  1. 106-17 Telemetry Standards Digitized Audio Telemetry Standard Chapter 5

    Science.gov (United States)

    2017-07-01

    Digitized Audio Telemetry Standard 5.1 General This chapter defines continuously variable slope delta (CVSD) modulation as the standard for digitizing...audio signal. The CVSD modulator is, in essence , a 1-bit analog-to-digital converter. The output of this 1-bit encoder is a serial bit stream, where

  2. BROADBAND DIGITAL GEOPHYSICAL TELEMETRY SYSTEM.

    Science.gov (United States)

    Seeley, Robert L.; Daniels, Jeffrey J.

    1984-01-01

    A system has been developed to simultaneously sample and transmit digital data from five remote geophysical data receiver stations to a control station that processes, displays, and stores the data. A microprocessor in each remote station receives commands from the control station over a single telemetry channel.

  3. A battery-free multichannel digital neural/EMG telemetry system for flying insects.

    Science.gov (United States)

    Thomas, Stewart J; Harrison, Reid R; Leonardo, Anthony; Reynolds, Matthew S

    2012-10-01

    This paper presents a digital neural/EMG telemetry system small enough and lightweight enough to permit recording from insects in flight. It has a measured flight package mass of only 38 mg. This system includes a single-chip telemetry integrated circuit (IC) employing RF power harvesting for battery-free operation, with communication via modulated backscatter in the UHF (902-928 MHz) band. An on-chip 11-bit ADC digitizes 10 neural channels with a sampling rate of 26.1 kSps and 4 EMG channels at 1.63 kSps, and telemeters this data wirelessly to a base station. The companion base station transceiver includes an RF transmitter of +36 dBm (4 W) output power to wirelessly power the telemetry IC, and a digital receiver with a sensitivity of -70 dBm for 10⁻⁵ BER at 5.0 Mbps to receive the data stream from the telemetry IC. The telemetry chip was fabricated in a commercial 0.35 μ m 4M1P (4 metal, 1 poly) CMOS process. The die measures 2.36 × 1.88 mm, is 250 μm thick, and is wire bonded into a flex circuit assembly measuring 4.6 × 6.8 mm.

  4. Combined radar and telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Rodenbeck, Christopher T.; Young, Derek; Chou, Tina; Hsieh, Lung-Hwa; Conover, Kurt; Heintzleman, Richard

    2017-08-01

    A combined radar and telemetry system is described. The combined radar and telemetry system includes a processing unit that executes instructions, where the instructions define a radar waveform and a telemetry waveform. The processor outputs a digital baseband signal based upon the instructions, where the digital baseband signal is based upon the radar waveform and the telemetry waveform. A radar and telemetry circuit transmits, simultaneously, a radar signal and telemetry signal based upon the digital baseband signal.

  5. Digital intelligent booster for DCC miniature train networks

    Science.gov (United States)

    Ursu, M. P.; Condruz, D. A.

    2017-08-01

    Modern miniature trains are now driven by means of the DCC (Digital Command and Control) system, which allows the human operator or a personal computer to launch commands to each individual train or even to control different features of the same train. The digital command station encodes these commands and sends them to the trains by means of electrical pulses via the rails of the railway network. Due to the development of the miniature railway network, it may happen that the power requirement of the increasing number of digital locomotives, carriages and accessories exceeds the nominal output power of the digital command station. This digital intelligent booster relieves the digital command station from powering the entire railway network all by itself, and it automatically handles the multiple powered sections of the network. This electronic device is also able to detect and process short-circuits and overload conditions, without the intervention of the digital command station.

  6. Digitization of Electrocardiogram From Telemetry Prior to In-hospital Cardiac Arrest: A Pilot Study.

    Science.gov (United States)

    Attin, Mina; Wang, Lu; Soroushmehr, S M Reza; Lin, Chii-Dean; Lemus, Hector; Spadafore, Maxwell; Najarian, Kayvan

    2016-03-01

    Analyzing telemetry electrocardiogram (ECG) data over an extended period is often time-consuming because digital records are not widely available at hospitals. Investigating trends and patterns in the ECG data could lead to establishing predictors that would shorten response time to in-hospital cardiac arrest (I-HCA). This study was conducted to validate a novel method of digitizing paper ECG tracings from telemetry systems in order to facilitate the use of heart rate as a diagnostic feature prior to I-HCA. This multicenter study used telemetry to investigate full-disclosure ECG papers of 44 cardiovascular patients obtained within 1 hr of I-HCA with initial rhythms of pulseless electrical activity and asystole. Digital ECGs were available for seven of these patients. An algorithm to digitize the full-disclosure ECG papers was developed using the shortest path method. The heart rate was measured manually (averaging R-R intervals) for ECG papers and automatically for digitized and digital ECGs. Significant correlations were found between manual and automated measurements of digitized ECGs (p < .001) and between digitized and digital ECGs (p < .001). Bland-Altman methods showed bias = .001 s, SD = .0276 s, lower and upper 95% limits of agreement for digitized and digital ECGs = .055 and -.053 s, and percentage error = 0.22%. Root mean square (rms), percentage rms difference, and signal to noise ratio values were in acceptable ranges. The digitization method was validated. Digitized ECG provides an efficient and accurate way of measuring heart rate over an extended period of time. © The Author(s) 2015.

  7. Comparison of freely-moving telemetry Chinese Miniature Experiment Pigs (CMEPs) to beagle dogs in cardiovascular safety pharmacology studies.

    Science.gov (United States)

    Yuan, Haitao; Zhao, Jing; Guo, Jiabin; Wu, Ruiqin; He, Li; Cui, Yaxiong; Feng, Min; Zhang, Tingfen; Hou, Mingyue; Guo, Qian; Zhang, Lijun; Jia, Li; Huang, Chang; Ye, Lin; Peng, Shuangqing

    2014-01-01

    Telemetry beagle dogs are the most frequently used species in cardiovascular telemetry assessments. However, beagle dogs may not be always suitable for all of the tests. Recently minipigs have received increased attention for these studies. Differences between the two species regarding the response of their cardiovascular systems to environmental stimuli are unclear. This study investigates how the telemetry minipig compares to beagle dog as a test subject and also refines the experimental protocols necessary to obtain accurate data. Beagle dogs and Chinese Miniature Experiment Pigs (CMEPs) were implanted with telemetry transmitters and the influences of gavage, feeding and the circadian cycle on various cardiovascular parameters were investigated. ECG signal quality from CMEPs was superior to that of the beagle dogs. Poor ECG signal quality, elevated HR, BP and locomotor activity associated with gavage and feeding were observed in both species. ECG signal quality, BP and locomotor activity recovered more quickly in the CMEPs than in the beagle dogs. Residual elevation of HR found in CMEPs lasted approximately 4h post-feeding, which has a profound influence on the circadian cycle. A diurnal rhythm in CMEP with a significant increase of body temperature during the dark period and a clear circadian rhythm of locomotor activity in both species were observed. The present data demonstrated that gavage, feeding and circadian cycle were having an enormous influence on BP, HR and locomotor activity in both species. If drug-induced effects are expected rapidly after oral administration and feeding, CMEP seems to be a favorable choice. Also, due to the effects of feeding on HR, CMEPs should fast at least 5h before the start of recording or should not be fed during the study where the Tmax of a given compound might occur very late. It also should be taken into consideration when the test article has a potential effect on body temperature by using CMEPs. In summary, the

  8. Telemetry Standards, RCC Standard 106-17. Chapter 8. Digital Data Bus Acquisition Formatting Standard

    Science.gov (United States)

    2017-07-01

    incorrect word count/message and illegal mode codes are not considered bus errors. 8.6.2 Source Signal The source of data is a signal conforming to...Telemetry Standards, RCC Standard 106-17 Chapter 8, July 2017 CHAPTER 8 Digital Data Bus Acquisition Formatting Standard Acronyms...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation

  9. 106-17 Telemetry Standards Front Matter

    Science.gov (United States)

    2017-07-01

    Frequency Division Multiplexing Telemetry Standards CHAPTER 4: Pulse Code Modulation Standards CHAPTER 5: Digitized Audio Telemetry Standard CHAPTER 6...Transfer Standard Chapter 9, Appendix 9-A Appendix I, Telemetry Attributes Transfer Standard Cover Sheet Chapter 9, Appendix 9-B Telemetry Standards...Derived Parameter Specification Chapter 9, Appendix 9-E Appendix Q, Extended Binary Golay Code Chapter 7, Appendix 7-A Appendix R, Low-Density Parity

  10. A low-power and high-precision miniaturized digital sun sensor

    NARCIS (Netherlands)

    Boer, B.M. de; Durkut, M.

    2013-01-01

    A prototype miniaturized digital sun sensor (miniDSS) was developed by TNO. It is expected to be launched on QuadSat for in-orbit demonstration. The single-chip sun sensor comprises an application specific integrated circuit (ASIC) on which an active pixel sensor (APS), read-out and processing

  11. Test Methods for Telemetry Systems and Subsystems. Volume 5: Test Methods for Digital Recorder/Reproducer Systems and Recorder Memory Modules

    Science.gov (United States)

    2016-09-26

    Commanders Council. “Digital Data Bus Acquisition Formatting Standard” in Telemetry Standards. RCC 106-13. June 2013. Superseded by Telemetry...second after startup and within one second of stopping should be evaluated. The METS validation software must be configured to mirror the... startup of the recorder. A log file from a test with no errors should look something similar to Table 6-3. Configurations M_01-01 through M_02-02

  12. A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    Science.gov (United States)

    Kong, Wei; Huang, Jian; Rollins, Dennis L; Ideker, Raymond E; Smith, William M

    2007-03-01

    We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and coronary artery blood flow and arterial blood pressure that are suitable for use with the system. The telemetry system consists of a front end, a backpack and a host PC. The front end is a watertight stainless steel case with all sensor electronics sealed inside; it acquires dimension, flow, pressure and five cardiac electrograms from selected locations on the heart. The backpack includes a control unit, Bluetooth radio, and batteries. The control unit digitizes eight channels of data from the front end and forwards them to the host PC via Bluetooth link. The host PC has a receiving Bluetooth radio and Labview programs to store and display data. The whole system was successfully tested on the bench and in an animal model. This telemetry system will greatly enhance the ability to study events leading to spontaneous sudden cardiac arrest.

  13. MiniDSS: a low-power and high-precision miniaturized digital sun sensor

    NARCIS (Netherlands)

    Boer, B.M. de; Durkut, M.; Laan, E.; Hakkesteegt, H.; Theuwissen, A.; Xie, N.; Leijtens, J.L.; Urquijo, E.; Bruins, P.

    2012-01-01

    A high-precision and low-power miniaturized digital sun sensor has been developed at TNO. The single-chip sun sensor comprises an application specific integrated circuit (ASIC) on which an active pixel sensor (APS), read-out and processing circuitry as well as communication circuitry are combined.

  14. Miniaturized digital fluxgate magnetometer for small spacecraft applications

    International Nuclear Information System (INIS)

    Forslund, Åke; Ivchenko, Nickolay; Olsson, Göran; Edberg, Terry; Belyayev, Serhiy; Marusenkov, Andriy

    2008-01-01

    A novel design of an Earth field digital fluxgate magnetometer is presented, the small magnetometer in low-mass experiment (SMILE). The combination of a number of new techniques results in significant miniaturization of both sensor and electronics. The design uses a sensor with volume compensation, combining three dual rod cores in a Macor® cube with the side dimension of 20 mm. Use of volume compensation provides high geometrical stability of the axes and improved performance compared to component compensated sensors. The sensor is operated at an excitation frequency of 8 kHz. Most of the instrument functionality is combined in a digital signal processing core, implemented in a field programmable gate array (FPGA). The pick-up signal is digitized after amplification and filtering, and values of compensation currents for each of the axes are determined by a digital correlation algorithm, equivalent to a matched filter, and are fed to a hybrid pulse-width modulation/delta-sigma digital-to-analogue converter driving the currents through the compensation coils. Using digital design makes the instrument very flexible, reduces power consumption and opens possibilities for the customization of the operation modes. The current implementation of the design is based on commercial off-the-shelf components. A calibration of the SMILE instrument was carried out at the Nurmijärvi Geophysical Observatory, showing high linearity (within 6 nT on the whole ±50 µT scale), good orthogonality (22 arcmin) and very good temperature stability of the axes

  15. GTAG: architecture and design of miniature transmitter with position logging for radio telemetry

    Science.gov (United States)

    Řeřucha, Šimon; Bartonička, Tomáš; Jedlička, Petr

    2011-10-01

    The radio telemetry is a well-known technique used within zoological research to exploit the behaviour of animal species. A usage of GPS for a frequent and precise position recording gives interesting possibility for a further enhancement of this method. We present our proposal of an architecture and design concepts of telemetry transmitter with GPS module, called GTAG, that is suited for study of the Egyptian fruit bat (Rousettus aegyptiacus). The model group we study set particular constrains, especially the weight limit (9 g) and prevention of any power resources recharging technique. We discuss the aspect of physical realization and the energyconsumption issues. We have developed a reference implementation that has been already deployed during telemetry sessions and we evaluate the experience and compare the estimated performance of our device to a real data.

  16. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  17. A digital miniature x-ray tube with a high-density triode carbon nanotube field emitter

    International Nuclear Information System (INIS)

    Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Kim, Jae-Woo; Song, Yoon-Ho; Ahn, Seungjoon

    2013-01-01

    We have fabricated a digital miniature x-ray tube (6 mm in diameter and 32 mm in length) with a high-density triode carbon nanotube (CNT) field emitter for special x-ray applications. The triode CNT emitter was densely formed within a diameter of below 4 mm with the focusing-functional gate. The brazing process enables us to obtain and maintain a desired vacuum level for the reliable electron emission from the CNT emitters after the vacuum packaging. The miniature x-ray tube exhibited a stable and reliable operation over 250 h in a pulse mode at an anode voltage of above 25 kV.

  18. MiniDSS: a low-power and high-precision miniaturized digital sun sensor

    Science.gov (United States)

    de Boer, B. M.; Durkut, M.; Laan, E.; Hakkesteegt, H.; Theuwissen, A.; Xie, N.; Leijtens, J. L.; Urquijo, E.; Bruins, P.

    2017-11-01

    A high-precision and low-power miniaturized digital sun sensor has been developed at TNO. The single-chip sun sensor comprises an application specific integrated circuit (ASIC) on which an active pixel sensor (APS), read-out and processing circuitry as well as communication circuitry are combined. The design was optimized for low recurrent cost. The sensor is albedo insensitive and the prototype combines an accuracy in the order of 0.03° with a mass of just 72 g and a power consumption of only 65 mW.

  19. Development of telemetry for high-speed rotor instrumentation and monitoring: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Mallick, G.T.; Nenno, P.N.; Parker, J.H.; Eckels, P.W.

    1987-06-01

    A modern data acquisition and telemetry system for rotating systems was developed as a part of a program, jointly funded by EPRI and Westinghouse, to develop a 300 MVA superconducting generator. While the overall program was terminated before completion, the telemetry development task was essentially complete at termination. It had been planned that the data acquisition and telemetry system was to be used in large scale models and the final 300 MVA rotor testing for transmitting sensor data from the rotating frame. An important part of this development was the qualification of a number of cryogenic sensors that were to be used in conjunction with the telemetry system for measuring temperature, strain and liquid helium level. The telemetry system that was developed handled the data transmission by digital frequency shift keying with a carrier of 200 kHz. The analog sensor signals were amplified and filtered ''on-board'' before being multiplexed and converted to a digital signal. All of this was under the control of a single chip microcomputer (Intel 8748) in the rotating frame. The overall sensor, data acquisition and telemetry system were operated and tested under rotation for a period of over one hundred hours. Overall, the system has proven itself to be reliable and effective. The present report covers all aspects of this development in detail, including the circuit and software design and performance. 27 refs., 58 figs.

  20. Seven-channel digital telemetry system for monitoring and direct computer capturing of biological data.

    Science.gov (United States)

    Drewes, A M; Andreasen, A; Assentoft, J E; Nagel, O

    1993-09-01

    A seven-channel telemetry system for collection and display of biological data is presented. The system can amplify bioelectrical signals in the range of 2 microV to 200 mV and has a bandwidth of 0.1-80 Hz. After multiplexing, the signals are digitized with a resolution of 8 bits. The data are frequency modulated directly on a VHF transmitter. After receiving the data on a VHF receiver, they are routed directly to the RS232 input connector on the PC. Thereby the advantage of direct communication between the transmitter and the PC can be utilized. Expensive analog equipment is avoided and display of the signals on the PC screen as well as signal analysis can be performed. The system has been tested and was found to be stable and highly reliable.

