WorldWideScience

Sample records for minimum dose prescribed

  1. The minimum measurable dose of the sensitive Harshaw TLDs

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1991-01-01

    The TL-dose response was measured for the sensitive Harshaw manufactured phosphors (CaF 2 :Dy and CaF 2 :Tm), taking chips from the same batch and from different batches. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses were derived and compared to the minimum measurable dose calculated by taking 3 times the standard deviation of unirradiated chips. The contribution of the individual calibration of each TLD chip was checked, as well

  2. Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gang, Ji Hyeong; Gim, Il Hwan; Hwang, Seon Boong; Kim, Woong; Im, Hyeong Seo; Gang, Jin Mook; Gim, Gi Hwan; Lee, Ah Ram [Dept. of Radiation Oncology, Korea Institute of Radiological and Medical Sciences, Seou (Korea, Republic of)

    2012-09-15

    The purpose of this study is to compare plans prescribed to point A with these prescribed to point H recommended by ABS (American Brachytherapy Society) in high dose rate intracavitary brachytherapy for cervical carcinoma. This study selected 103 patients who received HDR (High Dose Rate) brachytherapy using tandem and ovoids from March 2010 to January 2012. Point A, bladder point, and rectal point conform with Manchester System. Point H conforms with ABS recommendation. Also Sigmoid colon point, and vagina point were established arbitrarily. We examined distance between point A and point H. The percent dose at point A was calculated when 100% dose was prescribed to point H. Additionally, the percent dose at each reference points when dose is prescribed to point H and point A were calculated. The relative dose at point A was lower when point H was located inferior to point A. The relative doses at bladder, rectal, sigmoid colon, and vagina points were higher when point H was located superior to point A, and lower when point H was located inferior to point A. This study found out that as point H got located much superior to point A, the absorbed dose of surrounding normal organs became higher, and as point H got located much inferior to point A, the absorbed dose of surrounding normal organs became lower. This differences dose not seem to affect the treatment. However, we suggest this new point is worth being considered for the treatment of HDR if dose distribution and absorbed dose at normal organs have large differences between prescribed to point A and H.

  3. Compliance to the prescribed dose and overall treatment time in five randomized clinical trials of altered fractionation in radiotherapy for head-and-neck carcinomas

    International Nuclear Information System (INIS)

    Khalil, Azza A.; Bentzen, Soeren M.; Bernier, Jacques; Saunders, Michele I.; Horiot, Jean-Claude; Bogaert, Walter van den; Cummings, Bernard J.; Dische, Stanley

    2003-01-01

    Purpose: To investigate compliance to the prescribed dose-fractionation schedule in five randomized controlled trials of altered fractionation in radiotherapy for head-and-neck carcinoma. Methods and Materials: Individual patient data from 2566 patients participating in the European Organization for Research and Treatment of Cancer (EORTC) 22791, EORTC 22811, EORTC 22851, Princess Margaret Hospital (PMH), and continuous hyperfractionated accelerated radiotherapy (CHART) head-and-neck trials were merged in the fractionation IMPACT (Intergroup Merger of Patient data from Altered or Conventional Treatment schedules) study database. The ideal treatment time was defined as the minimum time required to deliver a prescribed schedule. Compliance to the prescribed overall treatment time was quantified as the difference between the actual and the ideal overall time. An overall measure of compliance in an individual patient, the total dose lost (TDL), was calculated as the dose lost due to prolongation of therapy (assuming a D prolif of 0.64 Gy/day) plus the difference between the prescribed and the actual dose given. Results: The time in excess of the ideal ranged up to 97 days (average 3.9 days), and 25% of the patients had delays of 6 days or more. World Health Organization (WHO) performance status and nodal stage had a significant effect on TDL. TDL was significantly higher in the conventional than in the altered arm of the EORTC 22851 and CHART trials. In the PMH trial, TDL was significantly higher in the hyperfractionation than in the conventional arm. Centers participating in the three EORTC trials varied significantly in their compliance. There was a significant improvement in compliance in patients treated more recently. Conclusions: Even in randomized controlled trials, compliance to the prescribed radiation therapy schedule may be relatively poor, especially after conventional fractionation. This affects the interpretation of the outcome of these trials

  4. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    Directory of Open Access Journals (Sweden)

    Kimberly Fernandes

    Full Text Available To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity.Interventional time-series analysis.Ontario, Canada, from 2003 to 2014.Ontario Drug Benefit (ODB beneficiaries aged 15 to 64 years from 2003 to 2014.Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010 and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011.Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions.Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03 which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43. Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7% over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68 or enactment of the NSAA (p-value = .59.Although the Canadian clinical practice guidelines for use of opioids in chronic non

  5. Prescribing psychotropic drugs to adults with an intellectual disability

    Science.gov (United States)

    Trollor, Julian N; Salomon, Carmela; Franklin, Catherine

    2016-01-01

    SUMMARY Mental illness is common in people with intellectual disability. They may also have physical health problems which can affect their mental state. Difficulties in communication can contribute to mental health problems being overlooked. These may present with changes in behaviour. Psychological management is usually preferable to prescribing psychotropic drugs. Behavioural approaches are the most appropriate way to manage challenging behaviour. If a drug is considered, prescribers should complete a thorough diagnostic assessment, exclude physical and environmental contributions to symptoms, and consider medical comorbidities before prescribing. Where possible avoid psychotropics with the highest cardiometabolic burden. Prescribe the minimum effective dose and treatment length, and regularly monitor drug efficacy and adverse effects. There is insufficient evidence to support the use of psychotropics for challenging behaviour. They should be avoided unless the behaviour is severe and non-responsive to other treatments. PMID:27756975

  6. Assessment of individual dose utilization vs. physician prescribing recommendations for recombinant activated factor VII (rFVIIa) in paediatric and adult patients with congenital haemophilia and alloantibody inhibitors (CHwI): the Dosing Observational Study in Hemophilia (DOSE).

    Science.gov (United States)

    Gruppo, R A; Kessler, C M; Neufeld, E J; Cooper, D L

    2013-07-01

    Recent data from the Dosing Observational Study in Hemophilia diary study has described home treatment with recombinant activated factor VII (rFVIIa) in congenital haemophilia with inhibitors (CHwI). The current analysis compares prescribed and patient/caregiver-reported rFVIIa administration in paediatric and adult CHwI patients in this study. Patients with ≥ 4 bleeding episodes within a 3-month period prescribed rFVIIa as first-line therapy for bleeding episodes were eligible. Patients/caregivers completed a diary for ≥ 90 days or until the patient experienced four bleeds. Initial, total and mean rFVIIa doses reported for each bleeding episode were calculated and compared with the physician-prescribed doses. Of 52 enrolled patients (25 children; 27 adults), 39 (75%) completed the study. Children and adults had similar mean durations of bleeding episodes. Both patient groups were administered higher initial rFVIIa doses for joint bleeds than prescribed: median (range) 215.2 (74.1-400.0) mcg kg(-1) vs. 200.0 (61.0-270.0) mcg kg(-1) for children, and 231.3 (59.3-379.7) mcg kg(-1) vs. 123.0 (81.0-289.0) mcg kg(-1) for adults. The median infused dose for joint bleeds was higher in adults than children (175.2 vs. 148.0 mcg kg(-1) ), but children received significantly more doses per joint bleed than adults (median 6.5 vs. 3.0). The median total dose per joint bleed was higher in children than adults (1248.7 vs. 441.6). For children and adults, both initial and additional doses administered for bleeds were higher than prescribed. Children received higher total doses per bleed due to an increased number of infusions per bleed. © 2013 John Wiley & Sons Ltd.

  7. Minimum dose method for walking-path planning of nuclear facilities

    International Nuclear Information System (INIS)

    Liu, Yong-kuo; Li, Meng-kun; Xie, Chun-li; Peng, Min-jun; Wang, Shuang-yu; Chao, Nan; Liu, Zhong-kun

    2015-01-01

    Highlights: • For radiation environment, the environment model is proposed. • For the least dose walking path problem, a path-planning method is designed. • The path-planning virtual–real mixed simulation program is developed. • The program can plan walking path and simulate. - Abstract: A minimum dose method based on staff walking road network model was proposed for the walking-path planning in nuclear facilities. A virtual–reality simulation program was developed using C# programming language and Direct X engine. The simulation program was used in simulations dealing with virtual nuclear facilities. Simulation results indicated that the walking-path planning method was effective in providing safety for people walking in nuclear facilities

  8. A step-up test procedure to find the minimum effective dose.

    Science.gov (United States)

    Wang, Weizhen; Peng, Jianan

    2015-01-01

    It is of great interest to find the minimum effective dose (MED) in dose-response studies. A sequence of decreasing null hypotheses to find the MED is formulated under the assumption of nondecreasing dose response means. A step-up multiple test procedure that controls the familywise error rate (FWER) is constructed based on the maximum likelihood estimators for the monotone normal means. When the MED is equal to one, the proposed test is uniformly more powerful than Hsu and Berger's test (1999). Also, a simulation study shows a substantial power improvement for the proposed test over four competitors. Three R-codes are provided in Supplemental Materials for this article. Go to the publishers online edition of Journal of Biopharmaceutical Statistics to view the files.

  9. Applicability of the minimum entropy generation method for optimizing thermodynamic cycles

    Institute of Scientific and Technical Information of China (English)

    Cheng Xue-Tao; Liang Xin-Gang

    2013-01-01

    Entropy generation is often used as a figure of merit in thermodynamic cycle optimizations.In this paper,it is shown that the applicability of the minimum entropy generation method to optimizing output power is conditional.The minimum entropy generation rate and the minimum entropy generation number do not correspond to the maximum output power when the total heat into the system of interest is not prescribed.For the cycles whose working medium is heated or cooled by streams with prescribed inlet temperatures and prescribed heat capacity flow rates,it is theoretically proved that both the minimum entropy generation rate and the minimum entropy generation number correspond to the maximum output power when the virtual entropy generation induced by dumping the used streams into the environment is considered.However,the minimum principle of entropy generation is not tenable in the case that the virtual entropy generation is not included,because the total heat into the system of interest is not fixed.An irreversible Carnot cycle and an irreversible Brayton cycle are analysed.The minimum entropy generation rate and the minimum entropy generation number do not correspond to the maximum output power if the heat into the system of interest is not prescribed.

  10. Applicability of the minimum entropy generation method for optimizing thermodynamic cycles

    International Nuclear Information System (INIS)

    Cheng Xue-Tao; Liang Xin-Gang

    2013-01-01

    Entropy generation is often used as a figure of merit in thermodynamic cycle optimizations. In this paper, it is shown that the applicability of the minimum entropy generation method to optimizing output power is conditional. The minimum entropy generation rate and the minimum entropy generation number do not correspond to the maximum output power when the total heat into the system of interest is not prescribed. For the cycles whose working medium is heated or cooled by streams with prescribed inlet temperatures and prescribed heat capacity flow rates, it is theoretically proved that both the minimum entropy generation rate and the minimum entropy generation number correspond to the maximum output power when the virtual entropy generation induced by dumping the used streams into the environment is considered. However, the minimum principle of entropy generation is not tenable in the case that the virtual entropy generation is not included, because the total heat into the system of interest is not fixed. An irreversible Carnot cycle and an irreversible Brayton cycle are analysed. The minimum entropy generation rate and the minimum entropy generation number do not correspond to the maximum output power if the heat into the system of interest is not prescribed. (general)

  11. Computational opioid prescribing: a novel application of clinical pharmacokinetics.

    Science.gov (United States)

    Linares, Oscar A; Linares, Annemarie L

    2011-01-01

    We implemented a pharmacokinetics-based mathematical modeling technique using algebra to assist prescribers with point-of-care opioid dosing. We call this technique computational opioid prescribing (COP). Because population pharmacokinetic parameter values are needed to estimate drug dosing regimen designs for individual patients using COP, and those values are not readily available to prescribers because they exist scattered in the vast pharmacology literature, we estimated the population pharmacokinetic parameter values for 12 commonly prescribed opioids from various sources using the bootstrap resampling technique. Our results show that opioid dosing regimen design, evaluation, and modification is feasible using COP. We conclude that COP is a new technique for the quantitative assessment of opioid dosing regimen design evaluation and adjustment, which may help prescribers to manage acute and chronic pain at the point-of-care. Potential benefits include opioid dose optimization and minimization of adverse opioid drug events, leading to potential improvement in patient treatment outcomes and safety.

  12. Minimum Benefits for HIV/AIDS in South African Medical Schemes ...

    African Journals Online (AJOL)

    ... to the Minister of Health in respect of the extent of prescribed minimum benefits for HIV/AIDS. Medical schemes are required to provide the PMBs to their members without limits or co-payments. Keywords: Medical schemes; HIV; AIDS; benefits; prescribed minimum benefits. South African Actuarial Journal: 2003 3: 77-112 ...

  13. Acute pain management: acetaminophen and ibuprofen are often under-dosed.

    Science.gov (United States)

    Milani, Gregorio P; Benini, Franca; Dell'Era, Laura; Silvagni, Davide; Podestà, Alberto F; Mancusi, Rossella Letizia; Fossali, Emilio F

    2017-07-01

    Most children with pain are managed by either acetaminophen or ibuprofen. However, no study has so far investigated if children are prescribed adequate doses of acetaminophen or ibuprofen in emergency department. Aim of this retrospective study was to investigate the prevalence of under-dosage of these drugs in children presenting with pain in emergency department. Children initially prescribed with acetaminophen or ibuprofen for pain management were included. The χ 2 automatic interaction detection method was used considering the percentage variation from the minimum of the appropriate dose as dependent variable while prescribed drug, age, gender, body weight, type of hospital (pediatric or general), and availability of internal guidelines on pediatric pain management in the emergency department as independent variables. Data on 1471 children managed for pain were available. Under-dosage was prescribed in 893 subjects (61%), of whom 577 were prescribed acetaminophen and 316 ibuprofen. The use of acetaminophen suppositories, body weight 40 kg, and the use of oral ibuprofen identified clusters of children associated with under-dosage prescription. Prescription of acetaminophen and ibuprofen was frequently under-dosed. The use of suppositories, lower and higher body weight, and the use of ibuprofen were associated with under-dosage. Under-dosing may reflect prescription of anti-pyretic doses. Agenzia Italiana del Farmaco-Observational Study Register (RSO). Registration code: PIERRE/1 What is Known: • Pain is frequent in children presented to emergency department. • International recommendations on pain management are often not implemented. What is New: • Acetaminophen and ibuprofen were frequently underdosed in children prescribed for pain in the Italian emergency departments. • Under-dosage may be related to the habit of using acetaminophen and ibuprofen in the recommended range for fever treatment.

  14. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Y; Yu, J; Xiao, Y [Thomas Jefferson University Hospital, Philadelphia, PA (United States)

    2015-06-15

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.

  15. SU-E-T-578: On Definition of Minimum and Maximum Dose for Target Volume

    International Nuclear Information System (INIS)

    Gong, Y; Yu, J; Xiao, Y

    2015-01-01

    Purpose: This study aims to investigate the impact of different minimum and maximum dose definitions in radiotherapy treatment plan quality evaluation criteria by using tumor control probability (TCP) models. Methods: Dosimetric criteria used in RTOG 1308 protocol are used in the investigation. RTOG 1308 is a phase III randomized trial comparing overall survival after photon versus proton chemoradiotherapy for inoperable stage II-IIIB NSCLC. The prescription dose for planning target volume (PTV) is 70Gy. Maximum dose (Dmax) should not exceed 84Gy and minimum dose (Dmin) should not go below 59.5Gy in order for the plan to be “per protocol” (satisfactory).A mathematical model that simulates the characteristics of PTV dose volume histogram (DVH) curve with normalized volume is built. The Dmax and Dmin are noted as percentage volumes Dη% and D(100-δ)%, with η and d ranging from 0 to 3.5. The model includes three straight line sections and goes through four points: D95%= 70Gy, Dη%= 84Gy, D(100-δ)%= 59.5 Gy, and D100%= 0Gy. For each set of η and δ, the TCP value is calculated using the inhomogeneously irradiated tumor logistic model with D50= 74.5Gy and γ50=3.52. Results: TCP varies within 0.9% with η; and δ values between 0 and 1. With η and η varies between 0 and 2, TCP change was up to 2.4%. With η and δ variations from 0 to 3.5, maximum of 8.3% TCP difference is seen. Conclusion: When defined maximum and minimum volume varied more than 2%, significant TCP variations were seen. It is recommended less than 2% volume used in definition of Dmax or Dmin for target dosimetric evaluation criteria. This project was supported by NIH grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant

  16. Dose evaluation of TPS according to treatment sites in IMRT

    International Nuclear Information System (INIS)

    Kim, Jin Man; Kim, Jong Sik; Hong, Chae Seon; Park, Ju Young; Park, Su Yeon; Ju, Sang Gyu

    2013-01-01

    This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as Pinnacle 3 (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made

  17. Benchmarking the minimum Electron Beam (eBeam) dose required for the sterilization of space foods

    Science.gov (United States)

    Bhatia, Sohini S.; Wall, Kayley R.; Kerth, Chris R.; Pillai, Suresh D.

    2018-02-01

    As manned space missions extend in length, the safety, nutrition, acceptability, and shelf life of space foods are of paramount importance to NASA. Since food and mealtimes play a key role in reducing stress and boredom of prolonged missions, the quality of food in terms of appearance, flavor, texture, and aroma can have significant psychological ramifications on astronaut performance. The FDA, which oversees space foods, currently requires a minimum dose of 44 kGy for irradiated space foods. The underlying hypothesis was that commercial sterility of space foods could be achieved at a significantly lower dose, and this lowered dose would positively affect the shelf life of the product. Electron beam processed beef fajitas were used as an example NASA space food to benchmark the minimum eBeam dose required for sterility. A 15 kGy dose was able to achieve an approximately 10 log reduction in Shiga-toxin-producing Escherichia coli bacteria, and a 5 log reduction in Clostridium sporogenes spores. Furthermore, accelerated shelf life testing (ASLT) to determine sensory and quality characteristics under various conditions was conducted. Using Multidimensional gas-chromatography-olfactometry-mass spectrometry (MDGC-O-MS), numerous volatiles were shown to be dependent on the dose applied to the product. Furthermore, concentrations of off -flavor aroma compounds such as dimethyl sulfide were decreased at the reduced 15 kGy dose. The results suggest that the combination of conventional cooking combined with eBeam processing (15 kGy) can achieve the safety and shelf-life objectives needed for long duration space-foods.

  18. Fixed-dose combinations at the front line of multimodal pain management: perspective of the nurse-prescriber

    Directory of Open Access Journals (Sweden)

    O'Brien J

    2013-02-01

    Full Text Available Joanne O’Brien,1 Joseph V Pergolizzi Jr,2 Mart van de Laar3, Hans-Ulrich Mellinghoff,4 Ignacio Morón Merchante,5 Srinivas Nalamachu,6 Serge Perrot,7 Robert B Raffa81Department of Pain Medicine, Beaumont Hospital, Beaumont, Dublin, Ireland; 2Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD; Association of Chronic Pain Patients, Houston, TX; Department of Pharmacology, Temple University School of Medicine, Philadelphia, PA, USA; 3Arthritis Center Twente, Enschede, The Netherlands; 4Department of Endocrinology, Diabetology and Osteology, Kantonsspital St Gallen, Switzerland; 5Centro de Salud Universitario Goya, Madrid, Spain; 6Kansas University Medical Center, Kansas City, and International Clinic Research, Leawood, KS, USA; 7Service de Médecine Interne et Consultation de la Douleur, Hôpital Hotel Dieu, Paris Descartes University, Paris, France; 8Department of Pharmaceutical Sciences, Temple University School of Pharmacy, Philadelphia PA, USAAbstract: Pain should be treated promptly and effectively to restore the patient to full function, avoid pain chronification, and preserve quality of life. A recent pain specialists' meeting discussed the use of different pharmacological treatment options, such as topical analgesics, nonopioid agents (such as paracetamol and nonsteroidal anti-inflammatory drugs, weak and strong opioids, and fixed-dose combination products in the management of moderate to severe pain from different etiologies. One of the topics discussed in, and subsequent to, this meeting was the role of fixed-dose combination products for nurse-prescribers who are in many ways at the front line of managing both acute and chronic pain syndromes. The panel agreed that proper product selection should take into account the patient's age, condition, type of pain, and comorbidities, as well as balance safety with effectiveness. Although nurse-prescribers need to be aware of cumulative paracetamol dosing, fixed-dose

  19. Drug Dosing in Patients with Renal Insufficiency in a Hospital Setting using Electronic Prescribing and Automated Reporting of Estimated Glomerular Filtration Rate

    DEFF Research Database (Denmark)

    Nielsen, Anita L.; Henriksen, Daniel Pilsgaard; Marinakis, Christianna

    2014-01-01

    In patients with impaired renal function, drug dose adjustment is often required. Non-adherence to clinical prescribing recommendations may result in severe adverse events. In previous studies, the prevalence rate of non-adherence to recommended dosing has been reported to be 19-67%. Using the cl...... decision support systems should be explored. This article is protected by copyright. All rights reserved....

  20. Prescribing and evaluating target dose in dose-painting treatment plans

    DEFF Research Database (Denmark)

    Håkansson, Katrin; Specht, Lena; Aznar, Marianne C

    2014-01-01

    BACKGROUND: Assessment of target dose conformity in multi-dose-level treatment plans is challenging due to inevitable over/underdosage at the border zone between dose levels. Here, we evaluate different target dose prescription planning aims and approaches to evaluate the relative merit of such p......-painting and multi-dose-level plans. The tool can be useful for quality assurance of multi-center trials, and for visualizing the development of treatment planning in routine clinical practice....... of such plans. A quality volume histogram (QVH) tool for history-based evaluation is proposed. MATERIAL AND METHODS: Twenty head and neck cancer dose-painting plans with five prescription levels were evaluated, as well as clinically delivered simultaneous integrated boost (SIB) plans from 2010 and 2012. The QVH...

  1. Dosing strategy based on prevailing aminoglycoside minimum inhibitory concentration in India: Evidence and issues

    Directory of Open Access Journals (Sweden)

    Balaji Veeraraghavan

    2017-01-01

    Full Text Available Aminoglycosides are important agents used for treating drug-resistant infections. The current dosing regimen of aminoglycosides does not achieve sufficient serum level concentration for the infected bacterial pathogen interpreted as susceptible based on laboratory testing. Minimum inhibitory concentration was determined for nearly 2000 isolates of Enterobacteriaceae and Pseudomonas aeruginosa by broth microdilution method. Results were interpreted based on CLSI and EUCAST interpretative criteria and the inconsistencies in the susceptibility profile were noted. This study provides insights into the inconsistencies existing in the laboratory interpretation and the corresponding clinical success rates. This urges the need for revising clinical breakpoints for amikacin, to resolve under dosing leading to clinical failure.

  2. SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

    International Nuclear Information System (INIS)

    Winslow, J; Hurwitz, L; Christianson, O; Samei, E

    2014-01-01

    Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose

  3. Cosmic Ray Modulation and Radiation Dose of Aircrews During Possible Grand Minimum

    Science.gov (United States)

    Miyake, S.; Kataoka, R.; Sato, T.; Imada, S.; Miyahara, H.; Shiota, D.; Matsumoto, T.; Ueno, H.

    2017-12-01

    The Sun is exhibiting low solar activity levels since the descending phase of the last solar cycle, and it is likely to be continued as well as in the case of the past grand solar minima. The cosmic-ray modulation, which is the variation of the galactic cosmic ray (GCR) spectrum caused by the heliospheric environmental change, is basically anti-correlated with the solar activity. In the recent weak solar cycle, we thus expect that the flux of GCRs is getting higher than that in the previous solar cycles, leading to the increase in the radiation exposure in the space and atmosphere. In order to quantitatively evaluate the possible solar modulation of GCRs and resultant radiation exposure at flight altitude, we have developed the time-dependent and three-dimensional model of the cosmic-ray modulation. Our model can give the flux of GCRs anywhere in the heliosphere by assuming the variation of the solar wind speed, the strength of the heliospheric magnetic field (HMF), and its tilt angle. We solve the gradient-curvature drift motion of GCRs in the HMF, and therefore reproduce the 22-year variation of the cosmic-ray modulation. We also calculate the neutron monitor counting rate and the radiation dose of aircrews at flight altitude, by the air-shower simulation performed by PHITS (Particle and Heavy Ion Transport code System). In our previous study [1], we calculated the radiation dose at a flight altitude during the coming solar cycle by assuming the variation of the solar wind speed and the strength of the HMF expressed by sinusoidal curve, and obtained that an annual radiation dose of aircrews in 5 years around the next solar minimum will be up to 19% higher than that at the last cycle. In this study, we predict the new model of the heliospheric environmental change on the basis of a prediction model for the sunspot number. The quantitative predictions of the cosmic-ray modulation and the radiation dose at a flight altitude during possible Grand Minimum considering

  4. Incase of Same Region Treatment by using a Tomotherapy and a Linear Accelerator Absorbed Dose Evaluation of Normal Tissues and a Tumor

    International Nuclear Information System (INIS)

    Cheon, Geum Seong; Kim, Chang Uk; Kim, Hoi Nam; Heo, Gyeong Hun; Song, Jin Ho; Hong, Joo Yeong; Jeong, Jae Yong

    2010-01-01

    Treating same region with different modalities there is a limit to evaluate the total absorbed dose of normal tissues. The reason is that it does not support to communication each modalities yet. In this article, it evaluates absorbed dose of the patients who had been treated same region by a tomotherapy and a linear accelerator. After reconstructing anatomic structure with a anthropomorphic phantom, administrate 45 Gy to a tumor in linac plan system as well as prescribe 15 Gy in tomotherapy plan system for make an ideal treatment plan. After the plan which made by tomoplan system transfers to the oncentra plan system for reproduce plan under the same condition and realize total treatment plan with summation 45 Gy linac treatment plan. To evaluate the absorbed dose of two different modalities, do a comparative study both a simple summation dose values and integration dose values. Then compare and analyze absorbed dose of normal tissues and a tumor with the patients who had been exposured radiation by above two different modalities. The result of compared data, in case of minimum dose, there are big different dose values in spleen (12.4%). On the other hand, in case of the maximum dose, it reports big different in a small bowel (10.2%) and a cord (5.8%) in head and neck cancer patients, there presents that oral (20.3%), right lens (7.7%) in minimum dose value. About maximum dose, it represents that spinal (22.5), brain stem (12%), optic chiasm (8.9%), Rt lens (11.5%), mandible (8.1%), pituitary gland (6.2%). In case of Rt abdominal cancer patients, there represents big different minimum dose as Lt kidney (20.3%), stomach (8.1%) about pelvic cancer patients, it reports there are big different in minimum dose as a bladder (15.2%) as well as big different value in maximum dose as a small bowel (5.6%), a bladder (5.5%) in addition, making treatment plan it is able us to get. In case of comparing both simple summation absorbed dose and integration absorbed dose, the

  5. Analysis of the relationship between tumor dose inhomogeneity and local control in patients with skull base chordoma

    International Nuclear Information System (INIS)

    Terahara, Atsuro; Niemierko, Andrzej; Goitein, Michael; Finkelstein, Dianne; Hug, Eugen; Liebsch, Norbert; O'Farrell, Desmond; Lyons, Sue; Munzenrider, John

    1999-01-01

    Purpose: When irradiating a tumor that abuts or displaces any normal structures, the dose constraints to those structures (if lower than the prescribed dose) may cause dose inhomogeneity in the tumor volume at the tumor-critical structure interface. The low-dose region in the tumor volume may be one of the reasons for local failure. The aim of this study is to quantitate the effect of tumor dose inhomogeneity on local control and recurrence-free survival in patients with skull base chordoma. Methods and Materials: 132 patients with skull base chordoma were treated with combined photon and proton irradiation between 1978 and 1993. This study reviews 115 patients whose dose-volume data and follow-up data are available. The prescribed doses ranged from 66.6 Cobalt-Gray-Equivalent (CGE) to 79.2 CGE (median of 68.9 CGE). The dose to the optic structures (optic nerves and chiasma), the brain stem surface, and the brain stem center was limited to 60, 64, and 53 CGE, respectively. We used the dose-volume histogram data derived with the three-dimensional treatment planning system to evaluate several dose-volume parameters including the Equivalent Uniform Dose (EUD). We also analyzed several other patient and treatment factors in relation to local control and recurrence-free survival. Results: Local failure developed in 42 of 115 patients, with the actuarial local control rates at 5 and 10 years being 59% and 44%. Gender was a significant predictor for local control with the prognosis in males being significantly better than that in females (P 0.004, hazard ratio = 2.3). In a Cox univariate analysis, with stratification by gender, the significant predictors for local control (at the probability level of 0.05) were EUD, the target volume, the minimum dose, and the D 5cc dose. The prescribed dose, histology, age, the maximum dose, the mean dose, the median dose, the D 90% dose, and the overall treatment time were not significant factors. In a Cox multivariate analysis, the

  6. Assessment of antibiotic prescribing in Latvian general practitioners

    Directory of Open Access Journals (Sweden)

    Dumpis Uga

    2013-01-01

    Full Text Available Abstract Background Though general antibiotic consumption data is available, information on the actual patterns of prescribing antibiotics locally is difficult to obtain. An easy to use methodology was designed to assess ambulatory management of infections by Latvian general practitioners (GPs. Methods GPs were asked to record data in a patient data collection form for every patient that received antibiotics. Study period – (7 days one week in November, 2008. Data recorded included the following details: an antibiotic, the prescribed dose, dosing interval, route of administration combined with the demographic factors of the patient and clinical diagnosis based on a pre-defined list. Results Two hundred forty eight forms out of the 600 (41% were returned by post. Antibiotics were prescribed in 6.4% (1711/26803 of outpatient consultations. In total, 1763 antibiotics were prescribed during the study period. Ninety seven percent of the patients received monotherapy and only 47 (2.7% patients were prescribed two antibiotics. The most commonly prescribed antibiotics were amoxicillin (33.9% of prescribed, amoxicillin/clavulanate (18,7% and clarithromycin (7.6%. The most commonly treated indications were pharyngitis (29.8%, acute bronchitis (25.3% and rhinosinusitis (10.2%. Pneumonia was mostly treated with amoxicillin/clavulanate (25,7%, amoxicillin (15.7% and clarithromycin (19.3%. Conclusions Methodology employed provided useful additional information on ambulatory practice of prescribing antibiotics and could be used in further assessment studies. Educational interventions should be focused on treatment of acute pharyngitis and bronchitis in children and unnecessary use of quinolones in adults for uncomplicated urinary tract infection.

  7. Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Ding, George X.; Duggan, Dennis M.; Lu Bo; Hallahan, Dennis E.; Cmelak, Anthony; Malcolm, Arnold; Newton, Jared; Deeley, Matthew; Coffey, Charles W.

    2007-01-01

    The purpose of this study is to assess the real target dose coverage when radiation treatments were delivered to lung cancer patients based on treatment planning according to the RTOG-0236 Protocol. We compare calculated dosimetric results between the more accurate anisotropic analytical algorithm (AAA) and the pencil beam algorithm for stereotactic body radiation therapy treatment planning in lung cancer. Ten patients with non-small cell lung cancer were given 60 Gy in three fractions using 6 and 10 MV beams with 8-10 fields. The patients were chosen in accordance with the lung RTOG-0236 protocol. The dose calculations were performed using the pencil beam algorithm with no heterogeneity corrections (PB-NC) and then recalculated with the pencil beam with modified Batho heterogeneity corrections (PB-MB) and the AAA using an identical beam setup and monitor units. The differences in calculated dose to 95% or 99% of the PTV, between using the PB-NC and the AAA, were within 10% of prescribed dose (60 Gy). However, the minimum dose to 95% and 99% of PTV calculated using the PB-MB were consistently overestimated by up to 40% and 36% of the prescribed dose, respectively, compared to that calculated by the AAA. Using the AAA as reference, the calculated maximum doses were underestimated by up to 27% using the PB-NC and overestimated by 19% using the PB-MB. The calculations of dose to lung from PB-NC generally agree with that of AAA except in the small high-dose region where PB-NC underestimates. The calculated dose distributions near the interface using the AAA agree with those from Monte Carlo calculations as well as measured values. This study indicates that the real minimum PTV dose coverage cannot be guaranteed when the PB-NC is used to calculate the monitor unit settings in dose prescriptions

  8. 29 CFR 783.26 - The section 6(b)(2) minimum wage requirement.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false The section 6(b)(2) minimum wage requirement. 783.26... The section 6(b)(2) minimum wage requirement. Section 6(b), with paragraph (2) thereof, requires the... prescribed by” paragraph (1) of the subsection is the minimum wage rate applicable according to the schedule...

  9. Review on patients radiation dose and frequency of procedures during medical exposure in Sudan

    International Nuclear Information System (INIS)

    Abu Baker, Samah Mohamed Nasr

    2015-09-01

    The aim of this study was to estimate patient dose, the annual frequency and the number of staff and devices in the medical applications of ionizing radiation in Sudan. Survey was conducted on diagnostic radiology, nuclear medicine and radiotherapy. With respect to diagnostic radiology, only patient radiation dose was estimated. The data for diagnostic radiology was obtained from 24 peer reviewed scientific published literatures during the years ( 2006 - 2015). The collected publications included about 64 Sudanese hospitals covering different types of diagnostic exams. A values of the effective dose for pediatrics and adult patients were within the ranges of similar worldwide values published by UNSCEAR report in 2008 with exceptional to fluoroscopy hysterosalpingography for adult patients. For nuclear medicine procedures, questionnaires were distributed to five hospitals representing the whole existing NM department in Sudan at the time of of study. The estimated total annual frequency of diagnostic procedures was 0.2 per 1000 population. The estimated total annual collective and annual per caput effective dose from all NM procedures were 16.268 man Sv and 0.5 μSv, respectively. Comparing the annual per caput effective dose with UNSCEAR value our results was less than the worldwide value and greater than the value for heath care level 111-1 v countries. Questionnaires were also distributed to collect data on radiotherapy procedures performed in the two existing radioisotopes Sudanese hospitals. The prescribed dose and the number of fractions were comparable between the two hospitals. The minimum prescribed dose was 20 Gy with 5 fractions for nasopharynx (NPH) palliative and the maximum prescribed dose was 64 Gy with 32 fractions for prostate.(Author)

  10. Preliminary estimation of minimum target dose in intracavitary radiotherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Oishi-Tanaka, Yumiko; Sugahara, Shinji; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2001-08-01

    In intracavitary radiotherapy (ICRT) for cervical cancer, minimum target dose (D{sub min}) will pertain to local disease control more directly than will reference point A dose (D{sub A}). However, ICRT has been performed traditionally without specifying D{sub min} since the target volume was not identified. We have estimated D{sub min} retrospectively by identifying tumors using magnetic resonance (MR) images. Pre- and posttreatment MR images of 31 patients treated with high-dose-rate ICRT were used. ICRT was performed once weekly at 6.0 Gy D{sub A}, and involved 2-5 insertions for each patient, 119 insertions in total. D{sub min} was calculated arbitrarily simply at the point A level using the tumor width (W{sub A}) to compare with D{sub A}. W{sub A} at each insertion was estimated by regression analysis with pre- and posttreatment W{sub A}. D{sub min} for each insertion varied from 3.0 to 46.0 Gy, a 16-fold difference. The ratio of total D{sub min} to total D{sub A} for each patient varied from 0.5 to 6.5. Intrapatient D{sub min} difference between the initial insertion and final insertion varied from 1.1 to 3.4. Preliminary estimation revealed that D{sub min} varies widely under generic dose prescription. Thorough D{sub min} specification will be realized when ICRT-applicator insertion is performed under MR imaging. (author)

  11. Antiepileptic drug prescribing before, during and after pregnancy

    DEFF Research Database (Denmark)

    Charlton, Rachel; Garne, Ester; Wang, Hao

    2015-01-01

    and after pregnancy were identified in each of the databases. AED prescribing patterns were analysed, and the choice of AEDs and co-prescribing of folic acid were evaluated. Results In total, 978 957 women with 1 248 713 deliveries were identified. In all regions, AED prescribing declined during pregnancy...... co-prescribed with high-dose folic acid: ranging from 1.0% (CI950.3–1.8%) in Emilia Romagna to 33.5% (CI9528.7–38.4%) in Wales. Conclusion The country's differences in prescribing patterns may suggest different use, knowledge or interpretation of the scientific evidence base. The low co......-prescribing of folic acid indicates that more needs to be done to better inform clinicians and women of childbearing age taking AEDs about the need to offer and receive complete preconception care....

  12. A drug utilisation study investigating prescribed daily doses of ...

    African Journals Online (AJOL)

    and drug groups. Design. Retrospective drug utilisation study using data .... drugs that were prescribed 20 or fewer times during the period under ... occurs in women and men at different ages and with different severity. group. On average, men ...

  13. Skull base chordomas: analysis of dose-response characteristics

    International Nuclear Information System (INIS)

    Niemierko, Andrzej; Terahara, Atsuro; Goitein, Michael

    1997-01-01

    Objective: To extract dose-response characteristics from dose-volume histograms and corresponding actuarial survival statistics for 115 patients with skull base chordomas. Materials and Methods: We analyzed data for 115 patients with skull base chordoma treated with combined photon and proton conformal radiotherapy to doses in the range 66.6Gy - 79.2Gy. Data set for each patient included gender, histology, age, tumor volume, prescribed dose, overall treatment time, time to recurrence or time to last observation, target dose-volume histogram, and several dosimetric parameters (minimum/mean/median/maximum target dose, percent of the target volume receiving the prescribed dose, dose to 90% of the target volume, and the Equivalent Uniform Dose (EUD). Data were analyzed using the Kaplan-Meier survivor function estimate, the proportional hazards (Cox) model, and parametric modeling of the actuarial probability of recurrence. Parameters of dose-response characteristics were obtained using the maximum likelihood method. Results: Local failure developed in 42 (36%) of patients, with actuarial local control rates at 5 years of 59.2%. The proportional hazards model revealed significant dependence of gender on the probability of recurrence, with female patients having significantly poorer prognosis (hazard ratio of 2.3 with the p value of 0.008). The Wilcoxon and the log-rank tests of the corresponding Kaplan-Meier recurrence-free survival curves confirmed statistical significance of this effect. The Cox model with stratification by gender showed significance of tumor volume (p=0.01), the minimum target dose (p=0.02), and the EUD (p=0.02). Other parameters were not significant at the α level of significance of 0.05, including the prescribed dose (p=0.21). Parametric analysis using a combined model of tumor control probability (to account for non-uniformity of target dose distribution) and the Weibull failure time model (to account for censoring) allowed us to estimate

  14. SU-F-T-35: Optimization of Bladder and Rectal Doses Using a Multi-Lumen Intracavitary Applicator for Gynecological Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Laoui, S; Dietrich, S; Sehgal, V; Al-Ghazi, M [University of California, Irvine, Orange, CA (United States)

    2016-06-15

    Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, one central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.

  15. High dose per fraction dosimetry of small fields with Gafchromic EBT2 film

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Basavatia, Amar; Bayliss, Adam; Tome, Wolfgang A.

    2011-01-01

    Purpose: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. Methods: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. Results: The measured target doses and isodose coverage agreed with the planned dose within ±1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. Conclusions: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.

  16. Dose received by radiation workers in Australia, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Morris, N D

    1994-07-01

    Exposure to radiation can cause genetic defects or cancer. People who use sources of radiation as part of their employment are potentially at a greater risk than others owing to the possibility of their being continually exposed to small radiation doses over a long period. In Australia, the National Health and Medical Research Council has established radiation protection standards and set annual effective dose limits for radiation workers in order to minimise the chance of adverse effects occurring. These standards are based on the the recommendations of the International Commission on Radiological Protection (ICRP 1990). In order to ensure that the prescribed limits are not exceeded and to ensure that doses are kept to a minimum, some sort of monitoring is necessary. The primary purpose of this report is to provide data on the distribution of effective doses for different occupational categories of radiation worker in Australia. The total collective effective dose was found to be of the order of 4.9 Sv for a total of 34750 workers. 9 refs., 16 tabs., 6 figs.

  17. Dose received by radiation workers in Australia, 1991

    International Nuclear Information System (INIS)

    Morris, N.D.

    1994-07-01

    Exposure to radiation can cause genetic defects or cancer. People who use sources of radiation as part of their employment are potentially at a greater risk than others owing to the possibility of their being continually exposed to small radiation doses over a long period. In Australia, the National Health and Medical Research Council has established radiation protection standards and set annual effective dose limits for radiation workers in order to minimise the chance of adverse effects occurring. These standards are based on the the recommendations of the International Commission on Radiological Protection (ICRP 1990). In order to ensure that the prescribed limits are not exceeded and to ensure that doses are kept to a minimum, some sort of monitoring is necessary. The primary purpose of this report is to provide data on the distribution of effective doses for different occupational categories of radiation worker in Australia. The total collective effective dose was found to be of the order of 4.9 Sv for a total of 34750 workers. 9 refs., 16 tabs., 6 figs

  18. 48 CFR 852.219-9 - VA Small business subcontracting plan minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false VA Small business... Provisions and Clauses 852.219-9 VA Small business subcontracting plan minimum requirements. As prescribed in subpart 819.709, insert the following clause: VA Small Business Subcontracting Plan Minimum Requirements...

  19. Effects of Minimum and Maximum Doses of Furosemide on Fractional Shortening Parameter in Echocardiography of the New Zealand White Rabbit

    Directory of Open Access Journals (Sweden)

    Roham Vali, Mohammad Nasrollahzadeh Masouleh* and Siamak Mashhady Rafie1

    2013-04-01

    Full Text Available There is no data on the effect of maximum and minimum doses of furosemide on heart's work performance and amount of fractional shortening (FS in echocardiography of rabbit. This study was designed to validate probability of the mentionable effect. Twenty-four healthy female New Zealand white rabbits were divided into four equal groups. Maximum and minimum doses of furosemide were used for the first and second groups and the injection solution for the third and fourth groups was sodium chloride 0.9% which had the same calculated volumes of furosemide for the first two groups, respectively. The left ventricle FS in statutory times (0, 2, 5, 15, 30 minutes was determined by echocardiography. Measurements of Mean±SD, maximum and minimum amounts for FS values in all groups before injection and in statutory times were calculated. Statistical analysis revealed non-significant correlation between the means of FS. The results of this study showed that furosemide can be used as a diuretic agent for preparing a window approach in abdominal ultrasonography examination with no harmful effect on cardiac function.

  20. Prescribing Patterns of Intravenous Golimumab for Rheumatoid Arthritis.

    Science.gov (United States)

    Brady, Brenna L; Tkacz, Joseph P; Lofland, Jennifer; Meyer, Roxanne; Bolge, Susan C

    2015-09-01

    The use of intravenous golimumab (GLM-IV), in combination with methotrexate, was approved by the US Food and Drug Administration in July 2013 for the treatment of moderate to severe, active rheumatoid arthritis (RA). GLM-IV is available in 50-mg vials, and the prescribing information specifies a dosing regimen of 2 mg/kg at 0 and 4 weeks and then every 8 weeks thereafter. The purpose of this study was to examine the patterns of prescribing and administration of GLM-IV, including the demographic, clinical, and utilization characteristics of patients with RA newly treated with GLM-IV. Rheumatology practices across the continental United States were solicited for a chart-review study. Inclusion criteria were: (1) diagnosis of RA; (2) current treatment with GLM-IV; (3) age ≥18 years; and (4) lack of pregnancy (in female patients). Physicians were offered a monetary incentive for each eligible chart provided. An electronic case-report form was developed to aid in the chart data extraction and included fields for demographic characteristics, available comorbid diagnoses, prior RA treatments, and doses and dates of GLM-IV administration. A total of 117 eligible patient charts from 15 rheumatologist practices were reviewed. The patient sample was predominantly female (81.2%), with a mean (SD) age of 55.4 (14.5) years. A total of 55.6% of patients had evidence of biologic treatment before receiving GLM-IV, and 53% had at least 1 comorbid condition. In total, 300 individual GLM-IV infusions from this sample were reviewed. Due to the relatively recent approval of GLM-IV use by the US Food and Drug Administration, the majority of patients in this sample (69.2%) had received only between 2 and 4 infusions at the time of the review. For infusion records with valid dose data, the mean number of administered vials was 3.6 (0.8) (total dose, 180 mg); the majority of patients received a dose consistent with the prescribed dose of 2 mg/kg. Combination therapy with methotrexate was

  1. Medication errors: prescribing faults and prescription errors.

    Science.gov (United States)

    Velo, Giampaolo P; Minuz, Pietro

    2009-06-01

    1. Medication errors are common in general practice and in hospitals. Both errors in the act of writing (prescription errors) and prescribing faults due to erroneous medical decisions can result in harm to patients. 2. Any step in the prescribing process can generate errors. Slips, lapses, or mistakes are sources of errors, as in unintended omissions in the transcription of drugs. Faults in dose selection, omitted transcription, and poor handwriting are common. 3. Inadequate knowledge or competence and incomplete information about clinical characteristics and previous treatment of individual patients can result in prescribing faults, including the use of potentially inappropriate medications. 4. An unsafe working environment, complex or undefined procedures, and inadequate communication among health-care personnel, particularly between doctors and nurses, have been identified as important underlying factors that contribute to prescription errors and prescribing faults. 5. Active interventions aimed at reducing prescription errors and prescribing faults are strongly recommended. These should be focused on the education and training of prescribers and the use of on-line aids. The complexity of the prescribing procedure should be reduced by introducing automated systems or uniform prescribing charts, in order to avoid transcription and omission errors. Feedback control systems and immediate review of prescriptions, which can be performed with the assistance of a hospital pharmacist, are also helpful. Audits should be performed periodically.

  2. What is the optimum minimum segment size used in step and shoot IMRT for prostate cancer?

    International Nuclear Information System (INIS)

    Takahashi, Yutaka; Sumida, Iori; Koizumi, Masahiko

    2010-01-01

    Although the use of small segments in step and shoot intensity modulated radiation therapy (IMRT) provides better dose distribution, extremely small segments decrease treatment accuracy. The purpose of this study was to determine the optimum minimum segment size (MSS) in two-step optimization in prostate step and shoot IMRT with regard to both planning quality and dosimetric accuracy. The XiO treatment planning system and Oncor Impression Plus were used. Results showed that the difference in homogeneity index (HI), defined as the ratio of maximum to minimum doses for planning target volume, between the MSS 1.0 cm and 1.5 cm plans, and 2.0 cm plans, was 0.1%, and 9.6%, respectively. With regard to V107 of planning target volume (PTV), the volume receiving 107% of the prescribed dose of the PTV, the difference between MSS 1.0 cm and 1.5 cm was 2%. However, the value of the MSS 2.0 cm or greater plans was more than 2.5-fold that of the MSS 1.0 cm plan. With regard to maximum rectal dose, a significant difference was seen between the MSS 1.5 cm and 2.0 cm plans, whereas no significant difference was seen between the MSS 1.0 cm and 1.5 cm plans. Composite plan verification revealed a greater than 5% dose difference between planned and measured dose in many regions with the MSS 1.0 cm plan, but in only limited regions in the MSS 1.5 cm plan. Our data suggest that the MSS should be determined with regard to both planning quality and dosimetric accuracy. (author)

  3. Opioid-prescribing practices in chronic cancer pain in a tertiary care pain clinic

    Directory of Open Access Journals (Sweden)

    Raghu S Thota

    2011-01-01

    Full Text Available Introduction: Under treatment of pain is a recognized global issue. Opioid analgesic medication is the mainstay of treatment in cancer patients as per the World Health Organization (WHO pain relief ladder, yet 50% of cancer patients worldwide do not receive adequate pain relief or are undertreated. Aim: The aim of this study was to audit the ongoing opioid-prescribing practices in our tertiary cancer pain clinic during January-June 2010. Materials& Methods: The prescribed type of opioid, dose, dosing interval, and laxatives details were analyzed. Results: Five hundred pain files were reviewed and 435 were found complete for audit. Three hundred forty-eight (80% patients were prescribed opioids. Two hundred fifty-nine (74.4% received weak opioids while 118 (33.9% received strong opioids. A total of 195 (45% patients had moderate and 184 (42% had severe pain. Ninety-three (26.7% patients received morphine; however, only 31.5% (58 of 184 in severe pain received morphine as per the WHO pain ladder. Only 73 of 93 (78.4% patients received an adequate dose of morphine with an adequate dosing interval and only 27 (29% were prescribed laxatives with morphine. Conclusion: This study shows that the under treatment of pain and under dosing of opioids coupled with improper side effect management are major issues.

  4. Electronic prescribing reduces prescribing error in public hospitals.

    Science.gov (United States)

    Shawahna, Ramzi; Rahman, Nisar-Ur; Ahmad, Mahmood; Debray, Marcel; Yliperttula, Marjo; Declèves, Xavier

    2011-11-01

    To examine the incidence of prescribing errors in a main public hospital in Pakistan and to assess the impact of introducing electronic prescribing system on the reduction of their incidence. Medication errors are persistent in today's healthcare system. The impact of electronic prescribing on reducing errors has not been tested in developing world. Prospective review of medication and discharge medication charts before and after the introduction of an electronic inpatient record and prescribing system. Inpatient records (n = 3300) and 1100 discharge medication sheets were reviewed for prescribing errors before and after the installation of electronic prescribing system in 11 wards. Medications (13,328 and 14,064) were prescribed for inpatients, among which 3008 and 1147 prescribing errors were identified, giving an overall error rate of 22·6% and 8·2% throughout paper-based and electronic prescribing, respectively. Medications (2480 and 2790) were prescribed for discharge patients, among which 418 and 123 errors were detected, giving an overall error rate of 16·9% and 4·4% during paper-based and electronic prescribing, respectively. Electronic prescribing has a significant effect on the reduction of prescribing errors. Prescribing errors are commonplace in Pakistan public hospitals. The study evaluated the impact of introducing electronic inpatient records and electronic prescribing in the reduction of prescribing errors in a public hospital in Pakistan. © 2011 Blackwell Publishing Ltd.

  5. The safety of meperidine prescribing in older adults: A longitudinal population-based study.

    Science.gov (United States)

    Friesen, Kevin J; Falk, Jamie; Bugden, Shawn

    2016-05-11

    Meperidine (pethidine) is an opioid analgesic that offers little advantage relative to other opioids and several disadvantages including limited potency, short duration of action, and the production of a neurotoxic metabolite (normeperidine) with a long half-life. Older adults are more sensitive to meperidine's side effects and may have diminished renal function which leads to the accumulation of normeperidine. The Institute for Safe Medication Practices has suggested avoiding meperidine in older adults, limiting its dose (≤600 mg/day) and duration of use (≤48 h). The objective of this study was to determine the level of meperidine use in older adults and assess the dosage and duration of meperidine with reference to these safety recommendations. A longitudinal study using administrative healthcare data was conducted to examine meperidine utilization and levels of high dose and extended duration prescribing among persons ≥65 years of age between April 1, 2001, and March 31, 2014 in Manitoba, Canada. The number of meperidine prescriptions, users, duration of treatment, defined daily doses (DDD) dispensed and number of prescribers were determined over the study period. In the Manitoba older adult population there was a marked decline in meperidine users and prescriptions from 2001 to 2014. There was an average use of 26.4 (95 % CI 24.0-28.8) DDDs of meperidine per user per year. While only 3.7 % of the prescriptions exceeded the 600 mg maximum daily dose, 96.7 % of prescriptions exceeded the recommended 2 days of therapy. For the remaining users of meperidine, the amount of meperidine used per person rose from 18.98 to 56.14 DDDs/user/year over the study period. The number of prescribers of meperidine declined throughout the study, but low DDD prescribers declined more quickly than high DDD prescribers. While meperidine use has declined, the remaining use appears to be decreasing in safety, with more meperidine prescribed per user. This seems to be driven by

  6. 75 deaths in asthmatics prescribed home nebulisers.

    Science.gov (United States)

    Sears, M R; Rea, H H; Fenwick, J; Gillies, A J; Holst, P E; O'Donnell, T V; Rothwell, R P

    1987-02-21

    The circumstances surrounding the deaths of 75 asthmatic patients who had been prescribed a domiciliary nebuliser driven by an air compressor pump for administration of high dose beta sympathomimetic drugs were investigated as part of the New Zealand national asthma mortality study. Death was judged unavoidable in 19 patients who seemed to have precipitous attacks despite apparently good long term management. Delays in seeking medical help because of overreliance on beta agonist delivered by nebuliser were evident in 12 cases and possible in a further 11, but these represented only 8% of the 271 verified deaths from asthma in New Zealanders aged under 70 during the period. Evidence for direct toxicity of high dose beta agonist was not found. Nevertheless, the absence of serum potassium and theophylline concentrations and of electrocardiographic monitoring in the period immediately preceding death precluded firm conclusions whether arrhythmias might have occurred due to these factors rather than to hypoxia alone. In most patients prescribed domiciliary nebulisers death was associated with deficiencies in long term and short term care similar to those seen in patients without nebulisers. Discretion in prescribing home nebulisers, greater use of other appropriate drugs, including adequate corticosteroids, and careful supervision and instruction of patients taking beta agonist by nebuliser should help to reduce the mortality from asthma.

  7. Assessment of dose homogeneity in conformal interstitial breast brachytherapy with special respect to ICRU recommendations

    Directory of Open Access Journals (Sweden)

    Tibor Major

    2011-09-01

    Full Text Available Purpose: To present the results of dose homogeneity analysis for breast cancer patients treated with image-basedconformal interstitial brachytherapy, and to investigate the usefulness of the ICRU recommendations. Material and methods: Treatment plans of forty-nine patients who underwent partial breast irradiation with interstitialbrachytherapy were analyzed. Quantitative parameters were used to characterize dose homogeneity. Dose nonuniformityratio (DNR, dose homogeneity index (DHI, uniformity index (UI and quality index (QI were calculated.Furthermore, parameters recommended by the ICRU 58 such as minimum target dose (MTD, mean central dose (MCD,high dose volume, low dose volume and the spread between local minimum doses were determined. Correlationsbetween the calculated homogeneity parameters and usefulness of the ICRU parameters in image-based brachytherapywere investigated. Results: Catheters with mean number of 15 (range: 6-25 were implanted in median 4 (range: 3-6 planes. The volu -me of the PTV ranged from 15.5 cm3 to 176 cm3. The mean DNR was 0.32, the DHI 0.66, the UI 1.49 and the QI 1.94. Relatedto the prescribed dose, the MTD was 69% and the MCD 135%. The mean high dose volume was 8.1 cm3 (10%, whilethe low dose volume was 63.8 cm3 (96%. The spread between minimum doses in central plane ranged from –14% to+20%. Good correlation was found between the DNR and the DHI (R2 = 0.7874, and the DNR correlated well with theUI (R2 = 0.7615 also. No correlation was found between the ICRU parameters and any other volumetric parameters. Conclusions: To characterize the dose uniformity in high-dose rate breast implants, DVH-related homogeneityparameters representing the full 3D dose distributions are mandatory to be used. In many respects the current re commendationsof the ICRU Report 58 are already outdated, and it is well-timed to set up new recommendations, whichare more feasible for image-guided conformal interstitial brachytherapy.

  8. Oral penicillin prescribing for children in the UK: a comparison with BNF for Children age-band recommendations

    Science.gov (United States)

    Saxena, Sonia; Ismael, Zareen; Murray, Macey L; Barker, Charlotte; Wong, Ian CK; Sharland, Mike; Long, Paul F

    2014-01-01

    Background The British National Formulary for Children (BNFC) recommends dosing oral penicillins according to age-bands, weight-bands, or weight-based calculations. Because of the rising prevalence of childhood obesity, age-band-based prescribing could lead to subtherapeutic dosing. Aim To investigate actual oral penicillin prescribing by GPs in the UK with reference to the current BNFC age-band recommendations. Design and setting Descriptive analysis of UK prescriptions in the 2010 IMS Disease-Analyzer database (IMS-DA). Method A detailed database analysis was undertaken of oral penicillin prescriptions for 0–18 year olds from the 2010 IMS-DA. The prescription analysis included all available data on formulation, strength (mg), prescription quantity unit, package size, prescribed quantity, and volume. Results Considering amoxicillin alone, no infants (aged penicillins for children in UK primary care, with very few children being prescribed the current national recommended doses. There is an urgent need to review dosing guidelines, in relation to the weights of children today. PMID:24686886

  9. An electronic intervention to improve safety for pain patients co-prescribed chronic opioids and benzodiazepines.

    Science.gov (United States)

    Zaman, Tauheed; Rife, Tessa L; Batki, Steven L; Pennington, David L

    2018-03-29

    Co-prescribing opioids and benzodiazepines increases overdose risk. A paucity of literature exists evaluating strategies to improve safety of co-prescribing. This study evaluated an electronic intervention to improve safety for patients co-prescribed chronic opioids for pain and benzodiazepines at 3 and 6 months. A prospective cohort study was conducted from December 2015 through May 2016 at San Francisco Veterans Affairs Health Care System. A clinical dashboard identified 145 eligible patients prescribed chronic opioids and benzodiazepines. Individualized taper and safety recommendations were communicated to prescribers via electronic medical record progress note and encrypted e-mail at baseline. Primary outcome was number of patients co-prescribed chronic opioids and benzodiazepines. Secondary outcomes included daily dose of opioids and benzodiazepines and number prescribed ≥100 mg morphine equivalent daily dose. Safety outcomes included number with opioid overdose education and naloxone distribution, annual urine drug screening, annual prescription drug monitoring program review, and signed opioid informed consent. Linear mixed models and generalized estimating equations were used to examine within-group change in outcomes between baseline and 3 and 6 months. Among the 145 patients, mean (standard deviation) age was 62 (11) years and 91.7% (133/145) were male. Number co-prescribed significantly decreased from 145/145 (100%) at baseline to 93/139 (67%) at 6-month follow-up (odds ratio [OR] = 0.53, 95% confidence interval [CI]: 0.34-0.81, P = .003). Mean opioid and benzodiazepine doses significantly decreased from 84.61 to 65.63 mg (95% CI: 8.32-27.86, P improve safety for patients co-prescribed chronic opioids for pain and benzodiazepines.

  10. Trends in metformin utilisation and dose appropriateness in Australia.

    Science.gov (United States)

    Moon, J; Kumar, S S; Graham, G G; Baysari, M T; Williams, K M; Chen, W; Viardot, A; Greenfield, J R; Day, R O

    2016-12-01

    The study aimed to (1) determine the trends in the utilisation of metformin in Australia, (2) determine the appropriateness of metformin dosing in an Australian teaching hospital and (3) gather the opinions of prescribers on the relationship between metformin dose and renal function. National prescription data between 1990 and 2012 were accessed. A retrospective audit (2008-2012) of metformin doses and patient renal function (20 % random sample of all in-patients prescribed metformin) was conducted at St Vincent's Hospital (SVH), Sydney. Prescribers of metformin were interviewed (semi-structured; consultants at SVH) or surveyed (Australian endocrinologists) to gather their understanding of metformin dosing in relation to renal function. Metformin utilisation increased fivefold nationally between 1995 and 2012. Metformin tended to be under-dosed in SVH patients with normal renal function (83.5 %) and over-dosed in patients with impaired renal function (estimated glomerular filtration rate (eGFR) metformin doses needed to be reduced in renal impairment. Most endocrinologists (61 %) were comfortable prescribing metformin down to eGFRs around 30 mL/min. The use of metformin increased greatly over the period of the study. Metformin is prescribed frequently for patients with eGFR values below the minimal level approved in the product label (60 mL/min). While prescribers expressed their understanding of the need to reduce metformin doses in patients with renal impairment, we found that metformin doses were higher than appropriate in patients with impaired renal function. Metformin may be used safely when renal function is poor provided dosage is appropriately reduced.

  11. Dose distribution over the radiation field and organs of the body during radiotherapy procedures

    International Nuclear Information System (INIS)

    Roy, S.; Begum, M.; Ambia, A.S.M.; Akhter, S.; Banu, H.

    2001-01-01

    Beam profile of the 60 Co teletherapy unit for 10 cm x 10 cm along central axis was measured to study the symmetry of the gamma beam and found that the average dose was 98.44±1.40 mGy. Output dose versus field size was also measured and values were found reasonable. Dose prescription to delivery was measured by placing TLD onto the treatment field for lung and cervix cancer patient which was found to be 39.16±2.98 Gy and 50.48±3.68 Gy respectively which are within 2 % and 0.17 % of the prescribed dose as 40.00 and 50.40 Gy respectively, reveals good agreement with the treatment planning. Six typical types of patients (both male and female) with cancers in lung, larynx, breast, cervix, oesophagus and brain treated with 60 Co teletherapy were particularly considered for dose assessment at different critical organs of interest. It was observed that the doses to the lens of eye with a maximum value of 460.35+78.87 mGy for a larynx cancer patient to a minimum value of 30.80+4.00 mGy of a cervix cancer patient. Doses to the gonad vary with a maximum value of 3810.80+389.76 mGy for a cervix cancer patient to a minimum value of 8.20+1.00 mGy for a brain cancer patient. (author)

  12. Antipsychotic treatment dosing profile in patients with schizophrenia evaluated with electronic monitoring (MEMS®).

    Science.gov (United States)

    Acosta, Francisco J; Ramallo-Fariña, Yolanda; Bosch, Esperanza; Mayans, Teresa; Rodríguez, Carlos J; Caravaca, Ana

    2013-05-01

    Although the Medication Event Monitoring System (MEMS®) device offers accurate information on treatment dosing profile, such profile has never been studied in patients with schizophrenia. Enhancing our knowledge on this issue would help in developing intervention strategies to improve adherence to antipsychotic treatment in these patients. 74 outpatients with schizophrenia were monitored with the MEMS device for a 3-month period, for evaluation of antipsychotic treatment dosing profile, possible influence of medication schedule-related variables, adherence to treatment--considering dose intake within prescribed timeframes--and possible Hawthorne's effect of using the MEMS device. Dose-omission gaps occurred in 18.7% of monitoring days, most frequently during weekends, almost significantly. Almost one-third of prescribed doses were taken out of prescribed time. Neither the prescribed number of daily doses nor the indicated time of the day for dose intake (breakfast, dinner), were associated with correct antipsychotic dosing. Excess-dose was rare in general, and more frequent out of prescribed dose timeframe. No Hawthorne's effect was found for the MEMS device. Adherence reached only 35% according to a definition that included dose intake within prescribed timeframes. Antipsychotic treatment dosing was considerably irregular among patients with schizophrenia. Strategies to reduce dose-omission gaps and increase dosing within prescribed timeframes seem to be necessary. Gaining knowledge on precise oral antipsychotic dosing profiles or the influence of schedule-related variables may be useful to design strategies towards enhancing adherence. There appears to be no Hawthorne's effect associated with the use of MEMS devices in outpatients with schizophrenia. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Psychotropic prescribing in seriously violent men with schizophrenia or personality disorder in a UK high security hospital.

    Science.gov (United States)

    Stone-Brown, Keir; Naji, Mahmood; Francioni, Alex; Myers, Kyle; Samarendra, Harsh; Mushtaq-Chaudhry, Haseeb; Heslop, Stephen; Sengupta, Samrat; Ross, Callum C; Larkin, Fintan; Das, Mrigendra

    2016-02-01

    To analyze antipsychotic prescribing patterns in a UK high security hospital (HSH) that treats seriously violent men with either schizophrenia or personality disorder and examine how different groups consented to treatment and prescribing for metabolic conditions. We hypothesized that there would be high prevalence of antipsychotic polypharmacy, and high-dose antipsychotic and clozapine prescribing. HSHs treat seriously violent, mentally disordered offenders, and the extant literature on prescribing patterns in forensic settings is sparse. Prescribing and clinical data on all 189 patients in a UK HSH were collected from the hospital's databases. Data were analyzed using SPSS. The population was split into the following groups: schizophrenia spectrum disorder (SSD-only), personality disorder (PD-only), and comorbid schizophrenia spectrum disorder and PD. The majority (93.7%) of all patients were prescribed at least one antipsychotic, and (27.5%) were on clozapine. Polypharmacy was prevalent in 22.2% and high-dose antipsychotic in 27.5%. Patients on clozapine were more likely to be prescribed antidiabetic, statins, or antihypertensive medication. Patients in the PD-only group were more likely to be deemed to have the capacity to consent to treatment and be prescribed clozapine in contrast to the SSD-only group. Rates of clozapine and high-dose antipsychotic prescribing were higher than in other psychiatric settings, while polypharmacy prescribing rates were lower. Higher clozapine prescribing rates may be a function of a treatment-resistant and aggressive population. A higher proportion of PD-only patients consented to treatment and received clozapine compared with in-house SSD-only as well as other psychiatric settings. Implications of the findings are discussed.

  14. Specialist pediatric palliative care prescribing practices: A large 5-year retrospective audit

    Directory of Open Access Journals (Sweden)

    Anuja Damani

    2016-01-01

    Full Text Available Introduction: There is a gradual increasing trend in childhood cancers in India and pediatric palliative care in India is an emerging specialty. Prescribing pain and symptom control drugs in children with cancer requires knowledge of palliative care formulary, dosing schedules, and prescription guidelines. This study is a retrospective audit of prescribing practices of a specialist palliative care service situated in a tertiary cancer center. Methods: A total of 1135 medication records of children receiving specialist pediatric palliative care services were audited for 5 years (2010-2014 to evaluate prescribing practices in children with advanced cancer. Results: A total of 51 types of drugs were prescribed with an average of 4.2 drugs per prescription. 66.9% of the prescriptions had paracetamol, and 33.9% of the prescriptions had morphine. Most common nonsteroidal anti-inflammatory drugs prescribed was ibuprofen (23.9%, and more than 50% of the prescriptions had aperients. The most commonly prescribed aperient was a combination of liquid paraffin and sodium-picosulfate. Dexamethasone was prescribed in 51.9% of patients and in most cases this was part of oral chemotherapy regimen. Generic names in prescription were used only in 33% of cases, and adverse effects of the drugs were documented in only 9% of cases. In 25% of cases, noncompliance to the WHO prescription guidelines was seen, and patient compliance to prescription was seen in 40% of cases. Conclusions: Audit of the prescribing practices in specialist pediatric palliative care service shows that knowledge of pediatric palliative care formulary, rational drug use, dosing, and prescribing guidelines is essential for symptom control in children with advanced life-limiting illness. Noncompliance to WHO prescribing guidelines in one fourth of cases and using nongeneric names in two-thirds of prescription indicates poor prescribing practices and warrants prescriber education. Prescription

  15. The Effect of Dose-Volume Parameters and Interfraction Interval on Cosmetic Outcome and Toxicity After 3-Dimensional Conformal Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Leonard, Kara Lynne; Hepel, Jaroslaw T.; Hiatt, Jessica R.; Dipetrillo, Thomas A.; Price, Lori Lyn; Wazer, David E.

    2013-01-01

    Purpose: To evaluate dose-volume parameters and the interfraction interval (IFI) as they relate to cosmetic outcome and normal tissue effects of 3-dimensional conformal radiation therapy (3D-CRT) for accelerated partial breast irradiation (APBI). Methods and Materials: Eighty patients were treated by the use of 3D-CRT to deliver APBI at our institutions from 2003-2010 in strict accordance with the specified dose-volume constraints outlined in the National Surgical Adjuvant Breast and Bowel Project B39/Radiation Therapy Oncology Group 0413 (NSABP-B39/RTOG 0413) protocol. The prescribed dose was 38.5 Gy in 10 fractions delivered twice daily. Patients underwent follow-up with assessment for recurrence, late toxicity, and overall cosmetic outcome. Tests for association between toxicity endpoints and dosimetric parameters were performed with the chi-square test. Univariate logistic regression was used to evaluate the association of interfraction interval (IFI) with these outcomes. Results: At a median follow-up time of 32 months, grade 2-4 and grade 3-4 subcutaneous fibrosis occurred in 31% and 7.5% of patients, respectively. Subcutaneous fibrosis improved in 5 patients (6%) with extended follow-up. Fat necrosis developed in 11% of women, and cosmetic outcome was fair/poor in 19%. The relative volume of breast tissue receiving 5%, 20%, 50%, 80%, and 100% (V5-V100) of the prescribed dose was associated with risk of subcutaneous fibrosis, and the volume receiving 50%, 80%, and 100% (V50-V100) was associated with fair/poor cosmesis. The mean IFI was 6.9 hours, and the minimum IFI was 6.2 hours. The mean and minimum IFI values were not significantly associated with late toxicity. Conclusions: The incidence of moderate to severe late toxicity, particularly subcutaneous fibrosis and fat necrosis and resulting fair/poor cosmesis, remains high with continued follow-up. These toxicity endpoints are associated with several dose-volume parameters. Minimum and mean IFI values were

  16. Evaluation of prescriber responses to pharmacogenomics clinical decision support for thiopurine S-methyltransferase testing.

    Science.gov (United States)

    Ubanyionwu, Samuel; Formea, Christine M; Anderson, Benjamin; Wix, Kelly; Dierkhising, Ross; Caraballo, Pedro J

    2018-02-15

    Results of a study of prescribers' responses to a pharmacogenomics-based clinical decision support (CDS) alert designed to prompt thiopurine S -methyltransferase (TPMT) status testing are reported. A single-center, retrospective, chart review-based study was conducted to evaluate prescriber compliance with a pretest CDS alert that warned of potential thiopurine drug toxicity resulting from deficient TPMT activity due to TPMT gene polymorphism. The CDS alert was triggered when prescribers ordered thiopurine drugs for patients whose records did not indicate TPMT status or when historical thiopurine use was documented in the electronic health record. The alert pop-up also provided a link to online educational resources to guide thiopurine dosing calculations. During the 9-month study period, 500 CDS alerts were generated: in 101 cases (20%), TPMT phenotyping or TPMT genotyping was ordered; in 399 cases (80%), testing was not ordered. Multivariable regression analysis indicated that documentation of historical thiopurine use was the only independent predictor of test ordering. Among the 99 patients tested subsequent to CDS alerts, 70 (71%) had normal TPMT activity, 29 (29%) had intermediate activity, and none had deficient activity. The online resources provided thiopurine dosing recommendations applicable to 24 patients, but only 3 were prescribed guideline-supported doses after CDS alerts. The pretest CDS rule resulted in a large proportion of neglected alerts due to poor alerting accuracy and consequent alert fatigue. Prescriber usage of online thiopurine dosing resources was low. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  17. Assessing pediatrics residents' mathematical skills for prescribing medication: a need for improved training.

    Science.gov (United States)

    Glover, Mark L; Sussmane, Jeffrey B

    2002-10-01

    To evaluate residents' skills in performing basic mathematical calculations used for prescribing medications to pediatric patients. In 2001, a test of ten questions on basic calculations was given to first-, second-, and third-year residents at Miami Children's Hospital in Florida. Four additional questions were included to obtain the residents' levels of training, specific pediatrics intensive care unit (PICU) experience, and whether or not they routinely double-checked doses and adjusted them for each patient's weight. The test was anonymous and calculators were permitted. The overall score and the score for each resident class were calculated. Twenty-one residents participated. The overall average test score and the mean test score of each resident class was less than 70%. Second-year residents had the highest mean test scores, although there was no significant difference between the classes of residents (p =.745) or relationship between the residents' PICU experiences and their exam scores (p =.766). There was no significant difference between residents' levels of training and whether they double-checked their calculations (p =.633) or considered each patient's weight relative to the dose prescribed (p =.869). Seven residents committed tenfold dosing errors, and one resident committed a 1,000-fold dosing error. Pediatrics residents need to receive additional education in performing the calculations needed to prescribe medications. In addition, residents should be required to demonstrate these necessary mathematical skills before they are allowed to prescribe medications.

  18. Does fire severity influence shrub resprouting after spring prescribed burning?

    Science.gov (United States)

    Fernández, Cristina; Vega, José A.; Fonturbel, Teresa

    2013-04-01

    Prescribed burning is commonly used to reduce the risk of severe wildfire. However, further information about the associated environmental effects is required to help forest managers select the most appropriate treatment. To address this question, we evaluated if fire severity during spring prescribed burning significantly affects the resprouting ability of two common shrub species in shrubland under a Mediterranean climate in NW Spain. Fire behaviour and temperatures were recorded in tagged individuals of Erica australis and Pterospartum tridentatum during prescribed burning. The number and length of resprouted shoots were measured three times (6, 12 and 18 months) after the prescribed burning. The influence of a series of fire severity indicators on some plant resprouting vigour parameters was tested by canonical correlation analysis. Six months and one year after prescribed burning, soil burn severity (measured by the absolute reduction in depth of the organic soil layer, maximum temperatures in the organic soil layer and the mineral soil surface during burning and the post-fire depth of the organic soil layer) reduced the resprouting vigour of E. australis and P. tridentatum. In contrast, direct measurements of fire effects on plants (minimum branch diameter, duration of temperatures above 300 °C in the shrub crown and fireline intensity) did not affect the post-fire plant vigour. Soil burn severity during spring prescribed burning significantly affected the short-term resprouting vigour in a mixed heathland in Galicia. The lack of effects eighteen months after prescribed burning indicates the high resilience of these species and illustrates the need to conciliate fire prevention and conservation goals.

