WorldWideScience

Sample records for minimal contact therapies

  1. A review of technology-assisted self-help and minimal contact therapies for drug and alcohol abuse and smoking addiction: is human contact necessary for therapeutic efficacy?

    Science.gov (United States)

    Newman, Michelle G; Szkodny, Lauren E; Llera, Sandra J; Przeworski, Amy

    2011-02-01

    Technology-based self-help and minimal contact therapies have been proposed as effective and low-cost interventions for addictive disorders, such as nicotine, alcohol, and drug abuse and addiction. The present article reviews the literature published before 2010 on computerized treatments for drug and alcohol abuse and dependence and smoking addiction. Treatment studies are examined by disorder as well as amount of therapist contact, ranging from self-administered therapy and predominantly self-help interventions to minimal contact therapy where the therapist is actively involved in treatment but to a lesser degree than traditional therapy and predominantly therapist-administered treatments involving regular contact with a therapist for a typical number of sessions. In the treatment of substance use and abuse it is concluded that self-administered and predominantly self-help computer-based cognitive and behavioral interventions are efficacious, but some therapist contact is important for greater and more sustained reductions in addictive behavior. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Chances of cryosurgery in the minimal invasive therapy; Chancen der Kryochirurgie in der Minimal Invasiven Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Haensgen, H. [Institut fuer Luft- und Kaeltetechnik GmbH, Dresden (Germany). Fachbereich Klimatechnik; Binneberg, A. [Institut fuer Luft- und Kaeltetechnik GmbH, Dresden (Germany). Fachbereich Klimatechnik; Herzog, R. [Institut fuer Luft- und Kaeltetechnik GmbH, Dresden (Germany). Fachbereich Klimatechnik; Schumann, B. [Institut fuer Luft- und Kaeltetechnik GmbH, Dresden (Germany). Fachbereich Klimatechnik

    1995-01-01

    Object in view of the minimal invasive therapy is to substitute the traditional open and therefore invasive surgically interventions through fewer invasive surgery. Additional to preponderantly in MIT used microsurgery and laser-therapy also cryotherapy may be used. Clinical results in therapy of trigeminalneuralgia are present. Application of endoscopic cryotip are possible. (orig.)

  3. A Congruence Theorem for Minimal Surfaces in $S^{5}$ with Constant Contact Angle

    OpenAIRE

    Montes, Rodrigo Ristow; Verderesi, Jose A.

    2006-01-01

    We provide a congruence theorem for minimal surfaces in $S^5$ with constant contact angle using Gauss-Codazzi-Ricci equations. More precisely, we prove that Gauss-Codazzi-Ricci equations for minimal surfaces in $S^5$ with constant contact angle satisfy an equation for the Laplacian of the holomorphic angle. Also, we will give a characterization of flat minimal surfaces in $S^5$ with constant contact angle.

  4. Risk-optimized proton therapy to minimize radiogenic second cancers

    DEFF Research Database (Denmark)

    Rechner, Laura A; Eley, John G; Howell, Rebecca M

    2015-01-01

    Proton therapy confers substantially lower predicted risk of second cancer compared with photon therapy. However, no previous studies have used an algorithmic approach to optimize beam angle or fluence-modulation for proton therapy to minimize those risks. The objectives of this study were...... to demonstrate the feasibility of risk-optimized proton therapy and to determine the combination of beam angles and fluence weights that minimizes the risk of second cancer in the bladder and rectum for a prostate cancer patient. We used 6 risk models to predict excess relative risk of second cancer. Treatment...

  5. Minimal contact psychotherapy for sub-threshold depression in primary care: a randomised trial.

    NARCIS (Netherlands)

    Willemse, G.R.W.M.; Smit, F.; Cuijpers, W.J.M.J.; Tiemens, B.G.

    2004-01-01

    Background: Sub-threshold depression is a prognostic variable for major depression. Interventions in sub-threshold depression may prevent the onset of new cases of major depression. Aims: To examine the effects of minimal-contact psychotherapy in primary care patients with sub-threshold depression

  6. Interventional MRI of the breast: minimally invasive therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hall-Craggs, M.A. [MR Unit, Middlesex Hospital, London (United Kingdom)

    2000-01-01

    In recent years a variety of minimally invasive therapies have been applied to the treatment of breast lesions. These therapies include thermal treatments (interstitial laser coagulation, focused ultrasound, radiofrequency and cryotherapy), percutaneous excision, and interstitial radiotherapy. Magnetic resonance has been used in these treatments to visualize lesions before, during and after therapy and to guide interventions. ''Temperature-sensitive'' sequences have shown changes with thermal ablation which broadly correlate with areas of tumour necrosis. Consequently, MR has the potential to monitor treatment at the time of therapy. To date, experience in the treatment of breast cancer has been restricted to small studies. Large controlled studies are required to validate the efficacy and safety of these therapies in malignant disease. (orig.)

  7. Interventional MRI of the breast: minimally invasive therapy

    International Nuclear Information System (INIS)

    Hall-Craggs, M.A.

    2000-01-01

    In recent years a variety of minimally invasive therapies have been applied to the treatment of breast lesions. These therapies include thermal treatments (interstitial laser coagulation, focused ultrasound, radiofrequency and cryotherapy), percutaneous excision, and interstitial radiotherapy. Magnetic resonance has been used in these treatments to visualize lesions before, during and after therapy and to guide interventions. ''Temperature-sensitive'' sequences have shown changes with thermal ablation which broadly correlate with areas of tumour necrosis. Consequently, MR has the potential to monitor treatment at the time of therapy. To date, experience in the treatment of breast cancer has been restricted to small studies. Large controlled studies are required to validate the efficacy and safety of these therapies in malignant disease. (orig.)

  8. Perspectives of Nanotechnology in Minimally Invasive Therapy of Breast Cancer

    Directory of Open Access Journals (Sweden)

    Yamin Yang

    2013-01-01

    Full Text Available Breast cancer, the most common type of cancer among women in the western world, affects approximately one out of every eight women over their lifetime. In recognition of the high invasiveness of surgical excision and severe side effects of chemical and radiation therapies, increasing efforts are made to seek minimally invasive modalities with fewer side effects. Nanoparticles (<100 nm in size have shown promising capabilities for delivering targeted therapeutic drugs to cancer cells and confining the treatment mainly within tumors. Additionally, some nanoparticles exhibit distinct properties, such as conversion of photonic energy into heat, and these properties enable eradication of cancer cells. In this review, current utilization of nanostructures for cancer therapy, especially in minimally invasive therapy, is summarized with a particular interest in breast cancer.

  9. Risk-optimized proton therapy to minimize radiogenic second cancers

    Science.gov (United States)

    Rechner, Laura A.; Eley, John G.; Howell, Rebecca M.; Zhang, Rui; Mirkovic, Dragan; Newhauser, Wayne D.

    2015-01-01

    Proton therapy confers substantially lower predicted risk of second cancer compared with photon therapy. However, no previous studies have used an algorithmic approach to optimize beam angle or fluence-modulation for proton therapy to minimize those risks. The objectives of this study were to demonstrate the feasibility of risk-optimized proton therapy and to determine the combination of beam angles and fluence weights that minimize the risk of second cancer in the bladder and rectum for a prostate cancer patient. We used 6 risk models to predict excess relative risk of second cancer. Treatment planning utilized a combination of a commercial treatment planning system and an in-house risk-optimization algorithm. When normal-tissue dose constraints were incorporated in treatment planning, the risk model that incorporated the effects of fractionation, initiation, inactivation, and repopulation selected a combination of anterior and lateral beams, which lowered the relative risk by 21% for the bladder and 30% for the rectum compared to the lateral-opposed beam arrangement. Other results were found for other risk models. PMID:25919133

  10. Two Studies of the Long-Term Follow-up of Minimal Therapist Contact Treatments of Vascular and Tension Headache.

    Science.gov (United States)

    Blanchard, Edward B.; And Others

    1988-01-01

    Followed up on tension and vascular headache patients, intially treated with biofeedback and/or relaxation training in either a minimal therapist contact or an intensive individual protocol, where one-half of patients continued keeping headache diaries and were seen monthly; others had minimal contact. Demonstrated equally good maintenance from…

  11. Optimal antiviral switching to minimize resistance risk in HIV therapy.

    Directory of Open Access Journals (Sweden)

    Rutao Luo

    Full Text Available The development of resistant strains of HIV is the most significant barrier to effective long-term treatment of HIV infection. The most common causes of resistance development are patient noncompliance and pre-existence of resistant strains. In this paper, methods of antiviral regimen switching are developed that minimize the risk of pre-existing resistant virus emerging during therapy switches necessitated by virological failure. Two distinct cases are considered; a single previous virological failure and multiple virological failures. These methods use optimal control approaches on experimentally verified mathematical models of HIV strain competition and statistical models of resistance risk. It is shown that, theoretically, order-of-magnitude reduction in risk can be achieved, and multiple previous virological failures enable greater success of these methods in reducing the risk of subsequent treatment failures.

  12. Minimalism

    CERN Document Server

    Obendorf, Hartmut

    2009-01-01

    The notion of Minimalism is proposed as a theoretical tool supporting a more differentiated understanding of reduction and thus forms a standpoint that allows definition of aspects of simplicity. This book traces the development of minimalism, defines the four types of minimalism in interaction design, and looks at how to apply it.

  13. Minimizing Sources of Airborne, Aerosolized, and Contact Contaminants in the OR Environment.

    Science.gov (United States)

    Armellino, Donna

    2017-12-01

    Surgical site infections are unintended consequences of surgery that can cause harm to patients and place financial burdens on health care organizations. Extrinsic factors in the OR-including health care providers' behavior and practices that modify air movement, the physical environment, equipment, or surgical instruments-can increase microbial contamination. Microbes can be transported into the surgical incision by airborne or contact routes and contribute to a surgical site infection. Simple practices to prevent infection-such as minimizing airborne particles and contaminants, maintaining equipment according to the manufacturer's recommendations, cleaning and disinfecting the environment and surgical instruments, and performing proper hand hygiene-can reduce the degree of microbial contamination. Perioperative leaders and health care providers can help decrease the patient's risk of surgical site infection with proactive preventive practices that break the chain of infection. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. A planar PDMS micropump using in-contact minimized-leakage check valves

    International Nuclear Information System (INIS)

    Ni, Junhui; Li, Beizhi; Huang, Fengliang; Wang, Bin; Lin, Qiao

    2010-01-01

    We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap–stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e.g. chamber height) and operating parameters (e.g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 µL min −1 and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.

  15. Chemokine Signaling in Allergic Contact Dermatitis: Toward Targeted Therapies.

    Science.gov (United States)

    Smith, Jeffrey S; Rajagopal, Sudarshan; Atwater, Amber Reck

    2018-06-22

    Allergic contact dermatitis (ACD) is a common skin disease that results in significant cost and morbidity. Despite its high prevalence, therapeutic options are limited. Allergic contact dermatitis is regulated primarily by T cells within the adaptive immune system, but also by natural killer and innate lymphoid cells within the innate immune system. The chemokine receptor system, consisting of chemokine peptides and chemokine G protein-coupled receptors, is a critical regulator of inflammatory processes such as ACD. Specific chemokine signaling pathways are selectively up-regulated in ACD, most prominently CXCR3 and its endogenous chemokines CXCL9, CXCL10, and CXCL11. Recent research demonstrates that these 3 chemokines are not redundant and indeed activate distinct intracellular signaling profiles such as those activated by heterotrimeric G proteins and β-arrestin adapter proteins. Such differential signaling provides an attractive therapeutic target for novel ACD therapies and other inflammatory diseases.

  16. Rapid cell separation with minimal manipulation for autologous cell therapies

    Science.gov (United States)

    Smith, Alban J.; O'Rorke, Richard D.; Kale, Akshay; Rimsa, Roberts; Tomlinson, Matthew J.; Kirkham, Jennifer; Davies, A. Giles; Wälti, Christoph; Wood, Christopher D.

    2017-02-01

    The ability to isolate specific, viable cell populations from mixed ensembles with minimal manipulation and within intra-operative time would provide significant advantages for autologous, cell-based therapies in regenerative medicine. Current cell-enrichment technologies are either slow, lack specificity and/or require labelling. Thus a rapid, label-free separation technology that does not affect cell functionality, viability or phenotype is highly desirable. Here, we demonstrate separation of viable from non-viable human stromal cells using remote dielectrophoresis, in which an electric field is coupled into a microfluidic channel using shear-horizontal surface acoustic waves, producing an array of virtual electrodes within the channel. This allows high-throughput dielectrophoretic cell separation in high conductivity, physiological-like fluids, overcoming the limitations of conventional dielectrophoresis. We demonstrate viable/non-viable separation efficacy of >98% in pre-purified mesenchymal stromal cells, extracted from human dental pulp, with no adverse effects on cell viability, or on their subsequent osteogenic capabilities.

  17. The prospect of minimally invasive therapy for oncology in 21st century

    International Nuclear Information System (INIS)

    Wu Peihong

    2005-01-01

    Minimally invasive therapy and biotherapy are two tendencies in medicine of the 21st century. It is minimally invasive with exact fixing and therapy, few pains and fast recovery. By the host self defecnce mechanism and biologicals, confinement of tumor and decreasing recurrence will give improvement to the patient's quality of life. The followings are the megatrends of minimally invasive therapy in the 21st century: 1. Follow closely with new technology; 2. Exact fixing and therapy; 3. Mode of sequencely combination; 4. Combined with immunotherapy; 5. Radical cure of minimally invasive therapy on oncology. New mode of minimally invasive therapy combined with biotherapy is expected as an important ingredient for oncotherapy in the 21 century. (authors)

  18. Cost-effectiveness of opportunistic screening and minimal contact psychotherapy to prevent depression in primary care patients

    NARCIS (Netherlands)

    J.M. van den Berg (Merlijn); F. Smit (Filip); T. Vos (Theo); P.H.M. Van Baal (Pieter)

    2011-01-01

    textabstractBackground: Depression causes a large burden of disease worldwide. Effective prevention has the potential to reduce that burden considerably. This study aimed to investigate the cost-effectiveness of minimal contact psychotherapy, based on Lewinsohn's 'Coping with depression' course,

  19. Treatment of cervical agenesis with minimally invasive therapy: Case report

    Directory of Open Access Journals (Sweden)

    Azami Denas Azinar

    2017-11-01

    Full Text Available Cervical agenesis is very rare congenital disorder case with cervical not formed. Because of cervical clogged so that menstruation can not be drained. We Report the case of a19 years old women still single with endometrioma, hematometra, cervical agenesis and perform surgery combination laparoscopy and transvaginally with laparoscopic cystectomy, neocervix, and use catheter no 24f in the new cervix. And now she can currently be normal menstruation. Minimally invasive theraphy of congenital anomalies case is recommended to save reproductive function. Keywords: Cervical agenesis, minimal invasive theraphy

  20. Nonsurgical, image-guided, minimally invasive therapy for thyroid nodules

    DEFF Research Database (Denmark)

    Gharib, Hossein; Hegedüs, Laszlo; Pacella, Claudio Maurizio

    2013-01-01

    evaluation. These techniques have also been applied to recurrent locoregional cervical thyroid cancer with encouraging initial results, although still limited data. Conclusions: Surgery and radioiodine remain as conventional and established treatments for nodular goiters. However, the new image......Context: Nodular thyroid disease is very common. Most nodules are asymptomatic, are benign by fine-needle aspiration, remain stable, and can be followed by observation alone in the majority of the patients. Occasionally, nodules grow or cause symptoms requiring treatment. So far, surgery has been...... our main option for treatment. Objective: In this review, we discuss nonsurgical, minimally invasive approaches for small thyroid masses, including indications, efficacy, side effects, and costs. Evidence Acquisition: We selected recent publications related to minimally invasive thyroid techniques...

  1. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

    Science.gov (United States)

    Howell, Stephen M; Hodapp, Esther E; Vernace, Joseph V; Hull, Maury L; Meade, Thomas D

    2013-10-01

    Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.

  2. Individualized Low-Amplitude Seizure Therapy: Minimizing Current for Electroconvulsive Therapy and Magnetic Seizure Therapy

    Science.gov (United States)

    Peterchev, Angel V; Krystal, Andrew D; Rosa, Moacyr A; Lisanby, Sarah H

    2015-01-01

    Electroconvulsive therapy (ECT) at conventional current amplitudes (800–900 mA) is highly effective but carries the risk of cognitive side effects. Lowering and individualizing the current amplitude may reduce side effects by virtue of a less intense and more focal electric field exposure in the brain, but this aspect of ECT dosing is largely unexplored. Magnetic seizure therapy (MST) induces a weaker and more focal electric field than ECT; however, the pulse amplitude is not individualized and the minimum amplitude required to induce a seizure is unknown. We titrated the amplitude of long stimulus trains (500 pulses) as a means of determining the minimum current amplitude required to induce a seizure with ECT (bilateral, right unilateral, bifrontal, and frontomedial electrode placements) and MST (round coil on vertex) in nonhuman primates. Furthermore, we investigated a novel method of predicting this amplitude-titrated seizure threshold (ST) by a non-convulsive measurement of motor threshold (MT) using single pulses delivered through the ECT electrodes or MST coil. Average STs were substantially lower than conventional pulse amplitudes (112–174 mA for ECT and 37.4% of maximum device amplitude for MST). ST was more variable in ECT than in MST. MT explained 63% of the ST variance and is hence the strongest known predictor of ST. These results indicate that seizures can be induced with less intense electric fields than conventional ECT that may be safer; efficacy and side effects should be evaluated in clinical studies. MT measurement could be a faster and safer alternative to empirical ST titration for ECT and MST. PMID:25920013

  3. [Minimally invasive surgical therapy of gynecomastia: liposuction and exeresis technique].

    Science.gov (United States)

    Voigt, M; Walgenbach, K J; Andree, C; Bannasch, H; Looden, Z; Stark, G B

    2001-10-01

    A number of techniques are available for the correction of gynecomastia. Nonscarring sparing methods are preferred, and the minimally invasive technique is to use liposuction for the gland and the fatty tissue exclusively. In this retrospective study we present our experience with a combination of liposuction and subsequent resection of the remaining gland. Sixty-two patients (112 breasts) were surgically treated for gynecomastia from January 1996 and September 2000. From 1996 to 1997 all patients suffering from gynecomastia grade Simon I-II were treated by the method described by Rosenberg and Stark, which is exclusively suction of the fatty and glandular tissue. In a retrospective chart study a high recurrence rate was found in these patients. Subsequently we changed our technique to liposuction of the fatty tissue followed by sharp excision of the glandular tissue through the incision made for the liposuction cannula in the submammary fold. Suction alone was not sufficient to remove the glandular tissue; the rate of recurrence after suction was 35%. When sharp resection of the glandular tissue was carried out after the liposuction the recurrence rate dropped to under 10%. In total our complication rate was 50% including minor sequelae. The most frequent complication was unacceptable scarring of the nipple-areola complex. Hypesthesia of the nipple-areola occurred in 13.4% of the patients. The combination of liposuction and resection of the glandular tissue is a minimally invasive correction that can be used in all cases of gynecomastia grade Simon I-II.

  4. Modification of a Superficial X-Ray Therapy Machine for Rectal Contact Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Barish, Robert J.; Donohue, Karen Episcopia

    2015-01-15

    X-ray therapy of superficial rectal cancers using a hand-held 50 kV contact unit (Philips RT-50) in a technique first described by Papillon had reached a point of widening clinical acceptability when the manufacturer of this equipment discontinued its production. To pursue this endocavitary approach to rectal therapy, technical modifications have to be made to conventional superficial x-ray therapy machines. Advantages over the original Papillon method include remote viewing of the lesion through the proctoscopic cone and a lower radiation exposure for the operator. We have evaluated a Bucky Combination Therapy Unit under conditions in which the operating voltage (65 kV), target skin distance (23.6 cm), and added filtration (0.39 mm Al) were selected in order to match as closely as possible the beam penetration characteristics of the “standard” (Papillon) technique. With this equipment, the thermal characteristics of the tube anode and housing limit the amount of radiation that can be delivered before a “rest period” for the machine is needed. In practice, 3 minutes of irradiation at an exposure rate of 500 R/min can be performed followed by an interval of 3 minutes before irradiation can be resumed.

  5. Design and fabrication of robotic gripper for grasping in minimizing contact force

    Science.gov (United States)

    Heidari, Hamidreza; Pouria, Milad Jafary; Sharifi, Shahriar; Karami, Mahmoudreza

    2018-03-01

    This paper presents a new method to improve the kinematics of robot gripper for grasping in unstructured environments, such as space operations. The robot gripper is inspired from the human hand and kept the hand design close to the structure of human fingers to provide successful grasping capabilities. The main goal is to improve kinematic structure of gripper to increase the grasping capability of large objects, decrease the contact forces and makes a successful grasp of various objects in unstructured environments. This research will describe the development of a self-adaptive and reconfigurable robotic hand for space operations through mechanical compliance which is versatile, robust and easy to control. Our model contains two fingers, two-link and three-link, with combining a kinematic model of thumb index. Moreover, some experimental tests are performed to examine the effectiveness of the hand-made in real, unstructured tasks. The results represent that the successful grasp range is improved about 30% and the contact forces is reduced approximately 10% for a wide range of target object size. According to the obtained results, the proposed approach provides an accommodative kinematic model which makes the better grasping capability by fingers geometries for a robot gripper.

  6. Close contact dose: a radioiodine therapy case study

    International Nuclear Information System (INIS)

    Tuchyna, T.

    2002-01-01

    Full text: External radiation dose rates were measured immediately post administration and periodically thereafter at 0.3 and 1.0 m from a patient who received a 555 MBq therapeutic dose of I-131. The dose received by the partner during the close contact period of sleep was measured with an anthropomorphic RANDO phantom representing a standard man with ICRP60 organs critical for dosimetry. RANDO occupied the same bed as the patient at a skin to skin distance of 30 cm with up to 30 TLD rods (1 x 1 x 6mm, LiF:Mg) inserted at critical organ positions within the phantom. The measurements were compared with empirical estimates provided by the Close Contact Dose Spreadsheet (Cormack and Shearer, 1998). The measured external dose rate of 19.3microSv/hr obtained immediately post administration rose slightly, to 26.3microSv/hr during the first 12 hours, however subsequently demonstrated a slow decrease. The TLDs embed- ded in RANDO recorded a dose of 0.24mSv during the hours of sleep. The total dose received by the partner over the two days was 0.29mSv, which compared favourably with a figure of 0.31mSv obtained by the Close Contact Dose Spreadsheet. The doses received demonstrate the validity of restricting patient partner contact during the hours of sleep within the first few days post administration. Monitoring of the bedroom, bed linen, bathroom, toilet and personal effects showed slight levels of contamination ranging from background to 20 cps. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Post-coma persons emerging from a minimally conscious state with multiple disabilities make technology-aided phone contacts with relevant partners

    NARCIS (Netherlands)

    Lancioni, G.E.; Singh, N.N.; O'Reilly, M.F.; Sigafoos, J.; Oliva, D.; Campodonico, F.; D'Amico, F.; Buonocunto, F.; Sacco, V.; Didden, H.C.M.

    2013-01-01

    Post-coma individuals emerging from a minimally conscious state with multiple disabilities may enjoy contact with relevant partners (e.g., family members and friends), but may not have easy access to them. These two single-case studies assessed whether those individuals could make contact with

  8. Interferon-gamma release assay and Rifampicin therapy for household contacts of tuberculosis.

    Science.gov (United States)

    Wang, Jann-Yuan; Shu, Chin-Chung; Lee, Chih-Hsin; Yu, Chong-Jen; Lee, Li-Na; Yang, Pan-Chyr

    2012-03-01

    Longitudinal studies in household contacts to identify subgroups at risk of active tuberculosis are lacking. Household contacts of pulmonary tuberculosis patients were prospectively enrolled to receive chest radiography, sputum studies, and T-SPOT.TB assay at initial visit. Repeat examinations every 6 months for 3 years, and 4-month rifampin preventive therapy for T-SPOT.TB-positive contacts were provided. We investigated factors predicting T-SPOT.TB-positivity and active pulmonary tuberculosis. 583 contacts were enrolled with a follow-up duration of 20.7 ± 9.4 months. 176 (30.2%) were T-SPOT.TB-positive initially and 32 (18.2%) of them received preventive therapy. Old age, living in the same room/house with the index case, the index case having a high smear grade (3+ ∼ 4+) and pulmonary cavitation were associated with T-SPOT.TB-positivity. Active tuberculosis developed in 9 T-SPOT.TB-positive contacts; risk factors included T-SPOT.TB-positivity without preventive therapy, living in the same room, and the index case being ≤50 years or female. 108 (61.4%) T-SPOT.TB-positive contacts had repeat examinations. Forty-five had T-SPOT.TB reversion and none of them developed active tuberculosis. Household contacts who are T-SPOT.TB-positive and live in the same room as the index case are at risk of active tuberculosis and require preventive therapy and close follow-up. Copyright © 2011 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  9. Image-guided therapy and minimally invasive surgery in children: a merging future

    International Nuclear Information System (INIS)

    Shlomovitz, Eran; Amaral, Joao G.; Chait, Peter G.

    2006-01-01

    Minimally invasive image-guided therapy for children, also known as pediatric interventional radiology (PIR), is a new and exciting field of medicine. Two key elements that helped the rapid evolution and dissemination of this specialty were the creation of devices appropriate for the pediatric population and the development of more cost-effective and minimally invasive techniques. Despite its clear advantages to children, many questions are raised regarding who should be performing these procedures. Unfortunately, this is a gray zone with no clear answer. Surgeons fear that interventional radiologists will take over additional aspects of the surgical/procedural spectrum. Interventional radiologists, on the other hand, struggle to avoid becoming highly specialized technicians rather than physicians who are responsible for complete care of their patients. In this article, we briefly discuss some of the current aspects of minimally invasive image-guided therapy in children and innovations that are expected to be incorporated into clinical practice in the near future. Then, we approach the current interspecialty battles over the control of this field and suggest some solutions to these issues. Finally, we propose the development of a generation of physicians with both surgical and imaging skills. (orig.)

  10. Minimally invasive vacuum-assisted closure therapy in the management of complex pleural empyema.

    Science.gov (United States)

    Sziklavari, Zsolt; Grosser, Christian; Neu, Reiner; Schemm, Rudolf; Szöke, Tamas; Ried, Michael; Hofmann, Hans-Stefan

    2013-07-01

    The pool of potential candidates for pleural empyema is expanding. In a previous technical report, we tested the feasibility of the minimally invasive insertion of a vacuum-assisted closure (Mini-VAC) system without the insertion of an open-window thoracostomy (OWT). In this study, we describe a consecutive case series of complex pleural empyemas that were managed by this Mini-VAC therapy. In this retrospective study, we investigated 6 patients with multimorbidity (Karnofsky index ≤ 50%) who were consecutively treated with Mini-VAC for a primary, postoperative or recurrent pleural empyema between January 2011 and February 2012. Local control of the infection and control of sepsis were satisfactory in all 6 of the patients treated by Mini-VAC therapy. The suction used did not create any air leaks or bleeding from the lung or mediastinal structures. Mini-VAC therapy allowed a reduction of the empyema cavity and improved the re-expansion of the residual lung. Mini-VAC therapy resulted in a rapid eradication of the empyema. The chest wall was closed in all patients during the first hospital stay. All patients left the hospital in good health (Karnofsky index >70%) and with a non-infected pleural cavity at a mean of 22 ± 11 days after Mini-VAC installation. Pleural empyema was not detected in any of the 6 patients at the 3-month follow-up appointment. The Mini-VAC procedure with the abdication of an OWT offers a rapid treatment for complex pleural empyema with minimal surgical effort and the opportunity for a primary closure of the empyema cavity.

  11. Minimally invasive therapy of upside-down stomach: A single-center experience

    Directory of Open Access Journals (Sweden)

    Radek Vrba

    2017-01-01

    Full Text Available Introduction: The aim of this study is to evaluate short-term and long-term outcomes of minimally invasive therapy in Type IV hiatal hernia (upside-down stomach. Patients and Methods: A retrospective study of 58 consecutively operated patients with Type IV hiatal hernia between 1998 and 2015 was conducted. Short-term outcome was evaluated using Clavien-Dindo classification and long-term outcomes using phone survey and subjective assessment of patients at least 1 year following surgery. Results: Laparoscopic hiatoplasty was performed in all patients, with gastropexy in 55.2%, fundoplication in 39.6%, and combination of fundoplication and gastropexy in 5.2%. Complications were observed in 6.9%. Two early reoperations (within 30 days due to acute reherniation were necessary. Adverse events occurred in seven cases – pleural opening and peroperative bleeding. Three patients were reoperated laparoscopically 2–17 months after the first surgery due to receiving partial stomach herniation. In 67.2% of patients, long-term subjective quality of life assessment was available. Eighty percent of them were completely satisfied, without recurrence of preoperative symptoms. Conclusion: Elective laparoscopic surgery of hiatal hernia Type IV is a safe procedure, which has all the benefits of minimally invasive therapy with favorable short- and long-term results.

  12. The culture of massage therapy: valued elements and the role of comfort, contact, connection and caring.

    Science.gov (United States)

    Smith, Joanna M; Sullivan, S John; Baxter, G David

    2009-08-01

    To explore the attributes of the therapy encounter valued by repeat users of health-related massage therapy. A qualitative design with telephone focus group methodology was used. A total of 19 repeat users of massage therapy participated in three telephone focus groups where audiotaped semi-structured interviews were conducted. Telephone focus group with massage clients from a range of provincial and urban regions in New Zealand. Summary of reported themes of the massage experience. Data were thematically analysed using the general inductive approach. Six valued elements of the massage encounter (time for care and personal attention, engaging and competent therapist, trust partnership, holism and empowerment, effective touch and enhancing relaxation), four modulators (comfort, contact, connection and caring) and two themes relating to adding experiential value (enjoyment, escapism) characterize the massage therapy culture. The culture of massage therapy care incorporates a number of characteristics that are congruent with the complementary and alternative medicine approach to health. In addition, massage specific factors were identified. The humanistic aspects of the therapy encounter valued by clients offer insight into the growing use of massage therapy and the success of massage therapy outcomes.

  13. Neurophysiological and behavioural responses to music therapy in vegetative and minimally conscious states

    Directory of Open Access Journals (Sweden)

    Julian eO'Kelly

    2013-12-01

    Full Text Available Assessment of awareness for those with disorders of consciousness (DOC is a challenging undertaking, due to the complex presentation of the population, where misdiagnosis rates remain high. Music therapy may be effective in the assessment and rehabilitation with this population due to effects of musical stimuli on arousal, attention and emotion, irrespective of verbal or motor deficits, however, an evidence base is lacking. To address this, a neurophysiological and behavioural study was undertaken comparing EEG, heart rate variability, respiration and behavioural responses of 20 healthy subjects with 21 individuals in vegetative or minimally conscious states (VS or MCS. Subjects were presented with live preferred music and improvised music entrained to respiration (i.e., music therapy procedures, recordings of disliked music, white noise and silence. ANOVA tests indicated a range of significant responses (p ≤ 0.05 across healthy subjects corresponding to arousal and attention in response to preferred music including concurrent increases in respiration rate with globally enhanced EEG power spectra responses across frequency bandwidths. Whilst physiological responses were heterogeneous across patients, significant post hoc EEG amplitude increases for stimuli associated with preferred music were found for frontal midline theta in 6 VS and 4 MCS subjects, and frontal alpha in 3 VS and 4 MCS subjects (p = 0.05 - 0.0001. Furthermore, behavioural data showed a significantly increased blink rate for preferred music (p = 0.029 across the VS cohort. Two VS cases are presented with concurrent changes (p ≤ 0.05 across measures indicative of discriminatory responses to both music therapy procedures. A MCS case study highlights how more sensitive selective attention may distinguish MCS from VS. Further investigation is warranted to explore the use of music therapy for prognostic indicators, and its potential to support neuroplasticity in rehabilitation

  14. Minimally invasive neuronavigator-guided microsurgery and photodynamic therapy for gliomas.

    Science.gov (United States)

    Wang, Yezhong; Lei, Ting; Wang, Zhi

    2009-06-01

    In order to evaluate the effectiveness of neuronavigator-guided microsurgery and keyhole technique for the resection of gliomas, a total of 60 patients with gliomas were exactly located by using neuronavigator during microsurgery. Forty deep-seated gliomas were resected through a keyhole operative approach. Thirty out of the 60 cases were subjected to photodynamic therapy (PDT) after tumor resection. The therapeutic effectiveness of all the cases was recorded and analyzed. The results showed that glioma was totally resected in 52 cases (86.7%), subtotally in 5 (8.3%), and most partially in 3 (5%). Neurological deficits occurred postoperatively in 4 cases. One patient died of multiple system organ failure 4 days after operation. It was concluded that the application of minimally invasive technique could dramatically decrease surgical complications following resection of glioma, and its combination with PDT could obviously improve the quality of life of patients and prolong the survival time.

  15. Development of a quantum dot mediated thermometry for minimally invasive thermal therapy

    Science.gov (United States)

    Hanson, Willard L.

    Thermally-related, minimally invasive therapies are designed to treat tumors while minimizing damage to the surrounding tissues. Adjacent tissues become susceptible to thermal injury to ensure the cancer is completely destroyed. Destroying tumor cells, while minimizing collateral damage to the surrounding tissue, requires the capacity to control and monitor tissue temperatures both spatially and temporally. Current devices measure the tumor's tissue temperature at a specific location leaving the majority unmonitored. A point-wise application can not substantiate complete tumor destruction. This type of surgery would be more effective if volumetric tissue temperature measurement were available. On this premise, the feasibility of a quantum dot (QD) assembly to measure the tissue temperature volumetrically was tested in the experiments described in this dissertation. QDs are fluorescence semiconductor nanoparticles having various superior optical properties. This new QD-mediated thermometry is capable of monitoring the thermal features of tissues non-invasively by measuring the aggregate fluorescence intensity of the QDs accumulated at the target tissues prior to and during the surgical procedure. Thus, such a modality would allow evaluation of tissue destruction by measuring the fluorescence intensity of the QD as a function of temperature. The present study also quantified the photoluminescence intensity and attenuation of the QD as a function of depth and wavelength using a tissue phantom. A prototype system was developed to measure the illumination through a tissue phantom as a proof of concept of the feasibility of a noninvasive thermal therapy. This prototype includes experimental hardware, software and working methods to perform image acquisition, and data reduction strategic to quantify the intensity and transport characteristics of the QD. The significance of this work is that real-time volumetric temperature information will prove a more robust tool for use

  16. The past, present and future of minimally invasive therapy in urology: a review and speculative outlook.

    Science.gov (United States)

    Rassweiler, Jens; Rassweiler, Marie-Claire; Kenngott, Hannes; Frede, Thomas; Michel, Maurice-Stephan; Alken, Peter; Clayman, Ralph

    2013-08-01

    to determine the pathohistological pattern of the tumour to decide whether the patient requires removal, ablation or active surveillance. Management of localized prostate cancer underwent significant changes as well. 25 years ago open retropubic nerve-sparing radical prostatectomy was introduced as the optimal option for effective treatment of the cancer providing minimal side-effects. Basically, the same operation is performed today, but with robot-assisted laparoscopic techniques providing 7-DOF instruments, 3D-vision and tenfold magnification and enabling the surgeon to work in a sitting position at the console. In 25 years, prostate cancer may be managed in most cases by focal therapy and/or genetically targeting therapy. Only a few patients may still require robot-assisted removal of the entire gland. There has been a dramatic change in the management of the most frequent urologic diseases almost completely replacing open surgery by minimally invasive techniques. This was promoted by technical realisation of physical principles (shock waves, optical resolution, master-slave system) used outside of medicine. The future of medicine may lie in translational approaches individualizing the management based on genetic information and focalizing the treatment by further improvement of imaging technology.

  17. Tuberculosis contact screening and isoniazid preventive therapy in a South Indian district: operational issues for programmatic consideration.

    Science.gov (United States)

    Pothukuchi, Madhavi; Nagaraja, Sharath Burugina; Kelamane, Santosha; Satyanarayana, Srinath; Shashidhar; Babu, Sai; Dewan, Puneet; Wares, Fraser

    2011-01-01

    Under India's Revised National Tuberculosis Control Programme (RNTCP), all household contacts of sputum smear positive Pulmonary Tuberculosis (PTB) patients are screened for TB. In the absence of active TB disease, household contacts aged Isoniazid Preventive Therapy (IPT) (5 milligrams/kilogram body weight/day) for 6 months. To estimate the number of household contacts aged tablets in peripheral health centers. The reasons for non-evaluation of the remaining eligible children (n = 56, 33%) include no home visit by the health staff in 25 contacts, home visit done but not evaluated in 31 contacts. House-hold contacts in rural areas were less likely to be evaluated and initiated on IPT [risk ratio 6.65 (95% CI; 3.06-14.42)]. Contact screening and IPT implementation under routine programmatic conditions is sub-optimal. There is an urgent need to sensitize all concerned programme staff on its importance and establishment of mechanisms for rigorous monitoring.

  18. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise

    International Nuclear Information System (INIS)

    Beddar, A Sam; Suchowerska, Natalka; Law, Susan H

    2004-01-01

    Over the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, because of their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The main factor preventing this new technology from realizing its full potential in commercial applications is the maximization of signal coupling efficiency and the minimization of noise capture. A principal constituent of noise is Cerenkov radiation. This study reports the calculated capture of Cerenkov radiation by an optical fibre in the special case where the radiation is generated by a relativistic particle on the fibre axis and the fibre axis is parallel to the Cerenkov cone. The fraction of radiation captured is calculated as a function of the fibre core refractive index and the refractive index difference between the core and the cladding of the fibre for relativistic particles. This is then used to deduce the relative intensity captured for a range of fibre core refractive indices and fibre core-cladding refractive index differences. It is shown that the core refractive index has little effect on the amount of radiation captured compared to the refractive index difference. The implications of this result for the design of radiation therapy plastic scintillation dosimeters are considered

  19. Sleep disturbances in patients of liver cirrhosis with minimal hepatic encephalopathy before and after lactulose therapy.

    Science.gov (United States)

    Singh, Jatinderpal; Sharma, Barjesh Chander; Puri, Vinod; Sachdeva, Sanjeev; Srivastava, Siddharth

    2017-04-01

    Sleep disturbances are common in patients of cirrhosis with minimal hepatic encephalopathy (MHE) and affect health related quality of life (HRQOL). No study has evaluated effect of lactulose on sleep disturbances and correlation with HRQOL in patients with MHE. We assessed sleep disturbances in cirrhosis with MHE and effect of lactulose on sleep disturbances and HRQOL. One hundred patients of cirrhosis [MHE; (n = 50, age 45.3 ± 11.2 years, 45 males) no-MHE (n = 50, age 46.3 ± 10.4 years, 44 males)] were included. MHE was diagnosed with psychometric hepatic encephalopathy score (PHES) ≤ -5. All patients underwent laboratory parameters including arterial ammonia and critical flicker frequency (CFF) Sleep disturbances were measured with Pittsburgh Sleep Quality Index (PSQI), Epworth Sleepiness Scale (ESS) and polysomnography. HRQOL was measured with SF-36(v2) questionnaire. Patients with MHE were given lactulose therapy for 3 months and all the parameters were repeated. Poor quality of sleep and excessive day time sleepiness were more common in patients with MHE, compared to without MHE. With lactulose therapy there was improvement in MHE in 21 patients and arterial ammonia levels (93.74 ± 14.8 vs. 71.44 ± 18.8 μmol/L: p < 0.001), CFF (34.83 ± 3.54 vs. 39.44 ± 4.95 Hz: p < 0.001), PHES (-7.64 ± 2.1 vs. -5.58 ± 2.09: p < 0.001), PSQI (8.6 ± 3.3 vs. 5.2 ± 1.5: p < 0.001), ESS (12.52 ± 3.01 vs. 9.24 ± 2.27: p < 0.001) and HRQOL (p = 0.01). Excessive day time sleepiness and impaired sleep quality are common in patients with MHE and correlate with neuropsychiatric impairment. Improvement in MHE with lactulose also leads to improvement in sleep disturbances and HRQOL.

  20. Beam orientation optimization for intensity modulated radiation therapy using adaptive l2,1-minimization

    International Nuclear Information System (INIS)

    Jia Xun; Men Chunhua; Jiang, Steve B; Lou Yifei

    2011-01-01

    Beam orientation optimization (BOO) is a key component in the process of intensity modulated radiation therapy treatment planning. It determines to what degree one can achieve a good treatment plan in the subsequent plan optimization process. In this paper, we have developed a BOO algorithm via adaptive l 2,1 -minimization. Specifically, we introduce a sparsity objective function term into our model which contains weighting factors for each beam angle adaptively adjusted during the optimization process. Such an objective function favors a small number of beam angles. By optimizing a total objective function consisting of a dosimetric term and the sparsity term, we are able to identify unimportant beam angles and gradually remove them without largely sacrificing the dosimetric objective. In one typical prostate case, the convergence property of our algorithm, as well as how beam angles are selected during the optimization process, is demonstrated. Fluence map optimization (FMO) is then performed based on the optimized beam angles. The resulting plan quality is presented and is found to be better than that of equiangular beam orientations. We have further systematically validated our algorithm in the contexts of 5-9 coplanar beams for five prostate cases and one head and neck case. For each case, the final FMO objective function value is used to compare the optimized beam orientations with the equiangular ones. It is found that, in the majority of cases tested, our BOO algorithm leads to beam configurations which attain lower FMO objective function values than those of corresponding equiangular cases, indicating the effectiveness of our BOO algorithm. Superior plan qualities are also demonstrated by comparing DVH curves between BOO plans and equiangular plans.

  1. Cost Minimization Analysis of Antihypertensive Therapy with Captopril-Hydrochlorothiazide and Amlodipine-Hydrochlorothiazide in One of Hospitals in Bandung

    Directory of Open Access Journals (Sweden)

    Andini Faramitha

    2017-09-01

    Full Text Available The successful therapy of stage 2 hypertension can be supported by the administration of antihypertensive. Existence of various antihypertensive alternative, making pharmacoeconomics study is needed in order to have an effective and efficient therapy. Purpose of this study is to find the antihypertensive group therapy which is more efficient in cost (cost minimization which used in the treatment of stage 2 hypertension in patients at one hospital in Bandung from 2011 until 2013. This study is an observational reserach with retrospective data collection. Data retrieval is done by taking the medical records of hospitalized patients who received therapy of stage 2 hypertension antihypertensive, captopril-hydrochlorothiazide or amlodipin-hydrochlorothiazide. Components that are collected include the cost of antihypertensive, supportive therapy costs, the cost of action, administrative expenses and cost of hospitalization. The result of the study cost minimization analysis showed that the total cost of treatment with the antihypertensive captopril-hydrochlorothiazide is lower compared to amlodipin- hydrochlorothiazide, with the difference amounting to Rp126,798.

  2. Soothing the threatened brain: leveraging contact comfort with emotionally focused therapy.

    Directory of Open Access Journals (Sweden)

    Susan M Johnson

    Full Text Available Social relationships are tightly linked to health and well-being. Recent work suggests that social relationships can even serve vital emotion regulation functions by minimizing threat-related neural activity. But relationship distress remains a significant public health problem in North America and elsewhere. A promising approach to helping couples both resolve relationship distress and nurture effective interpersonal functioning is Emotionally Focused Therapy for couples (EFT, a manualized, empirically supported therapy that is strongly focused on repairing adult attachment bonds. We sought to examine a neural index of social emotion regulation as a potential mediator of the effects of EFT. Specifically, we examined the effectiveness of EFT for modifying the social regulation of neural threat responding using an fMRI-based handholding procedure. Results suggest that EFT altered the brain's representation of threat cues in the presence of a romantic partner. EFT-related changes during stranger handholding were also observed, but stranger effects were dependent upon self-reported relationship quality. EFT also appeared to increase threat-related brain activity in regions associated with self-regulation during the no-handholding condition. These findings provide a critical window into the regulatory mechanisms of close relationships in general and EFT in particular.