  1. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    International Nuclear Information System (INIS)

    Jia, Zhiwei; Yan, Guozheng; Zhu, Bingquan

    2015-01-01

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system

  2. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  3. Miniature, Single Channel, Memory-Based, High-G Acceleration Recorder (Millipen)

    International Nuclear Information System (INIS)

    Rohwer, Tedd A.

    1999-01-01

    The Instrumentation and Telemetry Departments at Sandia National Laboratories have been instrumenting earth penetrators for over thirty years. Recorded acceleration data is used to quantify penetrator performance. Penetrator testing has become more difficult as desired impact velocities have increased. This results in the need for small-scale test vehicles and miniature instrumentation. A miniature recorder will allow penetrator diameters to significantly decrease, opening the window of testable parameters. Full-scale test vehicles will also benefit from miniature recorders by using a less intrusive system to instrument internal arming, fusing, and firing components. This single channel concept is the latest design in an ongoing effort to miniaturize the size and reduce the power requirement of acceleration instrumentation. A micro-controller/memory based system provides the data acquisition, signal conditioning, power regulation, and data storage. This architecture allows the recorder, including both sensor and electronics, to occupy a volume of less than 1.5 cubic inches, draw less than 200mW of power, and record 15kHz data up to 40,000 gs. This paper will describe the development and operation of this miniature acceleration recorder

  4. Rodent scope: a user-configurable digital wireless telemetry system for freely behaving animals.

    Directory of Open Access Journals (Sweden)

    David Ball

    Full Text Available This paper describes the design and implementation of a wireless neural telemetry system that enables new experimental paradigms, such as neural recordings during rodent navigation in large outdoor environments. RoSco, short for Rodent Scope, is a small lightweight user-configurable module suitable for digital wireless recording from freely behaving small animals. Due to the digital transmission technology, RoSco has advantages over most other wireless modules of noise immunity and online user-configurable settings. RoSco digitally transmits entire neural waveforms for 14 of 16 channels at 20 kHz with 8-bit encoding which are streamed to the PC as standard USB audio packets. Up to 31 RoSco wireless modules can coexist in the same environment on non-overlapping independent channels. The design has spatial diversity reception via two antennas, which makes wireless communication resilient to fading and obstacles. In comparison with most existing wireless systems, this system has online user-selectable independent gain control of each channel in 8 factors from 500 to 32,000 times, two selectable ground references from a subset of channels, selectable channel grounding to disable noisy electrodes, and selectable bandwidth suitable for action potentials (300 Hz-3 kHz and low frequency field potentials (4 Hz-3 kHz. Indoor and outdoor recordings taken from freely behaving rodents are shown to be comparable to a commercial wired system in sorting for neural populations. The module has low input referred noise, battery life of 1.5 hours and transmission losses of 0.1% up to a range of 10 m.

  5. Miniature radioactive light source

    International Nuclear Information System (INIS)

    Caffarella, T.E.; Radda, G.J.; Dooley, H.H.

    1980-01-01

    A miniature radioactive light source for illuminating digital watches is described consisting of a glass tube with improved laser sealing and strength containing tritium gas and a transducer responsive to the gas. (U.K.)

  6. On-Demand Telemetry

    Data.gov (United States)

    National Aeronautics and Space Administration — AFRC has previously investigated the use of Network Based Telemetry. We will be building on that research to enable On-Demand Telemetry. On-Demand Telemetry is a way...

  7. Telemetry Standards

    National Research Council Canada - National Science Library

    1999-01-01

    The Telemetry Group has prepared this document to foster the compatibility of telemetry transmitting, receiving, and signal processing equipment at the member ranges under the cognizance of the RCC...

  8. A Miniature Recording Cardiotachometer

    DEFF Research Database (Denmark)

    Zsombor-Murray, Paul J; Vroomen, Louis J.; Hendriksen, Nils Thedin

    1981-01-01

    The design of a miniature, recording cardiotachometer is described. It is simple and can store digital data. Bench and field tests, using a hand-held display, are presented. Construction and principles of operation are discussed. Applications, with performing athlete subjects, are outlined....

  9. A low-power bidirectional telemetry device with a near-field charging feature for a cardiac microstimulator.

    Science.gov (United States)

    Shuenn-Yuh Lee; Chih-Jen Cheng; Ming-Chun Liang

    2011-08-01

    In this paper, wireless telemetry using the near-field coupling technique with round-wire coils for an implanted cardiac microstimulator is presented. The proposed system possesses an external powering amplifier and an internal bidirectional microstimulator. The energy of the microstimulator is provided by a rectifier that can efficiently charge a rechargeable device. A fully integrated regulator and a charge pump circuit are included to generate a stable, low-voltage, and high-potential supply voltage, respectively. A miniature digital processor includes a phase-shift-keying (PSK) demodulator to decode the transmission data and a self-protective system controller to operate the entire system. To acquire the cardiac signal, a low-voltage and low-power monitoring analog front end (MAFE) performs immediate threshold detection and data conversion. In addition, the pacing circuit, which consists of a pulse generator (PG) and its digital-to-analog (D/A) controller, is responsible for stimulating heart tissue. The chip was fabricated by Taiwan Semiconductor Manufacturing Company (TSMC) with 0.35-μm complementary metal-oxide semiconductor technology to perform the monitoring and pacing functions with inductively powered communication. Using a model with lead and heart tissue on measurement, a -5-V pulse at a stimulating frequency of 60 beats per minute (bpm) is delivered while only consuming 31.5 μW of power.

  10. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Chapter 3, July 2017 3-5 Table 3-4. Constant-Bandwidth FM Subcarrier Channels Frequency Criteria\\Channels: A B C D E F G H Deviation ...Telemetry Standards , RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms...Frequency Division Multiplexing Telemetry Standards ................................ 3-1 3.1 General

  11. A Comparison of Methods for Player Clustering via Behavioral Telemetry

    DEFF Research Database (Denmark)

    Drachen, Anders; Thurau, C.; Sifa, R.

    2013-01-01

    patterns in the behavioral data, and developing profiles that are actionable to game developers. There are numerous methods for unsupervised clustering of user behavior, e.g. k-means/c-means, Nonnegative Matrix Factorization, or Principal Component Analysis. Although all yield behavior categorizations......, interpretation of the resulting categories in terms of actual play behavior can be difficult if not impossible. In this paper, a range of unsupervised techniques are applied together with Archetypal Analysis to develop behavioral clusters from playtime data of 70,014 World of Warcraft players, covering a five......The analysis of user behavior in digital games has been aided by the introduction of user telemetry in game development, which provides unprecedented access to quantitative data on user behavior from the installed game clients of the entire population of players. Player behavior telemetry datasets...

  12. Miniaturized multiwavelength digital holography sensor for extensive in-machine tool measurement

    Science.gov (United States)

    Seyler, Tobias; Fratz, Markus; Beckmann, Tobias; Bertz, Alexander; Carl, Daniel

    2017-06-01

    In this paper we present a miniaturized digital holographic sensor (HoloCut) for operation inside a machine tool. With state-of-the-art 3D measurement systems, short-range structures such as tool marks cannot be resolved inside a machine tool chamber. Up to now, measurements had to be conducted outside the machine tool and thus processing data are generated offline. The sensor presented here uses digital multiwavelength holography to get 3D-shape-information of the machined sample. By using three wavelengths, we get a large artificial wavelength with a large unambiguous measurement range of 0.5mm and achieve micron repeatability even in the presence of laser speckles on rough surfaces. In addition, a digital refocusing algorithm based on phase noise is implemented to extend the measurement range beyond the limits of the artificial wavelength and geometrical depth-of-focus. With complex wave field propagation, the focus plane can be shifted after the camera images have been taken and a sharp image with extended depth of focus is constructed consequently. With 20mm x 20mm field of view the sensor enables measurement of both macro- and micro-structure (such as tool marks) with an axial resolution of 1 µm, lateral resolution of 7 µm and consequently allows processing data to be generated online which in turn qualifies it as a machine tool control. To make HoloCut compact enough for operation inside a machining center, the beams are arranged in two planes: The beams are split into reference beam and object beam in the bottom plane and combined onto the camera in the top plane later on. Using a mechanical standard interface according to DIN 69893 and having a very compact size of 235mm x 140mm x 215mm (WxHxD) and a weight of 7.5 kg, HoloCut can be easily integrated into different machine tools and extends no more in height than a typical processing tool.

  13. Design and analysis of miniature tri-axial fluxgate magnetometer

    Science.gov (United States)

    Zhi, Menghui; Tang, Liang; Qiao, Donghai

    2017-02-01

    The detection technology of weak magnetic field is widely used in Earth resource survey and geomagnetic navigation. Useful magnetic field information can be obtained by processing and analyzing the measurement data from magnetic sensors. A miniature tri-axial fluxgate magnetometer is proposed in this paper. This miniature tri-axial fluxgate magnetometer with ring-core structure has a dynamic range of the Earth’s field ±65,000 nT, resolution of several nT. It has three independent parts placed in three perpendicular planes for measuring three orthogonal magnetic field components, respectively. A field-programmable gate array (FPGA) is used to generate stimulation signal, analog-to-digital (A/D) convertor control signal, and feedback digital-to-analog (D/A) control signal. Design and analysis details are given to improve the dynamic range, sensitivity, resolution, and linearity. Our prototype was measured and compared with a commercial standard Magson fluxgate magnetometer as a reference. The results show that our miniature fluxgate magnetometer can follow the Magson’s change trend well. When used as a magnetic compass, our prototype only has ± 0.3∘ deviation compared with standard magnetic compass.

  14. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  15. High performance VLSI telemetry data systems

    Science.gov (United States)

    Chesney, J.; Speciale, N.; Horner, W.; Sabia, S.

    1990-01-01

    NASA's deployment of major space complexes such as Space Station Freedom (SSF) and the Earth Observing System (EOS) will demand increased functionality and performance from ground based telemetry acquisition systems well above current system capabilities. Adaptation of space telemetry data transport and processing standards such as those specified by the Consultative Committee for Space Data Systems (CCSDS) standards and those required for commercial ground distribution of telemetry data, will drive these functional and performance requirements. In addition, budget limitations will force the requirement for higher modularity, flexibility, and interchangeability at lower cost in new ground telemetry data system elements. At NASA's Goddard Space Flight Center (GSFC), the design and development of generic ground telemetry data system elements, over the last five years, has resulted in significant solutions to these problems. This solution, referred to as the functional components approach includes both hardware and software components ready for end user application. The hardware functional components consist of modern data flow architectures utilizing Application Specific Integrated Circuits (ASIC's) developed specifically to support NASA's telemetry data systems needs and designed to meet a range of data rate requirements up to 300 Mbps. Real-time operating system software components support both embedded local software intelligence, and overall system control, status, processing, and interface requirements. These components, hardware and software, form the superstructure upon which project specific elements are added to complete a telemetry ground data system installation. This paper describes the functional components approach, some specific component examples, and a project example of the evolution from VLSI component, to basic board level functional component, to integrated telemetry data system.

  16. XTCE. XML Telemetry and Command Exchange Tutorial

    Science.gov (United States)

    Rice, Kevin; Kizzort, Brad; Simon, Jerry

    2010-01-01

    An XML Telemetry Command Exchange (XTCE) tutoral oriented towards packets or minor frames is shown. The contents include: 1) The Basics; 2) Describing Telemetry; 3) Describing the Telemetry Format; 4) Commanding; 5) Forgotten Elements; 6) Implementing XTCE; and 7) GovSat.

  17. Miniature, mobile X-ray computed radiography system

    Science.gov (United States)

    Watson, Scott A; Rose, Evan A

    2017-03-07

    A miniature, portable x-ray system may be configured to scan images stored on a phosphor. A flash circuit may be configured to project red light onto a phosphor and receive blue light from the phosphor. A digital monochrome camera may be configured to receive the blue light to capture an article near the phosphor.

  18. Microcontroller-based underwater acoustic ECG telemetry system.

    Science.gov (United States)

    Istepanian, R S; Woodward, B

    1997-06-01

    This paper presents a microcontroller-based underwater acoustic telemetry system for digital transmission of the electrocardiogram (ECG). The system is designed for the real time, through-water transmission of data representing any parameter, and it was used initially for transmitting in multiplexed format the heart rate, breathing rate and depth of a diver using self-contained underwater breathing apparatus (SCUBA). Here, it is used to monitor cardiovascular reflexes during diving and swimming. The programmable capability of the system provides an effective solution to the problem of transmitting data in the presence of multipath interference. An important feature of the paper is a comparative performance analysis of two encoding methods, Pulse Code Modulation (PCM) and Pulse Position Modulation (PPM).

  19. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2001-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  20. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2003-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  1. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2002-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  2. Systems For Telemetry And Telecontrol - Practical Applications

    International Nuclear Information System (INIS)

    Stankovski, Mile J.; Kolemishevska-Gugulovska, Tatjana; Stanojkovski, Ratko

    2003-01-01

    This paper present practical aspects in application of telemetry and tele control using new aspect of electronics, signal processing, telecommunications, and of course theory of control systems. In the paper some aspects during the design of telemetry and tele control systems are presented. Also it is presented one real system of telemetry and tele control in water distribution, level measurement in four tanks on the different locations. (Author)

  3. Test Telemetry And Command System (TTACS)

    Science.gov (United States)

    Fogel, Alvin J.

    1994-01-01

    The Jet Propulsion Laboratory has developed a multimission Test Telemetry and Command System (TTACS) which provides a multimission telemetry and command data system in a spacecraft test environment. TTACS reuses, in the spacecraft test environment, components of the same data system used for flight operations; no new software is developed for the spacecraft test environment. Additionally, the TTACS is transportable to any spacecraft test site, including the launch site. The TTACS is currently operational in the Galileo spacecraft testbed; it is also being provided to support the Cassini and Mars Surveyor Program projects. Minimal personnel data system training is required in the transition from pre-launch spacecraft test to post-launch flight operations since test personnel are already familiar with the data system's operation. Additionally, data system components, e.g. data display, can be reused to support spacecraft software development; and the same data system components will again be reused during the spacecraft integration and system test phases. TTACS usage also results in early availability of spacecraft data to data system development and, as a result, early data system development feedback to spacecraft system developers. The TTACS consists of a multimission spacecraft support equipment interface and components of the multimission telemetry and command software adapted for a specific project. The TTACS interfaces to the spacecraft, e.g., Command Data System (CDS), support equipment. The TTACS telemetry interface to the CDS support equipment performs serial (RS-422)-to-ethernet conversion at rates between 1 bps and 1 mbps, telemetry data blocking and header generation, guaranteed data transmission to the telemetry data system, and graphical downlink routing summary and control. The TTACS command interface to the CDS support equipment is nominally a command file transferred in non-real-time via ethernet. The CDS support equipment is responsible for

  4. 106-17 Telemetry Standards Chapter 1

    Science.gov (United States)

    2017-07-01

    Telemetry Standards, RCC Standard 106-17 Chapter 1, July 2017 1-1 CHAPTER 1 Introduction The Telemetry Standards address the here-to-date...for Federal Radio Frequency Management . Copies of that manual may be obtained from: Executive Secretary, Interdepartmental Radio Advisory Committee

  5. ZigBee-Based Telemetry System

    Directory of Open Access Journals (Sweden)

    L. Khriji

    2010-12-01

    Full Text Available Nowadays, there is a significant improvement in technology regarding healthcare. Real-time monitoring systems improve the quality of life of patients as well as the performance of hospitals and healthcare centers. In this paper, we present an implementation of a designed framework of a telemetry system using ZigBee technology for automatic and real-time monitoring of Biomedical signals. These signals are collected and processed using 2-tiered subsystems. The first subsystem is the mobile device which is carried on the body and runs a number of biosensors. The second subsystem performs further processing by a local base station using the raw data which is transmitted on-request by the mobile device. The processed data as well as its analysis are then continuously monitored and diagnosed through a human-machine interface. The system should possess low power consumption, low cost and advanced configuration possibilities. This paper accelerates the digital convergence age through continual research and development of technologies related to healthcare.

  6. 3D Display of Spacecraft Dynamics Using Real Telemetry

    Directory of Open Access Journals (Sweden)

    Sanguk Lee

    2002-12-01

    Full Text Available 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

  7. Miniature digital radiacmeter

    International Nuclear Information System (INIS)

    Raymond, D.; Nirschl, J.