  19. Improving the prescribing of antibiotics for urinary tract infection.

    Science.gov (United States)

    Peterson, G M; Stanton, L A; Bergin, J K; Chapman, G A

    1997-04-01

    In recent years there have been changes in the recommended antibiotic treatment for urinary tract infections (UTIs). In particular, the use of amoxycillin or co-trimoxazole is now discouraged, with amoxycillin-potassium clavulanate, cephalexin and trimethoprim becoming first-line agents for uncomplicated lower UTIs. To examine whether academic detailing, performed by a pharmacist, could modify prescribing practices for antibiotics used in the treatment of UTI in the community setting. The intervention was conducted in Southern Tasmania, using the remainder of the State as a control area. The target group of general practitioners was sent educational material designed to assist in the appropriate prescribing of antibiotics in the treatment of UTI. A pharmacist then visited each general practitioner and discussed the rational use of antibiotics for UTIs directly with him/her. Outcomes were measured using evaluation feedback from the general practitioners and pharmacoepidemiological data, which were not linked to diagnosis. The key variable examined was the total defined daily doses (DDDs) dispensed for the recommended first-line agents (amoxycillin-potassium clavulanate, cephalexin and trimethoprim) compared with amoxycillin (3 g single-dose form) and co-trimoxazole. The educational programme was very well received by the general practitioners. Changes in the prescribing of antibiotics commonly used for UTIs were evident in both study regions over the course of the study, but the improvements were significantly greater in the intervention area. Educational programmes utilizing academic detailing by pharmacists can modify prescribing practices within the community setting.

  20. Nurse prescribing in dermatology: doctors' and non-prescribing nurses' views.

    Science.gov (United States)

    Stenner, Karen; Carey, Nicola; Courtenay, Molly

    2009-04-01

    This paper is a report of a study conducted to explore doctor and non-prescribing nurse views about nurse prescribing in the light of their experience in dermatology. The cooperation of healthcare professionals and peers is of key importance in enabling and supporting nurse prescribing. Lack of understanding of and opposition to nurse prescribing are known barriers to its implementation. Given the important role they play, it is necessary to consider how the recent expansion of nurse prescribing rights in England impacts on the views of healthcare professionals. Interviews with 12 doctors and six non-prescribing nurses were conducted in 10 case study sites across England between 2006 and 2007. Participants all worked with nurses who prescribed for patients with dermatological conditions in secondary or primary care. Thematic analysis was conducted on the interview data. Participants were positive about their experiences of nurse prescribing having witnessed benefits from it, but had reservations about nurse prescribing in general. Acceptance was conditional upon the nurses' level of experience, awareness of their own limitations and the context in which they prescribed. Fears that nurses would prescribe beyond their level of competence were expected to reduce as understanding and experience of nurse prescribing increased. Indications are that nurse prescribing can be acceptable to doctors and nurses so long as it operates within recommended parameters. Greater promotion and assessment of standards and criteria are recommended to improve understanding and acceptance of nurse prescribing.

  1. The impact of a closed-loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before-and-after study.

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-08-01

    To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; chi(2) test). A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.

  2. Dose Escalated Liver Stereotactic Body Radiation Therapy at the Mean Respiratory Position

    International Nuclear Information System (INIS)

    Velec, Michael; Moseley, Joanne L.; Dawson, Laura A.; Brock, Kristy K.

    2014-01-01

    Purpose: The dosimetric impact of dose probability based planning target volume (PTV) margins for liver cancer patients receiving stereotactic body radiation therapy (SBRT) was compared with standard PTV based on the internal target volume (ITV). Plan robustness was evaluated by accumulating the treatment dose to ensure delivery of the intended plan. Methods and Materials: Twenty patients planned on exhale CT for 27 to 50 Gy in 6 fractions using an ITV-based PTV and treated free-breathing were retrospectively evaluated. Isotoxic, dose escalated plans were created on midposition computed tomography (CT), representing the mean breathing position, using a dose probability PTV. The delivered doses were accumulated using biomechanical deformable registration of the daily cone beam CT based on liver targeting at the exhale or mean breathing position, for the exhale and midposition CT plans, respectively. Results: The dose probability PTVs were on average 38% smaller than the ITV-based PTV, enabling an average ± standard deviation increase in the planned dose to 95% of the PTV of 4.0 ± 2.8 Gy (9 ± 5%) on the midposition CT (P<.01). For both plans, the delivered minimum gross tumor volume (GTV) doses were greater than the planned nominal prescribed dose in all 20 patients and greater than the planned dose to 95% of the PTV in 18 (90%) patients. Nine patients (45%) had 1 or more GTVs with a delivered minimum dose more than 5 Gy higher with the midposition CT plan using dose probability PTV, compared with the delivered dose with the exhale CT plan using ITV-based PTV. Conclusions: For isotoxic liver SBRT planned and delivered at the mean respiratory, reduced dose probability PTV enables a mean escalation of 4 Gy (9%) in 6 fractions over ITV-based PTV. This may potentially improve local control without increasing the risk of tumor underdosing

  3. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    International Nuclear Information System (INIS)

    Zhou, Yifang; Scott, Alexander II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-01-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R 2   >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented. (paper)

  4. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    Science.gov (United States)

    Zhou, Yifang; Scott, Alexander, II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-10-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R^2  >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented.

  5. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    Science.gov (United States)

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  6. Design objectives with non-zero prescribed support displacements

    DEFF Research Database (Denmark)

    Pedersen, Pauli; Pedersen, Niels Leergaard

    2011-01-01

    When non-zero prescribed support displacements are involved in addition to design independent loads for a continuum/structure, then the objectives of minimum compliance (total elastic energy) and of maximum strength lead to different designs. This is verified by the presented sensitivities. Designs...... minimization as well as that of direct strength maximization; we choose the objective of obtaining uniform energy density and show by examples that the obtained solutions are close to fulfilling also strength maximization, with the price of increased compliance. Optimal design examples are presented...

  7. Social determinants of prescribed and non-prescribed medicine use

    Directory of Open Access Journals (Sweden)

    García-Altés Anna

    2010-05-01

    Full Text Available Abstract Background The aim of the present study was to describe the use of prescribed and non prescribed medicines in a non-institutionalised population older than 15 years of an urban area during the year 2000, in terms of age and gender, social class, employment status and type of Primary Health Care. Methods Cross-sectional study. Information came from the 2000 Barcelona Health Interview Survey. The indicators used were the prevalence of use of prescribed and non-prescribed medicines in the two weeks prior to the interview. Descriptive analyses, bivariate and multivariate logistic regression analyses were carried out. Results More women than men took medicines (75.8% vs. 60% respectively. The prevalence of use of prescribed medicines increased with age while the prevalence of non-prescribed use decreased. These age differences are smaller among those with poor perceived health. In terms of social class, a higher percentage of men with good health in the more advantaged classes took non-prescribed medicines compared with disadvantaged classes (38.7% vs 31.8%. In contrast, among the group with poor health, more people from the more advantaged classes took prescribed medicines, compared with disadvantaged classes (51.4% vs 33.3%. A higher proportion of people who were either retired, unemployed or students, with good health, used prescribed medicines. Conclusion This study shows that beside health needs, there are social determinants affecting medicine consumption in the city of Barcelona.

  8. Identifying fallacious arguments in a qualitative study of antipsychotic prescribing in dementia.

    Science.gov (United States)

    Donyai, Parastou

    2017-10-01

    Dementia can result in cognitive, noncognitive and behavioural symptoms which are difficult to manage. Formal guidelines for the care and management of dementia in the UK state that antipsychotics should only be prescribed where fully justified. This is because inappropriate use, particularly problematic in care-home settings, can produce severe side effects including death. The aim of this study was to explore the use of fallacious arguments in professionals' deliberations about antipsychotic prescribing in dementia in care-home settings. Fallacious arguments have the potential to become unremarkable discourses that construct and validate practices which are counter to guidelines. This qualitative study involved interviews with 28 care-home managers and health professionals involved in caring for patients with dementia. Potentially fallacious arguments were identified using qualitative content analysis and a coding framework constructed from existing explanatory models of fallacious reasoning. Fallacious arguments were identified in a range of explanations and reasons that participants gave for in answer to questions about initiating, reducing doses of and stopping antipsychotics in dementia. The dominant fallacy was false dichotomy. Appeal to popularity, tradition, consequence, emotion, or fear, and the slippery slope argument was also identified. Fallacious arguments were often formulated to present convincing cases whereby prescribing antipsychotics or maintaining existing doses (versus not starting medication or reducing the dose, for example) appeared as the only acceptable decision but this is not always the case. The findings could help health professionals to recognise and mitigate the effect of logic-based errors in decisions about the prescribing of antipsychotics in dementia. © 2016 Royal Pharmaceutical Society.

  9. The Pattern of Antibiotic Prescribing by Dental Practitioners in Zagreb, Croatia.

    Science.gov (United States)

    Perić, Marina; Perković, Ivana; Romić, Martina; Simeon, Paris; Matijević, Jurica; Mehičić, Goranka Prpić; Krmek, Silvana Jukić

    2015-06-01

    Bacterial resistance is considered a consequence of misuse or overuse of antibiotics. Dentistry significantly contributes to this increasing public health problem. The aim of this cross-sectional study was to examine the pattern of antibiotics prescribed by Croatian dentists in Zagreb area. Out of 220 Doctors of Dental Medicine (DMDs) from Zagreb 110 responded to survey. Prior to the research an ethical approval was obtained. Participants were directly contacted. The questionnaire consisted of two parts: general data on DMDs and the part concerning indications, duration, type and dosage of antibiotic therapy. Data were processed using MS Excel and SPSS for Windows, Version 17.0. Statistical significance was tested by Fisher's exact test, chi-square test, Mann-Whitney U test and Spearman's rank correlation at the level of statistical significance p<0.05. During the period of two months, the doctors prescribed antibiotics to 1,500 patients, 690 (46%) were men and 810 (54%) women. The most often prescribed antibiotics were penicillin (72.5% of patients), represented mostly by amoxicillin in combination with clavulanic acid (57.6%). The most common indication for the prescribed antibiotics was periapical or periodontal abscess (44%). Definite clinical indication (71.2%) was stated as the most common reason for antibiotic prescription. Antibiotic therapy usually lasted 7 days (62.9%). The doctors prescribed daily doses of antibiotics according to the instructions for the use of specific drugs. The examined subjects prescribe antibiotics according to the curriculum taught at the School of Dental Medicine for majority of types, doses and duration of the treatments, although antibiotics over-prescription in cases without medical indication was observed. The national guidelines on antibiotic regimens are required in order to reduce unnecessary antibiotic use. Copyright© by the National Institute of Public Health, Prague 2015.

  10. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  11. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  12. The impact of a closed‐loop electronic prescribing and administration system on prescribing errors, administration errors and staff time: a before‐and‐after study

    Science.gov (United States)

    Franklin, Bryony Dean; O'Grady, Kara; Donyai, Parastou; Jacklin, Ann; Barber, Nick

    2007-01-01

    Objectives To assess the impact of a closed‐loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants Before‐and‐after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention Closed‐loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results Prescribing errors were identified in 3.8% of 2450 medication orders pre‐intervention and 2.0% of 2353 orders afterwards (pMedical staff required 15 s to prescribe a regular inpatient drug pre‐intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre‐intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions A closed‐loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication‐related tasks increased. PMID:17693676

  13. E-Prescribing Errors in Community Pharmacies: Exploring Consequences and Contributing Factors

    Science.gov (United States)

    Stone, Jamie A.; Chui, Michelle A.

    2014-01-01

    Objective To explore types of e-prescribing errors in community pharmacies and their potential consequences, as well as the factors that contribute to e-prescribing errors. Methods Data collection involved performing 45 total hours of direct observations in five pharmacies. Follow-up interviews were conducted with 20 study participants. Transcripts from observations and interviews were subjected to content analysis using NVivo 10. Results Pharmacy staff detected 75 e-prescription errors during the 45 hour observation in pharmacies. The most common e-prescribing errors were wrong drug quantity, wrong dosing directions, wrong duration of therapy, and wrong dosage formulation. Participants estimated that 5 in 100 e-prescriptions have errors. Drug classes that were implicated in e-prescribing errors were antiinfectives, inhalers, ophthalmic, and topical agents. The potential consequences of e-prescribing errors included increased likelihood of the patient receiving incorrect drug therapy, poor disease management for patients, additional work for pharmacy personnel, increased cost for pharmacies and patients, and frustrations for patients and pharmacy staff. Factors that contribute to errors included: technology incompatibility between pharmacy and clinic systems, technology design issues such as use of auto-populate features and dropdown menus, and inadvertently entering incorrect information. Conclusion Study findings suggest that a wide range of e-prescribing errors are encountered in community pharmacies. Pharmacists and technicians perceive that causes of e-prescribing errors are multidisciplinary and multifactorial, that is to say e-prescribing errors can originate from technology used in prescriber offices and pharmacies. PMID:24657055

  14. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes.

    Science.gov (United States)

    Norman, Jessica L; Fixen, Danielle R; Saseen, Joseph J; Saba, Laura M; Linnebur, Sunny A

    2017-01-01

    Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release) or 6.25 mg (controlled release) per night in women. The primary objective of this study was to compare prescribing practices before and after the 2013 zolpidem labeling change. A secondary objective was to evaluate serious adverse events potentially related to zolpidem. Electronic medical records of adults receiving care through the University of Colorado Health system were accessed for study inclusion if patients were provided a first-time prescription for zolpidem either prior to or after the Food and Drug Administration labeling change. Patients were randomly chosen from eight strata based on age, gender, and date of zolpidem initiation (before/after the labeling change). Demographic and zolpidem prescribing data were collected. Low-dose zolpidem was considered 5 mg (immediate release) or 6.25 mg (controlled release) daily or less. Documentation of potentially related serious adverse events within the patients' records was also evaluated. A total of 400 patients were included in the study. The overall percentage of patients prescribed low-dose zolpidem increased from 44% to 58% after the labeling change (p = 0.0020). In a pre-specified subgroup analysis, the percentage of patients prescribed low-dose zolpidem increased in all groups, including young men (38%-50%, p = 0.23), elderly men (34%-40%, p = 0.53), and elderly women (60%-74%, p = 0.14), but the change was only significant in young women (42%-70%, p = 0.0045). After Food and Drug Administration-mandated labeling changes for zolpidem in 2013, the percentage of overall patients in our health system, and specifically young women, with initial prescriptions for low-dose

  15. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes

    Directory of Open Access Journals (Sweden)

    Jessica L Norman

    2017-05-01

    Full Text Available Background: Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release or 6.25 mg (controlled release per night in women. Objectives: The primary objective of this study was to compare prescribing practices before and after the 2013 zolpidem labeling change. A secondary objective was to evaluate serious adverse events potentially related to zolpidem. Methods: Electronic medical records of adults receiving care through the University of Colorado Health system were accessed for study inclusion if patients were provided a first-time prescription for zolpidem either prior to or after the Food and Drug Administration labeling change. Patients were randomly chosen from eight strata based on age, gender, and date of zolpidem initiation (before/after the labeling change. Demographic and zolpidem prescribing data were collected. Low-dose zolpidem was considered 5 mg (immediate release or 6.25 mg (controlled release daily or less. Documentation of potentially related serious adverse events within the patients’ records was also evaluated. Results: A total of 400 patients were included in the study. The overall percentage of patients prescribed low-dose zolpidem increased from 44% to 58% after the labeling change (p = 0.0020. In a pre-specified subgroup analysis, the percentage of patients prescribed low-dose zolpidem increased in all groups, including young men (38%–50%, p = 0.23, elderly men (34%–40%, p = 0.53, and elderly women (60%–74%, p = 0.14, but the change was only significant in young women (42%–70%, p = 0.0045. Conclusion: After Food and Drug Administration–mandated labeling changes for zolpidem in 2013, the percentage of overall patients in our health

  16. Use of a concise prescription for specifying absolute dose distribution in external beam radiation therapy

    International Nuclear Information System (INIS)

    Viggers, D.A.; Shalev, S.

    1989-01-01

    Radiation therapy dose distributions are usually calculated relative to some normalization point to which a prescribed dose in grays is to be delivered. Often the radiation therapist requests that the prescribed dose be delivered to some other point(s), such as the 90% isodose. Therefore the prescribed dose is not well defined. Furthermore, this procedure leaves the shape of the dose distribution unspecified. The authors have used a dose prescription specifying the volumes of target and nontarget tissue that must lie within dose limits stated in grays. These dose-volume limits determine the magnitude and shape of the dose distribution. The prescription is well defined while allowing the absolute dose at a chosen point to be adjusted so that the dose distribution satisfies the prescription

  17. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  18. Drug Use Evaluation of Three Widely Prescribed Antibiotics in a

    Directory of Open Access Journals (Sweden)

    Mehdi Mohammadi

    2015-10-01

    Full Text Available Background: Drug utilization studies are helpful in understanding the current practice. We have conducted a retrospective study to evaluate the relevant use of a group of most commonly prescribed antibiotics in a teaching hospital in Iran.  The results of this study may be of help for clinicians to improve the patient care.Methods: Patients who received parenteral ceftazidim, vancomycin and amikacin from December2010 to May 2011 were enrolled in this study. Patient’s data including demographic, length of Hospital stay, drug allergy, first and final diagnosis were recorded in a predesigned data collection form. American Hospital Formulary Services (AHFS book were used as a reference for evaluation of study drug indication and dosing according to diagnosis and microbiological culture. Defined Daily Dose (DDD of each drug extracted from Anatomic and Therapeutic Chemical classification system (ATC/DDD and drug usage data evaluated by calculating the ratio of prescribed drug to its DDD.Results: The ratio of prescribed daily dose to DDD was 0.78, 0.95 and 0.86 for amikacin, ceftazidime and vancomycin respectively. Between amikacin group, 43 patients (86% received drug empirically, the number of empiric treatments for ceftazidim and vancomycin were 45(90% and 44 patients (88%. The renal function tests (Blood Urea Nitrogen, Serum Creatinin were evaluated in 56% of amikacin group, 64% in ceftazidime group and 78% in vancomycin group.Conclusion: The results of this study indicate the need to establish continuing medical education (CME courses for physicians to familiarize them with standards required to use and monitor these agents.

  19. Contact between doctors and the pharmaceutical industry, their perceptions, and the effects on prescribing habits.

    Directory of Open Access Journals (Sweden)

    Klaus Lieb

    Full Text Available BACKGROUND: The prescribing behaviour of doctors is influenced by the pharmaceutical industry. This study investigated the extent to which contacts with pharmaceutical sales representatives (PSR and the perception of these contacts influence prescribing habits. METHOD: An online questionnaire regarding contact with PSRs and perceptions of this contact was sent to 1,388 doctors, 11.5% (n = 160 of whom completed the survey. Individual prescribing data over a year (number of prescriptions, expenditure, and daily doses for all on-patent branded, off-patent branded, and generic drugs were obtained from the Bavarian Association of Statutory Health Insurance Physicians. RESULTS: 84% of the doctors saw PSR at least once a week, and 14% daily. 69% accepted drug samples, 39% accepted stationery and 37% took part in sponsored continuing medical education (CME frequently. 5 physicians (3% accepted no benefits at all. 43% of doctors believed that they received adequate and accurate information from PSRs frequently or always and 42% believed that their prescribing habits were influenced by PSR visits occasionally or frequently. Practices that saw PSRs frequently had significantly higher total prescriptions and total daily doses (but not expenditure than practices that were less frequently visited. Doctors who believed that they received accurate information from PSRs showed higher expenditures on off-patent branded drugs (thus available as generics and a lower proportion of generics. The eschewal of sponsored CME was associated with a lower proportion of on patent-branded drug prescriptions, lower expenditure on off-patent branded drug prescriptions and a higher proportion of generics. Acceptance of office stationery was associated with higher daily doses. CONCLUSIONS: Avoidance of industry-sponsored CME is associated with more rational prescribing habits. Furthermore, gift acceptance and the belief that one is receiving adequate information from a PSR are

  20. Retrospective Cohort Study of Bronchial Doses and Radiation-Induced Atelectasis After Stereotactic Body Radiation Therapy of Lung Tumors Located Close to the Bronchial Tree

    International Nuclear Information System (INIS)

    Karlsson, Kristin; Nyman, Jan; Baumann, Pia; Wersäll, Peter; Drugge, Ninni; Gagliardi, Giovanna; Johansson, Karl-Axel; Persson, Jan-Olov; Rutkowska, Eva; Tullgren, Owe; Lax, Ingmar

    2013-01-01

    Purpose: To evaluate the dose–response relationship between radiation-induced atelectasis after stereotactic body radiation therapy (SBRT) and bronchial dose. Methods and Materials: Seventy-four patients treated with SBRT for tumors close to main, lobar, or segmental bronchi were selected. The association between incidence of atelectasis and bronchial dose parameters (maximum point-dose and minimum dose to the high-dose bronchial volume [ranging from 0.1 cm 3 up to 2.0 cm 3 ]) was statistically evaluated with survival analysis models. Results: Prescribed doses varied between 4 and 20 Gy per fraction in 2-5 fractions. Eighteen patients (24.3%) developed atelectasis considered to be radiation-induced. Statistical analysis showed a significant correlation between the incidence of radiation-induced atelectasis and minimum dose to the high-dose bronchial volumes, of which 0.1 cm 3 (D 0.1cm3 ) was used for further analysis. The median value of D 0.1cm3 (α/β = 3 Gy) was EQD 2,LQ = 147 Gy 3 (range, 20-293 Gy 3 ). For patients who developed atelectasis the median value was EQD 2,LQ = 210 Gy 3 , and for patients who did not develop atelectasis, EQD 2,LQ = 105 Gy 3 . Median time from treatment to development of atelectasis was 8.0 months (range, 1.1-30.1 months). Conclusion: In this retrospective study a significant dose–response relationship between the incidence of atelectasis and the dose to the high-dose volume of the bronchi is shown

  1. Topical antibiotic monotherapy prescribing practices in acne vulgaris.

    Science.gov (United States)

    Hoover, William D; Davis, Scott A; Fleischer, Alan B; Feldman, Steven R

    2014-04-01

    The aim of this study is to evaluate the frequency of dosing topical antibiotics as monotherapy in the treatment of acne vulgaris, and physician specialty prescribing these medications. This study is a retrospective review of all visits with a sole diagnosis of acne vulgaris (ICD-9-CM code 706.1) found on the National Ambulatory Medical Care Survey (NAMCS) in 1993-2010. We recorded the number of visits surveyed where acne vulgaris was the sole diagnosis, number of visits where topical antibiotics were the only treatment prescribed, and the specialty of physician in each encounter. Topical erythromycin or clindamycin were the sole medication prescribed in 0.81% of the visits recorded, with 60% of these prescriptions arising from dermatologists and 40% from non-dermatologists. The trend of prescribing topical antibiotic monotherapy is declining (p acnes to topical antibiotic regimens has led to the need to re-evaluate the use of topical antibiotics in the treatment of acne vulgaris. While the rate of topical antibiotic monotherapy is declining, their use should be reserved for situations where the direct need for antibiotics arises. If a clinician feels that antibiotics are a necessary component to acne therapy, they should be used as part of a combination regimen.

  2. Prevalence and Correlates of “High Dose” Antipsychotic Prescribing ...

    African Journals Online (AJOL)

    of 1000 mg/day is considered as high dose prescribing. Furthermore ... genetic variations.[16] ... Annals of Medical and Health Sciences Research | Jan-Mar 2013 | Vol 3 | Issue 1 |. 63 ... the unreliability of the CPZeq criteria in the view of an increasing use of ... We obtained ethical clearance from the Ethics and Research.

  3. Influence of Residual Tumor Volume and Radiation Dose Coverage in Outcomes for Clival Chordoma

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Mark W., E-mail: markmcdonaldmd@gmail.com [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana (United States); Indiana University Health Proton Therapy Center, Bloomington, Indiana (United States); Linton, Okechukwu R. [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, Indiana (United States); Moore, Michael G.; Ting, Jonathan Y. [Department of Otolaryngology, Head and Neck Surgery, Indiana University School of Medicine, Indianapolis, Indiana (United States); Cohen-Gadol, Aaron A.; Shah, Mitesh V. [Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, Indiana (United States); Goodman Campbell Brain and Spine, Indianapolis, Indiana (United States)

    2016-05-01

    Purpose: The purpose of this study was to evaluate factors associated with tumor control in clival chordomas. Methods and Materials: A retrospective review of 39 patients treated with surgery and proton therapy for clival chordomas between 2004 and 2014 was performed. The median prescribed dose was 77.4 Gy (relative biological effectiveness [RBE]); range was 70.2-79.2 Gy (RBE). Minimum and median doses to gross tumor volume (GTV), radiation dose received by 1 cm{sup 3} of GTV (D1cm{sup 3}), and the equivalent uniform dose were calculated. Receiver operating characteristics curves evaluated the predictive sensitivity and specificity for local failure of potential cutpoint values for GTV and D1cm{sup 3}. Results: After a median follow-up of 51 months, the 5-year estimate of local control (LC) was 69.6% (95% confidence interval [CI] 50.0%-89.2%), and overall survival (OS) was 81.4% (95% CI: 65.3%-97.5%). Tumor histology, GTV at the time of radiation, and prescribed radiation dose were significantly associated with local control on multivariate analysis, whereas D1cm{sup 3} was associated with overall survival. Compared to those patients whose conditions remained controlled, patients experiencing tumor failure had statistically significant larger GTVs and lower D1cm{sup 3}, and prescribed and median doses to GTV. A subset of 21 patients with GTV of ≤20 cm{sup 3} and D1cm{sup 3} of >67 Gy (RBE) had a median follow-up of 47 months. The 5-year estimate of local control in this subset was 81.1% (95% CI: 61.7%-100%; P=.004, overall comparison by GTV ≤20 cm{sup 3} stratified by D1cm{sup 3}). A D1cm{sup 3} of 74.5 Gy (RBE) had 80% sensitivity for local control and 60% specificity, whereas a GTV of 9.3 cm{sup 3} had 80% sensitivity for local control and 66.7% specificity. Conclusions: Local control of clival chordomas was associated with both smaller size of residual tumor and more complete high-dose coverage of residual tumor. Multidisciplinary care should seek

  4. Radiosurgery for brain metastases: relationship of dose and pattern of enhancement to local control

    International Nuclear Information System (INIS)

    Shiau, C.-Y.; Sneed, Penny K.; Shu, H.-K.G.; Lamborn, Kathleen R.; McDermott, Michael W.; Chang, Susan; Nowak, Peter; Petti, Paula L.; Smith, Vernon; Verhey, Lynn J.; Ho, Maria; Park, Elaine; Wara, William M.; Gutin, Philip H.; Larson, David A.

    1997-01-01

    Purpose: This study aimed to analyze dose, initial pattern of enhancement, and other factors associated with freedom from progression (FFP) of brain metastases after radiosurgery (RS). Methods and Materials: All brain metastases treated with gamma-knife RS at the University of California, San Francisco, from 1991 to 1994 were reviewed. Evaluable lesions were those with follow-up magnetic resonance or computed tomographic imaging. Actuarial FFP was calculated using the Kaplan-Meier method, measuring FFP from the date of RS to the first imaging study showing tumor progression. Controlled lesions were censored at the time of the last imaging study. Multivariate analyses were performed using a stepwise Cox proportional hazards model. Results: Of 261 lesions treated in 119 patients, 219 lesions in 100 patients were evaluable. Major histologies included adenocarcinoma (86 lesions), melanoma (77), renal cell carcinoma (21), and carcinoma not otherwise specified (17). The median prescribed RS dose was 18.5 Gy (range, 10-22) and the median tumor volume was 1.3 ml (range, 0.02-30.9). The initial pattern of contrast enhancement was homogeneous in 68% of lesions, heterogeneous in 12%, and ring-enhancing in 19%. The actuarial FFP was 82% at 6 months and 77% at 1 year for all lesions, and 93 and 90%, respectively, for 145 lesions receiving ≥ 18 Gy. Multivariate analysis showed that longer FFP was significantly associated with higher prescribed RS dose, a homogeneous pattern of contrast enhancement, and a longer interval between primary diagnosis and RS. Adjusted for these factors, adenocarcinomas had longer FFP than melanomas. No significant differences in FFP were noted among lesions undergoing RS for recurrence after prior radiotherapy (119 lesions), RS alone as initial treatment (45), or RS boost (55). Conclusion: A minimum prescribed radiosurgical dose ≥ 18 Gy yields excellent local control of brain metastases. The influence of pattern of enhancement on local control, a

  5. GTV-based prescription in SBRT for lung lesions using advanced dose calculation algorithms

    International Nuclear Information System (INIS)

    Lacornerie, Thomas; Lisbona, Albert; Mirabel, Xavier; Lartigau, Eric; Reynaert, Nick

    2014-01-01

    The aim of current study was to investigate the way dose is prescribed to lung lesions during SBRT using advanced dose calculation algorithms that take into account electron transport (type B algorithms). As type A algorithms do not take into account secondary electron transport, they overestimate the dose to lung lesions. Type B algorithms are more accurate but still no consensus is reached regarding dose prescription. The positive clinical results obtained using type A algorithms should be used as a starting point. In current work a dose-calculation experiment is performed, presenting different prescription methods. Three cases with three different sizes of peripheral lung lesions were planned using three different treatment platforms. For each individual case 60 Gy to the PTV was prescribed using a type A algorithm and the dose distribution was recalculated using a type B algorithm in order to evaluate the impact of the secondary electron transport. Secondly, for each case a type B algorithm was used to prescribe 48 Gy to the PTV, and the resulting doses to the GTV were analyzed. Finally, prescriptions based on specific GTV dose volumes were evaluated. When using a type A algorithm to prescribe the same dose to the PTV, the differences regarding median GTV doses among platforms and cases were always less than 10% of the prescription dose. The prescription to the PTV based on type B algorithms, leads to a more important variability of the median GTV dose among cases and among platforms, (respectively 24%, and 28%). However, when 54 Gy was prescribed as median GTV dose, using a type B algorithm, the variability observed was minimal. Normalizing the prescription dose to the median GTV dose for lung lesions avoids variability among different cases and treatment platforms of SBRT when type B algorithms are used to calculate the dose. The combination of using a type A algorithm to optimize a homogeneous dose in the PTV and using a type B algorithm to prescribe the

  6. Optimisation of antimicrobial dosing based on pharmacokinetic and pharmacodynamic principles

    Directory of Open Access Journals (Sweden)

    Grace Si Ru Hoo

    2017-01-01

    Full Text Available While suboptimal dosing of antimicrobials has been attributed to poorer clinical outcomes, clinical cure and mortality advantages have been demonstrated when target pharmacokinetic (PK and pharmacodynamic (PD indices for various classes of antimicrobials were achieved to maximise antibiotic activity. Dosing optimisation requires a good knowledge of PK/PD principles. This review serves to provide a foundation in PK/PD principles for the commonly prescribed antibiotics (β-lactams, vancomycin, fluoroquinolones and aminoglycosides, as well as dosing considerations in special populations (critically ill and obese patients. PK principles determine whether an appropriate dose of antimicrobial reaches the intended pathogen(s. It involves the fundamental processes of absorption, distribution, metabolism and elimination, and is affected by the antimicrobial's physicochemical properties. Antimicrobial pharmacodynamics define the relationship between the drug concentration and its observed effect on the pathogen. The major indicator of the effect of the antibiotics is the minimum inhibitory concentration. The quantitative relationship between a PK and microbiological parameter is known as a PK/PD index, which describes the relationship between dose administered and the rate and extent of bacterial killing. Improvements in clinical outcomes have been observed when antimicrobial agents are dosed optimally to achieve their respective PK/PD targets. With the rising rates of antimicrobial resistance and a limited drug development pipeline, PK/PD concepts can foster more rational and individualised dosing regimens, improving outcomes while simultaneously limiting the toxicity of antimicrobials.

  7. Effects of prescription depth, cylinder size, treatment length, tip space, and curved end on doses in high-dose-rate vaginal brachytherapy

    International Nuclear Information System (INIS)

    Li Shidong; Aref, Ibrahim; Walker, Eleanor; Movsas, Benjamin

    2007-01-01

    Purpose: To determine the effects of the prescription depth, cylinder size, treatment length, tip space, and curved end on high-dose-rate vaginal brachytherapy (HDR-VBT) of endometrial cancer. Methods and Materials: Treatment plans were prescribed and optimized based on points at the cylinder surface or at 0.5-cm depth. Cylinder sizes ranging from 2 to 4 cm in diameter, and treatment lengths ranging from 3 to 8 cm were used. Dose points in various depths were precisely defined along the cylinder dome. The given dose and dose uniformity to a depth of interest were measured by the mean dose (MD) and standard deviation (SD), respectively, among the dose points belonging to the depth. Dose fall-off beyond the 0.5 cm treatment depth was determined by the ratio of MD at 0.75-cm depth to MD at 0.5-cm depth. Results: Dose distribution varies significantly with different prescriptions. The surface prescription provides more uniform doses at all depths in the target volume, whereas the 0.5-cm depth prescription creates larger dose variations at the cylinder surface. Dosimetric uncertainty increases significantly (>30%) with shorter tip space. Extreme hot (>150%) and cold spots (<60%) occur if no optimization points were placed at the curved end. Conclusions: Instead of prescribing to a depth of 0.5 cm, increasing the dose per fraction and prescribing to the surface with the exact surface points around the cylinder dome appears to be the optimal approach

  8. Nephrology comanagement and the quality of antibiotic prescribing in primary care for patients with chronic kidney disease: a retrospective cross-sectional study.

    Science.gov (United States)

    Zhu, Justin X G; Nash, Danielle M; McArthur, Eric; Farag, Alexandra; Garg, Amit X; Jain, Arsh K

    2018-04-12

    In primary care, patients with chronic kidney disease (CKD) are frequently prescribed excessive doses of antibiotics relative to their kidney function. We examined whether nephrology comanagement is associated with improved prescribing in primary care. In a retrospective propensity score-matched cross-sectional study, we studied the appropriateness of antibiotic prescriptions by primary care physicians to Ontarians ≥66 years of age with CKD Stages 4 and 5 (estimated glomerular filtration rate <30 mL/min/1.73 m2 not receiving dialysis) from 1 April 2003 to 31 March 2014. Comanagement was defined as having at least one outpatient visit with a nephrologist within the year prior to antibiotic prescription date. We compared the rate of appropriately dosed antibiotics in primary care between 3937 patients who were comanaged by a nephrologist and 3937 patients who were not. Only 1184 (30%) of 3937 noncomanaged patients had appropriately dosed antibiotic prescriptions prescribed by a primary care physician. Nephrology comanagement was associated with an increased likelihood that an appropriately dosed prescription was prescribed by a primary care physician; however, the magnitude of the effect was modest [1342/3937 (34%); odds ratio 1.20 (95% confidence interval 1.09-1.32); P < 0.001]. The majority of antibiotics prescribed by primary care physicians are inappropriately dosed in CKD patients, whether or not a nephrologist is comanaging the patient. Nephrologists have an opportunity to increase awareness of appropriate dosing of medications in primary care through the patients they comanage.

  9. Determination of the optimal minimum radioiodine dose in patients with Graves' disease: a clinical outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, D.; Tan, P.; Booker, J. [Pacific Medical Imaging, Newcastle, NSW (Australia); Epstein, M. [Dept. of Endocrinology, John Hunter Hospital, Newcastle, NSW (Australia); Lan, L. [High-Dependency Unit, St. George Hospital, Sydney, NSW (Australia)

    2001-10-01

    The study was performed under the auspices of the International Atomic Energy Commission, Vienna, Austria, with the aim of determining the optimal minimum therapeutic dose of iodine-131 for Graves' disease. The study was designed as a single-blinded randomised prospective outcome trial. Fifty-eight patients were enrolled, consisting of 50 females and 8 males aged from 17 to 75 years. Each patient was investigated by clinical assessment, biochemical and immunological assessment, thyroid ultrasound, technetium-99m thyroid scintigraphy and 24-h thyroid {sup 131}I uptake. Patients were then randomised into two treatment groups, one receiving 60 Gy and the other receiving 90 Gy thyroid tissue absorbed dose of radioiodine. The end-point markers were clinical and biochemical response to treatment. The median follow-up period was 37.5 months (range, 24-48 months). Among the 57 patients who completed final follow-up, a euthyroid state was achieved in 26 patients (46%), 27 patients (47%) were rendered hypothyroid and four patients (7%) remained hyperthyroid. Thirty-four patients (60%) remained hyperthyroid at 6 months after the initial radioiodine dose (median dose 126 MBq), and a total of 21 patients required additional radioiodine therapy (median total dose 640 MBq; range 370-1,485 MBq). At 6-month follow-up, of the 29 patients who received a thyroid tissue dose of 90 Gy, 17 (59%) remained hyperthyroid. By comparison, of the 28 patients who received a thyroid tissue dose of 60 Gy, 17 (61%) remained hyperthyroid. No significant difference in treatment response was found (P=0.881). At 6 months, five patients in the 90-Gy group were hypothyroid, compared to two patients in the 60-Gy group (P=0.246). Overall at 6 months, non-responders to low-dose therapy had a significantly larger thyroid gland mass (respective means: 35.9 ml vs 21.9 ml) and significantly higher levels of serum thyroglobulin (respective means: 597.6 {mu}g/l vs 96.9 {mu}g/l). Where low-dose radioiodine

  10. Controlled trial of pharmacist intervention in general practice: the effect on prescribing costs.

    Science.gov (United States)

    Rodgers, S; Avery, A J; Meechan, D; Briant, S; Geraghty, M; Doran, K; Whynes, D K

    1999-09-01

    It has been suggested that the employment of pharmacists in general practice might moderate the growth in prescribing costs. However, empirical evidence for this proposition has been lacking. We report the results of a controlled trial of pharmacist intervention in United Kingdom general practice. To determine whether intervention practices made savings relative to controls. An evaluation of an initiative set up by Doncaster Health Authority. Eight practices agreed to take part and received intensive input from five pharmacists for one year (September 1996 to August 1997) at a cost of 163,000 Pounds. Changes in prescribing patterns were investigated by comparing these practices with eight individually matched controls for both the year of the intervention and the previous year. Prescribing data (PACTLINE) were used to assess these changes. The measures used to take account of differences in the populations of the practices included the ASTRO-PU for overall prescribing and the STAR-PU for prescribing in specific therapeutic areas. Differences between intervention and control practices were subjected to Wilcoxon matched-pairs, signed-ranks tests. The median (minimum to maximum) rise in prescribing costs per ASTRO-PU was 0.85 Pound (-1.95 Pounds to 2.05 Pounds) in the intervention practices compared with 2.55 Pounds (1.74 Pounds to 4.65 Pounds) in controls (P = 0.025). Had the cost growth of the intervention group been as high as that of the controls, their total prescribing expenditure would have been around 347,000 Pounds higher. This study suggests that the use of pharmacists did control prescribing expenditure sufficiently to offset their employment costs.

  11. Minimum effective local anesthetic dose of intrathecal hyperbaric ropivacaine and bupivacaine for cesarean section

    Institute of Scientific and Technical Information of China (English)

    GENG Zhi-yu; WANG Dong-xin; WU Xin-min

    2011-01-01

    Background Intrathecal anesthesia is commonly used for cesarean section. Bupivacaine and ropivacaine have all been used as intrathecal drugs. The minimum effective local anesthetic dose (MLAD) of intrathecal ropivacaine for nonobstetric patients has been reported. However, few data are available on the MLAD of hyperbaric ropivacine for obstetric patients and the relative potency to bupivacaine has not been fully determined. In this study, we sought to determine the MLAD of intrathecal ropivacaine and bupivacaine for elective cesarean section and to define their relative potency ratio.Methods We enrolled forty parturients undergoing elective cesarean section under combined spinal-epidural anesthesia and randomized them to one of two groups to receive intrathecal 0.5% hyperbaric ropivacaine or bupivacaine.The initial dose was 10 mg, and was increased in increments of 1 mg, using the technique of up-down sequential allocation. Efficacy was accepted if adequate sensory dermatomal anesthesia to pin prick to T7 or higher was attained within 20 minutes after intrathecal injection, and required no supplementary epidural injection for procedure until at least 50 minutes after the intrathecal injection.Results The intrathecal MLAD was 9.45 mg (95%confidence interval (CI), 8.45-10.56 mg) for ropivacaine and 7.53 mg (95%CI, 7.00-8.10 mg) for bupivacaine. The relative potency ratio was 0.80 (95% Cl, 0.74-0.85) for ropivacaine/bupivacaine when given intrathecally in cesarean section.Conclusion Ropivacaine is 20% less potent than bupivacaine during intrathecal anesthesia for cesarean delivery.

  12. Dose absorbed in the fetus by radioactive drugs prescribed

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.; Di Trano, J.L.

    1998-01-01

    This work aims to review existing guidelines on the hypothesis that must be taken into account when calculating impact from the dose on the fetus for widely employed radioactive drugs. Recent research is added giving data on placenta transference linked to pregnancy term. The most widely used diagnostic and therapeutic practices are analyzed comparing the dose impact on the fetus with limits internationally accepted. This will allow having the necessary tools to answer questions concerning radiological risks due to the administration of radioactive drugs to pregnant women

  13. 78 FR 30782 - Avocados Grown in South Florida; Change in Minimum Grade Requirements

    Science.gov (United States)

    2013-05-23

    ..., regardless of market destination. However, maintaining the current minimum grade requirement for avocados... Service 7 CFR Part 915 [Doc. No. AMS-FV-12-0067; FV13-915-1 PR] Avocados Grown in South Florida; Change in... prescribed under the Florida avocado marketing order (order). The order regulates the handling of avocados...

  14. Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients

    International Nuclear Information System (INIS)

    Gervaise, A.; Pernin, M.; Naulet, P.; Portron, Y.; Lapierre-Combes, M.; Esperabe-Vignau, F.

    2011-01-01

    Purpose: To evaluate the knowledge of physicians prescribing CT examinations on the radiation protection of patients. Materials and methods: A questionnaire was distributed to all clinicians on medical staff who prescribe CT examinations. Several questions related to their prescription pattern and their knowledge of radiation protection. Results: Forty-four questionnaires were analyzed. While 70% of physicians claimed that they considered the risks from exposure to ionizing radiation when prescribing a CT examination, only 25% informed their patients about those risks. Knowledge of the radiation dose delivered during CT evaluation of the abdomen and pelvis was poorly understood and the risks related to small doses of radiation were grossly underestimated. Finally, only a third of clinicians had received training with regards to radiation protection. Conclusion: While most clinicians claim that they consider the risks from exposure to ionizing radiation when prescribing a CT examination, the risks are either not well known or not known at all. Increased formation of clinicians with regards to the radiation protection of patients, maybe through a dedicated clinical rotation while in medical school, could be a solution to improve the knowledge of hospital clinicians with regards to radiation protection. (authors)

  15. Unit of measurement used and parent medication dosing errors.

    Science.gov (United States)

    Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L

    2014-08-01

    Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.

  16. submitter Dose prescription in carbon ion radiotherapy: How to compare two different RBE-weighted dose calculation systems

    CERN Document Server

    Molinelli, Silvia; Mairani, Andrea; Matsufuji, Naruhiro; Kanematsu, Nobuyuki; Inaniwa, Taku; Mirandola, Alfredo; Russo, Stefania; Mastella, Edoardo; Hasegawa, Azusa; Tsuji, Hiroshi; Yamada, Shigeru; Vischioni, Barbara; Vitolo, Viviana; Ferrari, Alfredo; Ciocca, Mario; Kamada, Tadashi; Tsujii, Hirohiko; Orecchia, Roberto; Fossati, Piero

    2016-01-01

    Background and purpose: In carbon ion radiotherapy (CIRT), the use of different relative biological effectiveness (RBE) models in the RBE-weighted dose $(D_{RBE})$ calculation can lead to deviations in the physical dose $(D_{phy})$ delivered to the patient. Our aim is to reduce target $D_{phy}$ deviations by converting prescription dose values. Material and methods: Planning data of patients treated at the National Institute of Radiological Sciences (NIRS) were collected, with prescribed doses per fraction ranging from 3.6 Gy (RBE) to 4.6 Gy (RBE), according to the Japanese semi-empirical model. The $D_{phy}$ was Monte Carlo (MC) re-calculated simulating the NIRS beamline. The local effect model (LEM)_I was then applied to estimate $D_{RBE}$. Target median $D_{RBE}$ ratios between MC + LEM_I and NIRS plans determined correction factors for the conversion of prescription doses. Plans were re-optimized in a LEM_I-based commercial system, prescribing the NIRS uncorrected and corrected $D_{RBE}$. Results: The MC ...

  17. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  18. To prescribe codeine or not to prescribe codeine?

    Science.gov (United States)

    Fleming, Marc L; Wanat, Matthew A

    2014-09-01

    A recently published study in Pediatrics by Kaiser et al. (2014; Epub April 21, DOI: 10.1542/peds.2013-3171) reported that on average, over the past decade, children aged 3 to 17 were prescribed approximately 700,000 prescriptions for codeine-containing products each year in association with emergency department (ED) visits. Although, guidelines from the American Academy of Pediatrics issued warnings in 1997 and reaffirmed their concerns regarding the safety and effectiveness of codeine in 2006, it is still often prescribed for pain and cough associated with upper respiratory infection. With the impending rescheduling of hydrocodone combination products to Schedule II, physicians and mid-level prescribers may be compelled to prescribe codeine-containing products (e.g., with acetaminophen) due to reduced administrative burden and limits on Schedule II prescriptive authority for nurse practitioners and physician assistants in some states. This commentary expounds on the safety and effectiveness concerns of codeine, with a primary focus on patients in the ED setting.

  19. The use of paracetamol (acetaminophen) among a community sample of people with chronic non-cancer pain prescribed opioids.

    Science.gov (United States)

    Hoban, B; Larance, B; Gisev, N; Nielsen, S; Cohen, M; Bruno, R; Shand, F; Lintzeris, N; Hall, W; Farrell, M; Degenhardt, L

    2015-11-01

    The regular use of simple analgesics in addition to opioids such as paracetamol (or acetaminophen) is recommended for persistent pain to enhance analgesia. Few studies have examined the frequency and doses of paracetamol among people with chronic non-cancer pain including use above the recommended maximum daily dose. To assess (i) the prevalence of paracetamol use among people with chronic non-cancer pain prescribed opioids, (ii) assess the prevalence of paracetamol use above the recommended maximum daily dose and (iii) assess correlates of people who used paracetamol above the recommended maximum daily dose including: age, gender, income, education, pain severity and interference, use of paracetamol/opioid combination analgesics, total opioid dose, depression, anxiety, pain self-efficacy or comorbid substance use, among people prescribed opioids for chronic non-cancer pain. This study draws on baseline data collected for the Pain and Opioids IN Treatment (POINT) study and utilises data from 962 interviews and medication diaries. The POINT study is national prospective cohort of people with chronic non-cancer pain prescribed opioids. Participants were recruited from randomly selected pharmacies across Australia. Sixty-three per cent of the participants had used paracetamol in the past week (95% CI = 59.7-65.8). Among the paracetamol users 22% (95% CI = 19.3-24.6) had used paracetamol/opioid combination analgesics and 4.8% (95% CI = 3.6-6.3) had used paracetamol above the recommended maximum daily dose (i.e. > 4000 mg/day). Following binomial logistic regression (χ(2) = 25.98, df = 10, p = 0.004), people who had taken above the recommended maximum daily dose were less likely to have low income (AOR = 0.52, 95% CI = 0.27-0.99), more likely to use paracetamol/opioid combination analgesics (AOR = 2.01, 95% CI = 1.02-3.98) and more likely to take a higher opioid dose (AOR = 1.00, 95% CI = 1.00-1.01). The majority of people with chronic non-cancer pain prescribed

  20. Application of a Novel Dose-Uncertainty Model for Dose-Uncertainty Analysis in Prostate Intensity-Modulated Radiotherapy

    International Nuclear Information System (INIS)

    Jin Hosang; Palta, Jatinder R.; Kim, You-Hyun; Kim, Siyong

    2010-01-01

    Purpose: To analyze dose uncertainty using a previously published dose-uncertainty model, and to assess potential dosimetric risks existing in prostate intensity-modulated radiotherapy (IMRT). Methods and Materials: The dose-uncertainty model provides a three-dimensional (3D) dose-uncertainty distribution in a given confidence level. For 8 retrospectively selected patients, dose-uncertainty maps were constructed using the dose-uncertainty model at the 95% CL. In addition to uncertainties inherent to the radiation treatment planning system, four scenarios of spatial errors were considered: machine only (S1), S1 + intrafraction, S1 + interfraction, and S1 + both intrafraction and interfraction errors. To evaluate the potential risks of the IMRT plans, three dose-uncertainty-based plan evaluation tools were introduced: confidence-weighted dose-volume histogram, confidence-weighted dose distribution, and dose-uncertainty-volume histogram. Results: Dose uncertainty caused by interfraction setup error was more significant than that of intrafraction motion error. The maximum dose uncertainty (95% confidence) of the clinical target volume (CTV) was smaller than 5% of the prescribed dose in all but two cases (13.9% and 10.2%). The dose uncertainty for 95% of the CTV volume ranged from 1.3% to 2.9% of the prescribed dose. Conclusions: The dose uncertainty in prostate IMRT could be evaluated using the dose-uncertainty model. Prostate IMRT plans satisfying the same plan objectives could generate a significantly different dose uncertainty because a complex interplay of many uncertainty sources. The uncertainty-based plan evaluation contributes to generating reliable and error-resistant treatment plans.

  1. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  2. Rationalising prescribing

    DEFF Research Database (Denmark)

    Wadmann, Sarah; Bang, Lia Evi

    2015-01-01

    Initiatives in the name of 'rational pharmacotherapy' have been launched to alter what is seen as 'inappropriate' prescribing practices of physicians. Based on observations and interviews with 20 general practitioners (GPs) in 2009-2011, we explored how attempts to rationalise prescribing interac...

  3. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  4. General practitioner attitudes towards prescribing aspirin to carriers of Lynch Syndrome: findings from a national survey.

    Science.gov (United States)

    Smith, Samuel G; Foy, Robbie; McGowan, Jennifer; Kobayashi, Lindsay C; Burn, John; Brown, Karen; Side, Lucy; Cuzick, Jack

    2017-10-01

    A dose non-inferiority study comparing 100 mg, 300 mg and 600 mg of aspirin for cancer prevention among Lynch Syndrome carriers is underway (Colorectal Adenoma/Carcinoma Prevention Programme trial 3, CaPP3). To guide implementation of the findings, we investigated general practitioner (GP) attitudes towards aspirin prescribing for Lynch Syndrome carriers. We surveyed 1007 UK GPs (9.6% response rate). Using a within-subjects design, GPs read a statement on harms and benefits of aspirin and indicated their willingness to prescribe aspirin at three doses (100 mg, 300 mg, 600 mg). Approximately two-thirds (70.8%) of GPs had heard of Lynch Syndrome or its associated names, and among those 46.7% were aware of the cancer preventive effects of aspirin among carriers. Two-thirds (68.1%) of GPs reported feeling comfortable discussing harms and benefits of aspirin with a Lynch Syndrome patient. Willingness to prescribe was 91.3% at 100 mg, and declined to 81.8% at 300 mg and 62.3% at 600 mg (p Lynch Syndrome patient in practice (OR 1.44, 95% CI 1.01-2.05, p = 0.045). GPs report limited awareness of Lynch Syndrome and the preventive effects of aspirin among carriers. To ensure the optimal dose identified in the CaPP3 trial is readily available to patients, prescribing guidance and strategies to educate GPs should be developed.

  5. Methotrexate osteopathy in long-term, low-dose methotrexate treatment for psoriasis and rheumatoid arthritis

    NARCIS (Netherlands)

    Zonneveld, I. M.; Bakker, W. K.; Dijkstra, P. F.; Bos, J. D.; van Soesbergen, R. M.; Dinant, H. J.

    1996-01-01

    In dermatology and rheumatology, methotrexate is frequently prescribed in low dosages per week; in oncology, high dosages per week are prescribed. Methotrexate osteopathy was first reported in children with leukemia treated with high doses of methotrexate. In animal studies, low doses of

  6. The impact of pharmacy services on opioid prescribing in dental practice.

    Science.gov (United States)

    Stewart, Autumn; Zborovancik, Kelsey J; Stiely, Kara L

    To compare rates of dental opioid prescribing between periods of full and partial integration of pharmacy services and periods of no integration. This observational study used a retrospective chart review of opioid prescriptions written by dental providers practicing in a free dental clinic for the medically underserved over a period of 74 months. Pharmacy services were fully integrated into the practice model for 48 of the 74 months under study. During this time frame, all dental opioid orders required review by the pharmacy department before prescribing. Outcomes related to prescribing rates and errors were compared between groups, which were defined by the level of integrated pharmacy services. Demographic and prescription-specific data (drug name, dose, quantity, directions, professional designation of individual entering order) and clinic appointment data were collected and analyzed with the use of descriptive and inferential statistics. A total of 102 opioids were prescribed to 89 patients; hydrocodone-acetaminophen combination products were the most frequently used. Opioid prescribing rates were 5 times greater when pharmacy services were not integrated (P dental practice. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  8. [Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients].

    Science.gov (United States)

    Gervaise, A; Esperabe-Vignau, F; Pernin, M; Naulet, P; Portron, Y; Lapierre-Combes, M

    2011-01-01

    To evaluate the knowledge of physicians prescribing CT examinations on the radiation protection of patients. A questionnaire was distributed to all clinicians on medical staff who prescribe CT examinations. Several questions related to their prescription pattern and their knowledge of radiation protection. Forty-four questionnaires were analyzed. While 70% of physicians claimed that they considered the risks from exposure to ionizing radiation when prescribing a CT examination, only 25% informed their patients about those risks. Knowledge of the radiation dose delivered during CT evaluation of the abdomen and pelvis was poorly understood and the risks related to small doses of radiation were grossly underestimated. Finally, only a third of clinicians had received training with regards to radiation protection. While most clinicians claim that they consider the risks from exposure to ionizing radiation when prescribing a CT examination, the risks are either not well known or not known at all. Increased formation of clinicians with regards to the radiation protection of patients, maybe through a dedicated clinical rotation while in medical school, could be a solution to improve the knowledge of hospital clinicians with regards to radiation protection. Copyright © 2011 Elsevier Masson SAS and Éditions françaises de radiologie. All rights reserved.

  9. Target dose study of effects of changes in the AAA calculation resolution on lung SABR plan

    International Nuclear Information System (INIS)

    Kim, Dae Il; Son, Sang Jun; Ahn, Bum Seok; Jung, Chi Hoon; Yoo, Suk Hyun

    2014-01-01

    Changing the calculation grid of AAA in Lung SABR plan and to analyze the changes in target dose, and investigated the effects associated with it, and considered a suitable method of application. 4D CT image that was used to plan all been taken with Brilliance Big Bore CT (Philips, Netherlands) and in Lung SABR plan(Eclipse TM ver10.0.42, Varian, the USA), use anisotropic analytic algorithm(AAA, ver.10, Varian Medical Systems, Palo Alto, CA, USA) and, was calculated by the calculation grid 1.0, 3.0, 5.0 mm in each Lung SABR plan. Lung SABR plan of 10 cases are using each of 1.0 mm, 3.0 mm, 5.0 mm calculation grid, and in case of use a 1.0 mm calculation grid V98 of the prescribed dose is about 99.5%±1.5%, Dmin of the prescribed dose is about 92.5±1.5% and Homogeneity Index(HI) is 1.0489±0.0025. In the case of use a 3.0 mm calculation grid V98 dose of the prescribed dose is about 90±4.5% , Dmin of the prescribed dose is about 87.5±3% and HI is about 1.07±1. In the case of use a 5.0 mm calculation grid V98 dose of the prescribed dose is about 63±15%, Dmin of the prescribed dose is about 83±4% and HI is about 1.13±0.2, respectively. The calculation grid of 1.0 mm is better improves the accuracy of dose calculation than using 3.0 mm and 5.mm, although calculation times increase in the case of smaller PTV relatively. As lung, spread relatively large and low density and small PTV, it is considered and good to use a calculation grid of 1.0 mm

  10. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  11. Evaluation of the appropriate use of commonly prescribed fluoroquinolones and the risk of dysglycemia

    Science.gov (United States)

    Kabbara, Wissam K; Ramadan, Wijdan H; Rahbany, Peggy; Al-Natour, Souhaila

    2015-01-01

    Background Fluoroquinolones are among the most widely prescribed antibiotics. However, concerns about increasing resistant microorganisms and the risk of dysglycemia associated with the use of these agents have emerged. Objective The primary objective of the study was to evaluate the appropriate use of commonly prescribed fluoroquinolones, including appropriate indication, dose, dose adjustment in renal impairment, and duration of treatment. The secondary objective was to investigate the dysglycemic effect of fluoroquinolone use (hypoglycemia and/or hyperglycemia) in diabetic and nondiabetic patients. Methods A prospective observational study at a teaching hospital in Lebanon was conducted over a 6-month period. A total of 118 patients receiving broad-spectrum fluoroquinolones (levofloxacin, ciprofloxacin, and moxifloxacin) were identified. Patients were mainly recruited from internal medicine floors and intensive care units. Results The final percentage for the appropriate indication, dose, and duration of fluoroquinolone therapy was 93.2%, 74.6%, and 57.6%, respectively. A total of 57.1% of the patients did not receive the appropriate dose adjustment according to their level of renal impairment. In addition, dysglycemia occurred in both diabetic and nondiabetic patients. Dysglycemia was more frequently encountered with ciprofloxacin (50.0%), followed by levofloxacin (42.4%) and moxifloxacin (7.6%). Hyperglycemia was more common than hypoglycemia in all groups. The highest incidence of hyperglycemia occurred with levofloxacin (70.0%), followed by ciprofloxacin (39.0%) and moxifloxacin (33.3%). In contrast, hypoglycemia did not occur in the ciprofloxacin group, but it was more common with moxifloxacin (11.1%) and levofloxacin (6.0%). Conclusion The major clinical interventions for the future will adjust the dose and duration of therapy with commonly prescribed fluoroquinolones. The incidence of hypoglycemia was less common than hyperglycemia. PMID:25960658

  12. Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Calcina, Carmen S Guzman; Almeida, Adelaide de; Rocha, Jose R Oliveira; Abrego, Felipe Chen; Baffa, Oswaldo

    2005-01-01

    Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40)

  13. Modeling of outpatient prescribing process in iran: a gateway toward electronic prescribing system.

    Science.gov (United States)

    Ahmadi, Maryam; Samadbeik, Mahnaz; Sadoughi, Farahnaz

    2014-01-01

    Implementation of electronic prescribing system can overcome many problems of the paper prescribing system, and provide numerous opportunities of more effective and advantageous prescribing. Successful implementation of such a system requires complete and deep understanding of work content, human force, and workflow of paper prescribing. The current study was designed in order to model the current business process of outpatient prescribing in Iran and clarify different actions during this process. In order to describe the prescribing process and the system features in Iran, the methodology of business process modeling and analysis was used in the present study. The results of the process documentation were analyzed using a conceptual model of workflow elements and the technique of modeling "As-Is" business processes. Analysis of the current (as-is) prescribing process demonstrated that Iran stood at the first levels of sophistication in graduated levels of electronic prescribing, namely electronic prescription reference, and that there were problematic areas including bottlenecks, redundant and duplicated work, concentration of decision nodes, and communicative weaknesses among stakeholders of the process. Using information technology in some activities of medication prescription in Iran has not eliminated the dependence of the stakeholders on paper-based documents and prescriptions. Therefore, it is necessary to implement proper system programming in order to support change management and solve the problems in the existing prescribing process. To this end, a suitable basis should be provided for reorganization and improvement of the prescribing process for the future electronic systems.

  14. Effect of fentanyl on the induction dose and minimum infusion rate of propofol preventing movement in dogs.

    Science.gov (United States)

    Davis, Carrie A; Seddighi, Reza; Cox, Sherry K; Sun, Xiaocun; Egger, Christine M; Doherty, Thomas J

    2017-07-01

    To determine the effect of fentanyl on the induction dose of propofol and minimum infusion rate required to prevent movement in response to noxious stimulation (MIR NM ) in dogs. Crossover experimental design. Six healthy, adult intact male Beagle dogs, mean±standard deviation 12.6±0.4 kg. Dogs were administered 0.9% saline (treatment P), fentanyl (5 μg kg -1 ) (treatment PLDF) or fentanyl (10 μg kg -1 ) (treatment PHDF) intravenously over 5 minutes. Five minutes later, anesthesia was induced with propofol (2 mg kg -1 , followed by 1 mg kg -1 every 15 seconds to achieve intubation) and maintained for 90 minutes by constant rate infusions (CRIs) of propofol alone or with fentanyl: P, propofol (0.5 mg kg -1  minute -1 ); PLDF, propofol (0.35 mg kg -1  minute -1 ) and fentanyl (0.1 μg kg -1  minute -1 ); PHDF, propofol (0.3 mg kg -1  minute -1 ) and fentanyl (0.2 μg kg -1  minute -1 ). Propofol CRI was increased or decreased based on the response to stimulation (50 V, 50 Hz, 10 mA), with 20 minutes between adjustments. Data were analyzed using a mixed-model anova and presented as mean±standard error. ropofol induction doses were 6.16±0.31, 3.67±0.21 and 3.33±0.42 mg kg -1 for P, PLDF and PHDF, respectively. Doses for PLDF and PHDF were significantly decreased from P (pFentanyl, at the doses studied, caused statistically significant and clinically important decreases in the propofol induction dose and MIR NM . Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  15. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  16. Dose-volume analysis for quality assurance of interstitial brachytherapy for breast cancer

    International Nuclear Information System (INIS)

    Vicini, Frank A.; Kestin, Larry L.; Edmundson, Gregory K.; Jaffray, David A.; Wong, John W.; Kini, Vijay R.; Chen, Peter Y.; Martinez, Alvaro A.

    1999-01-01

    11-18). Despite visual verification by the treating physician that surgical clips (with an appropriate margin) were within the boundaries of the implant needles, the median proportion of the lumpectomy cavity that received the prescribed dose was only 87% (range 73-98%). With respect to the target volume, a median of only 68% (range 56-81%) of this volume received 100% of the prescribed dose. On average, the minimum dose received by at least 90% of the target volume was 22 Gy (range 17.3-26.9), which corresponds to 69% of the prescribed dose. Conclusion: Preliminary results using our new technique to evaluate implant quality with CT-based 3D dose-volume analysis appear promising. Dosimetric quality and target volume coverage can be concurrently analyzed, allowing the possibility of evaluating implants prospectively. Considering that target volume coverage may be suboptimal even after radiographically verifying accurate implant placement, techniques similar to this need to be developed to ultimately determine the true efficacy of brachytherapy in the management of breast cancer

  17. Understanding the determinants of antimicrobial prescribing within hospitals: the role of "prescribing etiquette".

    Science.gov (United States)

    Charani, E; Castro-Sanchez, E; Sevdalis, N; Kyratsis, Y; Drumright, L; Shah, N; Holmes, A

    2013-07-01

    There is limited knowledge of the key determinants of antimicrobial prescribing behavior (APB) in hospitals. An understanding of these determinants is required for the successful design, adoption, and implementation of quality improvement interventions in antimicrobial stewardship programs. Qualitative semistructured interviews were conducted with doctors (n = 10), pharmacists (n = 10), and nurses and midwives (n = 19) in 4 hospitals in London. Interviews were conducted until thematic saturation was reached. Thematic analysis was applied to the data to identify the key determinants of antimicrobial prescribing behaviors. The APB of healthcare professionals is governed by a set of cultural rules. Antimicrobial prescribing is performed in an environment where the behavior of clinical leaders or seniors influences practice of junior doctors. Senior doctors consider themselves exempt from following policy and practice within a culture of perceived autonomous decision making that relies more on personal knowledge and experience than formal policy. Prescribers identify with the clinical groups in which they work and adjust their APB according to the prevailing practice within these groups. A culture of "noninterference" in the antimicrobial prescribing practice of peers prevents intervention into prescribing of colleagues. These sets of cultural rules demonstrate the existence of a "prescribing etiquette," which dominates the APB of healthcare professionals. Prescribing etiquette creates an environment in which professional hierarchy and clinical groups act as key determinants of APB. To influence the antimicrobial prescribing of individual healthcare professionals, interventions need to address prescribing etiquette and use clinical leadership within existing clinical groups to influence practice.

  18. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  19. Monte-Carlo Method Python Library for dose distribution Calculation in Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Randriantsizafy, R D; Ramanandraibe, M J [Madagascar Institut National des Sciences et Techniques Nucleaires, Antananarivo (Madagascar); Raboanary, R [Institut of astro and High-Energy Physics Madagascar, University of Antananarivo, Antananarivo (Madagascar)

    2007-07-01

    The Cs-137 Brachytherapy treatment is performed in Madagascar since 2005. Time treatment calculation for prescribed dose is made manually. Monte-Carlo Method Python library written at Madagascar INSTN is experimentally used to calculate the dose distribution on the tumour and around it. The first validation of the code was done by comparing the library curves with the Nucletron company curves. To reduce the duration of the calculation, a Grid of PC's is set up with listner patch run on each PC. The library will be used to modelize the dose distribution in the CT scan patient picture for individual and better accuracy time calculation for a prescribed dose.

  20. Monte-Carlo Method Python Library for dose distribution Calculation in Brachytherapy

    International Nuclear Information System (INIS)

    Randriantsizafy, R.D.; Ramanandraibe, M.J.; Raboanary, R.

    2007-01-01

    The Cs-137 Brachytherapy treatment is performed in Madagascar since 2005. Time treatment calculation for prescribed dose is made manually. Monte-Carlo Method Python library written at Madagascar INSTN is experimentally used to calculate the dose distribution on the tumour and around it. The first validation of the code was done by comparing the library curves with the Nucletron company curves. To reduce the duration of the calculation, a Grid of PC's is set up with listner patch run on each PC. The library will be used to modelize the dose distribution in the CT scan patient picture for individual and better accuracy time calculation for a prescribed dose.

  1. The minimum measurable dose of CaF{sub 2}:Dy measured via an improved heating profile with an automatic 6600 thermoluminescent detector

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shachar, B; Weinstein, M; German, U [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    One of the advantages of the thermoluminescent method is its ability to measure low doses, which is useful in environmental dosimetry, as well as in archaeology. The CaF{sub 2}:Dy (Crown as TLD-200), has a sensitivity of 10-30 times greater than the sensitivity of TLD-100, when irradiated by Cs-137. In the present work we evaluated the TL-dose response of CaF{sub 2}:Dy, by using an improved heating profile which is giving the main glow peak alone. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses (MMD) were derived. The MMD were calculated by taking 3 times the standard deviation of the unirradiated chips. The results of the TL-dose response, as well as file fee calculated MMD by taxing 3 times the standard deviation of unirradiated chips, measured by file new 6600 automatic thermoluminescent detector, are presented in this work. We received a MMD of about 0.01 mGy (1 mrad), an improvement of a factor of 2.5 relatively to the integral light response evaluation using the standard heating profile (authors).

  2. SU-E-J-174: Adaptive PET-Based Dose Painting with Tomotherapy

    International Nuclear Information System (INIS)

    Darwish, N; Mackie, T; Thomadsen, B

    2014-01-01

    Purpose: PET imaging can be converted into dose prescription directly. Due to the variability of the intensity of PET the image, PET prescription maybe superior over uniform dose prescription. Furthermore, unlike the case in image reconstruction of not knowing the image solution in advance, the prescribed dose is known from a PET image a priori. Therefore, optimum beam orientations are derivable. Methods: We can assume the PET image to be the prescribed dose and invert it to determine the energy fluence. The same method used to reconstruct tissue images from projections could be used to solve the inverse problem of determining beam orientations and modulation patterns from a dose prescription [10]. Unlike standard tomographic reconstruction of images from measured projection profiles, the inversion of the prescribed dose results in photon fluence which may be negative and therefore unphysical. Two-dimensional modulated beams can be modelled in terms of the attenuated or exponential radon transform of the prescribed dose function (assumed to be the PET image in this case), an application of a Ram-Lak filter, and inversion by backprojection. Unlike the case in PET processing, however, the filtered beam obtained from the inversion represents a physical photon fluence. Therefore, a positivity constraint for the fluence (setting negative fluence to zero) must be applied (Brahme et al 1982, Bortfeld et al 1990) Results: Truncating the negative profiles from the PET data results in an approximation of the derivable energy fluence. Backprojection of the deliverable fluence is an approximation of the dose delivered. The deliverable dose is comparable to the original PET image and is similar to the PET image. Conclusion: It is possible to use the PET data or image as a direct indicator of deliverable fluence for cylindrical radiotherapy systems such as TomoTherapy

  3. Learning from prescribing errors

    OpenAIRE

    Dean, B

    2002-01-01

    

 The importance of learning from medical error has recently received increasing emphasis. This paper focuses on prescribing errors and argues that, while learning from prescribing errors is a laudable goal, there are currently barriers that can prevent this occurring. Learning from errors can take place on an individual level, at a team level, and across an organisation. Barriers to learning from prescribing errors include the non-discovery of many prescribing errors, lack of feedback to th...

  4. The effect of electronic medical record system use on communication between pharmacists and prescribers.

    Science.gov (United States)

    Singer, Alexander; Duarte Fernandez, Roberto

    2015-10-28

    The Electronic Medical Record (EMR) is becoming increasingly common in health care settings. Research shows that EMRs have the potential to reduce instances of medication errors and improve communication between pharmacists and prescribers; however, more research is required to demonstrate whether this is true. This study aims to determine the effect of a newly implemented EMR system on communication between pharmacists and primary care clinicians. A retrospective chart analysis of primary care EMR data comparing faxed pharmacy communications captured before and after the implementation of an EMR system at an academic family medicine clinic. Communication requests were classified into the following various categories: refill accepted, refill denied, clarification, incorrect dose, interaction, drug insurance/coverage application, new prescription request, supplies request, continued care information, duplicate fax substitution, opioid early release request, confirmation by phone call, and other. The number and percentage of clarification requests, interaction notifications, and incorrect dose notifications were lower after the implementation of the EMR system. The number and percentage of refills accepted and new prescription requests increased after the implementation of the EMR system. The implementation of an EMR in an academic family medicine clinic had a significant effect on the volume of communication between pharmacists and prescribers. The amount of clarification requests and incorrect dosing communications decreased after EMR implementation. This suggests that EMRs improve prescribing safety. The increased amount of refills accepted and new prescription requests post EMR implementation suggests that the EMR is capable of changing prescription patterns.

  5. The survey of the surface doses of the dental x-ray machines

    International Nuclear Information System (INIS)

    Lee, Jae Seo; Kang, Byung Cheol; Yoon, Suk Ja

    2005-01-01

    The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-S (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study. Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instrument, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surfaces doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  6. Impact of a clinical guideline for prescribing antibiotics to inpatients reporting penicillin or cephalosporin allergy.

    Science.gov (United States)

    Blumenthal, Kimberly G; Shenoy, Erica S; Varughese, Christy A; Hurwitz, Shelley; Hooper, David C; Banerji, Aleena

    2015-10-01

    Self-reported penicillin allergy infrequently reflects an inability to tolerate penicillins. Inpatients reporting penicillin allergy receive alternative antibiotics that might be broader spectrum, more toxic, or less effective. To develop and assess a clinical guideline for the general inpatient provider that directs taking a history and prescribing antibiotics for patients with penicillin or cephalosporin allergy. A guideline was implemented to assist providers with assessing allergy history and prescribing antibiotics for patients with reported penicillin or cephalosporin allergy. The guideline used a standard 2-step graded challenge or test dose. A quasi-experimental study was performed to assess safety, feasibility, and impact on antibiotic use by comparing treatment 21 months before guideline implementation with 12 months after guideline implementation. Significantly more test doses to β-lactam antibiotics were performed monthly after vs before guideline implementation (median 14.5, interquartile range 13-16.25, vs 2, interquartile range 1-3.25, P  .5) between periods. Guideline-driven test doses decreased alternative antimicrobial therapy after the test dose, including vancomycin (68.3% vs 37.2%, P penicillin or cephalosporin allergy was associated with an almost 7-fold increase in the number of test doses to β-lactams without increased adverse drug reactions. Patients assessed with guideline-driven test doses were observed to have significantly decreased alternative antibiotic exposure. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. [Temporary recommendation for use on off-label baclofen: viewpoint of Prescribers of the CAMTEA system].

    Science.gov (United States)

    Rolland, Benjamin; Deheul, Sylvie; Danel, Thierry; Bence, Camille; Blanquart, Marie-Christine; Bonord, Alexandre; Semal, Robin; Briand, Thierry; Sochala, Michel; Dubocage, Christelle; Dupriez, François; Duquesne, Damien; Gibour, Bernard; Loosfeld, Xavier; Henebelle, Dorothée; Henon, Michael; Vernalde, Elodie; Matton, Christian; Bacquet, Jean-Eudes; Molmy, Lucie; Sarasy, François; Simioni, Nicolas; Richez, Cécile; Gentil-Spinosi, Laure; Vosgien, Véronique; Yguel, Jacques; Ledent, Thierry; Auffret, Marine; Wilquin, Maroussia; Ziolkowski, Danièle; Sochala, Michel; Gautier, Sophie; Bordet, Régis; Cottencin, Olivier

    2015-01-01

    The use of high dose baclofen for alcohol-dependence emerged in France from 2008 based on empirical findings, and is still off-label. However, due to the rapid increase in this prescribing practice, the French health authorities have decided to frame it using an extraordinary regulatory measure named "temporary recommendation for use" (TRU). Baclofen prescribers from CAMTEA, a regional team-based off-label system for supervising baclofen prescribing, which was developed much prior to the TRU, discuss herein the pros and cons of this measure and the applicability of its different aspects in the daily clinical practice. © 2014 Société Française de Pharmacologie et de Thérapeutique.