  3. Workshop to address gaps in regulation of minimally manipulated autologous cell therapies for homologous use in Canada.

    Science.gov (United States)

    Chisholm, Jolene; von Tigerstrom, Barbara; Bedford, Patrick; Fradette, Julie; Viswanathan, Sowmya

    2017-12-01

    In Canada, minimally manipulated autologous cell therapies for homologous use (MMAC-H) are either regulated under the practice of medicine, or as drugs or devices under the Food and Drugs Act, Food and Drug Regulations (F&DR) or Medical Device Regulations (MDR). Cells, Tissues and Organs (CTO) Regulations in Canada are restricted to minimally manipulated allogeneic products for homologous use. This leaves an important gap in the interpretation of existing regulations. The purposes of this workshop co-organized by the Stem Cell Network and the Centre for Commercialization of Regenerative Medicine (CCRM) were to discuss the current state of regulation of MMAC-H therapies in Canada and compare it with other regulatory jurisdictions, with the intent of providing specific policy recommendations to Health Canada. Participants came to a consensus on the need for well-defined common terminology between regulators and stakeholders, a common source of confusion and misinformation. A need for a harmonized national approach to oversight of facilities providing MMAC-H therapies based on existing standards, such as Canadian Standards Association (CSA), was also voiced. Facilities providing MMAC-H therapies should also participate in collection of long-term data to ensure patient safety and efficacy of therapies. Harmonization across provinces of the procedures and practices involving administration of MMAC-H would be preferred. Participants felt that devices used to process MMAC-H are adequately regulated under existing MDR. Overly prescriptive regulation will stifle innovation, whereas insufficient regulation might allow unsafe or ineffective therapies to be offered. Until a clear, balanced and explicit approach is articulated, regulatory uncertainty remains a barrier. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  4. Cost Minimization Analysis of the Use of Meropenem and Ceftazidime in Febrile Neutropenia Therapy

    Directory of Open Access Journals (Sweden)

    Rizky Abdulah

    2016-06-01

    Full Text Available Use of antibiotics is required in febrile neutropenia therapy. The variety choice on the use of antibiotics has increased the role of pharmacoeconomics study to determine the most effective and efficient antibiotic in a specific area. The purpose of this study was to investigate the lowest cost antibiotic between meropenem and ceftazidime that were used as one of febrile neutropenia treatments at one of referral hospitals in West Java province during 2011–2013. This study was a retrospective, observational and analytical study that was performed on February 2014 by collecting medical record data related to febrile neutropenia inpatient who received meropenem or ceftazidime therapy. The result showed that although it was not statistically significant, the total cost for ceftazidime therapy was IDR7,082,523, which was lower than meropenem therapy (IDR11,094,147. Hopefully, this result can assist the health professionals in the management of febrile neutropenia therapy.

  5. The new era of minimally invasive interventions for prostate cancer: robot-assisted laparoscopic radical prostatectomy and focal therapy

    Directory of Open Access Journals (Sweden)

    Schatloff O

    2011-10-01

    Full Text Available Oscar Schatloff1, Alyssa S Louis2, Uri Lindner21Global Robotics Institute, Florida Hospital Celebration Health, Celebration, FL, USA; 2Division of Urology, Department of Surgical Oncology, University Health Network, Toronto, ON, CanadaAbstract: Prostate cancer remains a common but highly treatable disease. Innovations in prostate cancer treatment have allowed a transition toward minimally invasive approaches in an attempt to avoid treatment-related morbidities. In the middle of the treatment spectrum between radical open surgeries and active surveillance lies robot-assisted laparoscopic radical prostatectomy (RALP and focal therapy (FT. This review sets out the most current information on RALP and FT (including laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, and irreversible electroporation.Keywords: PCa, RALP, FT, laser ablation, cryotherapy, high-intensity focused ultrasound, photodynamic therapy, irreversible electroporation

  6. Performance of a contact textile-based light diffuser for photodynamic therapy.

    Science.gov (United States)

    Khan, Tania; Unternährer, Merthan; Buchholz, Julia; Kaser-Hotz, Barbara; Selm, Bärbel; Rothmaier, Markus; Walt, Heinrich

    2006-03-01

    Medical textiles offer a unique contact opportunity that could provide value-added comfort, reliability, and safety for light or laser-based applications. We investigated a luminous textile diffuser for use in photodynamic therapy. Textile diffusers are produced by an embroidery process. Plastic optical fibers are bent and sewn into textile to release light by macrobending. A reflective backing is incorporated to improve surface homogeneity, intensity, and safety. Clonogenic assay (MCF-7 cells) and trypan blue exclusion (NuTu19 cells) tests were performed in vitro using 0.1μg/ml m-THPC with three textile diffusers and a standard front lens diffuser. Heating effects were studied in solution and on human skin. PDT application in vivo was performed with the textile diffuser on equine sarcoids (three animals, 50mW/cm(2), 10-20J) and eight research animals. Lastly, computer simulations were performed to see how the textile diffuser might work on a curved object. At low fluency rate, there is a trend for the textile diffuser to have lower survival rates than the front lens diffuser for both cell lines. The textile diffuser was observed to retain more heat over a long period (>1min). All animals tolerated the treatments well and showed similar initial reactions. The simulations showed a likely focusing effect in a curved geometry. The initial feasibility and application using a textile-based optical diffuser has been demonstrated. Possibilities that provide additional practical advantages of the textile diffuser are discussed.

  7. Transurethral microwave thermotherapy: The gold standard for minimally invasive therapies for patients with benign prostatic hyperplasia?

    NARCIS (Netherlands)

    de La Rosette, Jean J. M. C. H.; Laguna, M. Pilar; Gravas, Stavros; de Wildt, Michel J. A. M.

    2003-01-01

    From all available minimally invasive methods for the treatment of symptomatic benign prostatic hyperplasia (BPH), transurethral microwave thermotherapy (TUMT) has gained a firm position as the most attractive option. Recent research has produced innovations in high-energy TUMT, including new

  8. Technical standards for micro sensors in surgery and minimally invasive therapy.

    Science.gov (United States)

    Neuder; Dehm

    2004-04-01

    The development of medical applications is fuelled in the context of steadily growing needs and the requirement of lowering overall costs. Micro systems will have an extremely important impact on medical technology in the future. The great challenges for the wider use of micro structures in health applications are biocompatibility and mass production. Especially small and medium-sized enterprises (SMEs) need help to overcome these problems by free access to knowledge, the availability of standards and contacts to partners.

  9. MRI-guided biopsies and minimally invasive therapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Sangeet Ghai

    2015-01-01

    Full Text Available Recent advances in multiparametric magnetic resonance imaging (mp-MRI have led to a paradigm shift in the diagnosis and management of prostate cancer (PCa. Its sensitivity in detecting clinically significant cancer and the ability to localize the tumor within the prostate gland has opened up discussion on targeted diagnosis and therapy in PCa. Use of mp-MRI in conjunction with prostate-specific antigen followed by targeted biopsy allows for a better diagnostic pathway than transrectal ultrasound (TRUS biopsy and improves the diagnosis of PCa. Improved detection of PCa by mp-MRI has also opened up opportunities for focal therapy within the organ while reducing the incidence of side-effects associated with the radical treatment methods for PCa. This review discusses the evidence and techniques for in-bore MRI-guided prostate biopsy and provides an update on the status of MRI-guided targeted focal therapy in PCa.

  10. Optimization of Adjuvant Radiation in Breast Conservation Therapy: Can We Minimize without Compromise?

    International Nuclear Information System (INIS)

    Edwards-Bennett, S.M.; Correa, C.R.; Harris, E.E.

    2011-01-01

    Adjuvant breast radiation therapy after breast conservation surgery is recommended as it yields significant reduction in the risk of local recurrence, and confers a potential overall survival benefit. Although the standard breast radiation regimen has historically been delivered over 57 weeks; more novel, shorter courses of breast radiation are currently being employed, offering the advantage of more convenience and less time-commitment. Herein, we review the recent literature substantiating these abbreviated radiation treatment approaches and the methods of delivery thereof. In addition, we discuss imaged guided techniques currently being utilized to further refine the delivery of adjuvant breast radiation therapy

  11. HPV16-associated tumours: Therapy of surgical minimal residual disease with dendritic cell-based vaccines

    Czech Academy of Sciences Publication Activity Database

    Reiniš, Milan; Indrová, Marie; Mendoza, Luis; Mikyšková, Romana; Bieblová, Jana; Bubeník, Jan; Šímová, Jana

    2004-01-01

    Roč. 25, č. 4 (2004), s. 1165-1170 ISSN 1019-6439 R&D Projects: GA MZd NC7148; GA ČR GA301/04/0492; GA ČR GA301/01/0985; GA AV ČR IAA5052203 Institutional research plan: CEZ:AV0Z5052915 Keywords : HPV16 * minimal residual tumour disease * dendritic cells Subject RIV: EC - Immunology Impact factor: 3.056, year: 2004

  12. Intraperitoneal carboplatin: favorable results in women with minimal residual ovarian cancer after cisplatin therapy.

    Science.gov (United States)

    Speyer, J L; Beller, U; Colombo, N; Sorich, J; Wernz, J C; Hochster, H; Green, M; Porges, R; Muggia, F M; Canetta, R

    1990-08-01

    From August 1985 to November 1989 we conducted a trial of intraperitoneal (IP) carboplatin including a dose-escalation design in 25 women with advanced gynecologic malignancies. All had extensive prior therapy with cisplatin (median cumulative dose, 525 mg/m2). Carboplatin was administered IP in 2 L of 1.5% dextrose with a 4-hour dwell time every 4 weeks for six cycles at a starting dose of 200 mg/m2. Patients with reduced creatinine clearance (30 to 60 cc/min) were escalated more slowly than those with high (greater than 60 cc/min) clearance. Thrombocytopenia was dose-limiting and often more severe in patients with compromised renal function; there was no local drug toxicity. The median time of follow-up is 25 months. Complete responses (CRs) were documented in six of 23 assessable patients (26%) by repeat laparotomy, and an additional 11 patients (48%) had no disease evident by noninvasive restaging. Five of the CRs and six of the patients with no clinically evident disease have relapsed from 3 to 40 months after therapy. Six patients (26%) are alive and free of disease 8 to 47 (median, 20) months after therapy. IP carboplatin is effective against relapsed ovarian cancer, even after prior cisplatin therapy.

  13. Minimizing treatment planning errors in proton therapy using failure mode and effects analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yuanshui, E-mail: yuanshui.zheng@okc.procure.com [ProCure Proton Therapy Center, 5901 W Memorial Road, Oklahoma City, Oklahoma 73142 and Department of Physics, Oklahoma State University, Stillwater, Oklahoma 74078-3072 (United States); Johnson, Randall; Larson, Gary [ProCure Proton Therapy Center, 5901 W Memorial Road, Oklahoma City, Oklahoma 73142 (United States)

    2016-06-15

    Purpose: Failure mode and effects analysis (FMEA) is a widely used tool to evaluate safety or reliability in conventional photon radiation therapy. However, reports about FMEA application in proton therapy are scarce. The purpose of this study is to apply FMEA in safety improvement of proton treatment planning at their center. Methods: The authors performed an FMEA analysis of their proton therapy treatment planning process using uniform scanning proton beams. The authors identified possible failure modes in various planning processes, including image fusion, contouring, beam arrangement, dose calculation, plan export, documents, billing, and so on. For each error, the authors estimated the frequency of occurrence, the likelihood of being undetected, and the severity of the error if it went undetected and calculated the risk priority number (RPN). The FMEA results were used to design their quality management program. In addition, the authors created a database to track the identified dosimetric errors. Periodically, the authors reevaluated the risk of errors by reviewing the internal error database and improved their quality assurance program as needed. Results: In total, the authors identified over 36 possible treatment planning related failure modes and estimated the associated occurrence, detectability, and severity to calculate the overall risk priority number. Based on the FMEA, the authors implemented various safety improvement procedures into their practice, such as education, peer review, and automatic check tools. The ongoing error tracking database provided realistic data on the frequency of occurrence with which to reevaluate the RPNs for various failure modes. Conclusions: The FMEA technique provides a systematic method for identifying and evaluating potential errors in proton treatment planning before they result in an error in patient dose delivery. The application of FMEA framework and the implementation of an ongoing error tracking system at their

  14. Minimal residual disease as the target for immunotherapy and gene therapy of cancer (Review)

    Czech Academy of Sciences Publication Activity Database

    Bubeník, Jan; Šímová, Jana

    2005-01-01

    Roč. 14, č. 5 (2005), s. 1377-1380 ISSN 1021-335X R&D Projects: GA MZd(CZ) NR7807; GA MZd(CZ) NR8004; GA ČR(CZ) GA301/04/0492 Institutional research plan: CEZ:AV0Z50520514 Keywords : residual tumour disease * gene therapy * cytokines Subject RIV: EC - Immunology Impact factor: 1.572, year: 2005

  15. Minimizing treatment planning errors in proton therapy using failure mode and effects analysis

    International Nuclear Information System (INIS)

    Zheng, Yuanshui; Johnson, Randall; Larson, Gary

    2016-01-01

    Purpose: Failure mode and effects analysis (FMEA) is a widely used tool to evaluate safety or reliability in conventional photon radiation therapy. However, reports about FMEA application in proton therapy are scarce. The purpose of this study is to apply FMEA in safety improvement of proton treatment planning at their center. Methods: The authors performed an FMEA analysis of their proton therapy treatment planning process using uniform scanning proton beams. The authors identified possible failure modes in various planning processes, including image fusion, contouring, beam arrangement, dose calculation, plan export, documents, billing, and so on. For each error, the authors estimated the frequency of occurrence, the likelihood of being undetected, and the severity of the error if it went undetected and calculated the risk priority number (RPN). The FMEA results were used to design their quality management program. In addition, the authors created a database to track the identified dosimetric errors. Periodically, the authors reevaluated the risk of errors by reviewing the internal error database and improved their quality assurance program as needed. Results: In total, the authors identified over 36 possible treatment planning related failure modes and estimated the associated occurrence, detectability, and severity to calculate the overall risk priority number. Based on the FMEA, the authors implemented various safety improvement procedures into their practice, such as education, peer review, and automatic check tools. The ongoing error tracking database provided realistic data on the frequency of occurrence with which to reevaluate the RPNs for various failure modes. Conclusions: The FMEA technique provides a systematic method for identifying and evaluating potential errors in proton treatment planning before they result in an error in patient dose delivery. The application of FMEA framework and the implementation of an ongoing error tracking system at their

  16. A prospective study of the effects of radioiodine therapy for hyperthyroidism in patients with minimally active graves' ophthalmopathy.

    Science.gov (United States)

    Perros, Petros; Kendall-Taylor, Pat; Neoh, Chris; Frewin, Sarah; Dickinson, Jane

    2005-09-01

    Radioiodine is an effective and safe treatment for hyperthyroidism but has been implicated as a risk factor for deterioration or new presentation of Graves' ophthalmopathy (GO). Prophylactic glucocorticoids appear to prevent this effect. The objective of this study was to document the course of GO after radioiodine therapy. This was a prospective observational study. Patients were assessed at baseline and 2, 4, 6, and 12 months after radioiodine therapy. The study was conducted at a tertiary referral center. Seventy-two GO patients with minimally active eye disease participated in the study. A fixed dose of radioiodine was administered. T(4) was commenced 2 wk later to prevent hypothyroidism. Change in activity and severity of GO were analyzed. Exophthalmometer readings, the width of the palpebral aperture, diplopia scores, and the clinical activity score improved significantly. By clinically significant criteria, the eye disease improved in four patients (transiently in three of the four cases), most likely attributable to the natural course of the disease. No patient's eyes deteriorated. Radioiodine is not associated with deterioration of GO in patients with minimally active eye disease when postradioiodine hypothyroidism is prevented.

  17. Intersession Telephone Contact with Individuals Diagnosed with Borderline Personality Disorder: Lessons from Dialectical Behavior Therapy

    Science.gov (United States)

    Ben-Porath, Denise D.

    2004-01-01

    Therapists often struggle with managing intersession contact with clients diagnosed with borderline personality disorder, particularly when dangerous and life-threatening symptoms are communicated (Gunderson, 1996). Difficulties have arisen, in part, because previous phone contacts with this population have failed to recognize the importance of…

  18. The effect of UV-blocking contact lenses as a therapy for canine chronic superficial keratitis.

    Science.gov (United States)

    Denk, Nora; Fritsche, Jens; Reese, Sven

    2011-05-01

    To evaluate the effect of UV-blocking soft contact lenses in treatment for chronic superficial keratitus (CSK). Twenty six dogs with CSK were treated continuously with UV-blocking contact lenses for 6 months. A contact lens was placed on one eye of each dog; the other eye remained without a lens as a control eye. After this primary study, five of the dogs were further treated and they wore then contact lenses in both eyes. Continuously, all patients were concurrently treated topically with cyclosporine. The contact lenses were changed every 4 weeks and an ophthalmic examination performed. Evaluation criteria included corneal alterations as pigmentation, edema, pannus and vascularization. To determine the transmittance characteristics of the contact lenses before and after use, 32 contact lenses were measured with a UV-vis-NIR spectrophotometer. Pigmentation increased in eyes wearing lenses and in control eyes over the evaluation period of 6 months. Corneal edema increased in the eyes wearing lenses, but remained unaffected in the control eyes. A significant difference in the incidence of pannus and the extent of corneal vascularisation could not be evaluated. Adverse effects were noted in six cases (corneal edema and vascularisation, conjunctivitis, blepharospasm). All new lenses studied reduced UV-radiation to a safe level, whereas used lenses did not maintain their transmittance characteristics. No positive effect of UV-blocking contact lenses could be proven with the study design used. © 2011 American College of Veterinary Ophthalmologists.

  19. [Minimally invasive therapy for hallux valgus with deformity of little toe varus].

    Science.gov (United States)

    Gu, Shi-Wei; Yang, Ke; Zhao, Si-Qiao; Gao, Zhan-Ao; Ma, Shun-Qian; Zhang, Wen-Qing

    2018-03-25

    To explore clinical effect of minimally corrective osteotomy for the treatment of hallux valgus with deformity of little toe varus through small incision. From January 2013 to June 2016, 168 hallux valgus patients with deformity of little toe varus were treated by minimally corrective osteotomy through small incision. Among them, 7 males and 161 females were aged from 22 to 75 years old with an average of(59.3±3.5) years old. Preoperative clinical manifestation mainly focus on red and swollen of bunion, pain around with metatarsal bones, and diagnosed as hallux valgus with deformity of little toe varus through small incision. Operative time, postoperative complications, pre and post-operative IMA(angle between the first and the second metatarsal bones), HVA (hallux valgus angle), LDA(valgus angle of the fifth metatarsal bones), MPA(valgus angle of little toe), IM4-5 (angle between the forth and the fifth metatarsal bones) and PASA(fixed angle of proximal joint), postoperative AOFAS score were used to evaluate foot function. One hundred and sixty-eight patients were followed up for 6 to 48 months with an average of (28.6±3.2) months. All wounds were healed well without infection, sinus tract and other complications. Operative time ranged from 16 to 28 min with an average of (18.3±2.1) min. IMA, HVA, LDA, MPA and IM A 4-5 were (10.1±2.1)°, (32.6±4.2)°, (6.9±2.3)°, (18.5±5.2)°, (15.1±2.9)°preoperatively, improved to (8.3±2.2)°, (10.9±2.9)°, (2.7±0.4)°, (6.5±1.6)°, (8.9±1.8)° postoperatively, and had significant differences before and after operation. While there was no difference in PASA before (9.1±2.1)°and after operation(8.7±1.9)°. AOFAS score were improved from (31.6±3.9) before operation to(83.7±5.2) after operation, but no significant difference( P >0.05). According to AOFAS score, 147 patients obtained excellent results, 13 good, 6 moderate and 2 poor. Minimally corrective osteotomy for the treatment of hallux valgus with deformity

  20. Neurophysiological and behavioral responses to music therapy in vegetative and minimally conscious states

    DEFF Research Database (Denmark)

    O'Kelly, Julian; James, L.; Palaniappan, R.

    2013-01-01

    for preferred music (p = 0.029) across the VS cohort. Two VS cases are presented with concurrent changes (p ≤ 0.05) across measures indicative of discriminatory responses to both music therapy procedures. A MCS case study highlights how more sensitive selective attention may distinguish MCS from VS. Further...... of musical stimuli on arousal, attention and emotion, irrespective of verbal or motor deficits, however, an evidence base is lacking. To address this, a neurophysiological and behavioural study was undertaken comparing EEG, heart rate variability, respiration and behavioural responses of 20 healthy subjects...... responses (p ≤ 0.05) across healthy subjects corresponding to arousal and attention in response to preferred music including concurrent increases in respiration rate with globally enhanced EEG power spectra responses across frequency bandwidths. Whilst physiological responses were heterogeneous across...

  1. New methods of minimally invasive brain modulation as therapies in psychiatry: TMS, MST, VNS and DBS.

    Science.gov (United States)

    George, Mark S

    2002-08-01

    Over the past 20 years, new methods have been developed that have allowed scientists to visualize the human brain in action. Initially positron emission tomography (PET) and now functional magnetic resonance imaging (fMRI) are causing a paradigm shift in psychiatry and the neurosciences. Psychiatry is abandoning the pharmacological model of 'brain as soup', used for much of the past 20 years. Instead, there is new realization that both normal and abnormal behavior arise from chemical processes that occur within parallel distributed networks in specific brain regions. Many of these pathological circuits are becoming well characterized, in disorders ranging from Parkinson's disease, to obsessive-compulsive disorder, to depression. Most recently, there has been an explosion of new techniques that allow for direct stimulation of these brain circuits, without the need for open craniotomy and neurosurgical ablation. The techniques include transcranial magnetic stimulation (TMS), magnetic seizure therapy (MST), vagus nerve stimulation (VNS), and deep brain stimulation (DBS). This review will describe these new tools, and overview their current and future potential for research and clinical neuropsychiatric use. The psychiatry of the future will be better grounded in a firm understanding of neuroanatomy and neurophysiology (as well as pharmacology). These brain stimulation tools, or their next iterations, will play an ever-larger role in clinical neuropsychiatric practice.

  2. Determination of the minimal phototoxic dose and colorimetry in psoralen plus ultraviolet A radiation therapy.

    Science.gov (United States)

    Kraemer, Cristine Kloeckner; Menegon, Dóris Baratz; Cestari, Tania Ferreira

    2005-10-01

    The use of an adequate initial dose of ultraviolet A (UVA) radiation for photochemotherapy is important to prevent burns secondary to overdosage, meanwhile avoiding a reduced clinical improvement and long-term risks secondary to underdosage. The ideal initial dose of UVA can be achieved based on the phototype and the minimal phototoxic dose (MPD). The objective measurement of constitutive skin color (colorimetry) is another method commonly used to quantify the erythematous skin reaction to ultraviolet radiation exposure. The aim of this study was to determine variations in MPD and constitutional skin color (coordinate L(*)) within different phototypes in order to establish the best initial dose of UVA radiation for photochemotherapy patients. Thirty-six patients with dermatological conditions and 13 healthy volunteers were divided into five groups according to phototype. Constitutional skin color of the infra-axillary area was assessed by colorimetry. The infra-axillary area was subsequently divided into twelve 1.5 cm(2) regions to determine the MPD; readings were performed 72 h after oral administration of 8-methoxypsoralen (MOP) followed by exposure of the demarcated regions to increasing doses of UVA. The majority of the participants were women (73.5%) and their mean age was 38.8 years. The MPD ranged from 4 to 12 J/cm(2) in phototypes II and III; from 10 to 18 J/cm(2) in type IV; from 12 to 24 J/cm(2) in type V and from 18 to 32 J/cm(2) in type VI. The analysis of colorimetric values (L(*) coordinate) and MPD values allowed the definition of three distinctive groups of individuals composed by phototypes II and III (group 1), types IV and V (group 2), and phototype VI (group 3). MPD and L(*) coordinate showed variation within the same phototype and superposition between adjacent phototypes. The values of the L(*) coordinate and the MPD lead to the definition of three distinct sensitivity groups: phototypes II and III, IV and V and type VI. Also, the MPD values

  3. Spectral electroencephalogram in liver cirrhosis with minimal hepatic encephalopathy before and after lactulose therapy.

    Science.gov (United States)

    Singh, Jatinderpal; Sharma, Barjesh Chander; Maharshi, Sudhir; Puri, Vinod; Srivastava, Siddharth

    2016-06-01

    Minimal hepatic encephalopathy (MHE) represents the mildest form of hepatic encephalopathy. Spectral electroencephalogram (sEEG) analysis improves the recognition of MHE by decreasing inter-operator variability and providing quantitative parameters of brain dysfunction. We compared sEEG in patients with cirrhosis with and without MHE and the effects of lactulose on sEEG in patients with MHE. One hundred patients with cirrhosis (50 with and 50 without MHE) were enrolled. Diagnosis of MHE was based on psychometric hepatic encephalopathy score (PHES) of ≤ -5. Critical flicker frequency, model of end-stage liver disease score, and sEEG were performed at baseline in all patients. The spectral variables considered were the mean dominant frequency (MDF) and relative power in beta, alpha, theta, and delta bands. Patients with MHE were given 3 months of lactulose, and all parameters were repeated. Spectral electroencephalogram analysis showed lower MDF (7.8 ± 1.7 vs 8.7 ± 1.3 Hz, P < 0.05) and higher theta relative power (34.29 ± 4.8 vs 24 ± 6.7%, P = 001) while lower alpha relative power (28.6 ± 4.0 vs 33.5 ± 5.3%, P = .001) in patients with MHE than in patients without MHE. With theta relative power, sensitivity 96%, specificity 84%, and accuracy of 90% were obtained for diagnosis of MHE. After lactulose treatment, MHE improved in 21 patients, and significant changes were seen in MDF (7.8 ± 0.5 vs 8.5 ± 0.6), theta (34.2 ± 4.8 vs 23.3 ± 4.1%), alpha (28.6 ± 4.0 vs 35.5 ± 4.5%), and delta relative power (13.7 ± 3.5 vs 17.0 ± 3.3%) after treatment (P ≤ 0.05). Spectral EEG is a useful objective and quantitative tool for diagnosis and to assess the response to treatment in patients with cirrhosis with MHE. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  4. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  5. Patient with vascular disease: diagnosis and minimally invasive therapy. Which techniques for which disease?

    International Nuclear Information System (INIS)

    Kauffmann, G.W.; Grenacher, L.; Bahner, M.L.; Hess, T.; Richter, G.M.

    2001-01-01

    The non-invasive imaging modalities, color coded duplex sonography (CCDS), magnetic resonance tomography (MRT), and computed tomography (CT), have pushed conventional angiography out of most diagnostic fields. The experienced user will achieve fast, reliable answers with CCDS in dedicated clinical settings. MRT as well as CT are concurring imaging modalities for the most appropriate diagnostic answer. Not only pure image quality, but also patient management, and availability play a major role. Catheter based angiography will in the future still play a role in mesenteric ischemia (nonocclusive disease) and for imaging of very small vessel pathology, e.g. on panarteriitis nodosa. At the moment, peripheral leg run-offs are still best performed with conventional angiography, nevertheless, MR as well as CT seem to have the ability to perform diagnostic procedures. Ongoing studies will allow a solid judgement in the near future. The true value of catheter angiography is in the direct assessment, planning, and performance of interventional procedures, e.g. catheter based obliteration or revascularization. Implantation of stent devices and a whole range of different mechanical and pharmacological revascularization procedures have improved the interventional management of vascular stenoses and occlusions. The interventional radiologist is treating physician in the classical sense in this setting. Acute bleeding episodes, e.g. in the brain, thorax, abdomen, or pelvis, are best imaged with computed tomography. Conventional angiography still plays a major diagnostic and therapeutic role in bleeding into preformed cavities, such as the bile ducts or the intestine. In this setting, all available information including CT scans should be valued. For complex therapeutic regimens in oncology or in pure palliative situations, angiographic diagnosis followed by embolization and/or ablation therapy is established. (orig.) [de

  6. MO-E-BRE-01: Determination, Minimization and Communication of Uncertainties in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Van Dyk, J; Palta, J; Bortfeld, T; Mijnheer, B [Western University, London, ON (United Kingdom)

    2014-06-15

    Medical Physicists have a general understanding of uncertainties in the radiation treatment process, both with respect to dosimetry and geometry. However, there is a desire to be more quantitative about uncertainty estimation. A recent International Atomic Energy Agency (IAEA) report (about to be published) recommends that we should be as “accurate as reasonably achievable, technical and biological factors being taken into account”. Thus, a single recommendation as a goal for accuracy in radiation therapy is an oversimplification. That report also suggests that individual clinics should determine their own level of uncertainties for their specific treatment protocols. The question is “how do we implement this in clinical practice”? AAPM Monograph 35 (2011 AAPM Summer School) addressed many specific aspects of uncertainties in each of the steps of a course of radiation treatment. The intent of this symposium is: (1) to review uncertainty considerations in the entire radiation treatment process including uncertainty determination for each step and uncertainty propagation for the total process, (2) to consider aspects of robust optimization which optimizes treatment plans while protecting them against uncertainties, and (3) to describe various methods of displaying uncertainties and communicating uncertainties to the relevant professionals. While the theoretical and research aspects will also be described, the emphasis will be on the practical considerations for the medical physicist in clinical practice. Learning Objectives: To review uncertainty determination in the overall radiation treatment process. To consider uncertainty modeling and uncertainty propagation. To highlight the basic ideas and clinical potential of robust optimization procedures to generate optimal treatment plans that are not severely affected by uncertainties. To describe methods of uncertainty communication and display.

  7. MO-E-BRE-01: Determination, Minimization and Communication of Uncertainties in Radiation Therapy

    International Nuclear Information System (INIS)

    Van Dyk, J; Palta, J; Bortfeld, T; Mijnheer, B

    2014-01-01

    Medical Physicists have a general understanding of uncertainties in the radiation treatment process, both with respect to dosimetry and geometry. However, there is a desire to be more quantitative about uncertainty estimation. A recent International Atomic Energy Agency (IAEA) report (about to be published) recommends that we should be as “accurate as reasonably achievable, technical and biological factors being taken into account”. Thus, a single recommendation as a goal for accuracy in radiation therapy is an oversimplification. That report also suggests that individual clinics should determine their own level of uncertainties for their specific treatment protocols. The question is “how do we implement this in clinical practice”? AAPM Monograph 35 (2011 AAPM Summer School) addressed many specific aspects of uncertainties in each of the steps of a course of radiation treatment. The intent of this symposium is: (1) to review uncertainty considerations in the entire radiation treatment process including uncertainty determination for each step and uncertainty propagation for the total process, (2) to consider aspects of robust optimization which optimizes treatment plans while protecting them against uncertainties, and (3) to describe various methods of displaying uncertainties and communicating uncertainties to the relevant professionals. While the theoretical and research aspects will also be described, the emphasis will be on the practical considerations for the medical physicist in clinical practice. Learning Objectives: To review uncertainty determination in the overall radiation treatment process. To consider uncertainty modeling and uncertainty propagation. To highlight the basic ideas and clinical potential of robust optimization procedures to generate optimal treatment plans that are not severely affected by uncertainties. To describe methods of uncertainty communication and display

  8. Minimally invasive liver resection to obtain tumor-infiltrating lymphocytes for adoptive cell therapy in patients with metastatic melanoma

    Directory of Open Access Journals (Sweden)

    Alvarez-Downing Melissa M

    2012-06-01

    Full Text Available Abstract Background Adoptive cell therapy (ACT with tumor-infiltrating lymphocytes (TIL in patients with metastatic melanoma has been reported to have a 56% overall response rate with 20% complete responders. To increase the availability of this promising therapy in patients with advanced melanoma, a minimally invasive approach to procure tumor for TIL generation is warranted. Methods A feasibility study was performed to determine the safety and efficacy of laparoscopic liver resection to generate TIL for ACT. Retrospective review of a prospectively maintained database identified 22 patients with advanced melanoma and visceral metastasis (AJCC Stage M1c who underwent laparoscopic liver resection between 1 October 2005 and 31 July 2011. The indication for resection in all patients was to receive postoperative ACT with TIL. Results Twenty patients (91% underwent resection utilizing a closed laparoscopic technique, one required hand-assistance and another required conversion to open resection. Median intraoperative blood loss was 100 mL with most cases performed without a Pringle maneuver. Median hospital stay was 3 days. Three (14% patients experienced a complication from resection with no mortality. TIL were generated from 18 of 22 (82% patients. Twelve of 15 (80% TIL tested were found to have in vitro tumor reactivity. Eleven patients (50% received the intended ACT. Two patients were rendered no evidence of disease after surgical resection, with one undergoing delayed ACT with generated TIL after relapse. Objective tumor response was seen in 5 of 11 patients (45% who received TIL, with one patient experiencing an ongoing complete response (32+ months. Conclusions Laparoscopic liver resection can be performed with minimal morbidity and serve as an effective means to procure tumor to generate therapeutic TIL for ACT to patients with metastatic melanoma.

  9. Minimizing the number of segments in a delivery sequence for intensity-modulated radiation therapy with a multileaf collimator

    International Nuclear Information System (INIS)

    Dai Jianrong; Zhu Yunping

    2001-01-01

    This paper proposes a sequencing algorithm for intensity-modulated radiation therapy with a multileaf collimator in the static mode. The algorithm aims to minimize the number of segments in a delivery sequence. For a machine with a long verification and recording overhead time (e.g., 15 s per segment), minimizing the number of segments is equivalent to minimizing the delivery time. The proposed new algorithm is based on checking numerous candidates for a segment and selecting the candidate that results in a residual intensity matrix with the least complexity. When there is more than one candidate resulting in the same complexity, the candidate with the largest size is selected. The complexity of an intensity matrix is measured in the new algorithm in terms of the number of segments in the delivery sequence obtained by using a published algorithm. The beam delivery efficiency of the proposed algorithm and the influence of different published algorithms used to calculate the complexity of an intensity matrix were tested with clinical intensity-modulated beams. The results show that no matter which published algorithm is used to calculate the complexity of an intensity matrix, the sequence generated by the algorithm proposed here is always more efficient than that generated by the published algorithm itself. The results also show that the algorithm used to calculate the complexity of an intensity matrix affects the efficiency of beam delivery. The delivery sequences are frequently most efficient when the algorithm of Bortfeld et al. is used to calculate the complexity of an intensity matrix. Because no single variation is most efficient for all beams tested, we suggest implementing multiple variations of our algorithm

  10. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  11. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins

    International Nuclear Information System (INIS)

    Buecker, A.; Gross-Fengels, W.; Haage, P.; Huppert, P.; Landwehr, P.; Loose, R.; Reimer, P.; Tacke, J.; Vorwerk, D.; Fischer, J.

    2012-01-01

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  12. Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery

    International Nuclear Information System (INIS)

    Li Kaile; Dai Jianrong; Ma Lijun

    2004-01-01

    Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment between segments. We implemented and demonstrated our method for multiple clinical cases. We compared the results of our method with the results from exhaustive search method. We found that our solution without leaf end abutment produced equivalent results to the unconstrained solutions in terms of minimum total monitor units and minimum number of leaf segments. We conclude that the leaf end abutment fields can be avoided without affecting the efficiency of segmental IMRT delivery. The major strength of our method is its simplicity and high computing speed. This potentially provides a useful means for generating segmental IMRT fields that require high spatial resolution or complex intensity distributions

  13. A prospective controlled study: Minimally invasive stereotactic puncture therapy versus conventional craniotomy in the treatment of acute intracerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Tang Yuping

    2011-06-01

    Full Text Available Abstract Background Spontaneous intracerebral hemorrhage (ICH is a devastating form of stroke with the high mortality twofold to sixfold higher than that for ischemic stroke. But the treatment of haematomas within the basal ganglia continues to be a matter of debate among neurologists and neurosurgeons. The purpose of this study is to judge the clinical value of minimally invasive stereotactic puncture therapy (MISPT on acute ICH. Methods A prospective controlled study was undertaken. The clinical trial was in compliance with the WMA Declaration of Helsinki - Ethical Principles for Medical Research Involving Human Subjects. According to the enrollment criterion, there were 168 acute ICH cases analyzed, of which 90 cases were performed by MISPT ( MISPT group, MG and 78 cases by Conventional craniotomy (CC group, CG, by means of compare of Glasgow Coma Scale(GCS score, postoperative complications(PC and rebleeding incidence(RI, moreover, long-term outcome of 1 year postoperation judged by Glasgow Outcome Scale (GOS, Barthel Index (BI, modified Rankin Scale (mRS and case fatality(CF. Results MG patients showed obvious amelioration in GCS score compared with that of CG. The total incidence of PC in MG decreased obviously compared with that of CG. The incidences of rebleeding in MG and CG were 10.0% and 15.4% respectively. There was no obvious difference between CFs of MG and CG. For three parameters representing long-term outcome, the GOS, BI and mRS in MG were ameliorated significantly than that of CG. Conclusion These data suggested that the advantage of MISPT was displayed in minute trauma and safety, and seemed to be feasible and to had a trend towards improved long-term outcome. Trial Registration The Australian New Zealand Clinical Trials Registry (ANZCTR, the registration number:ACTRN12610000945022.

  14. Quantification and Minimization of Uncertainties of Internal Target Volume for Stereotactic Body Radiation Therapy of Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ge Hong [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Department of Radiation Oncology, Henan Cancer Hospital, the Affiliated Cancer Hospital of Zhengzhou University, Henan (China); Cai Jing; Kelsey, Chris R. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States); Yin Fangfang, E-mail: fangfang.yin@duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina (United States)

    2013-02-01

    Purpose: To quantify uncertainties in delineating an internal target volume (ITV) and to understand how these uncertainties may be individually minimized for stereotactic body radiation therapy (SBRT) of early stage non-small cell lung cancer (NSCLC). Methods and Materials: Twenty patients with NSCLC who were undergoing SBRT were imaged with free-breathing 3-dimensional computed tomography (3DCT) and 10-phase 4-dimensional CT (4DCT) for delineating gross tumor volume (GTV){sub 3D} and ITV{sub 10Phase} (ITV3). The maximum intensity projection (MIP) CT was also calculated from 10-phase 4DCT for contouring ITV{sub MIP} (ITV1). Then, ITV{sub COMB} (ITV2), ITV{sub 10Phase+GTV3D} (ITV4), and ITV{sub 10Phase+ITVCOMB} (ITV5) were generated by combining ITV{sub MIP} and GTV{sub 3D}, ITV{sub 10phase} and GTV{sub 3D}, and ITV{sub 10phase} and ITV{sub COMB}, respectively. All 6 volumes (GTV{sub 3D} and ITV1 to ITV5) were delineated in the same lung window by the same radiation oncologist. The percentage of volume difference (PVD) between any 2 different volumes was determined and was correlated to effective tumor diameter (ETD), tumor motion ranges, R{sub 3D}, and the amplitude variability of the recorded breathing signal (v) to assess their volume variations. Results: The mean (range) tumor motion (R{sub SI}, R{sub AP}, R{sub ML}, and R{sub 3D}) and breathing variability (v) were 7.6 mm (2-18 mm), 4.0 mm (2-8 mm), 3.3 mm (0-7.5 mm), 9.9 mm (4.1-18.7 mm), and 0.17 (0.07-0.37), respectively. The trend of volume variation was GTV{sub 3D}

  15. Treatment of minimal residual disease after surgery or chemotherapy in mice carrying HPV16-associated tumours: cytokine and gene therapy with IL-2 and GM-CSF

    Czech Academy of Sciences Publication Activity Database

    Mikyšková, Romana; Indrová, Marie; Šímová, Jana; Jandlová, Táňa; Bieblová, Jana; Jinoch, P.; Bubeník, Jan; Vonka, V.

    2004-01-01

    Roč. 24, č. 1 (2004), s. 161-167 ISSN 1019-6439 R&D Projects: GA MZd NC7148; GA MZd NC7552; GA ČR GA301/01/0985 Institutional research plan: CEZ:AV0Z5052915 Keywords : HPV16 * gene therapy * minimal residual tumour disease Subject RIV: FD - Oncology ; Hematology Impact factor: 3.056, year: 2004

  16. Effect of minimally invasive evacuation of hematoma combined with Xingnaojing therapy on neurological function injury and cytokine level in patients with hypertensive cerebral hemorrhagen

    OpenAIRE

    Yong-Feng Li; Wei Li

    2017-01-01

    Objective: To study the effect of minimally invasive evacuation of hematoma combined with Xingnaojing therapy on neurological function damage and cytokine level in patients with hypertensive cerebral hemorrhage. Methods: A total of 80 patients with hypertensive cerebral hemorrhage treated in our hospital between June 2010 and September 2015 were selected as the research subjects, the treatment methods and test results were reviewed, and then they were divided into the control g...

  17. Nonsurgical endodontic therapy along with minimal invasive treatment utilizing Bhasker's hypothesis for the management of infected radicular cystic lesion: A rare case report

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Salaria

    2016-01-01

    Full Text Available Radicular cyst (RC is the most common odontogenic cyst of inflammatory origin affecting the jaws; involves the roots of the carious or traumatic non-vital tooth. Different therapeutic modalities, such as nonsurgical endodontic therapy or surgical enucleation with primary closure, decompression etc., were proposed for the management of such lesions. Presenting a case of a 28-year-old otherwise healthy male patient who reported with pain and swelling with respect to tooth #41, 31. Diagnosis of infected RC at a rare location was established on the basis of clinical, radiographical and fine needle aspiration cytological examination. Looking after the clinical characteristics, origin, extension, size of cystic lesion and patient cooperation; nonsurgical endodontic therapy utilizing Bhasker's hypothesis was opted. One year post-operative result suggested that nonsurgical endodontic therapy along with minimally invasive treatment utilizing Bhasker's hypothesis is an effective tool to transform infected radicular cystic lesion to healthy periapical periodontal tissue.

  18. Simultaneous minimization of leaf travel distance and tongue-and-groove effect for segmental intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Dai Jianrong; Que, William

    2004-01-01

    This paper introduces a method to simultaneously minimize the leaf travel distance and the tongue-and-groove effect for IMRT leaf sequences to be delivered in segmental mode. The basic idea is to add a large enough number of openings through cutting or splitting existing openings for those leaf pairs with openings fewer than the number of segments so that all leaf pairs have the same number of openings. The cutting positions are optimally determined with a simulated annealing technique called adaptive simulated annealing. The optimization goal is set to minimize the weighted summation of the leaf travel distance and tongue-and-groove effect. Its performance was evaluated with 19 beams from three clinical cases; one brain, one head-and-neck and one prostate case. The results show that it can reduce the leaf travel distance and (or) tongue-and-groove effect; the reduction of the leaf travel distance reaches its maximum of about 50% when minimized alone; the reduction of the tongue-and-groove reaches its maximum of about 70% when minimized alone. The maximum reduction in the leaf travel distance translates to a 1 to 2 min reduction in treatment delivery time per fraction, depending on leaf speed. If the method is implemented clinically, it could result in significant savings in treatment delivery time, and also result in significant reduction in the wear-and-tear of MLC mechanics

  19. TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

    International Nuclear Information System (INIS)

    Li, H; Zhang, X; Zhu, X; Li, Y

    2014-01-01

    Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy

  20. Novel minimally invasive chemoradiation therapy combined with biliary stenting for multidisciplinary approach to unresectable bile duct carcinoma

    International Nuclear Information System (INIS)

    Suzuki, Masanori; Sato, Takeaki; Umino, Noriaki

    2001-01-01

    Multidisciplinary treatment is a useful approach to unresectable non-metastatic bile duct carcinoma with invasion of the hepatic artery and portal vein. The authors developed a multidisciplinary treatment consisting of chemoradiation therapy combined with intraluminal bile duct irradiation plus external irradiation and systemic or local chemotherapy. The aim of this regimen was to improve the ability to locally control bile duct carcinoma by intraluminal irradiation and to shorten the treatment period compared to external irradiation therapy alone. According to the treatment schedule whole-body irradiation is performed first and followed by systemic administration of 5-fluorouracil (5-FU, 600 mg/m 2 /day) and cisplatin (CDDP, 10 mg/m 2 /day) after biliary stenting plus simultaneously intraluminal irradiation (8 Gy/week x 3, total 24 Gy) administered with 192 Ir-RALS (Remote After Loading System). Two novel types of applicators specifically designed by the authors for intraluminal radiation of the bile duct were improved. The authors have used this multidisciplinary approach to treat 3 patients with bile duct carcinoma. Its application has shortened the course of multidisciplinary therapy to about 6 weeks, and the patients have surviveed more than 6-8 months without recurrence. (K.H.)