    1978-01-01

    A prototype instrument for monitoring radiation levels has been developed under contract to U.S. Army Electronics Research and Development Command, Fort Monmouth, N.J., for technical evaluation. This instrument measures gamma dose-rates from 10 mrad/h to 1000 rad/h using a small pressurized ion chamber, which contains a hybrid integrated circuit current-to-frequency converter. The autoranging digital readout uses a liquid crystal display. Audible and visual alarm are incorporated, to alert the operator when a preset level of dose-rate has been exceeded. A non-volatile total dose memory can be read on command. Control of the instrument is via a sealed front panel keyboard. Battery life exceeds 100 hours continuous operation between recharging. The instrument also includes provisions for a plug-in Geiger-Mueller probe that extends the sensitivity to .01 mrad/h for use as a frisking probe. Both detectors are designed to be sensitive to beta radiation as well as gamma. Data is presented on the evaluation to date of the performance of the prototype instrument over a wide range of temperature and dose-rate

  8. A history of telemetry in fishery research: Chapter 2

    Science.gov (United States)

    Hockersmith, Eric; Beeman, John W.; Adams, Noah S.; Beeman, John W.; Eiler, John H.

    2012-01-01

    Telemetry provides a powerful and flexible tool for studying fish and other aquatic animals, and its use has become increasingly commonplace. However, telemetry is gear intensive and typically requires more specialized knowledge and training than many other field techniques. As with other scientific methods, collecting good data is dependent on an understanding of the underlying principles behind the approach, knowing how to use the equipment and techniques properly, and recognizing what to do with the data collected. This book provides a road map for using telemetry to study aquatic animals, and provides the basic information needed to plan, implement, and conduct a telemetry study under field conditions. Topics include acoustic or radio telemetry study design, tag implantation techniques, radio and acoustic telemetry principles and case studies, and data management and analysis.

  9. Telemetry Standards

    Science.gov (United States)

    2017-07-01

    contractor facilities. The goal of frequency management is to encourage maximal use and minimal interference among telemetry users and between...difference in path lengths between the direct and reflected signals. This depends on the horizontal distance d, the altitude of the aircraft ht , and

  10. 47 CFR 90.238 - Telemetry operations.

    Science.gov (United States)

    2010-10-01

    ... MHz band (as available in the Public Safety Pool for bio-medical telemetry operations). (i) For... with § 90.257 and subject to the rules governing the use of that band). (b) 154.45625, 154.46375, 154...-470 MHz band, telemetry operations will be authorized on a secondary basis with a transmitter output...

  11. Home Video Telemetry vs inpatient telemetry: A comparative study looking at video quality

    Directory of Open Access Journals (Sweden)

    Sutapa Biswas

    Full Text Available Objective: To compare the quality of home video recording with inpatient telemetry (IPT to evaluate our current Home Video Telemetry (HVT practice. Method: To assess our HVT practice, a retrospective comparison of the video quality against IPT was conducted with the latter as the gold standard. A pilot study had been conducted in 2008 on 5 patients.Patients (n = 28 were included in each group over a period of one year.The data was collected from referral spreadsheets, King’s EPR and telemetry archive.Scoring of the events captured was by consensus using two scorers.The variables compared included: visibility of the body part of interest, visibility of eyes, time of event, illumination, contrast, sound quality and picture clarity when amplified to 200%.Statistical evaluation was carried out using Shapiro–Wilk and Chi-square tests. The P-value of ⩽0.05 was considered statistically significant. Results: Significant differences were demonstrated in lighting and contrast between the two groups (HVT performed better in both.Amplified picture quality was slightly better in the HVT group. Conclusion: Video quality of HVT is comparable to IPT, even surpassing IPT in certain aspects such as the level of illumination and contrast. Results were reconfirmed in a larger sample of patients with more variables. Significance: Despite the user and environmental variability in HVT, it looks promising and can be seriously considered as a preferable alternative for patients who may require investigation at locations remote from an EEG laboratory. Keywords: Home Video Telemetry, EEG, Home video monitoring, Video quality

  12. Micro and nano lasers for digital photonics

    NARCIS (Netherlands)

    Hill, M.T.; Oei, Y.S.; Zhu, Y.C.; Smit, M.K.

    2007-01-01

    The small size, low-power and high-speed of nano-lasers make them an attractive nonlinear element for digital photonics. Further miniaturization of lasers below the diffraction limit is required before digital photonics can compete with electronics.

  13. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  14. Miniaturized star tracker for micro spacecraft with high angular rate

    Science.gov (United States)

    Li, Jianhua; Li, Zhifeng; Niu, Zhenhong; Liu, Jiaqi

    2017-10-01

    There is a clear need for miniaturized, lightweight, accurate and inexpensive star tracker for spacecraft with large anglar rate. To face these new constraints, the Beijing Institute of Space Long March Vehicle has designed, built and flown a low cost miniaturized star tracker that provides autonomous ("Lost in Space") inertial attitude determination, 2 Hz 3-axis star tracking, and digital imaging with embedded compression. Detector with high sensitivity is adopted to meet the dynamic and miniature requirement. A Sun and Moon avoiding method based on the calculation of Sun and Moon's vector by astronomical theory is proposed. The produced prototype weight 0.84kg, and can be used for a spacecraft with 6°/s anglar rate. The average angle measure error is less than 43 arc second. The ground verification and application of the star tracker during the pick-up flight test showed that the capability of the product meet the requirement.

  15. Group telemetry analysis using the World Wide Web

    Energy Technology Data Exchange (ETDEWEB)

    Kalibjian, J.

    1996-12-31

    Today it is not uncommon to have large contractor teams involved in the design and deployment of even small satellite systems. The larger (and more geographically remote) the team members, the more difficult it becomes to efficiently manage the disbursement of telemetry data for evaluation and analysis. Further complications are introduced if some of the telemetry data is sensitive. An application is described which can facilitate telemetry data sharing utilizing the National Information Infrastructure (Internet).

  16. Review of research methodologies for tigers: telemetry.

    Science.gov (United States)

    Miller, Clayton S; Hebblewhite, Mark; Goodrich, John M; Miquelle, Dale G

    2010-12-01

    Over the past half century, wildlife research has relied on technological advances to gain additional insight into the secretive lives of animals. This revolution started in the 1960s with the development of radio telemetry and continues today with the use of Global Positioning System (GPS)-based research techniques. In the present paper we review the history of radio telemetry from its origins with grizzly bears in Yellowstone to its early applications in tiger research and conservation in Asia. We address the different types of data that are available using radio telemetry as opposed to using other research techniques, such as behavioral observations, camera trapping, DNA analysis and scat analysis. In the late 1990s, the rapid development of GPS collar technology revolutionized wildlife research. This new technology has enabled researchers to dramatically improve their ability to gather data on animal movements and ecology. Despite the ecological and conservation benefits of radio telemetry, there have been few telemetry studies of tigers in the wild, and most have been on the Bengal or Amur subspecies. We close with an assessment of the current tiger conservation efforts using GPS technology and discuss how this new information can help to preserve tigers for future generations. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  17. LP MOON MERGED TELEMETRY DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Prospector merged telemetry data set is a result of comparing the two Lunar Prospector telemetry data streams and selecting one of them. The Lunar...

  18. Guideline-based intervention to reduce telemetry rates in a large tertiary centre.

    Science.gov (United States)

    Ramkumar, Satish; Tsoi, Edward H; Raghunath, Ajay; Dias, Floyd F; Li Wai Suen, Christopher; Tsoi, Andrew H; Mansfield, Darren R

    2017-07-01

    Inappropriate cardiac telemetry use is associated with reduced patient flow and increased healthcare costs. To evaluate the outcomes of guideline-based application of cardiac telemetry. Phase I involved a prospective audit (March to August 2011) of telemetry use at a tertiary hospital. Data were collected on indication for telemetry and clinical outcomes. Phase II prospectively included patients more than 18 years under general medicine requiring ward-based telemetry. As phase II occurred at a time remotely from phase I, an audit similar to phase I (phase II - baseline) was completed prior to a 3-month intervention (May to August 2015). The intervention consisted of a daily telemetry ward round and an admission form based on the American Heart Association guidelines (class I, telemetry indicated; class II, telemetry maybe indicated; class III, telemetry not indicated). Patient demographics, telemetry data, and clinical outcomes were studied. Primary endpoint was the percentage reduction of class III indications, while secondary endpoint included telemetry duration. In phase I (n = 200), 38% were admitted with a class III indication resulting in no change in clinical management. A total of 74 patients was included in phase II baseline (mean ± standard deviation (SD) age 73 years ± 14.9, 57% male), whilst 65 patients were included in the intervention (mean ± SD age 71 years ± 18.4, 35% male). Both groups had similar baseline characteristics. There was a reduction in class III admissions post-intervention from 38% to 11%, P 0.05). Guideline-based telemetry admissions and a regular telemetry ward round are associated with a reduction in inappropriate telemetry use. © 2017 Royal Australasian College of Physicians.

  19. Smart Sensors for Launch Vehicles

    Science.gov (United States)

    Ray, Sabooj; Mathews, Sheeja; Abraham, Sheena; Pradeep, N.; Vinod, P.

    2017-12-01

    Smart Sensors bring a paradigm shift in the data acquisition mechanism adopted for launch vehicle telemetry system. The sensors integrate signal conditioners, digitizers and communication systems to give digital output from the measurement location. Multiple sensors communicate with a centralized node over a common digital data bus. An in-built microcontroller gives the sensor embedded intelligence to carry out corrective action for sensor inaccuracies. A smart pressure sensor has been realized and flight-proven to increase the reliability as well as simplicity in integration so as to obtain improved data output. Miniaturization is achieved by innovative packaging. This work discusses the construction, working and flight performance of such a sensor.

  20. Acoustic telemetry and fisheries management

    Science.gov (United States)

    Crossin, Glenn T.; Heupel, Michelle R.; Holbrook, Christopher; Hussey, Nigel E.; Lowerre-Barbieri, Susan K.; Nguyen, Vivian M.; Raby, Graham D.; Cooke, Steven J.

    2017-01-01

    This paper reviews the use of acoustic telemetry as a tool for addressing issues in fisheries management, and serves as the lead to the special Feature Issue of Ecological Applications titled “Acoustic Telemetry and Fisheries Management”. Specifically, we provide an overview of the ways in which acoustic telemetry can be used to inform issues central to the ecology, conservation, and management of exploited and/or imperiled fish species. Despite great strides in this area in recent years, there are comparatively few examples where data have been applied directly to influence fisheries management and policy. We review the literature on this issue, identify the strengths and weaknesses of work done to date, and highlight knowledge gaps and difficulties in applying empirical fish telemetry studies to fisheries policy and practice. We then highlight the key areas of management and policy addressed, as well as the challenges that needed to be overcome to do this. We conclude with a set of recommendations about how researchers can, in consultation with stock assessment scientists and managers, formulate testable scientific questions to address and design future studies to generate data that can be used in a meaningful way by fisheries management and conservation practitioners. We also urge the involvement of relevant stakeholders (managers, fishers, conservation societies, etc.) early on in the process (i.e. in the co-creation of research projects), so that all priority questions and issues can be addressed effectively.

  1. An Advanced Commanding and Telemetry System

    Science.gov (United States)

    Hill, Maxwell G. G.

    The Loral Instrumentation System 500 configured as an Advanced Commanding and Telemetry System (ACTS) supports the acquisition of multiple telemetry downlink streams, and simultaneously supports multiple uplink command streams for today's satellite vehicles. By using industry and federal standards, the system is able to support, without relying on a host computer, a true distributed dataflow architecture that is complemented by state-of-the-art RISC-based workstations and file servers.

  2. Telemetry System of Biological Parameters

    Directory of Open Access Journals (Sweden)

    Jan Spisak

    2005-01-01

    Full Text Available The mobile telemetry system of biological parameters serves for reading and wireless data transfer of measured values of selected biological parameters to an outlying computer. It concerns basically long time monitoring of vital function of car pilot.The goal of this projects is to propose mobile telemetry system for reading, wireless transfer and processing of biological parameters of car pilot during physical and psychical stress. It has to be made with respect to minimal consumption, weight and maximal device mobility. This system has to eliminate signal noise, which is created by biological artifacts and disturbances during the data transfer.

  3. Atlantic Salmon Telemetry Monitoring

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Annual telemetry data are collected as part of specific projects (assessments within watersheds) or as opportunistic efforts to characterize Atlantic salmon smolt...

  4. An Enhanced Run-Length Encoding Compression Method for Telemetry Data

    Directory of Open Access Journals (Sweden)

    Shan Yanhu

    2017-09-01

    Full Text Available The telemetry data are essential in evaluating the performance of aircraft and diagnosing its failures. This work combines the oversampling technology with the run-length encoding compression algorithm with an error factor to further enhance the compression performance of telemetry data in a multichannel acquisition system. Compression of telemetry data is carried out with the use of FPGAs. In the experiments there are used pulse signals and vibration signals. The proposed method is compared with two existing methods. The experimental results indicate that the compression ratio, precision, and distortion degree of the telemetry data are improved significantly compared with those obtained by the existing methods. The implementation and measurement of the proposed telemetry data compression method show its effectiveness when used in a high-precision high-capacity multichannel acquisition system.

  5. Challenges and prospects in the telemetry of insects

    NARCIS (Netherlands)

    Kissling, W.D.; Pattemore, D.E.; Hagen, M.

    2014-01-01

    Radio telemetry has been widely used to study the space use and movement behaviour of vertebrates, but transmitter sizes have only recently become small enough to allow tracking of insects under natural field conditions. Here, we review the available literature on insect telemetry using active

  6. 30 pJ/b, 67 Mbps, Centimeter-to-Meter Range Data Telemetry With an IR-UWB Wireless Link.

    Science.gov (United States)

    Ebrazeh, Ali; Mohseni, Pedram

    2015-06-01

    This paper reports an energy-efficient, impulse radio ultra wideband (IR-UWB) wireless link operating in 3-5 GHz for data telemetry over centimeter-to-meter range distances at rates extended to tens of Mbps. The link comprises an all-digital, integrated transmitter (TX) fabricated in 90 nm 1P/9M CMOS that incorporates a waveform-synthesis pulse generator and a timing generator for on-off-keying (OOK) pulse modulation and phase scrambling. The link also incorporates an energy-detection receiver (RX) realized with commercial off-the-shelf (COTS) components that performs radio-frequency (RF) filtering, amplification, logarithmic power detection for data demodulation and automatic level control for robust operation in the presence of distance variations. Employing a miniaturized, UWB, chip antenna for the TX and RX, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 50 Mbps over 10 cm-1 m is shown. Further, employing a high-gain horn antenna for the RX, wireless transmission of PRBS data at rates up to 67 Mbps over 50 cm-4 m is shown with a TX energy consumption of 30 pJ/b (i.e., power consumption of 2 mW) from 1.2 V. The measured bit error rate (BER) in both cases is wireless recording of the background current of a carbon-fiber microelectrode (CFM) in one fast-scan cyclic voltammetry (FSCV) scan using the IR-UWB link are also included, exhibiting excellent match with those obtained from a conventional frequency-shift-keyed (FSK) link at ~433 MHz.