  8. Evaluation of lens dose in medulloblastoma radiotherapy

    International Nuclear Information System (INIS)

    Oliveira, F.L.; Vilela, E.C.; Sousa, S.A; Lima, F.F. de

    2007-01-01

    The improvement of the applied radiotherapy techniques in the cranial-spinal therapy, which is used in the cases of medulloblastoma, aims the reduction of the risks of future damages in enclosed critical agencies in the irradiation fields. This work aims to evaluate the lens doses due two common techniques used in medulloblastoma radiotherapy. For this, thermoluminescent dosimeters, previously calibrated, were located in an anthropomorphic phantom (ALDERSON - RANDON Laboratory), in the tumor and lens positions. The employed techniques were as following: (1) angled fields technique and (2) half-beam block technique. The phantom was irradiated five times in each technique with two lateral opposed fields in the brain with a total prescribed dose of 1.5 Gy, followed of two posterior spinal fields with the same prescribed dose, using a 6MV accelerator. The results showed that the doses in the first technique were 0.10 +- 0,04 Gy and, in second one, 0.09 +- 0,02 Gy. It was observed that, independent of the employed technique, the lens doses practically are the same. (author)

  9. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    Science.gov (United States)

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  10. Improved consistency in dosing anti-tuberculosis drugs in Taipei, Taiwan.

    Science.gov (United States)

    Chiang, Chen-Yuan; Yu, Ming-Chih; Shih, Hsiu-Chen; Yen, Muh-Yong; Hsu, Yu-Ling; Yang, Shiang-Lin; Lin, Tao-Ping; Bai, Kuan-Jen

    2012-01-01

    It was reported that 35.5% of tuberculosis (TB) cases reported in 2003 in Taipei City had no recorded pre-treatment body weight and that among those who had, inconsistent dosing of anti-TB drugs was frequent. Taiwan Centers for Disease Control (CDC) have taken actions to strengthen dosing of anti-TB drugs among general practitioners. Prescribing practices of anti-TB drugs in Taipei City in 2007-2010 were investigated to assess whether interventions on dosing were effective. Lists of all notified culture positive TB cases in 2007-2010 were obtained from National TB Registry at Taiwan CDC. A medical audit of TB case management files was performed to collect pretreatment body weight and regimens prescribed at commencement of treatment. Dosages prescribed were compared with dosages recommended. The proportion of patients with recorded pre-treatment body weight was 64.5% in 2003, which increased to 96.5% in 2007-2010 (pTaipei City has remarkably improved after health authorities implemented a series of interventions.

  11. Chinese Herbal Medicines – Comparison of Doses Prescribed in ...

    African Journals Online (AJOL)

    Huan Dong Lu, Beijing 100029, China. *For correspondence: Email: fuyanlingbucm@126.com; Tel: (+86) 10-6428-6307; Fax: (+86) 10-6422-0858 ... pharmacopoeia, accounting for 57.14 % (32/56). The top three factors influencing dose ... herbal combination, property of Chinese herbs, quality of medicinal, have a strong ...

  12. Influence of Routine MV CBCT Usage on Dose Distribution in Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Faj, D.; Kasabasic, M.; Ivkovic, A.; Tomas, I.; Jurkovic, S.

    2013-01-01

    The pelvic radiotherapy is a standard treatment for patients with cervical, uterine and rectal carcinomas. During radiation treatment open tabletop device or bellyboard is used to reduce the side effects of healthy surrounding tissue. Patients are continually adjusting to the bellyboard during the treatment which causes geometrical and dosage uncertainties and influences the results of the treatment. Therefore, to reduce these uncertainties, megavoltage cone-beam computed tomography (MV CBCT) system is used. The objective of this research was to evaluate the image acquisition dose delivered to patients from MV CBCT. MV CBCT imaging was simulated on 15 patients using 3D treatment planning software XiO (CMS Inc., St. Louis, MO). The influence of the routine MV CBCT usage on treatment plan was investigated by analyzing the changes in dose volume histograms, mean values and maximum doses in the planning volumes. Simulations have shown that daily usage of MV CBCT causes differences in the dose volume histograms. Moreover, for every patient mean value exceeded prescribed tolerance (±1% of the prescribed dose) and maximum value exceeded recommended maximum of 107% of the prescribed dose. The results have shown that MV CBCT dose to the patient should be a part of the RT plan.(author)

  13. IAEA/ WHO TLD postal dose intercomparison results in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Bhuiyan, N.U.; Rahman, S.

    2001-01-01

    Full text: For the accurate delivery of prescribed dose to the patients, high precision and accuracy in radiation dosimetry is required. The hospital/medical physicist is responsible for the accurate delivery of whole planned radiation doses to the patients prescribed by the radio therapist. The proper delivery of radiation doses depends upon the accurate output measurements of doses from the therapy machines. In Bangladesh, only six 60 Co units and five deep therapy machines are in use. Some more are expected to be installed soon. Still in 2001, none of the Government radiotherapy centers in Bangladesh was properly equipped with medical physicists as well as radiotherapy dosimetry equipment. Bangladesh Atomic Energy Commission (BAEC) is responsible for radiation safety in Bangladesh and BAEC has assigned Secondary Standard Dosimetry Laboratory (SSDL) of Bangladesh for providing dosimetry calibration to all radiotherapy centers in Bangladesh. The output measurements of therapy machines are performed once in a year by SSDL and the results are compared by participating in the annual TLD postal dose intercomparison program organized by IAEA/WHO SSDL Network. The absorbed dose to water is determined using IAEA dosimetry protocol (TRS 277 and 381) and water phantom of size 30 x 30 x 30 cm 3 , The measurements of SSDL are traceable to NPL of UK. The accuracy achieved in SSDL, Bangladesh has been found better than ± 3.5%, which is within the prescribed limit of dosimetry standard of IAEA. The methodology of output dose measurements in different radiotherapy centers in Bangladesh is described along with the IAEA/WHO intercomparison results

  14. Factors influencing the choice of antidepressants: A study of antidepressant prescribing practice at University psychiatric clinic in Belgrade

    Directory of Open Access Journals (Sweden)

    Marić Nađa P.

    2012-01-01

    Full Text Available Background/Aim. Antidepressants are a widely used class of drugs. The aim of this study was to investigate different aspects of antidepressant prescribing practice at University Psychiatric Clinic in Belgrade. Methods. This cross-sectional study was carried out by retrospective analysis of the patient's medical charts. The study included all patients with antidepressant prescribed at discharge during 2009 (n = 296. The evaluation was focused on patient- related factors (socio-demographic and illness related, psychiatrist-related factors (sex and duration of working experience and drug related factors (type of antidepressant, dose, polypharmacy and reimbursement by national health insurance. Results. Antidepressants were prescribed for unipolar depression (F32-34, ICD X either without comorbidity (46.2% or with comorbidity (24.7%, mostly as a monotherapy (91% had one antidepressant, to the patients who were 65% female, aged 50.1 ± 8.9, most of them with 12 years of education (52.6%, married (69.3% and employed (55.9%. The majority of patients had a history of two hospitalizations (Med 2; 25th-75th perc. 1-4 during nine years (Med 9; 25th-75th perc. 2-15 after the first episode of depression. Among them, 19% were found to be suicidal in a lifetime. The single most prescribed antidepressant was sertraline (20.4%, followed by fluoxetine (13.3% and maprotiline (11.7%. Utilization of antidepressants was positively correlated with the rate of reimbursement (p < 0.01. The most prescribed antidepressant group was selective serotonin reuptake inhibitors (SSRI (47.8%, followed by tricyclic antidepresants (TCA (25.3% and new antidepressants - venlafaxine, tianeptine, mirtazapine, bupropion, trazodone (15.1%. Most of the drugs were prescribed in doses which are at the lower end of the recommended dose-range. Regarding severity of the actual depressive episode, TCA were prescribed for severe depression with psychotic features, while SSRI were choice for

  15. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  16. Intravascular ultrasound based dose assessment in endovascular brachytherapy

    International Nuclear Information System (INIS)

    Catalano, Gianpiero; Tamburini, Vittorio; Colombo, Antonio; Nishida, Takahiro; Parisi, Giovanni; Mazzetta, Chiara; Orecchia, Roberto

    2003-01-01

    Background: the role of endovascular brachytherapy in restenosis prevention is well documented. Dose is usually prescribed at a fixed distance from the source axis by angiographic quantification of vessel diameter. Recently, intravascular ultrasound (IVUS) was introduced in dose prescription, allowing a better evaluation of the vessel anatomy. This study retrospectively explores the difference between prescription following angiographic vessel sizing and delivered dose calculated with IVUS. Methods and results: Seventeen lesions were studied with IVUS, identifying on irradiated segment, three sections on which measuring minimal and maximal distance from the centre of IVUS catheter to the adventitia; using dedicated software, corresponding doses were calculated. The dose ranged widely, with maximal and minimal values of 71.6 and 4.9 Gy; furthermore, heterogeneity in dose among different sections was observed. In the central section, the maximal dose was 206% of the one prescribed with the QCA model at 2 mm from the source axis, while the minimal dose was 96%. In proximal and distal sections, respective values were 182, 45, 243, and 122%. Conclusions: Our analysis confirmed the dose inhomogeneity delivered with an angiographic fixed-dose prescription strategy. A dose variation was found along the irradiated segment due to the differences in vessel thickness. IVUS emerged as an important tool in endovascular brachytherapy, especially for irregular-shaped vessels

  17. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  18. Inappropriate prescribing: criteria, detection and prevention.

    LENUS (Irish Health Repository)

    O'Connor, Marie N

    2012-06-01

    Inappropriate prescribing is highly prevalent in older people and is a major healthcare concern because of its association with negative healthcare outcomes including adverse drug events, related morbidity and hospitalization. With changing population demographics resulting in increasing proportions of older people worldwide, improving the quality and safety of prescribing in older people poses a global challenge. To date a number of different strategies have been used to identify potentially inappropriate prescribing in older people. Over the last two decades, a number of criteria have been published to assist prescribers in detecting inappropriate prescribing, the majority of which have been explicit sets of criteria, though some are implicit. The majority of these prescribing indicators pertain to overprescribing and misprescribing, with only a minority focussing on the underprescribing of indicated medicines. Additional interventions to optimize prescribing in older people include comprehensive geriatric assessment, clinical pharmacist review, and education of prescribers as well as computerized prescribing with clinical decision support systems. In this review, we describe the inappropriate prescribing detection tools or criteria most frequently cited in the literature and examine their role in preventing inappropriate prescribing and other related healthcare outcomes. We also discuss other measures commonly used in the detection and prevention of inappropriate prescribing in older people and the evidence supporting their use and their application in everyday clinical practice.

  19. Modelling Carbon Emissions in Calluna vulgaris–Dominated Ecosystems when Prescribed Burning and Wildfires Interact

    Science.gov (United States)

    Santana, Victor M.; Alday, Josu G.; Lee, HyoHyeMi; Allen, Katherine A.; Marrs, Rob H.

    2016-01-01

    A present challenge in fire ecology is to optimize management techniques so that ecological services are maximized and C emissions minimized. Here, we modeled the effects of different prescribed-burning rotation intervals and wildfires on carbon emissions (present and future) in British moorlands. Biomass-accumulation curves from four Calluna-dominated ecosystems along a north-south gradient in Great Britain were calculated and used within a matrix-model based on Markov Chains to calculate above-ground biomass-loads and annual C emissions under different prescribed-burning rotation intervals. Additionally, we assessed the interaction of these parameters with a decreasing wildfire return intervals. We observed that litter accumulation patterns varied between sites. Northern sites (colder and wetter) accumulated lower amounts of litter with time than southern sites (hotter and drier). The accumulation patterns of the living vegetation dominated by Calluna were determined by site-specific conditions. The optimal prescribed-burning rotation interval for minimizing annual carbon emissions also differed between sites: the optimal rotation interval for northern sites was between 30 and 50 years, whereas for southern sites a hump-backed relationship was found with the optimal interval either between 8 to 10 years or between 30 to 50 years. Increasing wildfire frequency interacted with prescribed-burning rotation intervals by both increasing C emissions and modifying the optimum prescribed-burning interval for minimum C emission. This highlights the importance of studying site-specific biomass accumulation patterns with respect to environmental conditions for identifying suitable fire-rotation intervals to minimize C emissions. PMID:27880840

  20. Modelling Carbon Emissions in Calluna vulgaris-Dominated Ecosystems when Prescribed Burning and Wildfires Interact.

    Science.gov (United States)

    Santana, Victor M; Alday, Josu G; Lee, HyoHyeMi; Allen, Katherine A; Marrs, Rob H

    2016-01-01

    A present challenge in fire ecology is to optimize management techniques so that ecological services are maximized and C emissions minimized. Here, we modeled the effects of different prescribed-burning rotation intervals and wildfires on carbon emissions (present and future) in British moorlands. Biomass-accumulation curves from four Calluna-dominated ecosystems along a north-south gradient in Great Britain were calculated and used within a matrix-model based on Markov Chains to calculate above-ground biomass-loads and annual C emissions under different prescribed-burning rotation intervals. Additionally, we assessed the interaction of these parameters with a decreasing wildfire return intervals. We observed that litter accumulation patterns varied between sites. Northern sites (colder and wetter) accumulated lower amounts of litter with time than southern sites (hotter and drier). The accumulation patterns of the living vegetation dominated by Calluna were determined by site-specific conditions. The optimal prescribed-burning rotation interval for minimizing annual carbon emissions also differed between sites: the optimal rotation interval for northern sites was between 30 and 50 years, whereas for southern sites a hump-backed relationship was found with the optimal interval either between 8 to 10 years or between 30 to 50 years. Increasing wildfire frequency interacted with prescribed-burning rotation intervals by both increasing C emissions and modifying the optimum prescribed-burning interval for minimum C emission. This highlights the importance of studying site-specific biomass accumulation patterns with respect to environmental conditions for identifying suitable fire-rotation intervals to minimize C emissions.

  1. Re-distribution of brachytherapy dose using a differential dose prescription adapted to risk of local failure in low-risk prostate cancer patients

    DEFF Research Database (Denmark)

    Rylander, Susanne; Polders, Daniel; Steggerda, Marcel J

    2015-01-01

    BACKGROUND AND PURPOSE: We investigated the application of a differential target- and dose prescription concept for low-dose-rate prostate brachytherapy (LDR-BT), involving a re-distribution of dose according to risk of local failure and treatment-related morbidity. MATERIAL AND METHODS: Our study......- and dose prescription concept of prescribing a lower dose to the whole gland and an escalated dose to the GTV using LDR-BT seed planning was technically feasible and resulted in a significant dose-reduction to urethra and bladder neck....

  2. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  3. STUDY OF PRESCRIBING PATTERN OF ANTIMICROBIAL AGENTS IN SELECTED PATIENTS ATTENDING TERTIARY CARE HOSPITAL IN INDIA

    Directory of Open Access Journals (Sweden)

    Anjan Adhikari

    2013-06-01

    Full Text Available Antibiotics are the most commonly prescribed drugs in hospitals and their irrational use is one of the important factors for the development and spread of resistance. The objective of this study was to evaluate the antibiotic prescription pattern in the patient attending the tertiary care hospital. It was found that a total of 333 antibiotics where prescribed in 245 prescriptions. The average number of antibiotics per prescription was approximately1.4. The most commonly used antibiotics were moxifloxacin 19.5%, metronidazole 10.4%, amoxicillin + cloxacillin 10.2% and ciprofloxacin 6%. antibiotics were almost equally prescribed to both male and female. 45.5% of the antibiotics shows adherence with the National List of Essential Medicines of India. 76.6% of the antibiotics were single products while 23.4% were fixed dose combination. The most commonly used dosage forms were tablets (57%, drops (23.5% and creams (11.7%.57.3% were prescribed irrationally. Quinolones (48.2% and antifungals (21.5% were the most common types of prescribed antibiotics in which irrationality was found.

  4. Drug prescribing and use among elderly people in Spain.

    Science.gov (United States)

    Mas, X; Laporte, J R; Frati, M E; Busquet, L; Arnau, J M; Ibañez, L; Séculi, E; Capellà, D; Arbonés, G

    1983-05-01

    As a result of the lack of an adequate regulation, the supply and the use of medicines is irrational in Spain. In order to know the characteristics of the prescription and use of drugs among the elderly, two drug utilization studies were carried out. The first study was an analysis of 981 prescriptions from an outpatient clinic of the Spanish Social Security. The results show that a high proportion of fixed-dose combinations were prescribed and that drugs without any demonstrated therapeutic value are often prescribed for the elderly. The second study was a survey of 389 individuals randomly chosen among people affiliated with a pensioners' club. The results show that drug use is highly prevalent among the elderly, that many medicines without any demonstrated benefit are being taken, and that potentially harmful drugs were being used by a high proportion of patients without medical follow-up. The prevalence of the use of some particular groups of drugs is also presented.

  5. American brachytherapy society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

    International Nuclear Information System (INIS)

    Rivard, M.J.; Butler, W.M.; Merrick, G.S.; Devlin, P.M.; Hayes, J.K.; Hearn, R.A.; Lief, E.P.; Meigooni, A.S.; Williamson, J.F.

    2008-01-01

    Purpose - In 2004, the American Association of Physicists in Medicine (AAPM) issued a report outlining recommended 125 I and 103 Pd datasets for consistency in calculating brachytherapy dose distributions. In 2005, to aid evaluating the clinical impact of implementing these datasets, the AAPM assessed the historical dependence of how prescribed doses differed from administered doses for 125 I and 103 Pd for permanent implantation of the prostate. Consequently, the American Brachytherapy Society (ABS) considered the nature of these changes towards issuing recommended dose prescriptions for 125 I and 103 Pd interstitial brachytherapy implants for mono-therapy and standard boosts. Methods and materials - An investigation was performed of the 2005 AAPM analysis to determine changes in administered dose while affixing prescribed dose using 2004 AAPM 125 I and 103 Pd brachytherapy dosimetry datasets for prostate implants. For 125 I and 103 Pd, administered dose would change by +1.4% and +4.2%, respectively. The biological and societal impact of changing prescribed dose was considered. Results - Based on the need for clinical constancy and in recognition of overall uncertainties, the ABS recommends immediate implementation of the 2004 AAPM consensus brachytherapy dosimetry datasets and no changes to 125 I and 103 Pd dose prescriptions at this time. Conclusions - Radiation oncologists should continue to prescribe mono-therapy doses of 145 Gy and 125 Gy for 125 I and 105 Pd, respectively, and standard boost doses of 100-110 Gy and 90-100 Gy for 125 I and 103 Pd, respectively. (authors)

  6. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. Antiepileptic drug prescribing before, during and after pregnancy: a study in seven European regions.

    Science.gov (United States)

    Charlton, Rachel; Garne, Ester; Wang, Hao; Klungsøyr, Kari; Jordan, Sue; Neville, Amanda; Pierini, Anna; Hansen, Anne; Engeland, Anders; Gini, Rosa; Thayer, Daniel; Bos, Jens; Puccini, Aurora; Nybo Andersen, Anne-Marie; Dolk, Helen; de Jong-van den Berg, Lolkje

    2015-11-01

    The aim of this study was to explore antiepileptic drug (AED) prescribing before, during and after pregnancy as recorded in seven population-based electronic healthcare databases. Databases in Denmark, Norway, the Netherlands, Italy (Emilia Romagna/Tuscany), Wales and the Clinical Practice Research Datalink, representing the rest of the UK, were accessed for the study. Women with a pregnancy starting and ending between 2004 and 2010, which ended in a delivery, were identified. AED prescriptions issued (UK) or dispensed (non-UK) at any time during pregnancy and the 6 months before and after pregnancy were identified in each of the databases. AED prescribing patterns were analysed, and the choice of AEDs and co-prescribing of folic acid were evaluated. In total, 978 957 women with 1 248 713 deliveries were identified. In all regions, AED prescribing declined during pregnancy and was lowest during the third trimester, before returning to pre-pregnancy levels by 6 months following delivery. For all deliveries, the prevalence of AED prescribing during pregnancy was 51 per 10 000 pregnancies (CI95 49-52%) and was lowest in the Netherlands (43/10 000; CI95 33-54%) and highest in Wales (60/10 000; CI95 54-66%). In Denmark, Norway and the two UK databases lamotrigine was the most commonly prescribed AED; whereas in the Italian and Dutch databases, carbamazepine, valproate and phenobarbital were most frequently prescribed. Few women prescribed with AEDs in the 3 months before pregnancy were co-prescribed with high-dose folic acid: ranging from 1.0% (CI95 0.3-1.8%) in Emilia Romagna to 33.5% (CI95 28.7-38.4%) in Wales. The country's differences in prescribing patterns may suggest different use, knowledge or interpretation of the scientific evidence base. The low co-prescribing of folic acid indicates that more needs to be done to better inform clinicians and women of childbearing age taking AEDs about the need to offer and receive complete preconception care

  8. The use of prescribed and non-prescribed medication by Dutch children.

    NARCIS (Netherlands)

    Dijk, L. van; Lindert, H. van

    2002-01-01

    Background: Most research on the use of medication focuses on adults. Children, however, use medication too, most of which is prescribed by GP's. Children also use non-prescribed medication (f.e. bought in the drugstore), but the extent to which is not known. Moreover, it is not known to what extent

  9. Evaluation of the appropriate use of commonly prescribed fluoroquinolones and the risk of dysglycemia

    Directory of Open Access Journals (Sweden)

    Kabbara WK

    2015-04-01

    Full Text Available Wissam K Kabbara,1 Wijdan H Ramadan,1 Peggy Rahbany,2 Souhaila Al-Natour3 1Department of Pharmacy Practice, School of Pharmacy, Lebanese American University, Byblos, Lebanon; 2Children’s National Medical Center, Washington, DC, USA; 3Medex Pharmaceutical Company, Beirut, Lebanon Background: Fluoroquinolones are among the most widely prescribed antibiotics. However, concerns about increasing resistant microorganisms and the risk of dysglycemia associated with the use of these agents have emerged.Objective: The primary objective of the study was to evaluate the appropriate use of commonly prescribed fluoroquinolones, including appropriate indication, dose, dose adjustment in renal impairment, and duration of treatment. The secondary objective was to investigate the dysglycemic effect of fluoroquinolone use (hypoglycemia and/or hyperglycemia in diabetic and nondiabetic patients.Methods: A prospective observational study at a teaching hospital in Lebanon was conducted over a 6-month period. A total of 118 patients receiving broad-spectrum fluoroquinolones (levofloxacin, ciprofloxacin, and moxifloxacin were identified. Patients were mainly recruited from internal medicine floors and intensive care units.Results: The final percentage for the appropriate indication, dose, and duration of fluoroquinolone therapy was 93.2%, 74.6%, and 57.6%, respectively. A total of 57.1% of the patients did not receive the appropriate dose adjustment according to their level of renal impairment. In addition, dysglycemia occurred in both diabetic and nondiabetic patients. Dysglycemia was more frequently encountered with ciprofloxacin (50.0%, followed by levofloxacin (42.4% and moxifloxacin (7.6%. Hyperglycemia was more common than hypoglycemia in all groups. The highest incidence of hyperglycemia occurred with levofloxacin (70.0%, followed by ciprofloxacin (39.0% and moxifloxacin (33.3%. In contrast, hypoglycemia did not occur in the ciprofloxacin group, but it was

  10. Zolpidem prescribing practices before and after Food and Drug Administration required product labeling changes

    OpenAIRE

    Norman, Jessica L; Fixen, Danielle R; Saseen, Joseph J; Saba, Laura M; Linnebur, Sunny A

    2017-01-01

    Background: Women have higher morning serum zolpidem concentrations than men after taking an evening dose, potentially leading to increased risk of harm. On 19 April 2013, the United States Food and Drug Administration required labeling changes for zolpidem, recommending an initial dose of no greater than 5 mg (immediate release) or 6.25 mg (controlled release) per night in women. Objectives: The primary objective of this study was to compare prescribing practices before and after the 2013 zo...

  11. The Supply of Prescription Opioids: Contributions of Episodic-Care Prescribers and High-Quantity Prescribers.

    Science.gov (United States)

    Schneberk, Todd; Raffetto, Brian; Kim, David; Schriger, David L

    2018-06-01

    We determine episodic and high-quantity prescribers' contribution to opioid prescriptions and total morphine milligram equivalents in California, especially among individuals prescribed large amounts of opioids. This was a cross-sectional descriptive analysis of opioid prescribing patterns during an 8-year period using the de-identified Controlled Substance Utilization Review and Evaluation System (CURES) database, the California subsection of the prescription drug monitoring program. We took a 10% random sample of all patients and stratified them by the amount of prescription opioids obtained during their maximal 90-day period. We identified "episodic prescribers" as those whose prescribing pattern included short-acting opioids on greater than 95% of all prescriptions, fewer than or equal to 31 pills on 95% of all prescriptions, only 1 prescription in the database for greater than 90% of all patients to whom they gave opioids, fewer than 6 prescriptions in the database to greater than 99% of patients given opioids, and fewer than 540 prescriptions per year. We identified top 5% prescribers by their morphine milligram equivalents per day in the database. We examined the relationship between patient opioid prescriptions and provider type, with the primary analysis performed on the patient cohort who received only short-acting opioids in an attempt to avoid guideline-concordant palliative, oncologic, and addiction care, and a secondary analysis performed on all patients. Among patients with short-acting opioid only, episodic prescribers (14.6% of 173,000 prescribers) wrote at least one prescription to 25% of 2.7 million individuals but were responsible for less than 9% of the 10.5 million opioid prescriptions and less than 3% of the 3.9 billion morphine milligram equivalents in our sample. Among individuals with high morphine milligram equivalents use, episodic prescribers were responsible for 2.8% of prescriptions and 0.6% of total morphine milligram equivalents

  12. What do providers want to know about opioid prescribing? A qualitative analysis of their questions.

    Science.gov (United States)

    Cushman, Phoebe A; Liebschutz, Jane M; Hodgkin, Joseph G; Shanahan, Christopher W; White, Julie L; Hardesty, Ilana; Alford, Daniel P

    2017-01-01

    In 2012, the US Food and Drug Administration (FDA) responded to the opioid crisis with a Risk Evaluation and Mitigation Strategy, requiring manufacturers of extended-release/long-acting opioids to fund continuing medical education based on the "FDA Blueprint for Prescriber Education." Topics in the Blueprint are "Assessing Patients for Treatment," "Initiating Therapy, Modifying Dosing, and Discontinuing Use," "Managing Therapy," "Counseling Patients and Caregivers about Safe Use," "General Drug Information," and "Specific Drug Information." Based on the FDA Blueprint, Boston University School of Medicine's "Safe and Competent Opioid Prescribing Education" (SCOPE of Pain) offers live trainings for physicians and other prescribers. During trainings, participants submit written questions about the curriculum and/or their clinical experiences. The objective was to compare themes that arose from questions asked by SCOPE of Pain participants with content of the FDA Blueprint in order to evaluate how well the Blueprint answers prescribers' concerns. The authors conducted qualitative analyses of all 1309 questions submitted by participants in 29 trainings across 16 states from May 2013 to May 2015, using conventional content analysis to code the questions. Themes that emerged from participants' questions were then compared with the Blueprint. Most themes fell into the topic categories of the Blueprint. Five main themes diverged: Participants sought information on (1) safe alternatives to opioids, (2) overcoming barriers to safe opioid prescribing, (3) government regulations of opioid prescribing, (4) the role of marijuana in opioid prescribing, and (5) maintaining a positive provider-patient relationship while prescribing opioids. In addition to learning the mechanics of safe opioid prescribing, providers want to understand government regulations and effective patient communication skills. Aware of the limitations of opioids in managing chronic pain, providers seek advice

  13. Non-intercepted dose errors in prescribing anti-neoplastic treatment

    DEFF Research Database (Denmark)

    Mattsson, T O; Holm, B; Michelsen, H

    2015-01-01

    BACKGROUND: The incidence of non-intercepted prescription errors and the risk factors involved, including the impact of computerised order entry (CPOE) systems on such errors, are unknown. Our objective was to determine the incidence, type, severity, and related risk factors of non-intercepted pr....... Strategies to prevent future prescription errors could usefully focus on integrated computerised systems that can aid dose calculations and reduce transcription errors between databases....

  14. Auditing GPs' prescribing habits : Cardiovascular prescribing frequently continues medication initiated by specialists

    NARCIS (Netherlands)

    de Vries, C.S; van Diepen, N.M; de Jong-van den Berg, L T W

    Objective: To determine to what extent general practitioners' (GPs) prescribing behaviour is a result of repeat prescribing of medication which has been initiated by specialists. Method: During a 4-week period, pharmacists identified GPs' prescriptions for a large group of cardiovascular drugs.

  15. Prescribing patterns of hydrocortisone in septic shock: a single-center experience of how surviving sepsis guidelines are interpreted and translated into bedside practice.

    Science.gov (United States)

    Contrael, Katlynd M; Killian, Alley J; Gregg, Sara R; Buchman, Timothy G; Coopersmith, Craig M

    2013-10-01

    The Surviving Sepsis Campaign suggests giving hydrocortisone to septic patients only if their "blood pressure is poorly responsive to fluid resuscitation and vasopressor therapy." Because the definition of "poorly responsive" is not provided, the purpose of this study was to identify prescribing triggers for hydrocortisone in septic shock. Retrospective chart review of patients with septic shock over 17 months, who received hydrocortisone, followed by a survey of all intensivists who attended in the study ICUs to determine whether provider attitudes matched clinical practice. Eight ICUs in an academic hospital and a hybrid academic/community hospital. A total of 155 patients with septic shock in whom vasopressors were initiated and hydrocortisone was prescribed. Ninety-nine patients (64%) were already receiving two vasopressors before hydrocortisone was prescribed. An additional 22 patients were on a single high-dose vasopressor prior to corticosteroid initiation. Of patients who survived to have their hydrocortisone dose changed, 57% had their corticosteroids tapered, whereas 43% were abruptly discontinued. Seventy-six percent of patients were no longer on vasopressors when the first dosing change was made. Twenty-seven out of 36 intensivists (75%) completed the survey. The majority (72%) defined "poorly responsive to vasopressors" as the presence of two vasopressors, and 70% stated that they required patients to be off vasopressors prior to altering the corticosteroid dose. Significant variability exists when corticosteroids are prescribed for septic shock, with the most common interpretation in our institution of "poorly responsive to fluid resuscitation and vasopressor therapy" being the presence of two vasopressors. The method and timing of corticosteroid discontinuation also differed among providers. Self-described prescribing patterns from intensivists closely matched their actual behavior, suggesting variability is due to differing interpretations of the

  16. Optimization of equivalent uniform dose using the L-curve criterion

    International Nuclear Information System (INIS)

    Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R

    2007-01-01

    Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning

  17. Optimization of equivalent uniform dose using the L-curve criterion

    Energy Technology Data Exchange (ETDEWEB)

    Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R [Department of Radiation Oncology, University of Florida, Gainesville, FL 32610-0385 (United States)

    2007-09-21

    Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.

  18. Optimization of equivalent uniform dose using the L-curve criterion.

    Science.gov (United States)

    Chvetsov, Alexei V; Dempsey, James F; Palta, Jatinder R

    2007-10-07

    Optimization of equivalent uniform dose (EUD) in inverse planning for intensity-modulated radiation therapy (IMRT) prevents variation in radiobiological effect between different radiotherapy treatment plans, which is due to variation in the pattern of dose nonuniformity. For instance, the survival fraction of clonogens would be consistent with the prescription when the optimized EUD is equal to the prescribed EUD. One of the problems in the practical implementation of this approach is that the spatial dose distribution in EUD-based inverse planning would be underdetermined because an unlimited number of nonuniform dose distributions can be computed for a prescribed value of EUD. Together with ill-posedness of the underlying integral equation, this may significantly increase the dose nonuniformity. To optimize EUD and keep dose nonuniformity within reasonable limits, we implemented into an EUD-based objective function an additional criterion which ensures the smoothness of beam intensity functions. This approach is similar to the variational regularization technique which was previously studied for the dose-based least-squares optimization. We show that the variational regularization together with the L-curve criterion for the regularization parameter can significantly reduce dose nonuniformity in EUD-based inverse planning.

  19. The minimum knowledge base for predicting organ-at-risk dose-volume levels and plan-related complications in IMRT planning

    International Nuclear Information System (INIS)

    Zhang, Hao H; D'Souza, Warren D; Meyer, Robert R; Shi Leyuan

    2010-01-01

    IMRT treatment planning requires consideration of two competing objectives: achieving the required amount of radiation for the planning target volume and minimizing the amount of radiation delivered to all other tissues. It is important for planners to understand the tradeoff between competing factors so that the time-consuming human interaction loop (plan-evaluate-modify) can be eliminated. Treatment-plan-surface models have been proposed as a decision support tool to aid treatment planners and clinicians in choosing between rival treatment plans in a multi-plan environment. In this paper, an empirical approach is introduced to determine the minimum number of treatment plans (minimum knowledge base) required to build accurate representations of the IMRT plan surface in order to predict organ-at-risk (OAR) dose-volume (DV) levels and complications as a function of input DV constraint settings corresponding to all involved OARs in the plan. We have tested our approach on five head and neck patients and five whole pelvis/prostate patients. Our results suggest that approximately 30 plans were sufficient to predict DV levels with less than 3% relative error in both head and neck and whole pelvis/prostate cases. In addition, approximately 30-60 plans were sufficient to predict saliva flow rate with less than 2% relative error and to classify rectal bleeding with an accuracy of 90%.

  20. The use of Fricke dosimeter to determine the absorbed dose from brachytherapy equipment in the Northeastern Brazil

    International Nuclear Information System (INIS)

    Souza, Vivianne Lucia B.; Cunha, Manuela S.; Figueiredo, Marcela D.C.; Santos, Carla D.A.; Rodrigues, Kelia R.G.; Lira, Gabriela B.S.; Silva, Danubia B.; Melo, Roberto T.

    2011-01-01

    This paper describes the practical results of an assessment of the situation of brachytherapy services throughout the Northeast. A Fricke dosimetry system capable of verifying the dose absorbed in water, prepared by researchers from the Regional Center of Nuclear Sciences was brought to public hospitals in the Northeast. The system not only evaluates if the applied (measured) dose is close to the calculated (prescribed) dose, but is also capable of verifying human errors and/or mechanical or the International Atomic Energy Agency (IAEA) standards regarding the percentage of allowed difference between the prescribed dose and dose measurement. (author)

  1. Impact of Prior Therapeutic Opioid Use by Emergency Department Providers on Opioid Prescribing Decisions

    Directory of Open Access Journals (Sweden)

    Adam C Pomerleau

    2016-11-01

    Full Text Available INTRODUCTION: Our study sought to examine the opioid analgesic (OA prescribing decisions of emergency department (ED providers who have themselves used OA therapeutically and those who have not. A second objective was to determine if OA prescribing decisions would differ based on the patient's relationship to the provider. METHODS: We distributed an electronic survey to a random sample of ED providers at participating centers in a nationwide research consortium. Question topics included provider attitudes about OA prescribing, prior personal therapeutic use of OAs (indications, dosing, and disposal of leftover medication, and hypothetical analgesic-prescribing decisions for their patients, family members, and themselves for different painful conditions. RESULTS: The total survey population was 957 individuals; 515 responded to the survey, a 54% response rate. Prior personal therapeutic OA use was reported in 63% (95% CI = [58-68]. A majority of these providers (82%; 95% CI = [77-87] took fewer than half the number of pills prescribed. Regarding provider attitudes towards OA prescribing, 66% (95% CI = [61-71] agreed that OA could lead to addiction even with short-term use. When providers were asked if they would prescribe OA to a patient with 10/10 pain from an ankle sprain, 21% (95% CI = [17-25] would for an adult patient, 13% (95% CI = [10-16] would for an adult family member, and 6% (95% CI = [4-8] indicated they themselves would take an opioid for the same pain. When the scenario involved an ankle fracture, 86% (95% CI = [83-89] would prescribe OA for an adult patient, 75% (95% CI = [71-79] for an adult family member, and 52% (95% CI = [47-57] would themselves take OA. Providers who have personally used OA to treat their pain were found to make similar prescribing decisions compared to those who had not. CONCLUSION: No consistent differences in prescribing decisions were found between ED providers based on their prior therapeutic use of OA

  2. Reduction of the scatter dose to the testicle outside the radiation treatment fields

    International Nuclear Information System (INIS)

    Kubo, H.; Shipley, W.U.

    1982-01-01

    A technique is described to reduce the dose to the contralateral testicle of patients with testis tumors during retroperitoneal therapy with 10 MV X-rays. When a conventional clam-shell shielding device was used, the dose to the testis from the photons scattered by the patient and the collimator jaws was found to be about 1.6% of the prescribed midplane dose. A more substantial gonadal shield made of low melting Ostalloy, that reduced further the dose from internal scattered X rays, was therefore designed. A 10 cm thick lead scrotal block above the scrotum immediately outside the field is shown to reduce the external scattered radiation to negligible levels. Using the shield and the block, it is possible to reduce the dose to the testicle to one-tenth of one percent of the prescribed midplane dose

  3. Reduction of the scatter dose to the testicle outside the radiation treatment fields

    International Nuclear Information System (INIS)

    Kubo, H.; Shipley, W.U.

    1982-01-01

    A technique is described to reduce the dose to the contralateral testicle of patients with testis tumors during retroperitoneal therapy with 10 MV X rays. When a conventional clam-shell shielding device was used, the dose to the testis from the photons scattered by the patient and collimator jaws was found to be about 1.6% of the prescribed midplane dose. A more substantial gonadal shield made of low melting point Ostalloy, that reduced further the dose from internal scattered X rays, was therefore designed. A 10 cm thick lead scrotal block above the scrotum immediately outside the field is shown to reduce the external scattering radiation to negligible levels. Using the shield and the block, it is possible to reduce the dose to the testicle to one-tenth of one percent of the prescribed midplane dose

  4. Radiation dose ≥54 Gy and CA 19–9 response are associated with improved survival for unresectable, non-metastatic pancreatic cancer treated with chemoradiation

    Directory of Open Access Journals (Sweden)

    Golden Daniel W

    2012-09-01

    Full Text Available Abstract Background Unresectable pancreatic cancer (UPC has low survival. With improving staging techniques and systemic therapy, local control in patients without metastatic disease may have increasing importance. We investigated whether the radiation dose used in chemoradiation (CRT as definitive treatment for UPC and the CA 19–9 response to therapy have an impact on overall survival (OS. Methods From 1997–2009 46 patients were treated with CRT for non-metastatic UPC. Median prescribed RT dose was 54 Gy (range 50.4-59.4 Gy. All patients received concurrent chemotherapy (41: 5-fluorouracil, 5: other and 24 received adjuvant chemotherapy. Results 41 patients were inoperable due to T4 disease and 5 patients with T3 disease were medically inoperable. Five patients did not complete CRT due to progressive disease or treatment-related toxicity (median RT dose 43.2 Gy. Overall, 42 patients were dead of disease at the time of last follow-up. The median and 12 month OS were 8.8 months and 35%, respectively. By univariate analysis, minimum CA 19–9 post-CRT Conclusions CRT as definitive treatment for UPC had low survival. However, our retrospective data suggest that patients treated to ≥54 Gy or observed to have a minimum post-CRT CA 19–9

  5. Protocol: mixed-methods study to evaluate implementation, enforcement, and outcomes of U.S. state laws intended to curb high-risk opioid prescribing.

    Science.gov (United States)

    McGinty, Emma E; Stuart, Elizabeth A; Caleb Alexander, G; Barry, Colleen L; Bicket, Mark C; Rutkow, Lainie

    2018-02-26

    The U.S. opioid epidemic has been driven by the high volume of opioids prescribed by healthcare providers. U.S. states have recently enacted four types of laws designed to curb high-risk prescribing practices, such as high-dose and long-term opioid prescribing, associated with opioid-related mortality: (1) mandatory Prescription Drug Monitoring Program (PDMP) enrollment laws, which require prescribers to enroll in their state's PDMP, an electronic database of patients' controlled substance prescriptions, (2) mandatory PDMP query laws, which require prescribers to query the PDMP prior to prescribing an opioid, (3) opioid prescribing cap laws, which limit the dose and/or duration of opioid prescriptions, and (4) pill mill laws, which strictly regulate pain clinics to prevent nonmedical opioid prescribing. Some pain experts have expressed concern that these laws could negatively affect pain management among patients with chronic non-cancer pain. This paper describes the protocol for a mixed-methods study analyzing the independent effects of these four types of laws on opioid prescribing patterns and chronic non-cancer pain treatment, accounting for variation in implementation and enforcement of laws across states. Many states have enacted multiple opioid prescribing laws at or around the same time. To overcome this issue, our study focuses on 18 treatment states that each enacted a single law of interest, and no other potentially confounding laws, over a 4-year period (2 years pre-/post-law). Qualitative interviews with key leaders in each of the 18 treatment states will characterize the timing, scope, and strength of each state law's implementation and enforcement. This information will inform the design and interpretation of synthetic control models analyzing the effects of each of the two types of laws on two sets of outcomes: measures of (1) high-risk opioid prescribing and (2) non-opioid treatments for chronic non-cancer pain. Study of mandatory PDMP enrollment

  6. Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds

    International Nuclear Information System (INIS)

    Guix, Benjamin; Finestres, Fernando; Tello, Jose-Ignacio; Palma, Cesar; Martinez, Antonio; Guix, Jose-Ramon; Guix, Ricardo

    2000-01-01

    Purpose: To analyze the results obtained in a prospective group of patients with basal or squamous cell skin carcinomas of the face treated by high-dose-rate (HDR) brachytherapy via custom-made surface molds. Methods and Materials: A total of 136 patients with basal or squamous cell carcinomas of the face were treated between March 1992 and March 1997 by surface molds and HDR brachytherapy with iridium-192. Nineteen patients were treated with standard Brock applicators and 117 patients with custom-made polymethyl methacrylate applicators, built over a plaster mold obtained of the patient's face. Minimum dose administered to the tumor was 6000 to 6500 cGy in 33 to 36 fractions at 180 cGy/fraction in lesions of up to 4 cm. Lesions greater than 4 cm were boosted up to 7500-8000 cGy after a 3-week pause. Results: With the custom-made surface molds, the dose distribution was uniform in the surface of the skin and at 5 mm depth in the whole area of the applicator. Differences between the areas of maximum and minimum dose at this depth never reached values higher than 5% of the prescribed dose. At the edges of the custom-made molds dose gradient was sharp, with the detected dose at 5 mm from the applicator being negligible. All the patients were complete responders. There were 3 local recurrences, 1/73 patients treated for primary tumor and 2/63 patients treated for recurrent tumor. Actuarial local control at 5 years for all patients was 98%, for those patients with primary tumors 99%, and for recurrent patients 87%. The treatment tolerance was excellent in all cases. No severe, early, or late, complications were detected. Conclusions: Radiotherapy is a highly effective treatment of skin carcinomas of the face. Custom-made molds, to be used in conjunction with HDR brachytherapy equipment, make possible a uniform dose distribution, with a sharp dose gradient in the limits of applicators. Custom-made surface molds are easy and safe to use, and they fit very accurately for

  7. Combined feedforward and model-assisted active disturbance rejection control for non-minimum phase system.

    Science.gov (United States)

    Sun, Li; Li, Donghai; Gao, Zhiqiang; Yang, Zhao; Zhao, Shen

    2016-09-01

    Control of the non-minimum phase (NMP) system is challenging, especially in the presence of modelling uncertainties and external disturbances. To this end, this paper presents a combined feedforward and model-assisted Active Disturbance Rejection Control (MADRC) strategy. Based on the nominal model, the feedforward controller is used to produce a tracking performance that has minimum settling time subject to a prescribed undershoot constraint. On the other hand, the unknown disturbances and uncertain dynamics beyond the nominal model are compensated by MADRC. Since the conventional Extended State Observer (ESO) is not suitable for the NMP system, a model-assisted ESO (MESO) is proposed based on the nominal observable canonical form. The convergence of MESO is proved in time domain. The stability, steady-state characteristics and robustness of the closed-loop system are analyzed in frequency domain. The proposed strategy has only one tuning parameter, i.e., the bandwidth of MESO, which can be readily determined with a prescribed robustness level. Some comparative examples are given to show the efficacy of the proposed method. This paper depicts a promising prospect of the model-assisted ADRC in dealing with complex systems. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Prescribed fire research in Pennsylvania

    Science.gov (United States)

    Patrick Brose

    2009-01-01

    Prescribed fire in Pennsylvania is a relatively new forestry practice because of the State's adverse experience with highly destructive wildfires in the early 1900s. The recent introduction of prescribed fire raises a myriad of questions regarding its correct and safe use. This poster briefly describes the prescribed fire research projects of the Forestry Sciences...

  9. Prescriber and staff perceptions of an electronic prescribing system in primary care: a qualitative assessment

    Directory of Open Access Journals (Sweden)

    Sittig Dean F

    2010-11-01

    Full Text Available Abstract Background The United States (US Health Information Technology for Economic and Clinical Health Act of 2009 has spurred adoption of electronic health records. The corresponding meaningful use criteria proposed by the Centers for Medicare and Medicaid Services mandates use of computerized provider order entry (CPOE systems. Yet, adoption in the US and other Western countries is low and descriptions of successful implementations are primarily from the inpatient setting; less frequently the ambulatory setting. We describe prescriber and staff perceptions of implementation of a CPOE system for medications (electronic- or e-prescribing system in the ambulatory setting. Methods Using a cross-sectional study design, we conducted eight focus groups at three primary care sites in an independent medical group. Each site represented a unique stage of e-prescribing implementation - pre/transition/post. We used a theoretically based, semi-structured questionnaire to elicit physician (n = 17 and staff (n = 53 perceptions of implementation of the e-prescribing system. We conducted a thematic analysis of focus group discussions using formal qualitative analytic techniques (i.e. deductive framework and grounded theory. Two coders independently coded to theoretical saturation and resolved discrepancies through discussions. Results Ten themes emerged that describe perceptions of e-prescribing implementation: 1 improved availability of clinical information resulted in prescribing efficiencies and more coordinated care; 2 improved documentation resulted in safer care; 3 efficiencies were gained by using fewer paper charts; 4 organizational support facilitated adoption; 5 transition required time; resulted in workload shift to staff; 6 hardware configurations and network stability were important in facilitating workflow; 7 e-prescribing was time-neutral or time-saving; 8 changes in patient interactions enhanced patient care but required education; 9 pharmacy

  10. Safe prescribing: a titanic challenge

    Science.gov (United States)

    Routledge, Philip A

    2012-01-01

    The challenge to achieve safe prescribing merits the adjective ‘titanic’. The organisational and human errors leading to poor prescribing (e.g. underprescribing, overprescribing, misprescribing or medication errors) have parallels in the organisational and human errors that led to the loss of the Titanic 100 years ago this year. Prescribing can be adversely affected by communication failures, critical conditions, complacency, corner cutting, callowness and a lack of courage of conviction, all of which were also factors leading to the Titanic tragedy. These issues need to be addressed by a commitment to excellence, the final component of the ‘Seven C's’. Optimal prescribing is dependent upon close communication and collaborative working between highly trained health professionals, whose role is to ensure maximum clinical effectiveness, whilst also protecting their patients from avoidable harm. Since humans are prone to error, and the environments in which they work are imperfect, it is not surprising that medication errors are common, occurring more often during the prescribing stage than during dispensing or administration. A commitment to excellence in prescribing includes a continued focus on lifelong learning (including interprofessional learning) in pharmacology and therapeutics. This should be accompanied by improvements in the clinical working environment of prescribers, and the encouragement of a strong safety culture (including reporting of adverse incidents as well as suspected adverse drug reactions whenever appropriate). Finally, members of the clinical team must be prepared to challenge each other, when necessary, to ensure that prescribing combines the highest likelihood of benefit with the lowest potential for harm. PMID:22738396

  11. Neuropharmacology and mental health nurse prescribers.

    Science.gov (United States)

    Skingsley, David; Bradley, Eleanor J; Nolan, Peter

    2006-08-01

    To outline the development and content of a 'top-up' neuropharmacology module for mental health nurse prescribers and consider how much pharmacology training is required to ensure effective mental health prescribing practice. Debate about the content of prescribing training courses has persisted within the United Kingdom since the mid-1980s. In early 2003 supplementary prescribing was introduced and gave mental health nurses the opportunity to become prescribers. The challenge of the nurse prescribing curriculum for universities is that they have only a short time to provide nurses from a range of backgrounds with enough knowledge to ensure that they meet agreed levels of competency for safe prescribing. There is growing concern within mental health care that the prescribing of medication in mental health services falls short of what would be deemed good practice. Over the past two decades, nurse training has increasingly adopted a psychosocial approach to nursing care raising concerns that, although nurses attending prescribing training may be able to communicate effectively with service users, they may lack the basic knowledge of biology and pharmacology to make effective decisions about medication. Following the completion of a general nurse prescribing course, mental health nurses who attended were asked to identify their specific needs during the evaluation phase. Although they had covered basic pharmacological principles in their training, they stated that they needed more specific information about drugs used in mental health; particularly how to select appropriate drug treatments for mental health conditions. This paper describes how the nurses were involved in the design of a specific module which would enable them to transfer their theoretical leaning to practice and in so doing increase their confidence in their new roles. The findings of this study suggest that the understanding and confidence of mental health nurse prescribers about the drugs they

  12. Effect of physiological factors on dose due to organically bound tritium

    International Nuclear Information System (INIS)

    Trivedi, A.

    1998-01-01

    The International Commission on Radiological Protection (ICRP) recommends the understanding of the effect of age, anatomical and physiological data on the doses in order to prescribe dose coefficient for radionuclides. The published data on OBT dose fraction after acute or chronic intakes of HTO are evaluated to examine the variation of OBT dose with the age and physiology of occupational workers. (author)

  13. Prescribing antibiotics in general practice:

    DEFF Research Database (Denmark)

    Sydenham, Rikke Vognbjerg; Pedersen, Line Bjørnskov; Plejdrup Hansen, Malene

    Objectives The majority of antibiotics are prescribed from general practice. The use of broad-spectrum antibiotics increases the risk of development of bacteria resistant to antibiotic treatment. In spite of guidelines aiming to minimize the use of broad-spectrum antibiotics we see an increase...... in the use of these agents. The overall aim of the project is to explore factors influencing the decision process and the prescribing behaviour of the GPs when prescribing antibiotics. We will study the impact of microbiological testing on the choice of antibiotic. Furthermore the project will explore how...... the GPs’ prescribing behaviour is influenced by selected factors. Method The study consists of a register-based study and a questionnaire study. The register-based study is based on data from the Register of Medicinal Product Statistics (prescribed antibiotics), Statistics Denmark (socio-demographic data...

  14. Drug use evaluation of antibiotics prescribed in a Jordanian hospital outpatient and emergency clinics using WHO prescribing indicators

    International Nuclear Information System (INIS)

    Al-Niemat, Sahar I.; Bloukh, Diana T.; Al-Harasis, Manal D.; Al-Fanek, Alen F.; Salah, Rehab K.

    2008-01-01

    Objective was to evaluate the use of antibiotics prescribed in hospital outpatient and emergency clinics in King Hussein Medical Centre (KHMC) using WHO prescribing indicators in an attempt to rationalize the use of antibiotics in the Royal Medical Services. We retrospectively surveyed a sample of 187,822 antibiotic prescriptions obtained from 5 outpatient pharmacies in KHMC written over the period of 3 consecutive months May 2007 to July 2007. The percentage of encounters of an antibiotic prescribed was calculated using the methodology recommended by the WHO. An additional indicator, the percentage share of different antibiotics was also included to identify the frequency prescribed from those antibiotics. The average percentage of prescriptions involving antibiotics was 35.6% out of 187,822 prescriptions surveyed. From these, 65,500 antibiotic prescriptions were observed. Penicillins most frequently amoxcillins and Quinolones most frequently ciprofloxacinllin and norfloxacillin were the most commonly prescribed antibiotics with an average percentage of 31.8% and 27.5%. The average prescribing rate for the other antibiotic categories was as follows: macrolides 5.2%, cephalosporins 16% and amoxcillins/clavulanate 5.4%. The high percentage of prescriptions involving antibiotics observed in KHMC pharmacies requires rational use of antibiotics and judicious prescribing by Military prescribers. An insight into factors influencing antibiotic prescribing patterns and adherence to antibiotic prescribing guidelines by the Military prescribers is warranted. (author)

  15. Validation of a label dosimeter with regard to dose assurance in critical applications as quarantine control

    Energy Technology Data Exchange (ETDEWEB)

    Ehlermann, D A.E. [Institute of Process Engineering, Federal Research Centre for Nutrition, Karlsruhe (Germany)

    1999-03-01

    A `label dosimeter` (dose-threshold indicator) for dose ranges of insect disinfestation became commercially available only recently. It was studied for dosimetric (metrological) properties elsewhere. The fundamental problem of its application in practice is the relation between the dose observed at a reference position and the critical minimum dose achieved in a consignment. For this reason several irradiation geometries (relations between the arrangement of the goods during irradiation and the type of the radiation source, gamma, electrons, X-rays) were studied. The observed dose distributions revealed the difficulty that for any such geometry a `label dosimeter` with a specific but differing threshold dose-value must be utilized in order to guarantee the adherence to the required minimum dose value. The `label dosimeter` must be placed at a position where the minimum dose is likely to occur. In situations where the position of the minimum dose is not accessible extrapolation from the dose observed at a reference position is less reliable. (author) 6 refs, 5 figs, 1 tab

  16. Validation of a label dosimeter with regard to dose assurance in critical applications as quarantine control

    International Nuclear Information System (INIS)

    Ehlermann, D.A.E.

    1999-01-01

    A 'label dosimeter' (dose-threshold indicator) for dose ranges of insect disinfestation became commercially available only recently. It was studied for dosimetric (metrological) properties elsewhere. The fundamental problem of its application in practice is the relation between the dose observed at a reference position and the critical minimum dose achieved in a consignment. For this reason several irradiation geometries (relations between the arrangement of the goods during irradiation and the type of the radiation source, gamma, electrons, X-rays) were studied. The observed dose distributions revealed the difficulty that for any such geometry a 'label dosimeter' with a specific but differing threshold dose-value must be utilized in order to guarantee the adherence to the required minimum dose value. The 'label dosimeter' must be placed at a position where the minimum dose is likely to occur. In situations where the position of the minimum dose is not accessible extrapolation from the dose observed at a reference position is less reliable. (author)

  17. Nurse practitioner prescribing: an international perspective

    Directory of Open Access Journals (Sweden)

    Fong J

    2015-10-01

    Full Text Available Jacqueline Fong,1,2 Thomas Buckley,2 Andrew Cashin3 1St George Hospital, Kogarah, 2Sydney Nursing School, University of Sydney, Camperdown, NSW, Australia; 3School of Health and Human Sciences, Southern Cross University, Lismore, NSW, Australia Background: Internationally, the delivery of care provided by nurses and midwives has undergone a significant change due to a variety of interrelated factors, including economic circumstances, a diminishing number of medical providers, the unavailability of adequate health care services in underserved and rural areas, and growing specialization among the professions. One solution to the challenges of care delivery has been the introduction of nurse practitioners (NPs and the authorization of NPs to prescribe medicines. Aim: The aim of this paper was to review the current international literature related to NP prescribing and compare the findings to the Australian context. The review focuses on literature from the United States, Canada, Europe, Australia, and New Zealand. Methods: Databases were searched from January 2000 to January 2015. The following keywords: “nurse practitioner”, “advanced nurse”, “advanced practice nurse”, “prescri*”, “Australia”, “United States America”, “UK”, “New Zealand”, “Canada”, “Europe”, “drug prescri*”, “prescri* authority”, and “prescri* legislation” were used. Findings: NPs tend to prescribe in differing contexts of practice to provide care in underserved populations and require good systems literacy to practice across complex systems. The key themes identified internationally related to NP prescribing relate to barriers to prescribing, confidence in prescribing, and the unique role of NPs in prescribing medicines, eg, the high prevalence of prescribing pain medicines in several countries, including Australia. Conclusion: Across all countries reviewed, there appears a need for further research into the organizational and

  18. Safe prescribing: a titanic challenge.

    Science.gov (United States)

    Routledge, Philip A

    2012-10-01

    The challenge to achieve safe prescribing merits the adjective 'titanic'. The organisational and human errors leading to poor prescribing (e.g. underprescribing, overprescribing, misprescribing or medication errors) have parallels in the organisational and human errors that led to the loss of the Titanic 100 years ago this year. Prescribing can be adversely affected by communication failures, critical conditions, complacency, corner cutting, callowness and a lack of courage of conviction, all of which were also factors leading to the Titanic tragedy. These issues need to be addressed by a commitment to excellence, the final component of the 'Seven C's'. Optimal prescribing is dependent upon close communication and collaborative working between highly trained health professionals, whose role is to ensure maximum clinical effectiveness, whilst also protecting their patients from avoidable harm. Since humans are prone to error, and the environments in which they work are imperfect, it is not surprising that medication errors are common, occurring more often during the prescribing stage than during dispensing or administration. A commitment to excellence in prescribing includes a continued focus on lifelong learning (including interprofessional learning) in pharmacology and therapeutics. This should be accompanied by improvements in the clinical working environment of prescribers, and the encouragement of a strong safety culture (including reporting of adverse incidents as well as suspected adverse drug reactions whenever appropriate). Finally, members of the clinical team must be prepared to challenge each other, when necessary, to ensure that prescribing combines the highest likelihood of benefit with the lowest potential for harm. © 2012 The Author. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  19. A Technological Innovation to Reduce Prescribing Errors Based on Implementation Intentions: The Acceptability and Feasibility of MyPrescribe.

    Science.gov (United States)

    Keyworth, Chris; Hart, Jo; Thoong, Hong; Ferguson, Jane; Tully, Mary

    2017-08-01

    Although prescribing of medication in hospitals is rarely an error-free process, prescribers receive little feedback on their mistakes and ways to change future practices. Audit and feedback interventions may be an effective approach to modifying the clinical practice of health professionals, but these may pose logistical challenges when used in hospitals. Moreover, such interventions are often labor intensive. Consequently, there is a need to develop effective and innovative interventions to overcome these challenges and to improve the delivery of feedback on prescribing. Implementation intentions, which have been shown to be effective in changing behavior, link critical situations with an appropriate response; however, these have rarely been used in the context of improving prescribing practices. Semistructured qualitative interviews were conducted to evaluate the acceptability and feasibility of providing feedback on prescribing errors via MyPrescribe, a mobile-compatible website informed by implementation intentions. Data relating to 200 prescribing errors made by 52 junior doctors were collected by 11 hospital pharmacists. These errors were populated into MyPrescribe, where prescribers were able to construct their own personalized action plans. Qualitative interviews with a subsample of 15 junior doctors were used to explore issues regarding feasibility and acceptability of MyPrescribe and their experiences of using implementation intentions to construct prescribing action plans. Framework analysis was used to identify prominent themes, with findings mapped to the behavioral components of the COM-B model (capability, opportunity, motivation, and behavior) to inform the development of future interventions. MyPrescribe was perceived to be effective in providing opportunities for critical reflection on prescribing errors and to complement existing training (such as junior doctors' e-portfolio). The participants were able to provide examples of how they would use

  20. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  1. Demonstration of brachytherapy boost dose-response relationships in glioblastoma multiforme

    International Nuclear Information System (INIS)

    Sneed, Penny K.; Lamborn, Kathleen R.; Larson, David A.; Prados, Michael D.; Malec, Mary K.; McDermott, Michael W.; Weaver, Keith A.; Phillips, Theodore L.; Wara, William M.; Gutin, Philip H.

    1996-01-01

    Purpose: To evaluate brachytherapy dose-response relationships in adults with glioblastoma undergoing temporary 125 I implant boost after external beam radiotherapy. Methods and Materials: Since June 1987, orthogonal radiographs using a fiducial marker box have been used to verify brain implant source positions and generate dose-volume histograms at the University of California, San Francisco. For adults who underwent brachytherapy boost for glioblastoma from June 1987 through December 1992, tumor volumes were reoutlined to ensure consistency and dose-volume histograms were recalculated. Univariate and multivariate analyses of various patient and treatment parameters were performed evaluating for influence of dose on freedom from local failure (FFLF) and actuarial survival. Results: Of 102 implant boosts, 5 were excluded because computer plans were unavailable. For the remaining 97 patients, analyses with adjustment for known prognostic factors (age, KPS, extent of initial surgical resection) and prognostic factors identified on univariate testing (adjuvant chemotherapy) showed that higher minimum brachytherapy tumor dose was strongly associated with improved FFLF (p = 0.001). A quadratic relationship was found between total biological effective dose and survival, with a trend toward optimal survival probability at 47 Gy minimum brachytherapy tumor dose (corresponding to about 65 Gy to 95% of the tumor volume); survival decreased with lower or higher doses. Two patients expired and one requires hospice care because of brain necrosis after brachytherapy doses > 63 Gy to 95% of the tumor volume with 60 Gy to > 18 cm 3 of normal brain. Conclusion: Although higher minimum brachytherapy tumor dose was strongly associated with better local control, a brachytherapy boost dose > 50-60 Gy may result in life-threatening necrosis. We recommend careful conformation of the prescription isodose line to the contrast enhancing tumor volume, delivery of a minimum brachytherapy

  2. Medication prescribing errors in a public teaching hospital in India: A prospective study.

    Directory of Open Access Journals (Sweden)

    Pote S

    2007-03-01

    Full Text Available Background: To prevent medication errors in prescribing, one needs to know their types and relative occurrence. Such errors are a great cause of concern as they have the potential to cause patient harm. The aim of this study was to determine the nature and types of medication prescribing errors in an Indian setting.Methods: The medication errors were analyzed in a prospective observational study conducted in 3 medical wards of a public teaching hospital in India. The medication errors were analyzed by means of Micromedex Drug-Reax database.Results: Out of 312 patients, only 304 were included in the study. Of the 304 cases, 103 (34% cases had at least one error. The total number of errors found was 157. The drug-drug interactions were the most frequently (68.2% occurring type of error, which was followed by incorrect dosing interval (12% and dosing errors (9.5%. The medication classes involved most were antimicrobial agents (29.4%, cardiovascular agents (15.4%, GI agents (8.6% and CNS agents (8.2%. The moderate errors contributed maximum (61.8% to the total errors when compared to the major (25.5% and minor (12.7% errors. The results showed that the number of errors increases with age and number of medicines prescribed.Conclusion: The results point to the establishment of medication error reporting at each hospital and to share the data with other hospitals. The role of clinical pharmacist in this situation appears to be a strong intervention; and the clinical pharmacist, initially, could confine to identification of the medication errors.

  3. Smartphone apps to support hospital prescribing and pharmacology education: a review of current provision.

    Science.gov (United States)

    Haffey, Faye; Brady, Richard R W; Maxwell, Simon

    2014-01-01

    Junior doctors write the majority of hospital prescriptions but many indicate they feel underprepared to assume this responsibility and around 10% of prescriptions contain errors. Medical smartphone apps are now widely used in clinical practice and present an opportunity to provide support to inexperienced prescribers. This study assesses the contemporary range of smartphone apps with prescribing or related content. Six smartphone app stores were searched for apps aimed at the healthcare professional with drug, pharmacology or prescribing content. Three hundred and six apps were identified. 34% appeared to be for use within the clinical environment in order to aid prescribing, 14% out with the clinical setting and 51% of apps were deemed appropriate for both clinical and non-clinical use. Apps with drug reference material, such as textbooks, manuals or medical apps with drug information were the commonest apps found (51%), followed by apps offering drug or infusion rate dose calculation (26%). 68% of apps charged for download, with a mean price of £14.25 per app and a range of £0.62-101.90. A diverse range of pharmacology-themed apps are available and there is further potential for the development of contemporary apps to improve prescribing performance. Personalized app stores may help universities/healthcare organizations offer high quality apps to students to aid in pharmacology education. Users of prescribing apps must be aware of the lack of information regarding the medical expertise of app developers. This will enable them to make informed choices about the use of such apps in their clinical practice. © 2013 The British Pharmacological Society.

  4. Effect of Endurance Training on The Lactate and Glucose Minimum Intensities

    Directory of Open Access Journals (Sweden)

    Pedro B. Junior, Vitor L. de Andrade, Eduardo Z. Campos, Carlos A. Kalva-Filho, Alessandro M. Zagatto, Gustavo G. de Araújo, Marcelo Papoti

    2018-03-01

    Full Text Available Due to the controversy about the sensitive of lactate minimum intensity (LMI to training and the need to develop other tool for aerobic fitness evaluation, the purpose of this study was to analyze the sensitivity of glucose minimum intensity (GMI and LMI to endurance training. Eight trained male cyclists (21.4 ± 1.9 years, 67.6 ± 7.5 kg and 1.72 ± 0.10 m were evaluated twice, before and after 12 weeks of training. GMI and LMI were calculated, respectively, by the lowest blood glucose and lactate values attained during an incremental test performed after a hyperlactemia induction, and VO2max was determined during standard incremental effort. The training was prescribed in three different zones and controlled by heart rate (HR. The training distribution was equivalent to 59.7%, 25.0% and 15.3% below, at and above anaerobic threshold HR respectively. The anaerobic threshold evaluated by GMI and LMI improvement 9.89 ± 4.35% and 10.28 ± 9.89 respectively, after training, but the VO2max 2.52 ± 1.81%. No differences were found between GMI and LMI in pre (218.2 ± 22.1 vs 215.0 ± 18.6 W and post (240.6 ± 22.9 vs 237.5 ± 18.8 W training situations. LMI and GMI were sensitive to 12-week aerobic training in cyclist; thus, both protocols can be used to assess aerobic adaptation, athletes diagnostic and prescribe training.

  5. Prescribing practices amid the OxyContin crisis: examining the effect of print media coverage on opioid prescribing among physicians.

    Science.gov (United States)

    Borwein, Alexandra; Kephart, George; Whelan, Emma; Asbridge, Mark

    2013-12-01

    The pain medication OxyContin (hereafter referred to as oxycodone extended release) has been the subject of sustained, and largely negative, media attention in recent years. We sought to determine whether media coverage of oxycodone extended release in North American newspapers has led to changes in prescribing of the drug in Nova Scotia, Canada. An interrupted time-series design examined the effect of media attention on physicians' monthly prescribing of opioids. The outcome measures were, for each physician, the monthly proportions of all opioids prescribed and the proportion of strong opioids prescribed that were for oxycodone extended release. The exposure of interest was media attention defined as the number of articles published each month in 27 North American newspapers. Variations in media effects by provider characteristics (specialty, prescribing volume, and region) were assessed. Within-provider changes in the prescribing of oxycodone extended release in Nova Scotia were observed, and they followed changes in media coverage. Oxycodone extended release prescribing rose steadily prior to receiving media attention. Following peak media attention in the United States, the prescribing of oxycodone extended release slowed. Likewise, following peak coverage in Canadian newspapers, the prescribing of oxycodone extended release declined. These patterns were observed across prescriber specialties and by prescriber volume, though the magnitude of change in prescribing varied. This study demonstrates that print media reporting of oxycodone extended release in North American newspapers, and its continued portrayal as a social problem, coincided with reductions in the prescribing of oxycodone extended release by physicians in Nova Scotia. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.

  6. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): Concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology

    International Nuclear Information System (INIS)

    Poetter, Richard; Haie-Meder, Christine; Limbergen, Erik van; Barillot, Isabelle; Brabandere, Marisol De; Dimopoulos, Johannes; Dumas, Isabelle; Erickson, Beth; Lang, Stefan; Nulens, An; Petrow, Peter; Rownd, Jason; Kirisits, Christian

    2006-01-01

    The second part of the GYN GEC ESTRO working group recommendations is focused on 3D dose-volume parameters for brachytherapy of cervical carcinoma. Methods and parameters have been developed and validated from dosimetric, imaging and clinical experience from different institutions (University of Vienna, IGR Paris, University of Leuven). Cumulative dose volume histograms (DVH) are recommended for evaluation of the complex dose heterogeneity. DVH parameters for GTV, HR CTV and IR CTV are the minimum dose delivered to 90 and 100% of the respective volume: D90, D100. The volume, which is enclosed by 150 or 200% of the prescribed dose (V150, V200), is recommended for overall assessment of high dose volumes. V100 is recommended for quality assessment only within a given treatment schedule. For Organs at Risk (OAR) the minimum dose in the most irradiated tissue volume is recommended for reporting: 0.1, 1, and 2 cm 3 ; optional 5 and 10 cm 3 . Underlying assumptions are: full dose of external beam therapy in the volume of interest, identical location during fractionated brachytherapy, contiguous volumes and contouring of organ walls for >2 cm 3 . Dose values are reported as absorbed dose and also taking into account different dose rates. The linear-quadratic radiobiological model-equivalent dose (EQD 2 )-is applied for brachytherapy and is also used for calculating dose from external beam therapy. This formalism allows systematic assessment within one patient, one centre and comparison between different centres with analysis of dose volume relations for GTV, CTV, and OAR. Recommendations for the transition period from traditional to 3D image-based cervix cancer brachytherapy are formulated. Supplementary data (available in the electronic version of this paper) deals with aspects of 3D imaging, radiation physics, radiation biology, dose at reference points and dimensions and volumes for the GTV and CTV (adding to [Haie-Meder C, Poetter R, Van Limbergen E et al

  7. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  8. Estimation of the minimum dose required to measure ventricular width in follow-up cranial computed tomography (CCT) in children with hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Kirchhof, K. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Wohlgemuth, W.A.; Berlis, A. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie

    2010-12-15

    Purpose: To estimate the minimum dose needed at follow-up cranial computed tomography (CCT) to reliably determine ventricular width in children with hydrocephalus. Materials and Methods: For the study, a phantom was created using the calvarium of an infant which was filled with gelatin and the shaped inner cones of two carrots serving as lateral ventricles. The phantom was scanned ten times with two multi-slice CTs (LightSpeed Ultra, GE, and Somatom Sensation, Siemens), using a tube current of 400, 350, 300, 250, 200, 150, and 100 mA, and a tube voltage of 140, 120, 100, and 80 kV. The width of both lateral ventricles was measured at 4 sites. The values derived from scans performed at 380 / 400 mA and 140 kV (LightSpeed/Somatom) served as a reference. Measurements scored 1 point if they did not differ by more than 0.5 mm from the reference values. Results: The radiation dose can be reduced from 61.0 mGy to 9.2 mGy (15.1 %) with LightSpeed and from 55.0 mGy to 8.0 mGy (14.6 %) with Somatom without impairing the reliability of ventricular width measurements. However, in the case of both scanners, certain combinations of tube voltage and current yielded less reliable measurements although the dose was higher and the pixel noise was lower. Conclusion: There is no single cut-off dose or setting for tube voltage and current which guarantees reliable ventricular width measurements with the least radiation exposure for both scanners. As a guideline, it is safe to use the standard protocols with a reduced tube current of 100 kV. (orig.)

  9. Minimum monitor unit per segment IMRT planning and over-shoot-ratio

    International Nuclear Information System (INIS)

    Grigorov, G.; Barnett, R.; Chow, J.

    2004-01-01

    The aim of this work is to describe the modulation quality for dose delivery of small Multi-Leaf Collimator (MLC) fields and MU/segment. The results were obtained with Pinnacle (V6) and a Varian Clinac 2100 EX (Varis 6.2) linear accelerator. The over-shoot effect was investigated by comparing integrated multiple segmented exposures to a single exposure with the same number of total MU (1, 2, 3,4, 5 and 6 MU). To present the OS effect the Over-Shoot-Ratio (OSR) was defined as the ratio of the segmented dose for a 1 cm 2 field at depth to the static dose for the same field size and depth. OSR was measured as a function of MU/segment and dose rate. Measured results can be used to optimise IMRT planning and also to calculate the surface dose. The dependence of the dose in depth with 1, 2, 3, 4, and 5 MU/segments for 6 MV photon beam, dose rate of 100 MU/min and 1 cm 2 beam field at the central axis is presented, where the argument of the function is the depth and parameter of the function is the number of minimum MU/segment. The dependence of the overshoot ratio on the MU/segment with a parameter of the dose rates (100, 400 and 600 MU/min) is also shown. The effect increases with the dose rate and decreases with the increasing of the minimum number of MU/segment. Having measured OSR for the 2100 EX linac it is possible to do correction and calibration of the dose of the first segment of IMRT beam, where the dose to the target and on the surface can increase over the planed dose of 1 MU by 40% and 70% for dose rate of 400 and 600 MU/min respectively. The Over-Shoot-Ratio is an important parameter to be determined as part of the routine quality assurance for IMRT and can be used to significantly improve the agreement between planned and delivered doses to the patient

  10. Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.; Dorsey, Anthony T.; Hagedorn, Brenda M.

