oxide is known to be one of the most promising positive electrode materials for lithium ion batteries due to its large capacity and high energy density. However, low initial coulombic efficiency is currently an urgent problem hindering its practical application. In this work, electrochemically active MnO{sub 2} coating was used to improve the coulombic efficiency of Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2}. Firstly, the pristine material was synthesized via co-precipitation following by solid-state calcination. Then MnO{sub 2}-coated Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2} was prepared by heat treatment of the mixture of pristine powder and manganese nitrate. During first discharging, lithium ions can intercalate into not only the delithiated Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2} but also the MnO{sub 2} coating, thus noticeably improves the coulombic efficiency and discharge capacity. The initial efficiency is enhanced from 61.2% (pristine) to 84.4%, 88.8% and 95.4%, respectively, for 10 wt.%, 15 wt.% and 20 wt.% MnO{sub 2} coated Li{sub 1.2}Ni{sub 0.18}Co{sub 0.04}Mn{sub 0.58}O{sub 2} at 20 mA g{sup −1}. Furthermore, the 15 wt.% MnO{sub 2} coated sample delivers an initial discharge capacity as high as 294.4 mAh g{sup −1}.

  3. Binding of higher alcohols onto Mn(12) single-molecule magnets (SMMs): access to the highest barrier Mn(12) SMM.

    Science.gov (United States)

    Lampropoulos, Christos; Redler, Gage; Data, Saiti; Abboud, Khalil A; Hill, Stephen; Christou, George

    2010-02-15

    Two new members of the Mn(12) family of single-molecule magnets (SMMs), [Mn(12)O(12)(O(2)CCH(2)Bu(t))(16)(Bu(t)OH)(H(2)O)(3)].2Bu(t)OH (3.2Bu(t)OH) and [Mn(12)O(12)(O(2)CCH(2)Bu(t))(16)(C(5)H(11)OH)(4)] (4) (C(5)H(11)OH is 1-pentanol), are reported. They were synthesized from [Mn(12)O(12)(O(2)CMe)(16)(H(2)O)(4)].2MeCO(2)H.4H(2)O (1) by carboxylate substitution and crystallization from the appropriate alcohol-containing solvent. Complexes 3 and 4 are new members of the recently established [Mn(12)O(12)(O(2)CCH(2)Bu(t))(16)(solv)(4)] (solv = H(2)O, alcohols) family of SMMs. Only one bulky Bu(t)OH can be accommodated into 3, and even this causes significant distortion of the [Mn(12)O(12)] core. Variable-temperature, solid-state alternating current (AC) magnetization studies were carried out on complexes 3 and 4, and they established that both possess an S = 10 ground state spin and are SMMs. However, the magnetic behavior of the two compounds was found to be significantly different, with 4 showing out-of-phase AC peaks at higher temperatures than 3. High-frequency electron paramagnetic resonance (HFEPR) studies were carried out on single crystals of 3.2Bu(t)OH and 4, and these revealed that the axial zero-field splitting constant, D, is very different for the two compounds. Furthermore, it was established that 4 is the Mn(12) SMM with the highest kinetic barrier (U(eff)) to date. The results reveal alcohol substitution as an additional and convenient means to affect the magnetization relaxation barrier of the Mn(12) SMMs without major change to the ligation or oxidation state.

  4. Magnetic properties of NdMn{sub 1−x}Fe{sub x}O{sub 3+δ} (0≤x≤0.3) system

    Energy Technology Data Exchange (ETDEWEB)

    Mihalik, Matúš, E-mail: matmihalik@saske.sk [Institute of Experimental Physics SAS, Watsonova 47, 040 01 Košice (Slovakia); Mihalik, Marián [Institute of Experimental Physics SAS, Watsonova 47, 040 01 Košice (Slovakia); Fitta, M.; Bałanda, M. [Institute of Nuclear Physics Polish Academy of Sciences, Radzikowskiego 152, 31-342 Kraków (Poland); Vavra, M. [Institute of Experimental Physics SAS, Watsonova 47, 040 01 Košice (Slovakia); P.J. Šafárik University, Moyzesova 11, 041 54 Košice (Slovakia); Gabáni, S.; Zentková, M. [Institute of Experimental Physics SAS, Watsonova 47, 040 01 Košice (Slovakia); Briančin, J. [Institute of Geotechnics SAS, Watsonova 45, 043 53 Košice (Slovakia)

    2013-11-15

    We have studied the effect of Fe for Mn substitution on magnetic properties of NdMn{sub 1−x}Fe{sub x}O{sub 3+δ} compounds. Our heat capacity, AC susceptibility and magnetization measurements revealed that the transition from paramagnetic to magnetically ordered state of the Mn sublattice decreases linearly from T{sub N}=74.9 K to T{sub N}=49 K with doping up to x=0.25. The ordering temperature T{sub 1} of Nd sublattice varies in a non-monotonous way in the temperature range 11–16 K. For x=0.3, the ordering of the Mn/Fe sublattice is residual, while the magnetism in Nd sublattice seems to be intact. The broad maximum in heat capacity C(T) at about 10 K was ascribed by 2-level Schottky contribution (Δ=21(1) K) for x=0, but this description failed for Fe-doped samples. An upturn of C(T) at temperatures below 0.5 K was observed on NdMnO{sub 3} and can be accounted to nuclear contribution. A more detailed study of AC susceptibility performed on samples with x=0.1 and 0.2 revealed a shift of both peaks to higher temperature with increasing frequency. The compensation temperature and a large negative field-cooled magnetization was observed for concentrations x=0.2 and x=0.25. - Highlights: • Fe substitution into NdMnO{sub 3} compound decreases T{sub N} by 10 K for 10% of Fe. • In this compound: Nd and Mn ions both order magnetically. • “Butterfly-type” hysteresis loops in the ordered state.

  5. Enhanced Ferromagnetism in Nanoscale GaN:Mn Wires Grown on GaN Ridges.

    Science.gov (United States)

    Cheng, Ji; Jiang, Shengxiang; Zhang, Yan; Yang, Zhijian; Wang, Cunda; Yu, Tongjun; Zhang, Guoyi

    2017-05-02

    The problem of weak magnetism has hindered the application of magnetic semiconductors since their invention, and on the other hand, the magnetic mechanism of GaN-based magnetic semiconductors has been the focus of long-standing debate. In this work, nanoscale GaN:Mn wires were grown on the top of GaN ridges by metalorganic chemical vapor deposition (MOCVD), and the superconducting quantum interference device (SQUID) magnetometer shows that its ferromagnetism is greatly enhanced. Secondary ion mass spectrometry (SIMS) and energy dispersive spectroscopy (EDS) reveal an obvious increase of Mn composition in the nanowire part, and transmission electron microscopy (TEM) and EDS mapping results further indicate the correlation between the abundant stacking faults (SFs) and high Mn doping. When further combined with the micro-Raman results, the magnetism in GaN:Mn might be related not only to Mn concentration, but also to some kinds of built-in defects introduced together with the Mn doping or the SFs.

  6. Methods of fetal MR: beyond T2-weighted imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Stuhr, Fritz; Lindner, Christian; Prayer, Daniela

    2006-01-01

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body

  7. Methods of fetal MR: beyond T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Stuhr, Fritz [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Lindner, Christian [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body.

  8. Pre-treatment functional MRI of breast cancer: T2* evaluation at 3 T and relationship to dynamic contrast-enhanced and diffusion-weighted imaging.

    Science.gov (United States)

    Kousi, Evanthia; O'Flynn, Elizabeth A M; Borri, Marco; Morgan, Veronica A; deSouza, Nandita M; Schmidt, Maria A

    2018-05-31

    Baseline T2* relaxation time has been proposed as an imaging biomarker in cancer, in addition to Dynamic Contrast-Enhanced (DCE) MRI and diffusion-weighted imaging (DWI) parameters. The purpose of the current work is to investigate sources of error in T2* measurements and the relationship between T2* and DCE and DWI functional parameters in breast cancer. Five female volunteers and thirty-two women with biopsy proven breast cancer were scanned at 3 T, with Research Ethics Committee approval. T2* values of the normal breast were acquired from high-resolution, low-resolution and fat-suppressed gradient-echo sequences in volunteers, and compared. In breast cancer patients, pre-treatment T2*, DCE MRI and DWI were performed at baseline. Pathologically complete responders at surgery and non-responders were identified and compared. Principal component analysis (PCA) and cluster analysis (CA) were performed. There were no significant differences between T2* values from high-resolution, low-resolution and fat-suppressed datasets (p > 0.05). There were not significant differences between baseline functional parameters in responders and non-responders (p > 0.05). However, there were differences in the relationship between T2* and contrast-agent uptake in responders and non-responders. Voxels of similar characteristics were grouped in 5 clusters, and large intra-tumoural variations of all parameters were demonstrated. Breast T2* measurements at 3 T are robust, but spatial resolution should be carefully considered. T2* of breast tumours at baseline is unrelated to DCE and DWI parameters and contribute towards describing functional heterogeneity of breast tumours. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. MR of normal pancreas : comparison of five pulse sequences and enhancing patterns on dynamic imaging

    International Nuclear Information System (INIS)

    Jang, Hyun Jung; Kim, Tae Kyoung; Hong, Sung Hwan; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To compare T1-weighted FLASH and turbo spin echo (SE) T2-weighted sequences with conventional T1- and T2-weighted sequences in imaging normal pancreas and to describe the enhancing patterns on dynamic MR imging. Forty-four patients with presumed hepatic hemangiomas were studied at 1.0T or 1.5T by using conventional SE sequences (T1-weighted, T2-weighted, and heavily T2-weighted), turbo-SE T2-weighted sequences, and breath-hold T1-weighted FLASH sequences acquired before, immediately on, and at 1, 2, 3, and 5 or 10 minutes after injection of a bolus of gadopentetate dimeglumine. No patients had either a history or its clinical features of pancreatic disease. Images were quantitatively analyzed for signal-difference-to noise ratios (SD/Ns) between the pancreas and peripancreatic fat. Percentage enhancement of the pancreas was measured on each dynamic MR image. Conspicuity of the pancreatic border was qualitatively evaluated according to a consensus, reached by three radiologists. Turbo-SE T2-weighted images had a significantly higher SD/N ratio (p<0.001) and better conspicuity of the pancreatic border (p<0.001) than SE T2- and heavily T2-weighted images;T1-weighted SE images had a significantly higher SD/N ratio than T1-weighted FLASH images (p<0.001), but there was no significant difference between tham in qualitative analysis (p=0.346). Percentage enhancement immediately on and at 1, 2, 3, 5, and 10 minutes after administration of contrast material was 39.9%, 44.5%, 42.9%, 40.8%, 36.3%, 29.9%, respectively, with peak enhancement at 1 minute. In MR imaging of normal pancreas, turbo-SE T2-weighted imaging is superior to SE T2- and heavily T2- weighted imaging, and SE T1-weighted imaging is superior to T1-weighted FLASH imaging. On serial gadolinium-enhanced FLASH imaging, normal pancreas shows peak enhancement at 1 minute

  10. Unraveling the Raman Enhancement Mechanism on 1T'-Phase ReS2 Nanosheets.

    Science.gov (United States)

    Miao, Peng; Qin, Jing-Kai; Shen, Yunfeng; Su, Huimin; Dai, Junfeng; Song, Bo; Du, Yunchen; Sun, Mengtao; Zhang, Wei; Wang, Hsing-Lin; Xu, Cheng-Yan; Xu, Ping

    2018-04-01

    2D transition metal dichalcogenides materials are explored as potential surface-enhanced Raman spectroscopy substrates. Herein, a systematic study of the Raman enhancement mechanism on distorted 1T (1T') rhenium disulfide (ReS 2 ) nanosheets is demonstrated. Combined Raman and photoluminescence studies with the introduction of an Al 2 O 3 dielectric layer unambiguously reveal that Raman enhancement on ReS 2 materials is from a charge transfer process rather than from an energy transfer process, and Raman enhancement is inversely proportional while the photoluminescence quenching effect is proportional to the layer number (thickness) of ReS 2 nanosheets. On monolayer ReS 2 film, a strong resonance-enhanced Raman scattering effect dependent on the laser excitation energy is detected, and a detection limit as low as 10 -9 m can be reached from the studied dye molecules such as rhodamine 6G and methylene blue. Such a high enhancement factor achieved through enhanced charge interaction between target molecule and substrate suggests that with careful consideration of the layer-number-dependent feature and excitation-energy-related resonance effect, ReS 2 is a promising Raman enhancement platform for sensing applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Evaluation of multimodal segmentation based on 3D T1-, T2- and FLAIR-weighted images - the difficulty of choosing.

    Science.gov (United States)

    Lindig, Tobias; Kotikalapudi, Raviteja; Schweikardt, Daniel; Martin, Pascal; Bender, Friedemann; Klose, Uwe; Ernemann, Ulrike; Focke, Niels K; Bender, Benjamin

    2018-04-15

    Voxel-based morphometry is still mainly based on T1-weighted MRI scans. Misclassification of vessels and dura mater as gray matter has been previously reported. Goal of the present work was to evaluate the effect of multimodal segmentation methods available in SPM12, and their influence on identification of age related atrophy and lesion detection in epilepsy patients. 3D T1-, T2- and FLAIR-images of 77 healthy adults (mean age 35.8 years, 19-66 years, 45 females), 7 patients with malformation of cortical development (MCD) (mean age 28.1 years,19-40 years, 3 females), and 5 patients with left hippocampal sclerosis (LHS) (mean age 49.0 years, 25-67 years, 3 females) from a 3T scanner were evaluated. Segmentation based on T1-only, T1+T2, T1+FLAIR, T2+FLAIR, and T1+T2+FLAIR were compared in the healthy subjects. Clinical VBM results based on the different segmentation approaches for MCD and for LHS were compared. T1-only segmentation overestimated total intracranial volume by about 80ml compared to the other segmentation methods. This was due to misclassification of dura mater and vessels as GM and CSF. Significant differences were found for several anatomical regions: the occipital lobe, the basal ganglia/thalamus, the pre- and postcentral gyrus, the cerebellum, and the brainstem. None of the segmentation methods yielded completely satisfying results for the basal ganglia/thalamus and the brainstem. The best correlation with age could be found for the multimodal T1+T2+FLAIR segmentation. Highest T-scores for identification of LHS were found for T1+T2 segmentation, while highest T-scores for MCD were dependent on lesion and anatomical location. Multimodal segmentation is superior to T1-only segmentation and reduces the misclassification of dura mater and vessels as GM and CSF. Depending on the anatomical region and the pathology of interest (atrophy, lesion detection, etc.), different combinations of T1, T2 and FLAIR yield optimal results. Copyright © 2017 Elsevier

  12. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  13. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  14. Study of paramagnetic contrast agents for NMR imaging: theoretical and experimental aspects (the case of Mn2+ ion)

    International Nuclear Information System (INIS)

    Chavoix, M.E.

    1984-06-01

    The use of contrast enhancing agents and the evaluation of magnetic properties of tissues, extend the diagnostic usefulness of Nuclear Magnetic Resonance (NMR) imaging. From this point of view, proton T 1 (spin-lattice) relaxation times of rat tissue, following parenteral administration of Mn(II) to increase the relaxation rate (R 1 =1/T 1 ), have been studied at 20 MHz. Differenciation of free (MF) and bound (Mb) manganese in these tissues was thus determined by measuring, total exogenous Mn ++ ions by Atomic Absorption spectrometry and free (non protein complexed) ions by Electron Spin Resonance Analysis. From these results, the diffusion of Mn ++ into various organs, was evaluated 15 min. after injection. A significant difference in the fixation of manganese occured between the liver and the pancreas with uptakes of 50% and 1% of the administration dose respectively [fr

  15. Carbon-Coated Perovskite BaMnO3 Porous Nanorods with Enhanced Electrocatalytic Perporites for Oxygen Reduction and Oxygen Evolution

    International Nuclear Information System (INIS)

    Xu, Yujiao; Tsou, Alvin; Fu, Yue; Wang, Jin; Tian, Jing-Hua; Yang, Ruizhi

    2015-01-01

    A thin carbon layer has been introduced to coat on the perovskite BaMnO 3 nanorods by a facile method, which exhibit significantly enhanced electrocatalytic activity for both the ORR and OER with excellent stability. - Highlights: • A non-rare-earth element based perovskite BaMnO 3 nanorods as an active electrocatalyst for the ORR and OER have been prepared and investigated for the first time. • A thin carbon-coating layer with thickness of approximately 10 nm has been successfully introduced to enhance the electrical conductivity and the electrocatalytic activities of the bare perovskite for both ORR and OER. • The stabilities of bare BaMnO 3 nanorods for both ORR and OER have also been improved dramatically with the help of carbon coating, especially for the OER process. - Abstract: Highly efficient, low-cost catalysts, especially with bifunctional electrocatalytic capabilities for both the oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) are vital for the wide commercialization of fuel cells and metal-air batteries. In this study, BaMnO 3 - a non-rare-earth element based perovskite nanorods have been prepared and investigated for the first time, and a thin carbon-coating with a thickness of approximately 10 nm has been successfully introduced to enhance the electrical conductivity of the bare perovskite. Electrochemical tests reveal that bare BaMnO 3 nanorods exhibit very good catalytic activity. More interestingly, a remarkably enhanced ORR activity for the perovskite BaMnO 3 nanorods was observed after coating with a thin layer of carbon, which dominated with a direct four-electron pathway. Meanwhile, the OER process has also been enhanced extraordinarily with the carbon-coating, reaching a maximum of 14.8 mA cm −2 at 1.0 V (vs. Ag/AgCl), which is far superior to both the bare BaMnO 3 nanorods and commercial Pt/C (20 wt%) catalysts. Furthermore, the stabilities of bare BaMnO 3 nanorods for both ORR and OER have also been improved

  16. Magnetic phase transition in MnFeP0.5As0.4Si0.1

    International Nuclear Information System (INIS)

    Wang, J L; Campbell, S J; Tegus, O; Brueck, E; Dou, S X

    2010-01-01

    We have carried out a detailed investigation of the magnetic phase transition in MnFeP 0.5 As 0.4 Si 0.1 . Temperature hysteresis has been observed in the variable temperature magnetization curves (B appl = 0.01 T) with T C W ∼ 302 K on warming and T C C ∼ 292 K on cooling. The first order nature of this transition in MnFeP 0.5 As 0.4 Si 0.1 is confirmed by the negative slope obtained from isotherms of M 2 versus B/M around the critical temperature. Linear thermal expansion measurements reveal a large volume change, ΔV/V∼8.7x10 -3 at the magnetic phase transition and that this magnetovolume effect is suppressed to ΔV/V ∼ 5.5x10 -3 in an applied field of B appl = 1.0 T. Analyses of 57 Fe Moessbauer spectra (4.5 - 300 K) using a random distribution model and taking nearest-neighbour environments into account, indicate that the paramagnetic and ferromagnetic phases coexist over a temperature range of ∼ 45 K around the Curie temperature. The Debye temperature for MnFeP 0.5 As 0.4 Si 0.1 has been evaluated as θ D = 350 ± 20 K from the temperature dependence of the average isomer shift.

  17. Discovery of ferromagnetism with large magnetic anisotropy in ZrMnP and HfMnP

    Energy Technology Data Exchange (ETDEWEB)

    Lamichhane, Tej N.; Taufour, Valentin; Kaluarachchi, Udhara S.; Bud' ko, Sergey L.; Canfield, Paul C. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); The Ames Laboratory, US Department of Energy, Iowa State University, Ames, Iowa 50011 (United States); Masters, Morgan W. [Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States); Parker, David S. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Thimmaiah, Srinivasa [The Ames Laboratory, US Department of Energy, Iowa State University, Ames, Iowa 50011 (United States)

    2016-08-29

    ZrMnP and HfMnP single crystals are grown by a self-flux growth technique, and structural as well as temperature dependent magnetic and transport properties are studied. Both compounds have an orthorhombic crystal structure. ZrMnP and HfMnP are ferromagnetic with Curie temperatures around 370 K and 320 K, respectively. The spontaneous magnetizations of ZrMnP and HfMnP are determined to be 1.9 μ{sub B}/f.u. and 2.1 μ{sub B}/f.u., respectively, at 50 K. The magnetocaloric effect of ZrMnP in terms of entropy change (ΔS) is estimated to be −6.7 kJ m{sup −3} K{sup −1} around 369 K. The easy axis of magnetization is [100] for both compounds, with a small anisotropy relative to the [010] axis. At 50 K, the anisotropy field along the [001] axis is ∼4.6 T for ZrMnP and ∼10 T for HfMnP. Such large magnetic anisotropy is remarkable considering the absence of rare-earth elements in these compounds. The first principle calculation correctly predicts the magnetization and hard axis orientation for both compounds, and predicts the experimental HfMnP anisotropy field within 25%. More importantly, our calculations suggest that the large magnetic anisotropy comes primarily from the Mn atoms, suggesting that similarly large anisotropies may be found in other 3d transition metal compounds.

  18. Discovery of ferromagnetism with large magnetic anisotropy in ZrMnP and HfMnP

    International Nuclear Information System (INIS)

    Lamichhane, Tej N.; Taufour, Valentin; Kaluarachchi, Udhara S.; Bud'ko, Sergey L.; Canfield, Paul C.; Masters, Morgan W.; Parker, David S.; Thimmaiah, Srinivasa

    2016-01-01

    ZrMnP and HfMnP single crystals are grown by a self-flux growth technique, and structural as well as temperature dependent magnetic and transport properties are studied. Both compounds have an orthorhombic crystal structure. ZrMnP and HfMnP are ferromagnetic with Curie temperatures around 370 K and 320 K, respectively. The spontaneous magnetizations of ZrMnP and HfMnP are determined to be 1.9 μ_B/f.u. and 2.1 μ_B/f.u., respectively, at 50 K. The magnetocaloric effect of ZrMnP in terms of entropy change (ΔS) is estimated to be −6.7 kJ m"−"3 K"−"1 around 369 K. The easy axis of magnetization is [100] for both compounds, with a small anisotropy relative to the [010] axis. At 50 K, the anisotropy field along the [001] axis is ∼4.6 T for ZrMnP and ∼10 T for HfMnP. Such large magnetic anisotropy is remarkable considering the absence of rare-earth elements in these compounds. The first principle calculation correctly predicts the magnetization and hard axis orientation for both compounds, and predicts the experimental HfMnP anisotropy field within 25%. More importantly, our calculations suggest that the large magnetic anisotropy comes primarily from the Mn atoms, suggesting that similarly large anisotropies may be found in other 3d transition metal compounds.

  19. Neutron-diffraction studies of the crystal structure and the color enhancement in γ-irradiated tourmaline

    Science.gov (United States)

    Maneewong, Apichate; Seong, Baek Seok; Shin, Eun Joo; Kim, Jeong Seog; Kajornrith, Varavuth

    2016-01-01

    Tourmaline gemstones have an extremely complex composition and show great variety in color. Most color centers are related to transition-metal ions. Oxidation/reduction of these ions is known to be related with the color enhancement of tourmaline caused by gamma-ray ( γ)-irradiation and/or thermal treatment. However, the current understanding of the microscopic structure of the color centers remains weak. In this work, γ-irradiation was performed on three types of tourmaline gemstones to enhance the colors of the gemstones: two pink from Afghanistan and one green from Nigeria. All three samples were irradiated at 600 and 800 kGy. Their crystal structural and chemical behaviors have been investigated by using a Rietveld refinement analysis of neutron diffraction data, Energy Dispersive X-ray Fluorescence (EDXRF), Ultraviolet-visible Spectroscopy (UV-Vis) and X-ray Photoelectron Spectroscopy (XPS), and the results were compared with data obtained for samples in the natural state. Pink tourmaline of a high number of Mn ions (T2, 0.24 wt%) showed significant improvement in the quality of the pink color (rubellite) after irradiation of 800 kGy while the pink tourmaline of low MnO content (T1, 0.08 wt%) showed color adulteration. Pink color enhancement in T2, responding to darker pink, was associated with increases in the two absorption bands, one peaking at 396 and the other at 522 nm, after irradiation. These absorption bands are ascribed to d-d transitions of divalent manganese. T1 with color enhancement due to oxidation of Mn2+ showed a slightly larger distance. The green tourmaline containing much higher amounts of both Mn (T3) and Fe ions, 2.59 wt% and 5.7 wt%, respectively, changed to a yellow color after irradiation at 800 kGy. The refined structural parameters of this sample revealed distortions in the Z site. The distance decreased from 2.033 to 2.0192 Å. In addition, the unit-cell parameter was decreased after irradiation. The color change in T3 is ascribed

  20. Temperature dependence of the ESR linewidth in the paramagnetic phase (T{gt}T{sub C}) of R{sub 1{minus}x}B{sub x}MnO{sub 3+{delta}} (R=La,Pr; B=Ca,Sr)

    Energy Technology Data Exchange (ETDEWEB)

    Rettori, C.; Rao, D.; Singley, J.; Kidwell, D.; Oseroff, S.B. [San Diego State University, San Diego, California 92182 (United States); Causa, M.T. [Centro Atomico Bariloche and Instituto Balseiro 8400, San Carlos de Bariloche (Argentina); Neumeier, J.J.; McClellan, K.J. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Cheong, S. [ATT Bell Laboratories, Murray Hill, New Jersey 07974 (United States); Schultz, S. [University of California, San Diego, California 92037 (United States)

    1997-02-01

    Electron spin resonance (ESR) experiments in the paramagnetic phase of R{sub 1{minus}x}B{sub x}MnO{sub 3+{delta}} (R=La,Pr; B=Ca,Sr) show, for 1.1 T{sub C}{approx_lt}T{approx_lt}2T{sub C}, a linear T increase of the resonance linewidth, {Delta}H, in powders, ceramic pellets, and single crystals. Above {approximately}2T{sub C} a slowdown in the T increase of {Delta}H is observed. The data resemble the results found in other ferromagnetic insulators where the spin-lattice relaxation involves a single-phonon process. We find that the one-phonon process may account for the linear T dependence of the linewidth observed up to {approximately}2T{sub C}. A large T dependence of the resonance intensity above T{sub C} was found in all the samples studied, suggesting the existence of {ital spin clusters} in these compounds over a wide range of temperature. {copyright} {ital 1997} {ital The American Physical Society}

  1. Accounting for the Confound of Meninges in Segmenting Entorhinal and Perirhinal Cortices in T1-Weighted MRI.

    Science.gov (United States)

    Xie, Long; Wisse, Laura E M; Das, Sandhitsu R; Wang, Hongzhi; Wolk, David A; Manjón, Jose V; Yushkevich, Paul A

    2016-10-01

    Quantification of medial temporal lobe (MTL) cortices, including entorhinal cortex (ERC) and perirhinal cortex (PRC), from in vivo MRI is desirable for studying the human memory system as well as in early diagnosis and monitoring of Alzheimer's disease. However, ERC and PRC are commonly over-segmented in T1-weighted (T1w) MRI because of the adjacent meninges that have similar intensity to gray matter in T1 contrast. This introduces errors in the quantification and could potentially confound imaging studies of ERC/PRC. In this paper, we propose to segment MTL cortices along with the adjacent meninges in T1w MRI using an established multi-atlas segmentation framework together with super-resolution technique. Experimental results comparing the proposed pipeline with existing pipelines support the notion that a large portion of meninges is segmented as gray matter by existing algorithms but not by our algorithm. Cross-validation experiments demonstrate promising segmentation accuracy. Further, agreement between the volume and thickness measures from the proposed pipeline and those from the manual segmentations increase dramatically as a result of accounting for the confound of meninges. Evaluated in the context of group discrimination between patients with amnestic mild cognitive impairment and normal controls, the proposed pipeline generates more biologically plausible results and improves the statistical power in discriminating groups in absolute terms comparing to other techniques using T1w MRI. Although the performance of the proposed pipeline is inferior to that using T2-weighted MRI, which is optimized to image MTL sub-structures, the proposed pipeline could still provide important utilities in analyzing many existing large datasets that only have T1w MRI available.

  2. Binding of Mn-deoxyribonucleoside Triphosphates to the Active Site of the DNA Polymerase of Bacteriophage T7

    Energy Technology Data Exchange (ETDEWEB)

    B Akabayov; C Richardson

    2011-12-31

    Divalent metal ions are crucial as cofactors for a variety of intracellular enzymatic activities. Mg{sup 2+}, as an example, mediates binding of deoxyribonucleoside 5'-triphosphates followed by their hydrolysis in the active site of DNA polymerase. It is difficult to study the binding of Mg{sup 2+} to an active site because Mg{sup 2+} is spectroscopically silent and Mg{sup 2+} binds with low affinity to the active site of an enzyme. Therefore, we substituted Mg{sup 2+} with Mn{sup 2+}:Mn{sup 2+} that is not only visible spectroscopically but also provides full activity of the DNA polymerase of bacteriophage T7. In order to demonstrate that the majority of Mn{sup 2+} is bound to the enzyme, we have applied site-directed titration analysis of T7 DNA polymerase using X-ray near edge spectroscopy. Here we show how X-ray near edge spectroscopy can be used to distinguish between signal originating from Mn{sup 2+} that is free in solution and Mn{sup 2+} bound to the active site of T7 DNA polymerase. This method can be applied to other enzymes that use divalent metal ions as a cofactor.

  3. MR signal of the solid portion of pilocytic astrocytoma on T2-weighted images: is it useful for differentiation from medulloblastoma?

    International Nuclear Information System (INIS)

    Arai, Kiyokazu; Yagi, Akiko; Taketomi-Takahashi, Ayako; Morita, Hideo; Koyama, Yoshinori; Endo, Keigo; Sato, Noriko; Aoki, Jun; Oba, Hiroshi; Ishiuchi, Shogo; Saito, Nobuhito

    2006-01-01

    Background and purpose: Although imaging features of cerebellar pilocytic astrocytoma and medulloblastoma have been described in many texts, original comparisons of magnetic resonance intensity between these two tumours are limited. In the present study the results of magnetic resonance imaging (MRI) were reviewed, focusing especially on the signal intensity of the solid portion of these neoplasms. Methods: MR images of ten cerebellar pilocytic astrocytomas and ten medulloblastomas were reviewed. The signal intensities of the solid components were graded on a scale of 1 to 5, with higher scores indicating a signal intensity closer to that of water. The degree of enhancement, tumour cysts and peripheral oedema were evaluated on MR images. When the solid portion was heterogeneous (i.e. mixed signal intensity or degree of enhancement), the dominant area was selected for evaluation. On T2-weighted images, the signal intensity of the solid portion was equal to that of cerebrospinal fluid (CSF) in 50% of pilocytic astrocytomas. No medulloblastomas showed such hyperintensity. Most medulloblastomas (80%) were isointense to grey matter. On T1-weighted images, the signal intensity varied widely in pilocytic astrocytomas; however, all medulloblastomas were iso- or hypointense to grey matter. The MR enhancement pattern, cystic component and peripheral oedema all varied in both tumour types and no specific features were identified. A signal intensity of the solid portion isointense to CSF on T2-weighted images was characteristic of cerebellar pilocytic astrocytomas; this was not observed in medulloblastomas. Attention to T2-weighted imaging of the solid portions of a tumour is easy and helpful in differentiating between cerebellar pilocytic astrocytoma and medulloblastoma. (orig.)

  4. Post-contrast T1-weighted sequences in pediatric abdominal imaging: comparative analysis of three different sequences and imaging approach

    Energy Technology Data Exchange (ETDEWEB)

    Roque, Andreia; Ramalho, Miguel; AlObaidy, Mamdoh; Heredia, Vasco; Burke, Lauren M.; De Campos, Rafael O.P.; Semelka, Richard C. [University of North Carolina at Chapel Hill, Department of Radiology, Chapel Hill, NC (United States)

    2014-10-15

    Post-contrast T1-weighted imaging is an essential component of a comprehensive pediatric abdominopelvic MR examination. However, consistent good image quality is challenging, as respiratory motion in sedated children can substantially degrade the image quality. To compare the image quality of three different post-contrast T1-weighted imaging techniques - standard three-dimensional gradient-echo (3-D-GRE), magnetization-prepared gradient-recall echo (MP-GRE) and 3-D-GRE with radial data sampling (radial 3-D-GRE) - acquired in pediatric patients younger than 5 years of age. Sixty consecutive exams performed in 51 patients (23 females, 28 males; mean age 2.5 ± 1.4 years) constituted the final study population. Thirty-nine scans were performed at 3 T and 21 scans were performed at 1.5 T. Two different reviewers independently and blindly qualitatively evaluated all sequences to determine image quality and extent of artifacts. MP-GRE and radial 3-D-GRE sequences had the least respiratory motion (P < 0.0001). Standard 3-D-GRE sequences displayed the lowest average score ratings in hepatic and pancreatic edge definition, hepatic vessel clarity and overall image quality. Radial 3-D-GRE sequences showed the highest scores ratings in overall image quality. Our preliminary results support the preference of fat-suppressed radial 3-D-GRE as the best post-contrast T1-weighted imaging approach for patients under the age of 5 years, when dynamic imaging is not essential. (orig.)

