WorldWideScience

Sample records for minimal erythemal dose

  1. A Semiempirical Approach to the Determination of Daily Erythemal Doses.

    Science.gov (United States)

    Silva, Abel A; Yamamoto, Ana L C; Corrêa, Marcelo P

    2018-02-15

    The maintenance of ground-based instruments to measure the incidence of ultraviolet radiation (UVR) from the Sun demands strict and well-developed procedures. A piece of equipment can be out of service for a couple of weeks or months for calibration, repair or even the improvement of the facilities where it has been set up. However, the replacement of an instrument in such circumstances can be logistically and financially prohibitive. On the other hand, the lack of data can jeopardize a long-term experiment. In this study, we introduce a semiempirical approach to the determination of the theoretical daily erythemal dose (DED t ) for periods of instrumental absence in a tropical site. The approach is based on 5 years of ground-based measurements of daily erythemal dose (DED) linearly correlated with parameters of total ozone column (TOC) and reflectivity (R PC ) from the Ozone Monitoring Instrument (OMI) and the cosine of solar zenith angle at noon (SZA n ). Seventeen months of missing ground-based data were replaced with DED t , leading to a complete 5-year series of data. The lowest and the highest values of typical DED were 2411 ± 322 J m -2 (1σ) (winter) and 5263 ± 997 J m -2 (summer). The monthly integrated erythemal dose (mED) varied from 59 kJ m -2 (winter) to 162 kJ m -2 (summer). Both of them depended mainly on cos(SZA n ) and R PC . The 12-month integrated erythemal dose (12-ED) ranged from 1350 kJ m -2 to 1546 kJ m -2 , but it can depend significantly on other atmospheric parameter (maybe aerosols) not explicitly considered here. © 2018 The American Society of Photobiology.

  2. Erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA

    International Nuclear Information System (INIS)

    Speight, E.L.; Farr, P.M.

    1994-01-01

    In PUVA treatment of psoriasis, clinical observation suggests that uninvolved skin is more susceptible to PUVA erythema than lesions of psoriasis. If this is the case, then the efficacy of PUVA treatment might be increased by using localized high-dose UVA restricted to lesional skin. We have therefore studied the erythemal and therapeutic response of psoriasis to PUVA using high-dose UVA and, for comparison, the erythemal response to UVB. This study demonstrates that psoriasis may clear rapidly, without burning, using high-dose UVA. Availability of a suitable irradiation apparatus would allow rapid and effective PUVA treatment to be used for localized, resistant disease. (author)

  3. Validation of OMI erythemal doses with multi-sensor ground-based measurements in Thessaloniki, Greece

    Science.gov (United States)

    Zempila, Melina Maria; Fountoulakis, Ilias; Taylor, Michael; Kazadzis, Stelios; Arola, Antti; Koukouli, Maria Elissavet; Bais, Alkiviadis; Meleti, Chariklia; Balis, Dimitrios

    2018-06-01

    The aim of this study is to validate the Ozone Monitoring Instrument (OMI) erythemal dose rates using ground-based measurements in Thessaloniki, Greece. In the Laboratory of Atmospheric Physics of the Aristotle University of Thessaloniki, a Yankee Environmental System UVB-1 radiometer measures the erythemal dose rates every minute, and a Norsk Institutt for Luftforskning (NILU) multi-filter radiometer provides multi-filter based irradiances that were used to derive erythemal dose rates for the period 2005-2014. Both these datasets were independently validated against collocated UV irradiance spectra from a Brewer MkIII spectrophotometer. Cloud detection was performed based on measurements of the global horizontal radiation from a Kipp & Zonen pyranometer and from NILU measurements in the visible range. The satellite versus ground observation validation was performed taking into account the effect of temporal averaging, limitations related to OMI quality control criteria, cloud conditions, the solar zenith angle and atmospheric aerosol loading. Aerosol optical depth was also retrieved using a collocated CIMEL sunphotometer in order to assess its impact on the comparisons. The effect of total ozone columns satellite versus ground-based differences on the erythemal dose comparisons was also investigated. Since most of the public awareness alerts are based on UV Index (UVI) classifications, an analysis and assessment of OMI capability for retrieving UVIs was also performed. An overestimation of the OMI erythemal product by 3-6% and 4-8% with respect to ground measurements is observed when examining overpass and noontime estimates respectively. The comparisons revealed a relatively small solar zenith angle dependence, with the OMI data showing a slight dependence on aerosol load, especially at high aerosol optical depth values. A mean underestimation of 2% in OMI total ozone columns under cloud-free conditions was found to lead to an overestimation in OMI erythemal

  4. Proxy-based reconstruction of erythemal UV doses over Estonia for 1955–2004

    Directory of Open Access Journals (Sweden)

    K. Eerme

    2006-08-01

    Full Text Available A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l. site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle. In 1998–2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002. Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2–4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955–2004 were found to be within 92–111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95–105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976–1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955–2004 average. Since 1996/1997 midwinters have been darker than on average.

  5. Proxy-based reconstruction of erythemal UV doses over Estonia for 1955–2004

    Directory of Open Access Journals (Sweden)

    K. Eerme

    2006-08-01

    Full Text Available A proxy-based reconstruction of the erythemally-weighted UV doses for 1955-2004 has been performed for the Tartu-Tõravere Meteorological Station (58°16' N, 26°28' E, 70 m a.s.l. site. The pyrheliometer-measured daily sum of direct irradiance on partly cloudy and clear days, and the pyranometer-measured daily sum of global irradiance on overcast days were used as the cloudiness influence related proxies. The TOMS ozone data have been used for detecting the daily deviations from the climatic value (averaged annual cycle. In 1998–2004, the biases between the measured and reconstructed daily doses in 55.5% of the cases were within ±10% and in 83.5% of the cases within ±20%, on average. In the summer half-year these amounts were 62% and 88%, respectively. In most years the results for longer intervals did not differ significantly, if no correction was made for the daily deviations of total ozone from its climatic value. The annual and summer half-yearly erythemal doses (contributing, on average, 89% of the annual value agreed within ±2%, except for the years after major volcanic eruptions and one extremely fine weather year (2002. Using the daily relative sunshine duration as a proxy without detailed correction for atmospheric turbidity results in biases of 2–4% in the summer half-yearly dose in the years after major volcanic eruptions and a few other years of high atmospheric turbidity. The year-to-year variations of the summer half-yearly erythemal dose in 1955–2004 were found to be within 92–111% relative to their average value. Exclusion of eight extreme years reduces this range for the remaining to 95–105.5%. Due to the quasi-periodic alternation of wet and dry periods, the interval of cloudy summers 1976–1993 regularly manifests summer half-yearly erythemal dose values lower than the 1955–2004 average. Since 1996/1997 midwinters have been darker than on average.

  6. Reconstruction of erythemal UV-doses for two stations in Austria: a comparison between alpine and urban regions

    Directory of Open Access Journals (Sweden)

    H. E. Rieder

    2008-10-01

    Full Text Available The aim of this study is the reconstruction of past UV-doses for two stations in Austria, Hoher Sonnblick and Vienna, using a physical radiation transfer model. The method uses the modeled UV-dose under clear-sky conditions, cloud modification factors and a correction factor as input variables. To identify the influence of temporal resolution of input data and modification factors, an ensemble of four different modelling approaches was calculated, each with hourly or daily resolution. This is especially important because we found no other study describing the influence of the temporal resolution of input data on model performance. Following the results of the statistical analysis of the evaluation period the model with the highest temporal resolution (HMC was chosen for the reconstruction of UV-doses. A good agreement between modelled and measured values of erythemally effective UV-doses was found at both stations. In relation to the reference period 1976–1985 an increase in the erythemal UV-dose in Vienna of 11% is visible in the period 1986–1995 and an increase of 17% in the period 1996–2005 can be seen. At Hoher Sonnblick the corresponding increase is 2% and 9%. For the different seasons the strongest increase in erythemal UV-dose has been found for winter and spring season at both stations. Further the influences of total ozone and cloudiness on changes in erythemal UV-doses were analyzed. This analysis showed for both stations, that changes in total ozone had a larger influence on erythemal UV-doses than changes in cloudiness.

  7. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version 003 of Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose Level-2G data product (Daily level-2 data binned into global 0.25 deg Lat/Lon grids)...

  8. Influence of solar UVA on erythemal irradiances

    International Nuclear Information System (INIS)

    Parisi, A V; Turnbull, D J; Kimlin, M G

    2006-01-01

    Many materials in everyday use such as window glass in homes and offices, glass in sunrooms and greenhouses, vehicle glass and some brands of sunscreens act as a barrier to the shorter UVB wavelengths while transmitting some of the longer UVA wavelengths. This paper reports on the erythemal exposures due to the UVA waveband encountered over a 12-month period for a solar zenith angle (SZA) range of 4 0 to 80 0 and the resulting times required for an erythemal exposure of one standard erythemal dose (SED) due to the erythemal exposures to the UVA wavelengths. The minimum time for an exposure of one SED due to the UVA wavelengths in winter is approximately double that what it is in summer. The time period of 40 to 60 min was the most frequent length of time for an exposure of one SED with 60 to 80 min the next frequent length of time required for a one SED exposure

  9. Erythemal solar UV measurement network in New Zealand

    International Nuclear Information System (INIS)

    Smith, G.J.

    1993-01-01

    Measured daily total erythemal doses for 1989, 1990 and 1991 were presented and the cloudless-sky daily dose at the autumn equinox was approximately 30-50% higher than at the spring equinox as a result of the seasonal variation in ozone levels. In addition a substantially lower spring equinox erythemal dose was observed in 1991, probably as a result of increased aerosols arising from the Pinatubo eruption. An asymmetry in the diurnal pattern of irradiances about solar noon has been observed on cloudless days. Higher UV irradiances have been usually observed in the afternoons than in the mornings. Measurement of erythemal radiation is needed for skin cancer epidemiology projects. Given the uncertainties relating to the exposure of individuals to solar erythemal radiation, personal dosimeters may be very useful in providing more reliable personal UV exposure data. (author). 4 refs

  10. Reconstruction of the erythemal UV radiation data in Novi Sad (Serbia) using the NEOPLANTA parametric model

    Science.gov (United States)

    Malinovic-Milicevic, S.; Mihailovic, D. T.; Radovanovic, M. M.

    2015-07-01

    This paper focuses on the development and application of a technique for filling the daily erythemal UV dose data gaps and the reconstruction of the past daily erythemal UV doses in Novi Sad, Serbia. The technique implies developing the empirical equation for estimation of daily erythemal UV doses by means of relative daily sunshine duration under all sky conditions. A good agreement was found between modeled and measured values of erythemal UV doses. This technique was used for filling the short gaps in the erythemal UV dose measurement series (2003-2009) as well as for the reconstruction of the past time-series values (1981-2002). Statistically significant positive erythemal UV dose trend of 6.9 J m-2 per year was found during the period 1981-2009. In relation to the reference period 1981-1989, an increase in the erythemal UV dose of 6.92 % is visible in the period 1990-1999 and the increase of 9.67 % can be seen in the period 2000-2009. The strongest increase in erythemal UV doses has been found for winter and spring seasons.

  11. Solar UV radiation exposure of seamen - Measurements, calibration and model calculations of erythemal irradiance along ship routes

    Energy Technology Data Exchange (ETDEWEB)

    Feister, Uwe [German Meteorological Service, Meteorological Observatory Lindenberg - Richard-Assmann-Observatory, Am Observatorium 12, 15848 Lindenberg (Germany); Meyer, Gabriele; Kirst, Ulrich [German Social Accident Insurance Institution for Transport and Traffic, Ottenser Hauptstrasse 54, 22765 Hamburg (Germany)

    2013-05-10

    Seamen working on vessels that go along tropical and subtropical routes are at risk to receive high doses of solar erythemal radiation. Due to small solar zenith angles and low ozone values, UV index and erythemal dose are much higher than at mid-and high latitudes. UV index values at tropical and subtropical Oceans can exceed UVI = 20, which is more than double of typical mid-latitude UV index values. Daily erythemal dose can exceed the 30-fold of typical midlatitude winter values. Measurements of erythemal exposure of different body parts on seamen have been performed along 4 routes of merchant vessels. The data base has been extended by two years of continuous solar irradiance measurements taken on the mast top of RV METEOR. Radiative transfer model calculations for clear sky along the ship routes have been performed that use satellite-based input for ozone and aerosols to provide maximum erythemal irradiance and dose. The whole data base is intended to be used to derive individual erythemal exposure of seamen during work-time.

  12. A radioisotope production cyclotron designed to minimize dose

    International Nuclear Information System (INIS)

    Szlavik, F.F.; Moritz, L.E.

    1992-01-01

    This paper describes a radioisotope production cyclotron which has been designed to minimize the dose to personnel during operation and maintenance. The design incorporates lessons learned from the operation of a CP42 cyclotron and has resulted in a reduction of the dose by a factor of more than 10. (author)

  13. The minimal melanogenesis dose/minimal erythema dose ratio declines with increasing skin pigmentation using solar simulator and narrowband ultraviolet B exposure

    DEFF Research Database (Denmark)

    Ravnbak, Mette H; Philipsen, Peter A; Wulf, Hans Christian

    2010-01-01

    To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure.......To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure....

  14. Affordable CZT SPECT with dose-time minimization (Conference Presentation)

    Science.gov (United States)

    Hugg, James W.; Harris, Brian W.; Radley, Ian

    2017-03-01

    PURPOSE Pixelated CdZnTe (CZT) detector arrays are used in molecular imaging applications that can enable precision medicine, including small-animal SPECT, cardiac SPECT, molecular breast imaging (MBI), and general purpose SPECT. The interplay of gamma camera, collimator, gantry motion, and image reconstruction determines image quality and dose-time-FOV tradeoffs. Both dose and exam time can be minimized without compromising diagnostic content. METHODS Integration of pixelated CZT detectors with advanced ASICs and readout electronics improves system performance. Because historically CZT was expensive, the first clinical applications were limited to small FOV. Radiation doses were initially high and exam times long. Advances have significantly improved efficiency of CZT-based molecular imaging systems and the cost has steadily declined. We have built a general purpose SPECT system using our 40 cm x 53 cm CZT gamma camera with 2 mm pixel pitch and characterized system performance. RESULTS Compared to NaI scintillator gamma cameras: intrinsic spatial resolution improved from 3.8 mm to 2.0 mm; energy resolution improved from 9.8% to reconstruction, result in minimized dose and exam time. With CZT cost improving, affordable whole-body CZT general purpose SPECT is expected to enable precision medicine applications.

  15. Minimal doses of hydroxyurea for sickle cell disease

    Directory of Open Access Journals (Sweden)

    C.S.P. Lima

    1997-08-01

    Full Text Available The use of hydroxyurea (HU can improve the clinical course of sickle cell disease. However, several features of HU treatment remain unclear, including the predictability of drug response and determination of adequate doses, considering positive responses and minimal side effects. In order to identify adequate doses of HU for treatment of sickle cell disease, 10 patients, 8 with sickle cell anemia and 2 with Sß thalassemia (8SS, 2Sß, were studied for a period of 6 to 19 months in an open label dose escalation trial (10 to 20 mg kg-1 day-1. Hemoglobin (Hb, fetal hemoglobin (Hb F and mean corpuscular volume (MCV values and reticulocyte, neutrophil and platelet counts were performed every two weeks during the increase of the HU dose and every 4 weeks when the maximum HU dose was established. Reduction in the number of vasoocclusive episodes was also considered in order to evaluate the efficiency of the treatment. The final Hb and Hb F concentrations, and MCV values were significantly higher than the initial values, while the final reticulocyte and neutrophil counts were significantly lower. There was an improvement in the concentration of Hb (range: 0.7-2.0 g/dl at 15 mg HU kg-1 day-1, but this concentration did not increase significantly when the HU dose was raised to 20 mg kg-1 day-1. The concentration of Hb F increased significantly (range: 1.0-18.1% when 15 mg HU was used, and continued to increase when the dose was raised to 20 mg kg-1 day-1. The final MCV values increased 11-28 fl (femtoliters. However, reticulocyte (range: 51-205 x 109/l and neutrophil counts (range: 9.5-1.3 x 109/l obtained at this dose were significantly lower than those obtained with 15 mg kg-1 day-1. All patients reported a decrease in frequency or severity of vasoocclusive episodes. These results suggest that a hydroxyurea dose of 15 mg kg-1 day-1 seems to be adequate for treatment of sickle cell disease in view of the minimal side effects observed and the improvement

  16. Minimizing and measuring lens dose when giving cranial irradiation

    International Nuclear Information System (INIS)

    Woo, S.Y.; Donaldson, S.S.; Heck, R.J.; Nielson, K.L.; Shostak, C.

    1989-01-01

    Three different techniques of administering cranial irradiation were used to determine the dose to the lens as measured in the Rando phantom. The techniques employed were as follows: (1) the central axis of the radiation beam was placed at the thickest portion of the cranium; (2) the central axis of the radiation beam was placed at the lateral orbital rim (bon canthus); (3) the central axis of the radiation beam was placed at the thickest portion of the cranium but with the beam angled 5deg posteriorly away from the eye. Thermal luminescent dosimeters (TLD) were placed in a phantom, at a point determined from a life-sized anatomical section of the plane through the midsection of the eye, to be at the location of the posterior capsule of the lens. In addition, TLDs were placed on the outer surface of the phantom head, directly lateral to the location determined to be where the lens would lie. With equally weighted lateral opposed beams, delivering a midplane dose of 200cGy, the TLDs at the point of the lens measured 21, 9.9 and 10.6% of the midplane doses from the three techniques respectively. TLDs placed directly lateral to the lens on the surface of the phantom head gave an approximation of the lens dose, particularly when techniques 2 and 3 were used. Isodose curve generated by a General Electric treatment planning computer gave lens doses similar to those of the phantom data for each of the three different radiotherapy techniques. Cranial irradiation should be carried out by either technique 2 or technique 3 to minimize radiation dose to the lens. (author). 11 refs.; 2 figs.; 3 tabs

  17. Dose-mass inverse optimization for minimally moving thoracic lesions

    Science.gov (United States)

    Mihaylov, I. B.; Moros, E. G.

    2015-05-01

    In the past decade, several different radiotherapy treatment plan evaluation and optimization schemes have been proposed as viable approaches, aiming for dose escalation or an increase of healthy tissue sparing. In particular, it has been argued that dose-mass plan evaluation and treatment plan optimization might be viable alternatives to the standard of care, which is realized through dose-volume evaluation and optimization. The purpose of this investigation is to apply dose-mass optimization to a cohort of lung cancer patients and compare the achievable healthy tissue sparing to that one achievable through dose-volume optimization. Fourteen non-small cell lung cancer (NSCLC) patient plans were studied retrospectively. The range of tumor motion was less than 0.5 cm and motion management in the treatment planning process was not considered. For each case, dose-volume (DV)-based and dose-mass (DM)-based optimization was performed. Nine-field step-and-shoot IMRT was used, with all of the optimization parameters kept the same between DV and DM optimizations. Commonly used dosimetric indices (DIs) such as dose to 1% the spinal cord volume, dose to 50% of the esophageal volume, and doses to 20 and 30% of healthy lung volumes were used for cross-comparison. Similarly, mass-based indices (MIs), such as doses to 20 and 30% of healthy lung masses, 1% of spinal cord mass, and 33% of heart mass, were also tallied. Statistical equivalence tests were performed to quantify the findings for the entire patient cohort. Both DV and DM plans for each case were normalized such that 95% of the planning target volume received the prescribed dose. DM optimization resulted in more organs at risk (OAR) sparing than DV optimization. The average sparing of cord, heart, and esophagus was 23, 4, and 6%, respectively. For the majority of the DIs, DM optimization resulted in lower lung doses. On average, the doses to 20 and 30% of healthy lung were lower by approximately 3 and 4%, whereas lung

  18. Minimalism

    CERN Document Server

    Obendorf, Hartmut

    2009-01-01

    The notion of Minimalism is proposed as a theoretical tool supporting a more differentiated understanding of reduction and thus forms a standpoint that allows definition of aspects of simplicity. This book traces the development of minimalism, defines the four types of minimalism in interaction design, and looks at how to apply it.

  19. A cyclotron isotope production facility designed to maximize production and minimize radiation dose

    International Nuclear Information System (INIS)

    Dickie, W.J.; Stevenson, N.R.; Szlavik, F.F.

    1993-01-01

    Continuing increases in requirements from the nuclear medicine industry for cyclotron isotopes is increasing the demands being put on an aging stock of machines. In addition, with the 1990 recommendations of the ICRP publication in place, strict dose limits will be required and this will have an effect on the way these machines are being operated. Recent advances in cyclotron design combined with lessons learned from two decades of commercial production mean that new facilities can result in a substantial charge on target, low personnel dose, and minimal residual activation. An optimal facility would utilize a well engineered variable energy/high current H - cyclotron design, multiple beam extraction, and individual target caves. Materials would be selected to minimize activation and absorb neutrons. Equipment would be designed to minimize maintenance activities performed in high radiation fields. (orig.)

  20. Planning of optimal work path for minimizing exposure dose during radiation work in radwaste storage

    International Nuclear Information System (INIS)

    Kim, Yoon Hyuk; Park, Won Man; Kim, Kyung Soo; Whang, Joo Ho

    2005-01-01

    Since the safety of nuclear power plant has been becoming a big social issue, the exposure dose of radiation for workers has been one of the important factors concerning the safety problem. The existing calculation methods of radiation dose used in the planning of radiation work assume that dose rate dose not depend on the location within a work space, thus the variation of exposure dose by different work path is not considered. In this study, a modified numerical method was presented to estimate the exposure dose during radiation work in radwaste storage considering the effects of the distance between a worker and sources. And a new numerical algorithm was suggested to search the optimal work path minimizing the exposure dose in pre-defined work space with given radiation sources. Finally, a virtual work simulation program was developed to visualize the exposure dose of radiation during radiation works in radwaste storage and provide the capability of simulation for work planning. As a numerical example, a test radiation work was simulated under given space and two radiation sources, and the suggested optimal work path was compared with three predefined work paths. The optimal work path obtained in the study could reduce the exposure dose for the given test work. Based on the results, the developed numerical method and simulation program could be useful tools in the planning of radiation work

  1. [Optimizing staff radiation protection in radiology by minimizing the effective dose].

    Science.gov (United States)

    von Boetticher, H; Lachmund, J; Hoffmann, W; Luska, G

    2006-03-01

    In the present study the optimization of radiation protection devices is achieved by minimizing the effective dose of the staff members since the stochastic radiation effects correlate to the effective dose. Radiation exposure dosimetry was performed with TLD measurements using one Alderson Phantom in the patient position and a second phantom in the typical position of the personnel. Various types of protective clothing as well as fixed shields were considered in the calculations. It was shown that the doses of the unshielded organs (thyroid, parts of the active bone marrow) contribute significantly to the effective dose of the staff. Therefore, there is no linear relationship between the shielding factors for protective garments and the effective dose. An additional thyroid protection collar reduces the effective dose by a factor of 1.7 - 3.0. X-ray protective clothing with a 0.35 mm lead equivalent and an additional thyroid protection collar provides better protection against radiation than an apron with a 0.5 mm lead equivalent but no collar. The use of thyroid protection collars is an effective preventive measure against exceeding occupational organ dose limits, and a thyroid shield also considerably reduces the effective dose. Therefore, thyroid protection collars should be a required component of anti-X protection.

  2. Determination method of inactivating minimal dose of gama radiation for Salmonella typhimurium

    International Nuclear Information System (INIS)

    Araujo, E.S.; Campos, H. de; Silva, D.M.

    1979-01-01

    A method for determination of minimal inactivating dose (MID) with Salmonella typhimurium is presented. This is a more efficient way to improve the irradiated vaccines. The MID found for S. thyphimurium 6.616 by binomial test was 0.55 MR. The method used allows to get a definite value for MID and requires less consumption of material, work and time in comparison with the usual procedure [pt

  3. Linezolid Dose That Maximizes Sterilizing Effect While Minimizing Toxicity and Resistance Emergence for Tuberculosis.

    Science.gov (United States)

    Srivastava, Shashikant; Magombedze, Gesham; Koeuth, Thearith; Sherman, Carleton; Pasipanodya, Jotam G; Raj, Prithvi; Wakeland, Edward; Deshpande, Devyani; Gumbo, Tawanda

    2017-08-01

    Linezolid has an excellent sterilizing effect in tuberculosis patients but high adverse event rates. The dose that would maximize efficacy and minimize toxicity is unknown. We performed linezolid dose-effect and dose-scheduling studies in the hollow fiber system model of tuberculosis (HFS-TB) for sterilizing effect. HFS-TB units were treated with several doses to mimic human-like linezolid intrapulmonary pharmacokinetics and repetitively sampled for drug concentration, total bacterial burden, linezolid-resistant subpopulations, and RNA sequencing over 2 months. Linezolid-resistant isolates underwent whole-genome sequencing. The expression of genes encoding efflux pumps in the first 1 to 2 weeks revealed the same exposure-response patterns as the linezolid-resistant subpopulation. Linezolid-resistant isolates from the 2nd month of therapy revealed mutations in several efflux pump/transporter genes and a LuxR-family transcriptional regulator. Linezolid sterilizing effect was linked to the ratio of unbound 0- to 24-h area under the concentration-time curve (AUC 0-24 ) to MIC. Optimal microbial kill was achieved at an AUC 0-24 /MIC ratio of 119. The optimal sterilizing effect dose for clinical use was identified using Monte Carlo simulations. Clinical doses of 300 and 600 mg/day (or double the dose every other day) achieved this target in 87% and >99% of 10,000 patients, respectively. The susceptibility breakpoint identified was 2 mg/liter. The simulations identified that a 300-mg/day dose did not achieve AUC 0-24 s associated with linezolid toxicity, while 600 mg/day achieved those AUC 0-24 s in linezolid dose of 300 mg/day performed well and should be compared to 600 mg/day or 1,200 mg every other day in clinical trials. Copyright © 2017 Srivastava et al.

  4. Minimal infectious doses and prepatent periods in Giardia muris, Spironucleus muris and Tritrichomonas muris.

    Science.gov (United States)

    Stachan, R; Kunstýr, I

    1983-12-01

    The minimal infectious doses (MID) of Giardia muris cysts, Spironucleus muris cysts and Tritrichomonas muris pseudocysts for athymic mice were determined. A novel micromanipulator-aided technique was developed for selecting small exact numbers of specified fresh or old cysts/pseudocysts from a faecal homogenate. This technique can also be of value in manipulating protozoan parasites of any particular species. Only fresh cysts/pseudocysts, which appeared bright under phase contrast optics, were infectious. Older cysts and pseudocysts which appeared dark in phase contrast were not infectious. The MID for three murine intestinal flagellates addressed above were: 10 (between 5 and 20), 1 and 5 cysts/pseudocysts respectively. Corresponding prepatent periods (PP) were 8, 5 and 10 days. A relation was evident between the infectious dose and the PP: The prepatent period shortened with an increased infectious dose.

  5. Cost minimization analysis of high-dose-rate versus low-dose-rate brachytherapy in endometrial cancer

    International Nuclear Information System (INIS)

    Pinilla, James

    1998-01-01

    Purpose: Endometrial cancer is a common, usually curable malignancy whose treatment frequently involves low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy. These treatments involve substantial resource commitments and this is increasingly important. This paper presents a cost minimization analysis of HDR versus LDR brachytherapy in the treatment of endometrial cancer. Methods and Materials: The perspective of the analysis is that of the payor, in this case the Ministry of Health. One course of LDR treatment is compared to two courses of HDR treatment. The two alternatives are considered to be comparable with respect to local control, survival, and toxicities. Labor, overhead, and capital costs are accounted for and carefully measured. A 5% inflation rate is used where applicable. A univariate sensitivity analysis is performed. Results: The HDR regime is 22% less expensive compared to the LDR regime. This is $991.66 per patient or, based on the current workload of this department (30 patients per year) over the useful lifetime of the after loader, $297,498 over 10 years in 1997 dollars. Conclusion: HDR brachytherapy minimizes costs in the treatment of endometrial cancer relative to LDR brachytherapy. These results may be used by other centers to make rational decisions regarding brachytherapy equipment replacement or acquisition

  6. Minimization of the occupational doses during the liquidation of the radiation accident consequences

    International Nuclear Information System (INIS)

    Kuryndina, Lidia; Stroganov, Anatoly; Kuryndin, Anton

    2008-01-01

    Full text: As known the accident on the Chernobylskaya npp is the heaviest one in the nuclear energy history. It showed how considerable can be radiation levels on the breakdown nuclear facility. Nevertheless Russian specialists on radiation protection worked out and successfully realized a conception of the working in such conditions during the liquidation of the accident consequences. The conception based out on using ALARA principle, included the methods of radiation fields structure analysis and allowed to minimize of the occupational doses at operations of the accident consequences liquidation. The main idea of the conception is in strongly dependence between the radiation dose of the personnel performing the liquidation operations and concrete sequence of these operations. Also it is necessary from time to time to receive the experimental information about radiation situation dynamics on the breakdown facility and to make variant calculations for optimizing for the successful implementation of such approach. The structure of these calculations includes variable fraction for the actual state of the facility before the accident and after one and not variable fraction depend on the geometric and protection characteristics of the facility. And the second part is more complicated and bigger. Therefore the most part of these calculations required for the any successful liquidation of the accident consequences can be made on the facility projecting stage. If it will be made the following tasks can be solved in case of the accident: 1) To estimate a distribution of the contamination source using the radiation control system indications; 2) To determine a contribution from each source to the dose rate for any contaminated area; 3) To estimate the radiation doses of the personnel participated in the accident consequences liquidation; 4) To select and to realize the sequence of the liquidation operations giving the minimal doses. The paper will overview the description

  7. Measurement of the thyroid's iodine absorption utilizing minimal /sup 131/I dose

    Energy Technology Data Exchange (ETDEWEB)

    Paz A, B.; Villegas A, J.; Delgado B, C. (Universidad Nacional San Agustin de Arequipa (Peru). Departamento de Bioquimica)

    1981-03-01

    We utilize a minimal dose of /sup 131/I thus limiting the contact of the thyroid tissues with the isotopic materials to determine the absorption of /sup 131/I by the thyroid from 6 to 24 hours in 90 pupils of the locality of Arequipa. The average rate of absorption in 6 and 24 hours in the case considered are of 24.15% and 35.42% respectively, with a standard deviation of 6.93% and 9.61%. No significant differences were reported from the results of those of adults and our own results in all the probes which were undertaken.

  8. Proposed experiments for assessing the potential use of skin as an indicator of sub-erythemal radiation exposure

    International Nuclear Information System (INIS)

    Wells, J.; Charles, M.W.

    1979-08-01

    Several biological systems have been developed in recent years for radiation dosimetry. They have proved to be useful in accident situations or when the result of personal dosemeter assessment is equivocal. A review of a range of biochemical and biophysical dosimetry techniques indicates that none are ideally suited for dose assessment in the sub-erythemal range (< 2 Gy) when a high non-uniform or partial body exposure is involved. This important practical situation could be met by the development of a biological dosimetry system based upon the response of skin. A programme of study has been agreed upon to investigate this possibility. A resume of a 1 year pilot study supported by the CEGB is presented, the results of which will be described in due course. (author)

  9. Determination of the minimal phototoxic dose and colorimetry in psoralen plus ultraviolet A radiation therapy.

    Science.gov (United States)

    Kraemer, Cristine Kloeckner; Menegon, Dóris Baratz; Cestari, Tania Ferreira

    2005-10-01

    The use of an adequate initial dose of ultraviolet A (UVA) radiation for photochemotherapy is important to prevent burns secondary to overdosage, meanwhile avoiding a reduced clinical improvement and long-term risks secondary to underdosage. The ideal initial dose of UVA can be achieved based on the phototype and the minimal phototoxic dose (MPD). The objective measurement of constitutive skin color (colorimetry) is another method commonly used to quantify the erythematous skin reaction to ultraviolet radiation exposure. The aim of this study was to determine variations in MPD and constitutional skin color (coordinate L(*)) within different phototypes in order to establish the best initial dose of UVA radiation for photochemotherapy patients. Thirty-six patients with dermatological conditions and 13 healthy volunteers were divided into five groups according to phototype. Constitutional skin color of the infra-axillary area was assessed by colorimetry. The infra-axillary area was subsequently divided into twelve 1.5 cm(2) regions to determine the MPD; readings were performed 72 h after oral administration of 8-methoxypsoralen (MOP) followed by exposure of the demarcated regions to increasing doses of UVA. The majority of the participants were women (73.5%) and their mean age was 38.8 years. The MPD ranged from 4 to 12 J/cm(2) in phototypes II and III; from 10 to 18 J/cm(2) in type IV; from 12 to 24 J/cm(2) in type V and from 18 to 32 J/cm(2) in type VI. The analysis of colorimetric values (L(*) coordinate) and MPD values allowed the definition of three distinctive groups of individuals composed by phototypes II and III (group 1), types IV and V (group 2), and phototype VI (group 3). MPD and L(*) coordinate showed variation within the same phototype and superposition between adjacent phototypes. The values of the L(*) coordinate and the MPD lead to the definition of three distinct sensitivity groups: phototypes II and III, IV and V and type VI. Also, the MPD values

  10. The facial distribution of erythemal ultraviolet exposure in south-east Queensland

    International Nuclear Information System (INIS)

    Kimlin, M.G.; Parisi, A.V.; Wong, J.C.F.

    1998-01-01

    This paper presents a method for the evaluation of the distribution of the facial erythemal UV exposure and the erythemal UV exposure per unit area of the face using only eight dosimeters located on the vertex of the head, forehead, nose, chin, left and right ears and left and right cheeks. An overall picture of the parts of the face receiving high UV exposures is provided. The distribution of the erythemal UV exposure to the human face at a subtropical latitude was shown to change with time of year and with cloud cover. On two days with similar solar zenith angles, the ratio of the erythemal UV exposure to the nose compared with that on a horizontal plane changed from 0.47 to 0.84 with increased cloud cover. At the same time, the total erythemal exposure per unit area of the face dropped from 122 to 56 mJ cm -2 . Although the absolute exposures decreased, the nose received a relatively high exposure. (author)

  11. The Evaluation of Minimal Erythema Dose For Narrowband UVB in Patients Receiving Isotretinoin Treatment

    Directory of Open Access Journals (Sweden)

    Tuba Çetiner

    2012-09-01

    Full Text Available Background and Design: Although photosensitivity is considered as one of the side effects of retinoids, there is no consensus on this issue. In this study, we aimed to evaluate the minimal erythema dose (MED for narrowband ultraviolet B in patients receiving isotretinoin treatmentMaterial and Method: Phototesting was done by narrowband ultraviolet B irradiation on fifty patients for whom isotretinoin treatment was planned. MED values were calculated before treatment (MED1 and during treatment after reaching half of the target dose (kgx120 mg (MED2, and it was evaluated whether there was statistically significant difference between the two MED values. In addition, the patients were assessed according to their skin phototypes in this respect. Results: When the mean values of MED1 and MED2 were compared in all patients who were treated with 0.5-0.7 mg/kg/day isotretinoin, the mean of MED2 values was found to be lower than the mean of MED1 values. Clinically, sunburn erythema was seen in only 3 (6% patients during the treatment. When the patients were evaluated according to their skin phototypes, significant difference between the means of MED 1 and MED 2 values was not determined. Conclusion: Although isotretinoin treatment does not cause clinically sunburn erythema, it was associated with decrease in MED values.

  12. Radiation Exposure During Uterine Artery Embolization: Effective Measures to Minimize Dose to the Patient

    Energy Technology Data Exchange (ETDEWEB)

    Scheurig-Muenkler, Christian, E-mail: christian.scheurig@charite.de [Charité Universitaetsmedizin Berlin, Department of Diagnostic and Interventional Radiology (Germany); Powerski, Maciej J., E-mail: maciej.powerski@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Mueller, Johann-Christoph, E-mail: johann-christoph.mueller@charite.de [Charité Universitaetsmedizin Berlin, Department of Diagnostic and Interventional Radiology (Germany); Kroencke, Thomas J., E-mail: Thomas.Kroencke@klinikum-augsburg.de [Klinikum Augsburg, Department of Radiology (Germany)

    2015-06-15

    PurposeEvaluation of patient radiation exposure during uterine artery embolization (UAE) and literature review to identify techniques minimizing required dose.MethodsA total of 224 of all included 286 (78 %) women underwent UAE according to a standard UAE-protocol (bilateral UAE from unilateral approach using a Rösch inferior mesenteric and a microcatheter, no aortography, no ovarian artery catheterization or embolization) and were analyzed for radiation exposure. Treatment was performed on three different generations of angiography systems: (I) new generation flat-panel detector (N = 108/151); (II) classical image amplifier and pulsed fluoroscopy (N = 79/98); (III) classical image amplifier and continuous fluoroscopy (N = 37/37). Fluoroscopy time (FT) and dose-area product (DAP) were documented. Whenever possible, the following dose-saving measures were applied: optimized source-object, source-image, and object-image distances, pulsed fluoroscopy, angiographic runs in posterior-anterior direction with 0.5 frames per second, no magnification, tight collimation, no additional aortography.ResultsIn a standard bilateral UAE, the use of the new generation flat-panel detector in group I led to a significantly lower DAP of 3,156 cGy × cm{sup 2} (544–45,980) compared with 4,000 cGy × cm{sup 2} (1,400–13,000) in group II (P = 0.033). Both doses were significantly lower than those of group III with 8,547 cGy × cm{sup 2} (3,324–35,729; P < 0.001). Other reasons for dose escalation were longer FT due to difficult anatomy or a large leiomyoma load, additional angiographic runs, supplementary ovarian artery embolization, and obesity.ConclusionsThe use of modern angiographic units with flat panel detectors and strict application of methods of radiation reduction lead to a significantly lower radiation exposure. Target DAP for UAE should be kept below 5,000 cGy × cm{sup 2}.

  13. Application of the ALARA principle to minimize the collective dose in NPP accident management within the containment

    International Nuclear Information System (INIS)

    Bogorad, V.; Slepchenko, O.; Kyrylenko, Y.

    2016-01-01

    The paper focuses on application of the ALARA principle to minimize the collective doses (both for NPP personnel and the public) related to admission of personnel to the containment for accident management activities and depending on operation of ventilation systems. Results from assessment of radiation consequences are applied to a small - break LOCA with failure of LPIS at VVER - 1000 reactors. The public doses are evaluated using up - to - date RODOS, MACCS and HotSpot software for assessment of radiation consequences. The personnel doses are evaluated with MicroShield and InterRAS codes. The time function and optimal value of the collective dose are defined. The developed approach can be applied for minimization of the collective dose for optimization of accident management strategies at NPPs

  14. Effect of low-dose valsartan on proteinuria in normotensive immunoglobulin A nephropathy with minimal proteinuria: a randomized trial.

    Science.gov (United States)

    Jo, Young-Il; Na, Ha-Young; Moon, Ju-Young; Han, Sang-Woong; Yang, Dong-Ho; Lee, Sang-Ho; Park, Hyeong-Cheon; Choi, Hoon-Young; Lim, So-Dug; Kie, Jeong-Hae; Lee, Yong-Kyu; Shin, Sug-Kyun

    2016-03-01

    Immunoglobulin A nephropathy (IgAN) is a generally progressive disease, even in patients with favorable prognostic features. In this study, we aimed to investigate the antiproteinuric effect and tolerability of low-dose valsartan (an angiotensin II receptor blocker) therapy in normotensive IgAN patients with minimal proteinuria of less than 0.5 to 1.0 g/day. Normotensive IgAN patients, who had persistent proteinuria with a spot urine protein-to-creatinine ratio of 0.3 to 1.0 mg/mg creatinine, were recruited from five hospitals and randomly assigned to either 40 mg of valsartan as the low-dose group or 80 mg of valsartan as the regular-dose group. Clinical and laboratory data were collected at baseline, and at 4, 8, 12, and 24 weeks after valsartan therapy. Forty-three patients (low-dose group, n = 23; regular-dose group, n = 20) were enrolled in the study. Proteinuria decreased significantly not only in the regular-dose group but also in the low-dose group. The change in urine protein-to-creatinine ratio at week 24 was -41.3% ± 26.1% (p valsartan can significantly reduce proteinuria without causing any intolerability in normotensive IgAN patients with minimal proteinuria.

  15. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  16. Low dose CT reconstruction via L1 norm dictionary learning using alternating minimization algorithm and balancing principle.

    Science.gov (United States)

    Wu, Junfeng; Dai, Fang; Hu, Gang; Mou, Xuanqin

    2018-04-18

    Excessive radiation exposure in computed tomography (CT) scans increases the chance of developing cancer and has become a major clinical concern. Recently, statistical iterative reconstruction (SIR) with l0-norm dictionary learning regularization has been developed to reconstruct CT images from the low dose and few-view dataset in order to reduce radiation dose. Nonetheless, the sparse regularization term adopted in this approach is l0-norm, which cannot guarantee the global convergence of the proposed algorithm. To address this problem, in this study we introduced the l1-norm dictionary learning penalty into SIR framework for low dose CT image reconstruction, and developed an alternating minimization algorithm to minimize the associated objective function, which transforms CT image reconstruction problem into a sparse coding subproblem and an image updating subproblem. During the image updating process, an efficient model function approach based on balancing principle is applied to choose the regularization parameters. The proposed alternating minimization algorithm was evaluated first using real projection data of a sheep lung CT perfusion and then using numerical simulation based on sheep lung CT image and chest image. Both visual assessment and quantitative comparison using terms of root mean square error (RMSE) and structural similarity (SSIM) index demonstrated that the new image reconstruction algorithm yielded similar performance with l0-norm dictionary learning penalty and outperformed the conventional filtered backprojection (FBP) and total variation (TV) minimization algorithms.

  17. Minimizing Patient-Specific Tracer Dose in Myocardial Perfusion Imaging Using CZT SPECT

    NARCIS (Netherlands)

    van Dijk, Joris David; Jager, Pieter L.; Ottervanger, Jan Paul; Slump, Cornelis H.; de Boer, Jaep; Oostdijk, Adrianus H.J.; van Dalen, Jorn A.

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT)

  18. Dose modeling in ultraviolet phototherapy

    International Nuclear Information System (INIS)

    Grimes, David Robert; Robbins, Chris; O'Hare, Neil John

    2010-01-01

    Purpose: Ultraviolet phototherapy is widely used in the treatment of numerous skin conditions. This treatment is well established and largely beneficial to patients on both physical and psychological levels; however, overexposure to ultraviolet radiation (UVR) can have detrimental effects, such as erythemal responses and ocular damage in addition to the potentially carcinogenic nature of UVR. For these reasons, it is essential to control and quantify the radiation dose incident upon the patient to ensure that it is both biologically effective and has the minimal possible impact on the surrounding unaffected tissue. Methods: To date, there has been little work on dose modeling, and the output of artificial UVR sources is an area where research has been recommended. This work characterizes these sources by formalizing an approach from first principles and experimentally examining this model. Results: An implementation of a line source model is found to give impressive accuracy and quantifies the output radiation well. Conclusions: This method could potentially serve as a basis for a full computational dose model for quantifying patient dose.

  19. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  20. Lessons Learned at Envirocare of Utah's Containerized Waste Facility (CWF): Dose Minimization Through ALARA Techniques and Tools

    International Nuclear Information System (INIS)

    Heckman, J.; Gardner, J.; Ledoux, M. R.

    2003-01-01

    Envirocare of Utah, Inc. (Envirocare) commenced operation of its Class A Containerized Waste Facility (CWF) on October 25, 2001. The opening of this facility began a new era for Envirocare, in that; their core business had always been low level, high volume, bulk radioactive waste. The CWF commenced operations to dispose of low level, low volume, high activity, containerized radioactive waste. Due to the potential for high dose rates on the waste disposal containers, the ALARA principle (As Low As Reasonably Achievable) plays an important role in the operation of the CWF and its mission to properly dispose of waste while minimizing doses to the workers, public, and the environment. This paper will enumerate some of the efforts made by the management and staff of the CWF that have contributed to significant dose reductions

  1. Low-dose CT of the paranasal sinuses. Minimizing X-ray exposure with spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, Wolfgang [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany); Radiological Institute, Erlangen (Germany); May, Matthias; Saake, Marc; Brand, Michael; Uder, Michael; Lell, Michael [Friedrich-Alexander-University Erlangen-Nuremberg, Radiological Institute, Erlangen (Germany)

    2016-11-15

    Shaping the energy spectrum of the X-ray beam has been shown to be beneficial in low-dose CT. This study's aim was to investigate dose and image quality of tin filtration at 100 kV for pre-operative planning in low-dose paranasal CT imaging in a large patient cohort. In a prospective trial, 129 patients were included. 64 patients were randomly assigned to the study protocol (100 kV with additional tin filtration, 150mAs, 192 x 0.6-mm slice collimation) and 65 patients to the standard low-dose protocol (100 kV, 50mAs, 128 x 0.6-mm slice collimation). To assess the image quality, subjective parameters were evaluated using a five-point scale. This scale was applied on overall image quality and contour delineation of critical anatomical structures. All scans were of diagnostic image quality. Bony structures were of good diagnostic image quality in both groups, soft tissues were of sufficient diagnostic image quality in the study group because of a high level of noise. Radiation exposure was very low in both groups, but significantly lower in the study group (CTDI{sub vol} 1.2 mGy vs. 4.4 mGy, p < 0.001). Spectral optimization (tin filtration at 100 kV) allows for visualization of the paranasal sinus with sufficient image quality at a very low radiation exposure. (orig.)

  2. Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm

    International Nuclear Information System (INIS)

    Min, Jong Hwan

    2011-02-01

    Dual-energy cone-beam CT is an important imaging modality in diagnostic applications, and may also find its use in other application such as therapeutic image guidance. Despite of its clinical values, relatively high radiation dose of dual-energy scan may pose a challenge to its wide use. In this work, we investigated a low-dose, pre-reconstruction type of dual-energy cone-beam CT (CBCT) using a total-variation minimization algorithm for image reconstruction. An empirical dual-energy calibration method was used to prepare material-specific projection data. Raw data at high and low tube voltages are converted into a set of basis functions which can be linearly combined to produce material-specific data using the coefficients obtained through the calibration process. From much fewer views than are conventionally used, material specific images are reconstructed by use of the total-variation minimization algorithm. An experimental study was performed to demonstrate the feasibility of the proposed method using a micro-CT system. We have reconstructed images of the phantoms from only 90 projections acquired at tube voltages of 40 kVp and 90 kVp each. Aluminum-only and acryl-only images were successfully decomposed. We evaluated the quality of the reconstructed images by use of contrast-to-noise ratio and detectability. A low-dose dual-energy CBCT can be realized via the proposed method by greatly reducing the number of projections

  3. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-12-07

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.

  4. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Directory of Open Access Journals (Sweden)

    Lo Pei-Yu

    2010-01-01

    Full Text Available Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers ( , 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/ and 200 mj/ , respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED which showed lower than visual assessment by 10 mj/ (Pearson correlation coefficient . A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  5. Initial dose of vancomycin based on body weight and creatinine clearance to minimize inadequate trough levels in Japanese adults.

    Science.gov (United States)

    Maki, N; Ohkuchi, A; Tashiro, Y; Kim, M R; Le, M; Sakamoto, T; Matsubara, S; Hakamata, Y

    2012-10-01

    Our aims were to elucidate the factors that affected vancomycin (VCM) serum trough levels and to find the optimal initial dose based on creatinine clearance (CrCl) and body weight (BW) to minimize inadequate trough levels in a retrospective observational study among Japanese adults. One hundred and six inpatients, in whom VCM trough levels were measured after completing the third dosing, were consecutively recruited into our study in a tertiary hospital. We considered the frequency of initial VCM total daily dose, CrCl, and BW were independent risk factors of VCM trough levels. In patients with CrCl ≥30 and level of ≥20 mcg/mL, regardless of BW. In patients with CrCl ≥50 mL/min, 2 g/day yielded low frequencies of a trough level of initial total daily dose may be 1 g/day in patients with CrCl ≥30 and <50 mL/min regardless of BW and 2 g/day in patients weighing <55 kg with CrCl ≥50 mL/min among Japanese adults.

  6. Evaluation of different doses of gamma radiation on physicochemical characteristics of peach Prunus persica (cv. Chimarrita) minimally processed

    International Nuclear Information System (INIS)

    Oliveira, Ana Claudia S.; Silva, Lucia C.A.S.; Perecin, Thalita Neme; Arthur, Valter; Harder, Marcia N.C.; Mansi, Debora N.; Canniatti-Brazaca, Solange G.

    2009-01-01

    The objective was to evaluate the effect of different doses of gamma radiation on the physico-chemical characteristics of peach Prunus persica (cv. Chimarrita) minimally processed, to increase the useful life of the fruit. The peaches were purchased at Ceasa of Campinas/SP and taken to the Laboratory of Radiobiology and Environment of CENA/USP (Piracicaba/SP), which were washed in tap water, peeled and cut into four pieces. The pieces of peach were dipped in sodium hypochlorite solution of 15 mL/L for 4 minutes and dry in a plastic support. Then it were placed in plastic containers (polypropylene). Subsequently, they were irradiated in a Cobalt-60 source, type Gammacell-220 (dose rate of 0,543 kGy/hour) with doses of: 0 (control), 1.0 and 2.0 kGy and stored at a temperature of 8 deg C. The experimental was developed entirely at random with 3 replicates for each treatment. For the statistic analysis was using the Tuckey test at 5% level of probability. Subsequently, analysis was carried out: color factors (l, a, b), pH, soluble solids (deg Brix), acidity and vitamin C. The tests were performed at 1, 3 and 6 days after irradiation. According to the results concluded that the analysis of color and acidity there was no significant difference between treatments, however, for the soluble solids (deg Brix), vitamin C and texture significant difference showing a decrease proportional to increasing doses of radiation and storage time. But the pH increased in relation to dose and during the analysis. (author)

  7. Changes in electrographic correlates of sleep-wakefulness cycle in cats irradiated with minimal lethal doses

    International Nuclear Information System (INIS)

    Kordzadze, R.N.; Nadarishvili, K.Sh.; Tsinitia, K.A.

    1983-01-01

    The paper deals with the dynamics of changes in bioelectrical activity (BEA) of the somatosensory cortex (SC) and dorsal hippocampus (DH) in the sleep-wakefulness (SW) cycle by means of a computer and automatized frequency analysis system in the course of chronic experiences with cats before and at various stages of development of radiation sickness (RS). The dose of single whole-body irradiation equaled 8 Gr (800+-20 rad). It has been shown that changes which occur in SC substantially differ in dependence on the stages of the SW cycle. More pronounced changes after irradiation are observed in low-frequency rhythms, particularly at the stage of deep slow wave sleep (DSWS) and less pronounced - in the paradoxical sleep (PS). Rhythmics shifts taking place in DH are mainly similar during wakefulness (W), superficial slow wave sleep (SSWS) and DSWS. In PS changes in rhythmics considerably differ as compared with We SSWS and DSWS. Revealed are also other specific shifts including a reliable enhancement of absolute value (AV) and specific ponderability (SP) of thera-rhythm of hippocampus during the RS acute period in animals survived the three week observation period. All this permits to conclude that BEA quantitative studies of various brain areas in the SW permit to reveal the trends in search of diagnostic and prognostic value of such investigations in case of different extreme states and to outline on the patogenetic basis correction methods for neutral disorders in case of RS

  8. Analysis of Ozone (O3 and Erythemal UV (EUV measured by TOMS in the equatorial African belt

    Directory of Open Access Journals (Sweden)

    Øyvind Frette

    2010-03-01

    Full Text Available We presented time series of total ozone column amounts (TOCAs and erythemal UV (EUV doses derived from measurements by TOMS (Total Ozone Mapping Spectrometer instruments on board the Nimbus-7 (N7 and the Earth Probe (EP satellites for three locations within the equatorial African belt for the period 1979 to 2000. The locations were Dar-es-Salaam (6.8° S, 39.26° E in Tanzania, Kampala (0.19° N, 32.34° E in Uganda, and Serrekunda (13.28° N, 16.34° W in Gambia. Equatorial Africa has high levels of UV radiation, and because ozone shields UV radiation from reaching the Earth’s surface, there is a need to monitor TOCAs and EUV doses. In this paper we investigated the trend of TOCAs and EUV doses, the effects of annual and solar cycles on TOCAs, as well as the link between lightning and ozone production in the equatorial African belt. We also compared clear-sky simulated EUV doses with the corresponding EUV doses derived from TOMS measurements. The TOCAs were found to vary in the ranges 243 DU − 289 DU, 231 DU − 286 DU, and 236 DU − 296 DU, with mean values of 266.9 DU, 260.9 DU, and 267.8 DU for Dar-es-Salaam, Kampala and Serrekunda, respectively. Daily TOCA time series indicated that Kampala had the lowest TOCA values, which we attributed to the altitude effect. There were two annual ozone peaks in Dar-es-Salaam and Kampala, and one annual ozone peak in Serrekunda. The yearly TOCA averages showed an oscillation within a five-year period. We also found that the EUV doses were stable at all three locations for the period 1979−2000, and that Kampala and Dar-es-Salaam were mostly cloudy throughout the year, whereas Serrekunda was mostly free from clouds. It was also found that clouds were among the major factors determining the level of EUV reaching the Earth´s surface. Finally, we noted that during rainy seasons, horizontal advection effects augmented by lightning activity may be responsible for enhanced ozone production in the tropics.