  7. High-Performance Wireless Telemetry

    Science.gov (United States)

    Griebeler, Elmer; Nawash, Nuha; Buckley, James

    2011-01-01

    Prior technology for machinery data acquisition used slip rings, FM radio communication, or non-real-time digital communication. Slip rings are often noisy, require much space that may not be available, and require access to the shaft, which may not be possible. FM radio is not accurate or stable, and is limited in the number of channels, often with channel crosstalk, and intermittent as the shaft rotates. Non-real-time digital communication is very popular, but complex, with long development time, and objections from users who need continuous waveforms from many channels. This innovation extends the amount of information conveyed from a rotating machine to a data acquisition system while keeping the development time short and keeping the rotating electronics simple, compact, stable, and rugged. The data are all real time. The product of the number of channels, times the bit resolution, times the update rate, gives a data rate higher than available by older methods. The telemetry system consists of a data-receiving rack that supplies magnetically coupled power to a rotating instrument amplifier ring in the machine being monitored. The ring digitizes the data and magnetically couples the data back to the rack, where it is made available. The transformer is generally a ring positioned around the axis of rotation with one side of the transformer free to rotate and the other side held stationary. The windings are laid in the ring; this gives the data immunity to any rotation that may occur. A medium-frequency sine-wave power source in a rack supplies power through a cable to a rotating ring transformer that passes the power on to a rotating set of electronics. The electronics power a set of up to 40 sensors and provides instrument amplifiers for the sensors. The outputs from the amplifiers are filtered and multiplexed into a serial ADC. The output from the ADC is connected to another rotating ring transformer that conveys the serial data from the rotating section to

  8. Comprehension of Spacecraft Telemetry Using Hierarchical Specifications of Behavior

    Science.gov (United States)

    Havelund, Klaus; Joshi, Rajeev

    2014-01-01

    A key challenge in operating remote spacecraft is that ground operators must rely on the limited visibility available through spacecraft telemetry in order to assess spacecraft health and operational status. We describe a tool for processing spacecraft telemetry that allows ground operators to impose structure on received telemetry in order to achieve a better comprehension of system state. A key element of our approach is the design of a domain-specific language that allows operators to express models of expected system behavior using partial specifications. The language allows behavior specifications with data fields, similar to other recent runtime verification systems. What is notable about our approach is the ability to develop hierarchical specifications of behavior. The language is implemented as an internal DSL in the Scala programming language that synthesizes rules from patterns of specification behavior. The rules are automatically applied to received telemetry and the inferred behaviors are available to ground operators using a visualization interface that makes it easier to understand and track spacecraft state. We describe initial results from applying our tool to telemetry received from the Curiosity rover currently roving the surface of Mars, where the visualizations are being used to trend subsystem behaviors, in order to identify potential problems before they happen. However, the technology is completely general and can be applied to any system that generates telemetry such as event logs.

  9. Automatic Satellite Telemetry Analysis for SSA using Artificial Intelligence Techniques

    Science.gov (United States)

    Stottler, R.; Mao, J.

    In April 2016, General Hyten, commander of Air Force Space Command, announced the Space Enterprise Vision (SEV) (http://www.af.mil/News/Article-Display/Article/719941/hyten-announces-space-enterprise-vision/). The SEV addresses increasing threats to space-related systems. The vision includes an integrated approach across all mission areas (communications, positioning, navigation and timing, missile warning, and weather data) and emphasizes improved access to data across the entire enterprise and the ability to protect space-related assets and capabilities. "The future space enterprise will maintain our nation's ability to deliver critical space effects throughout all phases of conflict," Hyten said. Satellite telemetry is going to become available to a new audience. While that telemetry information should be valuable for achieving Space Situational Awareness (SSA), these new satellite telemetry data consumers will not know how to utilize it. We were tasked with applying AI techniques to build an infrastructure to process satellite telemetry into higher abstraction level symbolic space situational awareness and to initially populate that infrastructure with useful data analysis methods. We are working with two organizations, Montana State University (MSU) and the Air Force Academy, both of whom control satellites and therefore currently analyze satellite telemetry to assess the health and circumstances of their satellites. The design which has resulted from our knowledge elicitation and cognitive task analysis is a hybrid approach which combines symbolic processing techniques of Case-Based Reasoning (CBR) and Behavior Transition Networks (BTNs) with current Machine Learning approaches. BTNs are used to represent the process and associated formulas to check telemetry values against anticipated problems and issues. CBR is used to represent and retrieve BTNs that represent an investigative process that should be applied to the telemetry in certain circumstances

  10. Animal Telemetry Network (ATN)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data (updated daily) are from the Animal Telemetry Network (ATN) program. Begun as one of the field projects in the international Census of Marine Life, the...

  11. XTCE: XML Telemetry and Command Exchange Tutorial, XTCE Version 1

    Science.gov (United States)

    Rice, Kevin; Kizzort, Brad

    2008-01-01

    These presentation slides are a tutorial on XML Telemetry and Command Exchange (XTCE). The goal of XTCE is to provide an industry standard mechanism for describing telemetry and command streams (particularly from satellites.) it wiill lower cost and increase validation over traditional formats, and support exchange or native format.XCTE is designed to describe bit streams, that are typical of telemetry and command in the historic space domain.

  12. Northern Pintail Telemetry [ds231

    Data.gov (United States)

    California Natural Resource Agency — Using radio-telemetry, female northern pintail (Anas acuta) survival, distribution, and movements during late August-March in Central California were determined...

  13. Uniform LED illuminator for miniature displays

    Science.gov (United States)

    Medvedev, Vladimir; Pelka, David G.; Parkyn, William A.

    1998-10-01

    The Total Internally Reflecting (TIR) lens is a faceted structure composed of prismatic elements that collect a source's light over a much larger angular range than a conventional Fresnel lens. It has been successfully applied to the efficient collimation of light from incandescent and fluorescent lamps, and from light-emitting diodes (LEDs). A novel LED-powered collimating backlight is presented here, for uniformly illuminating 0.25'-diagonal miniature liquid- crystal displays, which are a burgeoning market for pagers, cellular phones, digital cameras, camcorders, and virtual- reality displays. The backlight lens consists of a central dual-asphere refracting section and an outer TIR section, properly curved with a curved exit face.

  14. Demodulation of acoustic telemetry binary phase shift keying signal based on high-order Duffing system

    International Nuclear Information System (INIS)

    Yan Bing-Nan; Liu Chong-Xin; Ni Jun-Kang; Zhao Liang

    2016-01-01

    In order to grasp the downhole situation immediately, logging while drilling (LWD) technology is adopted. One of the LWD technologies, called acoustic telemetry, can be successfully applied to modern drilling. It is critical for acoustic telemetry technology that the signal is successfully transmitted to the ground. In this paper, binary phase shift keying (BPSK) is used to modulate carrier waves for the transmission and a new BPSK demodulation scheme based on Duffing chaos is investigated. Firstly, a high-order system is given in order to enhance the signal detection capability and it is realized through building a virtual circuit using an electronic workbench (EWB). Secondly, a new BPSK demodulation scheme is proposed based on the intermittent chaos phenomena of the new Duffing system. Finally, a system variable crossing zero-point equidistance method is proposed to obtain the phase difference between the system and the BPSK signal. Then it is determined that the digital signal transmitted from the bottom of the well is ‘0’ or ‘1’. The simulation results show that the demodulation method is feasible. (paper)

  15. A Web-Based Airborne Remote Sensing Telemetry Server, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A Web-based Airborne Remote Sensing Telemetry Server (WARSTS) is proposed to integrate UAV telemetry and web-technology into an innovative communication, command,...

  16. RF Front End Based on MEMS Components for Miniaturized Digital EVA Radio, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this SBIR project, AlphaSense, Inc. and the Carnegie Mellon University propose to develop a RF receiver front end based on CMOS-MEMS components for miniaturized...

  17. Using Onboard Telemetry for MAVEN Orbit Determination

    Science.gov (United States)

    Lam, Try; Trawny, Nikolas; Lee, Clifford

    2013-01-01

    Determination of the spacecraft state has been traditional done using radiometric tracking data before and after the atmosphere drag pass. This paper describes our approach and results to include onboard telemetry measurements in addition to radiometric observables to refine the reconstructed trajectory estimate for the Mars Atmosphere and Volatile Evolution Mission (MAVEN). Uncertainties in the Mars atmosphere models, combined with non-continuous tracking degrade navigation accuracy, making MAVEN a key candidate for using onboard telemetry data to help complement its orbit determination process.

  18. DEVELOPMENTAL STUDIES OF NUCLEAR DIGITAL TRANSDUCERS

    Energy Technology Data Exchange (ETDEWEB)

    Hyde, James L.

    1963-09-15

    A pressure transducer based on mechanical modulation of a beam of alpha particles is described. This type of transducer is capable of direct digital pressure measurexnent with corresponding telemetry advantages. Any variable that is sensed through a mechanical displacement is measurable by means of a corresponding member of this transducer family. Preliminary tests of an experimental pressure transducer show an overall accuracy within a few tenths of one percent, with promise of substantial improvement. General characteristics of nuclear digital transducers include exceptional long-term calibration stability and accuracy, independent of ambient environmental effects. Three concepts of systems enipioying these transducers are discussed. (auth)

  19. Precise timing correlation in telemetry recording and processing systems

    Science.gov (United States)

    Pickett, R. B.; Matthews, F. L.

    1973-01-01

    Independent PCM telemetry data signals received from missiles must be correlated to within + or - 100 microseconds for comparison with radar data. Tests have been conducted to determine RF antenna receiving system delays; delays associated with wideband analog tape recorders used in the recording, dubbing and repdocuing processes; and uncertainties associated with computer processed time tag data. Several methods used in the recording of timing are evaluated. Through the application of a special time tagging technique, the cumulative timing bias from all sources is determined and the bias removed from final data. Conclusions show that relative time differences in receiving, recording, playback and processing of two telemetry links can be accomplished with a + or - 4 microseconds accuracy. In addition, the absolute time tag error (with respect to UTC) can be reduced to less than 15 microseconds. This investigation is believed to be the first attempt to identify the individual error contributions within the telemetry system and to describe the methods of error reduction within the telemetry system and to describe the methods of error reduction and correction.

  20. Intermediate Frequency Digital Receiver Based on Multi-FPGA System

    Directory of Open Access Journals (Sweden)

    Chengchang Zhang

    2016-01-01

    Full Text Available Aiming at high-cost, large-size, and inflexibility problems of traditional analog intermediate frequency receiver in the aerospace telemetry, tracking, and command (TTC system, we have proposed a new intermediate frequency (IF digital receiver based on Multi-FPGA system in this paper. Digital beam forming (DBF is realized by coordinated rotation digital computer (CORDIC algorithm. An experimental prototype has been developed on a compact Multi-FPGA system with three FPGAs to receive 16 channels of IF digital signals. Our experimental results show that our proposed scheme is able to provide a great convenience for the design of IF digital receiver, which offers a valuable reference for real-time, low power, high density, and small size receiver design.

  1. Evaluation of a miniature electromagnetic position tracker

    International Nuclear Information System (INIS)

    Hummel, Johann; Figl, Michael; Kollmann, Christian; Bergmann, Helmar; Birkfellner, Wolfgang

    2002-01-01

    The advent of miniaturized electromagnetic digitizers opens a variety of potential clinical applications for computer aided interventions using flexible instruments; endoscopes or catheters can easily be tracked within the body. With respect to the new applications, the systematic distortions induced by various materials such as closed metallic loops, wire guides, catheters, and ultrasound scan heads were systematically evaluated in this paper for a new commercial tracking system. We employed the electromagnetic tracking system Aurora trade mark sign (Mednetix/CH, NDI/Can); data were acquired using the serial port of a PC running SuSE Linux 7.1 (SuSE, Gmbh, Nuernberg). Objects introduced into the digitizer volume included wire loops of different diameters, wire guides, optical tracking tools, an ultrasonic (US) scan head, an endoscope with radial ultrasound scan head and various other objects used in operating rooms and interventional suites. Beyond this, we determined the influence of a C-arm fluoroscopy unit. To quantify the reliability of the system, the miniaturized sensor was mounted on a nonmetallic measurement rack while the transmitter was fixed at three different distances within the digitizer range. The tracker was shown to be more sensitive to distortions caused by materials close to the emitter (average distortion error 13.6 mm±16.6 mm for wire loops positioned at a distance between 100 mm and 200 mm from the emitter). Distortions caused by materials near the sensor (distances smaller than 100 mm) are small (typical error 2.2 mm±1.9 mm). The C-arm fluoroscopy unit caused considerable distortions and limits the reliability of the tracker (distortion error 18.6 mm±24.9 mm). Distortions resulting from the US scan head are high at distances smaller than about 100 mm from the emitter. The distortions also increase when the scan head is positioned horizontally and close to the sensor (average error 4.1 mm±1.5 mm when the scan head is positioned within a

  2. Miniature multichannel analyzer for process monitoring

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.; Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.; Wiig, L.G.; Ianakiev, K.D.

    1993-01-01

    A new, 4,000-channel analyzer has been developed for gamma-ray spectroscopy applications. A design philosophy of hardware and software building blocks has been combined with design goals of simplicity, compactness, portability, and reliability. The result is a miniature, modular multichannel analyzer (MMMCA), which offers solution to a variety of nondestructive assay (NDA) needs in many areas of general application, independent of computer platform or operating system. Detector-signal analog electronics, the bias supply, and batteries are included in the virtually pocket-size, low-power MMMCA unit. The MMMCA features digital setup and control, automated data reduction, and automated quality assurance. Areas of current NDA applications include on-line continuous (process) monitoring, process material holdup measurements, and field inspections

  3. Holy grail: Pioneering acoustic telemetry technology set to revolutionize downhole communication

    Energy Technology Data Exchange (ETDEWEB)

    Greenaway, R.

    2003-12-01

    Acoustic telemetry, a faster and more efficient downhole-to-surface-communication technology, is the latest development in downhole communication systems. The system has been developed by Extreme Engineering Limited of Calgary, led by Derek Logan, founder and one-time senior vice-president of Ryan Energy Technologies that developed the original measurement -while-drilling (MWD) and logging-while-drilling )LWD) tools. The company predicts that acoustic telemetry will cause a massive transformation of the drilling industry in Western Canada once the technology is commercialized. Conventional MWD techniques, based on mud-pulse technology, have been industry standard since the 1970s, but mud-pulse technology is now considered extremely slow. In the 1980s industry came up electromagnetic telemetry, as an alternative to mud-pulse. Today, the need to transmit ever more data, the need for a faster communications system and greater wellbore control, has become even more pressing. Logan believes that acoustic technology is the answer. It is not only capable of transmitting data 20 to 30 times faster than mud-pulse telemetries, it can also communicate massive amounts of data. It can be used in drilling, completion production, drillstem testing, frac monitoring and any other wellbore process requiring wireless real-time telemetry. Acoustic telemetry is also the only wireless system that can perform MWD and LWD in offshore underbalanced drilling. Notwithstanding its great promise, Extreme Engineering Limited had considerable difficulty raising funds for developing and commercializing XAcT (the trade name for acoustic telemetry). Prospects are reported to have been substantially improved by recent infusion of funds by the federal Industrial Research Assistance Program (IRAP) , and XAcT's recognition by R and D Magazine with one of the R and D 100 awards for 2003. 3 figs.

  4. Toward a national animal telemetry network for aquatic observations in the United States

    Science.gov (United States)

    Block, Barbara A.; Holbrook, Christopher; Simmons, Samantha E; Holland, Kim N; Ault, Jerald S.; Costa, Daniel P.; Mate, Bruce R; Seitz, Andrew C.; Arendt, Michael D.; Payne, John; Mahmoudi, Behzad; Moore, Peter L.; Price, James; J. J. Levenson,; Wilson, Doug; Kochevar, Randall E

    2016-01-01

    Animal telemetry is the science of elucidating the movements and behavior of animals in relation to their environment or habitat. Here, we focus on telemetry of aquatic species (marine mammals, sharks, fish, sea birds and turtles) and so are concerned with animal movements and behavior as they move through and above the world’s oceans, coastal rivers, estuaries and great lakes. Animal telemetry devices (“tags”) yield detailed data regarding animal responses to the coupled ocean–atmosphere and physical environment through which they are moving. Animal telemetry has matured and we describe a developing US Animal Telemetry Network (ATN) observing system that monitors aquatic life on a range of temporal and spatial scales that will yield both short- and long-term benefits, fill oceanographic observing and knowledge gaps and advance many of the U.S. National Ocean Policy Priority Objectives. ATN has the potential to create a huge impact for the ocean observing activities undertaken by the U.S. Integrated Ocean Observing System (IOOS) and become a model for establishing additional national-level telemetry networks worldwide.

  5. The U.S. Animal Telemetry Network: A Plan for Implementation

    Science.gov (United States)

    Weise, M. J.; Simmons, S. E.