  5. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Fellner, Franz A. [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria) and Zentrales Radiologie Institut, Allgemeines Krankenhaus der Stadt Linz, Krankenhausstr. 9, 4020 Linz (Austria)]. E-mail: franz.fellner@akh.linz.at; Fellner, Claudia [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria); Aichner, Franz T. [Abteilung fuer Neurologie, Landes-Nervenklinik Wagner-Jauregg, Linz (Austria); Moelzer, Guenther [Institut fuer Radiologie, Landes-Nervenklinik Wagner Jauregg, Linz (Austria)

    2005-11-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 {mu}s, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis.

  6. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis

    International Nuclear Information System (INIS)

    Fellner, Franz A.; Fellner, Claudia; Aichner, Franz T.; Moelzer, Guenther

    2005-01-01

    We examined six patients with isolated venous thrombosis (n = 2), or venous thrombosis combined with sinus thrombosis (n = 4) (CVT). The clinical symptoms were non-specific (acute cephalea, paresis, epileptic seizure, progressive speech disorder). All examinations were performed on a 1.5 T system (Magnetom Symphony, Siemens, Erlangen, Germany), maximum gradient field strength 30 mT/m, minimal gradient rise time 450 μs, according to the following protocol: Transverse T2-weighted turbo spin-echo (TSE), fluid attenuated inversion recovery (FLAIR), T1-weighted spin-echo (SE), before and after administration of contrast medium, T2*-weighted conventional gradient-echo (GRE), T2*-weighted spin-echo echo planar imaging (SE EPI), both without and with diffusion weighting as well as two-dimensional (2D) venous time-of-flight (TOF) MRA. The venous thromboses were best detectable in the T2*-weighted conventional GRE sequence in all patients. In two patients, the CVT was discernible only in this sequence. The sinus thrombosis was well discernible only in the T2*-weighted GRE sequence in only one case; in the remaining cases it was detectable only with difficulty. For these cases, other sequences such as SE, diffusion-weighted, or 2D-TOF-MRA sequence were superior. The T2*-weighted conventional GRE sequence was superior to the T2*-weighted SE EPI sequence in all patients. To sum up, it can be concluded, that T2*-weighted conventional GRE sequences are possibly the best method of detection of acute cortical vein thromboses. Therefore, it seems to be of benefit to integrate a T2*-weighted conventional GRE sequence into the MR-protocol for the diagnosis of isolated cortical vein thrombosis

  7. (PO_4)"3"− polyanions doped LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2: An ultrafast-rate, long-life and high-voltage cathode material for Li-ion rechargeable batteries

    International Nuclear Information System (INIS)

    Cong, Lina; Zhao, Qin; Wang, Zhao; Zhang, Yuhang; Wu, Xinglong; Zhang, Jingping; Wang, Rongshun; Xie, Haiming; Sun, Liqun

    2016-01-01

    Highlights: • LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 layered structure is doped with (PO_4)"3"− polyanions. • Results confirm that (PO_4)"3"− influences MO_6 octahedral environment in LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 lattice. • Charge–discharge properties are investigated under high voltage battery operation. • Cycling and rate performance of the doped materials is markedly enhanced. • Pre-cycling treatment inhibits microcracks at the grain boundaries at 4.7–2.8 V. - Abstract: Layered compounds LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 have recently received much attention as they have been regarded as a promising cathode materials for industrial application. However, its fast energy density decay and poor rate performance which originate from structure disruption especially at high rate and high cut-off voltage limit its large-scale application. Here, a novel designed concept and facile method were firstly used to fabricate (PO_4)"3"− polyanions doped layered LiNi_1_/_3Co_1_/_3Mn_1_/_3O_2 (LNMC-(PO_4) _0_._0_1_5-O_1_._9_4) structure, which could offer more stable high-voltage cycling performance and high rate capability. We attribute this improved performance to the robust P_t_e_t-O covalence, which will stabilize the oxygen close-packed structure during repeated cycling. Moreover, our stepwise pre-cycling treatments could effectively restrain the formation of micro-cracks and non-crystallization defects, and significantly improve cyclic durability with high charge voltage of 4.7V. The LNMC-(PO_4) _0_._0_1_5-O_1_._9_4 electrode can still delivers capacity retention of 81% after 200 cycles at a current density of 300mA g"−"1. The preliminary results reported here manifest that this novel-designed LNMC-(PO_4) _0_._0_1_5-O_1_._9_4 material represents an attractive alternative to ultrafast-rate, long-life and high-voltage electrode material for lithium ion batteries.

  8. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  9. Characterization of D-maltose as a T2 -exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-09-01

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med 80:1158-1164, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  10. Preparation of Mn doped CeO{sub 2} nanoparticles with enhanced ferromagnetism

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@mepcoeng.ac.in; Winfred Shashikanth, F.

    2017-06-15

    Spherical-like CeO{sub 2} and Mn-doped CeO{sub 2} using 6-aminohexanoic acid as surfactant exhibit enhanced ferromagnetism. The optical absorption spectra reveal a red shift with a band gap of 2.51 eV. The mechanics of ferromagnetism and the red shift were analyzed. These results provide a promising platform for developing a dilute magnetic semiconductor in spintronics. - Highlights: • Pure and Mn-doped CeO{sub 2} is prepared with aminohexanoic acid as capping. • They exhibit wide optical absorption with red-shift in their band gap. • Mn-doped CeO{sub 2} nanoparticle exhibit hysteresis at room temperature. • Results were promising to use in spintronics and opto-electronics field.

  11. The value of 3D T1-weighted gradient-echo MR imaging for evaluation of the appendix during pregnancy: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Kim, Seong Hyun; Choi, Dongil; Lee, Soon Jin; Rhim, Hyunchul; Park, Min Jung (Depts. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)), email: kshyun@skku.edu

    2011-10-15

    Background The use of oral contrast has been essential for the identification of a normal appendix on MR imaging during pregnancy. However, stool could be used as a positive oral contrast as it is characterized by a relatively high signal on T1-weighted imaging, and 3D T1-weighted gradient-echo (T1W-GRE) MR imaging has been used to evaluate 3 mm diameter intestines in fetuses. Purpose To evaluate the added value of 3D T1W-GRE MR imaging in combination with T2-weighted imaging (T2WI) compared to T2WI alone for evaluating the appendix during pregnancy. Material and Methods Eighteen consecutive pregnant patients who were clinically suspected of having acute appendicitis underwent appendix MR imaging which included T2WI with or without spectral presaturation attenuated inversion-recovery (SPAIR) fat suppression, and 3D T1W-GRE with SPAIR fat suppression. Two radiologists reviewed the two image sets (the T2WI set and the combined set of T2WI and 3D T1W-GRE images). Pathologic and clinical results served as the reference standard. The differences in the degree of visibility of the appendix and confidence scale for diagnosing acute appendicitis between two image sets were compared by using the paired Wilcoxon signed rank test. Results For both reviewers, the degree of visibility of the appendix using the combined T2WI and 3D T1W-GRE images was significantly higher than using T2WI alone (P < 0.01), and the confidence levels for acute appendicitis using combined T2WI and 3D T1W-GRE images were significantly different from those using T2WI alone (P < 0.01). In the 13 patients with a normal appendix, both reviewers showed improved confidence levels for appendicitis using combined T2WI and 3D T1W-GRE images than T2WI alone. Conclusion Adding 3D T1W-GRE images to T2WI is helpful for identification of the appendix, as compared to T2WI alone in pregnant women without ingestion of oral contrast material. This may improve diagnostic confidence for acute appendicitis in pregnant

  12. Characterization of Mn-resistant endophytic bacteria from Mn-hyperaccumulator Phytolacca americana and their impact on Mn accumulation of hybrid penisetum.

    Science.gov (United States)

    Zhang, Wen-Hui; Chen, Wei; He, Lin-Yan; Wang, Qi; Sheng, Xia-Fang

    2015-10-01

    Three hundred Mn-resistant endophytic bacteria were isolated from the Mn-hyperaccumulator, Phytolacca americana, grown at different levels of Mn (0, 1, and 10mM) stress. Under no Mn stress, 90%, 92%, and 11% of the bacteria produced indole acetic acid (IAA), siderophore, and 1-aminocyclopropane-1-carboxylate (ACC) deaminase, respectively. Under Mn stress, 68-94%, 91-92%, and 21-81% of the bacteria produced IAA, siderophore, and ACC deaminase, respectively. Greater percentages of ACC deaminase-producing bacteria were found in the Mn-treated P. americana. Furthermore, the ratios of IAA- and siderophore-producing bacteria were significantly higher in the Mn treated plant leaves, while the ratio of ACC deaminase-producing bacteria was significantly higher in the Mn treated-roots. Based on 16S rRNA gene sequence analysis, Mn-resistant bacteria were affiliated with 10 genera. In experiments involving hybrid penisetum grown in soils treated with 0 and 1000mgkg(-1) of Mn, inoculation with strain 1Y31 was found to increase the root (ranging from 6.4% to 18.3%) and above-ground tissue (ranging from 19.3% to 70.2%) mass and total Mn uptake of above-ground tissues (64%) compared to the control. Furthermore, inoculation with strain 1Y31 was found to increase the ratio of IAA-producing bacteria in the rhizosphere and bulk soils of hybrid penisetum grown in Mn-added soils. The results showed the effect of Mn stress on the ratio of the plant growth-promoting factor-producing endophytic bacteria of P. americana and highlighted the potential of endophytic bacterium as an inoculum for enhanced phytoremediation of Mn-polluted soils by hybrid penisetum plants. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound

    International Nuclear Information System (INIS)

    Wintermark, Max; Sumer, Suna; Lau, Benison; Cupino, Alan; Tustison, Nicholas J; Demartini, Nicholas; Elias, William J; Kassell, Neal; Patrie, James T; Xin, Wenjun; Eames, Matt; Snell, John; Hananel, Arik; Aubry, Jean-Francois

    2014-01-01

    Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called ‘virtual CT’ to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland–Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (−0.22–0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the

  14. Contrast-enhanced 3T MR Perfusion of Musculoskeletal Tumours: T1 Value Heterogeneity Assessment and Evaluation of the Influence of T1 Estimation Methods on Quantitative Parameters.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain

    2017-12-01

    To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.

  15. Effect of soil type and application method on nutrients absorption and utilization by grape plants 1-Absorption and utilization of manganese using Mn-54

    International Nuclear Information System (INIS)

    Mohamed, F.A.; Sharaf, A.N.M.; Khamis, M.A.; Sharaf, M.M.

    2000-01-01

    This work was conducted to study effect of soil type and application method on absorption, translocation and utilization of Mn by grape plants. One year old rooted cuttings of grape (Cv. Ruby seedless) were transplanted in plastic containers filled with 15 kg of three different soils, i.e. clay loam soil, sandy soil and calcareous soil. Fertilization treatments were as follows: Tap water (control) (T1); soil application of N, P,K and Mg (T2); T2 plus soil application of Fe, Mn and Zn (T4). Also, pot experiment was carried out using Mn SO4 at 5ppm for soil application and at 0.5% for foliar application and Mn-54 was used for labelling both solutions. Manganese contents in different organs of grape plant were significantly increased by the three fertilization treatments as compared to those of control. Moreover, highest Mn level was obtained due to foliar application of micro elements and soil application of macro elements T 4 . followed by soil application of both macro-and micro elements T 3 , soil application of macro elements only T2 and control T1

  16. Magnetic properties of PrMn2-xFexGe2-57Fe Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Wang, J L; Campbell, S J; Cadogan, J M; Tegus, O; Studer, A J; Hofmann, M

    2006-01-01

    We have investigated the magnetic behaviour of PrMn 2-x Fe x Ge 2 compounds with x = 0.4, 0.6 and 0.8 over the temperature range 4.2-350 K using ac magnetic susceptibility, dc magnetization and 57 Fe Moessbauer effect spectroscopy, as well as neutron diffraction for the PrMn 1.2 Fe 0.8 Ge 2 compound. Replacement of Mn with Fe leads to contraction of the unit cell and a shortening of the Mn-Mn spacing, resulting in modification of the magnetic structure. PrMn 1.6 Fe 0.4 Ge 2 is an intralayer antiferromagnet at room temperature and ferromagnetic below T C inter ∼230 K with additional ferromagnetic ordering of the Pr sublattice detected below T C Pr ∼30 K. Re-entrant ferromagnetism has been observed in PrMn 1.4 Fe 0.6 Ge 2 with four magnetic transitions (T N intra ∼333 K, T C inter ∼168 K, T N inter ∼152 K and T C Pr ∼40 K). Moreover, it was found that T C inter and T C Pr increase with applied field while T N inter decreases. PrMn 1.2 Fe 0.8 Ge 2 is antiferromagnetic with T N intra ∼242 K and T N inter ∼154 K. The magnetic transition temperatures for all compounds are also marked by changes in the 57 Fe magnetic hyperfine field and the electric quadrupole interaction parameters. The 57 Fe transferred hyperfine field at 4.5 K in PrMn 1.6 Fe 0.4 Ge 2 and PrMn 1.4 Fe 0.6 Ge 2 is reduced (below the ordering temperature of the Pr sublattice) compared with that at 80 K (above T C Pr ), indicating that the transferred hyperfine field from Pr acts in the opposite direction to that from the Mn atoms. The neutron data for PrMn 1.2 Fe 0.8 Ge 2 demonstrate that an anisotropic thermal expansion occurs within the interplanar antiferromagnetic range

  17. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun [College of Medicine, Inje University, Seoul (Korea, Republic of)

    2000-02-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  18. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    International Nuclear Information System (INIS)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun

    2000-01-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  19. Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Ronot, Maxime; Vilgrain, Valerie; Beers, Bernard E. van [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique- Hopitaux de Paris, Laboratory of Physiological and Molecular Imaging of the Abdomen (IPMA) and Department of Radiology, Clichy Cedex (France); Maggiori, Leon; Panis, Yves [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Colorectal Surgery, Clichy (France); Paradis, Valerie [University Paris Diderot, Sorbonne Paris Cite, INSERM UMR 773, University Hospitals Paris Nord Val de Seine, Beaujon, Assistance Publique-Hopitaux de Paris, Department of Pathology, Clichy (France)

    2013-08-15

    To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm{sup 2}) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P {<=} 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. (orig.)

  20. A PP2C-1 Allele Underlying a Quantitative Trait Locus Enhances Soybean 100-Seed Weight

    Institute of Scientific and Technical Information of China (English)

    Xiang Lu; Yong-Cai Lai; Wei-Guang Du; Wei-Qun Man; Shou-Yi Chen; Jin-Song Zhang; Qing Xiong; Tong Cheng; Qing-Tian Li; Xin-Lei Liu; Ying-Dong Bi; Wei Li; Wan-Ke Zhang; Biao Ma

    2017-01-01

    Cultivated soybeans may lose some useful genetic loci during domestication.Introgression of genes from wild soybeans could broaden the genetic background and improve soybean agronomic traits.In this study,through whole-genome sequencing of a recombinant inbred line population derived from a cross between a wild soybean ZYD7 and a cultivated soybean HN44,and mapping of quantitative trait loci for seed weight,we discovered that a phosphatase 2C-1 (PP2C-1) allele from wild soybean ZYD7 contributes to the increase in seed weight/size.PP2C-1 may achieve this function by enhancing cell size of integument and activating a subset of seed trait-related genes.We found that PP2C-1 is associated with GmBZR1,a soybean ortholog of Arabidopsis BZR1,one of key transcription factors in brassinosteroid (BR) signaling,and facilitate accumulation of dephosphorylated GmBZR1.In contrast,the PP2C-2 allele with variations of a few amino acids at the N-terminus did not exhibit this function.Moreover,we showed that GmBZR1 could promote seed weight/size in transgenic plants.Through analysis of cultivated soybean accessions,we found that 40% of the examined accessions do not have the PP2C-1 allele,suggesting that these accessions can be improved by introduction of this allele.Taken together,our study identifies an elite allele PP2C-1,which can enhance seed weight and/or size in soybean,and pinpoints that manipulation of this allele by molecular-assisted breeding may increase production in soybean and other legumes/crops.

  1. Temperature dependence of the ESR linewidth in the paramagnetic phase (T>TC) of R1-xBxMnO3+δ (R=La,Pr; B=Ca,Sr)

    International Nuclear Information System (INIS)

    Rettori, C.; Rao, D.; Singley, J.; Kidwell, D.; Oseroff, S.B.; Causa, M.T.; Neumeier, J.J.; McClellan, K.J.; Cheong, S.; Schultz, S.

    1997-01-01

    Electron spin resonance (ESR) experiments in the paramagnetic phase of R 1-x B x MnO 3+δ (R=La,Pr; B=Ca,Sr) show, for 1.1 T C approx-lt T approx-lt 2T C , a linear T increase of the resonance linewidth, ΔH, in powders, ceramic pellets, and single crystals. Above ∼2T C a slowdown in the T increase of ΔH is observed. The data resemble the results found in other ferromagnetic insulators where the spin-lattice relaxation involves a single-phonon process. We find that the one-phonon process may account for the linear T dependence of the linewidth observed up to ∼2T C . A large T dependence of the resonance intensity above T C was found in all the samples studied, suggesting the existence of spin clusters in these compounds over a wide range of temperature. copyright 1997 The American Physical Society

  2. Magnetocaloric properties in La{sub 1−x}Ca{sub x}MnO{sub 3} thin films: Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Restrepo-Parra, E., E-mail: erestrepopa@unal.edu.co; Ramos-Rivera, L.; Londoño-Navarro, J.

    2014-02-15

    The magnetocaloric effect (MCE) of La{sub 1−x}Ca{sub x}MnO{sub 3} was analyzed when varying the stoichiometry (x=0.2, 0.33, 0.4 and 0.5) and the external applied magnetic field. Simulations were carried out using the Monte Carlo method having a configuration ascribed by the set S{sub z} of all-site spin projections, under the Metropolis algorithm. La{sub 1−x}Ca{sub x}MnO{sub 3} is characterized for three types of magnetic ions corresponding to Mn{sup 4+} (S=3/2), which are bonded to Ca{sup 2+}, and Mn{sup 3+}(e{sub g}) and Mn{sup 3+}(e{sub g′}, S=2), which are both bonded to La{sup 3+}. Different interactions must be considered depending on the type of interacting ions. The entropy change ΔS in an isothermal process as well as the temperature change ΔT in an adiabatic process was determined with this model. Both ΔS and ΔT show stoichiometry-dependent maximums near the paramagnetic–ferromagnetic transition temperature (T{sub C}), confirming the order–disorder change at this temperature. The strong dependence in La{sub 1−x}Ca{sub x}MnO{sub 3} of the MCE on the stoichiometry and the external magnetic field makes this phenomenon important for different technological applications, particularly in refrigeration. - Highlights: • Thermal behavior of entropy, susceptibility and isothermal entropy change is studied. • ΔS and ΔT present a transition at the critical temperature depending on the stoichiometry. • Semi-classical Heisenberg Hamiltonian allows simulation of magnetocaloric effect in LCMO. • External magnetic field produces changes in ΔS and ΔT observed in the shifting of T{sub C}.

  3. Magnetization transfer imaging identifies basal ganglia abnormalities in adult ADHD that are invisible to conventional T1 weighted voxel-based morphometry

    Directory of Open Access Journals (Sweden)

    Arjun Sethi

    2017-01-01

    Full Text Available In childhood, Attention Deficit Hyperactivity Disorder (ADHD is reliably associated with reduced volume of the striatum. In contrast, striatal abnormalities are infrequently detected in voxel-based morphometry (VBM neuroimaging studies of adults with ADHD. This discrepancy has been suggested to reflect normalisation of striatal morphology with age and prolonged treatment of symptoms. If so, this would indicate that while striatal abnormalities are linked to symptom expression in childhood, they cannot explain the persistence of these symptoms in adulthood. However, this may not be case. Instead, we hypothesized that the lack of evidence for striatal abnormalities in adult ADHD may reflect poor sensitivity of typical (T1-weighted neuroimaging to detect subcortical differences. To address this, we acquired both magnetisation transfer (MT saturation maps optimised for subcortical contrast, and conventional T1-weighted images in 30 adults with ADHD and 30 age, IQ, gender and handedness-matched controls. Using VBM of both datasets, we demonstrate volumetric reductions within the left ventral striatum on MT that are not observed on identically pre-processed T1-weighted images from the same participants. Nevertheless, both techniques reported similar sensitivity to cortical abnormalities in the right inferior parietal lobe. Additionally, we show that differences in striatal iron may potentially explain this reduced sensitivity of T1-weighted images in adults. Together, these findings indicate that prior VBM studies reporting no abnormalities in striatal volume in adult ADHD might have been compromised by the methodological insensitivity of T1-weighted VBM to subcortical differences, and that structural abnormalities of the striatum in ADHD do indeed persist into adulthood.

  4. SU-D-303-03: Impact of Uncertainty in T1 Measurements On Quantification of Dynamic Contrast Enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, M; Cao, Y [The University of Michigan, Ann Arbor, MI (United States)

    2015-06-15

    Purpose: Quantification of dynamic contrast enhanced (DCE) MRI requires native longitudinal relaxation time (T1) measurement. This study aimed to assess uncertainty in T1 measurements using two different methods. Methods and Materials: Brain MRI scans were performed on a 3T scanner in 9 patients who had low grade/benign tumors and partial brain radiotherapy without chemotherapy at pre-RT, week-3 during RT (wk-3), end-RT, and 1, 6 and 18 months after RT. T1-weighted images were acquired using gradient echo sequences with 1) 2 different flip angles (50 and 150), and 2) 5 variable TRs (100–2000ms). After creating quantitative T1 maps, average T1 was calculated in regions of interest (ROI), which were distant from tumors and received a total of accumulated radiation doses < 5 Gy at wk-3. ROIs included left and right normal Putamen and Thalamus (gray matter: GM), and frontal and parietal white matter (WM). Since there were no significant or even a trend of T1 changes from pre-RT to wk-3 in these ROIs, a relative repeatability coefficient (RC) of T1 as a measure of uncertainty was estimated in each ROI using the data pre-RT and at wk-3. The individual T1 changes at later time points were evaluated compared to the estimated RCs. Results: The 2-flip angle method produced small RCs in GM (9.7–11.7%) but large RCs in WM (12.2–13.6%) compared to the saturation-recovery (SR) method (11.0–17.7% for GM and 7.5–11.2% for WM). More than 81% of individual T1 changes were within T1 uncertainty ranges defined by RCs. Conclusion: Our study suggests that the impact of T1 uncertainty on physiological parameters derived from DCE MRI is not negligible. A short scan with 2 flip angles is able to achieve repeatability of T1 estimates similar to a long scan with 5 different TRs, and is desirable to be integrated in the DCE protocol. Present study was supported by National Institute of Health (NIH) under grant numbers; UO1 CA183848 and RO1 NS064973.

  5. Magnetic Properties and Magnetocaloric Effect in Layered NdMn1.9Ti0.1Si2

    Directory of Open Access Journals (Sweden)

    M.F. Md Din

    2014-04-01

    Full Text Available The structural and magnetic properties of the NdMn1.9Ti0.1Si2 compund have been studied by high-intensity x-ray and high-resolution neutron powder diffraction, specific heat, dc magnetization, and differential scanning calorimetry measurements over the temperature range of 3-450 K. The Curie temperature and Néel temperature of layered NdMn1.9Ti0.1Si2 are indicated as TC ~ 22 K and TN ~ 374 K respectively. The first order magnetic transition from antiferromagnetic [AFil-type] to ferromagnetic [F(Nd+Fmc] around TC is found in layered NdMn1.9Ti0.1Si2 and is associated with large magnetocaloric effect. This behavior has been confirmed as a contribution of the magnetostructural coupling by using neutron and x-ray powder diffraction. The magnetic entropy change –ΔSM ~ 15.3 J kg-1 K-1 and adiabatic temperature change ΔTad ~ 4.7 K have been determined using magnetization and specific heat measurement under 0-5 T applied fields. This compound exhibits almost no thermal and magnetic hysteresis, thus potentially applicable in low temperature region for magnetic refrigerator material

  6. Layered oxides-LiNi1/3Co1/3Mn1/3O2 as anode electrode for symmetric rechargeable lithium-ion batteries

    Science.gov (United States)

    Wang, Yuesheng; Feng, Zimin; Yang, Shi-Ze; Gagnon, Catherine; Gariépy, Vincent; Laul, Dharminder; Zhu, Wen; Veillette, René; Trudeau, Michel L.; Guerfi, Abdelbast; Zaghib, Karim

    2018-02-01

    High-performance and long-cycling rechargeable lithium-ion batteries have been in steadily increasing demand for the past decades. Nevertheless, the two dominant anodes at the moment, graphite and L4T5O12, suffer from a safety issue of lithium plating (operating voltage at ∼ 0.1 V vs. Li+/Li) and low capacity (175 mAh/g), respectively. Here, we report LiNi1/3Co1/3Mn1/3O2 as an alternative anode material which has a working voltage of ∼1.1 V and a capacity as high as 330 mAh/g at the current rate of C/15. Symmetric cells with both electrodes containing LiNi1/3Co1/3Mn1/3O2 can deliver average discharge voltage of 2.2 V. In-situ XRD, HRTEM and first principles calculations indicate that the reaction mechanism of a LiNi1/3Co1/3Mn1/3O2 anode is comprised mainly of conversion. Both the fundamental understanding and practical demonstrations suggest that LiNi1/3Co1/3Mn1/3O2 is a promising negative electrode material for lithium-ion batteries.

  7. FeOOH-loaded MnO2 nano-composite: An efficient emergency material for thallium pollution incident.

    Science.gov (United States)

    Chen, Meiqing; Wu, Pingxiao; Yu, Langfeng; Liu, Shuai; Ruan, Bo; Hu, Haihui; Zhu, Nengwu; Lin, Zhang

    2017-05-01

    A FeOOH-loaded MnO 2 nano-composite was developed as an emergency material for Tl(I) pollution incident. Structural characterizations showed that FeOOH successfully loaded onto MnO 2 , the nanosheet-flower structure and high surface area (191 m 2  g -1 ) of material contributed to the excellent performance for Tl(I) removal. FeOOH-loaded MnO 2 with a Fe/Mn molar ratio of 1:2 exhibited a noticeable enhanced capacity for Tl(I) removal compared to that of pure MnO 2 . The outstanding performance for Tl(I) removal involves in extremely high efficiency (achieved equilibrium and drinking water standard within 4 min) and the large maximum adsorption capacity (450 mg g -1 ). Both the control-experiment and XPS characterization proved that the removal mechanism of Tl(I) on FeOOH-loaded MnO 2 included adsorption and oxidation: the oxidation of MnO 2 played an important role for Tl(I) removal, and the adsorption of FeOOH loaded on MnO 2 enhanced Tl(I) purification at the same time. In-depth purification of Tl(I) had reach drinking water standards (0.1 μg L -1 ) at pH above 7, and there wasn't security risk produced from the dissolution of Mn 2+ and Fe 2+ . Moreover, the as-prepared material could be utilized as a recyclable adsorbent regenerated by using NaOH-NaClO binary solution. Therefore, the synthesized FeOOH-loaded MnO 2 in this study has the potential to be applied as an emergency material for thallium pollution incident. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Highly stabilized and photoluminescence enhancement of ZnS:Mn2+ nanoparticles in biotin matrix

    International Nuclear Information System (INIS)

    Keshari, Ashish K.; Pandey, Avinash C.

    2009-01-01

    We synthesized the ZnS:Mn 2+ nanoparticles passivated by biocompatible layer, namely, biotin by chemical precipitation route and studied their temporal evolution for size, structure, optical, and photoluminescence stability. To monitor the structural and optoelectronic properties of the nanoparticles with time, we have characterized the grown product by x-ray diffraction, small angle x-ray scattering, UV visible, and photoluminescence spectroscopic techniques at a regular interval for a period of three months. Results showed that the properties of nanophosphors capped with biotin are remaining the same even after 3 months. Energy dispersive x-ray analysis of 3 month aged sample shows long time compatibility between ZnS:Mn 2+ nanoparticles and the biotin. This is also confirmed by electron microscopy that the growth of the nanoparticles is strongly arrested by the biotin. X-ray photoelectron spectra were also recorded to show the chemical state of the elements. Enhanced ratio of Zn 2p to Mn 2p peaks in the x-ray photoelectron spectra of ZnS:Mn 2+ nanoparticles shows that the Mn 2+ ions are incorporated within ZnS host matrix. We found that biotin capping will enhance the luminescence from ZnS:Mn 2+ nanoparticles as compared to without capped particles. Absence of biotin will gradually degrade the luminescence upon aging while drastic degradation in luminescence intensity was observed after annealing. Properties show that biotin also protected the nanoparticles from any environmental attack

  9. Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia?

    International Nuclear Information System (INIS)

    Baudelet, Christine; Ansiaux, Reginald; Jordan, Benedicte F; Havaux, Xavier; Macq, Benoit; Gallez, Bernard

    2004-01-01

    T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions

  10. Precipitation of T1 and θ′ Phase in Al-4Cu-1Li-0.25Mn During Age Hardening: Microstructural Investigation and Phase-Field Simulation

    Science.gov (United States)

    Häusler, Ines; Schwarze, Christian; Bilal, Muhammad Umer; Valencia Ramirez, Daniela; Hetaba, Walid; Darvishi Kamachali, Reza; Skrotzki, Birgit

    2017-01-01

    Experimental and phase field studies of age hardening response of a high purity Al-4Cu-1Li-0.25Mn-alloy (mass %) during isothermal aging are conducted. In the experiments, two hardening phases are identified: the tetragonal θ′ (Al2Cu) phase and the hexagonal T1 (Al2CuLi) phase. Both are plate shaped and of nm size. They are analyzed with respect to the development of their size, number density and volume fraction during aging by applying different analysis techniques in TEM in combination with quantitative microstructural analysis. 3D phase-field simulations of formation and growth of θ′ phase are performed in which the full interfacial, chemical and elastic energy contributions are taken into account. 2D simulations of T1 phase are also investigated using multi-component diffusion without elasticity. This is a first step toward a complex phase-field study of T1 phase in the ternary alloy. The comparison between experimental and simulated data shows similar trends. The still unsaturated volume fraction indicates that the precipitates are in the growth stage and that the coarsening/ripening stage has not yet been reached. PMID:28772481

  11. Tolerance factor rules for Sr1-x-yCaxBayMnO3 perovskites

    International Nuclear Information System (INIS)

    Dabrowski, B.; Chmaissem, O.; Mais, J.; Kolesnik, S.; Jorgensen, J.D.; Short, S.