  9. Recommendations to designers aimed at minimizing radiation dose incurred in operation, maintenance, inspection and repair of light-water reactors

    International Nuclear Information System (INIS)

    1978-01-01

    In the framework of the exchange of experience between nuclear power plant operators organized by the services of the Commission of the European Communities an ad-hoc working party elaborated recommendations particularly directed to those concerned with design of light water reactor plants. The necessary design measures which should be followed to minimize radiation dose incurred in operation, maintenance, inspection and repair of such reactors are listed. The recommendations are based on recent views expressed by operating utilities within the Community. It is intended to revise these recommendations at suitable intervals in order to make use of the most recent experience and to keep the report up to date with the actual state of art in nuclear technology

  10. Temporal variation of erythemally effective UVB/UVA ratio at Chilton, UK

    International Nuclear Information System (INIS)

    Hooke, R. J.; Pearson, A. J.; O'Hagan, J. B.

    2012-01-01

    An analysis of the temporal variation in the erythemally weighted UVB/UVA irradiance ratio using spectral data collected from a monitoring site in Chilton, UK (51 deg. N) for the 5-y period from 2004 to 2008 is presented. The variation in the diurnal ratio was found to be bell-shaped, with minima on average 1 h after sunrise and before sunset. The minima were found to be indicative of the point at which UVB becomes undetectable by the spectro-radiometer and therefore the outer boundary of useful data. A potential flaw entailed in the erythemal weighting of low-level spectral UV data is described. The peak daily ratio value was found to have a bell-shaped distribution over the course of a year with a maximum in July rather than at the summer solstice-a result explained by the ozone cycle. The peak daily ratio was found to vary by a factor of 4 over the course of the year; this range of variation was also found to occur over a single day in the summer. (authors)

  11. Personal exposure distribution of solar erythemal ultraviolet radiation in tree shade over summer

    International Nuclear Information System (INIS)

    Parisi, A.V.; Wong, J.C.F.

    2000-01-01

    The personal radiant exposure distribution of solar erythemal UV in tree shade for an upright posture was measured, with measurements over the whole summer for a total of 17 trees. For each tree, the personal radiant exposure distribution was measured for both the morning and afternoon periods. The exposure ratios averaged over all the trees and over the morning and afternoon periods ranged from 0.16 to 0.49 for the different anatomical sites. A numerical model was employed to estimate the UV radiant exposure to humans in tree shade over the entire summer. The body sites with the higher exposure ratios in the tree shade were the vertex of the head, shoulders and forearms with radiant exposures over the summer of 1300 MED to the vertex of the head and 1100 MED to the shoulders and forearms. These radiant exposures in the shade are substantially higher than the ambient erythemal UV measured in full sun on a horizontal plane over a full summer at a more temperate northern hemisphere latitude. The average radiant exposures per day to each anatomical site for a complete day in the tree shade ranged from 4.6 to 14.6 MED. This research has provided new data that is essential to quantify human UV exposure during outdoor activities. (author)

  12. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Science.gov (United States)

    Huang, Min-Wei; Lo, Pei-Yu; Cheng, Kuo-Sheng

    2010-12-01

    Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers ([InlineEquation not available: see fulltext.]), 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/[InlineEquation not available: see fulltext.] and 200 mj/[InlineEquation not available: see fulltext.], respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter [InlineEquation not available: see fulltext.] value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED) which showed lower than visual assessment by 10 mj/[InlineEquation not available: see fulltext.] (Pearson correlation coefficient [InlineEquation not available: see fulltext.]). A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  13. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Directory of Open Access Journals (Sweden)

    Kuo-Sheng Cheng

    2010-01-01

    Full Text Available Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers (n=20, 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/cm2 and 200 mj/cm2, respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter a∗ value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED which showed lower than visual assessment by 10 mj/cm2 (Pearson correlation coefficient ℑ=0.758. A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  14. Development of a Chlorine Dosing Strategy for Fresh Produce Washing Process to Maintain Microbial Food Safety and Minimize Residual Chlorine.

    Science.gov (United States)

    Chen, Xi; Hung, Yen-Con

    2018-05-22

    The residual free chlorine level in fresh produce wash solution is closely correlated to the chemical and microbial safety of produce. Excess amount of free chlorine can quickly react with organic matters to form hazardous disinfection by-products (DBPs) above EPA-permitted levels, whereas deficiency of residual chlorine in produce wash solution may result in incompletely removing pathogens on produce. The purpose of this study was to develop a chlorine dosing strategy to optimize the chlorine dosage during produce washing process without impacting the microbial safety of fresh produce. Prediction equations were developed to estimate free chlorine needed to reach targeted residual chlorine at various sanitizer pH and organic loads, and then validated using fresh-cut iceberg lettuce and whole strawberries in an automated produce washer. Validation results showed that equations successfully predicted the initial chlorine concentration needed to achieve residual chlorine at 10, 30, 60, and 90 mg/L for both lettuce and strawberry washing processes, with the root mean squared error at 4.45 mg/L. The Escherichia coli O157:H7 reductions only slightly increased on iceberg lettuce and strawberries with residual chlorine increasing from 10 to 90 mg/L, indicating that lowering residual chlorine to 10 mg/L would not compromise the antimicrobial efficacy of chlorine-based sanitizer. Based on the prediction equations and E. coli O157:H7 reduction results, a chlorine dosing strategy was developed to help the produce industry to maintain microbial inactivation efficacy without adding excess amount of free chlorine. The chlorine dosing strategy can be used for fresh produce washing process to enhance the microbial food safety and minimize the DBPs formation potential. © 2018 Institute of Food Technologists®.

  15. Calibration of erythemally weighted broadband instruments: A comparison between PMOD/WRC and MSL

    International Nuclear Information System (INIS)

    Swift, Neil; Nield, Kathryn; Hamlin, John; Hülsen, Gregor; Gröbner, Julian

    2013-01-01

    A Yankee Environmental Systems (YES) UVB-1 ultraviolet pyranometer, designed to measure erythemally weighted total solar irradiance, was calibrated by the Measurement Standards Laboratory (MSL) in Lower Hutt, New Zealand during August 2010. The calibration was then repeated during July and August 2011 by the Physikalisch-Meteorologisches Obervatorium Davos, World Radiation Center (PMOD/WRC) located in Davos, Switzerland. Calibration results show that measurements of the relative spectral and angular response functions at the two institutes are in excellent agreement, thus providing a good degree of confidence in these measurement facilities. However, measurements to convert the relative spectral response into an absolute calibration disagree significantly depending on whether an FEL lamp or solar spectra are used to perform this scaling. This is the first serious comparison of these scaling methods to formally explore the potential systematic errors which could explain the discrepancy.

  16. Influence of the relative optical air mass on ultraviolet erythemal irradiance

    Science.gov (United States)

    Antón, M.; Serrano, A.; Cancillo, M. L.; García, J. A.

    2009-12-01

    The main objective of this article is to analyze the relationship between the transmissivity for ultraviolet erythemal irradiance (UVER) and the relative optical air mass at Badajoz (Southwestern Spain). Thus, a power expression between both variables is developed, which analyses in detail how atmospheric transmission is influenced by the total ozone column (TOC) and the atmospheric clearness. The period of analysis extends from 2001 to 2005. The experimental results indicate that clearness conditions play an important role in the relationship between UVER transmissivity and the relative optical air mass, while the effect of TOC is much smaller for this data set. In addition, the results show that UVER transmissivity is more sensitive to changes in atmospheric clearness than to TOC variability. Changes in TOC values higher than 15% cause UVER trasnmissivity to vary between 14% and 22%, while changes between cloud-free and overcast conditions produce variations in UVER transmissivity between 68% and 74% depending on the relative optical air mass.

  17. Calibration of erythemally weighted broadband instruments: A comparison between PMOD/WRC and MSL

    Energy Technology Data Exchange (ETDEWEB)

    Swift, Neil; Nield, Kathryn; Hamlin, John [Measurement Standards Laboratory of New Zealand, Industrial Research Ltd, Lower Hutt (New Zealand); Huelsen, Gregor; Groebner, Julian [Physikalisch-Meteorologisches Observatorium Davos, World Radiation Centre, Davos Dorf (Switzerland)

    2013-05-10

    A Yankee Environmental Systems (YES) UVB-1 ultraviolet pyranometer, designed to measure erythemally weighted total solar irradiance, was calibrated by the Measurement Standards Laboratory (MSL) in Lower Hutt, New Zealand during August 2010. The calibration was then repeated during July and August 2011 by the Physikalisch-Meteorologisches Obervatorium Davos, World Radiation Center (PMOD/WRC) located in Davos, Switzerland. Calibration results show that measurements of the relative spectral and angular response functions at the two institutes are in excellent agreement, thus providing a good degree of confidence in these measurement facilities. However, measurements to convert the relative spectral response into an absolute calibration disagree significantly depending on whether an FEL lamp or solar spectra are used to perform this scaling. This is the first serious comparison of these scaling methods to formally explore the potential systematic errors which could explain the discrepancy.

  18. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.

  19. SU-G-JeP2-09: Minimal Skin Dose Increase in Longitudinal Rotating Biplanar Linac-MR Systems: Examination of Radiation Energy and Flattening Filter Design

    Energy Technology Data Exchange (ETDEWEB)

    Fallone, B; Keyvanloo, A; Burke, B; St Aubin, J; Baillie, D; Wachowicz, K; Warkentin, B; Steciw, S [Cross Cancer Institute, Edmonton, AB (Canada)

    2016-06-15

    Purpose: To quantify increase in entrance skin-dose due to magnetic fields of the Alberta longitudinal linac-MR by examining the effect of radiation energy and flattening filter, using Monte Carlo calculations and accurate 3-D models of the magnetic field. Methods: The 3-D magnetic fields generated by the bi-planar Linac-MR are calculated with FEM using Opera-3D. BEAMnrc simulates the particle phase-space in the presence of the rapidly decaying fringe field of 0.5T MRI assembled with a Varian 600C linac with an isocentre distance of 130 cm for 6 MV and 10 MV beams. Skin doses are calculated at an average depth of 70 µm using DOSXYZnrc with varying SSDs and field sizes. Furthermore, flattening filters are reshaped to compensate for the significant drop in dose rate due to increased SAD of 130 cm and skin-doses are evaluated. Results: The confinement effect of the MRI fringe field on the contaminant electrons is minimal. For SSDs of 100 – 120 cm the increase in skin dose is ∼6% – 19% and ∼1% – 9% for the 6 and 10 MV beams, respectively. For 6MV, skin dose increases from ∼10.5% to 1.5%. for field-size increases of 5×5 cm2 to 20×20 cm2. For 10 MV, skin dose increases by ∼6% for a 5×5 cm2 field, and decreases by ∼1.5% for a 20×20 cm2 field. The reshaped flattening filter increases the dose rate from 355 MU/min to 529 MU/min (6 MV) or 604 MU/min (10 MV), while the skin-dose increases by only an additional ∼2.6% (all percent increases in skin dose are relative to Dmax). Conclusion: There is minimal increase in the entrance skin dose and minimal/no decrease in the dose rate of the Alberta longitudinal linac-MR system. There is even lower skin-dose increase at 10 MV. Funding: Alberta Innovates - Health Solutions (AIHS) Conflict of Interest: Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

  20. TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

    International Nuclear Information System (INIS)

    Li, H; Zhang, X; Zhu, X; Li, Y

    2014-01-01

    Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy

  1. Gerbstoffe aus Potentilla officinalis wirken entzündungshemmend im UV-Erythem-Test und bei Anwendung auf atopischer Haut.

    Science.gov (United States)

    Hoffmann, Julia; Wölfle, Ute; Schempp, Christoph M; Casetti, Federica

    2016-09-01

    Das Rhizom von Potentilla officinalis (PO) ist reich an Gerbstoffen und wird traditionell zur äußerlichen Behandlung von Entzündungen der Haut und der Schleimhäute verwendet. Ziel der vorliegenden Arbeit war die Bestätigung der antiinflammatorischen Eigenschaften von PO mittels eines UV-Erythem-Tests und einer klinischen Anwendungsstudie bei atopischer Haut. Die antiinflammatorische Wirkung eines PO-Extrakts (standardisiert auf 2 % Trockensubstanz) wurde in einer prospektiven, randomisierten, placebokontrollierten Doppelblindstudie mit 40 gesunden Erwachsenen im UV-Erythem-Test im Vergleich zu 1 % Hydrocortisonacetat untersucht. Im Rahmen einer prospektiven nicht kontrollierten Studie wurde die Wirkung und Verträglichkeit der 2 % PO-Creme an zwölf Erwachsenen und zwölf Kindern mit atopischer Haut nach Anwendung über zwei Wochen in einem definierten Testareal anhand eines Teil-SCORAD untersucht. Zusätzlich wurde die Beeinflussung der Hautrötung im Testareal photometrisch gemessen. Im UV-Erythem-Test zeigte die PO-Creme eine signifikante Reduktion des Erythemindex im Vergleich zum Vehikel. Die antiinflammatorische Wirkung des Verums entsprach der der 1 % Hydrocortisonacetat-Creme. Die klinische Studie bei Atopikern zeigte eine signifikante Abnahme des Teil-SCORAD und des Erythems im Testareal. Es wurden keine Unverträglichkeitsreaktionen beobachtet. PO als 2%ige Zubereitung besitzt entzündungshemmende Eigenschaften und ist wirksam und gut verträglich auf atopischer Haut. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  2. Trends in total column ozone over Australia and New Zealand and its influence on clear-sky surface erythemal irradiance

    International Nuclear Information System (INIS)

    Bodeker, G. E.

    1995-01-01

    Australia and New Zealand are two of the countries closest to the Antarctic ozone depletion and may therefore be 'at risk' as a result of the associated increases in surface ultraviolet (UV) radiation. To investigate the possible impact of mid-latitude ozone decreases on surface erythemal irradiances, monthly mean total ozone has been calculated from daily total ozone mapping spectrometer data for 5 Australian cities (Canberra, Hobart, Melbourne, Perth and Sydney) and 3 New Zealand cities (Auckland, Christchurch and Wellington) from 1979 to 1992. These values have then been used as inputs to a single layer model to calculate noon clear-sky global UV irradiances and associated erythemal irradiances. In addition, the monthly mean ozone data have been modelled statistically for each location to reveal a long-term linear trend, an annual variation, a Quasi-Biennial Oscillation (QBO), a solar cycle component and a semi-annual (6 month) signal. Coefficients from these statistical models have been used to estimate monthly mean ozone and noon clear-sky erythemal irradiances to the year 2000 for each city. It is assumed that the rate of increase of stratospheric chlorine over the remainder of the century will remain constant. Given that there is some evidence that the rate of increase is decreasing, the results present here should be regarded as an upper limit. 33 refs., 7 tabs., 4 figs

  3. Reconstruction and analysis of erythemal UV radiation time series from Hradec Králové (Czech Republic) over the past 50 years

    Science.gov (United States)

    Čížková, Klára; Láska, Kamil; Metelka, Ladislav; Staněk, Martin

    2018-02-01

    This paper evaluates the variability of erythemal ultraviolet (EUV) radiation from Hradec Králové (Czech Republic) in the period 1964-2013. The EUV radiation time series was reconstructed using a radiative transfer model and additional empirical relationships, with the final root mean square error of 9.9 %. The reconstructed time series documented the increase in EUV radiation doses in the 1980s and the 1990s (up to 15 % per decade), which was linked to the steep decline in total ozone (10 % per decade). The changes in cloud cover were the major factor affecting the EUV radiation doses especially in the 1960s, 1970s, and at the beginning of the new millennium. The mean annual EUV radiation doses in the decade 2004-2013 declined by 5 %. The factors affecting the EUV radiation doses differed also according to the chosen integration period (daily, monthly, and annually): solar zenith angle was the most important for daily doses, cloud cover, and surface UV albedo for their monthly means, and the annual means of EUV radiation doses were most influenced by total ozone column. The number of days with very high EUV radiation doses increased by 22 % per decade, the increase was statistically significant in all seasons except autumn. The occurrence of the days with very high EUV doses was influenced mostly by low total ozone column (82 % of days), clear-sky or partly cloudy conditions (74 % of days) and by increased surface albedo (19 % of days). The principal component analysis documented that the occurrence of days with very high EUV radiation doses was much affected by the positive phase of North Atlantic Oscillation with an Azores High promontory reaching over central Europe. In the stratosphere, a strong Arctic circumpolar vortex and the meridional inflow of ozone-poor air from the southwest were favorable for the occurrence of days with very high EUV radiation doses. This is the first analysis of the relationship between the high EUV radiation doses and macroscale

  4. Reconstruction of daily erythemal UV radiation values for the last century - The benefit of modelled ozone

    Science.gov (United States)

    Junk, J.; Feister, U.; Rozanov, E.; Krzyścin, J. W.

    2013-05-01

    Solar erythemal UV radiation (UVER) is highly relevant for numerous biological processes that affect plants, animals, and human health. Nevertheless, long-term UVER records are scarce. As significant declines in the column ozone concentration were observed in the past and a recovery of the stratospheric ozone layer is anticipated by the middle of the 21st century, there is a strong interest in the temporal variation of UVER time series. Therefore, we combined groundbased measurements of different meteorological variables with modeled ozone data sets to reconstruct time series of daily totals of UVER at the Meteorological Observatory Potsdam, Germany. Artificial neural networks were trained with measured UVER, sunshine duration, the day of year, measured and modeled total column ozone, as well as the minimum solar zenith angle. This allows for the reconstruction of daily totals of UVER for the period from 1901 to 1999. Additionally, analyses of the long-term variations from 1901 until 1999 of the reconstructed, new UVER data set are presented. The time series of monthly and annual totals of UVER provide a long-term meteorological basis for epidemiological investigations in human health and occupational medicine for the region of Potsdam and Berlin. A strong benefit of our ANN-approach is the fact that it can be easily adapted to different geographical locations, as successfully tested in the framework of the COSTAction 726.

  5. Use of satellite erythemal UV products in analysing the global UV changes

    Directory of Open Access Journals (Sweden)

    I. Ialongo

    2011-09-01

    Full Text Available Long term changes in solar UV radiation affect global bio-geochemistry and climate. The satellite-based dataset of TOMS (Total Ozone Monitoring System and OMI (Ozone Monitoring Instrument of erythemal UV product was applied for the first time to estimate the long-term ultraviolet (UV changes at the global scale. The analysis of the uncertainty related to the different input information is presented. OMI and GOME-2 (Global Ozone Monitoring Experiment-2 products were compared in order to analyse the differences in the global UV distribution and their effect on the linear trend estimation.

    The results showed that the differences in the inputs (mainly surface albedo and aerosol information used in the retrieval, affect significantly the UV change calculation, pointing out the importance of using a consistent dataset when calculating long term UV changes. The areas where these differences played a major role were identified using global maps of monthly UV changes. Despite the uncertainties, significant positive UV changes (ranging from 0 to about 5 %/decade were observed, with higher values in the Southern Hemisphere at mid-latitudes during spring-summer, where the largest ozone decrease was observed.

  6. Influence of low ozone episodes on erythemal UV-B radiation in Austria

    Science.gov (United States)

    Schwarz, Matthias; Baumgartner, Dietmar J.; Pietsch, Helga; Blumthaler, Mario; Weihs, Philipp; Rieder, Harald E.

    2017-06-01

    This study investigates the influence of low ozone episodes on UV-B radiation in Austria during the period 1999 to 2015. To this aim observations of total column ozone (TCO) in the Greater Alpine Region (Arosa, Switzerland; Hohenpeissenberg, Germany; Hradec Kralove, Czech Republic; Sonnblick, Austria), and erythemal UV-B radiation, available from 12 sites of the Austrian UV-B monitoring network, are analyzed. As previous definitions for low ozone episodes are not particularly suited to investigate effects on UV radiation, a novel threshold approach—considering anomalies—is developed to provide a joint framework for the analysis of extremes. TCO and UV extremes are negatively correlated, although modulating effects of sunshine duration impact the robustness of the statistical relationship. Therefore, information on relative sunshine duration (SDrel), available at (or nearby) UV-B monitoring sites, is included as explanatory variable in the analysis. The joint analysis of anomalies of both UV index (UVI) and total ozone (∆UVI, ∆TCO) and SDrel across sites shows that more than 65% of observations with strongly negative ozone anomalies (∆TCO 1), we find (across all sites) that about 90% correspond to negative ∆TCO. The remaining 10% of days occurred during fair weather conditions (SDrel ≥ 80%) explaining the appearance of ∆UVI > 1 despite positive TCO anomalies. Further, we introduce an anomaly amplification factor (AAF), which quantifies the expected change of the ∆UVI for a given change in ∆TCO.

  7. Minimizing dose variation from the interplay effect in stereotactic radiation therapy using volumetric modulated arc therapy for lung cancer.

    Science.gov (United States)

    Kubo, Kazuki; Monzen, Hajime; Tamura, Mikoto; Hirata, Makoto; Ishii, Kentaro; Okada, Wataru; Nakahara, Ryuta; Kishimoto, Shun; Kawamorita, Ryu; Nishimura, Yasumasa

    2018-03-01

    It is important to improve the magnitude of dose variation that is caused by the interplay effect. The aim of this study was to investigate the impact of the number of breaths (NBs) to the dose variation for VMAT-SBRT to lung cancer. Data on respiratory motion and multileaf collimator (MLC) sequence were collected from the cases of 30 patients who underwent radiotherapy with VMAT-SBRT for lung cancer. The NBs in the total irradiation time with VMAT and the maximum craniocaudal amplitude of the target were calculated. The MLC sequence complexity was evaluated using the modulation complexity score for VMAT (MCSv). Static and dynamic measurements were performed using a cylindrical respiratory motion phantom and a micro ionization chamber. The 1 standard deviation which were obtained from 10 dynamic measurements for each patient were defined as dose variation caused by the interplay effect. The dose distributions were also verified with radiochromic film to detect undesired hot and cold dose spot. Dose measurements were also performed with different NBs in the same plan for 16 patients in 30 patients. The correlations between dose variations and parameters assessed for each treatment plan including NBs, MCSv, the MCSv/amplitude quotient (TMMCSv), and the MCSv/amplitude quotient × NBs product (IVS) were evaluated. Dose variation was decreased with increasing NBs, and NBs of >40 times maintained the dose variation within 3% in 15 cases. The correlation between dose variation and IVS which were considered NBs was shown stronger (R 2  = 0.43, P 40 times during irradiation of two partial arcs VMAT (i.e., NBs = 16 breaths per minute) may be suitable for VMAT-SBRT for lung cancer. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam.

    Science.gov (United States)

    Whitaker, Thomas J; Beltran, Chris; Tryggestad, Erik; Bues, Martin; Kruse, Jon J; Remmes, Nicholas B; Tasson, Alexandria; Herman, Michael G

    2014-08-01

    Delayed charge is a small amount of charge that is delivered to the patient after the planned irradiation is halted, which may degrade the quality of the treatment by delivering unwarranted dose to the patient. This study compares two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam. The delivery of several treatment plans was simulated by applying a normally distributed value of delayed charge, with a mean of 0.001(SD 0.00025) MU, to each spot. Two correction methods were used to account for the delayed charge. Method one (CM1), which is in active clinical use, accounts for the delayed charge by adjusting the MU of the current spot based on the cumulative MU. Method two (CM2) in addition reduces the planned MU by a predicted value. Every fraction of a treatment was simulated using each method and then recomputed in the treatment planning system. The dose difference between the original plan and the sum of the simulated fractions was evaluated. Both methods were tested in a water phantom with a single beam and simple target geometry. Two separate phantom tests were performed. In one test the dose per fraction was varied from 0.5 to 2 Gy using 25 fractions per plan. In the other test the number fractions were varied from 1 to 25, using 2 Gy per fraction. Three patient plans were used to determine the effect of delayed charge on the delivered dose under realistic clinical conditions. The order of spot delivery using CM1 was investigated by randomly selecting the starting spot for each layer, and by alternating per layer the starting spot from first to last. Only discrete spot scanning was considered in this study. Using the phantom setup and varying the dose per fraction, the maximum dose difference for each plan of 25 fractions was 0.37-0.39 Gy and 0.03-0.05 Gy for CM1 and CM2, respectively. While varying the total number of fractions, the maximum dose difference increased at a rate

  9. Comparison of two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam

    International Nuclear Information System (INIS)

    Whitaker, Thomas J.; Beltran, Chris; Tryggestad, Erik; Kruse, Jon J.; Remmes, Nicholas B.; Tasson, Alexandria; Herman, Michael G.; Bues, Martin

    2014-01-01

    Purpose: Delayed charge is a small amount of charge that is delivered to the patient after the planned irradiation is halted, which may degrade the quality of the treatment by delivering unwarranted dose to the patient. This study compares two methods for minimizing the effect of delayed charge on the dose delivered with a synchrotron based discrete spot scanning proton beam. Methods: The delivery of several treatment plans was simulated by applying a normally distributed value of delayed charge, with a mean of 0.001(SD 0.00025) MU, to each spot. Two correction methods were used to account for the delayed charge. Method one (CM1), which is in active clinical use, accounts for the delayed charge by adjusting the MU of the current spot based on the cumulative MU. Method two (CM2) in addition reduces the planned MU by a predicted value. Every fraction of a treatment was simulated using each method and then recomputed in the treatment planning system. The dose difference between the original plan and the sum of the simulated fractions was evaluated. Both methods were tested in a water phantom with a single beam and simple target geometry. Two separate phantom tests were performed. In one test the dose per fraction was varied from 0.5 to 2 Gy using 25 fractions per plan. In the other test the number fractions were varied from 1 to 25, using 2 Gy per fraction. Three patient plans were used to determine the effect of delayed charge on the delivered dose under realistic clinical conditions. The order of spot delivery using CM1 was investigated by randomly selecting the starting spot for each layer, and by alternating per layer the starting spot from first to last. Only discrete spot scanning was considered in this study. Results: Using the phantom setup and varying the dose per fraction, the maximum dose difference for each plan of 25 fractions was 0.37–0.39 Gy and 0.03–0.05 Gy for CM1 and CM2, respectively. While varying the total number of fractions, the maximum dose

  10. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  11. 8-MOP PUVA for psoriasis: a comparison of a minimal phototoxic dose-based regimen with a skin-type approach

    Energy Technology Data Exchange (ETDEWEB)

    Collins, P.; Wainwright, N.J.; Amorim, I.; Lakshmipathi, T.; Ferguson, J. [Ninewells Hospital and Medical School, Dundee (United Kingdom)

    1996-08-01

    Two ultraviolet A (UVA) regimens for oral 8-methoxypsoralen (8-MOP) photochemotherapy (PUVA) for moderate/severe chronic plaque psoriasis using a half-body study technique were compared. Each patient received both regimens. A higher-dose regimen based on minimal phototoxic dose (MPD) with percentage incremental increases was given to one-half of the body. The other half received a lower dose regimen based on skin type with fixed incremental UVA increases. Patients were treated twice weekly. Symmetrical plaques were scored to determine the rate of resolution with each regimen. In addition, the number of treatments, cumulative UVA dose and number of days in treatment to achieve overall clearance were recorded. Patients were reviewed monthly for one year to record remission data. Thirty-three patients completed the study. Both regimens were effective and well tolerated. With the MPD-based approach, number of exposures was significantly less for patients with skin types I and II but not III. Although the cumulative UVA dose was higher with the MPD regimen for all skin types studied, the reduced number of exposures required for clearance for skin types I and II but not III, combined with the security of individualized MPD testing, has practical attractions. MPD testing also identified five patients who required an increased psoralen dose and six patients who required a reduction of the initial UVA dose with the skin type regimen. Forty-two percent were still clear 1 year after treatment and there was no significant difference in the number of days in remission between the regimens for those whose psoriasis had recurred. The reduction in the number of exposures required for clearance with the MPD-based regimen may be safer and more cost effective in the long term. (author).

  12. Effect of follow-up period on minimal-significant dose in the atomic-bomb survivor studies

    Energy Technology Data Exchange (ETDEWEB)

    Cologne, John; Grant, Eric J.; Cullings, Harry M.; Ozasa, Kotaro [Radiation Effects Research Foundation, Hiroshima (Japan); Preston, Dale L. [Hirosoft International, Eureka, CA (United States)

    2018-03-15

    It was recently suggested that earlier reports on solid-cancer mortality and incidence in the Life Span Study of atomic-bomb survivors contain still-useful information about low-dose risk that should not be ignored, because longer follow-up may lead to attenuated estimates of low-dose risk due to longer time since exposure. Here it is demonstrated, through the use of all follow-up data and risk models stratified on period of follow-up (as opposed to sub-setting the data by follow-up period), that the appearance of risk attenuation over time may be the result of less-precise risk estimation - in particular, imprecise estimation of effect-modification parameters - in the earlier periods. Longer follow-up, in addition to allowing more-precise estimation of risk due to larger numbers of radiation-related cases, provides more-precise adjustment for background mortality or incidence and more-accurate assessment of risk modification by age at exposure and attained age. It is concluded that the latest follow-up data are most appropriate for inferring low-dose risk. Furthermore, if researchers are interested in effects of time since exposure, the most-recent follow-up data should be considered rather than the results of earlier reports. (orig.)

  13. Effect of low-dose γ-irradiation on the shelf life and quality characteristics of minimally processed potato cubes under modified atmosphere packaging

    International Nuclear Information System (INIS)

    Baskaran, Revathy; Usha Devi, A.; Nayak, Chetan A.; Kudachikar, V.B.; Keshava Prakash, M.N.; Prakash, Maya; Ramana, K.V.R.; Rastogi, N.K.

    2007-01-01

    The processing conditions involving γ-irradiation for minimally processed potato cubes were optimized by response surface methodology. The effect of γ-irradiation dose (0-1.5 kGy), citric acid concentration (0-1.0%), KMS concentration (0-1.0%) and their complex interaction on L, a, b value, hardness and total sugar content were studied using a central composite rotatable design of experiments. The results showed that at the optimum conditions (γ-irradiation dose 1.0 kGy; citric acid concentration 0.33% and KMS concentration 0.55%) the L-value was ≥48.50%, a-value ≤0.95, b-value ≤7.5, hardness ≥100 N, sucrose concentration ≤0.19% and sensory score ≥6.0 at the end of the storage period of 4 weeks

  14. Minimal percentage of dose received by 90% of the urethra (%UD90) is the most significant predictor of PSA bounce in patients who underwent low-dose-rate brachytherapy (LDR-brachytherapy) for prostate cancer.

    Science.gov (United States)

    Tanaka, Nobumichi; Asakawa, Isao; Fujimoto, Kiyohide; Anai, Satoshi; Hirayama, Akihide; Hasegawa, Masatoshi; Konishi, Noboru; Hirao, Yoshihiko

    2012-09-14

    To clarify the significant clinicopathological and postdosimetric parameters to predict PSA bounce in patients who underwent low-dose-rate brachytherapy (LDR-brachytherapy) for prostate cancer. We studied 200 consecutive patients who received LDR-brachytherapy between July 2004 and November 2008. Of them, 137 patients did not receive neoadjuvant or adjuvant androgen deprivation therapy. One hundred and forty-two patients were treated with LDR-brachytherapy alone, and 58 were treated with LDR-brachytherapy in combination with external beam radiation therapy. The cut-off value of PSA bounce was 0.1 ng/mL. The incidence, time, height, and duration of PSA bounce were investigated. Clinicopathological and postdosimetric parameters were evaluated to elucidate independent factors to predict PSA bounce in hormone-naïve patients who underwent LDR-brachytherapy alone. Fifty patients (25%) showed PSA bounce and 10 patients (5%) showed PSA failure. The median time, height, and duration of PSA bounce were 17 months, 0.29 ng/mL, and 7.0 months, respectively. In 103 hormone-naïve patients treated with LDR-brachytherapy alone, and univariate Cox proportional regression hazard model indicated that age and minimal percentage of the dose received by 30% and 90% of the urethra were independent predictors of PSA bounce. With a multivariate Cox proportional regression hazard model, minimal percentage of the dose received by 90% of the urethra was the most significant parameter of PSA bounce. Minimal percentage of the dose received by 90% of the urethra was the most significant predictor of PSA bounce in hormone-naïve patients treated with LDR-brachytherapy alone.

  15. Disparity in Cutaneous Pigmentary Response to LED vs Halogen Incandescent Visible Light: Results from a Single Center, Investigational Clinical Trial Determining a Minimal Pigmentary Visible Light Dose.

    Science.gov (United States)

    Soleymani, Teo; Cohen, David E; Folan, Lorcan M; Okereke, Uchenna R; Elbuluk, Nada; Soter, Nicholas A

    2017-11-01

    Background: While most of the attention regarding skin pigmentation has focused on the effects of ultraviolet radiation, the cutaneous effects of visible light (400 to 700nm) are rarely reported. The purpose of this study was to investigate the cutaneous pigmentary response to pure visible light irradiation, examine the difference in response to different sources of visible light irradiation, and determine a minimal pigmentary dose of visible light irradiation in melanocompetent subjects with Fitzpatrick skin type III - VI. The study was designed as a single arm, non-blinded, split-side dual intervention study in which subjects underwent visible light irradiation using LED and halogen incandescent light sources delivered at a fluence of 0.14 Watts/cm2 with incremental dose progression from 20 J/cm2 to 320 J/cm2. Pigmentation was assessed by clinical examination, cross-polarized digital photography, and analytic colorimetry. Immediate, dose-responsive pigment darkening was seen with LED light exposure in 80% of subjects, beginning at 60 Joules. No pigmentary changes were seen with halogen incandescent light exposure at any dose in any subject. This study is the first to report a distinct difference in cutaneous pigmentary response to different sources of visible light, and the first to demonstrate cutaneous pigment darkening from visible LED light exposure. Our findings raise the concern that our increasing daily artificial light surroundings may have clandestine effects on skin biology. J Drugs Dermatol. 2017;16(11):1105-1110..

  16. Decision of special monitoring time to minimize the difference of the committed effective dose evaluated from the different AMAD

    International Nuclear Information System (INIS)

    Lee, J. I.; Lee, T. Y.; Jang, S. Y.; Lee, J. K.

    2003-01-01

    The Committed Effective Doses (CEDs) per measured unit of activity in the bioassay compartments at any time (t) after an acute intake by the inhalation of a radionuclide with a different particle size (AMAD) were calculated and compared. As a result, the relative difference between the CEDs evaluated from the different AMAD is affected by the radionuclide, bioassay compartment, and the time (t) after intake. Therefore a special monitoring time to exclude or reduce the effect of AMAD was decided and presented in the evaluation for the CEDs following an acute intake by the inhalation of a radionuclide. If special monitoring is performed during this presented special time after intake, the relative difference of the evaluated CEDs resulted from AMAD can be excluded or reduced

  17. TOMS/Earth Probe UV-B Erythemal Local Noon Irradiance Monthly L3 Global 1x1.25 deg Lat/Lon Grid V008

    Data.gov (United States)

    National Aeronautics and Space Administration — This data product contains TOMS/Earth Probe UV-B Erythemal Local Noon Irradiance Monthly L3 Global 1x1.25 deg Lat/Lon Grid Version 8 data in ASCII format. (The...

  18. TOMS/Nimbus-7 UV-B Erythemal Local Noon Irradiance Daily L3 Global 1x1.25 deg Lat/Lon Grid V008

    Data.gov (United States)

    National Aeronautics and Space Administration — This data product contains TOMS/Nimbus-7 UV-B Erythemal Local Noon Irradiance Daily L3 Global 1x1.25 deg Lat/Lon Grid Version 8 data in ASCII format. The Total Ozone...

  19. Effects of different doses of gamma radiation in the conservation and in the physiochemical characteristics of carrot (Daucus carota L.) processed minimally

    International Nuclear Information System (INIS)

    Perecin, Thalita Neme; Arthur, Valter; Silva, Lucia Cristina Aparecida S.; Leite, Daniela Terenzi Stuchi; Wyler, Patricia . E- mail: tperecin@cena.usp.br

    2007-01-01

    The objective of the work was to evaluate the effect of different doses of gamma radiation on the characteristics physic-chemical of carrot (Daucus carota L.) processed minimally, seeking the increase of shelf life and decrease of the microbial load. The carrots were acquired in the commerce of Piracicaba city and taken to the laboratory of Foods Irradiation of CENA/USP, where they were washed in running water, peeled and cut in form of slices. The carrot slices were putted in solution of chlorinated water 15ml/L by 4 minutes, droughts and package in a plastic box of polypropylene. After they were conditioned in plastic containers . After they were irradiated in a source of Cobalt-60, type Gammacell-220 (dose rate of 0.725 kGy/hour) with the doses of: 0 (control), 1,0 and 2,0 kGy and stored in temperature of 5 deg C. They were analyzed: loss of fresh mass, the color (factors L, the, b), the pH, Brix and tetrable acidity, 4,10,16 and 22 days after the irradiation. The delineation experimental used was entirely at random with 10 repetitions for each treatment. By analyze of the obtained results concluded that the irradiation there was not difference significant statistics between the treatments with irradiation and the control. (author)

  20. Architecture of a minimal signaling pathway explains the T-cell response to a 1 million-fold variation in antigen affinity and dose

    Science.gov (United States)

    Lever, Melissa; Lim, Hong-Sheng; Kruger, Philipp; Nguyen, John; Trendel, Nicola; Abu-Shah, Enas; Maini, Philip Kumar; van der Merwe, Philip Anton

    2016-01-01

    T cells must respond differently to antigens of varying affinity presented at different doses. Previous attempts to map peptide MHC (pMHC) affinity onto T-cell responses have produced inconsistent patterns of responses, preventing formulations of canonical models of T-cell signaling. Here, a systematic analysis of T-cell responses to 1 million-fold variations in both pMHC affinity and dose produced bell-shaped dose–response curves and different optimal pMHC affinities at different pMHC doses. Using sequential model rejection/identification algorithms, we identified a unique, minimal model of cellular signaling incorporating kinetic proofreading with limited signaling coupled to an incoherent feed-forward loop (KPL-IFF) that reproduces these observations. We show that the KPL-IFF model correctly predicts the T-cell response to antigen copresentation. Our work offers a general approach for studying cellular signaling that does not require full details of biochemical pathways. PMID:27702900

  1. Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Jennifer L., E-mail: peterson.jennifer2@mayo.edu [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States); Buskirk, Steven J. [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States); Heckman, Michael G.; Diehl, Nancy N. [Section of Biostatistics, Mayo Clinic Florida, Jacksonville, FL (United States); Bernard, Johnny R. [Section of Biostatistics, Mayo Clinic Florida, Jacksonville, FL (United States); Department of Radiation Oncology, Southern Ohio Medical Center, Portsmouth, OH (United States); Tzou, Katherine S.; Casale, Henry E.; Bellefontaine, Louis P.; Serago, Christopher; Kim, Siyong; Vallow, Laura A.; Daugherty, Larry C.; Ko, Stephen J. [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States)

    2014-04-01

    Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm{sup 3} of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications.

  2. Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

    International Nuclear Information System (INIS)

    Peterson, Jennifer L.; Buskirk, Steven J.; Heckman, Michael G.; Diehl, Nancy N.; Bernard, Johnny R.; Tzou, Katherine S.; Casale, Henry E.; Bellefontaine, Louis P.; Serago, Christopher; Kim, Siyong; Vallow, Laura A.; Daugherty, Larry C.; Ko, Stephen J.

    2014-01-01

    Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm 3 of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications

  3. Direct comparison between the angular distributions of the erythemal and eye-damaging UV irradiances: a pilot study.

    Science.gov (United States)

    Schouten, P; Parisi, A V

    2011-02-07

    Several broadband ultraviolet (UV) radiation angular distribution investigations have been previously presented. As the biologically damaging effectiveness of UV radiation is known to be wavelength dependent, it is necessary to expand this research into the distribution of the spectral UV. UV radiation is also susceptible to Rayleigh and Mie scattering processes, both of which are completely wavelength dependent. Additionally, the majority of previous measurements detailing the biologically damaging effect of spectral UV radiation have been oriented with respect to the horizontal plane or in a plane directed towards the sun (sun-normal), with the irradiance weighted against action spectra formulated specifically for human skin and tissue. However, the human body consists of very few horizontal or sun-normal surfaces. Extending the previous research by measuring the distribution of the spectral irradiance across the sky for the complete terrestrial solar UV waveband and weighting it against erythemal, photoconjunctivital and photokeratital action spectra allowed for the analysis of the differences between the biologically effective irradiance (UV(BE)) values intercepted at different orientations and the effect of scattering processes upon the homogeneity of these UV(BE) distributions. It was established that under the local atmospheric environment, the distribution profile of the UV(BE) for each biological response was anisotropic, with the highest intensities generally intercepted at inclination angles situated between the horizontal and vertical planes along orientations closely coinciding with the sun-normal. A finding from this was that the angular distributions of the erythemal UV(BE) and the photoconjunctivital UV(BE) were different, due to the differential scattering between the shorter and longer UV wavelengths within the atmosphere. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. The minimal effective dose of cis-9-cetylmyristoleate (CMO) in persons presenting with knee joint pain: A double-blind, randomized, placebo-controlled trial.

    Science.gov (United States)

    Lee, Sang Chul; Jin, Hyun Seung; Joo, Young; Kim, Yong Chul; Moon, Jee Youn

    2017-03-01

    Nutraceuticals containing cis-9-cetylmyristoleate (CMO) are used to improve knee pain despite the lack of placebo-controlled studies in humans. The aim of the study was to explore the minimal effective dose of CMO for relieving knee joint pain. Twenty-eight subjects with mild degree arthritic knee joint pain were randomized into 4 groups; groups A, B, and C that contained 100%, 80%, and 62.4% of fatty acid component with 12.5% of CMO, and control group D (starch 100%). The pain intensity, functional disability, and the Patient Global Impression of Change (PGIC) were assessed for a 12-week ingestion period. Compared to group D (n = 6), there were significant differences in pain score in group A (n = 7, P = 0.005) and group C (n = 7, P = 0.012), but not significant in group B (n = 6, P = 0.180). Western Ontario and McMaster Universities Arthritis (WOMAC) score decreased significantly in groups A and C. The PGIC was positive in the majority (>50%) in groups A, B, and C, whereas negative in 83.3% in group D (control). CMO is effective in alleviating knee pain in persons with mild degree arthritis of the knee joint, at an effective dose of 62.4%.

  5. Optimal dose levels in screening chest CT for unimpaired detection and volumetry of lung nodules, with and without computer assisted detection at minimal patient radiation.

    Directory of Open Access Journals (Sweden)

    Andreas Christe

    Full Text Available OBJECTIVES: The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS: An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp. For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD software. RESULTS: The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%. No significant volume measurement errors (VMEs were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS: Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

  6. Application of low-dose gamma irradiation to extend the shelf life of minimally processed Red Beet (Beta vulgaris sp. vulgaris L.), cv. Early Wonder

    International Nuclear Information System (INIS)

    Hernandez, Nilber Kenup

    2006-01-01

    This study was aimed at investigating the effects of low-dose gamma irradiation on shelf-life extension and phyto sanitary safety of minimally processed red beet with basis on physicochemical; microbiological; chemical and sensory analyses. The samples (Beta vulgaris ssp. vulgaris L.), Early Wonder cultivar, were cultivated in the experimental area of the Horticulture Sector of the Departamento de Fitotecnia of the Instituto de Agronomia, Universidade Federal Rural do Rio de Janeiro, Seropedica, RJ, as part of two experiments performed during the second semester of 2005. In each experiment, 1200 plants (40 per linear meter of terrain) were sowed. Physicochemical analyses (fresh mass; length; average diameter and total soluble solids) of the edible part of the red beets (their tuberous roots) were periodically carried out in order to assess the most appropriate time for harvest by monitoring the development of the plants. Those times were found to be 104 and 73 days after transplanting, respectively. The harvested edible part of the roots were minimally processed and separated in two groups: (1) gamma irradiated (with doses of 0.5; 1.0 and 1.5 kGy) and (2) non-irradiated (control). All samples were stored at 8 degree C. Microbiological analyses were performed during the storage period (22 and 21 days, for experiments 1 and 2, respectively) in order to evaluate the phyto sanitary quality of the samples (Salmonella sp.; coliforms and total count of mesophilic aerobic and lactic acid bacteria). The samples irradiated with 1.0 and 1.5 kGy were found to remain appropriate for consumption for 21 days, as compared to only 7 days for the control. Monitoring of chemical composition was also performed and included the determination of saccharose; glucose; fructose and vitamins B1 and B2. No difference was found between the concentrations of those vitamins in irradiated and control samples at the end of the storage period, whereas significant changes in sugar contents were

  7. Effects of intensive induction and consolidation chemotherapy with idarubicin and high dose cytarabine on minimal residual disease levels in newly diagnosed adult precursor-B acute lymphoblastic leukemia

    Directory of Open Access Journals (Sweden)

    Kenneth F. Bradstock

    2016-12-01

    Full Text Available An intensive induction regimen, consisting of idarubicin and high dose cytarabine, was assessed in 19 adult patients, median age 44 years, with newly diagnosed precursor-B acute lymphoblastic leukemia (ALL. Patients achieving a complete response (CR were given an attenuated consolidation course. The primary endpoints were induction death rate and incidence of serious non-hematological toxicity. Grades 3–4 diarrhoea occurred in 47% of patients during induction. Two patients (11% died during induction therapy, and 2 were withdrawn due to resistant disease or prolonged marrow hypoplasia. Fifteen patients achieved CR (79%, but levels of minimal residual disease (MRD after induction were comparable with those previously observed using a modified pediatric protocol. Overall survival at 5 years was 36.8% while leukemia-free survival was 44.1%. An intensive AML protocol used in adults with ALL resulted in substantial toxicity and provided similar levels of cytoreduction to conventional ALL protocols, without improving long-term outcomes.

  8. Fractional sunburn threshold UVR doses generate equivalent vitamin D and DNA damage in skin types I-VI, but with epidermal DNA damage gradient correlated to skin darkness.

    Science.gov (United States)

    Shih, Barbara B; Farrar, Mark D; Cooke, Marcus S; Osman, Joanne; Langton, Abigail K; Kift, Richard; Webb, Ann R; Berry, Jacqueline L; Watson, Rachel E B; Vail, Andy; de Gruijl, Frank R; Rhodes, Lesley E

    2018-05-03

    Public health guidance recommends limiting sun-exposure to sub-sunburn levels, but it's unknown whether these can gain vitamin D (for musculoskeletal health) whilst avoiding epidermal DNA damage (initiates skin cancer). Well-characterised healthy humans of all skin types (I-VI; lightest to darkest skin) were exposed to a low dose-series of solar simulated UVR of 20-80% their individual sunburn threshold dose (minimal erythemal dose, MED). Significant UVR dose-responses were seen for serum 25(OH)D and whole epidermal CPD, with as little as 0.2 MED concurrently producing 25(OH)D and CPD. Notably, fractional MEDs generated equivalent levels of whole epidermal CPD and 25(OH)D across all skin types. Crucially, we demonstrated an epidermal gradient of CPD formation strongly correlated with skin darkness (r=0.74; Pskin types, ranging from darkest skin, where high CPD levels occurred superficially with none in the germinative basal layer, through to lightest skin where CPD were induced evenly across the epidermal depth. Darker skin people can be encouraged to utilise sub-sunburn UVR-exposure to enhance their vitamin D. In lighter skin people, basal cell damage occurs concurrent with vitamin D synthesis at exquisitely low UVR levels, providing an explanation for their high skin cancer incidence; greater caution is required. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hojin; Li Ruijiang; Lee, Rena; Goldstein, Thomas; Boyd, Stephen; Candes, Emmanuel; Xing Lei [Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States) and Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Ehwa University, Seoul 158-710 (Korea, Republic of); Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States); Department of Statistics, Stanford University, Stanford, California 94305-4065 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5304 (United States)

    2012-07-15

    Purpose: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem. Methods: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases. Results: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the

  10. Minimal surfaces

    CERN Document Server

    Dierkes, Ulrich; Sauvigny, Friedrich; Jakob, Ruben; Kuster, Albrecht

    2010-01-01

    Minimal Surfaces is the first volume of a three volume treatise on minimal surfaces (Grundlehren Nr. 339-341). Each volume can be read and studied independently of the others. The central theme is boundary value problems for minimal surfaces. The treatise is a substantially revised and extended version of the monograph Minimal Surfaces I, II (Grundlehren Nr. 295 & 296). The first volume begins with an exposition of basic ideas of the theory of surfaces in three-dimensional Euclidean space, followed by an introduction of minimal surfaces as stationary points of area, or equivalently

  11. The relationship between disability-adjusted life years of cataracts and ambient erythemal ultraviolet radiation in China.

    Science.gov (United States)

    Zhu, Min; Yu, Jiaming; Gao, Qian; Wang, Yang; Hu, Liwen; Zheng, Yang; Wang, Fang; Liu, Yang

    2015-01-01

    Cataracts are one of the major public health problems worldwide. Ultraviolet radiation (UVR) is one of the risk factors for cataract development. We analyzed the relationship between disability-adjusted life year (DALY) rates of cataracts and UVR exposure in China. DALY rates of cataracts and UVR exposure in 31 regions of China were calculated based on data from the Second China National Sample Survey on Disability and the United States' National Aeronautics and Space Administration database. The relationship between the DALY rates of cataracts and UVR was estimated by Spearman rank correlation analysis and linear regression analysis. The elderly (≥ 65 years) had higher DALY rates of cataracts than the whole population. The DALY rate of cataracts in the agricultural population was higher than that observed in the non-agricultural population. The DALY rates of cataracts were positively associated with UVR The DALY rates of cataracts in regions with higher UVR were higher than those in regions with lower UVR. An increase in the daily ambient erythemal UVR of 1000 J/m(2) was associated with an increase in the DALY rates of cataracts by 92 DALYs/100 000 (R(2) = 0.676) among the whole population, 34 DALYs/100 000 among the population population aged 65-74 years (R(2) = 0.617), and by 1342 DALYs/100 000 among the population ≥ 75 years old (R(2) = 0.758). DALY rates of cataracts increased with increases in UVR exposure in 31 regions of China. Greater exposure to UVR increases the disease burden of cataracts in the whole population, especially in the elderly and among the agricultural population.

  12. The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

    International Nuclear Information System (INIS)

    Perisinakis, Kostas; Seimenis, Ioannis; Tzedakis, Antonis; Papadakis, Antonios E.; Damilakis, John

    2013-01-01

    Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of

  13. A broad-spectrum sunscreen prevents cumulative damage from repeated exposure to sub-erythemal solar ultraviolet radiation representative of temperate latitudes.

    Science.gov (United States)

    Seité, S; Christiaens, F; Bredoux, C; Compan, D; Zucchi, H; Lombard, D; Fourtanier, A; Young, A R

    2010-02-01

    We have previously shown the detrimental effects of 19 sub-erythemal exposures to daily ultraviolet radiation (DUVR, which mimics non-extreme exposure conditions), delivered over 4 weeks to volunteers. This source had UVA (320-400 nm) to UVB (290-320 nm) irradiance ratio of 25, instead of that close to 10 that is typically the case with solar-simulated radiation (SSR) that represents summer global sunlight with a clear sky and quasi-zenith solar irradiance. Here, we report on an extension of this previous study, in which we evaluated the photoprotection afforded by a broad-spectrum daily-care product with a low-sun protection factor (SPF 8, UVA-PF 7 and 3* rated UVA protection). We assessed cellular and molecular markers of photodamage that are relevant to skin cancer and photoageing. This study shows that biological effects of repeated exposure to DUVR can be prevented by a broad-spectrum daily-care product and that the level of protection afforded varies with the studied endpoint. Efficient daily UVR protection, as provided by a broad-spectrum daily-care product, is necessary to prevent the 'silent' sub-erythemal cumulative effects of UVR from inadvertent sun exposure.

  14. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, Wolfgang [Multiorgan Screening Foundation, Frankfurt (Germany); University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany); University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg [University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Wiedemann, Baerbel [University Hospital Dresden, Institute of Medical Informatics and Biometrics, Dresden (Germany); Wehrmann, Ursula [University Hospital Dresden, Clinic and Policlinic of Surgery, Dresden (Germany); Koch, Arne; Abolmaali, Nasreddin [University Hospital Dresden, Oncoray, Dresden (Germany); Toussaint, Todd; Luboldt, Hans-Joachim [Multiorgan Screening Foundation, Frankfurt (Germany); Middendorp, Markus; Gruenwald, Frank [University Hospital Frankfurt, Department of Nuclear Medicine, Frankfurt (Germany); Aust, Daniela [University Hospital Dresden, Department of Pathology, Dresden (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany)

    2010-09-15

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas {>=}10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV{sub max} was {>=}5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV{sub max}. FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV{sub max}{>=} 5 improves the accuracy. (orig.)

  15. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg; Wiedemann, Baerbel; Wehrmann, Ursula; Koch, Arne; Abolmaali, Nasreddin; Toussaint, Todd; Luboldt, Hans-Joachim; Middendorp, Markus; Gruenwald, Frank; Aust, Daniela; Vogl, Thomas J.

    2010-01-01

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas ≥10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV max was ≥5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV max . FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV max ≥ 5 improves the accuracy. (orig.)

  16. Integrated pharmacokinetics/pharmacodynamics parameters-based dosing guidelines of enrofloxacin in grass carp Ctenopharyngodon idella to minimize selection of drug resistance.