    2000-01-01

    Purpose: To determine the magnitude of the differences between urethral dose-volume, dose-area, and dose-length histograms (DVH, DAH, and DLH, respectively, or DgH generically). Methods and Materials: Six consecutive iodine-125 ( 125 I) patients and 6 consecutive palladium-103 ( 103 Pd) patients implanted via a modified uniform planning approach were evaluated with day 0 computed tomography (CT)-based dosimetry. The urethra was identified by the presence of a urinary catheter and was hand drawn on the CT images with a mean radius of 3.3 ± 0.7 mm. A 0.1-mm calculation matrix was employed for the urethral volume and surface analysis, and urethral dose points were placed at the centroid of the urethra on each 5-mm CT slice. Results: Although individual patient DLHs were step-like, due to the sparseness of the data points, the composite urethral DLH, DAH, and DVHs were qualitatively similar. The DAH curve delivered more radiation than the other two curves at all doses greater than 90% of the prescribed minimum peripheral dose (mPD) to the prostate. In addition, the DVH curve was consistently higher than the DLH curve at most points throughout that range. Differences between the DgH curves were analyzed by integrating the difference curves between 0 and 200% of the mPD. The area-length, area-volume, and volume-length difference curves integrated in the ratio of 3:2:1. The differences were most pronounced near the inflection point of the DgH curves with mean A 125 , V 125 , and L 125 values of 36.6%, 31.4%, and 23.0%, respectively, of the urethra. Quantifiers of urethral hot spots such as D 10 , defined as the minimal dose delivered to the hottest 10% of the urethra, followed the same ranking: area analysis indicated the highest dose and length analysis, the lowest dose. D 10 was 148% and 136% of mPD for area and length evaluations, respectively. Comparing the two isotopes in terms of the amount of urethra receiving a given dose, 103 Pd implants were significantly

  11. Direct measurement of dose at depth in breast cancer using lithium fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Dawes, P J.D.K.; Aird, E G; Crawshaw, I P

    1988-05-01

    In 23 cases of breast cancer treated conservatively using external beam and interstitial radiotherapy, lithium fluoride thermoluminescent dosimetry has been used to measure the radiation dose received by the breast tissue at depth. Thirty-six investigations were made using a number of lithium fluoride micro-rods for each investigation. Three results could not be analysed because of measurement problems in two and insufficient information in one. Twenty-eight results were obtained at a depth in tissue greater than the build-up zone, 23 of the 28 falling within +- 5% and 27 of the 28 falling within +- 10% of the computer-calculated prescribed dose. Of five results obtained within the build-up zone, two fell within +- 5% and four within +- 10% of the prescribed dose.

  12. Organ doses and effective doses in some medical and industrial applications

    International Nuclear Information System (INIS)

    Keshavkumar, Biju

    2000-01-01

    The ICRP recommends radiation protection standards for the safe use of radiation and also prescribes the radiation protection quantities and periodically reviews them. In this context, the quantities like organ doses and effective doses are defined by ICRP. In this work we calculate these quantities and hence the conversion functions for the industrial radiation sources and those for CT and diagnostic X-ray exposures. Workers who are occupationally exposed to radiation are regularly monitored to evaluate the radiation dose received by them. It is quite possible that in an accident situation, the worker involved in the accident might not have worn a personal monitor, popularly known as the monitoring badge. In addition, even some non radiation workers (who are obviously not monitored) may also have received exposure. Under these circumstances, the persons involved are interviewed, the accident site inspected, and on the basis of realistic assumptions, the likely doses received by the exposed persons are estimated

  13. Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

    OpenAIRE

    Dobrescu, Lidia; Rădulescu, Gheorghe-Cristian

    2015-01-01

    The paper presents many facets of medical imaging investigations radiological risks. The total volume of prescribed medical investigations proves a serious lack in monitoring and tracking of the cumulative radiation doses in many health services. Modern radiological investigations equipment is continuously reducing the total dose of radiation due to improved technologies, so a decrease in per caput dose can be noticed, but the increasing number of investigations has determined a net increase ...

  14. A RCT evaluating the effectiveness and cost-effectiveness of academic detailing versus postal prescribing feedback in changing GP antibiotic prescribing.

    LENUS (Irish Health Repository)

    Naughton, Corina

    2009-10-01

    The aim of this study is to evaluate the effectiveness of academic detailing (AD) plus postal prescribing feedback versus postal prescribing feedback alone in reducing: (i) the overall rate of antibiotic; and (ii) proportion of second-line antibiotic prescribing. In addition, the cost-effectiveness of an outreach prescriber adviser service versus a postal prescribing feedback service was evaluated.

  15. Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Samantha, E-mail: Samantha.warren@oncology.ox.ac.uk [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Panettieri, Vanessa [William Buckland Radiotherapy Centre, Alfred Hospital, Commercial Road, Melbourne (Australia); Panakis, Niki; Bates, Nicholas [Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Lester, Jason F. [Velindre Cancer Centre, Velindre Road, Whitchurch, Cardiff (United Kingdom); Jain, Pooja [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Landau, David B. [Department of Radiotherapy, Guy' s and St. Thomas' NHS Foundation Trust, London (United Kingdom); Nahum, Alan E.; Mayles, W. Philip M. [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Fenwick, John D. [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom)

    2014-04-01

    Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

  16. Controlled Substance Prescribing Patterns--Prescription Behavior Surveillance System, Eight States, 2013.

    Science.gov (United States)

    Paulozzi, Leonard J; Strickler, Gail K; Kreiner, Peter W; Koris, Caitlin M

    2015-10-16

    Drug overdose is the leading cause of injury death in the United States. The death rate from drug overdose in the United States more than doubled during 1999-2013, from 6.0 per 100,000 population in 1999 to 13.8 in 2013. The increase in drug overdoses is attributable primarily to the misuse and abuse of prescription drugs, especially opioid analgesics, sedatives/tranquilizers, and stimulants. Such drugs are prescribed widely in the United States, with substantial variation by state. Certain patients obtain drugs for nonmedical use or resale by obtaining overlapping prescriptions from multiple prescribers. The risk for overdose is directly associated with the use of multiple prescribers and daily dosages of >100 morphine milligram equivalents (MMEs) per day. 2013. The Prescription Behavior Surveillance System (PBSS) is a public health surveillance system that allows public health authorities to characterize and quantify the use and misuse of prescribed controlled substances. PBSS began collecting data in 2012 and is funded by CDC and the Food and Drug Administration. PBSS uses standard metrics to measure prescribing rates per 1,000 state residents by demographic variables, drug type, daily dose, and source of payment. Data from the system can be used to calculate rates of misuse by certain behavioral measures such as use of multiple prescribers and pharmacies within specified time periods. This report is based on 2013 de-identified data (most recent available) that represent approximately one fourth of the U.S. Data were submitted quarterly by prescription drug monitoring programs (PDMPs) in eight states (California, Delaware, Florida, Idaho, Louisiana, Maine, Ohio, and West Virginia) that routinely collect data on every prescription for a controlled substance to help law enforcement and health care providers identify misuse or abuse of such drugs. In all eight states, opioid analgesics were prescribed approximately twice as often as stimulants or benzodiazepines

  17. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products; Sistemas dosimetricos de altas dosis, tasa de dosis y uniformidad de dosis en alimentos y producto medico

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.; Vivanco, M.; Castro, E., E-mail: jvargas@ipen.gob.pe [Instituto Peruano de Energia Nuclear, Av. Canada 1470, San Borja, Lima (Peru)

    2014-08-15

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  18. Improving antimicrobial prescribing in Irish primary care through electronic data collection and surveillance: a feasibility study.

    Science.gov (United States)

    Galvin, Sandra; Callan, Aoife; Cormican, Martin; Duane, Sinead; Bennett, Kathleen; Murphy, Andrew W; Vellinga, Akke

    2015-07-02

    The increase in the spread of antimicrobial resistance (AMR) in bacterial pathogens and limited availability of new antimicrobials places immense pressure on general practitioners (GPs) to prescribe appropriately. Currently, electronic antimicrobial prescribing data is not routinely collected from GPs in Ireland for surveillance purposes to assess regional specific fluctuations or trends in antimicrobial prescribing. The current study aimed to address this issue by assessing the feasibility of remotely extracting antimicrobial prescribing data from primary care practices in Ireland, for the purpose of assessing prescribing quality using the European Surveillance of Antimicrobial Consumption (ESAC) drug specific quality indicators. Participating practices (n = 30) uploaded data to the Irish Primary Care Research Network (IPCRN). The IPCRN data extraction facility is integrated within the practice patient management software system and permitted the extraction of anonymised patient prescriptions for a one year period, from October 2012 to October 2013. The quality of antimicrobial prescribing was evaluated using the twelve ESAC drug specific quality indicators using the defined daily dose (DDD) per 1,000 inhabitants per day (DID) methodology. National and European prescribing surveillance data (based on total pharmacy sales) was obtained for a comparative analysis. Antimicrobial prescriptions (n = 57,079) for 27,043 patients were obtained from the thirty study practices for a one year period. On average, study practices prescribed a greater proportion of quinolones (37 % increase), in summer compared with winter months, a variation which was not observed in national and European data. In comparison with national data, study practices prescribed higher proportions of β-lactamase-sensitive penicillins (4.98 % vs. 4.3 %) and a greater use of broad spectrum compared to narrow-spectrum antimicrobials (ratio = 9.98 vs. 6.26) was observed. Study practices exceeded the

  19. Retrospective analysis of dose delivery in intra-operative high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Oh, M.; Avadhani, J.S.; Malhotra, H.K.; Cunningham, B.; Tripp, P.; Jaggernauth, W.; Podgorsak, M.B.

    2007-01-01

    Background. This study was performed to quantify the inaccuracy in clinical dose delivery due to the incomplete scatter conditions inherent in intra-operative high dose rate (IOHDR) brachytherapy. Methods. Treatment plans of 10 patients previously treated in our facility, which had irregular shapes of treated areas, were used. Treatment geometries reflecting each clinical case were simulated using a phantom assembly with no added build-up on top of the applicator. The treatment planning geometry (full scatter surrounding the applicator) was subsequently simulated for each case by adding bolus on top of the applicator. Results. For geometries representing the clinical IOHDR incomplete scatter environment, measured doses at the 5 mm and 10 mm prescription depths were lower than the corresponding prescribed doses by about 7.7% and 11.1%, respectively. Also, for the two prescription methods, an analysis of the measured dose distributions and their corresponding treatment plans showed average decreases of 1.2 mm and 2.2 mm in depth of prescription dose, respectively. Conclusions. Dosimetric calculations with the assumption of an infinite scatter environment around the applicator and target volume have shown to result in dose delivery errors that significantly decrease the prescription depth for IOHDR treatment.(author)

  20. Dosimetric evaluation of the impacts of different heterogeneity correction algorithms on target doses in stereotactic body radiation therapy for lung tumors

    International Nuclear Information System (INIS)

    Narabayashi, Masaru; Mizowaki, Takashi; Matsuo, Yukinori; Nakamura, Mitsuhiro; Takayama, Kenji; Norihisa, Yoshiki; Sakanaka, Katsuyuki; Hiraoka, Masahiro

    2012-01-01

    Heterogeneity correction algorithms can have a large impact on the dose distributions of stereotactic body radiation therapy (SBRT) for lung tumors. Treatment plans of 20 patients who underwent SBRT for lung tumors with the prescribed dose of 48 Gy in four fractions at the isocenter were reviewed retrospectively and recalculated with different heterogeneity correction algorithms: the pencil beam convolution algorithm with a Batho power-law correction (BPL) in Eclipse, the radiological path length algorithm (RPL), and the X-ray Voxel Monte Carlo algorithm (XVMC) in iPlan. The doses at the periphery (minimum dose and D95) of the planning target volume (PTV) were compared using the same monitor units among the three heterogeneity correction algorithms, and the monitor units were compared between two methods of dose prescription, that is, an isocenter dose prescription (IC prescription) and dose-volume based prescription (D95 prescription). Mean values of the dose at the periphery of the PTV were significantly lower with XVMC than with BPL using the same monitor units (P<0.001). In addition, under IC prescription using BPL, RPL and XVMC, the ratios of mean values of monitor units were 1, 0.959 and 0.986, respectively. Under D95 prescription, they were 1, 0.937 and 1.088, respectively. These observations indicated that the application of XVMC under D95 prescription results in an increase in the actually delivered dose by 8.8% on average compared with the application of BPL. The appropriateness of switching heterogeneity correction algorithms and dose prescription methods should be carefully validated from a clinical viewpoint. (author)

  1. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1997-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume -- Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) -- Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  2. Physics and quality assurance for brachytherapy - Part II: Low dose rate and pulsed dose rate

    International Nuclear Information System (INIS)

    Williamson, Jeffrey F.

    1996-01-01

    Purpose: A number of recent developments have revitalized brachytherapy including remote afterloading, implant optimization, increasing use of 3D imaging, and advances in dose specification and basic dosimetry. However, the core physical principles underlying the classical methods of dose calculation and arrangement of multiple sources remain unchanged. The purpose of this course is to review these principles and their applications to low dose-rate interstitial and intracavitary brachytherapy. Emphasis will be placed upon the classical implant systems along with classical and modern methods of dose specification. The level of presentation is designed for radiation oncology residents and beginning clinical physicists. A. Basic Principles (1) Radium-substitute vs. low-energy sealed sources (2) Dose calculation principles (3) The mysteries of source strength specification revealed: mgRaEq, mCi and air-kerma strength B. Interstitial Brachytherapy (1) Target volume, implanted volume, dose specification in implants and implant optimization criteria (2) Classical implant systems: Manchester Quimby and Paris a) Application of the Manchester system to modern brachytherapy b) Comparison of classical systems (3) Permanent interstitial implants a) Photon energy and half life b) Dose specification and pre-operative planning (4) The alphabet soup of dose specification: MCD (mean central dose), minimum dose, MPD (matched peripheral dose), MPD' (minimum peripheral dose) and DVH (dose-volume histogram) quality indices C. Intracavitary Brachytherapy for Carcinoma of the Cervix (1) Basic principles a) Manchester System: historical foundation of U.S. practice patterns b) Principles of applicator design (2) Dose specification and treatment prescription a) mg-hrs, reference points, ICRU Report 38 reference volume --Point A dose vs mg-hrs and IRAK (Integrated Reference Air Kerma) --Tissue volume treated vs mg-hrs and IRAK b) Practical methods of treatment specification and prescription

  3. Health Canada Warning on Citalopram and Escitalopram--Its Effects on Prescribing in Consultation-Liaison Psychiatry.

    Science.gov (United States)

    Do, André; Noohi, Saeid; Elie, Dominique; Mahdanian, Artin A; Yu, Ching; Segal, Marilyn; Looper, Karl J; Rej, Soham

    2016-01-01

    Reports have suggested that citalopram and escitalopram may prolong the QTc interval, leading Health Canada to issue a warning to limit their dosages in 2012. Little is known about the effects of this warning and similar ones (e.g., by the Food and Drug Administration) on antidepressant prescribing in inpatients with acute medical illness, who are theoretically at high risk of QTc prolongation. The main objective of our study is to examine the effect of the Health Canada warning on citalopram/escitalopram prescribing patterns in the consultation-liaison (C-L) psychiatry setting. We performed a retrospective cohort study including 275 randomly selected inpatients with medical illness assessed by the psychiatric C-L team of a large Canadian academic hospital between 2008 and 2014. We grouped patients based on whether they were assessed by the C-L team before or after the citalopram Health Canada warning. Our primary outcome was change in citalopram/escitalopram prescribing patterns. We found that of patients seen before the Health Canada warning, a significantly higher number were prescribed citalopram/escitalopram (44.1% vs. 22.3%, χ(2) = 14.835, p Canada warning was similar in both groups (8.9% vs. 12.1%, χ(2) = 0.233, p = 0.63). Overall, C-L psychiatrists were less likely to prescribe citalopram/escitalopram following the Health Canada warning, which did not translate into safer dosing. Clinicians should not avoid prescribing citalopram/escitalopram appropriately in medically vulnerable inpatients when benefits outweigh disadvantages. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  4. Should we routinely remove the dose delivered by the images of control?; Faut-il systematiquement retirer la dose delivree par les images de controle?

    Energy Technology Data Exchange (ETDEWEB)

    Goasduff, G. [Centre Hospitalier Universitaire Morvan, Service de Radiotherapie, 29 - Brest (France); Pene Baverez, D.; Pradier, O.; Bouchekoua, M. [Service de Radiotherapie, 29 - Brest (France)

    2009-10-15

    The constraints of doses fixed by the international commission on radiation units and measurements (ICRU) for the target volume (95-107% of the prescribed dose) are respected. for the hypo fractionated treatments, it is necessary to control the impact of the dose delivered by the control images for every patient. The dose delivered at the isocenter is estimated between 1 and 3 Gy by control image: this dose depends on the beams size and on the distance-source-skin. Protocols of the patient positioning checking must be implemented on optimizing their frequency to limit the dose received by the patient. (N.C.)

  5. Implementing nurse prescribing: a case study in diabetes.

    Science.gov (United States)

    Stenner, Karen; Carey, Nicola; Courtenay, Molly

    2010-03-01

    This paper is a report of a study exploring the views of nurses and team members on the implementation of nurse prescribing in diabetes services. Nurse prescribing is adopted as a means of improving service efficiency, particularly where demand outstretches resources. Although factors that support nurse prescribing have been identified, it is not known how these function within specific contexts. This is important as its uptake and use varies according to mode of prescribing and area of practice. A case study was undertaken in nine practice settings across England where nurses prescribed medicines for patients with diabetes. Thematic analysis was conducted on qualitative data from 31 semi-structured interviews undertaken between 2007 and 2008. Participants were qualified nurse prescribers, administrative staff, physicians and non-nurse prescribers. Nurses prescribed more often following the expansion of nurse independent prescribing rights in 2006. Initial implementation problems had been resolved and few current problems were reported. As nurses' roles were well-established, no major alterations to service provision were required to implement nurse prescribing. Access to formal and informal resources for support and training were available. Participants were accepting and supportive of this initiative to improve the efficiency of diabetes services. The main factors that promoted implementation of nurse prescribing in this setting were the ability to prescribe independently, acceptance of the prescribing role, good working relationships between doctors and nurses, and sound organizational and interpersonal support. The history of established nursing roles in diabetes care, and increasing service demand, meant that these diabetes services were primed to assimilate nurse prescribing.

  6. Prescribing for Children With Rheumatic Disease: Perceived Treatment Approaches Between Pediatric and Adult Rheumatologists.

    Science.gov (United States)

    van Mater, Heather; Balevic, Stephen J; Freed, Gary L; Clark, Sarah J

    2018-02-01

    To compare practice patterns and prescribing differences for juvenile idiopathic arthritis (JIA) between adult rheumatologists (ARs) and pediatric rheumatologists (PRs), the perceived educational needs, and factors that enhance or impede co-management. Two parallel, cross-sectional surveys focusing on JIA were administered in 2009 to a random sample of 193 PRs and 500 ARs using the American College of Rheumatology membership file. Bivariate analysis was conducted for common items. The response rate was 62.1% for ARs (n = 306) and 72.3% for PRs (n = 138). Only 23% of responding ARs (n = 69) reported caring for children with JIA. Of these, 94% strongly agreed/agreed feeling comfortable diagnosing JIA; however, only 76% felt comfortable treating JIA. Clinical vignettes highlighted several prescribing differences. Forty-eight percent of ARs and 31% of PRs felt medications to treat JIA did not have clear dosing guidelines. Though PRs initiated disease-modifying antirheumatic drugs and biologic agents earlier, treatments were similar after 3 months. To enhance co-management, 74% of pediatric respondents endorsed shared medical records. Nearly one-quarter of surveyed ARs care for children with JIA, with most limiting their practice to older children. There was more discomfort in treating JIA than diagnosing it, and there were significant prescribing differences. Both provider types identified the need for better dosing and treatment resources. Updated management guidelines along with exposure to pediatric rheumatology in fellowship could reduce treatment differences and enhance the care of children with JIA. Shared medical records and improvement in reimbursement may optimize co-management. © 2017, American College of Rheumatology.

  7. Targeting the adventitia with intracoronary beta-radiation: comparison of two dose prescriptions and the role of centering coronary arteries

    International Nuclear Information System (INIS)

    Kaluza, Grzegorz L.; Jenkins, Todd P.; Mourtada, Firas A.; Ali, Nadir M.; Lee, David P.; Okura, Hiroyuki; Fitzgerald, Peter J.; Raizner, Albert E.

    2002-01-01

    Purpose: To compare by intravascular ultrasound (IVUS) the efficacy of delivering the prescribed dose to the adventitia between two commonly used dose prescriptions for intracoronary radiotherapy. Methods and Materials: In 59 human postangioplasty coronary vessels, one IVUS cross-section (1 mm thick) with the highest plaque burden was used for creating dose-volume histograms with different hypothetical positions of the source. Results: On average, prescription to 1 mm beyond lumen surface resulted in delivery of the prescribed dose (20 Gy ± 20%) to a higher fraction of adventitial volume than with the prescription to 2 mm from the source, with source placed in vessel center, lumen center, or in the IVUS catheter position. Source placement in the lumen center resulted in a low dose heterogeneity to the adventitia and the least dose heterogeneity to the intima. Conclusions: Prescription to 1 mm beyond lumen surface appeared more effective in delivering the prescribed dose to the adventitia than the American Association of Physicists in Medicine (AAPM) recommended prescription to 2 mm from the source center. Moreover, centering the source in the lumen provides the better balance of effective adventitial targeting and intimal dose homogeneity. Modification of the current AAPM recommendation for dose prescription for intracoronary radiotherapy should be considered

  8. Multi-isocenter stereotactic radiotherapy: implications for target dose distributions of systematic and random localization errors

    International Nuclear Information System (INIS)

    Ebert, M.A.; Zavgorodni, S.F.; Kendrick, L.A.; Weston, S.; Harper, C.S.

    2001-01-01

    Purpose: This investigation examined the effect of alignment and localization errors on dose distributions in stereotactic radiotherapy (SRT) with arced circular fields. In particular, it was desired to determine the effect of systematic and random localization errors on multi-isocenter treatments. Methods and Materials: A research version of the FastPlan system from Surgical Navigation Technologies was used to generate a series of SRT plans of varying complexity. These plans were used to examine the influence of random setup errors by recalculating dose distributions with successive setup errors convolved into the off-axis ratio data tables used in the dose calculation. The influence of systematic errors was investigated by displacing isocenters from their planned positions. Results: For single-isocenter plans, it is found that the influences of setup error are strongly dependent on the size of the target volume, with minimum doses decreasing most significantly with increasing random and systematic alignment error. For multi-isocenter plans, similar variations in target dose are encountered, with this result benefiting from the conventional method of prescribing to a lower isodose value for multi-isocenter treatments relative to single-isocenter treatments. Conclusions: It is recommended that the systematic errors associated with target localization in SRT be tracked via a thorough quality assurance program, and that random setup errors be minimized by use of a sufficiently robust relocation system. These errors should also be accounted for by incorporating corrections into the treatment planning algorithm or, alternatively, by inclusion of sufficient margins in target definition

  9. Psychiatric Prescribers' Experiences With Doctor Shoppers.

    Science.gov (United States)

    Worley, Julie; Johnson, Mary; Karnik, Niranjan

    2015-01-01

    Doctor shopping is a primary method of prescription medication diversion. After opioids, benzodiazepines and stimulants are the next most common prescription medications used nonmedically. Studies have shown that patients who engage in doctor shopping find it fun, exciting, and easy to do. There is a lack of research on the prescriber's perspective on the phenomenon of doctor shopping. This study investigates the experiences of prescribers in psychiatry with patients who engage in doctor shopping. Fifteen prescribers including psychiatrists and psychiatric nurse practitioners working in outpatient psychiatry were interviewed to elicit detailed information about their experiences with patients who engage in doctor shopping. Themes found throughout the interview were that psychiatric prescribers' experience with patients who engage in doctor shopping includes (a) detecting red flags, (b) negative emotional responding, (c) addressing the patient and the problem, and (d) inconsistently implementing precautions. When red flags were detected when prescribing controlled drugs, prescribers in psychiatry experienced both their own negative emotional responses such as disappointment and resentment as well as the negative emotions of the patients such as anger and other extreme emotional responses. Psychiatric prescribers responded to patient's doctor shopping in a variety of ways such as changing their practice, discharging the patients or taking steps to not accept certain patients identified as being at risk for doctor shopping, as well as by talking to the patient and trying to offer them help. Despite experiencing doctor shopping, the prescribers inconsistently implemented precautionary measures such as checking prescription drug monitoring programs. © The Author(s) 2015.

  10. Parotid gland tumors: A comparison of postoperative radiotherapy techniques using three dimensional (3D) dose distributions and dose-volume histograms (DVHs)

    International Nuclear Information System (INIS)

    Yaparpalvi, Ravindra; Fontenla, Doracy P.; Tyerech, Sangeeta K.; Boselli, Lucia R.; Beitler, Jonathan J.

    1998-01-01

    Purpose: To compare different treatment techniques for unilateral treatment of parotid gland tumors. Methods and Materials: The CT-scans of a representative parotid patient were used. The field size was 9 x 11 cm, the separation was 15.5 cm, and the prescription depth was 4.5 cm. Using 3D dose distributions, tissue inhomogeneity corrections, scatter integration (for photons) and pencil beam (for electrons) algorithms and dose-volume histogram (DVH), nine treatment techniques were compared. [1] unilateral 6 MV photons [2] unilateral 12 MeV electrons [3] unilateral 16 MeV electrons [4] an ipsilateral wedge pair technique using 6 MV photons [5] a 3-field AP (wedged), PA (wedged) and lateral portal technique using 6 MV photons [6] a mixed beam technique using 6 MV photons and 12 MeV electrons (1:4 weighting) [7] a mixed beam technique using 6 MV photons and 16 MeV electrons (1:4 weighting) [8] a mixed beam technique using 18 MV photons and 20 MeV electrons (2:3 weighting) [9] a mixed beam technique using 18 MV photons and 20 MeV electrons (1:1 weighting). Results: Using dose-volume histograms to evaluate the dose to the contralateral parotid gland, the percentage of contralateral parotid volume receiving ≥ 30% of the prescribed dose was 100% for techniques [1], [8] and [9], and < 5% for techniques [2] through [7]. Evaluating the 'hottest' 5 cc of the ipsilateral mandible and temporal lobes, the hot spots were: 152% and 150% for technique [2], 132% and 130% for technique [6]. Comparing the exit doses, techniques [1], [8] and [9] contributed to ≥ 50% of the prescribed dose to the contralateral mandible and the temporal lobes. Only techniques [2] and [6] kept the highest point doses to both the brain stem and the spinal cord below 50% of the prescribed dose. Conclusion: The single photon lateral field [1] and the mixed electron-photon beams [8] and [9] are not recommended treatment techniques for unilateral parotid irradiation because of high doses delivered to the

  11. A model of methods for influencing prescribing: Part I. A review of prescribing models, persuasion theories, and administrative and educational methods.

    Science.gov (United States)

    Raisch, D W

    1990-04-01

    The purpose of this literature review is to develop a model of methods to be used to influence prescribing. Four bodies of literature were identified as being important for developing the model: (1) Theoretical prescribing models furnish information concerning factors that affect prescribing and how prescribing decisions are made. (2) Theories of persuasion provide insight into important components of educational communications. (3) Research articles of programs to improve prescribing identify types of programs that have been found to be successful. (4) Theories of human inference describe how judgments are formulated and identify errors in judgment that can play a role in prescribing. This review is presented in two parts. This article reviews prescribing models, theories of persuasion, studies of administrative programs to control prescribing, and sub-optimally designed studies of educational efforts to influence drug prescribing.

  12. Automation bias in electronic prescribing.

    Science.gov (United States)

    Lyell, David; Magrabi, Farah; Raban, Magdalena Z; Pont, L G; Baysari, Melissa T; Day, Richard O; Coiera, Enrico

    2017-03-16

    Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB. One hundred and twenty students in the final two years of a medical degree prescribed medicines for nine clinical scenarios using a simulated e-prescribing system. Quality of CDS (correct, incorrect and no CDS) and task complexity (low, low + interruption and high) were varied between conditions. Omission errors (failure to detect prescribing errors) and commission errors (acceptance of false positive alerts) were measured. Compared to scenarios with no CDS, correct CDS reduced omission errors by 38.3% (p < .0001, n = 120), 46.6% (p < .0001, n = 70), and 39.2% (p < .0001, n = 120) for low, low + interrupt and high complexity scenarios respectively. Incorrect CDS increased omission errors by 33.3% (p < .0001, n = 120), 24.5% (p < .009, n = 82), and 26.7% (p < .0001, n = 120). Participants made commission errors, 65.8% (p < .0001, n = 120), 53.5% (p < .0001, n = 82), and 51.7% (p < .0001, n = 120). Task complexity and interruptions had no impact on AB. This study found evidence of AB omission and commission errors in e-prescribing. Verification of CDS alerts is key to avoiding AB errors. However, interventions focused on this have had limited success to date. Clinicians should remain vigilant to the risks of CDS failures and verify CDS.

  13. Inappropriate prescribing in the elderly.

    LENUS (Irish Health Repository)

    Gallagher, P

    2012-02-03

    BACKGROUND AND OBJECTIVE: Drug therapy is necessary to treat acute illness, maintain current health and prevent further decline. However, optimizing drug therapy for older patients is challenging and sometimes, drug therapy can do more harm than good. Drug utilization review tools can highlight instances of potentially inappropriate prescribing to those involved in elderly pharmacotherapy, i.e. doctors, nurses and pharmacists. We aim to provide a review of the literature on potentially inappropriate prescribing in the elderly and also to review the explicit criteria that have been designed to detect potentially inappropriate prescribing in the elderly. METHODS: We performed an electronic search of the PUBMED database for articles published between 1991 and 2006 and a manual search through major journals for articles referenced in those located through PUBMED. Search terms were elderly, inappropriate prescribing, prescriptions, prevalence, Beers criteria, health outcomes and Europe. RESULTS AND DISCUSSION: Prescription of potentially inappropriate medications to older people is highly prevalent in the United States and Europe, ranging from 12% in community-dwelling elderly to 40% in nursing home residents. Inappropriate prescribing is associated with adverse drug events. Limited data exists on health outcomes from use of inappropriate medications. There are no prospective randomized controlled studies that test the tangible clinical benefit to patients of using drug utilization review tools. Existing drug utilization review tools have been designed on the basis of North American and Canadian drug formularies and may not be appropriate for use in European countries because of the differences in national drug formularies and prescribing attitudes. CONCLUSION: Given the high prevalence of inappropriate prescribing despite the widespread use of drug-utilization review tools, prospective randomized controlled trials are necessary to identify useful interventions. Drug

  14. Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure

    International Nuclear Information System (INIS)

    Paul, Jijo; Vogl, Thomas J; Chacko, Annamma; Mbalisike, Emmanuel C

    2014-01-01

    Cone-beam computed tomography (CBCT) imaging is an important requirement to perform real-time therapeutic image-guided procedures on patients. The purpose of this study is to estimate the personal-dose-equivalent and annual-personal-dose from CBCT imaging during transarterial chemoembolisation (TACE). Therapeutic staff doses (therapeutic and assistant physician) were collected during 200 patient (65  ±  15 years, range: 40–86) CBCT examinations over six months. Absorbed doses were assessed using thermo-luminescent dosimeters during patient hepatic TACE therapy. We estimated personal-dose-equivalent (PDE) and annual-personal-dose (APD) from absorbed dose based on international atomic energy agency protocol. APD for therapeutic procedure was calculated (therapeutic physician: 5.6 mSv; assistant physician: 5.08 mSv) based on institutional work load. Regarding PDE, the hands of the staff members received a greater dose compared to other anatomical locations (therapeutic physician: 56 mSv, 72 mSv; assistant physician: 12 mSv, 14 mSv). Annual radiation doses to the eyes and hands of the staff members were lower compared to the prescribed limits by the International Commission on Radiological Protection (ICRP). PDE and APD of both therapeutic staff members were within the recommended ICRP-103 annual limit. Dose to the assistant physician was lower than the dose to the therapeutic physician during imaging. Annual radiation doses to eye-lenses and hands of both staff members were lower than prescribed limits. (paper)

  15. Clinical radiation doses for spinal cord: the 1988 international questionnaire

    International Nuclear Information System (INIS)

    Fowler, J.F.; Bogaert, W. vanden; Scheuren, E. van der; Bentzen, S.M.; Bond, S.J.; Ang, K.K.; Kogel, A.J. van der

    2000-01-01

    Emmanuel van der Schueren gave a keynote lecture at the 1988 ASTRO annual conference pointing out that the spinal cord 'tolerance doses' then prescribed were probably unnecessarily cautious, resulting in probable underdosing of some tumours. This lecture was supported both by an international questionnaire which he and two of the present authors had conducted, and by animal experimental data. In 1997 he initiated a 10-year follow-up questionnaire, the results of which are summarised here. The present report analyses the chance in prescriptions from 1988 to 1998 and the variation in prescriptions among various regions of the World. The main conclusion is that prescribed dose levels have increased significantly in this period. Large geographical variations still exist. Among responders who use a formula to correct for changed dose per fraction, 90% are now using the linear-quadratic model vs. 33% in 1988. The current status of clinically acceptable doses to spinal cord in 2-Gy fractions is discussed briefly. Further details from the responses to the 1998 questionnaire will be presented in another publication. (author)

  16. Benzodiazepines - Their role in aggression and why GPs should prescribe with caution.

    Science.gov (United States)

    Jones, Katy A; Nielsen, Suzanne; Bruno, Raimondo; Frei, Matthew; Lubman, Dan I

    2011-11-01

    Benzodiazepines are widely prescribed in Australia, despite concerns about their potential for abuse and dependence. Paradoxical reactions, disinhibition and amnesia are all associated with benzodiazepine use, misuse and intoxication. While violent and aggressive behaviour may be a consequence of such disinhibition, there is limited information available regarding the links between benzodiazepine use and violence. This article aims to examine the existing evidence on the relationship between benzodiazepines, violence and aggression. While current evidence suggests that benzodiazepines rarely induce violence, it is important to note that the available literature is limited in its scope and that benzodiazepine related violence is often severe and of potential concern to frontline workers. Mediating risk factors for benzodiazepine related violence include concurrent alcohol use, benzodiazepine dose, a history of aggression and underlying impulsivity. Comprehensive assessment and alternate nonpharmacological treatment options should be considered before prescribing benzodiazepines within primary care.

  17. Direct measurement of dose at depth in breast cancer using lithium fluoride

    International Nuclear Information System (INIS)

    Dawes, P.J.D.K.; Aird, E.G.; Crawshaw, I.P.

    1988-01-01

    In 23 cases of breast cancer treated conservatively using external beam and interstitial radiotherapy, lithium fluoride thermoluminescent dosimetry has been used to measure the radiation dose received by the breast tissue at depth. Thirty-six investigations were made using a number of lithium fluoride micro-rods for each investigation. Three results could not be analysed because of measurement problems in two and insufficient information in one. Twenty-eight results were obtained at a depth in tissue greater than the build-up zone, 23 of the 28 falling within ± 5% and 27 of the 28 falling within ± 10% of the computer-calculated prescribed dose. Of five results obtained within the build-up zone, two fell within ± 5% and four within ± 10% of the prescribed dose. (author)

  18. Confectionery-based dose forms.

    Science.gov (United States)

    Tangso, Kristian J; Ho, Quy Phuong; Boyd, Ben J

    2015-01-01

    Conventional dosage forms such as tablets, capsules and syrups are prescribed in the normal course of practice. However, concerns about patient preferences and market demands have given rise to the exploration of novel unconventional dosage forms. Among these, confectionery-based dose forms have strong potential to overcome compliance problems. This report will review the availability of these unconventional dose forms used in treating the oral cavity and for systemic drug delivery, with a focus on medicated chewing gums, medicated lollipops, and oral bioadhesive devices. The aim is to stimulate increased interest in the opportunities for innovative new products that are available to formulators in this field, particularly for atypical patient populations.

  19. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks; Doses perifericas de IMRT cranial pediatrica realizada com blocos atenuadores

    Energy Technology Data Exchange (ETDEWEB)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters, E-mail: soboll@utfpr.edu.b, E-mail: iveteschitz@yahoo.com.b, E-mail: schelin@utfpr.edu.b [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Silva, Ricardo Goulart da, E-mail: ricardo.goulart@ymail.co [Hospital Angelina Caron, Campina Grande do Sul, PR (Brazil); Viamonte, Alfredo, E-mail: aviamonte@inca.gov.b [Instituto Nacional do Cancer (INCa), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  20. Parotid gland tumors: a comparison of postoperative radiotherapy techniques using three dimensional (3-D) dose distributions and dose-volume histograms (DVH)

    International Nuclear Information System (INIS)

    Yaparpalvi, R.; Tyerech, S.K.; Boselli, L.R.; Fontenla, D.P.; Beitler, J.J.; Vikram, B.

    1996-01-01

    Purpose/Objective: To compare different treatment techniques for unilateral treatment of parotid gland tumors. Materials and Methods: Twenty patients previously treated postoperatively for parotid gland tumors were retrospectively reviewed. Average field size was 9 x 11 cm, average separation was 15.5 cm, and the average prescription depth was 4.5 cm. Using 3-D dose distributions, tissue inhomogeneity corrections, scatter integration (for photons) and pencil beam (for electrons) algorithms and DVH, nine treatment techniques were compared using a representative patient. The treatment techniques investigated were: [1] unilateral 6 MV photons. [2] unilateral 12 MeV electrons. [3] unilateral 16 MeV electrons. [4] a ipsilateral wedge pair technique using 6 MV photons and a 45-degree wedge. [5] a 3-field AP (wedged), PA (wedged) and lateral portal technique using 6 MV photons. [6] a mixed beam technique using 6 MV photons and 12 MeV electrons (1:4 weighting). [7] a mixed beam technique using 6 MV photons and 16 MeV electrons (1:4 weighting). [8] a mixed beam technique using 18 MV photons and 20 MeV electrons (2:3 weighting). [9] a mixed beam technique using 18 MV photons and 20 MeV electrons (1:1 weighting). Results: Using dose-volume histograms to evaluate the dose to the contralateral parotid gland, the percentage of contralateral parotid volume receiving ≥30% of the prescribed dose was 100% for techniques [1], [8] and [9], and <5% for techniques [2] through [7]. Evaluating the 'hottest' 5 cc of the ipsilateral mandible and temporal lobes, the hot spots were: 152% and 150% for technique [2], 132% and 130% for technique [6]. Comparing the exit doses, techniques [1] and [8] contributed to ≥50% of the prescribed dose to the contralateral mandible and the temporal lobes. Only techniques [2] and [6] kept the highest point doses to both the brain stem and the spinal cord below 50% of the prescribed dose. Conclusion: The single photon lateral field [1] and the mixed

  1. A Dosimetric Comparison of Dose Escalation with Simultaneous Integrated Boost for Locally Advanced Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Wenjuan Yang

    2017-01-01

    Full Text Available Background. Many studies have demonstrated that a higher radiotherapy dose is associated with improved outcomes in non-small-cell lung cancer (NSCLC. We performed a dosimetric planning study to assess the dosimetric feasibility of intensity-modulated radiation therapy (IMRT with a simultaneous integrated boost (SIB in locally advanced NSCLC. Methods. We enrolled twenty patients. Five different dose plans were generated for each patient. All plans were prescribed a dose of 60 Gy to the planning tumor volume (PTV. In the three SIB groups, the prescribed dose was 69 Gy, 75 Gy, and 81 Gy in 30 fractions to the internal gross tumor volume (iGTV. Results. The SIB-IMRT plans were associated with a significant increase in the iGTV dose (P < 0.05, without increased normal tissue exposure or prolonged overall treatment time. Significant differences were not observed in the dose to the normal lung in terms of the V5 and V20 among the four IMRT plans. The maximum dose (Dmax in the esophagus moderately increased along with the prescribed dose (P < 0.05. Conclusions. Our results indicated that escalating the dose by SIB-IMRT is dosimetrically feasible; however, systematic evaluations via clinical trials are still warranted. We have designed a further clinical study (which is registered with ClinicalTrials.gov, number NCT02841228.

  2. A long-term risk-benefit analysis of low-dose aspirin in primary prevention.

    Science.gov (United States)

    Wu, I-Chen; Hsieh, Hui-Min; Yu, Fang-Jung; Wu, Meng-Chieh; Wu, Tzung-Shiun; Wu, Ming-Tsang

    2016-02-01

    The long-term risk-benefit effect of occasional and regular use of low-dose aspirin (≤ 100 mg per day) in primary prevention of vascular diseases and cancers was calculated. One representative database of 1 000 000 participants from Taiwan's National Health Insurance scheme in 1997-2000 was used. The potential study subjects were those aged 30-95 years, were found not to have been prescribed aspirin before 1 January 2000, but to have first been prescribed low-dose aspirin (≤ 100 mg per day) after that date and were followed up to 31 December 2009. Participants prescribed low-dose aspirin risk. A total of 1720 pairs were analysed. During the study period, haemorrhage and ischaemia occurred in 25 (1·45%) and 67 participants (3·90%) in occasional users and 69 (4·01%) and 100 participants (5·81%) in regular users, whereas cancer occurred in 32 participants (1·86%) in occasional users and 26 participants (1·51%) in regular users. The crude and adjusted net clinical risks of low-dose aspirin use between the two frequency of users (≥ 80% vs. prevention against major vascular diseases and cancer. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  3. Respiratory drugs prescribed off-label among children in the outpatient clinics of a hospital in Malaysia.

    Science.gov (United States)

    Mohamad, Nurul Fadilah; Mhd Ali, Adliah; Mohamed Shah, Noraida

    2015-02-01

    Prescribing medicines in an unlicensed and off-label manner for children is a widespread practice around the world. To determine the extent and predictors of off-label respiratory drug prescriptions for children in the outpatient clinics of a hospital in Malaysia. Outpatient clinics at the Universiti Kebangsaan Malaysia Medical Centre, a tertiary teaching hospital in Malaysia. The pharmacy-based computer system and medical records of the patients were utilized to collect data from 220 pediatric patients who were prescribed at least one respiratory drug from July 2011 to December 2011. Characteristics of the off-label respiratory drug prescriptions were measured. A total of 134 children (60.9 %) received at least one respiratory drug prescribed in an off-label manner. The most common reasons for the off-label prescribing of drugs were off-label use by indication (31.5 %), followed by higher than the recommended dose (24.9 %) and lower than the recommended frequency (17.1 %). Diphenhydramine was the most common respiratory drug prescribed off-label. The number of medications prescribed was the only significant predictor of off-label prescription of respiratory drugs. Pediatric patients receiving 4-6 medications were 7.8 times more likely to receive at least one off-label respiratory drug compared to pediatric patients that received 1-3 medications (OR 7.8, 95 % CI 1.74-37.44). There was substantial prescribing of respiratory drugs for children in an off-label manner at the outpatient clinics at the Universiti Kebangsaan Malaysia Medical Centre. This highlights the need for more research to be carried out on respiratory drugs in the pediatric population.

  4. Impact of multiple-dose versus single-dose inhaler devices on COPD patients’ persistence with long-acting β2-agonists: a dispensing database analysis

    Science.gov (United States)

    van Boven, Job FM; van Raaij, Joost J; van der Galiën, Ruben; Postma, Maarten J; van der Molen, Thys; Dekhuijzen, PN Richard; Vegter, Stefan

    2014-01-01

    Background: With a growing availability of different devices and types of medication, additional evidence is required to assist clinicians in prescribing the optimal medication in relation to chronic obstructive pulmonary disease (COPD) patients’ persistence with long-acting β2-agonists (LABAs). Aims: To assess the impact of the type of inhaler device (multiple-dose versus single-dose inhalers) on 1-year persistence and switching patterns with LABAs. Methods: A retrospective observational cohort study was performed comparing a cohort of patients initiating multiple-dose inhalers and a cohort initiating single-dose inhalers. The study population consisted of long-acting bronchodilator naive COPD patients, initiating inhalation therapy with mono-LABAs (formoterol, indacaterol or salmeterol). Analyses were performed using pharmacy dispensing data from 1994 to 2012, obtained from the IADB.nl database. Study outcomes were 1-year persistence and switching patterns. Results were adjusted for initial prescriber, initial medication, dosing regimen and relevant comorbidities. Results: In all, 575 patients initiating LABAs were included in the final study cohort. Among them, 475 (83%) initiated a multiple-dose inhaler and 100 (17%) a single-dose inhaler. Further, 269 (47%) initiated formoterol, 9 (2%) indacaterol and 297 (52%) salmeterol. There was no significant difference in persistence between users of multiple-dose or single-dose inhalers (hazard ratio: 0.98, 95% confidence interval: 0.76–1.26, P=0.99). Over 80% re-started or switched medication. Conclusions: There seems no impact of inhaler device (multiple-dose versus single-dose inhalers) on COPD patients’ persistence with LABAs. Over 80% of patients who initially seemed to discontinue LABAs, re-started their initial medication or switched inhalers or medication within 1 year. PMID:25274453

  5. Optimized dose conformation of multi-leaf collimator fields

    International Nuclear Information System (INIS)

    Serago, Christopher F.; Buskirk, Steven J.; Foo, May L.; McLaughlin, Mark P.

    1996-01-01

    Purpose/Objective: Current commercially available multi-leaf collimators (MLC) have leaf widths of about 1 cm. These leaf widths may produce stepped dose gradients at the fields edges at the 50% dose level. Small local perturbations of the dose distribution from the prescribed/expected dose distribution may not be acceptable for some clinical applications. Improvements to the conformation of the MLC dose distribution may be achieved using multiple exposures per MLC field, with either shifting the table/patient position, or rotating the orientation of the MLC jaws between exposures. Material and Methods: Dose distributions for MLC, primary jaws only, and lead alloy block fields were measured with film dosimetry for 6 and 20 MV photon beams in a solid water phantom. Square, circular, and typical clinical prostate, brain, lung, esophagus, and head and neck fields were measured. MLC field shapes were produced using a commercial MLC with a leaf width of 1 cm at the treatment isocenter. The dose per MLC field was delivered in either single (conventional) or multiple exposures. The table(patient) position or the collimator rotation was shifted between exposures when multiple exposure MLC fields were used. Differences in the dose distribution were evaluated at the 90% and 50% isodose level. Displacements of the measured 50% isodose from the prescribed/expected 50% isodose were measured at 5 degree intervals. Results: Measurements of the penumbra at a 10 cm depth for square fields show that using double exposure MLC fields with .5 cm table index decreases the effective penumbra by 1 mm. For clinical shaped fields, displacements between the prescribed/expected 50% isodose and the measured 50% isodose for conventional single exposure MLC fields are measured to be as great as 9 mm, and discrepancies on the order of 5 to 6 mm are common. In contrast, the maximum displacement errors measured with multiple exposure MLC fields are less than 5 mm and rarely more than 4 mm. In some

  6. Radiation dose reduction in pediatric CT

    International Nuclear Information System (INIS)

    Robinson, A.E.; Hill, E.P.; Harpen, M.D.

    1986-01-01

    The relationship between image noise and radiation dose was investigated in computed tomography (CT) images of a pediatric abdomen phantom. A protocol which provided a minimum absorbed dose consistent with acceptable image noise criteria was determined for a fourth generation CT scanner. It was found that pediatric abdominal CT scans could maintain diagnostic quality with at least a 50% reduction in dose from the manufacturers' suggested protocol. (orig.)

  7. Strategies for Online Organ Motion Correction for Intensity-Modulated Radiotherapy of Prostate Cancer: Prostate, Rectum, and Bladder Dose Effects

    International Nuclear Information System (INIS)

    Rijkhorst, Erik-Jan; Lakeman, Annemarie; Nijkamp, Jasper; Bois, Josien de; Herk, Marcel van; Lebesque, Joos V.; Sonke, Jan-Jakob

    2009-01-01

    Purpose: To quantify and evaluate the accumulated prostate, rectum, and bladder dose for several strategies including rotational organ motion correction for intensity-modulated radiotherapy (IMRT) of prostate cancer using realistic organ motion data. Methods and Materials: Repeat computed tomography (CT) scans of 19 prostate patients were used. Per patient, two IMRT plans with different uniform margins were created. To quantify prostate and seminal vesicle motion, repeat CT clinical target volumes (CTVs) were matched onto the planning CTV using deformable registration. Four different strategies, from online setup to full motion correction, were simulated. Rotations were corrected for using gantry and collimator angle adjustments. Prostate, rectum, and bladder doses were accumulated for each patient, plan, and strategy. Minimum CTV dose (D min ), rectum equivalent uniform dose (EUD, n = 0.13), and bladder surface receiving ≥78 Gy (S78), were calculated. Results: With online CTV translation correction, a 7-mm margin was sufficient (i.e., D min ≥ 95% of the prescribed dose for all patients). A 4-mm margin required additional rotational correction. Margin reduction lowered the rectum EUD(n = 0.13) by ∼2.6 Gy, and the bladder S78 by ∼1.9%. Conclusions: With online correction of both translations and rotations, a 4-mm margin was sufficient for 15 of 19 patients, whereas the remaining four patients had an underdosed CTV volume <1%. Margin reduction combined with online corrections resulted in a similar or lower dose to the rectum and bladder. The more advanced the correction strategy, the better the planned and accumulated dose agreed.

  8. Antimalarial prescribing patterns in state hospitals and selected ...

    African Journals Online (AJOL)

    slowdown of progression to resistance could be achieved by improving prescribing practice, drug quality, and patient compliance. Objective: To determine the antimalarial prescribing pattern and to assess rational prescribing of chloroquine by prescribers in government hospitals and parastatals in Lagos State. Methods: ...

  9. Introduction to prescribed fires in Southern ecosystems

    Science.gov (United States)

    Thomas A. Waldrop; Scott L. Goodrick

    2012-01-01

    This publication is a guide for resource managers on planning and executing prescribed burns in Southern forests and grasslands. It includes explanations of reasons for prescribed burning, environmental effects, weather, and techniques as well as general information on prescribed burning.

  10. Dose mapping role in gamma irradiation industry

    International Nuclear Information System (INIS)

    Noriah Mod Ali; John Konsoh Sangau; Mazni Abd Latif

    2002-01-01

    In this studies, the role of dosimetry activity in gamma irradiator was discussed. Dose distribution in the irradiator, which is a main needs in irradiator or chamber commissioning. This distribution data were used to confirm the dosimetry parameters i.e. exposure time, maximum and minimum dose map/points, and dose distribution - in which were used as guidelines for optimum product irradiation. (Author)

  11. A Computer Prescribing Order Entry-Clinical Decision Support system designed for neonatal care: results of the 'preselected prescription' concept at the bedside.

    Science.gov (United States)

    Gouyon, B; Iacobelli, S; Saliba, E; Quantin, C; Pignolet, A; Jacqz-Aigrain, E; Gouyon, J B

    2017-02-01

    The neonatal intensive care units (NICUs) are at the highest risk of drug dose error of all hospital wards. NICUs also have the most complicated prescription modalities. The computerization of the prescription process is currently recommended to decrease the risk of preventable adverse drug effects (pADEs) in NICUs. However, Computer Prescribing Order Entry-Clinical Decision Support (C.P.O.E./C.D.S.) systems have been poorly studied in NICUs, and their technical compatibility with neonatal specificities has been limited. We set up a performance study of the preselected prescription of drugs for neonates, which limited the role of the prescriber to choosing the drugs and their indications. A single 29 bed neonatal ward used this neonatal C.P.O.E./C.D.S. system for all prescriptions of all hospitalized newborns over an 18-month period. The preselected prescription of drugs was based on the indication, gestational age, body weight and post-natal age. The therapeutic protocols were provided by a formulary reference (330 drugs) that had been specifically designed for newborns. The preselected prescription also gave complete information about preparation and administration of drugs by nurses. The prescriber was allowed to modify the preselected prescription but alarms provided warning when the prescription was outside the recommended range. The main clinical characteristics and all items of each line of prescription were stored in a data warehouse, thus enabling this study to take place. Seven hundred and sixty successive newborns (from 24 to 42 weeks' gestation) were prescribed 52 392 lines of prescription corresponding to 65 drugs; About 30·4% of neonates had at least one out of licensed prescription; A prescription out of the recommended range for daily dose was recorded for 1·0% of all drug prescriptions. WHAT IS NEW?: The C.P.O.E./C.D.S. systems can currently provide a complete preselected prescription in NICUs according to dose rules, which are specific to

  12. 69-74 A Retrospective Analysis of Prescribing Prac

    African Journals Online (AJOL)

    user

    A Retrospective Analysis of Prescribing Practice Based on WHO Prescribing Indicators at Four. Selected Hospitals of West ... Key words: World Health Organization, prescribing indicators, rational drug use. INTRODUCTION. Indicators of ... factors, the risk of irrational prescribing could raise several folds. Irrational use of ...

  13. What drives the prescribing of growth hormone preparations in England? Prices versus patient preferences.

    Science.gov (United States)

    Chapman, Stephen R; Fitzpatrick, Raymond W; Aladul, Mohammed I

    2017-04-11

    The patent expiry of a number of biological medicines and the advent of biosimilars raised the expectations of healthcare commissioners that biosimilars would reduce the high cost of these medicines and produce potential savings to the NHS. We aimed to examine the prescribing pattern of different growth hormone preparations (ready to use and reconstitution requiring) in primary and secondary care in England to determine relative rates of decrease or increase and identify the possible factors influencing prescribing following the introduction of biosimilar growth hormone in 2008. Longitudinal observational study. Primary care prescribing cost and volume data was derived from the NHS business services authority website, and for secondary care from the DEFINE database, between April 2011 and December 2015. Quarterly prescribing analysis to examine trends and measure the relationship between usage and price. Expenditure and usage of growth hormone in primary care decreased by 17.91% and 7.29%, respectively, whereas expenditure and usage in secondary care increased by 68.41% and 100%, respectively, between April 2011 and December 2015. The usage of reconstitution requiring products significantly declined in primary care (R²=0.9292) and slightly increased in use in secondary care (R²=0.139). In contrast, the usage of ready-to-use products significantly increased in use in primary (R²=0.7526) and secondary care (R²=0.9633), respectively. Weak or no correlation existed between the usage and price of growth hormone preparations in primary and secondary care. The price of growth hormone products was not the key factor influencing the prescribing of the biological medicines. The main driver for specific product selection was the ease of use and the number of steps in dose preparation. Prescribers appear to be taking into account patient preferences rather than cost in their prescribing decisions. Published by the BMJ Publishing Group Limited. For permission to use (where

  14. A dose-volume comparison of prostate cancer (PC) radiotherapy (RT) techniques for penile-structures (PNS) - a neglected critical organ in PC RT

    International Nuclear Information System (INIS)

    Dabrowski, Jolanta; Myrianthopoulos, Leon; Nguyen, Ai; Chen, George; Vijayakumar, Srinivasan

    1996-01-01

    Purpose/Objective: Three-dimensional conformal RT(3DCRT) is revolutionizing the use of RT in PC. Rectum and bladder, and in some studies femoral heads are included as critical structures (CS) in comparing rival plans in 3DCRT. Although RT-induced impotence is a major complication of conventional RT, with 30-50% incidence, to date no study has included PNS as a CS. This study is an attempt to remedy this deficiency in the 3DCRT planning in PC. Materials and Methods: After immobilization with Aquaplast, computed-tomography (CT) scans were obtained in supine treatment position from top of lumbar-3 vertebra to lesser-trochanter of the femora with 5-8mm slice-thicknesses; IV contrast was used in all patients. Prostate, seminal vesicles (GTV), and CSs were outlined, including PNS. Corpora cavernosa and bulbous spongiosum together were identified as PNS. Appropriate margins for CTV and PTV were used; total margin to the block from GTV was 2cm. Tumor-minimum doses were prescribed to the 100% isodose line. Dose-volume histograms (DVHs) were obtained to compare three different techniques: 1. Conventional 4 field box technique (4FC) with equal weighting; 2. Six field (2 laterals and 4 obliques [45 degrees from midline] (6FO), with 50% dose delivery from the laterals; and 3. Four equally weighted, non-axial fields [2 laterals and 2 inferior anterior obliques at 45 degree couch and gantry rotations] (4FN). Results: A total of 12 patients are included in the study. The mean and range of percentage volume of PNS receiving more than 30, 60, and 90% of the prescribed dose are shown in the table below: Box plots, such as the example shown above, were used to compare techniques overall. The 6-field coplanar technique treated the least PNS volume beyond a given dose, followed by 4FC and 4FN techniques. The order of least to maximum percent of PNS treated in most individual patients also followed the same trend. In the majority, 6FO and 4FN delivered relatively comparable doses to

  15. Prescribing Antibiotics

    DEFF Research Database (Denmark)

    Pedersen, Inge Kryger; Jepsen, Kim Sune

    2018-01-01

    The medical professions will lose an indispensable tool in clinical practice if even simple infections cannot be cured because antibiotics have lost effectiveness. This article presents results from an exploratory enquiry into “good doctoring” in the case of antibiotic prescribing at a time when...... the knowledge base in the healthcare field is shifting. Drawing on in-depth interviews about diagnosing and prescribing, the article demonstrates how the problem of antimicrobial resistance is understood and engaged with by Danish general practitioners. When general practitioners speak of managing “non......-medical issues,” they refer to routines, clinical expertise, experiences with their patients, and decision-making based more on contextual circumstances than molecular conditions—and on the fact that such conditions can be hard to assess. This article’s contribution to knowledge about how new and global health...

  16. Specification of volume and dose in radiotherapy

    International Nuclear Information System (INIS)

    Levernes, S.

    1997-01-01

    As a result of a questionnaire about dose and volume specifications in radiotherapy in the Nordic countries, a group has been set up to propose common recommendations for these countries. The proposal is partly based on ICRU 50, but with major extensions. These extensions fall into three areas: patient geometry, treatment geometry, and dose specifications. For patient geometry and set-up one need alignment markings and anatomical reference points, the latter can be divided into internal and external reference points. These points are necessary to get relationships between coordinate systems related to patient and to treatment unit. For treatment geometry the main volume will be an anatomical target volume which just encompass the clinical target volume with all its variations and movements. This anatomical volume are the most suitable volume for prescription, optimization and reporting dose. A set-up margin should be added to the beam periphery in beams-eye-view to get the minimum size and shape of the beam. For dose specification the most important parameter for homogeneous dose distributions is the arithmetic mean of dose to the anatomical target volume together with its standard deviation. In addition the dose to the ICRU reference point should be reported for intercomparison, together with minimum and maximum doses or dose volume histograms for the anatomical target volume. (author)

  17. Treatment dose-response in amblyopia therapy: the Monitored Occlusion Treatment of Amblyopia Study (MOTAS).

    Science.gov (United States)

    Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2004-09-01

    Amblyopia is the commonest visual disorder of childhood. Yet the contributions of the two principal treatments (spectacle wear and occlusion) to outcome are unknown. This study was undertaken to investigate the dose-response relationship of amblyopia therapy. The study comprised three distinct phases: baseline, in which repeat measures of visual function were undertaken to confirm the initial visual deficit; refractive adaptation: an 18-week period of spectacle wear with six weekly measurements of logarithm of the minimum angle of resolution (logMAR) visual acuity; occlusion: in which participants were prescribed 6 hours of "patching" per day. In the latter phase, occlusion was objectively monitored and logMAR visual acuity recorded at 2-week intervals until any observed gains had ceased. Data were obtained from 94 participants (mean age, 5.1 +/- 1.4 years) with amblyopia associated with strabismus (n = 34), anisometropia (n = 23), and both anisometropia and strabismus (n = 37). Eighty-six underwent refractive adaptation. Average concordance with patching was 48%. The relationship between logMAR visual acuity gain and total occlusion dose was monotonic and linear. Increasing dose rate beyond 2 h/d hastened the response but did not improve outcome. More than 80% of the improvement during occlusion occurred within 6 weeks. Treatment outcome was significantly better for children younger than 4 years (n = 17) than in those older than 6 years (n = 24; P = 0.0014). Continuous objective monitoring of the amount of patching therapy received has provided insight into the dose-response relationship of occlusion therapy for amblyopia. Patching is most effective within the first few weeks of treatment, even for those in receipt of a relatively small dose. Further studies are needed to elucidate the neural basis for the dose-response functions. Copyright Association for Research in Vision and Ophthalmology

  18. A possible method using baseline hormonal levels to prescribe the appropriate oral therapeutic radioiodine dosage for Graves' disease

    International Nuclear Information System (INIS)

    Nakajo, Masayuki; Tsuchimochi, Shinsaku; Jinguji, Megumi; Tanabe, Hiroaki; Umanodan, Tomoichi; Nakabeppu, Yoshiaki

    2007-01-01

    The purpose of this study was to retrospectively examine the correlations of hormonal ratios with radioiodine I-131 therapeutic parameters and the potentiality of prescribing the therapeutic I-131 target dosage for an individual patient with Graves' disease using baseline serum levels of thyroid hormones. Serum T3, T4, and FT4 levels 6 and 12 months after I-131 therapy/baseline levels (hormonal ratios) were calculated for a total of 68 therapeutic courses in 57 patients with Graves' disease. The therapeutic parameters were absorbed dose (Gy), dose concentration (μCi/g) and oral dose (mCi). Linear regression analysis was performed for correlating hormonal ratios (X) and therapeutic parameters (Y). Significant (P<0.05) negative correlations of the hormonal ratios were observed with absorbed dose (R -0.50 for T3, -0.61 for T4, and -0.46 for FT4 at 6 months, and -0.29 for T3, -0.44 for T4 at 12 months) and dose concentration (R -0.57 for T3, -0.58 for T4, and -0.49 for FT4 at 6 months and -0.27 for T3, -0.27 for T4 at 12 months), but not with oral dose at 6 months and 12 months or the absorbed dose and dose concentration for FT4 at 12 months. The correlations were higher at 6 months than at 12 months and in serum T4 than in serum T3 and FT4. The formulae for serum T4 at 6 months were as follows: Y (Gy)=109-53X and Y (μCi/g)=109-52X. These results suggest that the hormonal ratios are significantly correlated with the absorbed dose and dose concentration. The formulae for serum T4 at 6 months may serve to prescribe the individual oral dosage for Graves' disease, although the correlation coefficients are about -0.6. (author)

  19. Dose error analysis for a scanned proton beam delivery system

    International Nuclear Information System (INIS)

    Coutrakon, G; Wang, N; Miller, D W; Yang, Y

    2010-01-01

    All particle beam scanning systems are subject to dose delivery errors due to errors in position, energy and intensity of the delivered beam. In addition, finite scan speeds, beam spill non-uniformities, and delays in detector, detector electronics and magnet responses will all contribute errors in delivery. In this paper, we present dose errors for an 8 x 10 x 8 cm 3 target of uniform water equivalent density with 8 cm spread out Bragg peak and a prescribed dose of 2 Gy. Lower doses are also analyzed and presented later in the paper. Beam energy errors and errors due to limitations of scanning system hardware have been included in the analysis. By using Gaussian shaped pencil beams derived from measurements in the research room of the James M Slater Proton Treatment and Research Center at Loma Linda, CA and executing treatment simulations multiple times, statistical dose errors have been calculated in each 2.5 mm cubic voxel in the target. These errors were calculated by delivering multiple treatments to the same volume and calculating the rms variation in delivered dose at each voxel in the target. The variations in dose were the result of random beam delivery errors such as proton energy, spot position and intensity fluctuations. The results show that with reasonable assumptions of random beam delivery errors, the spot scanning technique yielded an rms dose error in each voxel less than 2% or 3% of the 2 Gy prescribed dose. These calculated errors are within acceptable clinical limits for radiation therapy.

  20. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  1. Medicare Provider Data - Part D Prescriber

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Part D Prescriber Public Use File (PUF) provides information on prescription drugs prescribed by individual physicians and other health care providers and paid...

  2. The quality of outpatient antimicrobial prescribing

    DEFF Research Database (Denmark)

    Malo, Sara; Bjerrum, Lars; Feja, Cristina

    2013-01-01

    The aim of the study was to analyse and compare the quality of outpatient antimicrobial prescribing in Denmark and Aragón (in northeastern Spain), with the objective of assessing inappropriate prescribing....

  3. Medication prescribing errors in the medical intensive care unit of Tikur Anbessa Specialized Hospital, Addis Ababa, Ethiopia.

    Science.gov (United States)

    Sada, Oumer; Melkie, Addisu; Shibeshi, Workineh

    2015-09-16

    Medication errors (MEs) are important problems in all hospitalized populations, especially in intensive care unit (ICU). Little is known about the prevalence of medication prescribing errors in the ICU of hospitals in Ethiopia. The aim of this study was to assess medication prescribing errors in the ICU of Tikur Anbessa Specialized Hospital using retrospective cross-sectional analysis of patient cards and medication charts. About 220 patient charts were reviewed with a total of 1311 patient-days, and 882 prescription episodes. 359 MEs were detected; with prevalence of 40 per 100 orders. Common prescribing errors were omission errors 154 (42.89%), 101 (28.13%) wrong combination, 48 (13.37%) wrong abbreviation, 30 (8.36%) wrong dose, wrong frequency 18 (5.01%) and wrong indications 8 (2.23%). The present study shows that medication errors are common in medical ICU of Tikur Anbessa Specialized Hospital. These results suggest future targets of prevention strategies to reduce the rate of medication error.

  4. Dose prescription complexity versus tumor control probability in biologically conformal radiotherapy

    International Nuclear Information System (INIS)

    South, C. P.; Evans, P. M.; Partridge, M.

    2009-01-01

    The technical feasibility and potential benefits of voxel-based nonuniform dose prescriptions for biologically heterogeneous tumors have been widely demonstrated. In some cases, an ''ideal'' dose prescription has been generated by individualizing the dose to every voxel within the target, but often this voxel-based prescription has been discretized into a small number of compartments. The number of dose levels utilized and the methods used for prescribing doses and assigning tumor voxels to different dose compartments have varied significantly. The authors present an investigation into the relationship between the complexity of the dose prescription and the tumor control probability (TCP) for a number of these methods. The linear quadratic model of cell killing was used in conjunction with a number of modeled tumors heterogeneous in clonogen density, oxygenation, or proliferation. Models based on simple mathematical functions, published biological data, and biological image data were investigated. Target voxels were assigned to dose compartments using (i) simple rules based on the initial biological distribution, (ii) iterative methods designed to maximize the achievable TCP, or (iii) methods based on an ideal dose prescription. The relative performance of the simple rules was found to depend on the form of heterogeneity of the tumor, while the iterative and ideal dose methods performed comparably for all models investigated. In all cases the maximum achievable TCP was approached within the first few (typically two to five) compartments. Results suggest that irrespective of the pattern of heterogeneity, the optimal dose prescription can be well approximated using only a few dose levels but only if both the compartment boundaries and prescribed dose levels are well chosen.

  5. SU-E-T-381: Evaluation of Calculated Dose Accuracy for Organs-At-Risk Located at Out-Of-Field in a Commercial Treatment Planning System for High Energy Photon Beams Produced From TrueBeam Accelerators

    International Nuclear Information System (INIS)

    Wang, L; Ding, G

    2015-01-01

    Purpose: Dose calculation accuracy for the out-of-field dose is important for predicting the dose to the organs-at-risk when they are located outside primary beams. The investigations on evaluating the calculation accuracy of treatment planning systems (TPS) on out-of-field dose in existing publications have focused on low energy (6MV) photon. This study evaluates out-of-field dose calculation accuracy of AAA algorithm for 15MV high energy photon beams. Methods: We used the EGSnrc Monte Carlo (MC) codes to evaluate the AAA algorithm in Varian Eclipse TPS (v.11). The incident beams start with validated Varian phase-space sources for a TrueBeam linac equipped with Millennium 120 MLC. Dose comparisons between using AAA and MC for CT based realistic patient treatment plans using VMAT techniques for prostate and lung were performed and uncertainties of organ dose predicted by AAA at out-of-field location were evaluated. Results: The results show that AAA calculations under-estimate doses at the dose level of 1% (or less) of prescribed dose for CT based patient treatment plans using VMAT techniques. In regions where dose is only 1% of prescribed dose, although AAA under-estimates the out-of-field dose by 30% relative to the local dose, it is only about 0.3% of prescribed dose. For example, the uncertainties of calculated organ dose to liver or kidney that is located out-of-field is <0.3% of prescribed dose. Conclusion: For 15MV high energy photon beams, very good agreements (<1%) in calculating dose distributions were obtained between AAA and MC. The uncertainty of out-of-field dose calculations predicted by the AAA algorithm for realistic patient VMAT plans is <0.3% of prescribed dose in regions where the dose relative to the prescribed dose is <1%, although the uncertainties can be much larger relative to local doses. For organs-at-risk located at out-of-field, the error of dose predicted by Eclipse using AAA is negligible. This work was conducted in part using the

  6. Impact of pharmacists assisting with prescribing and undertaking medication review on oxycodone prescribing and supply for patients discharged from surgical wards.

    Science.gov (United States)

    Tran, T; Taylor, S E; Hardidge, A; Findakly, D; Aminian, P; Elliott, R A

    2017-10-01

    Overprescribing of oxycodone is a contributor to the epidemic of prescription opioid misuse and deaths. Practice models to optimize oxycodone prescribing and supply need to be evaluated. We explored the impact of pharmacist-assisted discharge prescribing and medication review on oxycodone prescribing and supply for patients discharged from surgical wards. A retrospective audit was conducted on two surgical inpatient wards following a 16-week prospective pre- and post-intervention study. During the pre-intervention period, discharge prescriptions were prepared by hospital doctors and then reviewed by a ward pharmacist (WP) before being dispensed. Post-intervention, prescriptions were prepared by a project pharmacist in consultation with hospital doctors and then reviewed by a WP and dispensed. Proportion of patients who were prescribed, and proportion supplied, oxycodone on discharge; Median amount (milligrams) of oxycodone prescribed and supplied, for patients who were prescribed and supplied at least one oxycodone-containing preparation, respectively. A total of 320 and 341 patients were evaluated pre- and post-intervention, respectively. Pre-intervention, 75.6% of patients were prescribed oxycodone; after WP review, 60.3% were supplied oxycodone (Psupplied was 100 milligrams/patient. Post-intervention, 68.6% of patients were prescribed oxycodone; after WP review, 57.8% were supplied oxycodone (Psupplied was 50 milligrams/patient (difference in amount prescribed and supplied: 50 milligrams, Psupplied oxycodone but not the amount supplied/patient. Having a pharmacist assist with prescribing reduced the amount of oxycodone supplied. © 2017 John Wiley & Sons Ltd.

  7. Improvement of dose distribution of esophageal irradiation using the field-within-a-field technique

    International Nuclear Information System (INIS)

    Iwai, Tsugunori; Okabe, Keigo; Yamato, Hidetada; Murakami, Jyunji; Nakazawa, Yasuo; Kato, Mitsuyoshi

    2002-01-01

    The wide radiation field for mediastinal dose distribution should be inhomogeneous with the usual simple opposed beam irradiation. The purpose of this study was to improve the dose distribution of the mediastinum using a conventional planning system with a dose-volume histogram (DVH) and the field-in-field technique. Three-dimensional (3D) dose distribution is obtained in bilateral opposed-field irradiation. An overdose area obtained from the 3D dose distribution is defined and reprojected into the irradiation field. A new reduced field is created by removing the reprojected overdose area. A 3D dose distribution is again obtained and compared with the results from first one. Procedures were repeated until each of the target volumes was within ±5% of the prescribed dose and the irradiation volume within 107% or less of the prescribed dose. From the DVH analysis, our field-within-a-field technique resulted in a more uniform dose distribution within the conventional planning. The field-within-a-field technique involves many parameters, and an inverse planning algorithm is suitable for computation. However, with our method, the forward planning system is adequate for planning, at least in a relatively straightforward planning system such as bilateral opposed fields therapy. (author)

  8. Inhaled Drug Delivery: A Practical Guide to Prescribing Inhaler Devices

    Directory of Open Access Journals (Sweden)

    Pierre Ernst

    1998-01-01

    Full Text Available Direct delivery of medication to the target organ results in a high ratio of local to systemic bioavailability and has made aerosol delivery of respiratory medication the route of choice for the treatment of obstructive lung diseases. The most commonly prescribed device is the pressurized metered dose inhaler (pMDI; its major drawback is the requirement that inspiration and actuation of the device be well coordinated. Other requirements for effective drug delivery include an optimal inspiratory flow, a full inspiration from functional residual capacity and a breath hold of at least 6 s. Available pMDIs are to be gradually phased out due to their use of atmospheric ozone-depleting chlorofluorocarbons (CFCs as propellants. Newer pMDI devices using non-CFC propellants are available; preliminary experience suggests these devices greatly increase systemic bioavailability of inhaled corticosteroids. The newer multidose dry powder inhalation devices (DPIs are breath actuated, thus facilitating coordination with inspiration, and contain fewer ingredients. Furthermore, drug delivery is adequate even at low inspired flows, making their use appropriate in almost all situations. Equivalence of dosing among different devices for inhaled corticosteroids will remain imprecise, requiring the physician to adjust the dose of medication to the lowest dose that provides adequate control of asthma. Asthma education will be needed to instruct patients on the effective use of the numerous inhalation devices available.