  1. Minimal surfaces

    CERN Document Server

    Dierkes, Ulrich; Sauvigny, Friedrich; Jakob, Ruben; Kuster, Albrecht

    2010-01-01

    Minimal Surfaces is the first volume of a three volume treatise on minimal surfaces (Grundlehren Nr. 339-341). Each volume can be read and studied independently of the others. The central theme is boundary value problems for minimal surfaces. The treatise is a substantially revised and extended version of the monograph Minimal Surfaces I, II (Grundlehren Nr. 295 & 296). The first volume begins with an exposition of basic ideas of the theory of surfaces in three-dimensional Euclidean space, followed by an introduction of minimal surfaces as stationary points of area, or equivalently

  2. What Is Music Therapy?

    Science.gov (United States)

    American Music Therapy Association Home Contact News Help/FAQ Members Only Login About Music Therapy & AMTA What is Music Therapy? Definition and ... is Music Therapy? Print Email Share What is Music Therapy What is Music Therapy? Music Therapy is ...

  3. Language Contact.

    Science.gov (United States)

    Nelde, Peter Hans

    1995-01-01

    Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)

  4. Gastroesophageal reflux disease as an etiology of sleep disturbance in subjects with insomnia and minimal reflux symptoms: a pilot study of prevalence and response to therapy.

    Science.gov (United States)

    Shaheen, Nicholas J; Madanick, Ryan D; Alattar, Maha; Morgan, Douglas R; Davis, Paris H; Galanko, Joseph A; Spacek, Melissa B; Vaughn, Bradley V

    2008-06-01

    Gastroesophageal reflux disease (GERD) is a well-recognized cause of impaired sleep in patients with frequent GERD symptoms, as well as those with sleep apnea. GERD's role in sleep disturbance of minimally symptomatic patients with poor sleep quality is less clear. We aimed to define the prevalence of GERD-related sleep disturbance in minimally-symptomatic subjects with demonstrated insomnia, and to assess the changes in sleep efficiency in these subjects after vigorous acid suppression. We recruited subjects aged 18-75 years reporting at least 6 months of insomnia, and sleep difficulty at least three nights per week. Subjects with a BMI > 30, a history of snoring or ongoing use of proton pump inhibitor or H2 receptor antagonist were excluded. Subjects underwent concurrent sleep study with dual channel 24-h pH study. Sleep efficiency, defined as the percentage of time after sleep initiation that the subject actually slept, and spontaneous arousal index, defined as the number of arousals per hour, were calculated. Those with a sleep study demonstrating poor sleep quality (sleep efficiency of 10 arousals/h for those aged 15 for those who were 45 or older) and no obstructive sleep apnea were treated with rabeprazole 20 mg PO BID x 14 days. After 14 days, the subjects underwent repeat sleep study with pH monitoring. The GERD Symptom Assessment Scale (GSAS), the Epworth Sleepiness Scale (ESS) and the Functional Outcomes of Sleep Questionnaire (FOSQ) were administered to subjects at study inception and after 2 weeks of therapy. Twenty-four subjects reporting insomnia were enrolled, and 20 met criteria for disordered sleep and no OSA. Seventeen completed both the first and second studies, and 16 were adequate for analysis. Baseline GSAS demonstrated trivial or no reflux symptoms in the cohort (no subject scored > 8 out of 45 on GSAS, corresponding to a median rating of reflux symptoms of "not at all"). Four of 16 subjects (25%) demonstrated abnormal pH studies at baseline

  5. Clinical impact of minimal residual disease in children with different subtypes of acute lymphoblastic leukemia treated with Response-Adapted therapy.

    Science.gov (United States)

    Pui, C-H; Pei, D; Raimondi, S C; Coustan-Smith, E; Jeha, S; Cheng, C; Bowman, W P; Sandlund, J T; Ribeiro, R C; Rubnitz, J E; Inaba, H; Gruber, T A; Leung, W H; Yang, J J; Downing, J R; Evans, W E; Relling, M V; Campana, D

    2017-02-01

    To determine the clinical significance of minimal residual disease (MRD) in patients with prognostically relevant subtypes of childhood acute lymphoblastic leukemia (ALL), we analyzed data from 488 patients treated in St Jude Total Therapy Study XV with treatment intensity based mainly on MRD levels measured during remission induction. MRD levels on day 19 predicted treatment outcome for patients with hyperdiploid >50 ALL, National Cancer Institute (NCI) standard-risk B-ALL or T-cell ALL, while MRD levels on day 46 were prognostic for patients with NCI standard-risk or high-risk B-ALL. Patients with t(12;21)/(ETV6-RUNX1) or hyperdiploidy >50 ALL had the best prognosis; those with a negative MRD on day 19 had a particularly low risk of relapse: 1.9% and 3.8%, respectively. Patients with NCI high-risk B-ALL or T-cell ALL had an inferior outcome; even with undetectable MRD on day 46, cumulative risk of relapse was 12.7% and 15.5%, respectively. Among patients with NCI standard-risk B-ALL, the outcome was intermediate overall but was poor if MRD was ⩾1% on day 19 or MRD was detectable at any level on day 46. Our results indicate that the clinical impact of MRD on treatment outcome in childhood ALL varies considerably according to leukemia subtype and time of measurement.

  6. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Strother, C. [University of Wisconsin (United States)

    2016-06-15

    1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being

  7. WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

    International Nuclear Information System (INIS)

    Strother, C.

    2016-01-01

    1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being

  8. Chromosomal minimal critical regions in therapy-related leukemia appear different from those of de novo leukemia by high-resolution aCGH.

    Directory of Open Access Journals (Sweden)

    Nathalie Itzhar

    Full Text Available Therapy-related acute leukemia (t-AML, is a severe complication of cytotoxic therapy used for primary cancer treatment. The outcome of these patients is poor, compared to people who develop de novo acute leukemia (p-AML. Cytogenetic abnormalities in t-AML are similar to those found in p-AML but present more frequent unfavorable karyotypes depending on the inducting agent. Losses of chromosome 5 or 7 are observed after alkylating agents while balanced translocations are found after topoisomerase II inhibitors. This study compared t-AML to p-AML using high resolution array CGH in order to find copy number abnormalities (CNA at a higher resolution than conventional cytogenetics. More CNAs were observed in 30 t-AML than in 36 p-AML: 104 CNAs were observed with 63 losses and 41 gains (mean number 3.46 per case in t-AML, while in p-AML, 69 CNAs were observed with 32 losses and 37 gains (mean number of 1.9 per case. In primary leukemia with a previously "normal" karyotype, 18% exhibited a previously undetected CNA, whereas in the (few t-AML with a normal karyotype, the rate was 50%. Several minimal critical regions (MCRs were found in t-AML and p-AML. No common MCRs were found in the two groups. In t-AML a 40 kb deleted MCR pointed to RUNX1 on 21q22, a gene coding for a transcription factor implicated in frequent rearrangements in leukemia and in familial thrombocytopenia. In de novo AML, a 1 Mb MCR harboring ERG and ETS2 was observed from patients with complex aCGH profiles. High resolution cytogenomics obtained by aCGH and similar techniques already published allowed us to characterize numerous non random chromosome abnormalities. This work supports the hypothesis that they can be classified into several categories: abnormalities common to all AML; those more frequently found in t-AML and those specifically found in p-AML.

  9. Contact X-ray Therapy for Rectal Cancer: Experience in Centre Antoine-Lacassagne, Nice, 2002-2006

    International Nuclear Information System (INIS)

    Gerard, Jean-Pierre; Ortholan, Cecile; Benezery, Karene; Ginot, Aurelie; Hannoun-Levi, Jean-Michel; Chamorey, Emmanuel; Benchimol, Daniel; Francois, Eric

    2008-01-01

    Purpose: To report the results of using contact X-ray (CXR), which has been used in the Centre-Lacassagne since 2002 for rectal cancer. Methods and Materials: A total of 44 patients were treated between 2002 and 2006 using four distinct clinical approaches. Patients with Stage T1N0 tumors were treated with transanal local excision (TLE) and adjuvant CXR (45 Gy in three fractions) (n = 7). The 11 inoperable (or who had refused surgery) patients with Stage T2-T3 disease were treated with CXR plus external beam radiotherapy (EBRT). Those with Stage T3N0-N2 tumors were treated with preoperative CXR plus EBRT (with or without concurrent chemotherapy) followed by surgery (n = 21). Finally, the patients with Stage T2 disease were treated with CXR plus EBRT followed by TLE (n = 5). Results: The median follow-up was 25 months. In the 7 patients who underwent TLE first, no local failure was observed, and their anorectal function was good. Of the 11 inoperable patients who underwent CXR plus EBRT alone, 10 achieved local control. In the third group (preoperative CXR plus EBRT), anterior resection was performed in 16 of 21 patients. Complete sterilization of the operative specimen was seen in 4 cases (19%). No local recurrence occurred. Finally, of the 5 patients treated with CXR plus EBRT followed by TLE, a complete or near complete clinical response was observed in all. TLE with a R0 resection margin was performed in all cases. The rectum was preserved with good function in all 5 patients. Conclusion: These early results have confirmed that CXR combined with surgery (or alone with EBRT) can play a major role in the conservative and curative treatment of rectal cancer

  10. Taxonomic minimalism.

    Science.gov (United States)

    Beattle, A J; Oliver, I

    1994-12-01

    Biological surveys are in increasing demand while taxonomic resources continue to decline. How much formal taxonomy is required to get the job done? The answer depends on the kind of job but it is possible that taxonomic minimalism, especially (1) the use of higher taxonomic ranks, (2) the use of morphospecies rather than species (as identified by Latin binomials), and (3) the involvement of taxonomic specialists only for training and verification, may offer advantages for biodiversity assessment, environmental monitoring and ecological research. As such, formal taxonomy remains central to the process of biological inventory and survey but resources may be allocated more efficiently. For example, if formal Identification is not required, resources may be concentrated on replication and increasing sample sizes. Taxonomic minimalism may also facilitate the inclusion in these activities of important but neglected groups, especially among the invertebrates, and perhaps even microorganisms. Copyright © 1994. Published by Elsevier Ltd.

  11. A novel platform for minimally invasive delivery of cellular therapy as a thin layer across the subretina for treatment of retinal degeneration

    Science.gov (United States)

    Rotenstreich, Ygal; Tzameret, Adi; Kalish, Sapir E.; Belkin, Michael; Meir, Amilia; Treves, Avraham J.; Nagler, Arnon; Sher, Ifat

    2015-03-01

    Incurable retinal degenerations affect millions worldwide. Stem cell transplantation rescued visual functions in animal models of retinal degeneration. In those studies cells were transplanted in subretinal "blebs", limited number of cells could be injected and photoreceptor rescue was restricted to areas in proximity to the injection sites. We developed a minimally-invasive surgical platform for drug and cell delivery in a thin layer across the subretina and extravascular spaces of the choroid. The novel system is comprised of a syringe with a blunt-tipped needle and an adjustable separator. Human bone marrow mesenchymal stem cells (hBM-MSCs) were transplanted in eyes of RCS rats and NZW rabbits through a longitudinal triangular scleral incision. No immunosuppressants were used. Retinal function was determined by electroretinogram analysis and retinal structure was determined by histological analysis and OCT. Transplanted cells were identified as a thin layer across the subretina and extravascular spaces of the choroid. In RCS rats, cell transplantation delayed photoreceptor degeneration across the entire retina and significantly enhanced retinal functions. No retinal detachment or choroidal hemorrhages were observed in rabbits following transplantation. This novel platform opens a new avenue for drug and cell delivery, placing the transplanted cells in close proximity to the damaged RPE and retina as a thin layer, across the subretina and thereby slowing down cell death and photoreceptor degeneration, without retinal detachment or choroidal hemorrhage. This new transplantation system may increase the therapeutic effect of other cell-based therapies and therapeutic agents. This study is expected to directly lead to phase I/II clinical trials for autologous hBM-MSCs transplantation in retinal degeneration patients.

  12. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    Science.gov (United States)

    Kim, Hojin; Li, Ruijiang; Lee, Rena; Xing, Lei

    2015-03-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans.

  13. Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization

    International Nuclear Information System (INIS)

    Kim, Hojin; Li, Ruijiang; Xing, Lei; Lee, Rena

    2015-01-01

    Conventional VMAT optimizes aperture shapes and weights at uniformly sampled stations, which is a generalization of the concept of a control point. Recently, rotational station parameter optimized radiation therapy (SPORT) has been proposed to improve the plan quality by inserting beams to the regions that demand additional intensity modulations, thus formulating non-uniform beam sampling. This work presents a new rotational SPORT planning strategy based on reweighted total-variation (TV) minimization (min.), using beam’s-eye-view dosimetrics (BEVD) guided beam selection. The convex programming based reweighted TV min. assures the simplified fluence-map, which facilitates single-aperture selection at each station for single-arc delivery. For the rotational arc treatment planning and non-uniform beam angle setting, the mathematical model needs to be modified by additional penalty term describing the fluence-map similarity and by determination of appropriate angular weighting factors. The proposed algorithm with additional penalty term is capable of achieving more efficient and deliverable plans adaptive to the conventional VMAT and SPORT planning schemes by reducing the dose delivery time about 5 to 10 s in three clinical cases (one prostate and two head-and-neck (HN) cases with a single and multiple targets). The BEVD guided beam selection provides effective and yet easy calculating methodology to select angles for denser, non-uniform angular sampling in SPORT planning. Our BEVD guided SPORT treatment schemes improve the dose sparing to femoral heads in the prostate and brainstem, parotid glands and oral cavity in the two HN cases, where the mean dose reduction of those organs ranges from 0.5 to 2.5 Gy. Also, it increases the conformation number assessing the dose conformity to the target from 0.84, 0.75 and 0.74 to 0.86, 0.79 and 0.80 in the prostate and two HN cases, while preserving the delivery efficiency, relative to conventional single-arc VMAT plans

  14. Qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins; Qualifizierungsleitlinie der Deutschen Roentgengesellschaft (DRG) und der Deutschen Gesellschaft fuer Interventionelle Radiologie und minimalinvasive Therapie (DeGIR) zur Durchfuehrung interventionell-radiologischer minimalinvasiver Verfahren an Arterien und Venen

    Energy Technology Data Exchange (ETDEWEB)

    Buecker, A. [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany); Gross-Fengels, W. [Asklepiosklinik, Hamburg-Harburg (Germany); Haage, P. [Helios-Kliniken, Wuppertal (Germany); Huppert, P. [Klinikum Darmstadt (Germany); Landwehr, P. [Henriettenstiftung, Hannover (Germany); Loose, R. [Klinikum Nuernberg-Nord (Germany); Reimer, P. [Klinikum Karlsruhe (Germany); Tacke, J. [Klinikum Passau (Germany); Vorwerk, D. [Klinikum Ingolstadt (Germany); Fischer, J.

    2012-06-15

    The topics covered in the qualification guideline of the German X-ray association (DRG) und the German association for interventional radiology and minimal invasive therapy (DeGIR) for the performance of interventional-radiological minimal invasive procedures on arteries and veins are the following: Practical qualification: aorta iliac vessels and vessels in the upper and lower extremities, kidney and visceral arteries, head and neck arteries, dialysis shunts, veins and pulmonary arteries, aorta aneurysms and peripheral artery aneurysms. Knowledge acquisition concerning radiation protection: legal fundamentals, education and training, knowledge actualization and quality control, definition of the user and the procedure, competence preservation.

  15. Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hojin; Li Ruijiang; Lee, Rena; Goldstein, Thomas; Boyd, Stephen; Candes, Emmanuel; Xing Lei [Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States) and Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Ehwa University, Seoul 158-710 (Korea, Republic of); Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States); Department of Statistics, Stanford University, Stanford, California 94305-4065 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5304 (United States)

    2012-07-15

    Purpose: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem. Methods: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases. Results: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the

  16. Topological gravity with minimal matter

    International Nuclear Information System (INIS)

    Li Keke

    1991-01-01

    Topological minimal matter, obtained by twisting the minimal N = 2 supeconformal field theory, is coupled to two-dimensional topological gravity. The free field formulation of the coupled system allows explicit representations of BRST charge, physical operators and their correlation functions. The contact terms of the physical operators may be evaluated by extending the argument used in a recent solution of topological gravity without matter. The consistency of the contact terms in correlation functions implies recursion relations which coincide with the Virasoro constraints derived from the multi-matrix models. Topological gravity with minimal matter thus provides the field theoretic description for the multi-matrix models of two-dimensional quantum gravity. (orig.)

  17. Minimally Invasive Parathyroidectomy

    Directory of Open Access Journals (Sweden)

    Lee F. Starker

    2011-01-01

    Full Text Available Minimally invasive parathyroidectomy (MIP is an operative approach for the treatment of primary hyperparathyroidism (pHPT. Currently, routine use of improved preoperative localization studies, cervical block anesthesia in the conscious patient, and intraoperative parathyroid hormone analyses aid in guiding surgical therapy. MIP requires less surgical dissection causing decreased trauma to tissues, can be performed safely in the ambulatory setting, and is at least as effective as standard cervical exploration. This paper reviews advances in preoperative localization, anesthetic techniques, and intraoperative management of patients undergoing MIP for the treatment of pHPT.

  18. Shoe allergic contact dermatitis.

    Science.gov (United States)

    Matthys, Erin; Zahir, Amir; Ehrlich, Alison

    2014-01-01

    Foot dermatitis is a widespread condition, affecting men and women of all ages. Because of the location, this condition may present as a debilitating problem to those who have it. Allergic contact dermatitis involving the feet is frequently due to shoes or socks. The allergens that cause shoe dermatitis can be found in any constituent of footwear, including rubber, adhesives, leather, dyes, metals, and medicaments. The goal of treatment is to identify and minimize contact with the offending allergen(s). The lack of product information released from shoe manufacturers and the continually changing trends in footwear present a challenge in treating this condition. The aim of this study is to review the current literature on allergic contact shoe dermatitis; clinical presentation, allergens, patch testing, and management will be discussed. PubMed and MEDLINE databases were used for the search, with a focus on literature updates from the last 15 years.

  19. Adjuvant cytokine treatment of minimal residual disease after surgical therapy in mice carrying HPV16-associated tumours: Cytolytic activity of spleen cells from tumour regressors

    Czech Academy of Sciences Publication Activity Database

    Indrová, Marie; Mikyšková, Romana; Jandlová, Táňa; Vonka, V.; Bubeník, Jan; Bieblová, Jana

    2003-01-01

    Roč. 2003, č. 49 (2003), s. 217-222 ISSN 0015-5500 Institutional research plan: CEZ:AV0Z5052915 Keywords : HPV16 * gene therapy * IL-2 Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.527, year: 2003

  20. LANL Contacts

    Science.gov (United States)

    : (505) 665-3664 ethics@lanl.gov Journalist queries Communications Office (505) 667-7000 Media contacts programs and employee resources. General Employee directory Emergency communication Communications Office (505) 667-7000 Ethics & Audits Internal Audit: (505) 665-3104 Ethics Office: (505) 667-7506 Fax

  1. On mixed reality environments for minimally invasive therapy guidance: Systems architecture, successes and challenges in their implementation from laboratory to clinic

    Science.gov (United States)

    Linte, Cristian A.; Davenport, Katherine P.; Cleary, Kevin; Peters, Craig; Vosburgh, Kirby G.; Navab, Nassir; Edwards, Philip “Eddie”; Jannin, Pierre; Peters, Terry M.; Holmes, David R.; Robb, Richard A.

    2013-01-01

    Mixed reality environments for medical applications have been explored and developed over the past three decades in an effort to enhance the clinician’s view of anatomy and facilitate the performance of minimally invasive procedures. These environments must faithfully represent the real surgical field and require seamless integration of pre- and intra-operative imaging, surgical instrument tracking, and display technology into a common framework centered around and registered to the patient. However, in spite of their reported benefits, few mixed reality environments have been successfully translated into clinical use. Several challenges that contribute to the difficulty in integrating such environments into clinical practice are presented here and discussed in terms of both technical and clinical limitations. This article should raise awareness among both developers and end-users toward facilitating a greater application of such environments in the surgical practice of the future. PMID:23632059

  2. On mixed reality environments for minimally invasive therapy guidance: systems architecture, successes and challenges in their implementation from laboratory to clinic.

    Science.gov (United States)

    Linte, Cristian A; Davenport, Katherine P; Cleary, Kevin; Peters, Craig; Vosburgh, Kirby G; Navab, Nassir; Edwards, Philip Eddie; Jannin, Pierre; Peters, Terry M; Holmes, David R; Robb, Richard A

    2013-03-01

    Mixed reality environments for medical applications have been explored and developed over the past three decades in an effort to enhance the clinician's view of anatomy and facilitate the performance of minimally invasive procedures. These environments must faithfully represent the real surgical field and require seamless integration of pre- and intra-operative imaging, surgical instrument tracking, and display technology into a common framework centered around and registered to the patient. However, in spite of their reported benefits, few mixed reality environments have been successfully translated into clinical use. Several challenges that contribute to the difficulty in integrating such environments into clinical practice are presented here and discussed in terms of both technical and clinical limitations. This article should raise awareness among both developers and end-users toward facilitating a greater application of such environments in the surgical practice of the future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Non-surgical treatment of hip osteoarthritis. Hip school, with or without the addition of manual therapy, in comparison to a minimal control intervention: Protocol for a three-armed randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Vach Werner

    2011-05-01

    Full Text Available Abstract Background Hip osteoarthritis is a common and chronic condition resulting in pain, functional disability and reduced quality of life. In the early stages of the disease, a combination of non-pharmacological and pharmacological treatment is recommended. There is evidence from several trials that exercise therapy is effective. In addition, single trials suggest that patient education in the form of a hip school is a promising intervention and that manual therapy is superior to exercise. Methods/Design This is a randomized clinical trial. Patients with clinical and radiological hip osteoarthritis, 40-80 years of age, and without indication for hip surgery were randomized into 3 groups. The active intervention groups A and B received six weeks of hip school, taught by a physiotherapist, for a total of 5 sessions. In addition, group B received manual therapy consisting of joint manipulation and soft-tissue therapy twice a week for six weeks. Group C received a self-care information leaflet containing advice on "live as usual" and stretching exercises from the hip school. The primary time point for assessing relative effectiveness is at the end of the six weeks intervention period with follow-ups after three and 12 months. Primary outcome measure is pain measured on an eleven-point numeric rating scale. Secondary outcome measures are the hip dysfunction and osteoarthritis outcome score, patient's global perceived effect, patient specific functional scale, general quality of life and hip range of motion. Discussion To our knowledge this is the first randomized clinical trial comparing a patient education program with or without the addition of manual therapy to a minimal intervention for patients with hip osteoarthritis. Trial registration ClinicalTrials NCT01039337

  4. The minimally tuned minimal supersymmetric standard model

    International Nuclear Information System (INIS)

    Essig, Rouven; Fortin, Jean-Francois

    2008-01-01

    The regions in the Minimal Supersymmetric Standard Model with the minimal amount of fine-tuning of electroweak symmetry breaking are presented for general messenger scale. No a priori relations among the soft supersymmetry breaking parameters are assumed and fine-tuning is minimized with respect to all the important parameters which affect electroweak symmetry breaking. The superpartner spectra in the minimally tuned region of parameter space are quite distinctive with large stop mixing at the low scale and negative squark soft masses at the high scale. The minimal amount of tuning increases enormously for a Higgs mass beyond roughly 120 GeV

  5. Optimizing the radiation therapy dose prescription for pediatric medulloblastoma: minimizing the life years lost attributable to failure to control the disease and late complication risk.

    Science.gov (United States)

    Brodin, N Patrik; Vogelius, Ivan R; Björk-Eriksson, Thomas; Munck Af Rosenschöld, Per; Maraldo, Maja V; Aznar, Marianne C; Specht, Lena; Bentzen, Søren M

    2014-04-01

    A mathematical framework is presented for simultaneously quantifying and evaluating the trade-off between tumor control and late complications for risk-based radiation therapy (RT) decision-support. To demonstrate this, we estimate life years lost (LYL) attributable to tumor recurrence, late cardiac toxicity and secondary cancers for standard-risk pediatric medulloblastoma (MB) patients and compare the effect of dose re-distribution on a common scale. Total LYL were derived, based on the LYL attributable to radiation-induced late complications and the LYL from not controlling the primary disease. We compared the estimated LYL for three different treatments in 10 patients: 1) standard 3D conformal RT; 2) proton therapy; 3) risk-adaptive photon treatment lowering the dose to part of the craniospinal (CS) target volume situated close to critical risk organs. Late toxicity is important, with 0.75 LYL (95% CI 0.60-7.2 years) for standard uniform 24 Gy CS irradiation. However, recurrence risk dominates the total LYL with 14.2 years (95% CI 13.4-16.6 years). Compared to standard treatment, a risk-adapted strategy prescribing 12 Gy to the spinal volume encompassing the 1st-10th thoracic vertebrae (Th1-Th10), and 36 Gy to the remaining CS volume, estimated a LYL reduction of 0.90 years (95% CI -0.18-2.41 years). Proton therapy with 36 Gy to the whole CS volume was associated with significantly fewer LYL compared to the risk-adapted photon strategies, with a mean LYL difference of 0.50 years (95% CI 0.25-2.60 years). Optimization of RT prescription strategies considering both late complications and the risk of recurrence, an all-cause mortality dose painting approach, was demonstrated. The risk-adapted techniques compared favorably to the standard, and although in this context, the gain is small compared to estimated uncertainty, this study demonstrates a framework for all-cause mortality risk estimation, rather than evaluates direct clinical applicability of risk

  6. Optimizing the radiation therapy dose prescription for pediatric medulloblastoma: Minimizing the life years lost attributable to failure to control the disease and late complication risk

    DEFF Research Database (Denmark)

    Brodin, N. Patrik; Vogelius, Ivan R.; Bjork-Eriksson, Thomas

    2014-01-01

    Background. A mathematical framework is presented for simultaneously quantifying and evaluating the trade-off between tumor control and late complications for risk-based radiation therapy (RT) decision-support. To demonstrate this, we estimate life years lost (LYL) attributable to tumor recurrence...... is important, with 0.75 LYL (95% CI 0.60-7.2 years) for standard uniform 24 Gy CS irradiation. However, recurrence risk dominates the total LYL with 14.2 years (95% CI 13.4-16.6 years). Compared to standard treatment, a risk-adapted strategy prescribing 12 Gy to the spinal volume encompassing the 1st-10th......, late cardiac toxicity and secondary cancers for standard-risk pediatric medulloblastoma (MB) patients and compare the effect of dose re-distribution on a common scale. Methods. Total LYL were derived, based on the LYL attributable to radiation-induced late complications and the LYL from not controlling...

  7. Serotonin augmentation therapy by escitalopram has minimal effects on amyloid-β levels in early-stage Alzheimer's-like disease in mice.

    Science.gov (United States)

    von Linstow, Christian Ulrich; Waider, Jonas; Grebing, Manuela; Metaxas, Athanasios; Lesch, Klaus Peter; Finsen, Bente

    2017-09-12

    Dysfunction of the serotonergic (5-HTergic) system has been implicated in the cognitive and behavioural symptoms of Alzheimer's disease (AD). Accumulation of toxic amyloid-β (Aβ) species is a hallmark of AD and an instigator of pathology. Serotonin (5-HT) augmentation therapy by treatment with selective serotonin reuptake inhibitors (SSRIs) in patients with AD has had mixed success in improving cognitive function, whereas SSRI administration to mice with AD-like disease has been shown to reduce Aβ pathology. The objective of this study was to investigate whether an increase in extracellular levels of 5-HT induced by chronic SSRI treatment reduces Aβ pathology and whether 5-HTergic deafferentation of the cerebral cortex could worsen Aβ pathology in the APP swe /PS1 ΔE9 (APP/PS1) mouse model of AD. We administered a therapeutic dose of the SSRI escitalopram (5 mg/kg/day) in the drinking water of 3-month-old APP/PS1 mice to increase levels of 5-HT, and we performed intracerebroventricular injections of the neurotoxin 5,7-dihydroxytryptamine (DHT) to remove 5-HTergic afferents. We validated the effectiveness of these interventions by serotonin transporter autoradiography (neocortex 79.7 ± 7.6%) and by high-performance liquid chromatography for 5-HT (neocortex 64% reduction). After 6 months of escitalopram treatment or housing after DHT-induced lesion, we evaluated brain tissue by mesoscale multiplex analysis and sections by IHC analysis. Amyloid-β-containing plaques had formed in the neocortex and hippocampus of 9-month-old APP/PS1 mice after 6 months of escitalopram treatment and 5-HTergic deafferentation. Unexpectedly, levels of insoluble Aβ42 were unaffected in the neocortex and hippocampus after both types of interventions. Levels of insoluble Aβ40 increased in the neocortex of SSRI-treated mice compared with those treated with vehicle control, but they were unaffected in the hippocampus. 5-HTergic deafferentation was without effect on the levels of

  8. Evaluation of localization errors for craniospinal axis irradiation delivery using volume modulated arc therapy and proposal of a technique to minimize such errors

    International Nuclear Information System (INIS)

    Myers, Pamela; Stathakis, Sotirios; Mavroidis, Panayiotis; Esquivel, Carlos; Papanikolaou, Niko

    2013-01-01

    Purpose: To dosimetrically evaluate the effects of improper patient positioning in the junction area of a VMAT cranio-spinal axis irradiation technique consisting of one superior and one inferior arc and propose a solution to minimize these patient setup errors. Methods: Five (n = 5) cranio-spinal axis irradiation patients were planned with 2 arcs: one superior and one inferior. In order to mimic patient setup errors, the plans were recalculated with the inferior isocenter shifted by: 1, 2, 5, and 10 mm superiorly, and 1, 2, 5, and 10 mm inferiorly. The plans were then compared with the corresponding original, non-shifted arc plans on the grounds of target metrics such as conformity number and homogeneity index, as well as several normal tissue dose descriptors. “Gradient-optimized” plans were then created for each patient in an effort to reduce dose discrepancies due to setup errors. Results: Percent differences were calculated in order to compare each of the eight shifted plans with the original non-shifted arc plan, which corresponds to the ideal patient setup. The conformity number was on average lower by 0.9%, 2.7%, 5.8%, and 9.1% for the 1, 2, 5, and 10 mm inferiorly-shifted plans and 0.4%, 0.8%, 2.8%, and 6.0% for the respective superiorly-shifted plans. The homogeneity indices were, averaged among the five patients and they indicated less homogeneous dose distributions by 0.03%, 0.3%, 1.0%, and 2.8% for the inferior shifts and 0.2%, 1.2%, 6.3%, and 15.3% for the superior shifts. Overall, the mean doses to the organs at risk deviate by less than 2% for the 1, 2, and 5 mm shifted plans. The 10 mm shifted plans, however, showed average percent differences, over all studied organs, from the original plan of up to 5.6%. Using “gradient-optimized” plans, the average dose differences were reduced by 0.2%, 0.5%, 1.2%, and 2.1% for 1, 2, 5, and 10 mm shifts, respectively compared to the originally optimized plans, and the maximum dose differences were

  9. Early recovery of circulating immature B cells in B-lymphoblastic leukemia patients after CD19 targeted CAR T cell therapy: A pitfall for minimal residual disease detection.

    Science.gov (United States)

    Xiao, Wenbin; Salem, Dalia; McCoy, Catharine S; Lee, Daniel; Shah, Nirali N; Stetler-Stevenson, Maryalice; Yuan, Constance M

    2017-09-09

    CD19-targeted chimeric-antigen receptor-modified T-cells (CAR-T) are promising in the treatment of refractory B-lymphoblastic leukemia (B-ALL). Minimal residual disease (MRD) detection by multicolor flow cytometry (FCM) is critical to distinguish B-ALL MRD from regenerating, non-neoplastic B-cell populations. FCM was performed on samples from 9 patients with B-ALL treated with CAR-T. All 9 patients showed response to CAR-T. Additionally, FCM revealed circulating CD10 + B cells, potentially mimicking MRD. Circulating CD10+ B-cells were detected in blood from 3 days to 3 months after CAR-T, comprising 73% (median) of B-cells (52-83%, 95%CI). They expressed CD19, CD10, CD20, bright CD9, CD22, CD24, moderate CD38 and dim CD58, but were CD34 (-), with bright CD45 and polyclonal surface light chain immunoglobulin (sIg) expression. A similar CD10 + B-cell subpopulation was detected by marrow FCM, amidst abundant B-cell precursors. These circulating CD10 + B-cells are compatible with immature B-cells, and are a reflection of B-cell recovery within the marrow. They are immunophenotypically distinguishable from residual B-ALL. Expression of light chain sIg and key surface antigens characterizing regenerating B-cell precursors can distinguish immature B-cells from B-ALL MRD and prevent misdiagnosis. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.

  10. Sequential Targeting of CD52 and TNF Allows Early Minimization Therapy in Kidney Transplantation: From a Biomarker to Targeting in a Proof-Of-Concept Trial.

    Directory of Open Access Journals (Sweden)

    Ondrej Viklicky

    Full Text Available There is high medical need for safe long-term immunosuppression monotherapy in kidney transplantation. Selective targeting of post-transplant alloantigen-(reactivated effector-T cells by anti-TNF antibodies after global T cell depletion may allow safe drug minimization, however, it is unsolved what might be the best maintenance monotherapy.In this open, prospective observational single-centre trial, 20 primary deceased donor kidney transplant recipients received 2x20 mg Alemtuzumab (d0/d1 followed by 5 mg/kg Infliximab (d2. For 14 days all patients received only tacrolimus, then they were allocated to either receive tacrolimus (TAC, n = 13 or sirolimus (SIR, n = 7 monotherapy, respectively. Protocol biopsies and extensive immune monitoring were performed and patients were followed-up for 60 months.TAC-monotherapy resulted in excellent graft survival (5yr 92%, 95%CI: 56.6-98.9 and function, normal histology, and no proteinuria. Immune monitoring revealed low intragraft inflammation (urinary IP-10 and hints for the development of operational tolerance signature in the TAC- but not SIR-group. Remarkably, the TAC-monotherapy was successful in all five presensitized (ELISPOT+ patients. However, recruitment into SIR-arm was stopped (after n = 7 because of high incidence of proteinuria and acute/chronic rejection in biopsies. No opportunistic infections occurred during follow-up.In conclusion, our novel fast-track TAC-monotherapy protocol is likely to be safe and preliminary results indicated an excellent 5-year outcome, however, a full-scale study will be needed to confirm our findings.EudraCT Number: 2006-003110-18.

  11. Prioritized Contact Transport Stream

    Science.gov (United States)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  12. Minimally Invasive Surgery in Thymic Malignances

    Directory of Open Access Journals (Sweden)

    Wentao FANG

    2018-04-01

    Full Text Available Surgery is the most important therapy for thymic malignances. The last decade has seen increasing adoption of minimally invasive surgery (MIS for thymectomy. MIS for early stage thymoma patients has been shown to yield similar oncological results while being helpful in minimize surgical trauma, improving postoperative recovery, and reduce incisional pain. Meanwhile, With the advance in surgical techniques, the patients with locally advanced thymic tumors, preoperative induction therapies or recurrent diseases, may also benefit from MIS in selected cases.

  13. The minimal non-minimal standard model

    International Nuclear Information System (INIS)

    Bij, J.J. van der

    2006-01-01

    In this Letter I discuss a class of extensions of the standard model that have a minimal number of possible parameters, but can in principle explain dark matter and inflation. It is pointed out that the so-called new minimal standard model contains a large number of parameters that can be put to zero, without affecting the renormalizability of the model. With the extra restrictions one might call it the minimal (new) non-minimal standard model (MNMSM). A few hidden discrete variables are present. It is argued that the inflaton should be higher-dimensional. Experimental consequences for the LHC and the ILC are discussed

  14. American Music Therapy Association

    Science.gov (United States)

    American Music Therapy Association Home Contact News Help/FAQ Members Only Login Quick Links Facts About Music Therapy Qualifications ... with AMTA Sponsor AMTA Events Social Networking Support Music Therapy When you shop at AmazonSmile, Amazon will ...

  15. Irritant Contact Dermatitis : Diagnosis and Risk Factors

    NARCIS (Netherlands)

    Schuttelaar, Maria; Johansen, Jeanne Duus; Lepoittevin, Jean-Pierre; Thyssen, Jacob P.

    2016-01-01

    Irritant contact dermatitis is frequent and is induced by direct and repeated contact with skin irritants such as detergents, abrasives, solvents and physical factors such as dry air and occlusion (by wearing gloves) but also water. When dermatitis has developed, even a minimal skin irritation, like

  16. Impact of therapist change after initial contact and traumatic burden on dropout in a naturalistic sample of inpatients with borderline pathology receiving dialectical behavior therapy.

    Science.gov (United States)

    Steuwe, Carolin; Berg, Michaela; Driessen, Martin; Beblo, Thomas

    2017-01-01

    This study focused on the predictors of therapy dropout in a naturalistic sample of patients with borderline pathology receiving dialectical behavior therapy (DBT) in an inpatient setting. We assumed that the change of the therapist between DBT-briefing and start of DBT-treatment as well as comorbid posttraumatic stress disorder (PTSD) and childhood trauma history were associated with elevated dropout. Eighty-nine participants with borderline pathology (≥ 3 borderline personality disorder criteria) receiving an inpatient DBT program completed a quality assurance questionnaire set assessing demographic information and pretreatment psychopathology during the days of their inpatient stay. Beyond that, changes of therapists were documented. The predictor analyses were investigated with generalized estimating equations. The dropout rate was 24.7%. A change of therapist between DBT-briefing and treatment as well as high childhood emotional abuse was associated with premature termination of treatment. Higher values of physical neglect during childhood were associated with a protective effect on treatment dropout. Surprisingly, this was also true for comorbid PTSD. This study supports the importance of therapy process variables as predictors of therapy dropout in borderline pathology. A change of therapist between DBT-briefing and treatment was associated with an increased vulnerability for dropping out of treatment and should therefore be avoided if possible. Against our hypotheses, a comorbid PTSD was even protective with regard to DBT dropout. Therefore, this severely suffering patient group should not be rejected from treatment assuming them to be too unstable for psychotherapy. However, results need to be replicated. ClinicalTrials.gov Identifier: NCT03018639, retrospectively registered on January 9, 2017.

  17. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  18. Center for Innovative Minimally Invasive Therapy (CIMIT)

    Science.gov (United States)

    2004-10-01

    data. We hypothesize that a) the portable gait evaluator will provide ankle dorsi/ plantar flexion and external/internal foot rotation motion output...output from 2 sensors (pitch gyro and a bend sensor) is used to determining ankle dorsi flexion/ plantar flexion is underway. The gyroscopic data for... Fascia 34 14.9 ± 2.2 137.5 ± 14.2 Muscle 40 20.9 ± 2.5 163.7 ± 19.9 Bone 34 32.5 ± 4.2 101.3 ± 16.8 Cartilage 34 23.3 ± 3.3 127.3 ± 15.2 Dura 34 41.7

  19. Regularity of Minimal Surfaces

    CERN Document Server

    Dierkes, Ulrich; Tromba, Anthony J; Kuster, Albrecht

    2010-01-01

    "Regularity of Minimal Surfaces" begins with a survey of minimal surfaces with free boundaries. Following this, the basic results concerning the boundary behaviour of minimal surfaces and H-surfaces with fixed or free boundaries are studied. In particular, the asymptotic expansions at interior and boundary branch points are derived, leading to general Gauss-Bonnet formulas. Furthermore, gradient estimates and asymptotic expansions for minimal surfaces with only piecewise smooth boundaries are obtained. One of the main features of free boundary value problems for minimal surfaces is t

  20. Preparation and characterization of a hydrogel carrier to deliver gatifloxacin and its application as a therapeutic contact lens for bacterial keratitis therapy

    International Nuclear Information System (INIS)

    Shi, Yunfeng; Fu, Yeyun; Ma, Dong; Xue, Wei; Lv, Hongling; Lu, Qingjun; Zhong, Jingxiang; Huang, Yuexin

    2013-01-01

    A soft and biocompatible hydrogel exhibiting a higher loading and the sustained release of gatifloxacin (GFLX) was developed as the potential matrix to fabricate a therapeutic contact lens for curing bacterial keratitis. 2-hydroxyethyl methacrylate (HEMA) and five other kinds of vinyl monomers with different side groups were used as co-monomers. Copolymerization took place in a cornea shaped mould via the gradient temperature-elevating method. The results of drug loading and in vitro release experiments showed that P(HEMA-co-MAA) achieved the highest drug loading of 11.78±0.77 µg mg −1 among the obtained hydrogels, as well as a slow release. In addition, its physical properties and cytocompatibility were also proved suitable and safe for wearing on the eye surface. In animal experiments, a rat model of bacterial keratitis was established and employed to evaluate the clinical results of certain treatments employing obtained hydrogels; saline and GFLX eye drops were used as negative and positive controls, respectively. Corneal abscess and opacity caused by epithelial erosion and stromal ulceration were almost healed after wearing the drug loaded P(HEMA-co-MAA) hydrogel for 48 h. Its excellent antibacterial effect was also confirmed by testing the bacterial activity in tear extraction via the streak line method. (paper)

  1. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  2. Minimally invasive orthognathic surgery.

    Science.gov (United States)

    Resnick, Cory M; Kaban, Leonard B; Troulis, Maria J

    2009-02-01

    Minimally invasive surgery is defined as the discipline in which operative procedures are performed in novel ways to diminish the sequelae of standard surgical dissections. The goals of minimally invasive surgery are to reduce tissue trauma and to minimize bleeding, edema, and injury, thereby improving the rate and quality of healing. In orthognathic surgery, there are two minimally invasive techniques that can be used separately or in combination: (1) endoscopic exposure and (2) distraction osteogenesis. This article describes the historical developments of the fields of orthognathic surgery and minimally invasive surgery, as well as the integration of the two disciplines. Indications, techniques, and the most current outcome data for specific minimally invasive orthognathic surgical procedures are presented.

  3. Correlates of minimal dating.

    Science.gov (United States)

    Leck, Kira

    2006-10-01

    Researchers have associated minimal dating with numerous factors. The present author tested shyness, introversion, physical attractiveness, performance evaluation, anxiety, social skill, social self-esteem, and loneliness to determine the nature of their relationships with 2 measures of self-reported minimal dating in a sample of 175 college students. For women, shyness, introversion, physical attractiveness, self-rated anxiety, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. For men, physical attractiveness, observer-rated social skill, social self-esteem, and loneliness correlated with 1 or both measures of minimal dating. The patterns of relationships were not identical for the 2 indicators of minimal dating, indicating the possibility that minimal dating is not a single construct as researchers previously believed. The present author discussed implications and suggestions for future researchers.