    Science.gov (United States)

    Xu, Lijuan; Wang, Hao; Yang, Xianle; Lu, Liqun

    2013-06-25

    Antibiotic resistance has become a serious global problem and is steadily increasing worldwide in almost every bacterial species treated with antibiotics. In aquaculture, the therapeutic options for the treatment of A. hydrophila infection were only limited to several antibiotics, which contributed for the fast-speed emergence of drug tolerance. Accordingly, the aim of this study was to establish a medication regimen to prevent drug resistant bacteria. To determine a rational therapeutic guideline, integrated pharmacodynamics and pharmacokinetics parameters were based to predict dose and dosage interval of enrofloxacin in grass carp Ctenopharyngodon idella infected by a field-isolated A. hydrophila strain. The pathogenic A. hydrophila strain (AH10) in grass carp was identified and found to be sensitive to enrofloxacin. The mutant selection window (MSW) of enrofloxacin on isolate AH10 was determined to be 0.5-3 μg/mL based on the mutant prevention concentration (MPC) and minimum inhibitory concentration (MIC) value. By using high-performance liquid chromatography (HPLC) system, the Pharmacokinetic (PK) parameters of enrofloxacin and its metabolite ciprofloxacin in grass carp were monitored after a single oral gavage of 10, 20, 30 μg enrofloxacin per g body weight. Dosing of 30 μg/g resulted in serum maximum concentration (Cmax) of 7.151 μg/mL, and concentration in serum was above MPC till 24 h post the single dose. Once-daily dosing of 30 μg/g was determined to be the rational choice for controlling AH10 infection and preventing mutant selection in grass carp. Data of mean residue time (MRT) and body clearance (CLz) indicated that both enrofloxacin and its metabolite ciprofloxacin present similar eliminating rate and pattern in serum, muscle and liver. A withdraw time of more than 32 d was suggested based on the drug eliminating rate and pharmacokinetic model described by a polyexponential equation. Based on integrated PK/PD parameters (AUC/MIC, Cmax/MIC, and T

  17. Taxonomic minimalism.

    Science.gov (United States)

    Beattle, A J; Oliver, I

    1994-12-01

    Biological surveys are in increasing demand while taxonomic resources continue to decline. How much formal taxonomy is required to get the job done? The answer depends on the kind of job but it is possible that taxonomic minimalism, especially (1) the use of higher taxonomic ranks, (2) the use of morphospecies rather than species (as identified by Latin binomials), and (3) the involvement of taxonomic specialists only for training and verification, may offer advantages for biodiversity assessment, environmental monitoring and ecological research. As such, formal taxonomy remains central to the process of biological inventory and survey but resources may be allocated more efficiently. For example, if formal Identification is not required, resources may be concentrated on replication and increasing sample sizes. Taxonomic minimalism may also facilitate the inclusion in these activities of important but neglected groups, especially among the invertebrates, and perhaps even microorganisms. Copyright © 1994. Published by Elsevier Ltd.

  18. Synthesis of vitamin D and erythemal irradiance obtained with a multiband filter radiometer and annual variation analysis in Rio Gallegos, Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Orte, P F [ANPCyT (Argentina); Wolfram, E A; Salvador, J; D' Elia, R; Quel, E J [CEILAP (CITEFA-CONICET) Villa Martelli, Buenos Aires (Argentina); Paes Leme, N, E-mail: porte@citefa.gov.ar [Instituto Nacional de Pesquisas Espaciais (Brazil)

    2011-01-01

    In this paper we examined the annual variability of the erythemal solar radiation (a health risk) and the solar irradiance for synthesis of vitamin D (a health benefit) in Rio Gallegos, Argentina. We use ultraviolet radiation measurements made by a multiband filter radiometer GUV-541 and a Brewer spectrophotometer located at CEILAP-RG Station (CITEFA-CONICET) (51 deg. 33' S, 69 deg. 19' W). These measurements are weighted with action spectra published by the CIE (International Commission on Illumination). An action spectrum describes the relative effectiveness of different wavelengths in the generation of a particular biological response. The analyzed data correspond to September 2008-December 2009 period. The methodology used to obtain the erythemal irradiance and synthesis of vitamin D values combines irradiance measurements of a multiband filter radiometer with modeled values (output of radiative transfer model) and measurements of a Brewer spectrophotometer. This procedure increases the instrumental capabilities of this instrument. The synthesis of vitamin D and erythema are affected by UVB solar radiation. Therefore, its effect is strongly dependent of the stratospheric ozone amount, which undergoes large variations in the Rio Gallegos city due to ozone hole passage and its influence on these sub-polar latitudes. We observed that could exist cases of sunburn for reasonable exposure in abnormal situations of low total ozone column, resulting in high levels of ultraviolet radiation. Furthermore, the synthesis of vitamin D through exposure to ultraviolet radiation would be lower than the appropriate values to the majority of the year for these latitudes. Therefore it is important to evaluate the annual variation of these quantities realizing seasonal balance between this health risk and this health benefit.

  19. Synthesis of vitamin D and erythemal irradiance obtained with a multiband filter radiometer and annual variation analysis in Rio Gallegos, Argentina

    International Nuclear Information System (INIS)

    Orte, P F; Wolfram, E A; Salvador, J; D'Elia, R; Quel, E J; Paes Leme, N

    2011-01-01

    In this paper we examined the annual variability of the erythemal solar radiation (a health risk) and the solar irradiance for synthesis of vitamin D (a health benefit) in Rio Gallegos, Argentina. We use ultraviolet radiation measurements made by a multiband filter radiometer GUV-541 and a Brewer spectrophotometer located at CEILAP-RG Station (CITEFA-CONICET) (51 deg. 33' S, 69 deg. 19' W). These measurements are weighted with action spectra published by the CIE (International Commission on Illumination). An action spectrum describes the relative effectiveness of different wavelengths in the generation of a particular biological response. The analyzed data correspond to September 2008-December 2009 period. The methodology used to obtain the erythemal irradiance and synthesis of vitamin D values combines irradiance measurements of a multiband filter radiometer with modeled values (output of radiative transfer model) and measurements of a Brewer spectrophotometer. This procedure increases the instrumental capabilities of this instrument. The synthesis of vitamin D and erythema are affected by UVB solar radiation. Therefore, its effect is strongly dependent of the stratospheric ozone amount, which undergoes large variations in the Rio Gallegos city due to ozone hole passage and its influence on these sub-polar latitudes. We observed that could exist cases of sunburn for reasonable exposure in abnormal situations of low total ozone column, resulting in high levels of ultraviolet radiation. Furthermore, the synthesis of vitamin D through exposure to ultraviolet radiation would be lower than the appropriate values to the majority of the year for these latitudes. Therefore it is important to evaluate the annual variation of these quantities realizing seasonal balance between this health risk and this health benefit.

  20. Synthesis of vitamin D and erythemal irradiance obtained with a multiband filter radiometer and annual variation analysis in Río Gallegos, Argentina

    Science.gov (United States)

    Orte, P. F.; Wolfram, E. A.; Salvador, J.; D'Elia, R.; Paes Leme, N.; Quel, E. J.

    2011-01-01

    In this paper we examined the annual variability of the erythemal solar radiation (a health risk) and the solar irradiance for synthesis of vitamin D (a health benefit) in Río Gallegos, Argentina. We use ultraviolet radiation measurements made by a multiband filter radiometer GUV-541 and a Brewer spectrophotometer located at CEILAP-RG Station (CITEFA-CONICET) (51° 33' S, 69° 19' W). These measurements are weighted with action spectra published by the CIE (International Commission on Illumination). An action spectrum describes the relative effectiveness of different wavelengths in the generation of a particular biological response. The analyzed data correspond to September 2008-December 2009 period. The methodology used to obtain the erythemal irradiance and synthesis of vitamin D values combines irradiance measurements of a multiband filter radiometer with modeled values (output of radiative transfer model) and measurements of a Brewer spectrophotometer. This procedure increases the instrumental capabilities of this instrument. The synthesis of vitamin D and erythema are affected by UVB solar radiation. Therefore, its effect is strongly dependent of the stratospheric ozone amount, which undergoes large variations in the Río Gallegos city due to ozone hole passage and its influence on these sub-polar latitudes. We observed that could exist cases of sunburn for reasonable exposure in abnormal situations of low total ozone column, resulting in high levels of ultraviolet radiation. Furthermore, the synthesis of vitamin D through exposure to ultraviolet radiation would be lower than the appropriate values to the majority of the year for these latitudes. Therefore it is important to evaluate the annual variation of these quantities realizing seasonal balance between this health risk and this health benefit.

  1. Optimizing the radiation therapy dose prescription for pediatric medulloblastoma: minimizing the life years lost attributable to failure to control the disease and late complication risk.

    Science.gov (United States)

    Brodin, N Patrik; Vogelius, Ivan R; Björk-Eriksson, Thomas; Munck Af Rosenschöld, Per; Maraldo, Maja V; Aznar, Marianne C; Specht, Lena; Bentzen, Søren M

    2014-04-01

    A mathematical framework is presented for simultaneously quantifying and evaluating the trade-off between tumor control and late complications for risk-based radiation therapy (RT) decision-support. To demonstrate this, we estimate life years lost (LYL) attributable to tumor recurrence, late cardiac toxicity and secondary cancers for standard-risk pediatric medulloblastoma (MB) patients and compare the effect of dose re-distribution on a common scale. Total LYL were derived, based on the LYL attributable to radiation-induced late complications and the LYL from not controlling the primary disease. We compared the estimated LYL for three different treatments in 10 patients: 1) standard 3D conformal RT; 2) proton therapy; 3) risk-adaptive photon treatment lowering the dose to part of the craniospinal (CS) target volume situated close to critical risk organs. Late toxicity is important, with 0.75 LYL (95% CI 0.60-7.2 years) for standard uniform 24 Gy CS irradiation. However, recurrence risk dominates the total LYL with 14.2 years (95% CI 13.4-16.6 years). Compared to standard treatment, a risk-adapted strategy prescribing 12 Gy to the spinal volume encompassing the 1st-10th thoracic vertebrae (Th1-Th10), and 36 Gy to the remaining CS volume, estimated a LYL reduction of 0.90 years (95% CI -0.18-2.41 years). Proton therapy with 36 Gy to the whole CS volume was associated with significantly fewer LYL compared to the risk-adapted photon strategies, with a mean LYL difference of 0.50 years (95% CI 0.25-2.60 years). Optimization of RT prescription strategies considering both late complications and the risk of recurrence, an all-cause mortality dose painting approach, was demonstrated. The risk-adapted techniques compared favorably to the standard, and although in this context, the gain is small compared to estimated uncertainty, this study demonstrates a framework for all-cause mortality risk estimation, rather than evaluates direct clinical applicability of risk

  2. The use of 18F-Fluoro-deoxy-glucose positron emission tomography (18F-FDG PET as a non-invasive pharmacodynamic biomarker to determine the minimally pharmacologically active dose of AZD8835, a novel PI3Kα inhibitor.

    Directory of Open Access Journals (Sweden)

    Juliana Maynard

    Full Text Available The phosphatidyl inositol 3 kinase (PI3K, AKT and mammalian target of rapamycin (mTOR signal transduction pathway is frequently de-regulated and activated in human cancer and is an important therapeutic target. AZD8835 is a PI3K inhibitor, with selectivity against PI3K α and δ isoforms, which is currently in Phase 1 clinical trials. 18F-Fluoro-deoxy-glucose positron emission tomography (18F-FDG PET is a non-invasive pharmacodynamic imaging biomarker that has become an integral part of drug development. It has been used widely with PI3K inhibitors both clinically and pre-clinically because of the role of the PI3K pathway in glucose metabolism. In this study we investigated the potential of 18F-FDG PET as a non-invasive pharmacodynamic biomarker for AZD8835. We sought to understand if 18F-FDG PET could determine the minimally effective dose of AZD8835 and correlate with other pharmacodynamic biomarkers for validation of its use in clinical development. 18F-FDG PET scans were performed in nude mice in the BT474C breast xenograft model. Mice were fasted prior to imaging and static 18F-FDG PET was performed. Treatment groups received AZD8835 by oral gavage at a dose volume of 10ml/kg. Treatment groups received either 3, 6, 12.5, 25 or 50mg/kg AZD8835. Tumour growth was monitored throughout the study, and at the end of the imaging procedure, tumours were taken and a full pharmacodynamic analysis was performed.Results showed that AZD8835 reduced 18F-FDG uptake at a dose of 12.5, 25 and 50mg/kg with no significant reduction at doses of 3 and 6mg/kg. These results were consistent with other pharmacodynamics biomarkers measured and show 18F-FDG PET as a sensitive biomarker with the ability to determine the minimal effective dose of AZD8835.Our pre-clinical studies support the use of 18F-FDG PET imaging as a sensitive and non- invasive pharmacodynamic biomarker (understanding the role of PI3K signalling in glucose uptake for AZD8835 with a decrease in 18

  3. Optimizing the radiation therapy dose prescription for pediatric medulloblastoma: Minimizing the life years lost attributable to failure to control the disease and late complication risk

    DEFF Research Database (Denmark)

    Brodin, N. Patrik; Vogelius, Ivan R.; Bjork-Eriksson, Thomas

    2014-01-01

    Background. A mathematical framework is presented for simultaneously quantifying and evaluating the trade-off between tumor control and late complications for risk-based radiation therapy (RT) decision-support. To demonstrate this, we estimate life years lost (LYL) attributable to tumor recurrence...... is important, with 0.75 LYL (95% CI 0.60-7.2 years) for standard uniform 24 Gy CS irradiation. However, recurrence risk dominates the total LYL with 14.2 years (95% CI 13.4-16.6 years). Compared to standard treatment, a risk-adapted strategy prescribing 12 Gy to the spinal volume encompassing the 1st-10th......, late cardiac toxicity and secondary cancers for standard-risk pediatric medulloblastoma (MB) patients and compare the effect of dose re-distribution on a common scale. Methods. Total LYL were derived, based on the LYL attributable to radiation-induced late complications and the LYL from not controlling...

  4. Minimal dose of milk protein concentrate to enhance the anabolic signalling response to a single bout of resistance exercise; a randomised controlled trial.

    Science.gov (United States)

    Mitchell, Cameron J; Zeng, Nina; D'Souza, Randall F; Mitchell, Sarah M; Aasen, Kirsten; Fanning, Aaron C; Poppitt, Sally D; Cameron-Smith, David

    2017-01-01

    Resistance training is a potent stimulus to induce muscle hypertrophy. Supplemental protein intake is known to enhance gains in muscle mass through activation of the mammalian target of rapamycin complex 1 (mTORC1) pathway, which initiates protein translation. While the optimal dose of high quality protein to promote post exercise anabolism in young or older men has been investigated, little is known about the minimum doses of protein required to potentiate the resistance exercise activation of anabolic signalling in middle aged men. Twenty healthy men (46.3 ± 5.7 years, BMI: 23.9 ± 6.6 kg/m 2 ) completed a single bout of unilateral resistance exercise consisting of 4 sets of leg extension and press at 80% of 1 repetition maximum. Participants were randomised to consume either formulated milk product containing 9 g milk protein (FMP) or an isoenergetic carbohydrate placebo (CHO) immediately post exercise, in a double blind fashion. A single muscle biopsy was collected at pre-exercise baseline and then bilateral biopsies were collected 90 and 240 min after beverage consumption. P70S6K Thr389 phosphorylation was increased with exercise irrespective of group, P70S6K Thr421/Ser424 was increased with exercise only in the FMP group at 240 min. Likewise, rpS6 Ser235/236 phosphorylation was increased with exercise irrespective of group, rpS6 Ser240/244 increased to a greater extent following exercise in the FMP group. mRNA expression of the amino acid transporter, LAT1/ SLC7A5 increased with both exercise and beverage consumption irrespective of group. PAT1/ SLC36A1 , CAT1/ SLC7A1 and SNAT2/ SLC38A2 mRNA increased only after exercise regardless of group. Nine grams of milk protein is sufficient to augment some measures of downstream mTORC1 signalling after resistance exercise but does not potentiate exercise induced increases in amino acid transporter expression. Formulated products containing nine grams of milk protein would be expected stimulate muscle

  5. Minimal doses of a sequence-optimized transgene mediate high-level and long-term EPO expression in vivo: challenging CpG-free gene design.

    Science.gov (United States)

    Kosovac, D; Wild, J; Ludwig, C; Meissner, S; Bauer, A P; Wagner, R

    2011-02-01

    Advanced gene delivery techniques can be combined with rational gene design to further improve the efficiency of plasmid DNA (pDNA)-mediated transgene expression in vivo. Herein, we analyzed the influence of intragenic sequence modifications on transgene expression in vitro and in vivo using murine erythropoietin (mEPO) as a transgene model. A single electro-gene transfer of an RNA- and codon-optimized mEPOopt gene into skeletal muscle resulted in a 3- to 4-fold increase of mEPO production sustained for >1 year and triggered a significant increase in hematocrit and hemoglobin without causing adverse effects. mEPO expression and hematologic levels were significantly lower when using comparable amounts of the wild type (mEPOwt) gene and only marginal effects were induced by mEPOΔCpG lacking intragenic CpG dinucleotides, even at high pDNA amounts. Corresponding with these observations, in vitro analysis of transfected cells revealed a 2- to 3-fold increased (mEPOopt) and 50% decreased (mEPOΔCpG) erythropoietin expression compared with mEPOwt, respectively. RNA analyses demonstrated that the specific design of the transgene sequence influenced expression levels by modulating transcriptional activity and nuclear plus cytoplasmic RNA amounts rather than translation. In sum, whereas CpG depletion negatively interferes with efficient expression in postmitotic tissues, mEPOopt doses <0.5 μg were sufficient to trigger optimal long-term hematologic effects encouraging the use of sequence-optimized transgenes to further reduce effective pDNA amounts.

  6. Comparison of three techniques for evaluating skin erythemal response for determination of sun protection factors of sunscreens: high resolution laser Doppler imaging, colorimetry and visual scoring.

    Science.gov (United States)

    Wilhelm, K P; Kaspar, K; Funkel, O

    2001-04-01

    Sun protection factor (SPF) measurement is based on the determination of the minimal erythema dose (MED). The ratio of doses required to induce a minimal erythema between product-treated and untreated skin is defined as SPF. The aim of this study was to validate the conventionally used visual scoring with two non-invasive methods: high resolution laser Doppler imaging (HR-LDI) and colorimetry. Another goal was to check whether suberythemal reactions could be detected by means of HR-LDI measurements. Four sunscreens were selected. The measurements were made on the back of 10 subjects. A solar simulator SU 5000 (m.u.t., Wedel, Germany) served as radiation source. For the visual assessment, the erythema was defined according to COLIPA as the first perceptible, clearly defined unambiguous redness of the skin. For the colorimetric determination of the erythema, a Chromameter CR 300 (Minolta, Osaka, Japan) was used. The threshold for the colorimetry was chosen according to the COLIPA recommendation as an increase of the redness parameter delta a* = 2.5. For the non-contact perfusion measurements of skin blood flow, a two-dimensional high resolution laser Doppler imager (HR-LDI) (Lisca, Linköping, Sweden) was used. For the HR-LDI measurements, an optimal threshold perfusion needed to be established. For the HR-LDI measurements basal perfusion +1 standard deviation of all basal measurements was found to be a reliable threshold perfusion corresponding to the minimal erythema. Smaller thresholds, which would be necessary for detection of suberythemal responses, did not provide unambiguous data. All three methods, visual scoring, colorimetry and HR-LDI, produced similar SPFs for the test products with a variability of colorimetry are suitable, reliable and observer-independent methods for MED determination. However, they do not provide greater sensitivity and thus do not result in lower UV dose requirements for testing.

  7. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L3 Global 1.0x1.0 deg Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Aura-OMI Daily Gridded Surface UV Irradiance Product (OMUVBd) is now available from the NASA Goddard Earth Sciences Data and Information Services Center (GES...

  8. A long term study of the relations between erythemal UV-B irradiance, total ozone column, and aerosol optical depth at central Argentina

    Science.gov (United States)

    Palancar, Gustavo G.; Olcese, Luis E.; Achad, Mariana; López, María Laura; Toselli, Beatriz M.

    2017-09-01

    Global ultraviolet-B irradiance (UV-B, 280-315 nm) measurements made at the campus of the University of Córdoba, Argentina were analyzed to quantify the effects of ozone and aerosols on surface UV-B erythemal irradiance (UVER). The measurements have been carried out with a YES Pyranometer during the period 2000-2013. The effect of ozone and aerosols has been quantified by means of the Radiation Amplification Factor (RAF) and by an aerosol factor (AF, analogous to RAF), respectively. The overall mean RAF under cloudless conditions was (1.2 ± 0.3) %, ranging from 0.67 to 2.10% depending on solar zenith angle (SZA) and on Aerosol Optical Depth (AOD). The RAF increased with the SZA with a clear trend. Similarly, the aerosol effect under almost-constant ozone and SZA showed that, on average, a 1% increase in AOD forced a decrease of (0.15 ± 0.04) % in the UVER, with a range of 0.06 to 0.27 and no defined trend as a function of the SZA. To analyze the effect of absorbing aerosols, an effective single scattering albedo (SSA) was determined by comparing the experimental UVER with calculations carried out with the TUV radiative transfer model.

  9. In vitro erythemal UV-A protection factors of inorganic sunscreens distributed in aqueous media using carnauba wax-decyl oleate nanoparticles.

    Science.gov (United States)

    Villalobos-Hernández, J R; Müller-Goymann, C C

    2007-01-01

    This paper describes the in vitro photoprotection in the UV-A range, i.e. 320-400 nm obtained by the use of carnauba wax-decyl oleate nanoparticles either as encapsulation systems or as accompanying vehicles for inorganic sunscreens such as barium sulfate, strontium carbonate and titanium dioxide. Lipid-free inorganic sunscreen nanosuspensions, inorganic sunscreen-free wax-oil nanoparticle suspensions and wax-oil nanoparticle suspensions containing inorganic sunscreens dispersed either in their oil phase or their aqueous phase were prepared by high pressure homogenization. The in vitro erythemal UV-A protection factors (EUV-A PFs) of the nanosuspensions were calculated by means of a sun protection analyzer. EUV-A PFs being no higher than 4 were obtained by the encapsulation of barium sulfate and strontium carbonate, meanwhile by the distribution of titanium dioxide in presence of wax-oil nanoparticles, the EUV-A PFs varied between 2 and 19. The increase in the EUV-A PFs of the titanium dioxide obtained by the use of wax-oil nanoparticles demonstrated a better performance of the sun protection properties of this pigment in the UV-A region.

  10. The minimally tuned minimal supersymmetric standard model

    International Nuclear Information System (INIS)

    Essig, Rouven; Fortin, Jean-Francois

    2008-01-01

    The regions in the Minimal Supersymmetric Standard Model with the minimal amount of fine-tuning of electroweak symmetry breaking are presented for general messenger scale. No a priori relations among the soft supersymmetry breaking parameters are assumed and fine-tuning is minimized with respect to all the important parameters which affect electroweak symmetry breaking. The superpartner spectra in the minimally tuned region of parameter space are quite distinctive with large stop mixing at the low scale and negative squark soft masses at the high scale. The minimal amount of tuning increases enormously for a Higgs mass beyond roughly 120 GeV

  11. The minimal non-minimal standard model

    International Nuclear Information System (INIS)

    Bij, J.J. van der

    2006-01-01

    In this Letter I discuss a class of extensions of the standard model that have a minimal number of possible parameters, but can in principle explain dark matter and inflation. It is pointed out that the so-called new minimal standard model contains a large number of parameters that can be put to zero, without affecting the renormalizability of the model. With the extra restrictions one might call it the minimal (new) non-minimal standard model (MNMSM). A few hidden discrete variables are present. It is argued that the inflaton should be higher-dimensional. Experimental consequences for the LHC and the ILC are discussed

  12. Application of low-dose gamma irradiation to extend the shelf life of minimally processed Red Beet (Beta vulgaris sp. vulgaris L.), cv. Early Wonder; Aplicacao de baixas doses de radiacao gama para extensao da vida util de beterraba vermelha (Beta vulgaris ssp. vulgaris L.), cv. Early Wonder, minimamente processada

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Nilber Kenup

    2006-07-01

    This study was aimed at investigating the effects of low-dose gamma irradiation on shelf-life extension and phyto sanitary safety of minimally processed red beet with basis on physicochemical; microbiological; chemical and sensory analyses. The samples (Beta vulgaris ssp. vulgaris L.), Early Wonder cultivar, were cultivated in the experimental area of the Horticulture Sector of the Departamento de Fitotecnia of the Instituto de Agronomia, Universidade Federal Rural do Rio de Janeiro, Seropedica, RJ, as part of two experiments performed during the second semester of 2005. In each experiment, 1200 plants (40 per linear meter of terrain) were sowed. Physicochemical analyses (fresh mass; length; average diameter and total soluble solids) of the edible part of the red beets (their tuberous roots) were periodically carried out in order to assess the most appropriate time for harvest by monitoring the development of the plants. Those times were found to be 104 and 73 days after transplanting, respectively. The harvested edible part of the roots were minimally processed and separated in two groups: (1) gamma irradiated (with doses of 0.5; 1.0 and 1.5 kGy) and (2) non-irradiated (control). All samples were stored at 8 degree C. Microbiological analyses were performed during the storage period (22 and 21 days, for experiments 1 and 2, respectively) in order to evaluate the phyto sanitary quality of the samples (Salmonella sp.; coliforms and total count of mesophilic aerobic and lactic acid bacteria). The samples irradiated with 1.0 and 1.5 kGy were found to remain appropriate for consumption for 21 days, as compared to only 7 days for the control. Monitoring of chemical composition was also performed and included the determination of saccharose; glucose; fructose and vitamins B1 and B2. No difference was found between the concentrations of those vitamins in irradiated and control samples at the end of the storage period, whereas significant changes in sugar contents were

  13. Granzyme B mediates both direct and indirect cleavage of extracellular matrix in skin after chronic low-dose ultraviolet light irradiation.

    Science.gov (United States)

    Parkinson, Leigh G; Toro, Ana; Zhao, Hongyan; Brown, Keddie; Tebbutt, Scott J; Granville, David J

    2015-02-01

    Extracellular matrix (ECM) degradation is a hallmark of many chronic inflammatory diseases that can lead to a loss of function, aging, and disease progression. Ultraviolet light (UV) irradiation from the sun is widely considered as the major cause of visible human skin aging, causing increased inflammation and enhanced ECM degradation. Granzyme B (GzmB), a serine protease that is expressed by a variety of cells, accumulates in the extracellular milieu during chronic inflammation and cleaves a number of ECM proteins. We hypothesized that GzmB contributes to ECM degradation in the skin after UV irradiation through both direct cleavage of ECM proteins and indirectly through the induction of other proteinases. Wild-type and GzmB-knockout mice were repeatedly exposed to minimal erythemal doses of solar-simulated UV irradiation for 20 weeks. GzmB expression was significantly increased in wild-type treated skin compared to nonirradiated controls, colocalizing to keratinocytes and to an increased mast cell population. GzmB deficiency significantly protected against the formation of wrinkles and the loss of dermal collagen density, which was related to the cleavage of decorin, an abundant proteoglycan involved in collagen fibrillogenesis and integrity. GzmB also cleaved fibronectin, and GzmB-mediated fibronectin fragments increased the expression of collagen-degrading matrix metalloproteinase-1 (MMP-1) in fibroblasts. Collectively, these findings indicate a significant role for GzmB in ECM degradation that may have implications in many age-related chronic inflammatory diseases. © 2014 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  14. Minimal effective dose of phosphine to control the cashew root borer, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae Dose mínima efetiva de fosfina no controle da broca-da-raiz do cajueiro, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae

    Directory of Open Access Journals (Sweden)

    Ervino Bleicher

    2010-06-01

    Full Text Available The objective of this research was to determine, in field conditions, the minimal of phosphine effective dose for the cashew root borer control. Three experiments were set up at three different periods: August, October and November, 1994, to control the cashew root borer, Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae, in Piaui State, Brazil. One, two, three and six phosphine tablets of three gram each, per plant were tested. In the August essay, phosphine was inefficient to control the borer. In the October essay, control was achieved using as little as 2 tablets per plant and in November with one tablet per plant to control the adult borers in the soil. Higher efficiency was achieved when treatment was applied far away from the last rain, in other words, as soil dries out.Objetivou-se determinar, em condições de campo, a dose mínima de fosfina para o controle da broca da raiz do cajueiro. Foram instalados 3 experimentos em épocas distintas, sendo o primeiro em agosto, o segundo em outubro e o terceiro em novembro de 1994 para o controle de Marshallius bondari Rosado-Neto (Coleoptera: Curculionidae em cajueiro, Anacardium occidentale L. no município de Pio IX, Estado do Piauí. Foram testadas 1; 2; 3 e 6 pastilhas de fosfina na forma de fosfeto de alumínio, de 3 gramas cada, por planta. No ensaio conduzido em agosto nenhum tratamento foi eficiente para o controle de brocas adultas no solo. No ensaio instalado em outubro, a fosfina foi eficiente a partir de duas pastilhas por planta e no ensaio de novembro a partir de uma pastilha por planta para o controle de adultos no solo. A eficiência foi tanto maior quanto maior foi o tempo decorrido após a última chuva, estando, portanto, o solo mais seco.

  15. The physiological and phenotypic determinants of human tanning measured as change in skin colour following a single dose of ultraviolet B radiation.

    Science.gov (United States)

    Wong, Terence H; Jackson, Ian J; Rees, Jonathan L

    2010-07-01

    Experimental study of the in vivo kinetics of tanning in human skin has been limited by the difficulties in measuring changes in melanin pigmentation independent of the ultravioletinduced changes in erythema. The present study attempted to experimentally circumvent this issue. We have studied erythemal and tanning responses following a single exposure to a range of doses of ultraviolet B irradiation on the buttock and the lower back in 98 subjects. Erythema was assessed using reflectance techniques at 24 h and tanning measured as the L* spectrophotometric score at 7 days following noradrenaline iontophoresis. We show that dose (P skin colour (P skin colour (P = 0.0365) or, as an alternative to skin colour, skin type (P = 0.0193) predict tanning, with those with lighter skin tanning slightly more to a defined UVB dose. If erythema is factored into the regression, then only dose and body site remain significant predictors of tanning: therefore neither phototype nor pigmentary factors, such as baseline skin colour, or eye or hair colour, predict change in skin colour to a unit erythemal response.

  16. Regularity of Minimal Surfaces

    CERN Document Server

    Dierkes, Ulrich; Tromba, Anthony J; Kuster, Albrecht

    2010-01-01

    "Regularity of Minimal Surfaces" begins with a survey of minimal surfaces with free boundaries. Following this, the basic results concerning the boundary behaviour of minimal surfaces and H-surfaces with fixed or free boundaries are studied. In particular, the asymptotic expansions at interior and boundary branch points are derived, leading to general Gauss-Bonnet formulas. Furthermore, gradient estimates and asymptotic expansions for minimal surfaces with only piecewise smooth boundaries are obtained. One of the main features of free boundary value problems for minimal surfaces is t

  17. Safety and Effectiveness of two treatment regimes with tranexamic acid to minimize inflammatory response in elective cardiopulmonary bypass patients: a randomized double-blind, dose-dependent, phase IV clinical trial

    Directory of Open Access Journals (Sweden)

    Martín Beatriz

    2011-10-01

    Full Text Available Abstract Background In cardiopulmonary bypass (CPB patients, fibrinolysis may enhance postoperative inflammatory response. We aimed to determine whether an additional postoperative dose of antifibrinolytic tranexamic acid (TA reduced CPB-mediated inflammatory response (IR. Methods We performed a randomized, double-blind, dose-dependent, parallel-groups study of elective CPB patients receiving TA. Patients were randomly assigned to either the single-dose group (40 mg/Kg TA before CPB and placebo after CPB or the double-dose group (40 mg/Kg TA before and after CPB. Results 160 patients were included, 80 in each group. The incident rate of IR was significantly lower in the double-dose-group TA2 (7.5% vs. 18.8% in the single-dose group TA1; P = 0.030. After adjusting for hypertension, total protamine dose and temperature after CPB, TA2 showed a lower risk of IR compared with TA1 [OR: 0.29 (95% CI: 0.10-0.83, (P = 0.013]. Relative risk for IR was 2.5 for TA1 (95% CI: 1.02 to 6.12. The double-dose group had significantly lower chest tube bleeding at 24 hours [671 (95% CI 549-793 vs. 826 (95% CI 704-949 mL; P = 0.01 corrected-P significant] and lower D-dimer levels at 24 hours [489 (95% CI 437-540 vs. 621(95% CI: 563-679 ng/mL; P = 0.01 corrected-P significant]. TA2 required lower levels of norepinephrine at 24 h [0.06 (95% CI: 0.03-0.09 vs. 0.20(95 CI: 0.05-0.35 after adjusting for dobutamine [F = 6.6; P = 0.014 corrected-P significant]. We found a significant direct relationship between IL-6 and temperature (rho = 0.26; P P P P P P P Conclusions Prolonged inhibition of fibrinolysis, using an additional postoperative dose of tranexamic acid reduces inflammatory response and postoperative bleeding (but not transfusion requirements in CPB patients. A question which remains unanswered is whether the dose used was ideal in terms of safety, but not in terms of effectiveness. Current Controlled Trials number ISRCTN: ISRCTN84413719

  18. Feasible Dose Reduction in Routine Chest Computed Tomography Maintaining Constant Image Quality Using the Last Three Scanner Generations: From Filtered Back Projection to Sinogram-affirmed Iterative Reconstruction and Impact of the Novel Fully Integrated Detector Design Minimizing Electronic Noise

    Directory of Open Access Journals (Sweden)

    Lukas Ebner

    2014-01-01

    Full Text Available Objective:The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP and an iterative reconstruction (IR algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany was investigated. Materials and Methods: 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP, SOMATOM Definition Flash (IR, and SOMATOM Definition Edge (ICD and IR. Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. Results: Dose-length product (DLP with FBP for the average chest CT was 308 mGycm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGycm ± 68.8 (P = 0.0001. Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGycm ± 54.5 (P = 0.033. The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048. Overall contrast-to-noise ratio (CNR improved with declining DLP. Conclusion: The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

  19. Minimally invasive orthognathic surgery.

    Science.gov (United States)

    Resnick, Cory M; Kaban, Leonard B; Troulis, Maria J

    2009-02-01

    Minimally invasive surgery is defined as the discipline in which operative procedures are performed in novel ways to diminish the sequelae of standard surgical dissections. The goals of minimally invasive surgery are to reduce tissue trauma and to minimize bleeding, edema, and injury, thereby improving the rate and quality of healing. In orthognathic surgery, there are two minimally invasive techniques that can be used separately or in combination: (1) endoscopic exposure and (2) distraction osteogenesis. This article describes the historical developments of the fields of orthognathic surgery and minimally invasive surgery, as well as the integration of the two disciplines. Indications, techniques, and the most current outcome data for specific minimally invasive orthognathic surgical procedures are presented.

  20. Correlates of minimal dating.

    Science.gov (United States)

    Leck, Kira

    2006-10-01

    Researchers have associated minimal dating with numerous factors. The present author tested shyness, introversion, physical attractiveness, performance evaluation, anxiety, social skill, social self-esteem, and loneliness to determine the nature of their relationships with 2 measures of self-reported minimal dating in a sample of 175 college students. For women, shyness, introversion, physical attractiveness, self-rated anxiety, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. For men, physical attractiveness, observer-rated social skill, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. The patterns of relationships were not identical for the 2 indicators of minimal dating, indicating the possibility that minimal dating is not a single construct as researchers previously believed. The present author discussed implications and suggestions for future researchers.

  1. Hexavalent Chromium Minimization Strategy

    Science.gov (United States)

    2011-05-01

    Logistics 4 Initiative - DoD Hexavalent Chromium Minimization Non- Chrome Primer IIEXAVAJ ENT CHRO:M I~UMI CHROMIUM (VII Oil CrfVli.J CANCEfl HAnRD CD...Management Office of the Secretary of Defense Hexavalent Chromium Minimization Strategy Report Documentation Page Form ApprovedOMB No. 0704-0188...00-2011 4. TITLE AND SUBTITLE Hexavalent Chromium Minimization Strategy 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  2. Minimal Super Technicolor

    DEFF Research Database (Denmark)

    Antola, M.; Di Chiara, S.; Sannino, F.

    2011-01-01

    We introduce novel extensions of the Standard Model featuring a supersymmetric technicolor sector (supertechnicolor). As the first minimal conformal supertechnicolor model we consider N=4 Super Yang-Mills which breaks to N=1 via the electroweak interactions. This is a well defined, economical......, between unparticle physics and Minimal Walking Technicolor. We consider also other N =1 extensions of the Minimal Walking Technicolor model. The new models allow all the standard model matter fields to acquire a mass....

  3. Minimizing Mutual Couping

    DEFF Research Database (Denmark)

    2010-01-01

    Disclosed herein are techniques, systems, and methods relating to minimizing mutual coupling between a first antenna and a second antenna.......Disclosed herein are techniques, systems, and methods relating to minimizing mutual coupling between a first antenna and a second antenna....

  4. Ruled Laguerre minimal surfaces

    KAUST Repository

    Skopenkov, Mikhail; Pottmann, Helmut; Grohs, Philipp

    2011-01-01

    A Laguerre minimal surface is an immersed surface in ℝ 3 being an extremal of the functional ∫ (H 2/K-1)dA. In the present paper, we prove that the only ruled Laguerre minimal surfaces are up to isometry the surfaces ℝ (φλ) = (Aφ, Bφ, Cφ + D cos 2φ

  5. Strategies to eradicate minimal residual disease in small cell lung cancer: high-dose chemotherapy with autologous bone marrow transplantation, matrix metalloproteinase inhibitors, and BEC2 plus BCG vaccination.

    Science.gov (United States)

    Krug, L M; Grant, S C; Miller, V A; Ng, K K; Kris, M G

    1999-10-01

    In the last 25 years, treatment for small cell lung cancer (SCLC) has improved with advances in chemotherapy and radiotherapy. Standard chemotherapy regimens can yield 80% to 90% response rates and some cures when combined with thoracic irradiation in limited-stage patients. Nonetheless, small cell lung cancer has a high relapse rate due to drug resistance; this has resulted in poor survival for most patients. Attacking this problem requires a unique approach to eliminate resistant disease remaining after induction therapy. This review will focus on three potential strategies: high-dose chemotherapy with autologous bone marrow transplantation, matrix metalloproteinase inhibitors, and BEC2 plus BCG vaccination.

  6. Minimizing Exposure at Work

    Science.gov (United States)

    ; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Home Page Pesticide Health and Safety Information Safe Use Practices Minimizing Exposure at Work Pesticides - Pennsylvania State University Cooperative Extension Personal Protective Equipment for Working

  7. Minimalism. Clip and Save.

    Science.gov (United States)

    Hubbard, Guy

    2002-01-01

    Provides background information on the art movement called "Minimalism" discussing why it started and its characteristics. Includes learning activities and information on the artist, Donald Judd. Includes a reproduction of one of his art works and discusses its content. (CMK)

  8. Ruled Laguerre minimal surfaces

    KAUST Repository

    Skopenkov, Mikhail

    2011-10-30

    A Laguerre minimal surface is an immersed surface in ℝ 3 being an extremal of the functional ∫ (H 2/K-1)dA. In the present paper, we prove that the only ruled Laguerre minimal surfaces are up to isometry the surfaces ℝ (φλ) = (Aφ, Bφ, Cφ + D cos 2φ) + λ(sin φ, cos φ, 0), where A,B,C,D ε ℝ are fixed. To achieve invariance under Laguerre transformations, we also derive all Laguerre minimal surfaces that are enveloped by a family of cones. The methodology is based on the isotropic model of Laguerre geometry. In this model a Laguerre minimal surface enveloped by a family of cones corresponds to a graph of a biharmonic function carrying a family of isotropic circles. We classify such functions by showing that the top view of the family of circles is a pencil. © 2011 Springer-Verlag.

  9. Minimal and careful processing

    OpenAIRE

    Nielsen, Thorkild

    2004-01-01

    In several standards, guidelines and publications, organic food processing is strongly associated with "minimal processing" and "careful processing". The term "minimal processing" is nowadays often used in the general food processing industry and described in literature. The term "careful processing" is used more specifically within organic food processing but is not yet clearly defined. The concept of carefulness seems to fit very well with the processing of organic foods, especially if it i...

  10. Waste minimization assessment procedure

    International Nuclear Information System (INIS)

    Kellythorne, L.L.

    1993-01-01

    Perry Nuclear Power Plant began developing a waste minimization plan early in 1991. In March of 1991 the plan was documented following a similar format to that described in the EPA Waste Minimization Opportunity Assessment Manual. Initial implementation involved obtaining management's commitment to support a waste minimization effort. The primary assessment goal was to identify all hazardous waste streams and to evaluate those streams for minimization opportunities. As implementation of the plan proceeded, non-hazardous waste streams routinely generated in large volumes were also evaluated for minimization opportunities. The next step included collection of process and facility data which would be useful in helping the facility accomplish its assessment goals. This paper describes the resources that were used and which were most valuable in identifying both the hazardous and non-hazardous waste streams that existed on site. For each material identified as a waste stream, additional information regarding the materials use, manufacturer, EPA hazardous waste number and DOT hazard class was also gathered. Once waste streams were evaluated for potential source reduction, recycling, re-use, re-sale, or burning for heat recovery, with disposal as the last viable alternative

  11. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    International Nuclear Information System (INIS)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-01-01

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes

  12. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    Energy Technology Data Exchange (ETDEWEB)

    Sciahbasi, Alessandro, E-mail: alessandro.sciahbasi@fastwebnet.it [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Calabrò, Paolo [Division of Cardiology - Department of Cardio-Thoracic Sciences - Second University of Naples (Italy); Sarandrea, Alessandro [HSE Management, Rome (Italy); Rigattieri, Stefano [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Tomassini, Francesco [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Sardella, Gennaro [La Sapienza University, Rome (Italy); Zavalloni, Dennis [UO Emodinamica e Cardiologia Invasiva, IRCCS, Istituto Clinico Humanitas, Rozzano (Italy); Cortese, Bernardo [Interventional Cardiology, Fatebenefratelli Hospital, Milan (Italy); Limbruno, Ugo [Cardiology Unit, Misericordia Hospital, Grosseto (Italy); Tebaldi, Matteo [Cardiology Department, University of Ferrara, Department of Cardiology (Italy); Gagnor, Andrea [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Rubartelli, Paolo [Villa Scassi Hospital, Genova (Italy); Zingarelli, Antonio [San Martino Hospital, Genova (Italy); Valgimigli, Marco [Thoraxcenter, Rotterdam (Netherlands)

    2014-06-15

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes.

  13. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).

    Science.gov (United States)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-06-01

    Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Minimal quantization and confinement

    International Nuclear Information System (INIS)

    Ilieva, N.P.; Kalinowskij, Yu.L.; Nguyen Suan Han; Pervushin, V.N.

    1987-01-01

    A ''minimal'' version of the Hamiltonian quantization based on the explicit solution of the Gauss equation and on the gauge-invariance principle is considered. By the example of the one-particle Green function we show that the requirement for gauge invariance leads to relativistic covariance of the theory and to more proper definition of the Faddeev - Popov integral that does not depend on the gauge choice. The ''minimal'' quantization is applied to consider the gauge-ambiguity problem and a new topological mechanism of confinement

  15. Minimal Composite Inflation

    DEFF Research Database (Denmark)

    Channuie, Phongpichit; Jark Joergensen, Jakob; Sannino, Francesco

    2011-01-01

    We investigate models in which the inflaton emerges as a composite field of a four dimensional, strongly interacting and nonsupersymmetric gauge theory featuring purely fermionic matter. We show that it is possible to obtain successful inflation via non-minimal coupling to gravity, and that the u......We investigate models in which the inflaton emerges as a composite field of a four dimensional, strongly interacting and nonsupersymmetric gauge theory featuring purely fermionic matter. We show that it is possible to obtain successful inflation via non-minimal coupling to gravity...

  16. Minimalism and Speakers’ Intuitions

    Directory of Open Access Journals (Sweden)

    Matías Gariazzo

    2011-08-01

    Full Text Available Minimalism proposes a semantics that does not account for speakers’ intuitions about the truth conditions of a range of sentences or utterances. Thus, a challenge for this view is to offer an explanation of how its assignment of semantic contents to these sentences is grounded in their use. Such an account was mainly offered by Soames, but also suggested by Cappelen and Lepore. The article criticizes this explanation by presenting four kinds of counterexamples to it, and arrives at the conclusion that minimalism has not successfully answered the above-mentioned challenge.

  17. Minimal open strings

    International Nuclear Information System (INIS)

    Hosomichi, Kazuo

    2008-01-01

    We study FZZT-branes and open string amplitudes in (p, q) minimal string theory. We focus on the simplest boundary changing operators in two-matrix models, and identify the corresponding operators in worldsheet theory through the comparison of amplitudes. Along the way, we find a novel linear relation among FZZT boundary states in minimal string theory. We also show that the boundary ground ring is realized on physical open string operators in a very simple manner, and discuss its use for perturbative computation of higher open string amplitudes.

  18. Synoptic ozone, cloud reflectivity, and erythemal irradiance from sunrise to sunset for the whole earth as viewed by the DSCOVR spacecraft from the earth–sun Lagrange 1 orbit

    Directory of Open Access Journals (Sweden)

    J. Herman

    2018-01-01

    Full Text Available EPIC (Earth Polychromatic Imaging Camera on board the DSCOVR (Deep Space Climate Observatory spacecraft is the first earth science instrument located near the earth–sun gravitational plus centrifugal force balance point, Lagrange 1. EPIC measures earth-reflected radiances in 10 wavelength channels ranging from 317.5 to 779.5 nm. Of these channels, four are in the UV range 317.5, 325, 340, and 388 nm, which are used to retrieve O3, 388 nm scene reflectivity (LER: Lambert equivalent reflectivity, SO2, and aerosol properties. These new synoptic quantities are retrieved for the entire sunlit globe from sunrise to sunset multiple times per day as the earth rotates in EPIC's field of view. Retrieved ozone amounts agree with ground-based measurements and satellite data to within 3 %. The ozone amounts and LER are combined to derive the erythemal irradiance for the earth's entire sunlit surface at a nadir resolution of 18 × 18 km2 using a computationally efficient approximation to a radiative transfer calculation of irradiance. The results show very high summertime values of the UV index (UVI in the Andes and Himalayas (greater than 18, and high values of UVI near the Equator at equinox.

  19. Minimal model holography

    International Nuclear Information System (INIS)

    Gaberdiel, Matthias R; Gopakumar, Rajesh

    2013-01-01

    We review the duality relating 2D W N minimal model conformal field theories, in a large-N ’t Hooft like limit, to higher spin gravitational theories on AdS 3 . This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Higher spin theories and holography’. (review)

  20. Minimal constrained supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Cribiori, N. [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Dall' Agata, G., E-mail: dallagat@pd.infn.it [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Farakos, F. [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Porrati, M. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States)

    2017-01-10

    We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  1. Hazardous waste minimization

    International Nuclear Information System (INIS)

    Freeman, H.

    1990-01-01

    This book presents an overview of waste minimization. Covers applications of technology to waste reduction, techniques for implementing programs, incorporation of programs into R and D, strategies for private industry and the public sector, and case studies of programs already in effect

  2. Minimally invasive distal pancreatectomy

    NARCIS (Netherlands)

    Røsok, Bård I.; de Rooij, Thijs; van Hilst, Jony; Diener, Markus K.; Allen, Peter J.; Vollmer, Charles M.; Kooby, David A.; Shrikhande, Shailesh V.; Asbun, Horacio J.; Barkun, Jeffrey; Besselink, Marc G.; Boggi, Ugo; Conlon, Kevin; Han, Ho Seong; Hansen, Paul; Kendrick, Michael L.; Kooby, David; Montagnini, Andre L.; Palanivelu, Chinnasamy; Wakabayashi, Go; Zeh, Herbert J.

    2017-01-01

    The first International conference on Minimally Invasive Pancreas Resection was arranged in conjunction with the annual meeting of the International Hepato-Pancreato-Biliary Association (IHPBA), in Sao Paulo, Brazil on April 19th 2016. The presented evidence and outcomes resulting from the session

  3. Minimal DBM Substraction

    DEFF Research Database (Denmark)

    David, Alexandre; Håkansson, John; G. Larsen, Kim

    In this paper we present an algorithm to compute DBM substractions with a guaranteed minimal number of splits and disjoint DBMs to avoid any redundance. The substraction is one of the few operations that result in a non-convex zone, and thus, requires splitting. It is of prime importance to reduce...

  4. Minimal constrained supergravity

    Directory of Open Access Journals (Sweden)

    N. Cribiori

    2017-01-01

    Full Text Available We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  5. Minimal constrained supergravity

    International Nuclear Information System (INIS)

    Cribiori, N.; Dall'Agata, G.; Farakos, F.; Porrati, M.

    2017-01-01

    We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  6. Minimal abdominal incisions

    Directory of Open Access Journals (Sweden)

    João Carlos Magi

    2017-04-01

    Full Text Available Minimally invasive procedures aim to resolve the disease with minimal trauma to the body, resulting in a rapid return to activities and in reductions of infection, complications, costs and pain. Minimally incised laparotomy, sometimes referred to as minilaparotomy, is an example of such minimally invasive procedures. The aim of this study is to demonstrate the feasibility and utility of laparotomy with minimal incision based on the literature and exemplifying with a case. The case in question describes reconstruction of the intestinal transit with the use of this incision. Male, young, HIV-positive patient in a late postoperative of ileotiflectomy, terminal ileostomy and closing of the ascending colon by an acute perforating abdomen, due to ileocolonic tuberculosis. The barium enema showed a proximal stump of the right colon near the ileostomy. The access to the cavity was made through the orifice resulting from the release of the stoma, with a lateral-lateral ileo-colonic anastomosis with a 25 mm circular stapler and manual closure of the ileal stump. These surgeries require their own tactics, such as rigor in the lysis of adhesions, tissue traction, and hemostasis, in addition to requiring surgeon dexterity – but without the need for investments in technology; moreover, the learning curve is reported as being lower than that for videolaparoscopy. Laparotomy with minimal incision should be considered as a valid and viable option in the treatment of surgical conditions. Resumo: Procedimentos minimamente invasivos visam resolver a doença com o mínimo de trauma ao organismo, resultando em retorno rápido às atividades, reduções nas infecções, complicações, custos e na dor. A laparotomia com incisão mínima, algumas vezes referida como minilaparotomia, é um exemplo desses procedimentos minimamente invasivos. O objetivo deste trabalho é demonstrar a viabilidade e utilidade das laparotomias com incisão mínima com base na literatura e

  7. Minimal Walking Technicolor

    DEFF Research Database (Denmark)

    Foadi, Roshan; Frandsen, Mads Toudal; A. Ryttov, T.

    2007-01-01

    Different theoretical and phenomenological aspects of the Minimal and Nonminimal Walking Technicolor theories have recently been studied. The goal here is to make the models ready for collider phenomenology. We do this by constructing the low energy effective theory containing scalars......, pseudoscalars, vector mesons and other fields predicted by the minimal walking theory. We construct their self-interactions and interactions with standard model fields. Using the Weinberg sum rules, opportunely modified to take into account the walking behavior of the underlying gauge theory, we find...... interesting relations for the spin-one spectrum. We derive the electroweak parameters using the newly constructed effective theory and compare the results with the underlying gauge theory. Our analysis is sufficiently general such that the resulting model can be used to represent a generic walking technicolor...

  8. A perturbation technique for shield weight minimization

    International Nuclear Information System (INIS)

    Watkins, E.F.; Greenspan, E.

    1993-01-01

    The radiation shield optimization code SWAN (Ref. 1) was originally developed for minimizing the thickness of a shield that will meet a given dose (or another) constraint or for extremizing a performance parameter of interest (e.g., maximizing energy multiplication or minimizing dose) while maintaining the shield volume constraint. The SWAN optimization process proved to be highly effective (e.g., see Refs. 2, 3, and 4). The purpose of this work is to investigate the applicability of the SWAN methodology to problems in which the weight rather than the volume is the relevant shield characteristic. Such problems are encountered in shield design for space nuclear power systems. The investigation is carried out using SWAN with the coupled neutron-photon cross-section library FLUNG (Ref. 5)

  9. Legal incentives for minimizing waste

    International Nuclear Information System (INIS)

    Clearwater, S.W.; Scanlon, J.M.

    1991-01-01

    Waste minimization, or pollution prevention, has become an integral component of federal and state environmental regulation. Minimizing waste offers many economic and public relations benefits. In addition, waste minimization efforts can also dramatically reduce potential criminal requirements. This paper addresses the legal incentives for minimizing waste under current and proposed environmental laws and regulations

  10. The ZOOM minimization package

    International Nuclear Information System (INIS)

    Fischler, Mark S.; Sachs, D.

    2004-01-01

    A new object-oriented Minimization package is available for distribution in the same manner as CLHEP. This package, designed for use in HEP applications, has all the capabilities of Minuit, but is a re-write from scratch, adhering to modern C++ design principles. A primary goal of this package is extensibility in several directions, so that its capabilities can be kept fresh with as little maintenance effort as possible. This package is distinguished by the priority that was assigned to C++ design issues, and the focus on producing an extensible system that will resist becoming obsolete

  11. Minimizing the Pacman effect

    International Nuclear Information System (INIS)

    Ritson, D.; Chou, W.