    2003-01-01

    Synthesis of new perovskite Sr 1-x-y Ca x Ba y MnO 3-δ compounds is described in detail and dependence of their phase stability and structural distortions on the tolerance factor is discussed. Oxygen contents have been measured over extended temperature and composition ranges. Neutron powder diffraction was used to precisely measure the A-O and Mn-O bond lengths and derive accurate interatomic distances [Ca-O], [Sr-O], [Ba-O], and [Mn-O]. By using these parameters instead of tabulated ionic radii we have derived the functional dependence of the tolerance factor t=t(x,y,T,δ) on composition, temperature, and oxygen content. At a fixed oxygen content, the tolerance factor is an increasing function of temperature as a result of greater thermal expansion of the average bond relative to the bond. We find that the stability of the perovskite phase at high temperature is governed, as expected, by the magnitude of tolerance factor (t≤1) which can be adjusted by controlling the oxygen content 3-δ. This dependence of the tolerance factor on oxygen content and temperature can be utilized to design synthesis conditions for the controlled formation of the new, kinetically stable, perovskite phases

  12. Kinetic Investigations of SiMn Slags From Different Mn Sources

    Science.gov (United States)

    Kim, Pyunghwa Peace; Tangstad, Merete

    2018-03-01

    The kinetics of MnO and SiO2 reduction were investigated for Silicomanganese (SiMn) slags using a Thermogravimetric analysis (TGA) between 1773 K and 1923 K (1500 °C and 1650 °C) under CO atmospheric pressure. The charge materials were based on Assmang ore and HC FeMn Slag. Rate models for MnO and SiO2 reduction were applied to describe the metal-producing rates, as shown by the following equations: r_{MnO} = k_{MnO} × A × ( {a_{MnO} - {a_{Mn} }/{K_{T }}} ) r_{{{SiO}2 }} = k_{SiO2} × A × ( {a_{{{SiO}2 }} - {a_{Si} }/{K_{T }}} ). The results show that the choice of raw materials in the charge considerably affected the reduction rate of MnO and SiO2. The highest reduction rate was found to be from charges using HC FeMn slag. The difference in the driving forces was insignificant among the SiMn slags, and the similar slag viscosities could not explain the different reduction rates. Instead, the difference is attributed to small amounts of sulfur and the amount of iron in the charge. In addition, the rate models were applicable to describe the reduction of MnO and SiO2 in SiMn slags.

  13. MR urography (MRU) of non-dilated ureter with diuretic administration: Static fluid 2D FSE T2-weighted versus 3D gadolinium T1-weighted GE excretory MR

    International Nuclear Information System (INIS)

    Roy, C.; Ohana, M.; Host, Ph.; Alemann, G.; Labani, A.; Wattiez, A.; Lang, H.

    2014-01-01

    T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter.•T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis).•T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium.•CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction.•CE-MRU is less convenient for patients. T2w-MRU with multiple orientations and diuretic is sufficient to identify non-dilated ureter. T2w-MRU offers information on ureteral contractions and could be proposed to detect initial obstruction before hydronephrosis occurs (for instance in cases of endometriosis). T2w-MRU could also be used to evaluate potential renal donors or in patients unable to receive gadolinium. CE-MRU rapidly produces an overdistended bladder with a risk of false positive diagnosis of mild obstruction. CE-MRU is less convenient for patients. The goal of this prospective study was to compare the efficiency of two types of MRU after diuretic administration to identify the non-dilated ureter. MR pelvic examinations were performed in 126 patients after receiving furosemide. Each patient underwent in addition to their protocol for context, two types of MRU: 2D T2-weighted FSE (T2w-MRU) and 3D Gd T1-weighted GE (CE-MRU). Four segments were checked for each ureter. For the first part of the analysis, readers evaluated the whole image quality using a four points subjective scale and for the second part, they were asked to score separately each ureteral segment as present or absent. 1008 ureteral segments were checked. For the image quality, readers did not find any significant difference (3.8 ± 0.5 vs 3.6 ± 0.7, p value: 0.13) between MRU methods. The interobserver agreement was excellent with a κ correlation coefficient as high as 0.89 for T2w-MRU and 0.92 for CE

  14. Lattice effects in La1-xCaxMnO3 (x=0→1): Relationships between distortions, charge distribution, and magnetism

    International Nuclear Information System (INIS)

    Booth, C.H.; Bridges, F.; Kwei, G.H.; Lawrence, J.M.; Cornelius, A.L.; Neumeier, J.J.

    1998-01-01

    X-ray-absorption fine-structure measurements from the Mn and La K edges of samples of La 1-x Ca x MnO 3 (x=0→1) are presented as a function of temperature. In the insulating state, distortions of the Mn-O environment are found to be linear with calcium concentration x. These distortions are consistent with a model where individual Mn 3+ sites have strong Jahn-Teller (JT) distortions while Mn 4+ sites do not, although intermediate distortions are also possible. Comparisons to simulations of various possible bond length distributions show that these distortions are best modeled as a JT distortion, as opposed to charge disproportionation or other models. In the metallic state, at least ∼70% of the distortion is removed. A similar effect is seen in the Mn-Mn bond length distribution. The La-O bond length distribution does not change significantly through the ferromagnetic transition, constraining possible changes in the Mn-O-Mn bond angle to less than 0.5 degree. The changes in the MnO 6 distortion that occur near T c are also present (to a lesser degree) in an insulating sample with x=0.12. The functional relation between the MnO 6 distortions and the magnetization is determined, and compared to transport measurements. copyright 1998 The American Physical Society

  15. Comparative evaluation of gadoteridol versus gadopentetate dimeglumine for contrast-enhanced MRI in a rat brain glioma model at 1.5 and 3.0 T

    International Nuclear Information System (INIS)

    Ai Fei; Qi Jianpin; Li Xiaoming; Runge, Val M.; Morelli, John N.; Vu, Lan.; Cannel, Jeremy; Loynachan, Alan T.

    2010-01-01

    Objective: To compare gadoteridol and gadopentetate dimeglumine (Gd-DTPA) with respect to lesion enhancement in a rat brain glioma model at 1. 5 and 3.0 T. Methods: Glioma cells were injected into the brains of 42 male CDF (Fisher 344) rats through implanted cannula to create Glioma animal model. One week after implantation, all rats were randomly divided in to four groups which included 12, 10, 10, 10 rats. The comparisons included the contrast effect of gadoteridol versus gadopentetate dimeglumine at both 1.5 and 3.0 T. In addition, gadoteridol alone was evaluated by comparing the standard dose at both two field strengths and half dose at 3.0 T to a standard full dose at 1.5 T. Two MRI scans for different contrast agent injections were performed in each animal model with an interval of 24 hours. T 1 -weighted images were analyzed pre-contrast and at five time points (1, 3, 5, 7 and 9 min) post-contrast with respect to lesion signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast enhancement (CE). Student t test was used for statistics. Results: The mean SNR, CNR, and CE were respectively 54.4±3.2, 17.0±3.3 and 20.8±3.4 with gadopentetate dimeglumine versus 53.2±3.2, 17.2±3.1 and 20.8±3.2 with gadoteridol at 1.5 T at every postconuast time point (t=2.247, 0.403, 0.076, P>0.05). The mean SNR, CNR, and CE were respectively 94.8±7.1, 38.0±6.0 and 45.0±6.3 with gadopentetate dimeglumine versus 95.5±2.9, 37.2±2.7 and 45.6±2.8 with gadoteridol at 3.0 T (t= 0.303, 0.573, 0.357, P>0.05). No statistically significant differences were found in these parameters between the two agents at any time point at either field strength. Standard dose gadoteridol demonstrated significant improvements in SNR (51.9±3.0 at 1.5 T vs 86.1±4.9 at 3.0 T), CNR (15.6±3.0 at 1.5 T vs 27.4±5.0 at 3.0 T) and CE (18.6±3.0 at 1.5 T vs 37.3±5.3 at 3.0 T) at 3.0 T as compared to 1.5 T at every time post-contrast (t=36.227, 11.977, 17.106, P 0.05). Conclusions

  16. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    International Nuclear Information System (INIS)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai

    1995-01-01

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 ± 1.8mm) than that of control group (2-9mm, mean: 6.2 ± 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality

  17. High signal intensity of anterior pituitary gland on T1-weighted MR imaging in normal postpartum women

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Soon; Yang, Hak Seok; Chung, In Bai [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1995-01-15

    The purpose of this study is to evaluate the signal intensity and size of anterior pituitary gland in postpartum women, and to compare with those of control group. In 34 postpartum women (18-43 years, mean: 27 years) and another 35 control nonpregnant women (20-29 years, mean: 24 years), midsagittal T1-weighted MR images were obtained. The signal intensity and height of the anterior pituitary gland were compared between the post-partum and normal control groups. In postpartum women, the signal intensity of the anterior pituitary gland relative to the pons was higher than that of the control group. Pituitary gland height of postpartum women was higher (5-11. 8mm, mean 8.18 {+-} 1.8mm) than that of control group (2-9mm, mean: 6.2 {+-} 1.7mm). It is concluded that the hyperintensity of the anterior pituitary gland on T1-weighted image is a normal finding in postpartum women, which is useful in differentiation from pituitary abnormality.

  18. Synthesis, crystal structure, and properties of KSbO{sub 3}-type Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11}

    Energy Technology Data Exchange (ETDEWEB)

    Li Manrong; Retuerto, Maria; Bok Go, Yong; Emge, Thomas J. [Department of Chemistry and Chemical Biology, Rutgers, State University of New Jersey, 610 Taylor Road, Piscataway, NJ 08854 (United States); Croft, Mark; Ignatov, Alex [Department of Physics and Astronomy, Rutgers, State University of New Jersey, 136 Frelinghuysen Road, Piscataway, NJ 08854 (United States); Ramanujachary, Kandalam V. [Department of Chemistry and Biochemistry, Rowan University, 210 Mullica Hill Road, Glassboro, NJ 08028 (United States); Dachraoui, Walid; Hadermann, Joke [EMAT, University of Antwerp, Groenenborgerlaan 171, B-2020 Antwerp (Belgium); Tang Meibo; Zhao Jingtai [Key Laboratory of Transparent Opto-Functional Inorganic Materials of Chinese Academy of Sciences, Shanghai Institute of Ceramics, Shanghai 200050 (China); Greenblatt, Martha, E-mail: martha@rutchem.rutgers.edu [Department of Chemistry and Chemical Biology, Rutgers, State University of New Jersey, 610 Taylor Road, Piscataway, NJ 08854 (United States)

    2013-01-15

    Single crystals of Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11} were prepared from NaCl+KCl flux. This compound adopts KSbO{sub 3}-type crystal structure as evidenced by electron and single crystal X-ray diffraction analysis. The three-dimensional channel structure is formed by corner-sharing octahedral (Mn{sub 0.63}Te{sub 0.37}){sub 2}O{sub 10} dimers and two identical (Bi1){sub 4}(Bi2){sub 2} interpenetrating lattices. The intra-dimer Mn/Te-Mn/Te distances in Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11} are short and are consistent with weak metal-metal interactions. The mixed oxidation state of manganese and the edge-sharing octahedral features are confirmed by X-ray near edge absorption spectroscopy measurements, which indicate Bi{sub 3}(Mn{sup III}{sub 1.1}Mn{sup IV}{sub 0.8})Te{sup VI}{sub 1.1}O{sub 11} with 57.7% Mn{sup 3+} and 42.3% Mn{sup 4+}. The partial substitution of Te for Mn perturbs long-range magnetic interactions, thereby destroying the ferromagnetic ordering found in Bi{sub 3}Mn{sub 3}O{sub 11} (T{sub C}=150 K). - Graphical abstract: Single crystal of Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11} was grown from NaCl+KCl binary flux, suggesting that the high pressure Bi{sub 3}Mn{sub 3}O{sub 11} phase can be stabilized by partial substitution of Mn by Te at ambient pressure. Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11} adopts a typical three dimensional KSbO{sub 3}-type crystal structure with three interpenetrating lattices and weak intra-dimmer metal-metal interaction caused by the d electrons of Mn. The edge-shared (Mn{sub 0.63}Te{sub 0.37}){sub 2}O{sub 10} octahedral dimer and mixed oxidation state of manganese (Bi{sub 3}(Mn{sup III}{sub 1.1}Mn{sup IV}{sub 0.8})Te{sup VI}{sub 1.1}O{sub 11} with 57.7% Mn{sup 3+} and 42.3% Mn{sup 4+}) features were evidenced by X-ray absorption near edge spectroscopy. Compared with Bi{sub 3}Mn{sub 3}O{sub 11}, the Te substituted Bi{sub 3}Mn{sub 1.9}Te{sub 1.1}O{sub 11} relaxes the crystal structure, but destroys the long

  19. Lithium Diffusion and Magnetism in Battery Cathode Material LixNi1/3Co1/3Mn1/3O2

    International Nuclear Information System (INIS)

    Månsson, M; Prša, K; Nozaki, H; Sugiyama, J; Wikberg, J M; Sassa, Y; Dahbi, M; Kamazawa, K; Sedlak, K; Watanabe, I

    2014-01-01

    We have studied low-temperature magnetic properties as well as high-temperature lithium ion diffusion in the battery cathode materials Li x Ni 1/3 Co 1/3 Mn 1/3 O 2 by the use of muon spin rotation/relaxation. Our data reveal that the samples enter into a 2D spin-glass state below T SG ≈ 12 K. We further show that lithium diffusion channels become active for TT diff ∼ 125 K where the Li-ion hopping-rate [v(T)] starts to increase exponentially. Further, v(T) is found to fit very well to an Arrhenius type equation and the activation energy for the diffusion process is extracted as E a ≈ 100 meV

  20. Magnetic and ultrasonic studies on double layered CMR manganite La1.2Sr1.8Mn2O7

    International Nuclear Information System (INIS)

    Reddy, Y.S.; Vishnuvardhan Reddy, C.

    2014-01-01

    Magnetic and ultrasonic studies were done on La 1.2 Sr 1.8 Mn 2 O 7 to understand the correlation between its magnetic and ultrasonic transitions. The sample transforms from paramagnetic-insulator to ferromagnetic-metallic state at T c ≈124 K. The significant hardening in longitudinal sound velocity measurements (below T c ) is attributed to the coupling between ferromagnetic spins and longitudinal acoustic phonons. (author)

  1. Sensitivity of susceptibility-weighted imaging in detecting developmental venous anomalies and associated cavernomas and microhemorrhages in children

    International Nuclear Information System (INIS)

    Young, Allen; Bosemani, Thangamadhan; Goel, Reema; Huisman, Thierry A.G.M.; Poretti, Andrea

    2017-01-01

    Developmental venous anomalies (DVA) are common neuroimaging abnormalities that are traditionally diagnosed by contrast-enhanced T1-weighted images as the gold standard. We aimed to evaluate the sensitivity of SWI in detecting DVA and associated cavernous malformations (CM) and microhemorrhages in children in order to determine if SWI may replace contrast-enhanced MRI sequences. Contrast-enhanced T1-weighted images were used as diagnostic gold standard for DVA. The presence of DVA was qualitatively assessed on axial SWI and T2-weighted images by an experienced pediatric neuroradiologist. In addition, the presence of CM and microhemorrhages was evaluated on SWI and contrast-enhanced T1-weighted images. Fifty-seven children with DVA (34 males, mean age at neuroimaging 11.2 years, range 1 month to 17.9 years) were included in this study. Forty-nine out of 57 DVA were identified on SWI (sensitivity of 86%) and 16 out of 57 DVA were detected on T2-weighted images (sensitivity of 28.1%). General anesthesia-related changes in brain hemodynamics and oxygenation were most likely responsible for the majority of SWI false negative. CM were detected in 12 patients on axial SWI, but only in six on contrast-enhanced T1-weighted images. Associated microhemorrhages could be identified in four patients on both axial SWI and contrast-enhanced T1-weighted images, although more numerous and conspicuous on SWI. SWI can identify DVA and associated cavernous malformations and microhemorrhages with high sensitivity, obviating the need for contrast-enhanced MRI sequences. (orig.)

  2. Sensitivity of susceptibility-weighted imaging in detecting developmental venous anomalies and associated cavernomas and microhemorrhages in children

    Energy Technology Data Exchange (ETDEWEB)

    Young, Allen; Bosemani, Thangamadhan; Goel, Reema; Huisman, Thierry A.G.M. [The Johns Hopkins School of Medicine, Charlotte R. Bloomberg Children' s Center, Division of Pediatric Radiology and Pediatric Neuroradiology, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Poretti, Andrea [The Johns Hopkins School of Medicine, Charlotte R. Bloomberg Children' s Center, Division of Pediatric Radiology and Pediatric Neuroradiology, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Kennedy Krieger Institute, Department of Neurogenetics, Baltimore, MD (United States)

    2017-08-15

    Developmental venous anomalies (DVA) are common neuroimaging abnormalities that are traditionally diagnosed by contrast-enhanced T1-weighted images as the gold standard. We aimed to evaluate the sensitivity of SWI in detecting DVA and associated cavernous malformations (CM) and microhemorrhages in children in order to determine if SWI may replace contrast-enhanced MRI sequences. Contrast-enhanced T1-weighted images were used as diagnostic gold standard for DVA. The presence of DVA was qualitatively assessed on axial SWI and T2-weighted images by an experienced pediatric neuroradiologist. In addition, the presence of CM and microhemorrhages was evaluated on SWI and contrast-enhanced T1-weighted images. Fifty-seven children with DVA (34 males, mean age at neuroimaging 11.2 years, range 1 month to 17.9 years) were included in this study. Forty-nine out of 57 DVA were identified on SWI (sensitivity of 86%) and 16 out of 57 DVA were detected on T2-weighted images (sensitivity of 28.1%). General anesthesia-related changes in brain hemodynamics and oxygenation were most likely responsible for the majority of SWI false negative. CM were detected in 12 patients on axial SWI, but only in six on contrast-enhanced T1-weighted images. Associated microhemorrhages could be identified in four patients on both axial SWI and contrast-enhanced T1-weighted images, although more numerous and conspicuous on SWI. SWI can identify DVA and associated cavernous malformations and microhemorrhages with high sensitivity, obviating the need for contrast-enhanced MRI sequences. (orig.)

  3. Fabrication and evaluation of tumor-targeted positive MRI contrast agent based on ultrasmall MnO nanoparticles.

    Science.gov (United States)

    Huang, Haitao; Yue, Tao; Xu, Ke; Golzarian, Jafar; Yu, Jiahui; Huang, Jin

    2015-07-01

    Gd(III) chelate is currently used as positive magnetic resonance imaging (MRI) contrast agent in clinical diagnosis, but generally induces the risk of nephrogenic systemic fibrosis (NSF) due to the dissociated Gd(3+) from Gd(III) chelates. To develop a novel positive MRI contrast agent with low toxicity and high sensitivity, ultrasmall MnO nanoparticles were PEGylated via catechol-Mn chelation and conjugated with cRGD as active targeting function to tumor. Particularly, the MnO nanoparticles with a size of ca. 5nm were modified by α,β-poly(aspartic acid)-based graft polymer containing PEG and DOPA moieties and, meanwhile, conjugated with cRGD to produce the contrast agent with a size of ca. 100nm and a longitudinal relaxivity (r1) of 10.2mM(-1)S(-1). Such nanoscaled contrast agent integrated passive- and active-targeting function to tumor, and its efficient accumulation behavior in tumor was verified by in vivo distribution study. At the same time, the PEG moiety played a role of hydrophilic coating to improve the biocompatibility and stability under storing and physiological conditions, and especially might guarantee enough circulation time in blood. Moreover, in vivo MRI revealed a good and long-term effect of enhancing MRI signal for as-fabricated contrast agent while cell viability assay proved its acceptable cytotoxicity for MRI application. On the whole, the as-fabricated PEGylated and cRGD-functionalized contrast agent based on ultrasmall MnO nanoparticles showed a great potential to the T1-weighted MRI diagnosis of tumor. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  4. Characterization of chondroid matrix-forming sarcomas: gadolinium-enhanced and diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Cheng Kebin; Zhang Jing; Qu Hui; Zhang Wei; Liang Wei; Li Xiaosong; Cheng Xiaoguang; Gong Lihua

    2010-01-01

    Objective: To study the Gadolinium-enhanced MRI and diffusion weighted imaging (DWI) characteristics of the chondroid matrix-forming sarcomas. Methods: Contrast-enhanced MRI and DWI were performed in 14 cases of chondroid matrix-forming sarcomas (10 chondrosarcomas, 4 chondroblastic osteosarcomas) and 13 cases of other types of osteosarcomas. DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager with two different b values of 0 and 700 s/mm 2 . The apparent diffusion coefficient (ADC) values were obtained in GE Functiontool software. The contrast-enhancement pattern was evaluated and the ADC values of chondroid matrix-forming sarcomas was compared with that of other types of osteosareoma. Independent sample t-test was performed to evaluate the difference of ADC values between the group of chondroid matrix-forming sarcoma and the group of other types of osteosarcoma. In addition, nonparametric test was used to assess the difference of ADC values between the chondrosarcoma and the chondroblastic osteosarcoma. P value less than 0.05 was considered to represent a statistical significance. Results: For 14 cases of chondroid matrix-forming sarcomas, peripheral enhancement was found in all cases, septonodular enhancement was identified in 12 cases. While 13 cases of other types of osteosarcomas demonstrated heterogeneous enhancement. The mean ADC value of chondroid matrix-forming sarcomas [(2.56±0.35) x 10 -3 mm 2 /s] was significantly higher than that of other types of osteosarcoma [(1.16 ± 0.20) x 10 -3 mm 2 /s] (t=12.704, P<0.01). There was no significant difference in the ADC value between the chondrosarcoma and the chondroblastic osteosarcoma (Z=0.507, P=0.959). Conclusion: Contrast-enhanced MRI and DWI can improve differentiation between chondroid matrix-forming sarcomas and other types of osteosarcomas. (authors)

  5. Leaching process for recovering valuable metals from the LiNi1/3Co1/3Mn1/3O2 cathode of lithium-ion batteries.

    Science.gov (United States)

    He, Li-Po; Sun, Shu-Ying; Song, Xing-Fu; Yu, Jian-Guo

    2017-06-01

    In view of the importance of environmental protection and resource recovery, recycling of spent lithium-ion batteries (LIBs) and electrode scraps generated during manufacturing processes is quite necessary. An environmentally sound leaching process for the recovery of Li, Ni, Co, and Mn from spent LiNi 1/3 Co 1/3 Mn 1/3 O 2 -based LIBs and cathode scraps was investigated in this study. Eh-pH diagrams were used to determine suitable leaching conditions. Operating variables affecting the leaching efficiencies for Li, Ni, Co, and Mn from LiNi 1/3 Co 1/3 Mn 1/3 O 2 , such as the H 2 SO 4 concentration, temperature, H 2 O 2 concentration, stirring speed, and pulp density, were investigated to determine the most efficient conditions for leaching. The leaching efficiencies for Li, Ni, Co, and Mn reached 99.7% under the optimized conditions of 1M H 2 SO 4 , 1vol% H 2 O 2 , 400rpm stirring speed, 40g/L pulp density, and 60min leaching time at 40°C. The leaching kinetics of LiNi 1/3 Co 1/3 Mn 1/3 O 2 were found to be significantly faster than those of LiCoO 2 . Based on the variation in the weight fraction of the metal in the residue, the "cubic rate law" was revised as follows: θ(1-f) 1/3 =(1-kt/r 0 ρ), which could characterize the leaching kinetics optimally. The activation energies were determined to be 64.98, 65.16, 66.12, and 66.04kJ/mol for Li, Ni, Co, and Mn, respectively, indicating that the leaching process was controlled by the rate of surface chemical reactions. Finally, a simple process was proposed for the recovery of valuable metals from spent LiNi 1/3 Co 1/3 Mn 1/3 O 2 -based LIBs and cathode scraps. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Reentrant spin glass behavior in polycrystalline La0.7Sr0.3Mn1-XFeXO 3

    Directory of Open Access Journals (Sweden)

    Xavier Jr. M.M.

    2004-01-01

    Full Text Available The magnetic and transport properties of the compound La0.7Sr0.3Mn1-xFe xO 3 (0.1 < x <0.4 have been studied by means of electrical resistivity, AC magnetic susceptibility, and DC magnetization. At low concentrations (x <0.1, the system displays essentially para-to-ferromagnetic transitions as the temperature is decreased, although a decrease in the magnetic moment has been observed in previous studies at temperatures a little below T C. This ferromagnetism is explained by double exchange theory in terms of the formation of Mn+3/Mn+4 ions pairs in the system. At concentrations in the range 0.1 < x <0.4 the system is more complex. Increased Fe doping not only weakens the ferromagnetic (FM order and augments the resistivity of the samples, but also induces the appearance of a reentrant spin glass phase at low temperatures (T < 60 K. Irreversibility of the magnetization measured with zero field cooling and with field cooling has been observed. In addition, the AC susceptibility peak position varies with frequency. All these effects are characteristic of spin glass behavior. The results have been interpreted based in an increase of frustration due to increasing competition between FM Mn+3/Mn+4 interactions and antiferromagnetic interactions between ions at the boundaries of Fe clusters.

  7. Ultrasmall PdmMn1-mOx binary alloyed nanoparticles on graphene catalysts for ethanol oxidation in alkaline media

    Science.gov (United States)

    Ahmed, Mohammad Shamsuddin; Park, Dongchul; Jeon, Seungwon

    2016-03-01

    A rare combination of graphene (G)-supported palladium and manganese in mixed-oxides binary alloyed catalysts (BACs) have been synthesized with the addition of Pd and Mn metals in various ratios (G/PdmMn1-mOx) through a facile wet-chemical method and employed as an efficient anode catalyst for ethanol oxidation reaction (EOR) in alkaline fuel cells. The as prepared G/PdmMn1-mOx BACs have been characterized by several instrumental techniques; the transmission electron microscopy images show that the ultrafine alloyed nanoparticles (NPs) are excellently monodispersed onto the G. The Pd and Mn in G/PdmMn1-mOx BACs have been alloyed homogeneously, and Mn presents in mixed-oxidized form that resulted by X-ray diffraction. The electrochemical performances, kinetics and stability of these catalysts toward EOR have been evaluated using cyclic voltammetry in 1 M KOH electrolyte. Among all G/PdmMn1-mOx BACs, the G/Pd0.5Mn0.5Ox catalyst has shown much superior mass activity and incredible stability than that of pure Pd catalysts (G/Pd1Mn0Ox, Pd/C and Pt/C). The well dispersion, ultrafine size of NPs and higher degree of alloying are the key factor for enhanced and stable EOR electrocatalysis on G/Pd0.5Mn0.5Ox.

  8. MN Lup: X-RAYS FROM A WEAKLY ACCRETING T TAURI STAR

    International Nuclear Information System (INIS)

    Günther, H. M.; Wolk, S. J.; Wolter, U.; Robrade, J.

    2013-01-01

    Young T Tauri stars (TTS) are surrounded by an accretion disk, which over time disperses due to photoevaporation, accretion, and possibly planet formation. The accretion shock on the central star produces an UV/optical veiling continuum, line emission, and X-ray signatures. As the accretion rate decreases, the impact on the central star must change. In this article we study MN Lup, a young star where no indications of a disk are seen in IR observations. We present XMM-Newton and VLT/UVES observations, some of them taken simultaneously. The X-ray data show that MN Lup is an active star with L X /L bol close to the saturation limit. However, we find high densities (n e > 3 × 10 10 cm –3 ) in the X-ray grating spectrum. This can be well fitted using an accretion shock model with an accretion rate of 2 × 10 –11 M ☉ yr –1 . Despite the simple Hα line profile which has a broad component, but no absorption signatures as typically seen on accreting TTS, we find rotational modulation in Ca II K and in photospheric absorption lines. These line profile modulations do not clearly indicate the presence of a localized hot accretion spot on the star. In the Hα line we see a prominence in absorption about 2R * above the stellar surface—the first of its kind on a TTS. MN Lup is also the only TTS where accretion is seen, but no dust disk is detected that could fuel it. We suggest that MN Lup presents a unique and short-lived state in the disk evolution. It may have lost its dust disk only recently and is now accreting the remaining gas at a very low rate.

  9. Enhanced exchange anisotropy in IrMn/CoFeB systems and its correlation with uncompensated interfacial spins

    DEFF Research Database (Denmark)

    Du, Yuqing; Pan, Genhua; Moate, Roy

    2010-01-01

    Bottom pinned exchange bias systems of IrMn/CoFe and IrMn/CoFeB on CoFe seed layers were studied. Enhanced exchange anisotropy has been observed for IrMn/CoFeB samples annealed at 350 °C. The ferromagnetic and antiferromagnetic layers of both samples are polycrystalline and textured {110} for the...

  10. IVIM diffusion-weighted imaging of the liver at 3.0 T: Comparison with 1.5 T

    Science.gov (United States)

    Cui, Yong; Dyvorne, Hadrien; Besa, Cecilia; Cooper, Nancy; Taouli, Bachir

    2015-01-01

    Purpose To compare intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) of the liver between 1.5 T and 3.0 T in terms of parameter quantification and inter-platform reproducibility. Materials and methods In this IRB approved prospective study, 19 subjects (17 patients with chronic liver disease and 2 healthy volunteers) underwent two repeat scans at 1.5 T and 3.0 T. Each scan included IVIM DWI using 16 b values from 0 to 800 s/mm2. A single observer measured IVIM parameters for each platform and estimated signal to noise ratio (eSNR) at b0, 200, 400 and 800 s/mm2. Wilcoxon paired tests were used to compare liver eSNR and IVIM parameters. Inter-platform reproducibility was assessed by calculating within-subject coefficient of variation (CV) and Bland–Altman limits of agreement. An ice water phantom was used to test ADC variability between the two MRI systems. Results The mean invitro difference in ADC between the two platforms was 6.8%. eSNR was significantly higher at 3.0T for all selected b values (p = 0.006–0.020), except for b0 (p = 0.239). Liver IVIM parameters were significantly different between 1.5 T and 3.0 T (p = 0.005–0.044), except for ADC (p = 0.748). The inter-platform reproducibility of true diffusion coefficient (D) and ADC were good, with mean CV of 10.9% and 11.1%, respectively. Perfusion fraction (PF) and pseudodiffusion coefficient (D*) showed more limited inter-platform reproducibility (mean CV of 22.6% for PF and 46.9% for D*). Conclusion Liver D and ADC values showed good reproducibility between 1.5 T and 3.0 T platforms; while there was more variability in PF, and large variability in D* parameters between the two platforms. These findings may have implications for drug trials assessing the role of IVIM DWI in tumor response and liver fibrosis. PMID:26393236

  11. High incidence of microbleeds in hemodialysis patients detected by T2*-weighted gradient-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yokoyama, Shunichi; Uomizu, Kenji; Kajiya, Yoriko; Tajitsu, Kenichiro; Kusumoto, Kazuhiro; Hirano, Hirofumi

    2005-01-01

    The incidence and characteristics of microbleeds in hemodialysis (HD) patients were investigated to elucidate the clinical significance with T 2 * -weighted gradient-echo magnetic resonance (MR) imaging. The 57 patients with chronic renal failure maintained by HD had no previous history of stroke. The control group consisted of 53 patients without previous history of stroke or chronic renal failure. The incidence and the number of microbleeds were assessed in the HD and control groups. The findings of microbleeds with T 2 * -weighted gradient-echo MR imaging were compared with those of T 1 - and T 2 -weighted MR imaging in HD patients. The incidence of microbleeds was significantly greater in the HD patients compared with the control patients. T 2 * -weighted gradient-echo imaging revealed a total of 44 microbleeds in 11 HD patients. T 2 -weighted imaging demonstrated 13 of 44 microbleeds as hyperintensity, whereas T 1 -weighted imaging demonstrated 12 lesions as hypointensity. T 2 - and T 1 -weighted imagings did not demonstrate any findings in 31 and 32 lesions, respectively. T 2 * -weighted gradient-echo MR imaging is effective to detect microbleeds which may be a predictor of intracerebral hemorrhage in HD patients and should be included in the protocol for the study of cerebrovascular disease, because T 2 - and T 1 -weighted MR imaging recognizes microbleeds as lacunar infarction. (author)

  12. Relation of Giant Thermo-EMF, Magnetothermo-EMF, Magnetoresistance, and Magnetization to Magnetic Impurity States in Manganites Nd(1- x)Sr x MnO3 and Sm(1- x)Sr x MnO3

    Science.gov (United States)

    Koroleva, L. I.; Batashev, I. K.; Morozov, A. S.; Balbashov, A. M.; Szymczak, H.; Slawska-Waniew, A.

    2018-02-01

    Thermo-EMF, magnetothermo-EMF, magnetoresistance, and magnetization of single-crystal samples of Nd(1- x)Sr x MnO3 and Sm(1- x)Sr x MnO3 with 0 ≤ x ≤ 0.3 have been studied experimentally. A sharp increase in the thermo-EMF and giant magnetothermo-EMF and magnetoresistance has been observed near the Curie point T C in compounds with 0.15 ≤ x ≤ 0.3. At the same time, no peculiarities have been found in compositions with x = 0. Since compounds with x > 0 consist of ferromagnetic clusters of the ferron type that reside in an antiferromagnetic A-type matrix, this means that the sharp increase in the thermo-EMF near T C is caused by ferrons. Indeed, the disappearance of ferrons due to a magnetic field or heating above T C leads to an abrupt decrease in the thermo-EMF. Therefore, thermo-EMF in alloyed magnetic semiconductors has been determined by the impurity concentration and the sample volume.