  9. Prescribing methadone for pain management in end-of-life care.

    Science.gov (United States)

    Manfredonia, John F

    2005-03-01

    Methadone hydrochloride is an effective, inexpensive, and relatively safe opioid to use in the treatment of patients with chronic pain. It is especially effective in management of pain during the final stages of life, as it is the only long-acting analgesic available in liquid form. However, because methadone has a long half-life, individual wide variations, and potential for accumulation and overdosage, physicians must judiciously and conscientiously prescribe it. Also, they should closely monitor patients during the titration phase and educate them with regard to basic pharmacologic properties and potential side effects. A plan to start at low doses and proceed slowly is applicable to methadone.

  10. Psychologists' right to prescribe – should prescribing privileges be ...

    African Journals Online (AJOL)

    Current changes in legislation regarding prescription rights increase the possibility of non-medical practitioners being authorised to presctibe medication. There has been ongoing debate about granting psychologists in South Africa a limited right to prescribe (RTP) psychotropic medication. The main reasons advanced for ...

  11. Evaluation of a diabetes nurse specialist prescribing project.

    Science.gov (United States)

    Wilkinson, Jill; Carryer, Jenny; Adams, Jeffery

    2014-08-01

    To evaluate the diabetes nurse specialist prescribing project with the aim of determining whether diabetes nurse specialist prescribing is safe and effective and to inform the implementation and extension of registered nurse prescribing. Registered nurses in many countries are able to prescribe medicines, but in New Zealand, prior to the diabetes nurse specialist project, nurse practitioners were the only nurses who could prescribe medicines. New regulations allowed the nurses to prescribe a limited number of prescription medicines. The study was a process and outcome clinical programme evaluation. The project took place between April-September 2011 and involved 12 diabetes nurse specialist in four localities. Quantitative data were collected from clinical records maintained by the diabetes nurse specialist for the project (1274 patients and 3402 prescribing events), from surveys with stakeholders (general practitioners, n = 30; team members, n = 19; and patients, n = 89) and audits from patient notes (n = 117) and prescriptions (n = 227), and qualitative data from interviews with project participants (n = 18) and patients (n = 19). All data were analysed descriptively. Diabetes nurse specialist prescribing was determined to be safe, of high quality and appropriate. It brought important benefits to the effectiveness of specialist diabetes services, was acceptable to patients and was supported by the wider healthcare team. These findings are consistent with the findings reported in the international literature about nurse prescribing in a range of different practice areas. Clarification of the education and competence requirements and resourcing for the ongoing supervision of nurses is recommended if the prescribing model is to be extended. Diabetes nurse specialist prescribing improved access to medicines by providing a more timely service. Nurses felt more satisfied with their work because they could independently provide a complete episode of care

  12. Influences on the prescribing of new drugs.

    Science.gov (United States)

    Tobin, Luke; de Almedia Neto, Abelio C; Wutzke, Sonia; Patterson, Craig; Mackson, Judith; Weekes, Lynn; Williamson, Margaret

    2008-01-01

    The aim of this study was to identify the factors that influence prescribing of new drugs among general practitioners, endocrinologists and psychiatrists. Four focus groups were conducted with GPs, endocrinologists and psychiatrists on sources of awareness and influences on prescribing of new drugs. Pharmaceutical companies were the most important source for becoming aware of new drugs. There were many influences on the decision to prescribe a new drug, the most important being efficacy, safety, cost and advantage over existing therapies. Endocrinologists placed greater emphasis on evidence from clinical trials and scientific conferences, and psychiatrists and GPs placed more weight on pharmaceutical representatives, colleagues and specialists. New drug prescribing occurs in a complex environment with many influences. Effective interventions to promote rational, safe and effective prescribing of new drugs will need to be cognisant of these factors.

  13. Antibiotic prescribing in dental practice in Belgium.

    Science.gov (United States)

    Mainjot, A; D'Hoore, W; Vanheusden, A; Van Nieuwenhuysen, J-P

    2009-12-01

    To assess the types and frequency of antibiotic prescriptions by Belgian dentists, the indications for antibiotic prescription, and dentists' knowledge about recommended practice in antibiotic use. In this cross-sectional survey, dental practitioners were asked to record information about all antibiotics prescribed to their patients during a 2-week period. The dental practitioners were also asked to complete a self-administered questionnaire regarding demographic data, prescribing practices, and knowledge about antibiotic use. A random sample of 268 Belgian dentists participated in the survey. During the 2-week period, 24 421 patient encounters were recorded; 1033 patients were prescribed an antibiotic (4.2%). The median number of prescriptions per dentist for the 2 weeks was 3. Broad spectrum antibiotics were most commonly prescribed: 82% of all prescriptions were for amoxycillin, amoxycillin-clavulanic acid and clindamycin. Antibiotics were often prescribed in the absence of fever (92.2%) and without any local treatment (54.2%). The most frequent diagnosis for which antibiotics were prescribed was periapical abscess (51.9%). Antibiotics were prescribed to 63.3% of patients with periapical abscess and 4.3% of patients with pulpitis. Patterns of prescriptions were confirmed by the data from the self-reported practice. Discrepancies between observed and recommended practice support the need for educational initiatives to promote rational use of antibiotics in dentistry in Belgium.

  14. A study of antibiotic prescribing

    DEFF Research Database (Denmark)

    Jaruseviciene, L.; Radzeviciene-Jurgute, R.; Jurgutis, A.

    2012-01-01

    Background. Globally, general practitioners (GPs) write more than 90% of all antibiotic prescriptions. This study examines the experiences of Lithuanian and Russian GPs in antibiotic prescription for upper respiratory tract infections, including their perceptions of when it is not indicated...... clinically or pharmacologically. Methods. 22 Lithuanian and 29 Russian GPs participated in five focus group discussions. Thematic analysis was used to analyse the data. Results. We identified four main thematic categories: patients' faith in antibiotics as medication for upper respiratory tract infections......; patient potential to influence a GP's decision to prescribe antibiotics for upper respiratory tract infections; impediments perceived by GPs in advocating clinically grounded antibiotic prescribing with their patients, and strategies applied in physician-patient negotiation about antibiotic prescribing...

  15. Prescribing procrastination

    Science.gov (United States)

    Thomson, George H.

    1979-01-01

    In his everyday work the family physician sees many patients whose problems have been diagnosed but for whom postponement of an active treatment plan is indicated. The physician must therefore prescribe procrastination in a carefully planned way. I describe some ideas and practical methods for doing this. PMID:529244

  16. Antibiotic prescribing and patient satisfaction in primary care in England: cross-sectional analysis of national patient survey data and prescribing data.

    Science.gov (United States)

    Ashworth, Mark; White, Patrick; Jongsma, Hannah; Schofield, Peter; Armstrong, David

    2016-01-01

    Concerns about adverse effects on patient satisfaction may be an important obstacle to attempts to curtail antibiotic prescribing. To determine the relationship between antibiotic prescribing in general practice and reported patient satisfaction. Retrospective cross-sectional study of general practices in England. Data were obtained from the General Practice Patient Survey (GPPS) in 2012 (2.7 million questionnaires in England; 982 999 responses; response rate 36%); the national Quality and Outcomes Framework dataset for England, 2011-2012 (8164 general practices); and general practice and demographic characteristics. Standardised measures of antibiotic prescribing volumes were obtained for each practice in England during 2012-2013, together with 12 other nationally available prescribing variables. The role of antibiotic prescribing volume was identified as a determinant of GPPS scores and adjusted for demographic and practice factors using multiple linear regression. The final dataset consisted of 7800 (95.5%) practices. A total of 33.7 million antibiotic prescriptions were issued to a registered population of 53.8 million patients. Antibiotic prescribing volume was a significant positive predictor of all 'doctor satisfaction' and 'practice satisfaction' scores in the GPPS, and was the strongest predictor of overall satisfaction out of 13 prescribing variables. A theoretical 25% reduction in antibiotic prescribing volume would be associated with 0.5-1.0% lower patient satisfaction scores, a drop of 3-6 centile points in national satisfaction ranking. Patients were less satisfied in practices with frugal antibiotic prescribing. A cautious approach to antibiotic prescribing may require a trade-off in terms of patient satisfaction. © British Journal of General Practice 2016.

  17. Prevention of potentially inappropriate prescribing for elderly patients: a randomized controlled trial using STOPP/START criteria.

    LENUS (Irish Health Repository)

    Gallagher, P F

    2011-06-01

    Inappropriate prescribing is particularly common in older patients and is associated with adverse drug events (ADEs), hospitalization, and wasteful utilization of resources. We randomized 400 hospitalized patients aged ≥ 65 years to receive either the usual pharmaceutical care (control) or screening with STOPP\\/START criteria followed up with recommendations to their attending physicians (intervention). The Medication Appropriateness Index (MAI) and Assessment of Underutilization (AOU) index were used to assess prescribing appropriateness, both at the time of discharge and for 6 months after discharge. Unnecessary polypharmacy, the use of drugs at incorrect doses, and potential drug-drug and drug-disease interactions were significantly lower in the intervention group at discharge (absolute risk reduction 35.7%, number needed to screen to yield improvement in MAI = 2.8 (95% confidence interval 2.2-3.8)). Underutilization of clinically indicated medications was also reduced (absolute risk reduction 21.2%, number needed to screen to yield reduction in AOU = 4.7 (95% confidence interval 3.4-7.5)). Significant improvements in prescribing appropriateness were sustained for 6 months after discharge.

  18. Age, Sex, and Dose Effects of Nonbenzodiazepine Hypnotics on Hip Fracture in Nursing Home Residents.

    Science.gov (United States)

    Dore, David D; Zullo, Andrew R; Mor, Vincent; Lee, Yoojin; Berry, Sarah D

    2018-04-01

    The Food and Drug Administration recommends a reduced dose of nonbenzodiazepine hypnotics in women, yet little is known about the age-, sex-, and dose-specific effects of these drugs on risk of hip fracture, especially among nursing home (NH) residents. We estimated the age-, sex-, and dose-specific effects of nonbenzodiazepine hypnotics on the rate of hip fracture among NH residents. Case-crossover study in US NHs. A total of 691 women and 179 men with hip fracture sampled from all US long-stay NH residents. Measures of patient characteristics were obtained from linked Medicare and the Minimum Data Set (2007-2008). The outcome was hospitalization for hip fracture with surgical repair. We estimated rate ratios (RRs) and 95% confidence intervals (CIs) from conditional logistic regression models for nonbenzodiazepine hypnotics (vs nonuse) comparing 0 to 29 days before hip fracture (hazard period) with 60 to 89 and 120 to 149 days before hip fracture (control periods). We stratified analyses by age, sex, and dose. The average RR of hip fracture was 1.7 (95% CI 1.5-1.9) for any use. The RR of hip fracture was higher for residents aged ≥90 years vs <70 years (2.2 vs 1.3); however, the CIs overlapped. No differences in the effect of the hypnotic on risk of hip fracture were evident by sex. Point estimates for hip fracture were greater with high-dose versus low-dose hypnotics (RR 1.9 vs 1.6 for any use), but these differences were highly compatible with chance. The rate of hip fracture in NH residents due to use of nonbenzodiazepine hypnotics was greater among older patients than among younger patients and, possibly, with higher doses than with lower doses. When clinicians are prescribing a nonbenzodiazepine hypnotic to any NH resident, doses of these drugs should be kept as low as possible, especially among those with advanced age. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  19. Should we routinely remove the dose delivered by the images of control?

    International Nuclear Information System (INIS)

    Goasduff, G.; Pene Baverez, D.; Pradier, O.; Bouchekoua, M.

    2009-01-01

    The constraints of doses fixed by the international commission on radiation units and measurements (ICRU) for the target volume (95-107% of the prescribed dose) are respected. for the hypo fractionated treatments, it is necessary to control the impact of the dose delivered by the control images for every patient. The dose delivered at the isocenter is estimated between 1 and 3 Gy by control image: this dose depends on the beams size and on the distance-source-skin. Protocols of the patient positioning checking must be implemented on optimizing their frequency to limit the dose received by the patient. (N.C.)

  20. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  1. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  2. Balancing patient dose and image quality

    International Nuclear Information System (INIS)

    Martin, C.J.; Sutton, D.G.; Sharp, P.F.

    1999-01-01

    The formation of images in diagnostic radiology involves a complex interdependence of many factors. The ideal balance is to obtain an image which is adequate for the clinical purpose with the minimum radiation dose. Factors which affect radiation dose and image quality can be grouped under three headings; radiation quality, photon fluence and removal of scattered radiation. If optimal performance is to be achieved, it is necessary to understand how these factors influence image formation and affect radiation dose, and apply methodology for image quality and dose analysis at each stage in the development and use of X-ray equipment

  3. e-Learning initiatives to support prescribing

    Science.gov (United States)

    Maxwell, Simon; Mucklow, John

    2012-01-01

    Preparing medical students to prescribe is a major challenge of undergraduate education. They must develop an understanding of clinical pharmacology and acquire knowledge about drugs and therapeutics, as well as the skills to prescribe for individual patients in the face of multiple variables. The task of delivering the learning required to achieve these attributes relies upon limited numbers of teachers, who have increasingly busy clinical commitments. There is evidence that training is currently insufficient to meet the demands of the workplace. e-Learning provides an opportunity to improve the learning experience. The advantages for teachers are improved distribution of learning content, ease of update, standardization and tracking of learner activities. The advantages for learners are ease of access, greater interactivity and individual choice concerning the pace and mix of learning. Important disadvantages are the considerable resource required to develop e-Learning projects and difficulties in simulating some aspects of the real world prescribing experience. Pre-requisites for developing an e-Learning programme to support prescribing include academic expertise, institutional support, learning technology services and an effective virtual learning environment. e-Learning content might range from complex interactive learning sessions through to static web pages with links. It is now possible to simulate and provide feedback on prescribing decisions and this will improve with advances in virtual reality. Other content might include a student formulary, self-assessment exercises (e.g. calculations), a glossary and an on-line library. There is some evidence for the effectiveness of e-Learning but better research is required into its potential impact on prescribing. PMID:22509885

  4. ELECTORAL PRESCRIBERS. WHO ARE THEY?

    Directory of Open Access Journals (Sweden)

    Constantin SASU

    2016-12-01

    Full Text Available The decision to vote and choosing among the candidates is an extremely important one with repercussions on everyday life by determining, in global mode, its quality for the whole society. Therefore the whole process by which the voter decides becomes a central concern. Prescribers, supposed to have a big influence on the electoral market, are a component of the microenvironment political organizations. These are people who occupy important positions that can influence the behavior of others. In the political environment, prescribers are known under the name of "opinion formers", "opinion leaders", "mediators" (Beciu, 2009 or "influencers" (Keller and Berry, 2003 Weimann, 1994. This paper aims to review the central opinions on what is the influence prescribers, opinion makers on voting behavior, voting and decisions on whether and how they act?

  5. Effective dose to radon considering people's activities

    International Nuclear Information System (INIS)

    Shimo, M.; Seki, K.; Kikuchi, I.

    1992-01-01

    The tidal volume was estimated for evaluating the effective dose due to radon concentration in the atmosphere. In this study regional population was separated to vocation and non-vocation. The occupancy time and the breathing rate for both vocation and non-vocation groups were estimated, and the annual tidal volume for both groups were calculated. Human actions were separated to 18 activities in the process for estimating the breathing rate. It was clear that the breathing rate depended on human activity and that the human activity changed with its age, so the breathing rate varied with age. Finally the effective doses due to radon and radon progeny indoors and outdoors were evaluated. The maximum annual effective dose was estimated to be 1.2 mSv, minimum 0.2 mSv, and mean 0.51 mSv for vocation. For non-vocation, the male maximum value 0.43 mSv was obtained at the 16 age and the minimum 0.12 mSv at the 70 age, whereas female maximum 0.26 mSv was obtained at the 12 age and the minimum 0.11 mSv at the 70 age. In addition in this study objective areas are Aichi, Gifu, and Mie prefectures for vocation and only Aichi prefecture for non-vocation. (author)

  6. Factors Influencing Patterns of Antibiotic Prescribing in Primary Health Care Centers in the Savodjbolaq District During 2012-13: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Gh. Karimi

    2015-08-01

    Full Text Available Background and Objective: Inappropriate prescribing of antibiotics is one of the main reasons for antibiotic resistance in the world which has an increasing pressure and cost on health system and also household economy. The present study aimed to determine the pattern of antibiotic prescribing and related it,s factors in health centers. Materials and Methods: In a cross-sectional design, 1068 random prescriptions of General Physicians (GPs who work in Savodjbolaq Health Centers were studied. Variables included age, gender of patients and physicians, frequency of antibiotic prescribing, rate of combination therapy, methods of prescribing, type of patient’s insurance booklet and seasons. Statistical analysis was performed by SPSS version 18 software. Results: More than half of prescriptions (56.8% included at least one antibiotics. One in every four prescriptions had some sort of antibiotic combination therapy. According to the scientific criteria, 57.1% of antibiotics were prescribed inappropriately. among these criteria, the highest error belongs to doses per day with 67.72%. Frequency of antibiotic prescribing based on age, gender, type of patient’s insurance booklet, physicians experience, different seasons was significantly different (p<0.05. Conclusions: Combination therapy and unscientific prescribing of antibiotics for youths are concern for public health and household economy. Review of protocols and methods of supervision, Changes in purchasing medical services, Design and implementation of operational and targeted educational interventions, Training physicians emphasizing on logical aspects of antibiotic prescription and prescribing skills, are recommended.  

  7. Personalized versus standardized dosing strategies for the treatment of childhood amblyopia: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Moseley, Merrick J; Wallace, Michael P; Stephens, David A; Fielder, Alistair R; Smith, Laura C; Stewart, Catherine E

    2015-04-25

    Amblyopia is the commonest visual disorder of childhood in Western societies, affecting, predominantly, spatial visual function. Treatment typically requires a period of refractive correction ('optical treatment') followed by occlusion: covering the nonamblyopic eye with a fabric patch for varying daily durations. Recent studies have provided insight into the optimal amount of patching ('dose'), leading to the adoption of standardized dosing strategies, which, though an advance on previous ad-hoc regimens, take little account of individual patient characteristics. This trial compares the effectiveness of a standardized dosing strategy (that is, a fixed daily occlusion dose based on disease severity) with a personalized dosing strategy (derived from known treatment dose-response functions), in which an initially prescribed occlusion dose is modulated, in a systematic manner, dependent on treatment compliance. A total of 120 children aged between 3 and 8 years of age diagnosed with amblyopia in association with either anisometropia or strabismus, or both, will be randomized to receive either a standardized or a personalized occlusion dose regimen. To avoid confounding by the known benefits of refractive correction, participants will not be randomized until they have completed an optical treatment phase. The primary study objective is to determine whether, at trial endpoint, participants receiving a personalized dosing strategy require fewer hours of occlusion than those in receipt of a standardized dosing strategy. Secondary objectives are to quantify the relationship between observed changes in visual acuity (logMAR, logarithm of the Minimum Angle of Resolution) with age, amblyopia type, and severity of amblyopic visual acuity deficit. This is the first randomized controlled trial of occlusion therapy for amblyopia to compare a treatment arm representative of current best practice with an arm representative of an entirely novel treatment regimen based on statistical

  8. The social act of electronic medication prescribing.

    Science.gov (United States)

    Aarts, Jos

    2013-01-01

    Prescribing medication is embedded in social norms and cultures. In modern Western health care professionals and policy makers have attempted to rationalize medicine by addressing cost-effectiveness of diagnostic and therapeutic treatments and the development of guidelines and protocols based on the outcomes of clinical studies. These notions of cost-effectiveness and evidence-based medicine have also been embedded in technology such as electronic prescribing systems. Such constraining systems may clash with the reality of clinical practice, where formal boundaries of responsibility and authorization are often blurred. Such systems may therefore even impede patient care. Medication is seen as the essence of medical practice. Prescribing is a social act. In a hospital medications may be aimed at treating a patient for a specific condition, in primary care the professional often meets the patient with her or his social and cultural notions of a health problem. The author argues that the design and implementation of electronic prescribing systems should address the social and cultural context of prescribing. Especially in primary care, where health problems are often ill defined and evidence-based medicine guidelines do not always work as intended, studies need to take into account the sociotechnical character of electronic prescribing systems.

  9. Customization in prescribing for bipolar disorder.

    Science.gov (United States)

    Hodgkin, Dominic; Volpe-Vartanian, Joanna; Merrick, Elizabeth L; Horgan, Constance M; Nierenberg, Andrew A; Frank, Richard G; Lee, Sue

    2012-06-01

    For many disorders, patient heterogeneity requires physicians to customize their treatment to each patient's needs. We test for the existence of customization in physicians' prescribing for bipolar disorder, using data from a naturalistic clinical effectiveness trial of bipolar disorder treatment (STEP-BD), which did not constrain physician prescribing. Multinomial logit is used to model the physician's choice among five combinations of drug classes. We find that our observed measure of the patient's clinical status played only a limited role in the choice among drug class combinations, even for conditions such as mania that are expected to affect class choice. However, treatment of a patient with given characteristics differed widely depending on which physician was seen. The explanatory power of the model was low. There was variation within each physician's prescribing, but the results do not suggest a high degree of customization in physicians' prescribing, based on our measure of clinical status. Copyright © 2011 John Wiley & Sons, Ltd.

  10. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    International Nuclear Information System (INIS)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K

    2015-01-01

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003

  11. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K [Osaka University, Suita, Osaka (Japan)

    2015-06-15

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003.

  12. Age-dependent dose coefficients for tritium in Asian populations

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A

    1999-10-01

    The International Commission on Radiological Protection (ICRP) Publications 56 (1989) and 67 (1993) have prescribed the biokinetic models and age-dependent dose coefficients for tritiated water and organically bound tritium. The dose coefficients are computed from values selected to specify the anatomical, morphological and physiological characteristics of a three-month-old, one-year-old, five-year-old, 10-year-old, 15-year-old and adult (Reference Man) Caucasian living in North America and Western Europe. However, values for Reference Man and other age groups are not directly applicable to Asians, because of differences in race, custom, dietary habits and climatic conditions. An Asian Man model, including five age groups, has been proposed by Tanaka and Kawamura (1996, 1998) for use in internal dosimetry. The basic concept of the ICRP Reference Man and the system describing body composition in ICRP Publication 23 (1975) were used. Reference values for Asians were given for the body weight and height, the mass of soft tissue, the mass of body water and the daily fluid balance, and are used to compute the dose coefficients for tritium. The age-dependent dose coefficients for Asians for tritiated water intakes are smaller by 20 to 30% of the currently prescribed values (Trivedi, 1998). The reduction in the dose coefficient values is caused by the increased daily fluid balance among Asians. The dose coefficient for tritiated water is 1.4 x 10{sup -11} Sv Bq{sup -1} for Asian Man compared to 2.0 x 10{sup -11} Sv Bq{sup -1} for Reference Man. The dose coefficients for organically bound tritium are only marginally different from those of the ICRP values. The dose coefficient for organically bound tritium for Asian Man is 4.0 x 10{sup -11} Sv Bq{sup -11} compared to 4.6 x 10{sup -11} Sv Bq{sup -1} for Reference Man. (author)

  13. Age-dependent dose coefficients for tritium in Asian populations

    International Nuclear Information System (INIS)

    Trivedi, A.

    1999-10-01

    The International Commission on Radiological Protection (ICRP) Publications 56 (1989) and 67 (1993) have prescribed the biokinetic models and age-dependent dose coefficients for tritiated water and organically bound tritium. The dose coefficients are computed from values selected to specify the anatomical, morphological and physiological characteristics of a three-month-old, one-year-old, five-year-old, 10-year-old, 15-year-old and adult (Reference Man) Caucasian living in North America and Western Europe. However, values for Reference Man and other age groups are not directly applicable to Asians, because of differences in race, custom, dietary habits and climatic conditions. An Asian Man model, including five age groups, has been proposed by Tanaka and Kawamura (1996, 1998) for use in internal dosimetry. The basic concept of the ICRP Reference Man and the system describing body composition in ICRP Publication 23 (1975) were used. Reference values for Asians were given for the body weight and height, the mass of soft tissue, the mass of body water and the daily fluid balance, and are used to compute the dose coefficients for tritium. The age-dependent dose coefficients for Asians for tritiated water intakes are smaller by 20 to 30% of the currently prescribed values (Trivedi, 1998). The reduction in the dose coefficient values is caused by the increased daily fluid balance among Asians. The dose coefficient for tritiated water is 1.4 x 10 -11 Sv Bq -1 for Asian Man compared to 2.0 x 10 -11 Sv Bq -1 for Reference Man. The dose coefficients for organically bound tritium are only marginally different from those of the ICRP values. The dose coefficient for organically bound tritium for Asian Man is 4.0 x 10 -11 Sv Bq -11 compared to 4.6 x 10 -11 Sv Bq -1 for Reference Man. (author)

  14. Dose-volume analysis of predictors for chronic rectal toxicity after treatment of prostate cancer with adaptive image-guided radiotherapy

    International Nuclear Information System (INIS)

    Vargas, Carlos; Martinez, Alvaro; Kestin, Larry L.; Yan Di; Grills, Inga; Brabbins, Donald S.; Lockman, David M.; Liang Jian; Gustafson, Gary S.; Chen, Peter Y.; Vicini, Frank A.; Wong, John W.

    2005-01-01

    Purpose We analyzed our experience treating localized prostate cancer with image-guided off-line correction with adaptive high-dose radiotherapy (ART) in our Phase II dose escalation study to identify factors predictive of chronic rectal toxicity. Materials and Methods From 1999-2002, 331 patients with clinical stage T1-T3N0M0 prostate cancer were prospectively treated in our Phase II 3D conformal dose escalation ART study to a median dose of 75.6 Gy (range, 63.0-79.2 Gy), minimum dose to confidence limited-planning target volume (cl-PTV) in 1.8 Gy fractions (median isocenter dose = 79.7 Gy). Seventy-four patients (22%) also received neoadjuvant/adjuvant androgen deprivation therapy. A patient-specific cl-PTV was constructed using 5 computed tomography scans and 4 sets of electronic portal images by applying an adaptive process to assure target accuracy and minimize PTV margin. For each case, the rectum (rectal solid) was contoured from the sacroiliac joints or rectosigmoid junction (whichever was higher) to the anal verge or ischial tuberosities (whichever was lower), with a median volume of 81.2 cc. The rectal wall was defined using the rectal solid with an individualized 3-mm wall thickness (median volume = 29.8 cc). Rectal wall dose-volume histogram was used to determine the prescribed dose. Toxicity was quantified using the National Cancer Institute Common Toxicity Criteria 2.0. Multiple dose-volume endpoints were evaluated for their association with chronic rectal toxicity. Results Median follow-up was 1.6 years. Thirty-four patients (crude rate 10.3%) experienced Grade 2 chronic rectal toxicity at a median interval of 1.1 years. Nine patients (crude rate = 2.7%) experienced Grade ≥3 chronic rectal toxicity (1 was Grade 4) at a median interval of 1.2 years. The 3-year rates of Grade ≥2 and Grade ≥3 chronic rectal toxicity were 20% and 4%, respectively. Acute toxicity predicted for chronic: Acute Grade 2-3 rectal toxicity (p 40% respectively. The volume

  15. Is it safe to prescribe clomiphene citrate without ultrasound monitoring facilities?

    LENUS (Irish Health Repository)

    Coughlan, C

    2010-05-01

    The majority of triplet and higher order multiple pregnancies now result from ovulation induction\\/superovulation rather than in vitro fertilisation. However, clomiphene citrate is still widely prescribed by gynaecologists and general practitioners who do not have access to ultrasound monitoring. The objective of our study was to determine the prevalence of multifollicular development with different doses of clomiphene citrate. A retrospective review of transvaginal ultrasound monitoring of 425 cycles in 182 women receiving clomiphene citrate from January 2002 to December 2003, was studied. Three or more follicles of >or= 14 mm were identified in 58 cycles (14%). Patients received 50 mg of clomiphene citrate in 52 of these 58 cycles and 25 mg in the remaining six. One patient was noted to have developed five follicles and 10 patients developed four follicles. One patient developed six follicles, despite receiving only 25 mg clomiphene citrate daily. It was concluded that a significant number of women (14%) developed three or more follicles, despite receiving low doses of clomiphene citrate.

  16. Prescribers and pharmaceutical representatives: why are we still meeting?

    Science.gov (United States)

    Fischer, Melissa A; Keough, Mary Ellen; Baril, Joann L; Saccoccio, Laura; Mazor, Kathleen M; Ladd, Elissa; Von Worley, Ann; Gurwitz, Jerry H

    2009-07-01

    Research suggests that pharmaceutical marketing influences prescribing and may cause cognitive dissonance for prescribers. This work has primarily been with physicians and physician-trainees. Questions remain regarding why prescribers continue to meet with pharmaceutical representatives (PRs). To describe the reasons that prescribers from various health professions continue to interact with PRs despite growing evidence of the influence of these interactions. Multi-disciplinary focus groups with 61 participants held in practice settings and at society meetings. Most prescribers participating in our focus groups believe that overall PR interactions are beneficial to patient care and practice health. They either trust the information from PRs or feel that they are equipped to evaluate it independently. Despite acknowledgement of study findings to the contrary, prescribers state that they are able to effectively manage PR interactions such that their own prescribing is not adversely impacted. Prescribers describe few specific strategies or policies for these interactions, and report that policies are not consistently implemented with all members of a clinic or institution. Some prescribers perceive an inherent contradiction between academic centers and national societies receiving money from pharmaceutical companies, and then recommending restriction at the level of the individual prescriber. Prescribers with different training backgrounds present a few novel reasons for these meetings. Despite evidence that PR detailing influences prescribing, providers from several health professions continue to believe that PR interactions improve patient care, and that they can adequately evaluate and filter information presented to them by PRs. Focus group comments suggest that cultural change is necessary to break the norms that exist in many settings. Applying policies consistently, considering non-physician members of the healthcare team, working with trainees, restructuring

  17. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks

    International Nuclear Information System (INIS)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters; Silva, Ricardo Goulart da; Viamonte, Alfredo

    2011-01-01

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  18. Impact of a warning CPOE system on the inappropriate pill splitting of prescribed medications in outpatients.

    Directory of Open Access Journals (Sweden)

    Chia-Chen Hsu

    Full Text Available Prescribing inappropriate pill splitting is not rare in clinical practice. To reduce inappropriate pill splitting, we developed an automatic warning system linked to a computerized physician order entry (CPOE system for special oral formulation drugs in outpatient settings. We examined the impact of the warning system on inappropriate prescribing of pill splitting and assess prescribers' responses to the warnings.Drugs with extended-release or enteric-coated formulations that were not originally intended to be split were recognized as "special oral formulations". A hard-stop system which could examine non-integer doses of drugs with special oral formulations, provide warnings to interrupt inappropriate prescriptions was integrated in CPOE in a medical center since June 2010. We designed an intervention study to compare the inappropriate splitting before and after the implementation of the warning system (baseline period 2010 January to May vs. intervention period 2010 June to 2011 August. During the intervention period, prescription changes in response to a warning were logged and analyzed.A total of 470,611 prescribed drug items with 34 different drugs with special oral formulations were prescribed in the study period. During the 15-month intervention period, 909 warnings for 26 different drugs were triggered among 354,523 prescribed drug items with special oral formulations. The warning rate of inappropriate splitting in the late intervention period was lower than those in baseline period (0.16% vs. 0.61%, incidence rate ratio 0.27, 95% CI 0.23-0.31, P<0.001. In respond to warnings, physicians had to make adjustments, of which the majority was changing to an unsplit pill (72.9%.The interruptive warning system could avoid the prescriptions with inappropriate pill splitting. Accordingly, physicians changed their behavior of prescribing special oral formulations regarding inappropriate pill splitting. We suggest the establishment of such system

  19. Antibiotic Utilization and Prescribing Patterns in a Nigerian ...

    African Journals Online (AJOL)

    The study of prescribing pattern seeks to monitor, evaluate and suggest a modification in prescriber's prescribing habits so as to make medical care rational and cost effective. Information about antibiotic use pattern is necessary for a constructive approach to problems that arise from multiple antibiotics available. To identify ...

  20. Comparison of Psychotropic Drug Prescribing Quality between Zagreb, Croatia and Sarajevo, B&H.

    Science.gov (United States)

    Polić-Vižintin, Marina; Štimac, Danijela; Čatić, Tarik; Šostar, Zvonimir; Zelić, Ana; Živković, Krešimir; Draganić, Pero

    2014-12-01

    The purpose of this paper was to compare outpatient consumption and quality of psychotropic drug prescribing between Croatia and Bosnia & Herzegovina 2006-2010. Data on drug utilization from Zagreb Municipal Pharmacy and Sarajevo Public Pharmacy were used to calculate the number of defined daily doses (DDD) and DDD per 1000 inhabitants per day (DDD/TID) using the WHO Anatomical-Therapeutic-Chemical methodology. Total utilization of psychopharmaceuticals increased in both cities; however, it was higher in Zagreb than in Sarajevo throughout the study period. The utilization of psycholeptics increased in Zagreb by 2.4% (from 74.5 to 76.3 DDD/TID) and in Sarajevo by 3.8% (from 62.4 to 64.8 DDD/TID). The utilization of anxiolytics decreased in Zagreb by 2.1% and in Sarajevo by even 18.7%. The utilization of antidepressants increased in both cities with predominance of SSRI over TCA utilization, greater in Sarajevo (96.6%) than in Zagreb (10.2%). The anxiolytic/antidepressant ratio decreased by 11.1% in Zagreb (from 2.87 to 2.55) and by 58.7% in Sarajevo (from 5.66 to 2.34). Outpatient utilization of antipsychotics increased significantly in Sarajevo, predominated by typical ones, whereas in Zagreb the utilization of antipsychotics was stable, predominated by atypical ones. In Croatia and Bosnia & Herzegovina, there was an obvious tendency to follow western trends in drug prescribing, as demonstrated by the increased use of antidepressants and reduced use of anxiolytics. Despite some improvement observed in the prescribing quality, high use of antipsychotics with dominance of typical antipsychotics in Sarajevo points to the need of prescribing guidelines for antipsychotics.

  1. e-Learning initiatives to support prescribing.

    Science.gov (United States)

    Maxwell, Simon; Mucklow, John

    2012-10-01

    Preparing medical students to prescribe is a major challenge of undergraduate education. They must develop an understanding of clinical pharmacology and acquire knowledge about drugs and therapeutics, as well as the skills to prescribe for individual patients in the face of multiple variables. The task of delivering the learning required to achieve these attributes relies upon limited numbers of teachers, who have increasingly busy clinical commitments. There is evidence that training is currently insufficient to meet the demands of the workplace. e-Learning provides an opportunity to improve the learning experience. The advantages for teachers are improved distribution of learning content, ease of update, standardization and tracking of learner activities. The advantages for learners are ease of access, greater interactivity and individual choice concerning the pace and mix of learning. Important disadvantages are the considerable resource required to develop e-Learning projects and difficulties in simulating some aspects of the real world prescribing experience. Pre-requisites for developing an e-Learning programme to support prescribing include academic expertise, institutional support, learning technology services and an effective virtual learning environment. e-Learning content might range from complex interactive learning sessions through to static web pages with links. It is now possible to simulate and provide feedback on prescribing decisions and this will improve with advances in virtual reality. Other content might include a student formulary, self-assessment exercises (e.g. calculations), a glossary and an on-line library. There is some evidence for the effectiveness of e-Learning but better research is required into its potential impact on prescribing. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  2. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    Science.gov (United States)

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Personal and professional challenges of nurse prescribing in Ireland.

    Science.gov (United States)

    McBrien, Barry

    This article presents the challenges regarding the development of a collaborative practice agreement in order to undertake nurse prescribing in an emergency department in a large teaching hospital. Nurse prescribing has been introduced quite recently in Ireland. Although there is a plethora of knowledge regarding the topic, there are many personal and professional challenges in relation to this emerging role. The nurse prescribing initiative in Ireland is continually developing and many nurses now have the authority to prescribe from almost the same range of medicines as doctors. Prescribing has the potential to improve job satisfaction, autonomy and ultimately improves patient outcomes. However, nurses need to be cognisant of the impact it can have on the dynamics of the healthcare team. An analysis of some complexities of nurse prescribing is given, in conjunction with reflective thoughts on a clinical incident in the area of morphine prescribing.

  4. Receptionist input to quality and safety in repeat prescribing in UK general practice: ethnographic case study.

    Science.gov (United States)

    Swinglehurst, Deborah; Greenhalgh, Trisha; Russell, Jill; Myall, Michelle

    2011-11-03

    To describe, explore, and compare organisational routines for repeat prescribing in general practice to identify contributors and barriers to safety and quality. Ethnographic case study. Four urban UK general practices with diverse organisational characteristics using electronic patient records that supported semi-automation of repeat prescribing. 395 hours of ethnographic observation of staff (25 doctors, 16 nurses, 4 healthcare assistants, 6 managers, and 56 reception or administrative staff), and 28 documents and other artefacts relating to repeat prescribing locally and nationally. Potential threats to patient safety and characteristics of good practice. Observation of how doctors, receptionists, and other administrative staff contributed to, and collaborated on, the repeat prescribing routine. Analysis included mapping prescribing routines, building a rich description of organisational practices, and drawing these together through narrative synthesis. This was informed by a sociological model of how organisational routines shape and are shaped by information and communications technologies. Results Repeat prescribing was a complex, technology-supported social practice requiring collaboration between clinical and administrative staff, with important implications for patient safety. More than half of requests for repeat prescriptions were classed as "exceptions" by receptionists (most commonly because the drug, dose, or timing differed from what was on the electronic repeat list). They managed these exceptions by making situated judgments that enabled them (sometimes but not always) to bridge the gap between the idealised assumptions about tasks, roles, and interactions that were built into the electronic patient record and formal protocols, and the actual repeat prescribing routine as it played out in practice. This work was creative and demanded both explicit and tacit knowledge. Clinicians were often unaware of this input and it did not feature in policy

  5. Control of invasive weeds with prescribed burning

    Science.gov (United States)

    DiTomaso, Joseph M.; Brooks, Matthew L.; Allen, Edith B.; Minnich, Ralph; Rice, Peter M.; Kyser, Guy B.

    2006-01-01

    Prescribed burning has primarily been used as a tool for the control of invasive late-season annual broadleaf and grass species, particularly yellow starthistle, medusahead, barb goatgrass, and several bromes. However, timely burning of a few invasive biennial broadleaves (e.g., sweetclover and garlic mustard), perennial grasses (e.g., bluegrasses and smooth brome), and woody species (e.g., brooms and Chinese tallow tree) also has been successful. In many cases, the effectiveness of prescribed burning can be enhanced when incorporated into an integrated vegetation management program. Although there are some excellent examples of successful use of prescribed burning for the control of invasive species, a limited number of species have been evaluated. In addition, few studies have measured the impact of prescribed burning on the long-term changes in plant communities, impacts to endangered plant species, effects on wildlife and insect populations, and alterations in soil biology, including nutrition, mycorrhizae, and hydrology. In this review, we evaluate the current state of knowledge on prescribed burning as a tool for invasive weed management.

  6. Comparison of equations for dosing of medications in renal impairment.

    Science.gov (United States)

    Khanal, Aarati; Peterson, Gregory M; Jose, Matthew D; Castelino, Ronald L

    2017-06-01

    The aim of this study is to determine the concordance among the Cockcroft-Gault, the Modification of Diet in Renal Disease and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in hypothetical dosing of renally cleared medications. A total of 2163 patients prescribed at least one of the 31 renally cleared drugs under review were included in the study. Kidney function was estimated using the three equations. We compared actual prescribed dosages of the same drug with recommended dosages based on the kidney function as calculated by each of the equations and applying dosing recommendations in the Australian Medicines Handbook. There was a significant difference in the kidney function values estimated from the three equations (P < 0.001). Despite the good overall agreement in renal drug dosing, we found selected but potentially important discrepancies among the doses rendered from the equations. The CKD-EPI equation non-normalized for body surface area had a greater rate of concordance with the Cockcroft-Gault equation than the Modification of Diet in Renal Disease equation for renal drug dosing. There is need for a long-term multi-centre study in a diverse population to define the clinical effects of the discrepancies among the equations for drug dosing. Given the greater concordance of the non-normalized CKD-EPI equation with the Cockcroft-Gault equation for dosing, the recommendation by Kidney Health Australia and the United States National Kidney Disease Education Program that 'dosing based on either eCrCl or an eGFR with body surface area normalization removed are acceptable' seems suitable and practicable for the purpose of dosing of non-critical drugs in the primary care setting. © 2016 Asian Pacific Society of Nephrology.

  7. SU-F-J-89: Assessment of Delivered Dose in Understanding HCC Tumor Progression Following SBRT

    Energy Technology Data Exchange (ETDEWEB)

    McCulloch, M; Cazoulat, G; Polan, D; Schipper, M; Lawrence, T; Feng, M; Brock, K [University of Michigan, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: It is well documented that the delivered dose to patients undergoing radiotherapy (RT) is often different from the planned dose due to geometric variability and uncertainties in patient positioning. Recent work suggests that accumulated dose to the GTV is a better predictor of progression compared to the minimum planned dose to the PTV. The purpose of this study is to evaluate if deviations from the planned dose can contributed to tumor progression. Methods: From 2010 to 2014 an in-house Phase II clinical trial of adaptive stereotactic body RT was completed. Of the 90 patients enrolled, 7 patients had a local recurrence defined on contrast enhanced CT or MR imaging 3–21 months after completion of RT. Retrospective dose accumulation was performed using a biomechanical model-based deformable image registration algorithm (DIR) to accumulate the dose based on the kV CBCT acquired prior to each fraction for soft tissue alignment of the patient. The DIR algorithm was previously validated for geometric accuracy in the liver (target registration error = 2.0 mm) and dose accumulation in a homogeneous image, similar to a liver CBCT (gamma index = 91%). Following dose accumulation, the minimum dose to 0.5 cc of the GTV was compared between the planned and accumulated dose. Work is ongoing to evaluate the tumor control probability based on the planned and accumulated dose. Results: DIR and dose accumulation was performed on all fractions for 6 patients with local recurrence. The difference in minimum dose to 0.5 cc of the GTV ranged from −0.3–2.3 Gy over 3–5 fractions. One patient had a potentially significant difference in minimum dose of 2.3 Gy. Conclusion: Dose accumulation can reveal tumor underdosage, improving our ability to understand recurrence and tumor progression patterns, and could aid in adaptive re-planning during therapy to correct for this. This work was supported in part by NIH P01CA059827.

  8. TU-EF-204-03: Task-Based KV and MAs Optimization for Radiation Dose Reduction in CT: From FBP to Statistical Model-Based Iterative Reconstruction (MBIR)

    International Nuclear Information System (INIS)

    Gomez-Cardona, D; Li, K; Lubner, M G; Pickhardt, P J; Chen, G-H

    2015-01-01

    Purpose: The introduction of the highly nonlinear MBIR algorithm to clinical CT systems has made CNR an invalid metric for kV optimization. The purpose of this work was to develop a task-based framework to unify kV and mAs optimization for both FBP- and MBIR-based CT systems. Methods: The kV-mAs optimization was formulated as a constrained minimization problem: to select kV and mAs to minimize dose under the constraint of maintaining the detection performance as clinically prescribed. To experimentally solve this optimization problem, exhaustive measurements of detectability index (d’) for a hepatic lesion detection task were performed at 15 different mA levels and 4 kV levels using an anthropomorphic phantom. The measured d’ values were used to generate an iso-detectability map; similarly, dose levels recorded at different kV-mAs combinations were used to generate an iso-dose map. The iso-detectability map was overlaid on top of the iso-dose map so that for a prescribed detectability level d’, the optimal kV-mA can be determined from the crossing between the d’ contour and the dose contour that corresponds to the minimum dose. Results: Taking d’=16 as an example: the kV-mAs combinations on the measured iso-d’ line of MBIR are 80–150 (3.8), 100–140 (6.6), 120–150 (11.3), and 140–160 (17.2), where values in the parentheses are measured dose values. As a Result, the optimal kV was 80 and optimal mA was 150. In comparison, the optimal kV and mA for FBP were 100 and 500, which corresponded to a dose level of 24 mGy. Results of in vivo animal experiments were consistent with the phantom results. Conclusion: A new method to optimize kV and mAs selection has been developed. This method is applicable to both linear and nonlinear CT systems such as those using MBIR. Additional dose savings can be achieved by combining MBIR with this method. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona, M. G

  9. Concordance with prescribing information dosage recommendations for dipeptidyl-peptidase-4 inhibitors among type 2 diabetes mellitus patients with moderate to severe chronic kidney disease.

    Science.gov (United States)

    Huang, Huan; Shetty, Sharash; Bauer, Elise; Lang, Kathleen

    2018-06-01

    To estimate the proportion of patients with moderate to severe chronic kidney disease (CKD) whose initial dipeptidyl-peptidase-4 inhibitor (DPP4-i) dosage was concordant with prescribing information (label) recommendations in the United States. Adult patients with type 2 diabetes mellitus (T2DM) who initiated a DPP4-i (linagliptin, sitagliptin, saxagliptin) between 1 January 2011 and 30 June 2014 were identified using electronic medical records and administrative claims, with index date being the date of first observed DPP4-i treatment. Patients were required to have chronic kidney disease (CKD) stage 3b, 4 or 5 (estimated Glomerular Filtration Rate [eGFR] value <45 ml/min/1.73 m 2 ) during the 12 month pre-index period. Patients were classified as concordant or not concordant based on whether the first prescribed dose was consistent with label recommendations. Demographics, clinical characteristics, resource use and costs during pre-index were evaluated by DPP4-i concordance status. Of the 492 patients (323 sitagliptin, 57 saxagliptin, 112 linagliptin), 36.2% were prescribed doses that were not concordant with label recommendations (44.9% for sitagliptin, 57.9% for saxagliptin and 0% for linagliptin [which does not require dosage adjustment]). Concordant patients were slightly older (mean age 71 years vs. 68, p = .01) but had similar gender distribution (55% vs. 60% female, p = .31) compared to those who were not concordant. They had lower general health status (Charlson Comorbidity Score 2.6 vs. 2.2, p = .03), and had similar pre-index all-cause total costs ($25,245 vs. $21,972, p = .68) and lower pre-index T2DM-related costs ($1618 vs. $1922, p = .05). More than a third of DPP4-i patients with CKD stage 3b or higher were prescribed doses not concordant with DPP4-i label dosage recommendations.

  10. An analysis and comparison of commonly available United Kingdom prescribing resources.

    Science.gov (United States)

    Cox, A R; Butt, T F; Ferner, R E

    2010-08-01

    Safe prescribing requires accurate and practical information about drugs. Our objective was to measure the utility of current sources of prescribing guidance when used to inform practical prescribing decisions, and to compare current sources of prescribing guidance in the UK with idealized prescribing guidance. We developed 25 clinical scenarios. Two independent assessors rated and ranked the performance of five common sources of prescribing guidance in the UK when used to answer the clinical scenarios. A third adjudicator facilitated review of any disparities. An idealized list of contents for prescribing guidance was developed and sent for comments to academics and users of prescribing guidance. Following consultation an operational check was used to assess compliance with the idealized criteria. The main outcome measures were relative utility in answering the clinical scenarios and compliance with the idealized prescribing guidance. Current sources of prescribing guidance used in the UK differ in their utility, when measured using clinical scenarios. The British National Formulary (BNF) and EMIS LV were the best performing sources in terms of both ranking [mean rank 1·24 and 2·20] and rating [%excellent or adequate 100% and 72%]. Current sources differed in the extent to which they fulfilled criteria for ideal prescribing guidance, but the BNF, and EMIS LV to a lesser extent, closely matched the criteria. We have demonstrated how clinical scenarios can be used to assess prescribing guidance resources. Producers of prescribing guidance documents should consider our idealized template. Prescribers require high-quality information to support their practice. Our test was helpful in distinguishing between prescribing resources. Producers of prescribing guidance should consider the utility of their products to end-users, particularly in those more complex areas where prescribers may need most support. Existing UK prescribing guidance resources differ in their

  11. Nonadministration of medication doses for venous thromboembolism prophylaxis in a cohort of hospitalized patients.

    Science.gov (United States)

    Popoola, Victor O; Lau, Brandyn D; Tan, Esther; Shaffer, Dauryne L; Kraus, Peggy S; Farrow, Norma E; Hobson, Deborah B; Aboagye, Jonathan K; Streiff, Michael B; Haut, Elliott R

    2018-03-15

    Results of a study to characterize patterns of nonadministration of medication doses for venous thromboembolism (VTE) prevention among hospitalized patients are presented. The electronic records of all patients admitted to 4 floors of a medical center during a 1-month period were examined to identify patients whose records indicated at least 1 nonadministered dose of medication for VTE prophylaxis. Proportions of nonadministered doses by medication type, intended route of administration, and VTE risk categorization were compared; reasons for nonadministration were evaluated. Overall, 12.7% of all medication doses prescribed to patients in the study cohort ( n = 75) during the study period (857 of 6,758 doses in total) were not administered. Nonadministration of 1 or more doses of VTE prophylaxis medication was nearly twice as likely for subcutaneous anticoagulants than for all other medication types (231 of 1,112 doses [20.8%] versus 626 of 5,646 doses [11.2%], p < 0.001). For all medications prescribed, the most common reason for nonadministration was patient refusal (559 of 857 doses [65.2%]); the refusal rate was higher for subcutaneous anticoagulants than for all other medication categories (82.7% versus 58.8%, p < 0.001). Doses of antiretrovirals, immunosuppressives, antihypertensives, psychiatric medications, analgesics, and antiepileptics were less commonly missed than doses of electrolytes, vitamins, and gastrointestinal medications. Scheduled doses of subcutaneous anticoagulants for hospitalized patients were more likely to be missed than doses of all other medication types. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  12. Pharmacodynamic evaluation of commonly prescribed oral antibiotics against respiratory bacterial pathogens

    Directory of Open Access Journals (Sweden)

    Pignatari Antonio CC

    2011-10-01

    Full Text Available Abstract Background Upper and lower respiratory tract infections (RTIs account for a substantial portion of outpatient antibiotic utilization. However, the pharmacodynamic activity of commonly used oral antibiotic regimens has not been studied against clinically relevant pathogens. The objective of this study was to assess the probability of achieving the requisite pharmacodynamic exposure for oral antibacterial regimens commonly prescribed for RTIs in adults against bacterial isolates frequently involved in these processes (S. pneumoniae, H. influenzae, and M. catharralis. Methods Using a 5000-subject Monte Carlo simulation, the cumulative fractions of response (CFR, (i.e., probabilities of achieving requisite pharmacodynamic targets for the most commonly prescribed oral antibiotic regimens, as determined by a structured survey of medical prescription patterns, were assessed against local respiratory bacterial isolates from adults in São Paulo collected during the same time period. Minimal inhibitory concentration (MIC of 230 isolates of Streptococcus pneumoniae (103, Haemophilus influenzae (98, and Moraxella catharralis (29 from a previous local surveillance were used. Results The most commonly prescribed antibiotic regimens were azithromycin 500 mg QD, amoxicillin 500 mg TID, and levofloxacin 500 mg QD, accounting for 58% of the prescriptions. Varied doses of these agents, plus gatifloxacin, amoxicillin-clavulanate, moxifloxacin, and cefaclor made up the remaining regimens. Utilizing aggressive pharmacodynamic exposure targets, the only regimens to achieve greater than 90% CFR against all three pathogens were amoxicillin/amoxicillin-clavulanate 500 mg TID (> 91%, gatifloxacin 400 mg QD (100%, and moxifloxacin 400 mg QD (100%. Considering S. pneumoniae isolates alone, azithromycin 1000 mg QD also achieved greater than 90% CFR (91.3%. Conclusions The only regimens to achieve high CFR against all three pathogen populations in both scenarios

  13. [Medication reconciliation errors according to patient risk and type of physician prescriber identified by prescribing tool used].

    Science.gov (United States)

    Bilbao Gómez-Martino, Cristina; Nieto Sánchez, Ángel; Fernández Pérez, Cristina; Borrego Hernando, Mª Isabel; Martín-Sánchez, Francisco Javier

    2017-01-01

    To study the frequency of medication reconciliation errors (MREs) in hospitalized patients and explore the profiles of patients at greater risk. To compare the rates of errors in prescriptions written by emergency physicians and ward physicians, who each used a different prescribing tool. Prospective cross-sectional study of a convenience sample of patients admitted to medical, geriatric, and oncology wards over a period of 6 months. A pharmacist undertook the medication reconciliation report, and data were analyzed for possible associations with risk factors or prescriber type (emergency vs ward physician). A total of 148 patients were studied. Emergency physicians had prescribed for 68 (45.9%) and ward physicians for 80 (54.1%). A total of 303 MREs were detected; 113 (76.4%) patients had at least 1 error. No statistically significant differences were found between prescriber types. Factors that conferred risk for a medication error were use polypharmacy (odds ratio [OR], 3.4; 95% CI, 1.2-9.0; P=.016) and multiple chronic conditions in patients under the age of 80 years (OR, 3.9; 95% CI, 1.1-14.7; P=.039). The incidence of MREs is high regardless of whether the prescriber is an emergency or ward physician. The patients who are most at risk are those taking several medications and those under the age of 80 years who have multiple chronic conditions.

  14. Dose and Duration of Opioid Use in Patients with Cancer and Noncancer Pain at an Outpatient Hospital Setting in Malaysia.

    Science.gov (United States)

    Zin, Che S; Rahman, Norny A; Ismail, Che R; Choy, Leong W

    2017-07-01

    There are currently limited data available on the patterns of opioid prescribing in Malaysia. This study investigated the patterns of opioid prescribing and characterized the dosing and duration of opioid use in patients with noncancer and cancer pain. This retrospective, cross-sectional study was conducted at an outpatient hospital setting in Malaysia. All prescriptions for opioids (dihydrocodeine, fentanyl, morphine, and oxycodone) issued between January 2013 and December 2014 were examined. The number of prescriptions and patients, the distribution of mean daily dose, annual total days covered with opioids, and annual total opioid dose at the individual level were calculated and stratified by noncancer and cancer groups. A total of 1015 opioid prescriptions were prescribed for 347 patients from 2013 to 2014. Approximately 41.5% of patients (N = 144/347) and 58.5% (N = 203/347) were associated with noncancer and cancer diagnosis, respectively. Oxycodone (38.0%) was the highest prescribed primarily for the noncancer group. The majority of patients in both noncancer (74.3%) and cancer (60.4%) groups were receiving mean daily doses of 90 days per year) was associated with 21.8% of patients in the noncancer group and 17.5% in the cancer group. The finding from this study showed that 41.5% of opioid users at an outpatient hospital setting in Malaysia received opioids for noncancer pain and 21.8% of these users were using opioids for longer than 90 days. The average daily dose in the majority of patients in both groups of noncancer and cancer was modest. © 2016 World Institute of Pain.

  15. Growth of nurse prescribing competence: facilitators and barriers during education.

    Science.gov (United States)

    Hopia, Hanna; Karhunen, Anne; Heikkilä, Johanna

    2017-10-01

    To describe facilitators and barriers in relation to the growth of nurse prescribing competence from the perspective of the nurses studying in a prescribing programme. The number of nurses enrolled in a nurse prescribing programme is rapidly increasing in Finland. However, few studies on nurse prescribing education are available and therefore research is needed, particularly from the point of view of nurses studying in the programme. The descriptive, qualitative study used the text of student online learning diaries as data during a 14-month prescribing programme. The sample consisted of 31 nurses, public health nurses or midwives enrolled in a prescribing programme at a university of applied sciences. The data were analysed using the inductive analysis method. The growth of nurses' prescribing competence was facilitated by learning clinical examination of the patient, networking with peers, receiving support from the workplace and supervisors, doctors' positive attitude towards nurse prescribing and being able to apply competencies directly to nursing practice. The barriers to the growth of nurses' prescribing competence were unclear job description, incomplete care plans and concerns about how consultation with doctors will be organised and realised. The results show that, for the purpose of developing the new role and position of nurse prescribers, educators and nursing managers must invest more in staff awareness of nurse prescribing education and also offer more support to nurse prescribers in their workplaces. The results of this study can be used especially in countries where nurse prescribing education is only in the process of being planned or has just been started. Heads of nursing and educators in prescribing education will benefit from the results when creating expanded job descriptions for nurses and supporting networking between students during the period of training. © 2016 John Wiley & Sons Ltd.

  16. "What they see is what you get": Prescribing antibiotics for respiratory tract infections in primary care: Do high prescribers diagnose differently? An analysis of German routine data.

    Science.gov (United States)

    Hueber, Susann; Kuehlein, Thomas; Gerlach, Roman; Tauscher, Martin; Schedlbauer, Angela

    2017-01-01

    Characteristics of high and low prescribers of antibiotics in German primary care were analysed using population data. We aimed to evaluate differences in prescribing rates and factors being associated with high prescribing, and whether high prescribers made the diagnosis of perceived bacterial infections more often. Routine data were provided by the Bavarian Association of Statutory Health Insurance Physicians. Routine data are delivered by primary care practices on a quarterly basis. We analysed data from 2011 and 2012. Patients older than 15 years with respiratory tract infections consulting a primary care physician were selected (6.647 primary care practices). Patient and physician characteristics associated with high prescribing were identified using stepwise logistic regression. Mean prescribing rate of antibiotics was 24.9%. Prescribing rate for high prescribers was 43.5% compared to 8.5% for low prescribers. High prescribers made the diagnosis of perceived bacterial infections more often (Mhigh = 64.5%, Mlow = 45.2%). In the adjusted regression model, perceived bacterial infections were strongly associated with high prescribing (OR = 13.9, 95% CI [10.2, 18.8]). Treating patients with comorbidities was associated with lower prescribing of antibiotics (OR = 0.6, 95% CI [0.4, 0.8]). High prescribers had a higher practice volume, a higher degree of prescribing dominance, and were situated more often in deprived areas and in rural settings. Compared to findings of studies in other European countries, prescribing rates were low. There was a considerable difference between prescribing rates of high and low prescribers. Diagnostic labelling was the best predictor for high prescribing. Current guidelines recommend considering antibiotic treatment for patients with co-morbidities. In our study, treating a large number of high-risk patients was not associated with high prescribing.

  17. Out-Patient Prescribing Practices at Mbagathi District Hospital ...

    African Journals Online (AJOL)

    On average, each patient was prescribed 3.85 types of drugs. A total of 835 drugs were prescribed by generic name, accounting for 25.6% of total number of drugs prescribed (1,506). Out of 391 sampled prescriptions, 266 had antibiotics accounting for (68.0%). A relatively small proportion of the prescriptions, 9.5% had an ...

  18. Measuring the absorbed dose in critical organs during low rate dose brachytherapy with 137 Cs using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Torres, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J.; Andres, U.; Mendez, G.

    2003-01-01

    Intracavitary Brachytherapy is one of the most used methods for the treatment of the cervical-uterine cancer. This treatment consists in the insertion of low rate dose 137 Cs sources into the patient. The most used system for the treatment dose planning is that of Manchester. This planning is based on sources, which are considered fixed during the treatment. However, the experience has shown that, during the treatment, the sources could be displaced from its initial position, changing the dose from that previously prescribed. For this reason, it is necessary to make measurements of the absorbed dose to the surrounding organs (mainly bladder and rectum). This paper presents the results of measuring the absorbed dose using home-made LiF: Mg, Cu, P + Ptfe thermoluminescent dosimeters (TLD). Measurements were carried out in-vivo during 20 minutes at the beginning and at the end of the treatments. Results showed that the absorbed dose to the critical organs vary significantly due to the movement of the patient during the treatment. (Author)

  19. Dutch Travel Health Nurses: Prepared to Prescribe?

    NARCIS (Netherlands)

    Overbosch, Femke W.; Koeman, Susan C.; van den Hoek, Anneke; Sonder, Gerard J. B.

    2012-01-01

    Background. In travel medicine, as in other specialties, independent prescribing of medication has traditionally been the domain of practitioners like physicians, dentists, and midwives. However, a 2011 ruling in the Netherlands expands independent prescribing and introduces supplementary

  20. A population-based study of dosing and persistence with anti-dementia medications.

    LENUS (Irish Health Repository)

    Brewer, Linda

    2013-02-27

    PURPOSE: Cholinesterase inhibitors and memantine are the mainstay of pharmacological intervention for the cognitive symptoms of Alzheimer\\'s disease (AD). This study assessed the adequacy of dosing and persistence with AD medications and the predictors of these variables in the \\'real world\\' (outside the clinical trial setting). METHODS: The Health Service Executive-Primary Care Reimbursement Services prescription claims database in the Republic of Ireland contains prescription information for 1.6 million people. Patients aged >70 years who received at least two prescriptions for donepezil, rivastigmine, galantamine and memantine between January 2006 and December 2010 were included in the study. Rates of dose-maximisation were recorded by examining the initiation dose of each AD drug commenced during the study period and any subsequent dose titrations. Non-persistence was defined by a gap in prescribing of more than 63 consecutive days. Predictors of dose-maximisation and non-persistence were also analysed. RESULTS: Between January 2006 and December 2010, 20,729 patients aged >70 years received a prescription for an AD medication. Despite most patients on donepezil and memantine receiving a prescription for the maximum drug dose, this dose was maintained for 2 consecutive months in only two-thirds of patients. Patients were significantly more likely to have their doses of donepezil and memantine maximised if prescribed in more recent years (2010 vs. 2007). Rates of non-persistence were 30.1 % at 6 months and 43.8 % at 12 months. Older age [75+ vs. <75 years; hazards ratio (HR) 1.16, 95 % confidence interval (CI) 1.06-1.27] and drug type (rivastigmine vs. donepezil; HR 1.15, 95 % CI 1.03-1.27) increased the risk of non-persistence. Non-persistence was lower for those commencing therapy in more recent years (2010 vs. 2007; HR 0.81, 95 % CI 0.73-0.89, p < 0.001) and for those on multiple anti-dementia medications (HR 0.59, 95 % CI 0

  1. Evaluation of dose-volume histograms after prostate seed implantation. 4-year experience

    International Nuclear Information System (INIS)

    Hoinkis, C.; Lehmann, D.; Winkler, C.; Herrmann, T.; Hakenberg, O.W.; Wirth, M.P.

    2004-01-01

    Background and purpose: permanent interstitial brachytherapy by seed implantation is a treatment alternative for low-volume low-risk prostate cancer and a complex interdisciplinary treatment with a learning curve. Dose-volume histograms are used to assess postimplant quality. The authors evaluated their learning curve based on dose-volume histograms and analyzed factors influencing implantation quality. Patients and methods: since 1999, 38 patients with a minimum follow-up of 6 months were treated at the authors' institution with seed implantation using palladium-103 or iodine-125, initially using the preplan method and later real-time planning. Postimplant CT was performed after 4 weeks. The dose-volume indices D90, V100, V150, the D max of pre- and postplans, and the size and position of the volume receiving the prescribed dose (high-dose volume) of the postplans were evaluated. In six patients, postplan imaging both by CT and MRI was used and prostate volumes were compared with preimplant transrectal ultrasound volumes. The first five patients were treated under external supervision. Results: patients were divided into three consecutive groups for analysis of the learning curve (group 1: n = 5 patients treated under external supervision; group 2: n = 13 patients; group 3: n = 20 patients). D90 post for the three groups were 79.3%, 74.2%, and 99.9%, the V100 post were 78.6%, 73.5%, and 88.2%, respectively. The relationship between high-dose volume and prostate volume showed a similar increase as the D90, while the relationship between high-dose volume lying outside the prostate and prostate volume remained constant. The ratio between prostate volumes from transrectal ultrasound and CT imaging decreased with increasing D90 post , while the preplanning D90 and V100 remained constant. The different isotopes used, the method of planning, and the implanted activity per prostate volume did not influence results. Conclusion: a learning curve characterized by an increase

  2. Inappropriate Fentanyl Prescribing Among Nursing Home Residents in the United States.

    Science.gov (United States)

    Fain, Kevin M; Castillo-Salgado, Carlos; Dore, David D; Segal, Jodi B; Zullo, Andrew R; Alexander, G Caleb

    2017-02-01

    We quantified transdermal fentanyl prescribing in elderly nursing home residents without prior opioid use or persistent pain, and the association of individual and facility traits with opioid-naïve prescribing. Cross-sectional study. Linked Minimum Data Set (MDS) assessments; Online Survey, Certification and Reporting (OSCAR) records; and Medicare Part D claims. From a cross-section of all long-stay US nursing home residents in 2008 with an MDS assessment and Medicare Part D enrollment, we identified individuals (≥65 years old) who initiated transdermal fentanyl, excluding those with Alzheimer disease, severe cognitive impairment, cancer, or receipt of hospice care. We used Medicare Part D to select beneficiaries initiating transdermal fentanyl in 2008 and determined whether they were "opioid-naïve," defined as no opioid dispensing during the previous 60 days. We obtained resident and facility characteristics from MDS and OSCAR records and defined persistent pain as moderate-to-severe, daily pain on consecutive MDS assessments at least 90 days apart. We estimated associations of patient and facility attributes and opioid-naïve fentanyl initiation using multilevel mixed effects logistic regression modeling. Among 17,052 residents initiating transdermal fentanyl, 6190 (36.3%) were opioid-naïve and 15,659 (91.8%) did not have persistent pain. In the regression analysis with adjustments, residents who were older (ages ≥95 odds ratio [OR] 1.69, 95% confidence interval [CI] 1.46-1.95) or more cognitively impaired (moderate-to-severe cognitive impairment, OR 1.99, 95% CI 1.73-2.29) were more likely to initiate transdermal fentanyl without prior opioid use. Most nursing home residents initiating transdermal fentanyl did not have persistent pain and many were opioid-naïve. Changes in prescribing practices may be necessary to ensure Food and Drug Administration warnings are followed, particularly for vulnerable subgroups, such as the cognitively impaired

  3. Dose and diameter relationships for facial, trigeminal, and acoustic neuropathies following acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Lunsford, L. Dade

    1996-01-01

    Purpose and objective: To define the relationships between dose and tumor diameter for the risks of developing trigeminal, facial, and acoustic neuropathies after acoustic neuroma radiosurgery, a large single-institution experience was analyzed. Materials and methods: Two hundred and thirty-eight patients with unilateral acoustic neuromas who underwent Gamma knife radiosurgery between 1987-1994 with 6-91 months of follow-up (median 30 months) were studied. Minimum tumor doses were 12-20 Gy (median 15 Gy). Transverse tumor diameter varied from 0.3-5.5 cm (median 2.1 cm). The relationships of dose and diameter to the development of cranial neuropathies were delineated by multivariate logistic regression. Results: The development of post-radiosurgery neuropathies affecting cranial nerves V, VII, and VIII were correlated with minimum tumor dose and transverse tumor diameter (P min for VIII where P=0.10). A comparison of the dose-diameter response curves showed the acoustic nerve to be the most sensitive to doses of 12-16 Gy and the facial nerve to be the least sensitive. Conclusion: The risks of developing trigeminal, facial, and acoustic neuropathies following acoustic neuroma radiosurgery can be predicted from the transverse tumor diameter and the minimum tumor dose using models constructed from data presently available

  4. [Clinical applications of dosing algorithm in the predication of warfarin maintenance dose].

    Science.gov (United States)

    Huang, Sheng-wen; Xiang, Dao-kang; An, Bang-quan; Li, Gui-fang; Huang, Ling; Wu, Hai-li

    2011-12-27

    To evaluate the feasibility of clinical application for genetic based dosing algorithm in the predication of warfarin maintenance dose in Chinese population. The clinical data were collected and blood samples harvested from a total of 126 patients undergoing heart valve replacement. The genotypes of VKORC1 and CYP2C9 were determined by melting curve analysis after PCR. They were divided randomly into the study and control groups. In the study group, the first three doses of warfarin were prescribed according to the predicted warfarin maintenance dose while warfarin was initiated at 2.5 mg/d in the control group. The warfarin doses were adjusted according to the measured international normalized ratio (INR) values. And all subjects were followed for 50 days after an initiation of warfarin therapy. At the end of a 50-day follow-up period, the proportions of the patients on a stable dose were 82.4% (42/51) and 62.5% (30/48) for the study and control groups respectively. The mean durations of reaching a stable dose of warfarin were (27.5 ± 1.8) and (34.7 ± 1.8) days and the median durations were (24.0 ± 1.7) and (33.0 ± 4.5) days in the study and control groups respectively. Significant differences existed in the durations of reaching a stable dose between the two groups (P = 0.012). Compared with the control group, the hazard ratio (HR) for the duration of reaching a stable dose was 1.786 in the study group (95%CI 1.088 - 2.875, P = 0.026). The predicted dosing algorithm incorporating genetic and non-genetic factors may shorten the duration of achieving efficiently a stable dose of warfarin. And the present study validates the feasibility of its clinical application.

  5. Monte Carlo calculation of received dose from ingestion and inhalation of natural uranium

    International Nuclear Information System (INIS)

    Trobok, M.; Zupunski, Lj.; Spasic-Jokic, V.; Gordanic, V.; Sovilj, P.

    2009-01-01

    For the purpose of this study eighty samples are taken from the area Bela Crkva and Vrsac. The activity of radionuclide in the soil is determined by gamma- ray spectrometry. Monte Carlo method is used to calculate effective dose received by population resulting from the inhalation and ingestion of natural uranium. The estimated doses were compared with the legally prescribed levels. (author) [sr

  6. SU-E-J-21: Advantages of Ultra Fast Radiation Dose Delivering

    International Nuclear Information System (INIS)

    Feng, Y

    2014-01-01

    Purpose: For delivering conformed dose to a moving tumor and sparing normal tissue, we presented an innovation that was combined a linear accelerator and a storage ring to generate ultra high dose rate. This innovation allows delivering prescribed dose to a moving target in such a short time period, for an example 0.1 second, during which the displacement of the target could be ignored. Methods: The advantages of this approach were evaluated based on normal tissue sparing, feasibility, accuracy, and time saving in clinical treatment. The target volume reduction with this innovation approach was demonstrated by analyzing the values of GTVs, ITVs, and PTVs obtained from 15 patients who had been diagnosed with malignant neoplasm of lung and treated with SBRT. The processes of SBRT treatment were investigated and advantages of this innovation in improving SBRT lung treatment were evaluated. Results: With the ultra-high dose rate, the target volumes could be reduced by ∼30% to 50%. The innovation combining with IGRT technique could deliver prescribed dose to moving target accurately with simpler procedures than that of adaptive approach. This new approach could reduce the time of guiding treatment by many times. The new technique make a new strategy became feasible that was to deliver the dose to a target when it moved to a desirable location, such as away from critical organs. Conclusion: Combining with IGRT technique, this innovation could significantly improve the accuracy to deliver dose to moving targets with a shorter time than conventional techniques. The innovation opens a door for new strategies to deliver dose to moving targets

  7. South African medical students’ perceptions and knowledge about antibiotic resistance and appropriate prescribing: Are we providing adequate training to future prescribers?

    Directory of Open Access Journals (Sweden)

    Sean Wasserman,

    2017-05-01

    Full Text Available Background. Education of medical students has been identified by the World Health Organization as an important aspect of antibiotic resistance (ABR containment. Surveys from high-income countries consistently reveal that medical students recognise the importance of antibiotic prescribing knowledge, but feel inadequately prepared and require more education on how to make antibiotic choices. The attitudes and knowledge of South African (SA medical students regarding ABR and antibiotic prescribing have never been evaluated. Objective. To evaluate SA medical students’ perceptions, attitudes and knowledge about antibiotic use and resistance, and the perceived quality of education relating to antibiotics and infection. Methods. This was a cross-sectional survey of final-year students at three medical schools, using a 26-item self-administered questionnaire. The questionnaires recorded basic demographic information, perceptions about antibiotic use and ABR, sources, quality, and usefulness of current education about antibiotic use, and questions to evaluate knowledge. Hard-copy surveys were administered during whole-class lectures. Results. A total of 289 of 567 (51% students completed the survey. Ninety-two percent agreed that antibiotics are overused and 87% agreed that resistance is a significant problem in SA – higher proportions than those who thought that antibiotic overuse (63% and resistance (61% are problems in the hospitals where they had worked (p<0.001. Most reported that they would appreciate more education on appropriate use of antibiotics (95%. Only 33% felt confident to prescribe antibiotics, with similar proportions across institutions. Overall, prescribing confidence was associated with the use of antibiotic prescribing guidelines (p=0.003, familiarity with antibiotic stewardship (p=0.012, and more frequent contact with infectious diseases specialists (p<0.001. There was an overall mean correct score of 50% on the knowledge

  8. Prevalence and Predictors of Inappropriate Medications Prescribing ...

    African Journals Online (AJOL)

    Data analysis involved use of World Health Organization (WHO) prescribing indicators, Updated 2002 Beer's criteria and DRUG-REAX® system software package of MICROMEDEX (R) Healthcare Series to assess the prescribing pattern, identify potentially inappropriate medications and potential drug-drug interactions, ...