    1997-10-01

    The Pacman bunches will experience two deleterious effects: tune shift and orbit displacement. It is known that the tune shift can be compensated by arranging crossing planes 900 relative to each other at successive interaction points (lPs). This paper gives an analytical estimate of the Pacman orbit displacement for a single as well as for two crossings. For the latter, it can be minimized by using equal phase advances from one IP to another. In the LHC, this displacement is in any event small and can be neglected

  12. Minimally Invasive Parathyroidectomy

    Directory of Open Access Journals (Sweden)

    Lee F. Starker

    2011-01-01

    Full Text Available Minimally invasive parathyroidectomy (MIP is an operative approach for the treatment of primary hyperparathyroidism (pHPT. Currently, routine use of improved preoperative localization studies, cervical block anesthesia in the conscious patient, and intraoperative parathyroid hormone analyses aid in guiding surgical therapy. MIP requires less surgical dissection causing decreased trauma to tissues, can be performed safely in the ambulatory setting, and is at least as effective as standard cervical exploration. This paper reviews advances in preoperative localization, anesthetic techniques, and intraoperative management of patients undergoing MIP for the treatment of pHPT.

  13. Minimal conformal model

    Energy Technology Data Exchange (ETDEWEB)

    Helmboldt, Alexander; Humbert, Pascal; Lindner, Manfred; Smirnov, Juri [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2016-07-01

    The gauge hierarchy problem is one of the crucial drawbacks of the standard model of particle physics (SM) and thus has triggered model building over the last decades. Its most famous solution is the introduction of low-scale supersymmetry. However, without any significant signs of supersymmetric particles at the LHC to date, it makes sense to devise alternative mechanisms to remedy the hierarchy problem. One such mechanism is based on classically scale-invariant extensions of the SM, in which both the electroweak symmetry and the (anomalous) scale symmetry are broken radiatively via the Coleman-Weinberg mechanism. Apart from giving an introduction to classically scale-invariant models, the talk presents our results on obtaining a theoretically consistent minimal extension of the SM, which reproduces the correct low-scale phenomenology.

  14. Minimal Reducts with Grasp

    Directory of Open Access Journals (Sweden)

    Iris Iddaly Mendez Gurrola

    2011-03-01

    Full Text Available The proper detection of patient level of dementia is important to offer the suitable treatment. The diagnosis is based on certain criteria, reflected in the clinical examinations. From these examinations emerge the limitations and the degree in which each patient is in. In order to reduce the total of limitations to be evaluated, we used the rough set theory, this theory has been applied in areas of the artificial intelligence such as decision analysis, expert systems, knowledge discovery, classification with multiple attributes. In our case this theory is applied to find the minimal limitations set or reduct that generate the same classification that considering all the limitations, to fulfill this purpose we development an algorithm GRASP (Greedy Randomized Adaptive Search Procedure.

  15. Minimally extended SILH

    International Nuclear Information System (INIS)

    Chala, Mikael; Grojean, Christophe; Humboldt-Univ. Berlin; Lima, Leonardo de; Univ. Estadual Paulista, Sao Paulo

    2017-03-01

    Higgs boson compositeness is a phenomenologically viable scenario addressing the hierarchy problem. In minimal models, the Higgs boson is the only degree of freedom of the strong sector below the strong interaction scale. We present here the simplest extension of such a framework with an additional composite spin-zero singlet. To this end, we adopt an effective field theory approach and develop a set of rules to estimate the size of the various operator coefficients, relating them to the parameters of the strong sector and its structural features. As a result, we obtain the patterns of new interactions affecting both the new singlet and the Higgs boson's physics. We identify the characteristics of the singlet field which cause its effects on Higgs physics to dominate over the ones inherited from the composite nature of the Higgs boson. Our effective field theory construction is supported by comparisons with explicit UV models.

  16. Minimally extended SILH

    Energy Technology Data Exchange (ETDEWEB)

    Chala, Mikael [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Valencia Univ. (Spain). Dept. de Fisica Teorica y IFIC; Durieux, Gauthier; Matsedonskyi, Oleksii [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Grojean, Christophe [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Humboldt-Univ. Berlin (Germany). Inst. fuer Physik; Lima, Leonardo de [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Univ. Estadual Paulista, Sao Paulo (Brazil). Inst. de Fisica Teorica

    2017-03-15

    Higgs boson compositeness is a phenomenologically viable scenario addressing the hierarchy problem. In minimal models, the Higgs boson is the only degree of freedom of the strong sector below the strong interaction scale. We present here the simplest extension of such a framework with an additional composite spin-zero singlet. To this end, we adopt an effective field theory approach and develop a set of rules to estimate the size of the various operator coefficients, relating them to the parameters of the strong sector and its structural features. As a result, we obtain the patterns of new interactions affecting both the new singlet and the Higgs boson's physics. We identify the characteristics of the singlet field which cause its effects on Higgs physics to dominate over the ones inherited from the composite nature of the Higgs boson. Our effective field theory construction is supported by comparisons with explicit UV models.

  17. Minimal erythema dose and minimal melanogenesis dose relate better to objectively measured skin type than to Fitzpatricks skin type

    DEFF Research Database (Denmark)

    Wulf, Hans Christian; Philipsen, Peter A; Ravnbak, Mette H

    2010-01-01

    Fitzpatrick skin type (FST I-IV) is a subjective expression of ultraviolet (UV) sensitivity based on erythema and tanning reactivity after a single exposure. Pigment protection factor (PPF) is an objective measurement of skin sensitivity in all skin types after a single exposure....

  18. Minimal Marking: A Success Story

    Science.gov (United States)

    McNeilly, Anne

    2014-01-01

    The minimal-marking project conducted in Ryerson's School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The "minimal-marking" concept (Haswell, 1983), which requires…

  19. Swarm robotics and minimalism

    Science.gov (United States)

    Sharkey, Amanda J. C.

    2007-09-01

    Swarm Robotics (SR) is closely related to Swarm Intelligence, and both were initially inspired by studies of social insects. Their guiding principles are based on their biological inspiration and take the form of an emphasis on decentralized local control and communication. Earlier studies went a step further in emphasizing the use of simple reactive robots that only communicate indirectly through the environment. More recently SR studies have moved beyond these constraints to explore the use of non-reactive robots that communicate directly, and that can learn and represent their environment. There is no clear agreement in the literature about how far such extensions of the original principles could go. Should there be any limitations on the individual abilities of the robots used in SR studies? Should knowledge of the capabilities of social insects lead to constraints on the capabilities of individual robots in SR studies? There is a lack of explicit discussion of such questions, and researchers have adopted a variety of constraints for a variety of reasons. A simple taxonomy of swarm robotics is presented here with the aim of addressing and clarifying these questions. The taxonomy distinguishes subareas of SR based on the emphases and justifications for minimalism and individual simplicity.

  20. Minimal dilaton model

    Directory of Open Access Journals (Sweden)

    Oda Kin-ya

    2013-05-01

    Full Text Available Both the ATLAS and CMS experiments at the LHC have reported the observation of the particle of mass around 125 GeV which is consistent to the Standard Model (SM Higgs boson, but with an excess of events beyond the SM expectation in the diphoton decay channel at each of them. There still remains room for a logical possibility that we are not seeing the SM Higgs but something else. Here we introduce the minimal dilaton model in which the LHC signals are explained by an extra singlet scalar of the mass around 125 GeV that slightly mixes with the SM Higgs heavier than 600 GeV. When this scalar has a vacuum expectation value well beyond the electroweak scale, it can be identified as a linearly realized version of a dilaton field. Though the current experimental constraints from the Higgs search disfavors such a region, the singlet scalar model itself still provides a viable alternative to the SM Higgs in interpreting its search results.

  1. Minimal mirror twin Higgs

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Riccardo [Institute of Theoretical Studies, ETH Zurich,CH-8092 Zurich (Switzerland); Scuola Normale Superiore,Piazza dei Cavalieri 7, 56126 Pisa (Italy); Hall, Lawrence J.; Harigaya, Keisuke [Department of Physics, University of California,Berkeley, California 94720 (United States); Theoretical Physics Group, Lawrence Berkeley National Laboratory,Berkeley, California 94720 (United States)

    2016-11-29

    In a Mirror Twin World with a maximally symmetric Higgs sector the little hierarchy of the Standard Model can be significantly mitigated, perhaps displacing the cutoff scale above the LHC reach. We show that consistency with observations requires that the Z{sub 2} parity exchanging the Standard Model with its mirror be broken in the Yukawa couplings. A minimal such effective field theory, with this sole Z{sub 2} breaking, can generate the Z{sub 2} breaking in the Higgs sector necessary for the Twin Higgs mechanism. The theory has constrained and correlated signals in Higgs decays, direct Dark Matter Detection and Dark Radiation, all within reach of foreseen experiments, over a region of parameter space where the fine-tuning for the electroweak scale is 10-50%. For dark matter, both mirror neutrons and a variety of self-interacting mirror atoms are considered. Neutrino mass signals and the effects of a possible additional Z{sub 2} breaking from the vacuum expectation values of B−L breaking fields are also discussed.

  2. Global Analysis of Minimal Surfaces

    CERN Document Server

    Dierkes, Ulrich; Tromba, Anthony J

    2010-01-01

    Many properties of minimal surfaces are of a global nature, and this is already true for the results treated in the first two volumes of the treatise. Part I of the present book can be viewed as an extension of these results. For instance, the first two chapters deal with existence, regularity and uniqueness theorems for minimal surfaces with partially free boundaries. Here one of the main features is the possibility of 'edge-crawling' along free parts of the boundary. The third chapter deals with a priori estimates for minimal surfaces in higher dimensions and for minimizers of singular integ

  3. Minimal Surfaces for Hitchin Representations

    DEFF Research Database (Denmark)

    Li, Qiongling; Dai, Song

    2018-01-01

    . In this paper, we investigate the properties of immersed minimal surfaces inside symmetric space associated to a subloci of Hitchin component: $q_n$ and $q_{n-1}$ case. First, we show that the pullback metric of the minimal surface dominates a constant multiple of the hyperbolic metric in the same conformal...... class and has a strong rigidity property. Secondly, we show that the immersed minimal surface is never tangential to any flat inside the symmetric space. As a direct corollary, the pullback metric of the minimal surface is always strictly negatively curved. In the end, we find a fully decoupled system...

  4. Guidelines for mixed waste minimization

    International Nuclear Information System (INIS)

    Owens, C.

    1992-02-01

    Currently, there is no commercial mixed waste disposal available in the United States. Storage and treatment for commercial mixed waste is limited. Host States and compacts region officials are encouraging their mixed waste generators to minimize their mixed wastes because of management limitations. This document provides a guide to mixed waste minimization

  5. Minimal changes in health status questionnaires: distinction between minimally detectable change and minimally important change

    Directory of Open Access Journals (Sweden)

    Knol Dirk L

    2006-08-01

    Full Text Available Abstract Changes in scores on health status questionnaires are difficult to interpret. Several methods to determine minimally important changes (MICs have been proposed which can broadly be divided in distribution-based and anchor-based methods. Comparisons of these methods have led to insight into essential differences between these approaches. Some authors have tried to come to a uniform measure for the MIC, such as 0.5 standard deviation and the value of one standard error of measurement (SEM. Others have emphasized the diversity of MIC values, depending on the type of anchor, the definition of minimal importance on the anchor, and characteristics of the disease under study. A closer look makes clear that some distribution-based methods have been merely focused on minimally detectable changes. For assessing minimally important changes, anchor-based methods are preferred, as they include a definition of what is minimally important. Acknowledging the distinction between minimally detectable and minimally important changes is useful, not only to avoid confusion among MIC methods, but also to gain information on two important benchmarks on the scale of a health status measurement instrument. Appreciating the distinction, it becomes possible to judge whether the minimally detectable change of a measurement instrument is sufficiently small to detect minimally important changes.

  6. Waste minimization handbook, Volume 1

    International Nuclear Information System (INIS)

    Boing, L.E.; Coffey, M.J.

    1995-12-01

    This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility's life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996

  7. Waste minimization handbook, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Boing, L.E.; Coffey, M.J.

    1995-12-01

    This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility`s life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996.

  8. Minimal Webs in Riemannian Manifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen

    2008-01-01

    For a given combinatorial graph $G$ a {\\it geometrization} $(G, g)$ of the graph is obtained by considering each edge of the graph as a $1-$dimensional manifold with an associated metric $g$. In this paper we are concerned with {\\it minimal isometric immersions} of geometrized graphs $(G, g......)$ into Riemannian manifolds $(N^{n}, h)$. Such immersions we call {\\em{minimal webs}}. They admit a natural 'geometric' extension of the intrinsic combinatorial discrete Laplacian. The geometric Laplacian on minimal webs enjoys standard properties such as the maximum principle and the divergence theorems, which...... are of instrumental importance for the applications. We apply these properties to show that minimal webs in ambient Riemannian spaces share several analytic and geometric properties with their smooth (minimal submanifold) counterparts in such spaces. In particular we use appropriate versions of the divergence...

  9. Minimal Poems Written in 1979 Minimal Poems Written in 1979

    Directory of Open Access Journals (Sweden)

    Sandra Sirangelo Maggio

    2008-04-01

    Full Text Available The reading of M. van der Slice's Minimal Poems Written in 1979 (the work, actually, has no title reminded me of a book I have seen a long time ago. called Truth, which had not even a single word printed inside. In either case we have a sample of how often excentricities can prove efficient means of artistic creativity, in this new literary trend known as Minimalism. The reading of M. van der Slice's Minimal Poems Written in 1979 (the work, actually, has no title reminded me of a book I have seen a long time ago. called Truth, which had not even a single word printed inside. In either case we have a sample of how often excentricities can prove efficient means of artistic creativity, in this new literary trend known as Minimalism.

  10. Minimal Flavour Violation and Beyond

    CERN Document Server

    Isidori, Gino

    2012-01-01

    We review the formulation of the Minimal Flavour Violation (MFV) hypothesis in the quark sector, as well as some "variations on a theme" based on smaller flavour symmetry groups and/or less minimal breaking terms. We also review how these hypotheses can be tested in B decays and by means of other flavour-physics observables. The phenomenological consequences of MFV are discussed both in general terms, employing a general effective theory approach, and in the specific context of the Minimal Supersymmetric extension of the SM.

  11. Minimizing waste in environmental restoration

    International Nuclear Information System (INIS)

    Thuot, J.R.; Moos, L.

    1996-01-01

    Environmental restoration, decontamination and decommissioning, and facility dismantlement projects are not typically known for their waste minimization and pollution prevention efforts. Typical projects are driven by schedules and milestones with little attention given to cost or waste minimization. Conventional wisdom in these projects is that the waste already exists and cannot be reduced or minimized; however, there are significant areas where waste and cost can be reduced by careful planning and execution. Waste reduction can occur in three ways: beneficial reuse or recycling, segregation of waste types, and reducing generation of secondary waste

  12. Minimizing waste in environmental restoration

    International Nuclear Information System (INIS)

    Moos, L.; Thuot, J.R.

    1996-01-01

    Environmental restoration, decontamination and decommissioning and facility dismantelment projects are not typically known for their waste minimization and pollution prevention efforts. Typical projects are driven by schedules and milestones with little attention given to cost or waste minimization. Conventional wisdom in these projects is that the waste already exists and cannot be reduced or minimized. In fact, however, there are three significant areas where waste and cost can be reduced. Waste reduction can occur in three ways: beneficial reuse or recycling; segregation of waste types; and reducing generation of secondary waste. This paper will discuss several examples of reuse, recycle, segregation, and secondary waste reduction at ANL restoration programs

  13. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  14. Sludge minimization technologies - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Oedegaard, Hallvard

    2003-07-01

    The management of wastewater sludge from wastewater treatment plants represents one of the major challenges in wastewater treatment today. The cost of the sludge treatment amounts to more that the cost of the liquid in many cases. Therefore the focus on and interest in sludge minimization is steadily increasing. In the paper an overview is given for sludge minimization (sludge mass reduction) options. It is demonstrated that sludge minimization may be a result of reduced production of sludge and/or disintegration processes that may take place both in the wastewater treatment stage and in the sludge stage. Various sludge disintegration technologies for sludge minimization are discussed, including mechanical methods (focusing on stirred ball-mill, high-pressure homogenizer, ultrasonic disintegrator), chemical methods (focusing on the use of ozone), physical methods (focusing on thermal and thermal/chemical hydrolysis) and biological methods (focusing on enzymatic processes). (author)

  15. Wilson loops in minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS/CFT correspondence suggests that the Wilson loop of the large N gauge theory with N = 4 supersymmetry in 4 dimensions is described by a minimal surface in AdS 5 x S 5 . The authors examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which the authors call BPS loops, whose expectation values are free from ultra-violet divergence. They formulate the loop equation for such loops. To the extent that they have checked, the minimal surface in AdS 5 x S 5 gives a solution of the equation. The authors also discuss the zig-zag symmetry of the loop operator. In the N = 4 gauge theory, they expect the zig-zag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. They will show how this is realized for the minimal surface

  16. Classical strings and minimal surfaces

    International Nuclear Information System (INIS)

    Urbantke, H.

    1986-01-01

    Real Lorentzian forms of some complex or complexified Euclidean minimal surfaces are obtained as an application of H.A. Schwarz' solution to the initial value problem or a search for surfaces admitting a group of Poincare transformations. (Author)

  17. Minimal Gromov-Witten rings

    International Nuclear Information System (INIS)

    Przyjalkowski, V V

    2008-01-01

    We construct an abstract theory of Gromov-Witten invariants of genus 0 for quantum minimal Fano varieties (a minimal class of varieties which is natural from the quantum cohomological viewpoint). Namely, we consider the minimal Gromov-Witten ring: a commutative algebra whose generators and relations are of the form used in the Gromov-Witten theory of Fano varieties (of unspecified dimension). The Gromov-Witten theory of any quantum minimal variety is a homomorphism from this ring to C. We prove an abstract reconstruction theorem which says that this ring is isomorphic to the free commutative ring generated by 'prime two-pointed invariants'. We also find solutions of the differential equation of type DN for a Fano variety of dimension N in terms of the generating series of one-pointed Gromov-Witten invariants

  18. Wilson loops and minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS-CFT correspondence suggests that the Wilson loop of the large N gauge theory with N=4 supersymmetry in four dimensions is described by a minimal surface in AdS 5 xS 5 . We examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which we call BPS loops, whose expectation values are free from ultraviolet divergence. We formulate the loop equation for such loops. To the extent that we have checked, the minimal surface in AdS 5 xS 5 gives a solution of the equation. We also discuss the zigzag symmetry of the loop operator. In the N=4 gauge theory, we expect the zigzag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. We will show how this is realized for the minimal surface. (c) 1999 The American Physical Society

  19. Minimal string theory is logarithmic

    International Nuclear Information System (INIS)

    Ishimoto, Yukitaka; Yamaguchi, Shun-ichi

    2005-01-01

    We study the simplest examples of minimal string theory whose worldsheet description is the unitary (p,q) minimal model coupled to two-dimensional gravity ( Liouville field theory). In the Liouville sector, we show that four-point correlation functions of 'tachyons' exhibit logarithmic singularities, and that the theory turns out to be logarithmic. The relation with Zamolodchikov's logarithmic degenerate fields is also discussed. Our result holds for generic values of (p,q)

  20. Annual Waste Minimization Summary Report

    International Nuclear Information System (INIS)

    Haworth, D.M.

    2011-01-01

    This report summarizes the waste minimization efforts undertaken by National Security TechnoIogies, LLC, for the U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), during calendar year 2010. The NNSA/NSO Pollution Prevention Program establishes a process to reduce the volume and toxicity of waste generated by NNSA/NSO activities and ensures that proposed methods of treatment, storage, and/or disposal of waste minimize potential threats to human health and the environment.

  1. Effects of gamma radiation in cauliflower (Brassica spp) minimally processed

    International Nuclear Information System (INIS)

    Nunes, Thaise C.F.; Rogovschi, Vladimir D.; Thomaz, Fernanda S.; Trindade, Reginaldo A.; Villavicencio, Anna L.C.H.; Alencar, Severino M.

    2007-01-01

    Consumers demand for health interests and the latest diet trends. The consumption of vegetables worldwide has increased every year over the past decade, consequently, less extreme treatments or additives are being required. Minimally processed foods have fresh-like characteristics and satisfy the new consumer demand. Food irradiation is an exposure process of the product to controlled sources of gamma radiation with the intention to destroy pathogens and to extend the shelf life. Minimally processed cauliflower (Brassica oleraceae) exposed to low dose of gamma radiation does not show any change in sensory attributes. The aim of this study was to analyze the effects of the low doses of gamma radiation on sensorial aspects like appearance, texture and flavor of minimally processed cauliflower. (author)

  2. Maintaining occupational dose ALARA through work management

    International Nuclear Information System (INIS)

    Khan, A. H.

    1999-01-01

    Canadian philosophy in keeping occupational dose ALARA has been to train staff in radiation safety so that they can be fully responsible for participating in minimizing the risks associated with the hazardous work. Senior managers actively promote high standards of performance in dose reduction techniques as a means for integrating ALARA into the operation and maintenance of the station by all personnel. Minimizing radiation dose is accomplished by applying cost effective work management techniques such as Job Safety Analysis, pre-job briefings and establishing and achieving radiation dose goals. Radiation dose goals are used as a management tool for involving all work groups in reducing doses as well as providing a means of assessing the effectiveness of dose reduction actions. ALARA, along with conventional safety, is used as a lever to raise the standard of quality of work and to overall build a safety culture. (author). 4 figs

  3. CT dose reduction in children

    International Nuclear Information System (INIS)

    Vock, Peter

    2005-01-01

    World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposure. (orig.)

  4. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  5. Minimal but non-minimal inflation and electroweak symmetry breaking

    Energy Technology Data Exchange (ETDEWEB)

    Marzola, Luca [National Institute of Chemical Physics and Biophysics,Rävala 10, 10143 Tallinn (Estonia); Institute of Physics, University of Tartu,Ravila 14c, 50411 Tartu (Estonia); Racioppi, Antonio [National Institute of Chemical Physics and Biophysics,Rävala 10, 10143 Tallinn (Estonia)

    2016-10-07

    We consider the most minimal scale invariant extension of the standard model that allows for successful radiative electroweak symmetry breaking and inflation. The framework involves an extra scalar singlet, that plays the rôle of the inflaton, and is compatibile with current experimental bounds owing to the non-minimal coupling of the latter to gravity. This inflationary scenario predicts a very low tensor-to-scalar ratio r≈10{sup −3}, typical of Higgs-inflation models, but in contrast yields a scalar spectral index n{sub s}≃0.97 which departs from the Starobinsky limit. We briefly discuss the collider phenomenology of the framework.

  6. Minimal modification to tribimaximal mixing

    International Nuclear Information System (INIS)

    He Xiaogang; Zee, A.

    2011-01-01

    We explore some ways of minimally modifying the neutrino mixing matrix from tribimaximal, characterized by introducing at most one mixing angle and a CP violating phase thus extending our earlier work. One minimal modification, motivated to some extent by group theoretic considerations, is a simple case with the elements V α2 of the second column in the mixing matrix equal to 1/√(3). Modifications by keeping one of the columns or one of the rows unchanged from tribimaximal mixing all belong to the class of minimal modification. Some of the cases have interesting experimentally testable consequences. In particular, the T2K and MINOS collaborations have recently reported indications of a nonzero θ 13 . For the cases we consider, the new data sharply constrain the CP violating phase angle δ, with δ close to 0 (in some cases) and π disfavored.

  7. Topological gravity with minimal matter

    International Nuclear Information System (INIS)

    Li Keke

    1991-01-01

    Topological minimal matter, obtained by twisting the minimal N = 2 supeconformal field theory, is coupled to two-dimensional topological gravity. The free field formulation of the coupled system allows explicit representations of BRST charge, physical operators and their correlation functions. The contact terms of the physical operators may be evaluated by extending the argument used in a recent solution of topological gravity without matter. The consistency of the contact terms in correlation functions implies recursion relations which coincide with the Virasoro constraints derived from the multi-matrix models. Topological gravity with minimal matter thus provides the field theoretic description for the multi-matrix models of two-dimensional quantum gravity. (orig.)

  8. Minimal Marking: A Success Story

    Directory of Open Access Journals (Sweden)

    Anne McNeilly

    2014-11-01

    Full Text Available The minimal-marking project conducted in Ryerson’s School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The “minimal-marking” concept (Haswell, 1983, which requires dramatically more student engagement, resulted in more successful learning outcomes for surface-level knowledge acquisition than the more traditional approach of “teacher-corrects-all.” Results suggest it would be effective, not just for grammar, punctuation, and word usage, the objective here, but for any material that requires rote-memory learning, such as the Associated Press or Canadian Press style rules used by news publications across North America.

  9. Non-minimal inflation revisited

    International Nuclear Information System (INIS)

    Nozari, Kourosh; Shafizadeh, Somayeh

    2010-01-01

    We reconsider an inflationary model that inflaton field is non-minimally coupled to gravity. We study the parameter space of the model up to the second (and in some cases third) order of the slow-roll parameters. We calculate inflation parameters in both Jordan and Einstein frames, and the results are compared in these two frames and also with observations. Using the recent observational data from combined WMAP5+SDSS+SNIa datasets, we study constraints imposed on our model parameters, especially the non-minimal coupling ξ.

  10. Minimal Flavor Constraints for Technicolor

    DEFF Research Database (Denmark)

    Sakuma, Hidenori; Sannino, Francesco

    2010-01-01

    We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self-coupling and mas......We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self...

  11. Harm minimization among teenage drinkers

    DEFF Research Database (Denmark)

    Jørgensen, Morten Hulvej; Curtis, Tine; Christensen, Pia Haudrup

    2007-01-01

    AIM: To examine strategies of harm minimization employed by teenage drinkers. DESIGN, SETTING AND PARTICIPANTS: Two periods of ethnographic fieldwork were conducted in a rural Danish community of approximately 2000 inhabitants. The fieldwork included 50 days of participant observation among 13....... In regulating the social context of drinking they relied on their personal experiences more than on formalized knowledge about alcohol and harm, which they had learned from prevention campaigns and educational programmes. CONCLUSIONS: In this study we found that teenagers may help each other to minimize alcohol...

  12. Isoperimetric inequalities for minimal graphs

    International Nuclear Information System (INIS)

    Pacelli Bessa, G.; Montenegro, J.F.

    2007-09-01

    Based on Markvorsen and Palmer's work on mean time exit and isoperimetric inequalities we establish slightly better isoperimetric inequalities and mean time exit estimates for minimal graphs in N x R. We also prove isoperimetric inequalities for submanifolds of Hadamard spaces with tamed second fundamental form. (author)

  13. A Defense of Semantic Minimalism

    Science.gov (United States)

    Kim, Su

    2012-01-01

    Semantic Minimalism is a position about the semantic content of declarative sentences, i.e., the content that is determined entirely by syntax. It is defined by the following two points: "Point 1": The semantic content is a complete/truth-conditional proposition. "Point 2": The semantic content is useful to a theory of…

  14. Torsional Rigidity of Minimal Submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, Vicente

    2006-01-01

    We prove explicit upper bounds for the torsional rigidity of extrinsic domains of minimal submanifolds $P^m$ in ambient Riemannian manifolds $N^n$ with a pole $p$. The upper bounds are given in terms of the torsional rigidities of corresponding Schwarz symmetrizations of the domains in warped...

  15. The debate on minimal deterrence

    International Nuclear Information System (INIS)

    Arbatov, A.; Karp, R.C.; Toth, T.

    1993-01-01

    Revitalization of debates on minimal nuclear deterrence at the present time is induced by the end of the Cold War and a number of unilateral and bilateral actions by the great powers to curtail nuclear arms race and reduce nuclear weapons arsenals

  16. LLNL Waste Minimization Program Plan

    International Nuclear Information System (INIS)

    1990-01-01

    This document is the February 14, 1990 version of the LLNL Waste Minimization Program Plan (WMPP). The Waste Minimization Policy field has undergone continuous changes since its formal inception in the 1984 HSWA legislation. The first LLNL WMPP, Revision A, is dated March 1985. A series of informal revision were made on approximately a semi-annual basis. This Revision 2 is the third formal issuance of the WMPP document. EPA has issued a proposed new policy statement on source reduction and recycling. This policy reflects a preventative strategy to reduce or eliminate the generation of environmentally-harmful pollutants which may be released to the air, land surface, water, or ground water. In accordance with this new policy new guidance to hazardous waste generators on the elements of a Waste Minimization Program was issued. In response to these policies, DOE has revised and issued implementation guidance for DOE Order 5400.1, Waste Minimization Plan and Waste Reduction reporting of DOE Hazardous, Radioactive, and Radioactive Mixed Wastes, final draft January 1990. This WMPP is formatted to meet the current DOE guidance outlines. The current WMPP will be revised to reflect all of these proposed changes when guidelines are established. Updates, changes and revisions to the overall LLNL WMPP will be made as appropriate to reflect ever-changing regulatory requirements. 3 figs., 4 tabs

  17. Minimizing TLD-DRD differences

    International Nuclear Information System (INIS)

    Riley, D.L.; McCoy, R.A.; Connell, W.D.

    1987-01-01

    When substantial differences exist in exposures recorded by TLD's and DRD's, it is often necessary to perform an exposure investigation to reconcile the difference. In working with several operating plants, the authors have observed a number of causes for these differences. This paper outlines these observations and discusses procedures that can be used to minimize them

  18. Acquiring minimally invasive surgical skills

    NARCIS (Netherlands)

    Hiemstra, Ellen

    2012-01-01

    Many topics in surgical skills education have been implemented without a solid scientific basis. For that reason we have tried to find this scientific basis. We have focused on training and evaluation of minimally invasive surgical skills in a training setting and in practice in the operating room.

  19. Hazardous waste minimization tracking system

    International Nuclear Information System (INIS)

    Railan, R.

    1994-01-01

    Under RCRA section 3002 9(b) and 3005f(h), hazardous waste generators and owners/operators of treatment, storage, and disposal facilities (TSDFs) are required to certify that they have a program in place to reduce the volume or quantity and toxicity of hazardous waste to the degree determined to be economically practicable. In many cases, there are environmental, as well as, economic benefits, for agencies that pursue pollution prevention options. Several state governments have already enacted waste minimization legislation (e.g., Massachusetts Toxic Use Reduction Act of 1989, and Oregon Toxic Use Reduction Act and Hazardous Waste Reduction Act, July 2, 1989). About twenty six other states have established legislation that will mandate some type of waste minimization program and/or facility planning. The need to address the HAZMIN (Hazardous Waste Minimization) Program at government agencies and private industries has prompted us to identify the importance of managing The HAZMIN Program, and tracking various aspects of the program, as well as the progress made in this area. The open-quotes WASTEclose quotes is a tracking system, which can be used and modified in maintaining the information related to Hazardous Waste Minimization Program, in a manageable fashion. This program maintains, modifies, and retrieves information related to hazardous waste minimization and recycling, and provides automated report generating capabilities. It has a built-in menu, which can be printed either in part or in full. There are instructions on preparing The Annual Waste Report, and The Annual Recycling Report. The program is very user friendly. This program is available in 3.5 inch or 5 1/4 inch floppy disks. A computer with 640K memory is required

  20. Minimizing exposure in nuclear medicine through optimum use of shielding devices

    International Nuclear Information System (INIS)

    Rutherford, B.L.; King, S.H.; Erdman, M.C.; Miller, K.L.

    1991-01-01

    Exposure to radiation from nuclear medicine nuclides can be minimized through the use of various shielding devices. This paper reviews the dose reductions achieved through use of various syringe shields, lead aprons, leaded gloves, and several types of eyeglass lenses for 67 Ga, 99m Tc, 131 I and 201 Tl. The authors have found that combination of devices can best provide for minimizing doses

  1. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  2. Minimalism and the Pragmatic Frame

    Directory of Open Access Journals (Sweden)

    Ana Falcato

    2016-02-01

    Full Text Available In the debate between literalism and contextualism in semantics, Kent Bach’s project is often taken to stand on the latter side of the divide. In this paper I argue this is a misleading assumption and justify it by contrasting Bach’s assessment of the theoretical eliminability of minimal propositions arguably expressed by well-formed sentences with standard minimalist views, and by further contrasting his account of the division of interpretative processes ascribable to the semantics and pragmatics of a language with a parallel analysis carried out by the most radical opponent to semantic minimalism, i.e., by occasionalism. If my analysis proves right, the sum of its conclusions amounts to a refusal of Bach’s main dichotomies.

  3. Principle of minimal work fluctuations.

    Science.gov (United States)

    Xiao, Gaoyang; Gong, Jiangbin

    2015-08-01

    Understanding and manipulating work fluctuations in microscale and nanoscale systems are of both fundamental and practical interest. For example, in considering the Jarzynski equality 〈e-βW〉=e-βΔF, a change in the fluctuations of e-βW may impact how rapidly the statistical average of e-βW converges towards the theoretical value e-βΔF, where W is the work, β is the inverse temperature, and ΔF is the free energy difference between two equilibrium states. Motivated by our previous study aiming at the suppression of work fluctuations, here we obtain a principle of minimal work fluctuations. In brief, adiabatic processes as treated in quantum and classical adiabatic theorems yield the minimal fluctuations in e-βW. In the quantum domain, if a system initially prepared at thermal equilibrium is subjected to a work protocol but isolated from a bath during the time evolution, then a quantum adiabatic process without energy level crossing (or an assisted adiabatic process reaching the same final states as in a conventional adiabatic process) yields the minimal fluctuations in e-βW, where W is the quantum work defined by two energy measurements at the beginning and at the end of the process. In the classical domain where the classical work protocol is realizable by an adiabatic process, then the classical adiabatic process also yields the minimal fluctuations in e-βW. Numerical experiments based on a Landau-Zener process confirm our theory in the quantum domain, and our theory in the classical domain explains our previous numerical findings regarding the suppression of classical work fluctuations [G. Y. Xiao and J. B. Gong, Phys. Rev. E 90, 052132 (2014)].

  4. Optimizing Processes to Minimize Risk

    Science.gov (United States)

    Loyd, David

    2017-01-01

    NASA, like the other hazardous industries, has suffered very catastrophic losses. Human error will likely never be completely eliminated as a factor in our failures. When you can't eliminate risk, focus on mitigating the worst consequences and recovering operations. Bolstering processes to emphasize the role of integration and problem solving is key to success. Building an effective Safety Culture bolsters skill-based performance that minimizes risk and encourages successful engagement.

  5. Minimal Length, Measurability and Gravity

    Directory of Open Access Journals (Sweden)

    Alexander Shalyt-Margolin

    2016-03-01

    Full Text Available The present work is a continuation of the previous papers written by the author on the subject. In terms of the measurability (or measurable quantities notion introduced in a minimal length theory, first the consideration is given to a quantum theory in the momentum representation. The same terms are used to consider the Markov gravity model that here illustrates the general approach to studies of gravity in terms of measurable quantities.

  6. [Minimally invasive coronary artery surgery].

    Science.gov (United States)

    Zalaquett, R; Howard, M; Irarrázaval, M J; Morán, S; Maturana, G; Becker, P; Medel, J; Sacco, C; Lema, G; Canessa, R; Cruz, F

    1999-01-01

    There is a growing interest to perform a left internal mammary artery (LIMA) graft to the left anterior descending coronary artery (LAD) on a beating heart through a minimally invasive access to the chest cavity. To report the experience with minimally invasive coronary artery surgery. Analysis of 11 patients aged 48 to 79 years old with single vessel disease that, between 1996 and 1997, had a LIMA graft to the LAD performed through a minimally invasive left anterior mediastinotomy, without cardiopulmonary bypass. A 6 to 10 cm left parasternal incision was done. The LIMA to the LAD anastomosis was done after pharmacological heart rate and blood pressure control and a period of ischemic pre conditioning. Graft patency was confirmed intraoperatively by standard Doppler techniques. Patients were followed for a mean of 11.6 months (7-15 months). All patients were extubated in the operating room and transferred out of the intensive care unit on the next morning. Seven patients were discharged on the third postoperative day. Duplex scanning confirmed graft patency in all patients before discharge; in two patients, it was confirmed additionally by arteriography. There was no hospital mortality, no perioperative myocardial infarction and no bleeding problems. After follow up, ten patients were free of angina, in functional class I and pleased with the surgical and cosmetic results. One patient developed atypical angina on the seventh postoperative month and a selective arteriography confirmed stenosis of the anastomosis. A successful angioplasty of the original LAD lesion was carried out. A minimally invasive left anterior mediastinotomy is a good surgical access to perform a successful LIMA to LAD graft without cardiopulmonary bypass, allowing a shorter hospital stay and earlier postoperative recovery. However, a larger experience and a longer follow up is required to define its role in the treatment of coronary artery disease.

  7. Minimal massive 3D gravity

    International Nuclear Information System (INIS)

    Bergshoeff, Eric; Merbis, Wout; Hohm, Olaf; Routh, Alasdair J; Townsend, Paul K

    2014-01-01

    We present an alternative to topologically massive gravity (TMG) with the same ‘minimal’ bulk properties; i.e. a single local degree of freedom that is realized as a massive graviton in linearization about an anti-de Sitter (AdS) vacuum. However, in contrast to TMG, the new ‘minimal massive gravity’ has both a positive energy graviton and positive central charges for the asymptotic AdS-boundary conformal algebra. (paper)

  8. Construction schedules slack time minimizing

    Science.gov (United States)

    Krzemiński, Michał

    2017-07-01

    The article presents two copyright models for minimizing downtime working brigades. Models have been developed for construction schedules performed using the method of work uniform. Application of flow shop models is possible and useful for the implementation of large objects, which can be divided into plots. The article also presents a condition describing gives which model should be used, as well as a brief example of optimization schedule. The optimization results confirm the legitimacy of the work on the newly-developed models.

  9. Acquiring minimally invasive surgical skills

    OpenAIRE

    Hiemstra, Ellen

    2012-01-01

    Many topics in surgical skills education have been implemented without a solid scientific basis. For that reason we have tried to find this scientific basis. We have focused on training and evaluation of minimally invasive surgical skills in a training setting and in practice in the operating room. This thesis has led to an enlarged insight in the organization of surgical skills training during residency training of surgical medical specialists.

  10. Minimal families of curves on surfaces

    KAUST Repository

    Lubbes, Niels

    2014-01-01

    A minimal family of curves on an embedded surface is defined as a 1-dimensional family of rational curves of minimal degree, which cover the surface. We classify such minimal families using constructive methods. This allows us to compute the minimal

  11. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  12. Minimal families of curves on surfaces

    KAUST Repository

    Lubbes, Niels

    2014-11-01

    A minimal family of curves on an embedded surface is defined as a 1-dimensional family of rational curves of minimal degree, which cover the surface. We classify such minimal families using constructive methods. This allows us to compute the minimal families of a given surface.The classification of minimal families of curves can be reduced to the classification of minimal families which cover weak Del Pezzo surfaces. We classify the minimal families of weak Del Pezzo surfaces and present a table with the number of minimal families of each weak Del Pezzo surface up to Weyl equivalence.As an application of this classification we generalize some results of Schicho. We classify algebraic surfaces that carry a family of conics. We determine the minimal lexicographic degree for the parametrization of a surface that carries at least 2 minimal families. © 2014 Elsevier B.V.

  13. LLNL Waste Minimization Program Plan

    International Nuclear Information System (INIS)

    1990-05-01

    This document is the February 14, 1990 version of the LLNL Waste Minimization Program Plan (WMPP). Now legislation at the federal level is being introduced. Passage will result in new EPA regulations and also DOE orders. At the state level the Hazardous Waste Reduction and Management Review Act of 1989 was signed by the Governor. DHS is currently promulgating regulations to implement the new law. EPA has issued a proposed new policy statement on source reduction and recycling. This policy reflects a preventative strategy to reduce or eliminate the generation of environmentally-harmful pollutants which may be released to the air, land surface, water, or ground water. In accordance with this policy new guidance to hazardous waste generators on the elements of a Waste Minimization Program was issued. This WMPP is formatted to meet the current DOE guidance outlines. The current WMPP will be revised to reflect all of these proposed changes when guidelines are established. Updates, changes and revisions to the overall LLNL WMPP will be made as appropriate to reflect ever-changing regulatory requirements

  14. Symmetry breaking for drag minimization

    Science.gov (United States)

    Roper, Marcus; Squires, Todd M.; Brenner, Michael P.

    2005-11-01

    For locomotion at high Reynolds numbers drag minimization favors fore-aft asymmetric slender shapes with blunt noses and sharp trailing edges. On the other hand, in an inertialess fluid the drag experienced by a body is independent of whether it travels forward or backward through the fluid, so there is no advantage to having a single preferred swimming direction. In fact numerically determined minimum drag shapes are known to exhibit almost no fore-aft asymmetry even at moderate Re. We show that asymmetry persists, albeit extremely weakly, down to vanishingly small Re, scaling asymptotically as Re^3. The need to minimize drag to maximize speed for a given propulsive capacity gives one possible mechanism for the increasing asymmetry in the body plans seen in nature, as organisms increase in size and swimming speed from bacteria like E-Coli up to pursuit predator fish such as tuna. If it is the dominant mechanism, then this signature scaling will be observed in the shapes of motile micro-organisms.

  15. Laparoscopic colonic resection in inflammatory bowel disease: minimal surgery, minimal access and minimal hospital stay.

    LENUS (Irish Health Repository)

    Boyle, E

    2008-11-01

    Laparoscopic surgery for inflammatory bowel disease (IBD) is technically demanding but can offer improved short-term outcomes. The introduction of minimally invasive surgery (MIS) as the default operative approach for IBD, however, may have inherent learning curve-associated disadvantages. We hypothesise that the establishment of MIS as the standard operative approach does not increase patient morbidity as assessed in the initial period of its introduction into a specialised unit, and that it confers earlier postoperative gastrointestinal recovery and reduced hospitalisation compared with conventional open resection.

  16. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    also the high dose volume. The optimization on dose points and geometry provides the most uniform dose distribution. The dose non-uniformity ratio can be minimized by selecting the isodose line of the midpoints between the catheters in the whole volume for the dose prescription, but the dose coverage may not be adequate. For a clinically acceptable plan, a compromise should be made between dose non-uniformity and coverage. (author)

  17. Varietal improvement of irrigated rice under minimal water conditions

    International Nuclear Information System (INIS)

    Abdul Rahim Harun; Marziah Mahmood; Sobri Hussein

    2010-01-01

    Varietal improvement of irrigated rice under minimal water condition is a research project under Program Research of Sustainable Production of High Yielding Irrigated Rice under Minimal Water Input (IRPA- 01-01-03-0000/ PR0068/ 0504). Several agencies were involved in this project such as Malaysian Nuclear Agency (MNA), Malaysian Agricultural Research and Development Institute (MARDI), Universiti Putra Malaysia (UPM) and Ministry of Agriculture (MOA). The project started in early 2004 with approved IRPA fund of RM 275,000.00 for 3 years. The main objective of the project is to generate superior genotypes for minimal water requirement through induced mutation techniques. A cultivated rice Oryza sativa cv MR219 treated with gamma radiation at 300 and 400 Gray were used in the experiment. Two hundred gm M2 seeds from each dose were screened under minimal water stress in greenhouse at Mardi Seberang Perai. Five hundred panicles with good filled grains were selected for paddy field screening with simulate precise water stress regime. Thirty eight potential lines with required adaptive traits were selected in M3. After several series of selection, 12 promising mutant line were observed tolerance to minimal water stress where two promising mutant lines designated as MR219-4 and MR219-9 were selected for further testing under several stress environments. (author)

  18. Minimizing radiation exposure during percutaneous nephrolithotomy.

    Science.gov (United States)

    Chen, T T; Preminger, G M; Lipkin, M E

    2015-12-01

    Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.

  19. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  20. Minimization over randomly selected lines

    Directory of Open Access Journals (Sweden)

    Ismet Sahin

    2013-07-01

    Full Text Available This paper presents a population-based evolutionary optimization method for minimizing a given cost function. The mutation operator of this method selects randomly oriented lines in the cost function domain, constructs quadratic functions interpolating the cost function at three different points over each line, and uses extrema of the quadratics as mutated points. The crossover operator modifies each mutated point based on components of two points in population, instead of one point as is usually performed in other evolutionary algorithms. The stopping criterion of this method depends on the number of almost degenerate quadratics. We demonstrate that the proposed method with these mutation and crossover operations achieves faster and more robust convergence than the well-known Differential Evolution and Particle Swarm algorithms.

  1. Strategies to Minimize Antibiotic Resistance

    Directory of Open Access Journals (Sweden)

    Sang Hee Lee

    2013-09-01

    Full Text Available Antibiotic resistance can be reduced by using antibiotics prudently based on guidelines of antimicrobial stewardship programs (ASPs and various data such as pharmacokinetic (PK and pharmacodynamic (PD properties of antibiotics, diagnostic testing, antimicrobial susceptibility testing (AST, clinical response, and effects on the microbiota, as well as by new antibiotic developments. The controlled use of antibiotics in food animals is another cornerstone among efforts to reduce antibiotic resistance. All major resistance-control strategies recommend education for patients, children (e.g., through schools and day care, the public, and relevant healthcare professionals (e.g., primary-care physicians, pharmacists, and medical students regarding unique features of bacterial infections and antibiotics, prudent antibiotic prescribing as a positive construct, and personal hygiene (e.g., handwashing. The problem of antibiotic resistance can be minimized only by concerted efforts of all members of society for ensuring the continued efficiency of antibiotics.

  2. A minimally invasive smile enhancement.

    Science.gov (United States)

    Peck, Fred H

    2014-01-01

    Minimally invasive dentistry refers to a wide variety of dental treatments. On the restorative aspect of dental procedures, direct resin bonding can be a very conservative treatment option for the patient. When tooth structure does not need to be removed, the patient benefits. Proper treatment planning is essential to determine how conservative the restorative treatment will be. This article describes the diagnosis, treatment options, and procedural techniques in the restoration of 4 maxillary anterior teeth with direct composite resin. The procedural steps are reviewed with regard to placing the composite and the variety of colors needed to ensure a natural result. Finishing and polishing of the composite are critical to ending with a natural looking dentition that the patient will be pleased with for many years.

  3. Waste minimization in analytical methods

    International Nuclear Information System (INIS)

    Green, D.W.; Smith, L.L.; Crain, J.S.; Boparai, A.S.; Kiely, J.T.; Yaeger, J.S. Schilling, J.B.

    1995-01-01

    The US Department of Energy (DOE) will require a large number of waste characterizations over a multi-year period to accomplish the Department's goals in environmental restoration and waste management. Estimates vary, but two million analyses annually are expected. The waste generated by the analytical procedures used for characterizations is a significant source of new DOE waste. Success in reducing the volume of secondary waste and the costs of handling this waste would significantly decrease the overall cost of this DOE program. Selection of appropriate analytical methods depends on the intended use of the resultant data. It is not always necessary to use a high-powered analytical method, typically at higher cost, to obtain data needed to make decisions about waste management. Indeed, for samples taken from some heterogeneous systems, the meaning of high accuracy becomes clouded if the data generated are intended to measure a property of this system. Among the factors to be considered in selecting the analytical method are the lower limit of detection, accuracy, turnaround time, cost, reproducibility (precision), interferences, and simplicity. Occasionally, there must be tradeoffs among these factors to achieve the multiple goals of a characterization program. The purpose of the work described here is to add waste minimization to the list of characteristics to be considered. In this paper the authors present results of modifying analytical methods for waste characterization to reduce both the cost of analysis and volume of secondary wastes. Although tradeoffs may be required to minimize waste while still generating data of acceptable quality for the decision-making process, they have data demonstrating that wastes can be reduced in some cases without sacrificing accuracy or precision

  4. Gonadal dose reduction in lumbar spine radiography

    International Nuclear Information System (INIS)

    Moilanen, A.; Kokko, M.L.; Pitkaenen, M.

    1983-01-01

    Different ways to minimize the gonadal dose in lumbar spine radiography have been studied. Two hundred and fifty lumbar spine radiographs were reviewed to assess the clinical need for lateral L5/S1 projection. Modern film/screen combinations and gonadal shielding of externally scattered radiation play a major role in the reduction of the genetic dose. The number of exposures should be minimized. Our results show that two projections, anteroposterior (AP) and lateral, appear to be sufficient in routine radiography of the lumbar spine. (orig.)

  5. Cyclone Simulation via Action Minimization

    Science.gov (United States)

    Plotkin, D. A.; Weare, J.; Abbot, D. S.

    2016-12-01

    A postulated impact of climate change is an increase in intensity of tropical cyclones (TCs). This hypothesized effect results from the fact that TCs are powered subsaturated boundary layer air picking up water vapor from the surface ocean as it flows inwards towards the eye. This water vapor serves as the energy input for TCs, which can be idealized as heat engines. The inflowing air has a nearly identical temperature as the surface ocean; therefore, warming of the surface leads to a warmer atmospheric boundary layer. By the Clausius-Clapeyron relationship, warmer boundary layer air can hold more water vapor and thus results in more energetic storms. Changes in TC intensity are difficult to predict due to the presence of fine structures (e.g. convective structures and rainbands) with length scales of less than 1 km, while general circulation models (GCMs) generally have horizontal resolutions of tens of kilometers. The models are therefore unable to capture these features, which are critical to accurately simulating cyclone structure and intensity. Further, strong TCs are rare events, meaning that long multi-decadal simulations are necessary to generate meaningful statistics about intense TC activity. This adds to the computational expense, making it yet more difficult to generate accurate statistics about long-term changes in TC intensity due to global warming via direct simulation. We take an alternative approach, applying action minimization techniques developed in molecular dynamics to the WRF weather/climate model. We construct artificial model trajectories that lead from quiescent (TC-free) states to TC states, then minimize the deviation of these trajectories from true model dynamics. We can thus create Monte Carlo model ensembles that are biased towards cyclogenesis, which reduces computational expense by limiting time spent in non-TC states. This allows for: 1) selective interrogation of model states with TCs; 2) finding the likeliest paths for

  6. Minimalism through intraoperative functional mapping.

    Science.gov (United States)

    Berger, M S

    1996-01-01

    Intraoperative stimulation mapping may be used to avoid unnecessary risk to functional regions subserving language and sensori-motor pathways. Based on the data presented here, language localization is variable in the entire population, with only certainty existing for the inferior frontal region responsible for motor speech. Anatomical landmarks such as the anterior temporal tip for temporal lobe language sites and the posterior aspect of the lateral sphenoid wing for the frontal lobe language zones are unreliable in avoiding postoperative aphasias. Thus, individual mapping to identify essential language sites has the greatest likelihood of avoiding permanent deficits in naming, reading, and motor speech. In a similar approach, motor and sensory pathways from the cortex and underlying white matter may be reliably stimulated and mapped in both awake and asleep patients. Although these techniques require an additional operative time and equipment nominally priced, the result is often gratifying, as postoperative morbidity has been greatly reduced in the process of incorporating these surgical strategies. The patients quality of life is improved in terms of seizure control, with or without antiepileptic drugs. This avoids having to perform a second costly operative procedure, which is routinely done when extraoperative stimulation and recording is done via subdural grids. In addition, an aggressive tumor resection at the initial operation lengthens the time to tumor recurrence and often obviates the need for a subsequent reoperation. Thus, intraoperative functional mapping may be best alluded to as a surgical technique that results in "minimalism in the long term".

  7. Against explanatory minimalism in psychiatry

    Directory of Open Access Journals (Sweden)

    Tim eThornton

    2015-12-01

    Full Text Available The idea that psychiatry contains, in principle, a series of levels of explanation has been criticised both as empirically false but also, by Campbell, as unintelligible because it presupposes a discredited pre-Humean view of causation. Campbell’s criticism is based on an interventionist-inspired denial that mechanisms and rational connections underpin physical and mental causation respectively and hence underpin levels of explanation. These claims echo some superficially similar remarks in Wittgenstein’s Zettel. But attention to the context of Wittgenstein’s remarks suggests a reason to reject explanatory minimalism in psychiatry and reinstate a Wittgensteinian notion of level of explanation. Only in a context broader than the one provided by interventionism is the ascription of propositional attitudes, even in the puzzling case of delusions, justified. Such a view, informed by Wittgenstein, can reconcile the idea that the ascription mental phenomena presupposes a particular level of explanation with the rejection of an a priori claim about its connection to a neurological level of explanation.

  8. Against Explanatory Minimalism in Psychiatry.

    Science.gov (United States)

    Thornton, Tim

    2015-01-01

    The idea that psychiatry contains, in principle, a series of levels of explanation has been criticized not only as empirically false but also, by Campbell, as unintelligible because it presupposes a discredited pre-Humean view of causation. Campbell's criticism is based on an interventionist-inspired denial that mechanisms and rational connections underpin physical and mental causation, respectively, and hence underpin levels of explanation. These claims echo some superficially similar remarks in Wittgenstein's Zettel. But attention to the context of Wittgenstein's remarks suggests a reason to reject explanatory minimalism in psychiatry and reinstate a Wittgensteinian notion of levels of explanation. Only in a context broader than the one provided by interventionism is that the ascription of propositional attitudes, even in the puzzling case of delusions, justified. Such a view, informed by Wittgenstein, can reconcile the idea that the ascription mental phenomena presupposes a particular level of explanation with the rejection of an a priori claim about its connection to a neurological level of explanation.

  9. Robotic assisted minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Palep Jaydeep

    2009-01-01

    Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.

  10. Is non-minimal inflation eternal?

    International Nuclear Information System (INIS)

    Feng, Chao-Jun; Li, Xin-Zhou

    2010-01-01

    The possibility that the non-minimal coupling inflation could be eternal is investigated. We calculate the quantum fluctuation of the inflaton in a Hubble time and find that it has the same value as that in the minimal case in the slow-roll limit. Armed with this result, we have studied some concrete non-minimal inflationary models including the chaotic inflation and the natural inflation, in which the inflaton is non-minimally coupled to the gravity. We find that the non-minimal coupling inflation could be eternal in some parameter spaces.