    2016-02-01

    The U.S. is a global leader in animal telemetry, with tremendous animal telemetry infrastructure and considerable technical expertise in telemetry operations. However, these research assets are often owned and operated independently by multiple agencies and institutions with limited to no connectivity. This prevents the scientific community from efficiently coordinating data and thereby best serving societal needs. In this talk we will describe how the U.S. Animal Telemetry Network (ATN), under the auspices of the U.S. Integrated Ocean Observing System (IOOS), will provide a mechanism to facilitate and empower an alliance among federal, industry, academic, state, local, tribal, and non-federal organizations. Animal telemetry technology is now considered mature and operational, and these observing data and products are ready to be integrated into the U.S. IOOS. The ATN data management approach involves receiving, handling, and distributing diverse data types from archival, satellite, and acoustic tag platforms that originate from a variety of individual researchers and large programs using consistent metadata standards and best practices. The core of the ATN data management system will be a quasi-centralized national ATN Data Assembly Center that will receive and distribute data and data products to U.S. IOOS RAs and other partner organizations. The integration of biological resources into ocean observation will address U.S. IOOS needs regarding societal benefits by, for example, aiming to improve predictions of climate change, to more effectively protect and restore healthy coastal ecosystems, and to enable the sustained use of ocean and coastal resources. We will describe the plan for how the ATN will maximize the benefit of existing investments by providing a mechanism for sustained operations and consistent delivery of animal telemetry data across the U.S. and in conjunction with international ocean observing systems.

  6. The Whole new world of miniature technology

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1980-07-01

    In the past ten years, miniaturization of both electrical and mechanical parts has significantly increased. Documentation of the design and production capabilities of miniaturization in the electronics industry is well-defined. Literature on the subject of miniaturization of metal piece parts, however, is hard to find. Some of the current capabilities in the manufacture of miniature metal piece parts or miniature features in larger piece parts are discussed.

  7. Animal movement constraints improve resource selection inference in the presence of telemetry error

    Science.gov (United States)

    Brost, Brian M.; Hooten, Mevin B.; Hanks, Ephraim M.; Small, Robert J.

    2016-01-01

    Multiple factors complicate the analysis of animal telemetry location data. Recent advancements address issues such as temporal autocorrelation and telemetry measurement error, but additional challenges remain. Difficulties introduced by complicated error structures or barriers to animal movement can weaken inference. We propose an approach for obtaining resource selection inference from animal location data that accounts for complicated error structures, movement constraints, and temporally autocorrelated observations. We specify a model for telemetry data observed with error conditional on unobserved true locations that reflects prior knowledge about constraints in the animal movement process. The observed telemetry data are modeled using a flexible distribution that accommodates extreme errors and complicated error structures. Although constraints to movement are often viewed as a nuisance, we use constraints to simultaneously estimate and account for telemetry error. We apply the model to simulated data, showing that it outperforms common ad hoc approaches used when confronted with measurement error and movement constraints. We then apply our framework to an Argos satellite telemetry data set on harbor seals (Phoca vitulina) in the Gulf of Alaska, a species that is constrained to move within the marine environment and adjacent coastlines.

  8. Packet telemetry and packet telecommand - The new generation of spacecraft data handling techniques

    Science.gov (United States)

    Hooke, A. J.

    1983-01-01

    Because of rising costs and reduced reliability of spacecraft and ground network hardware and software customization, standardization Packet Telemetry and Packet Telecommand concepts are emerging as viable alternatives. Autonomous packets of data, within each concept, which are created within ground and space application processes through the use of formatting techniques, are switched end-to-end through the space data network to their destination application processes through the use of standard transfer protocols. This process may result in facilitating a high degree of automation and interoperability because of completely mission-independent-designed intermediate data networks. The adoption of an international guideline for future space telemetry formatting of the Packet Telemetry concept, and the advancement of the NASA-ESA Working Group's Packet Telecommand concept to a level of maturity parallel to the of Packet Telemetry are the goals of the Consultative Committee for Space Data Systems. Both the Packet Telemetry and Packet Telecommand concepts are reviewed.

  9. UAV telemetry communications using ZigBee protocol

    Science.gov (United States)

    Nasution, T. H.; Siregar, I.; Yasir, M.

    2017-10-01

    Wireless communication has been widely used in various fields or disciplines such as agriculture, health, engineering, military, and aerospace so as to support the work in that field. The communication technology is typically used for controlling devices and data monitoring. One development of wireless communication is the widely used telemetry system used to reach areas that cannot be reached by humans using UAV (Unmanned Aerial Vehicle) or unmanned aircraft. In this paper we discuss the design of telemetry system in UAV using ZigBee protocol. From the test obtained the system can work well with visualization displays without pause is 20 data per second with a maximum data length of 120 characters.

  10. Miniature Optical Isolator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for miniature optical isolators in atom interferometry applications, Physical Optics Corporation (POC) proposes to develop a miniature optical...

  11. Telemetry of Aerial Radiological Measurements

    International Nuclear Information System (INIS)

    Clark, H. W. Jr.

    2002-01-01

    Telemetry has been added to National Nuclear Security Administration's (NNSA's) Aerial Measuring System (AMS) Incident Response aircraft to accelerate availability of aerial radiological mapping data. Rapid aerial radiological mapping is promptly performed by AMS Incident Response aircraft in the event of a major radiological dispersal. The AMS airplane flies the entire potentially affected area, plus a generous margin, to provide a quick look at the extent and severity of the event. The primary result of the AMS Incident Response over flight is a map of estimated exposure rate on the ground along the flight path. Formerly, it was necessary to wait for the airplane to land before the map could be seen. Now, while the flight is still in progress, data are relayed via satellite directly from the aircraft to an operations center, where they are displayed and disseminated. This permits more timely utilization of results by decision makers and redirection of the mission to optimize its value. The current telemetry capability can cover all of North America. Extension to a global capability is under consideration

  12. Dr.Johnson's Dictionary in Miniature

    OpenAIRE

    Imazato, Chiaki

    1988-01-01

    More than hundred 'Johnson's' dictionaries have so far been published not only in English but in other countries, and there are numerous books and articles on Johnson's Dictionary. But few have referred to Johnson's Dictionary in Miniature; nor were there any books or articles on it. Fortunately, however, I've got one copy of Johnson's Dictionary in Miniature, which was published in 1806. Johnson's Dictionary (1755) has 41,677 entries, whereas Johnson's Dictionary in Miniature 23,439 entr...

  13. Telemetry and Science Data Software System

    Science.gov (United States)

    Bates, Lakesha; Hong, Liang

    2011-01-01

    The Telemetry and Science Data Software System (TSDSS) was designed to validate the operational health of a spacecraft, ease test verification, assist in debugging system anomalies, and provide trending data and advanced science analysis. In doing so, the system parses, processes, and organizes raw data from the Aquarius instrument both on the ground and while in space. In addition, it provides a user-friendly telemetry viewer, and an instant pushbutton test report generator. Existing ground data systems can parse and provide simple data processing, but have limitations in advanced science analysis and instant report generation. The TSDSS functions as an offline data analysis system during I&T (integration and test) and mission operations phases. After raw data are downloaded from an instrument, TSDSS ingests the data files, parses, converts telemetry to engineering units, and applies advanced algorithms to produce science level 0, 1, and 2 data products. Meanwhile, it automatically schedules upload of the raw data to a remote server and archives all intermediate and final values in a MySQL database in time order. All data saved in the system can be straightforwardly retrieved, exported, and migrated. Using TSDSS s interactive data visualization tool, a user can conveniently choose any combination and mathematical computation of interesting telemetry points from a large range of time periods (life cycle of mission ground data and mission operations testing), and display a graphical and statistical view of the data. With this graphical user interface (GUI), the data queried graphs can be exported and saved in multiple formats. This GUI is especially useful in trending data analysis, debugging anomalies, and advanced data analysis. At the request of the user, mission-specific instrument performance assessment reports can be generated with a simple click of a button on the GUI. From instrument level to observatory level, the TSDSS has been operating supporting

  14. Telemetry location error in a forested habitat

    Science.gov (United States)

    Chu, D.S.; Hoover, B.A.; Fuller, M.R.; Geissler, P.H.; Amlaner, Charles J.

    1989-01-01

    The error associated with locations estimated by radio-telemetry triangulation can be large and variable in a hardwood forest. We assessed the magnitude and cause of telemetry location errors in a mature hardwood forest by using a 4-element Yagi antenna and compass bearings toward four transmitters, from 21 receiving sites. The distance error from the azimuth intersection to known transmitter locations ranged from 0 to 9251 meters. Ninety-five percent of the estimated locations were within 16 to 1963 meters, and 50% were within 99 to 416 meters of actual locations. Angles with 20o of parallel had larger distance errors than other angles. While angle appeared most important, greater distances and the amount of vegetation between receivers and transmitters also contributed to distance error.

  15. Telemetry System Data Latency

    Science.gov (United States)

    2017-07-13

    latencies will be measured. DATS Network TM Antenna TM ReceiverMCS System IOPlex IOPlexIADS CDS IADS Client TM Transmitter Sensors Signal Conditioning...TIME Figure 1-2 Mission Control System (MCS) / Interactive Analysis and Display System (IADS) Overview IADS CDSIADS Client TELEMETRY SYSTEM DATA...Sim GPS Signal Combiner MCS system Oscilloscope IADS Client IADS CDS Figure 13-1 IADS Data Flow 13.2. Test Results The results of the data test at

  16. HMSRP Hawaiian Monk Seal Telemetry Tag Deployments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  17. Miniature EVA Software Defined Radio

    Science.gov (United States)

    Pozhidaev, Aleksey

    2012-01-01

    As NASA embarks upon developing the Next-Generation Extra Vehicular Activity (EVA) Radio for deep space exploration, the demands on EVA battery life will substantially increase. The number of modes and frequency bands required will continue to grow in order to enable efficient and complex multi-mode operations including communications, navigation, and tracking applications. Whether conducting astronaut excursions, communicating to soldiers, or first responders responding to emergency hazards, NASA has developed an innovative, affordable, miniaturized, power-efficient software defined radio that offers unprecedented power-efficient flexibility. This lightweight, programmable, S-band, multi-service, frequency- agile EVA software defined radio (SDR) supports data, telemetry, voice, and both standard and high-definition video. Features include a modular design, an easily scalable architecture, and the EVA SDR allows for both stationary and mobile battery powered handheld operations. Currently, the radio is equipped with an S-band RF section. However, its scalable architecture can accommodate multiple RF sections simultaneously to cover multiple frequency bands. The EVA SDR also supports multiple network protocols. It currently implements a Hybrid Mesh Network based on the 802.11s open standard protocol. The radio targets RF channel data rates up to 20 Mbps and can be equipped with a real-time operating system (RTOS) that can be switched off for power-aware applications. The EVA SDR's modular design permits implementation of the same hardware at all Network Nodes concept. This approach assures the portability of the same software into any radio in the system. It also brings several benefits to the entire system including reducing system maintenance, system complexity, and development cost.

  18. Evaluation of a miniature microscope objective designed for fluorescence array microscopy detection of Mycobacterium tuberculosis.

    Science.gov (United States)

    McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S

    2014-03-01

    A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.

  19. Aquatic animal telemetry: A panoramic window into the underwater world

    DEFF Research Database (Denmark)

    Hussey, Nigel E.; Kessel, Steven T.; Aarestrup, Kim

    2015-01-01

    The distribution and interactions of aquatic organisms across space and time structure our marine, freshwater, and estuarine ecosystems. Over the past decade, technological advances in telemetry have transformed our ability to observe aquatic animal behavior and movement. These advances are now p...... individuals, populations, and entire ecosystems. The next advance in aquatic telemetry will be the development of a global collaborative effort to facilitate infrastructure and data sharing and management over scales not previously possible....

  20. Tracking anguillid eels: five decades of telemetry-based research

    DEFF Research Database (Denmark)

    Beguer-Pon, Melanie; Dodson, Julian J.; Castonguay, Martin

    2018-01-01

    anguillid species have been tracked in three main geographical locations: Western Europe, the north-eastern part of North America and Australasia. Telemetry has proven to be an effective method for determining patterns of yellow eel movements in continental waters. It has also been used extensively...... satellite tags have provided indications of spawning areas, extensive vertical migrations and initial clues about the orientation mechanisms at sea. Telemetry studies have also revealed apparent evidence of predation by marine mammals and fish at sea, suggesting a significant natural source of mortality...

  1. A telemetry experiment on spotted grunter Pomadasys ...

    African Journals Online (AJOL)

    associated fish in South Africa was investigated by conducting a tracking experiment on spotted grunter Pomadasys commersonnii in the East Kleinemonde Estuary. The telemetry equipment comprised two VEMCO V8 transmitters and a ...

  2. The miniature accelerator

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The image that most people have of CERN is of its enormous accelerators and their capacity to accelerate particles to extremely high energies. But thanks to some cutting-edge studies on beam dynamics and radiofrequency technology, along with innovative construction techniques, teams at CERN have now created the first module of a brand-new accelerator, which will be just 2 metres long. The potential uses of this miniature accelerator will include deployment in hospitals for the production of medical isotopes and the treatment of cancer. It’s a real David-and-Goliath story.   Serge Mathot, in charge of the construction of the "mini-RFQ", pictured with the first of the four modules that will make up the miniature accelerator. The miniature accelerator consists of a radiofrequency quadrupole (RFQ), a component found at the start of all proton accelerator chains around the world, from the smallest to the largest. The LHC is designed to produce very high-intensity beams ...

  3. Strange Animals and Creatures in Islamic Miniatures: Focusing on Miniatures of the Conference of the Birds

    Directory of Open Access Journals (Sweden)

    Neda Rohani

    2017-09-01

    Full Text Available Strange animals and creatures have always existed in every mythological culture. In Iran's pre-Islamic and post-Islamic miniatures and reliefs, there are many strange animals and creatures such as dragons and phoenix which were associated with the Iranian culture and civilization. Because of presence of these strange creatures, particularly human life, these creatures are first used in mythological life and then symbolically to express human ideas. However, these animals were present in both mythology and epics and, later in the Islamic era, in the mystical stories, educational stories and admonishing anecdotes like Sanai, Attar, and Rumi. This study tends to investigate genealogy of strange animals and creatures in ancient Iranian reliefs and their continued presence in miniatures of Islamic era as well as presence of these creatures in miniatures which are based on Attar’s Conference of the Birds. In fact, this study reviews elements and symbolic concepts of animals, allowing a deeper understanding of function of elements and symbolism in works of Iranian miniaturists. Contemplation of miniatures, icons and the relationship between literature and miniatures will lead to many results in recognition of mystical intellectual foundations. Therefore, this study tends to investigate mysterious and unknown aspects of Iranian miniatures and find their relationship with culture and stories.

  4. Visual thread quality for precision miniature mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1981-04-01

    Threaded features have eight visual appearance factors which can affect their function in precision miniature mechanisms. The Bendix practice in deburring, finishing, and accepting these conditions on miniature threads is described as is their impact in assemblies of precision miniature electromechanical assemblies.

  5. Telemetry Timing Analysis for Image Reconstruction of Kompsat Spacecraft

    Directory of Open Access Journals (Sweden)

    Jin-Ho Lee

    2000-06-01

    Full Text Available The KOMPSAT (KOrea Multi-Purpose SATellite has two optical imaging instruments called EOC (Electro-Optical Camera and OSMI (Ocean Scanning Multispectral Imager. The image data of these instruments are transmitted to ground station and restored correctly after post-processing with the telemetry data transferred from KOMPSAT spacecraft. The major timing information of the KOMPSAT is OBT (On-Board Time which is formatted by the on-board computer of the spacecraft, based on 1Hz sync. pulse coming from the GPS receiver involved. The OBT is transmitted to ground station with the house-keeping telemetry data of the spacecraft while it is distributed to the instruments via 1553B data bus for synchronization during imaging and formatting. The timing information contained in the spacecraft telemetry data would have direct relation to the image data of the instruments, which should be well explained to get a more accurate image. This paper addresses the timing analysis of the KOMPSAT spacecraft and instruments, including the gyro data timing analysis for the correct restoration of the EOC and OSMI image data at ground station.

  6. A Comprehensive Investigation of Advanced Range Telemetry

    National Research Council Canada - National Science Library

    Rice, Michael

    1999-01-01

    Data from ARTM channel sounding flights has been analyzed. A three-path model consisting of a line-of-sight path and two reflected paths adequately captures all the essential multipath features of the aeronautical telemetry channel...

  7. A strategy for recovering continuous behavioral telemetry data from Pacific walruses

    Science.gov (United States)

    Fischbach, Anthony S.; Jay, Chadwick V.