  4. Hexavalent Chromium Minimization Strategy

    Science.gov (United States)

    2011-05-01

    Logistics 4 Initiative - DoD Hexavalent Chromium Minimization Non- Chrome Primer IIEXAVAJ ENT CHRO:M I~UMI CHROMIUM (VII Oil CrfVli.J CANCEfl HAnRD CD...Management Office of the Secretary of Defense Hexavalent Chromium Minimization Strategy Report Documentation Page Form ApprovedOMB No. 0704-0188...00-2011 4. TITLE AND SUBTITLE Hexavalent Chromium Minimization Strategy 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  5. Minimal Super Technicolor

    DEFF Research Database (Denmark)

    Antola, M.; Di Chiara, S.; Sannino, F.

    2011-01-01

    We introduce novel extensions of the Standard Model featuring a supersymmetric technicolor sector (supertechnicolor). As the first minimal conformal supertechnicolor model we consider N=4 Super Yang-Mills which breaks to N=1 via the electroweak interactions. This is a well defined, economical......, between unparticle physics and Minimal Walking Technicolor. We consider also other N =1 extensions of the Minimal Walking Technicolor model. The new models allow all the standard model matter fields to acquire a mass....

  6. Minimizing corrosive action in timber bridges treated with waterborne preservatives

    Science.gov (United States)

    Samuel L. Zelinka; Douglas R. Rammer; James P. Wacker

    2007-01-01

    This work will briefly review published literature and current research activities on the corrosion of metals in contact with wood treated with waterborne alternatives to CCA. In addition, recommendations to minimize these corrosive effects in timber bridges will be discussed.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  9. Minimizing Mutual Couping

    DEFF Research Database (Denmark)

    2010-01-01

    Disclosed herein are techniques, systems, and methods relating to minimizing mutual coupling between a first antenna and a second antenna.......Disclosed herein are techniques, systems, and methods relating to minimizing mutual coupling between a first antenna and a second antenna....

  10. Ruled Laguerre minimal surfaces

    KAUST Repository

    Skopenkov, Mikhail; Pottmann, Helmut; Grohs, Philipp

    2011-01-01

    A Laguerre minimal surface is an immersed surface in ℝ 3 being an extremal of the functional ∫ (H 2/K-1)dA. In the present paper, we prove that the only ruled Laguerre minimal surfaces are up to isometry the surfaces ℝ (φλ) = (Aφ, Bφ, Cφ + D cos 2φ

  11. Antibacterial surface design - Contact kill

    Science.gov (United States)

    Kaur, Rajbir; Liu, Song

    2016-08-01

    Designing antibacterial surfaces has become extremely important to minimize Healthcare Associated Infections which are a major cause of mortality worldwide. A previous biocide-releasing approach is based on leaching of encapsulated biocides such as silver and triclosan which exerts negative impacts on the environment and potentially contributes to the development of bacterial resistance. This drawback of leachable compounds led to the shift of interest towards a more sustainable and environmentally friendly approach: contact-killing surfaces. Biocides that can be bound onto surfaces to give the substrates contact-active antibacterial activity include quaternary ammonium compounds (QACs), quaternary phosphoniums (QPs), carbon nanotubes, antibacterial peptides, and N-chloramines. Among the above, QACs and N-chloramines are the most researched contact-active biocides. We review the engineering of contact-active surfaces using QACs or N-chloramines, the modes of actions as well as the test methods. The charge-density threshold of cationic surfaces for desired antibacterial efficacy and attempts to combine various biocides for the generation of new contact-active surfaces are discussed in detail. Surface positive charge density is identified as a key parameter to define antibacterial efficacy. We expect that this research field will continue to attract more research interest in view of the potential impact of self-disinfective surfaces on healthcare-associated infections, food safety and corrosion/fouling resistance required on industrial surfaces such as oil pipes and ship hulls.

  12. The effects of acceptance and commitment therapy on eating behavior and diet delivered through face-to-face contact and a mobile app: a randomized controlled trial.

    Science.gov (United States)

    Järvelä-Reijonen, Elina; Karhunen, Leila; Sairanen, Essi; Muotka, Joona; Lindroos, Sanni; Laitinen, Jaana; Puttonen, Sampsa; Peuhkuri, Katri; Hallikainen, Maarit; Pihlajamäki, Jussi; Korpela, Riitta; Ermes, Miikka; Lappalainen, Raimo; Kolehmainen, Marjukka

    2018-02-27

    Internal motivation and good psychological capabilities are important factors in successful eating-related behavior change. Thus, we investigated whether general acceptance and commitment therapy (ACT) affects reported eating behavior and diet quality and whether baseline perceived stress moderates the intervention effects. Secondary analysis of unblinded randomized controlled trial in three Finnish cities. Working-aged adults with psychological distress and overweight or obesity in three parallel groups: (1) ACT-based Face-to-face (n = 70; six group sessions led by a psychologist), (2) ACT-based Mobile (n = 78; one group session and mobile app), and (3) Control (n = 71; only the measurements). At baseline, the participants' (n = 219, 85% females) mean body mass index was 31.3 kg/m 2 (SD = 2.9), and mean age was 49.5 years (SD = 7.4). The measurements conducted before the 8-week intervention period (baseline), 10 weeks after the baseline (post-intervention), and 36 weeks after the baseline (follow-up) included clinical measurements, questionnaires of eating behavior (IES-1, TFEQ-R18, HTAS, ecSI 2.0, REBS), diet quality (IDQ), alcohol consumption (AUDIT-C), perceived stress (PSS), and 48-h dietary recall. Hierarchical linear modeling (Wald test) was used to analyze the differences in changes between groups. Group x time interactions showed that the subcomponent of intuitive eating (IES-1), i.e., Eating for physical rather than emotional reasons, increased in both ACT-based groups (p = .019); the subcomponent of TFEQ-R18, i.e., Uncontrolled eating, decreased in the Face-to-face group (p = .020); the subcomponent of health and taste attitudes (HTAS), i.e., Using food as a reward, decreased in the Mobile group (p = .048); and both subcomponent of eating competence (ecSI 2.0), i.e., Food acceptance (p = .048), and two subcomponents of regulation of eating behavior (REBS), i.e., Integrated and Identified regulation (p

  13. Minimizing Exposure at Work

    Science.gov (United States)

    ; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Home Page Pesticide Health and Safety Information Safe Use Practices Minimizing Exposure at Work Pesticides - Pennsylvania State University Cooperative Extension Personal Protective Equipment for Working

  14. Minimalism. Clip and Save.

    Science.gov (United States)

    Hubbard, Guy

    2002-01-01

    Provides background information on the art movement called "Minimalism" discussing why it started and its characteristics. Includes learning activities and information on the artist, Donald Judd. Includes a reproduction of one of his art works and discusses its content. (CMK)

  15. Ruled Laguerre minimal surfaces

    KAUST Repository

    Skopenkov, Mikhail

    2011-10-30

    A Laguerre minimal surface is an immersed surface in ℝ 3 being an extremal of the functional ∫ (H 2/K-1)dA. In the present paper, we prove that the only ruled Laguerre minimal surfaces are up to isometry the surfaces ℝ (φλ) = (Aφ, Bφ, Cφ + D cos 2φ) + λ(sin φ, cos φ, 0), where A,B,C,D ε ℝ are fixed. To achieve invariance under Laguerre transformations, we also derive all Laguerre minimal surfaces that are enveloped by a family of cones. The methodology is based on the isotropic model of Laguerre geometry. In this model a Laguerre minimal surface enveloped by a family of cones corresponds to a graph of a biharmonic function carrying a family of isotropic circles. We classify such functions by showing that the top view of the family of circles is a pencil. © 2011 Springer-Verlag.

  16. Contact Dermatitis in Pediatrics.

    Science.gov (United States)

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  17. Minimal and careful processing

    OpenAIRE

    Nielsen, Thorkild

    2004-01-01

    In several standards, guidelines and publications, organic food processing is strongly associated with "minimal processing" and "careful processing". The term "minimal processing" is nowadays often used in the general food processing industry and described in literature. The term "careful processing" is used more specifically within organic food processing but is not yet clearly defined. The concept of carefulness seems to fit very well with the processing of organic foods, especially if it i...

  18. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  19. Waste minimization assessment procedure

    International Nuclear Information System (INIS)

    Kellythorne, L.L.

    1993-01-01

    Perry Nuclear Power Plant began developing a waste minimization plan early in 1991. In March of 1991 the plan was documented following a similar format to that described in the EPA Waste Minimization Opportunity Assessment Manual. Initial implementation involved obtaining management's commitment to support a waste minimization effort. The primary assessment goal was to identify all hazardous waste streams and to evaluate those streams for minimization opportunities. As implementation of the plan proceeded, non-hazardous waste streams routinely generated in large volumes were also evaluated for minimization opportunities. The next step included collection of process and facility data which would be useful in helping the facility accomplish its assessment goals. This paper describes the resources that were used and which were most valuable in identifying both the hazardous and non-hazardous waste streams that existed on site. For each material identified as a waste stream, additional information regarding the materials use, manufacturer, EPA hazardous waste number and DOT hazard class was also gathered. Once waste streams were evaluated for potential source reduction, recycling, re-use, re-sale, or burning for heat recovery, with disposal as the last viable alternative

  20. Minimal quantization and confinement

    International Nuclear Information System (INIS)

    Ilieva, N.P.; Kalinowskij, Yu.L.; Nguyen Suan Han; Pervushin, V.N.

    1987-01-01

    A ''minimal'' version of the Hamiltonian quantization based on the explicit solution of the Gauss equation and on the gauge-invariance principle is considered. By the example of the one-particle Green function we show that the requirement for gauge invariance leads to relativistic covariance of the theory and to more proper definition of the Faddeev - Popov integral that does not depend on the gauge choice. The ''minimal'' quantization is applied to consider the gauge-ambiguity problem and a new topological mechanism of confinement

  1. Minimal Composite Inflation

    DEFF Research Database (Denmark)

    Channuie, Phongpichit; Jark Joergensen, Jakob; Sannino, Francesco

    2011-01-01

    We investigate models in which the inflaton emerges as a composite field of a four dimensional, strongly interacting and nonsupersymmetric gauge theory featuring purely fermionic matter. We show that it is possible to obtain successful inflation via non-minimal coupling to gravity, and that the u......We investigate models in which the inflaton emerges as a composite field of a four dimensional, strongly interacting and nonsupersymmetric gauge theory featuring purely fermionic matter. We show that it is possible to obtain successful inflation via non-minimal coupling to gravity...

  2. Minimalism and Speakers’ Intuitions

    Directory of Open Access Journals (Sweden)

    Matías Gariazzo

    2011-08-01

    Full Text Available Minimalism proposes a semantics that does not account for speakers’ intuitions about the truth conditions of a range of sentences or utterances. Thus, a challenge for this view is to offer an explanation of how its assignment of semantic contents to these sentences is grounded in their use. Such an account was mainly offered by Soames, but also suggested by Cappelen and Lepore. The article criticizes this explanation by presenting four kinds of counterexamples to it, and arrives at the conclusion that minimalism has not successfully answered the above-mentioned challenge.

  3. Minimal open strings

    International Nuclear Information System (INIS)

    Hosomichi, Kazuo

    2008-01-01

    We study FZZT-branes and open string amplitudes in (p, q) minimal string theory. We focus on the simplest boundary changing operators in two-matrix models, and identify the corresponding operators in worldsheet theory through the comparison of amplitudes. Along the way, we find a novel linear relation among FZZT boundary states in minimal string theory. We also show that the boundary ground ring is realized on physical open string operators in a very simple manner, and discuss its use for perturbative computation of higher open string amplitudes.

  4. A survey on classical minimal surface theory

    CERN Document Server

    Meeks, William H

    2012-01-01

    Meeks and Pérez present a survey of recent spectacular successes in classical minimal surface theory. The classification of minimal planar domains in three-dimensional Euclidean space provides the focus of the account. The proof of the classification depends on the work of many currently active leading mathematicians, thus making contact with much of the most important results in the field. Through the telling of the story of the classification of minimal planar domains, the general mathematician may catch a glimpse of the intrinsic beauty of this theory and the authors' perspective of what is happening at this historical moment in a very classical subject. This book includes an updated tour through some of the recent advances in the theory, such as Colding-Minicozzi theory, minimal laminations, the ordering theorem for the space of ends, conformal structure of minimal surfaces, minimal annular ends with infinite total curvature, the embedded Calabi-Yau problem, local pictures on the scale of curvature and t...

  5. Thin film photovoltaic devices with a minimally conductive buffer layer

    Science.gov (United States)

    Barnes, Teresa M.; Burst, James

    2016-11-15

    A thin film photovoltaic device (100) with a tunable, minimally conductive buffer (128) layer is provided. The photovoltaic device (100) may include a back contact (150), a transparent front contact stack (120), and an absorber (140) positioned between the front contact stack (120) and the back contact (150). The front contact stack (120) may include a low resistivity transparent conductive oxide (TCO) layer (124) and a buffer layer (128) that is proximate to the absorber layer (140). The photovoltaic device (100) may also include a window layer (130) between the buffer layer (128) and the absorber (140). In some cases, the buffer layer (128) is minimally conductive, with its resistivity being tunable, and the buffer layer (128) may be formed as an alloy from a host oxide and a high-permittivity oxide. The high-permittivity oxide may further be chosen to have a bandgap greater than the host oxide.

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  11. Colored Contact Lens Dangers

    Science.gov (United States)

    ... Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados ... truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non- ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager ... the lenses. Never share contact lenses with another person. Get follow up exams with your eye care ...

  13. Contact Angle Goniometer

    Data.gov (United States)

    Federal Laboratory Consortium — Description:The FTA32 goniometer provides video-based contact angle and surface tension measurement. Contact angles are measured by fitting a mathematical expression...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... glow-in-the-dark lizard lenses, costume contacts can certainly add a spooky, eye-popping touch. But ... consideration as a standard contact lens because they can be purchased over-the-counter or on the ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  18. Dermatitis, contact (image)

    Science.gov (United States)

    This picture shows a skin inflammation (dermatitis) caused by contact with a material that causes an allergic reaction in this person. Contact dermatitis is a relatively common condition, and can be caused ...

  19. Contact materials for nanoelectronics

    KAUST Repository

    Alshareef, Husam N.; Quevedo-Ló pez, Manuel Angel Quevedo; Majhi, Prashant

    2011-01-01

    In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  2. Minimal model holography

    International Nuclear Information System (INIS)

    Gaberdiel, Matthias R; Gopakumar, Rajesh

    2013-01-01

    We review the duality relating 2D W N minimal model conformal field theories, in a large-N ’t Hooft like limit, to higher spin gravitational theories on AdS 3 . This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Higher spin theories and holography’. (review)

  3. Minimal constrained supergravity

    Energy Technology Data Exchange (ETDEWEB)

    Cribiori, N. [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Dall' Agata, G., E-mail: dallagat@pd.infn.it [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Farakos, F. [Dipartimento di Fisica e Astronomia “Galileo Galilei”, Università di Padova, Via Marzolo 8, 35131 Padova (Italy); INFN, Sezione di Padova, Via Marzolo 8, 35131 Padova (Italy); Porrati, M. [Center for Cosmology and Particle Physics, Department of Physics, New York University, 4 Washington Place, New York, NY 10003 (United States)

    2017-01-10

    We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  4. Hazardous waste minimization

    International Nuclear Information System (INIS)

    Freeman, H.

    1990-01-01

    This book presents an overview of waste minimization. Covers applications of technology to waste reduction, techniques for implementing programs, incorporation of programs into R and D, strategies for private industry and the public sector, and case studies of programs already in effect

  5. Minimally invasive distal pancreatectomy

    NARCIS (Netherlands)

    Røsok, Bård I.; de Rooij, Thijs; van Hilst, Jony; Diener, Markus K.; Allen, Peter J.; Vollmer, Charles M.; Kooby, David A.; Shrikhande, Shailesh V.; Asbun, Horacio J.; Barkun, Jeffrey; Besselink, Marc G.; Boggi, Ugo; Conlon, Kevin; Han, Ho Seong; Hansen, Paul; Kendrick, Michael L.; Kooby, David; Montagnini, Andre L.; Palanivelu, Chinnasamy; Wakabayashi, Go; Zeh, Herbert J.

    2017-01-01

    The first International conference on Minimally Invasive Pancreas Resection was arranged in conjunction with the annual meeting of the International Hepato-Pancreato-Biliary Association (IHPBA), in Sao Paulo, Brazil on April 19th 2016. The presented evidence and outcomes resulting from the session

  6. Minimal DBM Substraction

    DEFF Research Database (Denmark)

    David, Alexandre; Håkansson, John; G. Larsen, Kim

    In this paper we present an algorithm to compute DBM substractions with a guaranteed minimal number of splits and disjoint DBMs to avoid any redundance. The substraction is one of the few operations that result in a non-convex zone, and thus, requires splitting. It is of prime importance to reduce...

  7. Minimal constrained supergravity

    Directory of Open Access Journals (Sweden)

    N. Cribiori

    2017-01-01

    Full Text Available We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  8. Minimal constrained supergravity

    International Nuclear Information System (INIS)

    Cribiori, N.; Dall'Agata, G.; Farakos, F.; Porrati, M.

    2017-01-01

    We describe minimal supergravity models where supersymmetry is non-linearly realized via constrained superfields. We show that the resulting actions differ from the so called “de Sitter” supergravities because we consider constraints eliminating directly the auxiliary fields of the gravity multiplet.

  9. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  10. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  11. Hydrogenation of passivated contacts

    Energy Technology Data Exchange (ETDEWEB)

    Nemeth, William; Yuan, Hao-Chih; LaSalvia, Vincenzo; Stradins, Pauls; Page, Matthew R.

    2018-03-06

    Methods of hydrogenation of passivated contacts using materials having hydrogen impurities are provided. An example method includes applying, to a passivated contact, a layer of a material, the material containing hydrogen impurities. The method further includes subsequently annealing the material and subsequently removing the material from the passivated contact.

  12. Mixed Lubricated Line Contacts

    NARCIS (Netherlands)

    Faraon, I.C.

    2005-01-01

    The present work deals with friction in mixed lubricated line contacts. Components in systems are becoming smaller and due to, for instance power transmitted, partial contact may occur. In industrial applications, friction between the moving contacting surfaces cannot be avoided, therefore it is

  13. New Cosmetic Contact Allergens

    Directory of Open Access Journals (Sweden)

    An Goossens

    2015-02-01

    Full Text Available Allergic and photo-allergic contact dermatitis, and immunologic contact urticaria are potential immune-mediated adverse effects from cosmetics. Fragrance components and preservatives are certainly the most frequently observed allergens; however, all ingredients must be considered when investigating for contact allergy.

  14. Minimal abdominal incisions

    Directory of Open Access Journals (Sweden)

    João Carlos Magi

    2017-04-01

    Full Text Available Minimally invasive procedures aim to resolve the disease with minimal trauma to the body, resulting in a rapid return to activities and in reductions of infection, complications, costs and pain. Minimally incised laparotomy, sometimes referred to as minilaparotomy, is an example of such minimally invasive procedures. The aim of this study is to demonstrate the feasibility and utility of laparotomy with minimal incision based on the literature and exemplifying with a case. The case in question describes reconstruction of the intestinal transit with the use of this incision. Male, young, HIV-positive patient in a late postoperative of ileotiflectomy, terminal ileostomy and closing of the ascending colon by an acute perforating abdomen, due to ileocolonic tuberculosis. The barium enema showed a proximal stump of the right colon near the ileostomy. The access to the cavity was made through the orifice resulting from the release of the stoma, with a lateral-lateral ileo-colonic anastomosis with a 25 mm circular stapler and manual closure of the ileal stump. These surgeries require their own tactics, such as rigor in the lysis of adhesions, tissue traction, and hemostasis, in addition to requiring surgeon dexterity – but without the need for investments in technology; moreover, the learning curve is reported as being lower than that for videolaparoscopy. Laparotomy with minimal incision should be considered as a valid and viable option in the treatment of surgical conditions. Resumo: Procedimentos minimamente invasivos visam resolver a doença com o mínimo de trauma ao organismo, resultando em retorno rápido às atividades, reduções nas infecções, complicações, custos e na dor. A laparotomia com incisão mínima, algumas vezes referida como minilaparotomia, é um exemplo desses procedimentos minimamente invasivos. O objetivo deste trabalho é demonstrar a viabilidade e utilidade das laparotomias com incisão mínima com base na literatura e

  15. Minimal Walking Technicolor

    DEFF Research Database (Denmark)

    Foadi, Roshan; Frandsen, Mads Toudal; A. Ryttov, T.

    2007-01-01

    Different theoretical and phenomenological aspects of the Minimal and Nonminimal Walking Technicolor theories have recently been studied. The goal here is to make the models ready for collider phenomenology. We do this by constructing the low energy effective theory containing scalars......, pseudoscalars, vector mesons and other fields predicted by the minimal walking theory. We construct their self-interactions and interactions with standard model fields. Using the Weinberg sum rules, opportunely modified to take into account the walking behavior of the underlying gauge theory, we find...... interesting relations for the spin-one spectrum. We derive the electroweak parameters using the newly constructed effective theory and compare the results with the underlying gauge theory. Our analysis is sufficiently general such that the resulting model can be used to represent a generic walking technicolor...

  16. CONTACT RESISTANCE MODELING

    Directory of Open Access Journals (Sweden)

    S. V. LOSKUTOV

    2018-05-01

    Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.

  17. Legal incentives for minimizing waste

    International Nuclear Information System (INIS)

    Clearwater, S.W.; Scanlon, J.M.

    1991-01-01

    Waste minimization, or pollution prevention, has become an integral component of federal and state environmental regulation. Minimizing waste offers many economic and public relations benefits. In addition, waste minimization efforts can also dramatically reduce potential criminal requirements. This paper addresses the legal incentives for minimizing waste under current and proposed environmental laws and regulations

  18. Contact and symplectic topology

    CERN Document Server

    Colin, Vincent; Stipsicz, András

    2014-01-01

    Symplectic and contact geometry naturally emerged from the mathematical description of classical physics. The discovery of new rigidity phenomena and properties satisfied by these geometric structures launched a new research field worldwide. The intense activity of many European research groups in this field is reflected by the ESF Research Networking Programme "Contact And Symplectic Topology" (CAST). The lectures of the Summer School in Nantes (June 2011) and of the CAST Summer School in Budapest (July 2012) provide a nice panorama of many aspects of the present status of contact and symplectic topology. The notes of the minicourses offer a gentle introduction to topics which have developed in an amazing speed in the recent past. These topics include 3-dimensional and higher dimensional contact topology, Fukaya categories, asymptotically holomorphic methods in contact topology, bordered Floer homology, embedded contact homology, and flexibility results for Stein manifolds.

  19. Minimally invasive surgery for esophageal achalasia

    OpenAIRE

    Bonavina, Luigi

    2006-01-01

    Esophageal achalasia is the most commonly diagnosed primary esophageal motor disorder and the second most common functional esophageal disorder. Current therapy of achalasia is directed toward elimination of the outflow resistance caused by failure of the lower esophageal sphincter to relax completely upon swallowing. The advent of minimally invasive surgery has nearly replaced endoscopic pneumatic dilation as the first-line therapeutic approach. In this editorial, the rationale and the evide...

  20. Introduction to contact mechanics

    CERN Document Server

    Fischer-Cripps, Anthony C

    2000-01-01

    Contact mechanics deals with the elastic or plastic contact between two solid objects, and is thus intimately connected with such topics as fracture, hardness, and elasticity.This text, intended for advanced undergraduates, begins with an introduction to the mechanical properties of materials, general fracture mechanics, and fractures in brittle solids.This is followed by a detailed discussion of stresses and the nature of elastic and elastic-plastic contact.

  1. The ZOOM minimization package

    International Nuclear Information System (INIS)

    Fischler, Mark S.; Sachs, D.

    2004-01-01

    A new object-oriented Minimization package is available for distribution in the same manner as CLHEP. This package, designed for use in HEP applications, has all the capabilities of Minuit, but is a re-write from scratch, adhering to modern C++ design principles. A primary goal of this package is extensibility in several directions, so that its capabilities can be kept fresh with as little maintenance effort as possible. This package is distinguished by the priority that was assigned to C++ design issues, and the focus on producing an extensible system that will resist becoming obsolete

  2. Minimizing the Pacman effect

    International Nuclear Information System (INIS)

    Ritson, D.; Chou, W.

    1997-10-01

    The Pacman bunches will experience two deleterious effects: tune shift and orbit displacement. It is known that the tune shift can be compensated by arranging crossing planes 900 relative to each other at successive interaction points (lPs). This paper gives an analytical estimate of the Pacman orbit displacement for a single as well as for two crossings. For the latter, it can be minimized by using equal phase advances from one IP to another. In the LHC, this displacement is in any event small and can be neglected

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial ...

  4. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  5. Colors and contact dermatitis.

    Science.gov (United States)

    Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni

    2014-01-01

    The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.

  6. Immunotherapy of allergic contact dermatitis.

    Science.gov (United States)

    Spiewak, Radoslaw

    2011-08-01

    The term 'immunotherapy' refers to treating diseases by inducing, enhancing or suppressing immune responses. As allergy is an excessive, detrimental immune reaction to otherwise harmless environmental substances, immunotherapy of allergic disease is aimed at the induction of tolerance toward sensitizing antigens. This article focuses on the historical developments, present state and future outlook for immunotherapy with haptens as a therapeutic modality for allergic contact dermatitis. Inspired by the effectiveness of immunotherapy in respiratory allergies, attempts were undertaken at curing allergic contact dermatitis by means of controlled administration of the sensitizing haptens. Animal and human experiments confirmed that tolerance to haptens can be induced most effectively when the induction of tolerance precedes attempted sensitization. In real life, however, therapy is sought by people who are already sensitized and an effective reversal of hypersensitivity seems more difficult to achieve. Decades of research on Rhus hypersensitivity led to a conclusion that immunotherapy can suppress Rhus dermatitis, however, only to a limited degree, for a short period of time, and at a high risk of side effects, which makes this method therapeutically unprofitable. Methodological problems with most available studies of immunotherapy of contact allergy to nickel make any definite conclusions impossible at this stage.

  7. Ransomware: Minimizing the Risks.

    Science.gov (United States)

    Pope, Justin

    2016-01-01

    This ongoing column is dedicated to providing information to our readers on managing legal risks associated with medical practice. We invite questions from our readers. The answers are provided by PRMS, Inc. (www.prms.com), a manager of medical professional liability insurance programs with services that include risk management consultation, education and onsite risk management audits, and other resources to healthcare providers to help improve patient outcomes and reduce professional liability risk. The answers published in this column represent those of only one risk management consulting company. Other risk management consulting companies or insurance carriers may provide different advice, and readers should take this into consideration. The information in this column does not constitute legal advice. For legal advice, contact your personal attorney. Note: The information and recommendations in this article are applicable to physicians and other healthcare professionals so "clinician" is used to indicate all treatment team members.

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care professional. Retailers that sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in pop-up ... contact lenses from a retailer that does not ask for a prescription. ...

  9. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Get follow up exams with your eye care provider. If you notice redness, swelling, excessive discharge, pain or discomfort from wearing contact lenses, remove the lenses and seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ...

  11. Sciences & Nature: Contact

    African Journals Online (AJOL)

    Principal Contact. Ehouan Etienne Ehile Professor University of Abobo-Adjamé 02 BP 801 Abidjan 02. Phone: (+225) 2030 4201. Fax: (+225) 2030 4203. Email: eh_ehile@yahoo.fr. Support Contact. Irie Zoro Bi Email: banhiakalou@yahoo.fr. ISSN: 1812-0741. AJOL African Journals Online. HOW TO USE AJOL.

  12. Contact Us | DOepatents

    Science.gov (United States)

    advance. Your help is appreciated. Contact us by email Email doepatentscomments@osti.gov NOTE: Email us by phone Phone Phone (865) 241-5275 Contact us in writing Mail U.S. Department of Energy Office of non-federal websites. Their policies may differ from this site. Javascript Not Enabled Email Link

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... eye-care team . Consumer warning about the improper use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the FDA? Check the FDA's database of approved contact lenses . Related Stories Prevent Infection ...

  14. Contact dermatitis. A review

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Benezra, C; Burrows, D

    1987-01-01

    In recent years, there has been a dramatic rise in our understanding of contact dermatitis. This paper is a review of our knowledge of the mechanisms involved in contact dermatitis and related phenomena, the investigation of these events and the emergence of significant new allergens during...

  15. Contact Hamiltonian mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bravetti, Alessandro, E-mail: alessandro.bravetti@iimas.unam.mx [Instituto de Investigaciones en Matemáticas Aplicadas y en Sistemas, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Cruz, Hans, E-mail: hans@ciencias.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A. P. 70543, México, DF 04510 (Mexico); Tapias, Diego, E-mail: diego.tapias@nucleares.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, A.P. 70543, México, DF 04510 (Mexico)

    2017-01-15

    In this work we introduce contact Hamiltonian mechanics, an extension of symplectic Hamiltonian mechanics, and show that it is a natural candidate for a geometric description of non-dissipative and dissipative systems. For this purpose we review in detail the major features of standard symplectic Hamiltonian dynamics and show that all of them can be generalized to the contact case.

  16. Contact Quality in Participation

    DEFF Research Database (Denmark)

    Simonsen, Jesper; Jensen, Olav Storm

    2016-01-01

    We investigate the concept of participation from the perspective of quality of the contact in the communicative interactions between participants. We argue for the need for an academic-personal competence that qualifies the human contact central in all Participatory Design (PD) activities as a way...

  17. Nigerian Food Journal: Contact

    African Journals Online (AJOL)

    Nigerian Food Journal. ... Nigerian Food Journal: Contact. Journal Home > About the Journal > Nigerian Food Journal: Contact. Log in or Register to get access to full text downloads. ... Mailing Address. Department of Food Science and Technology University of Agriculture, Makurdi, Nigeria ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...

  19. Minimization of PWR reactor control rods wear

    International Nuclear Information System (INIS)

    Ponzoni Filho, Pedro; Moura Angelkorte, Gunther de

    1995-01-01

    The Rod Cluster Control Assemblies (RCCA's) of Pressurized Water Reactors (PWR's) have experienced a continuously wall cladding wear when Reactor Coolant Pumps (RCP's) are running. Fretting wear is a result of vibrational contact between RCCA rodlets and the guide cards which provide lateral support for the rodlets when RCCA's are withdrawn from the core. A procedure is developed to minimize the rodlets wear, by the shuffling and axial reposition of RCCA's every operating cycle. These shuffling and repositions are based on measurement of the rodlet cladding thickness of all RCCA's. (author). 3 refs, 2 figs, 2 tabs

  20. Contact materials for nanoelectronics

    KAUST Repository

    Alshareef, Husam N.

    2011-02-01

    In this article, we review current research activities in contact material development for electronic and nanoelectronic devices. A fundamental issue in contact materials research is to understand and control interfacial reactions and phenomena that modify the expected device performance. These reactions have become more challenging and more difficult to control as new materials have been introduced and as device sizes have entered the deep nanoscale. To provide an overview of this field of inquiry, this issue of MRS Bulletin includes articles on gate and contact materials for Si-based devices, junction contact materials for Si-based devices, and contact materials for alternate channel substrates (Ge and III-V), nanodevices. © 2011 Materials Research Society.

  1. Noneczematous Contact Dermatitis

    Science.gov (United States)

    Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni

    2013-01-01

    Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520

  2. Minimal conformal model

    Energy Technology Data Exchange (ETDEWEB)

    Helmboldt, Alexander; Humbert, Pascal; Lindner, Manfred; Smirnov, Juri [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2016-07-01

    The gauge hierarchy problem is one of the crucial drawbacks of the standard model of particle physics (SM) and thus has triggered model building over the last decades. Its most famous solution is the introduction of low-scale supersymmetry. However, without any significant signs of supersymmetric particles at the LHC to date, it makes sense to devise alternative mechanisms to remedy the hierarchy problem. One such mechanism is based on classically scale-invariant extensions of the SM, in which both the electroweak symmetry and the (anomalous) scale symmetry are broken radiatively via the Coleman-Weinberg mechanism. Apart from giving an introduction to classically scale-invariant models, the talk presents our results on obtaining a theoretically consistent minimal extension of the SM, which reproduces the correct low-scale phenomenology.

  3. Minimal Reducts with Grasp

    Directory of Open Access Journals (Sweden)

    Iris Iddaly Mendez Gurrola

    2011-03-01

    Full Text Available The proper detection of patient level of dementia is important to offer the suitable treatment. The diagnosis is based on certain criteria, reflected in the clinical examinations. From these examinations emerge the limitations and the degree in which each patient is in. In order to reduce the total of limitations to be evaluated, we used the rough set theory, this theory has been applied in areas of the artificial intelligence such as decision analysis, expert systems, knowledge discovery, classification with multiple attributes. In our case this theory is applied to find the minimal limitations set or reduct that generate the same classification that considering all the limitations, to fulfill this purpose we development an algorithm GRASP (Greedy Randomized Adaptive Search Procedure.

  4. Minimally extended SILH

    International Nuclear Information System (INIS)

    Chala, Mikael; Grojean, Christophe; Humboldt-Univ. Berlin; Lima, Leonardo de; Univ. Estadual Paulista, Sao Paulo

    2017-03-01

    Higgs boson compositeness is a phenomenologically viable scenario addressing the hierarchy problem. In minimal models, the Higgs boson is the only degree of freedom of the strong sector below the strong interaction scale. We present here the simplest extension of such a framework with an additional composite spin-zero singlet. To this end, we adopt an effective field theory approach and develop a set of rules to estimate the size of the various operator coefficients, relating them to the parameters of the strong sector and its structural features. As a result, we obtain the patterns of new interactions affecting both the new singlet and the Higgs boson's physics. We identify the characteristics of the singlet field which cause its effects on Higgs physics to dominate over the ones inherited from the composite nature of the Higgs boson. Our effective field theory construction is supported by comparisons with explicit UV models.

  5. Minimally extended SILH

    Energy Technology Data Exchange (ETDEWEB)

    Chala, Mikael [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Valencia Univ. (Spain). Dept. de Fisica Teorica y IFIC; Durieux, Gauthier; Matsedonskyi, Oleksii [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Grojean, Christophe [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Humboldt-Univ. Berlin (Germany). Inst. fuer Physik; Lima, Leonardo de [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Univ. Estadual Paulista, Sao Paulo (Brazil). Inst. de Fisica Teorica

    2017-03-15

    Higgs boson compositeness is a phenomenologically viable scenario addressing the hierarchy problem. In minimal models, the Higgs boson is the only degree of freedom of the strong sector below the strong interaction scale. We present here the simplest extension of such a framework with an additional composite spin-zero singlet. To this end, we adopt an effective field theory approach and develop a set of rules to estimate the size of the various operator coefficients, relating them to the parameters of the strong sector and its structural features. As a result, we obtain the patterns of new interactions affecting both the new singlet and the Higgs boson's physics. We identify the characteristics of the singlet field which cause its effects on Higgs physics to dominate over the ones inherited from the composite nature of the Higgs boson. Our effective field theory construction is supported by comparisons with explicit UV models.

  6. CpG oligodeoxynucleotides are effective in therapy of minimal residual tumour disease after chemotherapy or surgery in a murine model of MHC class I-deficient, HPV16-associated tumours

    Czech Academy of Sciences Publication Activity Database

    Reiniš, Milan; Šímová, Jana; Indrová, Marie; Bieblová, Jana; Bubeník, Jan

    2007-01-01

    Roč. 30, č. 5 (2007), s. 1247-1251 ISSN 1019-6439 R&D Projects: GA ČR GA301/04/0492; GA ČR GA301/06/0774 EU Projects: European Commission(XE) 18933 - CLINIGENE Grant - others:Liga proti rakovině, Praha(CZ) XX Institutional research plan: CEZ:AV0Z50520514 Keywords : HPV 16 * minimal residual tumour disease * CpG oligonucleotides Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.295, year: 2007

  7. Chronic Morel-Lavallée Lesion: A Novel Minimally Invasive Method of Treatment.

    Science.gov (United States)

    Mettu, Ramireddy; Surath, Harsha Vardhan; Chayam, Hanumantha Rao; Surath, Amaranth

    2016-11-01

    A Morel-Lavallée lesion is a closed internal degloving injury resulting from a shearing force applied to the skin. The etiology of this condition may be motor vehicle accidents, falls, contact sports (ie, football, wrestling),1 and iatrogenic after mammoplasty or abdominal liposuction.2 Common sites of the lesions include the pelvis and/or thigh.3 Isolated Morel-Lavallée lesions without underlying fracture are likely to be missed, which result in chronicity. Management of this condition often requires extensive surgical procedures such as debridement, sclerotherapy, serial percutaneous drainage, negative pressure wound therapy (NPWT), and skin grafting.4,5 The authors wish to highlight a minimally invasive technique for the treatment of chronic Morel-Lavallée lesions.

  8. Contacts to semiconductors

    International Nuclear Information System (INIS)

    Tove, P.A.

    1975-08-01

    Contacts to semiconductors play an important role in most semiconductor devices. These devices range from microelectronics to power components, from high-sensitivity light or radiation detectors to light-emitting of microwave-generating components. Silicon is the dominating material but compound semiconductors are increasing in importance. The following survey is an attempt to classify contact properties and the physical mechanisms involved, as well as fabrication methods and methods of investigation. The main interest is in metal-semiconductor type contacts where a few basic concepts are dealt with in some detail. (Auth.)

  9. Minimal Marking: A Success Story

    Science.gov (United States)

    McNeilly, Anne

    2014-01-01

    The minimal-marking project conducted in Ryerson's School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The "minimal-marking" concept (Haswell, 1983), which requires…

  10. Swarm robotics and minimalism

    Science.gov (United States)

    Sharkey, Amanda J. C.

    2007-09-01

    Swarm Robotics (SR) is closely related to Swarm Intelligence, and both were initially inspired by studies of social insects. Their guiding principles are based on their biological inspiration and take the form of an emphasis on decentralized local control and communication. Earlier studies went a step further in emphasizing the use of simple reactive robots that only communicate indirectly through the environment. More recently SR studies have moved beyond these constraints to explore the use of non-reactive robots that communicate directly, and that can learn and represent their environment. There is no clear agreement in the literature about how far such extensions of the original principles could go. Should there be any limitations on the individual abilities of the robots used in SR studies? Should knowledge of the capabilities of social insects lead to constraints on the capabilities of individual robots in SR studies? There is a lack of explicit discussion of such questions, and researchers have adopted a variety of constraints for a variety of reasons. A simple taxonomy of swarm robotics is presented here with the aim of addressing and clarifying these questions. The taxonomy distinguishes subareas of SR based on the emphases and justifications for minimalism and individual simplicity.

  11. Minimal dilaton model

    Directory of Open Access Journals (Sweden)

    Oda Kin-ya

    2013-05-01

    Full Text Available Both the ATLAS and CMS experiments at the LHC have reported the observation of the particle of mass around 125 GeV which is consistent to the Standard Model (SM Higgs boson, but with an excess of events beyond the SM expectation in the diphoton decay channel at each of them. There still remains room for a logical possibility that we are not seeing the SM Higgs but something else. Here we introduce the minimal dilaton model in which the LHC signals are explained by an extra singlet scalar of the mass around 125 GeV that slightly mixes with the SM Higgs heavier than 600 GeV. When this scalar has a vacuum expectation value well beyond the electroweak scale, it can be identified as a linearly realized version of a dilaton field. Though the current experimental constraints from the Higgs search disfavors such a region, the singlet scalar model itself still provides a viable alternative to the SM Higgs in interpreting its search results.

  12. Minimal mirror twin Higgs

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Riccardo [Institute of Theoretical Studies, ETH Zurich,CH-8092 Zurich (Switzerland); Scuola Normale Superiore,Piazza dei Cavalieri 7, 56126 Pisa (Italy); Hall, Lawrence J.; Harigaya, Keisuke [Department of Physics, University of California,Berkeley, California 94720 (United States); Theoretical Physics Group, Lawrence Berkeley National Laboratory,Berkeley, California 94720 (United States)

    2016-11-29

    In a Mirror Twin World with a maximally symmetric Higgs sector the little hierarchy of the Standard Model can be significantly mitigated, perhaps displacing the cutoff scale above the LHC reach. We show that consistency with observations requires that the Z{sub 2} parity exchanging the Standard Model with its mirror be broken in the Yukawa couplings. A minimal such effective field theory, with this sole Z{sub 2} breaking, can generate the Z{sub 2} breaking in the Higgs sector necessary for the Twin Higgs mechanism. The theory has constrained and correlated signals in Higgs decays, direct Dark Matter Detection and Dark Radiation, all within reach of foreseen experiments, over a region of parameter space where the fine-tuning for the electroweak scale is 10-50%. For dark matter, both mirror neutrons and a variety of self-interacting mirror atoms are considered. Neutrino mass signals and the effects of a possible additional Z{sub 2} breaking from the vacuum expectation values of B−L breaking fields are also discussed.

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not been properly fitted by an eye care professional, the lenses stuck to my eye like a ... prescription and proper fitting by an eye-care professional. Retailers that sell contacts without a prescription are ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  15. Contact Line Dynamics

    Science.gov (United States)

    Kreiss, Gunilla; Holmgren, Hanna; Kronbichler, Martin; Ge, Anthony; Brant, Luca

    2017-11-01

    The conventional no-slip boundary condition leads to a non-integrable stress singularity at a moving contact line. This makes numerical simulations of two-phase flow challenging, especially when capillarity of the contact point is essential for the dynamics of the flow. We will describe a modeling methodology, which is suitable for numerical simulations, and present results from numerical computations. The methodology is based on combining a relation between the apparent contact angle and the contact line velocity, with the similarity solution for Stokes flow at a planar interface. The relation between angle and velocity can be determined by theoretical arguments, or from simulations using a more detailed model. In our approach we have used results from phase field simulations in a small domain, but using a molecular dynamics model should also be possible. In both cases more physics is included and the stress singularity is removed.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... away without suffering an eye injury. However, the natural protective mechanisms of the eye – such as the ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... a laser pointer several times, according to a report published this month in the New England Journal ...

  18. SAM Technical Contacts

    Science.gov (United States)

    These technical contacts are available to help with questions regarding method deviations, modifications, sample problems or interferences, quality control requirements, the use of alternative methods, or the need to address analytes or sample types.

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are ... this month in the New England Journal of Medicine. Unfortunately, this kind of injury is all too ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... a souvenir shop, but 10 hours after she first put in a pair of colored contact lenses, ... APR 24, 2018 By Kate Rauch In a first, scientists in China have created artificial photoreceptors to ...