  11. Gamma radiation in the conservation Cucurbita moschata processed minimally

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Lucia C.A.S.; Franco, Suely S.H.; Arthur, Valter, E-mail: lcasilva@cena.usp.br, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Laboratório de Radiobiologia e Ambiente; Harder, Márcia N.C., E-mail: marcia.harder@fatec.sp.gov.br [Faculdade de Tecnologia de Piracicaba (FATEC), Piracicaba, SP (Brazil). Dep. Roque Trevisan; Arthur, Paula B.; Pires, Juliana; Filho, Jorge C., E-mail: paula.arthur@hotmail.com, E-mail: gilmita@uol.com.br, E-mail: juliana.angelo@gmail.com [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The objective of the work was to evaluate the effect of gamma radiation on (Cucurbita moschata) processed minimally. The zucchinis were acquired in of Horticulture Department of the ESALQ/ USP, Piracicaba, SP. Brazil, and taken to the laboratory of Food Irradiation of CENA/USP, where they were washed in running water, peeled and cut in cubes. The squash cubes were dipped in a solution of sodium hypochlorite 15ml/L for 4 minutes and kept in plastic box (polypropylene). They were irradiated with doses of: 0 (control), 1.0 and 2.0 kGy, in a source of Cobalt-60, type Gammacell-220 with a dose rate of 0.666 kGy/h, and stored in temperature of 5°C. After 1, 3 and 7 days of irradiation were realized analyses of: color (factors L, a, b), pH, Brix and acidity. By obtained results conclude that there is not statistics difference between the treatments processed by irradiation and the control. Therefore the dose of 2.0 kGy can be used to reduce the level of microbial load without affects the physical chemical characteristics of minimally processed zucchini. (author)

  12. Gamma radiation in the conservation Cucurbita moschata processed minimally

    International Nuclear Information System (INIS)

    Silva, Lucia C.A.S.; Franco, Suely S.H.; Arthur, Valter

    2017-01-01

    The objective of the work was to evaluate the effect of gamma radiation on (Cucurbita moschata) processed minimally. The zucchinis were acquired in of Horticulture Department of the ESALQ/ USP, Piracicaba, SP. Brazil, and taken to the laboratory of Food Irradiation of CENA/USP, where they were washed in running water, peeled and cut in cubes. The squash cubes were dipped in a solution of sodium hypochlorite 15ml/L for 4 minutes and kept in plastic box (polypropylene). They were irradiated with doses of: 0 (control), 1.0 and 2.0 kGy, in a source of Cobalt-60, type Gammacell-220 with a dose rate of 0.666 kGy/h, and stored in temperature of 5°C. After 1, 3 and 7 days of irradiation were realized analyses of: color (factors L, a, b), pH, Brix and acidity. By obtained results conclude that there is not statistics difference between the treatments processed by irradiation and the control. Therefore the dose of 2.0 kGy can be used to reduce the level of microbial load without affects the physical chemical characteristics of minimally processed zucchini. (author)

  13. Waste Minimization Policy at the Romanian Nuclear Power Plant

    International Nuclear Information System (INIS)

    Andrei, V.; Daian, I.

    2002-01-01

    The radioactive waste management system at Cernavoda Nuclear Power Plant (NPP) in Romania was designed to maintain acceptable levels of safety for workers and to protect human health and the environment from exposure to unacceptable levels of radiation. In accordance with terminology of the International Atomic Energy Agency (IAEA), this system consists of the ''pretreatment'' of solid and organic liquid radioactive waste, which may include part or all of the following activities: collection, handling, volume reduction (by an in-drum compactor, if appropriate), and storage. Gaseous and aqueous liquid wastes are managed according to the ''dilute and discharge'' strategy. Taking into account the fact that treatment/conditioning and disposal technologies are still not established, waste minimization at the source is a priority environmental management objective, while waste minimization at the disposal stage is presently just a theoretical requirement for future adopted technologies . The necessary operational and maintenance procedures are in place at Cernavoda to minimize the production and contamination of waste. Administrative and technical measures are established to minimize waste volumes. Thus, an annual environmental target of a maximum 30 m3 of radioactive waste volume arising from operation and maintenance has been established. Within the first five years of operations at Cernavoda NPP, this target has been met. The successful implementation of the waste minimization policy has been accompanied by a cost reduction while the occupational doses for plant workers have been maintained at as low as reasonably practicable levels. This paper will describe key features of the waste management system along with the actual experience that has been realized with respect to minimizing the waste volumes at the Cernavoda NPP

  14. Minimal nuclear energy density functional

    Science.gov (United States)

    Bulgac, Aurel; Forbes, Michael McNeil; Jin, Shi; Perez, Rodrigo Navarro; Schunck, Nicolas

    2018-04-01

    We present a minimal nuclear energy density functional (NEDF) called "SeaLL1" that has the smallest number of possible phenomenological parameters to date. SeaLL1 is defined by seven significant phenomenological parameters, each related to a specific nuclear property. It describes the nuclear masses of even-even nuclei with a mean energy error of 0.97 MeV and a standard deviation of 1.46 MeV , two-neutron and two-proton separation energies with rms errors of 0.69 MeV and 0.59 MeV respectively, and the charge radii of 345 even-even nuclei with a mean error ɛr=0.022 fm and a standard deviation σr=0.025 fm . SeaLL1 incorporates constraints on the equation of state (EoS) of pure neutron matter from quantum Monte Carlo calculations with chiral effective field theory two-body (NN ) interactions at the next-to-next-to-next-to leading order (N3LO) level and three-body (NNN ) interactions at the next-to-next-to leading order (N2LO) level. Two of the seven parameters are related to the saturation density and the energy per particle of the homogeneous symmetric nuclear matter, one is related to the nuclear surface tension, two are related to the symmetry energy and its density dependence, one is related to the strength of the spin-orbit interaction, and one is the coupling constant of the pairing interaction. We identify additional phenomenological parameters that have little effect on ground-state properties but can be used to fine-tune features such as the Thomas-Reiche-Kuhn sum rule, the excitation energy of the giant dipole and Gamow-Teller resonances, the static dipole electric polarizability, and the neutron skin thickness.

  15. Minimal models of multidimensional computations.

    Directory of Open Access Journals (Sweden)

    Jeffrey D Fitzgerald

    2011-03-01

    Full Text Available The multidimensional computations performed by many biological systems are often characterized with limited information about the correlations between inputs and outputs. Given this limitation, our approach is to construct the maximum noise entropy response function of the system, leading to a closed-form and minimally biased model consistent with a given set of constraints on the input/output moments; the result is equivalent to conditional random field models from machine learning. For systems with binary outputs, such as neurons encoding sensory stimuli, the maximum noise entropy models are logistic functions whose arguments depend on the constraints. A constraint on the average output turns the binary maximum noise entropy models into minimum mutual information models, allowing for the calculation of the information content of the constraints and an information theoretic characterization of the system's computations. We use this approach to analyze the nonlinear input/output functions in macaque retina and thalamus; although these systems have been previously shown to be responsive to two input dimensions, the functional form of the response function in this reduced space had not been unambiguously identified. A second order model based on the logistic function is found to be both necessary and sufficient to accurately describe the neural responses to naturalistic stimuli, accounting for an average of 93% of the mutual information with a small number of parameters. Thus, despite the fact that the stimulus is highly non-Gaussian, the vast majority of the information in the neural responses is related to first and second order correlations. Our results suggest a principled and unbiased way to model multidimensional computations and determine the statistics of the inputs that are being encoded in the outputs.

  16. Westinghouse Hanford Company waste minimization actions

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.

    1988-09-01

    Companies that generate hazardous waste materials are now required by national regulations to establish a waste minimization program. Accordingly, in FY88 the Westinghouse Hanford Company formed a waste minimization team organization. The purpose of the team is to assist the company in its efforts to minimize the generation of waste, train personnel on waste minimization techniques, document successful waste minimization effects, track dollar savings realized, and to publicize and administer an employee incentive program. A number of significant actions have been successful, resulting in the savings of materials and dollars. The team itself has been successful in establishing some worthwhile minimization projects. This document briefly describes the waste minimization actions that have been successful to date. 2 refs., 26 figs., 3 tabs

  17. Irradiation treatment of minimally processed carrots for ensuring microbiological safety

    Science.gov (United States)

    Ashraf Chaudry, Muhammad; Bibi, Nizakat; Khan, Misal; Khan, Maazullah; Badshah, Amal; Jamil Qureshi, Muhammad

    2004-09-01

    Minimally processed fruits and vegetables are very common in developed countries and are gaining popularity in developing countries due to their convenience and freshness. However, minimally processing may result in undesirable changes in colour, taste and appearance due to the transfer of microbes from skin to the flesh. Irradiation is a well-known technology for elimination of microbial contamination. Food irradiation has been approved by 50 countries and is being applied commercially in USA. The purpose of this study was to evaluate the effect of irradiation on the quality of minimally processed carrots. Fresh carrots were peeled, sliced and PE packaged. The samples were irradiated (0, 0.5, 1.0, 2.0, 2.5, 3.0 kGy) and stored at 5°C for 2 weeks. The samples were analyzed for hardness, organoleptic acceptance and microbial load at 0, 7th and 15th day. The mean firmness of the control and all irradiated samples remained between 4.31 and 4.42 kg of force, showing no adverse effect of radiation dose. The effect of storage (2 weeks) was significant ( P10) in all other irradiated samples(1.0, 2.0, 2.5 and 3.0 kGy) after 2 weeks storage. No coliform or E. coli were detected in any of the samples (radiated or control) immediately after irradiation and during the entire storage period in minimally processed carrots. A dose of 2.0 kGy completely controlled the fungal and bacterial counts. The irradiated samples (2.0 kGy) were also acceptable sensorially.

  18. Irradiation treatment of minimally processed carrots for ensuring microbiological safety

    Energy Technology Data Exchange (ETDEWEB)

    Ashraf Chaudry, Muhammad; Bibi, Nizakat; Khan, Misal; Khan, Maazullah; Badshah, Amal; Jamil Qureshi, Muhammad

    2004-10-01

    Minimally processed fruits and vegetables are very common in developed countries and are gaining popularity in developing countries due to their convenience and freshness. However, minimally processing may result in undesirable changes in colour, taste and appearance due to the transfer of microbes from skin to the flesh. Irradiation is a well-known technology for elimination of microbial contamination. Food irradiation has been approved by 50 countries and is being applied commercially in USA. The purpose of this study was to evaluate the effect of irradiation on the quality of minimally processed carrots. Fresh carrots were peeled, sliced and PE packaged. The samples were irradiated (0, 0.5, 1.0, 2.0, 2.5, 3.0 kGy) and stored at 5 deg. C for 2 weeks. The samples were analyzed for hardness, organoleptic acceptance and microbial load at 0, 7th and 15th day. The mean firmness of the control and all irradiated samples remained between 4.31 and 4.42 kg of force, showing no adverse effect of radiation dose. The effect of storage (2 weeks) was significant (P< 0.05) with values ranging between 4.28 and 4.39 kg of force. The total bacterial counts at 5 deg. C for non-irradiated and 0.5 kGy irradiated samples were 6.3x10{sup 5} cfu/g, 3.0x10{sup 2} and few colonies(>10) in all other irradiated samples(1.0, 2.0, 2.5 and 3.0 kGy) after 2 weeks storage. No coliform or E. coli were detected in any of the samples (radiated or control) immediately after irradiation and during the entire storage period in minimally processed carrots. A dose of 2.0 kGy completely controlled the fungal and bacterial counts. The irradiated samples (2.0 kGy) were also acceptable sensorially.

  19. Irradiation treatment of minimally processed carrots for ensuring microbiological safety

    International Nuclear Information System (INIS)

    Ashraf Chaudry, Muhammad; Bibi, Nizakat; Khan, Misal; Khan, Maazullah; Badshah, Amal; Jamil Qureshi, Muhammad

    2004-01-01

    Minimally processed fruits and vegetables are very common in developed countries and are gaining popularity in developing countries due to their convenience and freshness. However, minimally processing may result in undesirable changes in colour, taste and appearance due to the transfer of microbes from skin to the flesh. Irradiation is a well-known technology for elimination of microbial contamination. Food irradiation has been approved by 50 countries and is being applied commercially in USA. The purpose of this study was to evaluate the effect of irradiation on the quality of minimally processed carrots. Fresh carrots were peeled, sliced and PE packaged. The samples were irradiated (0, 0.5, 1.0, 2.0, 2.5, 3.0 kGy) and stored at 5 deg. C for 2 weeks. The samples were analyzed for hardness, organoleptic acceptance and microbial load at 0, 7th and 15th day. The mean firmness of the control and all irradiated samples remained between 4.31 and 4.42 kg of force, showing no adverse effect of radiation dose. The effect of storage (2 weeks) was significant (P 5 cfu/g, 3.0x10 2 and few colonies(>10) in all other irradiated samples(1.0, 2.0, 2.5 and 3.0 kGy) after 2 weeks storage. No coliform or E. coli were detected in any of the samples (radiated or control) immediately after irradiation and during the entire storage period in minimally processed carrots. A dose of 2.0 kGy completely controlled the fungal and bacterial counts. The irradiated samples (2.0 kGy) were also acceptable sensorially

  20. Radiation processing of minimally processed fruits and vegetables to ensure microbiological safety

    International Nuclear Information System (INIS)

    Bandekar, J.R.; Saroj, S.D.; Shashidhar, R.; Dhokane, V.S.; Hajare, S.N.; Nagar, V.; Sharma, A.

    2009-01-01

    Minimally processed fruits and vegetables are in demand as they offer ready rich source of nutrients and convenience to consumers. However, these products are often unsafe due to contamination with harmful pathogens. Therefore, a study was carried out to analyze microbiological quality of minimally processed fruits, vegetables and sprouts and to optimize radiation dose necessary to ensure safety of these commodities. Microbiological quality of these products was found to be poor. Decimal reduction dose (D 10 ) for Salmonella Typhimurium and Listeria monocytogenes in these minimally processed foods (MPF) were in the range of 164 to 588 Gy. Radiation processing with 2 kGy dose of gamma radiation resulted in 5 log reduction of S. Typhimurium and 4 log reduction of L. monocytogenes. The treatment did not significantly affect nutritional, organoleptic and textural properties. These results suggest that radiation processing can ensure safety of these products. (author)

  1. Intravascular ultrasound based dose assessment in endovascular brachytherapy

    International Nuclear Information System (INIS)

    Catalano, Gianpiero; Tamburini, Vittorio; Colombo, Antonio; Nishida, Takahiro; Parisi, Giovanni; Mazzetta, Chiara; Orecchia, Roberto

    2003-01-01

    Background: the role of endovascular brachytherapy in restenosis prevention is well documented. Dose is usually prescribed at a fixed distance from the source axis by angiographic quantification of vessel diameter. Recently, intravascular ultrasound (IVUS) was introduced in dose prescription, allowing a better evaluation of the vessel anatomy. This study retrospectively explores the difference between prescription following angiographic vessel sizing and delivered dose calculated with IVUS. Methods and results: Seventeen lesions were studied with IVUS, identifying on irradiated segment, three sections on which measuring minimal and maximal distance from the centre of IVUS catheter to the adventitia; using dedicated software, corresponding doses were calculated. The dose ranged widely, with maximal and minimal values of 71.6 and 4.9 Gy; furthermore, heterogeneity in dose among different sections was observed. In the central section, the maximal dose was 206% of the one prescribed with the QCA model at 2 mm from the source axis, while the minimal dose was 96%. In proximal and distal sections, respective values were 182, 45, 243, and 122%. Conclusions: Our analysis confirmed the dose inhomogeneity delivered with an angiographic fixed-dose prescription strategy. A dose variation was found along the irradiated segment due to the differences in vessel thickness. IVUS emerged as an important tool in endovascular brachytherapy, especially for irregular-shaped vessels

  2. [Minimally invasive approach for cervical spondylotic radiculopathy].

    Science.gov (United States)

    Ding, Liang; Sun, Taicun; Huang, Yonghui

    2010-01-01

    To summarize the recent minimally invasive approach for cervical spondylotic radiculopathy (CSR). The recent literature at home and abroad concerning minimally invasive approach for CSR was reviewed and summarized. There were two techniques of minimally invasive approach for CSR at present: percutaneous puncture techniques and endoscopic techniques. The degenerate intervertebral disc was resected or nucleolysis by percutaneous puncture technique if CSR was caused by mild or moderate intervertebral disc herniations. The cervical microendoscopic discectomy and foraminotomy was an effective minimally invasive approach which could provide a clear view. The endoscopy techniques were suitable to treat CSR caused by foraminal osteophytes, lateral disc herniations, local ligamentum flavum thickening and spondylotic foraminal stenosis. The minimally invasive procedure has the advantages of simple handling, minimally invasive and low incidence of complications. But the scope of indications is relatively narrow at present.

  3. Corporate tax minimization and stock price reactions

    OpenAIRE

    Blaufus, Kay; Möhlmann, Axel; Schwäbe, Alexander

    2016-01-01

    Tax minimization strategies may lead to significant tax savings, which could, in turn, increase firm value. However, such strategies are also associated with significant costs, such as expected penalties and planning, agency, and reputation costs. The overall impact of firms' tax minimization strategies on firm value is, therefore, unclear. To investigate whether corporate tax minimization increases firm value, we analyze the stock price reaction to news concerning corporate tax avoidance or ...

  4. Safety control and minimization of radioactive wastes

    International Nuclear Information System (INIS)

    Wang Jinming; Rong Feng; Li Jinyan; Wang Xin

    2010-01-01

    Compared with the developed countries, the safety control and minimization of the radwastes in China are under-developed. The research of measures for the safety control and minimization of the radwastes is very important for the safety control of the radwastes, and the reduction of the treatment and disposal cost and environment radiation hazards. This paper has systematically discussed the safety control and the minimization of the radwastes produced in the nuclear fuel circulation, nuclear technology applications and the process of decommission of nuclear facilities, and has provided some measures and methods for the safety control and minimization of the radwastes. (authors)

  5. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  6. Minimizing electrode contamination in an electrochemical cell

    Science.gov (United States)

    Kim, Yu Seung; Zelenay, Piotr; Johnston, Christina

    2014-12-09

    An electrochemical cell assembly that is expected to prevent or at least minimize electrode contamination includes one or more getters that trap a component or components leached from a first electrode and prevents or at least minimizes them from contaminating a second electrode.

  7. Matthew Arnold and Minimal Competency Testing.

    Science.gov (United States)

    Tuman, Myron C.

    1979-01-01

    Presents arguments by Robert Lowe and Matthew Arnold on the 19th century British "Payment by Results" Plan, whereby schools received funds for students who passed minimal competency tests. Emphasizes that the Victorian experience produced acrimonious teachers with low morale and encourages contemporary minimal testing advocates not to…

  8. Minimally processed fruit salad enriched with Lactobacillus ...

    African Journals Online (AJOL)

    paula

    2015-06-17

    Jun 17, 2015 ... Minimal processing promotes browning of some vegetal tissues due to cell membrane disruption, which results in the release of oxidative enzymes. This study evaluated the efficiency of citric acid, ascorbic acid, sodium metabisulfite and L-cysteine hydrochloride to retard enzymatic browning of minimally.

  9. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  10. Y-12 Plant waste minimization strategy

    International Nuclear Information System (INIS)

    Kane, M.A.

    1987-01-01

    The 1984 Amendments to the Resource Conservation and Recovery Act (RCRA) mandate that waste minimization be a major element of hazardous waste management. In response to this mandate and the increasing costs for waste treatment, storage, and disposal, the Oak Ridge Y-12 Plant developed a waste minimization program to encompass all types of wastes. Thus, waste minimization has become an integral part of the overall waste management program. Unlike traditional approaches, waste minimization focuses on controlling waste at the beginning of production instead of the end. This approach includes: (1) substituting nonhazardous process materials for hazardous ones, (2) recycling or reusing waste effluents, (3) segregating nonhazardous waste from hazardous and radioactive waste, and (4) modifying processes to generate less waste or less toxic waste. An effective waste minimization program must provide the appropriate incentives for generators to reduce their waste and provide the necessary support mechanisms to identify opportunities for waste minimization. This presentation focuses on the Y-12 Plant's strategy to implement a comprehensive waste minimization program. This approach consists of four major program elements: (1) promotional campaign, (2) process evaluation for waste minimization opportunities, (3) waste generation tracking system, and (4) information exchange network. The presentation also examines some of the accomplishments of the program and issues which need to be resolved

  11. Making the Most of Minimalism in Music.

    Science.gov (United States)

    Geiersbach, Frederick J.

    1998-01-01

    Describes the minimalist movement in music. Discusses generations of minimalist musicians and, in general, the minimalist approach. Considers various ways that minimalist strategies can be integrated into the music classroom focusing on (1) minimalism and (2) student-centered composition and principles of minimalism for use with elementary band…

  12. The relative volume growth of minimal submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, V.

    2002-01-01

    The volume growth of certain well-defined subsets of minimal submanifolds in riemannian spaces are compared with the volume growth of balls and spheres ill space forms of constant curvature.......The volume growth of certain well-defined subsets of minimal submanifolds in riemannian spaces are compared with the volume growth of balls and spheres ill space forms of constant curvature....

  13. Specialized minimal PDFs for optimized LHC calculations

    NARCIS (Netherlands)

    Carrazza, Stefano; Forte, Stefano; Kassabov, Zahari; Rojo, Juan

    2016-01-01

    We present a methodology for the construction of parton distribution functions (PDFs) designed to provide an accurate representation of PDF uncertainties for specific processes or classes of processes with a minimal number of PDF error sets: specialized minimal PDF sets, or SM-PDFs. We construct

  14. Minimally processed fruit salad enriched with Lactobacillus ...

    African Journals Online (AJOL)

    Minimal processing promotes browning of some vegetal tissues due to cell membrane disruption, which results in the release of oxidative enzymes. This study evaluated the efficiency of citric acid, ascorbic acid, sodium metabisulfite and L-cysteine hydrochloride to retard enzymatic browning of minimally processed fruit ...

  15. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  16. Theories of minimalism in architecture: Post scriptum

    Directory of Open Access Journals (Sweden)

    Stevanović Vladimir

    2012-01-01

    Full Text Available Owing to the period of intensive development in the last decade of XX century, architectural phenomenon called Minimalism in Architecture was remembered as the Style of the Nineties, which is characterized, morphologically speaking, by simplicity and formal reduction. Simultaneously with its development in practice, on a theoretical level several dominant interpretative models were able to establish themselves. The new millennium and time distance bring new problems; therefore this paper represents a discussion on specific theorization related to Minimalism in Architecture that can bear the designation of post scriptum, because their development starts after the constitutional period of architectural minimalist discourse. In XXI century theories, the problem of definition of minimalism remains important topic, approached by theorists through resolving on the axis: Modernism - Minimal Art - Postmodernism - Minimalism in Architecture. With regard to this, analyzed texts can be categorized in two groups: 1 texts of affirmative nature and historical-associative approach in which minimalism is identified with anything that is simple and reduced, in an idealizing manner, relied mostly on the existing hypotheses; 2 critically oriented texts, in which authors reconsider adequacy of the very term 'minimalism' in the context of architecture and take a metacritical attitude towards previous texts.

  17. Technology applications for radioactive waste minimization

    International Nuclear Information System (INIS)

    Devgun, J.S.

    1994-01-01

    The nuclear power industry has achieved one of the most successful examples of waste minimization. The annual volume of low-level radioactive waste shipped for disposal per reactor has decreased to approximately one-fifth the volume about a decade ago. In addition, the curie content of the total waste shipped for disposal has decreased. This paper will discuss the regulatory drivers and economic factors for waste minimization and describe the application of technologies for achieving waste minimization for low-level radioactive waste with examples from the nuclear power industry

  18. Graphical approach for multiple values logic minimization

    Science.gov (United States)

    Awwal, Abdul Ahad S.; Iftekharuddin, Khan M.

    1999-03-01

    Multiple valued logic (MVL) is sought for designing high complexity, highly compact, parallel digital circuits. However, the practical realization of an MVL-based system is dependent on optimization of cost, which directly affects the optical setup. We propose a minimization technique for MVL logic optimization based on graphical visualization, such as a Karnaugh map. The proposed method is utilized to solve signed-digit binary and trinary logic minimization problems. The usefulness of the minimization technique is demonstrated for the optical implementation of MVL circuits.

  19. Minimal covariant observables identifying all pure states

    Energy Technology Data Exchange (ETDEWEB)

    Carmeli, Claudio, E-mail: claudio.carmeli@gmail.com [D.I.M.E., Università di Genova, Via Cadorna 2, I-17100 Savona (Italy); I.N.F.N., Sezione di Genova, Via Dodecaneso 33, I-16146 Genova (Italy); Heinosaari, Teiko, E-mail: teiko.heinosaari@utu.fi [Turku Centre for Quantum Physics, Department of Physics and Astronomy, University of Turku (Finland); Toigo, Alessandro, E-mail: alessandro.toigo@polimi.it [Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano (Italy); I.N.F.N., Sezione di Milano, Via Celoria 16, I-20133 Milano (Italy)

    2013-09-02

    It has been recently shown by Heinosaari, Mazzarella and Wolf (2013) [1] that an observable that identifies all pure states of a d-dimensional quantum system has minimally 4d−4 outcomes or slightly less (the exact number depending on d). However, no simple construction of this type of minimal observable is known. We investigate covariant observables that identify all pure states and have minimal number of outcomes. It is shown that the existence of this kind of observables depends on the dimension of the Hilbert space.

  20. Minimal free resolutions over complete intersections

    CERN Document Server

    Eisenbud, David

    2016-01-01

    This book introduces a theory of higher matrix factorizations for regular sequences and uses it to describe the minimal free resolutions of high syzygy modules over complete intersections. Such resolutions have attracted attention ever since the elegant construction of the minimal free resolution of the residue field by Tate in 1957. The theory extends the theory of matrix factorizations of a non-zero divisor, initiated by Eisenbud in 1980, which yields a description of the eventual structure of minimal free resolutions over a hypersurface ring. Matrix factorizations have had many other uses in a wide range of mathematical fields, from singularity theory to mathematical physics.

  1. Transience and capacity of minimal submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, V.

    2003-01-01

    We prove explicit lower bounds for the capacity of annular domains of minimal submanifolds P-m in ambient Riemannian spaces N-n with sectional curvatures bounded from above. We characterize the situations in which the lower bounds for the capacity are actually attained. Furthermore we apply...... these bounds to prove that Brownian motion defined on a complete minimal submanifold is transient when the ambient space is a negatively curved Hadamard-Cartan manifold. The proof stems directly from the capacity bounds and also covers the case of minimal submanifolds of dimension m > 2 in Euclidean spaces....

  2. Non-minimal Wu-Yang monopole

    International Nuclear Information System (INIS)

    Balakin, A.B.; Zayats, A.E.

    2007-01-01

    We discuss new exact spherically symmetric static solutions to non-minimally extended Einstein-Yang-Mills equations. The obtained solution to the Yang-Mills subsystem is interpreted as a non-minimal Wu-Yang monopole solution. We focus on the analysis of two classes of the exact solutions to the gravitational field equations. Solutions of the first class belong to the Reissner-Nordstroem type, i.e., they are characterized by horizons and by the singularity at the point of origin. The solutions of the second class are regular ones. The horizons and singularities of a new type, the non-minimal ones, are indicated

  3. Assessment of LANL waste minimization plan

    International Nuclear Information System (INIS)

    Davis, K.D.; McNair, D.A.; Jennrich, E.A.; Lund, D.M.

    1991-04-01

    The objective of this report is to evaluate the Los Alamos National Laboratory (LANL) Waste Minimization Plan to determine if it meets applicable internal (DOE) and regulatory requirements. The intent of the effort is to assess the higher level elements of the documentation to determine if they have been addressed rather than the detailed mechanics of the program's implementation. The requirement for a Waste Minimization Plan is based in several DOE Orders as well as environmental laws and regulations. Table 2-1 provides a list of the major documents or regulations that require waste minimization efforts. The table also summarizes the applicable requirements

  4. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  5. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  6. Patient dose in image guided radiotherapy: Monte Carlo study of the CBCT dose contribution

    OpenAIRE

    Leotta, Salvatore; Amato, Ernesto; Settineri, Nicola; Basile, Emilia; Italiano, Antonio; Auditore, Lucrezia; Santacaterina, Anna; Pergolizzi, Stefano

    2018-01-01

    Image Guided RadioTherapy (IGRT) is a technique whose diffusion is growing thanks to the well-recognized gain in accuracy of dose delivery. However, multiple Cone Beam Computed Tomography (CBCT) scans add dose to patients, and its contribution has to be assessed and minimized. Aim of our work was to evaluate, through Monte Carlo simulations, organ doses in IGRT due to CBCT and therapeutic MV irradiation in head-neck, thorax and pelvis districts. We developed a Monte Carlo simulation in GAMOS ...

  7. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators

    International Nuclear Information System (INIS)

    Belley, Matthew D.; Wang, Chu; Nguyen, Giao; Gunasingha, Rathnayaka; Chao, Nelson J.; Chen, Benny J.; Dewhirst, Mark W.; Yoshizumi, Terry T.

    2014-01-01

    Purpose: Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. Methods: Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. Results: Average doses in soft-tissue organs were found to vary by as much as 23%–32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. Conclusions: This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs

  8. Waste minimization and pollution prevention awareness plan

    Energy Technology Data Exchange (ETDEWEB)

    1991-05-31

    The purpose of this plan is to document the Lawrence Livermore National Laboratory (LLNL) Waste Minimization and Pollution Prevention Awareness Program. The plan specifies those activities and methods that are or will be employed to reduce the quantity and toxicity of wastes generated at the site. The intent of this plan is to respond to and comply with (DOE's) policy and guidelines concerning the need for pollution prevention. The Plan is composed of a LLNL Waste Minimization and Pollution Prevention Awareness Program Plan and, as attachments, Program- and Department-specific waste minimization plans. This format reflects the fact that waste minimization is considered a line management responsibility and is to be addressed by each of the Programs and Departments. 14 refs.

  9. On ``minimally curved spacetimes'' in general relativity

    OpenAIRE

    Dadhich, Naresh

    1997-01-01

    We consider a spacetime corresponding to uniform relativistic potential analogus to Newtonian potential as an example of ``minimally curved spacetime''. We also consider a radially symmetric analogue of the Rindler spacetime of uniform proper acceleration relative to infinity.

  10. Discrete Curvatures and Discrete Minimal Surfaces

    KAUST Repository

    Sun, Xiang

    2012-01-01

    This thesis presents an overview of some approaches to compute Gaussian and mean curvature on discrete surfaces and discusses discrete minimal surfaces. The variety of applications of differential geometry in visualization and shape design leads

  11. Waste minimization and pollution prevention awareness plan

    International Nuclear Information System (INIS)

    1991-01-01

    The purpose of this plan is to document the Lawrence Livermore National Laboratory (LLNL) Waste Minimization and Pollution Prevention Awareness Program. The plan specifies those activities and methods that are or will be employed to reduce the quantity and toxicity of wastes generated at the site. The intent of this plan is to respond to and comply with (DOE's) policy and guidelines concerning the need for pollution prevention. The Plan is composed of a LLNL Waste Minimization and Pollution Prevention Awareness Program Plan and, as attachments, Program- and Department-specific waste minimization plans. This format reflects the fact that waste minimization is considered a line management responsibility and is to be addressed by each of the Programs and Departments. 14 refs

  12. Minimal classical communication and measurement complexity for ...

    Indian Academy of Sciences (India)

    Minimal classical communication and measurement complexity for quantum ... Entanglement; teleportation; secret sharing; information splitting. ... Ahmedabad 380 009, India; Birla Institute of Technology and Science, Pilani 333 031, India ...

  13. A minimal architecture for joint action

    DEFF Research Database (Denmark)

    Vesper, Cordula; Butterfill, Stephen; Knoblich, Günther

    2010-01-01

    What kinds of processes and representations make joint action possible? In this paper we suggest a minimal architecture for joint action that focuses on representations, action monitoring and action prediction processes, as well as ways of simplifying coordination. The architecture spells out...... minimal requirements for an individual agent to engage in a joint action. We discuss existing evidence in support of the architecture as well as open questions that remain to be empirically addressed. In addition, we suggest possible interfaces between the minimal architecture and other approaches...... to joint action. The minimal architecture has implications for theorizing about the emergence of joint action, for human-machine interaction, and for understanding how coordination can be facilitated by exploiting relations between multiple agents’ actions and between actions and the environment....

  14. Providing intraosseous anesthesia with minimal invasion.

    Science.gov (United States)

    Giffin, K M

    1994-08-01

    A new variation of intraosseous anesthesia--crestal anesthesia--that is rapid, site-specific and minimally invasive is presented. The technique uses alveolar crest nutrient canals for anesthetic delivery without penetrating either bone or periodontal ligament.

  15. Minimal genera of open 4-manifolds

    OpenAIRE

    Gompf, Robert E.

    2013-01-01

    We study exotic smoothings of open 4-manifolds using the minimal genus function and its analog for end homology. While traditional techniques in open 4-manifold smoothing theory give no control of minimal genera, we make progress by using the adjunction inequality for Stein surfaces. Smoothings can be constructed with much more control of these genus functions than the compact setting seems to allow. As an application, we expand the range of 4-manifolds known to have exotic smoothings (up to ...

  16. Gravitino problem in minimal supergravity inflation

    Directory of Open Access Journals (Sweden)

    Fuminori Hasegawa

    2017-04-01

    Full Text Available We study non-thermal gravitino production in the minimal supergravity inflation. In this minimal model utilizing orthogonal nilpotent superfields, the particle spectrum includes only graviton, gravitino, inflaton, and goldstino. We find that a substantial fraction of the cosmic energy density can be transferred to the longitudinal gravitino due to non-trivial change of its sound speed. This implies either a breakdown of the effective theory after inflation or a serious gravitino problem.

  17. Gravitino problem in minimal supergravity inflation

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Fuminori [Institute for Cosmic Ray Research, The University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Mukaida, Kyohei [Kavli IPMU (WPI), UTIAS, The University of Tokyo, Kashiwa, Chiba 277-8583 (Japan); Nakayama, Kazunori [Department of Physics, Faculty of Science, The University of Tokyo, Bunkyo-ku, Tokyo 133-0033 (Japan); Terada, Takahiro, E-mail: terada@kias.re.kr [School of Physics, Korea Institute for Advanced Study (KIAS), Seoul 02455 (Korea, Republic of); Yamada, Yusuke [Stanford Institute for Theoretical Physics and Department of Physics, Stanford University, Stanford, CA 94305 (United States)

    2017-04-10

    We study non-thermal gravitino production in the minimal supergravity inflation. In this minimal model utilizing orthogonal nilpotent superfields, the particle spectrum includes only graviton, gravitino, inflaton, and goldstino. We find that a substantial fraction of the cosmic energy density can be transferred to the longitudinal gravitino due to non-trivial change of its sound speed. This implies either a breakdown of the effective theory after inflation or a serious gravitino problem.

  18. Flattening the inflaton potential beyond minimal gravity

    Directory of Open Access Journals (Sweden)

    Lee Hyun Min

    2018-01-01

    Full Text Available We review the status of the Starobinsky-like models for inflation beyond minimal gravity and discuss the unitarity problem due to the presence of a large non-minimal gravity coupling. We show that the induced gravity models allow for a self-consistent description of inflation and discuss the implications of the inflaton couplings to the Higgs field in the Standard Model.

  19. Minimally Invasive Surgery in Thymic Malignances

    Directory of Open Access Journals (Sweden)

    Wentao FANG

    2018-04-01

    Full Text Available Surgery is the most important therapy for thymic malignances. The last decade has seen increasing adoption of minimally invasive surgery (MIS for thymectomy. MIS for early stage thymoma patients has been shown to yield similar oncological results while being helpful in minimize surgical trauma, improving postoperative recovery, and reduce incisional pain. Meanwhile, With the advance in surgical techniques, the patients with locally advanced thymic tumors, preoperative induction therapies or recurrent diseases, may also benefit from MIS in selected cases.

  20. Minimal Function Graphs are not Instrumented

    DEFF Research Database (Denmark)

    Mycroft, Alan; Rosendahl, Mads

    1992-01-01

    The minimal function graph semantics of Jones and Mycroft is a standard denotational semantics modified to include only `reachable' parts of a program. We show that it may be expressed directly in terms of the standard semantics without the need for instrumentation at the expression level and......, in doing so, bring out a connection with strictness. This also makes it possible to prove a stronger theorem of correctness for the minimal function graph semantics....

  1. Minimal Dark Matter in the sky

    International Nuclear Information System (INIS)

    Panci, P.

    2016-01-01

    We discuss some theoretical and phenomenological aspects of the Minimal Dark Matter (MDM) model proposed in 2006, which is a theoretical framework highly appreciated for its minimality and yet its predictivity. We first critically review the theoretical requirements of MDM pointing out generalizations of this framework. Then we review the phenomenology of the originally proposed fermionic hyperchargeless electroweak quintuplet showing its main γ-ray tests.

  2. Effectiveness of radiation processing for elimination of Salmonella Typhimurium from minimally processed pineapple (Ananas comosus Merr.).

    Science.gov (United States)

    Shashidhar, Ravindranath; Dhokane, Varsha S; Hajare, Sachin N; Sharma, Arun; Bandekar, Jayant R

    2007-04-01

    The microbiological quality of market samples of minimally processed (MP) pineapple was examined. The effectiveness of radiation treatment in eliminating Salmonella Typhimurium from laboratory inoculated ready-to-eat pineapple slices was also studied. Microbiological quality of minimally processed pineapple samples from Mumbai market was poor; 8.8% of the samples were positive for Salmonella. D(10) (the radiation dose required to reduce bacterial population by 90%) value for S. Typhimurium inoculated in pineapple was 0.242 kGy. Inoculated pack studies in minimally processed pineapple showed that the treatment with a 2-kGy dose of gamma radiation could eliminate 5 log CFU/g of S. Typhimurium. The pathogen was not detected from radiation-processed samples up to 12 d during storage at 4 and 10 degrees C. The processing of market samples with 1 and 2 kGy was effective in improving the microbiological quality of these products.

  3. A survey on classical minimal surface theory

    CERN Document Server

    Meeks, William H

    2012-01-01

    Meeks and Pérez present a survey of recent spectacular successes in classical minimal surface theory. The classification of minimal planar domains in three-dimensional Euclidean space provides the focus of the account. The proof of the classification depends on the work of many currently active leading mathematicians, thus making contact with much of the most important results in the field. Through the telling of the story of the classification of minimal planar domains, the general mathematician may catch a glimpse of the intrinsic beauty of this theory and the authors' perspective of what is happening at this historical moment in a very classical subject. This book includes an updated tour through some of the recent advances in the theory, such as Colding-Minicozzi theory, minimal laminations, the ordering theorem for the space of ends, conformal structure of minimal surfaces, minimal annular ends with infinite total curvature, the embedded Calabi-Yau problem, local pictures on the scale of curvature and t...

  4. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Green, Patrick

    1992-01-01

    There is confusion over radiation dose limits between the International Commission on Radiological Protection, the National Radiological Protection Board and the Ministry of Agriculture, Fisheries and Food (MAFF), reports a Friends of the Earth's radiation campaigner. MAFF is suggesting the inadequate ICRP public dose limit does not apply to public exposures which arise from environmental contamination from past radioactive discharges. (author)

  5. Minimal string theories and integrable hierarchies

    Science.gov (United States)

    Iyer, Ramakrishnan

    Well-defined, non-perturbative formulations of the physics of string theories in specific minimal or superminimal model backgrounds can be obtained by solving matrix models in the double scaling limit. They provide us with the first examples of completely solvable string theories. Despite being relatively simple compared to higher dimensional critical string theories, they furnish non-perturbative descriptions of interesting physical phenomena such as geometrical transitions between D-branes and fluxes, tachyon condensation and holography. The physics of these theories in the minimal model backgrounds is succinctly encoded in a non-linear differential equation known as the string equation, along with an associated hierarchy of integrable partial differential equations (PDEs). The bosonic string in (2,2m-1) conformal minimal model backgrounds and the type 0A string in (2,4 m) superconformal minimal model backgrounds have the Korteweg-de Vries system, while type 0B in (2,4m) backgrounds has the Zakharov-Shabat system. The integrable PDE hierarchy governs flows between backgrounds with different m. In this thesis, we explore this interesting connection between minimal string theories and integrable hierarchies further. We uncover the remarkable role that an infinite hierarchy of non-linear differential equations plays in organizing and connecting certain minimal string theories non-perturbatively. We are able to embed the type 0A and 0B (A,A) minimal string theories into this single framework. The string theories arise as special limits of a rich system of equations underpinned by an integrable system known as the dispersive water wave hierarchy. We find that there are several other string-like limits of the system, and conjecture that some of them are type IIA and IIB (A,D) minimal string backgrounds. We explain how these and several other string-like special points arise and are connected. In some cases, the framework endows the theories with a non

  6. Waste minimization at Chalk River Laboratories

    International Nuclear Information System (INIS)

    Kranz, P.; Wong, P.C.F.

    2011-01-01

    Waste minimization supports Atomic Energy of Canada Limited (AECL) Environment Policy with regard to pollution prevention and has positive impacts on the environment, human health and safety, and economy. In accordance with the principle of pollution prevention, the quantities and degree of hazard of wastes requiring storage or disposition at facilities within or external to AECL sites shall be minimized, following the principles of Prevent, Reduce, Reuse, and Recycle, to the extent practical. Waste minimization is an important element in the Waste Management Program. The Waste Management Program has implemented various initiatives for waste minimization since 2007. The key initiatives have focused on waste reduction, segregation and recycling, and included: 1) developed waste minimization requirements and recycling procedure to establish the framework for applying the Waste Minimization Hierarchy; 2) performed waste minimization assessments for the facilities, which generate significant amounts of waste, to identify the opportunities for waste reduction and assist the waste generators to develop waste reduction targets and action plans to achieve the targets; 3) implemented the colour-coded, standardized waste and recycling containers to enhance waste segregation; 4) established partnership with external agents for recycling; 5) extended the likely clean waste and recyclables collection to selected active areas; 6) provided on-going communications to promote waste reduction and increase awareness for recycling; and 7) continually monitored performance, with respect to waste minimization, to identify opportunities for improvement and to communicate these improvements. After implementation of waste minimization initiatives at CRL, the solid waste volume generated from routine operations at CRL has significantly decreased, while the amount of recyclables diverted from the onsite landfill has significantly increased since 2007. The overall refuse volume generated at

  7. Sequential unconstrained minimization algorithms for constrained optimization

    International Nuclear Information System (INIS)

    Byrne, Charles

    2008-01-01

    The problem of minimizing a function f(x):R J → R, subject to constraints on the vector variable x, occurs frequently in inverse problems. Even without constraints, finding a minimizer of f(x) may require iterative methods. We consider here a general class of iterative algorithms that find a solution to the constrained minimization problem as the limit of a sequence of vectors, each solving an unconstrained minimization problem. Our sequential unconstrained minimization algorithm (SUMMA) is an iterative procedure for constrained minimization. At the kth step we minimize the function G k (x)=f(x)+g k (x), to obtain x k . The auxiliary functions g k (x):D subset of R J → R + are nonnegative on the set D, each x k is assumed to lie within D, and the objective is to minimize the continuous function f:R J → R over x in the set C = D-bar, the closure of D. We assume that such minimizers exist, and denote one such by x-circumflex. We assume that the functions g k (x) satisfy the inequalities 0≤g k (x)≤G k-1 (x)-G k-1 (x k-1 ), for k = 2, 3, .... Using this assumption, we show that the sequence {(x k )} is decreasing and converges to f(x-circumflex). If the restriction of f(x) to D has bounded level sets, which happens if x-circumflex is unique and f(x) is closed, proper and convex, then the sequence {x k } is bounded, and f(x*)=f(x-circumflex), for any cluster point x*. Therefore, if x-circumflex is unique, x* = x-circumflex and {x k } → x-circumflex. When x-circumflex is not unique, convergence can still be obtained, in particular cases. The SUMMA includes, as particular cases, the well-known barrier- and penalty-function methods, the simultaneous multiplicative algebraic reconstruction technique (SMART), the proximal minimization algorithm of Censor and Zenios, the entropic proximal methods of Teboulle, as well as certain cases of gradient descent and the Newton–Raphson method. The proof techniques used for SUMMA can be extended to obtain related results

  8. Waste minimization at Chalk River Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, P.; Wong, P.C.F. [Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    2011-07-01

    Waste minimization supports Atomic Energy of Canada Limited (AECL) Environment Policy with regard to pollution prevention and has positive impacts on the environment, human health and safety, and economy. In accordance with the principle of pollution prevention, the quantities and degree of hazard of wastes requiring storage or disposition at facilities within or external to AECL sites shall be minimized, following the principles of Prevent, Reduce, Reuse, and Recycle, to the extent practical. Waste minimization is an important element in the Waste Management Program. The Waste Management Program has implemented various initiatives for waste minimization since 2007. The key initiatives have focused on waste reduction, segregation and recycling, and included: 1) developed waste minimization requirements and recycling procedure to establish the framework for applying the Waste Minimization Hierarchy; 2) performed waste minimization assessments for the facilities, which generate significant amounts of waste, to identify the opportunities for waste reduction and assist the waste generators to develop waste reduction targets and action plans to achieve the targets; 3) implemented the colour-coded, standardized waste and recycling containers to enhance waste segregation; 4) established partnership with external agents for recycling; 5) extended the likely clean waste and recyclables collection to selected active areas; 6) provided on-going communications to promote waste reduction and increase awareness for recycling; and 7) continually monitored performance, with respect to waste minimization, to identify opportunities for improvement and to communicate these improvements. After implementation of waste minimization initiatives at CRL, the solid waste volume generated from routine operations at CRL has significantly decreased, while the amount of recyclables diverted from the onsite landfill has significantly increased since 2007. The overall refuse volume generated at

  9. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  10. Minimal Invasive Urologic Surgery and Postoperative Ileus

    Directory of Open Access Journals (Sweden)

    Fouad Aoun

    2015-07-01

    Full Text Available Postoperative ileus (POI is the most common cause of prolonged length of hospital stays (LOS and associated healthcare costs. The advent of minimal invasive technique was a major breakthrough in the urologic landscape with great potential to progress in the future. In the field of gastrointestinal surgery, several studies had reported lower incidence rates for POI following minimal invasive surgery compared to conventional open procedures. In contrast, little is known about the effect of minimal invasive approach on the recovery of bowel motility after urologic surgery. We performed an overview of the potential benefit of minimal invasive approach on POI for urologic procedures. The mechanisms and risk factors responsible for the onset of POI are discussed with emphasis on the advantages of minimal invasive approach. In the urologic field, POI is the main complication following radical cystectomy but it is rarely of clinical significance for other minimal invasive interventions. Laparoscopy or robotic assisted laparoscopic techniques when studied individually may reduce to their own the duration and prevent the onset of POI in a subset of procedures. The potential influence of age and urinary diversion type on postoperative ileus is contradictory in the literature. There is some evidence suggesting that BMI, blood loss, urinary extravasation, existence of a major complication, bowel resection, operative time and transperitoneal approach are independent risk factors for POI. Treatment of POI remains elusive. One of the most important and effective management strategies for patients undergoing radical cystectomy has been the development and use of enhanced recovery programs. An optimal rational strategy to shorten the duration of POI should incorporate minimal invasive approach when appropriate into multimodal fast track programs designed to reduce POI and shorten LOS.

  11. Minimalism in Art, Medical Science and Neurosurgery.

    Science.gov (United States)

    Okten, Ali Ihsan

    2018-01-01

    The word "minimalism" is a word derived from French the word "minimum". Whereas the lexical meaning of minimum is "the least or the smallest quantity necessary for something", its expression in mathematics can be described as "the lowest step a variable number can descend, least, minimal". Minimalism, which advocates an extreme simplicity of the artistic form, is a current in modern art and music whose origins go to 1960s and which features simplicity and objectivity. Although art, science and philosophy are different disciplines, they support each other from time to time, sometimes they intertwine and sometimes they copy each other. A periodic schools or teaching in one of them can take the others into itself, so, they proceed on their ways empowering each other. It is also true for the minimalism in art and the minimal invasive surgical approaches in science. Concepts like doing with less, avoiding unnecessary materials and reducing the number of the elements in order to increase the effect in the expression which are the main elements of the minimalism in art found their equivalents in medicine and neurosurgery. Their equivalents in medicine or neurosurgery have been to protect the physical integrity of the patient with less iatrogenic injury, minimum damage and the same therapeutic effect in the most effective way and to enable the patient to regain his health in the shortest span of time. As an anticipation, we can consider that the minimal approaches started by Richard Wollheim and Barbara Rose in art and Lars Leksell, Gazi Yaşargil and other neurosurgeons in neurosurgery in the 1960s are the present day equivalents of the minimalist approaches perhaps unconsciously started by Kazimir Malevich in art and Victor Darwin L"Espinasse in neurosurgery in the early 1900s. We can also consider that they have developed interacting with each other, not by chance.

  12. Blackfolds, plane waves and minimal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Armas, Jay [Physique Théorique et Mathématique, Université Libre de Bruxelles and International Solvay Institutes, ULB-Campus Plaine CP231, B-1050 Brussels (Belgium); Albert Einstein Center for Fundamental Physics, University of Bern,Sidlerstrasse 5, 3012 Bern (Switzerland); Blau, Matthias [Albert Einstein Center for Fundamental Physics, University of Bern,Sidlerstrasse 5, 3012 Bern (Switzerland)

    2015-07-29

    Minimal surfaces in Euclidean space provide examples of possible non-compact horizon geometries and topologies in asymptotically flat space-time. On the other hand, the existence of limiting surfaces in the space-time provides a simple mechanism for making these configurations compact. Limiting surfaces appear naturally in a given space-time by making minimal surfaces rotate but they are also inherent to plane wave or de Sitter space-times in which case minimal surfaces can be static and compact. We use the blackfold approach in order to scan for possible black hole horizon geometries and topologies in asymptotically flat, plane wave and de Sitter space-times. In the process we uncover several new configurations, such as black helicoids and catenoids, some of which have an asymptotically flat counterpart. In particular, we find that the ultraspinning regime of singly-spinning Myers-Perry black holes, described in terms of the simplest minimal surface (the plane), can be obtained as a limit of a black helicoid, suggesting that these two families of black holes are connected. We also show that minimal surfaces embedded in spheres rather than Euclidean space can be used to construct static compact horizons in asymptotically de Sitter space-times.

  13. Waste Minimization and Pollution Prevention Awareness Plan

    International Nuclear Information System (INIS)

    1992-01-01

    The purpose of this plan is to document the Lawrence Livermore National Laboratory (LLNL) Waste Minimization and Pollution Prevention Awareness Program. The plan specifies those activities and methods that are or will be employed to reduce the quantity and toxicity of wastes generated at the site. It is intended to satisfy Department of Energy (DOE) and other legal requirements that are discussed in Section C, below. The Pollution Prevention Awareness Program is included with the Waste Minimization Program as suggested by DOE Order 5400.1. The intent of this plan is to respond to and comply with the Department's policy and guidelines concerning the need for pollution prevention. The Plan is composed of a LLNL Waste Minimization and Pollution Prevention Awareness Program Plan and, as attachments, Directorate-, Program- and Department-specific waste minimization plans. This format reflects the fact that waste minimization is considered a line management responsibility and is to be addressed by each of the Directorates, Programs and Departments. Several Directorates have been reorganized, necessitating changes in the Directorate plans that were published in 1991

  14. Blackfolds, plane waves and minimal surfaces

    Science.gov (United States)

    Armas, Jay; Blau, Matthias

    2015-07-01

    Minimal surfaces in Euclidean space provide examples of possible non-compact horizon geometries and topologies in asymptotically flat space-time. On the other hand, the existence of limiting surfaces in the space-time provides a simple mechanism for making these configurations compact. Limiting surfaces appear naturally in a given space-time by making minimal surfaces rotate but they are also inherent to plane wave or de Sitter space-times in which case minimal surfaces can be static and compact. We use the blackfold approach in order to scan for possible black hole horizon geometries and topologies in asymptotically flat, plane wave and de Sitter space-times. In the process we uncover several new configurations, such as black helicoids and catenoids, some of which have an asymptotically flat counterpart. In particular, we find that the ultraspinning regime of singly-spinning Myers-Perry black holes, described in terms of the simplest minimal surface (the plane), can be obtained as a limit of a black helicoid, suggesting that these two families of black holes are connected. We also show that minimal surfaces embedded in spheres rather than Euclidean space can be used to construct static compact horizons in asymptotically de Sitter space-times.

  15. Image denoising by a direct variational minimization

    Directory of Open Access Journals (Sweden)

    Pilipović Stevan

    2011-01-01

    Full Text Available Abstract In this article we introduce a novel method for the image de-noising which combines a mathematically well-posdenes of the variational modeling with the efficiency of a patch-based approach in the field of image processing. It based on a direct minimization of an energy functional containing a minimal surface regularizer that uses fractional gradient. The minimization is obtained on every predefined patch of the image, independently. By doing so, we avoid the use of an artificial time PDE model with its inherent problems of finding optimal stopping time, as well as the optimal time step. Moreover, we control the level of image smoothing on each patch (and thus on the whole image by adapting the Lagrange multiplier using the information on the level of discontinuities on a particular patch, which we obtain by pre-processing. In order to reduce the average number of vectors in the approximation generator and still to obtain the minimal degradation, we combine a Ritz variational method for the actual minimization on a patch, and a complementary fractional variational principle. Thus, the proposed method becomes computationally feasible and applicable for practical purposes. We confirm our claims with experimental results, by comparing the proposed method with a couple of PDE-based methods, where we get significantly better denoising results specially on the oscillatory regions.