    2016-01-01

    Tracking animal behavior and movement with telemetry sensors can offer substantial insights required for conservation. Yet, the value of data collected by animal-borne telemetry systems is limited by bandwidth constraints. To understand the response of Pacific walruses (Odobenus rosmarus divergens) to rapid changes in sea ice availability, we required continuous geospatial chronologies of foraging behavior. Satellite telemetry offered the only practical means to systematically collect such data; however, data transmission constraints of satellite data-collection systems limited the data volume that could be acquired. Although algorithms exist for reducing sensor data volumes for efficient transmission, none could meet our requirements. Consequently, we developed an algorithm for classifying hourly foraging behavior status aboard a tag with limited processing power. We found a 98% correspondence of our algorithm's classification with a test classification based on time–depth data recovered and characterized through multivariate analysis in a separate study. We then applied our algorithm within a telemetry system that relied on remotely deployed satellite tags. Data collected by these tags from Pacific walruses across their range during 2007–2015 demonstrated the consistency of foraging behavior collected by this strategy with data collected by data logging tags; and demonstrated the ability to collect geospatial behavioral chronologies with minimal missing data where recovery of data logging tags is precluded. Our strategy for developing a telemetry system may be applicable to any study requiring intelligent algorithms to continuously monitor behavior, and then compress those data into meaningful information that can be efficiently transmitted.

  8. Advances in Miniaturized Instruments for Genomics

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2014-01-01

    Full Text Available In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices.

  9. Prototype Sistem Multi-Telemetri Wireless untuk Mengukur Suhu Udara Berbasis Mikrokontroler ESP8266 pada Greenhouse

    OpenAIRE

    Hanum Shirotu Nida

    2017-01-01

    Telemetri wireless adalah proses pengukuran parameter suatu obyek yang hasil pengukurannya dikirimkan ke tempat lain melalui proses pengiriman data tanpa menggunakan kabel (wireless), sedangkan multi telemetri adalah gabungan dari beberapa telemeteri itu sendiri. Penelitian ini merancang prototype sistem multi-telemetri wireless untuk mengukur suhu udara dan kelembaban udara pada greenhouse dengan menggunakan sensor DHT11 dan data hasil dari pembacaan sensor dikirim dengan menggunakan modul W...

  10. Can telemetry data obviate the need for sleep studies in Pierre Robin Sequence?

    Science.gov (United States)

    Aaronson, Nicole Leigh; Jabbour, Noel

    2017-09-01

    This study looks to correlate telemetry data gathered on patients with Pierre Robin Sequence (PRS) with sleep study data. Strong correlation might allow obstructive sleep apnea (OSA) to be reasonably predicted without the need for sleep study. Charts from forty-six infants with PRS who presented to our children's hospital between 2005 and 2015 and received a polysomnogram (PSG) prior to surgical intervention were retrospectively reviewed. Correlations and scatterplots were used to compare average daily oxygen nadir, overall oxygen nadir, and average number of daily desaturations from telemetry data with apnea-hypopnea index (AHI) and oxygen nadir on sleep study. Results were also categorized into groups of AHI ≥ or sleep study data. Patients with O2 nadir below 80% on telemetry were not more likely to have an O2 nadir below 80% on sleep study. Patients with an average O2 nadir below 80% did show some correlation with having an AHI greater than 10 on sleep study but this relationship did not reach significance. Of 22 patients who did not have any desaturations on telemetry below 80%, 16 (73%) had an AHI >10 on sleep study. In the workup of infants with PRS, the index of suspicion is high for OSA. In our series, telemetry data was not useful in ruling out severe OSA. Thus our data do not support forgoing sleep study in patients with PRS and concern for OSA despite normal telemetry patterns. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Preliminary PANSAT ground station software design and use of an expert system to analyze telemetry

    Science.gov (United States)

    Lawrence, Gregory W.

    1994-03-01

    The Petite Amateur Navy Satellite (PANSAT) is a communications satellite designed to be used by civilian amateur radio operators. A master ground station is being built at the Naval Postgraduate School. This computer system performs satellite commands, displays telemetry, trouble-shoots problems, and passes messages. The system also controls an open loop tracking antenna. This paper concentrates on the telemetry display, decoding, and interpretation through artificial intelligence (AI). The telemetry is displayed in an easily interpretable format, so that any user can understand the current health of the satellite and be cued as to any problems and possible solutions. Only the master ground station has the ability to receive all telemetry and send commands to the spacecraft; civilian ham users do not have access to this information. The telemetry data is decommutated and analyzed before it is displayed to the user, so that the raw data will not have to be interpreted by ground users. The analysis will use CLIPS imbedded in the code, and derive its inputs from telemetry decommutation. The program is an expert system using a forward chaining set of rules based on the expected operation and parameters of the satellite. By building the rules during the construction and design of the satellite, the telemetry can be well understood and interpreted after the satellite is launched and the designers may no longer be available to provide input to the problem.

  12. Integrated Plan-Procedures-Telemetry Ops Concept and Prototype

    Data.gov (United States)

    National Aeronautics and Space Administration — The project scope includes developing the ops concept and prototype for a near-seamless interface between mission plans, electronic procedures and live telemetry...

  13. The Economic Importance of Adequate Aeronautical Telemetry Spectrum

    National Research Council Canada - National Science Library

    Kahn, Carolyn A

    2005-01-01

    INTRODUCTION: (1) The flight test community faces a telemetry spectrum crunch; (2) Amount of spectrum now allocated for ATM is not sufficient to meet needs, and requirements have been steadily growing...

  14. Field tests of acoustic telemetry for a portable coastal observatory

    Science.gov (United States)

    Martini, M.; Butman, B.; Ware, J.; Frye, D.

    2006-01-01

    Long-term field tests of a low-cost acoustic telemetry system were carried out at two sites in Massachusetts Bay. At each site, an acoustic Doppler current profiler mounted on a bottom tripod was fitted with an acoustic modem to transmit data to a surface buoy; electronics mounted on the buoy relayed these data to shore via radio modem. The mooring at one site (24 m water depth) was custom-designed for the telemetry application, with a custom designed small buoy, a flexible electro-mechanical buoy to mooring joint using a molded chain connection to the buoy, quick-release electro-mechanical couplings, and dual hydrophones suspended 7 m above the bottom. The surface buoy at the second site (33 m water depth) was a U.S. Coast Guard (USCG) channel buoy fitted with telemetry electronics and clamps to hold the hydrophones. The telemetry was tested in several configurations for a period of about four years. The custom-designed buoy and mooring provided nearly error-free data transmission through the acoustic link under a variety of oceanographic conditions for 261 days at the 24 m site. The electro mechanical joint, cables and couplings required minimal servicing and were very reliable, lasting 862 days deployed before needing repairs. The acoustic communication results from the USCG buoy were poor, apparently due to the hard cobble bottom, noise from the all-steel buoy, and failure of the hydrophone assembly. Access to the USCG buoy at sea required ideal weather. ??2006 IEEE.

  15. Cerebellar abiotrophy in a miniature schnauzer

    OpenAIRE

    Berry, Michelle L.; Blas-Machado, Uriel

    2003-01-01

    A 3.5-month-old miniature schnauzer was presented for signs of progressive cerebellar ataxia. Necropsy revealed cerebellar abiotrophy. This is the first reported case of cerebellar abiotrophy in a purebred miniature schnauzer.

  16. Cerebellar abiotrophy in a miniature schnauzer.

    Science.gov (United States)

    Berry, Michelle L; Blas-Machado, Uriel

    2003-08-01

    A 3.5-month-old miniature schnauzer was presented for signs of progressive cerebellar ataxia. Necropsy revealed cerebellar abiotrophy. This is the first reported case of cerebellar abiotrophy in a purebred miniature schnauzer.

  17. Sonata: Query-Driven Network Telemetry

    KAUST Repository

    Gupta, Arpit; Harrison, Rob; Pawar, Ankita; Birkner, Rü diger; Canini, Marco; Feamster, Nick; Rexford, Jennifer; Willinger, Walter

    2017-01-01

    Operating networks depends on collecting and analyzing measurement data. Current technologies do not make it easy to do so, typically because they separate data collection (e.g., packet capture or flow monitoring) from analysis, producing either too much data to answer a general question or too little data to answer a detailed question. In this paper, we present Sonata, a network telemetry system that uses a uniform query interface to drive the joint collection and analysis of network traffic. Sonata takes the advantage of two emerging technologies---streaming analytics platforms and programmable network devices---to facilitate joint collection and analysis. Sonata allows operators to more directly express network traffic analysis tasks in terms of a high-level language. The underlying runtime partitions each query into a portion that runs on the switch and another that runs on the streaming analytics platform iteratively refines the query to efficiently capture only the traffic that pertains to the operator's query, and exploits sketches to reduce state in switches in exchange for more approximate results. Through an evaluation of a prototype implementation, we demonstrate that Sonata can support a wide range of network telemetry tasks with less state in the network, and lower data rates to streaming analytics systems, than current approaches can achieve.

  18. Sonata: Query-Driven Network Telemetry

    KAUST Repository

    Gupta, Arpit

    2017-05-02

    Operating networks depends on collecting and analyzing measurement data. Current technologies do not make it easy to do so, typically because they separate data collection (e.g., packet capture or flow monitoring) from analysis, producing either too much data to answer a general question or too little data to answer a detailed question. In this paper, we present Sonata, a network telemetry system that uses a uniform query interface to drive the joint collection and analysis of network traffic. Sonata takes the advantage of two emerging technologies---streaming analytics platforms and programmable network devices---to facilitate joint collection and analysis. Sonata allows operators to more directly express network traffic analysis tasks in terms of a high-level language. The underlying runtime partitions each query into a portion that runs on the switch and another that runs on the streaming analytics platform iteratively refines the query to efficiently capture only the traffic that pertains to the operator\\'s query, and exploits sketches to reduce state in switches in exchange for more approximate results. Through an evaluation of a prototype implementation, we demonstrate that Sonata can support a wide range of network telemetry tasks with less state in the network, and lower data rates to streaming analytics systems, than current approaches can achieve.

  19. The application of GPS time information in the telemetry ground station

    International Nuclear Information System (INIS)

    Zhang Songtao; Zhang Yusong; Sun Xiurui

    2001-01-01

    GPS time information is a kind of practicable information resource that can be shared all over the world. Now it is the most accurate wireless time information. The major of this paper is the application information of GPS time information in telemetry. The main point introduces how to make use of the GPS time information to produce GPS-IRIG-B time code for proving ground and how to send time information to related equipment in telemetry ground station

  20. Mechano-Magnetic Telemetry for Underground Water Infrastructure Monitoring

    Directory of Open Access Journals (Sweden)

    Daniel Orfeo

    2018-06-01

    Full Text Available This study reports on the theory of operation, design principles, and results from laboratory and field tests of a magnetic telemetry system for communication with underground infrastructure sensors using rotating permanent magnets as the sources and compact magnetometers as the receivers. Many cities seek ways to monitor underground water pipes with centrally managed Internet of Things (IoT systems. This requires the development of numerous reliable low-cost wireless sensors, such as moisture sensors and flow meters, which can transmit information from subterranean pipes to surface-mounted receivers. Traditional megahertz radio communication systems are often unable to penetrate through multiple feet of earthen and manmade materials and have impractically large energy requirements which preclude the use of long-life batteries, require complex (and expensive built-in energy harvesting systems, or long leads that run antennas near to the surface. Low-power magnetic signaling systems do not suffer from this drawback: low-frequency electromagnetic waves readily penetrate through several feet of earth and water. Traditional magnetic telemetry systems that use energy-inefficient large induction coils and antennas as sources and receivers are not practical for underground IoT-type sensing applications. However, rotating a permanent magnet creates a completely reversing oscillating magnetic field. The recent proliferation of strong rare-earth permanent magnets and high-sensitivity magnetometers enables alternative magnetic telemetry system concepts with significantly more compact formats and lower energy consumption. The system used in this study represents a novel combination of megahertz radio and magnetic signaling techniques for the purposes of underground infrastructure monitoring. In this study, two subterranean infrastructure sensors exploit this phenomenon to transmit information to an aboveground radio-networked magnetometer receiver. A flow

  1. X-33 Telemetry Best Source Selection, Processing, Display, and Simulation Model Comparison

    Science.gov (United States)

    Burkes, Darryl A.

    1998-01-01

    The X-33 program requires the use of multiple telemetry ground stations to cover the launch, ascent, transition, descent, and approach phases for the flights from Edwards AFB to landings at Dugway Proving Grounds, UT and Malmstrom AFB, MT. This paper will discuss the X-33 telemetry requirements and design, including information on fixed and mobile telemetry systems, best source selection, and support for Range Safety Officers. A best source selection system will be utilized to automatically determine the best source based on the frame synchronization status of the incoming telemetry streams. These systems will be used to select the best source at the landing sites and at NASA Dryden Flight Research Center to determine the overall best source between the launch site, intermediate sites, and landing site sources. The best source at the landing sites will be decommutated to display critical flight safety parameters for the Range Safety Officers. The overall best source will be sent to the Lockheed Martin's Operational Control Center at Edwards AFB for performance monitoring by X-33 program personnel and for monitoring of critical flight safety parameters by the primary Range Safety Officer. The real-time telemetry data (received signal strength, etc.) from each of the primary ground stations will also be compared during each nu'ssion with simulation data generated using the Dynamic Ground Station Analysis software program. An overall assessment of the accuracy of the model will occur after each mission. Acknowledgment: The work described in this paper was NASA supported through cooperative agreement NCC8-115 with Lockheed Martin Skunk Works.

  2. Finding our way: On the sharing and reuse of animal telemetry data in Australasia

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Hamish A., E-mail: hamish.campbell@une.edu.au [Department of Ecosystem Management, School of Environment and Rural Sciences, University of New England, Armidale, NSW (Australia); Beyer, Hawthorne L. [ARC Centre of Excellence for Environmental Decisions, Centre for Biodiversity & Conservation Science, University of Queensland, Brisbane, QLD (Australia); Dennis, Todd E. [School of Biological Sciences, University of Auckland, Private Bag 92019, Auckland (New Zealand); Dwyer, Ross G. [School of Biological Sciences, University of Queensland, St Lucia, QLD (Australia); Forester, James D. [Dept. Fisheries, Wildlife, and Conservation Biology, University of Minnesota, St. Paul, MN (United States); Fukuda, Yusuke [Department of Land Resource Management, PO Box 496, Palmerston, NT (Australia); Lynch, Catherine [Arid Recovery, PO Box 147, Roxby Downs, SA (Australia); Hindell, Mark A. [University of Tasmania, Hobart, TAS (Australia); Menke, Norbert [Queensland Department of Science, Information, Technoloty, Innovation and the Arts, Brisbane, QLD (Australia); Morales, Juan M. [Ecotono, INIBIOMA—CONICET, Universidad Nacional del Comahue, Quintral 1250, 8400 Bariloche (Argentina); Richardson, Craig [Ecological Resources Information Network, Department of the Environment, Canberra, ACT (Australia); Rodgers, Essie [School of Biological Sciences, University of Queensland, St Lucia, QLD (Australia); Taylor, Graeme [Department of Conservation, PO Box 10420, Wellington 6143 (New Zealand); Watts, Matt E. [ARC Centre of Excellence for Environmental Decisions, Centre for Biodiversity & Conservation Science, University of Queensland, Brisbane, QLD (Australia); Westcott, David A. [Commonwealth Scientific and Industrial Research Organisation, PO Box 780, Atherton, QLD (Australia)

    2015-11-15

    The presence and movements of organisms both reflect and influence the distribution of ecological resources in space and time. The monitoring of animal movement by telemetry devices is being increasingly used to inform management of marine, freshwater and terrestrial ecosystems. Here, we brought together academics, and environmental managers to determine the extent of animal movement research in the Australasian region, and assess the opportunities and challenges in the sharing and reuse of these data. This working group was formed under the Australian Centre for Ecological Analysis and Synthesis (ACEAS), whose overall aim was to facilitate trans-organisational and transdisciplinary synthesis. We discovered that between 2000 and 2012 at least 501 peer-reviewed scientific papers were published that report animal location data collected by telemetry devices from within the Australasian region. Collectively, this involved the capture and electronic tagging of 12 656 animals. The majority of studies were undertaken to address specific management questions; rarely were these data used beyond their original intent. We estimate that approximately half (~ 500) of all animal telemetry projects undertaken remained unpublished, a similar proportion were not discoverable via online resources, and less than 8.8% of all animals tagged and tracked had their data stored in a discoverable and accessible manner. Animal telemetry data contain a wealth of information about how animals and species interact with each other and the landscapes they inhabit. These data are expensive and difficult to collect and can reduce survivorship of the tagged individuals, which implies an ethical obligation to make the data available to the scientific community. This is the first study to quantify the gap between telemetry devices placed on animals and findings/data published, and presents methods for improvement. Instigation of these strategies will enhance the cost-effectiveness of the research and

  3. Finding our way: On the sharing and reuse of animal telemetry data in Australasia

    International Nuclear Information System (INIS)

    Campbell, Hamish A.; Beyer, Hawthorne L.; Dennis, Todd E.; Dwyer, Ross G.; Forester, James D.; Fukuda, Yusuke; Lynch, Catherine; Hindell, Mark A.; Menke, Norbert; Morales, Juan M.; Richardson, Craig; Rodgers, Essie; Taylor, Graeme; Watts, Matt E.; Westcott, David A.