  13. Fat-saturated post gadolinium T1 imaging of the brain in multiple sclerosis

    International Nuclear Information System (INIS)

    Al-Saeed, Osama; Sheikh, Mehraj; Ismail, Mohammed; Athyal, Reji

    2011-01-01

    Background Magnetic resonance imaging (MRI) is of vital importance in the diagnosis and follow-up of patients with multiple sclerosis (MS). Imaging sequences better demonstrating enhancing lesions can help in detecting active MS plaques. Purpose To evaluate the role of fat-saturated gadolinium-enhanced T1-weighted (T1W) images of the brain in MS and to assess the benefit of performing this additional sequence in the detection of enhancing lesions. Material and Methods In a prospective study over a six-month period, 70 consecutive patients with clinically diagnosed MS were enrolled. These constituted 14 male and 56 female patients between the ages of 21 and 44 years. All the patients underwent brain MRIs on a 1.5 Tesla Magnet. Gadolinium-enhanced T1 images with and without fat saturation were compared and results were recorded and analyzed using a conspicuity score and McNemar test. Results There were a total of 157 lesions detected in 70 patients on post-contrast T1W fat-saturated images compared with 139 lesions seen on the post-contrast T1W fast spin-echo (FSE) images. This was because 18 of the lesions (11.5%) were only seen on the fat-saturated images. In addition, 15 lesions were more conspicuous on the fat saturation sequence (9.5%). The total conspicuity score obtained, including all the lesions, was 2.24 +/-0.60 (SD). Using the two-tailed McNemar test for quantitative analysis, the P value obtained was <0.0001. Conclusion T1W fat-saturated gadolinium-enhanced images show better lesion enhancement than T1W images without fat saturation

  14. The Nd-Mn exchange interaction, low temperature specific heat and magnetism of Nd{sub 2/3}Ca{sub 1/3}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Beznosov, Anatoly [B. Verkin Institute for Low Temperature Physics and Engineering NASU, 47 Lenin Avenue, Kharkov 61103 (Ukraine); Fertman, Elena, E-mail: fertman@ilt.kharkov.ua [B. Verkin Institute for Low Temperature Physics and Engineering NASU, 47 Lenin Avenue, Kharkov 61103 (Ukraine); Desnenko, Vladimir [B. Verkin Institute for Low Temperature Physics and Engineering NASU, 47 Lenin Avenue, Kharkov 61103 (Ukraine); Kajnakova, Marcela; Feher, Alexander [Centre of Low Temperature Physics of the Faculty of Science UPJS and IEP SAS, Park Angelinum 9, 04154 Kosice (Slovakia)

    2011-10-15

    The low temperature specific heat and magnetic characteristics of Nd{sub 2/3}Ca{sub 1/3}MnO{sub 3} perovskite are studied in a wide range of magnetic fields (up to 9 T). Temperature dependent specific heat data show a broadened Schottky-like anomaly below 20 K caused by splitting of the Nd{sup 3+} ions ground-state doublet in the effective molecular field H{sub ex}, determined by exchange interaction between Nd and Mn spin systems supplemented by an applied external magnetic field. Existence of the splitting at zero magnetic field and expressed field dependence is the evidence of a strong exchange coupling between Nd and Mn magnetic subsystems. The Nd-ions magnetic ordering leads to an additional contribution to the magnetic moment of the system below 30 K, producing anomalies of the magnetic loss and field-cooled and zero-field-cooled magnetizations. The observed broadened Schottky-like anomalies are fitted for each applied magnetic field by the sum of three Schottky functions. Applied magnetic field extends the anomaly region and shifts it to higher temperatures. Splitting of the higher crystal field Kramers doublets gives an additional contribution to the heat capacity in magnetic fields. The ground state doublet g-factors g{sub ||} and g{sub perpendicular} were estimated to be 3.4 and 2.2, respectively, and H{sub ex} was estimated to be 9 T. The Nd{sup 3+} ions magnetic moment estimated from the magnetization data agrees with the value obtained from the specific heat data. - Highlights: > Low temperature specific heat of Nd{sub 2/3}Ca{sub 1/3}MnO{sub 3} has been measured in magnetic fields up to 9 T. > Schottky-like anomalies are fitted for each magnetic field by a sum of three Schottky functions. > An effective magnetic field of the Mn spin system on Nd ion has been estimated as H{sub ex}=9 T. > Nd{sup 3+} ground-state g-factors have been estimated as g{sub ||}=3.4 and g{sub perpendicular} =2.2. > Magnetic ordering of the Nd subsystem has been revealed below

  15. Enhancement of D-T reaction rate due to D-T contact

    International Nuclear Information System (INIS)

    Hitoki, Shigehisa; Ogasawara, Masatada; Aono, Osamu.

    1979-09-01

    The reaction rate that is appropriate for magnetized nonuniform plasma is numerically calculated to investigate the enhancement of the D-T reaction rate. Spatial separation of the guiding center distributions of D and T enhances the reaction rate. Cases of several guiding center configurations are investigated. The largest enhancement is obtained, when both guiding center distributions are delta-functions which are separated by a length that corresponds to the Gamow peak energy. As compared with the case of no separation of D and T, the maximum enhancing factors obtained are 2.3 for total reaction rate and 1.6 for local reaction rate. Cases of the guiding center distributions with finite widths are also investigated. (author)

  16. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  17. T-Bet Enhances Regulatory T Cell Fitness and Directs Control of Th1 Responses in Crescentic GN.

    Science.gov (United States)

    Nosko, Anna; Kluger, Malte A; Diefenhardt, Paul; Melderis, Simon; Wegscheid, Claudia; Tiegs, Gisa; Stahl, Rolf A K; Panzer, Ulf; Steinmetz, Oliver M

    2017-01-01

    Th1 cells are central pathogenic mediators of crescentic GN (cGN). Mechanisms responsible for Th1 cell downregulation, however, remain widely unknown. Recently, it was proposed that activation of the Th1-characteristic transcription factor T-bet optimizes Foxp3 + regulatory T (Treg) cells to counteract Th1-type inflammation. Because very little is known about the role of T-bet + Treg1 cells in inflammatory diseases, we studied the function of these cells in the nephrotoxic nephritis (NTN) model of cGN. The percentage of Treg1 cells progressively increased in kidneys of nephritic wild-type mice during the course of NTN, indicating their functional importance. Notably, naïve Foxp3 Cre xT-bet fl/fl mice, lacking Treg1 cells, showed spontaneous skewing toward Th1 immunity. Furthermore, absence of Treg1 cells resulted in aggravated NTN with selectively dysregulated renal and systemic Th1 responses. Detailed analyses of Treg cells from Foxp3 Cre xT-bet fl/fl mice revealed unaltered cytokine production and suppressive capacity. However, in competitive cotransfer experiments, wild-type Treg cells outcompeted T-bet-deficient Treg cells in terms of population expansion and expression levels of Foxp3, indicating that T-bet expression is crucial for general Treg fitness. Additionally, T-bet-deficient Treg cells lacked expression of the Th1-characteristic trafficking receptor CXCR3, which correlated with significant impairment of renal Treg infiltration. In summary, our data indicate a new subtype of Treg cells in cGN. These Treg1 cells are characterized by activation of the transcription factor T-bet, which enhances the overall fitness of these cells and optimizes their capacity to downregulate Th1 responses by inducing chemokine receptor CXCR3 expression. Copyright © 2016 by the American Society of Nephrology.

  18. Transition Metal Complexes of Cr, Mo, W and Mn Containing η1(S)-2,5-Dimethylthiophene, Benzothiophene and Dibenzothiophene Ligands

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, Michael [Iowa State Univ., Ames, IA (United States)

    2000-09-21

    The UV photolysis of hexanes solutions containing the complexes M(CO)6 (M=Cr, Mo, W) or CpMn(CO)3 (Cp=η5-C5H5) and excess thiophene (T*) (T*=2,5-dimethylthiophene (2,5-Me2T), benzothiophene (BT), and dibenzothiophene (DBT)) produces the η1(S)-T* complexes (CO)5M(η1(S)-T*) 1-8 or Cp(CO)2Mn1(S)-T*)9-11, respectively. However, when T*=DBT, and M=Mo, a mixture of two products result which includes the η1(S)-DBT complex (CO)5Mo(η1(S)-DBT) 4a and the unexpected π-complex (CO)3Mo(η{sup 6}-DBT) 4b as detected by 1H NMR. The liability of the η1(S)-T* ligands is illustrated by the rapid displacement of DBT in the complex (CO)5W(η1(S)-DBT) (1) by THF, and also in the complexes (CO)5Cr(η1(S)-DBT) (5) and CpMn(CO)21(S)-DBT) (9) by CO (1 atm) at room temperature. Complexes 1-11 have been characterized spectroscopically (1H NMR, IR) and when possible isolated as analytically pure solids (elemental analysis, EIMS). Single crystal, X-ray structural determinations are reported for (Cη)5W(η1(S)-DBT) and Cp(CO)2Mn1(S)-DBT).

  19. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  20. Size-dependent structure and magnetic properties of DyMnO3 nanoparticles

    International Nuclear Information System (INIS)

    Cai, Xuan; Shi, Lei; Zhou, Shiming; Zhao, Jiyin; Guo, Yuqiao; Wang, Cailin

    2014-01-01

    The structure and magnetic properties of orthorhombic DyMnO 3 nanoparticles with different particle sizes are investigated in this paper. With decreasing particle size, all the lattice parameters a, b, and c gradually decrease, whereas the orthorhombic distortion increases. Magnetic measurements reveal that the antiferromagnetic interaction of Mn ions is weakened due to the decrease in Mn-O-Mn bond angle. Above a critical field H*, DyMnO 3 undergoes a field-induced metamagnetic transition at 4 K, which is related to the spin reversal of Dy moments. The critical field H* increases monotonically with size reduction, indicating an enhancement of the antiferromagnetic interaction of Dy ions due to the decreased distance between rare earth ions. The magnetization at 4 K and 5 T, i.e., M(4 K, 5 T) shows a non-monotonic variation with particle size d, i.e., M(4 K, 5 T) initially increases with size reduction but decreases again for d < 68 nm. A modified core-shell model, in which the ferromagnetic ordering (Dy magnetic structure) and antiferromagnetic ordering (Mn magnetic structure) coexist in the core, is proposed to explain this behavior.

  1. Zn-Doped LiNi1/3Co1/3Mn1/3O2 Composite as Cathode Material for Lithium Ion Battery: Preparation, Characterization, and Electrochemical Properties

    Directory of Open Access Journals (Sweden)

    Han Du

    2015-01-01

    Full Text Available Zn-doped LiNi1/3Co1/3Mn1/3O2 composite, Li(Ni1/3Co1/3Mn1/31–xZnxO2 (x = 0.02; 0.05; 0.08, is synthesized by the sol-gel method. The crystal structure, morphology, and electrochemical performance are investigated via X-ray diffraction (XRD, scanning electron microscope (SEM, cyclic voltammetry (CV, and constant current charge/discharge experiment. The result reveals that Zn-doping cathode material can reach the initial charge/discharge capacity of 188.8/162.9 mAh·g−1 for Li(Ni1/3Co1/3Mn1/30.98Zn0.02O2 and 179.0/154.1 mAh·g−1 for Li(Ni1/3Co1/3Mn1/30.95Zn0.05O2 with the high voltage of 4.4 V at 0.1 C. Furthermore, the capacity retention of Li(Ni1/3Co1/3Mn1/30.98Zn0.02O2 is 95.1% at 0.5 C after 50 cycles at room temperature. The improved electrochemical properties of Zn-doped LiNi1/3Co1/3Mn1/3O2 are attributed to reduced electrode polarization, enhanced capacity reversibility, and excellent cyclic performance.

  2. NOD1 cooperates with TLR2 to enhance T cell receptor-mediated activation in CD8 T cells.

    Directory of Open Access Journals (Sweden)

    Blandine C Mercier

    Full Text Available Pattern recognition receptors (PRR, like Toll-like receptors (TLR and NOD-like receptors (NLR, are involved in the detection of microbial infections and tissue damage by cells of the innate immune system. Recently, we and others have demonstrated that TLR2 can additionally function as a costimulatory receptor on CD8 T cells. Here, we establish that the intracytosolic receptor NOD1 is expressed and functional in CD8 T cells. We show that C12-iEDAP, a synthetic ligand for NOD1, has a direct impact on both murine and human CD8 T cells, increasing proliferation and effector functions of cells activated via their T cell receptor (TCR. This effect is dependent on the adaptor molecule RIP2 and is associated with an increased activation of the NF-κB, JNK and p38 signaling pathways. Furthermore, we demonstrate that NOD1 stimulation can cooperate with TLR2 engagement on CD8 T cells to enhance TCR-mediated activation. Altogether our results indicate that NOD1 might function as an alternative costimulatory receptor in CD8 T cells. Our study provides new insights into the function of NLR in T cells and extends to NOD1 the recent concept that PRR stimulation can directly control T cell functions.

  3. Authentically radiolabelled Mn(II) complexes as bimodal PET/MR tracers

    Energy Technology Data Exchange (ETDEWEB)

    Vanasschen, Christian; Brandt, Marie; Ermert, Johannes [Institute of Neuroscience and Medicine, INM-5 - Nuclear Chemistry, Forschungszentrum Jülich (Germany); Neumaier, Bernd [Institute for Radiochemistry and Experimental Molecular Imaging, Medical Clinics, University of Cologne (Germany); Coenen, Heinz H [Institute of Neuroscience and Medicine, INM-5 - Nuclear Chemistry, Forschungszentrum Jülich (Germany)

    2015-05-18

    The development of small molecule bimodal PET/MR tracers is mainly hampered by the lack of dedicated preparation methods. Authentic radiolabelling of MR contrast agents ensures easy access to such probes: a ligand, chelating a paramagnetic metal ion (e.g. Mn2+) and the corresponding PET isotope (e.g. 52gMn), leads to a “cocktail mixture” where both imaging reporters exhibit the same pharmacokinetics. Paramagnetic [55Mn(CDTA)]2- shows an excellent compromise between thermodynamic stability, kinetic inertness and MR contrast enhancement. Therefore, the aim of this study was to develop new PET/MR tracers by labelling CDTA ligands with paramagnetic manganese and the β+-emitter 52gMn. N.c.a. 52gMn (t1/2: 5.6 d; Eβ+: 575.8 keV (29.6%)) was produced by proton irradiation of a natCr target followed by cation-exchange chromatography. CDTA was radiolabelled with n.c.a. 52gMn2+ in NaOAc buffer (pH 6) at RT. The complex was purified by RP-HPLC and its stability tested in PBS and blood plasma at 37°C. The redox stability was assessed by monitoring the T1 relaxation (20 MHz) in HEPES buffer (pH 7.4). A functionalized CDTA ligand was synthesized in 5 steps. [52gMn(CDTA)]2- was quantitatively formed within 30 min at RT. The complex was stable for at least 6 days in PBS and blood plasma at 37°C and no oxidation occurred within 7 months storage at RT. Labelling CDTA with an isotopic 52g/55Mn2+ mixture led to the corresponding bimodal PET/MR tracer. Furthermore, a functionalized CDTA ligand was synthesized with an overall yield of 18-25%. [52g/55Mn(CDTA)]2-, the first manganese-based bimodal PET/MR tracer prepared, exhibits excellent stability towards decomplexation and oxidation. This makes the functionalized CDTA ligand highly suitable for designing PET/MR tracers with high relaxivity or targeting properties.

  4. Authentically radiolabelled Mn(II) complexes as bimodal PET/MR tracers

    International Nuclear Information System (INIS)

    Vanasschen, Christian; Brandt, Marie; Ermert, Johannes; Neumaier, Bernd; Coenen, Heinz H

    2015-01-01

    The development of small molecule bimodal PET/MR tracers is mainly hampered by the lack of dedicated preparation methods. Authentic radiolabelling of MR contrast agents ensures easy access to such probes: a ligand, chelating a paramagnetic metal ion (e.g. Mn2+) and the corresponding PET isotope (e.g. 52gMn), leads to a “cocktail mixture” where both imaging reporters exhibit the same pharmacokinetics. Paramagnetic [55Mn(CDTA)]2- shows an excellent compromise between thermodynamic stability, kinetic inertness and MR contrast enhancement. Therefore, the aim of this study was to develop new PET/MR tracers by labelling CDTA ligands with paramagnetic manganese and the β+-emitter 52gMn. N.c.a. 52gMn (t1/2: 5.6 d; Eβ+: 575.8 keV (29.6%)) was produced by proton irradiation of a natCr target followed by cation-exchange chromatography. CDTA was radiolabelled with n.c.a. 52gMn2+ in NaOAc buffer (pH 6) at RT. The complex was purified by RP-HPLC and its stability tested in PBS and blood plasma at 37°C. The redox stability was assessed by monitoring the T1 relaxation (20 MHz) in HEPES buffer (pH 7.4). A functionalized CDTA ligand was synthesized in 5 steps. [52gMn(CDTA)]2- was quantitatively formed within 30 min at RT. The complex was stable for at least 6 days in PBS and blood plasma at 37°C and no oxidation occurred within 7 months storage at RT. Labelling CDTA with an isotopic 52g/55Mn2+ mixture led to the corresponding bimodal PET/MR tracer. Furthermore, a functionalized CDTA ligand was synthesized with an overall yield of 18-25%. [52g/55Mn(CDTA)]2-, the first manganese-based bimodal PET/MR tracer prepared, exhibits excellent stability towards decomplexation and oxidation. This makes the functionalized CDTA ligand highly suitable for designing PET/MR tracers with high relaxivity or targeting properties.

  5. Gd-enhanced MR imaging of the herniated lumbar disc: patterns of enhancement

    International Nuclear Information System (INIS)

    Kwag, Hyon Joo; Choi, Hye Young; Kim, Hyae Young; Kim, Yoo Kyung; Kim, Ah Young; Chung, Eun Chul

    1995-01-01

    The purpose of this study is to describe the patterns of enhancement of the herniated lumbar disc with Gd-DTPA enhanced MR imaging. Out of 65 patients, 103 lumbar discs diagnosed to be herniated by MR image were retrospectively analyzed. The MR imaging was performed with 1.5 T MR unit, using T1-and T2-weighted sagittal and axial spin echo techniques. Contrast-enhanced T1 weighted sagittal and axial images were performed after intravenous injection of Gadopentetate-dimeglumine(Magnevist, Shering) (0.1 mmol/kg). Contrast enhancement was seen in 66 cases(64%). Thirteen cases of bulging disc were not enhanced. Twenty-eight cases of protruded disc showed intraannular enchantment in 23 cases, peripheral linear and irregular enhancement in each of one case, and nonenhancement in three cases. Fifty-seven cases of extruded disc showed irregular enhancement in 14 cases, peripheral linear enhancement in 12 cases, peripheral ring enhancement in five cases and intraannular enhancement in five cases. All five cases of sequestered disc showed peripheral ring enhancement. Protruded discs show intraannular enhancement frequently and sequestered discs usually show peripheral ring enhancement. Enhanced MR imaging may be helpful to evaluate the type of herniated lumbar disc and relationship among disc material, nerve root and thecal sac

  6. T-peptide Enhances the Killing Effects of Cisplatinum on Lung Cancer

    Directory of Open Access Journals (Sweden)

    Hongyi ZHANG

    2017-02-01

    Full Text Available Background and objective T peptide is extensively used in anti-tumor treatment. The aims of this study were to investigate whether T peptide enhances cisplatinum efficiency while reducing its side effects and to identify its effective mechanisms. Methods (1 Human macrophage U937 cells were treated with T peptide and/or cisplatinum. The levels of tumor necrosis factor-α (TNF-α and interferon-γ (IFN-γ of each group were detected by enzyme-linked immunosorbent assay (ELISA; (2 Xenograft mouse models of human lung cancer were treated with T peptide and/or cisplatinum once every five days for three times. Tumor volumes were measured during treatment; (3 The percentages of macrophages in the peripheral blood of the xenograft mouse models were measured by FACS. Results (1 Compared with other groups, the level of TNF-α was significantly higher in the human macrophage U937 cells that were treated with T peptide combined with cisplatinum. The levels of IFN-γ were significantly higher in human macrophage U937 cells that were treated with T peptide alone or T peptide combined with cisplatinum; (2 In the xenograft mouse models, T peptide combined with cisplatinum treatment significantly inhibited tumor growth without weight loss compared with the other groups; (3 The percentages of macrophages in the peripheral blood were significantly higher in the xenograft mouse models that were treated with T peptide combined with cisplatinum compared with in the other groups. Conclusion T peptide promotes macrophage proliferation and increases tumor cell killing factors (TNF-α, IFN-γ in vitro. Moreover, T peptide enhances the efficacy of cisplatin and reduces its toxicity in vivo.

  7. Semi-automatic segmentation of myocardium at risk in T2-weighted cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Sjögren Jane

    2012-01-01

    Full Text Available Abstract Background T2-weighted cardiovascular magnetic resonance (CMR has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR, after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD, full width half maximum intensity (FWHM or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. Methods Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. Results MaR was 32.9 ± 10.9% of left ventricular mass (LVM when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p Conclusions There is a good agreement between automatic Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a

  8. Semi-automatic segmentation of myocardium at risk in T2-weighted cardiovascular magnetic resonance.

    Science.gov (United States)

    Sjögren, Jane; Ubachs, Joey F A; Engblom, Henrik; Carlsson, Marcus; Arheden, Håkan; Heiberg, Einar

    2012-01-31

    T2-weighted cardiovascular magnetic resonance (CMR) has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR), after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD), full width half maximum intensity (FWHM) or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. MaR was 32.9 ± 10.9% of left ventricular mass (LVM) when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p Segment MaR, -2.3 ± 4.9%, R = 0.91 (p Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a promising, objective method for standardized MaR quantification in T2

  9. Detection of hyperacute parenchymal hemorrhage of the brain using echo-planar T2{sup *}-weighted and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, M. [Dept. of Radiology, Medizinische Universitaet zu Luebeck (Germany); Mayer, T.E.; Yousry, I.; Brueckmann, H. [Dept. of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany); Hamann, G.F. [Dept. of Neurology, Klinikum Grosshadern, Ludwig-Maximilians-Universitaet, Muenchen (Germany)

    2001-05-01

    We investigated the usefulness of echo-planar imaging (EPI) as well as T2{sup *}-weighted and diffusion-weighted MRI (DWI) to identify hyperacute hemorrhage (within 24 h after ictus) in the brain. Seven patients were examined 3.5 to 24 h after onset of symptoms using a whole-body 1.5-T MR system. Two diffusion-weighted sequences were run to obtain isotropic and anisotropic diffusion images. Apparent diffusion coefficients (ADC) were calculated from the isotropic diffusion images. All DWI images as well as the T2*-weighted EPI images showed the hematomas as either discrete, deeply hypointense homogeneous lesions, or as lesions of mixed signal intensity containing hypointense areas. We conclude that even in the early phase after hemorrhage, sufficient amounts of paramagnetic deoxyhemoglobin are present in intracerebral hemorrhages to cause hypointensity on EPI T2{sup *}-weighted and DWI images; thus, use of ultrafast EPI allows identification of intracerebral hemorrhage. (orig.)

  10. Enhancing pseudocapacitive kinetics of nanostructured MnO2 through anchoring onto biomass-derived porous carbon

    Science.gov (United States)

    Chen, Qiongyu; Chen, Jizhang; Zhou, Yuyang; Song, Chao; Tian, Qinghua; Xu, Junling; Wong, Ching-Ping

    2018-05-01

    The rational construction of heterostructured electrode materials that deliver superior performances to their individual counterparts offers an attractive strategy for supercapacitors. Herein, we anchor low-crystalline nanostructured MnO2 onto soybean stalk-derived carbon matrix through chemical activation and subsequent hydrothermal reaction. The highly porous and conductive matrix can effectively enhance pseudocapacitive kinetics of nanostructured MnO2. Therefore, the obtained nanocomposite exhibits high specific capacitance (384.9 F g-1 at a current density of 0.5 A g-1), great rate capability (185.0 F g-1 at 20 A g-1), and superior cyclability (90.7% capacitance retention after 5000 cycles). Using this nanocomposite as the positive electrode material, an asymmetric supercapacitor (ASC) is assembled, and achieves high specific energy of 34.2 Wh kg-1 and high specific power of 9.58 kW kg-1. The results of this study demonstrate great potential of combining biomass-derived porous carbon with metal oxides.

  11. Ferri-magnetic order in Mn induced spinel Co_3_−_xMn_xO_4 (0.1≤x≤1.0) ceramic compositions

    International Nuclear Information System (INIS)

    Meena, P.L.; Sreenivas, K.; Singh, M.R.; Kumar, Ashok; Singh, S.P.; Kumar, Ravi

    2016-01-01

    We report structural and magnetic properties of spinel Co_3_−_xMn_xO_4 (x=0.11.0) synthesized by solid state reaction technique. Rietveld refinement analysis of X-ray diffraction (XRD) data, revealed the formation of polycrystalline single phase Co_3_−_xMn_xO_4 without any significant structural change in cubic crystal symmetry with Mn substitution, except change in lattice parameter. Temperature dependent magnetization data show changes in magnetic ordering temperature, indicating formation of antiferromagnetic (AFM) and ferrimagnetic (FM) phase at low Mn concentration (x≤0.3) and well-defined FM phase at high Mn concentration (x≥0.5). The isothermal magnetization records established an AFM/FM mixed phase for composition ranging 0.1 0.5. - Highlights: • Synthesis of single phase polycrystalline Co_3_−_xMn_xO_4 ceramic. • Change in magnetic ordering with varying Mn concentration. • The complex spin distribution is contributing to FM ordering with higher Mn.

  12. Hepatocellular carcinoma. Comparison between gadolinium and ironoxide enhanced MR imaging

    International Nuclear Information System (INIS)

    Castoldi, M.C.; Fauda, V.; Scaramuzza, D.; Vergnaghi, D.

    2000-01-01

    Purpose of this work is to compare prospectively dynamic gadolinium (Gd)-enhanced with superparamagnetic iron oxide (SPIO)-enhanced MRI for the detection of hepatocellular carcinoma (HCC). Twenty-five patients with histologically proven HCC and liver cirrhosis (28% of them in B or C Child class) underwent dynamic Gd-enhanced MRI and, a few days later, (mean interval: three days) SPIO-enhanced MRI. Only patients with availability of clinical and imaging follow-up for at least seven months were enrolled in this prospective study. MR images were reviewed by two independent radiologists. The readers scored each lesion for the presence of HCC and assigned confidence levels based on a five-grade scale: 1, definitely or almost definitely absent; 2, possibly present; 3, probably present; 4, definitely present; 5, definitely present with optimal liver/lesion contrast or good liver/lesion contrast and morphological signs (intact capsule, intranodular septa, extracapsular infiltration), useful for locoregional treatment planning. A positive diagnostic value was assessed for scores of 3 or higher. Gd-enhanced and SPIO-enhanced MRI found 44 lesions. Eight of twelve lesions visible with a single contrast agent measured less than 1 cm in diameter. HCC detectability was 75% with Gd-enhanced MRI and 97.7% with SPIO-enhanced MRI. SPIO-enhanced T2-weighted TSE images showed significantly higher diagnostic value than SPIO-enhanced T1-T2*GRE images only in three cases, while nodule morphological characteristics (capsule, septa, different cell differentiation components) were better depicted by TSE images. In thi study the combined use of SPIO-enhanced T2-weighted TSE and T1-T2*-weighted GRE sequences showed higher sensitivity than gadolinium-enhanced GRE dynamic imaging (97.7% versus 75%). These results are at least partly related to our study conditions, that is: 1)MRI was performed with a 1T system, 2) both axial and sagittal SPIO-enhanced imaging were performed with respiratory

  13. Role of improving the physical properties of Sm-123 phase by adding nano-magnetic MnFe{sub 2}O{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Abdeen, W. [Superconductivity and Metallic Glass Lab, Physics Department, Faculty of Science, Alexandria University, Alexandria (Egypt); Physics Department, Physics Department – University College at Al-Gamom, Umm Al-Qura University (Saudi Arabia); El-Tahan, A. [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); Roumié, M. [Accelerator Laboratory, Lebanese Atomic Energy Commission, CNRS, Beirut (Lebanon); Awad, R. [Physics Department, Faculty of Science, Beirut Arab University (BAU), Beirut (Lebanon); Aly, A.I. Abou [Superconductivity and Metallic Glass Lab, Physics Department, Faculty of Science, Alexandria University, Alexandria (Egypt); El-Maghraby, E.M.; Khalaf, A. [Physics Department, Faculty of Science, Damanhur University, Damanhur (Egypt)

    2016-12-01

    Superconducting samples of SmBa{sub 2}Cu{sub 3}O{sub 7−δ} (Sm-123) added with various amounts of nanosized MnFe{sub 2}O{sub 4} addition (0.0−0.20 wt%) were investigated. The investigated samples prepared by the solid-state reaction method. The phase formation and microstructure of these samples were examined using X-ray powder diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), proton induced X-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS). XRD data indicate that the volume fraction of Sm-123 increases as nanosized MnFe{sub 2}O{sub 4} increases up to 0.02 wt%. The elemental distribution and oxygen content were deduced from PIXE and RBS. The oxygen content slightly decreases as MnFe{sub 2}O{sub 4} wt% increases. The superconducting transition temperature (T{sub c}) and critical current density (J{sub c}) of the prepared samples were estimated from electrical resistivity and transport critical current density measurements. It was found that T{sub c} decreases as nanosized MnFe{sub 2}O{sub 4} addition increases, while J{sub c} enhances up to 0.02 wt%. Moreover, the temperature dependence of normal state electrical resistivity was studied in view of the pseudogap opening in order to determine the pseudogap temperature T* as a function of nanosized MnFe{sub 2}O{sub 4} addition. T* increases as nanosized MnFe{sub 2}O{sub 4} increased, indicating the enhancement of the pseudogap formation in HTSCs by adding magnetic impurities. The crossover to fluctuation conductivity near the T{sub c} is discussed. - Highlights: • Nanosized MnFe{sub 2}O{sub 4} most likely does not enter the Sm-123 crystal structure. • Samples present a metallic-like behavior in the normal state at high temperature. • Nanosized MnFe{sub 2}O{sub 4} lead to enhancement the formation of pseudogap in cuprates HTSCs. • The increase in T{sub LD} crossover temperature up to x=0.02 wt% has been observed. • Nanosized MnFe{sub 2}O{sub 4} can

  14. Local Structure of Mn in (La1-xHox)2/3Ca1/3MnO3 Studied by X-ray Absorption Fine Structure

    International Nuclear Information System (INIS)

    Pietnoczka, A.; Bacewicz, R.; Antonowicz, J.; Zalewski, W.; Pekala, M.; Drozd, V.; Fagnard, J.F.; Vanderbemden, P.