  16. On minimizers of causal variational principles

    International Nuclear Information System (INIS)

    Schiefeneder, Daniela

    2011-01-01

    Causal variational principles are a class of nonlinear minimization problems which arise in a formulation of relativistic quantum theory referred to as the fermionic projector approach. This thesis is devoted to a numerical and analytic study of the minimizers of a general class of causal variational principles. We begin with a numerical investigation of variational principles for the fermionic projector in discrete space-time. It is shown that for sufficiently many space-time points, the minimizing fermionic projector induces non-trivial causal relations on the space-time points. We then generalize the setting by introducing a class of causal variational principles for measures on a compact manifold. In our main result we prove under general assumptions that the support of a minimizing measure is either completely timelike, or it is singular in the sense that its interior is empty. In the examples of the circle, the sphere and certain flag manifolds, the general results are supplemented by a more detailed analysis of the minimizers. (orig.)

  17. Minimally conscious state or cortically mediated state?

    Science.gov (United States)

    Naccache, Lionel

    2018-04-01

    Durable impairments of consciousness are currently classified in three main neurological categories: comatose state, vegetative state (also recently coined unresponsive wakefulness syndrome) and minimally conscious state. While the introduction of minimally conscious state, in 2002, was a major progress to help clinicians recognize complex non-reflexive behaviours in the absence of functional communication, it raises several problems. The most important issue related to minimally conscious state lies in its criteria: while behavioural definition of minimally conscious state lacks any direct evidence of patient's conscious content or conscious state, it includes the adjective 'conscious'. I discuss this major problem in this review and propose a novel interpretation of minimally conscious state: its criteria do not inform us about the potential residual consciousness of patients, but they do inform us with certainty about the presence of a cortically mediated state. Based on this constructive criticism review, I suggest three proposals aiming at improving the way we describe the subjective and cognitive state of non-communicating patients. In particular, I present a tentative new classification of impairments of consciousness that combines behavioural evidence with functional brain imaging data, in order to probe directly and univocally residual conscious processes.

  18. Minimal knotted polygons in cubic lattices

    International Nuclear Information System (INIS)

    Van Rensburg, E J Janse; Rechnitzer, A

    2011-01-01

    In this paper we examine numerically the properties of minimal length knotted lattice polygons in the simple cubic, face-centered cubic, and body-centered cubic lattices by sieving minimal length polygons from a data stream of a Monte Carlo algorithm, implemented as described in Aragão de Carvalho and Caracciolo (1983 Phys. Rev. B 27 1635), Aragão de Carvalho et al (1983 Nucl. Phys. B 215 209) and Berg and Foester (1981 Phys. Lett. B 106 323). The entropy, mean writhe, and mean curvature of minimal length polygons are computed (in some cases exactly). While the minimal length and mean curvature are found to be lattice dependent, the mean writhe is found to be only weakly dependent on the lattice type. Comparison of our results to numerical results for the writhe obtained elsewhere (see Janse van Rensburg et al 1999 Contributed to Ideal Knots (Series on Knots and Everything vol 19) ed Stasiak, Katritch and Kauffman (Singapore: World Scientific), Portillo et al 2011 J. Phys. A: Math. Theor. 44 275004) shows that the mean writhe is also insensitive to the length of a knotted polygon. Thus, while these results for the mean writhe and mean absolute writhe at minimal length are not universal, our results demonstrate that these values are quite close the those of long polygons regardless of the underlying lattice and length

  19. Sensory, physicochemical and microbiological quality of irradiated minimally processed cauliflower

    International Nuclear Information System (INIS)

    Bib, Nizakat; Khan, Misal; Badshah, Amal; Ashraf Chaudry, Muhammad

    2005-01-01

    Minimally processed cauliflower samples were irradiated, stored at 5 deg C for 2 weeks and analyzed for sensory, physicochemical and microbiological qualities at 0th, 7th and 14th days. The data showed highest mean values of 7.93 and 7.57 for appearance and flavor, respectively, for 1.0 kGy treated samples. The D 10 values of contaminating microorganisms on cauliflower were 0.20 (Escherischia coli) and 0.24 kGy (Salmonella paratyphae A.) and the resulting 5D 10 value was 1.2 kGy. The study revealed that a dose of 1.5 kGy is enough for retention of quality and reduction of microbial load to 5D 10 values in cauliflower during 2 weeks storage at refrigerated temperature

  20. Mixed waste and waste minimization: The effect of regulations and waste minimization on the laboratory

    International Nuclear Information System (INIS)

    Dagan, E.B.; Selby, K.B.

    1993-08-01

    The Hanford Site is located in the State of Washington and is subject to state and federal environmental regulations that hamper waste minimization efforts. This paper addresses the negative effect of these regulations on waste minimization and mixed waste issues related to the Hanford Site. Also, issues are addressed concerning the regulations becoming more lenient. In addition to field operations, the Hanford Site is home to the Pacific Northwest Laboratory which has many ongoing waste minimization activities of particular interest to laboratories

  1. Minimal Length Scale Scenarios for Quantum Gravity.

    Science.gov (United States)

    Hossenfelder, Sabine

    2013-01-01

    We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  2. Advanced pyrochemical technologies for minimizing nuclear waste

    International Nuclear Information System (INIS)

    Bronson, M.C.; Dodson, K.E.; Riley, D.C.

    1994-01-01

    The Department of Energy (DOE) is seeking to reduce the size of the current nuclear weapons complex and consequently minimize operating costs. To meet this DOE objective, the national laboratories have been asked to develop advanced technologies that take uranium and plutonium, from retired weapons and prepare it for new weapons, long-term storage, and/or final disposition. Current pyrochemical processes generate residue salts and ceramic wastes that require aqueous processing to remove and recover the actinides. However, the aqueous treatment of these residues generates an estimated 100 liters of acidic transuranic (TRU) waste per kilogram of plutonium in the residue. Lawrence Livermore National Laboratory (LLNL) is developing pyrochemical techniques to eliminate, minimize, or more efficiently treat these residue streams. This paper will present technologies being developed at LLNL on advanced materials for actinide containment, reactors that minimize residues, and pyrochemical processes that remove actinides from waste salts

  3. Non-minimally coupled tachyon and inflation

    International Nuclear Information System (INIS)

    Piao Yunsong; Huang Qingguo; Zhang Xinmin; Zhang Yuanzhong

    2003-01-01

    In this Letter, we consider a model of tachyon with a non-minimal coupling to gravity and study its cosmological effects. Regarding inflation, we show that only for a specific coupling of tachyon to gravity this model satisfies observations and solves various problems which exist in the single and multi tachyon inflation models. But noting in the string theory the coupling coefficient of tachyon to gravity is of order g s , which in general is very small, we can hardly expect that the non-minimally coupling of tachyon to gravity could provide a reasonable tachyon inflation scenario. Our work may be a meaningful try for the cosmological effect of tachyon non-minimally coupled to gravity

  4. Minimal-change nephropathy and malignant thymoma.

    Science.gov (United States)

    Varsano, S; Bruderman, I; Bernheim, J L; Rathaus, M; Griffel, B

    1980-05-01

    A 56-year-old man had fever, precordial pain, and a mediastinal mass. The mass disappeared two months later and the patient remained asymptomatic for 2 1/2 years. At that time a full-blown nephrotic syndrome developed, with minimal-change glomerulopathy. The chest x-ray film showed the reappearance of a giant mediastinal mass. On biopsy of the mass, malignant thymoma was diagnosed. Association between minimal-change disease and Hodgkin's disease is well known, while the association with malignant thymoma has not been previously reported. The relationship between malignant thymoma and minimal-change disease is discussed, and a possible pathogenic mechanism involving cell-mediated immunity is proposed.

  5. Responsiveness and minimal clinically important change

    DEFF Research Database (Denmark)

    Christiansen, David Høyrup; Frost, Poul; Falla, Deborah

    2015-01-01

    Study Design A prospective cohort study nested in a randomized controlled trial. Objectives To determine and compare responsiveness and minimal clinically important change of the modified Constant score (CS) and the Oxford Shoulder Score (OSS). Background The OSS and the CS are commonly used...... to assess shoulder outcomes. However, few studies have evaluated the measurement properties of the OSS and CS in terms of responsiveness and minimal clinically important change. Methods The study included 126 patients who reported having difficulty returning to usual activities 8 to 12 weeks after...... were observed for the CS and the OSS. Minimal clinically important change ROC values were 6 points for the OSS and 11 points for the CS, with upper 95% cutoff limits of 12 and 22 points, respectively. Conclusion The CS and the OSS were both suitable for assessing improvement after decompression surgery....

  6. One-dimensional Gromov minimal filling problem

    International Nuclear Information System (INIS)

    Ivanov, Alexandr O; Tuzhilin, Alexey A

    2012-01-01

    The paper is devoted to a new branch in the theory of one-dimensional variational problems with branching extremals, the investigation of one-dimensional minimal fillings introduced by the authors. On the one hand, this problem is a one-dimensional version of a generalization of Gromov's minimal fillings problem to the case of stratified manifolds. On the other hand, this problem is interesting in itself and also can be considered as a generalization of another classical problem, the Steiner problem on the construction of a shortest network connecting a given set of terminals. Besides the statement of the problem, we discuss several properties of the minimal fillings and state several conjectures. Bibliography: 38 titles.

  7. Minimal entropy approximation for cellular automata

    International Nuclear Information System (INIS)

    Fukś, Henryk

    2014-01-01

    We present a method for the construction of approximate orbits of measures under the action of cellular automata which is complementary to the local structure theory. The local structure theory is based on the idea of Bayesian extension, that is, construction of a probability measure consistent with given block probabilities and maximizing entropy. If instead of maximizing entropy one minimizes it, one can develop another method for the construction of approximate orbits, at the heart of which is the iteration of finite-dimensional maps, called minimal entropy maps. We present numerical evidence that the minimal entropy approximation sometimes outperforms the local structure theory in characterizing the properties of cellular automata. The density response curve for elementary CA rule 26 is used to illustrate this claim. (paper)

  8. Approximate error conjugation gradient minimization methods

    Science.gov (United States)

    Kallman, Jeffrey S

    2013-05-21

    In one embodiment, a method includes selecting a subset of rays from a set of all rays to use in an error calculation for a constrained conjugate gradient minimization problem, calculating an approximate error using the subset of rays, and calculating a minimum in a conjugate gradient direction based on the approximate error. In another embodiment, a system includes a processor for executing logic, logic for selecting a subset of rays from a set of all rays to use in an error calculation for a constrained conjugate gradient minimization problem, logic for calculating an approximate error using the subset of rays, and logic for calculating a minimum in a conjugate gradient direction based on the approximate error. In other embodiments, computer program products, methods, and systems are described capable of using approximate error in constrained conjugate gradient minimization problems.

  9. Waste Minimization Measurement and Progress Reporting

    International Nuclear Information System (INIS)

    Stone, K.A.

    1995-01-01

    Westinghouse Savannah River Company is implementing productivity improvement concepts into the Waste Minimization Program by focusing on the positive initiatives taken to reduce waste generation at the Savannah River Site. Previous performance measures, based only on waste generation rates, proved to be an ineffective metric for measuring performance and promoting continuous improvements within the Program. Impacts of mission changes and non-routine operations impeded development of baseline waste generation rates and often negated waste generation trending reports. A system was developed to quantify, document and track innovative activities that impact waste volume and radioactivity/toxicity reductions. This system coupled with Management-driven waste disposal avoidance goals is proving to be a powerful tool to promote waste minimization awareness and the implementation of waste reduction initiatives. Measurement of waste not generated, in addition to waste generated, increases the credibility of the Waste Minimization Program, improves sharing of success stories, and supports development of regulatory and management reports

  10. Minimal Length Scale Scenarios for Quantum Gravity

    Directory of Open Access Journals (Sweden)

    Sabine Hossenfelder

    2013-01-01

    Full Text Available We review the question of whether the fundamental laws of nature limit our ability to probe arbitrarily short distances. First, we examine what insights can be gained from thought experiments for probes of shortest distances, and summarize what can be learned from different approaches to a theory of quantum gravity. Then we discuss some models that have been developed to implement a minimal length scale in quantum mechanics and quantum field theory. These models have entered the literature as the generalized uncertainty principle or the modified dispersion relation, and have allowed the study of the effects of a minimal length scale in quantum mechanics, quantum electrodynamics, thermodynamics, black-hole physics and cosmology. Finally, we touch upon the question of ways to circumvent the manifestation of a minimal length scale in short-distance physics.

  11. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  12. Insignificant levels of dose

    International Nuclear Information System (INIS)

    Webb, G.A.M.; McLean, A.S.

    1977-01-01

    The procedures recommended by the International Commission on Radiological Protection (ICRP) for making decisions concerning controllable sources of radiation exposure of the public include 'justification' and 'optimisation'. The tool recommended by the ICRP for reaching these decisions is collective dose or dose commitment supplemented by consideration of doses to individuals. In both these considerations the practical problem arises of whether very small doses to large numbers of people should contribute to the final decision-making process. It may be that at levels of dose which are small increments on natural background, the relationship between dose and effect is linear even though the slope may be close to zero. If so, collective dose is a meaningful concept and the calculation of total detriment for the purpose of justification could legitimately include all doses. In the calculation of collective doses for the purpose of optimisation, which involves decisions on how much money or resource should be allocated to dose reduction, it is necessary to appraise radiation detriment realistically. At low levels of dose to the individual such as those small by comparison with variations in natural background within the UK, the risk to the individual is such that his well-being will not be significantly changed by the presence or absence of the radiation dose. These small doses, which are well below the point at which an individual attaches significance, should not carry a societal significance. Societal acceptance of risk is analysed with a view to assessing a level of possible risk, and hence dose, below which resources should not in general be diverted to secure further reduction. A formulation for collective dose commitment is proposed incorporating a cut-off to exclude insignificant doses. The implications of this formulation in practical situations are discussed

  13. Review of Minimal Flavor Constraints for Technicolor

    DEFF Research Database (Denmark)

    S. Fukano, Hidenori; Sannino, Francesco

    2010-01-01

    We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self-coupling and mas......We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self...

  14. Evolved Minimal Frustration in Multifunctional Biomolecules.

    Science.gov (United States)

    Röder, Konstantin; Wales, David J

    2018-05-25

    Protein folding is often viewed in terms of a funnelled potential or free energy landscape. A variety of experiments now indicate the existence of multifunnel landscapes, associated with multifunctional biomolecules. Here, we present evidence that these systems have evolved to exhibit the minimal number of funnels required to fulfil their cellular functions, suggesting an extension to the principle of minimum frustration. We find that minimal disruptive mutations result in additional funnels, and the associated structural ensembles become more diverse. The same trends are observed in an atomic cluster. These observations suggest guidelines for rational design of engineered multifunctional biomolecules.

  15. Risk-optimized proton therapy to minimize radiogenic second cancers

    Science.gov (United States)

    Rechner, Laura A.; Eley, John G.; Howell, Rebecca M.; Zhang, Rui; Mirkovic, Dragan; Newhauser, Wayne D.

    2015-01-01

    Proton therapy confers substantially lower predicted risk of second cancer compared with photon therapy. However, no previous studies have used an algorithmic approach to optimize beam angle or fluence-modulation for proton therapy to minimize those risks. The objectives of this study were to demonstrate the feasibility of risk-optimized proton therapy and to determine the combination of beam angles and fluence weights that minimize the risk of second cancer in the bladder and rectum for a prostate cancer patient. We used 6 risk models to predict excess relative risk of second cancer. Treatment planning utilized a combination of a commercial treatment planning system and an in-house risk-optimization algorithm. When normal-tissue dose constraints were incorporated in treatment planning, the risk model that incorporated the effects of fractionation, initiation, inactivation, and repopulation selected a combination of anterior and lateral beams, which lowered the relative risk by 21% for the bladder and 30% for the rectum compared to the lateral-opposed beam arrangement. Other results were found for other risk models. PMID:25919133

  16. Radiation processing of minimally processed vegetables and aromatic plants

    International Nuclear Information System (INIS)

    Trigo, M.J.; Sousa, M.B.; Sapata, M.M.; Ferreira, A.; Curado, T.; Andrada, L.; Botelho, M.L.; Veloso, M.G.

    2009-01-01

    Vegetables are an essential part of people's diet all around the world. Due to cultivate techniques and handling after harvest, these products, may contain high microbial load that can cause food borne outbreaks. The irradiation of minimally processed vegetables is an efficient way to reduce the level of microorganisms and to inhibit parasites, helping a safe global trade. Evaluation of the irradiation's effects was carried out in minimal processed vegetables, as coriander (Coriandrum sativum L.), mint (Mentha spicata L.), parsley (Petroselinum crispum Mill, (A.W. Hill)), lettuce (Lactuca sativa L.) and watercress (Nasturium officinale L.). The inactivation level of natural microbiota and the D 10 values of Escherichia coli O157:H7 and Listeria innocua in these products were determined. The physical-chemical and sensorial characteristics before and after irradiation at a range of 0.5 up to 2.0 kGy applied doses were also evaluated. No differences were verified in the overall of sensorial and physical properties after irradiation up to 1 kGy, a decrease of natural microbiota was noticed (≥2 log). Based on the determined D 10 , the amount of radiation necessary to kill 10 5 E. coli and L. innocua was between 0.70 and 1.55 kGy. Shelf life of irradiated coriander, mint and lettuce at 0.5 kGy increased 2, 3 and 4 days, respectively, when compared with non-irradiated.

  17. Radiation processing of minimally processed vegetables and aromatic plants

    Energy Technology Data Exchange (ETDEWEB)

    Trigo, M.J. [Instituto Nacional dos Recursos Biologicos, L-INIA, Quinta do Marques, 2784-505 Oeiras (Portugal)], E-mail: mjptrigo@gmail.com; Sousa, M.B.; Sapata, M.M.; Ferreira, A.; Curado, T.; Andrada, L. [Instituto Nacional dos Recursos Biologicos, L-INIA, Quinta do Marques, 2784-505 Oeiras (Portugal); Botelho, M.L. [Instituto Tecnologico e Nuclear, E.N. 10, 2696 Sacavem (Portugal); Veloso, M.G. [Faculdade de Medicina Veterinaria de Lisboa, Av. da Universidade Tecnica, Alto da Ajuda, 1300-477 Lisboa (Portugal)

    2009-07-15

    Vegetables are an essential part of people's diet all around the world. Due to cultivate techniques and handling after harvest, these products, may contain high microbial load that can cause food borne outbreaks. The irradiation of minimally processed vegetables is an efficient way to reduce the level of microorganisms and to inhibit parasites, helping a safe global trade. Evaluation of the irradiation's effects was carried out in minimal processed vegetables, as coriander (Coriandrum sativum L.), mint (Mentha spicata L.), parsley (Petroselinum crispum Mill, (A.W. Hill)), lettuce (Lactuca sativa L.) and watercress (Nasturium officinale L.). The inactivation level of natural microbiota and the D{sub 10} values of Escherichia coli O157:H7 and Listeria innocua in these products were determined. The physical-chemical and sensorial characteristics before and after irradiation at a range of 0.5 up to 2.0 kGy applied doses were also evaluated. No differences were verified in the overall of sensorial and physical properties after irradiation up to 1 kGy, a decrease of natural microbiota was noticed ({>=}2 log). Based on the determined D{sub 10}, the amount of radiation necessary to kill 10{sup 5}E. coli and L. innocua was between 0.70 and 1.55 kGy. Shelf life of irradiated coriander, mint and lettuce at 0.5 kGy increased 2, 3 and 4 days, respectively, when compared with non-irradiated.

  18. Radiation processing of minimally processed vegetables and aromatic plants

    Science.gov (United States)

    Trigo, M. J.; Sousa, M. B.; Sapata, M. M.; Ferreira, A.; Curado, T.; Andrada, L.; Botelho, M. L.; Veloso, M. G.

    2009-07-01

    Vegetables are an essential part of people's diet all around the world. Due to cultivate techniques and handling after harvest, these products, may contain high microbial load that can cause food borne outbreaks. The irradiation of minimally processed vegetables is an efficient way to reduce the level of microorganisms and to inhibit parasites, helping a safe global trade. Evaluation of the irradiation's effects was carried out in minimal processed vegetables, as coriander ( Coriandrum sativum L .), mint ( Mentha spicata L.), parsley ( Petroselinum crispum Mill, (A.W. Hill)), lettuce ( Lactuca sativa L.) and watercress ( Nasturium officinale L.). The inactivation level of natural microbiota and the D 10 values of Escherichia coli O157:H7 and Listeria innocua in these products were determined. The physical-chemical and sensorial characteristics before and after irradiation at a range of 0.5 up to 2.0 kGy applied doses were also evaluated. No differences were verified in the overall of sensorial and physical properties after irradiation up to 1 kGy, a decrease of natural microbiota was noticed (⩾2 log). Based on the determined D10, the amount of radiation necessary to kill 10 5E. coli and L. innocua was between 0.70 and 1.55 kGy. Shelf life of irradiated coriander, mint and lettuce at 0.5 kGy increased 2, 3 and 4 days, respectively, when compared with non-irradiated.

  19. A mathematical approach to optimal selection of dose values in the additive dose method of ERP dosimetry

    International Nuclear Information System (INIS)

    Hayes, R.B.; Haskell, E.H.; Kenner, G.H.

    1996-01-01

    Additive dose methods commonly used in electron paramagnetic resonance (EPR) dosimetry are time consuming and labor intensive. We have developed a mathematical approach for determining optimal spacing of applied doses and the number of spectra which should be taken at each dose level. Expected uncertainitites in the data points are assumed to be normally distributed with a fixed standard deviation and linearity of dose response is also assumed. The optimum spacing and number of points necessary for the minimal error can be estimated, as can the likely error in the resulting estimate. When low doses are being estimated for tooth enamel samples the optimal spacing is shown to be a concentration of points near the zero dose value with fewer spectra taken at a single high dose value within the range of known linearity. Optimization of the analytical process results in increased accuracy and sample throughput

  20. Effects of oral bexarotene (targretin) on the minimal erythema dose for broadspectrum UVB light.

    NARCIS (Netherlands)

    Smit, J.V.; Jong, E.M.G.J. de; Kerkhof, P.C.M. van de

    2003-01-01

    Photo(chemo)therapy and oral retinoid therapy for psoriasis or cutaneous T-cell lymphoma are frequently combined to obtain an enhanced therapeutic effect with lower safety risks. Bexarotene, a new RXR-selective retinoid (rexinoid), has been developed for the treatment of cutaneous T-cell lymphoma

  1. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  2. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  3. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  4. Minimally inconsistent reasoning in Semantic Web.

    Science.gov (United States)

    Zhang, Xiaowang

    2017-01-01

    Reasoning with inconsistencies is an important issue for Semantic Web as imperfect information is unavoidable in real applications. For this, different paraconsistent approaches, due to their capacity to draw as nontrivial conclusions by tolerating inconsistencies, have been proposed to reason with inconsistent description logic knowledge bases. However, existing paraconsistent approaches are often criticized for being too skeptical. To this end, this paper presents a non-monotonic paraconsistent version of description logic reasoning, called minimally inconsistent reasoning, where inconsistencies tolerated in the reasoning are minimized so that more reasonable conclusions can be inferred. Some desirable properties are studied, which shows that the new semantics inherits advantages of both non-monotonic reasoning and paraconsistent reasoning. A complete and sound tableau-based algorithm, called multi-valued tableaux, is developed to capture the minimally inconsistent reasoning. In fact, the tableaux algorithm is designed, as a framework for multi-valued DL, to allow for different underlying paraconsistent semantics, with the mere difference in the clash conditions. Finally, the complexity of minimally inconsistent description logic reasoning is shown on the same level as the (classical) description logic reasoning.

  5. Microbial safety of minimally processed foods

    National Research Council Canada - National Science Library

    Novak, John S; Sapers, Gerald M; Juneja, Vijay K

    2003-01-01

    ...-course meals. All are expected to be portioned and minimally processed to balance the naturalness of unaltered foods with a concern for safety. Yet the responsibility for proper food preparation and handling remains with the naïve modern consumer, who may be less adept in food preparations than his or her less sophisticated ancestors. As a result,...

  6. Benefit from the minimally invasive sinus technique.

    Science.gov (United States)

    Salama, N; Oakley, R J; Skilbeck, C J; Choudhury, N; Jacob, A

    2009-02-01

    Sinus drainage is impeded by the transition spaces that the anterior paranasal sinuses drain into, not the ostia themselves. Addressing the transition spaces and leaving the ostia intact, using the minimally invasive sinus technique, should reverse chronic rhinosinusitis. To assess patient benefit following use of the minimally invasive sinus technique for chronic rhinosinusitis. One hundred and forty-three consecutive patients underwent the minimally invasive sinus technique for chronic rhinosinusitis. Symptoms (i.e. blocked nose, poor sense of smell, rhinorrhoea, post-nasal drip, facial pain and sneezing) were recorded using a visual analogue scale, pre-operatively and at six and 12 weeks post-operatively. Patients were also surveyed using the Glasgow benefit inventory, one and three years post-operatively. We found a significant reduction in all nasal symptom scores at six and 12 weeks post-operatively, and increased total quality of life scores at one and three years post-operatively (25.2 and 14.8, respectively). The patient benefits of treatment with the minimally invasive sinus technique compare with the published patient benefits for functional endoscopic sinus surgery.

  7. Towards the assembly of a minimal oscillator

    NARCIS (Netherlands)

    Nourian, Z.

    2015-01-01

    Life must have started with lower degree of complexity and connectivity. This statement readily triggers the question how simple is the simplest representation of life? In different words and considering a constructive approach, what are the requirements for creating a minimal cell? This thesis sets

  8. Waste minimization in a petrochemical company

    Energy Technology Data Exchange (ETDEWEB)

    Anan, Marcelo [Oxiteno S.A., Industria e Comercio, Sao Paulo, SP (Brazil)

    1993-12-31

    A way to manage industrial effluents consists in reducing their generation or treating them when elimination or minimization is economically unachievable. This work aims to present the modifications adopted in a petrochemical plant to adequate and, or, reduce the generation of industrial effluent. 8 refs., 3 figs.

  9. Minimizing convex functions by continuous descent methods

    Directory of Open Access Journals (Sweden)

    Sergiu Aizicovici

    2010-01-01

    Full Text Available We study continuous descent methods for minimizing convex functions, defined on general Banach spaces, which are associated with an appropriate complete metric space of vector fields. We show that there exists an everywhere dense open set in this space of vector fields such that each of its elements generates strongly convergent trajectories.

  10. A Generalized Random Regret Minimization Model

    NARCIS (Netherlands)

    Chorus, C.G.

    2013-01-01

    This paper presents, discusses and tests a generalized Random Regret Minimization (G-RRM) model. The G-RRM model is created by replacing a fixed constant in the attribute-specific regret functions of the RRM model, by a regret-weight variable. Depending on the value of the regret-weights, the G-RRM

  11. Prevention and minimization of waste production

    International Nuclear Information System (INIS)

    Noynaert, L.

    1998-01-01

    The main objective of the program Prevention and Minimization of Waste Production at the Belgian Nuclear Research Centre SCK/CEN is to contribute to reducing the volume and costs of nuclear waste. In addition, it aims to provide reliable data and models to the design engineers with a view to determining the final plant characteristics. Main activities in 1997 are described

  12. Kundt spacetimes minimally coupled to scalar field

    Energy Technology Data Exchange (ETDEWEB)

    Tahamtan, T. [Charles University, Institute of Theoretical Physics, Faculty of Mathematics and Physics, Prague 8 (Czech Republic); Astronomical Institute, Czech Academy of Sciences, Prague (Czech Republic); Svitek, O. [Charles University, Institute of Theoretical Physics, Faculty of Mathematics and Physics, Prague 8 (Czech Republic)

    2017-06-15

    We derive an exact solution belonging to the Kundt class of spacetimes both with and without a cosmological constant that are minimally coupled to a free massless scalar field. We show the algebraic type of these solutions and give interpretation of the results. Subsequently, we look for solutions additionally containing an electromagnetic field satisfying nonlinear field equations. (orig.)

  13. Modular invariance of N=2 minimal models

    International Nuclear Information System (INIS)

    Sidenius, J.

    1991-01-01

    We prove modular covariance of one-point functions at one loop in the diagonal N=2 minimal superconformal models. We use the recently derived general formalism for computing arbitrary conformal blocks in these models. Our result should be sufficient to guarantee modular covariance at arbitrary genus. It is thus an important check on the general formalism which is not manifestly modular covariant. (orig.)

  14. New Diagnostic Terminology for Minimal Brain Dysfunction.

    Science.gov (United States)

    Shaywitz, Bennett A.; And Others

    1979-01-01

    Minimal brain dysfunction has been redefined by the American Psychological Association as attention deficit disorder (ADD) and subdivided into categories with and without hyperactivity. The revised 'Diagnostic and Statistical Manual' (DSM III) is now undergoing field trials. Journal Availability: C. V. Mosby Company, 11830 Westline Industrial…

  15. Minimal representations and Freudenthal triple systems

    International Nuclear Information System (INIS)

    Olive, D.

    2004-01-01

    Unitary representations of noncompact Lie groups have long been sought in physics. The first nice concrete construction was found by Dirac in connection with the anti-de Sitter group. Some subsequent generalizations will be described, in particular the minimal representation thought to be relevant to realising duality in supergravity superstring theories. A relation to Freudenthal triple systems will be described. (author)

  16. Infrared dynamics of Minimal Walking Technicolor

    DEFF Research Database (Denmark)

    Del Debbio, Luigi; Lucini, Biagio; Patella, Agostino

    2010-01-01

    We study the gauge sector of Minimal Walking Technicolor, which is an SU(2) gauge theory with nf=2 flavors of Wilson fermions in the adjoint representation. Numerical simulations are performed on lattices Nt x Ns^3, with Ns ranging from 8 to 16 and Nt=2Ns, at fixed \\beta=2.25, and varying...

  17. Qualifying and quantifying minimal hepatic encephalopathy

    DEFF Research Database (Denmark)

    Morgan, Marsha Y; Amodio, Piero; Cook, Nicola A

    2016-01-01

    Minimal hepatic encephalopathy is the term applied to the neuropsychiatric status of patients with cirrhosis who are unimpaired on clinical examination but show alterations in neuropsychological tests exploring psychomotor speed/executive function and/or in neurophysiological variables. There is ......Minimal hepatic encephalopathy is the term applied to the neuropsychiatric status of patients with cirrhosis who are unimpaired on clinical examination but show alterations in neuropsychological tests exploring psychomotor speed/executive function and/or in neurophysiological variables...... analytical techniques may provide better diagnostic information while the advent of portable wireless headsets may facilitate more widespread use. A large number of other diagnostic tools have been validated for the diagnosis of minimal hepatic encephalopathy including Critical Flicker Frequency......, the Inhibitory Control Test, the Stroop test, the Scan package and the Continuous Reaction Time; each has its pros and cons; strengths and weaknesses; protagonists and detractors. Recent AASLD/EASL Practice Guidelines suggest that the diagnosis of minimal hepatic encephalopathy should be based on the PHES test...

  18. Nonunity gain minimal-disturbance measurement

    DEFF Research Database (Denmark)

    Sabuncu, Metin; Mišta, L.; Fiurášek, J.

    2007-01-01

    We propose and experimentally demonstrate an optimal nonunity gain Gaussian scheme for partial measurement of an unknown coherent state that causes minimal disturbance of the state. The information gain and the state disturbance are quantified by the noise added to the measurement outcomes...

  19. Obtaining a minimal set of rewrite rules

    CSIR Research Space (South Africa)

    Davel, M

    2005-11-01

    Full Text Available In this paper the authors describe a new approach to rewrite rule extraction and analysis, using Minimal Representation Graphs. This approach provides a mechanism for obtaining the smallest possible rule set – within a context-dependent rewrite rule...

  20. Mesonic spectroscopy of Minimal Walking Technicolor

    DEFF Research Database (Denmark)

    Del Debbio, Luigi; Lucini, Biagio; Patella, Agostino

    2010-01-01

    We investigate the structure and the novel emerging features of the mesonic non-singlet spectrum of the Minimal Walking Technicolor (MWT) theory. Precision measurements in the nonsinglet pseudoscalar and vector channels are compared to the expectations for an IR-conformal field theory and a QCD...

  1. Higher-Order Minimal Functional Graphs

    DEFF Research Database (Denmark)

    Jones, Neil D; Rosendahl, Mads

    1994-01-01

    We present a minimal function graph semantics for a higher-order functional language with applicative evaluation order. The semantics captures the intermediate calls performed during the evaluation of a program. This information may be used in abstract interpretation as a basis for proving...

  2. Banach spaces that realize minimal fillings

    International Nuclear Information System (INIS)

    Bednov, B. B.; Borodin, P. A.

    2014-01-01

    It is proved that a real Banach space realizes minimal fillings for all its finite subsets (a shortest network spanning a fixed finite subset always exists and has the minimum possible length) if and only if it is a predual of L 1 . The spaces L 1 are characterized in terms of Steiner points (medians). Bibliography: 25 titles. (paper)

  3. Minimally inconsistent reasoning in Semantic Web.

    Directory of Open Access Journals (Sweden)

    Xiaowang Zhang

    Full Text Available Reasoning with inconsistencies is an important issue for Semantic Web as imperfect information is unavoidable in real applications. For this, different paraconsistent approaches, due to their capacity to draw as nontrivial conclusions by tolerating inconsistencies, have been proposed to reason with inconsistent description logic knowledge bases. However, existing paraconsistent approaches are often criticized for being too skeptical. To this end, this paper presents a non-monotonic paraconsistent version of description logic reasoning, called minimally inconsistent reasoning, where inconsistencies tolerated in the reasoning are minimized so that more reasonable conclusions can be inferred. Some desirable properties are studied, which shows that the new semantics inherits advantages of both non-monotonic reasoning and paraconsistent reasoning. A complete and sound tableau-based algorithm, called multi-valued tableaux, is developed to capture the minimally inconsistent reasoning. In fact, the tableaux algorithm is designed, as a framework for multi-valued DL, to allow for different underlying paraconsistent semantics, with the mere difference in the clash conditions. Finally, the complexity of minimally inconsistent description logic reasoning is shown on the same level as the (classical description logic reasoning.

  4. Minimally processed vegetable salads: microbial quality evaluation.

    Science.gov (United States)

    Fröder, Hans; Martins, Cecília Geraldes; De Souza, Katia Leani Oliveira; Landgraf, Mariza; Franco, Bernadette D G M; Destro, Maria Teresa

    2007-05-01

    The increasing demand for fresh fruits and vegetables and for convenience foods is causing an expansion of the market share for minimally processed vegetables. Among the more common pathogenic microorganisms that can be transmitted to humans by these products are Listeria monocytogenes, Escherichia coli O157:H7, and Salmonella. The aim of this study was to evaluate the microbial quality of a selection of minimally processed vegetables. A total of 181 samples of minimally processed leafy salads were collected from retailers in the city of Sao Paulo, Brazil. Counts of total coliforms, fecal coliforms, Enterobacteriaceae, psychrotrophic microorganisms, and Salmonella were conducted for 133 samples. L. monocytogenes was assessed in 181 samples using the BAX System and by plating the enrichment broth onto Palcam and Oxford agars. Suspected Listeria colonies were submitted to classical biochemical tests. Populations of psychrotrophic microorganisms >10(6) CFU/g were found in 51% of the 133 samples, and Enterobacteriaceae populations between 10(5) and 106 CFU/g were found in 42% of the samples. Fecal coliform concentrations higher than 10(2) CFU/g (Brazilian standard) were found in 97 (73%) of the samples, and Salmonella was detected in 4 (3%) of the samples. Two of the Salmonella-positive samples had minimally processed vegetables had poor microbiological quality, and these products could be a vehicle for pathogens such as Salmonella and L. monocytogenes.

  5. Consequences of "Minimal" Group Affiliations in Children

    Science.gov (United States)

    Dunham, Yarrow; Baron, Andrew Scott; Carey, Susan

    2011-01-01

    Three experiments (total N = 140) tested the hypothesis that 5-year-old children's membership in randomly assigned "minimal" groups would be sufficient to induce intergroup bias. Children were randomly assigned to groups and engaged in tasks involving judgments of unfamiliar in-group or out-group children. Despite an absence of information…

  6. Systems for tracking minimally invasive surgical instruments

    NARCIS (Netherlands)

    Chmarra, M. K.; Grimbergen, C. A.; Dankelman, J.

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is

  7. An algorithm for reduct cardinality minimization

    KAUST Repository

    AbouEisha, Hassan M.

    2013-12-01

    This is devoted to the consideration of a new algorithm for reduct cardinality minimization. This algorithm transforms the initial table to a decision table of a special kind, simplify this table, and use a dynamic programming algorithm to finish the construction of an optimal reduct. Results of computer experiments with decision tables from UCI ML Repository are discussed. © 2013 IEEE.

  8. Waste minimization activity report for 1991

    International Nuclear Information System (INIS)

    Shoemaker, J.D.

    1992-01-01

    This is a waste reduction report for the Lawrence Livermore National Laboratory (LLNL) for 1991. The report covers the Main Site at Livermore and Site 300. Each research program at LLNL is described by its operation, administrative procedures, and waste minimization. Examples of the programs at LLNL are biomedical and environmental research, chemistry and materials science, and energy program and earth sciences. (MB)

  9. New trends in minimally invasive urological surgery

    Directory of Open Access Journals (Sweden)

    Prabhakar Rajan

    2009-10-01

    Full Text Available Purpose: The perceived benefits of minimally-invasive surgery include less postoperative pain, shorter hospitalization, reduced morbidity and better cosmesis while maintaining diagnostic accuracy and therapeutic outcome. We review the new trends in minimally-invasive urological surgery. Materials and method: We reviewed the English language literature using the National Library of Medicine database to identify the latest technological advances in minimally-invasive surgery with particular reference to urology. Results: Amongst other advances, studies incorporating needlescopic surgery, laparoendoscopic single-site surgery , magnetic anchoring and guidance systems, natural orifice transluminal endoscopic surgery and flexible robots were considered of interest. The results from initial animal and human studies are also outlined. Conclusion: Minimally-invasive surgery continues to evolve to meet the demands of the operators and patients. Many novel technologies are still in the testing phase, whilst others have entered clinical practice. Further evaluation is required to confirm the safety and efficacy of these techniques and validate the published reports.

  10. Harmonic manifolds with minimal horospheres are flat

    Indian Academy of Sciences (India)

    Abstract. In this note we reprove the known theorem: Harmonic manifolds with minimal horospheres are flat. It turns out that our proof is simpler and more direct than the original one. We also reprove the theorem: Ricci flat harmonic manifolds are flat, which is generally affirmed by appealing to Cheeger–Gromov splitting ...

  11. Harmonic Manifolds with Minimal Horospheres are Flat

    Indian Academy of Sciences (India)

    In this note we reprove the known theorem: Harmonic manifolds with minimal horospheres are flat. It turns out that our proof is simpler and more direct than the original one. We also reprove the theorem: Ricci flat harmonic manifolds are flat, which is generally affirmed by appealing to Cheeger–Gromov splitting theorem.

  12. Roughly isometric minimal immersions into Riemannian manifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen

    of the intrinsic combinatorial discrete Laplacian, and we will show that they share several analytic and geometric properties with their smooth (minimal submanifold) counterparts in $N$. The intrinsic properties thus obtained may hence serve as roughly invariant descriptors for the original metric space $X$....

  13. Minimally invasive treatments of uterine fibroids

    NARCIS (Netherlands)

    Voogt, M.J.

    2012-01-01

    This thesis assesses clinical results and technical developments of two minimally invasive treatments for symptomatic uterine fibroids: uterine artery embolization (UAE) and magnetic resonance-guided high intensity focused ultrasound (MR-HIFU). Part I: Uterine artery embolization The results of a

  14. Waste minimization in a petrochemical company

    Energy Technology Data Exchange (ETDEWEB)

    Anan, Marcelo [Oxiteno S.A., Industria e Comercio, Sao Paulo, SP (Brazil)

    1994-12-31

    A way to manage industrial effluents consists in reducing their generation or treating them when elimination or minimization is economically unachievable. This work aims to present the modifications adopted in a petrochemical plant to adequate and, or, reduce the generation of industrial effluent. 8 refs., 3 figs.

  15. An algorithm for reduct cardinality minimization

    KAUST Repository

    AbouEisha, Hassan M.; Al Farhan, Mohammed; Chikalov, Igor; Moshkov, Mikhail

    2013-01-01

    This is devoted to the consideration of a new algorithm for reduct cardinality minimization. This algorithm transforms the initial table to a decision table of a special kind, simplify this table, and use a dynamic programming algorithm to finish the construction of an optimal reduct. Results of computer experiments with decision tables from UCI ML Repository are discussed. © 2013 IEEE.

  16. Measures to minimize small intestine injury in the irradiated pelvis

    International Nuclear Information System (INIS)

    Green, N.; Iba, G.; Smith, W.R.

    1975-01-01

    Small intestine injury causes long-term suffering and high mortality. Five of 187 of our patients had developed serious small intestine injury. Four patients had corrective surgery. Three patients died. All were women. Subsequently, all patients who received definitive pelvic irradiation had small intestine roentgenograms to determine its location and mobility. Female patients, thin patients, and elderly patients had larger amounts of small intestine in the whole pelvis, a deeper cul de sac, and a greater incidence of relatively immobile small intestine. Patients with relatively immobile small intestine in the treatment field may be predisposed to injury. There was no relationship of the incidence of relatively immobile small intestine to prior pelvic surgery. We used the findings from the small intestine roentgenograms to modify individually the radiotherapy regimen so as to minimize the risk for small intestine injury. Patients were placed in the prone position to displace the small intestine out of the treatment fields used for booster dose irradiation. The treatment field was modified to exclude the small intestine. The total tumor dose delivered was determined by expectations for cure vs complications. To date, none of the patients in this study group has developed small intestine injury. Cadaver studies showed the feasibility of elective shortening of the pelvic cul de sac. The small intestine can be displaced away from the bladder, prostate, or cervix. (U.S.)

  17. Shelf life of irradiated minimally processed (MP) watercress (Nasturtium officinale)

    International Nuclear Information System (INIS)

    Martins, C.G.; Behrens, J.H.; Aragon-Alegro, L.C.; Vieira, V.S.; Costa-Sobrinho, P.S.; Vizeu, D.M.; Hutzler, B.; Franco, B.D.G. de M.; Destro, M.T.; Landgraf, M.

    2007-01-01

    This study was carried out to evaluate the shelf life of minimally processed (MP) watercress exposed to gamma radiation with doses of 1.0; 3.0; 4.0 kGy. Packaged irradiated and non-irradiated MP watercress was subject to sensory analysis. A panel consisting of 25-30 non-trained members, aged 20-55 years, was used. Sensory evaluation was carried out on days 0, 2, 5, 7, 9 and 12 after treatment with packages maintained at 7 °C. The members of the panel rated each sample for overall liking on a hybrid 10 hedonic scale (0 = extremely dislike; 10 = extremely like). Microbiological analyses were also conducted. Compared to the non-irradiated sample, 1 kGy irradiated watercress increased its shelf life by one day (16 days). Shelf lives of samples exposed to higher doses were reduced to 9 days (3 kGy) and 6 days (4 kGy) due to changes in appearance. The microbiological quality was good throughout the experiment

  18. Waste minimization applications at a remediation site

    International Nuclear Information System (INIS)

    Allmon, L.A.

    1995-01-01

    The Fernald Environmental Management Project (FEMP) owned by the Department of Energy was used for the processing of uranium. In 1989 Fernald suspended production of uranium metals and was placed on the National Priorities List (NPL). The site's mission has changed from one of production to environmental restoration. Many groups necessary for producing a product were deemed irrelevant for remediation work, including Waste Minimization. Waste Minimization does not readily appear to be applicable to remediation work. Environmental remediation is designed to correct adverse impacts to the environment from past operations and generates significant amounts of waste requiring management. The premise of pollution prevention is to avoid waste generation, thus remediation is in direct conflict with this premise. Although greater amounts of waste will be generated during environmental remediation, treatment capacities are not always available and disposal is becoming more difficult and costly. This creates the need for pollution prevention and waste minimization. Applying waste minimization principles at a remediation site is an enormous challenge. If the remediation site is also radiologically contaminated it is even a bigger challenge. Innovative techniques and ideas must be utilized to achieve reductions in the amount of waste that must be managed or dispositioned. At Fernald the waste minimization paradigm was shifted from focusing efforts on source reduction to focusing efforts on recycle/reuse by inverting the EPA waste management hierarchy. A fundamental difference at remediation sites is that source reduction has limited applicability to legacy wastes but can be applied successfully on secondary waste generation. The bulk of measurable waste reduction will be achieved by the recycle/reuse of primary wastes and by segregation and decontamination of secondary wastestreams. Each effort must be measured in terms of being economically and ecologically beneficial

  19. Minimally processed mixed salad submitted to gamma radiation: effects on bioactive compounds

    Energy Technology Data Exchange (ETDEWEB)

    Hirashima, Fabiana K.; Sabato, Susy F., E-mail: fmayumi@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Lanfer-Marquez, Ursula M., E-mail: lanferum@usp.br [Universidade de Sao Paulo (FCF/USP), Sao Paulo, SP (Brazil). Faculdade de Ciencias Farmaceuticas. Dept. de Alimentos e Nutricao Experimental

    2015-07-01

    High consumption of fruits and vegetables has been associated with a lowered incidence of oxidative stress-related diseases due to the presence of bioactive structures. Minimally processed products are a growing segment in food retail establishments because it is associated with practicality and convenience without significantly altering fresh-like characteristics. Low-dose of gamma radiation in combination with minimal processes has shown to be a promising strategy for extending shelf life and maintaining the organoleptic quality of fruits and vegetables. The objective of this study was to evaluate the levels of phenolic compounds, flavonoids, proanthocyanidins and antioxidant activity by 1,1-diphenyl-2-picrylhydrazyl (DPPH•) free radical scavenging and Oxygen Radical Absorbance Capacity (ORAC) method in minimally processed mixed salad before and after different radiation doses. Samples of minimally processed mixed salad (with green and red cabbage and carrot) were purchased at local supermarket and irradiated with doses of 0.5, 1.0, 2.0 and 3.0 kGy. Phenolic compounds, flavonoids, proanthocyanidins and antioxidant activity by DPPH• and ORAC were analyzed on the same extract prepared with MeOH. The results showed that bioactive compounds levels and antioxidant activity decreased significantly (p<0.05) with an increasing on radiation dose. Gamma-rays may affect these compounds and can cause degradation or oxidation, which can explain the drop on levels. Although the radiation has affected the bioactive contents, the process seems to be interesting to maintaining organoleptic characteristics and provide microbiological security at doses up to 2.0 kGy, according to studies conducted by our research group. (author)

  20. Minimally processed mixed salad submitted to gamma radiation: effects on bioactive compounds

    International Nuclear Information System (INIS)

    Hirashima, Fabiana K.; Sabato, Susy F.; Lanfer-Marquez, Ursula M.

    2015-01-01

    High consumption of fruits and vegetables has been associated with a lowered incidence of oxidative stress-related diseases due to the presence of bioactive structures. Minimally processed products are a growing segment in food retail establishments because it is associated with practicality and convenience without significantly altering fresh-like characteristics. Low-dose of gamma radiation in combination with minimal processes has shown to be a promising strategy for extending shelf life and maintaining the organoleptic quality of fruits and vegetables. The objective of this study was to evaluate the levels of phenolic compounds, flavonoids, proanthocyanidins and antioxidant activity by 1,1-diphenyl-2-picrylhydrazyl (DPPH•) free radical scavenging and Oxygen Radical Absorbance Capacity (ORAC) method in minimally processed mixed salad before and after different radiation doses. Samples of minimally processed mixed salad (with green and red cabbage and carrot) were purchased at local supermarket and irradiated with doses of 0.5, 1.0, 2.0 and 3.0 kGy. Phenolic compounds, flavonoids, proanthocyanidins and antioxidant activity by DPPH• and ORAC were analyzed on the same extract prepared with MeOH. The results showed that bioactive compounds levels and antioxidant activity decreased significantly (p<0.05) with an increasing on radiation dose. Gamma-rays may affect these compounds and can cause degradation or oxidation, which can explain the drop on levels. Although the radiation has affected the bioactive contents, the process seems to be interesting to maintaining organoleptic characteristics and provide microbiological security at doses up to 2.0 kGy, according to studies conducted by our research group. (author)

  1. Management of pediatric radiation dose using Philips fluoroscopy systems DoseWise: perfect image, perfect sense

    International Nuclear Information System (INIS)

    Stueve, Dick

    2006-01-01

    Although image quality (IQ) is the ultimate goal for accurate diagnosis and treatment, minimizing radiation dose is equally important. This is especially true when pediatric patients are examined, because their sensitivity to radiation-induced cancer is two to three times greater than that of adults. DoseWise is an ALARA-based philosophy within Philips Medical Systems that is active at every level of product design. It encompasses a set of techniques, programs and practices that ensures optimal IQ while protecting people in the X-ray environments. DoseWise methods include management of the X-ray beam, less radiation-on time and more dose information for the operator. Smart beam management provides automatic customization of the X-ray beam spectrum, shape, and pulse frequency. The Philips-patented grid-controlled fluoroscopy (GCF) provides grid switching of the X-ray beam in the X-ray tube instead of the traditional generator switching method. In the examination of pediatric patients, DoseWise technology has been scientifically documented to reduce radiation dose to <10% of the dose of traditional continuous fluoroscopy systems. The result is improved IQ at a significantly lower effective dose, which contributes to the safety of patients and staff. (orig.)

  2. Radiographic film: surface dose extrapolation techniques

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW; Currie, M.

    2004-01-01

    Full text: Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate 2 dimensional map of surface dose if required. Results have shown that surface % dose can be estimated within ±3% of parallel plate ionisation chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10cm, 20cmand 30cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. Corresponding parallel plate ionisation chamber measurement are 16%, 27% and 37% respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  3. Dose escalation of a curcuminoid formulation

    Directory of Open Access Journals (Sweden)

    Crowell James

    2006-03-01

    Full Text Available Abstract Background Curcumin is the major yellow pigment extracted from turmeric, a commonly-used spice in India and Southeast Asia that has broad anticarcinogenic and cancer chemopreventive potential. However, few systematic studies of curcumin's pharmacology and toxicology in humans have been performed. Methods A dose escalation study was conducted to determine the maximum tolerated dose and safety of a single dose of standardized powder extract, uniformly milled curcumin (C3 Complex™, Sabinsa Corporation. Healthy volunteers were administered escalating doses from 500 to 12,000 mg. Results Seven of twenty-four subjects (30% experienced only minimal toxicity that did not appear to be dose-related. No curcumin was detected in the serum of subjects administered 500, 1,000, 2,000, 4,000, 6,000 or 8,000 mg. Low levels of curcumin were detected in two subjects administered 10,000 or 12,000 mg. Conclusion The tolerance of curcumin in high single oral doses appears to be excellent. Given that achieving systemic bioavailability of curcumin or its metabolites may not be essential for colorectal cancer chemoprevention, these findings warrant further investigation for its utility as a long-term chemopreventive agent.

  4. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  5. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  6. Brachytherapy radiation doses to the neurovascular bundles

    International Nuclear Information System (INIS)

    Di Biase, Steven J.; Wallner, Kent; Tralins, Kevin; Sutlief, Steven

    2000-01-01

    , for whom detailed dosimetric and potency data are being collected prospectively. In the future, we anticipate that NVB doses may be incorporated into dosimetry guidelines to maximize tumor control and minimize treatment-related morbidity

  7. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  8. Minimal Left-Right Symmetric Dark Matter.

    Science.gov (United States)

    Heeck, Julian; Patra, Sudhanwa

    2015-09-18

    We show that left-right symmetric models can easily accommodate stable TeV-scale dark matter particles without the need for an ad hoc stabilizing symmetry. The stability of a newly introduced multiplet either arises accidentally as in the minimal dark matter framework or comes courtesy of the remaining unbroken Z_{2} subgroup of B-L. Only one new parameter is introduced: the mass of the new multiplet. As minimal examples, we study left-right fermion triplets and quintuplets and show that they can form viable two-component dark matter. This approach is, in particular, valid for SU(2)×SU(2)×U(1) models that explain the recent diboson excess at ATLAS in terms of a new charged gauge boson of mass 2 TeV.

  9. Commercial radioactive waste minimization program development guidance

    International Nuclear Information System (INIS)

    Fischer, D.K.

    1991-01-01

    This document is one of two prepared by the EG ampersand G Idaho, Inc., Waste Management Technical Support Program Group, National Low-Level Waste Management Program Unit. One of several Department of Energy responsibilities stated in the Amendments Act of 1985 is to provide technical assistance to compact regions Host States, and nonmember States (to the extent provided in appropriations acts) in establishing waste minimization program plans. Technical assistance includes, among other things, the development of technical guidelines for volume reduction options. Pursuant to this defined responsibility, the Department of Energy (through EG ampersand G Idaho, Inc.) has prepared this report, which includes guidance on defining a program, State/compact commission participation, and waste minimization program plans

  10. Minimal spanning trees, filaments and galaxy clustering

    International Nuclear Information System (INIS)

    Barrow, J.D.; Sonoda, D.H.