    2015-01-01

    The presence and movements of organisms both reflect and influence the distribution of ecological resources in space and time. The monitoring of animal movement by telemetry devices is being increasingly used to inform management of marine, freshwater and terrestrial ecosystems. Here, we brought together academics, and environmental managers to determine the extent of animal movement research in the Australasian region, and assess the opportunities and challenges in the sharing and reuse of these data. This working group was formed under the Australian Centre for Ecological Analysis and Synthesis (ACEAS), whose overall aim was to facilitate trans-organisational and transdisciplinary synthesis. We discovered that between 2000 and 2012 at least 501 peer-reviewed scientific papers were published that report animal location data collected by telemetry devices from within the Australasian region. Collectively, this involved the capture and electronic tagging of 12 656 animals. The majority of studies were undertaken to address specific management questions; rarely were these data used beyond their original intent. We estimate that approximately half (~ 500) of all animal telemetry projects undertaken remained unpublished, a similar proportion were not discoverable via online resources, and less than 8.8% of all animals tagged and tracked had their data stored in a discoverable and accessible manner. Animal telemetry data contain a wealth of information about how animals and species interact with each other and the landscapes they inhabit. These data are expensive and difficult to collect and can reduce survivorship of the tagged individuals, which implies an ethical obligation to make the data available to the scientific community. This is the first study to quantify the gap between telemetry devices placed on animals and findings/data published, and presents methods for improvement. Instigation of these strategies will enhance the cost-effectiveness of the research and

  4. Multi-purpose ECG telemetry system.

    Science.gov (United States)

    Marouf, Mohamed; Vukomanovic, Goran; Saranovac, Lazar; Bozic, Miroslav

    2017-06-19

    The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results

  5. Inheritance of congenital cataracts and microphthalmia in the Miniature Schnauzer.

    Science.gov (United States)

    Gelatt, K N; Samuelson, D A; Bauer, J E; Das, N D; Wolf, E D; Barrie, K P; Andresen, T L

    1983-06-01

    Congenital cataracts and microphthalmia in the Miniature Schnauzer were inherited as an autosomal recessive trait. Eighteen matings of affected X affected Miniature Schnauzers resulted in 87 offspring with congenital cataracts and microphthalmia (49 males/38 females). Two matings of congenital cataractous and microphthalmic Miniature Schnauzers (2 females) X a normal Miniature Schnauzer (1 male) yielded 11 clinically normal Miniature Schnauzers (7 males/4 females). Eighteen matings of congenital cataractous and microphthalmic Miniature Schnauzers (6 males) X carrier Miniature Schnauzers (9 females) produced 81 offspring; 39 exhibited congenital cataracts and microphthalmia (20 males/19 females) and 42 had clinically normal eyes (17 males/25 females).

  6. The integrated satellite-acoustic telemetry (iSAT) system for tracking marine megafauna

    KAUST Repository

    De la Torre, Pedro

    2012-10-06

    This document describes the integrated satellite-acoustic telemetry (iSAT) system: an autonomous modular system for tracking the movements of large pelagic fish using acoustic telemetry and satellite communications. The sensor platform is described along with the propulsion and navigation systems. An application for tracking the whale shark (Rhincodon typus) in the Red Sea is included along with a discussion of the technical difficulties that such a system faces.

  7. The integrated satellite-acoustic telemetry (iSAT) system for tracking marine megafauna

    KAUST Repository

    De la Torre, Pedro; Berumen, Michael L.; Salama, Khaled N.; Smith, E. Lloyd

    2012-01-01

    This document describes the integrated satellite-acoustic telemetry (iSAT) system: an autonomous modular system for tracking the movements of large pelagic fish using acoustic telemetry and satellite communications. The sensor platform is described along with the propulsion and navigation systems. An application for tracking the whale shark (Rhincodon typus) in the Red Sea is included along with a discussion of the technical difficulties that such a system faces.

  8. Serum C-reactive protein concentrations in healthy Miniature Schnauzer dogs.

    Science.gov (United States)

    Wong, Valerie M; Kidney, Beverly A; Snead, Elisabeth C R; Myers, Sherry L; Jackson, Marion L

    2011-09-01

    C-reactive protein (CRP) is a sensitive marker for inflammation in people and dogs. In people, an association between CRP concentration and atherosclerosis has been reported. Atherosclerosis is rare in dogs, but the Miniature Schnauzer breed may be at increased risk for developing this vascular disease. It is not known if CRP concentrations in Miniature Schnauzer dogs differ from those in other dog breeds. Our objectives were to validate an automated human CRP assay for measuring CRP in dogs and compare CRP concentrations in healthy Miniature Schnauzer dogs with those in non-Miniature Schnauzer breeds. Sera from 37 non-Miniature Schnauzer dogs with inflammatory disease were pooled and used to validate a human CRP immunoturbidimetric assay for measuring canine CRP. Blood was collected from 20 healthy Miniature Schnauzer dogs and 41 healthy dogs of other breeds. Median serum CRP concentration of healthy Miniature Schnauzer dogs was compared with that of healthy non-Miniature Schnauzer dogs. The human CRP assay measured CRP reliably with linearity between 0 and 20 mg/L. CRP concentration for healthy Miniature Schnauzer dogs (median 4.0 mg/L, minimum-maximum 0-18.2 mg/L) was significantly higher than for the healthy non-Miniature Schnauzer dogs (median 0.1 mg/L, minimum-maximum 0-10.7 mg/L); 17 of the 20 Miniature Schnauzer dogs had values that overlapped with those of the non-Miniature Schnauzer dogs. Median CRP concentration of Miniature Schnauzer dogs was slightly higher than that of other breeds of dogs. A relationship between higher CRP concentration in Miniature Schnauzer dogs and idiopathic hyperlipidemia, pancreatitis, and possible increased risk for atherosclerosis remains to be determined. ©2011 American Society for Veterinary Clinical Pathology.

  9. A miniature bidirectional telemetry system for in vivo gastric slow wave recordings

    International Nuclear Information System (INIS)

    Farajidavar, Aydin; Chiao, J-C; O'Grady, Gregory; Rao, Smitha M N; Cheng, Leo K; Abell, Thomas

    2012-01-01

    Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical user interface. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the back-end is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm 3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo, slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min −1 ), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 386 µV; p < 0.001). This telemetric system for slow wave acquisition is reliable, power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients. (note)

  10. A combined telemetry - tag return approach to estimate fishing and natural mortality rates of an estuarine fish

    Science.gov (United States)

    Bacheler, N.M.; Buckel, J.A.; Hightower, J.E.; Paramore, L.M.; Pollock, K.H.

    2009-01-01

    A joint analysis of tag return and telemetry data should improve estimates of mortality rates for exploited fishes; however, the combined approach has thus far only been tested in terrestrial systems. We tagged subadult red drum (Sciaenops ocellatus) with conventional tags and ultrasonic transmitters over 3 years in coastal North Carolina, USA, to test the efficacy of the combined telemetry - tag return approach. There was a strong seasonal pattern to monthly fishing mortality rate (F) estimates from both conventional and telemetry tags; highest F values occurred in fall months and lowest levels occurred during winter. Although monthly F values were similar in pattern and magnitude between conventional tagging and telemetry, information on F in the combined model came primarily from conventional tags. The estimated natural mortality rate (M) in the combined model was low (estimated annual rate ?? standard error: 0.04 ?? 0.04) and was based primarily upon the telemetry approach. Using high-reward tagging, we estimated different tag reporting rates for state agency and university tagging programs. The combined telemetry - tag return approach can be an effective approach for estimating F and M as long as several key assumptions of the model are met.

  11. A Primer for Telemetry Interfacing in Accordance with NASA Standards Using Low Cost FPGAs

    Science.gov (United States)

    McCoy, Jake; Schultz, Ted; Tutt, James; Rogers, Thomas; Miles, Drew; McEntaffer, Randall

    2016-03-01

    Photon counting detector systems on sounding rocket payloads often require interfacing asynchronous outputs with a synchronously clocked telemetry (TM) stream. Though this can be handled with an on-board computer, there are several low cost alternatives including custom hardware, microcontrollers and field-programmable gate arrays (FPGAs). This paper outlines how a TM interface (TMIF) for detectors on a sounding rocket with asynchronous parallel digital output can be implemented using low cost FPGAs and minimal custom hardware. Low power consumption and high speed FPGAs are available as commercial off-the-shelf (COTS) products and can be used to develop the main component of the TMIF. Then, only a small amount of additional hardware is required for signal buffering and level translating. This paper also discusses how this system can be tested with a simulated TM chain in the small laboratory setting using FPGAs and COTS specialized data acquisition products.

  12. High Temperature Telemetry Transmitter for Venus Exploration, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian corrosive, high pressure, 460oC ambient atmosphere without being contained in a...

  13. High Temperature Telemetry Transmitter for Venus Exploration, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian high pressure, 465?aC ambient atmosphere without being contained in a thermally...

  14. Plant Habitat Telemetry / Command Interface and E-MIST

    Science.gov (United States)

    Walker, Uriae M.

    2013-01-01

    Plant Habitat (PH) is an experiment to be taken to the International Space Station (ISS) in 2016. It is critical that ground support computers have the ability to uplink commands to control PH, and that ISS computers have the ability to downlink PH telemetry data to ground support. This necessitates communication software that can send, receive, and process, PH specific commands and telemetry. The objective of the Plant Habitat Telemetry/ Command Interface is to provide this communication software, and to couple it with an intuitive Graphical User Interface (GUI). Initial investigation of the project objective led to the decision that code be written in C++ because of its compatibility with existing source code infrastructures and robustness. Further investigation led to a determination that multiple Ethernet packet structures would need to be created to effectively transmit data. Setting a standard for packet structures would allow us to distinguish these packets that would range from command type packets to sub categories of telemetry packets. In order to handle this range of packet types, the conclusion was made to take an object-oriented programming approach which complemented our decision to use the C++ programming language. In addition, extensive utilization of port programming concepts was required to implement the core functionality of the communication software. Also, a concrete understanding of a packet processing software was required in order to put aU the components of ISS-to-Ground Support Equipment (GSE) communication together and complete the objective. A second project discussed in this paper is Exposing Microbes to the Stratosphere (EMIST). This project exposes microbes into the stratosphere to observe how they are impacted by atmospheric effects. This paper focuses on the electrical and software expectations of the project, specifically drafting the printed circuit board, and programming the on-board sensors. The Eagle Computer-Aided Drafting

  15. Improving estimation of flight altitude in wildlife telemetry studies

    Science.gov (United States)

    Poessel, Sharon; Duerr, Adam E.; Hall, Jonathan C.; Braham, Melissa A.; Katzner, Todd

    2018-01-01

    Altitude measurements from wildlife tracking devices, combined with elevation data, are commonly used to estimate the flight altitude of volant animals. However, these data often include measurement error. Understanding this error may improve estimation of flight altitude and benefit applied ecology.There are a number of different approaches that have been used to address this measurement error. These include filtering based on GPS data, filtering based on behaviour of the study species, and use of state-space models to correct measurement error. The effectiveness of these approaches is highly variable.Recent studies have based inference of flight altitude on misunderstandings about avian natural history and technical or analytical tools. In this Commentary, we discuss these misunderstandings and suggest alternative strategies both to resolve some of these issues and to improve estimation of flight altitude. These strategies also can be applied to other measures derived from telemetry data.Synthesis and applications. Our Commentary is intended to clarify and improve upon some of the assumptions made when estimating flight altitude and, more broadly, when using GPS telemetry data. We also suggest best practices for identifying flight behaviour, addressing GPS error, and using flight altitudes to estimate collision risk with anthropogenic structures. Addressing the issues we describe would help improve estimates of flight altitude and advance understanding of the treatment of error in wildlife telemetry studies.

  16. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  17. Miniaturized module for the wireless transmission of measurements with Bluetooth.

    Science.gov (United States)

    Roth, H; Schwaibold, M; Moor, C; Schöchlin, J; Bolz, A

    2002-01-01

    The wiring of patients for obtaining medical measurements has many disadvantages. In order to limit these, a miniaturized module was developed which digitalizes analog signals and sends the signal wirelessly to the receiver using Bluetooth. Bluetooth is especially suitable for this application because distances of up to 10 m are possible with low power consumption and robust transmission with encryption. The module consists of a Bluetooth chip, which is initialized in such a way by a microcontroller that connections from other bluetooth receivers can be accepted. The signals are then transmitted to the distant end. The maximum bit rate of the 23 mm x 30 mm module is 73.5 kBit/s. At 4.7 kBit/s, the current consumption is 12 mA.

  18. Small Scaffolds, Big Potential: Developing Miniature Proteins as Therapeutic Agents.

    Science.gov (United States)

    Holub, Justin M

    2017-09-01

    Preclinical Research Miniature proteins are a class of oligopeptide characterized by their short sequence lengths and ability to adopt well-folded, three-dimensional structures. Because of their biomimetic nature and synthetic tractability, miniature proteins have been used to study a range of biochemical processes including fast protein folding, signal transduction, catalysis and molecular transport. Recently, miniature proteins have been gaining traction as potential therapeutic agents because their small size and ability to fold into defined tertiary structures facilitates their development as protein-based drugs. This research overview discusses emerging developments involving the use of miniature proteins as scaffolds to design novel therapeutics for the treatment and study of human disease. Specifically, this review will explore strategies to: (i) stabilize miniature protein tertiary structure; (ii) optimize biomolecular recognition by grafting functional epitopes onto miniature protein scaffolds; and (iii) enhance cytosolic delivery of miniature proteins through the use of cationic motifs that facilitate endosomal escape. These objectives are discussed not only to address challenges in developing effective miniature protein-based drugs, but also to highlight the tremendous potential miniature proteins hold for combating and understanding human disease. Drug Dev Res 78 : 268-282, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. An Evidence-Based Approach to Reducing Cardiac Telemetry Alarm Fatigue.

    Science.gov (United States)

    Srinivasa, Ekta; Mankoo, Jaspreet; Kerr, Charles

    2017-08-01

    It is estimated that between 80% and 99% of alarms in the clinical areas are in actionable alarms (Gross, Dahl, & Nielson). Alarm management is one of the Joint Commission's National Patient Safety Goals (2014) because sentinel events have directly been linked to the devices generating these alarms. At an acute care facility in Boston, a multidisciplinary team consisting of Nursing, Biomedical Engineers, Patient Safety and Providers was formed to conduct a pilot study on the state of telemetry alarms on a surgical floor. An evidence-based approach was taken utilizing Philips Real-time data exporter alarms tracking software to capture all telemetry alarms during a 43-day time span. Likewise, noise meters were placed near telemetry alarm speakers to track decibel levels within the aforementioned timeframe for 21 days. Analysis of the data showed that clinically insignificant Premature Ventricular Contractions (PVC) alarms accounted for more than 40% of all alarms in the unit within the time span, while also contributing to an average noise level of 58.49 dB. In response to the data, the interdisciplinary team approved to permanently default the settings for PAIR PVC, MULTIFORM PVC, and RUN PVC alarms to off. The results showed a 54% decrease in the rate of alarms per bed per day, and an average noise reduction of 2.3 dB between the two selected noise measurement areas. Organizing a multidisciplinary team provides an effective framework toward analyzing and addressing cardiac telemetry alarm fatigue. Looking at quantitative datasets for clinical care areas through various lenses helps identify opportunities for improvement in regards to highlighting alarms that are not actionable. Pilot changes to alarm parameters can be tested for their environmental impact in the care area. © 2017 Sigma Theta Tau International.