    2010-01-01

    Results of X-ray absorption fine structure measurements in manganites (La 1-x Ho x ) 2/3 Ca 1/3 MnO 3 with 0.15 3 is doped with a divalent element such as Ca 2+ , substituting for La 3+ , holes are induced in the filled Mn d orbitals. This leads to a strong ferromagnetic coupling between Mn sites. Ca ions in La 1-x Ca x MnO 3 introduce a distortion of the crystal lattice and mixed valence Mn ions (Mn 3+ and Mn 4+ ). On the other hand, in manganites (La 1-x Ho x ) 2/3 Ca 1/3 MnO 3 the substitution of La for Ho causes a lattice distortion and induces a disorder, which reduces a magnetic interaction. The ferromagnetic transition temperature and conductivity decrease very quickly with increasing x. The magnetic and transport properties of compounds depend on the local atomic structure around Mn ions. The information on the bond lengths and Debye-Waller factor are obtained from the extended X-ray absorption fine structure (EXAFS) data analysis. The charge state of Mn is determined from the position of the absorption edge in X-ray absorption near edge structure (XANES) data. XAFS results are in good agreement with magnetic characteristics of the studied materials. (authors)

  15. Mechanism for enhanced degradation of clofibric acid in aqueous by catalytic ozonation over MnOx/SBA-15

    International Nuclear Information System (INIS)

    Sun, Qiangqiang; Wang, Yu; Li, Laisheng; Bing, Jishuai; Wang, Yingxin; Yan, Huihua

    2015-01-01

    Highlights: • Clofibric acid (CA) is efficiently mineralized by O 3 /MnO x /SBA-15. • Adsorption of CA and its intermediates on MnO x /SBA-15 is proved unimportant. • Initiation of hydroxyl radicals (·OH) is enhanced in O 3 /MnO x /SBA-15. • Uniformly distributed MnO x accounts for the high activity of MnO x /SBA-15. • Degradation routes of CA in ozonation alone and catalytic ozonation are proposed. - Abstract: Comparative experiments were conducted to investigate the catalytic ability of MnO x /SBA-15 for the ozonation of clofibric acid (CA) and its reaction mechanism. Compared with ozonation alone, the degradation of CA was barely enhanced, while the removal of TOC was significantly improved by catalytic ozonation (O 3 /MnO x /SBA-15). Adsorption of CA and its intermediates by MnO x /SBA-15 was proved unimportant in O 3 /MnO x /SBA-15 due to the insignificant adsorption of CA and little TOC variation after ceasing ozone in stopped-flow experiment. The more remarkably inhibition effect of sodium bisulfite (NaHSO 3 ) on the removal of TOC in catalytic ozonation than in ozonation alone elucidated that MnO x /SBA-15 facilitated the generation of hydroxyl radicals (·OH), which was further verified by electron spin-resonance spectroscopy (ESR). Highly dispersed MnO x on SBA-15 were believed to be the main active component in MnO x /SBA-15. Some intermediates were indentified and different degradation routes of CA were proposed in both ozonation alone and catalytic ozonation. The amounts of small molecular carboxylic acids (i.e., formic acid (FA), acetic acid (AA) and oxalic acid (OA)) generated in catalytic ozonation were lower than in ozonation alone, resulting from the generation of more ·OH

  16. Control of luminescence emitted by Cd{sub 1-x}Mn{sub x}S nanocrystals in a glass matrix: x concentration and thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Freitas Neto, Ernesto S; Dantas, Noelio O [Laboratorio de Novos Materiais Isolantes e Semicondutores (LNMIS), Instituto de Fisica, Universidade Federal de Uberlandia, CP 593, CEP 38400-902, Uberlandia, Minas Gerais (Brazil); Barbosa Neto, Newton M [Grupo de Espectroscopia de Materiais (GEM), Instituto de Fisica, Universidade Federal de Uberlandia, CP 593, CEP 38400-902, Uberlandia, Minas Gerais (Brazil); Guedes, Ilde [Departamento de Fisica, Universidade Federal do Ceara, Campus do Pici, CEP 60455-760, Fortaleza, Ceara (Brazil); Chen, Felipe, E-mail: ernestosfn@yahoo.com.br [Centro de Ciencias Naturais e Humanas, Universidade Federal do ABC, CEP 09210-170, Santo Andre, Sao Paulo (Brazil)

    2011-03-11

    Cd{sub 1-x}Mn{sub x}S nanocrystals (NCs) were successfully grown in a glass matrix and investigated by photoluminescence (PL), electron paramagnetic resonance (EPR) and magnetic force microscopy (MFM). We verified that the luminescent properties of these NCs can be controlled both by changing the x concentration and by thermal annealing of the samples. The EPR and PL data showed that the characteristic emission of Mn{sup 2+} ions ({sup 4}T{sub 1}-{sup 6}A{sub 1}) is only observed when this magnetic impurity is substitutionally incorporated in the Cd{sub 1-x}Mn{sub x}S NC core (site S{sub I}). Besides, it was observed that the emission ({sup 4}T{sub 1}-{sup 6}A{sub 1}) suppression, caused by the Mn{sup 2+} ion presence near the surface (site S{sub II}) of the Cd{sub 1-x}Mn{sub x}S NCs, is independent of the host material. The MFM images also confirmed the high quality of the Cd{sub 1-x}Mn{sub x}S NC samples, showing a uniform distribution of total magnetic moments in the nanoparticles.

  17. Enhancement effects and relaxivities of gadolinium-DTPA at 1.5 versus 3 tesla. A phantom study

    International Nuclear Information System (INIS)

    Sasaki, Makoto; Shibata, Eri; Kanbara, Yoshiyuki; Ehara, Shigeru

    2005-01-01

    The purpose of this study was to investigate the difference in enhancement effects and relaxivities of the gadolinium chelate at 1.5 and 3 Tesla (T) and to elucidate the contribution of the high magnetic field to contrast enhancement in spin-echo (SE) and gradient-echo (GRE) images. Phantoms containing water with or without gadopentetate dimeglumine (Gd-DTPA) at different concentrations were scanned using 1.5T and 3T MRI scanners of the same manufacturer and under the same temperature conditions and scanning parameters. Relaxivities of gadolinium, R 1 and R 2 , were estimated from serial T 1 and T 2 values of the phantoms using linear regression. Contrast enhancement ratios in SE and GRE T 1 -weighted images were compared at 1.5 and 3T. The R 1 and R 2 of Gd-DTPA at 1.5 and 3T were 4.79 and 5.14, and 4.50 and 5.09, respectively. Although the relaxivities at 3T were slightly lower than those at 1.5T, the contrast enhancement ratio improved in both SE and GRE images as a result of T 1 prolongation of the water at 3T. The decrease in relaxivities of the Gd-DTPA at 3T appears to be so small that T 1 prolongation of the water improves contrast enhancement, suggesting a potential clinical advantage in administration of Gd-DTPA at high field strength. (author)

  18. Value of T2-weighted MR imaging in differentiating low-fat renal angiomyolipomas from other renal tumors

    International Nuclear Information System (INIS)

    Choi, Hyuck Jae; Kim, Jeong Kon; Kim, Mi-Hyun; Cho, Kyoung-Sik; Ahn, Hanjong; Kim, Choung-Soo

    2011-01-01

    Background: Accurate preoperative diagnosis of fat scanty angiomyolipomas is an important clinical issue. By evaluating the low signal intensity of angiomyolipomas in MR T2-weighted images the diagnostic accuracy can be elevated. Purpose: To retrospectively assess the usefulness of T2-weighted MR imaging for differentiating low-fat angiomyolipomas (AMLs) from other renal tumors. Material and Methods: We retrospectively evaluated 71 patients with surgically proven renal masses (10 AMLs, 57 renal cell carcinomas [RCCs], and four oncocytomas), all of which showed no visible fat as well as gradual enhancement patterns on contrast-enhanced CT. Signal intensity was measured in each renal mass and in the spleen on T2-weighted images, and each signal intensity ratio (SIR) was calculated; SIR values were then compared in the AML and non-AML groups. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of the two parameters for differentiating the two groups. Results: The SIR values (77 ± 24% vs. 162 ± 79%, p = 0.002) were significantly lower in the AML than in the non-AML group. The area under the ROC curve was 0.926 for SIR. The sensitivity and specificity in the diagnosis of AMLs were 90% and 90.2%, using SIR cut-off of 92.5%. Conclusion: Signal intensity measurements on T2-weighted MR images can differentiate AML from non-AML in the kidney

  19. Connectivity strategies to enhance the capacity of weight-bearing networks

    International Nuclear Information System (INIS)

    Janaki, T.M.; Gupte, Neelima

    2003-01-01

    The connectivity properties of a weight-bearing network are exploited to enhance its capacity. We study a 2D network of sites where the weight-bearing capacity of a given site depends on the capacities of the sites connected to it in the layers above. The network consists of clusters, viz., a set of sites connected with each other with the largest such collection of sites being denoted as the maximal cluster. New connections are made between sites in successive layers using two distinct strategies. The key element of our strategies consists of adding as many disjoint clusters as possible to the sites on the trunk T of the maximal cluster. In the first strategy the reconnections start from the last layer upwards and stop when no new sites are added. In the second case, the reconnections start from the top layer and go all the way down to the last layer. The new networks can bear much higher weights than the original networks and have much lower failure rates. The first strategy leads to a greater enhancement of stability, whereas the second leads to a greater enhancement of capacity compared to the original networks. The original network used here is a typical example of the branching hierarchical class. However, the application of strategies similar to ours can yield useful results in other types of networks as well

  20. Crystal-field and Nd-Mn exchange interaction in Nd{sub 2/3}Ca{sub 1/3}MnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Beznosov, A; Fertman, E; Desnenko, V; Loginov, A [B Verkin Institute for Low Temperature Physics and Engineering, NASU, 47 Lenin Ave., 61103 Kharkov (Ukraine); Feher, A; Kajnakova, M, E-mail: fertman@ilt.kharkov.u [Centre of Low Temperature Physics of the Faculty of Science of P.J. Safarik University and IEP SAS, Park Angelinum 9, SK-04154 Kotice (Slovakia)

    2010-01-01

    A study of the low field magnetization and specific heat in magnetic fields up to 9 T of Nd{sub 2/3}Ca{sub 1/3}MnO{sub 3} perovskite in the 2-30 K temperature range has been done. All the specific heat data show broadened Schottky-like anomaly below 20 K. We suppose that such a behavior originates from the Nd magnetic ordering caused by the splitting of the Nd{sup 3+} ions ground-state doublet (GSD) in the effective molecular field H{sub ex} of Mn spin system supplemented by an applied external magnetic field. The zero field GSD splitting is an evidence of a strong exchange coupling between Nd and Mn magnetic subsystems. The Nd-ions magnetic ordering introduces an additional contribution to the ferromagnetic moment producing anomalies of the field-cooled and zero-field-cooled magnetizations of the system below 28 K. The broadened Schottky-like anomalies found are fitted for every field by a set of three Schottky functions. Applied magnetic field extends the anomaly region and shifts it to the higher temperatures. Splitting of the higher crystal field Kramers doublets gives an additional contribution to the heat capacity under magnetic fields. The GSD g-factors g{sub ||} and g{sub p}erpendicular was estimated as 3.4 and 2.2, respectively, and H{sub ex} as 9 T.

  1. Oxygen-enhanced MRI of the lungs. Intraindividual comparison between 1.5 and 3 Tesla

    International Nuclear Information System (INIS)

    Dietrich, Olaf; Thieme, S.F.; Maxien, D.; Nikolaou, K.; Reiser, M.; Schoenberg, S.O.; Fink, C.

    2011-01-01

    Purpose: To assess the feasibility of oxygen-enhanced MRI of the lung at 3 Tesla and to compare signal characteristics with 1.5 Tesla. Materials and Methods: 13 volunteers underwent oxygen-enhanced lung MRI at 1.5 and 3 T with a T 1-weighted single-slice non-selective inversion-recovery single-shot half-Fourier fast-spin-echo sequence with simultaneous respiratory and cardiac triggering in coronal orientation. 40 measurements were acquired during room air breathing and subsequently during oxygen breathing (15 L/min, close-fitting face-mask). The signal-to-noise ratio (SNR) of the lung tissue was determined with a difference image method. The image quality of all acquisitions was visually assessed. The mean values of the oxygen-induced relative signal enhancement and its regional coefficient of variation were calculated and the signal enhancement was displayed as color-coded parameter maps. Oxygen-enhancement maps were visually assessed with respect to the distribution and heterogeneity of the oxygen-related signal enhancement at both field strengths. Results: The mean relative signal enhancement due to oxygen breathing was 13 % (± 5.6 %) at 1.5 T and of 9.0 % (± 8.0 %) at 3 T. The regional coefficient of variation was significantly higher at 3 T. Visual and quantitative assessment of the enhancement maps showed considerably less homogeneous distribution of the signal enhancement at 3 T. The SNR was not significantly different but showed a trend to slightly higher values (increase of about 10 %) at 3 T. Conclusion: Oxygen-enhanced pulmonary MRI is feasible at 3 Tesla. However, signal enhancement is currently more heterogeneous and slightly lower at 3 T. (orig.)

  2. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    Science.gov (United States)

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  3. Artifacts in MRI of the temporomandibular joint caused by dental alloys: a phantom study at 1.5 T

    International Nuclear Information System (INIS)

    Fellner, C.; Erlangen-Nuernberg Univ., Erlangen; Behr, M.; Fellner, F.; Held, P.; Handel, G.; Feuerbach, S.

    1997-01-01

    Purpose: The influence of dental alloys on MRI of the temporomandibular joint was studied using a phantom model for this joint. Methods: At 1,5 T, 15 dental alloys and 14 of their most important components were investigated acquiring sagittal (FOV: 150 mm) and transverse (FOV: 250 mm) T 1 -weighted SE additionally. The artifacts were assessed qualitatively as well as quantitatively, and the samples were subdivided into four artifact categories. Results: Ag, Cu, Ga, In, Ti, Sn, Zn, amalgan, the precious alloys, the Au-Pd and Ag-Pd alloys showed no artifacts (category I). Minimal artifacts below 10 mm on transverse images (category II) were found for Cr, Pd, Pt and for the Ni-Cr alloy. Mn and the remaining non-precious alloys induced artifacts up to 30 mm (category III). Significant artifacts - more than 30 mm - (category IV) were to be more susceptible for artifacts than T 1 -weighted SE and FLASH techniques. Conclusions: In contrast to dental alloys for fixed prosthodontics, Ni-Cr- or 18/8 wires used for orthodontic bands can influence not only the image quality, but also the diagnostic reliability of MRI of the temporomandibular joint. (orig.) [de

  4. Rapid liquid phase sintered Mn doped BiFeO3 ceramics with enhanced polarization and weak magnetization

    Science.gov (United States)

    Kumar, Manoj; Yadav, K. L.

    2007-12-01

    Single-phase BiFe1-xMnxO3 multiferroic ceramics have been synthesized by rapid liquid phase sintering method to study the influence of Mn substitution on their crystal structure, dielectric, magnetic, and ferroelectric behaviors. From XRD analysis it is seen that Mn substitution does not affect the crystal structure of the BiFe1-xMnxO3 system. An enhancement in magnetization was observed for BiFe1-xMnxO3 ceramics. However, the ferooelectric hysteresis loops were not really saturated, we observed a spontaneous polarization of 10.23μC /cm2 under the applied field of 42kV/cm and remanent polarization of 3.99μC/cm2 for x =0.3 ceramic.

  5. Magnetic-entropy change in Mn1.1Fe0.9P0.7As0.3-xGe x

    International Nuclear Information System (INIS)

    Tegus, O.; Fuquan, B.; Dagula, W.; Zhang, L.; Brueck, E.; Si, P.Z.; Boer, F.R. de; Buschow, K.H.J.

    2005-01-01

    We have studied the magnetic properties and magnetic-entropy changes of Mn 1.1 Fe 0.9 P 0.7 As 0.3-x Ge x compounds with x = 0, 0.05, 0.1, 0.15 and 0.3. X-ray diffraction (XRD) study shows all the compounds crystallize in the Fe 2 P-type structure. Magnetic measurements show that the Curie temperature increases from 150 K for Mn 1.1 Fe 0.9 P 0.7 As 0.3 to 380 K for Mn 1.1 Fe 0.9 P 0.7 Ge 0.3 . A field-induced first-order magnetic phase transition is observed above the Curie temperature for the compounds with x up to 0.15. There exists an optimal composition in which the first-order phase transition is the sharpest. The optimal composition for this system is x = 0.1. The maximal magnetic-entropy change derived from the magnetization data is about 40 J/(kg K) for a field change from 0 to 3 T

  6. Enhanced tolerance to stretch-induced performance degradation of stretchable MnO2-based supercapacitors.

    Science.gov (United States)

    Huang, Yan; Huang, Yang; Meng, Wenjun; Zhu, Minshen; Xue, Hongtao; Lee, Chun-Sing; Zhi, Chunyi

    2015-02-04

    The performance of many stretchable electronics, such as energy storage devices and strain sensors, is highly limited by the structural breakdown arising from the stretch imposed. In this article, we focus on a detailed study on materials matching between functional materials and their conductive substrate, as well as enhancement of the tolerance to stretch-induced performance degradation of stretchable supercapacitors, which are essential for the design of a stretchable device. It is revealed that, being widely utilized as the electrode material of the stretchable supercapacitor, metal oxides such as MnO2 nanosheets have serious strain-induced performance degradation due to their rigid structure. In comparison, with conducting polymers like a polypyrrole (PPy) film as the electrochemically active material, the performance of stretchable supercapacitors can be well preserved under strain. Therefore, a smart design is to combine PPy with MnO2 nanosheets to achieve enhanced tolerance to strain-induced performance degradation of MnO2-based supercapacitors, which is realized by fabricating an electrode of PPy-penetrated MnO2 nanosheets. The composite electrodes exhibit a remarkable enhanced tolerance to strain-induced performance degradation with well-preserved performance over 93% under strain. The detailed morphology and electrochemical impedance variations are investigated for the mechanism analyses. Our work presents a systematic investigation on the selection and matching of electrode materials for stretchable supercapacitors to achieve high performance and great tolerance to strain, which may guide the selection of functional materials and their substrate materials for the next-generation of stretchable electronics.

  7. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi [Hyogo Coll. of Medicine, Nishinomiya (Japan)

    2002-03-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  8. A neurotological study of patients with pontine hyperintense lesions on T2 weighted MRI

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Yukimasa, Akiko; Oku, Masaya; Sakagami, Masafumi

    2002-01-01

    Pontine hyperintense lesions seen on T2-weighted MRI were thought to be related to disequilibrium. Some of these lesions have a low signal on T1-weighted imaging, while others have an iso-signal. The purpose of this study was to clarify the relationship between neurological findings and pontine lesions detected by MRI. The subjects were 11 patients (6 males, 5 females; age range: 30 to 83 years [mean: 64.1 years]) with pontine hyperintense lesions identified on T2-weighted MRI. We compared the clinical signs and the MRI findings. Six of the patients had low-intensity areas on T1-weighted images, and the other 5 had iso-intensity areas. Six patients complained of vertigo, and 5 complained of dizziness. Eight complained of positionaly evoked disequilibrium. Positional nystagmus was seen in 4 patients. In 9 patients, abnormalities were found on the ENG test, including the saccadic eye movement test, ETT, and OKP. Numbness on the lips occurred in 2 patients, and cerebellar signs were present in 4. None of the patients had facial paralysis. Disequilibrium originating in the central nervous system was suggested in 10 patients. Clinical examinations revealed similar findings in patients with a low signal on T1-weighted MRI and those with an iso-signal. Our results indicate that pontine lesions identified by T2-weighted MRI cause vertigo or dizziness, and, in most cases, these lesions cause abnormal neurological or neurological abnormalities. (author)

  9. Spin dynamics of the itinerant helimagnet MnSi studied by positive muon spin relaxation

    International Nuclear Information System (INIS)

    Kadono, R.; Matsuzaki, T.; Yamazaki, T.; Kreitzman, S.R.; Brewer, J.H.

    1990-03-01

    The local magnetic fields and spin dynamics of the itinerant helimagnet MnSi(T c ≅ 29.5 K) have been studied experimentally using positive muon spin rotation/relaxation (μ + SR) methods. In the ordered phase (T c ), zero-field μSR was used to measure the hyperfine fields at the muon sites as well as the muon spin-lattice relaxation time T 1 μ . Two magnetically inequivalent interstitial μ + sites were found with hyperfine coupling constants A hf (1) = -3.94 kOe/μ B and A hf (2) = -6.94 kOe/μ B , respectively. In the paramagnetic phase (T > T c ), the muon-nuclear spin double relaxation technique was used to simultaneously but independently determine the spin-lattice relaxation time T 1 Mn of 55 Mn spins and that of positive muons (T 1 μ ) over a wide temperature range (T c 1 Mn and T 1 μ in both phases shows systematic deviations from the predictions of self-consistent renormalization (SCR) theory. (author)

  10. Assessment of image display of contrast enhanced T1W images with fat suppression

    International Nuclear Information System (INIS)

    Miyazaki, Isao; Ishizaki, Keiko; Kobayashi, Kuninori; Katou, Masanobu

    2006-01-01

    The effects of imaging conditions and measures for their improvement were examined with regard to recognition of the effects of contrast on images when T 1 -weighted imaging with selective fat suppression was applied. Luminance at the target region was examined before and after contrast imaging using phantoms assuming pre- and post-imaging conditions. A clinical examination was performed on tumors revealed by breast examination, including those surrounded by mammary gland and by fat tissue. When fat suppression was used and imaging contrast was enhanced, the luminance level of fat tumors with the same structure as the prepared phantoms appeared to be high both before and after contrast imaging, and the effects of contrast were not distinguishable. This observation is attributable to the fact that the imaging conditions before and after contrast imaging were substantially different. To make a comparison between pre- and post-contrast images, it is considered necessary to perform imaging with fixed receiver gain and to apply the same imaging method for pre- and post-contrast images by adjusting post-contrast imaging conditions to those of pre-contrast imaging. (author)

  11. Signal intensity change on unenhanced T1-weighted images in dentate nucleus and globus pallidus after multiple administrations of gadoxetate disodium: an intraindividual comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Conte, Giorgio; Minotti, Marta; De Piano, Francesca [Universita degli Studi di Milano, Postgraduation School in Radiodiagnostics, Milan (Italy); Preda, Lorenzo [Universita degli Studi di Pavia, Department of Clinical-Surgical Diagnostic and Pediatric Sciences, Pavia (Italy); National Center of Oncological Hadrontherapy (CNAO Foundation), Division of Radiology, Pavia (Italy); Cocorocchio, Emilia; Ferrucci, Pier Francesco [European Institute of Oncology, Melanoma and Sarcoma Medical Oncology Division, Milan (Italy); Raimondi, Sara [European Institute of Oncology, Division of Epidemiology and Biostatistics, Milan (Italy); Giannitto, Caterina; Petralia, Giuseppe [European Institute of Oncology, Division of Radiology, Milan (Italy); Bellomi, Massimo [European Institute of Oncology, Division of Radiology, Milan (Italy); Universita degli Studi di Milano, Oncology and Haematology/Oncology Department, Milan (Italy)

    2017-10-15

    To investigate whether there is an increased signal intensity (SI) of dentate nucleus (DN) and globus pallidus (GP) on unenhanced T1-weighted magnetic resonance imaging (MRI), in patients who had undergone multiple administrations of gadoxetate disodium. We retrospectively included stage III melanoma patients, who had been previously enrolled in a trial of adjuvant therapy and who had undergone whole-body contrast-enhanced MRIs with gadoxetate disodium every three months for their follow-up. The SI ratios of DN-to-pons and GP-to-thalamus on unenhanced T1-weighted images were calculated. The difference in SI ratios between the first and the last MRI examinations was assessed and a linear mixed model was performed to detect how SI ratios varied with the number of administrations. Eighteen patients were included in our study. The number of gadoxetate disodium administrations ranged from 2 to 18. Paired t-test did not show any significant difference in DN-to-pons (p=0.21) and GP-to-thalamus (p=0.09) SI ratios by the end of the study. DN-to-pons SI ratio and GP-to-thalamus SI ratio did not significantly increase with increasing the number of administrations (p=0.14 and p=0.06, respectively). Multiple administrations of gadoxetate disodium are not associated with increased SI in DN and GP in the brain. (orig.)

  12. Room temperature magnetic ordering, enhanced magnetization and exchange bias of GdMnO_3 nanoparticles in (GdMnO_3)_0_._7_0(CoFe_2O_4)_0_._3_0

    International Nuclear Information System (INIS)

    Mitra, A.; Mahapatra, A.S.; Mallick, A.; Chakrabarti, P.K.

    2017-01-01

    Nanoparticles of GdMnO_3 (GMO) are prepared by sol-gel method. To enhance the magnetic property and also to obtain the magnetic ordering at room temperature (RT), nanoparticles of GMO are incorporated in the matrix of CoFe_2O_4 (CFO). Desired crystallographic phases of CFO, GMO and GMO-CFO are confirmed by analyzing X-ray diffractrograms (XRD) using Rietveld method. The average size of nanoparticles and their distribution, crystallographic phase, nanocrystallinity etc. are studied by high-resolution transmission electron microscope (HRTEM). Magnetic hysteresis loops (M-H) of GMO-CFO under zero field cooled (ZFC) and field cooled (FC) conditions are observed at different temperatures down to 5 K. Magnetization vs. temperature (M-T) under ZFC and FC conditions are also recorded. Interestingly, exchange bias (EB) is found at low temperature which suggests the encapsulation of the ferromagnetic (FM) nanoparticles of GMO by the ferrimagnetic nanoparticles of CFO below ~100 K. Enhanced magnetization, EB effect and RT magnetic ordering of GMO-CFO would be interesting for both theoretical and experimental investigations. - Highlights: • Nanoparticles of GdMnO_3 are incorporated in the matrix of CoFe_2O_4. • RT magnetic ordering of GMO nanoparticles in GMO-CFO is observed. • Magnetic property of GMO-CFO is highly enhanced compared to GMO. • Exchange bias is found in GMO-CFO at low temperature.

  13. Production possibility of 51Mn via natV(3He,x)51Mn nuclear process for combined positron emission tomography and magnetic resonance imaging studies

    International Nuclear Information System (INIS)

    Szelecsenyi, F.; Kovacs, Z.; Suzuki, K.; Mukai, K.; Japan Steel Works, Yokohama

    2007-01-01

    Complete text of publication follows. It is very difficult to quantify the uptake kinetics and bio-distribution of magneto pharmaceuticals in humans using MRI (Magnetic Resonance Imaging). The well-know PET (Positron Emission Tomography) technique, however, could give a solution to this problem in the case of those MRI contrast agents that are based on manganese as paramagnetic contrast enhancer. Luckily manganese has a proper radioisotope, namely the 51 Mn (T 1/2 = 46.2 min, β + = 97%), which can be easily employed (in the form of 51 Mn-labelled contrast agents) for PET studies. Recently, for the production of this radioisotope proton and deuteron induced nuclear reactions were suggested using natural and enriched Cr targets, respectively. In this work we studied the nat V( 3 He,x) 51 Mn nuclear processes in detail from their respective threshold energies up to 40 MeV. For natural vanadium, the 51 V( 3 He,3n) 51 Mn reaction (natural isotopic composition of 51 V: 99.75%) forms the majority of the required radioisotope. The cross-sections were measured by the conventional stacked-foil method. Two stacks containing 10 and 8 pieces of thin natural V foils were irradiated in external collimated 3 He beams of the AVF-930 isochronous cyclotron of NIRS. Thin copper and titanium foils served as energy degraders. The activations lasted for 1 h with a beam current of 100 nA. The activity of the irradiated samples was measured without chemical separation by using the usual gamma-ray spectroscopy. Since the 51 Mn has a very weak gamma-line at 749 keV (Iγ=0.265%) its activity was measured via decay curve analysis of the annihilation peaks. We also measured the excitation functions of those reactions which form the major radio-contaminants i.e. 52m Mn (T 1/2 =21.1 min, Eγ=1434.068 keV(Iγ=98.3%)) and 52 Mn (T 1/2 = 5.591 d, Eγ=744.223 keV (Iγ=90%), Eγ=935.538 keV (Iγ=94.5%)). The excitation function curve of the nat V( 3 He,x) 51 Mn nuclear process shows one maximum of

  14. Bilateral Pulvinar Signal Intensity Decrease on T2-Weighted Images in Patients with Aspartylglucosaminuria

    International Nuclear Information System (INIS)

    Autti, T.; Loennqvist, T.; Joensuu, R.

    2008-01-01

    Background: Aspartylglucosaminuria (AGU) is an autosomal recessive lysosomal disease caused by deficiency of aspartylglucosaminidase. A thalamic T2 signal intensity decrease is associated with lysosomal diseases. Purpose: To investigate thalamic signal intensity in AGU by performing a retrospective review of brain magnetic resonance (MR) imaging studies of AGU patients. Material and Methods: A total of 25 MR examinations were available for 11 patients aged between 3 and 32 years (four patients underwent bone marrow transplantation). Of these, 13 examinations were performed after bone marrow transplantation. Five patients had from two to six examinations, and six patients had one examination each. In every patient, the diagnosis of AGU was confirmed by blood and urine tests. Eighteen examinations were performed with a 1.0T imager including dual spin-echo T2 and proton density (PD) axial and coronal images, and 10 examinations also included T1-weighted images. Seven examinations were performed with a 1.5T imager including turbo spin-echo axial and coronal T2-weighted images and axial fluid-attenuated inversion recovery (FLAIR) images; three examinations included T1-weighted three-dimensional magnetization-prepared rapid acquisition gradient-echo (3D MPRAGE) images. The signal intensity of the thalamus and pulvinar in every sequence was compared to that of the putamina. Results: In AGU, thalamic alterations were first detectable on T2-weighted images (25 examinations in 11 patients) from the age of 3 years 6 months, showing decreased signal intensity in 21 of 24 examinations. T1-weighted images (13 examinations) showed slightly increased thalamic signal intensity in five out of seven examinations from the age of 7 years, and PD images (19 examinations) showed decreased signal intensity from the age of 16 years (three examinations). The pulvinar showed decreased signal intensity on spin-echo T2-weighted images for 14 of 18 examinations or on FLAIR sequences for seven

  15. An NMR study of Pr0.5Ca0.5Mn1-xGaxO3 (x = 0 and 0.03)

    International Nuclear Information System (INIS)

    Oates, C.J.; Sikora, M.; Zajac, D.; Rybicki, D.; Kapusta, Cz.; Riedi, P.C.; Martin, C.; Yaicle, M.; Maignan, A.

    2004-01-01

    An NMR study of polycrystalline Pr 0. 5Ca 0.5 Mn 1-x Ga x O 3 (x = 0 and 0.03) at 3 K is presented. Zero field spin echo spectra of the Ga doped compound consist of an overlapping 6: 9 ,71 Ga signal at 74 MHz (hyperfine field of 5.3 T), a 55 Mn double exchange line at 375 MHz (35.5 T) and a weak Mn 3+ signal between 400 and 550 MHz. Measurements in an applied field show a step-like increase in the double exchange line intensity, which corresponds to an increase in the amount of the ferromagnetic metallic phase. This coincides with a step-like feature in the bulk magnetization measurements. The effect is similar to that in the previous field dependent 55 Mn NMR measurements of Pr 0.67 Ca 0.33 MnO 3 . At the demagnetized and remanent state, a variation of spin-spin relaxation time T 2 , across the 55 Mn line, due to a Suhl-Nakamura interaction is observed, which suggests that the ferromagnetic metallic double exchange regions, at liquid helium temperatures, are at least 4 nm in size

  16. Application of fast spin-echo T2-weighted imaging for examination of the neurocranium. Comparison with the conventional T2-weighted spin-echo sequence

    International Nuclear Information System (INIS)

    Siewert, C.; Hosten, N.; Felix, R.

    1994-01-01

    T 2 -weighted spin-echo imaging is the standard screening procedure in MR imaging of the neutrocranium. We evaluated fast spin-echo T 2 -weighted imaging (TT 2 ) of the neurocranium in comparison to conventional spin-echo T 2 -weighted imaging (T 2 ). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher than TT 2 than in T 2 (with the exception of grey-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT 2 , Parkinson patients have to be examined by conventional T 2 . If these limitations are taken into account, fast spin-echo T 2 -weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T 2 -weighting achieved in a short acquisition time. (orig.) [de

  17. A prospective comparison study of fast T1 weighted fluid attenuation inversion recovery and T1 weighted turbo spin echo sequence at 3 T in degenerative disease of the cervical spine.

    Science.gov (United States)

    Ganesan, K; Bydder, G M

    2014-09-01

    This study compared T1 fluid attenuation inversion recovery (FLAIR) and T1 turbo spin echo (TSE) sequences for evaluation of cervical spine degenerative disease at 3 T. 72 patients (44 males and 28 females; mean age of 39 years; age range, 27-75 years) with suspected cervical spine degenerative disease were prospectively evaluated. Sagittal images of the spine were obtained using T1 FLAIR and T1 TSE sequences. Two experienced neuroradiologists compared the sequences qualitatively and quantitatively. On qualitative evaluation, cerebrospinal fluid (CSF) nulling and contrast at cord-CSF, disc-CSF and disc-cord interfaces were significantly higher on fast T1 FLAIR images than on T1 TSE images (p degenerative disease, owing to higher cord-CSF, disc-cord and disc-CSF contrast. However, intrinsic cord contrast is low on T1 FLAIR images. T1 FLAIR is more promising and sensitive than T1 TSE for evaluation of degenerative spondyloarthropathy and may provide a foundation for development of MR protocols for early detection of degenerative and neoplastic diseases.