  9. Differences in the dose-volume metrics with heterogeneity correction status and its influence on local control in stereotactic body radiation therapy for lung cancer

    International Nuclear Information System (INIS)

    Ueki, Nami; Matsuo, Yukinori; Nakamura, Mitsuhiro; Narabayashi, Masaru; Sakanaka, Katsuyuki; Norihisa, Yoshiki; Mizowaki, Takashi; Hiraoka, Masahiro; Shibuya, Keiko

    2013-01-01

    The purpose of this study is to evaluate the dose-volume metrics under different heterogeneity corrections and the factors associated with local recurrence (LR) after stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC). Eighty-three patients who underwent SBRT for pathologically proven stage I NSCLC were reviewed retrospectively. The prescribed dose was 48 Gy in four fractions at the isocenter (IC) under heterogeneity correction with the Batho power law (BPL). The clinical plans were recalculated with Eclipse (Varian) for the same monitor units under the BPL and anisotropic analytical algorithm (AAA) and with no heterogeneity correction (NC). The dose at the IC, dose that covers 95% of the volume (D95), minimum dose (Min), and mean dose (Mean) of the planning target volume (PTV) were compared under each algorithm and between patients with local lesion control (LC) and LR. The IC doses under NC were significantly lower than those under the BPL and AAA. Under the BPL, the mean PTV D95, Min and Mean were 8.0, 9.4 and 7.4% higher than those under the AAA, and 9.6, 9.2 and 4.6% higher than those under NC, respectively. Under the AAA, all dose-volumetric parameters were significantly lower in T1a patients than in those with T1b and T2a. With a median follow-up of 35.9 months, LR occurred in 18 patients. Between the LC and LR groups, no significant differences were observed for any of the metrics. Even after stratification according to T-stage, no significant difference was observed between LC and LR. (author)

  10. Prescribing error at hospital discharge: a retrospective review of medication information in an Irish hospital.

    Science.gov (United States)

    Michaelson, M; Walsh, E; Bradley, C P; McCague, P; Owens, R; Sahm, L J

    2017-08-01

    Prescribing error may result in adverse clinical outcomes leading to increased patient morbidity, mortality and increased economic burden. Many errors occur during transitional care as patients move between different stages and settings of care. To conduct a review of medication information and identify prescribing error among an adult population in an urban hospital. Retrospective review of medication information was conducted. Part 1: an audit of discharge prescriptions which assessed: legibility, compliance with legal requirements, therapeutic errors (strength, dose and frequency) and drug interactions. Part 2: A review of all sources of medication information (namely pre-admission medication list, drug Kardex, discharge prescription, discharge letter) for 15 inpatients to identify unintentional prescription discrepancies, defined as: "undocumented and/or unjustified medication alteration" throughout the hospital stay. Part 1: of the 5910 prescribed items; 53 (0.9%) were deemed illegible. Of the controlled drug prescriptions 11.1% (n = 167) met all the legal requirements. Therapeutic errors occurred in 41% of prescriptions (n = 479) More than 1 in 5 patients (21.9%) received a prescription containing a drug interaction. Part 2: 175 discrepancies were identified across all sources of medication information; of which 78 were deemed unintentional. Of these: 10.2% (n = 8) occurred at the point of admission, whereby 76.9% (n = 60) occurred at the point of discharge. The study identified the time of discharge as a point at which prescribing errors are likely to occur. This has implications for patient safety and provider work load in both primary and secondary care.

  11. Safety of fentanyl initiation according to past opioid exposure among patients newly prescribed fentanyl patches

    Science.gov (United States)

    Friesen, Kevin J.; Woelk, Cornelius; Bugden, Shawn

    2016-01-01

    Background: Although a convenient opioid delivery system, transdermal fentanyl patches have caused several deaths and resulted in safety warnings reminding prescribers that fentanyl patches should be prescribed only for patients who have adequate prior exposure to opioids. We conducted a longitudinal analysis of the safety of fentanyl initiation by examining past opioid exposure among patients newly prescribed fentanyl patches. Methods: We identified all patients in the province of Manitoba who were newly prescribed fentanyl patches between Apr. 1, 2001, and Mar. 31, 2013. We converted all prior opioid use to oral morphine equivalents and determined the average daily dose in the 7–30 days before initial fentanyl patch use. Fentanyl initiation was considered unsafe if the patient’s pre-fentanyl opioid exposure was below the recommended level. Results: We identified 11 063 patients who began using fentanyl patches during the study period. Overall, fentanyl initiation was deemed unsafe in 74.1% of cases because the patient’s prior opioid exposure was inadequate. Women and patients 65 years of age and older were more likely than men and younger patients, respectively, to have inadequate prior opioid exposure (p fentanyl patches decreased significantly over the study period, from 87.0% in 2001 to 50.0% in 2012 (p fentanyl initiation improved over the study period, but still half of fentanyl patch prescriptions were written for patients with inadequate prior opioid exposure. Review of prior opioid exposure may be a simple but important way to improve the safe use of fentanyl patches. PMID:27044480

  12. Radiation doses arising from the air transport of radioactive materials

    International Nuclear Information System (INIS)

    Gelder, R.; Shaw, K.B.; Wilson, C.K.

    1989-01-01

    There is a compelling need for the transport of radioactive material by air because of the requirement by hospitals throughout the world for urgent delivery for medical purposes. Many countries have no radionuclide-producing capabilities and depend on imports: a range of such products is supplied from the United Kingdom. Many of these are short lived, which explains the need for urgent delivery. The only satisfactory method of delivery on a particular day to a particular destination is often by the use of scheduled passenger air service. The International Civil Aviation Organization's Technical Instructions for the Safe Transport of Dangerous Goods by Air (ICAO 1987-1988), prescribe the detailed requirements applicable to the international transport of dangerous goods by air. Radioactive materials are required to be separated from persons and from undeveloped photographic films or plates: minimum distances as a function of the total sum of transport indexes are given in the Instructions. A study, which included the measurement and assessment of the radiation doses resulting from the transport of radioactive materials by air from the UK, has been performed by the National Radiological Protection Board (NRPB) on behalf of the Civil Aviation Authority (CAA) and the Department of Transport (DTp)

  13. Method of predicting the mean lung dose based on a patient's anatomy and dose-volume histograms

    Energy Technology Data Exchange (ETDEWEB)

    Zawadzka, Anna, E-mail: a.zawadzka@zfm.coi.pl [Medical Physics Department, Centre of Oncology, Maria Sklodowska-Curie Memorial Cancer Center, Warsaw (Poland); Nesteruk, Marta [Faculty of Physics, University of Warsaw, Warsaw (Poland); Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich (Switzerland); Brzozowska, Beata [Faculty of Physics, University of Warsaw, Warsaw (Poland); Kukołowicz, Paweł F. [Medical Physics Department, Centre of Oncology, Maria Sklodowska-Curie Memorial Cancer Center, Warsaw (Poland)

    2017-04-01

    The aim of this study was to propose a method to predict the minimum achievable mean lung dose (MLD) and corresponding dosimetric parameters for organs-at-risk (OAR) based on individual patient anatomy. For each patient, the dose for 36 equidistant individual multileaf collimator shaped fields in the treatment planning system (TPS) was calculated. Based on these dose matrices, the MLD for each patient was predicted by the homemade DosePredictor software in which the solution of linear equations was implemented. The software prediction results were validated based on 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans previously prepared for 16 patients with stage III non–small-cell lung cancer (NSCLC). For each patient, dosimetric parameters derived from plans and the results calculated by DosePredictor were compared. The MLD, the maximum dose to the spinal cord (D{sub max} {sub cord}) and the mean esophageal dose (MED) were analyzed. There was a strong correlation between the MLD calculated by the DosePredictor and those obtained in treatment plans regardless of the technique used. The correlation coefficient was 0.96 for both 3D-CRT and VMAT techniques. In a similar manner, MED correlations of 0.98 and 0.96 were obtained for 3D-CRT and VMAT plans, respectively. The maximum dose to the spinal cord was not predicted very well. The correlation coefficient was 0.30 and 0.61 for 3D-CRT and VMAT, respectively. The presented method allows us to predict the minimum MLD and corresponding dosimetric parameters to OARs without the necessity of plan preparation. The method can serve as a guide during the treatment planning process, for example, as initial constraints in VMAT optimization. It allows the probability of lung pneumonitis to be predicted.

  14. Air Pollution Episodes Associated with Prescribed Burns

    Science.gov (United States)

    Hart, M.; Di Virgilio, G.; Jiang, N.

    2017-12-01

    Air pollution events associated with wildfires have been associated with extreme health impacts. Prescribed burns are an important tool to reduce the severity of wildfires. However, if undertaken during unfavourable meteorological conditions, they too have the capacity to trigger extreme air pollution events. The Australian state of New South Wales has increased the annual average area treated by prescribed burn activities by 45%, in order to limit wildfire activity. Prescribed burns need to be undertaken during meteorological conditions that allow the fuel load to burn, while still allowing the burn to remain under control. These conditions are similar to those that inhibit atmospheric dispersion, resulting in a fine balance between managing fire risk and managing ambient air pollution. During prescribed burns, the Sydney air shed can experience elevated particulate matter concentrations, especially fine particulates (PM2.5) that occasionally exceed national air quality standards. Using pollutant and meteorological data from sixteen monitoring stations in Sydney we used generalized additive model and CART analyses to profile the meteorological conditions influencing air quality during planned burns. The insights gained from this study will help improve prescribed burn scheduling in order to reduce the pollution risk to the community, while allowing fire agencies to conduct this important work.

  15. Infinite slab-shield dose calculations

    International Nuclear Information System (INIS)

    Russell, G.J.

    1989-01-01

    I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab

  16. Comparison and analysis of BNCT radiation dose between gold wire and JCDS measurement

    International Nuclear Information System (INIS)

    Kageji, T.; Mizobuchi, Y.; Nagahiro, S.; Nakagawa, Y.; Kumada, Hiroaki

    2006-01-01

    We compared and evaluated boron neutron capture therapy (BNCT) radiation dose between gold wire measurement and JAERI Computational Dosimetry System (JCDS). Gold wire analysis demonstrates the actual BNCT dose though it dose not reflect the real the maximum and minimum dose in tumor tissue. We can conclude that JCDS is precise and high-reliable dose planning system for BNCT. (author)

  17. Patient, Physician and Organizational Influences on Variation in Antipsychotic Prescribing Behavior.

    Science.gov (United States)

    Tang, Yan; Chang, Chung-Chou H; Lave, Judith R; Gellad, Walid F; Huskamp, Haiden A; Donohue, Julie M

    2016-03-01

    Physicians face the choice of multiple ingredients when prescribing drugs in many therapeutic categories. For conditions with considerable patient heterogeneity in treatment response, customizing treatment to individual patient needs and preferences may improve outcomes. To assess variation in the diversity of antipsychotic prescribing for mental health conditions, a necessary although not sufficient condition for personalizing treatment. To identify patient caseload, physician, and organizational factors associated with the diversity of antipsychotic prescribing. Using 2011 data from Pennsylvania's Medicaid program, IMS Health's HCOSTM database, and the AMA Masterfile, we identified 764 psychiatrists who prescribed antipsychotics to 10 patients. We constructed three physician-level measures of diversity/concentration of antipsychotic prescribing: number of ingredients prescribed, share of prescriptions for most preferred ingredient, and Herfindahl-Hirschman index (HHI). We used multiple membership linear mixed models to examine patient caseload, physician, and healthcare organizational predictors of physician concentration of antipsychotic prescribing. There was substantial variability in antipsychotic prescribing concentration among psychiatrists, with number of ingredients ranging from 2-17, share for most preferred ingredient from 16%-85%, and HHI from 1,088-7,270. On average, psychiatrist prescribing behavior was relatively diversified; however, 11% of psychiatrists wrote an average of 55% of their prescriptions for their most preferred ingredient. Female prescribers and those with smaller shares of disabled or serious mental illness patients had more concentrated prescribing behavior on average. Antipsychotic prescribing by individual psychiatrists in a large state Medicaid program varied substantially across psychiatrists. Our findings illustrate the importance of understanding physicians' prescribing behavior and indicate that even among specialties

  18. From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning

    International Nuclear Information System (INIS)

    Thieke, Christian; Bortfeld, Thomas; Niemierko, Andrzej; Nill, Simeon

    2003-01-01

    Optimization algorithms in inverse radiotherapy planning need information about the desired dose distribution. Usually the planner defines physical dose constraints for each structure of the treatment plan, either in form of minimum and maximum doses or as dose-volume constraints. The concept of equivalent uniform dose (EUD) was designed to describe dose distributions with a higher clinical relevance. In this paper, we present a method to consider the EUD as an optimization constraint by using the method of projections onto convex sets (POCS). In each iteration of the optimization loop, for the actual dose distribution of an organ that violates an EUD constraint a new dose distribution is calculated that satisfies the EUD constraint, leading to voxel-based physical dose constraints. The new dose distribution is found by projecting the current one onto the convex set of all dose distributions fulfilling the EUD constraint. The algorithm is easy to integrate into existing inverse planning systems, and it allows the planner to choose between physical and EUD constraints separately for each structure. A clinical case of a head and neck tumor is optimized using three different sets of constraints: physical constraints for all structures, physical constraints for the target and EUD constraints for the organs at risk, and EUD constraints for all structures. The results show that the POCS method converges stable and given EUD constraints are reached closely

  19. Contraceptive Provision to Adolescent Females Prescribed Teratogenic Medications.

    Science.gov (United States)

    Stancil, Stephani L; Miller, Melissa; Briggs, Holley; Lynch, Daryl; Goggin, Kathy; Kearns, Gregory

    2016-01-01

    Rates of adult women receiving contraceptive provision when simultaneously prescribed a known teratogen are alarmingly low. The prevalence of this behavior among pediatric providers and their adolescent patients is unknown. The objective of this study was to describe pediatric provider behaviors for prescribing teratogens concurrently with counseling, referral, and/or prescribing of contraception (collectively called contraceptive provision) in the adolescent population. A retrospective review was conducted examining visits in 2008-2012 by adolescents aged 14 to 25 years in which a known teratogen (US Food and Drug Administration pregnancy risk category D or X) was prescribed. The electronic medical records were queried for demographic information, evidence of contraceptive provision, and menstrual and sexual histories. The data were analyzed using standard statistical methods. Within 4172 clinic visits, 1694 females received 4506 prescriptions for teratogenic medications. The most commonly prescribed teratogens were topiramate, methotrexate, diazepam, isotretinoin, and enalapril. The subspecialties prescribing teratogens most frequently were neurology, hematology-oncology, and dermatology. Overall, contraceptive provision was documented in 28.6% of the visits. Whites versus nonwhites and older versus younger girls were more likely to receive contraceptive provision. The presence of a federal risk mitigation system for the teratogen also increased the likelihood of contraceptive provision. Our data demonstrate female adolescents prescribed teratogens receive inadequate contraception provision, which could increase their risk for negative pregnancy outcomes. Although the presence of a federal risk mitigation system appears to improve contraceptive provision, these systems are costly and, in some instances, difficult to implement. Efforts to improve provider practices are needed. Copyright © 2016 by the American Academy of Pediatrics.

  20. Validity of the Prescriber Information in the Danish National Prescription Registry

    DEFF Research Database (Denmark)

    Rasmussen, Lotte; Valentin, Julie; Gesser, Katarina Margareta

    2016-01-01

    The aim of this study was to measure the validity of the prescriber information recorded in the Danish National Prescription Registry (DNPR). The prescriber information recorded in the pharmacies' electronic dispensing system was considered to represent the prescriber information recorded...... in the DNPR. Further, the problem of validity of the prescriber information pertains only to non-electronic prescriptions, as these are manually entered into the dispensing system. The recorded prescriber information was thus validated against information from a total of 2,000 non-electronic prescriptions...... at five Danish community pharmacies. The validity of the recorded prescriber information was measured at the level of the individual prescriber and the prescriber type, respectively. The proportion of non-electronic prescriptions with incorrect registrations was 22.4% (95% Confidence Interval (CI): 20...

  1. Association between Pre-Operative Cefazolin Dose and Surgical Site Infection in Obese Patients.

    Science.gov (United States)

    Peppard, William J; Eberle, David G; Kugler, Nathan W; Mabrey, Danielle M; Weigelt, John A

    A fixed dose of cefazolin results in serum concentrations that decrease as body mass increases. Current national guidelines suggest a pre-operative cefazolin dose of two grams may be insufficient for patients ≥120 kg; thus a three gram dose is recommended. These recommendations, however, are based on pharmacokinetic rather than outcome data. We evaluate the efficacy of pre-operative cefazolin two gram and three gram doses as measured by the rate of surgical site infection (SSI). We conducted a retrospective review of adult patients ≥100 kg who were prescribed cefazolin as surgical prophylaxis between September 1, 2012 and May 31, 2013 at an academic medical center. Patients were excluded if cefazolin was prescribed but not administered, had a known infection at the site of surgery, or inappropriately received cefazolin prophylaxis based on surgical indication. The SSIs were identified by documentation of SSI in the medical record or findings consistent with the standard Centers for Disease Control and Prevention definition. Inpatient and outpatient records up to 90 days post-operative were reviewed for delayed SSI. Four hundred eighty-three surgical cases were identified in which pre-operative cefazolin was prescribed. Forty-seven patients were excluded leaving a total of 436 patients for final analysis: 152 in the cefazolin two gram group and 284 in the three gram group. Baseline demographics were similar between groups with a mean follow-up duration of 77 days for both groups. Unadjusted SSI rates were 7.2% and 7.4% (odds ratio [OR] 0.98, p = 0.95), for the two gram and three gram groups, respectively. When differences in follow-up between groups were considered and logistic regression was adjusted with propensity score, there remained no difference in SSI rates (OR 0.87, 95% confidence interval 0.36-2.06, p = 0.77). In otherwise similar obese surgical patients weighing ≥100 kg, the administration of a pre-operative cefazolin two gram dose is

  2. Stakeholder views on the impact of nurse prescribing on dermatology services.

    Science.gov (United States)

    Carey, Nicola; Stenner, Karen; Courtenay, Molly

    2010-02-01

    To explore stakeholder views on the impact of nurse prescribing on dermatology services. Nurse led care enhances the services that dermatology patients receive. Research indicates that care delivered by nurse prescribers can improve efficiency and access to medicines. There is no evidence exploring the impact of nurse prescribing on the configuration of dermatology services. Case study. A collective case study of 10 practice settings across England where nurses prescribed medicines for dermatology patients. A thematic analysis of semi-structured interview data collected during 2006 and 2007. Participants were qualified nurse prescribers, administrative staff, doctors and non-nurse prescribers. Nurse prescribing was reported to support and facilitate the modernisation of dermatology services. It enabled nurses to make effective use of their knowledge and skills, overcome delays in treatment and provide faster access to medicines. However several organisational issues restricted the success of the initiative. Nurse prescribing is successfully being used to support and deliver a range of services to dermatology patients. Stakeholders reported that both patients and staff had benefited by the adoption of this role by nurses. However issues over support and access to CPD and capacity of the workforce were identified as potential barriers which could affect the contribution of nurse prescribing to dermatology patients. Nurse prescribing contributes to the services provided to dermatology patients; Nurse supplementary prescribing contributes to the ability of dermatology nurse specialists to work in teams and prescribe complex medicines; Provision of adequate support and strategic planning are essential if the impact of nurse prescribing is to be fully realised.

  3. Prescribing errors in a Brazilian neonatal intensive care unit

    Directory of Open Access Journals (Sweden)

    Ana Paula Cezar Machado

    2015-12-01

    Full Text Available Abstract Pediatric patients, especially those admitted to the neonatal intensive care unit (ICU, are highly vulnerable to medication errors. This study aimed to measure the prescription error rate in a university hospital neonatal ICU and to identify susceptible patients, types of errors, and the medicines involved. The variables related to medicines prescribed were compared to the Neofax prescription protocol. The study enrolled 150 newborns and analyzed 489 prescription order forms, with 1,491 medication items, corresponding to 46 drugs. Prescription error rate was 43.5%. Errors were found in dosage, intervals, diluents, and infusion time, distributed across 7 therapeutic classes. Errors were more frequent in preterm newborns. Diluent and dosing were the most frequent sources of errors. The therapeutic classes most involved in errors were antimicrobial agents and drugs that act on the nervous and cardiovascular systems.

  4. Adjustable Maintenance Dosing with Budesonide/Formoterol Reduces Asthma Exacerbations Compared with Traditional Fixed Dosing: A Five-Month Multicentre Canadian Study

    Directory of Open Access Journals (Sweden)

    J Mark FitzGerlad

    2003-01-01

    Full Text Available BACKGROUND: Adjustable maintenance dosing with budesonide/formoterol in a single inhaler (Symbicort, AstraZeneca, Lund, Sweden may provide a convenient means of maintaining asthma control with the minimum effective medication level.

  5. Does non-medical prescribing make a difference to patients?

    Science.gov (United States)

    Carey, Nicola; Stenner, Karen

    This article examines the literature on non-medical prescribing to establish its impact on UK healthcare. It discusses how better access to medication through non-medical prescribing can improve patient safety and patient-centred care, and how nurse prescribing can help ensure quality of care in the NHS during the current financial crisis.

  6. Medication discussion between nurse prescribers and people with diabetes

    DEFF Research Database (Denmark)

    Sibley, Andrew; Latter, Sue; Richard, Claude

    2011-01-01

    Aim. This paper is a report of a study to identify the content of, and participation in, medicine discussion between nurse prescribers and people with diabetes in England. Background. Diabetes affects 246 million people worldwide and effective management of medicines is an essential component...... of successful disease control. There are now over 20,000 nurse independent prescribers in the UK, many of whom frequently prescribe for people with diabetes. With this responsibility comes a challenge to effectively communicate with patients about medicines. National guidelines on medicines communication have...... recently been issued, but the extent to which nurse prescribers are facilitating effective medicine-taking in diabetes remains unknown. Methods. A purposive sample of 20 nurse prescribers working with diabetes patients audio-recorded 59 of their routine consultations and a descriptive analysis...

  7. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-07-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (microg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r=0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r=0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA.

  8. Quantitative comparison of the results obtained by the multiple-dose guinea pig maximization test and the non-radioactive murine local lymph-node assay for various biocides

    International Nuclear Information System (INIS)

    Yamano, Tetsuo; Shimizu, Mitsuru; Noda, Tsutomu

    2005-01-01

    We compared the results of the multiple-dose guinea pig maximization test (GPMT) and the non-radioactive murine local lymph-node assay (LLNA) for various biocides. Thirteen out of 17 positive biocides in the GPMT gave positive results in the LLNA. In the GPMT, the minimum first induction doses ranged over four orders (0.00005-0.5%), while elicitation-threshold doses, which were evaluated using an optimally sensitized group of animals in the multiple-dose studies, ranged over five orders (0.00006-2.8%). In the LLNA, minimum induction doses ranged over more than three orders (0.01-30%). With respect to 13 biocides that were positive in both the GPMT and the LLNA, results were quantitatively compared. When compared after conversion to corresponding area doses (μg/cm), the minimum doses required to elicit skin reaction in guinea pigs were always lower than that for induction in mice with all biocides. Correlation between minimum induction doses from the GPMT and the LLNA seemed poor (r = 0.57), while that between minimum induction doses in the LLNA and elicitation-threshold doses in the GPMT was relatively good (r = 0.73). The results suggest the possibility to estimate human elicitation-threshold doses, which are definitely lacking in the process of risk assessment for skin-sensitizers, from the data of the LLNA

  9. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  10. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  11. Impact of generic substitution decision support on electronic prescribing behavior.

    Science.gov (United States)

    Stenner, Shane P; Chen, Qingxia; Johnson, Kevin B

    2010-01-01

    To evaluate the impact of generic substitution decision support on electronic (e-) prescribing of generic medications. The authors analyzed retrospective outpatient e-prescribing data from an academic medical center and affiliated network for July 1, 2005-September 30, 2008 using an interrupted time-series design to assess the rate of generic prescribing before and after implementing generic substitution decision support. To assess background secular trends, e-prescribing was compared with a concurrent random sample of hand-generated prescriptions. Proportion of generic medications prescribed before and after the intervention, evaluated over time, and compared with a sample of prescriptions generated without e-prescribing. The proportion of generic medication prescriptions increased from 32.1% to 54.2% after the intervention (22.1% increase, 95% CI 21.9% to 22.3%), with no diminution in magnitude of improvement post-intervention. In the concurrent control group, increases in proportion of generic prescriptions (29.3% to 31.4% to 37.4% in the pre-intervention, post-intervention, and end-of-study periods, respectively) were not commensurate with the intervention. There was a larger change in generic prescribing rates among authorized prescribers (24.6%) than nurses (18.5%; adjusted OR 1.38, 95% CI 1.17 to 1.63). Two years after the intervention, the proportion of generic prescribing remained significantly higher for e-prescriptions (58.1%; 95% CI 57.5% to 58.7%) than for hand-generated prescriptions ordered at the same time (37.4%; 95% CI 34.9% to 39.9%) (p<0.0001). Generic prescribing increased significantly in every specialty. Implementation of generic substitution decision support was associated with dramatic and sustained improvements in the rate of outpatient generic e-prescribing across all specialties.

  12. Nurse prescribing ethics and medical marketing.

    Science.gov (United States)

    Adams, J

    This article suggests that nurse prescribers require an awareness of key concepts in ethics, such as deontology and utilitarianism to reflect on current debates and contribute to them. The principles of biomedical ethics have also been influential in the development of professional codes of conduct. Attention is drawn to the importance of the Association of the British Pharmaceutical Industry's code of practice for the pharmaceutical industry in regulating marketing aimed at prescribers.

  13. Doses of Nearby Nature Simultaneously Associated with Multiple Health Benefits

    Directory of Open Access Journals (Sweden)

    Daniel T. C. Cox

    2017-02-01

    Full Text Available Exposure to nature provides a wide range of health benefits. A significant proportion of these are delivered close to home, because this offers an immediate and easily accessible opportunity for people to experience nature. However, there is limited information to guide recommendations on its management and appropriate use. We apply a nature dose-response framework to quantify the simultaneous association between exposure to nearby nature and multiple health benefits. We surveyed ca. 1000 respondents in Southern England, UK, to determine relationships between (a nature dose type, that is the frequency and duration (time spent in private green space and intensity (quantity of neighbourhood vegetation cover of nature exposure and (b health outcomes, including mental, physical and social health, physical behaviour and nature orientation. We then modelled dose-response relationships between dose type and self-reported depression. We demonstrate positive relationships between nature dose and mental and social health, increased physical activity and nature orientation. Dose-response analysis showed that lower levels of depression were associated with minimum thresholds of weekly nature dose. Nearby nature is associated with quantifiable health benefits, with potential for lowering the human and financial costs of ill health. Dose-response analysis has the potential to guide minimum and optimum recommendations on the management and use of nearby nature for preventative healthcare.

  14. Nurse prescriber-patient consultations: a case study in dermatology.

    Science.gov (United States)

    Courtenay, Molly; Carey, Nicola; Stenner, Karen

    2009-06-01

    This paper is a report of a study exploring the content and processes in consultations between nurse prescribers and patients with dermatological conditions. Communication skills, consultation time, information and follow-up are central to the treatment and management of patients with dermatological conditions. The contribution nurses make to the care of these patients has great potential. A multiple case study was conducted with 10 practice settings across England in which nurses prescribed medicines for patients with dermatological conditions. Data were collected between June 2006 and September 2007 using semi-structured interviews (n = 40), patient questionnaires (n = 165/200) and videotaped observations of nurse consultations (n = 40). Data analysis included thematic analysis, descriptive statistics, chi-square and non-parametric tests. Nurses believed that their holistic approach to assessment, combined with their prescribing knowledge, improved prescribing decisions. Listening and explanation of treatments were aspects of nurse communication that were rated highly by patients. Listening and dealing sensitively with emotions were also aspects of the videotaped consultations that were rated highly by assessors. Nurses were less consistent in providing information about medicines. Triangulated data from this study suggest that nurse prescribing enhances the care of patients with dermatological conditions through improved prescribing decisions. If patients are to be more involved in this decision-making, nurses must give them more information about their medicines. The benefits of prescribing were most evident in the practices of dermatology specialist nurses. Further evidence is required to identify whether prescribing by specialist nurses offers similar benefits in other therapeutic areas.

  15. Factor analysis improves the selection of prescribing indicators

    DEFF Research Database (Denmark)

    Rasmussen, Hanne Marie Skyggedal; Søndergaard, Jens; Sokolowski, Ineta

    2006-01-01

    OBJECTIVE: To test a method for improving the selection of indicators of general practitioners' prescribing. METHODS: We conducted a prescription database study including all 180 general practices in the County of Funen, Denmark, approximately 472,000 inhabitants. Principal factor analysis was us...... appropriate and inappropriate prescribing, as revealed by the correlation of the indicators in the first factor. CONCLUSION: Correlation and factor analysis is a feasible method that assists the selection of indicators and gives better insight into prescribing patterns....

  16. Changing doctor prescribing behaviour

    DEFF Research Database (Denmark)

    Gill, P.S.; Mäkelä, M.; Vermeulen, K.M.

    1999-01-01

    Collaboration on Effective Professional Practice. This register is kept up to date by searching the following databases for reports of relevant research: DHSS-DATA; EMBASE; MEDLINE; SIGLE; Resource Database in Continuing Medical Education (1975-1994), along with bibliographies of related topics, hand searching......The aim of this overview was to identify interventions that change doctor prescribing behaviour and to derive conclusions for practice and further research. Relevant studies (indicating prescribing as a behaviour change) were located from a database of studies maintained by the Cochrane...... of key journals and personal contact with content area experts. Randomised controlled trials and non-equivalent group designs with pre- and post-intervention measures were included. Outcome measures were those used by the study authors. For each study we determined whether these were positive, negative...

  17. Evaluation of IMRT plans for prostate treatment using energies of 6 MV and 15 MV; Avaliacao de planejamentos de IMRT para tratamento de prostata utilizando energias de 6 MV e 15 MV

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Lucas Francisco C.; Silva, Murilo C. da; Silveira, Paula J.; Flosi, Adriana A.; Boccaletti, Karina W., E-mail: mcollete@gmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Servico de Radioterapia

    2013-08-15

    This study aims to evaluate and compare radiotherapy plans with intensity-modulated radiation therapy (IMRT) for prostate cancer treatments optimized for photon energies of 6 MV and 15 MV. We retrospectively evaluated 29 patients with prostate cancer, planned with IMRT technique with prescribed dose of 78 Gy. The initial plan was done for the two photon energies, keeping the same optimization parameters and comparing maximum, minimum and modal PTV doses, conformity and homogeneity indexes, dose gradients, isodoses volumes of 30, 40, 50, 60, and 70 Gy, and the total number of monitor units. It was found that the plans are equivalent regarding higher isodose volumes, conformity and homogeneity indexes, maximum, minimum and modal PTV doses. However, for 6 MV plans there was a considerable increase in both number of monitor units and volume lower isodose volumes, especially the 30 Gy. (author)

  18. Evaluation of IMRT plans for prostate treatment using energies of 6 MV and 15 MV

    International Nuclear Information System (INIS)

    Guimaraes, Lucas Francisco C.; Silva, Murilo C. da; Silveira, Paula J.; Flosi, Adriana A.; Boccaletti, Karina W.

    2013-01-01

    This study aims to evaluate and compare radiotherapy plans with intensity-modulated radiation therapy (IMRT) for prostate cancer treatments optimized for photon energies of 6 MV and 15 MV. We retrospectively evaluated 29 patients with prostate cancer, planned with IMRT technique with prescribed dose of 78 Gy. The initial plan was done for the two photon energies, keeping the same optimization parameters and comparing maximum, minimum and modal PTV doses, conformity and homogeneity indexes, dose gradients, isodoses volumes of 30, 40, 50, 60, and 70 Gy, and the total number of monitor units. It was found that the plans are equivalent regarding higher isodose volumes, conformity and homogeneity indexes, maximum, minimum and modal PTV doses. However, for 6 MV plans there was a considerable increase in both number of monitor units and volume lower isodose volumes, especially the 30 Gy. (author)

  19. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Gopalakrishnan, M; Lee, P; Sathiaseelan, V [Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL (United States)

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

  20. SU-E-J-33: Cardiac Movement in Deep Inspiration Breath-Hold for Left-Breast Cancer Radiotherapy

    International Nuclear Information System (INIS)

    Kim, M; Lee, S; Suh, T

    2014-01-01

    Purpose: The present study was designed to investigate the displacement of heart using Deep Inspiration Breath Hold (DIBH) CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Methods: Treatment planning was performed on the computed tomography (CT) datasets of 20 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ≥ 95% of the prescribed dose and that the volume inside the CTV receiving > 107% of the prescribed dose should be minimized. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. Results: The maximum and minimum left-right (LR) displacements of heart were 8.9 mm and 3 mm, respectively. The heart moved > 4 mm in the LR direction in 17 of the 20 patients. The distances between the heart and left breast ranged from 8.02–17.68 mm (mean, 12.23 mm) and 7.85–12.98 mm (mean, 8.97 mm) with DIBH CT and FB CT, respectively. The maximum doses to the heart were 3115 cGy and 4652 cGy for the DIBH and FB CT dataset, respectively. Conclusion: The present study has demonstrated that the DIBH technique could help to reduce the risk of radiation dose-induced cardiac toxicity by using movement of cardiac; away from radiation field. The DIBH technique could be used in an actual treatment room for a few minutes and could effectively reduce the cardiac dose when used with a sub-device or image acquisition standard to maintain consistent respiratory motion

  1. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    O'Donnell, Brian D

    2009-07-01

    Ultrasound guidance facilitates precise needle and injectate placement, increasing axillary block success rates, reducing onset times, and permitting local anesthetic dose reduction. The minimum effective volume of local anesthetic in ultrasound-guided axillary brachial plexus block is unknown. The authors performed a study to estimate the minimum effective anesthetic volume of 2% lidocaine with 1:200,000 epinephrine (2% LidoEpi) in ultrasound-guided axillary brachial plexus block.

  2. Failure-probability driven dose painting

    International Nuclear Information System (INIS)

    Vogelius, Ivan R.; Håkansson, Katrin; Due, Anne K.; Aznar, Marianne C.; Kristensen, Claus A.; Rasmussen, Jacob; Specht, Lena; Berthelsen, Anne K.; Bentzen, Søren M.

    2013-01-01

    Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity

  3. Opioid Prescribing PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the July 2017 CDC Vital Signs report. Higher opioid prescribing puts patients at risk for addiction and overdose. Learn what can be done about this serious problem.

  4. Analysis of Out Door Patients' Prescriptions According to World Health Organization (WHO) Prescribing Indicators Among Private Hospitals in Western India.

    Science.gov (United States)

    Shelat, Prakash R; Kumbar, Shivaprasad Kalakappa

    2015-03-01

    Prescription is document through which doctor, patient and pharmacist are communicated. Many a times if these documents are not properly written or misinterpreted it can affect management of patients. WHO established prescribing indicators to analyse prescription and promoted rational use of drugs and better management of patients. To study the prescription pattern according to WHO prescribing indicators among private hospitals. The observational, prospective study carried out at different private hospitals at metro city in Western India to study the prescription pattern among private hospital. Study was conducted at different private hospitals of metro city. A total of 250 prescriptions of outdoor patients from various departments of private hospitals were collected for a period of three months (August to October) 2012 and evaluated. The study was analysed using Z-test. Patient details like age and gender was not written in all (100%) prescriptions. It was noticed that dose, direction of drug and duration of treatment was not completely written in 90%, 74% and 80% of prescriptions respectively. Abbreviations were used in all (100%) prescriptions. Doctor's medical registration number was mentioned in 0% prescriptions. Total 869 drugs were prescribed in 250 prescriptions. Average number of drug prescribed was 3.38±1.79 (Mean±SD). It was reported that Group II (3 to 4 encoutner) was significantly higher as compared to Group I (less than or equal to 2 encoutner) and Group III( more than four encounter). It was significantly (pprivate hospitals and antibiotics was commonly prescribed in private sector. Therefore, strict policy to good prescribing practice and strict antibiotic policy in outdoor patients are required to promote rational use of drugs.

  5. Dose calculations algorithm for narrow heavy charged-particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Barna, E A; Kappas, C [Department of Medical Physics, School of Medicine, University of Patras (Greece); Scarlat, F [National Institute for Laser and Plasma Physics, Bucharest (Romania)

    1999-12-31

    The dose distributional advantages of the heavy charged-particles can be fully exploited by using very efficient and accurate dose calculation algorithms, which can generate optimal three-dimensional scanning patterns. An inverse therapy planning algorithm for dynamically scanned, narrow heavy charged-particle beams is presented in this paper. The irradiation `start point` is defined at the distal end of the target volume, right-down, in a beam`s eye view. The peak-dose of the first elementary beam is set to be equal to the prescribed dose in the target volume, and is defined as the reference dose. The weighting factor of any Bragg-peak is determined by the residual dose at the point of irradiation, calculated as the difference between the reference dose and the cumulative dose delivered at that point of irradiation by all the previous Bragg-peaks. The final pattern consists of the weighted Bragg-peaks irradiation density. Dose distributions were computed using two different scanning steps equal to 0.5 mm, and 1 mm respectively. Very accurate and precise localized dose distributions, conform to the target volume, were obtained. (authors) 6 refs., 3 figs.

  6. Radiographic film: surface dose extrapolation techniques

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW; Currie, M.

    2004-01-01

    Full text: Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate 2 dimensional map of surface dose if required. Results have shown that surface % dose can be estimated within ±3% of parallel plate ionisation chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10cm, 20cmand 30cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. Corresponding parallel plate ionisation chamber measurement are 16%, 27% and 37% respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  7. Prescribing patterns in premenstrual syndrome

    Directory of Open Access Journals (Sweden)

    Jones Paul W

    2002-06-01

    Full Text Available Abstract Background Over 300 therapies have been proposed for premenstrual syndrome. To date there has been only one survey conducted in the UK of PMS treatments prescribed by GPs, a questionnaire-based study by the National Association of Premenstrual Syndrome in 1989. Since then, selective serotonin re-uptake inhibitors have been licensed for severe PMS/PMDD, and governmental recommendations to reduce the dosage of vitamin B6 (the first choice over-the-counter treatment for many women with PMS have been made. This study investigates the annual rates of diagnoses and prescribing patterns for premenstrual syndrome (1993–1998 within a computerised general practitioner database. Methods Retrospective survey of prescribing data for premenstrual syndrome between 1993–1998 using the General Practice Research Database for the West Midlands Region which contains information on 282,600 female patients Results Overall the proportion of women with a prescription-linked diagnosis of premenstrual syndrome has halved over the five years. Progestogens including progesterone were the most commonly recorded treatment for premenstrual syndrome during the whole study period accounting for over 40% of all prescriptions. Selective serotonin-reuptake inhibitors accounted for only 2% of the prescriptions in 1993 but rose to over 16% by 1998, becoming the second most commonly recorded treatment. Vitamin B6 accounted for 22% of the prescriptions in 1993 but dropped markedly between 1997 and 1998 to 11%. Conclusions This study shows a yearly decrease in the number of prescriptions linked to diagnoses for premenstrual syndrome. Progestogens including progesterone, is the most widely prescribed treatment for premenstrual syndrome despite the lack of evidence demonstrating their efficacy.

  8. Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

    International Nuclear Information System (INIS)

    Baldelli, P; Bravin, A; Maggio, C Di; Gennaro, G; Sarnelli, A; Taibi, A; Gambaccini, M

    2006-01-01

    Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml -1 and 1.34 mg ml -1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml -1 and 1.31 mg ml -1 . With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml -1 (8 mm diameter) and 5.75 mg ml -1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml -1 (8 mm diameter) and 1.57 mg ml -1 (5 mm diameter)

  9. Off-label prescribing patterns of antiemetics in children: a multicenter study in Italy.

    Science.gov (United States)

    Zanon, Davide; Gallelli, Luca; Rovere, Francesca; Paparazzo, Rossella; Maximova, Natalia; Lazzerini, Marzia; Reale, Antonio; Corsetti, Tiziana; Renna, Salvatore; Emanueli, Tullia; Mannelli, Francesco; Manteghetti, Francesco; Da Dalt, Liviana; Palleria, Caterina; Banchieri, Nicola; Urbino, Antonio; Miglietta, Mario; Cardoni, Giovanni; Pompilio, Adriana; Arrighini, Alberto; Lazzari, Clara; Messi, Gianni

    2013-03-01

    Acute gastroenteritis (AG) represents both the main cause of acute vomiting in children under 3 years old and a major cause of access to the emergency department. Even if several drugs may be able to reduce the emesis, the pharmacological treatment of vomiting in children remains a controversial issue, and several drugs are prescribed outside their authorized drug label with respect dosage, age, indication, or route of administration and are named as off-label. The aim of present study was to assess the off-label use of antiemetic drugs in patients less than 18 years with vomiting related to AG. This study was carried out in eight pediatric emergency departments in Italy. The following data were obtained crossing the pharmacy distribution records with emergency departments' patient data: sex and age of the patients and detailed information for each drug used (indication, dose, frequency, and route of administration). We recorded that antiemetic drugs were prescribed in every year, particularly in children up to 2 years old, and compared with both literature data and data sheet; 30 % of the administered antiemetics were used off-label. In particular, domperidone was the only antiemetic used labeled for AG treatment in pediatric patients, while metoclopramide and ondansetron have been off-label for both age and indications (i.e., AG treatment). In conclusion, we documented an off-label use of antiemetics in children, and this could represents a problem of safety for the patient and a legal risk for the prescribing physician if patients have an unwanted or bad outcome from treatment.

  10. Dose-rate effects in synchronous mammalian cells in culture. II. A comparison of the life cycle of HeLa cells during continuous irradiation or multiple-dose fractionation

    International Nuclear Information System (INIS)

    Mitchell, J.B.; Bedford, J.S.

    1977-01-01

    The life cycle of synchronized S3 HeLa cells was examined during continuous irradiation at a dose rate of approximately 37 rad/hr and during multiple dose fractionation schedules of the same average dose rate (total dose / overall time = average dose rate). For all regimes given at this dose rate the effects on the life cyclee were similar. Cells progressed through G1 and S without appreciable delay and experienced a minimum G2 delay of about 10 hr. Cells eventually entered mitosis but virtually none were able to complete a successful division

  11. Dose distribution and clinical response of glioblastoma treated with boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)], E-mail: mhide-m@gk9.so-net.ne.jp; Yamamoto, T. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Kumada, H. [Japan Atomic Energy Agency, Shirakatashirane 2-4, Tokai (Japan); Nakai, K.; Shirakawa, M.; Tsurubuchi, T.; Matsumura, A. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)

    2009-07-15

    The dose distribution and failure pattern after treatment with the external beam boron neutron capture therapy (BNCT) protocol were retrospectively analyzed. BSH (5 g/body) and BPA (250 mg/kg) based BNCT was performed in eight patients with newly diagnosed glioblastoma. The gross tumor volume (GTV) and clinical target volume (CTV)-1 were defined as the residual gadolinium-enhancing volume. CTV-2 and CTV-3 were defined as GTV plus a margin of 2 and 3 cm, respectively. As additional photon irradiation, a total X-ray dose of 30 Gy was given to the T2 high intensity area on MRI. Five of the eight patients were alive at analysis for a mean follow-up time of 20.3 months. The post-operative median survival time of the eight patients was 27.9 months (95% CI=21.0-34.8). The minimum tumor dose of GTV, CTV-2, and CTV-3 averaged 29.8{+-}9.9, 15.1{+-}5.4, and 12.4{+-}2.9 Gy, respectively. The minimum tumor non-boron dose of GTV, CTV-2, and CTV-3 averaged 2.0{+-}0.5, 1.3{+-}0.3, and 1.1{+-}0.2 Gy, respectively. The maximum normal brain dose, skin dose, and average brain dose were 11.4{+-}1.5, 9.6{+-}1.4, and 3.1{+-}0.4 Gy, respectively. The mean minimum dose at the failure site in cases of in-field recurrence (IR) and out-field recurrence (OR) was 26.3{+-}16.7 and 14.9 GyEq, respectively. The calculated doses at the failure site were at least equal to the tumor control doses which were previously reported. We speculate that the failure pattern was related to an inadequate distribution of boron-10. Further improvement of the microdistribution of boron compounds is expected, and may improve the tumor control by BNCT.

  12. Sorafenib prescribed by gastroenterologists and hepatologists for hepatocellular carcinoma

    Science.gov (United States)

    Kaplan, David E.; Mehta, Rajni; D’Addeo, Kathryn; Valderrama, Adriana; Taddei, Tamar H.

    2018-01-01

    Abstract Sorafenib is the only Food and Drug Administration (FDA)-approved first-line therapy shown to have survival benefit for patients with advanced hepatocellular carcinoma (HCC). Patients with advanced HCC are often but not exclusively transferred from non-oncologists to oncologists to initiate systemic therapy. The objective of this study was to assess whether sorafenib prescribing by non-oncologists has any impact on utilization, adverse effects, cost or outcome. This was a retrospective cohort study utilizing data from patients prescribed sorafenib for HCC within Veterans Health Administration hospitals with 100% chart abstraction to confirm HCC diagnosis, identify prescribing provider specialty (oncology versus gastroenterology/hepatology), and obtain data required for cancer staging by the Barcelona Clinic Liver Cancer (BCLC) system. The primary outcome was overall survival from the time of sorafenib prescription. A total of 4903 patients who prescribed sorafenib for HCC were identified, for whom 340 patients (6.9%) were prescribed drug by a non-oncologist (Onc). BCLC Stage, age, Child–Turcotte–Pugh score, and comorbidity indices were similar between patients prescribed sorafenib by oncologists and non-oncologists. Oncologists more often discontinued sorafenib due to progression, whereas non-oncologists were more likely to continue sorafenib until death resulting in greater pill utilization and cost. Overall survival in both unadjusted and multivariable models showed no significant impact of prescriber type on survival (222 vs 217 days, P = .96), confirmed with propensity-matched subcohorts. Similar survival outcomes were observed for patients with HCC prescribed sorafenib by non-oncologists and oncologists, suggesting that non-oncologists with expertise in the management of HCC can safely and effectively administer sorafenib. PMID:29369224

  13. Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer

    International Nuclear Information System (INIS)

    Chung, Heeteak; Jin, Hosang; Dempsey, James F.; Liu, Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Despite much development, there remains dosimetric uncertainty in the surface and build-up regions in intensity-modulated radiation therapy treatment plans for head and neck cancers. Experiments were performed to determine the dosimetric discrepancies in the surface and build-up region between the treatment planning system (TPS) prediction and experimental measurement using radiochromic film. A head and neck compression film phantom was constructed from two semicylindrical solid water slabs. Treatment plans were generated using two commercial TPSs (PINNACLE3 and CORVUS) for two cases, one with a shallow (∼0.5 cm depth) target and another with a deep (∼6 cm depth) target. The plans were evaluated for a 54 Gy prescribed dose. For each case, two pieces of radiochromic film were used for dose measurement. A small piece of film strip was placed on the surface and another was inserted within the phantom. Overall, both TPSs showed good agreement with the measurement. For the shallow target case, the dose differences were within ±300 cGy (5.6% with respect to the prescribed dose) for PINNACLE3 and ±240 cGy (4.4%) for CORVUS in 90% of the region of interest. For the deep target case, the dose differences were ±350 (6.5%) for PINNACLE3 and ±260 cGy (4.8%) for CORVUS in 90% of the region of interest. However, it was found that there were significant discrepancies from the surface to about 0.2 cm in depth for both the shallow and deep target cases. It was concluded that both TPSs overestimated the surface dose for both shallow and deep target cases. The amount of overestimation ranges from 400 to 1000 cGy (∼7.4% to 18.5% with respect to the prescribed dose, 5400 cGy)

  14. Antimicrobial prescribing behaviour in dogs and cats by Belgian veterinarians.

    Science.gov (United States)

    Van Cleven, Alexia; Sarrazin, Steven; de Rooster, Hilde; Paepe, Dominique; Van der Meeren, Sofie; Dewulf, Jeroen

    2018-03-17

    The objective of this study is to survey general prescribing behaviour by Belgian companion animal veterinarians and to assess agreement of these practices with current treatment guidelines. Therefore an online survey was administered with five realistic and frequently occurring first-line cases to primary-care veterinary practitioners. For each case a predefined pattern of questions were asked about whether or not they would prescribe antimicrobials, if they would prescribe a non-antimicrobial treatment and if they would perform additional diagnostic steps. The responses were compared with recommendations in national guidelines and recent literature. The overall most prescribed antimicrobials were potentiated amoxicillin (43.0 per cent), fluoroquinolones (14.7 per cent), third-generation and fourth-generation cephalosporins (10.9 per cent) and tetracyclines (10.9 per cent). Only 48.3 per cent of the veterinarians complied with the guidelines in nearly all of the clinical scenarios (ie, prescribing antimicrobials when indicated, not prescribing antimicrobials when it is not indicated). Moreover, when prescribing highest priority critically important antimicrobials, susceptibility testing on bacterial cultures was performed in only 12.4 per cent of the prescriptions. The results showed that the prescribing behaviour of antimicrobial compounds by primary-care veterinary practitioners in dogs and cats is often not in agreement with national guidelines. Focus in improvement of this prescribing behaviour should be on performing the appropriate diagnostic steps and decreasing the use of highest priority critically important antimicrobials. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Hospital staff views of prescribing and discharge communication before and after electronic prescribing system implementation.

    Science.gov (United States)

    Mills, Pamela Ruth; Weidmann, Anita Elaine; Stewart, Derek

    2017-12-01

    Background Electronic prescribing system implementation is recommended to improve patient safety and general practitioner's discharge information communication. There is a paucity of information about hospital staff perspectives before and after system implementation. Objective To explore hospital staff views regarding prescribing and discharge communication systems before and after hospital electronic prescribing and medicines administration (HEPMA) system implementation. Setting A 560 bed United Kingdom district general hospital. Methods Semi-structured face-to-face qualitative interviews with a purposive sample of hospital staff involved in the prescribing and discharge communication process. Interviews transcribed verbatim and coded using the Framework Approach. Behavioural aspects mapped to Theoretical Domains Framework (TDF) to highlight associated behavioural change determinants. Main outcome measure Staff perceptions before and after implementation. Results Nineteen hospital staff (consultant doctors, junior doctors, pharmacists and advanced nurse practitioners) participated before and after implementation. Pre-implementation main themes were inpatient chart and discharge letter design and discharge communication process with issues of illegible and inaccurate information. Improved safety was anticipated after implementation. Post-implementation themes were improved inpatient chart clarity and discharge letter quality. TDF domains relevant to staff behavioural determinants preimplementation were knowledge (task or environment); skills (competence); social/professional roles and identity; beliefs about capabilities; environmental context and resources (including incidents). An additional two were relevant post-implementation: social influences and behavioural regulation (including self-monitoring). Participants described challenges and patient safety concerns pre-implementation which were mostly resolved post-implementation. Conclusion HEPMA implementation

  16. Quality Improvement Initiative to Decrease Variability of Emergency Physician Opioid Analgesic Prescribing

    Directory of Open Access Journals (Sweden)

    John H. Burton

    2016-05-01

    Full Text Available Introduction: Addressing pain is a crucial aspect of emergency medicine. Prescription opioids are commonly prescribed for moderate to severe pain in the emergency department (ED; unfortunately, prescribing practices are variable. High variability of opioid prescribing decisions suggests a lack of consensus and an opportunity to improve care. This quality improvement (QI initiative aimed to reduce variability in ED opioid analgesic prescribing. Methods: We evaluated the impact of a three-part QI initiative on ED opioid prescribing by physicians at seven sites. Stage 1: Retrospective baseline period (nine months. Stage 2: Physicians were informed that opioid prescribing information would be prospectively collected and feedback on their prescribing and that of the group would be shared at the end of the stage (three months. Stage 3: After physicians received their individual opioid prescribing data with blinded comparison to the group means (from Stage 2 they were informed that individual prescribing data would be unblinded and shared with the group after three months. The primary outcome was variability of the standard error of the mean and standard deviation of the opioid prescribing rate (defined as number of patients discharged with an opioid divided by total number of discharges for each provider. Secondary observations included mean quantity of pills per opioid prescription, and overall frequency of opioid prescribing. Results: The study group included 47 physicians with 149,884 ED patient encounters. The variability in prescribing decreased through each stage of the initiative as represented by the distributions for the opioid prescribing rate: Stage 1 mean 20%; Stage 2 mean 13% (46% reduction, p<0.01, and Stage 3 mean 8% (60% reduction, p<0.01. The mean quantity of pills prescribed per prescription was 16 pills in Stage 1, 14 pills in Stage 2 (18% reduction, p<0.01, and 13 pills in Stage 3 (18% reduction, p<0.01. The group mean

  17. On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function

    International Nuclear Information System (INIS)

    Bowen, Stephen R; Bentzen, Soeren M; Jeraj, Robert; Flynn, Ryan T

    2009-01-01

    Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation that maps the image data intensities to prescribed doses. However, the functional form of this transformation is currently unknown. An investigation into the sensitivity of optimized dose distributions resulting from several possible prescription functions was conducted. Transformations between the radiotracer activity concentrations from Cu-ATSM PET images, as a surrogate of tumour hypoxia, and dose prescriptions were implemented to yield weighted distributions of prescribed dose boosts in high uptake regions. Dose escalation was constrained to reflect clinically realistic whole tumour doses and constant normal tissue doses. Optimized heterogeneous dose distributions were found by minimizing a voxel-by-voxel quadratic objective function in which all tumour voxels were given equal weight. Prescriptions based on a polynomial mapping function were found to be least constraining on their optimized plans, while prescriptions based on a sigmoid mapping function were the most demanding to deliver. A prescription formalism that fixed integral dose was less sensitive to errors in the choice of the mapping function than one that boosted integral dose. Integral doses to normal tissue and critical structures were insensitive to the shape of the prescription function. Planned target dose conformity improved with smaller beamlet dimensions until the inherent spatial resolution of the functional image was matched. Clinical implementation of dose painting depends on advances in absolute quantification of functional images and improvements in delivery techniques over smaller spatial scales.

  18. Benefits of nurse prescribing for patients in pain: nurses' views.

    Science.gov (United States)

    Stenner, Karen; Courtenay, Molly

    2008-07-01

    This paper is a report of a study to explore nurses' views on the benefits of adopting the role of prescribing for patients with acute and chronic pain. It was envisioned that the advent of nurse prescribing would be beneficial to the efficiency and effectiveness of the United Kingdom National Health Service. Research to date does indeed indicate that nurse prescribing can be beneficial to patients, nurses and the health service in general. Despite the expansion of nurse prescribing, there is little evidence of its impact according to nurses working in specialist areas, such as with patients in acute and chronic pain. Interviews were conducted during 2006 and 2007 with 26 nurses qualified to prescribe medicines for patients in acute and chronic pain. This was a qualitative study and a thematic analysis was conducted. Nurses reported a number of benefits, including faster access to treatment, improved quality of care, more appropriate prescribing of medication, improved safety, improved relations and communication with patients, greater efficiency and cost effectiveness. Nurses benefited from increased job satisfaction, credibility with patients and healthcare professionals and also gained knowledge through prescribing. There is potential for the benefits of nurse prescribing to be expanded beyond the United Kingdom in settings where nurses hold similar roles in the treatment of pain, although further research using a wider range of research methods is recommended to substantiate these findings.

  19. Considerations on absorbed dose estimates based on different β-dose point kernels in internal dosimetry

    International Nuclear Information System (INIS)

    Uchida, Isao; Yamada, Yasuhiko; Yamashita, Takashi; Okigaki, Shigeyasu; Oyamada, Hiyoshimaru; Ito, Akira.

    1995-01-01

    In radiotherapy with radiopharmaceuticals, more accurate estimates of the three-dimensional (3-D) distribution of absorbed dose is important in specifying the activity to be administered to patients to deliver a prescribed absorbed dose to target volumes without exceeding the toxicity limit of normal tissues in the body. A calculation algorithm for the purpose has already been developed by the authors. An accurate 3-D distribution of absorbed dose based on the algorithm is given by convolution of the 3-D dose matrix for a unit cubic voxel containing unit cumulated activity, which is obtained by transforming a dose point kernel into a 3-D cubic dose matrix, with the 3-D cumulated activity distribution given by the same voxel size. However, beta-dose point kernels affecting accurate estimates of the 3-D absorbed dose distribution have been different among the investigators. The purpose of this study is to elucidate how different beta-dose point kernels in water influence on the estimates of the absorbed dose distribution due to the dose point kernel convolution method by the authors. Computer simulations were performed using the MIRD thyroid and lung phantoms under assumption of uniform activity distribution of 32 P. Using beta-dose point kernels derived from Monte Carlo simulations (EGS-4 or ACCEPT computer code), the differences among their point kernels gave little differences for the mean and maximum absorbed dose estimates for the MIRD phantoms used. In the estimates of mean and maximum absorbed doses calculated using different cubic voxel sizes (4x4x4 mm and 8x8x8 mm) for the MIRD thyroid phantom, the maximum absorbed doses for the 4x4x4 mm-voxel were estimated approximately 7% greater than the cases of the 8x8x8 mm-voxel. They were found in every beta-dose point kernel used in this study. On the other hand, the percentage difference of the mean absorbed doses in the both voxel sizes for each beta-dose point kernel was less than approximately 0.6%. (author)

  20. Electronic prescribing in pediatrics: toward safer and more effective medication management.

    Science.gov (United States)

    Johnson, Kevin B; Lehmann, Christoph U

    2013-04-01

    This technical report discusses recent advances in electronic prescribing (e-prescribing) systems, including the evidence base supporting their limitations and potential benefits. Specifically, this report acknowledges that there are limited but positive pediatric data supporting the role of e-prescribing in mitigating medication errors, improving communication with dispensing pharmacists, and improving medication adherence. On the basis of these data and on the basis of federal statutes that provide incentives for the use of e-prescribing systems, the American Academy of Pediatrics recommends the adoption of e-prescribing systems with pediatric functionality. This report supports the accompanying policy statement from the American Academy of Pediatrics recommending the adoption of e-prescribing by pediatric health care providers.

  1. Bladder accumulated dose in image-guided high-dose-rate brachytherapy for locally advanced cervical cancer and its relation to urinary toxicity

    Science.gov (United States)

    Zakariaee, Roja; Hamarneh, Ghassan; Brown, Colin J.; Gaudet, Marc; Aquino-Parsons, Christina; Spadinger, Ingrid

    2016-12-01

    The purpose of this study was to estimate locally accumulated dose to the bladder in multi-fraction high-dose-date (HDR) image-guided intracavitary brachytherapy (IG-ICBT) for cervical cancer, and study the locally-accumulated dose parameters as predictors of late urinary toxicity. A retrospective study of 60 cervical cancer patients who received five HDR IG-ICBT sessions was performed. The bladder outer and inner surfaces were segmented for all sessions and a bladder-wall contour point-set was created in MATLAB. The bladder-wall point-sets for each patient were registered using a deformable point-set registration toolbox called coherent point drift (CPD), and the fraction doses were accumulated. Various dosimetric and volumetric parameters were calculated using the registered doses, including r{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} (minimum dose to the most exposed n-cm3 volume of bladder wall), r V n Gy (wall volume receiving at least m Gy), and r\\text{EQD}{{2}n \\text{c{{\\text{m}}\\text{3}}}} (minimum equivalent biologically weighted dose to the most exposed n-cm3 of bladder wall), where n  =  1/2/5/10 and m  =  3/5/10. Minimum dose to contiguous 1 and 2 cm3 hot-spot volumes was also calculated. The unregistered dose volume histogram (DVH)-summed equivalent of r{{\\text{D}}n \\text{c{{\\text{m}}3}}} and r\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} parameters (i.e. s{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} and s\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} ) were determined for comparison. Late urinary toxicity was assessed using the LENT-SOMA scale, with toxicity Grade 0-1 categorized as Controls and Grade 2-4 as Cases. A two-sample t-test was used to identify the differences between the means of Control and Case groups for all parameters. A binomial logistic regression was also performed between the registered dose parameters and toxicity grouping. Seventeen patients were in the Case and 43 patients in the Control group. Contiguous

  2. Characteristics of prescribers whose patients shop for opioids: results from a cohort study.

    Science.gov (United States)

    Cepeda, M Soledad; Fife, Daniel; Berlin, Jesse A; Mastrogiovanni, Gregory; Yuan, Yingli

    2012-01-01

    Little is known about the prevalence of opioid shoppers in clinical practices and the relation between prescriber characteristics and the risk of having opioid shoppers. Describe the prevalence of opioid shoppers in prescribers' practices. Assess the relation between prescribers' characteristics and patient opioid shopping behavior. Retrospective cohort study using a large US retail prescription database. Patients with ≥1 opioid dispensing were followed 18 months. These patients' prescribers are the focus of the study. A patient was a "shopper" if he or she had opioid prescriptions written by ≥1 prescriber with ≥1 day of overlap filled at ≥3 pharmacies and a "heavy shopper" if he or she had ≥5 shopping episodes. The proportions of shoppers by prescriber and the proportion of prescribers with ≥1 shopper or heavy shopper were calculated. Among 858,290 opioid prescribers, most (87 percent) had no shoppers and 98 percent had no heavy shoppers. Prescribers who were aged 70-79 years, male, or who prescribed schedule II opioids had an increased likelihood of having shoppers. As the number of patients for whom a prescriber prescribed opioids increased, the proportion of shoppers also increased. Prescribers with 66 or more patients receiving opioids, who represented 25 percent of prescribers, prescribed for 82 percent of all shoppers. The great majority of opioid prescribers appear to have no shoppers in their practice. Any educational program will be more cost effective if targeted to prescribers of schedule II opioids with a large volume of patients requiring opioids.

  3. Antibiotics for URTI and UTI -- prescribing in Malaysian primary care settings.

    Science.gov (United States)

    Teng, Cheong Lieng; Tong, Seng Fah; Khoo, Ee Ming; Lee, Verna; Zailinawati, Abu Hassan; Mimi, Omar; Chen, Wei Seng; Nordin, Salleh

    2011-05-01

    Overprescription of antibiotics is a continuing problem in primary care. This study aims to assess the antibiotic prescribing rates and antibiotic choices for upper respiratory tract infections (URTI) and urinary tract infections (UTI) in Malaysian primary care. Antibiotic prescribing data for URTI and UTI was extracted from a morbidity survey of randomly selected primary care clinics in Malaysia. Analysis was performed of 1,163 URTI and 105 UTI encounters. Antibiotic prescribing rates for URTI and UTI were 33.8% and 57.1% respectively. Antibiotic prescribing rates were higher in private clinics compared to public clinics for URTI, but not for UTI. In URTI encounters, the majority of antibiotics prescribed were penicillins and macrolides, but penicillin V was notably underused. In UTI encounters, the antibiotics prescribed were predominantly penicillins or cotrimoxazole. Greater effort is needed to bring about evidence based antibiotic prescribing in Malaysian primary care, especially for URTIs in private clinics.

  4. Do Minimum Wages Fight Poverty?

    OpenAIRE

    David Neumark; William Wascher

    1997-01-01

    The primary goal of a national minimum wage floor is to raise the incomes of poor or near-poor families with members in the work force. However, estimates of employment effects of minimum wages tell us little about whether minimum wages are can achieve this goal; even if the disemployment effects of minimum wages are modest, minimum wage increases could result in net income losses for poor families. We present evidence on the effects of minimum wages on family incomes from matched March CPS s...

  5. The pharmacist as prescriber: a discourse analysis of newspaper media in Canada.

    Science.gov (United States)

    Schindel, Theresa J; Given, Lisa M

    2013-01-01

    Legislation to expand the scope of practice for pharmacists to include authority to independently prescribe medications in Alberta, Canada was announced in 2006 and enacted in April 2007. To date, very little research has explored public views of pharmacist prescribing. This study analyzes newspaper media coverage of pharmacist prescribing 1 year before and 2 years after prescribing was implemented. News items related to pharmacist prescribing were retrieved from 2 national, Canadian newspapers and 5 local newspapers in Alberta over a 3-year period after the announcement of pharmacist prescribing. A purposive sample of 66 texts including news items, editorials, and letters were retrieved electronically from 2 databases, Newscan and Canadian Newsstand. This study uses social positioning theory as a lens for analyzing the discourse of pharmacist prescribing. The results demonstrate a binary positioning of the debate on pharmacist prescribing rights. Using social positioning theory as a lens for analysis, the results illustrate self- and other-positioning of pharmacists' expected roles as prescribers. Themes related to the discourse on pharmacist prescribing include qualifications, diagnosis, patient safety, physician support, and conflict of interest. Media representations of pharmacist prescribing point to polarized views that may serve to shape public, pharmacist, physician, and others' opinions of the issue. Multiple and contradictory views of pharmacist prescribing coexist. Pharmacists and pharmacy organizations are challenged to bring clarity and consistency about pharmacist prescribing to better serve the public interest in understanding options for health care services. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. The differences in the incidence of diabetes mellitus and prediabetes according to the type of HMG-CoA reductase inhibitors prescribed in Korean patients.

    Science.gov (United States)

    Kim, Tong Min; Kim, Hyunah; Jeong, Yoo Jin; Baik, Sun Jung; Yang, So Jung; Lee, Seung-Hwan; Cho, Jae-Hyoung; Lee, Hyunyong; Yim, Hyeon Woo; Choi, In Young; Yoon, Kun-Ho; Kim, Hun-Sung

    2017-10-01

    Very few studies conducted in Korea have investigated the relationship between statins and the incidence of diabetes. Therefore, we analyzed the progression from normal blood glucose to prediabetes and then to diabetes mellitus (DM) according to the type, intensity, and dose of statin prescribed. Data of patients who were first prescribed statins between 2009 and 2011 were extracted from electronic medical records. Patients with normal blood glucose or prediabetes were observed for 4 years after initiation of statin therapy. A total of 2890 patients were included in our study and analyzed on the basis of the first statin they were prescribed. The incidence rate of DM in patients with prediabetes was 1.72 times that of patients with normal glucose levels (odds ratio = 1.72, 95% confidence interval = 1.41-2.10, P prediabetes, the incidence rate of prediabetes was significantly lower in patients prescribed pitavastatin (odds ratio = 0.62, 95% confidence interval = 0.40-0.96, P = .031) compared to that in patients prescribed atorvastatin. Regarding the progression from normal blood glucose or prediabetes to DM, there were no significant differences among all statins. Lower DM incidence in patients prescribed pitavastatin appears to be primarily because of the lower rate of progression from normal blood glucose to prediabetes. These findings indicate that avoiding statins because of DM risk is unjustified and that clinicians should prescribe statins from the appropriate potency group. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Inappropriate prescribing and prescribing omissions among drug-related problems using STOPP-START criteria

    NARCIS (Netherlands)

    Verdoorn, M.A.; Kwint, H.-F.; Faber, A.; L. Bouvy, M.

    2013-01-01

    Background and objectives: Medication review has been suggested as a way to prevent drug related problems (DRPs). Screening tools have been formulated to identify potentially inappropriate medicines (PIMs) and potential prescribing omissions (PPOs) respectively called Screening Tool of Older

  8. The Adjoint Method for The Optimization of Brachytherapy and Radiotherapy Patient Treatment Planning Procedures Using Monte Carlo Calculations

    International Nuclear Information System (INIS)

    Henderson, D.L.; Yoo, S.; Kowalok, M.; Mackie, T.R.; Thomadsen, B.R.

    2001-01-01

    The goal of this project is to investigate the use of the adjoint method, commonly used in the reactor physics community, for the optimization of radiation therapy patient treatment plans. Two different types of radiation therapy are being examined, interstitial brachytherapy and radiotherapy. In brachytherapy radioactive sources are surgically implanted within the diseased organ such as the prostate to treat the cancerous tissue. With radiotherapy, the x-ray source is usually located at a distance of about 1-meter from the patient and focused on the treatment area. For brachytherapy the optimization phase of the treatment plan consists of determining the optimal placement of the radioactive sources, which delivers the prescribed dose to the disease tissue while simultaneously sparing (reducing) the dose to sensitive tissue and organs. For external beam radiation therapy the optimization phase of the treatment plan consists of determining the optimal direction and intensity of beam, which provides complete coverage of the tumor region with the prescribed dose while simultaneously avoiding sensitive tissue areas. For both therapy methods, the optimal treatment plan is one in which the diseased tissue has been treated with the prescribed dose and dose to the sensitive tissue and organs has been kept to a minimum

  9. Information about radiation dose and risks in connection with radiological examinations: what patients would like to know

    International Nuclear Information System (INIS)

    Ukkola, Leila; Oikarinen, Heljae; Haapea, Marianne; Tervonen, Osmo; Henner, Anja; Honkanen, Hilkka

    2016-01-01

    To find out patients' wishes for the content and sources of the information concerning radiological procedures. A questionnaire providing quantitative and qualitative data was prepared. It comprised general information, dose and risks of radiation, and source of information. Two tables demonstrating different options to indicate the dose or risks were also provided. Patients could give one or many votes. Altogether, 147 patients (18-85 years) were interviewed after different radiological examinations using these devices. 95 % (139/147) of the patients wished for dose and risk information. Symbols (78/182 votes) and verbal scale (56/182) were preferred to reveal the dose, while verbal (83/164) and numerical scale (55/164) on the risk of fatal cancer were preferred to indicate the risks. Wishes concerning the course, options and purpose of the examination were also expressed. Prescriber (3.9 on a scale 1-5), information letter (3.8) and radiographer (3.3) were the preferred sources. Patients aged 66-85 years were reluctant to choose electronic channels. Apart from general information, patients wish for dose and risk information in connection with radiological examinations. The majority preferred symbols to indicate dose and verbal scales to indicate risks, and the preferred source of information was the prescriber or information letter. (orig.)

  10. A 5-year retrospective audit of prescribing by a critical care outreach team.

    Science.gov (United States)

    Wilson, Mark

    2018-05-01

    UK prescribing legislation changes made in 2006 and 2012 enabled appropriately qualified nurses to prescribe any licensed medication, and all controlled drugs in schedule 2-5 of the Misuse of Drugs Regulations 2001, for any medical condition within their clinical competence. Critical Care Outreach nurses who are independent nurse prescribers are ideally placed to ensure that acutely ill patients receive treatment without delay. The perceived challenge was how Critical Care Outreach nurses would be able to safely prescribe for a diverse patient group. This study informs this developing area of nurse prescribing in critical care practice. The aims of the audit were to: identify which medications were prescribed; develop a critical care outreach formulary; identify the frequency, timing and number of prescribing decisions being made; identify if prescribing practice changed over the years and provide information for our continuing professional development. This article reports on data collected from a 5-year retrospective audit; of prescribing activity undertaken by nine independent nurse prescribers working in a 24/7 Critical Care Outreach team of a 600-bedded district general hospital in the UK. In total, 8216 medication items were prescribed, with an average of 2·6 prescribed per shift. The most commonly prescribed items were intravenous fluids and analgesia, which were mostly prescribed at night and weekends. The audit has shown that Critical Care Outreach nurse prescribing is feasible in a whole hospital patient population. The majority of prescribing occurred after 16:00 and at night. Further research would be beneficial, particularly looking at patient outcomes following reviews from prescribing critical care outreach nurses. The audit is one of the only long-term studies that describes prescribing practice in Critical Care Outreach teams in the UK. © 2017 British Association of Critical Care Nurses.

  11. Can we influence prescribing patterns?

    Science.gov (United States)

    Sbarbaro, J A

    2001-09-15

    A variety of programming techniques and methods of training have been employed to change physician behavior. Didactic continuing medical education lectures and clinical guidelines have had minimal impact, although endorsement of national professional guidelines by local opinion leaders appears to have a positive influence on the impact of professional guidelines. Interactive, hands-on workshops, performance reporting, and peer/patient feedback are also effective. Changing prescribing habits has been equally difficult. Drug utilization letters involving both pharmacist and physician have more impact than do letters sent only to the physician. Academic detailing, when properly executed, has been consistently effective. When combined with these strategies, closed formularies become a powerful tool in changing prescribing behavior.

  12. Dose distribution, using homogeneous material before the reload of the JS-6500 irradiator

    International Nuclear Information System (INIS)

    Carrasco A, H.

    1991-10-01

    The objective of this report is to determine the dose distribution inside the aluminum containers used for the industrial irradiation, as well as to locate the positions of maximum and minimum doses, before the reloading of the JS-6500 Irradiator. (Author)

  13. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Syh, J; Patel, B; Zhang, J; Wu, H; Rosen, L [Willis-Knighton Cancer Center, Shreveport, LA (United States)

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder. The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.

  14. Prescribed burning supports grassland biodiversity - A multi-species study

    Science.gov (United States)

    Valkó, Orsolya; Deák, Balázs; Magura, Tibor; Török, Péter; Kelemen, András; Tóth, Katalin; Horváth, Roland; Nagy, Dávid; Debnár, Zsuzsanna; Zsigrai, György; Kapocsi, István; Tóthmérész, Béla

    2017-04-01

    During ancient times, fire was an important factor shaping European landscapes. Nowadays, prescribed burning can be one of the most effective conservation tools for the management of open landscapes, controlling dominant species, reducing accumulated litter or decreasing wildfire risk. In a prescribed burning experiment, we studied the effects of fire on dry alkaline grasslands. We tested whether autumn prescribed burning can be an alternative conservation measure in these grasslands. We selected six sites in Hungary: in three sites, prescribed burning was applied in November 2011, while three sites remained unburnt. We studied the effects of fire on soil characteristics, plant biomass and on the vegetation and arthropod assemblages (isopods, spiders, ground beetles and rove beetles). Soluble salt content increased significantly in the burnt sites, but soil pH, organic matter, potassium and phosphorous did not change. We found that prescribed fire had several positive effects from the nature conservation viewpoint. Diversity and the number of flowering shoots were higher, and the cover of the dominant grass was lower in the burnt sites. Graminoid biomass was lower, while total, green and forb biomass were higher in the burnt plots compared to the control ones. Our findings suggest that prescribed burning fire did not harm arthropods; species-level analyses showed that out of the most abundant invertebrate species, the abundance of ten was not affected, one decreased and one increased after burning. Our findings highlight that mosaic prescribed fire is a viable management tool in open landscapes, because it supports plant diversity and does not threaten arthropods.