  1. GAS-FOVEAL CONTACT

    DEFF Research Database (Denmark)

    Alberti, Mark; la Cour, Morten

    2018-01-01

    PURPOSE: To compare gas-foveal contact in face-down positioning (FDP) and nonsupine positioning (NSP), to analyze causes of gas-foveal separation and to determine how gas-foveal contact affects clinical outcome after idiopathic macular hole repair. METHODS: Single center, randomized controlled...... study. Participants with an idiopathic macular hole were allocated to either FDP or NSP. Primary outcome was gas-foveal contact, calculated by analyzing positioning in relation to intraocular gas fill. Positioning was measured with an electronic device recording positioning for 72 hours postoperatively....... RESULTS: Positioning data were available for 33/35 in the FDP group and 35/37 in the NSP group, thus results are based on 68 analyzed participants. Median gas-foveal contact was 99.82% (range 73.6-100.0) in the FDP group and 99.57% (range 85.3-100.0) in the NSP group (P = 0.22). In a statistical model...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours after ... are being sold illegally," Dr. Steinemann said. Never buy colored contact lenses from a retailer that does ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ... 2018 By Dan T. Gudgel Do you know what the difference is between ophthalmologists and optometrists? A ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Halloween or any time of year, follow these guidelines: Get an eye exam from a licensed eye ... available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ... require the same level of care or consideration as a standard contact lens because they can be ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... seek immediate medical attention from an ophthalmologist. Related resources: Learn how to properly care for contact lenses . ... have given blind patients some functional vision, using human embryonic stem cells. Two blind patients regained enough ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... that decorative lenses do not require the same level of care or consideration as a standard contact ... By Kate Rauch In a small but intriguing study, scientists in England have given blind patients some ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from the truth." Real People, Real Problems with Colored Contact Lenses Julian: Teenager Blinded In ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... With Proper Contact Lens Care Apr 23, 2018 Solar Eclipse Inflicts Damage in the Shape of the ... edging closer, thanks to a wave of new technologies aiming to fix failing eye parts with human- ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... videos on your website Promotional materials for eye health observances EyeSmart resources are also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... valid prescription that includes the brand name, lens measurements, and expiration date. Purchase the colored contact lenses ... with human-made versions. U.S. News Highlights the Value of Ophthalmologists APR 20, 2018 By Dan T. ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... 13, 2017 Histoplasmosis Diagnosis Sep 01, 2017 How common is retinal detachment for people with high myopia? ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Eye Health A-Z Symptoms Glasses & Contacts Tips & ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the ... Service For Advertisers For Media Ophthalmology Job Center © American ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About ...

  19. Ergonomics SA: Contact

    African Journals Online (AJOL)

    Principal Contact. Mrs June McDougall. Rhodes University. Department of Human Kinetics and Ergonomics. P.O. Box 94. Rhodes University. Grahamstown. 6140. Phone: +27 46 6038471. Email: j.mcdougall@ru.ac.za ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by ... 23, 2018 Solar Eclipse Inflicts Damage in the Shape of ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses to enhance their costumes. From blood-drenched vampire eyes to glow-in-the-dark ... properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to the journals may be interrupted during this time. We are working to resolve the issue quickly ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... the United States. All contact lenses are medical devices that require a prescription and proper fitting by ... Care Apr 23, 2018 How long does it take the eye to go back to its original ...

  5. Tomato contact dermatitis

    DEFF Research Database (Denmark)

    Paulsen, Evy; Christensen, Lars P; Andersen, Klaus Ejner

    2012-01-01

    The tomato plant (Solanum lycopersicum) is an important crop worldwide. Whereas immediate-type reactions to tomato fruits are well known, contact dermatitis caused by tomatoes or tomato plants is rarely reported. The aims of this study were to present new data on contact sensitization to tomato...... plants and review the literature on contact dermatitis caused by both plants and fruits. An ether extract of tomato plants made as the original oleoresin plant extracts, was used in aimed patch testing, and between 2005 and 2011. 8 of 93 patients (9%) tested positive to the oleoresin extracts....... This prevalence is in accordance with the older literature that reports tomato plants as occasional sensitizers. The same applies to tomato fruits, which, in addition, may cause protein contact dermatitis. The allergens of the plant are unknown, but both heat-stable and heat-labile constituents seem...

  6. Fragrance allergic contact dermatitis.

    Science.gov (United States)

    Cheng, Judy; Zug, Kathryn A

    2014-01-01

    Fragrances are a common cause of allergic contact dermatitis in Europe and in North America. They can affect individuals at any age and elicit a spectrum of reactions from contact urticaria to systemic contact dermatitis. Growing recognition of the widespread use of fragrances in modern society has fueled attempts to prevent sensitization through improved allergen identification, labeling, and consumer education. This review provides an overview and update on fragrance allergy. Part 1 discusses the epidemiology and evaluation of suspected fragrance allergy. Part 2 reviews screening methods, emerging fragrance allergens, and management of patients with fragrance contact allergy. This review concludes by examining recent legislation on fragrances and suggesting potential additions to screening series to help prevent and detect fragrance allergy.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... also available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmology/Strabismus Ocular Pathology/Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus ... Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without ...

  15. Lettuce contact allergy.

    Science.gov (United States)

    Paulsen, Evy; Andersen, Klaus E

    2016-02-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil

    2008-01-01

    Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....

  17. Feasibility of Using a Novel 2.45 GHz Double Short Distance Slot Coaxial Antenna for Minimally Invasive Cancer Breast Microwave Ablation Therapy: Computational Model, Phantom, and In Vivo Swine Experimentation

    Science.gov (United States)

    Cepeda Rubio, M. F. J.; Leija, L.

    2018-01-01

    Microwave ablation (MWA) by using coaxial antennas is a promising alternative for breast cancer treatment. A double short distance slot coaxial antenna as a newly optimized applicator for minimally invasive treatment of breast cancer is proposed. To validate and to analyze the feasibility of using this method in clinical treatment, a computational model, phantom, and breast swine in vivo experimentation were carried out, by using four microwave powers (50 W, 30 W, 20 W, and 10 W). The finite element method (FEM) was used to develop the computational model. Phantom experimentation was carried out in breast phantom. The in vivo experimentation was carried out in a 90 kg swine sow. Tissue damage was estimated by comparing control and treated micrographs of the porcine mammary gland samples. The coaxial slot antenna was inserted in swine breast glands by using image-guided ultrasound. In all cases, modeling, in vivo and phantom experimentation, and ablation temperatures (above 60°C) were reached. The in vivo experiments suggest that this new MWA applicator could be successfully used to eliminate precise and small areas of tissue (around 20–30 mm2). By modulating the power and time applied, it may be possible to increase/decrease the ablation area. PMID:29854360

  18. Rough Surface Contact

    Directory of Open Access Journals (Sweden)

    T Nguyen

    2017-06-01

    Full Text Available This paper studies the contact of general rough curved surfaces having nearly identical geometries, assuming the contact at each differential area obeys the model proposed by Greenwood and Williamson. In order to account for the most general gross geometry, principles of differential geometry of surface are applied. This method while requires more rigorous mathematical manipulations, the fact that it preserves the original surface geometries thus makes the modeling procedure much more intuitive. For subsequent use, differential geometry of axis-symmetric surface is considered instead of general surface (although this “general case” can be done as well in Chapter 3.1. The final formulas for contact area, load, and frictional torque are derived in Chapter 3.2.

  19. Acrylate Systemic Contact Dermatitis.

    Science.gov (United States)

    Sauder, Maxwell B; Pratt, Melanie D

    2015-01-01

    Acrylates, the 2012 American Contact Dermatitis Society allergen of the year, are found in a range of products including the absorbent materials within feminine hygiene pads. When fully polymerized, acrylates are nonimmunogenic; however, if not completely cured, the monomers can be potent allergens.A 28-year-old woman is presented, who had her teeth varnished with Isodan (Septodont, Saint-Maur-des-Fossés, France) containing HEMA (2-hydroxyethyl methacrylate) with no initial reaction. Approximately 1 month later, the patient developed a genital dermatitis secondary to her feminine hygiene pads. The initial reaction resolved, but 5 months later, the patient developed a systemic contact dermatitis after receiving a second varnishing.The patient was dramatically patch test positive to many acrylates. This case demonstrates a reaction to likely unpolymerized acrylates within a feminine hygiene pad, as well as broad cross-reactivity or cosensitivity to acrylates, and possibly a systemic contact dermatitis with systemic re-exposure to unpolymerized acrylates.

  20. ALLERGIC CONTACT DERMATITIS

    Directory of Open Access Journals (Sweden)

    Trisna Yuliharti Tersinanda

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Allergic contact dermatitis is an immunologic reaction that tends to involve the surrounding skin and may even spread beyond affected sites. This skin disease is one of the more frequent, and costly dermatologic problems. Recent data from United Kingdom and United States suggest that the percentage of occupational contact dermatitis due to allergy may be much higher, thus raising the economic impact of occupational allergic contact dermatitis. There is not enough data about the epidemiology of allergic contact dermatitis in Indonesia, however based on research that include beautician in Denpasar, about 27,6 percent had side effect of cosmetics, which is 25,4 percent of it manifested as allergic contact dermatitis. Diagnosis of allergic contact dermatitis is based on anamnesis, physical examination, patch test, and this disease should be distinguished from other eczematous skin disease. The management is prevention of allergen exposure, symptomatic treatment, and physicochemical barrier /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  1. Minimal residual disease in chronic lymphocytic leukaemia.

    Science.gov (United States)

    García Vela, José Antonio; García Marco, José Antonio

    2018-02-23

    Minimal residual disease (MRD) assessment is an important endpoint in the treatment of chronic lymphocytic leukaemia (CLL). It is highly predictive of prolonged progression-free survival (PFS) and overall survival and could be considered a surrogate for PFS in the context of chemoimmunotherapy based treatment. Evaluation of MRD level by flow cytometry or molecular techniques in the era of the new BCR and Bcl-2 targeted inhibitors could identify the most cost-effective and durable treatment sequencing. A therapeutic approach guided by the level of MRD might also determine which patients would benefit from an early stop or consolidation therapy. In this review, we discuss the different MRD methods of analysis, which source of tumour samples must be analysed, the future role of the detection of circulating tumour DNA, and the potential role of MRD negativity in clinical practice in the modern era of CLL therapy. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  2. Global Analysis of Minimal Surfaces

    CERN Document Server

    Dierkes, Ulrich; Tromba, Anthony J

    2010-01-01

    Many properties of minimal surfaces are of a global nature, and this is already true for the results treated in the first two volumes of the treatise. Part I of the present book can be viewed as an extension of these results. For instance, the first two chapters deal with existence, regularity and uniqueness theorems for minimal surfaces with partially free boundaries. Here one of the main features is the possibility of 'edge-crawling' along free parts of the boundary. The third chapter deals with a priori estimates for minimal surfaces in higher dimensions and for minimizers of singular integ

  3. Minimal Surfaces for Hitchin Representations

    DEFF Research Database (Denmark)

    Li, Qiongling; Dai, Song

    2018-01-01

    . In this paper, we investigate the properties of immersed minimal surfaces inside symmetric space associated to a subloci of Hitchin component: $q_n$ and $q_{n-1}$ case. First, we show that the pullback metric of the minimal surface dominates a constant multiple of the hyperbolic metric in the same conformal...... class and has a strong rigidity property. Secondly, we show that the immersed minimal surface is never tangential to any flat inside the symmetric space. As a direct corollary, the pullback metric of the minimal surface is always strictly negatively curved. In the end, we find a fully decoupled system...

  4. Perspectives on setting limits for RF contact currents: a commentary.

    Science.gov (United States)

    Tell, Richard A; Tell, Christopher A

    2018-01-15

    Limits for exposure to radiofrequency (RF) contact currents are specified in the two dominant RF safety standards and guidelines developed by the Institute of Electrical and Electronics Engineers (IEEE) and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These limits are intended to prevent RF burns when contacting RF energized objects caused by high local tissue current densities. We explain what contact currents are and review some history of the relevant limits with an emphasis on so-called "touch" contacts, i.e., contact between a person and a contact current source during touch via a very small contact area. Contact current limits were originally set on the basis of controlling the specific absorption rate resulting from the current flowing through regions of small conductive cross section within the body, such as the wrist or ankle. More recently, contact currents have been based on thresholds of perceived heating. In the latest standard from the IEEE developed for NATO, contact currents have been based on two research studies in which thresholds for perception of thermal warmth or thermal pain have been measured. Importantly, these studies maximized conductive contact between the subject and the contact current source. This factor was found to dominate the response to heating wherein high resistance contact, such as from dry skin, can result in local heating many times that from a highly conductive contact. Other factors such as electrode size and shape, frequency of the current and the physical force associated with contact are found to introduce uncertainty in threshold values when comparing data across multiple studies. Relying on studies in which the contact current is minimized for a given threshold does not result in conservative protection limits. Future efforts to develop limits on contact currents should include consideration of (1) the basis for the limits (perception, pain, tissue damage); (2) understanding of the

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers ... Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far from the truth." ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are considering buying approved by the ... Service For Advertisers For Media Ophthalmology Job Center © American ...

  9. Fermilab | Contact Fermilab

    Science.gov (United States)

    Education Safety Sustainability and Environment Contact Related Links DOE FRA UChicago URA Newsroom -840-3000 Fax: 630-840-4343 Shipping address Fermilab Receiving Wilson Street and Kirk Road Batavia IL 60510-5011 Phone: 630-840-3000 Visiting address Fermilab entrance Kirk Road and Pine Street Batavia IL

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ...

  11. Lettuce contact allergy

    DEFF Research Database (Denmark)

    Paulsen, Evy; Andersen, Klaus E

    2016-01-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present...... person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy.......Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present...... new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22...

  12. Contact allergy to spices

    NARCIS (Netherlands)

    W. Van den Akker Th. (W.); I.D. Roesyanto-Mahadi (I.); A.W. van Toorenenbergen (Albert); Th. van Joost (Theo)

    1990-01-01

    textabstractA group of 103 patients suspected of contact allergy was tested with the European standard series, wood tars and spices; paprika, cinnamon, laurel, celery seed, nutmeg, curry, black pepper, cloves, while pepper, coriander, cacao and garlic. 32 patients (Group I) were selected on the

  13. Fermilab Education Office - Contacts

    Science.gov (United States)

    Search The Office of Education and Public Outreach: Contacts All telephone numbers require area code Presentations for Presenters 840-3094 Office of Education and Public Outreach Spencer Pasero spasero@fnal.gov Education Office 840-3076 Fermilab Friends for Science Education General Questions Susan Dahl sdahl@fnal.gov

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... A medical degree and many more years of training, for starters. A recent article from U.S. News and World Report explains what ophthalmologists are and how they can help you look after ... Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  15. Mathematics Connection: Contact

    African Journals Online (AJOL)

    Principal Contact. Dr. Kofi Mereku Executive Editor Department of Mathematics Education, UCE Mathematical Association of Ghana, C/o Department of Mathematics Education University College of Education of Winneba P. O. Box 25, Winneba, Ghana Phone: +233244961318. Email: dkmereku@uew.edu.gh ...

  16. Contact activation: a revision.

    Science.gov (United States)

    Schmaier, A H

    1997-07-01

    In conclusion, a revised view of the contact system has been presented. This system has little to do with the initiation of hemostasis. Like lupus anticoagulants, deficiencies of contact proteins give prolonged APTTs but may be risk factors for thrombosis. BK from kininogens is a potent modulator of vascular biology inducing vasodilation, tissue plasminogen activator release, and prostacyclin liberation. Kininogens, themselves, are selective inhibitors of alpha-thrombin-induced platelet activation preventing alpha-thrombin from cleaving the cloned thrombin receptor after arginine41. Kininogens' alpha-thrombin inhibitory activity exists in intact kininogens, BK, and all of BK's breakdown products. HK also is the pivotal protein for contact protein assembly on endothelium. It is the receptor for prekallikrein which when bound to HK becomes activated to kallikrein by an endothelial cell enzyme system independent of activated forms of plasma factor XII. Prekallikrein activation on endothelial cells results in kinetically favorable single chain urokinase and plasminogen activation. Thus the "physiologic, negatively charged surface" for contact system activation is really the assembly of these proteins on cell membranes and activation by membrane-associated enzymes.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  18. Language Contact and Bilingualism

    NARCIS (Netherlands)

    Appel, René; Muysken, Pieter

    2006-01-01

    What happens - sociologically, linguistically, educationally, politically - when more than one language is in regular use in a community? How do speakers handle these languages simultaneously, and what influence does this language contact have on the languages involved? Although most people in the

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but 10 hours ...

  20. Pizza makers' contact dermatitis.

    Science.gov (United States)

    Lembo, Serena; Lembo, Claudio; Patruno, Cataldo; Balato, Anna; Balato, Nicola; Ayala, Fabio

    2014-01-01

    Contact eczema to foods, spices, and food additives can occur in occupational and nonoccupational settings in those who grow, handle, prepare, or cook food. Pizza is one of the most eaten foods in every continent, and pizza making is a common work in many countries. We aimed to evaluate the occurrence and the causes of contact dermatitis in pizza makers in Naples. We performed an observational study in 45 pizza makers: all the enrolled subjects had to answer a questionnaire designed to detect personal history of respiratory or cutaneous allergy, atopy; work characteristics and timing were also investigated. Every subject attended the dermatology clinic for a complete skin examination, and when needed, patients were patch tested using the Italian baseline series of haptens integrated with an arbitrary pizza makers series. Our results reported that 13.3% of the enrolled pizza makers (6/45) presented hand eczema, and that 8.9% (4/45) were affected by occupational allergic contact dermatitis. Diallyl disulfide and ammonium persulfate were the responsible substances. Performing patch tests in pizza makers and food handlers affected by hand contact dermatitis is useful. We propose a specific series of haptens for this wide working category.

  1. Contact: Releasing the news

    Science.gov (United States)

    Pinotti, Roberto

    The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.

  2. Rigid Bodies in Contact

    DEFF Research Database (Denmark)

    Niebe, Sarah Maria

    . A contact point determination method, based on boolean surface maps, is developed to handle collisions between tetrahedral meshes. The novel nonsmooth nonlinear conjugate gradient (NNCG) method is presented. The NNCG method is comparable in terms of accuracy to the state-of-the-art method, projected Gauss...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into ...

  4. Contact allergy to cosmetics

    DEFF Research Database (Denmark)

    Held, E; Johansen, J D; Agner, T

    1999-01-01

    In a 2-year period, 1527 patients with contact dermatitis were investigated in the patch-test clinic. In 531 patients, allergy to cosmetics was suspected from the history and they were tested with their own cosmetic products. 40 (7.5%) (of the 531 patients) had 1 or more positive reactions, 82 (15...

  5. Ghana Mining Journal: Contact

    African Journals Online (AJOL)

    Principal Contact. Professor Daniel Mireku-Gyimah Editor-in-Chief University of Mines & Technology Ghana Mining Journal University of Mines & Technology P. O. BOX 237 Tarkwa Ghana Phone: +233 362 20280/20324. Fax: +233 362 20306. Email: dm.gyimah@umat.edu.gh ...

  6. Molecular dynamics study of contact mechanics: contact area and interfacial separation from small to full contact

    OpenAIRE

    Yang, C.; Persson, B. N. J.

    2007-01-01

    We report a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. We study the contact area and the interfacial separation from small contact (low load) to full contact (high load). For small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For high load the contact area approaches to the nominal contact area (i.e., complete contact), and the i...

  7. Guidelines for mixed waste minimization

    International Nuclear Information System (INIS)

    Owens, C.

    1992-02-01

    Currently, there is no commercial mixed waste disposal available in the United States. Storage and treatment for commercial mixed waste is limited. Host States and compacts region officials are encouraging their mixed waste generators to minimize their mixed wastes because of management limitations. This document provides a guide to mixed waste minimization

  8. Minimal changes in health status questionnaires: distinction between minimally detectable change and minimally important change

    Directory of Open Access Journals (Sweden)

    Knol Dirk L

    2006-08-01

    Full Text Available Abstract Changes in scores on health status questionnaires are difficult to interpret. Several methods to determine minimally important changes (MICs have been proposed which can broadly be divided in distribution-based and anchor-based methods. Comparisons of these methods have led to insight into essential differences between these approaches. Some authors have tried to come to a uniform measure for the MIC, such as 0.5 standard deviation and the value of one standard error of measurement (SEM. Others have emphasized the diversity of MIC values, depending on the type of anchor, the definition of minimal importance on the anchor, and characteristics of the disease under study. A closer look makes clear that some distribution-based methods have been merely focused on minimally detectable changes. For assessing minimally important changes, anchor-based methods are preferred, as they include a definition of what is minimally important. Acknowledging the distinction between minimally detectable and minimally important changes is useful, not only to avoid confusion among MIC methods, but also to gain information on two important benchmarks on the scale of a health status measurement instrument. Appreciating the distinction, it becomes possible to judge whether the minimally detectable change of a measurement instrument is sufficiently small to detect minimally important changes.

  9. Waste minimization handbook, Volume 1

    International Nuclear Information System (INIS)

    Boing, L.E.; Coffey, M.J.

    1995-12-01

    This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility's life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996

  10. Waste minimization handbook, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Boing, L.E.; Coffey, M.J.

    1995-12-01

    This technical guide presents various methods used by industry to minimize low-level radioactive waste (LLW) generated during decommissioning and decontamination (D and D) activities. Such activities generate significant amounts of LLW during their operations. Waste minimization refers to any measure, procedure, or technique that reduces the amount of waste generated during a specific operation or project. Preventive waste minimization techniques implemented when a project is initiated can significantly reduce waste. Techniques implemented during decontamination activities reduce the cost of decommissioning. The application of waste minimization techniques is not limited to D and D activities; it is also useful during any phase of a facility`s life cycle. This compendium will be supplemented with a second volume of abstracts of hundreds of papers related to minimizing low-level nuclear waste. This second volume is expected to be released in late 1996.

  11. Minimal Webs in Riemannian Manifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen

    2008-01-01

    For a given combinatorial graph $G$ a {\\it geometrization} $(G, g)$ of the graph is obtained by considering each edge of the graph as a $1-$dimensional manifold with an associated metric $g$. In this paper we are concerned with {\\it minimal isometric immersions} of geometrized graphs $(G, g......)$ into Riemannian manifolds $(N^{n}, h)$. Such immersions we call {\\em{minimal webs}}. They admit a natural 'geometric' extension of the intrinsic combinatorial discrete Laplacian. The geometric Laplacian on minimal webs enjoys standard properties such as the maximum principle and the divergence theorems, which...... are of instrumental importance for the applications. We apply these properties to show that minimal webs in ambient Riemannian spaces share several analytic and geometric properties with their smooth (minimal submanifold) counterparts in such spaces. In particular we use appropriate versions of the divergence...

  12. Influence of Thermal Effects During Blade-Casing Contact Experiments

    OpenAIRE

    Millecamps , Antoine; Brunel , Jean-François; Dufrenoy , Philippe; Garcin , François; Nucci , Marco

    2009-01-01

    International audience; In rotating machinery, notably in modern high efficiency compressors, a critical requirement for optimal performance consists in minimizing radial clearances between the rotating bladed disk and the casing. This solution significantly increases the risks of contact between rotating bladed disk and casing and may lead in specific conditions to catastrophic behavior (component failure, etc.). The physical phenomena and mechanisms involved in blade-casing contact interact...

  13. [Theory and practice of minimally invasive endodontics].

    Science.gov (United States)

    Jiang, H W

    2016-08-01

    The primary goal of modern endodontic therapy is to achieve the long-term retention of a functional tooth by preventing or treating pulpitis or apical periodontitis is. The long-term retention of endodontically treated tooth is correlated with the remaining amount of tooth tissue and the quality of the restoration after root canal filling. In recent years, there has been rapid progress and development in the basic research of endodontic biology, instrument and applied materials, making treatment procedures safer, more accurate, and more efficient. Thus, minimally invasive endodontics(MIE)has received increasing attention at present. MIE aims to preserve the maximum of tooth structure during root canal therapy, and the concept covers the whole process of diagnosis and treatment of teeth. This review article focuses on describing the minimally invasive concepts and operating essentials in endodontics, from diagnosis and treatment planning to the access opening, pulp cavity finishing, root canal cleaning and shaping, 3-dimensional root canal filling and restoration after root canal treatment.

  14. Focusing on Contact Lens Safety

    Science.gov (United States)

    ... their practices. Decorative contacts (also called “costume,” colored,” “fashion,” or “plano” contacts). The FDA has often warned ... Lenses Decorative Contact Lenses Hydrogen Peroxide Solution Related Consumer Updates 'Colored' and Decorative Contact Lenses: A Prescription ...

  15. Electrical contacts principles and applications

    CERN Document Server

    Slade, Paul G

    2013-01-01

    Covering the theory, application, and testing of contact materials, Electrical Contacts: Principles and Applications, Second Edition introduces a thorough discussion on making electric contact and contact interface conduction; presents a general outline of, and measurement techniques for, important corrosion mechanisms; considers the results of contact wear when plug-in connections are made and broken; investigates the effect of thin noble metal plating on electronic connections; and relates crucial considerations for making high- and low-power contact joints. It examines contact use in switch

  16. [News on occupational contact dermatitis].

    Science.gov (United States)

    Crépy, Marie-Noëlle; Bensefa-Colas, Lynda

    2014-03-01

    Contact dermatitis--irritant contact dermatitis, allergic contact dermatitis and protein contact dermatitis--are the most common occupational skin diseases, most often localized to the hands. Contact urticaria is rarer The main occupational irritants are wet work, detergents and disinfectants, cutting oils, and solvents. The main occupational allergens are rubber additives, metals (chromium, nickel, cobalt), plastics (epoxy resins, acrylic), biocides and plants. Diagnosis is based on clinical examination, medical history and allergy testing. For a number of irritating or sensitizing agents, irritant or allergic dermatitis can be notified as occupational diseases. The two main prevention measures are reducing skin contact with irritants and complete avoidance of skin contact with offending allergens.

  17. Minimal Poems Written in 1979 Minimal Poems Written in 1979

    Directory of Open Access Journals (Sweden)

    Sandra Sirangelo Maggio

    2008-04-01

    Full Text Available The reading of M. van der Slice's Minimal Poems Written in 1979 (the work, actually, has no title reminded me of a book I have seen a long time ago. called Truth, which had not even a single word printed inside. In either case we have a sample of how often excentricities can prove efficient means of artistic creativity, in this new literary trend known as Minimalism. The reading of M. van der Slice's Minimal Poems Written in 1979 (the work, actually, has no title reminded me of a book I have seen a long time ago. called Truth, which had not even a single word printed inside. In either case we have a sample of how often excentricities can prove efficient means of artistic creativity, in this new literary trend known as Minimalism.

  18. HTSC-Josephson step contacts

    International Nuclear Information System (INIS)

    Herrmann, K.

    1994-03-01

    In this work the properties of josephson step contacts are investigated. After a short introduction into Josephson step contacts the structure, properties and the Josphson contacts of YBa 2 Cu 3 O 7-x high-T c superconductors is presented. The fabrication of HTSC step contacts and the microstructure is discussed. The electric properties of these contacts are measured together with the Josephson emission and the magnetic field dependence. The temperature dependence of the stationary transport properties is given. (WL)

  19. Contact dynamics math model

    Science.gov (United States)

    Glaese, John R.; Tobbe, Patrick A.

    1986-01-01

    The Space Station Mechanism Test Bed consists of a hydraulically driven, computer controlled six degree of freedom (DOF) motion system with which docking, berthing, and other mechanisms can be evaluated. Measured contact forces and moments are provided to the simulation host computer to enable representation of orbital contact dynamics. This report describes the development of a generalized math model which represents the relative motion between two rigid orbiting vehicles. The model allows motion in six DOF for each body, with no vehicle size limitation. The rotational and translational equations of motion are derived. The method used to transform the forces and moments from the sensor location to the vehicles' centers of mass is also explained. Two math models of docking mechanisms, a simple translational spring and the Remote Manipulator System end effector, are presented along with simulation results. The translational spring model is used in an attempt to verify the simulation with compensated hardware in the loop results.

  20. Contact allergy to lanolin

    DEFF Research Database (Denmark)

    Fransen, Marloes; Overgaard, Line E K; Johansen, Jeanne D

    2018-01-01

    BACKGROUND: Lanolin has been tested as lanolin alcohols (30% pet.) in baseline patch test series since 1969, and this has shown clinically relevant allergic contact dermatitis cases. OBJECTIVES: To investigate the temporal development of lanolin allergy (i.e. positive reaction to lanolin alcohols...... and/or Amerchol™ L-101), and the association between contact allergy to lanolin and patient characteristics from the MOAHLFA index. METHODS: A retrospective observational study of consecutively patch tested dermatitis patients (n = 9577) between 1 January 2004 and 31 December 2015 with lanolin...... alcohols 30% pet. and Amerchol™ L-101 50% pet. was performed. RESULTS: The prevalence of lanolin allergy increased from 0.45% in 2004 to 1.81% in 2015. In age-adjusted and sex-adjusted analyses, weak, significant associations were found between atopic dermatitis and lanolin and lanolin alcohols allergy...

  1. Minimal Flavour Violation and Beyond

    CERN Document Server

    Isidori, Gino

    2012-01-01

    We review the formulation of the Minimal Flavour Violation (MFV) hypothesis in the quark sector, as well as some "variations on a theme" based on smaller flavour symmetry groups and/or less minimal breaking terms. We also review how these hypotheses can be tested in B decays and by means of other flavour-physics observables. The phenomenological consequences of MFV are discussed both in general terms, employing a general effective theory approach, and in the specific context of the Minimal Supersymmetric extension of the SM.

  2. Minimizing waste in environmental restoration

    International Nuclear Information System (INIS)

    Thuot, J.R.; Moos, L.

    1996-01-01

    Environmental restoration, decontamination and decommissioning, and facility dismantlement projects are not typically known for their waste minimization and pollution prevention efforts. Typical projects are driven by schedules and milestones with little attention given to cost or waste minimization. Conventional wisdom in these projects is that the waste already exists and cannot be reduced or minimized; however, there are significant areas where waste and cost can be reduced by careful planning and execution. Waste reduction can occur in three ways: beneficial reuse or recycling, segregation of waste types, and reducing generation of secondary waste

  3. Minimizing waste in environmental restoration

    International Nuclear Information System (INIS)

    Moos, L.; Thuot, J.R.

    1996-01-01

    Environmental restoration, decontamination and decommissioning and facility dismantelment projects are not typically known for their waste minimization and pollution prevention efforts. Typical projects are driven by schedules and milestones with little attention given to cost or waste minimization. Conventional wisdom in these projects is that the waste already exists and cannot be reduced or minimized. In fact, however, there are three significant areas where waste and cost can be reduced. Waste reduction can occur in three ways: beneficial reuse or recycling; segregation of waste types; and reducing generation of secondary waste. This paper will discuss several examples of reuse, recycle, segregation, and secondary waste reduction at ANL restoration programs

  4. Contact stress sensor

    Science.gov (United States)

    Kotovsky, Jack [Oakland, CA

    2012-02-07

    A contact stress sensor includes one or more MEMS fabricated sensor elements, where each sensor element of includes a thin non-recessed portion, a recessed portion and a pressure sensitive element adjacent to the recessed portion. An electric circuit is connected to the pressure sensitive element. The circuit includes a thermal compensator and a pressure signal circuit element configured to provide a signal upon movement of the pressure sensitive element.

  5. Occupational protein contact dermatitis.

    Science.gov (United States)

    Barbaud, Annick; Poreaux, Claire; Penven, Emmanuelle; Waton, Julie

    2015-01-01

    Occupational contact dermatitis is generally caused by haptens but can also be induced by proteins causing mainly immunological contact urticaria (ICU); chronic hand eczema in the context of protein contact dermatitis (PCD). In a monocentric retrospective study, from our database, only 31 (0.41%) of patients with contact dermatitis had positive skin tests with proteins: 22 had occupational PCD, 3 had non-occupational PCD, 5 occupational ICU and 1 cook had a neutrophilic fixed food eruption (NFFE) due to fish. From these results and analysis of literature, the characteristics of PCD can be summarized as follows. It is a chronic eczematous dermatitis, possibly exacerbated by work, suggestive if associated with inflammatory perionyxix and immediate erythema with pruritis, to be investigated when the patient resumes work after a period of interruption. Prick tests with the suspected protein-containing material are essential, as patch tests have negative results. In case of multisensitisation revealed by prick tests, it is advisable to analyse IgE against recombinant allergens. A history of atopy, found in 56 to 68% of the patients, has to be checked for. Most of the cases are observed among food-handlers but PCD can also be due to non-edible plants, latex, hydrolysed proteins or animal proteins. Occupational exposure to proteins can thus lead to the development of ICU. Reflecting hypersensitivity to very low concentrations of allergens, investigating ICU therefore requires caution and prick tests should be performed with a diluted form of the causative protein-containing product. Causes are food, especially fruit peel, non-edible plants, cosmetic products, latex, animals.

  6. Fragrance contact allergy

    DEFF Research Database (Denmark)

    Johansen, Jeanne D

    2003-01-01

    . This gives a positive patch-test reaction in about 10% of tested patients with eczema, and the most recent estimates show that 1.7-4.1% of the general population are sensitized to ingredients of the fragrance mix. Fragrance allergy occurs predominantly in women with facial or hand eczema. These women...... development to identify contact allergy to new allergens, reflecting the continuous developments and trends in exposure....

  7. Pediatric contact dermatitis

    Directory of Open Access Journals (Sweden)

    Sharma Vinod

    2010-01-01

    Full Text Available Allergic contact dermatitis (ACD in children, until recently, was considered rare. ACD was considered as a disorder of the adult population and children were thought to be spared due to a lack of exposure to potential allergens and an immature immune system. Prevalence of ACD to even the most common allergens in children, like poison ivy and parthenium, is relatively rare as compared to adults. However, there is now growing evidence of contact sensitization of the pediatric population, and it begins right from early childhood, including 1-week-old neonates. Vaccinations, piercing, topical medicaments and cosmetics in younger patients are potential exposures for sensitization. Nickel is the most common sensitizer in almost all studies pertaining to pediatric contact dermatitis. Other common allergens reported are cobalt, fragrance mix, rubber, lanolin, thiomersol, neomycin, gold, mercapto mix, balsum of Peru and colophony. Different factors like age, sex, atopy, social and cultural practices, habit of parents and caregivers and geographic changes affect the patterns of ACD and their variable clinical presentation. Patch testing should be considered not only in children with lesions of a morphology suggestive of ACD, but in any child with dermatitis that is difficult to control.

  8. Projected Gauss-Seidel subspace minimization method for interactive rigid body dynamics

    DEFF Research Database (Denmark)

    Silcowitz-Hansen, Morten; Abel, Sarah Maria Niebe; Erleben, Kenny

    2010-01-01

    artifacts such as viscous or damped contact response. In this paper, we present a new approach to contact force determination. We formulate the contact force problem as a nonlinear complementarity problem, and discretize the problem to derive the Projected Gauss–Seidel method. We combine the Projected Gauss......–Seidel method with a subspace minimization method. Our new method shows improved qualities and superior convergence properties for specific configurations....

  9. Quark contact interactions at the LHC

    Science.gov (United States)

    Bazzocchi, F.; De Sanctis, U.; Fabbrichesi, M.; Tonero, A.

    2012-06-01

    Quark contact interactions are an important signal of new physics. We introduce a model in which the presence of a symmetry protects these new interactions from giving large corrections in flavor changing processes at low energies. This minimal model provides the basic set of operators which must be considered to contribute to the high-energy processes. To discuss their experimental signature in jet pairs produced in proton-proton collisions, we simplify the number of possible operators down to two. We show (for a representative integrated luminosity of 200pb-1 at s=7TeV) how the presence of two operators significantly modifies the bound on the characteristic energy scale of the contact interactions, which is obtained by keeping a single operator.

  10. Sludge minimization technologies - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Oedegaard, Hallvard

    2003-07-01

    The management of wastewater sludge from wastewater treatment plants represents one of the major challenges in wastewater treatment today. The cost of the sludge treatment amounts to more that the cost of the liquid in many cases. Therefore the focus on and interest in sludge minimization is steadily increasing. In the paper an overview is given for sludge minimization (sludge mass reduction) options. It is demonstrated that sludge minimization may be a result of reduced production of sludge and/or disintegration processes that may take place both in the wastewater treatment stage and in the sludge stage. Various sludge disintegration technologies for sludge minimization are discussed, including mechanical methods (focusing on stirred ball-mill, high-pressure homogenizer, ultrasonic disintegrator), chemical methods (focusing on the use of ozone), physical methods (focusing on thermal and thermal/chemical hydrolysis) and biological methods (focusing on enzymatic processes). (author)

  11. Wilson loops in minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS/CFT correspondence suggests that the Wilson loop of the large N gauge theory with N = 4 supersymmetry in 4 dimensions is described by a minimal surface in AdS 5 x S 5 . The authors examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which the authors call BPS loops, whose expectation values are free from ultra-violet divergence. They formulate the loop equation for such loops. To the extent that they have checked, the minimal surface in AdS 5 x S 5 gives a solution of the equation. The authors also discuss the zig-zag symmetry of the loop operator. In the N = 4 gauge theory, they expect the zig-zag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. They will show how this is realized for the minimal surface

  12. Classical strings and minimal surfaces

    International Nuclear Information System (INIS)

    Urbantke, H.

    1986-01-01

    Real Lorentzian forms of some complex or complexified Euclidean minimal surfaces are obtained as an application of H.A. Schwarz' solution to the initial value problem or a search for surfaces admitting a group of Poincare transformations. (Author)

  13. Minimal Gromov-Witten rings

    International Nuclear Information System (INIS)

    Przyjalkowski, V V

    2008-01-01

    We construct an abstract theory of Gromov-Witten invariants of genus 0 for quantum minimal Fano varieties (a minimal class of varieties which is natural from the quantum cohomological viewpoint). Namely, we consider the minimal Gromov-Witten ring: a commutative algebra whose generators and relations are of the form used in the Gromov-Witten theory of Fano varieties (of unspecified dimension). The Gromov-Witten theory of any quantum minimal variety is a homomorphism from this ring to C. We prove an abstract reconstruction theorem which says that this ring is isomorphic to the free commutative ring generated by 'prime two-pointed invariants'. We also find solutions of the differential equation of type DN for a Fano variety of dimension N in terms of the generating series of one-pointed Gromov-Witten invariants

  14. Wilson loops and minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS-CFT correspondence suggests that the Wilson loop of the large N gauge theory with N=4 supersymmetry in four dimensions is described by a minimal surface in AdS 5 xS 5 . We examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which we call BPS loops, whose expectation values are free from ultraviolet divergence. We formulate the loop equation for such loops. To the extent that we have checked, the minimal surface in AdS 5 xS 5 gives a solution of the equation. We also discuss the zigzag symmetry of the loop operator. In the N=4 gauge theory, we expect the zigzag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. We will show how this is realized for the minimal surface. (c) 1999 The American Physical Society

  15. [Sport injuries in full contact and semi-contact karate].

    Science.gov (United States)

    Greier, K; Riechelmann, H; Ziemska, J

    2014-03-01

    Karate enjoys great popularity both in professional and recreational sports and can be classified into full, half and low contact styles. The aim of this study was the analysis of sports injuries in Kyokushinkai (full contact) and traditional Karate (semi-contact). In a retrospective study design, 215 active amateur karateka (114 full contact, 101 semi-contact) were interviewed by means of a standardised questionnaire regarding typical sport injuries during the last 36 months. Injuries were categorised into severity grade I (not requiring medical treatment), grade II (single medical treatment), grade III (several outpatient medical treatments) and grade IV (requiring hospitalisation). In total, 217 injuries were reported in detail. 125 injuries (58%) occurred in full contact and 92 (42%) in semi-contact karate. The time related injury rate of full contact karateka was 1.9/1000 h compared to 1.3/1000 h of semi-contact karateka (p injuries were musculoskeletal contusions (33% full contact, 20% semi-contact), followed by articular sprains with 19% and 16%. The lower extremity was affected twice as often in full contact (40%) as in semi-contact (20%) karate. Training injuries were reported by 80% of the full contact and 77% of the semi-contact karateka. Most injuries, both in training and competition, occurred in kumite. 75% of the reported injuries of full contact and 70% of semi-contact karateka were classified as low grade (I or II). The high rate of injuries during training and kumite (sparring) points to specific prevention goals. The emphasis should be put on proprioceptive training and consistent warm-up. In the actual competition the referees play a vital role regarding prevention. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Mechanical Contact Experiments and Simulations

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Martins, P; Zhang, W.

    2011-01-01

    Mechanical contact is studied under dynamic development by means of a combined numerical and experimental investigation. The experiments are designed to allow dynamical development of non-planar contact areas with significant expansion in all three directions as the load is increased. Different....... The overall investigation serves for testing and validating the numerical implementation of the mechanical contact, which is one of the main contributions to a system intended for 3D simulation of resistance welding. Correct modelling of contact between parts to be welded, as well as contact with electrodes......, is crucial for satisfactory modelling of the resistance welding process. The resistance heating at the contact interfaces depends on both contact area and pressure, and as the contact areas develop dynamically, the presented tests are relevant for assessing the validity and accuracy of the mechanical contact...

  17. Minimal string theory is logarithmic

    International Nuclear Information System (INIS)

    Ishimoto, Yukitaka; Yamaguchi, Shun-ichi

    2005-01-01

    We study the simplest examples of minimal string theory whose worldsheet description is the unitary (p,q) minimal model coupled to two-dimensional gravity ( Liouville field theory). In the Liouville sector, we show that four-point correlation functions of 'tachyons' exhibit logarithmic singularities, and that the theory turns out to be logarithmic. The relation with Zamolodchikov's logarithmic degenerate fields is also discussed. Our result holds for generic values of (p,q)

  18. Annual Waste Minimization Summary Report

    International Nuclear Information System (INIS)

    Haworth, D.M.

    2011-01-01

    This report summarizes the waste minimization efforts undertaken by National Security TechnoIogies, LLC, for the U. S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO), during calendar year 2010. The NNSA/NSO Pollution Prevention Program establishes a process to reduce the volume and toxicity of waste generated by NNSA/NSO activities and ensures that proposed methods of treatment, storage, and/or disposal of waste minimize potential threats to human health and the environment.

  19. Minimal disease activity for rheumatoid arthritis: a preliminary definition

    NARCIS (Netherlands)

    Wells, George A.; Boers, Maarten; Shea, Beverley; Brooks, Peter M.; Simon, Lee S.; Strand, C. Vibeke; Aletaha, Daniel; Anderson, Jennifer J.; Bombardier, Claire; Dougados, Maxime; Emery, Paul; Felson, David T.; Fransen, Jaap; Furst, Dan E.; Hazes, Johanna M. W.; Johnson, Kent R.; Kirwan, John R.; Landewé, Robert B. M.; Lassere, Marissa N. D.; Michaud, Kaleb; Suarez-Almazor, Maria; Silman, Alan J.; Smolen, Josef S.; van der Heijde, Desiree M. F. M.; van Riel, Piet L. C. M.; Wolfe, Fred; Tugwell, Peter S.

    2005-01-01

    Agreement on response criteria in rheumatoid arthritis (RA) has allowed better standardization and interpretation of clinical trial reports. With recent advances in therapy, the proportion of patients achieving a satisfactory state of minimal disease activity (MDA) is becoming a more important

  20. Minimal disease activity for rheumatoid arthritis: a preliminary definition.

    NARCIS (Netherlands)

    Wells, G.A.; Boers, M.; Shea, B.; Brooks, P.M.; Simon, L.S.; Strand, C.V.; Aletaha, D.; Anderson, J.; Bombardier, C.; Dougados, M.; Emery, P.; Felson, D.T.; Fransen, J.; Furst, D.E.; Hazes, J.M.W.; Johnson, K.; Kirwan, J.; Landewe, R.B.; Lassere, M.N.; Michaud, K.; Suarez-Almazor, M.; Silman, A.J.; Smolen, J.S.; Heijde, D.M.F.M. van der; Riel, P.L.C.M. van; Wolfe, F.; Tugwell, P.S.