  18. Gd-DTPA-enhanced MR imaging of avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Van de Berg, B.; Malghem, J.; Noel, H.; Maldague, B.

    1990-01-01

    This paper evaluates the interest of Gd-DTPA-enhanced MR imaging in the diagnosis of avascular necrosis (AVN) of the hip. MR imaging of 10 patients with various stages of AVN of the femoral head (14 abnormal hips) was performed (1.5-T Gyroscan). T1-weighted images before and after contrast injection and T2-weighted images were obtained in two planes. MR images were compared with pathologic findings in six femoral head specimens (total hip replacement). In the early stages of AVN (Mitchell classes A and B), a peripheral band of contrast-enhanced tissue appears on T1-weighted images after Gd-DTPA injection, mimicking the double line seen on T2-weighted images. In later stages (class C and D), the sequestrated segments, appearing hypointense on T1-weighted images, usually show a significant signal intensity enhancement after Gd-DTPA injection. The truly avascular areas may be limited to a band of thickened subchondral bone

  19. A preliminary study of the T1rho values of normal knee cartilage using 3 T-MRI

    International Nuclear Information System (INIS)

    Goto, Hajimu; Iwama, Yuki; Fujii, Masahiko; Aoyama, Nobukazu; Kubo, Seiji; Kuroda, Ryosuke; Ohno, Yoshiharu; Sugimura, Kazuro

    2012-01-01

    Introduction: To investigate the degree of the effect of aging and weight-bearing on T1rho values in normal cartilage. Materials and methods: Thirty-two asymptomatic patients were examined using 3.0-T magnetic resonance imaging (MRI) to determine knee cartilage T1rho values and T2 values. The femoral and tibial cartilage was divided into weight-bearing (WB-Rs) and less-weight-bearing (LWB-Rs) regions. Single regression analysis was used to assess the relationship between cartilage T1rho values and age and between T2 values and age. Analysis of variance and post hoc-testing were used to evaluate differences in WB-Rs and LWB-Rs cartilage T1rho values and T2 values. Multiple linear regression modeling was performed to predict cartilage T1rho values. Results: Cartilage T1rho values correlated positively with age for all cartilage regions tested (p < 0.001). There were no significant correlations between cartilage T2 values and age. In both the medial femoral and tibial cartilage, T1rho values were significantly higher in WB-Rs than in LWB-Rs (p < 0.05). There were no significant differences in T2 values between WB-Rs and LWB-Rs. Multiple linear regression analysis showed that both age and weight-bearing were significant predictors of increased medial knee cartilage T1rho values (p < 0.001). Conclusions: Aging and the degree of weight-bearing correlate with the change in cartilage T1rho values. Based on multiple regression modeling, aging may be a more important factor than weight-bearing for cartilage T1rho values.

  20. Bone marrow response in treated patients with Gaucher disease: evaluation by T1-weighted magnetic resonance images and correlation with reduction in liver and spleen volume

    International Nuclear Information System (INIS)

    Terk, M.R.; Dardashti, S.; Liebman, H.A.

    2000-01-01

    Purpose. To determine whether T1-weighted magnetic resonance (MR) images can demonstrate response in the marrow of patients with type 1 Gaucher disease treated with enzyme replacement therapy (ERT) and to determine whether a relationship exists between liver and spleen volume reductions and visible marrow changes.Patients. Forty-two patients with type 1 Gaucher disease were evaluated on at least two occasions. Thirty-two patients received ERT. Of these patients, 15 had a baseline examination prior to the initiation of ERT. The remaining 10 patients did not receive ERT.Design. T1-weighted and gradient recalled echo (GRE) coronal images of the femurs and hips were obtained. Concurrently, liver and spleen volumes were determined using contiguous breath-hold axial gradient-echo images. T1-weighted images of the hips and femurs were evaluated to determine change or lack of change in the yellow marrow.Results. Of the 32 patients receiving ERT, 14 (44%) demonstrated increased signal on T1-weighted images suggesting an increase in the amount of yellow marrow. If only the 15 patients with a baseline examination were considered, the response rate to ERT was 67%. Using Student's t-test a highly significant correlation (P<0.005) was found between marrow response and reduction in liver and spleen volume.Conclusions. Marrow changes in patients receiving ERT can be detected by T1-weighted images. This response correlated with reductions in visceral volumes (P<0.0005). (orig.)

  1. Biopsychosocial Aspects of Weight Management in Type 1 Diabetes: a Review and Next Steps.

    Science.gov (United States)

    Driscoll, Kimberly A; Corbin, Karen D; Maahs, David M; Pratley, Richard; Bishop, Franziska K; Kahkoska, Anna; Hood, Korey K; Mayer-Davis, Elizabeth

    2017-08-01

    This review aims to summarize the type 1 diabetes (T1D) and weight literature with an emphasis on barriers associated with weight management, the unique T1D-specific factors that impact weight loss success, maladaptive and adaptive strategies for weight loss, and interventions to promote weight loss. Weight gain is associated with intensive insulin therapy. Overweight and obese weight status in individuals with T1D is higher than the general population and prevalence is rising. A variety of demographic (e.g., female sex), clinical (e.g., greater insulin needs), environmental (e.g., skipping meals), and psychosocial (e.g., depression, stress) factors are associated with overweight/obese weight status in T1D. Fear of hypoglycemia is a significant barrier to engagement in physical activity. Studies evaluating adaptive weight loss strategies in people with T1D are limited. There is a growing literature highlighting the prevalence and seriousness of overweight and obesity among both youth and adults with T1D. There is an urgent need to develop evidence-based weight management guidelines and interventions that address the unique concerns of individuals with T1D and that concurrently address glycemic control.

  2. Direct observation of the bandwidth-disorder induced variation of charge/orbital ordering structure in RE0.5(Ca1-ySry)1.5MnO4

    International Nuclear Information System (INIS)

    Yu, X Z; Arima, T; Kaneko, Y; He, J P; Mathieu, R; Asaka, T; Hara, T; Kimoto, K; Matsui, Y; Tokura, Y

    2007-01-01

    Changes in the charge/orbital ordering (CO/OO) structure with the bandwidth of the e g band and quenched disorder were investigated in doped manganites RE 0.5 (Ca 1-y Sr y ) 1.5 MnO 4 (RE = Pr,Eu) with a single-layer perovskite structure. A systematic study of the modulation structure associated with the CO/OO phase demonstrated that the long-range commensurate structure changes to a short-range incommensurate structure with increasing Sr content through the enhancement of the bandwidth and quenched disorder in these systems. At the same time, the transition temperature of CO/OO (T CO/OO ) decreases. Changes in structure and T CO/OO with different A-site combinations reveal that the CO/OO phase is strongly suppressed by the widening of the e g band and the stronger quenched disorder in these layered manganites. (fast track communication)

  3. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  4. Evolution of magnetostructural transition and magnetocaloric effect with Al doping in MnCoGe1-xAlx compounds

    KAUST Repository

    Bao, Lifu; Hu, Fengxia; Wu, Rongrong; Wang, Jianping; Chen, Liming; Sun, Jirong; Shen, Baogen; Li, Lain-Jong; Zhang, Bei; Zhang, Xixiang

    2014-01-01

    The effect of Al doping in MnCoGe1-xAlx compounds has been investigated. The substitution of Al for Ge enhances Mn-Mn covalent bonding by shortening the distance of nearest Mn atom layers, and thus stabilizes the hexagonal structure. As a result, first-order magnetostructural transition between ferromagnetic martensite and paramagnetic austenite takes place for the optimized compositions (x = 0.01, 0.02). Accompanied with the magnetostructural transition, large magnetocaloric effect (MCE) is observed. More doping of Al(x = 0.03, 0.04) leads to the separation of magnetic and structural transitions and remarkable reduction of MCE. © 2014 IOP Publishing Ltd.

  5. Evolution of magnetostructural transition and magnetocaloric effect with Al doping in MnCoGe1-xAlx compounds

    KAUST Repository

    Bao, Lifu

    2014-01-03

    The effect of Al doping in MnCoGe1-xAlx compounds has been investigated. The substitution of Al for Ge enhances Mn-Mn covalent bonding by shortening the distance of nearest Mn atom layers, and thus stabilizes the hexagonal structure. As a result, first-order magnetostructural transition between ferromagnetic martensite and paramagnetic austenite takes place for the optimized compositions (x = 0.01, 0.02). Accompanied with the magnetostructural transition, large magnetocaloric effect (MCE) is observed. More doping of Al(x = 0.03, 0.04) leads to the separation of magnetic and structural transitions and remarkable reduction of MCE. © 2014 IOP Publishing Ltd.

  6. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    International Nuclear Information System (INIS)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J.

    1995-01-01

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one

  7. Degeneration of uterine leiomyoma: comparison between Gd-DTPA enhanced MR imaging and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shin, M. J.; Kim, G. W.; No, T. Y.; Ahn, W. H.; Baik, S. K.; Kim, B. G.; Choi, H. Y.; Paik, O. J. [Wallace Memorial Baptist Hospital, Busan (Korea, Republic of)

    1995-05-15

    Gonadotropin-releasing hormone(GnRH) analogues have been used as a conservative or preoperative therapy in the treatment of uterine leiomyoma. Since these drugs, which can induce a low estrogenic state, affect only undegenerative leiomyoma tissue, the aim of the present study was to differentiate degenerative leiomyoma from undegenerative one by Gd-DTPA enhanced magnetic resonance imaging(MRI). There were 40 masses in 24 patients; all were diagnosed by surgical-pathology. With superconductive 0.5T MR circuit, T1-and T2-weighted images and Gd-DTPA T1-weighted images were obtained. Based on a combination of signal intensities of T2-weighted and enhanced T1 weighted image on the same tumor section all the lesions were classified to one of four MRI patterns. Pattern I was a heterogeneous hyperintensity on the T2-weighted images that was enhancement by Gd-DTPA. Pattern II was a high signal intensity on the T2-weighted MR images but no enhancement by Gd-DTPA. Pattern III was a low to intermediate signal intensity on the T2-weighted MR images and enhancement on the Gd-DTPA T1-weighted images. Pattern IV was a low to intermediate signal intensity on the T2-weighted images and no enhancement by Gd-DTPA. Each of these 4 groups of MRI pattern were co-related to the surgical-pathology findings. Pathologically, pattern I corresponded to an edematous leiomyoma in 3 cases and a connective tissue leiomyoma in one case. Pattern II corresponded to three red degeneration, two cystic degeneration and one infected leiomyoma. Pattern III corresponded to eighteen undegenerative leiomyomas, but some of them showed focal connective tissue proliferation. All of twelve cases in pattern IV corresponded to a hyaline degeneration. MRI with Gd-DTPA enhancement may differentiate undegenerative leiomyoma from degenerated one.

  8. Effect of variable thermal conductivity and specific heat capacity on the calculation of the critical metal hydride thickness for Ti1.1CrMn

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rokni, Masoud

    2014-01-01

    model is applied to the metal hydride system, with Ti 1.1 CrMn as the absorbing alloy, to predict the weight fraction of absorbed hydrogen and solid bed temperat ure . Dependencies of thermal conductivity and specific heat capacity upon pressure and hydrogen content respectively , are accounted for...

  9. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    Science.gov (United States)

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  10. Magnetocaloric effect and multifunctional properties of Ni-Mn-based Heusler alloys

    Energy Technology Data Exchange (ETDEWEB)

    Dubenko, Igor, E-mail: igor_doubenko@yahoo.com [Department of Physics, Southern Illinois University, Carbondale, IL 62901 (United States); Samanta, Tapas; Kumar Pathak, Arjun [Department of Physics, Southern Illinois University, Carbondale, IL 62901 (United States); Kazakov, Alexandr; Prudnikov, Valerii [Faculty of Physics, Moscow State University, Vorob' evy Gory, 11999I Moscow (Russian Federation); Stadler, Shane [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Granovsky, Alexander [Faculty of Physics, Moscow State University, Vorob' evy Gory, 11999I Moscow (Russian Federation); IKERBASQUE, The Basque Foundation for Science, 48011 Bilbao (Spain); Departamento de Fisica de Materiales, Facultad de Quimica, Universidad del Pais Vasco, Paseo M. de Lardizabal 3, 20018 Donostia - San Sebastian (Spain); Zhukov, Arcady [IKERBASQUE, The Basque Foundation for Science, 48011 Bilbao (Spain); Departamento de Fisica de Materiales, Facultad de Quimica, Universidad del Pais Vasco, Paseo M. de Lardizabal 3, 20018 Donostia - San Sebastian (Spain); Ali, Naushad [Department of Physics, Southern Illinois University, Carbondale, IL 62901 (United States)

    2012-10-15

    The studies of magnetocaloric properties, phase transitions, and phenomena related to magnetic heterogeneity in the vicinity of the martensitic transition (MT) in Ni-Mn-In and Ni-Mn-Ga off-stoichiometric Heusler alloys are summarized. The crystal structure, magnetocaloric effect (MCE), and magnetotransport properties were studied for the following alloys: Ni{sub 50}Mn{sub 50-x}In{sub x}, Ni{sub 50-x}Co{sub x}Mn{sub 35}In{sub 15}, Ni{sub 50}Mn{sub 35-x}Co{sub x}In{sub 15}, Ni{sub 50}Mn{sub 35}In{sub 14}Z (Z=Al, Ge), Ni{sub 50}Mn{sub 35}In{sub 15-x}Si{sub x}, Ni{sub 50-x}Co{sub x}Mn{sub 25+y}Ga{sub 25-y}, and Ni{sub 50-x}Co{sub x}Mn{sub 32-y}FeyGa{sub 18}. It was found that the magnetic entropy change, {Delta}S, associated with the inverse MCE in the vicinity of the temperature of the magneto-structural transition, TM, persists in a range of (125-5) J/(kg K) for a magnetic field change {Delta}H=5 T. The corresponding temperature varies with composition from 143 to 400 K. The MT in Ni{sub 50}Mn{sub 50-x}In{sub x} (x=13.5) results in a transition between two paramagnetic states. Associated with the paramagnetic austenite-paramagnetic martensite transition {Delta}S=24 J/(kg K) was detected for {Delta}H=5 T at T=350 K. The variation in composition of Ni{sub 2}MnGa can drastically change the magnetic state of the martensitic phase below and in the vicinity of TM. The presence of the martensitic phase with magnetic moment much smaller than that in the austenitic phase above TM leads to the large inverse MCE in the Ni{sub 42}Co{sub 8}Mn{sub 32-y}FeyGa{sub 18} system. The adiabatic change of temperature ({Delta}T{sub ad}) in the vicinity of TC and TM of Ni{sub 50}Mn{sub 35}In{sub 15} and Ni{sub 50}Mn{sub 35}In{sub 14}Z (Z=Al, Ge) was found to be {Delta}T{sub ad}=-2 K and 2 K for {Delta}H=1.8 T, respectively. It was observed that |{Delta}T{sub ad}| Almost-Equal-To 1 K for {Delta}H=1 T for both types of transitions. The results on resistivity, magnetoresistance, Hall

  11. K{sub 1.33}Mn{sub 8}O{sub 16} as an electrocatalyst and a cathode

    Energy Technology Data Exchange (ETDEWEB)

    Jalili, Seifollah, E-mail: sjalili@kntu.ac.ir [Department of Chemistry, K. N. Toosi University of Technology, P.O. Box 15875-4416, Tehran (Iran, Islamic Republic of); Computational Physical Sciences Research Laboratory, School of Nano-Science, Institute for Research in Fundamental Sciences (IPM), P.O. Box 19395-5531, Tehran (Iran, Islamic Republic of); Moharramzadeh Goliaei, Elham [Department of Chemistry, K. N. Toosi University of Technology, P.O. Box 15875-4416, Tehran (Iran, Islamic Republic of); Schofield, Jeremy [Chemical Physics Theory Group, Department of Chemistry, University of Toronto, 80 Saint George Street, Toronto, Ontario, Canada M5S 3H6 (Canada)

    2017-02-15

    Density functional theory (DFT) calculations are carried out to investigate the electronic, magnetic and thermoelectric properties of bulk and nanosheet K{sub 1.33}Mn{sub 8}O{sub 16} materials. The catalytic activity and cathodic performance of bulk and nanosheet structures are examined using the Tran-Blaha modified Becke-Johnson (TB-mBJ) exchange potential. Electronic structure calculations reveal an anti-ferromagnetic ground state, with a TB-mMBJ band gap in bulk K{sub 1.33}Mn{sub 8}O{sub 16} that is in agreement with experimental results. Density of state plots indicate a partial reduction of Mn{sup 4+} ions to Mn{sup 3+}, without any obvious sign of Jahn-Teller distortion. Moreover, use of the O p-band center as a descriptor of catalytic activity suggests that the nanosheet has enhanced catalytic activity compared to the bulk structure. Thermoelectric parameters such as the Seebeck coefficient, electrical conductivity, and thermal conductivity are also calculated, and it is found that the Seebeck coefficients decrease with increasing temperature. High Seebeck coefficients for both spin-up and spin-down states are found in the nanosheet relative to their value in the bulk K{sub 1.33}Mn{sub 8}O{sub 16} structure, whereas the electrical and thermal conductivity are reduced relative to the bulk. In addition, figures of merit values are calculated as a function of the chemical potential and it is found that the nanosheet has a figure of merit of ~1 at room temperature, compared to 0.5 for the bulk material. All results suggest that K{sub 1.33}Mn{sub 8}O{sub 16} nanosheets can be used both as a material in waste heat recovery and as an electrocatalyst in fuel cells and batteries. - Graphical abstract: K{sub 1.33}Mn{sub 8}O{sub 16}: bulk and nanosheet. - Highlights: • Electronic properties of bulk and nanosheet forms of K{sub 1.33}Mn{sub 8}O{sub 16} have been studied. • The K{sub 1.33}Mn{sub 8}O{sub 16} nanosheet is a semiconductor while the bulk is a metal. • K

  12. Accurate late gadolinium enhancement prediction by early T1- based quantitative synthetic mapping

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, Randy van; Harst, Pim van der [University of Groningen, University Medical Centre Groningen, Centre for Medical Imaging, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Department of Cardiology, Groningen (Netherlands); Kuijpers, Dirkjan [University of Groningen, University Medical Centre Groningen, Centre for Medical Imaging, Groningen (Netherlands); Department of Cardiovascular Imaging HMC-Bronovo, The Hague (Netherlands); Kaandorp, Theodorus A.M.; Dijkman, Paul R.M. van [Department of Cardiovascular Imaging HMC-Bronovo, The Hague (Netherlands); Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Centre for Medical Imaging, Groningen (Netherlands); University Medical Center Groningen, Center for Medical Imaging, Groningen (Netherlands)

    2018-02-15

    Early synthetic gadolinium enhancement (ESGE) imaging from post-contrast T1 mapping after adenosine stress-perfusion cardiac magnetic resonance (CMR) was compared to conventional late gadolinium enhancement (LGE) imaging for assessing myocardial scar. Two hundred fourteen consecutive patients suspected of myocardial ischaemia were referred for stress-perfusion CMR. Myocardial infarct volume was quantified on a per-subsegment basis in both synthetic (2-3 min post-gadolinium) and conventional (9 min post-gadolinium) images by two independent observers. Sensitivity, specificity, PPV and NPV were calculated on a per-patient and per-subsegment basis. Both techniques detected 39 gadolinium enhancement areas in 23 patients. The median amount of scar was 2.0 (1.0-3.1) g in ESGE imaging and 2.2 (1.1-3.1) g in LGE imaging (p=0.39). Excellent correlation (r=0.997) and agreement (mean absolute difference: -0.028±0.289 ml) were found between ESGE and LGE images. Sensitivity, specificity, PPV and NPV of ESGE imaging were 96 (78.9-99.9), 99 (97.1-100.0)%, 96 (76.5-99.4) and 99.5 (96.6-99.9) in patient-based and 99 (94.5-100.0), 100 (99.9-100.0)%, 97.0 (91.3-99.0) and 100.0 (99.8-100.0) in subsegment-based analysis. ESGE based on post-contrast T1 mapping after adenosine stress-perfusion CMR imaging shows excellent agreement with conventional LGE imaging for assessing myocardial scar, and can substantially shorten clinical acquisition time. (orig.)

  13. Accurate late gadolinium enhancement prediction by early T1- based quantitative synthetic mapping

    International Nuclear Information System (INIS)

    Dijk, Randy van; Harst, Pim van der; Kuijpers, Dirkjan; Kaandorp, Theodorus A.M.; Dijkman, Paul R.M. van; Vliegenthart, Rozemarijn; Oudkerk, Matthijs

    2018-01-01

    Early synthetic gadolinium enhancement (ESGE) imaging from post-contrast T1 mapping after adenosine stress-perfusion cardiac magnetic resonance (CMR) was compared to conventional late gadolinium enhancement (LGE) imaging for assessing myocardial scar. Two hundred fourteen consecutive patients suspected of myocardial ischaemia were referred for stress-perfusion CMR. Myocardial infarct volume was quantified on a per-subsegment basis in both synthetic (2-3 min post-gadolinium) and conventional (9 min post-gadolinium) images by two independent observers. Sensitivity, specificity, PPV and NPV were calculated on a per-patient and per-subsegment basis. Both techniques detected 39 gadolinium enhancement areas in 23 patients. The median amount of scar was 2.0 (1.0-3.1) g in ESGE imaging and 2.2 (1.1-3.1) g in LGE imaging (p=0.39). Excellent correlation (r=0.997) and agreement (mean absolute difference: -0.028±0.289 ml) were found between ESGE and LGE images. Sensitivity, specificity, PPV and NPV of ESGE imaging were 96 (78.9-99.9), 99 (97.1-100.0)%, 96 (76.5-99.4) and 99.5 (96.6-99.9) in patient-based and 99 (94.5-100.0), 100 (99.9-100.0)%, 97.0 (91.3-99.0) and 100.0 (99.8-100.0) in subsegment-based analysis. ESGE based on post-contrast T1 mapping after adenosine stress-perfusion CMR imaging shows excellent agreement with conventional LGE imaging for assessing myocardial scar, and can substantially shorten clinical acquisition time. (orig.)

  14. Enhanced magnetocaloric effect tuning efficiency in Ni-Mn-Sn alloy ribbons

    Science.gov (United States)

    Quintana-Nedelcos, A.; Sánchez Llamazares, J. L.; Daniel-Perez, G.

    2017-11-01

    The present work was undertaken to investigate the effect of microstructure on the magnetic entropy change of Ni50Mn37Sn13 ribbon alloys. Unchanged sample composition and cell parameter of austenite allowed us to study strictly the correlation between the average grain size and the total magnetic field induced entropy change (ΔST). We found that a size-dependent martensitic transformation tuning results in a wide temperature range tailoring (>40 K) of the magnetic entropy change with a reasonably small variation on the peak value of the total field induced entropy change. The peak values varied from 6.0 J kg-1 K-1 to 7.7 J kg-1 K-1 for applied fields up to 2 T. Different tuning efficiencies obtained by diverse MCE tailoring approaches are compared to highlight the advantages of the herein proposed mechanism.

  15. Neutron diffraction and magnetic study of the Nd0.7Pb0.3Mn1-xFexO3 (0=1) perovskites

    International Nuclear Information System (INIS)

    Blanco, J.J.; Insausti, M.; Gil de Muro, I.; Lezama, L.; Rojo, T.

    2006-01-01

    The effect of Fe doping on the ferromagnetic Nd 0.7 Pb 0.3 Mn 1-x Fe x O 3 (x=0, 0.025, 0.05, 0.075, 0.1) phases has been studied in order to analyze the double-exchange interaction. The structural and magnetic study has been carried out by neutron powder diffraction and susceptibility measurements between 1.7 and 300K. The substitution of Fe at the Mn site results in reductions in both the Curie temperature T c and the magnetic moment per Mn ion without appreciable differences in the crystal structures. All the compounds crystallize in Pnma space group. The thermal evolution of the lattice parameters of the Nd 0.7 Pb 0.3 Mn 1-x Fe x O 3 (x=0.025, 0.05, 0.075) compounds shows discontinuities in volume and lattice parameters close to the magnetic transition temperature. Increasing amounts of Fe 3+ reduces the double exchange interactions and no magnetic contribution for x=0.1 is observed. The magnetic structures of Nd 0.7 Pb 0.3 Mn 1-x Fe x O 3 (x=0, 0.025, 0.05, 0.075) compounds show that the Nd and Mn ions are ferromagnetically ordered

  16. Martensitic transformation and magnetic properties of manganese-rich Ni-Mn-In and Ni-Mn-Sn Heusler alloys

    International Nuclear Information System (INIS)

    Krenke, T.

    2007-01-01

    In the present work, the martensitic transition and the magnetic properties of Manganese rich Ni 50 Mn 50-x Sn x and Ni 50 Mn 50-y In y alloys with 5 at%≤x(y)≤25 at% were investigated. Calorimetry, X-ray and neutron diffraction, magnetization, and strain measurements were performed on polycrystalline samples. It was shown that alloys close to the stoichiometric composition Ni 50 Mn 25 Sn 25 and Ni 50 Mn 25 Sn 25 do not exhibit a structural transition on lowering of the temperature, whereas alloys with x≤15 at% Tin and y≤16 at% Indium transform martensitically. The structural transition temperatures increase linearly with decreasing Tin or Indium content. The crystal structures of the low temperature martensite are modulated as well as unmodulated. Alloys with compositions close to stoichiometry are dominated by ferromagnetic interactions, whereas those close to the binary composition Ni 50 Mn 50 order antiferromagnetically. Ferromagnetic order and structural instability coexist in a narrow composition range between 13 at%≤x≤15 at% and 15 at%≤x≤16 at% for Ni 50 Mn 50-x Sn x and Ni 50 Mn 50-y In y respectively. As a consequence, interesting magnetoelastic effects are observed. The Ni 50 Mn 34 In 16 alloy shows a magnetic field-induced structural transition, whereby application of an external magnetic field in the martensitic state stabilizes the high temperature L2 1 structure. Evidence for this was given by neutron diffraction experiments in external magnetic fields. Moreover, the structural transition temperatures of this alloy show large magnetic field dependencies. By use of calorimetry, M(T), and strain measurements, changes in M s up to -11 K/Tesla are observed. Such large values have, until now, not been observed in Heusler alloys. Since during transformation the volume changes reversibly, magnetic field-induced strains of about 0.12 % appear. Additionally, the alloys Ni 50 Mn 35 Sn 15 , Ni 50 Mn 37 Sn 13 , Ni 50 Mn 34 In 16 , Ni 51.5 Mn 33 In

  17. Kondo effect and spin-glass freezing of the magnetic impurities Cr, Mn, and Fe in superconducting palladium hydride

    International Nuclear Information System (INIS)

    van Dongen, J.C.M.; van Dijk, D.; Mydosh, J.A.

    1981-01-01

    Through low-field ac susceptibility measurements we have determined the depression of the superconducting transition temperature T/sub c/ in palladium hydride (T/sub c/0 = 9.3 K) as a function of impurity concentration x for Cr, Mn, and Fe. For Cr and Fe similar values for the initial T/sub c/ depression were found, i.e., -150 K/at. % Cr and -145 K/at. % Fe. From resistivity experiments we are able to estimate the Kondo temperatures T/sub K/, i.e., T/sub K/approx. =10 K for Cr and T/sub K/approx. =5 K for Fe. Since i.e., T/sub K/approx. =10 K for Cr and T/sub K/approx. =5 K for Fe. Since systems exhibits an enhanced pair breaking as described by the theory of Mueller-Hartmann and Zittartz. In contrast, for Mn the initial T/sub c/ depression is -21 K/at. % and T/sub K/<< T/sub c/0, as can be concluded from our resistivity measurements. This means that Mn in PdH exhibits a temperature-independent pair breaking of the Abrikosov and Gor'kov type. However, at larger Mnx values a shoulder appears in T/sub c/(x). We interpret this enhanced superconductivity, according to the theory of Soukoulis and Grest, as being due to the onset of time correlations and short-range antiferromagnetic ordering between the Mn moments. These interaction effects are a precursor to the spin-glass freezing at a lower temperature T/sub f/. Our results suggest a favorable coexistance of superconductivity with the spin-glass state

  18. Synthesis of an S T = 7 [Mn 3 ] Mixed-Valence Complex Based on 1,3-Propanediol Ligand Derivatives and Its One-Dimensional Assemblies

    KAUST Repository

    Huang, Jian

    2013-10-07

    Controlled organization of high-spin complexes and single-molecule magnets is a great challenge in molecular magnetism in order to study the effect of the intercomplex magnetic interactions on the intrinsic properties of a given magnetic object. In this work, a new ST = 7 trinuclear mixed-valence Mn complex, [MnIIIMnII 2(LA) 2(Br)4(CH3OH)6] ·Br· (CH3OH)1.5·(H2O)0.5 (1), is reported using a pyridinium-functionalized 1,3-propanediol ligand (H 2LABr = 1-(3-bromo-2,2-bis(hydroxymethyl)propyl)pyridinium bromide). Using azido anions as bridging ligands and different pyridinium-functionalized 1,3-propanediol ligands (H2LBBr = 1-(3-bromo-2,2-bis(hydroxymethyl)propyl)-4-picolinium bromide; H 2LCBr = 1-(3-bromo-2,2-bis(hydroxymethyl)propyl)-3,5- lutidinium bromide), the linear [MnIIIMnII 2L2X4]+ building block has been assembled into one-dimensional coordination networks: [MnIIIMn II 2(LA)2(Br)4(CH 3OH)4(N3)]·((C2H 5)2O)1.25 (2∞), [MnIIIMn II 2(LB)2(Br)4(C 2H5OH)(CH3OH)(H2O) 2(N3)]·(H2O)0.25 (3∞), and [MnIIIMnII 2(LC) 2(Cl)3.8(Br)0.2(C2H 5OH)3(CH3OH)(N3)] (4∞). The syntheses, characterization, crystal structures, and magnetic properties of these new [Mn3]-based materials are reported. © 2013 American Chemical Society.

  19. Temperature dependent changes of the Mn 3d and 4p bands near $T_{c}$ in Colossal Magnetoresistance systems : a XANES study of $La_{1-x}Ca_{x}MnO_{3}$

    NARCIS (Netherlands)

    Bridges, F; Booth, C. H.; Kwei, G. H.; Neumeier, J. J.; Sawatzky, G. A.