    1985-01-01

    A graph theoretical technique for assessing intrinsic patterns in point data sets is described. A unique construction, the minimal spanning tree, can be associated with any point data set given all the inter-point separations. This construction enables the skeletal pattern of galaxy clustering to be singled out in quantitative fashion and differs from other statistics applied to these data sets. This technique is described and applied to two- and three-dimensional distributions of galaxies and also to comparable random samples and numerical simulations. The observed CfA and Zwicky data exhibit characteristic distributions of edge-lengths in their minimal spanning trees which are distinct from those found in random samples. (author)

  11. Activity recognition from minimal distinguishing subsequence mining

    Science.gov (United States)

    Iqbal, Mohammad; Pao, Hsing-Kuo

    2017-08-01

    Human activity recognition is one of the most important research topics in the era of Internet of Things. To separate different activities given sensory data, we utilize a Minimal Distinguishing Subsequence (MDS) mining approach to efficiently find distinguishing patterns among different activities. We first transform the sensory data into a series of sensor triggering events and operate the MDS mining procedure afterwards. The gap constraints are also considered in the MDS mining. Given the multi-class nature of most activity recognition tasks, we modify the MDS mining approach from a binary case to a multi-class one to fit the need for multiple activity recognition. We also study how to select the best parameter set including the minimal and the maximal support thresholds in finding the MDSs for effective activity recognition. Overall, the prediction accuracy is 86.59% on the van Kasteren dataset which consists of four different activities for recognition.

  12. Discrete Curvatures and Discrete Minimal Surfaces

    KAUST Repository

    Sun, Xiang

    2012-06-01

    This thesis presents an overview of some approaches to compute Gaussian and mean curvature on discrete surfaces and discusses discrete minimal surfaces. The variety of applications of differential geometry in visualization and shape design leads to great interest in studying discrete surfaces. With the rich smooth surface theory in hand, one would hope that this elegant theory can still be applied to the discrete counter part. Such a generalization, however, is not always successful. While discrete surfaces have the advantage of being finite dimensional, thus easier to treat, their geometric properties such as curvatures are not well defined in the classical sense. Furthermore, the powerful calculus tool can hardly be applied. The methods in this thesis, including angular defect formula, cotangent formula, parallel meshes, relative geometry etc. are approaches based on offset meshes or generalized offset meshes. As an important application, we discuss discrete minimal surfaces and discrete Koenigs meshes.

  13. On Time with Minimal Expected Cost!

    DEFF Research Database (Denmark)

    David, Alexandre; Jensen, Peter Gjøl; Larsen, Kim Guldstrand

    2014-01-01

    (Priced) timed games are two-player quantitative games involving an environment assumed to be completely antogonistic. Classical analysis consists in the synthesis of strategies ensuring safety, time-bounded or cost-bounded reachability objectives. Assuming a randomized environment, the (priced......) timed game essentially defines an infinite-state Markov (reward) decision proces. In this setting the objective is classically to find a strategy that will minimize the expected reachability cost, but with no guarantees on worst-case behaviour. In this paper, we provide efficient methods for computing...... reachability strategies that will both ensure worst case time-bounds as well as provide (near-) minimal expected cost. Our method extends the synthesis algorithms of the synthesis tool Uppaal-Tiga with suitable adapted reinforcement learning techniques, that exhibits several orders of magnitude improvements w...

  14. Matrix factorizations, minimal models and Massey products

    International Nuclear Information System (INIS)

    Knapp, Johanna; Omer, Harun

    2006-01-01

    We present a method to compute the full non-linear deformations of matrix factorizations for ADE minimal models. This method is based on the calculation of higher products in the cohomology, called Massey products. The algorithm yields a polynomial ring whose vanishing relations encode the obstructions of the deformations of the D-branes characterized by these matrix factorizations. This coincides with the critical locus of the effective superpotential which can be computed by integrating these relations. Our results for the effective superpotential are in agreement with those obtained from solving the A-infinity relations. We point out a relation to the superpotentials of Kazama-Suzuki models. We will illustrate our findings by various examples, putting emphasis on the E 6 minimal model

  15. Investigations on quantum mechanics with minimal length

    International Nuclear Information System (INIS)

    Chargui, Yassine

    2009-01-01

    We consider a modified quantum mechanics where the coordinates and momenta are assumed to satisfy a non-standard commutation relation of the form( X i , P j ) = iℎ(δ ij (1+βP 2 )+β'P i P j ). Such an algebra results in a generalized uncertainty relation which leads to the existence of a minimal observable length. Moreover, it incorporates an UV/IR mixing and non commutative position space. We analyse the possible representations in terms of differential operators. The latter are used to study the low energy effects of the minimal length by considering different quantum systems : the harmonic oscillator, the Klein-Gordon oscillator, the spinless Salpeter Coulomb problem, and the Dirac equation with a linear confining potential. We also discuss whether such effects are observable in precision measurements on a relativistic electron trapped in strong magnetic field.

  16. Hydrogel-forming microneedle arrays: Potential for use in minimally-invasive lithium monitoring.

    Science.gov (United States)

    Eltayib, Eyman; Brady, Aaron J; Caffarel-Salvador, Ester; Gonzalez-Vazquez, Patricia; Zaid Alkilani, Ahlam; McCarthy, Helen O; McElnay, James C; Donnelly, Ryan F

    2016-05-01

    We describe, for the first time, hydrogel-forming microneedle (s) (MN) arrays for minimally-invasive extraction and quantification of lithium in vitro and in vivo. MN arrays, prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) and crosslinked by poly(ethyleneglycol), imbibed interstitial fluid (ISF) upon skin insertion. Such MN were always removed intact. In vitro, mean detected lithium concentrations showed no significant difference following 30min MN application to excised neonatal porcine skin for lithium citrate concentrations of 0.9 and 2mmol/l. However, after 1h application, the mean lithium concentrations extracted were significantly different, being appropriately concentration-dependent. In vivo, rats were orally dosed with lithium citrate equivalent to 15mg/kg and 30mg/kg lithium carbonate, respectively. MN arrays were applied 1h after dosing and removed 1h later. The two groups, having received different doses, showed no significant difference between lithium concentrations in serum or MN. However, the higher dosed rats demonstrated a lithium concentration extracted from MN arrays equivalent to a mean increase of 22.5% compared to rats which received the lower dose. Hydrogel-forming MN clearly have potential as a minimally-invasive tool for lithium monitoring in outpatient settings. We will now focus on correlation between serum and MN lithium concentrations. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Procedures minimally invasive image-guided

    International Nuclear Information System (INIS)

    Mora Guevara, Alejandro

    2011-01-01

    A literature review focused on minimally invasive procedures, has been performed at the Department of Radiology at the Hospital Calderon Guardia. A multidisciplinary team has been raised for decision making. The materials, possible complications and the available imaging technique such as ultrasound, computed tomography, magnetic resonance imaging, have been determined according to the procedure to be performed. The revision has supported medical interventions didactically enjoying the best materials, resources and conditions for a successful implementation of procedures and results [es

  18. Mean-field approximation minimizes relative entropy

    International Nuclear Information System (INIS)

    Bilbro, G.L.; Snyder, W.E.; Mann, R.C.

    1991-01-01

    The authors derive the mean-field approximation from the information-theoretic principle of minimum relative entropy instead of by minimizing Peierls's inequality for the Weiss free energy of statistical physics theory. They show that information theory leads to the statistical mechanics procedure. As an example, they consider a problem in binary image restoration. They find that mean-field annealing compares favorably with the stochastic approach

  19. Minimally invasive aesthetic procedures in young adults

    OpenAIRE

    Wollina, Uwe; Goldman, Alberto

    2011-01-01

    Uwe Wollina1, Alberto Goldman21Department of Dermatology and Allergology, Academic Teaching Hospital Dresden-Friedrichstadt, Dresden, Germany; 2Clinica Goldman, Porto Alegre, Rio Grande du Sul, BrazilAbstract: Age is a significant factor in modifying specific needs when it comes to medical aesthetic procedures. In this review we will focus on young adults in their third decade of life and review minimally invasive aesthetic procedures other than cosmetics and cosmeceuticals. Correction of asy...

  20. Minimizing the Fluid Used to Induce Fracturing

    Science.gov (United States)

    Boyle, E. J.

    2015-12-01

    The less fluid injected to induce fracturing means less fluid needing to be produced before gas is produced. One method is to inject as fast as possible until the desired fracture length is obtained. Presented is an alternative injection strategy derived by applying optimal system control theory to the macroscopic mass balance. The picture is that the fracture is constant in aperture, fluid is injected at a controlled rate at the near end, and the fracture unzips at the far end until the desired length is obtained. The velocity of the fluid is governed by Darcy's law with larger permeability for flow along the fracture length. Fracture growth is monitored through micro-seismicity. Since the fluid is assumed to be incompressible, the rate at which fluid is injected is balanced by rate of fracture growth and rate of loss to bounding rock. Minimizing injected fluid loss to the bounding rock is the same as minimizing total injected fluid How to change the injection rate so as to minimize the total injected fluid is a problem in optimal control. For a given total length, the variation of the injected rate is determined by variations in overall time needed to obtain the desired fracture length, the length at any time, and the rate at which the fracture is growing at that time. Optimal control theory leads to a boundary condition and an ordinary differential equation in time whose solution is an injection protocol that minimizes the fluid used under the stated assumptions. That method is to monitor the rate at which the square of the fracture length is growing and adjust the injection rate proportionately.

  1. Compositional Changes in Selected Minimally Processed Vegetables

    OpenAIRE

    O'Reilly, Emer, (Thesis)

    2000-01-01

    Compositional, physiological and microbiological changes in selected minimally processed vegetables packaged under a modified atmosphere of 2% oxygen and 5% carbon dioxide were monitored over a ten day storage period at 40 C and 80 C. The analysis targeted specific changes in the nutritional, chemical and physiological make up of the vegetables as well as the changes in the microbial levels. In addition the changes in the gas atmospheres within the packs were monitored. It has been widely acc...

  2. On 3D Minimal Massive Gravity

    CERN Document Server

    Alishahiha, Mohsen; Naseh, Ali; Shirzad, Ahmad

    2014-12-03

    We study linearized equations of motion of the newly proposed three dimensional gravity, known as minimal massive gravity, using its metric formulation. We observe that the resultant linearized equations are exactly the same as that of TMG by making use of a redefinition of the parameters of the model. In particular the model admits logarithmic modes at the critical points. We also study several vacuum solutions of the model, specially at a certain limit where the contribution of Chern-Simons term vanishes.

  3. Geometric Measure Theory and Minimal Surfaces

    CERN Document Server

    Bombieri, Enrico

    2011-01-01

    W.K. ALLARD: On the first variation of area and generalized mean curvature.- F.J. ALMGREN Jr.: Geometric measure theory and elliptic variational problems.- E. GIUSTI: Minimal surfaces with obstacles.- J. GUCKENHEIMER: Singularities in soap-bubble-like and soap-film-like surfaces.- D. KINDERLEHRER: The analyticity of the coincidence set in variational inequalities.- M. MIRANDA: Boundaries of Caciopoli sets in the calculus of variations.- L. PICCININI: De Giorgi's measure and thin obstacles.

  4. Prevention and Minimization of Waste Production

    International Nuclear Information System (INIS)

    Noynaert, L.; Bruggeman, A.; Rahier, A.

    1998-01-01

    The general objectives of SCK-CEN's programme on the prevention and minimization of waste production are to contribute to reducing volumes and cost of radioactive waste. It also aims tro provide reliable data and models to the design engineers with a view to determining the final plant characteristics. In the long term, these objectives will be extended to other nuclear applications. Progress and achievements in 1997 are summarised

  5. Separations: The path to waste minimization

    International Nuclear Information System (INIS)

    Bell, J.T.

    1992-01-01

    Waste materials usually are composed of large amounts of innocuous and frequently useful components mixed with lesser amounts of one or more hazardous components. The ultimate path to waste minimization is the separation of the lesser quantities of hazardous components from the innocuous components, and then recycle the useful components. This vision is so simple that everyone would be expected to properly manage waste. Several parameters interfere with this proper waste management, which encourages the open-quotes sweep it under the rugclose quotes or the open-quotes bury it allclose quotes attitudes, both of which delay and complicate proper waste management. The two primary parameters that interfere with proper waste management are: economics drives a process to a product without concerns of waste minimization, and emergency needs for immediate production of a product usually delays proper waste management. A third parameter in recent years is also interfering with proper waste management: quick relief of waste insults to political and public perceptions is promoting the open-quotes bury it allclose quotes attitude. A fourth parameter can promote better waste management for any scenario that suffers either or all of the first three parameters: separations technology can minimize wastes when the application of this technology is not voided by influence of the first three parameters. The US Department of Energy's management of nuclear waste has been seriously affected by the above four parameters. This paper includes several points about how the generation and management of DOE wastes have been, and continue to be, affected by these parameters. Particular separations technologies for minimizing the DOE wastes that must be stored for long periods are highlighted

  6. Radwaste minimization successes at Duke Power Company

    International Nuclear Information System (INIS)

    Lan, C.D.; Johnson, G.T.; Groves, D.C.; Smith, T.A.

    1996-01-01

    At Duke Power Company, open-quotes Culture Changeclose quotes is a common term that we have used to describe the incredible transformation. We are becoming a cost conscious, customer driven, highly competitive business. Nowhere has this change been more evident then in the way we process and dispose of our solid radioactive waste. With top-down management support, we have used team-based, formalized problem solving methods and have implemented many successful waste minimization programs. Through these programs, we have dramatically increased employees' awareness of the importance of waste minimization. As a result, we have been able to reduce both our burial volumes and our waste processing and disposal costs. In June, 1994, we invited EPRI to conduct assessments of our waste minimization programs at Oconee and Catawba nuclear stations. Included in the assessments were in-depth looks at contamination control, an inventory of items in the plant, the volume of waste generated in the plant and how it was processed, laundry reject data, site waste-handling operations, and plant open-quotes housekeepingclose quotes routines and process. One of the most important aspects of the assessment is the open-quotes dumpster dive,close quotes which is an evaluation of site dry active waste composition by sorting through approximately fifteen bags of radioactive waste. Finally, there was an evaluation of consumable used at each site in order to gain knowledge of items that could be standardized at all stations. With EPRI recommendations, we made several changes and standardized the items used. We have made significant progress in waste reduction. We realize, however, that we are aiming at a moving target and we still have room for improvement. As the price of processing and disposal (or storage) increases, we will continue to evaluate our waste minimization programs

  7. Minimally invasive surgery for esophageal achalasia

    OpenAIRE

    Bonavina, Luigi

    2006-01-01

    Esophageal achalasia is the most commonly diagnosed primary esophageal motor disorder and the second most common functional esophageal disorder. Current therapy of achalasia is directed toward elimination of the outflow resistance caused by failure of the lower esophageal sphincter to relax completely upon swallowing. The advent of minimally invasive surgery has nearly replaced endoscopic pneumatic dilation as the first-line therapeutic approach. In this editorial, the rationale and the evide...

  8. Asymptotic safety, emergence and minimal length

    International Nuclear Information System (INIS)

    Percacci, Roberto; Vacca, Gian Paolo

    2010-01-01

    There seems to be a common prejudice that asymptotic safety is either incompatible with, or at best unrelated to, the other topics in the title. This is not the case. In fact, we show that (1) the existence of a fixed point with suitable properties is a promising way of deriving emergent properties of gravity, and (2) there is a sense in which asymptotic safety implies a minimal length. In doing so we also discuss possible signatures of asymptotic safety in scattering experiments.

  9. Minimal access surgery for mitral valve endocarditis.

    Science.gov (United States)

    Barbero, Cristina; Marchetto, Giovanni; Ricci, Davide; Mancuso, Samuel; Boffini, Massimo; Cecchi, Enrico; De Rosa, Francesco Giuseppe; Rinaldi, Mauro

    2017-08-01

    Minimal access mitral valve surgery (MVS) has already proved to be feasible and effective with low perioperative mortality and excellent long-term outcomes. However, experience in more complex valve diseases such as infective endocarditis (IE) still remains limited. The aim of this retrospective study was to evaluate early and long-term results of minimal access MVS for IE. Data were entered into a dedicated database. Analysis was performed retrospectively for the 8-year period between January 2007 and April 2015. During the study period, 35 consecutive patients underwent minimal access MVS for IE at our department. Twenty-four had diagnosis of native MV endocarditis (68.6%) and 11 of mitral prosthesis endocarditis (31.4%).Thirty patients underwent early MVS (85.7%), and 5 patients were operated after the completion of antibiotic treatment (14.3%). Seven patients underwent MV repair (20%), 17 patients underwent MV replacement (48.6%), and 11 patients underwent mitral prosthesis replacement (31.4%). Thirty-day mortality was 11.4% (4 patients). No neurological or vascular complications were reported. One patient underwent reoperation for prosthesis IE relapse after 37 days. Overall actuarial survival rate at 1 and 5 years was 83%; freedom from MV reoperation and/or recurrence of IE at 1 and 5 years was 97%. Minimally invasive MVS for IE is feasible and associated with good early and long-term results. Preoperative accurate patient selection and transoesophageal echocardiography evaluation is mandatory for surgical planning. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Concept for quantifying the dose from image guided radiotherapy

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hälg, Roger; Besserer, Jürgen

    2015-01-01

    Radiographic image guidance is routinely used for patient positioning in radiotherapy. All radiographic guidance techniques can give a significant radiation dose to the patient. The dose from diagnostic imaging is usually managed by using effective dose minimization. In contrast, image-guided radiotherapy adds the imaging dose to an already high level of therapeutic radiation which cannot be easily managed using effective dose. The purpose of this work is the development of a concept of IGRT dose quantification which allows a comparison of imaging dose with commonly accepted variations of therapeutic dose. It is assumed that dose variations of the treatment beam which are accepted in the spirit of the ALARA convention can also be applied to the additional imaging dose. Therefore we propose three dose categories: Category I: The imaging dose is lower than a 2 % variation of the therapy dose. Category II: The imaging dose is larger than in category I, but lower than the therapy dose variations between different treatment techniques. Category III: The imaging dose is larger than in Category II. For various treatment techniques dose measurements are used to define the dose categories. The imaging devices were categorized according to the measured dose. Planar kV-kV imaging is a category I imaging procedure. kV-MV imaging is located at the edge between category I and II and is for increasing fraction size safely a category I imaging technique. MV-MV imaging is for all imaging technologies a category II procedure. MV fan beam CT for localization is a category I technology. Low dose protocols for kV CBCT are located between category I and II and are for increasing fraction size a category I imaging technique. All other investigated Pelvis-CBCT protocols are category II procedures. Fan beam CT scout views are category I technology. Live imaging modalities are category III for conventional fractionation, but category II for stereotactic treatments. Dose from radiotherapy

  11. Registration of radiation doses

    International Nuclear Information System (INIS)

    2000-02-01

    In Finland the Radiation and Nuclear Safety Authority (STUK) is maintaining the register (called Dose Register) of the radiation exposure of occupationally exposed workers in order to ensure compliance with the principles of optimisation and individual protection. The guide contains a description of the Dose Register and specifies the responsibilities of the party running a radiation practice to report the relevant information to the Dose Register

  12. Stabilization of a locally minimal forest

    Science.gov (United States)

    Ivanov, A. O.; Mel'nikova, A. E.; Tuzhilin, A. A.

    2014-03-01

    The method of partial stabilization of locally minimal networks, which was invented by Ivanov and Tuzhilin to construct examples of shortest trees with given topology, is developed. According to this method, boundary vertices of degree 2 are not added to all edges of the original locally minimal tree, but only to some of them. The problem of partial stabilization of locally minimal trees in a finite-dimensional Euclidean space is solved completely in the paper, that is, without any restrictions imposed on the number of edges remaining free of subdivision. A criterion for the realizability of such stabilization is established. In addition, the general problem of searching for the shortest forest connecting a finite family of boundary compact sets in an arbitrary metric space is formalized; it is shown that such forests exist for any family of compact sets if and only if for any finite subset of the ambient space there exists a shortest tree connecting it. The theory developed here allows us to establish further generalizations of the stabilization theorem both for arbitrary metric spaces and for metric spaces with some special properties. Bibliography: 10 titles.

  13. Conscious visual memory with minimal attention.

    Science.gov (United States)

    Pinto, Yair; Vandenbroucke, Annelinde R; Otten, Marte; Sligte, Ilja G; Seth, Anil K; Lamme, Victor A F

    2017-02-01

    Is conscious visual perception limited to the locations that a person attends? The remarkable phenomenon of change blindness, which shows that people miss nearly all unattended changes in a visual scene, suggests the answer is yes. However, change blindness is found after visual interference (a mask or a new scene), so that subjects have to rely on working memory (WM), which has limited capacity, to detect the change. Before such interference, however, a much larger capacity store, called fragile memory (FM), which is easily overwritten by newly presented visual information, is present. Whether these different stores depend equally on spatial attention is central to the debate on the role of attention in conscious vision. In 2 experiments, we found that minimizing spatial attention almost entirely erases visual WM, as expected. Critically, FM remains largely intact. Moreover, minimally attended FM responses yield accurate metacognition, suggesting that conscious memory persists with limited spatial attention. Together, our findings help resolve the fundamental issue of how attention affects perception: Both visual consciousness and memory can be supported by only minimal attention. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Minimally-aggressive gestational trophoblastic neoplasms.

    Science.gov (United States)

    Cole, Laurence A

    2012-04-01

    We have previously defined a new syndrome "Minimally-aggressive gestational trophoblastic neoplasms" in which choriocarcinoma or persistent hydatidiform mole has a minimal growth rate and becomes chemorefractory. Previously we described a new treatment protocol, waiting for hCG rise to >3000 mIU/ml and disease becomes more advanced, then using combination chemotherapy. Initially we found this treatment successful in 8 of 8 cases, here we find this protocol appropriate in a further 16 cases. Initially we used hyperglycosylated hCG, a limited availability test, to identify this syndrome. Here we propose also using hCG doubling rate to detect this syndrome. Minimally aggressive gestational trophoblastic disease can be detected by chemotherapy resistance or low hyperglycosylated hCG, disease by hyperglycosylated hCG and by hCG doubling test. All were recommended to hold off further chemotherapy until hCG >3000mIU/ml. One case died prior to the start of the study, one case withdrew because of a lung nodule and one withdrew refusing the suggested combination chemotherapy. The remaining 16 women were all successfully treated. A total of 8 plus 16 or 24 of 24 women were successfully treated using the proposed protocol, holding back on chemotherapy until hCG >3000mIU/ml. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. What is Quantum Mechanics? A Minimal Formulation

    Science.gov (United States)

    Friedberg, R.; Hohenberg, P. C.

    2018-03-01

    This paper presents a minimal formulation of nonrelativistic quantum mechanics, by which is meant a formulation which describes the theory in a succinct, self-contained, clear, unambiguous and of course correct manner. The bulk of the presentation is the so-called "microscopic theory", applicable to any closed system S of arbitrary size N, using concepts referring to S alone, without resort to external apparatus or external agents. An example of a similar minimal microscopic theory is the standard formulation of classical mechanics, which serves as the template for a minimal quantum theory. The only substantive assumption required is the replacement of the classical Euclidean phase space by Hilbert space in the quantum case, with the attendant all-important phenomenon of quantum incompatibility. Two fundamental theorems of Hilbert space, the Kochen-Specker-Bell theorem and Gleason's theorem, then lead inevitably to the well-known Born probability rule. For both classical and quantum mechanics, questions of physical implementation and experimental verification of the predictions of the theories are the domain of the macroscopic theory, which is argued to be a special case or application of the more general microscopic theory.

  16. On minimalism in architecture - space as experience

    Directory of Open Access Journals (Sweden)

    Vasilski Dragana

    2016-01-01

    Full Text Available Architecture has to be experienced to be understood. The complexity of the experience is seen through a better understanding of the relationship between objectivity (architecture and subjectivity (our life. Being physically, emotionally and psychologically aware of the space we occupy is an experience that could be described as being present, which is a sensation that is personal and difficult to explicitly describe. Research into experience through perception and emotion positions architecture within scientific fields, in particular psychological disciplines. Relying on the standpoints of Immanuel Kant, the paper considers the juxtaposition between (minimalism in architecture and philosophy on the topic of experience. Starting from the basic aspects of perception and representation of the world around us, a thesis is presented in which the notions of silence and light as experienced in minimalism (in architecture are considered as adequate counterparts to Kant’s factors of experience - the awareness of the objective order of events and the impossibility to perceive time itself. Through a case study we verify the starting hypothesis on minimalism (in architecture whereby space becomes an experience of how the world touches us.

  17. Minimization and segregation of radioactive wastes

    International Nuclear Information System (INIS)

    1992-07-01

    The report will serve as one of a series of technical manuals providing reference material and direct know-how to staff in radioisotope user establishments and research centres in Member States without nuclear power and the associated range of complex waste management operations. Considerations are limited to the minimization and segregation of wastes, these being initial steps on which the efficiency of the whole waste management system depends. The minimization and segregation operations are examined in the context of the restricted quantities and predominantly shorter lived activities of wastes from nuclear research, production and usage of radioisotopes. Liquid and solid wastes only are considered in the report. Gaseous waste minimization and treatment are specialized subjects and are not examined in this document. Gaseous effluent treatment in facilities handling low and intermediate level radioactive materials has been already the subject of a detailed IAEA report. Management of spent sealed sources has specifically been covered in a previous manual. Conditioned sealed sources must be taken into account in segregation arrangements for interim storage and disposal where there are exceptional long lived highly radiotoxic isotopes, particularly radium or americium. These are unlikely ever to be suitable for shallow land burial along with the remaining wastes. 30 refs, 5 figs, 8 tabs

  18. On balanced minimal repeated measurements designs

    Directory of Open Access Journals (Sweden)

    Shakeel Ahmad Mir

    2014-10-01

    Full Text Available Repeated Measurements designs are concerned with scientific experiments in which each experimental unit is assigned more than once to a treatment either different or identical. This class of designs has the property that the unbiased estimators for elementary contrasts among direct and residual effects are obtainable. Afsarinejad (1983 provided a method of constructing balanced Minimal Repeated Measurements designs p < t , when t is an odd or prime power, one or more than one treatment may occur more than once in some sequences and  designs so constructed no longer remain uniform in periods. In this paper an attempt has been made to provide a new method to overcome this drawback. Specifically, two cases have been considered                RM[t,n=t(t-t/(p-1,p], λ2=1 for balanced minimal repeated measurements designs and  RM[t,n=2t(t-t/(p-1,p], λ2=2 for balanced  repeated measurements designs. In addition , a method has been provided for constructing              extra-balanced minimal designs for special case RM[t,n=t2/(p-1,p], λ2=1.

  19. Opportunity Loss Minimization and Newsvendor Behavior

    Directory of Open Access Journals (Sweden)

    Xinsheng Xu

    2017-01-01

    Full Text Available To study the decision bias in newsvendor behavior, this paper introduces an opportunity loss minimization criterion into the newsvendor model with backordering. We apply the Conditional Value-at-Risk (CVaR measure to hedge against the potential risks from newsvendor’s order decision. We obtain the optimal order quantities for a newsvendor to minimize the expected opportunity loss and CVaR of opportunity loss. It is proven that the newsvendor’s optimal order quantity is related to the density function of market demand when the newsvendor exhibits risk-averse preference, which is inconsistent with the results in Schweitzer and Cachon (2000. The numerical example shows that the optimal order quantity that minimizes CVaR of opportunity loss is bigger than expected profit maximization (EPM order quantity for high-profit products and smaller than EPM order quantity for low-profit products, which is different from the experimental results in Schweitzer and Cachon (2000. A sensitivity analysis of changing the operation parameters of the two optimal order quantities is discussed. Our results confirm that high return implies high risk, while low risk comes with low return. Based on the results, some managerial insights are suggested for the risk management of the newsvendor model with backordering.

  20. Low doses - A real problem for radiation protection and radiobiology or a semantic crossword

    International Nuclear Information System (INIS)

    Vasilev, G.; Bayrakova, A.; Hadjieva, T.; Ingilizova, K.; Roupova, I.

    1997-01-01

    The ranges of small doses should be more accurately defined and differentiated. The linear non threshold conception is of an ethical character. Collective doses should not be used for assessment and limiting or risk without restrictions in the case of minimal doses. Recording of all kind of exposures is important, not just the occupational one. The hormesis and mutagenesis in small doses range do not exclude each other. They are parallel effects. (author)

  1. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  2. An environmental dose experiment

    Science.gov (United States)

    Peralta, Luis

    2017-11-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained.

  3. An environmental dose experiment

    International Nuclear Information System (INIS)

    Peralta, Luis

    2017-01-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained. (paper)

  4. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  5. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  6. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  7. Probabilistic Properties of Rectilinear Steiner Minimal Trees

    Directory of Open Access Journals (Sweden)

    V. N. Salnikov

    2015-01-01

    Full Text Available This work concerns the properties of Steiner minimal trees for the manhattan plane in the context of introducing a probability measure. This problem is important because exact algorithms to solve the Steiner problem are computationally expensive (NP-hard and the solution (especially in the case of big number of points to be connected has a diversity of practical applications. That is why the work considers a possibility to rank the possible topologies of the minimal trees with respect to a probability of their usage. For this, the known facts about the structural properties of minimal trees for selected metrics have been analyzed to see their usefulness for the problem in question. For the small amount of boundary (fixed vertices, the paper offers a way to introduce a probability measure as a corollary of proved theorem about some structural properties of the minimal trees.This work is considered to further the previous similar activity concerning a problem of searching for minimal fillings, and it is a door opener to the more general (complicated task. The stated method demonstrates the possibility to reach the final result analytically, which gives a chance of its applicability to the case of the bigger number of boundary vertices (probably, with the use of computer engineering.The introducing definition of an essential Steiner point allowed a considerable restriction of the ambiguity of initial problem solution and, at the same time, comparison of such an approach with more classical works in the field concerned. The paper also lists main barriers of classical approaches, preventing their use for the task of introducing a probability measure.In prospect, application areas of the described method are expected to be wider both in terms of system enlargement (the number of boundary vertices and in terms of other metric spaces (the Euclidean case is of especial interest. The main interest is to find the classes of topologies with significantly

  8. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  9. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    International Nuclear Information System (INIS)

    Lee, J; Chung, J

    2015-01-01

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy

  10. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  11. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  12. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  13. Internal dose estimates

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1977-01-01

    Internal doses, the procedures for making them and their significance has been reviewed. Effects of uranium, radium, lead-210, polonium-210, thorium in man are analysed based on data from tables and plots. Dosimetry of some ingested nuclides and inhalation dose due to radon-222, radon-220 and their daugther products are discussed [pt

  14. Transfer closed and transfer open multimaps in minimal spaces

    International Nuclear Information System (INIS)

    Alimohammady, M.; Roohi, M.; Delavar, M.R.

    2009-01-01

    This paper is devoted to introduce the concepts of transfer closed and transfer open multimaps in minimal spaces. Also, some characterizations of them are considered. Further, the notion of minimal local intersection property will be introduced and characterized. Moreover, some maximal element theorems via minimal transfer closed multimaps and minimal local intersection property are given.

  15. Occupational dose constraint

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle; Xavier, Ana Maria

    2005-01-01

    The revision process of the international radiological protection regulations has resulted in the adoption of new concepts, such as practice, intervention, avoidable and restriction of dose (dose constraint). The latter deserving of special mention since it may involve reducing a priori of the dose limits established both for the public and to individuals occupationally exposed, values that can be further reduced, depending on the application of the principle of optimization. This article aims to present, with clarity, from the criteria adopted to define dose constraint values to the public, a methodology to establish the dose constraint values for occupationally exposed individuals, as well as an example of the application of this methodology to the practice of industrial radiography

  16. Management of pediatric radiation dose using GE fluoroscopic equipment

    International Nuclear Information System (INIS)

    Belanger, Barry; Boudry, John

    2006-01-01

    In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an

  17. Fusion algebras of logarithmic minimal models

    International Nuclear Information System (INIS)

    Rasmussen, Joergen; Pearce, Paul A

    2007-01-01

    We present explicit conjectures for the chiral fusion algebras of the logarithmic minimal models LM(p,p') considering Virasoro representations with no enlarged or extended symmetry algebra. The generators of fusion are countably infinite in number but the ensuing fusion rules are quasi-rational in the sense that the fusion of a finite number of representations decomposes into a finite direct sum of representations. The fusion rules are commutative, associative and exhibit an sl(2) structure but require so-called Kac representations which are typically reducible yet indecomposable representations of rank 1. In particular, the identity of the fundamental fusion algebra p ≠ 1 is a reducible yet indecomposable Kac representation of rank 1. We make detailed comparisons of our fusion rules with the results of Gaberdiel and Kausch for p = 1 and with Eberle and Flohr for (p, p') = (2, 5) corresponding to the logarithmic Yang-Lee model. In the latter case, we confirm the appearance of indecomposable representations of rank 3. We also find that closure of a fundamental fusion algebra is achieved without the introduction of indecomposable representations of rank higher than 3. The conjectured fusion rules are supported, within our lattice approach, by extensive numerical studies of the associated integrable lattice models. Details of our lattice findings and numerical results will be presented elsewhere. The agreement of our fusion rules with the previous fusion rules lends considerable support for the identification of the logarithmic minimal models LM(p,p') with the augmented c p,p' (minimal) models defined algebraically

  18. How changes in a radiologist's technique can reduce patient dose in barium enema studies

    International Nuclear Information System (INIS)

    Corbett, R.H.

    2001-01-01

    Changes in a radiologist's technique, especially utilising digital technology, can lead to substantial dose savings in barium enema examinations. Data will be provided showing a 20% saving with only minimal change in technique. (author)

  19. Definitions of minimal flavour violation for leptons

    International Nuclear Information System (INIS)

    Palorini, F.

    2006-01-01

    Neutrino masses imply the violation of lepton flavour and new physics beyond the Standard Model. However, flavour change has only been observed in oscillations. In analogy with the quark sector, we could deduce the existence of a principle of Minimal Flavour Violation also for Leptons (MFVL). Such an extension is not straightforward, since the mechanisms generating neutrino masses are unknown and many scenarios can be envisaged. Thus, we explore some possible definitions of MFVL and propose a notion that can include many models. We show, furthermore, that flavour violating processes are not necessarily controlled by the PMNS mixing matrix. (author)

  20. Minimizing hydride cracking in zirconium alloys

    International Nuclear Information System (INIS)

    Coleman, C.E.; Cheadle, B.A.; Ambler, J.F.R.; Eadie, R.L.

    1985-01-01

    Zirconium alloy components can fail by hydride cracking if they contain large flaws and are highly stressed. If cracking in such components is suspected, crack growth can be minimized by following two simple operating rules: components should be heated up from at least 30K below any operating temperature above 450K, and when the component requires cooling to room temperature from a high temperature, any tensile stress should be reduced as much and as quickly as is practical during cooling. This paper describes the physical basis for these rules

  1. From topological strings to minimal models

    International Nuclear Information System (INIS)

    Foda, Omar; Wu, Jian-Feng

    2015-01-01

    We glue four refined topological vertices to obtain the building block of 5D U(2) quiver instanton partition functions. We take the 4D limit of the result to obtain the building block of 4D instanton partition functions which, using the AGT correspondence, are identified with Virasoro conformal blocks. We show that there is a choice of the parameters of the topological vertices that we start with, as well as the parameters and the intermediate states involved in the gluing procedure, such that we obtain Virasoro minimal model conformal blocks.

  2. From topological strings to minimal models

    Energy Technology Data Exchange (ETDEWEB)

    Foda, Omar [School of Mathematics and Statistics, University of Melbourne,Royal Parade, Parkville, VIC 3010 (Australia); Wu, Jian-Feng [Department of Mathematics and Statistics, Henan University,Minglun Street, Kaifeng city, Henan (China); Beijing Institute of Theoretical Physics and Mathematics,3rd Shangdi Street, Beijing (China)

    2015-07-24

    We glue four refined topological vertices to obtain the building block of 5D U(2) quiver instanton partition functions. We take the 4D limit of the result to obtain the building block of 4D instanton partition functions which, using the AGT correspondence, are identified with Virasoro conformal blocks. We show that there is a choice of the parameters of the topological vertices that we start with, as well as the parameters and the intermediate states involved in the gluing procedure, such that we obtain Virasoro minimal model conformal blocks.

  3. Minimally invasive surgery for esophageal achalasia.

    Science.gov (United States)

    Chen, Huan-Wen; Du, Ming

    2016-07-01

    Esophageal achalasia is due to the esophagus of neuromuscular dysfunction caused by esophageal functional disease. Its main feature is the lack of esophageal peristalsis, the lower esophageal sphincter pressure and to reduce the swallow's relaxation response. Lower esophageal muscular dissection is one of the main ways to treat esophageal achalasia. At present, the period of muscular layer under the thoracoscope esophagus dissection is one of the treatment of esophageal achalasia. Combined with our experience in minimally invasive esophageal surgery, to improved incision and operation procedure, and adopts the model of the complete period of muscular layer under the thoracoscope esophagus dissection in the treatment of esophageal achalasia.

  4. Minimization of PWR reactor control rods wear

    International Nuclear Information System (INIS)

    Ponzoni Filho, Pedro; Moura Angelkorte, Gunther de

    1995-01-01

    The Rod Cluster Control Assemblies (RCCA's) of Pressurized Water Reactors (PWR's) have experienced a continuously wall cladding wear when Reactor Coolant Pumps (RCP's) are running. Fretting wear is a result of vibrational contact between RCCA rodlets and the guide cards which provide lateral support for the rodlets when RCCA's are withdrawn from the core. A procedure is developed to minimize the rodlets wear, by the shuffling and axial reposition of RCCA's every operating cycle. These shuffling and repositions are based on measurement of the rodlet cladding thickness of all RCCA's. (author). 3 refs, 2 figs, 2 tabs

  5. Periodical cicadas: A minimal automaton model

    Science.gov (United States)

    de O. Cardozo, Giovano; de A. M. M. Silvestre, Daniel; Colato, Alexandre

    2007-08-01

    The Magicicada spp. life cycles with its prime periods and highly synchronized emergence have defied reasonable scientific explanation since its discovery. During the last decade several models and explanations for this phenomenon appeared in the literature along with a great deal of discussion. Despite this considerable effort, there is no final conclusion about this long standing biological problem. Here, we construct a minimal automaton model without predation/parasitism which reproduces some of these aspects. Our results point towards competition between different strains with limited dispersal threshold as the main factor leading to the emergence of prime numbered life cycles.

  6. Ramanujan's identities, minimal surfaces and solitons

    Indian Academy of Sciences (India)

    In this paper, using some of Ramanujan's identites and the W–E representation of minimal surfaces, and the analogue for B–I solitons, we obtain non-trivial identities. (1) For ζ = ±1, ±i and belonging to a suitable domain in C,. Re ln. (. 1 + ζ2. 1 − ζ2. ) = ∞. ∑ k=1 ln. ⎛. ⎝. −Im ln. (. 1+ζ. 1−ζ. ) −. ( k − 1. 2. ) π. 2 Re tan−1(ζ ) −.

  7. Physically Embedded Minimal Self-Replicating Systems

    DEFF Research Database (Denmark)

    Fellermann, Harold

    Self-replication is a fundamental property of all living organisms, yet has only been accomplished to limited extend in manmade systems. This thesis is part of the ongoing research endeavor to bridge the two sides of this gap. In particular, we present simulation results of a minimal life...... for any model above the atomistic scale. This is achieved by deriving an alternative scaling procedure for interaction parameters in the model. We perform system-level simulations of the design which attempt to account for theoretical, and experimental knowledge, as well as results from other...

  8. Flocking with minimal cooperativity: the panic model.

    Science.gov (United States)

    Pilkiewicz, Kevin R; Eaves, Joel D

    2014-01-01

    We present a two-dimensional lattice model of self-propelled spins that can change direction only upon collision with another spin. We show that even with ballistic motion and minimal cooperativity, these spins display robust flocking behavior at nearly all densities, forming long bands of stripes. The structural transition in this system is not a thermodynamic phase transition, but it can still be characterized by an order parameter, and we demonstrate that if this parameter is studied as a dynamical variable rather than a steady-state observable, we can extract a detailed picture of how the flocking mechanism varies with density.

  9. Minimal model for spoof acoustoelastic surface states

    Directory of Open Access Journals (Sweden)

    J. Christensen

    2014-12-01

    Full Text Available Similar to textured perfect electric conductors for electromagnetic waves sustaining artificial or spoof surface plasmons we present an equivalent phenomena for the case of sound. Aided by a minimal model that is able to capture the complex wave interaction of elastic cavity modes and airborne sound radiation in perfect rigid panels, we construct designer acoustoelastic surface waves that are entirely controlled by the geometrical environment. Comparisons to results obtained by full-wave simulations confirm the feasibility of the model and we demonstrate illustrative examples such as resonant transmissions and waveguiding to show a few examples of many where spoof elastic surface waves are useful.

  10. Minimally invasive splenectomy: an update and review

    Science.gov (United States)

    Gamme, Gary; Birch, Daniel W.; Karmali, Shahzeer

    2013-01-01

    Laparoscopic splenectomy (LS) has become an established standard of care in the management of surgical diseases of the spleen. The present article is an update and review of current procedures and controversies regarding minimally invasive splenectomy. We review the indications and contraindications for LS as well as preoperative considerations. An individual assessment of the procedures and outcomes of multiport laparoscopic splenectomy, hand-assisted laparoscopic splenectomy, robotic splenectomy, natural orifice transluminal endoscopic splenectomy and single-port splenectomy is included. Furthermore, this review examines postoperative considerations after LS, including the postoperative course of uncomplicated patients, postoperative portal vein thrombosis, infections and malignancy. PMID:23883500

  11. Pediatric neuro MRI. Tricks to minimize sedation

    Energy Technology Data Exchange (ETDEWEB)

    Barkovich, Matthew J.; Desikan, Rahul S. [University of California, San Francisco, Department of Radiology and Diagnostic Imaging, San Francisco, CA (United States); Xu, Duan; Barkovich, A.J. [University of California, San Francisco, Department of Radiology and Diagnostic Imaging, San Francisco, CA (United States); UCSF-Benioff Children' s Hospital, Department of Radiology, San Francisco, CA (United States); Williams, Cassandra [UCSF-Benioff Children' s Hospital, Department of Radiology, San Francisco, CA (United States)

    2018-01-15

    Magnetic resonance imaging (MRI) is the workhorse modality in pediatric neuroimaging because it provides excellent soft-tissue contrast without ionizing radiation. Until recently, studies were uninterpretable without sedation; however, given development of shorter sequences, sequences that correct for motion, and studies showing the potentially deleterious effects of sedation on immature laboratory animals, it is prudent to minimize sedation when possible. This manuscript provides basic guidelines for performing pediatric neuro MRI without sedation by both modifying technical factors to reduce scan time and noise, and using a multi-disciplinary team to coordinate imaging with the patient's biorhythms. (orig.)

  12. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  13. Minimally Invasive Spine Surgery in Small Animals.

    Science.gov (United States)

    Hettlich, Bianca F

    2018-01-01

    Minimally invasive spine surgery (MISS) seems to have many benefits for human patients and is currently used for various minor and major spine procedures. For MISS, a change in access strategy to the target location is necessary and it requires intraoperative imaging, special instrumentation, and magnification. Few veterinary studies have evaluated MISS for canine patients for spinal decompression procedures. This article discusses the general requirements for MISS and how these can be applied to veterinary spinal surgery. The current veterinary MISS literature is reviewed and suggestions are made on how to apply MISS to different spinal locations. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Smartphone-assisted minimally invasive neurosurgery.

    Science.gov (United States)

    Mandel, Mauricio; Petito, Carlo Emanuel; Tutihashi, Rafael; Paiva, Wellingson; Abramovicz Mandel, Suzana; Gomes Pinto, Fernando Campos; Ferreira de Andrade, Almir; Teixeira, Manoel Jacobsen; Figueiredo, Eberval Gadelha

    2018-03-13

    OBJECTIVE Advances in video and fiber optics since the 1990s have led to the development of several commercially available high-definition neuroendoscopes. This technological improvement, however, has been surpassed by the smartphone revolution. With the increasing integration of smartphone technology into medical care, the introduction of these high-quality computerized communication devices with built-in digital cameras offers new possibilities in neuroendoscopy. The aim of this study was to investigate the usefulness of smartphone-endoscope integration in performing different types of minimally invasive neurosurgery. METHODS The authors present a new surgical tool that integrates a smartphone with an endoscope by use of a specially designed adapter, thus eliminating the need for the video system customarily used for endoscopy. The authors used this novel combined system to perform minimally invasive surgery on patients with various neuropathological disorders, including cavernomas, cerebral aneurysms, hydrocephalus, subdural hematomas, contusional hematomas, and spontaneous intracerebral hematomas. RESULTS The new endoscopic system featuring smartphone-endoscope integration was used by the authors in the minimally invasive surgical treatment of 42 patients. All procedures were successfully performed, and no complications related to the use of the new method were observed. The quality of the images obtained with the smartphone was high enough to provide adequate information to the neurosurgeons, as smartphone cameras can record images in high definition or 4K resolution. Moreover, because the smartphone screen moves along with the endoscope, surgical mobility was enhanced with the use of this method, facilitating more intuitive use. In fact, this increased mobility was identified as the greatest benefit of the use of the smartphone-endoscope system compared with the use of the neuroendoscope with the standard video set. CONCLUSIONS Minimally invasive approaches

  15. Dose response relationship at low doses

    International Nuclear Information System (INIS)

    Schull, W.J.

    1992-01-01

    The data that have accrued in Hiroshima and Nagasaki on the effects of ionizing radiation on the developing human brain are reviewed. Effects considered are severe mental retardation, lowered IQ scores, decline in school performance, seizures, other neuropsychological effects, and small head size. All these factors may be related to radiation doses received by the mother during pregnancy. (L.L.) 3 figs., tab., 7 refs

  16. An absorbed dose calorimeter for IMRT dosimetry

    International Nuclear Information System (INIS)

    Duane, S.; Aldehaybes, M.; Bailey, M.; Lee, N.D.; Thomas, C.G.; Palmans, H.

    2012-01-01

    A new calorimeter for dosimetry in small and complex fields has been built. The device is intended for the direct determination of absorbed dose to water in moderately small fields and in composite fields such as IMRT treatments, and as a transfer instrument calibrated against existing absorbed dose standards in conventional reference conditions. The geometry, materials and mode of operation have been chosen to minimize detector perturbations when used in a water phantom, to give a reasonably isotropic response and to minimize the effects of heat transfer when the calorimeter is used in non-reference conditions in a water phantom. The size of the core is meant to meet the needs of measurement in IMRT treatments and is comparable to the size of the air cavity in a type NE2611 ionization chamber. The calorimeter may also be used for small field dosimetry. Initial measurements in reference conditions and in an IMRT head and neck plan, collapsed to gantry angle zero, have been made to estimate the thermal characteristics of the device, and to assess its performance in use. The standard deviation (estimated repeatability) of the reference absorbed dose measurements was 0.02 Gy (0.6%). (authors)

  17. Minimization of radioactive solid wastes from uranium mining and metallurgy

    International Nuclear Information System (INIS)

    Zhang Xueli; Xu Lechang; Wei Guangzhi; Gao Jie; Wang Erqi

    2010-01-01

    The concept and contents of radioactive waste minimization are introduced. The principle of radioactive waste minimization involving administration optimization, source reduction, recycling and reuse as well as volume reduction are discussed. The strategies and methods to minimize radioactive solid wastes from uranium mining and metallurgy are summarized. In addition, the benefit from its application of radioactive waste minimization is analyzed. Prospects for the research on radioactive so-lid waste minimization are made in the end. (authors)

  18. A study of different dose calculation methods and the impact on the dose evaluation protocol in lung stereotactic radiation therapy

    International Nuclear Information System (INIS)

    Takada, Takahiro; Furuya, Tomohisa; Ozawa, Shuichi; Ito, Kana; Kurokawa, Chie; Karasawa, Kumiko; Miura, Kohei

    2008-01-01

    AAA (analytical anisotropic algorithm) dose calculation, which shows a better performance for heterogeneity correction, was tested for lung stereotactic radiation therapy (SBRT) in comparison to conventional PBC (pencil beam convolution method) to evaluate its impact on tumor dose parameters. Eleven lung SBRT patients who were treated with photon 4 MV beams in our department between April 2003 and February 2007 were reviewed. Clinical target volume (CTV) was delineated including the spicula region on planning CT images. Planning target volume (PTV) was defined by adding the internal target volume (ITV) and set-up margin (SM) of 5 mm from CTV, and then an multileaf collimator (MLC) penumbra margin of another 5 mm was also added. Six-port non-coplanar beams were employed, and a total prescribed dose of 48 Gy was defined at the isocenter point with four fractions. The entire treatment for an individual patient was completed within 8 days. Under the same prescribed dose, calculated dose distribution, dose volume histogram (DVH), and tumor dose parameters were compared between two dose calculation methods. In addition, the fractionated prescription dose was repeatedly scaled until the monitor units (MUs) calculated by AAA reached a level of MUs nearly identical to those achieved by PBC. AAA resulted in significantly less D95 (irradiation dose that included 95% volume of PTV) and minimal dose in PTV compared to PBC. After rescaling of each MU for each beam in the AAA plan, there was no revision of the isocenter of the prescribed dose required. However, when the PTV volume was less than 20 cc, a 4% lower prescription resulted in nearly identical MUs between AAA and PBC. The prescribed dose in AAA should be the same as that in PBC, if the dose is administered at the isocenter point. However, planners should compare DVHs and dose distributions between AAA and PBC for a small lung tumor with a PTV volume less than approximately 20 cc. (author)

  19. Minimizing employee exposure to toxic chemical releases

    International Nuclear Information System (INIS)

    Plummer, R.W.; Stobbe, T.J.; Mogensen, J.E.; Jeram, L.K.

    1987-01-01

    This book describes procedures for minimizing employee exposure to toxic chemical releases and suggested personal protective equipment (PPE) to be used in the event of such chemical release. How individuals, employees, supervisors, or companies perceive the risks of chemical exposure (risk meaning both probability of exposure and effect of exposure) determines to a great extent what precautions are taken to avoid risk. In Part I, the authors develop and approach which divides the project into three phases: kinds of procedures currently being used; the types of toxic chemical release accidents and injuries that occur; and, finally, integration of this information into a set of recommended procedures which should decrease the likelihood of a toxic chemical release and, if one does occur, will minimize the exposure and its severity to employees. Part II covers the use of personal protective equipment. It addresses the questions: what personal protective equipment ensembles are used in industry in situations where the release of a toxic or dangerous chemical may occur or has occurred; and what personal protective equipment ensembles should be used in these situations

  20. Specialized minimal PDFs for optimized LHC calculations

    CERN Document Server

    Carrazza, Stefano; Kassabov, Zahari; Rojo, Juan

    2016-04-15

    We present a methodology for the construction of parton distribution functions (PDFs) designed to provide an accurate representation of PDF uncertainties for specific processes or classes of processes with a minimal number of PDF error sets: specialized minimal PDF sets, or SM-PDFs. We construct these SM-PDFs in such a way that sets corresponding to different input processes can be combined without losing information, specifically on their correlations, and that they are robust upon smooth variations of the kinematic cuts. The proposed strategy never discards information, so that the SM-PDF sets can be enlarged by the addition of new processes, until the prior PDF set is eventually recovered for a large enough set of processes. We illustrate the method by producing SM-PDFs tailored to Higgs, top quark pair, and electroweak gauge boson physics, and determine that, when the PDF4LHC15 combined set is used as the prior, around 11, 4 and 11 Hessian eigenvectors respectively are enough to fully describe the corresp...

  1. Minimization of heatwave morbidity and mortality.

    Science.gov (United States)

    Kravchenko, Julia; Abernethy, Amy P; Fawzy, Maria; Lyerly, H Kim

    2013-03-01

    Global climate change is projected to increase the frequency and duration of periods of extremely high temperatures. Both the general populace and public health authorities often underestimate the impact of high temperatures on human health. To highlight the vulnerable populations and illustrate approaches to minimization of health impacts of extreme heat, the authors reviewed the studies of heat-related morbidity and mortality for high-risk populations in the U.S. and Europe from 1958 to 2012. Heat exposure not only can cause heat exhaustion and heat stroke but also can exacerbate a wide range of medical conditions. Vulnerable populations, such as older adults; children; outdoor laborers; some racial and ethnic subgroups (particularly those with low SES); people with chronic diseases; and those who are socially or geographically isolated, have increased morbidity and mortality during extreme heat. In addition to ambient temperature, heat-related health hazards are exacerbated by air pollution, high humidity, and lack of air-conditioning. Consequently, a comprehensive approach to minimize the health effects of extreme heat is required and must address educating the public of the risks and optimizing heatwave response plans, which include improving access to environmentally controlled public havens, adaptation of social services to address the challenges required during extreme heat, and consistent monitoring of morbidity and mortality during periods of extreme temperatures. Copyright © 2013 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Minimally invasive thyroidectomy (MIT): indications and results.

    Science.gov (United States)

    Docimo, Giovanni; Salvatore Tolone, Salvatore; Gili, Simona; d'Alessandro, A; Casalino, G; Brusciano, L; Ruggiero, Roberto; Docimo, Ludovico

    2013-01-01

    To establish if the indication for different approaches for thyroidectomy and the incision length provided by means of pre-operative assessment of gland volume and size of nodules resulted in safe and effective outcomes and in any notable aesthetic or quality-of-life impact on patients. Ninehundred eightytwo consecutive patients, undergoing total thyroidectomy, were enrolled. The thyroid volume and maximal nodule diameter were measured by means of ultrasounds. Based on ultrasounds findings, patients were divided into three groups: minimally invasive video assisted thyroidectomy (MIVAT), minimally invasive thyroidectomy (MIT) and conventional thyroidectomy (CT) groups. The data concerning the following parameters were collected: operative time, postoperative complications, postoperative pain and cosmetic results. The MIVAT group included 179 patients, MIT group included 592 patients and CT group included 211 patients. Incidence of complications did not differ significantly in each group. In MIVAT and MIT group, the perception of postoperative pain was less intense than CT group. The patients in the MIVAT (7±1.5) and MIT (8±2) groups were more satisfied with the cosmetic results than those in CT group (5±1.3) (p= MIT is a technique totally reproducible, and easily convertible to perform surgical procedures in respect of the patient, without additional complications, increased costs, and with better aesthetic results.