    2005-01-01

    Agreement on response criteria in rheumatoid arthritis (RA) has allowed better standardization and interpretation of clinical trial reports. With recent advances in therapy, the proportion of patients achieving a satisfactory state of minimal disease activity (MDA) is becoming a more important

  1. An elastic-plastic contact model for line contact structures

    Science.gov (United States)

    Zhu, Haibin; Zhao, Yingtao; He, Zhifeng; Zhang, Ruinan; Ma, Shaopeng

    2018-06-01

    Although numerical simulation tools are now very powerful, the development of analytical models is very important for the prediction of the mechanical behaviour of line contact structures for deeply understanding contact problems and engineering applications. For the line contact structures widely used in the engineering field, few analytical models are available for predicting the mechanical behaviour when the structures deform plastically, as the classic Hertz's theory would be invalid. Thus, the present study proposed an elastic-plastic model for line contact structures based on the understanding of the yield mechanism. A mathematical expression describing the global relationship between load history and contact width evolution of line contact structures was obtained. The proposed model was verified through an actual line contact test and a corresponding numerical simulation. The results confirmed that this model can be used to accurately predict the elastic-plastic mechanical behaviour of a line contact structure.

  2. Cognitive behavioural therapy for tinnitus.

    Science.gov (United States)

    Martinez Devesa, P; Waddell, A; Perera, R; Theodoulou, M

    2007-01-24

    Tinnitus is an auditory perception that can be described as the experience of sound, in the ear or in the head, in the absence of external acoustic stimulation (not usually audible to anyone else). At present no specific therapy for tinnitus is acknowledged to be satisfactory in all patients. Cognitive behavioural therapy (CBT) uses relaxation, cognitive restructuring of the thoughts and exposure to exacerbating situations in order to promote habituation and may benefit tinnitus patients, as may the treatment of associated psychological conditions. To assess whether cognitive behavioural therapy is effective in the management of patients suffering from tinnitus. Our search included the Cochrane ENT Group Trials Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 2, 2006), MEDLINE and EMBASE. The last search date was June 2006. Randomised controlled trials in which patients with unilateral or bilateral tinnitus as main symptom received cognitive behavioural treatment. One review author (PMD) assessed every report identified by the search strategy. The four review authors assessed the methodological quality, applied inclusion/exclusion criteria and extracted data. Six trials comprising 285 participants were included. 1. subjective tinnitus loudness. CBT compared to a waiting list control group: we found no significant difference (Standardised Mean Difference (SMD) 0.06 (95% CI -0.25 to 0.37)). CBT compared to another intervention (Yoga, Education, Minimal Contact - Education and Education): we found no significant difference (SMD 0.1 (95% CI -0.22 to 0.42)).2. a) Depression. CBT compared to a waiting list control group: we found no significant difference in either group (SMD 0.29 (95%CI -0.04 to 0.63)). CBT compared to another intervention (Yoga, Education and Minimal Contact - Education): we found no significant difference (SMD 0.01 (95% CI -0.43 to 0.45)). b) Quality of life: CBT compared to a waiting list control

  3. Contacting gases and liquids

    International Nuclear Information System (INIS)

    Robinson, L.F.; Cahalan, M.J.

    1980-01-01

    A process is described for contacting substantially immiscible phases to transfer material from one phase to another, which comprises passing the phases through a contactor, while causing portions of at least one phase to be repeatedly passed through at least one other phase. One phase in the contactor is gaseous, and another liquid. A further phase can be liquid or solid The process may be used for extracting impurities from china clay, or extracting uranium values from ore with oxygen gas acting to oxidise the uranium. (author)

  4. Precision contact level gauge

    International Nuclear Information System (INIS)

    Krejci, M.; Pilat, M.; Stulik, P.

    1977-01-01

    Equipment was developed measuring the heavy water level in the TR-0 reactor core within an accuracy of several hundredths of a millimeter in a range of around 3.5 m and at a temperature of up to 90 degC. The equipment uses a vibrating needle contact as a high sensitivity level gauge and a servomechanical system with a motion screw carrying the gauge for monitoring and measuring the level in the desired range. The advantage of the unique level gauge consists in that that the transducer converts the measured level position to an electric signal, ie., pulse width, with high sensitivity and without hysteresis. (Kr)

  5. Thermal contact conductance

    CERN Document Server

    Madhusudana, Chakravarti V

    2013-01-01

    The work covers both theoretical and practical aspects of thermal contact conductance. The theoretical discussion focuses on heat transfer through spots, joints, and surfaces, as well as the role of interstitial materials (both planned and inadvertent). The practical discussion includes formulae and data that can be used in designing heat-transfer equipment for a variety of joints, including special geometries and configurations. All of the material has been updated to reflect the latest advances in the field.

  6. Contact ionization ion source

    International Nuclear Information System (INIS)

    Hashmi, N.; Van Der Houven Van Oordt, A.J.

    1975-01-01

    An ion source in which an apertured or foraminous electrode having a multiplicity of openings is spaced from one or more active surfaces of an ionisation electrode, the active surfaces comprising a material capable of ionising by contact ionization a substance to be ionized supplied during operation to the active surface or surfaces comprises means for producing during operation a magnetic field which enables a stable plasma to be formed in the space between the active surface or surfaces and the apertured electrode, the field strength of the magnetic field being preferably in the range between 2 and 8 kilogauss. (U.S.)

  7. Minimal but non-minimal inflation and electroweak symmetry breaking

    Energy Technology Data Exchange (ETDEWEB)

    Marzola, Luca [National Institute of Chemical Physics and Biophysics,Rävala 10, 10143 Tallinn (Estonia); Institute of Physics, University of Tartu,Ravila 14c, 50411 Tartu (Estonia); Racioppi, Antonio [National Institute of Chemical Physics and Biophysics,Rävala 10, 10143 Tallinn (Estonia)

    2016-10-07

    We consider the most minimal scale invariant extension of the standard model that allows for successful radiative electroweak symmetry breaking and inflation. The framework involves an extra scalar singlet, that plays the rôle of the inflaton, and is compatibile with current experimental bounds owing to the non-minimal coupling of the latter to gravity. This inflationary scenario predicts a very low tensor-to-scalar ratio r≈10{sup −3}, typical of Higgs-inflation models, but in contrast yields a scalar spectral index n{sub s}≃0.97 which departs from the Starobinsky limit. We briefly discuss the collider phenomenology of the framework.

  8. Optimal contact definition for reconstruction of Contact Maps

    Directory of Open Access Journals (Sweden)

    Stehr Henning

    2010-05-01

    Full Text Available Abstract Background Contact maps have been extensively used as a simplified representation of protein structures. They capture most important features of a protein's fold, being preferred by a number of researchers for the description and study of protein structures. Inspired by the model's simplicity many groups have dedicated a considerable amount of effort towards contact prediction as a proxy for protein structure prediction. However a contact map's biological interest is subject to the availability of reliable methods for the 3-dimensional reconstruction of the structure. Results We use an implementation of the well-known distance geometry protocol to build realistic protein 3-dimensional models from contact maps, performing an extensive exploration of many of the parameters involved in the reconstruction process. We try to address the questions: a to what accuracy does a contact map represent its corresponding 3D structure, b what is the best contact map representation with regard to reconstructability and c what is the effect of partial or inaccurate contact information on the 3D structure recovery. Our results suggest that contact maps derived from the application of a distance cutoff of 9 to 11Å around the Cβ atoms constitute the most accurate representation of the 3D structure. The reconstruction process does not provide a single solution to the problem but rather an ensemble of conformations that are within 2Å RMSD of the crystal structure and with lower values for the pairwise average ensemble RMSD. Interestingly it is still possible to recover a structure with partial contact information, although wrong contacts can lead to dramatic loss in reconstruction fidelity. Conclusions Thus contact maps represent a valid approximation to the structures with an accuracy comparable to that of experimental methods. The optimal contact definitions constitute key guidelines for methods based on contact maps such as structure prediction through

  9. Allergic contact dermatitis from octylisothiazolinone

    DEFF Research Database (Denmark)

    Mose, Anja Pahlow; Frost, Simon; Ohlund, Ulf

    2013-01-01

    Octylisothiazolinone is a biocide that has been reported as a moderate, but rare contact allergen.......Octylisothiazolinone is a biocide that has been reported as a moderate, but rare contact allergen....

  10. Microneedle physical contact as a therapeutic for abnormal scars

    OpenAIRE

    Yeo, David C.; Balmayor, Elizabeth R.; Schantz, Jan-Thorsten; Xu, Chenjie

    2017-01-01

    Background Abnormal (keloid and hypertrophic) scars are a significant affliction with no satisfactory single modality therapy to-date. Available options are often ineffective, painful, potentially hazardous, and require healthcare personnel involvement. Herein a self-administered microneedle device based on drug-free physical contact for inhibiting abnormal scars is reported. Its therapeutic activity through microneedle contact eliminates hazards associated with toxic anti-scarring drugs whil...

  11. Minimal modification to tribimaximal mixing

    International Nuclear Information System (INIS)

    He Xiaogang; Zee, A.

    2011-01-01

    We explore some ways of minimally modifying the neutrino mixing matrix from tribimaximal, characterized by introducing at most one mixing angle and a CP violating phase thus extending our earlier work. One minimal modification, motivated to some extent by group theoretic considerations, is a simple case with the elements V α2 of the second column in the mixing matrix equal to 1/√(3). Modifications by keeping one of the columns or one of the rows unchanged from tribimaximal mixing all belong to the class of minimal modification. Some of the cases have interesting experimentally testable consequences. In particular, the T2K and MINOS collaborations have recently reported indications of a nonzero θ 13 . For the cases we consider, the new data sharply constrain the CP violating phase angle δ, with δ close to 0 (in some cases) and π disfavored.

  12. Minimal Marking: A Success Story

    Directory of Open Access Journals (Sweden)

    Anne McNeilly

    2014-11-01

    Full Text Available The minimal-marking project conducted in Ryerson’s School of Journalism throughout 2012 and early 2013 resulted in significantly higher grammar scores in two first-year classes of minimally marked university students when compared to two traditionally marked classes. The “minimal-marking” concept (Haswell, 1983, which requires dramatically more student engagement, resulted in more successful learning outcomes for surface-level knowledge acquisition than the more traditional approach of “teacher-corrects-all.” Results suggest it would be effective, not just for grammar, punctuation, and word usage, the objective here, but for any material that requires rote-memory learning, such as the Associated Press or Canadian Press style rules used by news publications across North America.

  13. Non-minimal inflation revisited

    International Nuclear Information System (INIS)

    Nozari, Kourosh; Shafizadeh, Somayeh

    2010-01-01

    We reconsider an inflationary model that inflaton field is non-minimally coupled to gravity. We study the parameter space of the model up to the second (and in some cases third) order of the slow-roll parameters. We calculate inflation parameters in both Jordan and Einstein frames, and the results are compared in these two frames and also with observations. Using the recent observational data from combined WMAP5+SDSS+SNIa datasets, we study constraints imposed on our model parameters, especially the non-minimal coupling ξ.

  14. Minimal Flavor Constraints for Technicolor

    DEFF Research Database (Denmark)

    Sakuma, Hidenori; Sannino, Francesco

    2010-01-01

    We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self-coupling and mas......We analyze the constraints on the the vacuum polarization of the standard model gauge bosons from a minimal set of flavor observables valid for a general class of models of dynamical electroweak symmetry breaking. We will show that the constraints have a strong impact on the self...

  15. Harm minimization among teenage drinkers

    DEFF Research Database (Denmark)

    Jørgensen, Morten Hulvej; Curtis, Tine; Christensen, Pia Haudrup

    2007-01-01

    AIM: To examine strategies of harm minimization employed by teenage drinkers. DESIGN, SETTING AND PARTICIPANTS: Two periods of ethnographic fieldwork were conducted in a rural Danish community of approximately 2000 inhabitants. The fieldwork included 50 days of participant observation among 13....... In regulating the social context of drinking they relied on their personal experiences more than on formalized knowledge about alcohol and harm, which they had learned from prevention campaigns and educational programmes. CONCLUSIONS: In this study we found that teenagers may help each other to minimize alcohol...

  16. Impact of the shape of geological contact on mining losses in the process of near-contact zone development

    Directory of Open Access Journals (Sweden)

    Г. С. Курчин

    2017-03-01

    Full Text Available In Russia development of mineral resources is carried out on a truly grand scale, and mining industry is in its essence a basic sector, supporting and facilitating the development of national economy. It predetermines the need of safe and responsible attitude towards riches of our subsoil – mineral resources. With this in mind, one of the key requirements to extraction technologies is minimization of mining losses and ore dilution.The biggest ore losses in the mining block take place in the process of development of contact areas between the ore body and surrounding rocks, due to differences between development pattern and surface of geological contact. Complexity of the contact between ore and surrounding rocks is traditionally characterized by so called «stochastic contact zone». Technological difficulty of extracting ore from the ore – wallrock contact is determined by volatility of geometric parameters in «stochastic contact zone» in the plane of geological contact.Current paper focuses on the issues of standard-setting for mining losses and ore dilution in the process of near-contact zone development. A method is suggested to estimate standard values of losses and ore dilution in stochastic zones. Authors have developed an algorithm of defining the shape of the contact. In the stochastic zone the contact can have a rectangular, sinusoidal, serrate and straight-line shapes. Research has established a relation between the contact shape and amounts of mining losses and ore dilution, formulas to calculate standard values are presented. Using suggested method, standard values for contact ore losses can be obtained in a quicker and more reliable way.

  17. Fragrance contact allergy

    DEFF Research Database (Denmark)

    Johansen, Jeanne D

    2003-01-01

    in the same products. This means that it is difficult to avoid exposure, as products labelled as 'fragrance free' have also been shown to contain fragrance ingredients, either because of the use of fragrance ingredients as preservatives or masking perfumes, or the use of botanicals. About 2500 different...... fragrance ingredients are currently used in the composition of perfumes and at least 100 of these are known contact allergens. Therefore, it is advisable to supplement standard patch testing with the patient's own stay-on cosmetic products, as well as the fragrance chemical hydroxyisohexyl-3-cyclohexane...... carboxaldehyde, which on its own gives responses in 1-3% of tested patients. The focus in recent years on the ingredients of the fragrance mix will probably result in the fragrance industry changing the composition of perfumes, and thus make the current diagnostic test less useful. New diagnostic tests are under...

  18. Cosmetic Contact Allergens

    Directory of Open Access Journals (Sweden)

    An Goossens

    2016-02-01

    Full Text Available This article presents trends in the frequency of cosmetics as causal factors of allergic contact dermatitis during a 26-year period in 14,911 patients patch-tested between 1990 and 2014, and discusses the cosmetic allergens identified during the last six years (2010–2015 in 603 patients out of 3105 tested. The data were retrieved from, and evaluated with, a patient database developed in-house. The results show the increasing importance of cosmetic allergies, up to 25% of the patients tested during the last five-year period. As expected, fragrance materials, preservatives, and hair dyes were the most frequent culprits, but a great variety of other allergenic ingredients were involved as well. This underlines the need of additional and extensive patch testing with the patient’s products used and their ingredients.

  19. Hair dye contact allergy

    DEFF Research Database (Denmark)

    Søsted, Heidi; Rastogi, Suresh Chandra; Andersen, Klaus Ejner

    2004-01-01

    Colouring of hair can cause severe allergic contact dermatitis. The most frequently reported hair dye allergens are p-phenylenediamine (PPD) and toluene-2,5-diamine, which are included in, respectively, the patch test standard series and the hairdressers series. The aim of the present study...... was to identify dye precursors and couplers in hair dyeing products causing clinical hair dye dermatitis and to compare the data with the contents of these compounds in a randomly selected set of similar products. The patient material comprised 9 cases of characteristic clinical allergic hair dye reaction, where...... exposure history and patch testing had identified a specific hair dye product as the cause of the reaction. The 9 products used by the patients were subjected to chemical analysis. 8 hair dye products contained toluene-2,5-diamine (0.18 to 0.98%). PPD (0.27%) was found in 1 product, and m-aminophenol (0...

  20. Mechanoluminescent Contact Type Sensor

    Directory of Open Access Journals (Sweden)

    A. K. Yefremov

    2017-01-01

    Full Text Available Mechanoluminescent sensing elements convert mechanical stress into optical radiation. Advantages of such sensors are the ability to generate an optical signal, solid-state, simple structure, and resistance to electromagnetic interference. Mechanoluminescent sensor implementations can possess the concentrated and distributed sensitivity, thereby allowing us to detect the field of mechanical stresses distributed across the area and in volume. Most modern semiconductor photo-detectors can detect mechanoluminescent radiation, so there are no difficulties to provide its detection when designing the mechanoluminescent sensing devices. Mechanoluminescent substances have especial sensitivity to shock loads, and this effect can be used to create a fuse the structure of which includes a target contact type sensor with a photosensitive actuator. The paper briefly describes the theoretical basics of mechanoluminiscence: a light signal emerges from the interaction of crystalline phosphor luminescence centers with electrically charged dislocations, moving due to the deformation of the crystal. A mathematical model of the mechanoluminescent conversion is represented as a functional interaction between parameters of the mechanical shock excitation and the sensor light emission. Examples of computing the optical mechanoluminescent output signal depending on the duration and peak level of impulse load are given. It is shown that the luminous flux, generated by mechanoluminescent sensing element when there is an ammunition-target collision causes the current emerging in photo-detector (photodiode that is sufficient for a typical actuator of the fuse train to operate. The potential possibility to create a contact target type sensor based on the light-sensitive mechanoluminescent sensor was proved by the calculation and simulation results.

  1. Cost-minimization analysis of antimicrobial therapy in a tertiary ...

    African Journals Online (AJOL)

    The mean cost per defined daily dosage (DDD) of generic and branded for each antibacterial was computed. These were compared using Student's t-test. The outcome measure was potential eradication of bacterial in question by the respective antibacterial drug. The analyses showed that the use of expensive branded ...

  2. Current minimally invasive and endourological therapy in pediatric nephrolithiasis

    Directory of Open Access Journals (Sweden)

    N. Khater

    2014-06-01

    Conclusion: ESWL alone, for a large stone, or in a lower pole in uninephric children is not the standard of care. PCNL offer an appropriate and therapeutic modality in specific situation i.e. larger stones, the lower pole stones with stone free rate approaching 80%. Nevertheless, flexible ureteroscopy with the newest high definition cameras has a promising potential in reaching a 100% stone-free rate in the near future.

  3. Cytokine and gene therapy of minimal residual tumour disease

    Czech Academy of Sciences Publication Activity Database

    Bubeník, Jan; Šímová, Jana; Mikyšková, Romana; Mendoza, Luis; Jandlová, Táňa

    1999-01-01

    Roč. 4, Suppl. 1 (1999), s. S10 ISSN 1107-3756. [World Congress on Advances in Oncology /4./, International Symposium on Molecular Medicine /2./. 07.10.1999-09.10.1999, Vouliagmeni, Atény] Subject RIV: EC - Immunology

  4. Current minimally invasive and endourological therapy in pediatric ...

    African Journals Online (AJOL)

    N. Khater

    Introduction: Children with complex urinary tract stones present a treatment challenge. There is ..... medical cause if it exists, like treatment of infections, to avoid recur- rence of .... outcome for stones of 1–2cm depends on the predictive factors.

  5. Contact lens wear and dry eyes: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Markoulli M

    2017-02-01

    Full Text Available Maria Markoulli, Sailesh Kolanu School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia Abstract: The number of contact lens wearers worldwide has remained relatively stable over the past decade, despite the investment that has gone into contact lens technology. This is largely because 10%–50% of wearers dropout of contact lens wear within 3 years of commencement; the most common reason cited being contact lens discomfort (CLD. Of the symptoms reported, sensation of dry eye is the most common. Given the outcome of reduced wearing time, increased chair time, and ultimate contact lens discontinuation, the challenge is to identify the warning signs of CLD early on. Clinically detectable changes such as conjunctival staining, conjunctival indentation, conjunctival epithelial flap formation, lid wiper epitheliopathy, Demodex blepharitis, and meibomian gland dysfunction have been linked to CLD, highlighting the need to perform regular aftercare visits to identify these changes. At a cellular level, conjunctival metaplasia and reduced goblet cell density have been linked to CLD, leading to a downstream effect on the tear film breakup time of contact lens wearers. These factors suggest a strong link between CLD and friction, raising the need to target this as a means of minimizing CLD. The purpose of this review is to identify the clinical signs that relate to CLD as a means of earlier detection and management in order to combat contact lens dropout. Keywords: contact lens discomfort, dry eye disease, lid wiper epitheliopathy, tear film biomarkers, meibomian gland dysfunction

  6. Reducing contact resistance in graphene devices through contact area patterning.

    Science.gov (United States)

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  7. Contact angle and local wetting at contact line.

    Science.gov (United States)

    Li, Ri; Shan, Yanguang

    2012-11-06

    This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.

  8. Equilibrium contact angle or the most-stable contact angle?

    Science.gov (United States)

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  9. Contact and Non-contact Measurements of Grinding Pins

    Directory of Open Access Journals (Sweden)

    Magdziak Marek

    2015-01-01

    Full Text Available The paper presents the results of contact and non-contact measurements of external profiles of selected grinding pins. The measurements were conducted in order to choose the appropriate measuring technique in the case of the considered measurement task. In the case of contact measurements the coordinate measuring machine ACCURA II was applied. The used coordinate measuring machine was equipped with the contact scanning probe VAST XT and the Calypso inspection software. Contact coordinate measurements were performed by using of different measurement strategies. The applied strategies included different scanning velocities and distances between measured points. Non-contact measurements were conducted by means of the tool presetter produced by the Mahr company. On the basis of gained results the guidelines concerning measurements of grinding pins were formulated. The measurements of analyzed grinding pins performed by means of the non-contact measuring system are characterized by higher reproducibility than the contact measurements. The low reproducibility of contact measurements may be connected with the inaccuracy of the selected coordinate measuring machine and the measuring probe, the measurement parameters and environmental conditions in the laboratory where the coordinate measuring machine is located. Moreover, the paper presents the possible application of results of conducted investigations. The results of non-contact measurements can be used in the simulation studies of grinding processes. The simulations may reduce the costs of machining processes.

  10. Isoperimetric inequalities for minimal graphs

    International Nuclear Information System (INIS)

    Pacelli Bessa, G.; Montenegro, J.F.

    2007-09-01

    Based on Markvorsen and Palmer's work on mean time exit and isoperimetric inequalities we establish slightly better isoperimetric inequalities and mean time exit estimates for minimal graphs in N x R. We also prove isoperimetric inequalities for submanifolds of Hadamard spaces with tamed second fundamental form. (author)

  11. A Defense of Semantic Minimalism

    Science.gov (United States)

    Kim, Su

    2012-01-01

    Semantic Minimalism is a position about the semantic content of declarative sentences, i.e., the content that is determined entirely by syntax. It is defined by the following two points: "Point 1": The semantic content is a complete/truth-conditional proposition. "Point 2": The semantic content is useful to a theory of…

  12. Torsional Rigidity of Minimal Submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, Vicente

    2006-01-01

    We prove explicit upper bounds for the torsional rigidity of extrinsic domains of minimal submanifolds $P^m$ in ambient Riemannian manifolds $N^n$ with a pole $p$. The upper bounds are given in terms of the torsional rigidities of corresponding Schwarz symmetrizations of the domains in warped...

  13. The debate on minimal deterrence

    International Nuclear Information System (INIS)

    Arbatov, A.; Karp, R.C.; Toth, T.

    1993-01-01

    Revitalization of debates on minimal nuclear deterrence at the present time is induced by the end of the Cold War and a number of unilateral and bilateral actions by the great powers to curtail nuclear arms race and reduce nuclear weapons arsenals

  14. LLNL Waste Minimization Program Plan

    International Nuclear Information System (INIS)

    1990-01-01

    This document is the February 14, 1990 version of the LLNL Waste Minimization Program Plan (WMPP). The Waste Minimization Policy field has undergone continuous changes since its formal inception in the 1984 HSWA legislation. The first LLNL WMPP, Revision A, is dated March 1985. A series of informal revision were made on approximately a semi-annual basis. This Revision 2 is the third formal issuance of the WMPP document. EPA has issued a proposed new policy statement on source reduction and recycling. This policy reflects a preventative strategy to reduce or eliminate the generation of environmentally-harmful pollutants which may be released to the air, land surface, water, or ground water. In accordance with this new policy new guidance to hazardous waste generators on the elements of a Waste Minimization Program was issued. In response to these policies, DOE has revised and issued implementation guidance for DOE Order 5400.1, Waste Minimization Plan and Waste Reduction reporting of DOE Hazardous, Radioactive, and Radioactive Mixed Wastes, final draft January 1990. This WMPP is formatted to meet the current DOE guidance outlines. The current WMPP will be revised to reflect all of these proposed changes when guidelines are established. Updates, changes and revisions to the overall LLNL WMPP will be made as appropriate to reflect ever-changing regulatory requirements. 3 figs., 4 tabs

  15. Minimizing TLD-DRD differences

    International Nuclear Information System (INIS)

    Riley, D.L.; McCoy, R.A.; Connell, W.D.

    1987-01-01

    When substantial differences exist in exposures recorded by TLD's and DRD's, it is often necessary to perform an exposure investigation to reconcile the difference. In working with several operating plants, the authors have observed a number of causes for these differences. This paper outlines these observations and discusses procedures that can be used to minimize them

  16. Acquiring minimally invasive surgical skills

    NARCIS (Netherlands)

    Hiemstra, Ellen

    2012-01-01

    Many topics in surgical skills education have been implemented without a solid scientific basis. For that reason we have tried to find this scientific basis. We have focused on training and evaluation of minimally invasive surgical skills in a training setting and in practice in the operating room.

  17. Is Bicarbonate Therapy Useful?

    Science.gov (United States)

    Hopper, Kate

    2017-03-01

    Despite concerns about the negative effects of metabolic acidosis, there is minimal evidence that sodium bicarbonate administration is an effective treatment. In addition, sodium bicarbonate therapy is associated with many adverse effects, including paradoxic intracellular acidosis, hypokalemia, hypocalcemia, hypernatremia, and hyperosmolality. Definitive recommendations regarding bicarbonate therapy are challenging as there is little high-quality evidence available. In most clinical scenarios of metabolic acidosis, treatment efforts should focus on resolution of the underlying cause, and sodium bicarbonate therapy should be used with caution, if at all. An exception to this is kidney disease, wherein sodium bicarbonate therapy may have a valuable role. Published by Elsevier Inc.

  18. Hazardous waste minimization tracking system

    International Nuclear Information System (INIS)

    Railan, R.

    1994-01-01

    Under RCRA section 3002 9(b) and 3005f(h), hazardous waste generators and owners/operators of treatment, storage, and disposal facilities (TSDFs) are required to certify that they have a program in place to reduce the volume or quantity and toxicity of hazardous waste to the degree determined to be economically practicable. In many cases, there are environmental, as well as, economic benefits, for agencies that pursue pollution prevention options. Several state governments have already enacted waste minimization legislation (e.g., Massachusetts Toxic Use Reduction Act of 1989, and Oregon Toxic Use Reduction Act and Hazardous Waste Reduction Act, July 2, 1989). About twenty six other states have established legislation that will mandate some type of waste minimization program and/or facility planning. The need to address the HAZMIN (Hazardous Waste Minimization) Program at government agencies and private industries has prompted us to identify the importance of managing The HAZMIN Program, and tracking various aspects of the program, as well as the progress made in this area. The open-quotes WASTEclose quotes is a tracking system, which can be used and modified in maintaining the information related to Hazardous Waste Minimization Program, in a manageable fashion. This program maintains, modifies, and retrieves information related to hazardous waste minimization and recycling, and provides automated report generating capabilities. It has a built-in menu, which can be printed either in part or in full. There are instructions on preparing The Annual Waste Report, and The Annual Recycling Report. The program is very user friendly. This program is available in 3.5 inch or 5 1/4 inch floppy disks. A computer with 640K memory is required

  19. Contextualizing Intergroup Contact: Do Political Party Cues Enhance Contact Effects?

    DEFF Research Database (Denmark)

    Sønderskov, Kim Mannemar; Thomsen, Jens Peter Frølund

    2015-01-01

    This article examines intergroup contact effects in different political contexts. We expand on previous efforts of social psychologists by incorporating the messages of political parties as a contextual trigger of group membership awareness in contact situations. We argue that the focus among...... political parties on us-them categorizations heightens the awareness of group memberships. This focus in turn enhances the positive intergroup contact effect by stimulating majority members to perceive contacted persons as prototypical outgroup members. A multilevel analysis of 22 countries and almost 37......,000 individuals confirms that the ability of intergroup contact to reduce antiforeigner sentiment increases when political parties focus intensively on immigration issues and cultural differences. Specifically, both workplace contact and interethnic friendship become more effective in reducing antiforeigner...

  20. Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness.

    Science.gov (United States)

    Abduo, Jaafar

    2017-01-01

    This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.

  1. Quaternionic contact Einstein structures and the quaternionic contact Yamabe problem

    CERN Document Server

    Ivanov, Stefan; Vassilev, Dimiter

    2014-01-01

    A partial solution of the quaternionic contact Yamabe problem on the quaternionic sphere is given. It is shown that the torsion of the Biquard connection vanishes exactly when the trace-free part of the horizontal Ricci tensor of the Biquard connection is zero and this occurs precisely on 3-Sasakian manifolds. All conformal transformations sending the standard flat torsion-free quaternionic contact structure on the quaternionic Heisenberg group to a quaternionic contact structure with vanishing torsion of the Biquard connection are explicitly described. A "3-Hamiltonian form" of infinitesimal conformal automorphisms of quaternionic contact structures is presented.

  2. Stability analysis of rough surfaces in adhesive normal contact

    Science.gov (United States)

    Rey, Valentine; Bleyer, Jeremy

    2018-03-01

    This paper deals with adhesive frictionless normal contact between one elastic flat solid and one stiff solid with rough surface. After computation of the equilibrium solution of the energy minimization principle and respecting the contact constraints, we aim at studying the stability of this equilibrium solution. This study of stability implies solving an eigenvalue problem with inequality constraints. To achieve this goal, we propose a proximal algorithm which enables qualifying the solution as stable or unstable and that gives the instability modes. This method has a low computational cost since no linear system inversion is required and is also suitable for parallel implementation. Illustrations are given for the Hertzian contact and for rough contact.

  3. [Contact glass tonometer].

    Science.gov (United States)

    Dekker, P W; Kanngiesser, H; Robert, Y C

    1996-05-01

    This paper presents a tonometer built into a contactlens, which allows to measure the eye-pressure and to perform ophthalmoscopy at the same time. Artificially induced changes of the eye-pressure and their influence on the visible fundus can now be checked simultaneously. The contactlens-tonometer (CGT) also is able to record continuously the pulse-curve, which can indicate any circulatory problem. So, the device is expected to give us additional diagnostic criteria of early glaucoma. Each ophthalmologyst in the field will be able to perform with this device a oculodynamometry in an easy way. By this it is possible to estimate the pressure-tolerance of the optic disk from glaucoma-patients. There have been taken some measurements on enucleated human eyes, comparing our device with a Statham-transducer in the vitreous. We found a good correlation. In a second step, we made measurements (65) on healthy volunteers, comparing the device with Perkins-Tonometry. We found a correlation (R = 0.58). The error of the measurements was about +/- 3 mm Hg. Considering both, the deviation of the Perkins-Tonometer with which our results were compared, and the fact of a good correlation (R = 0.999) in the study with the enucleated human eyes, we found that the contact-lens-tonometer measures the intraocular pressure exactly. In future studies, we want to analyze the dynamic component of the measurements.

  4. Contact sport and osteoarthritis.

    LENUS (Irish Health Repository)

    Molloy, Michael G

    2011-04-01

    Osteoarthritis (OA) is the most common joint disease in the world and the single largest cause of disability for those over 18 years. It affects more than twice as many people as does cardiac disease, and increases in incidence and prevalence with age. Animal and human studies have shown no evidence of increased risk of hip or knee OA with moderate exercise and in the absence of traumatic injury, sporting activity has a protective effect. One age-matched case control study found recreational runners who ran 12-14 miles per week for up to 40 years had no increase in radiological or symptomatic hip or knee OA. However, higher rates of hip OA occur in contact sports than in age-matched controls, with the highest rate in professional players. Soccer players with torn anterior cruciate ligaments (ACL) are more likely to develop knee OA than those with intact ACL. Early ACL repair reduces the risk of knee OA, but does not prevent it. Established injury prevention programmes have been refined to prevent injuries such as ACL rupture.

  5. Minimalism and the Pragmatic Frame

    Directory of Open Access Journals (Sweden)

    Ana Falcato

    2016-02-01

    Full Text Available In the debate between literalism and contextualism in semantics, Kent Bach’s project is often taken to stand on the latter side of the divide. In this paper I argue this is a misleading assumption and justify it by contrasting Bach’s assessment of the theoretical eliminability of minimal propositions arguably expressed by well-formed sentences with standard minimalist views, and by further contrasting his account of the division of interpretative processes ascribable to the semantics and pragmatics of a language with a parallel analysis carried out by the most radical opponent to semantic minimalism, i.e., by occasionalism. If my analysis proves right, the sum of its conclusions amounts to a refusal of Bach’s main dichotomies.

  6. Principle of minimal work fluctuations.

    Science.gov (United States)

    Xiao, Gaoyang; Gong, Jiangbin

    2015-08-01

    Understanding and manipulating work fluctuations in microscale and nanoscale systems are of both fundamental and practical interest. For example, in considering the Jarzynski equality 〈e-βW〉=e-βΔF, a change in the fluctuations of e-βW may impact how rapidly the statistical average of e-βW converges towards the theoretical value e-βΔF, where W is the work, β is the inverse temperature, and ΔF is the free energy difference between two equilibrium states. Motivated by our previous study aiming at the suppression of work fluctuations, here we obtain a principle of minimal work fluctuations. In brief, adiabatic processes as treated in quantum and classical adiabatic theorems yield the minimal fluctuations in e-βW. In the quantum domain, if a system initially prepared at thermal equilibrium is subjected to a work protocol but isolated from a bath during the time evolution, then a quantum adiabatic process without energy level crossing (or an assisted adiabatic process reaching the same final states as in a conventional adiabatic process) yields the minimal fluctuations in e-βW, where W is the quantum work defined by two energy measurements at the beginning and at the end of the process. In the classical domain where the classical work protocol is realizable by an adiabatic process, then the classical adiabatic process also yields the minimal fluctuations in e-βW. Numerical experiments based on a Landau-Zener process confirm our theory in the quantum domain, and our theory in the classical domain explains our previous numerical findings regarding the suppression of classical work fluctuations [G. Y. Xiao and J. B. Gong, Phys. Rev. E 90, 052132 (2014)].

  7. Optimizing Processes to Minimize Risk

    Science.gov (United States)

    Loyd, David

    2017-01-01

    NASA, like the other hazardous industries, has suffered very catastrophic losses. Human error will likely never be completely eliminated as a factor in our failures. When you can't eliminate risk, focus on mitigating the worst consequences and recovering operations. Bolstering processes to emphasize the role of integration and problem solving is key to success. Building an effective Safety Culture bolsters skill-based performance that minimizes risk and encourages successful engagement.

  8. Minimal Length, Measurability and Gravity

    Directory of Open Access Journals (Sweden)

    Alexander Shalyt-Margolin

    2016-03-01

    Full Text Available The present work is a continuation of the previous papers written by the author on the subject. In terms of the measurability (or measurable quantities notion introduced in a minimal length theory, first the consideration is given to a quantum theory in the momentum representation. The same terms are used to consider the Markov gravity model that here illustrates the general approach to studies of gravity in terms of measurable quantities.

  9. [Minimally invasive coronary artery surgery].

    Science.gov (United States)

    Zalaquett, R; Howard, M; Irarrázaval, M J; Morán, S; Maturana, G; Becker, P; Medel, J; Sacco, C; Lema, G; Canessa, R; Cruz, F

    1999-01-01

    There is a growing interest to perform a left internal mammary artery (LIMA) graft to the left anterior descending coronary artery (LAD) on a beating heart through a minimally invasive access to the chest cavity. To report the experience with minimally invasive coronary artery surgery. Analysis of 11 patients aged 48 to 79 years old with single vessel disease that, between 1996 and 1997, had a LIMA graft to the LAD performed through a minimally invasive left anterior mediastinotomy, without cardiopulmonary bypass. A 6 to 10 cm left parasternal incision was done. The LIMA to the LAD anastomosis was done after pharmacological heart rate and blood pressure control and a period of ischemic pre conditioning. Graft patency was confirmed intraoperatively by standard Doppler techniques. Patients were followed for a mean of 11.6 months (7-15 months). All patients were extubated in the operating room and transferred out of the intensive care unit on the next morning. Seven patients were discharged on the third postoperative day. Duplex scanning confirmed graft patency in all patients before discharge; in two patients, it was confirmed additionally by arteriography. There was no hospital mortality, no perioperative myocardial infarction and no bleeding problems. After follow up, ten patients were free of angina, in functional class I and pleased with the surgical and cosmetic results. One patient developed atypical angina on the seventh postoperative month and a selective arteriography confirmed stenosis of the anastomosis. A successful angioplasty of the original LAD lesion was carried out. A minimally invasive left anterior mediastinotomy is a good surgical access to perform a successful LIMA to LAD graft without cardiopulmonary bypass, allowing a shorter hospital stay and earlier postoperative recovery. However, a larger experience and a longer follow up is required to define its role in the treatment of coronary artery disease.

  10. Minimal massive 3D gravity

    International Nuclear Information System (INIS)

    Bergshoeff, Eric; Merbis, Wout; Hohm, Olaf; Routh, Alasdair J; Townsend, Paul K

    2014-01-01

    We present an alternative to topologically massive gravity (TMG) with the same ‘minimal’ bulk properties; i.e. a single local degree of freedom that is realized as a massive graviton in linearization about an anti-de Sitter (AdS) vacuum. However, in contrast to TMG, the new ‘minimal massive gravity’ has both a positive energy graviton and positive central charges for the asymptotic AdS-boundary conformal algebra. (paper)

  11. Construction schedules slack time minimizing

    Science.gov (United States)

    Krzemiński, Michał

    2017-07-01

    The article presents two copyright models for minimizing downtime working brigades. Models have been developed for construction schedules performed using the method of work uniform. Application of flow shop models is possible and useful for the implementation of large objects, which can be divided into plots. The article also presents a condition describing gives which model should be used, as well as a brief example of optimization schedule. The optimization results confirm the legitimacy of the work on the newly-developed models.

  12. Acquiring minimally invasive surgical skills

    OpenAIRE

    Hiemstra, Ellen

    2012-01-01

    Many topics in surgical skills education have been implemented without a solid scientific basis. For that reason we have tried to find this scientific basis. We have focused on training and evaluation of minimally invasive surgical skills in a training setting and in practice in the operating room. This thesis has led to an enlarged insight in the organization of surgical skills training during residency training of surgical medical specialists.

  13. The importance of contact quality

    DEFF Research Database (Denmark)

    van Bakel, Marian; Gerritsen, Marinel; van Oudenhoven, Jan Pieter

    Establishing contact between expatriates and a local host has been found to reap benefits with regard to Interaction Adjustment, Host National Social Support, Open-mindedness, and Social Initiative. This longitudinal study examines the role of the quality of contact for these four aspects....... Expatriates in the Netherlands were randomly divided into an experimental group (n = 33) of which 21 developed high-quality contact with their host, and a control group (n = 32) without host. The results show that contact quality plays an important role and suggest that the higher the quality of the contact......, the more benefit the expatriate experienced. Moreover, expatriates with low-quality contact did not experience a detrimental effect....

  14. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  15. Emotional Satisfaction of Customer Contacts

    OpenAIRE

    Güngör, Hüseyin

    2007-01-01

    For marketing and customer services researchers and professionals who are interested in customer contacts, customer satisfaction and loyalty issues. Contact centers are playing a pivotal role in customer services of the 21st century. Nevertheless, despite their growing importance and presence, contact centers are increasingly becoming the center for customer frustration, and frequently associated with negative comments in the media. Therefore, this research explores the Emotional, Cognitive, ...

  16. Constructal Optimization of Top Contact Metallization of a Photovoltaic Solar Cell

    OpenAIRE

    Bhakta, Aditya; Bandyopadhyay, Santanu

    2010-01-01

    A top contact metallization of a photovoltaic solar cell collects the current generated by incident solar radiation. Several power-loss mechanisms are associated with the current flow through the front contact grid. The design of the top metal contact grid is one of the most important areas of efficient photovoltaic solar cell design. In this paper, an approach based on the constructal theory is proposed to design the grid pattern in a photovoltaic solar cell, minimizing total resistive losse...

  17. Non-contact ultrasound techniques

    International Nuclear Information System (INIS)

    Khazali Mohd Zin

    2001-01-01

    Non-contact ultrasound plays significant role in material characterisation and inspection. Unlike conventional ultrasonic techniques, non-contact ultrasonic is mostly applicable to areas where the former has its weaknesses and limitations. It is interesting to note that the non-contact ultrasonic technique has an important significant application in industry. The technique is signified by the fact that the object to be inspected is further away from the ultrasonic source, no couplant is needed and inconsistent pressure between the transducer and the specimen can be eliminated. The paper discusses some of the non-contact ultrasound technique and its applications. (Author)

  18. Occupational contact dermatitis in hairdressers

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Johansen, Jeanne Duus; Veien, Niels K

    2013-01-01

    BACKGROUND: Occupational contact dermatitis among hairdressers is frequent, owing to daily exposure to irritants and allergens. OBJECTIVES: To identify sensitization to the most common allergens associated with the occupation of hairdressing. METHODS: Patch test results of 399 hairdressers and 1995...... matched controls with contact dermatitis, registered by the Danish Contact Dermatitis Group between January 2002 and December 2011, were analysed. All patients were patch tested with the European baseline series, and hairdressers were additionally tested with the hairdressing series. RESULTS: Occupational...... contact dermatitis (p dermatitis was less commonly observed among hairdressers (21.3%) than among controls (29.4%) (p 

  19. MIA : the Minimally Invasive Autopsy

    NARCIS (Netherlands)

    B.M. Blokker (Britt)

    2018-01-01

    textabstractThe autopsy is important to keep up the high quality of modern medicine, by giving clinicians feedback on diagnostics and therapies, and providing for medical training and medical research. Nevertheless, autopsy rates have been declining in many Western countries. From 1977 through 2011,

  20. Method and apparatus for high-efficiency direct contact condensation

    Science.gov (United States)

    Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab

    1999-01-01

    A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions. and the geometric properties of the contact medium.

  1. Feminist Principles in Survivor's Groups: Out-of-Group Contact.

    Science.gov (United States)

    Rittenhouse, JoAn

    1997-01-01

    Illustrates the value of theoretical concepts from Feminist Therapy in the group treatment of women survivors. Theoretical underpinnings are supported using data taken from clinical experience and by examining group themes and out-of-group contact developed from the case sample. Principles regarding feminist groups are proposed. (RJM)

  2. 21 CFR 886.1385 - Polymethylmethacrylate (PMMA) diagnostic contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polymethylmethacrylate (PMMA) diagnostic contact lens. 886.1385 Section 886.1385 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... directly on the globe or cornea of the eye for diagnosis or therapy of intraocular abnormalities. (b...

  3. Optimization of solar cell contacts by system cost-per-watt minimization

    Science.gov (United States)

    Redfield, D.

    1977-01-01

    New, and considerably altered, optimum dimensions for solar-cell metallization patterns are found using the recently developed procedure whose optimization criterion is the minimum cost-per-watt effect on the entire photovoltaic system. It is also found that the optimum shadow fraction by the fine grid is independent of metal cost and resistivity as well as cell size. The optimum thickness of the fine grid metal depends on all these factors, and in familiar cases it should be appreciably greater than that found by less complete analyses. The optimum bus bar thickness is much greater than those generally used. The cost-per-watt penalty due to the need for increased amounts of metal per unit area on larger cells is determined quantitatively and thereby provides a criterion for the minimum benefits that must be obtained in other process steps to make larger cells cost effective.