  15. Antipsychotic prescribing in older people.

    Science.gov (United States)

    Neil, Wendy; Curran, Stephen; Wattis, John

    2003-09-01

    Antipsychotic medications have made a significant contribution to the care of the mentally ill people over the past 50 years, with good evidence that both typical and atypical agents are effective in the treatment of schizophrenia and related conditions. In addition they are widely used to good effect in other disorders including psychotic depression, dementia and delirium. Both typical and atypical agents may cause severe side-effects and, in the elderly in particular, there is an increased propensity for drug interactions. If used with care, antipsychotics are usually well tolerated, especially the atypical drugs. Although antipsychotics are effective at reducing psychotic symptoms their limitations should be recognised. They do not 'cure' the underlying illness, and the management of psychotic and behavioural symptoms must take into consideration treatment of physical illness as well as psychosocial interventions. In addition, the antipsychotic effect may take one to two weeks to be evident so doses should not be increased too rapidly. Often small doses are effective in the elderly if they are given sufficient time to work. As our understanding of the mechanisms of psychosis improves it is hoped that new drugs will be developed with novel mechanisms of action with improved efficacy and reduced side-effects. There are several drugs in development, some sharing similarities to currently available agents whilst others have novel mechanisms of actions involving glutamate and nicotinic receptors. Pharmacogenetics is also likely to be increasingly important over the next few years. As the genetic basis of many psychiatric disorders becomes more clearly established it is likely that drugs specifically designed for particular sub-groups of receptors will be developed. Finally, although the pharmacological treatment of psychotic disorders in younger people has been given considerable attention, there is a paucity of good quality research on antipsychotic drug use in

  16. Quality control in the process and in the irradiated food

    International Nuclear Information System (INIS)

    Farrar IV, H.

    1997-01-01

    In the irradiation process, absorbed dose is the key parameter that must be controlled. In general, the minimum absorbed dose needed to accomplish a desired effect, such as insect disinfestation or pathogen reduction, is already known from previous research, and is often prescribed by government regulations. The irradiation process is effective, however, only if the food can tolerate this dose without experiencing unwanted changes in flavor or appearance. The dose that food can tolerate often depends on such things as the variety of the fruit or vegetable, where it was grown, the season in which it was harvested and the length of time between harvesting and irradiation. Once the minimum and maximum doses are established, the irradiator operator must make sure that these dose limits are not exceeded. First, a dose mapping using many dosimeters must be undertaken to determine the locations of the minimum and maximum dose in the overall process load. From then on, the process load must always be the same, and, as a key step in the overall process control, dosimeters need to be placed from time to time only at the minimum or maximum locations. The dosimeters must be calibrated and directly trackable to national or international standards, and a fool-proof method of labelling and segregating irradiated from unirradiated product must be used. Radiation sensitive indicators that may help identify irradiated from unirradiated food should not be relied upon, and are not a substitute fro proper dosimetry. (Author)

  17. Quality control in the process and in the irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, IV, H [Chairman, ASTM Subcommittee E10.01 ` Dosimetry for Radiation Processing` , 18 Flintlock Lane, Bell Canyon, California 91307-1127 (United States)

    1998-12-31

    In the irradiation process, absorbed dose is the key parameter that must be controlled. In general, the minimum absorbed dose needed to accomplish a desired effect, such as insect disinfestation or pathogen reduction, is already known from previous research, and is often prescribed by government regulations. The irradiation process is effective, however, only if the food can tolerate this dose without experiencing unwanted changes in flavor or appearance. The dose that food can tolerate often depends on such things as the variety of the fruit or vegetable, where it was grown, the season in which it was harvested and the length of time between harvesting and irradiation. Once the minimum and maximum doses are established, the irradiator operator must make sure that these dose limits are not exceeded. First, a dose mapping using many dosimeters must be undertaken to determine the locations of the minimum and maximum dose in the overall process load. From then on, the process load must always be the same, and, as a key step in the overall process control, dosimeters need to be placed from time to time only at the minimum or maximum locations. The dosimeters must be calibrated and directly trackable to national or international standards, and a fool-proof method of labelling and segregating irradiated from unirradiated product must be used. Radiation sensitive indicators that may help identify irradiated from unirradiated food should not be relied upon, and are not a substitute fro proper dosimetry. (Author)

  18. Quality control in the process and in the irradiated food

    Energy Technology Data Exchange (ETDEWEB)

    Farrar IV, H. [Chairman, ASTM Subcommittee E10.01 `Dosimetry for Radiation Processing`, 18 Flintlock Lane, Bell Canyon, California 91307-1127 (United States)

    1997-12-31

    In the irradiation process, absorbed dose is the key parameter that must be controlled. In general, the minimum absorbed dose needed to accomplish a desired effect, such as insect disinfestation or pathogen reduction, is already known from previous research, and is often prescribed by government regulations. The irradiation process is effective, however, only if the food can tolerate this dose without experiencing unwanted changes in flavor or appearance. The dose that food can tolerate often depends on such things as the variety of the fruit or vegetable, where it was grown, the season in which it was harvested and the length of time between harvesting and irradiation. Once the minimum and maximum doses are established, the irradiator operator must make sure that these dose limits are not exceeded. First, a dose mapping using many dosimeters must be undertaken to determine the locations of the minimum and maximum dose in the overall process load. From then on, the process load must always be the same, and, as a key step in the overall process control, dosimeters need to be placed from time to time only at the minimum or maximum locations. The dosimeters must be calibrated and directly trackable to national or international standards, and a fool-proof method of labelling and segregating irradiated from unirradiated product must be used. Radiation sensitive indicators that may help identify irradiated from unirradiated food should not be relied upon, and are not a substitute fro proper dosimetry. (Author)

  19. Forum: Psychotropic prescribing in HIV | Reid | Southern African ...

    African Journals Online (AJOL)

    We provide a brief guide to the diagnosis and treatment of common mental disorders in people living with HIV/AIDS, including: prescribing psychotropics in HIV; neuropsychiatric side-effects of ARVs and other medications commonly prescribed in HIV; and the diagnosis and treatment of depression, anxiety, psychosis, ...

  20. SU-E-T-481: In Vivo and Post Mortem Animal Irradiation: Measured Vs. Calculated Doses

    Energy Technology Data Exchange (ETDEWEB)

    Heintz, P [Univ New Mexico Radiology Dept., Albuquerque, NM (United States); Heintz, B [Texas Oncology, PA, Southlake, TX (United States); Sandoval, D [University of New Mexico, Albuquerque, NM (United States); Weber, W; Melo, D; Guilmette, R [Lovelace Respiratory Research Institute, Albuquerque, NM (United States)

    2015-06-15

    Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. The subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.

  1. Systematic overview of preoperative (neoadjuvant) chemoradiotherapy trials in oesophageal cancer: Evidence of a radiation and chemotherapy dose response

    International Nuclear Information System (INIS)

    Geh, J. Ian; Bond, Simon J.; Bentzen, Soren M.; Glynne-Jones, Robert

    2006-01-01

    Background and purpose: Numerous trials have shown that pathological complete response (pCR) following preoperative chemoradiotherapy (CRT) and surgery for oesophageal cancer is associated with improved survival. However, different radiotherapy doses and fractionations and chemotherapy drugs, doses and scheduling were used, which may account for the differences in observed pCR and survival rates. A dose-response relationship may exist between radiotherapy and chemotherapy dose and pCR. Patients and methods: Trials using a single radiotherapy and chemotherapy regimen (5FU, cisplatin or mitomycin C-based) and providing information on patient numbers, age, resection and pCR rates were eligible. The endpoint used was pCR and the covariates analysed were prescribed radiotherapy dose, radiotherapy dosexdose per fraction, radiotherapy treatment time, prescribed chemotherapy (5FU, cisplatin and mitomycin C) dose and median age of patients within the trial. The model used was a multivariate logistic regression. Results: Twenty-six trials were included (1335 patients) in which 311 patients (24%) achieved pCR. The probability of pCR improved with increasing dose of radiotherapy (P=0.006), 5FU (P=0.003) and cisplatin (P=0.018). Increasing radiotherapy treatment time (P=0.035) and increasing median age (P=0.019) reduced the probability of pCR. The estimated α/β ratio of oesophageal cancer was 4.9 Gy (95% confidence interval (CI) 1.5-17 Gy) and the estimated radiotherapy dose lost per day was 0.59 Gy (95% CI 0.18-0.99 Gy). One gram per square metre of 5FU was estimated to be equivalent to 1.9 Gy (95% CI 0.8-5.2 Gy) of radiation and 100 mg/m 2 of cisplatin was estimated to be equivalent to 7.2 Gy (95% CI 2.1-28 Gy). Mitomycin C dose did not appear to influence pCR rates (P=0.60). Conclusions: There was evidence of a dose-response relationship between increasing protocol prescribed radiotherapy, 5FU and cisplatin dose and pCR. Additional significant factors were radiotherapy

  2. Prescribing for pain--how do nurses contribute? A national questionnaire survey.

    Science.gov (United States)

    Stenner, Karen; Carey, Nicola; Courtenay, Molly

    2012-12-01

    To provide information on the profile and practice of nurses in the UK who prescribe medication for pain. Pain is widely under-reported and under-treated and can have negative consequences for health and psychosocial well-being. Indications are that nurses can improve treatment and access to pain medications when they prescribe. Whilst nurses working in many practice areas treat patients with pain, little is known about the profile, prescribing practice or training needs of these nurses. A descriptive questionnaire survey. An online questionnaire was used to survey 214 nurses who prescribed for pain in the UK between May and July 2010. Data were analysed using descriptive statistics and non-parametric tests. Half the participants (50%) worked in primary care, 32% in secondary care and 14% worked across care settings. A range of services were provided, including general practice, palliative care, pain management, emergency care, walk-in-centres and out-of-hours. The majority (86%) independently prescribed 1-20 items per week. Non-opioid and weak opioids analgesics were prescribed by most (95%) nurses, whereas fewer (35%) prescribed strong opioids. Training in pain had been undertaken by 97% and 82% felt adequately trained, although 28% had problems accessing training. Those with specialist training prescribed a wider range of pain medications, were more likely to prescribe strong opioids and were more often in pain management roles. Nurses prescribe for pain in a range of settings with an emphasis on the treatment of minor ailments and acute pain. A range of medications are prescribed, and most nurses have access to training. The nursing contribution to pain treatment must be acknowledged within initiatives to improve pain management. Access to ongoing training is required to support nurse development in this area of practice to maximise benefits. © 2012 Blackwell Publishing Ltd.

  3. Improving health visitor emollient prescribing using a CQUIN-based approach.

    Science.gov (United States)

    Brooks, Christina; Khatau, Tejas

    2015-12-01

    Prescribing is an essential element of health visiting practice. This initiative used the payment framework of Commissioning for Quality and Innovation (CQUIN) to develop health visiting practice across a large health visiting workforce in the East Midlands. A focus on emollient prescribing practice was agreed and a guidance booklet regarding preferred emollient products was produced, based on the local formulary Each health visitor benefitted from receiving additional training and was given a guidance booklet to inform their practice. Targets were set for each quarter to demonstrate an improved prescribing adherence to the preferred product list.The targets were achieved for each quarter. Prescribing rates and confidence improved across the service. Therefore, it was demonstrated that specific guidance and ongoing support can improve prescribing practice within the health visiting service.

  4. Potentially inappropriate prescribing in an Irish elderly population in primary care.

    LENUS (Irish Health Repository)

    Ryan, Cristín

    2009-12-01

    WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT: * Potentially inappropriate prescribing in older people is a well-documented problem and has been associated with adverse drug reactions and hospitalization. * Beers\\' criteria, Screening Tool of Older Persons\\' potentially inappropriate Prescriptions (STOPP) and Screening Tool to Alert doctors to Right Treatment (START) are screening tools that have been formulated to help physicians and pharmacists identify potentially inappropriate prescribing and potential prescribing omissions. * The prevalence of potentially inappropriate prescribing and prescribing omissions in the elderly population presenting to hospital with acute illness is high according to STOPP and START criteria.

  5. Dental students′ compliance with antibiotic prescribing guidelines for dental infections in children

    Directory of Open Access Journals (Sweden)

    Yee Chen Wong

    2016-01-01

    Full Text Available Context: To investigate the antibiotic prescribing training received by dental students, clinical experience in treating child patients, awareness of antibiotic prescribing guidelines, preparedness in antibiotic prescribing, and compliance with antibiotic prescribing guidelines for the management of dental infections in children. Methods: This was a cross-sectional study involving final year dentals students from Malaysian and Asian dental schools. A self-administered questionnaire consisting of five clinical case scenarios was e-mailed to all final year students at selected dental schools. Students′ responses were compared for each clinical case scenario with the prescribing guidelines of the American Academy of Pediatric Dentistry and the American Dental Association. Compliance in each scenario was tested for association with their preparedness in antibiotic prescribing, previous training on antibiotic prescribing and awareness of antibiotic prescribing guidelines using Chi-square test. Data collected were analyzed using SPSS statistics version 20. Results: A total of 108 completed responses were received. About 74 (69% students were from Malaysian dental schools. The compliance rate with prescribing guidelines ranged from 15.7% to 43.5%. Those attending Malaysian dental schools (47.3% and those who had treated child patient more often (46.3% were more likely (P < 0.05 to be aware of the guidelines. Those who had received antibiotic prescribing training (21.3% were more likely to think they were well prepared in antibiotic prescribing (P < 0.05. Conclusions: Final year dental students had low awareness and compliance with antibiotic prescribing guidelines. Further research is needed to investigate how compliance with the guidelines may be enhanced.

  6. Computed tomography-based treatment planning for high-dose-rate brachytherapy using the tandem and ring applicator: influence of applicator choice on organ dose and inter-fraction adaptive planning

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2017-06-01

    Full Text Available Three dimensional planning for high-dose-rate (HDR brachytherapy in cervical cancer has been highly recommended by consensus guidelines such as the American Brachytherapy Society (ABS and the Groupe Européen de Curiethérapie – European Society for Radiotherapy and Oncology (GEC-ESTRO. In this document, we describe our experience with computed tomography (CT-based planning using the tandem/ring applicator. We discuss the influence of applicator geometry on doses to organs at risk (OARs, namely the bladder, rectum, and sigmoid. Through example cases with dose prescribed to point A, we demonstrate how adaptive planning can help achieve constraints to the OARs as per guidelines.

  7. Communicating doses of pediatric liquid medicines to parents/caregivers: a comparison of written dosing directions on prescriptions with labels applied by dispensed pharmacy.

    Science.gov (United States)

    Shah, Rita; Blustein, Leona; Kuffner, Ed; Davis, Lisa

    2014-03-01

    To identify and compare volumetric measures used by healthcare providers in communicating dosing instructions for pediatric liquid prescriptions to parents/caregivers. Dosing instructions were retrospectively reviewed for the 10 most frequently prescribed liquid medications dispensed from 4 community pharmacies for patients aged ≤ 12 years during a 3-month period. Volumetric measures on original prescriptions (ie, milliliters, teaspoons) were compared with those utilized by the pharmacist on the pharmacy label dispensed to the parent/caregiver. Of 649 prescriptions and corresponding pharmacy labels evaluated, 68% of prescriptions and 62% of pharmacy labels communicated dosing in milliliters, 24% of prescriptions and 29% of pharmacy labels communicated dosing in teaspoonfuls, 7% of prescriptions and 0% of pharmacy labels communicated dosing in other measures (ie, milligrams, cubic centimeters, "dose"), and 25% of dispensed pharmacy labels did not reflect units as written in the prescription. Volumetric measures utilized by healthcare professionals in dosing instructions for prescription pediatric oral liquid medications are not consistent. Healthcare professionals and parents/caregivers should be educated on safe dosing practices for liquid pediatric medications. Generalizability to the larger pediatric population may vary depending on pharmacy chain, location, and medications evaluated. Copyright © 2014 Mosby, Inc. All rights reserved.

  8. Nationwide radiation dose survey of computed tomography for fetal skeletal dysplasias

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu [National Center for Child Health and Development, Department of Radiology, Setagaya-ku, Tokyo (Japan); Sawai, Hideaki [Hyogo College of Medicine, Department of Obstetrics and Gynecology, Nishinomiya-shi, Hyogo (Japan); Murotsuki, Jun [Miyagi Children' s Hospital, Department of Maternal and Fetal Medicine, Sendai-shi, Miyagi (Japan); Tohoku University Graduate School of Medicine, Department of Advanced Fetal and Developmental Medicine, Sendai-shi, Miyagi (Japan); Nishimura, Gen [Tokyo Metropolitan Children' s Medical Center, Department of Pediatric Imaging, Fuchu-shi, Tokyo (Japan); Horiuchi, Tetsuya [National Center for Child Health and Development, Department of Radiology, Setagaya-ku, Tokyo (Japan); Osaka University, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Course of Health Science, Graduate School of Medicine, Suita, Osaka (Japan)

    2014-08-15

    Recently, computed tomography (CT) has been used to diagnose fetal skeletal dysplasia. However, no surveys have been conducted to determine the radiation exposure dose and the diagnostic reference level (DRL). To collect CT dose index volume (CTDIvol) and dose length product (DLP) data from domestic hospitals implementing fetal skeletal 3-D CT and to establish DRLs for Japan. Scan data of 125 cases of 20 protocols from 16 hospitals were analyzed. The minimum, first-quartile, median, third-quartile and maximum values of CTDIvol and DLP were determined. The time-dependent change in radiation dose setting in hospitals with three or more cases with scans was also examined. The minimum, first-quartile, median, third-quartile and maximum CTDIvol values were 2.1, 3.7, 7.7, 11.3 and 23.1 mGy, respectively, and these values for DLP were 69.0, 122.3, 276.8, 382.6 and 1025.6 mGy.cm, respectively. Six of the 12 institutions reduced the dose setting during the implementation period. The DRLs of CTDIvol and DLP for fetal CT were 11.3 mGy and 382.6 mGy.cm, respectively. Institutions implementing fetal CT should use these established DRLs as the standard and make an effort to reduce radiation exposure by voluntarily decreasing the dose. (orig.)

  9. Using relative humidity to predict spotfire probability on prescribed burns

    Science.gov (United States)

    John R. Weir

    2007-01-01

    Spotfires have and always will be a problem that burn bosses and fire crews will have to contend with on prescribed burns. Weather factors (temperature, wind speed and relative humidity) are the main variables burn bosses can use to predict and monitor prescribed fire behavior. At the Oklahoma State University Research Range, prescribed burns are conducted during...

  10. Analytical dose modeling for preclinical proton irradiation of millimetric targets.

    Science.gov (United States)

    Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David

    2018-01-01

    Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse

  11. Minimizing Patient-Specific Tracer Dose in Myocardial Perfusion Imaging Using CZT SPECT

    NARCIS (Netherlands)

    van Dijk, Joris David; Jager, Pieter L.; Ottervanger, Jan Paul; Slump, Cornelis H.; de Boer, Jaep; Oostdijk, Adrianus H.J.; van Dalen, Jorn A.

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT)

  12. Minimum weight design of prestressed concrete reactor pressure vessels

    International Nuclear Information System (INIS)

    Boes, R.

    1975-01-01

    A method of non-linear programming for the minimization of the volume of rotationally symmetric prestressed concrete reactor pressure vessels is presented. It is assumed that the inner shape, the loads and the degree of prestressing are prescribed, whereas the outer shape is to be detemined. Prestressing includes rotational and vertical tension. The objective function minimizes the weight of the PCRV. The constrained minimization problem is converted into an unconstrained problem by the addition of interior penalty functions to the objective function. The minimum is determined by the variable metric method (Davidson-Fletcher-Powell), using both values and derivatives of the modified objective function. The one-dimensional search is approximated by a method of Kund. Optimization variables are scaled. The method is applied to a pressure vessel like for THTR. It is found that the thickness of the cylindrical wall may be reduced considerably for the load cases considered in the optimization. The thickness of the cover is reduced slightly. The largest reduction in wall thickness occurs at the junction of wall and cover. (Auth.)

  13. Personal Doses Recorded by Service of Personal Dosimetry

    International Nuclear Information System (INIS)

    Mihai, F.; Gheorghiu, A.; Stochioiu, A.; Udup, E.

    2009-01-01

    In this work we present occupational exposure statistics on: number of workers on different dose ranges; average of the mean annual doses (MAD) over the period 2000 - 2007 on all monitored workers as well as on those who have been received doses over the minimum detection limit (MDL). The statistic is made on different types of nuclear laboratories. The data are obtained on almost 1000 workers occupational exposure to different sources of radiations (gamma and X-ray) and monitored by Photo dosimetry Survey Unit, IFIN - HH. These results point out the evolution of the individual doses received during eight years and can be used to analyse the need of radiation protection in different nuclear facilities from Romania

  14. Beyond the basics: refills by electronic prescribing.

    Science.gov (United States)

    Goldman, Roberta E; Dubé, Catherine; Lapane, Kate L

    2010-07-01

    E-prescribing is part of a new generation of electronic solutions for the medical industry that may have great potential for improving work flow and communication between medical practices and pharmacies. In the US, it has been introduced with minimal monitoring of errors and general usability. This paper examines refill functionality in e-prescribing software. A mixed method study including focus groups and surveys was conducted. Qualitative data were collected in on-site focus groups or individual interviews with clinicians and medical office staff at 64 physician office practices. Focus group participants described their experiences with the refill functionality of e-prescribing software, provided suggestions for improving it, and suggested improvements in office procedures and software functionality. Overall, approximately 50% reduction in time spent each day on refills was reported. Overall reports of refill functionality were positive; but clinicians and staff identified numerous difficulties and glitches associated managing prescription refills. These glitches diminished over time. Benefits included time saved as well as patient convenience. Potential for refilling without thought because of the ease of use was noted. Clinicians and staff appreciated the ability to track whether patients are filling and refilling prescriptions. E-prescribing software for managing medication refills has not yet reached its full potential. To reduce work flow barriers and medication errors, software companies need to develop error reporting systems and response teams to deal effectively with problems experienced by users. Examining usability issues on both the medical office and pharmacy ends is required to identify the behavioral and cultural changes that accompany technological innovation and ease the transition to full use of e-prescribing software. 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Dose escalation of chart in non-small cell lung cancer: is three-dimensional conformal radiation therapy really necessary?

    International Nuclear Information System (INIS)

    McGibney, Carol; Holmberg, Ola; McClean, Brendan; Williams, Charles; McCrea, Pamela; Sutton, Phil; Armstrong, John

    1999-01-01

    Purpose: To evaluate, pre clinically, the potential for dose escalation of continuous, hyperfractionated, accelerated radiation therapy (CHART) for non small-cell lung cancer (NSCLC), we examined the strategy of omission of elective nodal irradiation with and without the application of three-dimensional conformal radiation technology (3DCRT). Methods and Materials: 2D, conventional therapy plans were designed according to the specifications of CHART for 18 patients with NSCLC (Stages Ib, IIb, IIIa, and IIIb). Further plans were generated with the omission of elective nodal irradiation (ENI) from the treatment portals (2D minus ENI plans [2D-ENI plans]). Both sets were inserted in the patient's planning computed tomographies (CTs). These reconstructed plans were then compared to alternative, three-dimensional treatment plans which had been generated de novo, with the omission of ENI: 3D minus elective nodal irradiation (3D-ENI plans). Dose delivery to the planning target volumes (PTVs) and to the organs at risk were compared between the 3 sets of corresponding plans. The potential for dose escalation of each patient's 2D-ENI and 3D-ENI plan beyond 54 Gy, standard to CHART, was also determined. Results: PTV coverage was suboptimal in the 2D CHART and the 2D-ENI plans. Only in the 3D-ENI plans did 100% of the PTV get ≥95% of the dose prescribed (i.e., 51.5 Gy [51.3-52.2]). Using 3D-ENI plans significantly reduced the dose received by the spinal cord, the mean and median doses to the esophagus and the heart. It did not significantly reduce the lung dose when compared to 2D-ENI plans. Escalation of the dose (minimum ≥1 Gy) with optimal PTV coverage was possible in 55.5% of patients using 3D-ENI, but was possible only in 16.6% when using the 2D-ENI planning strategy. Conclusions: 3DCRT is fundamental to achieving optimal PTV coverage in NSCLC. A policy of omission of elective nodal irradiation alone (and using 2D technology) will not achieve optimal PTV coverage or

  16. Dose-Finding Study of Omeprazole on Gastric pH in Neonates with Gastro-Esophageal Acid Reflux Using a Bayesian Sequential Approach.

    Science.gov (United States)

    Kaguelidou, Florentia; Alberti, Corinne; Biran, Valerie; Bourdon, Olivier; Farnoux, Caroline; Zohar, Sarah; Jacqz-Aigrain, Evelyne

    2016-01-01

    Proton pump inhibitors are frequently administered on clinical symptoms in neonates but benefit remains controversial. Clinical trials validating omeprazole dosage in neonates are limited. The objective of this trial was to determine the minimum effective dose (MED) of omeprazole to treat pathological acid reflux in neonates using reflux index as surrogate marker. Double blind dose-finding trial with continual reassessment method of individual dose administration using a Bayesian approach, aiming to select drug dose as close as possible to the predefined target level of efficacy (with a credibility interval of 95%). Neonatal Intensive Care unit of the Robert Debré University Hospital in Paris, France. Neonates with a postmenstrual age ≥ 35 weeks and a pathologic 24-hour intra-esophageal pH monitoring defined by a reflux index ≥ 5% over 24 hours were considered for participation. Recruitment was stratified to 3 groups according to gestational age at birth. Five preselected doses of oral omeprazole from 1 to 3 mg/kg/day. Primary outcome, measured at 35 weeks postmenstrual age or more, was a reflux index reflux index ranging from 5.06 to 27.7% were included. Median age was 37.5 days and median postmenstrual age was 36 weeks. In neonates born at less than 32 weeks of GA (n = 30), the MED was 2.5mg/kg/day with an estimated mean posterior probability of success of 97.7% (95% credibility interval: 90.3-99.7%). The MED was 1mg/kg/day for neonates born at more than 32 GA (n = 24). Omeprazole is extensively prescribed on clinical symptoms but efficacy is not demonstrated while safety concerns do exist. When treatment is required, the daily dose needs to be validated in preterm and term neonates. Optimal doses of omeprazole to increase gastric pH and decrease reflux index below 5% over 24 hours, determined using an adaptive Bayesian design differ among neonates. Both gestational and postnatal ages account for these differences but their differential impact on omeprazole

  17. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  18. The Quality of Prescribing for Psychiatric Patients

    DEFF Research Database (Denmark)

    Soerensen, A L; Nielsen, L P; Poulsen, B K

    2014-01-01

    The Quality of Prescribing for Psychiatric PatientsSoerensen AL1,2, Nielsen LP3,4, Poulsen BK3, Lisby M3,5, Mainz J6,7 1Danish Center for Healthcare Improvements, Faculty of Social Sciences and Faculty of Health Sciences, Aalborg University, Denmark; 2University College of Northern Denmark; 3......, Aalborg; Denmark OBJECTIVES: Prescribing for adult psychiatric patients is often highly complex due to the nature of psychiatric conditions, but also due to somatic comorbidity. Therefore, the aim of this study was to identify prevalence and types of potential inappropriate prescribing (PIP), asses...... the severity of potential clinical consequences and identify possible predictive factors of PIP.METHODS: The study was designed as a prospective study of PIP using medication reviews. Patients who were admitted during a 4 month period (August 2013 - November 2013) to a psychiatric university hospital were...

  19. The Quality of Prescribing for Psychiatric Patients

    DEFF Research Database (Denmark)

    Sørensen, Ann Lykkegaard; Nielsen, Lars Peter; Poulsen, Birgitte Klindt

    2014-01-01

    The Quality of Prescribing for Psychiatric Patients Soerensen AL1,2, Nielsen LP3,4, Poulsen BK3, Lisby M3,5, Mainz J6,7 1Danish Center for Healthcare Improvements, Faculty of Social Sciences and Faculty of Health Sciences, Aalborg University, Denmark; 2University College of Northern Denmark; 3......, Aalborg; Denmark OBJECTIVES: Prescribing for adult psychiatric patients is often highly complex due to the nature of psychiatric conditions, but also due to somatic comorbidity. Therefore, the aim of this study was to identify prevalence and types of potential inappropriate prescribing (PIP), asses...... the severity of potential clinical consequences and identify possible predictive factors of PIP. METHODS: The study was designed as a prospective study of PIP using medication reviews. Patients who were admitted during a 4 month period (August 2013 - November 2013) to a psychiatric university hospital were...

  20. Early insights into the characteristics and evolution of clinical parameters in a cohort of patients prescribed sacubitril/valsartan in Germany.

    Science.gov (United States)

    Wachter, Rolf; Viriato, Daniel; Klebs, Sven; Grunow, Stefanie S; Schindler, Matthias; Engelhard, Johanna; Proenca, Catia C; Calado, Frederico; Schlienger, Raymond; Dworak, Markus; Balas, Bogdan; Bruce Wirta, Sara

    2018-04-01

    This study aimed to provide early insights into sacubitril/valsartan (sac/val) prescription patterns and the demographic and clinical characteristics of patients prescribed sac/val in primary care and cardiology settings in Germany. The study used electronic medical records from the German IMS® Disease Analyzer database. Patients with ≥1 prescription for sac/val during 1 January-31 December 2016 (n = 1643) were identified and followed up for ≤12 months from first prescription. Patients with ≥1 heart failure (HF) diagnosis during the study period, ≥1 additional HF diagnosis in the full history of the database, and ≥1 prescription for an angiotensin-converting enzyme inhibitor or angiotensin receptor blocker and a β-blocker during the study period, without a prescription for sac/val (n = 25,264), were included as a reference cohort. Changes in clinical parameters in the 12 months before and after sac/val initiation were investigated and compared with those from the PARADIGM-HF study. The characteristics of patients prescribed sac/val more closely resembled those of patients enrolled in PARADIGM-HF (e.g. younger age, higher proportion of men than women, lower systolic blood pressure) than patients in the reference cohort. Most patients were initiated on the lowest dose of sac/val irrespective of clinical setting. Significant decreases (p < 0.001) in NT-proBNP and glycated haemoglobin levels were observed following sac/val initiation. Patients prescribed sac/val had similar baseline demographics and clinical characteristics to those from PARADIGM-HF, and most patients were initiated on the lowest dose. Changes in clinical parameters before and after initiation mirrored findings from the PARADIGM-HF study.

  1. Lateral rectal shielding reduces late rectal morbidity after high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a dose effect

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W Robert; Hanks, Gerald E; Hanlon, Alexandra; Schultheiss, Timothy E

    1995-07-01

    Purpose: Using conventional treatment methods for the treatment of clinically localized prostate cancer central axis doses must be limited to 65-70 Gy to prevent significant damage to nearby normal tissues. A fundamental hypothesis of three-dimensional conformal radiation therapy (3DCRT) is that, by defining the target organ(s) accurately in three dimensions, it is possible to deliver higher doses to the target without a significant increase in normal tissue complications. This study examines whether this hypothesis holds true and whether a simple modification of treatment technique can reduce the incidence of late rectal morbidity in patients with prostate cancer treated with 3DCRT to minimum planning target volume (PTV) doses of 71-75 Gy. Materials and Methods: 257 patients with clinically localized prostate cancer completed 3DCRT by December 31, 1993 and received a minimum PTV dose of 71-75 Gy. The median follow-up time was 22 months (range 4-67 months) and 98% of patients had followup of longer than 12 months. The calculated dose at the center of the prostate was <74 Gy in 19 patients, 74-76 Gy in 206 patients and >76 Gy in 32 patients. Late rectal morbidity was graded according to the LENT scoring system. Eighty-eight consecutive patients were treated with a rectal block added to the lateral fields. In these patients the posterior margin from the prostate to the block edge was reduced from the standard 15 mm to 7.5 mm for the final 10 Gy which reduced the dose to portions of the anterior rectal wall by approximately 4-5 Gy. Estimates of rates for rectal morbidity were determined by Kaplan-Meier actuarial analyses. Differences in morbidity percentages were evaluated by the Pearson chi square test. Results: Grade 2-3 rectal morbidity developed in 46 of 257 patients (18%) and in the majority of cases consisted of rectal bleeding. No patient has developed grade 4 or 5 rectal morbidity. The actuarial rate of grade 2-3 morbidity is 22% at 24 months and the median

  2. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  3. Estimating fuel consumption during prescribed fires in Arkansas

    Science.gov (United States)

    Virginia L. McDaniel; James M. Guldin; Roger W. Perry

    2012-01-01

    While prescribed fire is essential to maintaining numerous plant communities, fine particles produced in smoke can impair human health and reduce visibility in scenic areas. The Arkansas Smoke Management Program was established to mitigate the impacts of smoke from prescribed fires. This program uses fuel loading and consumption estimates from standard fire-behavior...

  4. Integrated numerical platforms for environmental dose assessments of large tritium inventory facilities

    International Nuclear Information System (INIS)

    Castro, P.; Ardao, J.; Velarde, M.; Sedano, L.; Xiberta, J.

    2013-01-01

    Related with a prospected new scenario of large inventory tritium facilities [KATRIN at TLK, CANDUs, ITER, EAST, other coming] the prescribed dosimetric limits by ICRP-60 for tritium committed-doses are under discussion requiring, in parallel, to surmount the highly conservative assessments by increasing the refinement of dosimetric-assessments in many aspects. Precise Lagrangian-computations of dosimetric cloud-evolution after standardized (normal/incidental/SBO) tritium cloud emissions are today numerically open to the perfect match of real-time meteorological-data, and patterns data at diverse scales for prompt/early and chronic tritium dose assessments. The trends towards integrated-numerical-platforms for environmental-dose assessments of large tritium inventory facilities under development.

  5. What supports hospital pharmacist prescribing in Scotland? - A mixed methods, exploratory sequential study.

    Science.gov (United States)

    Fisher, J; Kinnear, M; Reid, F; Souter, C; Stewart, D

    2018-05-01

    While approximately half of all qualified hospital pharmacist independent prescribers (PIPs) in Scotland are active prescribers, there are major differences in prescribing activity across geographical areas. This study aimed to explore, through focus groups, interviews and a questionnaire, hospital PIPs' perceptions of factors associated with prescribing activity and to investigate the infrastructure required to better support active prescribing by PIPs. Findings reinforced the perceived positive impact of supportive pharmacy leadership within the organisation, recognition that prescribing is integral to the clinical pharmacist role and a work environment conducive to prescribing. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Blueprint for prescriber continuing education program.

    Science.gov (United States)

    2012-06-01

    On October 25, 2011, the Center for Drug Evaluation and Research (CDER) of the Food and Drug Administration (FDA) posted online this Blueprint for Prescriber Continuing Education, labeled "final," relating to extended-release and long-acting opioids. The pending FDA Risk Evaluation Management Strategy (REMS) requires prescriber education. This document provides guidance to sponsors of these dosage forms in developing the prescvriber education component of their REMS. This report was posted online by the federal agency on October 25, 2011 at: http://www.fda.gov/downloads/drugs/drugsafety/informationbydrugclass/ucm277916.pdf. It is in the public domain.

  7. Caracterização da dose letal mínima por irradiação gama para Penicillium citrinum Characterization of minimum lethal dosis of gama irradiation to Penicillium citrinum

    Directory of Open Access Journals (Sweden)

    A. N. Norberg

    1993-12-01

    -irradiated with doses up to 3.0 KGy. The fungus were totally destroyed with a 2.2 KGy dose. An increase in the resistance to lower dose levels of radiation was observed, in relation to the fungus which had not received irradiation. Conclusion: the Minimum Lethal Dose (MLD of gamma irradiation, for P. citrinum is 2.2 KGy; the re-irradiation of the surviving fungus demonstrate that occur appearence of radio-resistant mutants

  8. IMRT: Improvement in treatment planning efficiency using NTCP calculation independent of the dose-volume-histogram

    International Nuclear Information System (INIS)

    Grigorov, Grigor N.; Chow, James C.L.; Grigorov, Lenko; Jiang, Runqing; Barnett, Rob B.

    2006-01-01

    The normal tissue complication probability (NTCP) is a predictor of radiobiological effect for organs at risk (OAR). The calculation of the NTCP is based on the dose-volume-histogram (DVH) which is generated by the treatment planning system after calculation of the 3D dose distribution. Including the NTCP in the objective function for intensity modulated radiation therapy (IMRT) plan optimization would make the planning more effective in reducing the postradiation effects. However, doing so would lengthen the total planning time. The purpose of this work is to establish a method for NTCP determination, independent of a DVH calculation, as a quality assurance check and also as a mean of improving the treatment planning efficiency. In the study, the CTs of ten randomly selected prostate patients were used. IMRT optimization was performed with a PINNACLE3 V 6.2b planning system, using planning target volume (PTV) with margins in the range of 2 to 10 mm. The DVH control points of the PTV and OAR were adapted from the prescriptions of Radiation Therapy Oncology Group protocol P-0126 for an escalated prescribed dose of 82 Gy. This paper presents a new model for the determination of the rectal NTCP ( R NTCP). The method uses a special function, named GVN (from Gy, Volume, NTCP), which describes the R NTCP if 1 cm 3 of the volume of intersection of the PTV and rectum (R int ) is irradiated uniformly by a dose of 1 Gy. The function was 'geometrically' normalized using a prostate-prostate ratio (PPR) of the patients' prostates. A correction of the R NTCP for different prescribed doses, ranging from 70 to 82 Gy, was employed in our model. The argument of the normalized function is the R int , and parameters are the prescribed dose, prostate volume, PTV margin, and PPR. The R NTCPs of another group of patients were calculated by the new method and the resulting difference was <±5% in comparison to the NTCP calculated by the PINNACLE3 software where Kutcher's dose

  9. Minimum effective dose of intrathecal bupivacaine in combination with sulfentanil for caesarean section%布比卡因复合舒芬太尼用于剖宫产术腰麻布比卡因的最低有效剂量研究

    Institute of Scientific and Technical Information of China (English)

    肖云瑞; 钟江红; 郭检文; 杨为一; 陈柏成; 黄秀兰

    2011-01-01

    Objective To determine the minimum dose of intrathecal bupivacaine in combination with sulfentanil for caesarean section with sequential experimental method.Methods Thirty cases with a singleton full-term pregnancy for caesarean section and under combined spinal-epidural anesthesia (CSEA) were enrolled in this study.Spinal puncture was performed at the L3-4 interspace.Patients were injected intrathecally with sulfentanil 5.0 μ g and bupivacaine.The minimum local analgesic dose was determined by up-and-down sequential experiment.The initial dose of the spinal bupivacaine was decided to be 7.5 mg.If succeeded,the next case would receive bupivacaine of a lower dose if failed,the dose of bupivacaine would be increased in the next case.The dose of spinal bupivacaine increased / decreased by 0.5 mg each time.The clinical efficacy was assessed by the motor block of the lower limb,the block height,and the duration of block.If Bromage scale were Ⅲ since anesthesia was induced after 10 min and the maximum plane of sensory block was maintained at T6 since anesthesia was induced after 60 min were defined as a success.Result The minimum local analgesic dose of intrathecal bupivacaine in combination with sulfentanil 5.0 μ g for caesarean section was 5.12 mg (95% confidence interval 7.8~9.9 mg).Conclusion Determining by sequential experiment method,the minimum local analgesic dose of intrathecal bupivacaine in combination with sulfentanil 5.0 μ g for caesarean section is 5.12 mg.%目的 采用序贯法测定布比卡因复合舒芬太尼腰麻用于剖宫产术布比卡因的最低有效剂量.方法 30例单胎和妊娠足月行剖宫产术患者,于L3~4蛛网膜下腔穿刺成功后,给予舒芬太尼5.0 ug复合布比卡因腰麻,第一个病人给予布比卡因7.5 mg,每次剂量调整0.5 mg.成功:麻醉诱导10 min内改良Bromage运动阻滞评分为3级,阻滞60 min内麻醉平面维持在T6水平,下一个病人的布比卡因用量减少0.5 mg

  10. An audit of prescribing practices for benzodiazepines and Z-drugs.

    LENUS (Irish Health Repository)

    Cadogan, C

    2015-03-01

    Concerns persist over the use of benzodiazepines and Z-drugs in Ireland. A prospective prescription audit was conducted in 81 community pharmacies across Ireland over a four week period. The study sought to assess the level of prescription compliance with key components of benzodiazepine and Z-drug prescribing guidelines. 28% of audit booklets issued were returned, yielding data on 4,418 prescriptions. The findings suggest that little progress has been made in improving the prescribing of benzodiazepines and Z-drugs in Ireland in the decade since publication of the Benzodiazepine Committee\\'s report. Fewer than one fifth of prescriptions (18.8%) were fully compliant with the assessment criteria and the majority (53.7%) had multiple discrepancies. This study highlights the importance of monitoring and auditing benzodiazepine and Z-drug prescribing practices. Interventions involving patients, prescribers and pharmacists are required to improve the prescribing and use of these medications in Ireland.

  11. Rationalising prescribing: Evidence, marketing and practice-relevant knowledge.

    Science.gov (United States)

    Wadmann, Sarah; Bang, Lia E

    2015-06-01

    Initiatives in the name of 'rational pharmacotherapy' have been launched to alter what is seen as 'inappropriate' prescribing practices of physicians. Based on observations and interviews with 20 general practitioners (GPs) in 2009-2011, we explored how attempts to rationalise prescribing interact with chronic care management in Denmark. We demonstrate how attempts to rationalise prescribing by informing GPs about drug effects, adverse effects and price do not satisfy GPs' knowledge needs. We argue that, for GPs, 'rational' prescribing cannot be understood in separation from the processes that enable patients to use medication. Therefore, GPs do much more to obtain knowledge about medications than seek advice on 'rational pharmacotherapy'. For instance, GPs also seek opportunities to acquaint themselves with the material objects of medication and medical devices. We conceptualise the knowledge needs of GPs as a need for practice-relevant knowledge and argue that industry sales representatives are granted opportunity to access general practice because they understand this need of GPs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

    International Nuclear Information System (INIS)

    Yarmand, H; Winey, B; Craft, D

    2014-01-01

    Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income

  13. SU-F-BRD-08: Guaranteed Epsilon-Optimal Treatment Plans with Minimum Number of Beams for SBRT Using RayStation

    Energy Technology Data Exchange (ETDEWEB)

    Yarmand, H; Winey, B; Craft, D [Massachusetts General Hospital, Boston, MA (United States)

    2014-06-15

    Purpose: To efficiently find quality-guaranteed treatment plans with the minimum number of beams for stereotactic body radiation therapy using RayStation. Methods: For a pre-specified pool of candidate beams we use RayStation (a treatment planning software for clinical use) to identify the deliverable plan which uses all the beams with the minimum dose to organs at risk (OARs) and dose to the tumor and other structures in specified ranges. Then use the dose matrix information for the generated apertures from RayStation to solve a linear program to find the ideal plan with the same objective and constraints allowing use of all beams. Finally we solve a mixed integer programming formulation of the beam angle optimization problem (BAO) with the objective of minimizing the number of beams while remaining in a predetermined epsilon-optimality of the ideal plan with respect to the dose to OARs. Since the treatment plan optimization is a multicriteria optimization problem, the planner can exploit the multicriteria optimization capability of RayStation to navigate the ideal dose distribution Pareto surface and select a plan of desired target coverage versus OARs sparing, and then use the proposed technique to reduce the number of beams while guaranteeing quality. For the numerical experiments two liver cases and one lung case with 33 non-coplanar beams are considered. Results: The ideal plan uses an impractically large number of beams. The proposed technique reduces the number of beams to the range of practical application (5 to 9 beams) while remaining in the epsilon-optimal range of 1% to 5% optimality gap. Conclusion: The proposed method can be integrated into a general algorithm for fast navigation of the ideal dose distribution Pareto surface and finding the treatment plan with the minimum number of beams, which corresponds to the delivery time, in epsilon-optimality range of the desired ideal plan. The project was supported by the Federal Share of program income

  14. Prescribed burning: a topical issue

    Directory of Open Access Journals (Sweden)

    Bovio G

    2013-11-01

    Full Text Available Prescribed burning is a promising technique for the prevention of forest fires in Italy. The research deepened several ecological and operative aspects. However, legal issues need to be thoroughly investigated.

  15. [Prescribing antibiotics for sore throat: a persistent habit].

    Science.gov (United States)

    Damoiseaux, Roger A M J; Venekamp, Roderick P

    2015-01-01

    Recently the revision of the guideline of the Dutch College of General Practitioners on sore throat has been published. Again, one of the key messages is restricting the use of antibiotics. In the Netherlands general practitioners prescribe antibiotics in 50% of cases of tonsillitis. Although there has been a decrease in the number of antibiotic prescriptions for tonsillitis in the last 30 years, they are still being prescribed twice as often as is recommended by the guideline. The beliefs of both patient and doctor play an important role in prescribing and better communication might help to improve the situation. Public campaigns can also help by providing the best knowledge on the effectiveness of antibiotics to the public.

  16. A short-term risk-benefit analysis of occasional and regular use of low-dose aspirin in primary prevention of vascular diseases: a nationwide population-based study.

    Science.gov (United States)

    Wu, I-Chen; Hsieh, Hui-Min; Wu, Ming-Tsang

    2015-01-09

    To calculate the short-term risk-benefit effect of occasional and regular use of low-dose aspirin (≤100 mg/day) in primary prevention. Two retrospective cohort studies. Taiwan. 63 788 and 24 910 patients of two nationwide population-based studies were examined. Two databases of 1 000 000 patients were randomly sampled from data of Taiwan's National Health Insurance (NHI) for years 1997-2000 (NHI 2000) and 2005 (NHI 2005). In NHI 2000, 63 788 patients 30-95 years of age were found not to have previously been prescribed aspirin before 1 January 2000, but to have first been prescribed low-dose aspirin after that date. They were also found to be at risk of first hospitalisation for any major vascular diseases including haemorrhage (major gastrointestinal haemorrhage or cerebral haemorrhage) and ischaemia (acute myocardial infarction or ischaemic stroke) after their first prescription. We also applied it to NHI 2005, and the number of eligible patients was 24 910. Patients prescribed low-dose aspirin for risk. Vascular diseases. In NHI 2000, the overall unadjusted rates of haemorrhage and ischaemia were 0.09% and 0.21%, respectively, for occasional users and 0.32% and 2.30%, respectively, for regular users. Adjusted net clinical risk of low-dose aspirin use between the two groups was 2.24% (95% CI 2.03% to 2.48%; ppreventing major vascular diseases in primary prevention. Prescribing regular low-dose aspirin for primary prevention should be done with caution. Future studies should explore the risk-benefit effect of long-term low-dose aspirin use in primary prevention. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    Science.gov (United States)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-03-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 32 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4-6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus.

  18. Rising above the Minimum Wage.

    Science.gov (United States)

    Even, William; Macpherson, David

    An in-depth analysis was made of how quickly most people move up the wage scale from minimum wage, what factors influence their progress, and how minimum wage increases affect wage growth above the minimum. Very few workers remain at the minimum wage over the long run, according to this study of data drawn from the 1977-78 May Current Population…

  19. Impacts of prescribed fire on Pinus rigida Mill

    Science.gov (United States)

    Nicholas J. Carlo; Heidi J. Renninger; Kenneth L. Clark; Karina V.R. Schäfer

    2016-01-01

    A comparative analysis of the impacts of prescribed fire on three upland forest stands in the Northeastern Atlantic Plain, NJ, USA, was conducted. Effects of prescribed fire on water use and gas exchange of overstory pines were estimated via sap-flux rates and photosynthetic measurements on Pinus rigida Mill. Each study site had two sap-flux plots...

  20. Determination of the Minimum Effective Dosages of Praziquantel, Albendazole, and Mebendazole Against Clonorchis Sinensis Infection in Rats

    Directory of Open Access Journals (Sweden)

    Ping-Chin Fan

    2005-10-01

    Full Text Available In order to determine the minimum effective dosages of praziquantel, albendazole, and mebendazole against Clonorchis sinensis infection in Sprague-Dawley rats, each rat was infected with 30 metacercariae and treated with one of three drugs. The rats were killed and examined 25 days after praziquantel treatment or 11 days after albendazole or mebendazole treatment. The minimum effective dosages were a single dose of praziquantel 375 mg/kg, albendazole 150 mg/kg, and mebendazole 150 mg/kg. Trials are required to determine whether these dosages are useful in the treatment of human clonorchiasis.

  1. Pharmaceutical marketing research and the prescribing physician.

    Science.gov (United States)

    Greene, Jeremy A

    2007-05-15

    Surveillance of physicians' prescribing patterns and the accumulation and sale of these data for pharmaceutical marketing are currently the subjects of legislation in several states and action by state and national medical associations. Contrary to common perception, the growth of the health care information organization industry has not been limited to the past decade but has been building slowly over the past 50 years, beginning in the 1940s when growth in the prescription drug market fueled industry interest in understanding and influencing prescribing patterns. The development of this surveillance system was not simply imposed on the medical profession by the pharmaceutical industry but was developed through the interactions of pharmaceutical salesmen, pharmaceutical marketers, academic researchers, individual physicians, and physician organizations. Examination of the role of physicians and physician organizations in the development of prescriber profiling is directly relevant to the contemporary policy debate surrounding this issue.

  2. Influence of dose and dose rate on the physical properties of commercial papers commonly used in libraries and archives

    International Nuclear Information System (INIS)

    Area, María C.; Calvo, Ana M.; Felissia, Fernando E.; Docters, Andrea; Miranda, María V.

    2014-01-01

    The aim of this study was to evaluate the effects of dose and dose rate of gamma irradiation on the physical properties of commercial papers commonly used in libraries and archives to optimize the irradiation conditions. Three different brands of paper of different fiber compositions were treated, using a 3 2 factorial design with four replicates of the center point, with doses ranging from 2 to 11 kGy and dose rates between 1 and 11 kGy/h. Chemical, mechanical and optical properties were determined on the samples. With some differences between the different kinds of papers, tensile strength, elongation, TEA, and air resistance were in general, unaffected by the treatment. The minimum loss of tear resistance and brightness were obtained with doses in the range 4–6 kGy at any dose rate for all three kinds of paper. These conditions are ideal to remove insects and sufficient to eliminate fungus. - Highlights: • Gamma irradiation is a valid option to remove mold from books and documents. • We studied the effect of irradiation dose and dose rate on the physical properties of papers. • We found an optimum combination of dose and dose rate

  3. Prokinetics prescribing in paediatrics: evidence on cisapride, domperidone, and metoclopramide.

    Science.gov (United States)

    Mt-Isa, Shahrul; Tomlin, Stephen; Sutcliffe, Alastair; Underwood, Martin; Williamson, Paula; Croft, Nicholas M; Ashby, Deborah

    2015-04-01

    Domperidone and metoclopramide are prokinetics commonly prescribed off-label to infants and younger children in an attempt to treat gastro-oesophageal reflux symptoms. Another prokinetic drug, cisapride, was used but withdrawn in 2000 in the United Kingdom because of serious arrhythmic adverse events. Medicines and Healthcare Products Regulatory Agency issued safety warnings for domperidone in May 2012 and restricted its indications. We report here national primary care prescribing trends and safety signals of these drugs in children. We used data from the General Practice Research Database between 1990 and 2006 for children <18 years. Descriptive statistics and Poisson regressions were performed to characterise prescribing trends. We examined safety signals in nested case-control studies. The proportion of children <2 years old being prescribed one of the medications doubled during the study period. Prescriptions of domperidone increased 10-fold, mainly following the withdrawal of cisapride in 2000. Prescriptions of metoclopramide did not change significantly. Despite the increase in prescriptions of domperidone, no new safety signals were identified. These data showed dramatic changes in prescribing of cisapride and domperidone despite the lack of good-quality supporting evidence. It is possible that these prescribing trends were influenced by published guidelines. Even if produced without robust efficacy and safety evidence, published guidelines can influence clinicians and consequently affect prescribing. Therefore, improving the evidence base on prokinetics to inform future guidelines is vital. The lack of new safety signals during this period would support the development of suitable powered clinical studies.

  4. Prescribed computer games in addition to occlusion versus standard occlusion treatment for childhood amblyopia: a pilot randomised controlled trial.

    Science.gov (United States)

    Tailor, Vijay K; Glaze, Selina; Khandelwal, Payal; Davis, Alison; Adams, Gillian G W; Xing, Wen; Bunce, Catey; Dahlmann-Noor, Annegret

    2015-01-01

    Amblyopia ("lazy eye") is the commonest vision deficit in children. If not fully corrected by glasses, amblyopia is treated by patching or blurring the better-seeing eye. Compliance with patching is often poor. Computer-based activities are increasingly topical, both as an adjunct to standard treatment and as a platform for novel treatments. Acceptability by families has not been explored, and feasibility of a randomised controlled trial (RCT) using computer games in terms of recruitment and treatment acceptability is uncertain. We carried out a pilot RCT to test whether computer-based activities are acceptable and accessible to families and to test trial methods such as recruitment and retention rates, randomisation, trial-specific data collection tools and analysis. The trial had three arms: standard near activity advice, Eye Five, a package developed for children with amblyopia, and an off-the-shelf handheld games console with pre-installed games. We enrolled 60 children age 3-8 years with moderate or severe amblyopia after completion of optical treatment. This trial was registered as UKCRN-ID 11074. Pre-screening of 3600 medical notes identified 189 potentially eligible children, of whom 60 remained eligible after optical treatment, and were enrolled between April 2012 and March 2013. One participant was randomised twice and withdrawn from the study. Of the 58 remaining, 37 were boys. The mean (SD) age was 4.6 (1.7) years. Thirty-seven had moderate and 21 severe amblyopia. Three participants were withdrawn at week 6, and in total, four were lost to follow-up at week 12. Most children and parents/carers found the study procedures, i.e. occlusion treatment, usage of the allocated near activity and completion of a study diary, easy. The prescribed cumulative dose of near activity was 84 h at 12 weeks. Reported near activity usage numbers were close to prescribed numbers in moderate amblyopes (94 % of prescribed) but markedly less in severe amblyopes (64

  5. A thematic analysis for how patients, prescribers, experts, and patient advocates view the prescription choice process.

    Science.gov (United States)

    Schommer, Jon C; Worley, Marcia M; Kjos, Andrea L; Pakhomov, Serguei V S; Schondelmeyer, Stephen W

    2009-06-01

    Typically, patients are unaware of the cost consequences regarding prescribing decisions during their clinical encounter and rarely talk with their physicians about costs of prescription drugs. Prescription medications that are deemed by patients to be too costly when the costs become known after purchase are discontinued or used at suboptimal doses compared to prescription medications that are deemed to be worth the cost. To learn more about the prescription choice process from several viewpoints, the purpose of this study was to uncover and describe how patients, prescribers, experts, and patient advocates view the prescription choice process. Data were collected via 9 focus group interviews held between April 24 and July 31, 2007 (3 with patients, 3 with prescribers, 2 with experts, and 1 with patient advocates). The interviews were audiotaped and transcribed. The resulting text was analyzed in a descriptive and interpretive manner. Theme extraction was based on convergence and external divergence; that is, identified themes were internally consistent but distinct from one and another. To ensure quality and credibility of analysis, multiple analysts and multiple methods were used to provide a quality check on selective perception and blind interpretive bias that could occur through a single person doing all of the analysis or through employment of a single method. The findings revealed 5 overall themes related to the prescription choice process: (1) information, (2) relationship, (3) patient variation, (4) practitioner variation, and (5) role expectations. The results showed that patients, prescribers, experts, and patient advocates viewed the themes within differing contexts. It appears that the prescription choice process entails an interplay among information, relationship, patient variation, practitioner variation, and role expectations, with each viewed within different contexts by individuals engaged in such decision making.

  6. A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery

    International Nuclear Information System (INIS)

    Tyagi, Neelam; Yang Kai; Gersten, David; Yan Di

    2012-01-01

    Purpose: To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. Methods: The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the linac in clinical mode and records, displays, and compares real time machine parameters with the planned parameters. A new measure, called integral error, keeps a running total of leaf overshoot and undershoot errors in each leaf pair, multiplied by leaf width, and the amount of time during which the error exists in monitor unit delivery. Another tool reconstructs Pinnacle 3 ™ format delivered plan based on the saved machine logfile and recalculates actual delivered dose in patient anatomy. Delivery characteristics of various standard fractionation and stereotactic body radiation therapy (SBRT) VMAT plans delivered on Elekta Axesse and Synergy linacs were quantified. Results: The MLC and gantry errors for all the treatment sites were 0.00 ± 0.59 mm and 0.05 ± 0.31°, indicating a good MLC gain calibration. Standard fractionation plans had a larger gantry error than SBRT plans due to frequent dose rate changes. On average, the MLC errors were negligible but larger errors of up to 6 mm and 2.5° were seen when dose rate varied frequently. Large gantry errors occurred during the acceleration and deceleration process, and correlated well with MLC errors (r= 0.858, p= 0.0004). PTV mean, minimum, and maximum dose discrepancies were 0.87 ± 0.21%, 0.99 ± 0.59%, and 1.18 ± 0.52%, respectively. The organs at risk (OAR) doses were within 2.5%, except some OARs that showed up to 5.6% discrepancy in maximum dose. Real time displayed normalized total positive integral error (normalized to the total monitor units) correlated linearly with MLC (r= 0.9279, p < 0.001) and gantry errors (r= 0.742, p= 0.005). There is a strong correlation between total integral

  7. Primary care hypnotic and anxiolytic prescription: Reviewing prescribing practice over 8 years

    Directory of Open Access Journals (Sweden)

    Lloyd D Hughes

    2016-01-01

    Full Text Available Introduction: Over the last few years, hypnotic and anxiolytic medications have had their clinical efficacy questioned in the context of concerns regarding dependence, tolerance alongside other adverse effects. It remains unclear how these concerns have impacted clinical prescribing practice. Materials and Methods: This is a study reviewing community-dispensed prescribing data for patients on the East Practice Medical Center list in Arbroath, Scotland, in 2007, 2011 and 2015. Anxiolytic and hypnotic medications were defined in accordance with the British National Formulary chapter 4.1.1 and chapter 4.1.2. All patients receiving a drug within this class in any of the study years were collated and anonymized using primary care prescribing data. The patients′ age, gender, name of the prescribed drug(s, and total number of prescriptions in this class over the year were extracted. Results: The proportion of patients prescribed a benzodiazepine medication decreased between 2007 and 2015: 83.8% (n = 109 in 2007, 70.5% (n = 122 in 2011, and 51.7% (n = 138 in 2015 (P = 0.006. The proportion of these patients prescribed a nonbenzodiazepine drug increased between 2007 and 2015: 30% (n = 39 in 2007, 46.2% (n = 80 in 2011, and 52.4% (n = 140 in 2015 (P = 0.001. There was a significant increase in the number of patients prescribed melatonin (P = 0.020. Discussion: This study reports a reduction in benzodiazepine prescriptions in primary care alongside increases in nonbenzodiazepine and melatonin prescribing, with an increase in prescribing rates of this drug class overall. Conclusion: Changes in this prescribing practice may reflect the medicalization of insomnia, local changes in prescribing practice and alongside national recommendations.

  8. ETHICAL PRACTICES IN DRUG PRESCRIBING. A COMPARATIVE STUDY BETWEEN DOCTORS’ AND PHARMACISTS’ OPINION ABOUT DRUG PRESCRIBING IN ROMANIA

    Directory of Open Access Journals (Sweden)

    LASZLO-ZOLTAN SZTANKOVSZKY

    2015-11-01

    Full Text Available The prescription of drugs is influenced by a number of factors with a great impact upon the health of the main beneficiaries of health services. The purpose of the study is to identify the perception of doctors and pharmacists on drug prescription practices adopted by doctors. Material and Methods: a number of 349 subjects (149 pharmacists and 200 doctors answered a survey about the perception of drug dispensing in Romania. Variables like age, work environment (urban, rural, length of employment were taken into account. Results: When prescribing a treatment, 93% of doctors follow the standard treatment protocol for the given diagnosis and 93,5% of them are declaring that personal resources are the main source for training while the percent appreciated by pharmacists is evaluated to 65,78%. A total of 50% of doctors are considering other criteria than the treatment when prescribing a drug (financial contribution for the patient or National Health Insurance House. A total of 59% of doctors are recommending overthe-counter products while pharmacists consider that is happening in more than 70% of the cases. Conclusions: There are differences of opinion between doctors and pharmacists regarding doctor’s practices of prescribing drugs to their patients, like: kinds of sponsorship for the continuing education, the relationship with the pharmaceutical representative or the frequency of prescribing over-the-counter products or supplements when they are recommending a certain treatment.

  9. Teaching young GPs to cope with psychosocial consultations without prescribing: a durable impact of an e-module on determinants of benzodiazepines prescribing.

    Science.gov (United States)

    Creupelandt, Hanne; Anthierens, Sibyl; Habraken, Hilde; Declercq, Tom; Sirdifield, Coral; Siriwardena, Aloysius Niroshan; Christiaens, Thierry

    2017-12-19

    Despite guidelines and campaigns to change prescribing behavior, General Practitioners (GPs) continue to overprescribe benzodiazepines (BZDs). New approaches to improve prescribing are needed. Using behavior change techniques and tailoring interventions to user characteristics are vital to promote behavior change. This study evaluated the impact of an e-module on factors known to determine BZD prescribing practice. A tailored e-module that focuses on avoiding initial BZD prescriptions (and using psychological interventions as an alternative) was developed and offered to GPs in vocational training. Three self-report assessments took place: at baseline, immediately after the module (short term) and at least six months after completion (long term). Assessed determinants include GPs' attitudes concerning treatment options, perceptions of the patient and self-efficacy beliefs. Readiness to adhere to prescribing guidelines was evaluated through assessing motivation, self-efficacy and implementability of non-pharmacological interventions. Changes in determinants were analyzed using the Wilcoxon signed-rank test. Changes in readiness to adhere to guidelines was analyzed using the nonparametric McNemar Bowker test. A desirable, significant and durable impact on determinants of BZD prescribing was observed. GPs (n = 121) underwent desirable changes in their attitudes, perceptions and self-efficacy beliefs and these changes remained significant months after the intervention. Barriers to using a non-pharmacological approach often cited in literature remained absent and were not highlighted by the intervention. Furthermore a significant impact on GPs' readiness to adhere to guidelines was observed. Participants reported change in their ability to cope with psychosocial consultations and to have tried using non-pharmacological interventions. Tailoring an e-intervention to target group (GPs) characteristics appears to be successful in promoting behavioral change in GPs

  10. Matrix with Prescribed Eigenvectors

    Science.gov (United States)

    Ahmad, Faiz

    2011-01-01

    It is a routine matter for undergraduates to find eigenvalues and eigenvectors of a given matrix. But the converse problem of finding a matrix with prescribed eigenvalues and eigenvectors is rarely discussed in elementary texts on linear algebra. This problem is related to the "spectral" decomposition of a matrix and has important technical…

  11. SU-F-T-01: Optimization of the Accelerated Partial Breast Brachytherapy Fractionation with Consideration of Physical Doses to Tumor and Organ at Risk

    Energy Technology Data Exchange (ETDEWEB)

    Fu, W; Huq, M [University of Pittsburgh Cancer Institute Pittsburgh, PA (United States)

    2016-06-15

    Purpose: The accelerated partial breast irradiation (APBI) with brachytherapy prescribes 34Gy to be delivered in 10 fractions over 5 consecutive working days without considering the physical dose to the target and organs at risk (OARs) for an individual patient. The purpose of this study is to optimize the fractionation scheme by evaluating the radiation effect on tumor and OARs with a modified linear-quadratic (LQ) model based on dose-volume histograms (DVHs). Methods: Five breast patients treated with multilumen balloon brachytherapy were selected. The minimum skin and rib spacing were ranged from 2.5mm to 14.3mm and from 1.0mm to 25.0mm, respectively. The LQ model parameters were set as: (1) breast: α=0.08, β=0.028, doubling time Tpot=14.4 days, and starting time Tk=21days; (2) skin: acute reaction α=0.101, β=0.009; late reaction α=0.064, β=0.029; (3) rib: α=0.3, β=0.12. Boundary dose Dt was 6 Gy for both target and OARs. The relation between radiation effects on the tumor (ET) and OARs (EOAR) were plotted for fraction number from 1 to 20. Results: The value of radiation effect from routine 3.4Gyx10 fractions was used as reference, ETref and EOARref. If set ET=ETref, the fractionation that results in minimum EOAR values correspond to the optimal fractionation. For these patients, the optimal numbers are 10 fractions for skin acute reaction, 18 fractions for skin and rib late reaction while the doses per fraction are 3.4Gy and 2.05–2.10Gy, respectively. If set EOAR=EOARref, the fractionation that results in a maximum ET value corresponds to the optimal fractionation. The optimal fractionation is 3.4Gyx10 fractions for skin acute reaction, and 2.10–2.25Gyx18 fractions for skin late reaction and rib. Conclusion: For APBI brachytherapy, the routine 3.4Gyx10 fractions is optimal fractionation for skin acute reaction, while 2.05–2.25Gyx18 fractions is optimal fractionation for late reaction of skin and rib.

  12. Dichotomy in the definition of prescriptive information suggests both prescribed data and prescribed algorithms: biosemiotics applications in genomic systems.

    Science.gov (United States)

    D'Onofrio, David J; Abel, David L; Johnson, Donald E

    2012-03-14

    The fields of molecular biology and computer science have cooperated over recent years to create a synergy between the cybernetic and biosemiotic relationship found in cellular genomics to that of information and language found in computational systems. Biological information frequently manifests its "meaning" through instruction or actual production of formal bio-function. Such information is called prescriptive information (PI). PI programs organize and execute a prescribed set of choices. Closer examination of this term in cellular systems has led to a dichotomy in its definition suggesting both prescribed data and prescribed algorithms are constituents of PI. This paper looks at this dichotomy as expressed in both the genetic code and in the central dogma of protein synthesis. An example of a genetic algorithm is modeled after the ribosome, and an examination of the protein synthesis process is used to differentiate PI data from PI algorithms.

  13. Dichotomy in the definition of prescriptive information suggests both prescribed data and prescribed algorithms: biosemiotics applications in genomic systems

    Directory of Open Access Journals (Sweden)

    D'Onofrio David J

    2012-03-01

    Full Text Available Abstract The fields of molecular biology and computer science have cooperated over recent years to create a synergy between the cybernetic and biosemiotic relationship found in cellular genomics to that of information and language found in computational systems. Biological information frequently manifests its "meaning" through instruction or actual production of formal bio-function. Such information is called Prescriptive Information (PI. PI programs organize and execute a prescribed set of choices. Closer examination of this term in cellular systems has led to a dichotomy in its definition suggesting both prescribed data and prescribed algorithms are constituents of PI. This paper looks at this dichotomy as expressed in both the genetic code and in the central dogma of protein synthesis. An example of a genetic algorithm is modeled after the ribosome, and an examination of the protein synthesis process is used to differentiate PI data from PI algorithms.

  14. Investigation of Prescribed Fires Impacts on Air Quality in the Pacific Northwest

    Science.gov (United States)

    Ravi, V.; Chung, S. H.; Vaughan, J. K.; Lamb, B. K.

    2014-12-01

    Emissions from wildland and prescribed fires cause significant aerosol loading in the atmospheric environment. Using 2011 NEI-Fire emission inventory, we investigate the impacts of prescribed fire emissions on the air quality of the Pacific Northwest (PNW) for a month long period in October-November 2011. This study utilizes the AIRAPCT-4 regional air quality forecasting system, which is based on the WRF-SMOKE-CMAQ framework. We simulate three different emission scenarios - 1) emissions with prescribed fires, 2) emissions without prescribed fires and 3) a scenario where prescribed fire emissions are reduced by 60%. AIRPACT-4 results are examined for impacts of prescribed fire emissions on ambient levels of PM2.5 and Ozone for entire PNW. We also look at the contribution of prescribed fire emissions to ambient PM2.5 concentrations for selected non-attainment areas in the PNW. This work supports the analysis of using woody residue as a feedstock for an aviation biofuel supply chain through the Northwest Advanced Renewables Alliance (NARA).

  15. Prevalence of inappropriate prescribing in primary care

    DEFF Research Database (Denmark)

    Bregnhøj, Lisbeth; Thirstrup, Steffen; Kristensen, Mogens Brandt

    2007-01-01

    to the patients. Topical, dermatological medications and medications not used regularly were excluded. RESULTS: 212 patients were prescribed 1621 medications by their GPs at baseline. In all, 640 (39.5%) of the medications had one or more inappropriate ratings in the 10 criteria making up the MAI. The main part...... is good. However, the majority of patients used one or more medications with inappropriate ratings. The inappropriate prescribing relates to specific therapeutic groups and criteria, which should be targeted in future interventions....

  16. The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Pla, Conrado; Al-Amro, Abdullah S.; Bahary, Jean-Paul; Villemure, Jean-Guy; Caron, Jean-Louis; Olivier, Andre; Podgorsak, Ervin B.

    1998-01-01

    Purpose: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. Materials and Methods: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. Results: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. Conclusions: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue

  17. An overiew of non medical prescribing across one strategic health authority: a questionnaire survey

    Directory of Open Access Journals (Sweden)

    Courtenay Molly

    2012-06-01

    Full Text Available Abstract Background Over 50,000 non-medical healthcare professionals across the United Kingdom now have prescribing capabilities. However, there is no evidence available with regards to the extent to which non-medical prescribing (NMP has been implemented within organisations across a strategic health authority (SHA. The aim of the study was to provide an overview of NMP across one SHA. Methods NMP leads across one SHA were asked to supply the email addresses of NMPs within their organisation. One thousand five hundred and eighty five NMPs were contacted and invited to complete an on-line descriptive questionnaire survey, 883 (55.7% participants responded. Data was collected between November 2010 and February 2011. Results The majority of NMPs were based in primary care and worked in a team of 2 or more. Nurse independent supplementary prescribers were the largest group (590 or 68.6% compared to community practitioner prescribers (198 or 22.4%, pharmacist independent supplementary prescribers (35 or 4%, and allied health professionals and optometrist independent and/or supplementary prescribers (8 or 0.9%. Nearly all (over 90% of nurse independent supplementary prescribers prescribed medicines. Approximately a third of pharmacist independent supplementary prescribers, allied health professionals, and community practitioner prescribers did not prescribe. Clinical governance procedures were largely in place, although fewer procedures were reported by community practitioner prescribers. General practice nurses prescribed the most items. Factors affecting prescribing practice were: employer, the level of experience prior to becoming a non-medical prescriber, existence of governance procedures and support for the prescribing role (p  Conclusion NMP in this strategic health authority reflects national development of this relatively new role in that the majority of non-medical prescribers were nurses based in primary care, with fewer pharmacist and

  18. An overiew of non medical prescribing across one strategic health authority: a questionnaire survey.

    Science.gov (United States)

    Courtenay, Molly; Carey, Nicola; Stenner, Karen

    2012-06-01

    Over 50,000 non-medical healthcare professionals across the United Kingdom now have prescribing capabilities. However, there is no evidence available with regards to the extent to which non-medical prescribing (NMP) has been implemented within organisations across a strategic health authority (SHA). The aim of the study was to provide an overview of NMP across one SHA. NMP leads across one SHA were asked to supply the email addresses of NMPs within their organisation. One thousand five hundred and eighty five NMPs were contacted and invited to complete an on-line descriptive questionnaire survey, 883 (55.7%) participants responded. Data was collected between November 2010 and February 2011. The majority of NMPs were based in primary care and worked in a team of 2 or more. Nurse independent supplementary prescribers were the largest group (590 or 68.6%) compared to community practitioner prescribers (198 or 22.4%), pharmacist independent supplementary prescribers (35 or 4%), and allied health professionals and optometrist independent and/or supplementary prescribers (8 or 0.9%). Nearly all (over 90%) of nurse independent supplementary prescribers prescribed medicines. Approximately a third of pharmacist independent supplementary prescribers, allied health professionals, and community practitioner prescribers did not prescribe. Clinical governance procedures were largely in place, although fewer procedures were reported by community practitioner prescribers. General practice nurses prescribed the most items. Factors affecting prescribing practice were: employer, the level of experience prior to becoming a non-medical prescriber, existence of governance procedures and support for the prescribing role (p < 0.001). NMP in this strategic health authority reflects national development of this relatively new role in that the majority of non-medical prescribers were nurses based in primary care, with fewer pharmacist and allied health professional prescribers. This

  19. Monte Carlo skin dose simulation in intraoperative radiotherapy of breast cancer using spherical applicators

    Science.gov (United States)

    Moradi, F.; Ung, N. M.; Khandaker, M. U.; Mahdiraji, G. A.; Saad, M.; Malik, R. Abdul; Bustam, A. Z.; Zaili, Z.; Bradley, D. A.