    2000-01-01

    Abstract: We report high-resolution X-ray Absorption Near Edge Structure (XANES)measurements at the Mn K-edge as a function of temperature, forLa$_{1-x}$Ca$_x$MnO$_3$ samples, with a focus mainly on the pre-edge region.Small peaks labeled A$_1$-A$_3$ are observed which corresponds to

  20. A hierarchical nanostructure consisting of amorphous MnO{sub 2}, Mn{sub 3}O{sub 4} nanocrystallites, and single-crystalline MnOOH nanowires for supercapacitors

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Chi-Chang; Hung, Ching-Yun [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu 30013 (China); Chang, Kuo-Hsin [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu 30013 (China); Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China); Yang, Yi-Lin [Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China)

    2011-01-15

    In this communication, a porous hierarchical nanostructure consisting of amorphous MnO{sub 2} (a-MnO{sub 2}), Mn{sub 3}O{sub 4} nanocrystals, and single-crystalline MnOOH nanowires is designed for the supercapacitor application, which is prepared by a simple two-step electrochemical deposition process. Because of the gradual co-transformation of Mn{sub 3}O{sub 4} nanocrystals and a-MnO{sub 2} nanorods into an amorphous manganese oxide, the cycle stability of a-MnO{sub 2} is obviously enhanced by adding Mn{sub 3}O{sub 4}. This unique ternary oxide nanocomposite with 100-cycle CV activation exhibits excellent capacitive performances, i.e., excellent reversibility, high specific capacitances (470 F g{sup -1} in CaCl{sub 2}), high power property, and outstanding cycle stability. The highly porous microstructures of this composite before and after the 10,000-cycle CV test are examined by means of scanning electron microscopy (SEM) and transmission electron microscopy (TEM). (author)

  1. Colossal magnetoresistance of bulk Ag-doped Nd{sub 0.7}Sr{sub 0.3}MnO{sub 3} two-phase composites

    Energy Technology Data Exchange (ETDEWEB)

    Cui Xugao [National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, Nanjing 210093 (China); Hu Xiukun [National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, Nanjing 210093 (China); Xia Hongxu [National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, Nanjing 210093 (China); Yu Jiangying [National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, Nanjing 210093 (China); Zhang Shiyuan [National Laboratory of Solid State Microstructures, Department of Physics, Nanjing University, Nanjing 210093 (China)]. E-mail: zsy@netra.nju.edu.cn

    2005-05-17

    We have prepared a series of bulk polycrystalline manganites with the nominal compositions, Nd{sub 0.7}Sr{sub 0.3}MnO{sub 3}-Ag {sub x} (x is the molar fraction) with x = 0.1, 0.2, 0.3, 0.4, 0.5 by conventional solid-state reaction. The X-ray diffraction patterns show that the sample Nd{sub 0.7}Sr{sub 0.3}MnO{sub 3} (x = 0) is a single-phase compound with the pseudocubic perovskite structure, while the Ag-doped samples are two-phase composites consisting of a ferromagnetic perovskite phase and a nonmagnetic Ag metal phase. For all the samples, the Curie temperature, T {sub C}, remains nearly the same (228 {+-} 2 K), but the maximum magnetoresistance in a magnetic field of 1 T at 222 K is enhanced strongly due to the addition of Ag, namely, from 45% for the Nd{sub 0.7}Sr{sub 0.3}MnO{sub 3} sample to 188, 277, 142, 158 and 151% for the Nd{sub 0.7}Sr{sub 0.3}MnO{sub 3}-Ag {sub x} samples with x = 0.1, 0.2, 0.3, 0.4, and 0.5, respectively. This magnetoresistance-enhancement phenomenon can be attributed to the spin-dependent scattering of the spin-polarized electrons at the interfaces between the perovskite grains and the Ag granules.

  2. Magnetic resonance enteroclysis in patients with Crohn's disease: fat saturated T2-weighted sequences for evaluation of inflammatory activity.

    Science.gov (United States)

    Grieser, Christian; Denecke, Timm; Steffen, Ingo G; Werner, Scarlett; Kröncke, Thomas; Guckelberger, Olaf; Pape, Ulrich-Frank; Meier, Johannes; Thiel, Regina; Kivelitz, Dietmar; Sturm, Andreas; Hamm, Bernd; Röttgen, Rainer

    2012-04-01

    To evaluate fat saturated (fs) T2-weighted (w) fast relaxation fast spin echo (FRFSE)-sequences compared to the standard protocol with contrast agent for the evaluation of inflammatory activity in patients with Crohn's Disease (CD). Fourty-eight patients (male, 17; female, 33; mean age, 37 years) with suspicion of inflammatory activity in proven CD who underwent MR enteroclysis (MRE) at 1.5T (GE Healthcare) were retrospectively included. Two blinded radiologists analyzed MRE images for presence and extent of CD lesions and degree of local inflammation for fsT2-w FRFSE and contrast enhanced T1-w images (T2-activity; T1-activity; score, 1-4) in consensus. Furthermore, mural signal intensity (SI) ratios (T2-ratio; T1-ratio) were recorded. Patient based MRE findings were correlated with endoscopic (45 patients), surgical (6 patients), histopathological, and clinical data (CDAI) as a surrogate reference standard. In total, 24 of 48 eligible patients presented with acute inflammatory activity with 123 affected bowel segments. ROC analysis of the total inflammatory score presented an AUC of 0.93 (pT2-activity (T1-activity, AUC 0.63; p=0.019). ROC analysis revealed an AUC of 0.76 (pT2-ratio (T1-ratio, AUC 0.51; p=0.93). General linear regression model revealed T2-activity (p=0.001) and age (p=0.024) as predictive factors of acute bowel inflammation. T2-w FRFSE-sequences can depict CD lesions and help to assess the inflammation activity, even with improved accuracy as compared to contrast-enhanced T1-w sequences. Copyright © 2011 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  3. Dopant driven tunability of dielectric relaxation in MxCo(1-x)Fe2O4 (M: Zn2+, Mn2+, Ni2+) nano-ferrites

    Science.gov (United States)

    Datt, Gopal; Abhyankar, A. C.

    2017-07-01

    Nano-ferrites with tunable dielectric and magnetic properties are highly desirable in modern electronics industries. This work reports the effect of ferromagnetic (Ni), anti-ferromagnetic (Mn), and non-magnetic (Zn) substitution on cobalt-ferrites' dielectric and magnetic properties. The Rietveld analysis of XRD data and the Raman spectroscopic study reveals that all the samples are crystallized in the Fd-3m space group. The T2g Raman mode was observed to split into branches, which is due to the presence of different cations (with different vibrational frequencies) at crystallographic A and B-sites. The magnetization study shows that the MnCoFe2O4 sample has the highest saturation magnetization of 87 emu/g, which is attributed to the presence of Mn2+ cations at the B-site with a magnetic moment of 5 μB. The dielectric permittivity of these nanoparticles (NPs) obeys the modified Debye model, which is further supported by Cole-Cole plots. The dielectric constant of MnCoFe2O4 ferrite is found to be one order higher than that of the other two ferrites. The increased bond length of the Mn2+-O2- bond along with the enhanced d-d electron transition between Mn 2 +/Co 2 +⇋Fe 3 + cations at the B-site are found to be the main contributing factors for the enhanced dielectric constant of MnCoFe2O4 ferrite. We find evidence of variable-range hopping of localized polarons in these ferrite NPs. The activation energy, hopping range, and density of states N (" separators="|EF ), of these polarons were calculated using Motts' 1/4th law. The estimated activation energies of these polarons at 300 K were found to be 288 meV, 426 meV, and 410 meV, respectively, for the MnCoFe2O4, NiCoFe2O4, and ZnCoFe2O4 ferrite NPs, while the hopping range of these polarons were found to be 27.14 Å, 11.66 Å, and 8.17 Å, respectively. Observation of a low dielectric loss of ˜0.04, in the frequency range of 0.1-1 MHz, in these NPs makes them potential candidates for energy harvesting devices in

  4. Cytomegalovirus vector expressing RAE-1γ induces enhanced anti-tumor capacity of murine CD8+ T cells.

    Science.gov (United States)

    Tršan, Tihana; Vuković, Kristina; Filipović, Petra; Brizić, Ana Lesac; Lemmermann, Niels A W; Schober, Kilian; Busch, Dirk H; Britt, William J; Messerle, Martin; Krmpotić, Astrid; Jonjić, Stipan

    2017-08-01

    Designing CD8 + T-cell vaccines, which would provide protection against tumors is still considered a great challenge in immunotherapy. Here we show the robust potential of cytomegalovirus (CMV) vector expressing the NKG2D ligand RAE-1γ as CD8 + T cell-based vaccine against malignant tumors. Immunization with the CMV vector expressing RAE-1γ, delayed tumor growth or even provided complete protection against tumor challenge in both prophylactic and therapeutic settings. Moreover, a potent tumor control in mice vaccinated with this vector can be further enhanced by blocking the immune checkpoints TIGIT and PD-1. CMV vector expressing RAE-1γ potentiated expansion of KLRG1 + CD8 + T cells with enhanced effector properties. This vaccination was even more efficient in neonatal mice, resulting in the expansion and long-term maintenance of epitope-specific CD8 + T cells conferring robust resistance against tumor challenge. Our data show that immunomodulation of CD8 + T-cell responses promoted by herpesvirus expressing a ligand for NKG2D receptor can provide a powerful platform for the prevention and treatment of CD8 + T-cell sensitive tumors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Size-dependent structure and magnetic properties of DyMnO{sub 3} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Xuan; Shi, Lei, E-mail: shil@ustc.edu.cn; Zhou, Shiming; Zhao, Jiyin; Guo, Yuqiao; Wang, Cailin [Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2014-09-14

    The structure and magnetic properties of orthorhombic DyMnO{sub 3} nanoparticles with different particle sizes are investigated in this paper. With decreasing particle size, all the lattice parameters a, b, and c gradually decrease, whereas the orthorhombic distortion increases. Magnetic measurements reveal that the antiferromagnetic interaction of Mn ions is weakened due to the decrease in Mn-O-Mn bond angle. Above a critical field H*, DyMnO{sub 3} undergoes a field-induced metamagnetic transition at 4 K, which is related to the spin reversal of Dy moments. The critical field H* increases monotonically with size reduction, indicating an enhancement of the antiferromagnetic interaction of Dy ions due to the decreased distance between rare earth ions. The magnetization at 4 K and 5 T, i.e., M(4 K, 5 T) shows a non-monotonic variation with particle size d, i.e., M(4 K, 5 T) initially increases with size reduction but decreases again for d < 68 nm. A modified core-shell model, in which the ferromagnetic ordering (Dy magnetic structure) and antiferromagnetic ordering (Mn magnetic structure) coexist in the core, is proposed to explain this behavior.

  6. Statistical parametric mapping for effects of verapamil on olfactory connections of rat brain in vivo using manganese-enhanced MR imaging

    International Nuclear Information System (INIS)

    Soma, Tsutomu; Kurakawa, Masami; Koto, Daichi

    2011-01-01

    We investigated the effect of verapamil on the transport of manganese in the olfactory connections of rat brains in vivo using statistical parametric mapping and manganese-enhanced magnetic resonance (MR) imaging. We divided 12 7-week-old male Sprague-Dawley rats into 2 groups of six and injected 10 μL of saline into the right nasal cavities of the first group and 10 μL of verapamil (2.5 mg/mL) into the other group. Twenty minutes after the initial injection, we injected 10 μL of MnCl 2 (1 mol/L) into the right nasal cavities of both groups. We obtained serial T 1 -weighted MR images before administering the verapamil or saline and at 0.5, one, 24, 48, and 72 hours and 7 days after administering the MnCl 2 , spatially normalized the MR images on the rat brain atlas, and analyzed the data using voxel-based statistical comparison. Statistical parametric maps demonstrated the transport of manganese. Manganese ions created significant enhancement (t-score=36.6) 24 hours after MnCl 2 administration in the group administered saline but not at the same time point in the group receiving verapamil. The extent of significantly enhanced regions peaked at 72 hours in both groups and both sides of the brain. The peak of extent in the right side brain in the group injected with saline was 70.2 mm 3 and in the group with verapamil, 92.4 mm 3 . The extents in the left side were 64.0 mm 3 for the group with saline and 53.2 mm 3 for the group with verapamil. We applied statistical parametric mapping using manganese-enhanced MR imaging to demonstrate in vivo the transport of manganese in the olfactory connections of rat brains with and without verapamil and found that verapamil did affect this transport. (author)

  7. Suppression of the long-range magnetic order in Pb{sub 3}(Mn{sub 1−x}Fe{sub x}){sub 7}O{sub 15} upon substitution of Fe for Mn

    Energy Technology Data Exchange (ETDEWEB)

    Volkov, N.V. [Kirensky Institute of Physics, Russian Academy of Sciences, Siberian Branch, Krasnoyarsk 660036 (Russian Federation); Eremin, E.V., E-mail: eev@iph.krasn.ru [Kirensky Institute of Physics, Russian Academy of Sciences, Siberian Branch, Krasnoyarsk 660036 (Russian Federation); Bayukov, O.A.; Sablina, K.A. [Kirensky Institute of Physics, Russian Academy of Sciences, Siberian Branch, Krasnoyarsk 660036 (Russian Federation); Solov’ev, L.A. [Institute of Chemistry and Chemical Technology, Russian Academy of Sciences, Siberian Branch, Krasnoyarsk 660049 (Russian Federation); Velikanov, D.A.; Mikhashenok, N.V.; Osetrov, E.I. [Kirensky Institute of Physics, Russian Academy of Sciences, Siberian Branch, Krasnoyarsk 660036 (Russian Federation); Schefer, J.; Keller, L. [Laboratory for Neutron Scattering, ETH Zurich and Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Boehm, M. [Institut Laue-Langevin, 6 rue Jules Horowitz, BP 156, 38042 Grenoble, Cedex 9 (France)

    2013-09-15

    Structure and magnetic properties of Pb{sub 3}(Mn{sub 1−x}Fe{sub x}){sub 7}O{sub 15} single crystals with x=0–0.2 grown by spontaneous crystallization from solution in melt have been investigated. All the crystals belong to the hexagonal space group P6{sub 3}/mcm. The magnetic properties appeared to be strongly dependent on the iron doping level. At small (x=0.05) dopant concentrations, the value of magnetization and Neel temperature T{sub N} decrease insignificantly (T{sub N}=70 K). With increasing x, the three-dimensional magnetic ordering does not occur and temperature dependences of magnetization at x≥0.1 exhibit spin-glass-like features in the low-temperature region. - Highlights: • In the first time the single crystals of Pb{sub 3}(Mn{sub 1−x}Fe{sub x}){sub 7}O{sub 15} were grown. • The valence and locations of iron ions in crystal were determined. • Suppression of the long-range magnetic order in Pb{sub 3}(Mn{sub 1−x}Fe{sub x}){sub 7}O{sub 15} was discovered.

  8. Enhancing the blocking temperature in single-molecule magnets by incorporating 3d-5d exchange interactions

    DEFF Research Database (Denmark)

    Pedersen, Kasper Søndergaard; Schau-Magnussen, Magnus; Bendix, Jesper

    2010-01-01

    We report the first single-molecule magnet (SMM) to incorporate the [Os(CN)(6)](3-) moiety. The compound (1) has a trimeric, cyanide-bridged Mn(III)-Os(III)-Mn(III) skeleton in which Mn(III) designates a [Mn(5-Brsalen)(MeOH)](+) unit (5-Brsalen=N,N'-ethylenebis(5-bromosalicylideneiminato)). X......-ray crystallographic experiments reveal that 1 is isostructural with the Mn(III)-Fe(III)-Mn(III) analogue (2). Both compounds exhibit a frequency-dependent out-of-phase ¿''(T) alternating current (ac) susceptibility signal that is suggestive of SMM behaviour. From the Arrhenius expression, the effective barrier for 1...... for the design of a new generation of SMMs with enhanced SMM properties....

  9. Mn55 NMR investigation of the correlation between antiferromagnetism and ferroelectricity in TbMn2O5

    Science.gov (United States)

    Baek, S.-H.; Reyes, A. P.; Hoch, M. J. R.; Moulton, W. G.; Kuhns, P. L.; Harter, A. G.; Hur, N.; Cheong, S.-W.

    2006-10-01

    The correlation between antiferromagnetism and ferroelectricity in magnetoelectric multiferroic TbMn2O5 has been investigated by zero-field Mn55 NMR. Antiferromagnetic transition near 40K is found to be first order. When an external field up to 7T is applied along the easy a axis, a dramatic change in the signal intensity is observed which is hysteretic in nature. Such effects are absent for H along the b and c axes. The observed field-induced signal enhancement is attributed to antiferromagnetic domain walls which are strongly coupled to ferroelectric domain walls. Experimental data suggest that this may be related to the field-induced ferromagnetic ordering of the Tb ion.

  10. Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Tesla

    International Nuclear Information System (INIS)

    Stehling, C.; Niederstadt, T.; Kraemer, S.; Kugel, H.; Schwindt, W.; Heindel, W.; Bachmann, R.

    2005-01-01

    Purpose: The increased T1 relaxation times at 3.0 Tesla lead to a reduced T1 contrast, requiring adaptation of imaging protocols for high magnetic fields. This prospective study assesses the performance of three techniques for T1-weighted imaging (T1w) at 3.0 T with regard to gray-white differentiation and contrast-to-noise-ratio (CNR). Materials and Methods: Thirty-one patients were examined at a 3.0 T system with axial T1 w inversion recovery (IR), spin-echo (SE) and gradient echo (GE) sequences and after contrast enhancement (CE) with CE-SE and CE-GE sequences. For qualitative analysis, the images were ranked with regard to artifacts, gray-white differentiation, image noise and overall diagnostic quality. For quantitative analysis, the CNR was calculated, and cortex and basal ganglia were compared with the white matter. Results: In the qualitative analysis, IR was judged superior to SE and GE for gray-white differentiation, image noise and overall diagnostic quality, but inferior to the GE sequence with regard to artifacts. CE-GE proved superior to CE-SE in all categories. In the quantitative analysis, CNR of the based ganglia was highest for IR, followed by GE and SE. For the CNR of the cortex, no significant difference was found between IR (16.9) and GE (15.4) but both were superior to the SE (9.4). The CNR of the cortex was significantly higher for CE-GE compared to CE-SE (12.7 vs. 7.6, p<0.001), but the CNR of the basal ganglia was not significantly different. Conclusion: For unenhanced T1w imaging at 3.0 T, the IR technique is, despite increased artifacts, the method of choice due to its superior gray-white differentiation and best overall image quality. For CE-studies, GE sequences are recommended. For cerebral imaging, SE sequences give unsatisfactory results at 3.0 T. (orig.)

  11. Age hardening in die-cast Mg–Al–RE alloys due to minor Mn additions

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, S.M., E-mail: suming.zhu@rmit.edu.au [School Engineering, RMIT University, Carlton, Victoria 3053 (Australia); Department of Materials Science and Engineering, Monash University, Victoria 3800 (Australia); Abbott, T.B. [School Engineering, RMIT University, Carlton, Victoria 3053 (Australia); Department of Materials Science and Engineering, Monash University, Victoria 3800 (Australia); Magontec Limited, Sydney, New South Wales 2000 (Australia); Gibson, M.A. [School Engineering, RMIT University, Carlton, Victoria 3053 (Australia); Department of Materials Science and Engineering, Monash University, Victoria 3800 (Australia); CSIRO Manufacturing Flagship, Clayton, Victoria 3168 (Australia); Nie, J.F. [Department of Materials Science and Engineering, Monash University, Victoria 3800 (Australia); Easton, M.A. [School Engineering, RMIT University, Carlton, Victoria 3053 (Australia)

    2016-02-22

    Die-cast Mg–Al–rare earth (RE) alloys are normally used in the as-cast condition without the application of heat treatment because it is a common perception that heat treatment will not provide benefit to these alloys. This paper reports, for the first time, that enhanced age hardenability can be achieved in die-cast Mg–Al–RE alloys with minor Mn additions. For example, the yield strength of Mg–4 wt%Al–3 wt%La alloy with 0.32 wt% Mn is increased by ∼34 MPa (∼26%) after ageing at 200 °C for 32 h (T5). The enhanced age hardenability is associated with the precipitation of nanoscale Al–Mn particles during ageing.

  12. Synthesis, Magnetization, and Electrical Transport Properties of Mn3Zn0.9Cu0.1N

    Directory of Open Access Journals (Sweden)

    Y. Yin

    2013-01-01

    Full Text Available We synthesized Mn3Zn0.9Cu0.1N by solid state reaction, and magnetic as well as electrical transport properties were investigated. It is found that Mn3Zn0.9Cu0.1N exhibits a first-order antiferromagnetism (AFM to paramagnetic (PM transition with the Néel temperature TN ~163 K, and substitution of Cu for Zn would favor ferromagnetism (FM state and weaken AFM ground state, leading to a convex curvature character of M(T curve. With high external fields 10 kOe–50 kOe, magnetic transition remains a robust AFM-PM feature while FM phase is completely suppressed. Thermal hysteresis of M(T under 500 Oe is also suppressed when the magnetic field exceeds 10 kOe. Mn3Zn0.9Cu0.1N exhibits a good metallic behavior except for a slope change around TN, which is closely related to AFM-PM magnetic transition. Compared with the first differential of resistivity with respect to temperature for (dρ/dTMn3ZnN in transition temperature range, the absolute value of (dρ/dTMn3Zn0.9Cu0.1N is much lower which is close to zero.

  13. Comparison of axial T1 spin-echo and T1 fat-saturation magnetic resonance imaging techniques in the diagnosis of chondromalacia patellae.

    Science.gov (United States)

    Vanarthos, W J; Pope, T L; Monu, J U

    1994-12-01

    To test the diagnostic value of T1 spin-echo and T1 fat-saturated magnetic resonance images (MRIs), we reviewed axial T1-weighted images with and without fat saturation in 20 patients with clinically suspected chondromalacia of the patella. All scans were obtained on 1.5-MR units. The scans were randomly ordered and reviewed independently at different times by two radiologists without knowledge of the arthroscopy results. The sensitivity of the individual techniques for detecting grade 3 or 4 chondromalacia patellae was 92% for fat-saturated axial T1-weighted images alone, and 67% for axial T1-weighted images without fat saturation. The sensitivity of the combined techniques was 100% for grades 3 and 4 and 90% for all grades (0 to 4). Chondromalacia patellae is diagnosed more accurately by using T1 fat saturation than by using T1 spin-echo images. With a combination of the two techniques, accuracy is 90% to 100%.

  14. Enhancement of magnetoresistance and ferromagnetic coupling in the complex perovskites CaCu{sub 3}(Mn{sub 4−x}Al{sub x})O{sub 12} (x = 0, 0.2, 0.4, and 0.6): A neutron diffraction study

    Energy Technology Data Exchange (ETDEWEB)

    Ben Hassine, R.; Cherif, W. [Faculty of Sciences, Sfax University, Sfax, B.P. 1171-3000 (Tunisia); Sánchez-Benítez, J. [Departamento de Química Física I, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Mompean, F. J.; Alonso, J. A., E-mail: ja.alonso@icmm.csic.es [Instituto de Ciencia de Materiales de Madrid, Consejo Superior de Investigaciones Científicas, Cantoblanco, E-28049 Madrid (Spain); Fernández-Díaz, M. T. [Institut Laue-Langevin, B.P. 156, F-38042 Grenoble Cedex 9 (France); Elhalouani, F. [National School of Engineers, Sfax University, Sfax, B.P. W 3038 (Tunisia)

    2015-09-14

    New compounds of the series CaCu{sub 3}(Mn{sub 4−x}Al{sub x})O{sub 12} have been prepared under high pressure conditions (2 GPa), in the presence of KClO{sub 4} as oxidizing agent to stabilize Mn{sup 3+,4+} mixed valence. The polycrystalline samples have been characterized by x-ray diffraction, neutron powder diffraction (NPD), magnetic, and magnetotransport measurements. All the samples are cubic, space group Im-3. These oxides adopt a superstructure of ABO{sub 3} perovskite given by the long-range 1:3 ordering of Ca{sup 2+} and Cu{sup 2+} ions at the A sublattice. The NPD study for x = 0.4 shows that Al{sup 3+} ions are statistically distributed at the octahedral positions, being the (Mn,Al)O{sub 6} octahedra strongly tilted, with superexchange (Mn,Al)-O-(Mn,Al) angles of 142.1°. Also, neutron data clearly show that some Mn{sup 3+} ions (0.65(2) per formula) are located together with Cu{sup 2+} at the square-planar 6b positions. Regarding the magnetic properties, all the compounds present a spontaneous increase of the magnetization below T{sub C}, typical of ferro-or ferrimagnetic materials, with T{sub C} decreasing upon Al introduction. The magnetic structure determined from low-temperature NPD data unveils a ferromagnetic coupling between (Cu{sup 2+}, Mn{sup 3+}){sub 6b} spins and Mn{sub 8c} spins at octahedral positions; this is in contrast with the ferrimagnetic structure observed for RCu{sub 3}Mn{sub 4}O{sub 12} and CaCu{sub 3}Mn{sub 4}O{sub 12}, where an AFM coupling is observed between both magnetic sublattices. Interestingly, an enhancement of the magnetoresistance effect is observed for x = 0.2, well beyond that found for the parent compound. This effect, in materials subtly doped with non-magnetic elements at the Mn positions, may be of interest for applications.

  15. Electrical and magnetic behavior of La0.7Ca0.3MnO3/La0.7Sr0.2Ca0.1MnO3 composites

    International Nuclear Information System (INIS)

    Phong, P.T.; Dai, N.V.; Manh, D.H.; Thanh, T.D.; Khiem, N.V.; Hong, L.V.; Phuc, N.X.

    2010-01-01

    The electrical transport properties and the magnetoresistance of La 0.7 Ca 0.3 MnO 3 /La 0.7 Sr 0.2 Ca 0.1 MnO 3 composites are investigated as a function of sintering temperature. On the basis of an analysis by X-ray powder diffraction and scanning electron microscopy we suggest that raising the sintering temperature enhanced the interfacial reaction and creates interfacial phases at the boundaries of the La 0.7 Ca 0.3 MnO 3 and La 0.7 Sr 0.2 Ca 0.1 MnO 3 . Results also show that in 3 kOe, and at the Curie temperature, the magnetoresistance value of 14% was observed for the composite sintered at 1300 o C. Based on the phenomenological equation for conductivity under a percolation approach, which depends on the phase segregation of ferromagnetic metallic clusters and paramagnetic insulating regions, we fitted the experimental resistivity-temperature data from 50-300 K and find that the activation barrier decreases as temperature is increased.

  16. High-resolution T{sub 2}-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    Energy Technology Data Exchange (ETDEWEB)

    Hoogendam, Jacob P.; Verheijen, Rene H.M.; Zweemer, Ronald P. [University Medical Centre Utrecht, Department of Gynaecological Oncology, UMC Utrecht Cancer Centre, PO Box 85500, Utrecht (Netherlands); Kalleveen, Irene M.L.; Castro, Catalina S.A. de; Raaijmakers, Alexander J.E.; Bosch, Maurice A.A.J. van den; Klomp, Dennis W.J.; Veldhuis, Wouter B. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2017-03-15

    We studied the feasibility of high-resolution T{sub 2}-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B{sub 1} {sup +} shimming, T{sub 2}-weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T{sub 2}-weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B{sub 1} interference, excessive B{sub 1} under the external antennae and SENSE reconstruction. High-resolution T{sub 2}-weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. (orig.)

  17. MRI of the cervical spine with T1-weighted multislice flash sequences

    International Nuclear Information System (INIS)

    Schubeus, P.; Sander, B.; Schoerner, W.; Tosch, U.; Lanksch, W.R.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1990-01-01

    A study has been carried out to evaluate contrast and image quality of cervical structures using multislice 2D-flash sequences with long repetition times (TR = 400 ms.) and short echo delay times (TE = 5.8 ms.). The examinations were carried out using ten normals with an MRI of 1.5 Tesla and flip angles of 10, 20, 30, 50, 70 and 90deg. The best contrast between intervertebral disc and surrounding tissue was obtained between 50 and 70deg, best contrast between compact bone and CSF with 10deg. In order to demonstrate degenerative changes of the cervical spine, it appears sensible to use a combination of these angles. The described sequences produce good images of the cervical structures with little image degradation. Compared to T 1 -weighted spin-echo sequences, the method has a number of significant advantages, such as variations in image contrast, higher maximal number of slices, continuous imaging and less imaging time. (orig.) [de

  18. Normalization of white matter intensity on T1-weighted images of patients with acquired central nervous system demyelination.

    Science.gov (United States)

    Ghassemi, Rezwan; Brown, Robert; Narayanan, Sridar; Banwell, Brenda; Nakamura, Kunio; Arnold, Douglas L

    2015-01-01

    Intensity variation between magnetic resonance images (MRI) hinders comparison of tissue intensity distributions in multicenter MRI studies of brain diseases. The available intensity normalization techniques generally work well in healthy subjects but not in the presence of pathologies that affect tissue intensity. One such disease is multiple sclerosis (MS), which is associated with lesions that prominently affect white matter (WM). To develop a T1-weighted (T1w) image intensity normalization method that is independent of WM intensity, and to quantitatively evaluate its performance. We calculated median intensity of grey matter and intraconal orbital fat on T1w images. Using these two reference tissue intensities we calculated a linear normalization function and applied this to the T1w images to produce normalized T1w (NT1) images. We assessed performance of our normalization method for interscanner, interprotocol, and longitudinal normalization variability, and calculated the utility of the normalization method for lesion analyses in clinical trials. Statistical modeling showed marked decreases in T1w intensity differences after normalization (P < .0001). We developed a WM-independent T1w MRI normalization method and tested its performance. This method is suitable for longitudinal multicenter clinical studies for the assessment of the recovery or progression of disease affecting WM. Copyright © 2014 by the American Society of Neuroimaging.

  19. Elevated electrochemical performance of (NH4)3AlF6-coated 0.5Li2MnO3·0.5LiNi1/3Co1/3Mn1/3O2 cathode material via a novel wet coating method

    International Nuclear Information System (INIS)

    Xu, Guofeng; Li, Jianling; Xue, Qingrui; Dai, Yu; Zhou, Hongwei; Wang, Xindong; Kang, Feiyu

    2014-01-01

    A novel wet method of (NH 4 ) 3 AlF 6 coating was explored to enhance the electrochemical performance of Mn-based solid-solution cathode material 0.5Li 2 MnO 3 ·0.5LiNi 1/3 Co 1/3 Mn 1/3 O 2 . The X-ray powder diffraction patterns show that the coating material is pure-phase (NH 4 ) 3 AlF 6 and both pristine and coated samples can be indexed to hexagonal α-NaFeO 2 layered structure with space group of R-3 m. The field-emission scanning electron microscope images and the energy dispersive X-ray spectroscopy show that (NH 4 ) 3 AlF 6 is successfully coated on the surface of active particle. The (NH 4 ) 3 AlF 6 coated electrodes exhibit improved electrochemical performance, for instance, the initial charge-discharge efficiency was promoted by 5% (NH 4 ) 3 AlF 6 coating, the 1 wt.% and 3 wt.% coated electrodes deliver elevated cycling ability which is ascribed to the lower resistance between electrode and electrolyte as indicated by AC impedance measurement at different cycles. In addition, the coated-electrodes also give enhanced rate capability particularly for 1 wt.% NAF-coated electrode performing surprising capacity of 143.4 mAh g −1 at 5 C higher than that of 109.4 mAh g −1 for pristine electrode. Furthermore, the 1 wt.% NAF-coated electrode also shows improved cycle and rate performance at 55°C

  20. Synthesis, microstructure and EPR of CaMnO{sub 3} and Eu{sub x}Ca{sub 1-x}MnO{sub 3} manganite, obtained by coprecipitation

    Energy Technology Data Exchange (ETDEWEB)

    Santiago T, M.; Hernandez C, L.; Legorreta G, F. [Universidad Autonoma del Estado de Hidalgo, AACTyM, Carretera Pachuca-Tulancingo Km 4.5, 42074 Pachuca, Hidalgo (Mexico); Montiel S, H. [UNAM, Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Departamento de Tecnociencias, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Alvarez L, G. [IPN, Escuela Superior de Fisica y Matematicas, Departamento de Fisica, U. P. Adolfo Lopez Mateos, Edif. 9, Col. Lindavista, 07738 Mexico D. F. (Mexico); Flores G, M. A., E-mail: mar200878@hotmail.com [Universidad Politecnica de Pachuca, Laboratorio de Nanotecnologia y Bioelectromagnetismo Aplicado, Carretera Pachuca-Cd. Sahagun Km 20, Ex-Hacienda de Santa Barbara, 43830 Zempoala, Hidalgo (Mexico)

    2011-07-01

    The synthesis of CaMnO{sub 3} and Eu{sub x}Ca{sub 1-x}MnO{sub 3} obtained by coprecipitation method is showed. The synthesized samples were characterized by X-ray diffraction and scanning electronic microscopy, the powders showed orthorhombic structure and pnma space group. When it was doped with Europium, their morphology tendency was spherical. Measurements were carried out on electron paramagnetic resonance (EPR) with constant frequency = 9.4 GHz (band X) and dc magnetic field (H dc) 0-0.8 T, measurements were at 300 K and 77 K. EPR spectra showed significant differences between both samples, indicating that the substitution of divalent alkaline earth cations by trivalent rare earth ions, allowing the formation of a mixed valence state of manganese, Mn{sup 3+} and Mn{sup 4+}. A 77 K, the manganite of concentration x = 0.30 had a magnetic ordering, noted by the presence of hysteresis. (Author)

  1. A new rechargeable lithium-ion battery with a xLi2MnO3.(1 - x) LiMn0.4Ni0.4Co0.2O2 cathode and a hard carbon anode

    International Nuclear Information System (INIS)

    Liu Jinlong; Wang Jie; Xia Yongyao

    2011-01-01

    Highlights: → A new type of battery with 0.4Li 2 MnO 3 0.6LiMn 0.4 Ni 0.4 Co 0.2 O 2 and hard carbon was proposed. → The irreversible capacity encountered at both electrodes, can be counterbalanced each other. → The battery delivers capacities of 105 mAh g -1 and specific energies of 315 Wh kg -1 . - Abstract: We reported a new type of rechargeable lithium-ion battery consisting of a structurally integrated 0.4Li 2 MnO 3 .0.6LiMnNi 0.4 Co 0.2 O 2 cathode and a hard carbon anode. The drawback of the high irreversible capacity loss of both electrodes, occurring at the first charge/discharge process, can be counterbalanced each other. The battery shows good reversibility with a sloping voltage from 1.5 V to 4.5 V and delivers a capacity of 105 mA h g -1 and a specific energy of 315 W h kg -1 based on the total weight of the both active electrode materials.