  4. Minimal families of curves on surfaces

    KAUST Repository

    Lubbes, Niels

    2014-01-01

    A minimal family of curves on an embedded surface is defined as a 1-dimensional family of rational curves of minimal degree, which cover the surface. We classify such minimal families using constructive methods. This allows us to compute the minimal

  5. Results of high intensity afterloading irradiation with 192 iridium in the therapy of genital tumors in women under different dose rates, fractionations and total doses in comparison with conventional radium contact irradiation. Ergebnisse der High-Intensity-Afterloadingbestrahlung mit 192 Iridium in der Therapie von Genitaltumoren der Frau unter verschiedenen Dosisleistungen, Fraktionierungen und Gesamtdosen im Vergleich mit konventioneller Radiumkontaktbestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Giers, G

    1986-05-07

    In comparison to conventional radium therapy are to be evaluated the results of the high intensity afterloading technique with the help of the parameters survial rate and complication rate. Thereby were included in the examination 4 documentations of results (collum, cervix stump, corpus and vaginal carcinoma) with altogether 742 patients with 2806 single irradiations and an evaluation of the therapy after several modifications of the therapy schemes. The 5-year survival rate was in the case of collum carcinoma: 68.4%, cervix stump: 50%, corpus carcinoma: 76%, and vaginal carcinoma: 66.6%. The corresponding 3-year survival rates were: 74.2%, 80%, 84% and 70% with primary irradiation. Only with cervix stump carcinoma were the values for post-operative irradiation. The description of the irradiation results showed, that with the changing of the fractionation mode and the dose level in collum and corpus carcinoma the irreversible complications as an expression of the success of a new therapy were reduced. The for now best suited therapy schema (fractionation and dosing) are described. (TRV).

  6. Studies on the strategies of minimizing radiation damage

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hee Yong; Sohn, Young Sook

    1998-04-01

    We studied on the strategies of minimizing radiation damage in animal system. To this end we studied following areas of research (1) mechanisms involved in bone marrow damage after total body irradiation, (2) extraction of components that are useful in protecting hematopoietic system from radiation damage, (3) cell therapy approach in restoring the damaged tissue, (4) development of radioprotective chemical reagent, and (5) epidemiological study on the population that had been exposed to radiation.

  7. Studies on the strategies of minimizing radiation damage

    International Nuclear Information System (INIS)

    Chung, Hee Yong; Sohn, Young Sook

    1998-04-01

    We studied on the strategies of minimizing radiation damage in animal system. To this end we studied following areas of research 1) mechanisms involved in bone marrow damage after total body irradiation, 2) extraction of components that are useful in protecting hematopoietic system from radiation damage, 3) cell therapy approach in restoring the damaged tissue, 4) development of radioprotective chemical reagent, and 5) epidemiological study on the population that had been exposed to radiation

  8. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  9. Emotional Satisfaction of Customer Contacts

    NARCIS (Netherlands)

    Güngör, Hüseyin

    2007-01-01

    For marketing and customer services researchers and professionals who are interested in customer contacts, customer satisfaction and loyalty issues. Contact centers are playing a pivotal role in customer services of the 21st century. Nevertheless, despite their growing importance and presence,

  10. Journal of Business Research: Contact

    African Journals Online (AJOL)

    Principal Contact. Goski Alabi Mrs Institute of Professional Studies (IPS) P. 0 Box 149 Institute Of Professional Studies (IPS) Legon, Accra Ghana Phone: +233 24 64 52798. Fax: +233 21 513539. Email: goskia@yahoo.com. Support Contact. Anthony Afeadie. Phone: +233 21 500171. Email: ipsjournal@yahoo.com.

  11. Aluminum break-point contacts

    NARCIS (Netherlands)

    Heinemann, Martina; Groot, R.A. de

    1997-01-01

    Ab initio molecular dynamics is used to study the contribution of a single Al atom to an aluminum breakpoint contact during the final stages of breaking and the initial stages of the formation of such a contact. A hysteresis effect is found in excellent agreement with experiment and the form of the

  12. Contact Allergy to Neem Oil.

    NARCIS (Netherlands)

    de Groot, Anton; Jagtman, Berend A; Woutersen, Marjolijn

    2018-01-01

    A case of allergic contact dermatitis from neem oil is presented. Neem oil (synonyms: Melia azadirachta seed oil [INCI name], nim oil, margosa oil) is a vegetable (fixed) oil obtained from the seed of the neem tree Azadirachta indica by cold pressing. Contact allergy to neem oil has been described

  13. Minimal families of curves on surfaces

    KAUST Repository

    Lubbes, Niels

    2014-11-01

    A minimal family of curves on an embedded surface is defined as a 1-dimensional family of rational curves of minimal degree, which cover the surface. We classify such minimal families using constructive methods. This allows us to compute the minimal families of a given surface.The classification of minimal families of curves can be reduced to the classification of minimal families which cover weak Del Pezzo surfaces. We classify the minimal families of weak Del Pezzo surfaces and present a table with the number of minimal families of each weak Del Pezzo surface up to Weyl equivalence.As an application of this classification we generalize some results of Schicho. We classify algebraic surfaces that carry a family of conics. We determine the minimal lexicographic degree for the parametrization of a surface that carries at least 2 minimal families. © 2014 Elsevier B.V.

  14. Body contact and body language

    DEFF Research Database (Denmark)

    Winther, Helle

    2008-01-01

    and the boundaries between self and world. In western societies, the modern premises for contact are in some ways developing from close contact to virtual communication. With this breadth of perspective in mind, the ques­tion is whether conscious and experimental work with body contact and body language in move......­ment psychology and education provide potential for intense personal develop­ment as well as for social and cultural learning processes. This performative research project originates from the research project entitled, Movement Psy­chol­ogy: The Language of the Body and the Psy­chol­ogy of Movement based......Body contact and body language are unique and existential and, although culturally dependent and socially embodied, they are also universal communication forms. For small children all over the world, warm, close and nourishing body contact is fundamental to their embodied experi­ence of themselves...

  15. Numerical algorithms for contact problems in linear elastostatics

    International Nuclear Information System (INIS)

    Barbosa, H.J.C.; Feijoo, R.A.

    1984-01-01

    In this work contact problems in linear elasticity are analysed by means of Finite Elements and Mathematical Programming Techniques. The principle of virtual work leads in this case to a variational inequality which in turn is equivalent, for Hookean materials and infinitesimal strains, to the minimization of the total potential energy over the set of all admissible virtual displacements. The use of Gauss-Seidel algorithm with relaxation and projection and also Lemke's algorithm and Uzawa's algorithm for solving the minimization problem is discussed. Finally numerical examples are presented. (Author) [pt

  16. LLNL Waste Minimization Program Plan

    International Nuclear Information System (INIS)

    1990-05-01

    This document is the February 14, 1990 version of the LLNL Waste Minimization Program Plan (WMPP). Now legislation at the federal level is being introduced. Passage will result in new EPA regulations and also DOE orders. At the state level the Hazardous Waste Reduction and Management Review Act of 1989 was signed by the Governor. DHS is currently promulgating regulations to implement the new law. EPA has issued a proposed new policy statement on source reduction and recycling. This policy reflects a preventative strategy to reduce or eliminate the generation of environmentally-harmful pollutants which may be released to the air, land surface, water, or ground water. In accordance with this policy new guidance to hazardous waste generators on the elements of a Waste Minimization Program was issued. This WMPP is formatted to meet the current DOE guidance outlines. The current WMPP will be revised to reflect all of these proposed changes when guidelines are established. Updates, changes and revisions to the overall LLNL WMPP will be made as appropriate to reflect ever-changing regulatory requirements

  17. Symmetry breaking for drag minimization

    Science.gov (United States)

    Roper, Marcus; Squires, Todd M.; Brenner, Michael P.

    2005-11-01

    For locomotion at high Reynolds numbers drag minimization favors fore-aft asymmetric slender shapes with blunt noses and sharp trailing edges. On the other hand, in an inertialess fluid the drag experienced by a body is independent of whether it travels forward or backward through the fluid, so there is no advantage to having a single preferred swimming direction. In fact numerically determined minimum drag shapes are known to exhibit almost no fore-aft asymmetry even at moderate Re. We show that asymmetry persists, albeit extremely weakly, down to vanishingly small Re, scaling asymptotically as Re^3. The need to minimize drag to maximize speed for a given propulsive capacity gives one possible mechanism for the increasing asymmetry in the body plans seen in nature, as organisms increase in size and swimming speed from bacteria like E-Coli up to pursuit predator fish such as tuna. If it is the dominant mechanism, then this signature scaling will be observed in the shapes of motile micro-organisms.

  18. The masonry behaviour under contact detonation

    Directory of Open Access Journals (Sweden)

    Marin Lupoae

    2017-03-01

    Full Text Available Breaching in masonry wall as a process of quick intervention of special forces in emergency cases, may require the use of explosive charges. In order to maximize the explosive effects on the wall and to minimize the shock wave and fragments propulsion, such breaching systems usually use a water layer which cover the explosive charge. The thickness of the water layer has a significant influence both on the mitigation of unwanted effects and enhancing the demolition effect, but also increases the mass of the system which can have negative consequences on the maneuverability and rapidity of intervention, respectivly. In this respect, the paper under consideration addresses numerical and experimental research on masonry walls to determine the behavior of mortar and brick under contact detonation and to establish an optimal water layer thickness to balance the breaching system requirement related to the mass on the one hand and effects and offered protection on the other hand.

  19. [Competitive karate and the risk of HIV infection--review, risk analysis and risk minimizing strategies].

    Science.gov (United States)

    Müller-Rath, R; Mumme, T; Miltner, O; Skobel, E

    2004-03-01

    Bleeding facial injuries are not uncommon in competitive karate. Nevertheless, the risk of an infection with HIV is extremely low. Guidelines about the prevention of HIV infections are presented. Especially in contact sports and martial arts the athletes, judges and staff have to recognize and employ these recommendations. Bleeding wounds of the hands due to contact with the opponents teeth can be minimized by fist padding.

  20. Minimally invasive injectable short nanofibers of poly(glycerol sebacate) for cardiac tissue engineering

    International Nuclear Information System (INIS)

    Ravichandran, Rajeswari; Venugopal, Jayarama Reddy; Sundarrajan, Subramanian; Mukherjee, Shayanti; Sridhar, Radhakrishnan; Ramakrishna, Seeram

    2012-01-01

    Myocardial tissue lacks the ability to appreciably regenerate itself following myocardial infarction (MI) which ultimately results in heart failure. Current therapies can only retard the progression of disease and hence tissue engineering strategies are required to facilitate the engineering of a suitable biomaterial to repair MI. The aim of this study was to investigate the in vitro properties of an injectable biomaterial for the regeneration of infarcted myocardium. Fabrication of core/shell fibers was by co-axial electrospinning, with poly(glycerol sebacate) (PGS) as core material and poly-l-lactic acid (PLLA) as shell material. The PLLA was removed by treatment of the PGS/PLLA core/shell fibers with DCM:hexane (2:1) to obtain PGS short fibers. These PGS short fibers offer the advantage of providing a minimally invasive injectable technique for the regeneration of infarcted myocardium. The scaffolds were characterized by SEM, FTIR and contact angle and cell–scaffold interactions using cardiomyocytes. The results showed that the cardiac marker proteins actinin, troponin, myosin heavy chain and connexin 43 were expressed more on short PGS fibers compared to PLLA nanofibers. We hypothesized that the injection of cells along with short PGS fibers would increase cell transplant retention and survival within the infarct, compared to the standard cell injection system. (paper)

  1. Chemical basis for minimal cognition

    DEFF Research Database (Denmark)

    Hanczyc, Martin; Ikegami, Takashi

    tension between the drop of oil and its environment. We embed a chemical reaction in the oil phase that reacts with water when an oily precursor comes in contact with the water phase at the liquidliquid interface. This reaction not only powers the droplet to move in the aqueous phase but also allows...... for sustained movement. The direction of the movement is governed by a self-generated pH gradient that surrounds the droplet. In addition this self-generated gradient can be overridden by an externally imposed pH gradient, and therefore the direction of droplet motion may be controlled. Also we noticed...... that convection flow is generated inside the oil droplet to cause the movement, which was also confirmed by simulating the fluid dynamics integrated with chemical reactions (Matsuno et al., 2007, ACAL 07, Springer, p.179, Springer). We can observe that the droplet senses the gradient in the environment (either...

  2. Laparoscopic colonic resection in inflammatory bowel disease: minimal surgery, minimal access and minimal hospital stay.

    LENUS (Irish Health Repository)

    Boyle, E

    2008-11-01

    Laparoscopic surgery for inflammatory bowel disease (IBD) is technically demanding but can offer improved short-term outcomes. The introduction of minimally invasive surgery (MIS) as the default operative approach for IBD, however, may have inherent learning curve-associated disadvantages. We hypothesise that the establishment of MIS as the standard operative approach does not increase patient morbidity as assessed in the initial period of its introduction into a specialised unit, and that it confers earlier postoperative gastrointestinal recovery and reduced hospitalisation compared with conventional open resection.

  3. Comparison of foot strike patterns of barefoot and minimally shod runners in a recreational road race

    OpenAIRE

    Peter Larson

    2014-01-01

    Background: Previous studies of foot strike patterns of distance runners in road races have typically found that the overwhelming majority of shod runners initially contact the ground on the rearfoot. However, none of these studies has attempted to quantify foot strike patterns of barefoot or minimally shod runners. This study classifies foot strike patterns of barefoot and minimally shod runners in a recreational road race. Methods: High-speed video footage was obtained of 169 barefoot an...

  4. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  5. Minimization over randomly selected lines

    Directory of Open Access Journals (Sweden)

    Ismet Sahin

    2013-07-01

    Full Text Available This paper presents a population-based evolutionary optimization method for minimizing a given cost function. The mutation operator of this method selects randomly oriented lines in the cost function domain, constructs quadratic functions interpolating the cost function at three different points over each line, and uses extrema of the quadratics as mutated points. The crossover operator modifies each mutated point based on components of two points in population, instead of one point as is usually performed in other evolutionary algorithms. The stopping criterion of this method depends on the number of almost degenerate quadratics. We demonstrate that the proposed method with these mutation and crossover operations achieves faster and more robust convergence than the well-known Differential Evolution and Particle Swarm algorithms.

  6. Strategies to Minimize Antibiotic Resistance

    Directory of Open Access Journals (Sweden)

    Sang Hee Lee

    2013-09-01

    Full Text Available Antibiotic resistance can be reduced by using antibiotics prudently based on guidelines of antimicrobial stewardship programs (ASPs and various data such as pharmacokinetic (PK and pharmacodynamic (PD properties of antibiotics, diagnostic testing, antimicrobial susceptibility testing (AST, clinical response, and effects on the microbiota, as well as by new antibiotic developments. The controlled use of antibiotics in food animals is another cornerstone among efforts to reduce antibiotic resistance. All major resistance-control strategies recommend education for patients, children (e.g., through schools and day care, the public, and relevant healthcare professionals (e.g., primary-care physicians, pharmacists, and medical students regarding unique features of bacterial infections and antibiotics, prudent antibiotic prescribing as a positive construct, and personal hygiene (e.g., handwashing. The problem of antibiotic resistance can be minimized only by concerted efforts of all members of society for ensuring the continued efficiency of antibiotics.

  7. A minimally invasive smile enhancement.

    Science.gov (United States)

    Peck, Fred H

    2014-01-01

    Minimally invasive dentistry refers to a wide variety of dental treatments. On the restorative aspect of dental procedures, direct resin bonding can be a very conservative treatment option for the patient. When tooth structure does not need to be removed, the patient benefits. Proper treatment planning is essential to determine how conservative the restorative treatment will be. This article describes the diagnosis, treatment options, and procedural techniques in the restoration of 4 maxillary anterior teeth with direct composite resin. The procedural steps are reviewed with regard to placing the composite and the variety of colors needed to ensure a natural result. Finishing and polishing of the composite are critical to ending with a natural looking dentition that the patient will be pleased with for many years.

  8. Waste minimization in analytical methods

    International Nuclear Information System (INIS)

    Green, D.W.; Smith, L.L.; Crain, J.S.; Boparai, A.S.; Kiely, J.T.; Yaeger, J.S. Schilling, J.B.

    1995-01-01

    The US Department of Energy (DOE) will require a large number of waste characterizations over a multi-year period to accomplish the Department's goals in environmental restoration and waste management. Estimates vary, but two million analyses annually are expected. The waste generated by the analytical procedures used for characterizations is a significant source of new DOE waste. Success in reducing the volume of secondary waste and the costs of handling this waste would significantly decrease the overall cost of this DOE program. Selection of appropriate analytical methods depends on the intended use of the resultant data. It is not always necessary to use a high-powered analytical method, typically at higher cost, to obtain data needed to make decisions about waste management. Indeed, for samples taken from some heterogeneous systems, the meaning of high accuracy becomes clouded if the data generated are intended to measure a property of this system. Among the factors to be considered in selecting the analytical method are the lower limit of detection, accuracy, turnaround time, cost, reproducibility (precision), interferences, and simplicity. Occasionally, there must be tradeoffs among these factors to achieve the multiple goals of a characterization program. The purpose of the work described here is to add waste minimization to the list of characteristics to be considered. In this paper the authors present results of modifying analytical methods for waste characterization to reduce both the cost of analysis and volume of secondary wastes. Although tradeoffs may be required to minimize waste while still generating data of acceptable quality for the decision-making process, they have data demonstrating that wastes can be reduced in some cases without sacrificing accuracy or precision

  9. Multiscale Analysis of the Roughness Effect on Lubricated Rough Contact

    OpenAIRE

    Demirci , Ibrahim; MEZGHANI , Sabeur; YOUSFI , Mohammed; El Mansori , Mohamed

    2014-01-01

    Determining friction is as equally essential as determining the film thickness in the lubricated contact, and is an important research subject. Indeed, reduction of friction in the automotive industry is important for both the minimization of fuel consumption as well as the decrease in the emissions of greenhouse gases. However, the progress in friction reduction has been limited by the difficulty in understanding the mechanism of roughness effects on friction. It was observed that micro-surf...

  10. Nordic project food contact materials

    DEFF Research Database (Denmark)

    Li, Ågot; Tesdal Håland, Julie; Petersen, Jens Højslev

    Denmark, Finland, Faroe Islands, Iceland, Norway and Sweden have in 2013––2015 conducted a Nordic project on food contact materials. Food contact materials are used in all stages of food production and can be a general source of contamination. The food safety authorities in most of the Nordic...... countries have had a limited focus on the FCM area with the exception of Denmark and Finland. The aim of the project was therefore to control establishments producing, importing or using plastic food contact materials as well as to increase the knowledge of the inspectors performing these controls....... The focus of the inspections was to control the declaration of compliance (DoC) for plastic food contact materials. The requirement for a Doc is mandatory in order to ensure that the FCM complies with the legislation. In addition some products were analyzed for phthalates....

  11. Scalable algorithms for contact problems

    CERN Document Server

    Dostál, Zdeněk; Sadowská, Marie; Vondrák, Vít

    2016-01-01

    This book presents a comprehensive and self-contained treatment of the authors’ newly developed scalable algorithms for the solutions of multibody contact problems of linear elasticity. The brand new feature of these algorithms is theoretically supported numerical scalability and parallel scalability demonstrated on problems discretized by billions of degrees of freedom. The theory supports solving multibody frictionless contact problems, contact problems with possibly orthotropic Tresca’s friction, and transient contact problems. It covers BEM discretization, jumping coefficients, floating bodies, mortar non-penetration conditions, etc. The exposition is divided into four parts, the first of which reviews appropriate facets of linear algebra, optimization, and analysis. The most important algorithms and optimality results are presented in the third part of the volume. The presentation is complete, including continuous formulation, discretization, decomposition, optimality results, and numerical experimen...

  12. Research in Hospitality Management: Contact

    African Journals Online (AJOL)

    Principal Contact. Dr Sjoerd A Gehrels Editor-in-Chief Stenden Hotel Management School, Academy of International Hospitality Research, Leeuwarden, The Netherlands Email: sjoerd.gehrels@stenden.com ...

  13. EPA Alternative Dispute Resolution Contacts

    Science.gov (United States)

    The success of EPA's ADR efforts depends on a network of talented and experienced professionals in Headquarters offices and EPA Regions. For Agency-wide ADR information, please contact the Conflict Prevention and Resolution Center.

  14. Using Contact Work in Interactions with Adults with Learning Disabilities and Autistic Spectrum Disorders

    Science.gov (United States)

    Brooks, Sharon; Paterson, Gail

    2011-01-01

    This article describes a project about using contact work with people with learning disabilities and autistic spectrum disorder. People with learning disabilities and additional autistic spectrum disorder are at risk of becoming socially isolated because of their difficulties in interacting with others. Contact work is a form of Pre-Therapy, which…

  15. Metal semiconductor contacts and devices

    CERN Document Server

    Cohen, Simon S; Einspruch, Norman G

    1986-01-01

    VLSI Electronics Microstructure Science, Volume 13: Metal-Semiconductor Contacts and Devices presents the physics, technology, and applications of metal-semiconductor barriers in digital integrated circuits. The emphasis is placed on the interplay among the theory, processing, and characterization techniques in the development of practical metal-semiconductor contacts and devices.This volume contains chapters that are devoted to the discussion of the physics of metal-semiconductor interfaces and its basic phenomena; fabrication procedures; and interface characterization techniques, particularl

  16. Embodied Archives as Contact Zones

    Directory of Open Access Journals (Sweden)

    Judit Vidiella

    2015-02-01

    Full Text Available This article proposes a reflection about affective politics from locating some theoretical and conceptual genealogies like «emotion», «affection», «zones of contact»…, that understand them as action and force fields. These contributions allow us to rethink the relation of affects with politics and strategies of archive linked to performance, and understood as zones of friction, collision, circulation and contact: performative writing, repertoire, memes…

  17. Defining an essence of structure determining residue contacts in proteins.

    Science.gov (United States)

    Sathyapriya, R; Duarte, Jose M; Stehr, Henning; Filippis, Ioannis; Lappe, Michael

    2009-12-01

    The network of native non-covalent residue contacts determines the three-dimensional structure of a protein. However, not all contacts are of equal structural significance, and little knowledge exists about a minimal, yet sufficient, subset required to define the global features of a protein. Characterisation of this "structural essence" has remained elusive so far: no algorithmic strategy has been devised to-date that could outperform a random selection in terms of 3D reconstruction accuracy (measured as the Ca RMSD). It is not only of theoretical interest (i.e., for design of advanced statistical potentials) to identify the number and nature of essential native contacts-such a subset of spatial constraints is very useful in a number of novel experimental methods (like EPR) which rely heavily on constraint-based protein modelling. To derive accurate three-dimensional models from distance constraints, we implemented a reconstruction pipeline using distance geometry. We selected a test-set of 12 protein structures from the four major SCOP fold classes and performed our reconstruction analysis. As a reference set, series of random subsets (ranging from 10% to 90% of native contacts) are generated for each protein, and the reconstruction accuracy is computed for each subset. We have developed a rational strategy, termed "cone-peeling" that combines sequence features and network descriptors to select minimal subsets that outperform the reference sets. We present, for the first time, a rational strategy to derive a structural essence of residue contacts and provide an estimate of the size of this minimal subset. Our algorithm computes sparse subsets capable of determining the tertiary structure at approximately 4.8 A Ca RMSD with as little as 8% of the native contacts (Ca-Ca and Cb-Cb). At the same time, a randomly chosen subset of native contacts needs about twice as many contacts to reach the same level of accuracy. This "structural essence" opens new avenues in the

  18. THE CONTROL VARIATIONAL METHOD FOR ELASTIC CONTACT PROBLEMS

    Directory of Open Access Journals (Sweden)

    Mircea Sofonea

    2010-07-01

    Full Text Available We consider a multivalued equation of the form Ay + F(y = fin a real Hilbert space, where A is a linear operator and F represents the (Clarke subdifferential of some function. We prove existence and uniqueness results of the solution by using the control variational method. The main idea in this method is to minimize the energy functional associated to the nonlinear equation by arguments of optimal control theory. Then we consider a general mathematical model describing the contact between a linearly elastic body and an obstacle which leads to a variational formulation as above, for the displacement field. We apply the abstract existence and uniqueness results to prove the unique weak solvability of the corresponding contact problem. Finally, we present examples of contact and friction laws for which our results work.

  19. [Contact allergy to henna tattoos].

    Science.gov (United States)

    Steinkjer, Bjarte; Stangeland, Katarina Zak; Mikkelsen, Carsten Sauer

    2011-03-18

    Tattoos with henna colours have become very popular and the prevalence of contact allergy seems to increase. This is a short review article based on our own clinical experience and literature identified through a search in PubMed with the words "henna", "paraphenylendiamin" and "allergic contact dermatitis." A case report is included. It is well documented that many experience skin reactions after henna tattoos. The cause is almost always contact allergy to the azo compound paraphenylendiamin, which is added to speed up the process and make the colour darker. Most people, including children, get henna tattoos during vacations in Asia or the Mediterranean. Established contact allergy is permanent. Many hair-colour products contain paraphenylendiamin, and persons with contact allergy against the product may develop a very strong contact allergic eczema by use of such substances. Acute reactions are treated with local cortisone products, or with systemic steroids. Cross reaction to substances with a similar chemical structure may occur. Tattoos with paraphenylendiamin-containing henna colours should be avoided.

  20. Cyclone Simulation via Action Minimization

    Science.gov (United States)

    Plotkin, D. A.; Weare, J.; Abbot, D. S.

    2016-12-01

    A postulated impact of climate change is an increase in intensity of tropical cyclones (TCs). This hypothesized effect results from the fact that TCs are powered subsaturated boundary layer air picking up water vapor from the surface ocean as it flows inwards towards the eye. This water vapor serves as the energy input for TCs, which can be idealized as heat engines. The inflowing air has a nearly identical temperature as the surface ocean; therefore, warming of the surface leads to a warmer atmospheric boundary layer. By the Clausius-Clapeyron relationship, warmer boundary layer air can hold more water vapor and thus results in more energetic storms. Changes in TC intensity are difficult to predict due to the presence of fine structures (e.g. convective structures and rainbands) with length scales of less than 1 km, while general circulation models (GCMs) generally have horizontal resolutions of tens of kilometers. The models are therefore unable to capture these features, which are critical to accurately simulating cyclone structure and intensity. Further, strong TCs are rare events, meaning that long multi-decadal simulations are necessary to generate meaningful statistics about intense TC activity. This adds to the computational expense, making it yet more difficult to generate accurate statistics about long-term changes in TC intensity due to global warming via direct simulation. We take an alternative approach, applying action minimization techniques developed in molecular dynamics to the WRF weather/climate model. We construct artificial model trajectories that lead from quiescent (TC-free) states to TC states, then minimize the deviation of these trajectories from true model dynamics. We can thus create Monte Carlo model ensembles that are biased towards cyclogenesis, which reduces computational expense by limiting time spent in non-TC states. This allows for: 1) selective interrogation of model states with TCs; 2) finding the likeliest paths for

  1. Treatment of contact lens related dry eye with antibacterial honey.

    Science.gov (United States)

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. Contact isotopic- and contact ion-exchange between two adsorbents

    International Nuclear Information System (INIS)

    Bunzl, K.; Mohan, R.; Haimerl, M.

    1975-01-01

    The kinetics of contact ion exchange processes between an ion exchange membrane and resin ion exchange beads, stirred in pure water, was investigated. A general criterion was derived, which indicates whether diffusion of the ions between the intermingling electric double layers or the collision frequency between the two adsorbents is the rate dermining step. Since the latter process proved to be rate controlling under our experimental conditions, the corresponding rate equations were derived under various initial and boundary conditions. Experimentally, the kinetics of contact isotopic exchange of Cs + - and Na + -ions as well as of the reverse contact ion exchange process of Cs + -versus Na + -ions were investigated by using Na 22 and Cs 137 radioisotopes. The experiments reveal in quantitative accord with the theory that the rate of collision controlled contact ion exchange processes depends mainly on the 'exchange coefficient', the separation factor and the collision frequency. While the latter two quantities were determined independently by separate experiments, the 'exchange coefficient' was evaluated from a contact isotopic exchange experiment. (orig.) [de

  3. Tracing contacts of TB patients in Malaysia: costs and practicality.

    Science.gov (United States)

    Atif, Muhammad; Sulaiman, Syed Azhar Syed; Shafie, Asrul Akmal; Ali, Irfhan; Asif, Muhammad

    2012-01-01

    Tuberculin skin testing (TST) and chest X-ray are the conventional methods used for tracing suspected tuberculosis (TB) patients. The purpose of the study was to calculate the cost incurred by Penang General Hospital on performing one contact tracing procedure using an activity based costing approach. Contact tracing records (including the demographic profile of contacts and outcome of the contact tracing procedure) from March 2010 until February 2011 were retrospectively obtained from the TB contact tracing record book. The human resource cost was calculated by multiplying the mean time spent (in minutes) by employees doing a specific activity by their per-minute salaries. The costs of consumables, Purified Protein Derivative vials and clinical equipment were obtained from the procurement section of the Pharmacy and Radiology Departments. The cost of the building was calculated by multiplying the area of space used by the facility with the unit cost of the public building department. Straight-line deprecation with a discount rate of 3% was assumed for the calculation of equivalent annual costs for the building and machines. Out of 1024 contact tracing procedures, TST was positive (≥10 mm) in 38 suspects. However, chemoprophylaxis was started in none. Yield of contact tracing (active tuberculosis) was as low as 0.5%. The total unit cost of chest X-ray and TST was MYR 9.23 (2.90 USD) & MYR 11.80 (USD 3.70), respectively. The total cost incurred on a single contact tracing procedure was MYR 21.03 (USD 6.60). Our findings suggest that the yield of contact tracing was very low which may be attributed to an inappropriate prioritization process. TST may be replaced with more accurate and specific methods (interferon gamma release assay) in highly prioritized contacts; or TST-positive contacts should be administered 6H therapy (provided that the chest radiography excludes TB) in accordance with standard protocols. The unit cost of contact tracing can be significantly

  4. Solar cell with back side contacts

    Science.gov (United States)

    Nielson, Gregory N; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J; Wanlass, Mark Woodbury; Clews, Peggy J

    2013-12-24

    A III-V solar cell is described herein that includes all back side contacts. Additionally, the positive and negative electrical contacts contact compoud semiconductor layers of the solar cell other than the absorbing layer of the solar cell. That is, the positive and negative electrical contacts contact passivating layers of the solar cell.

  5. Measuring The Contact Resistances Of Photovoltaic Cells

    Science.gov (United States)

    Burger, D. R.

    1985-01-01

    Simple method devised to measure contact resistances of photovoltaic solar cells. Method uses readily available equipment and applicable at any time during life of cell. Enables evaluation of cell contact resistance, contact-end resistance, contact resistivity, sheet resistivity, and sheet resistivity under contact.

  6. Minimalism through intraoperative functional mapping.

    Science.gov (United States)

    Berger, M S

    1996-01-01

    Intraoperative stimulation mapping may be used to avoid unnecessary risk to functional regions subserving language and sensori-motor pathways. Based on the data presented here, language localization is variable in the entire population, with only certainty existing for the inferior frontal region responsible for motor speech. Anatomical landmarks such as the anterior temporal tip for temporal lobe language sites and the posterior aspect of the lateral sphenoid wing for the frontal lobe language zones are unreliable in avoiding postoperative aphasias. Thus, individual mapping to identify essential language sites has the greatest likelihood of avoiding permanent deficits in naming, reading, and motor speech. In a similar approach, motor and sensory pathways from the cortex and underlying white matter may be reliably stimulated and mapped in both awake and asleep patients. Although these techniques require an additional operative time and equipment nominally priced, the result is often gratifying, as postoperative morbidity has been greatly reduced in the process of incorporating these surgical strategies. The patients quality of life is improved in terms of seizure control, with or without antiepileptic drugs. This avoids having to perform a second costly operative procedure, which is routinely done when extraoperative stimulation and recording is done via subdural grids. In addition, an aggressive tumor resection at the initial operation lengthens the time to tumor recurrence and often obviates the need for a subsequent reoperation. Thus, intraoperative functional mapping may be best alluded to as a surgical technique that results in "minimalism in the long term".

  7. Against explanatory minimalism in psychiatry

    Directory of Open Access Journals (Sweden)

    Tim eThornton

    2015-12-01

    Full Text Available The idea that psychiatry contains, in principle, a series of levels of explanation has been criticised both as empirically false but also, by Campbell, as unintelligible because it presupposes a discredited pre-Humean view of causation. Campbell’s criticism is based on an interventionist-inspired denial that mechanisms and rational connections underpin physical and mental causation respectively and hence underpin levels of explanation. These claims echo some superficially similar remarks in Wittgenstein’s Zettel. But attention to the context of Wittgenstein’s remarks suggests a reason to reject explanatory minimalism in psychiatry and reinstate a Wittgensteinian notion of level of explanation. Only in a context broader than the one provided by interventionism is the ascription of propositional attitudes, even in the puzzling case of delusions, justified. Such a view, informed by Wittgenstein, can reconcile the idea that the ascription mental phenomena presupposes a particular level of explanation with the rejection of an a priori claim about its connection to a neurological level of explanation.

  8. Against Explanatory Minimalism in Psychiatry.

    Science.gov (United States)

    Thornton, Tim

    2015-01-01

    The idea that psychiatry contains, in principle, a series of levels of explanation has been criticized not only as empirically false but also, by Campbell, as unintelligible because it presupposes a discredited pre-Humean view of causation. Campbell's criticism is based on an interventionist-inspired denial that mechanisms and rational connections underpin physical and mental causation, respectively, and hence underpin levels of explanation. These claims echo some superficially similar remarks in Wittgenstein's Zettel. But attention to the context of Wittgenstein's remarks suggests a reason to reject explanatory minimalism in psychiatry and reinstate a Wittgensteinian notion of levels of explanation. Only in a context broader than the one provided by interventionism is that the ascription of propositional attitudes, even in the puzzling case of delusions, justified. Such a view, informed by Wittgenstein, can reconcile the idea that the ascription mental phenomena presupposes a particular level of explanation with the rejection of an a priori claim about its connection to a neurological level of explanation.

  9. Robotic assisted minimally invasive surgery

    Directory of Open Access Journals (Sweden)

    Palep Jaydeep

    2009-01-01

    Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.

  10. Can exposure limitations for well-known contact allergens be simplified? An analysis of dose-response patch test data

    DEFF Research Database (Denmark)

    Neergaard, Louise Arup; Menné, Torkil; Voelund, Aage

    2011-01-01

    Allergic contact dermatitis is triggered by chemicals in the environment. Primary prevention is aimed at minimizing the risk of induction, whereas secondary and tertiary prevention are aimed at reducing elicitation....

  11. Optical Evaluation of the Rear Contacts of Crystalline Silicon Solar Cells by Coupled Electromagnetic and Statistical Ray-Optics Modeling

    KAUST Repository

    Dabirian, Ali; Morales-Masis, Monica; Haug, Franz-Josef; De Wolf, Stefaan; Ballif, Christophe

    2017-01-01

    High-efficiency crystalline silicon (c-Si) solar cells increasingly feature sophisticated electron and hole contacts aimed at minimizing electronic losses. At the rear of photovoltaic devices, such contacts—usually consisting of stacks of functional

  12. Is non-minimal inflation eternal?

    International Nuclear Information System (INIS)

    Feng, Chao-Jun; Li, Xin-Zhou

    2010-01-01

    The possibility that the non-minimal coupling inflation could be eternal is investigated. We calculate the quantum fluctuation of the inflaton in a Hubble time and find that it has the same value as that in the minimal case in the slow-roll limit. Armed with this result, we have studied some concrete non-minimal inflationary models including the chaotic inflation and the natural inflation, in which the inflaton is non-minimally coupled to the gravity. We find that the non-minimal coupling inflation could be eternal in some parameter spaces.

  13. Early Success Is Vital in Minimal Worksite Wellness Interventions at Small Worksites

    Science.gov (United States)

    Ablah, Elizabeth; Dong, Frank; Konda, Kurt; Konda, Kelly; Armbruster, Sonja; Tuttle, Becky

    2015-01-01

    Intervention: In an effort to increase physical activity, 15 workplaces participated in a minimal-contact 10,000-steps-a-day program sponsored by the Sedgwick County Health Department in 2007 and 2008. Pedometers were provided to measure participants' weekly steps for the 10-week intervention. Method: Participants were defined as those who…

  14. Minimal nuclear energy density functional

    Science.gov (United States)

    Bulgac, Aurel; Forbes, Michael McNeil; Jin, Shi; Perez, Rodrigo Navarro; Schunck, Nicolas

    2018-04-01

    We present a minimal nuclear energy density functional (NEDF) called "SeaLL1" that has the smallest number of possible phenomenological parameters to date. SeaLL1 is defined by seven significant phenomenological parameters, each related to a specific nuclear property. It describes the nuclear masses of even-even nuclei with a mean energy error of 0.97 MeV and a standard deviation of 1.46 MeV , two-neutron and two-proton separation energies with rms errors of 0.69 MeV and 0.59 MeV respectively, and the charge radii of 345 even-even nuclei with a mean error ɛr=0.022 fm and a standard deviation σr=0.025 fm . SeaLL1 incorporates constraints on the equation of state (EoS) of pure neutron matter from quantum Monte Carlo calculations with chiral effective field theory two-body (NN ) interactions at the next-to-next-to-next-to leading order (N3LO) level and three-body (NNN ) interactions at the next-to-next-to leading order (N2LO) level. Two of the seven parameters are related to the saturation density and the energy per particle of the homogeneous symmetric nuclear matter, one is related to the nuclear surface tension, two are related to the symmetry energy and its density dependence, one is related to the strength of the spin-orbit interaction, and one is the coupling constant of the pairing interaction. We identify additional phenomenological parameters that have little effect on ground-state properties but can be used to fine-tune features such as the Thomas-Reiche-Kuhn sum rule, the excitation energy of the giant dipole and Gamow-Teller resonances, the static dipole electric polarizability, and the neutron skin thickness.

  15. Minimal models of multidimensional computations.

    Directory of Open Access Journals (Sweden)

    Jeffrey D Fitzgerald

    2011-03-01

    Full Text Available The multidimensional computations performed by many biological systems are often characterized with limited information about the correlations between inputs and outputs. Given this limitation, our approach is to construct the maximum noise entropy response function of the system, leading to a closed-form and minimally biased model consistent with a given set of constraints on the input/output moments; the result is equivalent to conditional random field models from machine learning. For systems with binary outputs, such as neurons encoding sensory stimuli, the maximum noise entropy models are logistic functions whose arguments depend on the constraints. A constraint on the average output turns the binary maximum noise entropy models into minimum mutual information models, allowing for the calculation of the information content of the constraints and an information theoretic characterization of the system's computations. We use this approach to analyze the nonlinear input/output functions in macaque retina and thalamus; although these systems have been previously shown to be responsive to two input dimensions, the functional form of the response function in this reduced space had not been unambiguously identified. A second order model based on the logistic function is found to be both necessary and sufficient to accurately describe the neural responses to naturalistic stimuli, accounting for an average of 93% of the mutual information with a small number of parameters. Thus, despite the fact that the stimulus is highly non-Gaussian, the vast majority of the information in the neural responses is related to first and second order correlations. Our results suggest a principled and unbiased way to model multidimensional computations and determine the statistics of the inputs that are being encoded in the outputs.

  16. Contact Estimation in Robot Interaction

    Directory of Open Access Journals (Sweden)

    Filippo D'Ippolito

    2014-07-01

    Full Text Available In the paper, safety issues are examined in a scenario in which a robot manipulator and a human perform the same task in the same workspace. During the task execution, the human should be able to physically interact with the robot, and in this case an estimation algorithm for both interaction forces and a contact point is proposed in order to guarantee safety conditions. The method, starting from residual joint torque estimation, allows both direct and adaptive computation of the contact point and force, based on a principle of equivalence of the contact forces. At the same time, all the unintended contacts must be avoided, and a suitable post-collision strategy is considered to move the robot away from the collision area or else to reduce impact effects. Proper experimental tests have demonstrated the applicability in practice of both the post-impact strategy and the estimation algorithms; furthermore, experiments demonstrate the different behaviour resulting from the adaptation of the contact point as opposed to direct calculation.

  17. Westinghouse Hanford Company waste minimization actions

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.

    1988-09-01

    Companies that generate hazardous waste materials are now required by national regulations to establish a waste minimization program. Accordingly, in FY88 the Westinghouse Hanford Company formed a waste minimization team organization. The purpose of the team is to assist the company in its efforts to minimize the generation of waste, train personnel on waste minimization techniques, document successful waste minimization effects, track dollar savings realized, and to publicize and administer an employee incentive program. A number of significant actions have been successful, resulting in the savings of materials and dollars. The team itself has been successful in establishing some worthwhile minimization projects. This document briefly describes the waste minimization actions that have been successful to date. 2 refs., 26 figs., 3 tabs

  18. Contact-impact algorithms on parallel computers

    International Nuclear Information System (INIS)

    Zhong Zhihua; Nilsson, Larsgunnar

    1994-01-01

    Contact-impact algorithms on parallel computers are discussed within the context of explicit finite element analysis. The algorithms concerned include a contact searching algorithm and an algorithm for contact force calculations. The contact searching algorithm is based on the territory concept of the general HITA algorithm. However, no distinction is made between different contact bodies, or between different contact surfaces. All contact segments from contact boundaries are taken as a single set. Hierarchy territories and contact territories are expanded. A three-dimensional bucket sort algorithm is used to sort contact nodes. The defence node algorithm is used in the calculation of contact forces. Both the contact searching algorithm and the defence node algorithm are implemented on the connection machine CM-200. The performance of the algorithms is examined under different circumstances, and numerical results are presented. ((orig.))

  19. Device including a contact detector

    DEFF Research Database (Denmark)

    2011-01-01

    arms (12) may extend from the supporting body in co-planar relationship with the first surface. The plurality of cantilever arms (12) may extend substantially parallel to each other and each of the plurality of cantilever arms (12) may include an electrical conductive tip for contacting the area......The present invention relates to a probe for determining an electrical property of an area of a surface of a test sample, the probe is intended to be in a specific orientation relative to the test sample. The probe may comprise a supporting body defining a first surface. A plurality of cantilever...... of the test sample by movement of the probe relative to the surface of the test sample into the specific orientation.; The probe may further comprise a contact detector (14) extending from the supporting body arranged so as to contact the surface of the test sample prior to any one of the plurality...

  20. All-graphene edge contacts

    DEFF Research Database (Denmark)

    Jacobsen, Kåre Wedel; Falkenberg, Jesper Toft; Papior, Nick Rübner

    2016-01-01

    Using ab-initio methods we investigate the possibility of three-terminalgraphene "T-junction" devices and show that these all-graphene edge contactsare energetically feasible when the 1D interface itself is free from foreignatoms. We examine the energetics of various junction structures as a func......Using ab-initio methods we investigate the possibility of three-terminalgraphene "T-junction" devices and show that these all-graphene edge contactsare energetically feasible when the 1D interface itself is free from foreignatoms. We examine the energetics of various junction structures...... to be in therange of 1-10 kΩμm which is comparable to the best contact resistance reportedfor edge-contacted graphene-metal contacts. We conclude that conductingall-carbon T-junctions should be feasible....