    2017-08-01

    The relatively new treatment modality electronic intraoperative radiotherapy (IORT) is gaining popularity, irradiation being obtained within a surgically produced cavity being delivered via a low-energy x-ray source and spherical applicators, primarily for early stage breast cancer. Due to the spatially dramatic dose-rate fall off with radial distance from the source and effects related to changes in the beam quality of the low keV photon spectra, dosimetric account of the Intrabeam system is rather complex. Skin dose monitoring in IORT is important due to the high dose prescription per treatment fraction. In this study, modeling of the x-ray source and related applicators were performed using the Monte Carlo N-Particle transport code. The dosimetric characteristics of the model were validated against measured data obtained using an ionization chamber and EBT3 film as dosimeters. By using a simulated breast phantom, absorbed doses to the skin for different combinations of applicator size (1.5-5 cm) and treatment depth (0.5-3 cm) were calculated. Simulation results showed overdosing of the skin (>30% of prescribed dose) at a treatment depth of 0.5 cm using applicator sizes larger than 1.5 cm. Skin doses were significantly increased with applicator size, insofar as delivering 12 Gy (60% of the prescribed dose) to skin for the largest sized applicator (5 cm diameter) and treatment depth of 0.5 cm. It is concluded that the recommended 0.5-1 cm distance between the skin and applicator surface does not guarantee skin safety and skin dose is generally more significant in cases with the larger applicators. Highlights: • Intrabeam x-ray source and spherical applicators were simulated and skin dose was calculated. • Skin dose for constant skin to applicator distance strongly depends on applicator size. • Use of larger applicators generally results in higher skin dose. • The recommended 0.5-1 cm skin to applicator distance does not guarantee skin

  20. The possibility of the dose limitation system application non-ionizing radiation protection

    International Nuclear Information System (INIS)

    Ranisavljevic, M., Markovic, S.

    1997-01-01

    Modern conception of the ionizing radiation protection is based on Dose Limitation System. In the base of every human decision lies compromise. Balance between positive and negative factors, benefit and detriment, profit and expense includes the decision about possibilities for realization any defined radiation practice. The optimal option for the given value of the varying parameter gives the maximum benefit and the minimum detriment. In radiation protection field, detriment is related with human health or expenses, and varying parameter is level of radiation protection (for example dimensions of the installed shielding). The problem lies in fact that for the given value of the varying shielding parameter the maximum benefit and the minimum detriment are not achievable simultaneously because the greater benefit includes the greater expense. The problems which have to be solved because of introducing Dose Limitation System, in regard to create Modified Dose Limitation System, are presented. (author)

  1. Employment effects of minimum wages

    OpenAIRE

    Neumark, David

    2014-01-01

    The potential benefits of higher minimum wages come from the higher wages for affected workers, some of whom are in low-income families. The potential downside is that a higher minimum wage may discourage employers from using the low-wage, low-skill workers that minimum wages are intended to help. Research findings are not unanimous, but evidence from many countries suggests that minimum wages reduce the jobs available to low-skill workers.

  2. Hardness, function, emotional well-being, satisfaction and the overall sexual experience in men using 100-mg fixed-dose or flexible-dose sildenafil citrate.

    Science.gov (United States)

    Ströberg, P; Kaminetsky, J C; Park, N C; Goldfischer, E R; Creanga, D L; Stecher, V J

    2010-01-01

    The prescribing information for sildenafil citrate (VIAGRA, Pfizer, New York, NY, USA) recommends flexible dosing (50 mg initially, adjusted to 100 or 25 mg based on effectiveness and tolerability) in most men with erectile dysfunction (ED). In many men, however, 100 mg may be the most appropriate initial dose because it would reduce the need for titration and could prevent discouragement and treatment abandonment should 50 mg be insufficient. Results of two previously published double-blind, placebo-controlled sildenafil trials of similar design except for a fixed-dose vs flexible-dose regimen were analyzed. Relative to the flexible-dose, approximately one-third more men were satisfied with an initial and fixed dose of 100 mg. In addition, tolerability was similar, and improvements from baseline in outcomes on validated, ED-specific, patient-reported questionnaires were either similar (erectile function and the percentage of completely hard and fully rigid erections) or greater (emotional well-being and the overall sexual experience). The similarity in outcomes is not surprising given that almost 90% of the men in the flexible-dose trial titrated to 100 mg after 2 weeks. These data suggest prescription of an initial dose of 100 mg for men with ED, except in those for whom it is inappropriate.

  3. Prescribed and self-reported seasonal training of distance runners.

    Science.gov (United States)

    Hewson, D J; Hopkins, W G

    1995-12-01

    A survey of 123 distance-running coaches and their best runners was undertaken to describe prescribed seasonal training and its relationship to the performance and self-reported training of the runners. The runners were 43 females and 80 males, aged 24 +/- 8 years (mean +/- S.D.), training for events from 800 m to the marathon, with seasonal best paces of 86 +/- 6% of sex- and age-group world records. The coaches and runners completed a questionnaire on typical weekly volumes of interval and strength training, and typical weekly volumes and paces of moderate and hard continuous running, for build-up, pre-competition, competition and post-competition phases of a season. Prescribed training decreased in volume and increased in intensity from the build-up through to the competition phase, and had similarities with 'long slow distance' training. Coaches of the faster runners prescribed longer build-ups, greater volumes of moderate continuous running and slower relative paces of continuous running (r = 0.19-0.36, P training close to competition pace. The mean training volumes and paces prescribed by the coaches were similar to those reported by the runners, but the correlations between prescribed and reported training were poor (r = 0.2-0.6). Coaches may therefore need to monitor their runners' training more closely.

  4. Dose mapping of the multi-purpose gamma irradiation facility

    Energy Technology Data Exchange (ETDEWEB)

    Cabalfin, E G; Lanuza, L G; Villamater, D T [Irradiation Services, Nuclear Services and Training Division, Philippine Nuclear Research Institute, Quezon City (Philippines)

    1989-12-01

    In radiation processing, reliable dosimetry constitutes a very important part of process control and quality assurance. Radiation dosimetry is the only acceptable method to guarantee that the irradiated product has undergone the correct radiation treatment. In preparation therefore, for the routine operation of the newly installed multi-purpose gamma irradiation facility at the Philippine Nuclear Research Institute (PNRI), dose mapping distribution studies were undertaken. Results of dose distribution in air as well as in dummy product are presented. The effects of product bulk density, product geometry and product to source distance on minimum absorbed dose and uniformity ratio have been determined. (Author).

  5. Dose mapping of the multi-purpose gamma irradiation facility

    International Nuclear Information System (INIS)

    Cabalfin, E.G.; Lanuza, L.G.; Villamater, D.T.

    1989-01-01

    In radiation processing, reliable dosimetry constitutes a very important part of process control and quality assurance. Radiation dosimetry is the only acceptable method to guarantee that the irradiated product has undergone the correct radiation treatment. In preparation therefore, for the routine operation of the newly installed multi-purpose gamma irradiation facility at the Philippine Nuclear Research Institute (PNRI), dose mapping distribution studies were undertaken. Results of dose distribution in air as well as in dummy product are presented. The effects of product bulk density, product geometry and product to source distance on minimum absorbed dose and uniformity ratio have been determined. (Author)

  6. Drug prescribing pattern in three levels of health care facilities in the ...

    African Journals Online (AJOL)

    tabulation and goodness of fit. Results showed that there is significant statistical differences in the number of drugs prescribed per patient encounter, percentage of encounter with an injection prescribed, in adherence to WHO prescribing ...

  7. High-Dose Chloroquine for Treatment of Chloroquine-Resistant Plasmodium falciparum Malaria

    DEFF Research Database (Denmark)

    Ursing, Johan; Rombo, Lars; Bergqvist, Yngve

    2016-01-01

    BACKGROUND:  Due to development of multidrug-resistant Plasmodium falciparum new antimalarial therapies are needed. In Guinea-Bissau, routinely used triple standard-dose chloroquine remained effective for decades despite the existence of "chloroquine-resistant" P. falciparum. This study aimed...... to determine the in vivo efficacy of higher chloroquine concentrations against P. falciparum with resistance-conferring genotypes. METHODS:  Standard or double-dose chloroquine was given to 892 children aged ...-up. The P. falciparum resistance-conferring genotype (pfcrt 76T) and day 7 chloroquine concentrations were determined. Data were divided into age groups (chloroquine is prescribed according to body weight. RESULTS:  Adequate clinical...

  8. Impact of Internally Developed Electronic Prescription on Prescribing Errors at Discharge from the Emergency Department.

    Science.gov (United States)

    Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif

    2017-08-01

    Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%-38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive.

  9. Factors influencing pharmacists' adoption of prescribing: qualitative application of the diffusion of innovations theory.

    Science.gov (United States)

    Makowsky, Mark J; Guirguis, Lisa M; Hughes, Christine A; Sadowski, Cheryl A; Yuksel, Nese

    2013-09-14

    In 2007, Alberta became the first Canadian jurisdiction to grant pharmacists a wide range of prescribing privileges. Our objective was to understand what factors influence pharmacists' adoption of prescribing using a model for the Diffusion of Innovations in healthcare services. Pharmacists participated in semi-structured telephone interviews to discuss their prescribing practices and explore the facilitators and barriers to implementation. Pharmacists working in community, hospital, PCN, or other settings were selected using a mix of random and purposive sampling. Two investigators independently analyzed each transcript using an Interpretive Description approach to identify themes. Analyses were informed by a model explaining the Diffusion of Innovations in health service organizations. Thirty-eight participants were interviewed. Prescribing behaviours varied from non-adoption through to product, disease, and patient focused use of prescribing. Pharmacists' adoption of prescribing was dependent on the innovation itself, adopter, system readiness, and communication and influence. Adopting pharmacists viewed prescribing as a legitimization of previous practice and advantageous to instrumental daily tasks. The complexity of knowledge required for prescribing increased respectively in product, disease and patient focused prescribing scenarios. Individual adopters had higher levels of self-efficacy toward prescribing skills. At a system level, pharmacists who were in practice settings that were patient focused were more likely to adopt advanced prescribing practices, over those in product-focused settings. All pharmacists stated that physician relationships impacted their prescribing behaviours and individual pharmacists' decisions to apply for independent prescribing privileges. Diffusion of Innovations theory was helpful in understanding the multifaceted nature of pharmacists' adoption of prescribing. The characteristics of the prescribing model itself which

  10. Variations in Metformin Prescribing for Type 2 Diabetes.

    Science.gov (United States)

    Goldberg, Tiffany; Kroehl, Miranda E; Suddarth, Kathleen Heist; Trinkley, Katy E

    2015-01-01

    Reasons for suboptimal metformin prescribing are unclear, but may be due to perceived risk of lactic acidosis. The purpose of this study is to describe provider attitudes regarding metformin prescribing in various patient situations. An anonymous, electronic survey was distributed electronically to 76 health care providers across the nation. The 14-item survey contained demographic questions and questions related to prescribing of metformin for T2DM in various patient situations, including suboptimal glycemic control, alcohol use, history of lactic acidosis, and varying degrees of severity for certain health conditions, including renal and hepatic dysfunction, chronic obstructive pulmonary disease, and heart failure. There were a total of 100 respondents. For suboptimal glycemic control, most providers (75%) would increase metformin from 1500 to 2000 mg daily; however, 25% would add an alternate agent, such as a sulfonylurea (18%) or dipeptidyl peptidase-4 inhibitor (7%). Although 51% of providers would stop metformin based on serum creatinine thresholds, the remainder would rely on glomerular filtration rate thresholds of <60 mL/min (15%), <30 mL/min (33%), or <15 mL/min (1%) to determine when to stop metformin. For heart failure, 45% of providers would continue metformin as currently prescribed regardless of severity. Most providers would adjust metformin for varying severity of hepatic dysfunction (74%) and alcohol abuse (40%). Despite evidence supporting the cardiovascular benefits of metformin, provider attitudes toward prescribing metformin are suboptimal in certain patient situations and vary greatly by provider. © Copyright 2015 by the American Board of Family Medicine.

  11. Opioid Prescribing PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2017-07-06

    This 60 second public service announcement is based on the July 2017 CDC Vital Signs report. Higher opioid prescribing puts patients at risk for addiction and overdose. Learn what can be done about this serious problem.  Created: 7/6/2017 by Centers for Disease Control and Prevention (CDC).   Date Released: 7/6/2017.

  12. Operational use of prescribed fire in southern California chaparral

    Science.gov (United States)

    Ron Dougherty; Philip J. Riggan

    1982-01-01

    The use of prescribed fire in the chaparral could reduce the incidence and impacts of severe wildfires and enhance watershed re-sources. This paper describes the operational planning needed for a successful prescribed fire and discusses the recent experience with this technique on the Cleveland National Forest.

  13. Community-Based Prescribing for Impetigo in Remote Australia: An Opportunity for Antimicrobial Stewardship.

    Science.gov (United States)

    Oliver, Stefanie Jane; Cush, James; Ward, Jeanette E

    2017-01-01

    To support antibiotic prescribing for both hospital and community-based health professionals working in remote North Western Australia, a multidisciplinary Antimicrobial Stewardship (AMS) Committee was established in 2013. This Committee is usually focused on hospital-based prescribing. A troubling increase in sulfamethoxazole/trimethoprim resistance in Staphylococcus aureus antibiograms from 9 to 18% over 1 year prompted a shift in gaze to community prescribing. Finding a paucity of relevant research, we first investigated contextual factors influencing local prescribing. We also designed a systematic survey of experts with experience relevant to our setting using a structured response survey (12 questions) to better understand specific AMS risks. Using these findings, recommendations were formulated for the AMS Committee. Prescribing recommendations in a regional Skin Infections Protocol had previously been altered in December 2014. From 15 experts, we received 9 comprehensive responses (60%) about AMS risks in community prescribing. If feasible, prescribing audits also would have been valuable. Ten recommendations regarding specific antibiotic recommendations were submitted to the AMS Committee. As AMS Committees in Australia usually focus on hospital-based prescribing, novel methods such as external expert opinion could inform deliberations about community-based prescribing. Our approach meant that this AMS Committee was able to intervene in the 2017 organizational review of the regional Skin Infections Protocol used by prescribers likely unaware of AMS risks. This experience demonstrates the value of incorporating AMS principles in community-based prescribing in context of a remote setting.

  14. Computed radiography dose optimization in pediatric patients

    International Nuclear Information System (INIS)

    Juste, B.; Verdu, G.; Tortosa, R.; Villaescusa, J.I.

    2008-01-01

    Radiation dose reduction in pediatric X-ray imaging is especially important because of children radiation sensitivity. For any radiographic examination performed at a fixed radiographic tube potential, the patient absorbed dose is directly proportional to the value of milliampere-seconds (mAs) selected by the operator. Nevertheless, reducing X-ray exposure has the unavoidable disadvantage of increasing the quantum noise in the resultant image. The objective of this work is to identify the minimum tube current setting required for maintaining accurate examinations, to modify, if required, the daily protocols applied at La Fe de Valencia Universitary Hospital. To accomplish this goal, a noise addition software has been developed in order to study the diagnostic accuracy as a function of reducing dose by artificially increasing the image noise. The noise addition tool has been applied to several thorax images acquired from pediatric unit to simulate new lower dose radiographies and allow medical researchers to study how lower dose affects the patient pneumonia diagnosis. (author)

  15. Prescribing smoked cannabis for chronic noncancer pain

    Science.gov (United States)

    Kahan, Meldon; Srivastava, Anita; Spithoff, Sheryl; Bromley, Lisa

    2014-01-01

    Objective To offer preliminary guidance on prescribing smoked cannabis for chronic pain before the release of formal guidelines. Quality of evidence We reviewed the literature on the analgesic effectiveness of smoked cannabis and the harms of medical and recreational cannabis use. We developed recommendations on indications, contraindications, precautions, and dosing of smoked cannabis, and categorized the recommendations based on levels of evidence. Evidence is mostly level II (well conducted observational studies) and III (expert opinion). Main message Smoked cannabis might be indicated for patients with severe neuropathic pain conditions who have not responded to adequate trials of pharmaceutical cannabinoids and standard analgesics (level II evidence). Smoked cannabis is contraindicated in patients who are 25 years of age or younger (level II evidence); who have a current, past, or strong family history of psychosis (level II evidence); who have a current or past cannabis use disorder (level III evidence); who have a current substance use disorder (level III evidence); who have cardiovascular or respiratory disease (level III evidence); or who are pregnant or planning to become pregnant (level II evidence). It should be used with caution in patients who smoke tobacco (level II evidence), who are at increased risk of cardiovascular disease (level III evidence), who have anxiety or mood disorders (level II evidence), or who are taking higher doses of opioids or benzodiazepines (level III evidence). Cannabis users should be advised not to drive for at least 3 to 4 hours after smoking, for at least 6 hours after oral ingestion, and for at least 8 hours if they experience a subjective “high” (level II evidence). The maximum recommended dose is 1 inhalation 4 times per day (approximately 400 mg per day) of dried cannabis containing 9% delta-9-tetrahydrocannabinol (level III evidence). Physicians should avoid referring patients to “cannabinoid” clinics (level

  16. Nonparametric estimation of benchmark doses in environmental risk assessment

    Science.gov (United States)

    Piegorsch, Walter W.; Xiong, Hui; Bhattacharya, Rabi N.; Lin, Lizhen

    2013-01-01

    Summary An important statistical objective in environmental risk analysis is estimation of minimum exposure levels, called benchmark doses (BMDs), that induce a pre-specified benchmark response in a dose-response experiment. In such settings, representations of the risk are traditionally based on a parametric dose-response model. It is a well-known concern, however, that if the chosen parametric form is misspecified, inaccurate and possibly unsafe low-dose inferences can result. We apply a nonparametric approach for calculating benchmark doses, based on an isotonic regression method for dose-response estimation with quantal-response data (Bhattacharya and Kong, 2007). We determine the large-sample properties of the estimator, develop bootstrap-based confidence limits on the BMDs, and explore the confidence limits’ small-sample properties via a short simulation study. An example from cancer risk assessment illustrates the calculations. PMID:23914133

  17. Antibiotic prescribing practices for catheter urine culture results.

    Science.gov (United States)

    Chiu, Jonathan; Thompson, G William; Austin, Thomas W; Hussain, Zafar; John, Michael; Bombassaro, Anne Marie; Connelly, Sarah E; Elsayed, Sameer

    2013-01-01

    The literature suggests that positive results of catheter urine cultures frequently lead to unnecessary antimicrobial prescribing, which therefore represents an important target for stewardship. To assess the appropriateness of antibiotic prescribing in response to the results of urine cultures from patients with indwelling urinary catheters. This retrospective study was conducted at a tertiary care centre and involved adults with indwelling urinary catheters from whom urine specimens were obtained for culture. Patients with positive or negative culture results were identified from microbiology laboratory reports. The medical records of consecutive patients were screened to select a sample of 80 inpatients (40 per group). Abstracted patient histories were independently evaluated by an expert panel of 3 infectious diseases consultants blinded to the decisions of prescribers and of fellow panelists. The primary end point was concordance of each patient's treatment decision (with respect to the indication) between the expert panel (based on majority agreement, i.e., at least 2 of the 3 expert panelists) and the prescriber. The secondary end points were unnecessary days of therapy and selected outcomes over a predefined period after urine was obtained for culture. A total of 591 charts were screened to generate the targeted number of patients. Baseline demographic characteristics were comparable for the 2 groups, except antibiotic exposure before urine collection was significantly more frequent for the group with negative culture results. The treatment decision was concordant in 40% (16/40) of the patients with a positive culture result and 85% (34/40) of those with a negative culture result (p < 0.001). The most common reason for discordance was administration of antibiotics when not indicated (23 of 24 patients with a positive result and 5 of 6 patients with a negative result), which accounted for 165 and 32 unnecessary days of therapy per 1000 inpatient

  18. Prescribing medical cannabis in Canada: Are we being too cautious?

    Science.gov (United States)

    Lake, Stephanie; Kerr, Thomas; Montaner, Julio

    2015-04-30

    There has been much recent discussion and debate surrounding cannabis in Canada, including the prescribing of medical cannabis for therapeutic purposes. Certain commentators - including the Canadian Medical Association (CMA) - have denounced the prescribing of cannabis for medical purposes due to a perceived lack of evidence related to the drug's efficacy, harms, and mechanism of action. In this commentary, we present arguments in favour of prescribing medical cannabis in Canada. We believe the anti-cannabis position taken by CMA and other commentators is not entirely evidence-based. Using the example of neuropathic pain, we present and summarize the clinical evidence surrounding smoked or vapourized cannabis, including recent evidence pertaining to the effectiveness of cannabis in comparison to existing standard pharmacotherapies for neuropathy. Further, we outline how the concerns expressed regarding cannabis' mechanism of action are inconsistent with current decision-making processes related to the prescribing of many common pharmaceuticals. Finally, we discuss potential secondary public health benefits of prescribing cannabis for pain-related disorders in Canada and North America.

  19. Association between respiratory prescribing, air pollution and deprivation, in primary health care.

    Science.gov (United States)

    Sofianopoulou, Eleni; Rushton, Stephen P; Diggle, Peter J; Pless-Mulloli, Tanja

    2013-12-01

    We investigated the association between respiratory prescribing, air quality and deprivation in primary health care. Most previous studies have used data from secondary and tertiary care to quantify air pollution effects on exacerbations of asthma and chronic obstructive pulmonary disease (COPD). However, these outcomes capture patients who suffer from relatively severe symptoms. This is a population-based ecological study. We analysed respiratory medication (salbutamol) prescribed monthly by 63 primary care practices, UK. Firstly, we captured the area-wide seasonal variation in prescribing. Then, using the area-wide variation in prescribing as an offset, we built a mixed-effects model to assess the remaining variation in relation to air quality and demographic variables. An increase of 10 μg/m(3) in ambient PM10 was associated with an increase of 1% (95% CI: 0.1-2%) in salbutamol prescribing. An increase of 1 SD in income and employment deprivation was associated with an increase of 20.5% (95% CI: 8.8-33.4%) and 14.7% (95% CI: 4.3-26.2%) in salbutamol prescribing rate, respectively. The study provides evidence that monthly respiratory prescribing in primary care is a useful indicator of the extent to which air pollution exacerbates asthma and COPD symptoms. Respiratory prescribing was higher on deprived populations.

  20. Pattern of Self Prescribed Analgesic Use in a Rural Area of Delhi: Exploring the Potential Role of Internet.

    Science.gov (United States)

    Kochhar, Anjali; Gupta, Tanya

    2017-07-01

    Analgesics are the most common self prescribed drugs. Although considered to be relatively safe, side effects are often seen when these drugs are used for prolonged period, in high doses or used where contraindicated. Majority of the consumers are not aware of the side effects. These days ample amount of information is available on web, it is important to explore its role in educating the population regarding the safe use of self prescribed analgesics. To explore pattern of analgesic use, to identify population at risk of developing side effects related to analgesic use, awareness of side effects and potential role of internet to bring awareness about safe use of self prescribed analgesic drugs in a rural area of Delhi. A cross-sectional survey based study was done on 500 adults in the age group of 18-65 years of Madanpur Khadar area of South Delhi, India. Data collection was done by conducting visits to pharmacy shops from the people who were buying drugs without prescription and taking face to face interviews using a semi-structured questionnaire. Statistical analysis was performed using descriptive tests with Microsoft office excel 2007. Results of our study showed that among all the self prescribed analgesics paracetamol (57%) was used most frequently followed by aspirin and other NSAIDs. It was found that 9.6% of the consumers were having associated co-morbid illness, 11.4% were simultaneously taking other drugs and 15.2% were alcoholics. Majority (65.4%) of the buyers were not aware about any kind of side effects of the analgesics. Internet friendly consumers were found to be 44%. Ability to use internet and education level were found to be directly related (r=0.802). The pattern of analgesic consumption in the rural population of Delhi shows that a large number of consumers may be at risk of developing side effects of self prescribed analgesics. The awareness about the side effects is limited. A significant number of consumers are internet friendly. Hence

  1. Statin prescribing according to gender, age and indication

    DEFF Research Database (Denmark)

    Wallach-Kildemoes, Helle; Støvring, Henrik; Holme Hansen, Ebba

    2016-01-01

    RATIONALES, AIMS AND OBJECTIVES: The increasing dispensing of statins has raised concern about the appropriateness of prescribing to various population groups. We aimed to (1) investigate incident and prevalent statin prescribing according to indication, gender and age and (2) relate prescribing...... patterns to evidence on beneficial and adverse effects. METHODS: A cohort of Danish inhabitants (n = 4 424 818) was followed in nationwide registries for dispensed statin prescriptions and hospital discharge information. We calculated incidence rates (2005-2009), prevalence trends (2000-2010) and absolute...... numbers of statin users according to register proxies for indication, gender and age. RESULTS: In 2010, the prevalence became highest for ages 75-84 and was higher in men than women (37% and 33%, respectively). Indication-specific incidences and prevalences peaked at ages around 65-70, but in myocardial...

  2. Nonopioid substance use disorders and opioid dose predict therapeutic opioid addiction.

    Science.gov (United States)

    Huffman, Kelly L; Shella, Elizabeth R; Sweis, Giries; Griffith, Sandra D; Scheman, Judith; Covington, Edward C

    2015-02-01

    Limited research examines the risk of therapeutic opioid addiction (TOA) in patients with chronic noncancer pain. This study examined TOA among 199 patients undergoing long-term opioid therapy at the time of admission to a pain rehabilitation program. It was hypothesized that nonopioid substance use disorders and opioid dosage would predict TOA. Daily mean opioid dose was 132.85 mg ± 175.39. Patients with nonopioid substance use disorders had 28 times the odds (odds ratio [OR] = 28.58; 95% confidence interval [CI] = 10.86, 75.27) of having TOA. Each 50-mg increase in opioid dose nearly doubled the odds of TOA (OR = 1.73; 95% CI = 1.29, 2.32). A 100-mg increase was associated with a 3-fold increase in odds (OR = 3.00; 95% CI = 1.67, 5.41). Receiver operating characteristic analysis revealed that opioid dose was a moderately accurate predictor (area under the curve = .75; 95% CI = .68, .82) of TOA. The sensitivity (.70) and specificity (.68) of opioid dose in predicting TOA was maximized at 76.10 mg; in addition, 46.00 mg yielded 80% sensitivity in identifying TOA. These results underscore the importance of obtaining a substance use history prior to prescribing and suggest a low screening threshold for TOA in patients who use opioids in the absence of improvement in pain or functional impairment. This article examines TOA in patients with chronic noncancer pain undergoing long-term opioid therapy. Results suggest that patients should be screened for nonopioid substance use disorders prior to prescribing. In the absence of improvement in pain or function, there is a low threshold (∼50 mg daily opioid dose) for addiction screening. Copyright © 2015 American Pain Society. Published by Elsevier Inc. All rights reserved.

  3. Minimum Wages and Poverty

    OpenAIRE

    Fields, Gary S.; Kanbur, Ravi

    2005-01-01

    Textbook analysis tells us that in a competitive labor market, the introduction of a minimum wage above the competitive equilibrium wage will cause unemployment. This paper makes two contributions to the basic theory of the minimum wage. First, we analyze the effects of a higher minimum wage in terms of poverty rather than in terms of unemployment. Second, we extend the standard textbook model to allow for incomesharing between the employed and the unemployed. We find that there are situation...

  4. Evaluating Alternative Prescribed Burning Policies to Reduce Net Economic Damages from Wildfire

    OpenAIRE

    D. Evan Mercer; Jeffrey P. Prestemon; David T. Butry; John M. Pye

    2007-01-01

    We estimate a wildfire risk model with a new measure of wildfire output, intensity-weighted risk and use it in Monte Carlo simulations to estimate welfare changes from alternative prescribed burning policies. Using Volusia County, Florida as a case study, an annual prescribed burning rate of 13% of all forest lands maximizes net welfare; ignoring the effects on wildfire intensity may underestimate optimal rates of prescribed burning. Our estimated supply function for prescribed fire services ...

  5. Effects of prescribed fires on soil properties: A review.

    Science.gov (United States)

    Alcañiz, M; Outeiro, L; Francos, M; Úbeda, X

    2018-02-01

    Soils constitute one of the most valuable resources on earth, especially because soil is renewable on human time scales. During the 20th century, a period marked by a widespread rural exodus and land abandonment, fire suppression policies were adopted facilitating the accumulation of fuel in forested areas, exacerbating the effects of wildfires, leading to severe degradation of soils. Prescribed fires emerged as an option for protecting forests and their soils from wildfires through the reduction of fuels levels. However such fires can serve other objectives, including stimulating the regeneration of a particular plant species, maintaining biological diversity or as a tool for recovering grasslands in encroached lands. This paper reviews studies examining the short- and long- term impacts of prescribed fires on the physical, chemical and biological soil properties; in so doing, it provides a summary of the benefits and drawbacks of this technique, to help determine if prescribed fires can be useful for managing the landscape. From the study conducted, we can affirm that prescribed fires affects soil properties but differ greatly depending on soil initial characteristics, vegetation or type of fire. Also, it is possible to see that soil's physical and biological properties are more strongly affected by prescribed fires than are its chemical properties. Finally, we conclude that prescribed fires clearly constitute a disturbance on the environment (positive, neutral or negative depending on the soil property studied), but most of the studies reviewed report a good recovery and their effects could be less pronounced than those of wildfires because of the limited soil heating and lower fire intensity and severity. Copyright © 2017. Published by Elsevier B.V.

  6. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Directory of Open Access Journals (Sweden)

    Munmun Koley

    2014-10-01

    Full Text Available A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H, Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items and patient care indicators (5 items. Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791. The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65 to 0.74 (95% CI: 0.69-0.78. The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48 to 0.82 (95% CI: 0.78-0.85. The instrument also showed high discriminant validity (prescribing indicators P<0.0001 and patient care indicators P<0.0001. Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development.

  7. A Validation Study of Homeopathic Prescribing and Patient Care Indicators

    Science.gov (United States)

    Koley, Munmun; Saha, Subhranil; Ghosh, Shubhamoy; Nag, Goutam; Kundu, Monojit; Mondal, Ramkumar; Purkait, Rajib; Patra, Supratim

    2014-01-01

    A preliminary version of the homeopathic prescribing and patient care indicators was available. The instrument was modified further in this study with an intention to address formally its validity and reliability, audit prescriptions, identify areas of sub-optimal prescribing, and highlight target areas for improving the quality of practices. A cross-sectional study with record analysis was conducted on systematically sampled 377 patients of Mahesh Bhattacharyya Homeopathic Medical College and Hospital (MBHMC and H), Howrah, West Bengal, India. The outcome measures were homeopathic prescribing indicators (6 items) and patient care indicators (5 items). Individualized homeopathic prescriptions predominated in the encounters. Areas demanding immediate attention were extremely poor labeling of drugs dispensed from the hospital pharmacy, improper record of case history and disease diagnosis, ongoing therapies, and investigational findings in the prescriptions. Internal consistency of the overall instrument was estimated to be good (Cronbach's alpha: Prescribing indicators 0.752 and patient care indicators 0.791). The prescribing indicators, except items 1 and 3, reflected acceptable item-corrected total correlations – Pearson's r from 0.58 (95% CI: 0.52-0.65) to 0.74 (95% CI: 0.69-0.78). The patient care indicators, except item 2, showed acceptable correlations – Pearson's r from 0.40 (95% CI: 0.31-0.48) to 0.82 (95% CI: 0.78-0.85). The instrument also showed high discriminant validity (prescribing indicators P < 0.0001 and patient care indicators P < 0.0001). Improper prescribing practice was quite rampant and corrective measures are warranted. The developed indicators appeared to be validated and reliable; however, they are amendable for further development. PMID:25379474

  8. Qualitative analysis of multi-disciplinary round-table discussions on the acceleration of benefits and data analytics through hospital electronic prescribing (ePrescribing) systems.

    Science.gov (United States)

    Cresswell, Kathrin; Coleman, Jamie; Smith, Pam; Swainson, Charles; Slee, Ann; Sheikh, Aziz

    2016-07-04

    Electronic systems that facilitate prescribing, administration and dispensing of medicines (ePrescribing systems) are at the heart of international efforts to improve the safety, quality and efficiency of medicine management. Considering the initial costs of procuring and maintaining ePrescribing systems, there is a need to better understand how to accelerate and maximise the financial benefits associated with these systems. We sought to investigate how different sectors are approaching the realisation of returns on investment from ePrescribing systems in U.K. hospitals and what lessons can be learned for future developments and implementation strategies within healthcare settings. We conducted international, multi-disciplinary, round-table discussions with 21 participants from different backgrounds including policy makers, healthcare organisations, academic researchers, vendors and patient representatives. The discussions were audio-recorded, transcribed and then thematically analysed with the qualitative analysis software NVivo10. There was an over-riding concern that realising financial returns from ePrescribing systems was challenging. The underlying reasons included substantial fixed costs of care provision, the difficulties in radically changing the medicines management process and the lack of capacity within NHS hospitals to analyse and exploit the digital data being generated. Any future data strategy should take into account the need to collect and analyse local and national data (i.e. within and across hospitals), setting comparators to measure progress (i.e. baseline measurements) and clear standards guiding data management so that data are comparable across settings. A more coherent national approach to realising financial benefits from ePrescribing systems is needed as implementations progress and the range of tools to collect information will lead to exponential data growth. The move towards more sophisticated closed-loop systems that integrate

  9. Qualitative analysis of multi-disciplinary round-table discussions on the acceleration of benefits and data analytics through hospital electronic prescribing (ePrescribing systems

    Directory of Open Access Journals (Sweden)

    Kathrin Cresswell

    2016-07-01

    Full Text Available Background: Electronic systems that facilitate prescribing, administration and dispensing of medicines (ePrescribing systems are at the heart of international efforts to improve the safety, quality and efficiency of medicine management. Considering the initial costs of procuring and maintaining ePrescribing systems, there is a need to better understand how to accelerate and maximise the financial benefits associated with these systems. Objectives: We sought to investigate how different sectors are approaching the realisation of returns on investment from ePrescribing systems in U.K. hospitals and what lessons can be learned for future developments and implementation strategies within healthcare settings. Methods: We conducted international, multi-disciplinary, round-table discussions with 21 participants from different backgrounds including policy makers, healthcare organisations, academic researchers, vendors and patient representatives. The discussions were audio-recorded, transcribed and then thematically analysed with the qualitative analysis software NVivo10. Results: There was an over-riding concern that realising financial returns from ePrescribing systems was challenging. The underlying reasons included substantial fixed costs of care provision, the difficulties in radically changing the medicines management process and the lack of capacity within NHS hospitals to analyse and exploit the digital data being generated. Any future data strategy should take into account the need to collect and analyse local and national data (i.e. within and across hospitals, setting comparators to measure progress (i.e. baseline measurements and clear standards guiding data management so that data are comparable across settings. Conclusions: A more coherent national approach to realising financial benefits from ePrescribing systems is needed as implementations progress and the range of tools to collect information will lead to exponential data growth. The

  10. Community-Based Prescribing for Impetigo in Remote Australia: An Opportunity for Antimicrobial Stewardship

    Directory of Open Access Journals (Sweden)

    Stefanie Jane Oliver

    2017-07-01

    Full Text Available BackgroundTo support antibiotic prescribing for both hospital and community-based health professionals working in remote North Western Australia, a multidisciplinary Antimicrobial Stewardship (AMS Committee was established in 2013. This Committee is usually focused on hospital-based prescribing. A troubling increase in sulfamethoxazole/trimethoprim resistance in Staphylococcus aureus antibiograms from 9 to 18% over 1 year prompted a shift in gaze to community prescribing.What we didFinding a paucity of relevant research, we first investigated contextual factors influencing local prescribing. We also designed a systematic survey of experts with experience relevant to our setting using a structured response survey (12 questions to better understand specific AMS risks. Using these findings, recommendations were formulated for the AMS Committee.What we learnedPrescribing recommendations in a regional Skin Infections Protocol had previously been altered in December 2014. From 15 experts, we received 9 comprehensive responses (60% about AMS risks in community prescribing. If feasible, prescribing audits also would have been valuable. Ten recommendations regarding specific antibiotic recommendations were submitted to the AMS Committee.Strengthening AMS in remote settingsAs AMS Committees in Australia usually focus on hospital-based prescribing, novel methods such as external expert opinion could inform deliberations about community-based prescribing. Our approach meant that this AMS Committee was able to intervene in the 2017 organizational review of the regional Skin Infections Protocol used by prescribers likely unaware of AMS risks. This experience demonstrates the value of incorporating AMS principles in community-based prescribing in context of a remote setting.

  11. 75 FR 6151 - Minimum Capital

    Science.gov (United States)

    2010-02-08

    ... capital and reserve requirements to be issued by order or regulation with respect to a product or activity... minimum capital requirements. Section 1362(a) establishes a minimum capital level for the Enterprises... entities required under this section.\\6\\ \\3\\ The Bank Act's current minimum capital requirements apply to...

  12. A Pareto-Improving Minimum Wage

    OpenAIRE

    Eliav Danziger; Leif Danziger

    2014-01-01

    This paper shows that a graduated minimum wage, in contrast to a constant minimum wage, can provide a strict Pareto improvement over what can be achieved with an optimal income tax. The reason is that a graduated minimum wage requires high-productivity workers to work more to earn the same income as low-productivity workers, which makes it more difficult for the former to mimic the latter. In effect, a graduated minimum wage allows the low-productivity workers to benefit from second-degree pr...

  13. Safer Prescribing and Care for the Elderly (SPACE): feasibility of audit and feedback plus practice mail-out to patients with high-risk prescribing.

    Science.gov (United States)

    Wallis, Katharine; Tuckey, Rebecca

    2017-06-01

    INTRODUCTION High-risk prescribing in general practice is common and places patients at increased risk of adverse events. AIM The Safer Prescribing and Care for the Elderly (SPACE) intervention, comprising audit and feedback plus practice mail-out to patients with high-risk prescribing, was designed to promote medicines review and support safer prescribing. This study aims to test the SPACE intervention feasibility in general practice. METHODS This feasibility study involved an Auckland Primary Health Organisation (PHO), a clinical advisory pharmacist, two purposively sampled urban general practices, and seven GPs. The acceptability and utility of the SPACE intervention were assessed by semi- structured interviews involving study participants, including 11 patients with high-risk prescribing. Interviews were audio-recorded, transcribed verbatim and analysed using a general inductive approach to identify emergent themes. RESULTS The pharmacist said the SPACE intervention facilitated communication with GPs, and provided a platform for their clinical advisory role at no extra cost to the PHO. GPs said the feedback session with the pharmacist was educational but added to time pressures. GPs selected 29 patients for the mail-out. Some GPs were concerned the mail-out might upset patients, but patients said they felt cared for. Some patients intended to take the letter to their next appointment and discuss their medicines with their GP; others said there were already many things to discuss and not enough time. Some patients were confused by the medicines information brochure. DISCUSSION The SPACE intervention is feasible in general practice. The medicines information brochure needs simplification. Further research is needed to test the effect of SPACE on high-risk prescribing.

  14. Nurse prescribing for inpatient pain in the United Kingdom: a national questionnaire survey.

    Science.gov (United States)

    Stenner, Karen L; Courtenay, Molly; Cannons, Karin

    2011-07-01

    Nurses make a valuable contribution to pain services and have the potential to improve the safety and effectiveness of pain management. A recent addition to the role of the specialist pain nurse in the United Kingdom has been the introduction of prescribing rights, however there is a lack of literature about their role in prescribing pain medication. The aim of this study was to develop a profile of the experience, role and prescribing practice of these nurses. A descriptive questionnaire survey. 192 National Health Service public hospital inpatient pain services across the United Kingdom. 161 qualified nurse prescribers were invited to participate, representing 98% of known nurse prescribers contributing to inpatient pain services. The survey was completed in November 2009 by 137 nurses; a response rate of 85%. Compared with nurse prescribers in the United Kingdom in general, participants were highly qualified and experienced pain specialists. Fifty-six percent had qualified as a prescriber in the past 3 years and 22% reported that plans were underway for more nurses to undertake a nurse prescribing qualification. Although all participants worked in inpatient pain services, 35% also covered chronic pain (outpatient) services and 90% treated more than one pain type. A range of pain medications were prescribed, averaging 19.5 items per week. The role contained a strong educational component and contributed to informing organisational policy on pain management. Prescribing was said to improve nurses' ability to promote evidence-based practice but benefits were limited by legislation on prescribing controlled drugs. Findings demonstrate that pain nurses are increasingly adopting prescribing as part of their advanced nurse role. This has implications for the development needs of pain nurses in the United Kingdom and the future role development of nurses in other countries. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Stakeholders' views on granting prescribing authority to pharmacists in Nigeria: a qualitative study.

    Science.gov (United States)

    Auta, Asa; Strickland-Hodge, Barry; Maz, Julia

    2016-08-01

    Background In Nigeria, only medical doctors, dentists and some nurses in primary care facilities have the legal right to prescribe medicines to patients. Patients' access to prescription medicines can be seriously affected by the shortage of prescribers leading to longer waiting times in hospitals. Objective This research was carried out to investigate stakeholders' views on granting prescribing authority to pharmacists in Nigeria. Setting The study was conducted in Nigeria. Methods Qualitative, semi-structured interviews were conducted with 43 Nigerian stakeholders including policymakers, pharmacists, doctors and patient group representatives. Transcribed interviews were entered into the QSR NVivo 10 software and analysed using a thematic approach. Main outcome measure Stakeholders' perception on the granting of prescribing authority to pharmacists in Nigeria. Results Three major themes emerged from the interviews: (1) prescribing as a logical role for pharmacists, (2) pharmacist prescribing- an opportunity or a threat and (3) the potential barriers to pharmacist prescribing. Many non-medical stakeholders including pharmacists and patient group representatives supported an extended role for pharmacists in prescribing while the majority of medical doctors including those in policy making were reluctant to do so. Generally, all stakeholders perceived that pharmacist prescribing represents an opportunity to increase patients' access to medicines, reduce doctors' workload and promote the utilisation of pharmacists' skills. However, many stakeholders including pharmacists and doctors commonly identified pharmacists' inadequate skills in diagnosis, medical resistance and shortage of pharmacists as potential barriers to the introduction of pharmacist prescribing in Nigeria. Conclusion The present study showed a split of opinion between participants who were medical doctors and those who were non-doctors in their support for pharmacist prescribing. However, all

  16. Experience of micromultileaf collimator linear accelerator based single fraction stereotactic radiosurgery: Tumor dose inhomogeneity, conformity, and dose fall off

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Linda X.; Garg, Madhur; Lasala, Patrick; Kim, Mimi; Mah, Dennis; Chen, Chin-Cheng; Yaparpalvi, Ravindra; Mynampati, Dinesh; Kuo, Hsiang-Chi; Guha, Chandan; Kalnicki, Shalom [Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Neurosurgery, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Epidemiology and Population Health, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States); Department of Radiation Oncology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York 10461 (United States)

    2011-03-15

    Purpose: Sharp dose fall off outside a tumor is essential for high dose single fraction stereotactic radiosurgery (SRS) plans. This study explores the relationship among tumor dose inhomogeneity, conformity, and dose fall off in normal tissues for micromultileaf collimator (mMLC) linear accelerator (LINAC) based cranial SRS plans. Methods: Between January 2007 and July 2009, 65 patients with single cranial lesions were treated with LINAC-based SRS. Among them, tumors had maximum diameters {<=}20 mm: 31; between 20 and 30 mm: 21; and >30 mm: 13. All patients were treated with 6 MV photons on a Trilogy linear accelerator (Varian Medical Systems, Palo Alto, CA) with a tertiary m3 high-resolution mMLC (Brainlab, Feldkirchen, Germany), using either noncoplanar conformal fixed fields or dynamic conformal arcs. The authors also created retrospective study plans with identical beam arrangement as the treated plan but with different tumor dose inhomogeneity by varying the beam margins around the planning target volume (PTV). All retrospective study plans were normalized so that the minimum PTV dose was the prescription dose (PD). Isocenter dose, mean PTV dose, RTOG conformity index (CI), RTOG homogeneity index (HI), dose gradient index R{sub 50}-R{sub 100} (defined as the difference between equivalent sphere radius of 50% isodose volume and prescription isodose volume), and normal tissue volume (as a ratio to PTV volume) receiving 50% prescription dose (NTV{sub 50}) were calculated. Results: HI was inversely related to the beam margins around the PTV. CI had a ''V'' shaped relationship with HI, reaching a minimum when HI was approximately 1.3. Isocenter dose and mean PTV dose (as percentage of PD) increased linearly with HI. R{sub 50}-R{sub 100} and NTV{sub 50} initially declined with HI and then reached a plateau when HI was approximately 1.3. These trends also held when tumors were grouped according to their maximum diameters. The smallest tumor group

  17. Biological effective dose studies in carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.

    2008-01-01

    Cancer of cervix is the second most common cancer worldwide among women. Several treatments related protocols of radiotherapy have been followed over few decades in its treatment for evaluating the response. These physical doses varying on the basics of fractionation size, dose rate and total dose needed to be indicated as biological effective dose (BED) to rationalize these treatments. The curative potential of radiation therapy in the management of carcinoma of the cervix is greatly enhanced by the use of intracavitary brachytherapy. Successful brachytherapy requires the high radiation dose to be delivered to the tumor where as minimum radiation dose reach to surrounding normal tissue. Present study is aimed to evaluate biologically effective dose in patients receiving high dose-rate brachytherapy plus external beam radiotherapy based on tumor cell proliferation values in cancer of the cervix patients. The study includes 30 patients' data as a retrospective analysis. In addition determine extent of a dose-response relationship existing between the biological effective dose at Point A and the bladder and rectum and the clinical outcomes

  18. Gonad doses in biliary tract examinations (cholecystography)

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, I [Staedtisches Klinikum Berlin-Buch (German Democratic Republic). Roentgendiagnostisches Zentrum; Angerstein, W [Forschungsinstitut fuer Tuberkulose und Lungenkrankheiten, Berlin (German Democratic Republic); Koenig, W; Menzel, B [Staatliches Amt fuer Atomsicherheit und Strahlenschutz, Berlin (German Democratic Republic)

    1979-02-01

    622 single measurements of gonad doses were performed during cholecystography in patients of either sex (intravaginally in women). In oral cholecystography on an average 13 mR were revealed for men and 149 mR for women, resp. According to a minimum, medium, or maximum extent of examination, in intravenous cholecystography the data for men were 11, 17, and 24 mR, while the corresponding data for women were 93, 185, and 278 mR. Based on about 400,000 cholegraphic examinations per year in the GDR the contribution to the total gonad dose caused by radiological examinations is 6-8%.

  19. Gonad doses in biliary tract examinations (cholecystography)

    International Nuclear Information System (INIS)

    Radtke, I.; Koenig, W.; Menzel, B.

    1979-01-01

    622 single measurements of gonad doses were performed during cholecystography in patients of either sex (intravaginally in women). In oral cholecystography on an average 13 mR were revealed for men and 149 mR for women, resp. According to a minimum, medium, or maximum extent of examination, in intravenous cholecystography the data for men were 11, 17, and 24 mR, while the corresponding data for women were 93, 185, and 278 mR. Based on about 400,000 cholegraphic examinations per year in the GDR the contribution to the total gonad dose caused by radiological examinations is 6-8%. (author)

  20. Shrub resprouting response after fuel reduction treatments: comparison of prescribed burning, clearing and mastication.

    Science.gov (United States)

    Fernández, Cristina; Vega, José A; Fonturbel, Teresa

    2013-03-15

    Fuel reduction treatments are commonly used to reduce the risk of severe wildfire. However, more information about the effects on plant resprouting is needed to help land managers select the most appropriate treatment. To address this question, we evaluated the resprouting ability of five shrub species after the application of different types of fuel reduction methods (prescribed burning, clearing and mastication) in two contrasting shrubland areas in northern Spain. The shrub species were Erica australis, Pterospartum tridentatum and Halimium lasianthum spp. alyssoides, Ulex gallii and Erica cinerea. For most of the species under study (E. australis, P. tridentatum, H. lasianthum spp. alyssoides and U. gallii), neither plant mortality nor the number nor length of sprouted shoots per plant differed between treatments, although in E. cinerea the number of shoots was more negatively affected by prescribed burning than by clearing or mastication. The pre-treatment plant size did not affect plant mortality or plant resprouting response, suggesting that this parameter alone is not a good indicator of plant resprouting after fuel reduction treatments. Stem minimum diameter after treatments, a proxy of treatment severity, was not related to plant mortality, number or length of resprouted shoots. The duration of temperatures higher than 300 °C during burning in plant crown had a negative effect on the length of resprouted shoots, only in E. cinerea. The results show that fuel reduction treatments did not prevent shrub response in any case. Some reflections on the applicability of treatments are discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Optimal initial dose adjustment of warfarin in orthopedic patients.

    Science.gov (United States)

    Lenzini, Petra A; Grice, Gloria R; Milligan, Paul E; Gatchel, Susan K; Deych, Elena; Eby, Charles S; Burnett, R Stephen J; Clohisy, John C; Barrack, Robert L; Gage, Brian F

    2007-11-01

    Warfarin sodium is commonly prescribed for the prophylaxis and treatment of venous thromboembolism. Dosing algorithms have not been widely adopted because they require a fixed initial warfarin dose (eg, 5 mg) and are not tailored to other factors that may affect the international normalized ratio (INR). To develop an algorithm that could predict a therapeutic warfarin dose based on drug interactions, INR response after the initial warfarin doses, and other clinical factors. We used stepwise regression to quantify the relationship between these factors in patients beginning prophylactic warfarin therapy immediately prior to joint replacement. In the derivation cohort (n = 271), we separately modeled the therapeutic dose after 2 and 3 initial doses. We prospectively validated these 2 models in an independent cohort (n = 105). About half of the therapeutic dose variability was predictable after 3 days of therapy: R2 was 53% in the derivation cohort and 42% in the validation cohort. INR response after 3 warfarin doses (INR3) inversely correlated with therapeutic dose (p < 0.001). Intraoperative blood loss transiently, but significantly, elevated the postoperative INR values. Other significant (p < 0.03) predictors were the first and second warfarin doses (+7% and +6%, respectively, per 1 mg), and statin use (-15.0%). The model derived after 2 warfarin doses explained 32% of the variability in therapeutic dose. We developed and validated algorithms that estimate therapeutic warfarin doses based on clinical factors and INR response available after 2-3 days of warfarin therapy. The algorithms are implemented online at www.WarfarinDosing.org.

  2. Using scenarios to test the appropriateness of pharmacist prescribing in asthma management

    Directory of Open Access Journals (Sweden)

    Hanna T

    2014-03-01

    Full Text Available Objective: To explore the potential for community pharmacist prescribing in terms of usefulness, pharmacists’ confidence, and appropriateness, in the context of asthma management. Methods: Twenty community pharmacists were recruited using convenience sampling from a group of trained practitioners who had already delivered asthma services. These pharmacists were asked to complete a scenario-based questionnaire (9 scenarios modelled on information from real patients. Pharmacist interventions were independently reviewed and rated on their appropriateness according to the Respiratory Therapeutic Guidelines (TG by three expert researchers. Results: In seven of nine scenarios (78%, the most common prescribing intervention made by pharmacists agreed with TG recommendations. Although the prescribing intervention was appropriate in the majority of cases, the execution of such interventions was not in line with guidelines (i.e. dosage or frequency in the majority of scenarios. Due to this, only 47% (76/162 of the interventions overall were considered appropriate. However, pharmacists were deemed to be often following common clinical practice for asthma prescribing. Therefore 81% (132/162 of prescribing interventions were consistent with clinical practice, which is often not guideline driven, indicating a need for specific training in prescribing according to guidelines. Pharmacists reported that they were confident in making prescribing interventions and that this would be very useful in their management of the patients in the scenarios. Conclusion: Community pharmacists may be able to prescribe asthma medications appropriately to help achieve good outcomes for their patients. However, further training in the guidelines for prescribing are required if pharmacists are to support asthma management in this way.

  3. Using scenarios to test the appropriateness of pharmacist prescribing in asthma management.

    Science.gov (United States)

    Hanna, Tamer; Bajorek, Beata; Lemay, Kate; Armour, Carol L

    2014-01-01

    To explore the potential for community pharmacist prescribing in terms of usefulness, pharmacists' confidence, and appropriateness, in the context of asthma management. Twenty community pharmacists were recruited using convenience sampling from a group of trained practitioners who had already delivered asthma services. These pharmacists were asked to complete a scenario-based questionnaire (9 scenarios) modelled on information from real patients. Pharmacist interventions were independently reviewed and rated on their appropriateness according to the Respiratory Therapeutic Guidelines (TG) by three expert researchers. In seven of nine scenarios (78%), the most common prescribing intervention made by pharmacists agreed with TG recommendations. Although the prescribing intervention was appropriate in the majority of cases, the execution of such interventions was not in line with guidelines (i.e. dosage or frequency) in the majority of scenarios. Due to this, only 47% (76/162) of the interventions overall were considered appropriate. However, pharmacists were deemed to be often following common clinical practice for asthma prescribing. Therefore 81% (132/162) of prescribing interventions were consistent with clinical practice, which is often not guideline driven, indicating a need for specific training in prescribing according to guidelines. Pharmacists reported that they were confident in making prescribing interventions and that this would be very useful in their management of the patients in the scenarios. Community pharmacists may be able to prescribe asthma medications appropriately to help achieve good outcomes for their patients. However, further training in the guidelines for prescribing are required if pharmacists are to support asthma management in this way.

  4. Using scenarios to test the appropriateness of pharmacist prescribing in asthma management

    Science.gov (United States)

    Hanna, Tamer; Bajorek, Beata; LeMay, Kate; Armour, Carol L.

    Objective To explore the potential for community pharmacist prescribing in terms of usefulness, pharmacists’ confidence, and appropriateness, in the context of asthma management. Methods Twenty community pharmacists were recruited using convenience sampling from a group of trained practitioners who had already delivered asthma services. These pharmacists were asked to complete a scenario-based questionnaire (9 scenarios) modelled on information from real patients. Pharmacist interventions were independently reviewed and rated on their appropriateness according to the Respiratory Therapeutic Guidelines (TG) by three expert researchers. Results In seven of nine scenarios (78%), the most common prescribing intervention made by pharmacists agreed with TG recommendations. Although the prescribing intervention was appropriate in the majority of cases, the execution of such interventions was not in line with guidelines (i.e. dosage or frequency) in the majority of scenarios. Due to this, only 47% (76/162) of the interventions overall were considered appropriate. However, pharmacists were deemed to be often following common clinical practice for asthma prescribing. Therefore 81% (132/162) of prescribing interventions were consistent with clinical practice, which is often not guideline driven, indicating a need for specific training in prescribing according to guidelines. Pharmacists reported that they were confident in making prescribing interventions and that this would be very useful in their management of the patients in the scenarios. Conclusions Community pharmacists may be able to prescribe asthma medications appropriately to help achieve good outcomes for their patients. However, further training in the guidelines for prescribing are required if pharmacists are to support asthma management in this way. PMID:24644524

  5. Should patients prescribed long-term low-dose aspirin receive proton pump inhibitors? A systematic review and meta-analysis

    NARCIS (Netherlands)

    Tran-Duy, A.; Vanmolkot, F. H.; Joore, M. A.; Hoes, A. W.; Stehouwer, C. D. A.

    2015-01-01

    Background: Several clinical guidelines recommend the use of proton pump inhibitors (PPIs) in patients taking low-dose aspirin but report no or limited supporting data. We conducted a systematic review and meta-analysis to examine the effects of co-administration of PPIs in patients taking low-dose

  6. Is Customization in Antidepressant Prescribing Associated with Acute-Phase Treatment Adherence?

    Science.gov (United States)

    Merrick, Elizabeth L; Hodgkin, Dominic; Panas, Lee; Soumerai, Stephen B; Ritter, Grant

    2012-03-01

    OBJECTIVES: The objective was to explore whether prescribing variation is associated with duration of antidepressant use during the acute phase of treatment. Improving quality of care and increasing the extent to which treatment is patient-centered and customized are interrelated goals. Prescribing variation may be considered a marker of customization, and could be associated with better antidepressant treatment adherence. METHODS: A cross-sectional secondary data analysis examining the association between providers' antidepressant prescribing variation and patient continuity of antidepressant treatment. The data source was two states' Medicaid claims for dual-eligible Medicaid/Medicare patients. The sample included 383 patients with new episodes of antidepressant treatment, representing 70 providers with at least four patients in the sample. We tested two alternate measures of prescribing concentration: 1) share of prescriber's initial antidepressant prescribing accounted for by the two most common regimens, and 2) Herfindahl index. The HEDIS performance measure of effective acute-phase treatment (at least 84 out of 114 days with antidepressant) was the dependent variable. KEY FINDINGS: In multivariate analyses, the concentration measure based on the top two regimens was significant and inversely related to duration adequacy (p customized care.

  7. Staff radiation doses during eight years in a nuclear medicine radiopharmacy

    International Nuclear Information System (INIS)

    Jansen, S.E.; Aswegen, A. van; Loetter, M.G.; Herbst, C.P.; Otto, A.C.; Orange Free State Univ., Bloemfontein

    1994-01-01

    Staff working in the radiopharmacy and nursing staff responsible for injecting radionuclides are being monitored constantly in our department. We report here on the effective doses and doses to the hands received by staff at two hospitals during 8 years from January 1985 to December 1992. In addition to the doses determined monthly by the South African Bureau of Standards' Radiation Protection Service (SABS), radiation doses received to the hands and whole body were measured every week using lithium fluoride thermoluminescent dosimetry (TLD). The highest total radiation dose received in any one year by any one person at hospital A was 233.53 mSv to the hands, and 10.20 mSv and 8.37 mSv to the whole body depending on the dosemeter used. The corresponding values for hospital B were 54.05 mSv to the hands and 6.94 mSv and 4.43 mSv to the whole body. If only one radiographer should do all the work calculated highest dose received would be 447.06 mSv to the hands and 9.68 mSv SABS effective dose. The radiation doses to staff were well within the limits prescribed. (Author)

  8. Differences in antimicrobial consumption, prescribing and isolation rate of multidrug resistant Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii on surgical and medical wards.

    Directory of Open Access Journals (Sweden)

    Vladimir Zivanovic

    Full Text Available In order to provide guidance data for clinically rational use of an antibiotics consuption, prescribing and prevalence of multidrug resistant (MDR Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii were monitored on the surgical (S and medical (M wards of the University Hospital Center "Dr. Dragisa Misovic-Dedinje" (Belgrade, Serbia, in the study period from 2012 to 2015. Appropriateness of antimicrobial use was evaluated using the Global-Prevalence Survey method designed by the University of Antwerp. The percentages of MDR pathogens relative to the total number of isolates of K. pneumoniae and P. aeruginosa were higher on the S (86.2% and 49.1% than on the M (63.2% and 36.9% wards. The percentage of MDR A. baumannii was not different between S (93.7% and M (79.5% wards. An overall antibiotics consumption (defined daily doses/100 bed-days during study was 369.7 and 261.5 on the S and M wards, respectively. A total of 225 prescriptions of antimicrobials were evaluated in138 adults admitted to wards on the day of the survey. The percentage of antimicrobials prescribed for prophylaxis on the M and S wards were 0% and 25%, respectively. Therapies were more frequently empiric (S, 86.8% and M, 80%. The percentages of medical errors on the S and M wards were 74.6% and 27.3%, respectively. The quality indicators for antibiotic prescribing on the S and M wards were as follows: the incorrect choice of antimicrobials (35.6% vs. 20.0%, inappropriate dose interval (70.6% vs. 16.9% or duration of therapy (72.5% vs. 23.1%, a non-documented stop/review data (73.6% vs. 16.9% and divergence from guidelines (71.9% vs. 23.1%. Treatment based on biomarkers was more common on the M wards as compared to the S wards. The increasing prevalence of MDR pathogens, a very high consumption and incorrect prescribing of antimicrobials need special attention, particularly on the S wards.

  9. Vancomycin Utilization Evaluation: Are We Dosing Appropriately?

    Directory of Open Access Journals (Sweden)

    Ladan Ayazkhoo

    2015-10-01

    Full Text Available Background: Inappropriate use of vancomycin not only increase health care costs but also contribute to the emergence of resistant organisms. Higher trough serum vancomycin concentrations (>10mg/L has been recommended for avoidance of development of resistance. We aim to compare the administered dose with recommended doses based on guideline-recommended weight-based dosing.Methods: In a cross sectional study, all patients who received vancomycin between July and October 2013, in infectious disease, internal medicine wards and emergency department of a teaching hospital in Tehran, Iran were entered to the study. Indication of vancomycin and necessary data for dose calculation including height and serum creatinine were recorded. Prescribed doses were compared with recommended doses in guidelines and calculated Glomerular filtration rate (GFR for each patient.Results: One hundred and four patients (45 females and 59 males recruited in the study. Our results indicated that, from all administered doses of vancomycin, 64.4% and 88.8% differs significantly (more than 20% based on American Pharmacist Association (AphA vancomycin monograph and guideline-recommended, weight-based vancomycin dosing (for adults, respectively.Conclusion: Underdosing of vancomycin is a major risk factor for developing resistance of gram positive organisms to this glycopeptide. Our results showed that more than half of patients receiving vancomycin are in the risk of low drug levels based on guidelines. So, having a comprehensive plan for the proper use of this drug especially designing effective internal guidelines can prevent emergence of resistance to vancomycin in future.

  10. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  11. Minimum critical mass systems

    International Nuclear Information System (INIS)

    Dam, H. van; Leege, P.F.A. de

    1987-01-01

    An analysis is presented of thermal systems with minimum critical mass, based on the use of materials with optimum neutron moderating and reflecting properties. The optimum fissile material distributions in the systems are obtained by calculations with standard computer codes, extended with a routine for flat fuel importance search. It is shown that in the minimum critical mass configuration a considerable part of the fuel is positioned in the reflector region. For 239 Pu a minimum critical mass of 87 g is found, which is the lowest value reported hitherto. (author)

  12. US outpatient antibiotic prescribing variation according to geography, patient population, and provider specialty in 2011.

    Science.gov (United States)

    Hicks, Lauri A; Bartoces, Monina G; Roberts, Rebecca M; Suda, Katie J; Hunkler, Robert J; Taylor, Thomas H; Schrag, Stephanie J

    2015-05-01

    Appropriate antibiotic prescribing is an essential strategy to reduce the spread of antibiotic resistance. US prescribing practices have not been thoroughly characterized. We analyzed outpatient antibiotic prescribing data to identify where appropriate antibiotic prescribing interventions could have the most impact. Oral antibiotic prescriptions dispensed during 2011 were extracted from the IMS Health Xponent database. The number of prescriptions and census denominators were used to calculate prescribing rates. Prescription totals were calculated for each provider specialty. Regression modeling was used to examine the association between socioeconomic and population health factors and prescribing rates. Healthcare providers prescribed 262.5 million courses of antibiotics in 2011(842 prescriptions per 1000 persons). Penicillins and macrolides were the most common antibiotic categories prescribed. The most commonly prescribed individual antibiotic agent was azithromycin. Family practitioners prescribed the most antibiotic courses (24%). The prescribing rate was higher in the South census region (931 prescriptions per 1000 persons) than in the West (647 prescriptions per 1000 persons; P 1.0). Efforts to characterize antibiotic prescribing practices should focus on the South census region and family practitioners. Further understanding of the factors leading to high prescribing among key target populations will inform appropriate prescribing interventions. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  13. Comparison of Prescribed and Measured Dialysate Sodium: A Quality Improvement Project.

    Science.gov (United States)

    Gul, Ambreen; Miskulin, Dana C; Paine, Susan S; Narsipur, Sriram S; Arbeit, Leonard A; Harford, Antonia M; Weiner, Daniel E; Schrader, Ronald; Horowitz, Bruce L; Zager, Philip G

    2016-03-01

    There is controversy regarding the optimal dialysate sodium concentration for hemodialysis patients. Dialysate sodium concentrations of 134 to 138 mEq/L may decrease interdialytic weight gain and improve hypertension control, whereas a higher dialysate sodium concentration may offer protection to patients with low serum sodium concentrations and hypotension. We conducted a quality improvement project to explore the hypothesis that prescribed and delivered dialysate sodium concentrations may differ significantly. Cross-sectional quality improvement project. 333 hemodialysis treatments in 4 facilities operated by Dialysis Clinic, Inc. Measure dialysate sodium to assess the relationships of prescribed and measured dialysate sodium concentrations. Magnitude of differences between prescribed and measured dialysate sodium concentrations. Dialysate sodium measured pre- and late dialysis. The least square mean of the difference between prescribed minus measured dialysate sodium concentration was -2.48 (95% CI, -2.87 to -2.10) mEq/L. Clinics with a greater number of different dialysate sodium prescriptions (clinic 1, n=8; clinic 2, n=7) and that mixed dialysate concentrates on site had greater differences between prescribed and measured dialysate sodium concentrations. Overall, 57% of measured dialysate sodium concentrations were within ±2 mEq/L of the prescribed dialysate sodium concentration. Differences were greater at higher prescribed dialysate sodium concentrations. We only studied 4 facilities and dialysate delivery machines from 2 manufacturers. Because clinics using premixed dialysate used the same type of machine, we were unable to independently assess the impact of these factors. Pressures in dialysate delivery loops were not measured. There were significant differences between prescribed and measured dialysate sodium concentrations. This may have beneficial or deleterious effects on clinical outcomes, as well as confound results from studies assessing the

  14. Do final-year medical students have sufficient prescribing competencies? A systematic literature review.

    Science.gov (United States)

    Brinkman, David J; Tichelaar, Jelle; Graaf, Sanne; Otten, René H J; Richir, Milan C; van Agtmael, Michiel A

    2018-04-01

    Prescribing errors are an important cause of patient safety incidents and are frequently caused by junior doctors. This might be because the prescribing competence of final-year medical students is poor as a result of inadequate clinical pharmacology and therapeutic (CPT) education. We reviewed the literature to investigate which prescribing competencies medical students should have acquired in order to prescribe safely and effectively, and whether these have been attained by the time they graduate. PubMed, EMBASE and ERIC databases were searched from the earliest dates up to and including January 2017, using the terms 'prescribing', 'competence' and 'medical students' in combination. Articles describing or evaluating essential prescribing competencies of final-year medical students were included. Twenty-five articles describing, and 47 articles evaluating, the prescribing competencies of final-year students were included. Although there seems to be some agreement, we found no clear consensus among CPT teachers on which prescribing competencies medical students should have when they graduate. Studies showed that students had a general lack of preparedness, self-confidence, knowledge and skills, specifically regarding general and antimicrobial prescribing and pharmacovigilance. However, the results should be interpreted with caution, given the heterogeneity and methodological weaknesses of the included studies. There is considerable evidence that final-year students have insufficient competencies to prescribe safely and effectively, although there is a need for a greater consensus among CPT teachers on the required competencies. Changes in undergraduate CPT education are urgently required in order to improve the prescribing of future doctors. © 2018 VU University Medical Centre. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  15. Nudging guideline-concordant antibiotic prescribing: a randomized clinical trial.

    Science.gov (United States)

    Meeker, Daniella; Knight, Tara K; Friedberg, Mark W; Linder, Jeffrey A; Goldstein, Noah J; Fox, Craig R; Rothfeld, Alan; Diaz, Guillermo; Doctor, Jason N

    2014-03-01

    "Nudges" that influence decision making through subtle cognitive mechanisms have been shown to be highly effective in a wide range of applications, but there have been few experiments to improve clinical practice. To investigate the use of a behavioral "nudge" based on the principle of public commitment in encouraging the judicious use of antibiotics for acute respiratory infections (ARIs). Randomized clinical trial in 5 outpatient primary care clinics. A total of 954 adults had ARI visits during the study timeframe: 449 patients were treated by clinicians randomized to the posted commitment letter (335 in the baseline period, 114 in the intervention period); 505 patients were treated by clinicians randomized to standard practice control (384 baseline, 121 intervention). The intervention consisted of displaying poster-sized commitment letters in examination rooms for 12 weeks. These letters, featuring clinician photographs and signatures, stated their commitment to avoid inappropriate antibiotic prescribing for ARIs. Antibiotic prescribing rates for antibiotic-inappropriate ARI diagnoses in baseline and intervention periods, adjusted for patient age, sex, and insurance status. Baseline rates were 43.5% and 42.8% for control and poster, respectively. During the intervention period, inappropriate prescribing rates increased to 52.7% for controls but decreased to 33.7% in the posted commitment letter condition. Controlling for baseline prescribing rates, we found that the posted commitment letter resulted in a 19.7 absolute percentage reduction in inappropriate antibiotic prescribing rate relative to control (P = .02). There was no evidence of diagnostic coding shift, and rates of appropriate antibiotic prescriptions did not diminish over time. Displaying poster-sized commitment letters in examination rooms decreased inappropriate antibiotic prescribing for ARIs. The effect of this simple, low-cost intervention is comparable in magnitude to costlier, more

  16. [Antibiotic prescribing in acute respiratory tract infections in general practice].

    Science.gov (United States)

    Malo, S; Bjerrum, L; Feja, C; Lallana, M J; Poncel, A; Rabanaque, M J

    2015-06-01

    Antimicrobial resistance is a worldwide threat to public health. Acute respiratory tract infections are the main reason for antibiotic prescribing in the Spanish paediatric population. The aim of the study was to describe the frequency of antibiotic prescription and their pattern of use in acute respiratory tract infections diagnosed in children in Primary Care in Aragón (Spain). A study was conducted over a 1-year period on children between 0 and 14 years-old, recording all episodes of acute otitis, acute pharyngotonsillitis, non-specific upper respiratory infection, and acute bronchitis. The proportion of episodes within each diagnosis receiving an antibiotic prescription was calculated, and the prescribing pattern was determined. Half (50%) of the children in Aragón were diagnosed with a respiratory tract infection during the study period. Non-specific upper respiratory infection was the most frequent diagnosis. An antibiotic was prescribed in 75% of pharyngotonsillitis episodes, 72% of otitis, 27% of bronchitis, and 16% of non-specific upper respiratory infections. Broad spectrum antibiotics, mainly amoxicillin and amoxicillin-clavulanic, were predominantly prescribed. Antibiotic prescribing in respiratory tract infections in children was generally high, and the choice of antibiotics was probably inappropriate in a high percentage of cases. Therefore an improvement in antibiotic prescribing in children appears to be needed. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  17. Prescribed burning in the South: trends, purpose, and barriers

    Science.gov (United States)

    Terry K. Haines; Rodney L. Busby; David A. Cleaves

    2001-01-01

    The results of a survey of fire management officials concerning historical and projected prescribed burning activity in the South are reported. Prescribed burning programs on USDA Forest Service and private and State-owned lands are described in terms of area burned by ownership and State, intended resource benefits, barriers to expanded burning, and optimum burning...

  18. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  19. Generation of uniformly distributed dose points for anatomy-based three-dimensional dose optimization methods in brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Giannouli, S; Milickovic, N; Zamboglou, N

    2000-05-01

    We have studied the accuracy of statistical parameters of dose distributions in brachytherapy using actual clinical implants. These include the mean, minimum and maximum dose values and the variance of the dose distribution inside the PTV (planning target volume), and on the surface of the PTV. These properties have been studied as a function of the number of uniformly distributed sampling points. These parameters, or the variants of these parameters, are used directly or indirectly in optimization procedures or for a description of the dose distribution. The accurate determination of these parameters depends on the sampling point distribution from which they have been obtained. Some optimization methods ignore catheters and critical structures surrounded by the PTV or alternatively consider as surface dose points only those on the contour lines of the PTV. D(min) and D(max) are extreme dose values which are either on the PTV surface or within the PTV. They must be avoided for specification and optimization purposes in brachytherapy. Using D(mean) and the variance of D which we have shown to be stable parameters, achieves a more reliable description of the dose distribution on the PTV surface and within the PTV volume than does D(min) and D(max). Generation of dose points on the real surface of the PTV is obligatory and the consideration of catheter volumes results in a realistic description of anatomical dose distributions.

  20. Indicators of image quality and doses in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2007-01-01

    Full text: The purpose of the study was to determine the values of the image quality indicators and their relationship with the dose in mammography of screen-film that they allowed the detection of a bigger number of objects in the images obtained with the mannequin (phantom) authorized of the ACR/FDA. The study was carried out in four mammography services in a period of 12 months. The indicators of the image quality are the half optic density (DOM), contrast (differences of densities), the number of observed objects in the images and the dose for image. The minimum acceptable values by the ACR/FDA are a half optical density of 1.4, contrast of 0.4 and the one numbers minimum of objects observed in the image of the mannequin of mammography of 10 (4 fibers, 3 groups of calcifications and 3 masses), with a maximum dose by image of 3 mGy. The found results are half optical density of 1.9, contrast of 0.56 and the average number of objects observed in the images of 12, with a dose in the interval of 1.6 mGy to 2.4 mGy. The doses were measured by thermoluminescent dosimetry and ionization chamber. Once carried out the analysis of the tendencies of the indicators of image quality and their distributions is found that for a p < 0.05, the bigger number of objects observed in the images is in the interval from 1.8 to 1.9 of DOM. When comparing both mammography system, the system screen-film has a lower variability in the distribution of objects associated to a DOM. (Author)