  3. Navy Shipboard Hazardous Material Minimization Program

    Energy Technology Data Exchange (ETDEWEB)

    Bieberich, M.J. [Naval Surface Warfare Center, Annapolis, MD (United States). Carderock Div.; Robinson, P. [Life Cycle Engineering, Inc., Charleston, SC (United States); Chastain, B.

    1994-12-31

    The use of hazardous (and potentially hazardous) materials in shipboard cleaning applications has proliferated as new systems and equipments have entered the fleet to reside alongside existing equipments. With the growing environmental awareness (and additional, more restrictive regulations) at all levels/echelon commands of the DoD, the Navy has initiated a proactive program to undertake the minimization/elimination of these hazardous materials in order to eliminate HMs at the source. This paper will focus on the current Shipboard Hazardous Materials Minimization Program initiatives including the identification of authorized HM currently used onboard, identification of potential substitute materials for HM replacement, identification of new cleaning technologies and processes/procedures, and identification of technical documents which will require revision to eliminate the procurement of HMs into the federal supply system. Also discussed will be the anticipated path required to implement the changes into the fleet and automated decision processes (substitution algorithm) currently employed. The paper will also present the most recent technologies identified for approval or additional testing and analysis including: supercritical CO{sub 2} cleaning, high pressure blasting (H{sub 2}O + baking soda), aqueous and semi-aqueous cleaning materials and processes, solvent replacements and dedicated parts washing systems with internal filtering capabilities, automated software for solvent/cleaning process substitute selection. Along with these technological advances, data availability (from on-line databases and CDROM Database libraries) will be identified and discussed.

  4. PAO mud boosts ROP, minimizes enviro impact

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    A North Sea well drilled with a drilling fluid based on polyalphaolefin (PAO) chemistry has helped increase penetration rates and reduce torque and drag while minimizing environmental impact, according to a paper presented at the 1993 SPE/IADC Drilling Conference in Amsterdam. The paper, ''Superior Performance with Minimal Environmental Impact: A Novel Non-Aqueous Drilling Fluid'' (SPE/IADC 25753), written by J.E. Friedheim and R. Pantermuehl of M-I Drilling Fluids, says the rate of penetration was some 15% higher than in offset wells drilled with mineral-oil-base mud. Average penetration rates at the beginning of the 8,856-ft (2,700-m) 12 1/4-in. interval drilled exceeded 100 ft/hr (30.5 m/hr) and averaged higher than 90 ft/hr (27.4 m/hr) for the entire section. The authors attributed the performance to better hole cleaning. Hole cleaning, lubricity, inhibition and equivalent bottom-hole density were primary concerns while drilling the well. ''Environmental aspects of the PAO fluid show that it should be essentially non-toxic to aquatic life,'' the authors contended. ''Various toxicity, bioaccumulation and biodegradation work indicate that the PAO mud will have little impact on the environment while slowly biodegrading.''

  5. The minimal curvaton-Higgs model

    Energy Technology Data Exchange (ETDEWEB)

    Enqvist, Kari [Helsinki Univ. and Helsinki Institute of Physics (Finland). Physics Dept.; Lerner, Rose N. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Helsinki Univ. and Helsinki Institute of Physics (Finland). Physics Dept.; Takahashi, Tomo [Saga Univ. (Japan). Dept. of Physics

    2013-10-15

    We present the first full study of the minimal curvaton-Higgs (MCH) model, which is a minimal interpretation of the curvaton scenario with one real scalar coupled to the standard model Higgs boson. The standard model coupling allows the dynamics of the model to be determined in detail, including effects from the thermal background and from radiative corrections to the potential. The relevant mechanisms for curvaton decay are incomplete non-perturbative decay (delayed by thermal blocking), followed by decay via a dimension-5 non-renormalisable operator. To avoid spoiling the predictions of big bang nucleosynthesis, we find the ''bare'' curvaton mass to be m{sub {sigma}}{>=}8 x 10{sup 4} GeV. To match observational data from Planck there is an upper limit on the curvaton-higgs coupling g, between 10{sup -3} and 10{sup -2}, depending on the mass. This is due to interactions with the thermal background. We find that typically non-Gaussianities are small but that if f{sub NL} is observed in the near future then m{sub {sigma}}

  6. Minimally invasive brow suspension for facial paralysis.

    Science.gov (United States)

    Costantino, Peter D; Hiltzik, David H; Moche, Jason; Preminger, Aviva

    2003-01-01

    To report a new technique for unilateral brow suspension for facial paralysis that is minimally invasive, limits supraciliary scar formation, does not require specialized endoscopic equipment or expertise, and has proved to be equal to direct brow suspension in durability and symmetry. Retrospective survey of a case series of 23 patients between January 1997 and December 2000. Metropolitan tertiary care center. Patients with head and neck tumors and brow ptosis caused by facial nerve paralysis. The results of the procedure were determined using the following 3-tier rating system: outstanding (excellent elevation and symmetry); acceptable (good elevation and fair symmetry); and unacceptable (loss of elevation). The results were considered outstanding in 12 patients, acceptable in 9 patients, and unacceptable in only 1 patient. One patient developed a hematoma, and 1 patient required a secondary adjustment. The technique has proved to be superior to standard brow suspension procedures with regard to scar formation and equal with respect to facial symmetry and suspension. These results have caused us to abandon direct brow suspension and to use this minimally invasive method in all cases of brow ptosis due to facial paralysis.

  7. [Theory and practice of minimally invasive endodontics].

    Science.gov (United States)

    Jiang, H W

    2016-08-01

    The primary goal of modern endodontic therapy is to achieve the long-term retention of a functional tooth by preventing or treating pulpitis or apical periodontitis is. The long-term retention of endodontically treated tooth is correlated with the remaining amount of tooth tissue and the quality of the restoration after root canal filling. In recent years, there has been rapid progress and development in the basic research of endodontic biology, instrument and applied materials, making treatment procedures safer, more accurate, and more efficient. Thus, minimally invasive endodontics(MIE)has received increasing attention at present. MIE aims to preserve the maximum of tooth structure during root canal therapy, and the concept covers the whole process of diagnosis and treatment of teeth. This review article focuses on describing the minimally invasive concepts and operating essentials in endodontics, from diagnosis and treatment planning to the access opening, pulp cavity finishing, root canal cleaning and shaping, 3-dimensional root canal filling and restoration after root canal treatment.

  8. Minimal size of a barchan dune

    Science.gov (United States)

    Parteli, E. J. R.; Durán, O.; Herrmann, H. J.

    2007-01-01

    Barchans are dunes of high mobility which have a crescent shape and propagate under conditions of unidirectional wind. However, sand dunes only appear above a critical size, which scales with the saturation distance of the sand flux [P. Hersen, S. Douady, and B. Andreotti, Phys. Rev. Lett. 89, 264301 (2002); B. Andreotti, P. Claudin, and S. Douady, Eur. Phys. J. B 28, 321 (2002); G. Sauermann, K. Kroy, and H. J. Herrmann, Phys. Rev. E 64, 31305 (2001)]. It has been suggested by P. Hersen, S. Douady, and B. Andreotti, Phys. Rev. Lett. 89, 264301 (2002)] that this flux fetch distance is itself constant. Indeed, this could not explain the protosize of barchan dunes, which often occur in coastal areas of high litoral drift, and the scale of dunes on Mars. In the present work, we show from three-dimensional calculations of sand transport that the size and the shape of the minimal barchan dune depend on the wind friction speed and the sand flux on the area between dunes in a field. Our results explain the common appearance of barchans a few tens of centimeter high which are observed along coasts. Furthermore, we find that the rate at which grains enter saltation on Mars is one order of magnitude higher than on Earth, and is relevant to correctly obtain the minimal dune size on Mars.

  9. Minimally invasive approach of panfacial fractures

    Directory of Open Access Journals (Sweden)

    Yudi Wijaya

    2017-08-01

    Full Text Available Background. Panfacial fractures involves fractures of several bones of face. They are associated with malocclusion, dish face deformity, enopthalmos, diplopia, cerebrospinal fluid leak and soft tissue injuries. Purpose. The purpose of this paper is to present a case of minimizing surgical wound and morbidity. Case. A 40 year old female presented with severe maxillofacial injuries caused by motor vehicle collisions about 5 days prior to admission. The assessment of the patient is mild head injury, panfacial fractures, lacerated wound at face,  rupture of globe of occular sinistra. An open reduction and internal fixation  (ORIF and enucleation of globe occular sinistra was performed.  Intraoral vestibular incision is made in the upper and lower vestibular region. Mucoperiosteal flap elevation of vestibular will exposure of the anterior maxilla and mandibular fractures. Intermaksilary fixation within 3 week and restore aesthetic with prosthesis fitting eyeball and denture. Discusion. The goal of  treatment of  panfacial fracture is to restore both the functions and pre-injury 3-dimensional facial contours. To achieve this goal two common  sequences of management of Panfacial fractures are proposed, “Bottom up and inside out” or “Top down and outside in”. Other sequences exist but there are variations of these two major approaches. Conclusion. A minimally invasive approach to  the fracture site is an alternative method  to manage panfacial fracture with a simple, effective and lower complication rate.

  10. Flavored dark matter beyond Minimal Flavor Violation

    CERN Document Server

    Agrawal, Prateek; Gemmler, Katrin

    2014-10-13

    We study the interplay of flavor and dark matter phenomenology for models of flavored dark matter interacting with quarks. We allow an arbitrary flavor structure in the coupling of dark matter with quarks. This coupling is assumed to be the only new source of violation of the Standard Model flavor symmetry extended by a $U(3)_\\chi$ associated with the dark matter. We call this ansatz Dark Minimal Flavor Violation (DMFV) and highlight its various implications, including an unbroken discrete symmetry that can stabilize the dark matter. As an illustration we study a Dirac fermionic dark matter $\\chi$ which transforms as triplet under $U(3)_\\chi$, and is a singlet under the Standard Model. The dark matter couples to right-handed down-type quarks via a colored scalar mediator $\\phi$ with a coupling $\\lambda$. We identify a number of "flavor-safe" scenarios for the structure of $\\lambda$ which are beyond Minimal Flavor Violation. For dark matter and collider phenomenology we focus on the well-motivated case of $b$-...

  11. Minimalism in architecture: Abstract conceptualization of architecture

    Directory of Open Access Journals (Sweden)

    Vasilski Dragana

    2015-01-01

    Full Text Available Minimalism in architecture contains the idea of the minimum as a leading creative tend to be considered and interpreted in working through phenomena of empathy and abstraction. In the Western culture, the root of this idea is found in empathy of Wilhelm Worringer and abstraction of Kasimir Malevich. In his dissertation, 'Abstraction and Empathy' Worringer presented his thesis on the psychology of style through which he explained the two opposing basic forms: abstraction and empathy. His conclusion on empathy as a psychological basis of observation expression is significant due to the verbal congruence with contemporary minimalist expression. His intuition was enhenced furthermore by figure of Malevich. Abstraction, as an expression of inner unfettered inspiration, has played a crucial role in the development of modern art and architecture of the twentieth century. Abstraction, which is one of the basic methods of learning in psychology (separating relevant from irrelevant features, Carl Jung is used to discover ideas. Minimalism in architecture emphasizes the level of abstraction to which the individual functions are reduced. Different types of abstraction are present: in the form as well as function of the basic elements: walls and windows. The case study is an example of Sou Fujimoto who is unequivocal in its commitment to the autonomy of abstract conceptualization of architecture.

  12. Specialized minimal PDFs for optimized LHC calculations

    International Nuclear Information System (INIS)

    Carrazza, Stefano; Forte, Stefano; Kassabov, Zahari; Rojo, Juan

    2016-01-01

    We present a methodology for the construction of parton distribution functions (PDFs) designed to provide an accurate representation of PDF uncertainties for specific processes or classes of processes with a minimal number of PDF error sets: specialized minimal PDF sets, or SM-PDFs. We construct these SM-PDFs in such a way that sets corresponding to different input processes can be combined without losing information, specifically as regards their correlations, and that they are robust upon smooth variations of the kinematic cuts. The proposed strategy never discards information, so that the SM-PDF sets can be enlarged by the addition of new processes, until the prior PDF set is eventually recovered for a large enough set of processes. We illustrate the method by producing SM-PDFs tailored to Higgs, top-quark pair, and electroweak gauge boson physics, and we determine that, when the PDF4LHC15 combined set is used as the prior, around 11, 4, and 11 Hessian eigenvectors, respectively, are enough to fully describe the corresponding processes. (orig.)

  13. Flavored dark matter beyond Minimal Flavor Violation

    International Nuclear Information System (INIS)

    Agrawal, Prateek; Blanke, Monika; Gemmler, Katrin

    2014-01-01

    We study the interplay of flavor and dark matter phenomenology for models of flavored dark matter interacting with quarks. We allow an arbitrary flavor structure in the coupling of dark matter with quarks. This coupling is assumed to be the only new source of violation of the Standard Model flavor symmetry extended by a U(3) χ associated with the dark matter. We call this ansatz Dark Minimal Flavor Violation (DMFV) and highlight its various implications, including an unbroken discrete symmetry that can stabilize the dark matter. As an illustration we study a Dirac fermionic dark matter χ which transforms as triplet under U(3) χ , and is a singlet under the Standard Model. The dark matter couples to right-handed down-type quarks via a colored scalar mediator with a coupling. We identify a number of ''flavor-safe'' scenarios for the structure of which are beyond Minimal Flavor Violation. Also, for dark matter and collider phenomenology we focus on the well-motivated case of b-flavored dark matter. Furthermore, the combined flavor and dark matter constraints on the parameter space of turn out to be interesting intersections of the individual ones. LHC constraints on simplified models of squarks and sbottoms can be adapted to our case, and monojet searches can be relevant if the spectrum is compressed

  14. Thymoma and minimally invasive surgical treatment

    International Nuclear Information System (INIS)

    Krajc, T.; Spalek, P.; Lucenic, M.; Benej, R.; Harustiak, S.

    2011-01-01

    The authors review the current thymoma classification schemes, diagnosis and surgical treatment options. Many minimally invasive techniques do not provide sufficient extensiveness when compared to complete sternotomy. The Zieliński technique combines transcervical, subxiphoidal and bilateral thoracoscopic approach in a hybrid procedure (MMIT, maximal minimally invasive thymectomy) based on double sternal traction, and allows for removal of the thymus gland, the thymoma and all the relevant mediastinal adipose tissue, thus adhering to principles of oncological radicality. Of the 28 patients undergoing MMIT there were 7 with myasthenia associated thymoma (MGAT) and 5 with a thymoma and no myasthenia, tumors staged Masaoka I-II. Apart from one temporary recurrent nerve palsy there were no postoperative complications. The largest thymoma measured 70 x 65 x 55 mm. Adjuvant radiotherapy was applied in 5 patients. Ectopic thymic tissue was identified in 100 % of patients with thymoma and no myasthenia and in 42.9 % of MGAT patients. Until now there were no recurrences, however, the follow-up median is very short, the longest follow-up period being 30 months. MMIT is a safe technique suitable also for Masaoka I-II thymoma patients and for some specific cases with Masaoka III stage (lung parenchyma invasion). The authors approach all the anterior mediastinal tumors with no mediastinal lymphadenopathy and no myasthenia as a potential thymoma and always attempt the MMIT procedure starting as VATS procedure on the side of tumor. (author)

  15. Power Minimization techniques for Networked Data Centers

    International Nuclear Information System (INIS)

    Low, Steven; Tang, Kevin

    2011-01-01

    Our objective is to develop a mathematical model to optimize energy consumption at multiple levels in networked data centers, and develop abstract algorithms to optimize not only individual servers, but also coordinate the energy consumption of clusters of servers within a data center and across geographically distributed data centers to minimize the overall energy cost and consumption of brown energy of an enterprise. In this project, we have formulated a variety of optimization models, some stochastic others deterministic, and have obtained a variety of qualitative results on the structural properties, robustness, and scalability of the optimal policies. We have also systematically derived from these models decentralized algorithms to optimize energy efficiency, analyzed their optimality and stability properties. Finally, we have conducted preliminary numerical simulations to illustrate the behavior of these algorithms. We draw the following conclusion. First, there is a substantial opportunity to minimize both the amount and the cost of electricity consumption in a network of datacenters, by exploiting the fact that traffic load, electricity cost, and availability of renewable generation fluctuate over time and across geographical locations. Judiciously matching these stochastic processes can optimize the tradeoff between brown energy consumption, electricity cost, and response time. Second, given the stochastic nature of these three processes, real-time dynamic feedback should form the core of any optimization strategy. The key is to develop decentralized algorithms that can be implemented at different parts of the network as simple, local algorithms that coordinate through asynchronous message passing.

  16. The minimal curvaton-Higgs model

    International Nuclear Information System (INIS)

    Enqvist, Kari; Lerner, Rose N.; Helsinki Univ. and Helsinki Institute of Physics; Takahashi, Tomo

    2013-10-01

    We present the first full study of the minimal curvaton-Higgs (MCH) model, which is a minimal interpretation of the curvaton scenario with one real scalar coupled to the standard model Higgs boson. The standard model coupling allows the dynamics of the model to be determined in detail, including effects from the thermal background and from radiative corrections to the potential. The relevant mechanisms for curvaton decay are incomplete non-perturbative decay (delayed by thermal blocking), followed by decay via a dimension-5 non-renormalisable operator. To avoid spoiling the predictions of big bang nucleosynthesis, we find the ''bare'' curvaton mass to be m σ ≥8 x 10 4 GeV. To match observational data from Planck there is an upper limit on the curvaton-higgs coupling g, between 10 -3 and 10 -2 , depending on the mass. This is due to interactions with the thermal background. We find that typically non-Gaussianities are small but that if f NL is observed in the near future then m σ 9 GeV, depending on Hubble scale during inflation. In a thermal dark matter model, the lower bound on m σ can increase substantially. The parameter space may also be affected once the baryogenesis mechanism is specified.

  17. Synchronized dynamic dose reconstruction

    International Nuclear Information System (INIS)

    Litzenberg, Dale W.; Hadley, Scott W.; Tyagi, Neelam; Balter, James M.; Ten Haken, Randall K.; Chetty, Indrin J.

    2007-01-01

    Variations in target volume position between and during treatment fractions can lead to measurable differences in the dose distribution delivered to each patient. Current methods to estimate the ongoing cumulative delivered dose distribution make idealized assumptions about individual patient motion based on average motions observed in a population of patients. In the delivery of intensity modulated radiation therapy (IMRT) with a multi-leaf collimator (MLC), errors are introduced in both the implementation and delivery processes. In addition, target motion and MLC motion can lead to dosimetric errors from interplay effects. All of these effects may be of clinical importance. Here we present a method to compute delivered dose distributions for each treatment beam and fraction, which explicitly incorporates synchronized real-time patient motion data and real-time fluence and machine configuration data. This synchronized dynamic dose reconstruction method properly accounts for the two primary classes of errors that arise from delivering IMRT with an MLC: (a) Interplay errors between target volume motion and MLC motion, and (b) Implementation errors, such as dropped segments, dose over/under shoot, faulty leaf motors, tongue-and-groove effect, rounded leaf ends, and communications delays. These reconstructed dose fractions can then be combined to produce high-quality determinations of the dose distribution actually received to date, from which individualized adaptive treatment strategies can be determined

  18. Low-dose vaporized cannabis significantly improves neuropathic pain.

    Science.gov (United States)

    Wilsey, Barth; Marcotte, Thomas; Deutsch, Reena; Gouaux, Ben; Sakai, Staci; Donaghe, Haylee

    2013-02-01

    We conducted a double-blind, placebo-controlled, crossover study evaluating the analgesic efficacy of vaporized cannabis in subjects, the majority of whom were experiencing neuropathic pain despite traditional treatment. Thirty-nine patients with central and peripheral neuropathic pain underwent a standardized procedure for inhaling medium-dose (3.53%), low-dose (1.29%), or placebo cannabis with the primary outcome being visual analog scale pain intensity. Psychoactive side effects and neuropsychological performance were also evaluated. Mixed-effects regression models demonstrated an analgesic response to vaporized cannabis. There was no significant difference between the 2 active dose groups' results (P > .7). The number needed to treat (NNT) to achieve 30% pain reduction was 3.2 for placebo versus low-dose, 2.9 for placebo versus medium-dose, and 25 for medium- versus low-dose. As these NNTs are comparable to those of traditional neuropathic pain medications, cannabis has analgesic efficacy with the low dose being as effective a pain reliever as the medium dose. Psychoactive effects were minimal and well tolerated, and neuropsychological effects were of limited duration and readily reversible within 1 to 2 hours. Vaporized cannabis, even at low doses, may present an effective option for patients with treatment-resistant neuropathic pain. The analgesia obtained from a low dose of delta-9-tetrahydrocannabinol (1.29%) in patients, most of whom were experiencing neuropathic pain despite conventional treatments, is a clinically significant outcome. In general, the effect sizes on cognitive testing were consistent with this minimal dose. As a result, one might not anticipate a significant impact on daily functioning. Published by Elsevier Inc.

  19. MOCUS, Minimal Cut Sets and Minimal Path Sets from Fault Tree Analysis

    International Nuclear Information System (INIS)

    Fussell, J.B.; Henry, E.B.; Marshall, N.H.

    1976-01-01

    1 - Description of problem or function: From a description of the Boolean failure logic of a system, called a fault tree, and control parameters specifying the minimal cut set length to be obtained MOCUS determines the system failure modes, or minimal cut sets, and the system success modes, or minimal path sets. 2 - Method of solution: MOCUS uses direct resolution of the fault tree into the cut and path sets. The algorithm used starts with the main failure of interest, the top event, and proceeds to basic independent component failures, called primary events, to resolve the fault tree to obtain the minimal sets. A key point of the algorithm is that an and gate alone always increases the number of path sets; an or gate alone always increases the number of cut sets and increases the size of path sets. Other types of logic gates must be described in terms of and and or logic gates. 3 - Restrictions on the complexity of the problem: Output from MOCUS can include minimal cut and path sets for up to 20 gates

  20. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  1. Minimal and non-minimal standard models: Universality of radiative corrections

    International Nuclear Information System (INIS)

    Passarino, G.

    1991-01-01

    The possibility of describing electroweak processes by means of models with a non-minimal Higgs sector is analyzed. The renormalization procedure which leads to a set of fitting equations for the bare parameters of the lagrangian is first reviewed for the minimal standard model. A solution of the fitting equations is obtained, which correctly includes large higher-order corrections. Predictions for physical observables, notably the W boson mass and the Z O partial widths, are discussed in detail. Finally the extension to non-minimal models is described under the assumption that new physics will appear only inside the vector boson self-energies and the concept of universality of radiative corrections is introduced, showing that to a large extent they are insensitive to the details of the enlarged Higgs sector. Consequences for the bounds on the top quark mass are also discussed. (orig.)

  2. Minimizing material damage using low temperature irradiation

    International Nuclear Information System (INIS)

    Craven, E.; Hasanain, F.; Winters, M.

    2012-01-01

    Scientific advancements in healthcare driven both by technological breakthroughs and an aging and increasingly obese population have lead to a changing medical device market. Complex products and devices are being developed to meet the demands of leading edge medical procedures. Specialized materials in these medical devices, including pharmaceuticals and biologics as well as exotic polymers present a challenge for radiation sterilization as many of these components cannot withstand conventional irradiation methods. The irradiation of materials at dry ice temperatures has emerged as a technique that can be used to decrease the radiation sensitivity of materials. The purpose of this study is to examine the effect of low temperature irradiation on a variety of polymer materials, and over a range of temperatures from 0 °C down to −80 °C. The effectiveness of microbial kill is also investigated under each of these conditions. The results of the study show that the effect of low temperature irradiation is material dependent and can alter the balance between crosslinking and chain scission of the polymer. Low temperatures also increase the dose required to achieve an equivalent microbiological kill, therefore dose setting exercises must be performed under the environmental conditions of use. - Highlights: ► A study is performed to quantify low temperature irradiation effects on polymer materials and BIs. ► Low temperature irradiation alters the balance of cross-linking and chain scissoning in polymers. ► Low temperatures provide radioprotection for BIs. ► Benefits of low temperatures are application specific and must be considered when dose setting.

  3. Modifying gummy smile: a minimally invasive approach.

    Science.gov (United States)

    Abdullah, Walid Ahmed; Khalil, Hesham S; Alhindi, Maryam M; Marzook, Hamdy

    2014-11-01

    Excessive gingival display is a problem that can be managed by variety of procedures. These procedures include non-surgical and surgical methods. The underlying cause of gummy smile can affect the type of procedure to be selected. Most patients prefer minimally invasive procedures with outstanding results. The authors describe a minimally invasive lip repositioning technique for management of gummy smile. Twelve patients (10 females, 2 males) with gingival display of 4 mm or more were operated under local anesthesia using a modified lip repositioning technique. Patients were followed up for 1, 3, 6 and 12 months and gingival display was measured at each follow up visit. The gingival mucosa was dissected and levator labii superioris and depressor septi muscles were freed and repositioned in a lower position. The levator labii superioris muscles were pulled in a lower position using circumdental sutures for 10 days. Both surgeon's and patient's satisfaction of surgical outcome was recorded at each follow-up visit. At early stage of follow-up the main complaints of patients were the feeling of tension in the upper lip and circum oral area, mild pain which was managed with analgesics. One month postoperatively, the gingival display in all patients was recorded to be between 2 and 4 mm with a mean of (2.6 mm). Patient satisfaction records after 1 month showed that 10 patients were satisfied with the results. Three months postoperatively, the gingival display in all patients was recorded and found to be between 2 and 5 mm with a mean of 3 mm. Patient satisfaction records showed that 8 patients were satisfied with the results as they gave scores between. Surgeon's satisfaction at three months follow up showed that the surgeons were satisfied in 8 patients. The same results were found in the 6 and 12 months follow-up periods without any changes. Complete relapse was recorded only in one case at the third postoperative month. This study showed that the proposed lip

  4. Minimizing water consumption when producing hydropower

    Science.gov (United States)

    Leon, A. S.

    2015-12-01

    In 2007, hydropower accounted for only 16% of the world electricity production, with other renewable sources totaling 3%. Thus, it is not surprising that when alternatives are evaluated for new energy developments, there is strong impulse for fossil fuel or nuclear energy as opposed to renewable sources. However, as hydropower schemes are often part of a multipurpose water resources development project, they can often help to finance other components of the project. In addition, hydropower systems and their associated dams and reservoirs provide human well-being benefits, such as flood control and irrigation, and societal benefits such as increased recreational activities and improved navigation. Furthermore, hydropower due to its associated reservoir storage, can provide flexibility and reliability for energy production in integrated energy systems. The storage capability of hydropower systems act as a regulating mechanism by which other intermittent and variable renewable energy sources (wind, wave, solar) can play a larger role in providing electricity of commercial quality. Minimizing water consumption for producing hydropower is critical given that overuse of water for energy production may result in a shortage of water for other purposes such as irrigation, navigation or fish passage. This paper presents a dimensional analysis for finding optimal flow discharge and optimal penstock diameter when designing impulse and reaction water turbines for hydropower systems. The objective of this analysis is to provide general insights for minimizing water consumption when producing hydropower. This analysis is based on the geometric and hydraulic characteristics of the penstock, the total hydraulic head and the desired power production. As part of this analysis, various dimensionless relationships between power production, flow discharge and head losses were derived. These relationships were used to withdraw general insights on determining optimal flow discharge and

  5. Doses from radioactive methane

    International Nuclear Information System (INIS)

    Phipps, A.W.; Kendall, G.M.; Fell, T.P.; Harrison, J.D.

    1990-01-01

    A possible radiation hazard arises from exposure to methane labelled with either a 3 H or a 14 C nuclide. This radioactive methane could be released from a variety of sources, e.g. land burial sites containing radioactive waste. Standard assumptions adopted for vapours would not apply to an inert alkane like methane. This paper discusses mechanisms by which radioactive methane would irradiate tissues and provides estimates of doses. Data on skin thickness and metabolism of methane are discussed with reference to these mechanisms. It is found that doses are dominated by dose from the small fraction of methane which is inhaled and metabolised. This component of dose has been calculated under rather conservative assumptions. (author)

  6. Controllable dose; Dosis controlable

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T; Anaya M, R A [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2004-07-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  7. Acetaminophen dosing for children

    Science.gov (United States)

    ... your child, call your provider. Proper Dosing of Suppositories If your child is vomiting or will not take oral medicine, you can use suppositories. Suppositories are placed in the anus to deliver ...

  8. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  9. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  10. Maximum permissible dose

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed

  11. Irradiation dose of cosmonauts

    International Nuclear Information System (INIS)

    Makra, Zs.

    1978-01-01

    The results obtained by determining the irradiation dose during the spaceflights of Apollo as well as the Sojouz-3 and Sojouz-9 spacecrafts have been compared in the form of tables. In case of Apollo astronauts the irradiation dose was determined by two methods and its sources were also pointed out, in tables. During Sojouz spacetravels the cosmonauts were exposed to a negligible dose. In spite of this fact the radiation danger is considerable. The small irradiation doses noticed so far are due to the fact that during the spaceflights there was no big proturberance. However, during the future long-range spacetravels a better radiation shielding than the one used up to now will be necessary. (P.J.)

  12. Ibuprofen dosing for children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000772.htm Ibuprofen dosing for children To use the sharing features ... much of this medicine can be harmful. How Ibuprofen can Help Your Child Ibuprofen is a type ...

  13. Gamma radiation in the reduction of Salmonella spp. inoculated on minimally processed watercress (Nasturtium officinalis)

    International Nuclear Information System (INIS)

    Martins, C.G.; Behrens, J.H.; Destro, M.T.; Franco, B.D.G.M.; Vizeu, D.M.; Hutzler, B.; Landgraf, M.

    2004-01-01

    Consumer attitudes towards foods have changed in the last two decades increasing requirements for freshlike products. Consequently, less extreme treatments or additives are being required. Minimally processed foods have freshlike characteristics and satisfy this new consumer demand. Besides freshness, the minimally processing also provide convenience required by the market. Salad vegetables can be source of pathogen such as Salmonella, Escherichia coli O157:H7, Shigella spp. The minimal processing does not reduce the levels of pathogenic microorganisms to safe levels. Therefore, this study was carried out in order to improve the microbiological safety and the shelf-life of minimally processed vegetables using gamma radiation. Minimally processed watercress inoculated with a cocktail of Salmonella spp was exposed to 0.0, 0.2, 0.5, 0.7, 1.0, 1.2 and 1.5 kGy. Irradiated samples were diluted 1:10 in saline peptone water and plated onto tryptic soy agar that were incubated at 37 deg. C/24 h. D 10 values for Salmonella spp. inoculated in watercress varied from 0.29 to 0.43 kGy. Therefore, a dose of 1.7 kGy will reduce Salmonella population in watercress by 4 log 10 . The shelf-life was increased by 1 1/2 day when the product was exposed to 1 kGy

  14. Gamma radiation in the reduction of S almonella spp. inoculated on minimally processed watercress ( Nasturtium officinalis)

    Science.gov (United States)

    Martins, C. G.; Behrens, J. H.; Destro, M. T.; Franco, B. D. G. M.; Vizeu, D. M.; Hutzler, B.; Landgraf, M.

    2004-09-01

    Consumer attitudes towards foods have changed in the last two decades increasing requirements for freshlike products. Consequently, less extreme treatments or additives are being required. Minimally processed foods have freshlike characteristics and satisfy this new consumer demand. Besides freshness, the minimally processing also provide convenience required by the market. Salad vegetables can be source of pathogen such as Salmonella, Escherichia coli O157:H7, Shigella spp. The minimal processing does not reduce the levels of pathogenic microorganisms to safe levels. Therefore, this study was carried out in order to improve the microbiological safety and the shelf-life of minimally processed vegetables using gamma radiation. Minimally processed watercress inoculated with a cocktail of Salmonella spp was exposed to 0.0, 0.2, 0.5, 0.7, 1.0, 1.2 and 1.5 kGy. Irradiated samples were diluted 1:10 in saline peptone water and plated onto tryptic soy agar that were incubated at 37°C/24 h. D 10 values for Salmonella spp. inoculated in watercress varied from 0.29 to 0.43 kGy. Therefore, a dose of 1.7 kGy will reduce Salmonella population in watercress by 4 log 10. The shelf-life was increased by 1 {1}/{2} day when the product was exposed to 1 kGy.

  15. Gamma radiation in the reduction of Salmonella spp. inoculated on minimally processed watercress (Nasturtium officinalis)

    Energy Technology Data Exchange (ETDEWEB)

    Martins, C.G.; Behrens, J.H.; Destro, M.T.; Franco, B.D.G.M.; Vizeu, D.M.; Hutzler, B.; Landgraf, M. E-mail: landgraf@usp.br

    2004-10-01

    Consumer attitudes towards foods have changed in the last two decades increasing requirements for freshlike products. Consequently, less extreme treatments or additives are being required. Minimally processed foods have freshlike characteristics and satisfy this new consumer demand. Besides freshness, the minimally processing also provide convenience required by the market. Salad vegetables can be source of pathogen such as Salmonella, Escherichia coli O157:H7, Shigella spp. The minimal processing does not reduce the levels of pathogenic microorganisms to safe levels. Therefore, this study was carried out in order to improve the microbiological safety and the shelf-life of minimally processed vegetables using gamma radiation. Minimally processed watercress inoculated with a cocktail of Salmonella spp was exposed to 0.0, 0.2, 0.5, 0.7, 1.0, 1.2 and 1.5 kGy. Irradiated samples were diluted 1:10 in saline peptone water and plated onto tryptic soy agar that were incubated at 37 deg. C/24 h. D{sub 10} values for Salmonella spp. inoculated in watercress varied from 0.29 to 0.43 kGy. Therefore, a dose of 1.7 kGy will reduce Salmonella population in watercress by 4 log{sub 10}. The shelf-life was increased by 1 1/2 day when the product was exposed to 1 kGy.

  16. Minimal Residual Disease in Acute Myeloid Leukemia: Still a Work in Progress?

    Directory of Open Access Journals (Sweden)

    Federico Mosna

    2017-06-01

    Full Text Available Minimal residual disease evaluation refers to a series of molecular and immunophenotypical techniques aimed at detecting submicroscopic disease after therapy. As such, its application in acute myeloid leukemia has greatly increased our ability to quantify treatment response, and to determine the chemosensitivity of the disease, as the final product of the drug schedule, dose intensity, biodistribution, and the pharmakogenetic profile of the patient. There is now consistent evidence for the prognostic power of minimal residual disease evaluation in acute myeloid leukemia, which is complementary to the baseline prognostic assessment of the disease. The focus for its use is therefore shifting to individualize treatment based on a deeper evaluation of chemosensitivity and residual tumor burden. In this review, we will summarize the results of the major clinical studies evaluating minimal residual disease in acute myeloid leukemia in adults in recent years and address the technical and practical issues still hampering the spread of these techniques outside controlled clinical trials. We will also briefly speculate on future developments and offer our point of view, and a word of caution, on the present use of minimal residual disease measurements in “real-life” practice. Still, as final standardization and diffusion of the methods are sorted out, we believe that minimal residual disease will soon become the new standard for evaluating response in the treatment of acute myeloid leukemia.

  17. Quantization of the minimal and non-minimal vector field in curved space

    OpenAIRE

    Toms, David J.

    2015-01-01

    The local momentum space method is used to study the quantized massive vector field (the Proca field) with the possible addition of non-minimal terms. Heat kernel coefficients are calculated and used to evaluate the divergent part of the one-loop effective action. It is shown that the naive expression for the effective action that one would write down based on the minimal coupling case needs modification. We adopt a Faddeev-Jackiw method of quantization and consider the case of an ultrastatic...

  18. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  19. Gonadal doses from radiotherapy

    International Nuclear Information System (INIS)

    Solomon, S.B.; Morris, N.D.

    1980-06-01

    The method of calculation of gonadal doses arising from different radiotherapeutic procedures is described. The measurement of scatter factors to the gonads from superficial and deep therapy is detailed and the analytic fits to the experimental data, as a function of field position, field size and beam energy are given. The data used to calculate the gonadal doses from treatments using linear accelerators, teletherapy and sealed sources are described and the analytic fits to the data given

  20. Minimizing variability of cascade impaction measurements in inhalers and nebulizers.

    Science.gov (United States)

    Bonam, Matthew; Christopher, David; Cipolla, David; Donovan, Brent; Goodwin, David; Holmes, Susan; Lyapustina, Svetlana; Mitchell, Jolyon; Nichols, Steve; Pettersson, Gunilla; Quale, Chris; Rao, Nagaraja; Singh, Dilraj; Tougas, Terrence; Van Oort, Mike; Walther, Bernd; Wyka, Bruce

    2008-01-01

    The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD).

  1. Waste Minimization and Pollution Prevention Awareness Plan

    International Nuclear Information System (INIS)

    1994-04-01

    The purpose of this plan is to document Lawrence Livermore National Laboratory (LLNL) projections for present and future waste minimization and pollution prevention. The plan specifies those activities and methods that are or will be used to reduce the quantity and toxicity of wastes generated at the site. It is intended to satisfy Department of Energy (DOE) requirements. This Plan provides an overview of projected activities from FY 1994 through FY 1999. The plans are broken into site-wide and problem-specific activities. All directorates at LLNL have had an opportunity to contribute input, to estimate budget, and to review the plan. In addition to the above, this plan records LLNL's goals for pollution prevention, regulatory drivers for those activities, assumptions on which the cost estimates are based, analyses of the strengths of the projects, and the barriers to increasing pollution prevention activities

  2. Systems for tracking minimally invasive surgical instruments.

    Science.gov (United States)

    Chmarra, M K; Grimbergen, C A; Dankelman, J

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is necessary to track and record the motions of laparoscopic instruments. This article describes the state of the art in research on tracking systems for laparoscopy. It gives an overview on existing systems, on how these systems work, their advantages, and their shortcomings. Although various approaches have been used, none of the tracking systems to date comes out as clearly superior. A great number of systems can be used in training environment only, most systems do not allow the use of real laparoscopic instruments, and only a small number of systems provide force feedback.

  3. Discontinuity minimization for omnidirectional video projections

    Science.gov (United States)

    Alshina, Elena; Zakharchenko, Vladyslav

    2017-09-01

    Advances in display technologies both for head mounted devices and television panels demand resolution increase beyond 4K for source signal in virtual reality video streaming applications. This poses a problem of content delivery trough a bandwidth limited distribution networks. Considering a fact that source signal covers entire surrounding space investigation reviled that compression efficiency may fluctuate 40% in average depending on origin selection at the conversion stage from 3D space to 2D projection. Based on these knowledge the origin selection algorithm for video compression applications has been proposed. Using discontinuity entropy minimization function projection origin rotation may be defined to provide optimal compression results. Outcome of this research may be applied across various video compression solutions for omnidirectional content.

  4. Storage of RF photons in minimal conditions

    Science.gov (United States)

    Cromières, J.-P.; Chanelière, T.

    2018-02-01

    We investigate the minimal conditions to store coherently a RF pulse in a material medium. We choose a commercial quartz as a memory support because it is a widely available component with a high Q-factor. Pulse storage is obtained by varying dynamically the light-matter coupling with an analog switch. This parametric driving of the quartz dynamics can be alternatively interpreted as a stopped-light experiment. We obtain an efficiency of 26%, a storage time of 209 μs and a time-to-bandwidth product of 98 by optimizing the pulse temporal shape. The coherent character of the storage is demonstrated. Our goal is to connect different types of memories in the RF and optical domain for quantum information processing. Our motivation is essentially fundamental.

  5. Error minimizing algorithms for nearest eighbor classifiers

    Energy Technology Data Exchange (ETDEWEB)

    Porter, Reid B [Los Alamos National Laboratory; Hush, Don [Los Alamos National Laboratory; Zimmer, G. Beate [TEXAS A& M

    2011-01-03

    Stack Filters define a large class of discrete nonlinear filter first introd uced in image and signal processing for noise removal. In recent years we have suggested their application to classification problems, and investigated their relationship to other types of discrete classifiers such as Decision Trees. In this paper we focus on a continuous domain version of Stack Filter Classifiers which we call Ordered Hypothesis Machines (OHM), and investigate their relationship to Nearest Neighbor classifiers. We show that OHM classifiers provide a novel framework in which to train Nearest Neighbor type classifiers by minimizing empirical error based loss functions. We use the framework to investigate a new cost sensitive loss function that allows us to train a Nearest Neighbor type classifier for low false alarm rate applications. We report results on both synthetic data and real-world image data.

  6. Minimal models for axion and neutrino

    Directory of Open Access Journals (Sweden)

    Y.H. Ahn

    2016-01-01

    Full Text Available The PQ mechanism resolving the strong CP problem and the seesaw mechanism explaining the smallness of neutrino masses may be related in a way that the PQ symmetry breaking scale and the seesaw scale arise from a common origin. Depending on how the PQ symmetry and the seesaw mechanism are realized, one has different predictions on the color and electromagnetic anomalies which could be tested in the future axion dark matter search experiments. Motivated by this, we construct various PQ seesaw models which are minimally extended from the (non- supersymmetric Standard Model and thus set up different benchmark points on the axion–photon–photon coupling in comparison with the standard KSVZ and DFSZ models.

  7. Minimizing embarrassment: boys' experiences of pubertal changes.

    Science.gov (United States)

    Flaming, D; Morse, J M

    1991-01-01

    As very little is known about boys' subjective and emotional experiences when going through puberty, the qualitative research method of grounded theory was used in this study to address the question: "What is the experience of the physical maturational changes in male adolescents?" A Basic Social Psychological Process emerged, Minimizing Embarrassment, with four stages: waiting for the change, noticing the change, dealing with the change, and feeling comfortable with the change. Boys developed expectations from listening to others, by looking at older males, and by wondering and imagining what the changes would eventually be like for them. After developing these expectations, they compared their physical changes to others and to their own expectations. If the boys felt they were different from their peers, they worried about this difference. They used strategies such as avoiding, pretending, and joking to avoid embarrassment or to deal with embarrassing situations. If the boys felt they were "normal," they accepted the fact that they were maturing properly.

  8. Asymptotically safe non-minimal inflation

    Energy Technology Data Exchange (ETDEWEB)

    Tronconi, Alessandro, E-mail: Alessandro.Tronconi@bo.infn.it [Dipartimento di Fisica e Astronomia and INFN, Via Irnerio 46,40126 Bologna (Italy)

    2017-07-01

    We study the constraints imposed by the requirement of Asymptotic Safety on a class of inflationary models with an inflaton field non-minimally coupled to the Ricci scalar. The critical surface in the space of theories is determined by the improved renormalization group flow which takes into account quantum corrections beyond the one loop approximation. The combination of constraints deriving from Planck observations and those from theory puts severe bounds on the values of the parameters of the model and predicts a quite large tensor to scalar ratio. We finally comment on the dependence of the results on the definition of the infrared energy scale which parametrises the running on the critical surface.

  9. Minimally invasive aesthetic procedures in young adults

    Directory of Open Access Journals (Sweden)

    Wollina U

    2011-03-01

    Full Text Available Uwe Wollina1, Alberto Goldman21Department of Dermatology and Allergology, Academic Teaching Hospital Dresden-Friedrichstadt, Dresden, Germany; 2Clinica Goldman, Porto Alegre, Rio Grande du Sul, BrazilAbstract: Age is a significant factor in modifying specific needs when it comes to medical aesthetic procedures. In this review we will focus on young adults in their third decade of life and review minimally invasive aesthetic procedures other than cosmetics and cosmeceuticals. Correction of asymmetries, correction after body modifying procedures, and facial sculpturing are important issues for young adults. The implication of aesthetic medicine as part of preventive medicine is a major ethical challenge that differentiates aesthetic medicine from fashion.Keywords: acne scars, ice pick scars, boxcar scars, fillers 

  10. Evolution of a minimal parallel programming model

    International Nuclear Information System (INIS)

    Lusk, Ewing; Butler, Ralph; Pieper, Steven C.

    2017-01-01

    Here, we take a historical approach to our presentation of self-scheduled task parallelism, a programming model with its origins in early irregular and nondeterministic computations encountered in automated theorem proving and logic programming. We show how an extremely simple task model has evolved into a system, asynchronous dynamic load balancing (ADLB), and a scalable implementation capable of supporting sophisticated applications on today’s (and tomorrow’s) largest supercomputers; and we illustrate the use of ADLB with a Green’s function Monte Carlo application, a modern, mature nuclear physics code in production use. Our lesson is that by surrendering a certain amount of generality and thus applicability, a minimal programming model (in terms of its basic concepts and the size of its application programmer interface) can achieve extreme scalability without introducing complexity.

  11. Euclidean wormholes with minimally coupled scalar fields

    International Nuclear Information System (INIS)

    Ruz, Soumendranath; Modak, Bijan; Debnath, Subhra; Sanyal, Abhik Kumar

    2013-01-01

    A detailed study of quantum and semiclassical Euclidean wormholes for Einstein's theory with a minimally coupled scalar field has been performed for a class of potentials. Massless, constant, massive (quadratic in the scalar field) and inverse (linear) potentials admit the Hawking and Page wormhole boundary condition both in the classically forbidden and allowed regions. An inverse quartic potential has been found to exhibit a semiclassical wormhole configuration. Classical wormholes under a suitable back-reaction leading to a finite radius of the throat, where the strong energy condition is satisfied, have been found for the zero, constant, quadratic and exponential potentials. Treating such classical Euclidean wormholes as an initial condition, a late stage of cosmological evolution has been found to remain unaltered from standard Friedmann cosmology, except for the constant potential which under the back-reaction produces a term like a negative cosmological constant. (paper)

  12. Higgs Phenomenology of Minimal Universal Extra Dimensions

    Directory of Open Access Journals (Sweden)

    Kakizaki Mitsuru

    2012-06-01

    Full Text Available The minimal model of Universal Extra Dimensions (MUED is briefly reviewed. We explain how the cross-sections for Higgs production via gluon fusion and decay into photons are modified, relative the the Standard Model (SM values, by KK particles running in loops, leading to an enhancement of the gg → h → γγ and gg → h → W+W− cross-sections. ATLAS and CMS searches for the SM Higgs in these channels are reinterpreted in the context of MUED and used to place new limits on the MUED parameter space. Only a small region of between 1 and 3 GeV around mh = 125 GeV for 500 GeV < R−1 < 1600 GeV remains open at the 95 % confidence level.

  13. Minimal residual disease in chronic lymphocytic leukaemia.

    Science.gov (United States)

    García Vela, José Antonio; García Marco, José Antonio

    2018-02-23

    Minimal residual disease (MRD) assessment is an important endpoint in the treatment of chronic lymphocytic leukaemia (CLL). It is highly predictive of prolonged progression-free survival (PFS) and overall survival and could be considered a surrogate for PFS in the context of chemoimmunotherapy based treatment. Evaluation of MRD level by flow cytometry or molecular techniques in the era of the new BCR and Bcl-2 targeted inhibitors could identify the most cost-effective and durable treatment sequencing. A therapeutic approach guided by the level of MRD might also determine which patients would benefit from an early stop or consolidation therapy. In this review, we discuss the different MRD methods of analysis, which source of tumour samples must be analysed, the future role of the detection of circulating tumour DNA, and the potential role of MRD negativity in clinical practice in the modern era of CLL therapy. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  14. Perceptions of Sexual Orientation From Minimal Cues.

    Science.gov (United States)

    Rule, Nicholas O

    2017-01-01

    People derive considerable amounts of information about each other from minimal nonverbal cues. Apart from characteristics typically regarded as obvious when encountering another person (e.g., age, race, and sex), perceivers can identify many other qualities about a person that are typically rather subtle. One such feature is sexual orientation. Here, I review the literature documenting the accurate perception of sexual orientation from nonverbal cues related to one's adornment, acoustics, actions, and appearance. In addition to chronicling studies that have demonstrated how people express and extract sexual orientation in each of these domains, I discuss some of the basic cognitive and perceptual processes that support these judgments, including how cues to sexual orientation manifest in behavioral (e.g., clothing choices) and structural (e.g., facial morphology) signals. Finally, I attend to boundary conditions in the accurate perception of sexual orientation, such as the states, traits, and group memberships that moderate individuals' ability to reliably decipher others' sexual orientation.

  15. Minimally invasive hysterectomy in Coatis ( Nasua nasua

    Directory of Open Access Journals (Sweden)

    Bruno W. Minto

    Full Text Available ABSTRACT: Some wildlife species, such as coatis, have a high degree of adaptability to adverse conditions, such as fragmented urban forests, increasingly common on the world stage. The increase in the number of these mesopredators causes drastic changes in the communities of smaller predators, interferes with reproductive success of trees, as well as becoming a form of exchange between domestic and wild areas, favoring the transmission of zoonosis and increasing the occurrence of attacks to animals or people. This report describes the use of minimally invasive hysterectomy in two individuals of the species Nasua nasua, which can be accomplished through the use of hook technique, commonly used to castrate dogs and cats. The small incision and healing speed of incised tissues are fundamental in wild life management since the postoperative care is limited by the behavior of these animals. This technique proved to be effective and can greatly reduce the morbidity of this procedure in coatis.

  16. GLOBAL RISKS AND INSTRUMENTS OF ITS MINIMIZATION

    Directory of Open Access Journals (Sweden)

    O. Havryliuk

    2014-06-01

    Full Text Available It is argued that economic globalization leads to the formation of macro-economic, political and other risks that are able to grow into global risks affecting, without exception, all national economies, creating a serious threat to national economic security. The emphasis is on the negative elements of a set of global risks, their development and minimize the possibility of using a number of tools. Ensuring firmness of the state to external risks demands continuous monitoring and forecasting of world processes and usage of economic instruments of rapid response for prevention of negative consequences. The essence of the category of "risk" is revealed and deepened. The global risks that can not affect the economic security of Ukraine is disclosed. It is shown that the emergence of these global risks has negative impact on the economic security of Ukraine.

  17. Wilson expansion in the minimal subtraction scheme

    International Nuclear Information System (INIS)

    Smirnov, V.A.

    1989-01-01

    The small distance expansion of the product of composite fields is constructed for an arbitrary renormalization procedure of the type of minimal subtraction scheme. Coefficient functions of the expansion are expressed explicitly through the Green functions of composite fields. The expansion has the explicity finite form: the ultraviolet (UV) divergences of the coefficient functions and composite fields are removed by the initial renormalization procedure while the infrared (IR) divergences in massless diagrams with nonvanishing contribution into the coefficient functions are removed by the R-operation which is the IR part of the R-operation. The latter is the generalization of the dimensional renormalization in the case when both UV and IR divergences are present. To derive the expansion, a ''pre-subtracting operator'' is introduced and formulas of the counter-term technique are exploited

  18. Danish surgeons' views on minimally invasive surgery

    DEFF Research Database (Denmark)

    Edwards, Hellen; Jørgensen, Lars Nannestad

    2014-01-01

    BACKGROUND AND AIM: Advancements in minimally invasive surgery have led to increases in popularity of single-incision laparoscopic surgery (SILS) and natural orifice translumenal surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and Society of American...... Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) due to their postulated benefits of better cosmesis, less pain, and quicker recovery. This questionnaire-based study investigated Danish surgeons' attitudes toward these new procedures. SUBJECTS AND METHODS: A 26-item questionnaire was developed...... and distributed electronically via e-mail to a total of 1253 members of The Danish Society of Surgeons and The Danish Society of Young Surgeons. RESULTS: In total, 352 (approximately 30%) surgeons completed the questionnaire, 54.4% were over 50 years of age, and 76.6% were men. When choosing surgery, the most...

  19. Search for minimal paths in modified networks

    International Nuclear Information System (INIS)

    Yeh, W.-C.

    2002-01-01

    The problem of searching for all minimal paths (MPs) in a network obtained by modifying the original network, e.g. for network expansion or reinforcement, is discussed and solved in this study. The existing best-known method to solve this problem was a straightforward approach. It needed extensive comparison and verification, and failed to solve some special but important cases. Therefore, a more efficient, intuitive and generalized method to search for all MPs without an extensive research procedure is proposed. In this presentation, first we develop an intuitive algorithm based upon the reformation of all MPs in the original network to search for all MPs in a modified network. Next, the computational complexity of the proposed algorithm is analyzed and compared with the existing methods. Finally, examples illustrate how all MPs are generated in a modified network based upon the reformation of all of the MPs in the corresponding original network

  20. Minimalism in the modern short story

    Directory of Open Access Journals (Sweden)

    A Razi

    2009-09-01

    Full Text Available Short story has recently become the focus of attention in the late decades in Iran. The expanding value of writing short story is actually a reasonable outcome of the dominance of minimalism- a movement which is based upon simplicity and shortness. Minimalist writers, leaving out redundant features of narration, mainly focus on essentialities through applying a variety of techniques such as cuttings from the interesting moments of real life, evading introduction, applying inter-referents, choice of words, short stanzas and sentences and so on. Looking upon critic’s opinion about such a tendency over the past and present, this article will come up with a brief explanation of the properties of such stories. Finally a sample story “candles will never go dead” will be analyzed and discussed in the lights of such techniques.