  1. Contact Lenses for Color Blindness.

    Science.gov (United States)

    Badawy, Abdel-Rahman; Hassan, Muhammad Umair; Elsherif, Mohamed; Ahmed, Zubair; Yetisen, Ali K; Butt, Haider

    2018-06-01

    Color vision deficiency (color blindness) is an inherited genetic ocular disorder. While no cure for this disorder currently exists, several methods can be used to increase the color perception of those affected. One such method is the use of color filtering glasses which are based on Bragg filters. While these glasses are effective, they are high cost, bulky, and incompatible with other vision correction eyeglasses. In this work, a rhodamine derivative is incorporated in commercial contact lenses to filter out the specific wavelength bands (≈545-575 nm) to correct color vision blindness. The biocompatibility assessment of the dyed contact lenses in human corneal fibroblasts and human corneal epithelial cells shows no toxicity and cell viability remains at 99% after 72 h. This study demonstrates the potential of the dyed contact lenses in wavelength filtering and color vision deficiency management. © 2018 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Methylisothiazolinone contact allergy - A review

    DEFF Research Database (Denmark)

    Lundov, M D; Krongaard, Teddy; L Menné, T

    2011-01-01

    In the early 2000s the preservative methylisothiazolinone (MI) was released as an individual preservative for industrial products and in 2005 permitted for use in cosmetic products. Up till then MI had only been used in combination with methylcholoroisthiazolinone (MCI). MCI/MI is one of the most...... frequent causes of preservative contact allergy and early studies showed that both MI and MCI are sensitizers. The prevalence of MI contact allergy is already around 1·5% and sources of exposure are associated with occupation, cosmetic products or household products. Use of MI in industrial products...... is not restricted and cases of occupational contact allergy to MI e.g. in painters are reported. The frequency of use of MI in cosmetics is low, around 1%, while up to 16·5% of household products were preserved with MI. We found 19 (1·5%) out of 1272 cosmetic products labelled with MI, primarily rinse-off products...

  3. Methylisothiazolinone contact allergy: a review

    DEFF Research Database (Denmark)

    Lundov, M D; Krongaard, T; Menné, T L

    2011-01-01

    In the early 2000s the preservative methylisothiazolinone (MI) was released as an individual preservative for industrial products and in 2005 permitted for use in cosmetic products. Up till then MI had only been used in combination with methylcholoroisthiazolinone (MCI). MCI/MI is one of the most...... frequent causes of preservative contact allergy and early studies showed that both MI and MCI are sensitizers. The prevalence of MI contact allergy is already around 1·5% and sources of exposure are associated with occupation, cosmetic products or household products. Use of MI in industrial products...... is not restricted and cases of occupational contact allergy to MI e.g. in painters are reported. The frequency of use of MI in cosmetics is low, around 1%, while up to 16·5% of household products were preserved with MI. We found 19 (1·5%) out of 1272 cosmetic products labelled with MI, primarily rinse-off products...

  4. Variable reluctance switch avoids contact corrosion and contact bounce

    Science.gov (United States)

    Watson, P. C.

    1967-01-01

    Variable reluctance switch avoids contact corrosion and bounce in a hostile environment. It consists of a wire-wound magnetic core and moveable bridge piece that alters the core flux pattern to produce an electrical output useful for switching control media.

  5. Homotopy classification of contact foliations on open contact manifolds

    Indian Academy of Sciences (India)

    64

    Let ξt, t ∈ [0, 1] be a continuous family of contact structures defined by the ... here is based on ideas that can be found in [5] and [8] and may be known to experts. ..... the bigger rectangle represents the set U ×Iε1 and the central dotted line.

  6. Contact Dynamics of EHL Contacts under Time Varying Conditions

    NARCIS (Netherlands)

    Venner, Cornelis H.; Popovici, G.; Wijnant, Ysbrand H.; Dalmaz, G.; Lubrecht, A.A.; Priest, M

    2004-01-01

    By means of numerical simulations of two situations with time varying operating conditions it is shown that the dynamic behaviour of Elasto-Hydrodynamically Lubricated contacts in terms of vibrations can be characterized as: Changes in the mutual approach lead to film thickness changes in the inlet

  7. Fragrance contact allergy in Iran.

    Science.gov (United States)

    Firooz, A; Nassiri-Kashani, M; Khatami, A; Gorouhi, F; Babakoohi, S; Montaser-Kouhsari, L; Davari, P; Dowlati, Y

    2010-12-01

    Fragrances are considered as one of the most common causes of allergic contact dermatitis. About 1-4% of the general population suffer from fragrance contact allergy (FCA). To determine the frequency of FCA and its clinical relevance in a sample of Iranian patients with history of contact and/or atopic dermatitis from January 2004 to December 2008. Standardized patch testing with 28-allergen screening series recommended by the German Contact Dermatitis Research Group and European Standard Series was used at six dermatological clinics in Iran. Fragrance allergens comprised of fragrance mix I (FM I), Myroxylon pereirae (MP; balsam of Peru), Lyral, turpentine and FM II. Fragrance contact allergy was detected in 7.2% of the patients. The frequency of positive reactions to FM I, MP and FM II were 3.7% (41/1105), 2.8% (32/1135) and 1.1% (3/267) respectively. 82.4% of the reactions to fragrance allergens were clinically relevant. The most common involved areas were hands (68.4%) and face (35.4%). Fragrance allergy predominantly affected women aged more than 40 years (P=0.008). Positive reaction to more than two allergens was significantly higher in FCA patients compared with other contact dermatitis patients (P<0.0001), and FM I, nickel and MP were the most frequent allergens in these patients. Despite less frequency of FCA in comparison with some European countries, its clinical relevance in Iranian patients seems to be high. It mostly affects the hands and the face predominantly in women aged more than 40 years. © 2010 The Authors. Journal compilation © 2010 European Academy of Dermatology and Venereology.

  8. Metal Contacts to Gallium Arsenide.

    Science.gov (United States)

    Ren, Fan

    1991-07-01

    While various high performance devices fabricated from the gallium arsenide (GaAs) and related materials have generated considerable interest, metallization are fundamental components to all semiconductor devices and integrated circuits. The essential roles of metallization systems are providing the desired electrical paths between the active region of the semiconductor and the external circuits through the metal interconnections and contacts. In this work, in-situ clean of native oxide, high temperature n-type, low temperature n-type and low temperature p-type ohmic metal systems have been studied. Argon ion mill was used to remove the native oxide prior to metal deposition. For high temperature process n-type GaAs ohmic contacts, Tungsten (W) and Tungsten Silicide (WSi) were used with an epitaxial grown graded Indium Gallium Arsenide (InGaAs) layer (0.2 eV) on GaAs. In addition, refractory metals, Molybdenum (Mo), was incorporated in the Gold-Germanium (AuGe) based on n-type GaAs ohmic contacts to replace conventional silver as barrier to prevent the reaction between ohmic metal and chlorine based plasma as well as the ohmic metallization intermixing which degrades the device performance. Finally, Indium/Gold-Beryllium (In/Au-Be) alloy has been developed as an ohmic contact for p-type GaAs to reduce the contact resistance. The Fermi-level pinning of GaAs has been dominated by the surface states. The Schottky barrier height of metal contacts are about 0.8 V regardless of the metal systems. By using p-n junction approach, barrier height of pulsed C-doped layers was achieved as high as 1.4 V. Arsenic implantation into GaAs method was also used to enhance the barrier height of 1.6 V.

  9. A Procedure for 3-D Contact Stress Analysis of Spiral Bevel Gears

    Science.gov (United States)

    Kumar, A.; Bibel, G.

    1994-01-01

    Contact stress distribution of spiral bevel gears using nonlinear finite element static analysis is presented. Procedures have been developed to solve the nonlinear equations that identify the gear and pinion surface coordinates based on the kinematics of the cutting process and orientate the pinion and the gear in space to mesh with each other. Contact is simulated by connecting GAP elements along the intersection of a line from each pinion point (parallel to the normal at the contact point) with the gear surface. A three dimensional model with four gear teeth and three pinion teeth is used to determine the contact stresses at two different contact positions in a spiral bevel gearset. A summary of the elliptical contact stress distribution is given. This information will be helpful to helicopter and aircraft transmission designers who need to minimize weight of the transmission and maximize reliability.

  10. Repulsion-based model for contact angle saturation in electrowetting.

    Science.gov (United States)

    Ali, Hassan Abdelmoumen Abdellah; Mohamed, Hany Ahmed; Abdelgawad, Mohamed

    2015-01-01

    We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.

  11. Superstring amplitudes and contact interactions

    International Nuclear Information System (INIS)

    Greensite, J.

    1987-08-01

    We show that scattering amplitudes computed from light-cone superstring field theory are divergent at tree level. The divergences can be eliminated, and supersymmetry restored, by the addition of certain counter terms to the light-cone Hamiltonian. These counter terms have the form of local contact interactions, whose existence we had previously deduced on grounds of vacuum stability, and closure of the super-Poincare algebra. The quartic contact interactions required in Type I and Type IIB superstring theories are constructed in detail. (orig.)

  12. Clinical update on contact allergy

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I

    2005-01-01

    PURPOSE OF REVIEW: The aim of this article is to review recent findings in contact allergy, regarding clinical research. RECENT FINDINGS: The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union...... a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue...

  13. CONTACT DERMATITIS AMONG CONSTRUCTION WORKERS

    Directory of Open Access Journals (Sweden)

    Ida Ayu Diah Purnama Sari

    2013-02-01

    Full Text Available Contact dermatitis is a form of skin inflammation with spongiosis or intercellular edema of the epidermis due to the interaction of irritants and allergens. While occupational contact dermatitis is an inflammation of the skin due to exposure to irritants or allergens in the workplace. One of the jobs that have a high risk of the disease are construction workers. Although the disease is rarely-threatening but can cause high morbidity and suffering for workers, so it can affect the economy and quality of life of patients.

  14. An optimized hollow microneedle for minimally invasive blood extraction.

    Science.gov (United States)

    Li, Cheng Guo; Lee, Chang Yeol; Lee, Kwang; Jung, Hyungil

    2013-02-01

    The healthcare system relies widely on biochemical information obtained from blood sample extracted via hypodermic needles, despite the invasiveness and pain associated with this procedure. Therefore, an alternative micro-scale needle for minimally invasive blood sampling is highly desirable. Traditional fabrication techniques to create microneedles do not generate needles with the combined features of a sharp tip, long length, and hollow structure concurrently. Here, we report the fabrication of a microneedle long enough to reach blood vessels and sharp enough to minimize nerve contact for minimally invasive blood extraction. The microneedle structure was precisely controlled using a drawing lithography technique, and a sharp tip angle was introduced using a laser-cutting system. We investigated the characteristics of a microneedle with a length of 1,800 μm length, an inner diameter of 60 μm, a tip diameter of 120 μm, and a 15° bevel angle through in-vitro liquid extraction and mechanical strength analysis. We demonstrated that the proposed structure results in blood extraction at a reasonable rate, and that a microneedle with this geometry can reliably penetrate skin without breaking. We integrated this microneedle into a blood extraction device to extract a 20 μl volume of mouse blood in-vivo. Our optimized, hollow microneedle can potentially be incorporated with other cutting-edge technologies such as microactuators, biosensors, and microfluidic chips to create blood analysis systems for point-of-care diagnostics.

  15. Charge properties and bacterial contact-killing of hyperbranched polyurea-polyethyleneimine coatings with various degrees of alkylation

    NARCIS (Netherlands)

    Roest, Steven; van der Mei, Henny C.; Loontjens, Ton J. A.; Busscher, Henk J.

    2015-01-01

    Coatings of immobilized-quaternary-ammonium-ions (QUAT) uniquely kill adhering bacteria upon contact. QUAT-coatings require a minimal cationic-charge surface density for effective contact-killing of adhering bacteria of around 10(14) cm(-2). Quaternization of nitrogen is generally achieved through

  16. Erythema multiforme like allergic contact dermatitis associated with laurel oil: a rare presentation.

    Science.gov (United States)

    Uzuncakmak, Tugba Kevser; Karadag, Ayse Serap; Izol, Belcin; Akdeniz, Necmettin; Cobanoglu, Bengu; Taskin, Secil

    2015-04-16

    Allergic contact dermatitis is a common skin disease, which affects approximately 20% of the population. This reaction may present with several clinical manifestations. Erythema multiforme-like allergic contact dermatitis is a rare type of non-eczematous contact dermatitis, which may lead to difficulty in diagnosis.Essential oil of Laurus nobilis is widely used in massage therapy for antiinflammatory and analgesic effects. Laurus nobilis induced contact dermatitis has been reported in the literature but an erythema multiforme-like presentation is rare.

  17. Contact symmetries and Hamiltonian thermodynamics

    International Nuclear Information System (INIS)

    Bravetti, A.; Lopez-Monsalvo, C.S.; Nettel, F.

    2015-01-01

    It has been shown that contact geometry is the proper framework underlying classical thermodynamics and that thermodynamic fluctuations are captured by an additional metric structure related to Fisher’s Information Matrix. In this work we analyse several unaddressed aspects about the application of contact and metric geometry to thermodynamics. We consider here the Thermodynamic Phase Space and start by investigating the role of gauge transformations and Legendre symmetries for metric contact manifolds and their significance in thermodynamics. Then we present a novel mathematical characterization of first order phase transitions as equilibrium processes on the Thermodynamic Phase Space for which the Legendre symmetry is broken. Moreover, we use contact Hamiltonian dynamics to represent thermodynamic processes in a way that resembles the classical Hamiltonian formulation of conservative mechanics and we show that the relevant Hamiltonian coincides with the irreversible entropy production along thermodynamic processes. Therefore, we use such property to give a geometric definition of thermodynamically admissible fluctuations according to the Second Law of thermodynamics. Finally, we show that the length of a curve describing a thermodynamic process measures its entropy production

  18. An improved diagnostic contact lens.

    Science.gov (United States)

    Smith, R J

    1979-01-01

    Modification of a standard Goldmann goniolens by reducing the curvature of the contact surface to 8.5 mm radius of curvature (from the standard curvature of 7.4 mm) enabled gonioscopy to be carried out without the nuisance of air bubbles. Images PMID:465424

  19. Stellenbosch Papers in Linguistics: Contact

    African Journals Online (AJOL)

    Mailing Address. Editors SPiL. Department of General Linguistics University of Stellenbosch Private Bag X1 Matieland, 7602. Stellenbosch South Africa. Principal Contact. Dr Kate Huddlestone Journal Manager Department of General Linguistics. University of Stellenbosch. Private Bag X1. Matieland, 7602. Stellenbosch.

  20. Ohmic contacts to semiconducting diamond

    Science.gov (United States)

    Zeidler, James R.; Taylor, M. J.; Zeisse, Carl R.; Hewett, C. A.; Delahoussaye, Paul R.

    1990-10-01

    Work was carried out to improve the electron beam evaporation system in order to achieve better deposited films. The basic system is an ion pumped vacuum chamber, with a three-hearth, single-gun e-beam evaporator. Four improvements were made to the system. The system was thoroughly cleaned and new ion pump elements, an e-gun beam adjust unit, and a more accurate crystal monitor were installed. The system now has a base pressure of 3 X 10(exp -9) Torr, and can easily deposit high-melting-temperature metals such as Ta with an accurately controlled thickness. Improved shadow masks were also fabricated for better alignment and control of corner contacts for electrical transport measurements. Appendices include: A Thermally Activated Solid State Reaction Process for Fabricating Ohmic Contacts to Semiconducting Diamond; Tantalum Ohmic Contacts to Diamond by a Solid State Reaction Process; Metallization of Semiconducting Diamond: Mo, Mo/Au, and Mo/Ni/Au; Specific Contact Resistance Measurements of Ohmic Contracts to Diamond; and Electrical Activation of Boron Implanted into Diamond.

  1. Sandia National Laboratories: Contact Us

    Science.gov (United States)

    Employment (VOE) - New Mexico and California Please submit your requests by fax OR email - not both. Fax Number: (505) 845-0097, ATTN: HR Records Email Address: HR-Records@sandia.gov HR Records' Hotline: (505 in Writing Requester's Contact Information: Requester's name, company name (if applicable), phone

  2. [Minimally invasive approach for cervical spondylotic radiculopathy].

    Science.gov (United States)

    Ding, Liang; Sun, Taicun; Huang, Yonghui

    2010-01-01

    To summarize the recent minimally invasive approach for cervical spondylotic radiculopathy (CSR). The recent literature at home and abroad concerning minimally invasive approach for CSR was reviewed and summarized. There were two techniques of minimally invasive approach for CSR at present: percutaneous puncture techniques and endoscopic techniques. The degenerate intervertebral disc was resected or nucleolysis by percutaneous puncture technique if CSR was caused by mild or moderate intervertebral disc herniations. The cervical microendoscopic discectomy and foraminotomy was an effective minimally invasive approach which could provide a clear view. The endoscopy techniques were suitable to treat CSR caused by foraminal osteophytes, lateral disc herniations, local ligamentum flavum thickening and spondylotic foraminal stenosis. The minimally invasive procedure has the advantages of simple handling, minimally invasive and low incidence of complications. But the scope of indications is relatively narrow at present.

  3. Polymicrobial Infection of the Cornea Due to Contact Lens Wear

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2016-04-01

    Full Text Available A 38-year-old male presented with pain and redness in his left eye. He had a history of wearing contact lenses. His ophthalmic examination revealed a large corneal ulcer with surrounding infiltrate. Cultures were isolated from the contact lenses, lens solutions, storage cases, and conjunctivae of both eyes and also corneal scrapings of the left eye. Fortified vancomycin and amikacin drops were started hourly. Culture results of conjunctivae of each eye and left cornea were positive for Pseudomonas aeruginosa; cultures from the contact lenses, lens solution and storage case of both eyes revealed Pseudomonas aeruginosa and Alcaligenes xylosoxidans. Polymerase chain reaction of the corneal scraping was positive for Acanthameoba. The topical antibiotics were changed with ones that both bacteria were sensitive to and anti-amoebic therapy was added. The patient had two recurrences following initial presentation despite intensive therapy. Keratitis occurred due to multiple pathogens; the relapsing course despite adequate therapy is potentially associated with this polymicrobial etiology.

  4. Corporate tax minimization and stock price reactions

    OpenAIRE

    Blaufus, Kay; Möhlmann, Axel; Schwäbe, Alexander

    2016-01-01

    Tax minimization strategies may lead to significant tax savings, which could, in turn, increase firm value. However, such strategies are also associated with significant costs, such as expected penalties and planning, agency, and reputation costs. The overall impact of firms' tax minimization strategies on firm value is, therefore, unclear. To investigate whether corporate tax minimization increases firm value, we analyze the stock price reaction to news concerning corporate tax avoidance or ...

  5. Effect of Ankle Joint Contact Angle and Ground Contact Time on Depth Jump Performance.

    Science.gov (United States)

    Phillips, Joshua H; Flanagan, Sean P

    2015-11-01

    Athletes often need to both jump high and get off the ground quickly, but getting off the ground quickly can decrease the vertical ground reaction force (VGRF) impulse, impeding jump height. Energy stored in the muscle-tendon complex during the stretch-shortening cycle (SSC) may mitigate the effects of short ground contact times (GCTs). To take advantage of the SSC, several coaches recommend "attacking" the ground with the foot in a dorsiflexed (DF) position at contact. However, the efficacy of this technique has not been tested. This investigation tested the hypotheses that shorter GCTs would lead to smaller vertical depth jump heights (VDJH), and that this difference could be mitigated by instructing the athletes to land in a DF as opposed to a plantar flexed (PF) foot position. Eighteen healthy junior college athletes performed depth jumps from a 45-cm box onto force platforms under instruction to achieve one of the 2 objectives (maximum jump height [hmax] or minimal GCT [tmin]), with one of the 2 foot conditions (DF or PF). These variations created 4 distinct jump conditions: DF-hmax, DF-tmin, PF-hmax, and PF-tmin. For all variables examined, there were no significant interactions. For all 4 conditions, the ankle was PF during landing, but the DF condition was 28.87% less PF than the PF condition. The tmin conditions had a 23.48% shorter GCT than hmax. There were no significant main effects for jump height. The peak impact force for tmin was 22.14% greater than hmax and 19.11% greater for DF compared with PF conditions. A shorter GCT did not necessitate a smaller jump height, and a less PF foot did not lead to improvements in jump height or contact time during a depth jump from a 45-cm box. The same jump height was attained in less PF and shorter GCT conditions by larger impact forces. To decrease contact time while maintaining jump height, athletes should be instructed to "get off the ground as fast as possible." This cue seems to be more important than foot

  6. Safety control and minimization of radioactive wastes

    International Nuclear Information System (INIS)

    Wang Jinming; Rong Feng; Li Jinyan; Wang Xin

    2010-01-01

    Compared with the developed countries, the safety control and minimization of the radwastes in China are under-developed. The research of measures for the safety control and minimization of the radwastes is very important for the safety control of the radwastes, and the reduction of the treatment and disposal cost and environment radiation hazards. This paper has systematically discussed the safety control and the minimization of the radwastes produced in the nuclear fuel circulation, nuclear technology applications and the process of decommission of nuclear facilities, and has provided some measures and methods for the safety control and minimization of the radwastes. (authors)

  7. Contact metallurgy optimization for ohmic contacts to InP

    DEFF Research Database (Denmark)

    Clausen, Thomas; Pedersen, Arne Skyggebjerg; Leistiko, Otto

    1991-01-01

    AuGeNi and AuZnNi metallizations to n- and p-InP were studied as a function of the annealing temperature in a Rapid Thermal Annealing (RTA) system. For n-InP (S:8×1018cm-3) a broad minimum existed from 385°C to 500°C, in which the specific contact resistance, rc, was about 10-7 ¿cm2. The lowe...

  8. Contact Lens-Related Eye Infections

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Contact Lens-Related Eye Infections Sections Contact Lens-Related Eye ... Six Steps to Avoid Contact Lens Infections Contact Lens-Related Eye Infections Leer en Español: Infecciones relacionadas ...

  9. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  10. Influence of interfacial layer on contact resistance

    NARCIS (Netherlands)

    Roy, D.; In 't Zand, M.A.A.; Delhounge, R.; Klootwijk, J.H.; Wolters, Robertus A.M.

    2008-01-01

    The contact resistance between two materials is dependent on the intrinsic properties of the materials in contact and the presence and properties of an interfacial layer at the contact. This article presents the difference in contact resistance measurements with and without the presence of a process

  11. Surface contact potential patches and Casimir force measurements

    International Nuclear Information System (INIS)

    Kim, W. J.; Sushkov, A. O.; Lamoreaux, S. K.; Dalvit, D. A. R.

    2010-01-01

    We present calculations of contact potential surface patch effects that simplify previous treatments. It is shown that, because of the linearity of Laplace's equation, the presence of patch potentials does not affect an electrostatic calibration of a two-plate Casimir measurement apparatus. Using models that include long-range variations in the contact potential across the plate surfaces, a number of experimental observations can be reproduced and explained. For these models, numerical calculations show that if a voltage is applied between the plates which minimizes the force, a residual electrostatic force persists, and that the minimizing potential varies with distance. The residual force can be described by a fit to a simple two-parameter function involving the minimizing potential and its variation with distance. We show the origin of this residual force by use of a simple parallel capacitor model. Finally, the implications of a residual force that varies in a manner different from 1/d on the accuracy of previous Casimir measurements is discussed.

  12. PREFACE: Non-contact AFM Non-contact AFM

    Science.gov (United States)

    Giessibl, Franz J.; Morita, Seizo

    2012-02-01

    This special issue is focussed on high resolution non-contact atomic force microscopy (AFM). Non-contact atomic force microscopy was established approximately 15 years ago as a tool to image conducting and insulating surfaces with atomic resolution. Since 1998, an annual international conference has taken place, and although the proceedings of these conferences are a useful source of information, several key developments warrant devoting a special issue to this subject. In the theoretic field, the possibility of supplementing established techniques such as scanning tunneling microscopy (STM) and Kelvin probe microscopy with atomically resolved force micrsoscopy poses many challenges in the calculation of contrast and contrast reversal. The surface science of insulators, self-assembled monolayers and adsorbates on insulators is a fruitful field for the application of non-contact AFM: several articles in this issue are devoted to these subjects. Atomic imaging and manipulation have been pioneered using STM, but because AFM allows the measurement of forces, AFM has had a profound impact in this field as well. Three-dimensional force spectroscopy has allowed many important insights into surface science. In this issue a combined 3D tunneling and force microscopy is introduced. Non-contact AFM typically uses frequency modulation to measure force gradients and was initially used mainly in a vacuum. As can be seen in this issue, frequency modulation is now also used in ambient conditions, allowing better spatial and force resolution. We thank all of the contributors for their time and efforts in making this special issue possible. We are also very grateful to the staff of IOP Publishing for handling the administrative aspects and for steering the refereeing process. Non-contact AFM contents Relation between the chemical force and the tunnelling current in atomic point contacts: a simple model Pavel Jelínek, Martin Ondrácek and Fernando Flores Theoretical simulation of

  13. Contact allergy epidemics and their controls

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Johansen, Jeanne Duus; Menné, Torkil

    2007-01-01

    Contact dermatitis can be severe and lead to sick leave as well as significant healthcare expenses. The aim of this review is to present the published knowledge on 6 historical epidemics of contact allergy to apply this knowledge on the prevention and control of future contact allergy epidemics. ...... to prevent contact allergy epidemics. It is essential that dermatologist, scientists, administrators, and consumers organize and structure known methods to accelerate the control of emerging contact allergens....

  14. The Troy Microneedle: A Rapidly Separating, Dissolving Microneedle Formed by Cyclic Contact and Drying on the Pillar (CCDP.

    Directory of Open Access Journals (Sweden)

    Miroo Kim

    Full Text Available In dissolving microneedle (DMN-mediated therapy, complete and rapid delivery of DMNs is critical for the desired efficacy. Traditional patch-based DMN delivery, however, may fail due to incomplete delivery from insufficient skin insertion or rapid separation of microneedles due to their strong bond to the backing film. Here, we introduce the Troy microneedle, which was created by cyclic contact and drying on the pillar (CCDP, and which enabled simultaneous complete and rapid delivery of DMN. This CCDP process could be flexibly repeated to achieve a specific desired drug dose in a DMN. We evaluated DMN separation using agarose gel, and the Troy microneedle achieved more complete and rapid separation than other, more deeply dipped DMN, primarily because of the Troy's minimal junction between the DMN and pillar. When Troy microneedles were applied to pig cadaver skin, it took only 15 s for over 90% of encapsulated rhodamine B to be delivered, compared to 2 h with application of a traditional DMN patch. In vivo skin penetration studies demonstrated rapid DMN-separation of Troy microneedles still in solid form before dissolution. The Troy microneedle overcomes critical issues associated with the low penetration efficiency of flat patch-based DMN and provides an innovative route for DMN-mediated therapy, combining patient convenience with the desire drug efficacy.

  15. The Troy Microneedle: A Rapidly Separating, Dissolving Microneedle Formed by Cyclic Contact and Drying on the Pillar (CCDP).

    Science.gov (United States)

    Kim, Miroo; Yang, Huisuk; Kim, Suyong; Lee, Chisong; Jung, Hyungil

    2015-01-01

    In dissolving microneedle (DMN)-mediated therapy, complete and rapid delivery of DMNs is critical for the desired efficacy. Traditional patch-based DMN delivery, however, may fail due to incomplete delivery from insufficient skin insertion or rapid separation of microneedles due to their strong bond to the backing film. Here, we introduce the Troy microneedle, which was created by cyclic contact and drying on the pillar (CCDP), and which enabled simultaneous complete and rapid delivery of DMN. This CCDP process could be flexibly repeated to achieve a specific desired drug dose in a DMN. We evaluated DMN separation using agarose gel, and the Troy microneedle achieved more complete and rapid separation than other, more deeply dipped DMN, primarily because of the Troy's minimal junction between the DMN and pillar. When Troy microneedles were applied to pig cadaver skin, it took only 15 s for over 90% of encapsulated rhodamine B to be delivered, compared to 2 h with application of a traditional DMN patch. In vivo skin penetration studies demonstrated rapid DMN-separation of Troy microneedles still in solid form before dissolution. The Troy microneedle overcomes critical issues associated with the low penetration efficiency of flat patch-based DMN and provides an innovative route for DMN-mediated therapy, combining patient convenience with the desire drug efficacy.

  16. Contact microscopy with synchrotron radiation

    International Nuclear Information System (INIS)

    Panessa-Warren, B.J.

    1985-10-01

    Soft x-ray contact microscopy with synchrotron radiation offers the biologist and especially the microscopist, a way to morphologically study specimens that could not be imaged by conventional TEM, STEM or SEM methods (i.e. hydrated samples, samples easily damaged by an electron beam, electron dense samples, thick specimens, unstained low contrast specimens) at spatial resolutions approaching those of the TEM, with the additional possibility to obtain compositional (elemental) information about the sample as well. Although flash x-ray sources offer faster exposure times, synchrotron radiation provides a highly collimated, intense radiation that can be tuned to select specific discrete ranges of x-ray wavelengths or specific individual wavelengths which optimize imaging or microanalysis of a specific sample. This paper presents an overview of the applications of x-ray contact microscopy to biological research and some current research results using monochromatic synchrotron radiation to image biological samples. 24 refs., 10 figs

  17. Contact angles on stretched solids

    Science.gov (United States)

    Mensink, Liz; Snoeijer, Jacco

    2017-11-01

    The surface energy of solid interfaces plays a central role in wetting, as they dictate the liquid contact angle. Yet, it has been challenging to measure the solid surface energies independently, without making use of Young's law. Here we present Molecular Dynamics (MD) simulations by which we measure the surface properties for all interfaces, including the solids. We observe change in contact angles upon stretching the solid substrates, showing that the surface energy is actually strain dependent. This is clear evidence of the so-called Shuttleworth effect, making it necessary to distinguish surface energy from surface tension. We discuss how this effect gives rise to a new class of elasto-capillary phenomena. ERC Consolidator Grant No. 616918.

  18. Clinical update on contact allergy

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I

    2005-01-01

    PURPOSE OF REVIEW: The aim of this article is to review recent findings in contact allergy, regarding clinical research. RECENT FINDINGS: The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union....... Another group of important allergens that have been studied extensively included the fragrances oak moss absolute, isoeugenol, hydroxyisohexyl 3-cyclohexene carboxaldehyde and farnesol. A new fragrance mix II has been developed for standard testing, which includes the two latter compounds. Dose response...... a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue...

  19. Contact dermatitis caused by preservatives.

    Science.gov (United States)

    Yim, Elizabeth; Baquerizo Nole, Katherine L; Tosti, Antonella

    2014-01-01

    Preservatives are biocidal chemicals added to food, cosmetics, and industrial products to prevent the growth of microorganisms. They are usually nontoxic and inexpensive and have a long shelf life. Unfortunately, they commonly cause contact dermatitis. This article reviews the most important classes of preservatives physicians are most likely to encounter in their daily practice, specifically isothiazolinones, formaldehyde and formaldehyde-releasers, iodopropynyl butylcarbamate, methyldibromoglutaronitrile, and parabens. For each preservative mentioned, the prevalence of sensitization, clinical presentation of contact dermatitis, patch testing concentrations, cross reactions, and related legislation will be discussed. Mandatory labeling of preservatives is required in some countries, but not required in others. Until policies are made, physicians and patients must be proactive in identifying potential sensitizers and removing their use. We hope that this article will serve as a guide for policy makers in creating legislation and future regulations on the use and concentration of certain preservatives in cosmetics and industrial products.

  20. Sensing with Superconducting Point Contacts

    Directory of Open Access Journals (Sweden)

    Argo Nurbawono

    2012-05-01

    Full Text Available Superconducting point contacts have been used for measuring magnetic polarizations, identifying magnetic impurities, electronic structures, and even the vibrational modes of small molecules. Due to intrinsically small energy scale in the subgap structures of the supercurrent determined by the size of the superconducting energy gap, superconductors provide ultrahigh sensitivities for high resolution spectroscopies. The so-called Andreev reflection process between normal metal and superconductor carries complex and rich information which can be utilized as powerful sensor when fully exploited. In this review, we would discuss recent experimental and theoretical developments in the supercurrent transport through superconducting point contacts and their relevance to sensing applications, and we would highlight their current issues and potentials. A true utilization of the method based on Andreev reflection analysis opens up possibilities for a new class of ultrasensitive sensors.

  1. Forces in Liquid Metal Contacts

    DEFF Research Database (Denmark)

    Duggen, Lars; Mátéfi-Tempfli, Stefan

    2014-01-01

    Using rather well known theory about capillary bridges between two electrodes we calculate the tensile force that can be applied to liquid metal contacts in the micrometer regime. Assuming circular symmetry, full wetting of the electrodes, and neglecting gravity, we present a brief review of the ...... of the necessary theory and find numerically the forces to be in the 100μN range for liquid metals as mercury and liquid Gallium suspended between electrodes of 20μm radius.......Using rather well known theory about capillary bridges between two electrodes we calculate the tensile force that can be applied to liquid metal contacts in the micrometer regime. Assuming circular symmetry, full wetting of the electrodes, and neglecting gravity, we present a brief review...

  2. Minimizing electrode contamination in an electrochemical cell

    Science.gov (United States)

    Kim, Yu Seung; Zelenay, Piotr; Johnston, Christina

    2014-12-09

    An electrochemical cell assembly that is expected to prevent or at least minimize electrode contamination includes one or more getters that trap a component or components leached from a first electrode and prevents or at least minimizes them from contaminating a second electrode.

  3. Matthew Arnold and Minimal Competency Testing.

    Science.gov (United States)

    Tuman, Myron C.

    1979-01-01

    Presents arguments by Robert Lowe and Matthew Arnold on the 19th century British "Payment by Results" Plan, whereby schools received funds for students who passed minimal competency tests. Emphasizes that the Victorian experience produced acrimonious teachers with low morale and encourages contemporary minimal testing advocates not to…

  4. Minimally processed fruit salad enriched with Lactobacillus ...

    African Journals Online (AJOL)

    paula

    2015-06-17

    Jun 17, 2015 ... Minimal processing promotes browning of some vegetal tissues due to cell membrane disruption, which results in the release of oxidative enzymes. This study evaluated the efficiency of citric acid, ascorbic acid, sodium metabisulfite and L-cysteine hydrochloride to retard enzymatic browning of minimally.

  5. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  6. Y-12 Plant waste minimization strategy

    International Nuclear Information System (INIS)

    Kane, M.A.

    1987-01-01

    The 1984 Amendments to the Resource Conservation and Recovery Act (RCRA) mandate that waste minimization be a major element of hazardous waste management. In response to this mandate and the increasing costs for waste treatment, storage, and disposal, the Oak Ridge Y-12 Plant developed a waste minimization program to encompass all types of wastes. Thus, waste minimization has become an integral part of the overall waste management program. Unlike traditional approaches, waste minimization focuses on controlling waste at the beginning of production instead of the end. This approach includes: (1) substituting nonhazardous process materials for hazardous ones, (2) recycling or reusing waste effluents, (3) segregating nonhazardous waste from hazardous and radioactive waste, and (4) modifying processes to generate less waste or less toxic waste. An effective waste minimization program must provide the appropriate incentives for generators to reduce their waste and provide the necessary support mechanisms to identify opportunities for waste minimization. This presentation focuses on the Y-12 Plant's strategy to implement a comprehensive waste minimization program. This approach consists of four major program elements: (1) promotional campaign, (2) process evaluation for waste minimization opportunities, (3) waste generation tracking system, and (4) information exchange network. The presentation also examines some of the accomplishments of the program and issues which need to be resolved

  7. Making the Most of Minimalism in Music.

    Science.gov (United States)

    Geiersbach, Frederick J.

    1998-01-01

    Describes the minimalist movement in music. Discusses generations of minimalist musicians and, in general, the minimalist approach. Considers various ways that minimalist strategies can be integrated into the music classroom focusing on (1) minimalism and (2) student-centered composition and principles of minimalism for use with elementary band…

  8. The relative volume growth of minimal submanifolds

    DEFF Research Database (Denmark)

    Markvorsen, Steen; Palmer, V.

    2002-01-01

    The volume growth of certain well-defined subsets of minimal submanifolds in riemannian spaces are compared with the volume growth of balls and spheres ill space forms of constant curvature.......The volume growth of certain well-defined subsets of minimal submanifolds in riemannian spaces are compared with the volume growth of balls and spheres ill space forms of constant curvature....

  9. Specialized minimal PDFs for optimized LHC calculations

    NARCIS (Netherlands)

    Carrazza, Stefano; Forte, Stefano; Kassabov, Zahari; Rojo, Juan

    2016-01-01

    We present a methodology for the construction of parton distribution functions (PDFs) designed to provide an accurate representation of PDF uncertainties for specific processes or classes of processes with a minimal number of PDF error sets: specialized minimal PDF sets, or SM-PDFs. We construct

  10. Minimally processed fruit salad enriched with Lactobacillus ...

    African Journals Online (AJOL)

    Minimal processing promotes browning of some vegetal tissues due to cell membrane disruption, which results in the release of oxidative enzymes. This study evaluated the efficiency of citric acid, ascorbic acid, sodium metabisulfite and L-cysteine hydrochloride to retard enzymatic browning of minimally processed fruit ...

  11. Sex Therapy

    Science.gov (United States)

    Sex therapy Overview Sex therapy is a type of psychotherapy — a general term for treating mental health problems by talking with a mental health professional. Through sex therapy, you can address concerns about sexual function, ...

  12. Family Therapy

    Science.gov (United States)

    Family therapy Overview Family therapy is a type of psychological counseling (psychotherapy) that can help family members improve communication and resolve conflicts. Family therapy is usually provided by a psychologist, ...

  13. Contact interactions of closed superstrings

    International Nuclear Information System (INIS)

    Greensite, J.

    1987-07-01

    It is shown that closed light-cone superstring field theory, which is presently formulated with only cubic interaction terms, does not have a stable ground state, and that the global supersymmetry algebra is violated at second order in the coupling. Local contact interactions, of quartic (and possibly higher) order in the string fields, must be added to the light-cone Hamiltonian to restore supersymmetry and vacuum stability. (orig.)

  14. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    Science.gov (United States)

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  15. Characteristic analysis of a traveling wave ultrasonic motor using an ellipsoidal static contact model

    International Nuclear Information System (INIS)

    Lim, Jung Pil; Rho, Jong Seok; Yi, Kyung Pyo; Jung, Hyun Kyo; Seo, Jung Moo

    2009-01-01

    A characteristic analysis of an ultrasonic motor (USM) at the design stage has thus far been impossible. Therefore, a characteristic analysis method is suggested on the basis of a proposed model describing the complex nonlinear contact condition between the rotor and stator. The proposed contact model and analysis method can guide theoretical research on the minimization of the main disadvantages of the USM, which mainly result from the contact mechanism. The validity and usefulness of the suggested analysis method is verified by experimental data from a prototyped USM

  16. Prospective multicenter survey on the clinical management of pediatric contact dermatitis.

    Science.gov (United States)

    Ruggiero, Giuseppe; Carnevale, Claudia; Diociaiuti, Andrea; Arcangeli, Fabio; El Hachem, May

    2016-12-01

    Contact dermatitis can be defined as an inflammatory process affecting the skin surface and induced by contact with chemical, physical and/or biotic agents in the environment. It causes lesions to skin, mucosae and semi-mucosae by means of allergic and irritant pathogenic mechanisms. Among the main triggers of contact dermatitis in the pediatric age are chemical or physical agents, which cause irritant contact dermatitis (ICD), and sensitizers, which cause a tissue damage through an allergic mechanism (allergic contact dermatitis [ACD]). A prospective, multicenter, observational study was carried out in 204 children affected by contact dermatitis, aged up to 14 years, and enrolled by pediatricians from 7 different Italian provinces. The diagnosis of contact dermatitis was based on the pediatrician's clinical evaluation. The data were collected through a series of simple and multiple choice questions, anonymously filled out by pediatricians. In 90% of cases (184 of 204 patients), there was complete remission of contact dermatitis, with no cases of worsening. No adverse events were observed, either. The effectiveness of the therapy was rated as "very effective" by 84.4% of the parents and 86.8% of the pediatricians. In only 10 patients a new therapy had to be prescribed. Contact dermatitis is a heterogeneous inflammatory skin disease induced by contact with different kinds of environmental agents. Cutaneous manifestations are highly variable and depend on the modality of contact, on the causative agent and on the pathogenesis. This Italian experience of a clinical approach to contact dermatitis stresses the need of daily skin care through different therapeutic strategies, based on the diagnosis, the clinical severity and the parents and children compliance. The first therapeutic measure to be implemented is prevention, through the removal of the causative agent and the use of protective devices. Indeed, preserving the skin's barrier function is an important goal and

  17. Block Copolymer Adhesion Measured by Contact Mechanics Methods

    Science.gov (United States)

    Falsafi, A.; Bates, S.; Tirrell, M.; Pocius, A. V.

    1997-03-01

    Adhesion measurements for a series of polyolefin diblocks and triblocks are presented. These materials have poly(ethylene-propylene) or poly(ethyl-ethylene) rubbery block, and semicrystalline polyethylene block as physical crosslinker. The experiments consist of compression and decompression profiles of contact area between the samples as a function of normal load, analyzed by the JKR Theory. The samples are prepared either by formation of caps from the bulk material in melting and subsequent cooling, and/or coating them in thin films on surface modified elastic foundations of polydimethylsiloxane caps. The latter minimizes the viscoelastic losses which are dominant in the bulk of material. The effect of molecular architecture and microstructure on adhesion energy and dynamics of separation, obtained from decompression experiments, is discussed in view of their influence on molecular arrangements at the contacting surfaces.

  18. Effect of implanted doses of N+-ions on the contact resistance of copper contacts

    International Nuclear Information System (INIS)

    Dubravec, B.; Kovac, P.; Lipka, F.; Padysak, M.

    1997-01-01

    The paper deals with the effect of implanted doses of N + ions on the contact resistance. Dependencies of the contact resistance versus contact force R c =f(F c ) and microhardness of implanted surfaces were measured for three implanted profiles. The influence of the aggressive environs on the contact resistance of implanted contact is given too

  19. Childhood contact predicts hemispheric asymmetry in cross-race face processing.

    Science.gov (United States)

    Davis, Megan M; Hudson, Sean M; Ma, Debbie S; Correll, Joshua

    2016-06-01

    Participants typically process same-race faces more quickly and more accurately than cross-race faces. This deficit is amplified in the right hemisphere of the brain, presumably due to its involvement in configural processing. The present research tested the idea that cross-race contact tunes cognitive and perceptual systems, influencing this asymmetric race-based deficit in face processing. Participants with high and low levels of contact performed a lateralized recognition task with same- and cross-race faces. Replicating prior work, participants with minimal contact showed cross-race deficits in processing that were larger in the right hemisphere. For participants with more contact, this lateralized deficit disappeared. This effect of contact seems to be independent of race-based attitudes (e.g., prejudice).

  20. Theories of minimalism in architecture: Post scriptum

    Directory of Open Access Journals (Sweden)

    Stevanović Vladimir

    2012-01-01

    Full Text Available Owing to the period of intensive development in the last decade of XX century, architectural phenomenon called Minimalism in Architecture was remembered as the Style of the Nineties, which is characterized, morphologically speaking, by simplicity and formal reduction. Simultaneously with its development in practice, on a theoretical level several dominant interpretative models were able to establish themselves. The new millennium and time distance bring new problems; therefore this paper represents a discussion on specific theorization related to Minimalism in Architecture that can bear the designation of post scriptum, because their development starts after the constitutional period of architectural minimalist discourse. In XXI century theories, the problem of definition of minimalism remains important topic, approached by theorists through resolving on the axis: Modernism - Minimal Art - Postmodernism - Minimalism in Architecture. With regard to this, analyzed texts can be categorized in two groups: 1 texts of affirmative nature and historical-associative approach in which minimalism is identified with anything that is simple and reduced, in an idealizing manner, relied mostly on the existing hypotheses; 2 critically oriented texts, in which authors reconsider adequacy of the very term 'minimalism' in the context of architecture and take a metacritical attitude towards previous texts.