  2. MR imaging of hematopoietic regions in bone marrow of aplastic anemia. Diagnostic usefulness of opposed phase T1-weighted images

    Energy Technology Data Exchange (ETDEWEB)

    Amano, Yasuo; Tanabe, Yoshihiro; Amano, Maki; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-01-01

    The signal intensity of hematopoietic regions in the marrow of aplastic anemia were investigated on opposed phase T1-weighted images (op-T1WI) with a 0.5-Tesla MR unit. Hematopoietic regions were classified into two groups: low intensity hematopoietic areas (LH) isointense to normal marrow and high intensity hematopoietic regions (HH) with higher intensity than normal marrow on op-T1WI. The signal intensity of LH was significantly lower than that of HH on STIR. LH converted into HH with improvement of laboratory data after therapy, whereas HH decreased with impairment of data. HH were hyperintense to cerebrospinal fluid on op-T1WI. These results indicated that the signal intensity of hematopoietic regions on op-T1WI reflected the cellularity in these regions and that aplastic anemia included hypercellular regions relative to normal marrow. (author).

  3. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  4. Methods of fast, multiple-point in vivo T1 determination

    International Nuclear Information System (INIS)

    Zhang, Y.; Spigarelli, M.; Fencil, L.E.; Yeung, H.N.

    1989-01-01

    Two methods of rapid, multiple-point determination of T1 in vivo have been evaluated with a phantom consisting of vials of gel in different Mn + + concentrations. The first method was an inversion-recovery- on-the-fly technique, and the second method used a variable- tip-angle (α) progressive saturation with two sub- sequences of different repetition times. In the first method, 1/T1 was evaluated by an exponential fit. In the second method, 1/T1 was obtained iteratively with a linear fit and then readjusted together with α to a model equation until self-consistency was reached

  5. Magneto-resistive coefficient enhancement observed around Verwey-like transition on spinel ferrites XFe{sub 2}O{sub 4} (X = Mn, Zn)

    Energy Technology Data Exchange (ETDEWEB)

    López Maldonado, K. L., E-mail: liliana.lopez.maldonado@gmail.com; Vazquez Zubiate, L.; Elizalde Galindo, J. T. [Instituto de Ingeniería y Tecnología, Universidad Autónoma de Ciudad Juárez, Av. Del Charro 450 norte, 32310 Ciudad Juárez (Mexico); Presa, P. de la [Instituto de Magnetismo Aplicado (UCM-ADIF-CSIC), P.O. Box 155, 28230 Las Rozas (Spain); Departamento de Física de Materiales, Univ. Complutense de Madrid, Madrid (Spain); Matutes Aquino, J. A. [Centro de Investigación en Materiales Avanzados, Miguel de Cervantes 120, 31109 Chihuahua (Mexico)

    2014-05-07

    Manganese and Zinc ferrites were prepared by solid state reaction. The resulting powders were pressed into pellets and heat treated at 1100 °C. The samples were characterized by using X-ray diffraction, pure phases of zinc ferrite (ZnFe{sub 2}O{sub 4}) and manganese ferrite (MnFe{sub 2}O{sub 4}) were obtained. Scanning electron microscopy images showed a good contact between particles. A drop of electrical resistance was found in both samples, MnFe{sub 2}O{sub 4} and ZnFe{sub 2}O{sub 4}, with values going from 2750 to 130 Ω and from 1100 to 55 Ω, respectively. Transition temperatures were determined to be T{sub V} = 225 K for MnFe{sub 2}O{sub 4} and T{sub V} = 130 K for ZnFe{sub 2}O{sub 4}. Magnetoresistance measurements were carried out in the temperature range where R showed the transition, defined as the Verwey-like transition temperature range, ΔT{sub V}. No magnetoresistive effect was observed out of it. The magnetoresistive coefficient (MRC) observed at ΔT{sub V} reached its maximum values of 1.1% for MnFe{sub 2}O{sub 4} and 6.68% for ZnFe{sub 2}O{sub 4}. The differences between MRC values are related to the divalent metal element used. Finally, the magnetoresistive response indicates that the electrical transition observed is strongly influencing the magnetoresistance; where the underlying responsible for this behavior could be a charge reordering occurring at the Verwey-like transition temperature.

  6. Effects of electric-field-induced piezoelectric strain on the electronic transport properties of La0.9Ce0.1MnO3 thin films

    International Nuclear Information System (INIS)

    Zheng, R.K.; Dong, S.N.; Wu, Y.Q.; Zhu, Q.X.; Wang, Y.; Chan, H.L.W.; Li, X.M.; Luo, H.S.; Li, X.G.

    2012-01-01

    The authors constructed multiferroic structures by growing La 0.9 Ce 0.1 MnO 3 (LCEMO) thin films on piezoelectric 0.68Pb(Mg 1/3 Nb 2/3 )O 3 –0.32PbTiO 3 (PMN-PT) single-crystal substrates. Due to the efficient elastic coupling at the interface, the electric-field-induced piezoelectric strain in PMN-PT substrates is effectively transferred to LCEMO films and thus, leads to a decrease in the resistance and an increase in the magnetoresistance of the films. Particularly, it was found that the resistance-strain coefficient [(ΔR/R) film /(Δε zz ) film ] of the LCEMO film was considerably enhanced by the application of magnetic fields, demonstrating strong coupling between the lattice and the spin degrees of freedom. (ΔR/R) film /(Δε zz ) film at 122 K was enhanced by ∼ 28.8% by a magnetic field of 1.2 T. An analysis of the overall results demonstrates that the phase separation is crucial to understand strain-mediated modulation of electronic transport properties of manganite film/PMN-PT multiferroic structures. - Highlights: ► La 0.9 Ce 0.1 Mn O3 films were epitaxially grown on piezoelectric single crystals. ► Piezoelectric strain influences the electronic transport properties of films. ► Magnetic field enhances the piezoelectric strain effect. ► Phase separation is crucial to understand the piezoelectric strain effect.

  7. Whole Body MRI at 3T with Quantitative Diffusion Weighted Imaging and Contrast-Enhanced Sequences for the Characterization of Peripheral Lesions in Patients with Neurofibromatosis Type 2 and Schwannomatosis

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Blakeley, Jaishri; Plotkin, Scott; Widemann, Brigitte; Jacobs, Michael A.

    2013-01-01

    Purpose. WB-MRI is mainly used for tumor detection and surveillance. The purpose of this study is to establish the feasibility of WB-MRI at 3T for lesion characterization, with DWI/ADC-mapping and contrast-enhanced sequences, in patients with neurofibromatosis type 2 (NF-2) and schwannomatosis. Materials and Methods. At 3T, WB-MRI was performed in 11 subjects (10 NF-2 and 1 schwannomatosis) with STIR, T1, contrast-enhanced T1, and DWI/ADC mapping (b = 50, 400, 800 s/mm 2 ). Two readers reviewed imaging for the presence and character of peripheral lesions. Lesion size and features (signal intensity, heterogeneity, enhancement characteristics, and ADC values) were recorded. Descriptive statistics were reported. Results. Twenty-three lesions were identified, with average size of 4.6 ± 2.8 cm. Lesions were characterized as tumors (21/23) or cysts (2/23) by contrast-enhancement properties (enhancement in tumors, no enhancement in cysts). On T1, tumors were homogeneously isointense (5/21) or hypointense (16/21); on STIR, tumors were hyperintense and homogeneous (10/21) or heterogeneous (11/21); on postcontrast T1, tumors enhanced homogeneously (14/21) or heterogeneously (7/21); on DWI, tumor ADC values were variable (range 0.8–2.7), suggesting variability in intrinsic tumor properties. Conclusion. WB-MRI with quantitative DWI and contrast-enhanced sequences at 3T is feasible and advances the utility of WB-MRI not only to include detection, but also to provide additional metrics for lesion characterization

  8. Thermodynamic properties of multiferroic Mg doped YbMnO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Sattibabu, Bhumireddi, E-mail: bsb.satti@gmail.com [School of Engineering Sciences and Technology, University of Hyderabad, Hyderabad 500046 (India); Bhatnagar, A.K., E-mail: anilb42@gmail.com [School of Engineering Sciences and Technology, University of Hyderabad, Hyderabad 500046 (India); School of Physics, University of Hyderabad, Hyderabad 500046 (India); Samatham, S. Shanmukharao; Singh, D. [Low Temperature Laboratory, UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore 452001, M.P. (India); Rayaprol, S. [UGC-DAE Consortium for Scientific Research, Mumbai Centre, BARC Campus, Mumbai 400085 (India); Das, D. [School of Engineering Sciences and Technology, University of Hyderabad, Hyderabad 500046 (India); Siruguri, V. [UGC-DAE Consortium for Scientific Research, Mumbai Centre, BARC Campus, Mumbai 400085 (India); Ganesan, V. [Low Temperature Laboratory, UGC-DAE Consortium for Scientific Research, University Campus, Khandwa Road, Indore 452001, M.P. (India)

    2015-09-25

    Highlights: • Specific heat data shows that T{sub N} increases for Mg doped YbMnO{sub 3} from 83 K to 86 K. • Yb{sub 1−x}Mg{sub x}MnO{sub 3} (x = 0.0 and 0.05) shows multiple magnetic transitions. • RCP are found to be 26.1 J/mol and 27.2 J/mol for YbMnO{sub 3} and Yb{sub 0.95}Mg{sub 0.05}MnO{sub 3}. - Abstract: Calorimetric studies of polycrystalline samples Yb{sub 1−x}Mg{sub x}MnO{sub 3} with x = 0.0 and 0.05 are reported. It is revealed that the Mg doping raises the antiferromagnetic ordering temperature, T{sub N,} from 83 K for x = 0.0 to 86 K for x = 0.05. A ferromagnetic ordering is also observed around 3 K. The broad feature in the specific heat data just above ferromagnetic ordering, is attributed to the Schottky anomaly. The estimated effective molecular fields from the Schottky analysis are H{sub mf} = 3.0 and 3.5 T for YbMnO{sub 3} and Yb{sub 0.95}Mg{sub 0.05}MnO{sub 3}, respectively. High temperature shift of Schottky anomaly with Mg doping indicates increase in effective molecular field of Mn at the Yb 4b site. The data supports that the idea that although molecular field is mainly responsible for the Schottky anomaly in Yb{sub 1−x}Mg{sub x}MnO{sub 3} and Mn{sup 3+} spin ordering also affects it. Magnetic part of the specific heat is obtained by subtracting the lattice contribution estimated using two Debye temperatures. The magnetic entropy change (ΔS{sub mag}) for pure and doped samples are 2.0 J mol{sup −1} K{sup −1} and 2.1 J mol{sup −1} K{sup −1} respectively, while the relative cooling power (RCP) calculate 26.1 J/mol, 27.2 J/mol for a field change of 10 T.

  9. X-ray absorption measurements of charge-ordered La{sub 0.5}Sr{sub 1.5}MnO{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, T.; Villella, P.M.; Dessau, D.S. [Univ. of Colorado, Boulder, CO (United States)] [and others

    1997-04-01

    Perovskite and {open_quotes}layered perovskite{close_quotes}-type manganese oxides show a variety of electronic and magnetic properties such as the colossal magnetoresistance (CMR) or the charge ordering. Among them, La{sub 0.5}Sr{sub 1.5}MnO{sub 4} (K{sub 2}NiF{sub 4} structure) which has 0.5 holes per Mn site (d{sup 3.5}) shows the charge-order transition at {approximately}220 K below which Mn{sup 3+} and Mn{sup 4+} sites are believed to order in the CE-type. Although the charge ordering phenomenon has also been observed in the perovskite manganites Pr{sub 0.5}Sr{sub 1.5}MnO{sub 3} or Pr{sub 0.5}Ca{sub 1.5}MnO{sub 3}, the present system has another advantage that it has a layered structure. This enables the authors to address the issue of the orbital symmetry which should be directly related to the charge ordering. In this report, they present the results of x-ray absorption spectroscopy (XAS) on La{sub 0.5}Sr{sub 1.5}MnO{sub 4}, for two polarization angles and two (above and below the transition temperature T{sub CO}) temperatures.

  10. Effects of high vacancy concentrations on the magnetic properties of La1-xMn1-yO3 (0.02≤x, y≤0.13)

    International Nuclear Information System (INIS)

    Silva, P.S. de; Richards, F.M.; Cohen, L.F.; Alonso, J.A.; Martinez-Lope, M.J.; Casais, M.T.; Thomas, K.A.; MacManus-Driscoll, J.L.

    1998-01-01

    It has been found that the synthesis conditions and subsequent annealing treatments can significantly change the magnetic and transport behavior of the colossal magnetoresistive materials of the general formula La 1-z A z MnO 3 , where A is a divalent ion. In order to clarify the role of vacancies within this structure, resistivity and magnetization measurements have been carried out on a series of samples derived from the parent compound LaMnO 3 , with La and Mn vacancies introduced by systematically varying the oxygen annealing conditions. Previous studies have shown that for a given carrier concentration, the Curie temperature of the paramagnetic to ferromagnetic transition (T c ) increases as the tolerance factor of the perovskite structure increases and then begins to decrease slowly for even higher tolerance factors. Generally, T c also increases with the Mn 4+ content, consistent with a double exchange mechanism responsible for ferromagnetism. In this study T c was found to decrease as the vacancy concentration (and therefore the Mn 4+ concentration) and tolerance factor both increase. The magnetic and transport data are discussed in the light of structural information obtained from neutron diffraction studies. In the present study it is found that La and Mn vacancies play a significant role in determining the physical properties of these materials: for high vacancy concentrations (x,y≥0.080) the magnetic properties are analogous to those of spin glasses associated with disorder and frustration. Semiconductorlike resistivity was observed for all samples at all temperatures. copyright 1998 American Institute of Physics

  11. Structural, Raman, and dielectric studies on multiferroic Mn-doped Bi 1-xLax FeO 3 ceramics

    KAUST Repository

    Xing, Zhibiao

    2014-04-03

    Multiferroic Bi1-xLaxFeO3 [BLFO (x)] ceramics with x = 0.10-0.50 and Mn-doped BLFO (x = 0.30) ceramics with different doping contents (0.1-1.0 mol%) were prepared by solid-state reaction method. They were crystallized in a perovskite phase with rhombohedral symmetry. In the BLFO (x) system, a composition (x)-driven structural transformation (R3c→C222) was observed at x = 0.30. The formation of Bi2Fe 4O9 impure phase was effectively suppressed with increasing the x value, and the rhombohedral distortion in the BLFO ceramics was decreased, leading to some Raman active modes disappeared. A significant red frequency shift (~13 cm-1) of the Raman mode of 232 cm-1 in the BLFO ceramics was observed, which strongly perceived a significant destabilization in the octahedral oxygen chains, and in turn affected the local FeO6 octahedral environment. In the Mn-doped BLFO (x = 0.30) ceramics, the intensity of the Raman mode near 628 cm-1 was increased with increasing the Mn-doping content, which was resulted from an enhanced local Jahn-Teller distortions of the (Mn,Fe)O6 octahedra. Electron microscopy images revealed some changes in the ceramic grain sizes and their morphologies in the Mn-doped samples at different contents. Wedge-shaped 71° ferroelectric domains with domain walls lying on the {110} planes were observed in the BLFO (x = 0.30) ceramics, whereas in the 1.0 mol% Mn-doped BLFO (x = 0.30) samples, 71° ferroelectric domains exhibited a parallel band-shaped morphology with average domain width of 95 nm. Dielectric studies revealed that high dielectric loss of the BLFO (x = 0.30) ceramics was drastically reduced from 0.8 to 0.01 (measured @ 104 Hz) via 1.0 mol% Mn-doping. The underlying mechanisms can be understood by a charge disproportion between the Mn4+ and Fe2+ in the Mn-doped samples, where a reaction of Mn4+ + Fe2+→Mn3+ + Fe3+ is taken place, resulting in the reduction in the oxygen vacancies and a suppression of the electron hopping from Fe3+ to Fe2+ ions

  12. Structural, Raman, and dielectric studies on multiferroic Mn-doped Bi 1-xLax FeO 3 ceramics

    KAUST Repository

    Xing, Zhibiao; Zhu, Xinhua; Zhu, Jianmin; Liu, Zhiguo; Al-Kassab, Talaat

    2014-01-01

    Multiferroic Bi1-xLaxFeO3 [BLFO (x)] ceramics with x = 0.10-0.50 and Mn-doped BLFO (x = 0.30) ceramics with different doping contents (0.1-1.0 mol%) were prepared by solid-state reaction method. They were crystallized in a perovskite phase with rhombohedral symmetry. In the BLFO (x) system, a composition (x)-driven structural transformation (R3c→C222) was observed at x = 0.30. The formation of Bi2Fe 4O9 impure phase was effectively suppressed with increasing the x value, and the rhombohedral distortion in the BLFO ceramics was decreased, leading to some Raman active modes disappeared. A significant red frequency shift (~13 cm-1) of the Raman mode of 232 cm-1 in the BLFO ceramics was observed, which strongly perceived a significant destabilization in the octahedral oxygen chains, and in turn affected the local FeO6 octahedral environment. In the Mn-doped BLFO (x = 0.30) ceramics, the intensity of the Raman mode near 628 cm-1 was increased with increasing the Mn-doping content, which was resulted from an enhanced local Jahn-Teller distortions of the (Mn,Fe)O6 octahedra. Electron microscopy images revealed some changes in the ceramic grain sizes and their morphologies in the Mn-doped samples at different contents. Wedge-shaped 71° ferroelectric domains with domain walls lying on the {110} planes were observed in the BLFO (x = 0.30) ceramics, whereas in the 1.0 mol% Mn-doped BLFO (x = 0.30) samples, 71° ferroelectric domains exhibited a parallel band-shaped morphology with average domain width of 95 nm. Dielectric studies revealed that high dielectric loss of the BLFO (x = 0.30) ceramics was drastically reduced from 0.8 to 0.01 (measured @ 104 Hz) via 1.0 mol% Mn-doping. The underlying mechanisms can be understood by a charge disproportion between the Mn4+ and Fe2+ in the Mn-doped samples, where a reaction of Mn4+ + Fe2+→Mn3+ + Fe3+ is taken place, resulting in the reduction in the oxygen vacancies and a suppression of the electron hopping from Fe3+ to Fe2+ ions

  13. Soft-tissue and bone lesions examined with 1.5-T MR imaging and Gd-DOTA

    International Nuclear Information System (INIS)

    VonSchulthess, G.K.; Kuoni, W.; Wuthrich, R.; Duewell, S.; Thurnher, S.; Marincek, B.

    1988-01-01

    Fifteen patients with soft-tissue masses or bone lesions underwent 16 MR imaging examinations with gadolinium-DOTA, a new MR contrast agent. T1- and T2-weighted precontrast sequences were obtained. The contrast agent was injected in a concentration of 0.1 mmol/kg without any untoward effects. After contrast examination, one or two T1-weighted sequences were obtained. Contrast medium application improved the distinction between lesion and edema in four of seven cases, between the lesion and central necrosis in seven of eight cases, and between the lesion, and the surrounding tissues in four of 12 cases. In eight of 12 cases, additional structures within the lesion were noted after Gd-DOTA enhancement. Of particular benefit was the use of contrast media to evaluate the vascularization of the lesion (in 12 of 14 cases)

  14. Surface activation of MnNb{sub 2}O{sub 6} nanosheets by oxalic acid for enhanced photocatalysis

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Junshu; Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Li, Hongyi; Li, Yongli; Du, Yucheng; Yang, Yilong; Jia, Xinjian

    2017-05-01

    Graphical abstract: Visible light driven photoreduction of Cr(VI) over MnNb{sub 2}O{sub 6} nanosheets is enhanced via oxalic acid surface complex to generate activation layer. - Highlights: • MnNb{sub 2}O{sub 6} nanosheets are crystallized by a surface capping route of sulfonate groups. • Oxalic acid on MnNb{sub 2}O{sub 6} nanosheets forms an excited surface complex hybrid layer. • Surface activation enhances visible-light induced reduction of Cr(VI) into Cr(III). - Abstract: MnNb{sub 2}O{sub 6} nanosheets (P-MNOs) is selectively crystallized by using surface capping ligand with functional sulfonate group (sodium dodecyl benzene sulphonate), which binds to the (131) surface of MnNb{sub 2}O{sub 6} inducing the morphology-controlled crystallization of MnNb{sub 2}O{sub 6} materials. Surface modification of photoactive P-MNOs with electron-rich oxalic acid ligands establishes an excited surface complex layer on phase-pure P-MNO as evidenced by spectroscopic analyses (FT-IR, UV–vis, Raman, PL, etc.), and thus more efficiently photocatalyzes the reduction of Cr(VI) into Cr(III) than solely P-MNOs or oxalic acid under visible light (λ > 420 nm) via a ligand-to-metal interfacial electron transfer pathway. However, the interaction between oxalic acid and MnNb{sub 2}O{sub 6} is highly dependent upon the morphology of solid MnNb{sub 2}O{sub 6} substrate due to the higher surface-area-to-volume ratio and higher surface activity of (131) planes in the sheet-like morphology. This study could assist the construction of stable niobate material systems to allow a versatile solid surface activation for establishing more energy efficient and robust catalysis process under visible light.

  15. Microwave assisted synthesis of core–shell LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C nanocomposite cathode for high-performance lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Li, Huanhuan [Automotive Engineering Research Institute, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013 (China); Li, Yunxing [School of Material Science and Engineering, Jiangsu University, Zhenjiang 212013 (China); Chen, Long; Jiang, Haobin [Automotive Engineering Research Institute, Jiangsu University, 301 Xuefu Road, Zhenjiang 212013 (China); Wei, Jinping [Institute of New Energy Material Chemistry, Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), Nankai University, Tianjin 300071 (China); Wang, Hongbo [China Aviation Lithium Battery Co. Ltd., Luoyang 471003 (China); Wang, Yaping, E-mail: wangyaping@ujs.edu.cn [School of Material Science and Engineering, Jiangsu University, Zhenjiang 212013 (China)

    2014-12-25

    Highlights: • We firstly report a fast microwave heating way to prepare LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C. • The reversible discharge capacity of LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C is about 169 mA h g{sup −1}. • LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C nanocomposite elucidates excellent cyclic stability. • LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C nanocomposite exhibits attractive rate capability. - Abstract: A microwave assisted method is developed for synthesizing pure LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4} and LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C nanocomposite. Olivine LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4} coated with uniform amorphous carbon film of ∼5 nm in thickness with an average size of ∼200 nm is successfully obtained. Compared with pure LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}, LiFe{sub 1/3}Mn{sub 1/3}Co{sub 1/3}PO{sub 4}/C composite presents enhanced electrochemical Li-ion intercalation performances. It exhibits a high discharge capacity of 169 mA h g{sup −1} at 0.1 C (theoretical capacity is 170 mA h g{sup −1}). The capacity retention is 99% after 30 cycles. Furthermore, the capacities are still retained 101 at 5 C and 76 mA h g{sup −1} and 20 C, respectively. Carbon coating can significantly improve the Li-ion diffusion, the reversibility of lithium extraction/insertion and electrical conductivity of LiCo{sub 1/3}Mn{sub 1/3}Fe{sub 1/3}PO{sub 4}.

  16. “Hot cross bun” sign in multiple system atrophy with predominant cerebellar ataxia: A comparison between proton density-weighted imaging and T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kasahara, Seiko, E-mail: nuun077@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Miki, Yukio, E-mail: yukio.miki@med.osaka-cu.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545–8585 (Japan); Kanagaki, Mitsunori, E-mail: mitsuk@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Kondo, Takayuki, E-mail: kondotak@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Yamamoto, Akira, E-mail: yakira@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Morimoto, Emiko, E-mail: foresta@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Ito, Hidefumi, E-mail: itohid@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Takahashi, Ryosuke, E-mail: ryosuket@kuhp.kyoto-u.ac.jp [Department of Neurology, Kyoto University Graduate School of Medicine, 54 Shogoin-Kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); and others

    2012-10-15

    Objective: To investigate whether proton density-weighted imaging can detect the “hot cross bun” sign in the pons in multiple system atrophy with predominant cerebellar ataxia significantly better than T2-weighted imaging at 3 T. Methods: Sixteen consecutive patients with multiple system atrophy with predominant cerebellar ataxia according to the Consensus Criteria were reviewed. Axial unenhanced proton density-weighted imaging and T2-weighted imaging were obtained using a dual-echo fast spin-echo sequence at 3 T. Two neuroradiologists independently evaluated visualisation of the abnormal pontine signal using a 4-point visual grade from Grade 0 (no “hot cross bun” sign) to Grade 3 (prominent “hot cross bun” sign on two or more sequential slices). Differences in grade between proton density-weighted imaging and T2-weighted imaging were statistically analysed using the Wilcoxon signed-rank test. Results: In 11 patients (69%), a higher grade was given for proton density-weighted imaging than T2-weighted imaging. In 1 patient (6%), grades were the same (Grade 3) on both images. In the remaining 4 patients (25%), signal abnormalities were not detected on either image (Grade 0). The “hot cross bun” sign was thus observed significantly better on proton density-weighted imaging than on T2-weighted imaging (P = 0.001). Conclusions: The “hot cross bun” sign considered diagnostic for multiple system atrophy with predominant cerebellar ataxia is significantly better visualised on proton density-weighted imaging than on T2-weighted imaging at 3 T.

  17. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    Energy Technology Data Exchange (ETDEWEB)

    Radlbauer, Rudolf, E-mail: rudolf.radlbauer@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Lomoschitz, Friedrich, E-mail: friedrich.lomoschitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Salomonowitz, Erich, E-mail: erich.salomonowitz@stpoelten.lknoe.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Eberhardt, Knut E., E-mail: info@mrt-kompetenzzentrum.d [MRT Competence Center Schloss Werneck, Balthasar-Neumann-Platz 2, 97440 Werneck (Germany); Stadlbauer, Andreas, E-mail: andi@nmr.a [MR Physics Group, Department of Radiology, Landesklinikum St. Poelten, Propst Fuehrer Strasse 4, 3100 St. Poelten (Austria); Department of Neurosurgery, University of Erlangen-Nuremberg, Schwabachanlage 6, 91054 Erlangen (Germany)

    2010-08-15

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  18. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse

    International Nuclear Information System (INIS)

    Radlbauer, Rudolf; Lomoschitz, Friedrich; Salomonowitz, Erich; Eberhardt, Knut E.; Stadlbauer, Andreas

    2010-01-01

    The purpose of this study was to assess the effect of a driven equilibrium (DRIVE) pulse incorporated in a standard T1-weighted turbo spin echo (TSE) sequence as used in our routine MRI protocol for examination of pathologies of the knee. Sixteen consecutive patients with knee disorders were examined using the routine MRI protocol, including T1-weighted TSE-sequences with and without a DRIVE pulse. Signal-to-noise ratios (SNRs) and contrast-to-noise ratio (CNR) of anatomical structures and pathologies were calculated and compared for both sequences. The differences in diagnostic value of the T1-weighted images with and without DRIVE pulse were assessed. SNR was significantly higher on images acquired with DRIVE pulse for fluid, effusion, cartilage and bone. Differences in the SNR of meniscus and muscle between the two sequences were not statistically significant. CNR was significantly increased between muscle and effusion, fluid and cartilage, fluid and meniscus, cartilage and meniscus, bone and cartilage on images acquired using the DRIVE pulse. Diagnostic value of the T1-weighted images was found to be improved for delineation of anatomic structures and for diagnosing a variety of pathologies when a DRIVE pulse is incorporated in the sequence. Incorporation of a DRIVE pulse into a standard T1-weighted TSE-sequence leads to significant increase of SNR and CNR of both, anatomical structures and pathologies, and consequently to an increase in diagnostic value within the same acquisition time.

  19. [The use of the T2-weighted turbo-spin-echo sequence in studying the neurocranium. A comparison with the conventional T2-weighted spin-echo sequence].

    Science.gov (United States)

    Siewert, C; Hosten, N; Felix, R

    1994-07-01

    T2-weighted spin-echo imaging is the standard screening procedure in MR imaging of the neurocranium. We evaluated fast spin-echo T2-weighted imaging (TT2) of the neurocranium in comparison to conventional spin-echo T2-weighted imaging (T2). Signal-to-noise and contrast-to-noise ratio of normal brain tissues (basal ganglia, grey and white matter, CSF fluid) and different pathologies were calculated. Signal-to-noise ratio and contrast-to-noise ratio were significantly higher in TT2 than in T2 (with the exception of gray-to-white matter contrast). Tissues with increased content of water protons (mobile protons) showed the highest contrast to surrounding tissues. The increased signal intensity of fat must be given due attention in fatty lesions. Because the contrast-to-noise ratio between white matter and basal ganglia is less in TT2, Parkinson patients have to be examined by conventional T2. If these limitations are taken into account, fast spin-echo T2-weighted imaging is well appropriate for MR imaging of the neurocranium, resulting in heavy T2-weighting achieved in a short acquisition time.

  20. Martensitic transformation and magnetic properties of manganese-rich Ni-Mn-In and Ni-Mn-Sn Heusler alloys; Untersuchung der martensitischen Umwandlung und der magnetischen Eigenschaften Mangan-reicher Ni-Mn-In- und Ni-Mn-Sn-Heusler-Legierungen

    Energy Technology Data Exchange (ETDEWEB)

    Krenke, T.

    2007-06-29

    In the present work, the martensitic transition and the magnetic properties of Manganese rich Ni{sub 50}Mn{sub 50-x}Sn{sub x} and Ni{sub 50}Mn{sub 50-y}In{sub y} alloys with 5 at%{<=}x(y){<=}25 at% were investigated. Calorimetry, X-ray and neutron diffraction, magnetization, and strain measurements were performed on polycrystalline samples. It was shown that alloys close to the stoichiometric composition Ni{sub 50}Mn{sub 25}Sn{sub 25} and Ni{sub 50}Mn{sub 25}Sn{sub 25} do not exhibit a structural transition on lowering of the temperature, whereas alloys with x{<=}15 at% Tin and y{<=}16 at% Indium transform martensitically. The structural transition temperatures increase linearly with decreasing Tin or Indium content. The crystal structures of the low temperature martensite are modulated as well as unmodulated. Alloys with compositions close to stoichiometry are dominated by ferromagnetic interactions, whereas those close to the binary composition Ni{sub 50}Mn{sub 50} order antiferromagnetically. Ferromagnetic order and structural instability coexist in a narrow composition range between 13 at%{<=}x{<=}15 at% and 15 at%{<=}x{<=}16 at% for Ni{sub 50}Mn{sub 50-x}Sn{sub x} and Ni{sub 50}Mn{sub 50-y}In{sub y} respectively. As a consequence, interesting magnetoelastic effects are observed. The Ni{sub 50}Mn{sub 34}In{sub 16} alloy shows a magnetic field-induced structural transition, whereby application of an external magnetic field in the martensitic state stabilizes the high temperature L2{sub 1} structure. Evidence for this was given by neutron diffraction experiments in external magnetic fields. Moreover, the structural transition temperatures of this alloy show large magnetic field dependencies. By use of calorimetry, M(T), and strain measurements, changes in M{sub s} up to -11 K/Tesla are observed. Such large values have, until now, not been observed in Heusler alloys. Since during transformation the volume changes reversibly, magnetic field-induced strains of about