  20. Miniaturized isothermal nucleic acid amplification, a review.

    Science.gov (United States)

    Asiello, Peter J; Baeumner, Antje J

    2011-04-21

    Micro-Total Analysis Systems (µTAS) for use in on-site rapid detection of DNA or RNA are increasingly being developed. Here, amplification of the target sequence is key to increasing sensitivity, enabling single-cell and few-copy nucleic acid detection. The several advantages to miniaturizing amplification reactions and coupling them with sample preparation and detection on the same chip are well known and include fewer manual steps, preventing contamination, and significantly reducing the volume of expensive reagents. To-date, the majority of miniaturized systems for nucleic acid analysis have used the polymerase chain reaction (PCR) for amplification and those systems are covered in previous reviews. This review provides a thorough overview of miniaturized analysis systems using alternatives to PCR, specifically isothermal amplification reactions. With no need for thermal cycling, isothermal microsystems can be designed to be simple and low-energy consuming and therefore may outperform PCR in portable, battery-operated detection systems in the future. The main isothermal methods as miniaturized systems reviewed here include nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP), helicase-dependent amplification (HDA), rolling circle amplification (RCA), and strand displacement amplification (SDA). Also, important design criteria for the miniaturized devices are discussed. Finally, the potential of miniaturization of some new isothermal methods such as the exponential amplification reaction (EXPAR), isothermal and chimeric primer-initiated amplification of nucleic acids (ICANs), signal-mediated amplification of RNA technology (SMART) and others is presented.

  1. Message Brokering Evaluation for Live Spacecraft Telemetry Monitoring, Recorded Playback, and Analysis

    Science.gov (United States)

    Lee, Daren; Pomerantz, Marc

    2015-01-01

    Live monitoring and post-flight analysis of telemetry data play a vital role in the development, diagnosis, and deployment of components of a space flight mission. Requirements for such a system include low end-to-end latency between data producers and visualizers, preserved ordering of messages, data stream archiving with random access playback, and real-time creation of derived data streams. We evaluate the RabbitMQ and Kafka message brokering systems, on how well they can enable a real-time, scalable, and robust telemetry framework that delivers telemetry data to multiple clients across heterogeneous platforms and flight projects. In our experiments using an actively developed robotic arm testbed, Kafka yielded a much higher message throughput rate and a consistent publishing rate across the number of topics and consumers. Consumer message rates were consistent across the number of topics but can exhibit bursty behavior with an increase in the contention for a single topic partition with increasing number of consumers.

  2. Miniaturization in Biocatalysis

    Directory of Open Access Journals (Sweden)

    Pedro Fernandes

    2010-03-01

    Full Text Available The use of biocatalysts for the production of both consumer goods and building blocks for chemical synthesis is consistently gaining relevance. A significant contribution for recent advances towards further implementation of enzymes and whole cells is related to the developments in miniature reactor technology and insights into flow behavior. Due to the high level of parallelization and reduced requirements of chemicals, intensive screening of biocatalysts and process variables has become more feasible and reproducibility of the bioconversion processes has been substantially improved. The present work aims to provide an overview of the applications of miniaturized reactors in bioconversion processes, considering multi-well plates and microfluidic devices, update information on the engineering characterization of the hardware used, and present perspective developments in this area of research.

  3. Liquid storage of miniature boar semen.

    Science.gov (United States)

    Shimatsu, Yoshiki; Uchida, Masaki; Niki, Rikio; Imai, Hiroshi

    2002-04-01

    The effects of liquid storage at 15 degrees C on the fertilizing ability of miniature pig semen were investigated. Characterization of ejaculated semen from 3 miniature boars was carried out. Semen volume and pH were similar among these boars. In one of the boars, sperm motility was slightly low, and sperm concentration and total number of sperm were significantly lower than in the others (P semen was substituted with various extenders (Kiev, Androhep, BTS and Modena) by centrifugation and semen was stored for 7 days at 15 degrees C. Sperm motility was estimated daily at 37 degrees C. For complete substitution of seminal plasma, Modena was significantly more efficient than the other extenders (P Semen from each of the 3 miniature boars that had been stored for 5 to 7 days at 15 degrees C in Modena was used for artificial insemination of 15 miniature sows. The farrowing rates were 100, 100 and 60%, and litter sizes were 6.4 +/- 1.5, 5.8 +/- 0.8 and 5.0 +/- 1.0 for each boar semen, respectively. The boar that sired the smallest farrowing rate was the same one that showed lower seminal quality with respect to sperm motility, sperm concentration and total number of sperm. These results suggest that miniature boar semen can be stored for at least 5 days at 15 degrees C by the substitution of seminal plasma with Modena extender.

  4. Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

    Science.gov (United States)

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-04-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  5. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    Directory of Open Access Journals (Sweden)

    Wook Jae Yoo

    2014-04-01

    Full Text Available A miniature fiber-optic dosimeter (FOD system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  6. TELEMETRY AND TELECOMMAND SYSTEM OF LOW-EARTH-ORBIT MICROSATELLITE, KITSAT-1 AND 2

    Directory of Open Access Journals (Sweden)

    Sungheon Kim

    1996-06-01

    Full Text Available The telecommand system of KITSAT micorsatellite receives commands from ground stations or on-board computers. It decodes, validates and delivers commands to sub-system. The telemetry system is to collect, process and format satellite housekeeping and mission data for use by on-board computer and ground station. It is crucial for the telemetry and telecommand system to have high reliability since the spacecraft operation is mostly based on the function of this system. The telemetry and telecommand(TTC systems for KITSAT-1 and 2 had been developed under the consideratin of the space environment of Low-Earth-Orbit and the limited mass, volume and power of micorsatellite. Since both satellites were launched in August 1992 and September 1993 respectively, the have shown to be working successfully as well as the TTC systems on-board both satellites.

  7. Information collection and processing of dam distortion in digital reservoir system

    Science.gov (United States)

    Liang, Yong; Zhang, Chengming; Li, Yanling; Wu, Qiulan; Ge, Pingju

    2007-06-01

    The "digital reservoir" is usually understood as describing the whole reservoir with digital information technology to make it serve the human existence and development furthest. Strictly speaking, the "digital reservoir" is referred to describing vast information of the reservoir in different dimension and space-time by RS, GPS, GIS, telemetry, remote-control and virtual reality technology based on computer, multi-media, large-scale memory and wide-band networks technology for the human existence, development and daily work, life and entertainment. The core of "digital reservoir" is to realize the intelligence and visibility of vast information of the reservoir through computers and networks. The dam is main building of reservoir, whose safety concerns reservoir and people's safety. Safety monitoring is important way guaranteeing the dam's safety, which controls the dam's running through collecting the dam's information concerned and developing trend. Safety monitoring of the dam is the process from collection and processing of initial safety information to forming safety concept in the brain. The paper mainly researches information collection and processing of the dam by digital means.

  8. Advances in miniature spectrometer and sensor development

    Science.gov (United States)

    Malinen, Jouko; Rissanen, Anna; Saari, Heikki; Karioja, Pentti; Karppinen, Mikko; Aalto, Timo; Tukkiniemi, Kari

    2014-05-01

    Miniaturization and cost reduction of spectrometer and sensor technologies has great potential to open up new applications areas and business opportunities for analytical technology in hand held, mobile and on-line applications. Advances in microfabrication have resulted in high-performance MEMS and MOEMS devices for spectrometer applications. Many other enabling technologies are useful for miniature analytical solutions, such as silicon photonics, nanoimprint lithography (NIL), system-on-chip, system-on-package techniques for integration of electronics and photonics, 3D printing, powerful embedded computing platforms, networked solutions as well as advances in chemometrics modeling. This paper will summarize recent work on spectrometer and sensor miniaturization at VTT Technical Research Centre of Finland. Fabry-Perot interferometer (FPI) tunable filter technology has been developed in two technical versions: Piezoactuated FPIs have been applied in miniature hyperspectral imaging needs in light weight UAV and nanosatellite applications, chemical imaging as well as medical applications. Microfabricated MOEMS FPIs have been developed as cost-effective sensor platforms for visible, NIR and IR applications. Further examples of sensor miniaturization will be discussed, including system-on-package sensor head for mid-IR gas analyzer, roll-to-roll printed Surface Enhanced Raman Scattering (SERS) technology as well as UV imprinted waveguide sensor for formaldehyde detection.

  9. Satellite telemetry of Afrotropical ducks: methodological details and ...

    African Journals Online (AJOL)

    Despite widespread and increasing use of solarpowered satellite transmitters to tag wild birds, there are few published articles that detail how transmitters should be attached to different species and even fewer assessments of the overall field success of telemetry projects. The scarcity of this information makes it difficult to ...

  10. Implementing telemetry on new species in remote areas ...

    African Journals Online (AJOL)

    We provide recommendations for implementing telemetry studies on waterfowl on the basis of our experience in a tracking study conducted in three countries of sub-Saharan Africa. The aim of the study was to document movements by duck species identified as priority candidates for the potential spread of avian influenza.

  11. Telemetry-based mortality estimates of juvenile spot in two North Carolina estuarine creeks

    Science.gov (United States)

    Friedl, Sarah E.; Buckel, Jeffery A.; Hightower, Joseph E.; Scharf, Frederick S.; Pollock, Kenneth H.

    2013-01-01

    We estimated natural mortality rates (M) of age-1 Spot Leiostomus xanthurus by using a sonic telemetry approach. Sonic transmitters were surgically implanted into a total of 123 age-1 Spot in two North Carolina estuarine creeks during spring 2009 and 2010, and the fish were monitored by using a stationary acoustic receiver array and manual tracking. Fates of telemetered Spot were inferred based on telemetry information from estimated locations and swimming speeds. Potential competitors of age-1 Spot were assessed through simultaneous otter trawl sampling, while potential predators of Spot were collected using gill nets and trammel nets. The number of inferred natural mortalities was zero in 2009 (based on 29 telemetered Spot at risk) and four in 2010 (based on 52 fish at risk), with fish being at risk for up to about 70 d each year. Catches of potential competitors or predators did not differ between years, and age-1 Spot were not found in analyzed stomach contents of potential predators. Our estimated 30-d M of 0.03 (95% credible interval = 0.01–0.07) was lower than that predicted from weight-based (M = 0.07) and life-history-based (M = 0.06–0.36) estimates. Our field-based estimate of M for age-1 Spot in this estuarine system can assist in the assessment and management of Spot by allowing a direct comparison with M-values predicted from fish size or life history characteristics. The field telemetry and statistical analysis techniques developed here provide guidance for future telemetry studies of relatively small fish in open, dynamic habitat systems, as they highlight strengths and weaknesses of using a telemetry approach to estimate M.

  12. Acoustic telemetry validates a citizen science approach for monitoring sharks on coral reefs.

    Science.gov (United States)

    Vianna, Gabriel M S; Meekan, Mark G; Bornovski, Tova H; Meeuwig, Jessica J

    2014-01-01

    Citizen science is promoted as a simple and cost-effective alternative to traditional approaches for the monitoring of populations of marine megafauna. However, the reliability of datasets collected by these initiatives often remains poorly quantified. We compared datasets of shark counts collected by professional dive guides with acoustic telemetry data from tagged sharks collected at the same coral reef sites over a period of five years. There was a strong correlation between the number of grey reef sharks (Carcharhinus amblyrhynchos) observed by dive guides and the telemetry data at both daily and monthly intervals, suggesting that variation in relative abundance of sharks was detectable in datasets collected by dive guides in a similar manner to data derived from telemetry at these time scales. There was no correlation between the number or mean depth of sharks recorded by telemetry and the presence of tourist divers, suggesting that the behaviour of sharks was not affected by the presence of divers during our study. Data recorded by dive guides showed that current strength and temperature were important drivers of the relative abundance of sharks at monitored sites. Our study validates the use of datasets of shark abundance collected by professional dive guides in frequently-visited dive sites in Palau, and supports the participation of experienced recreational divers as contributors to long-term monitoring programs of shark populations.

  13. Telemetry Boards Interpret Rocket, Airplane Engine Data

    Science.gov (United States)

    2009-01-01

    For all the data gathered by the space shuttle while in orbit, NASA engineers are just as concerned about the information it generates on the ground. From the moment the shuttle s wheels touch the runway to the break of its electrical umbilical cord at 0.4 seconds before its next launch, sensors feed streams of data about the status of the vehicle and its various systems to Kennedy Space Center s shuttle crews. Even while the shuttle orbiter is refitted in Kennedy s orbiter processing facility, engineers constantly monitor everything from power levels to the testing of the mechanical arm in the orbiter s payload bay. On the launch pad and up until liftoff, the Launch Control Center, attached to the large Vehicle Assembly Building, screens all of the shuttle s vital data. (Once the shuttle clears its launch tower, this responsibility shifts to Mission Control at Johnson Space Center, with Kennedy in a backup role.) Ground systems for satellite launches also generate significant amounts of data. At Cape Canaveral Air Force Station, across the Banana River from Kennedy s location on Merritt Island, Florida, NASA rockets carrying precious satellite payloads into space flood the Launch Vehicle Data Center with sensor information on temperature, speed, trajectory, and vibration. The remote measurement and transmission of systems data called telemetry is essential to ensuring the safe and successful launch of the Agency s space missions. When a launch is unsuccessful, as it was for this year s Orbiting Carbon Observatory satellite, telemetry data also provides valuable clues as to what went wrong and how to remedy any problems for future attempts. All of this information is streamed from sensors in the form of binary code: strings of ones and zeros. One small company has partnered with NASA to provide technology that renders raw telemetry data intelligible not only for Agency engineers, but also for those in the private sector.

  14. Wireless Power Transfer System for Rotary Parts Telemetry of Gas Turbine Engine

    Directory of Open Access Journals (Sweden)

    Xiaoming He

    2018-04-01

    Full Text Available A novel wireless power transfer approach for the rotary parts telemetry of a gas turbine engine is proposed. The advantages of a wireless power transfer (WPT system in the power supply for the rotary parts telemetry of a gas turbine engine are introduced. By simplifying the circuit of the inductively-coupled WPT system and developing its equivalent circuit model, the mathematical expressions of transfer efficiency and transfer power of the system are derived. A mutual inductance model between receiving and transmitting coils of the WPT system is presented and studied. According to this model, the mutual inductance between the receiving and the transmitting coils can be calculated at different axial distances. Then, the transfer efficiency and transfer power can be calculated as well. Based on the test data, the relationship of the different distances between the two coils, the transfer efficiency, and transfer power is derived. The proper positions where the receiving and transmitting coils are installed in a gas turbine engine are determined under conditions of satisfying the transfer efficiency and transfer power that the telemetry system required.

  15. Miniaturized GPS/MEMS IMU integrated board

    Science.gov (United States)

    Lin, Ching-Fang (Inventor)

    2012-01-01

    This invention documents the efforts on the research and development of a miniaturized GPS/MEMS IMU integrated navigation system. A miniaturized GPS/MEMS IMU integrated navigation system is presented; Laser Dynamic Range Imager (LDRI) based alignment algorithm for space applications is discussed. Two navigation cameras are also included to measure the range and range rate which can be integrated into the GPS/MEMS IMU system to enhance the navigation solution.

  16. Miniaturizing RFID for magnamosis.

    Science.gov (United States)

    Jiang, Hao; Chen, Shijie; Kish, Shad; Loh, Lokkee; Zhang, Junmin; Zhang, Xiaorong; Kwiat, Dillon; Harrison, Michael; Roy, Shuvo

    2014-01-01

    Anastomosis is a common surgical procedure using staples or sutures in an open or laparoscopic surgery. A more effective and much less invasive alternative is to apply the mechanical pressure on the tissue over a few days [1]. Since the pressure is produced by the attractive force between two permanent magnets, the procedure is called magnamosis[1]. To ensure the two magnets are perfectly aligned during the surgery, a miniaturized batteryless Radio Frequency IDentification (RFID) tag is developed to wirelessly telemeter the status of a pressure sensitive mechanical switch. Using the multi-layer circular spiral coil design, the diameter of the RFID tag is shrunk to 10, 15, 19 and 27 mm to support the magnamosis for children as well as adults. With the impedance matching network, the operating distance of these four RFID tags are longer than 10 cm in a 20 × 22 cm(2) area, even when the tag's normal direction is 45° off the antenna's normal direction. Measurement results also indicate that there is no noticeable degradation on the operating distance when the tag is immersed in saline or placed next to the rare-earth magnet. The miniaturized RFID tag presented in this paper is able to support the magnamosis and other medical applications that require the miniaturized RFID tag.

  17. Prototipe Sistem Telemetri Berbasis Sensor Suhu dan Sensor Asap untuk Pemantau Kebakaran Lahan

    Directory of Open Access Journals (Sweden)

    Boni Pahlanop Lapanporo

    2011-12-01

    Full Text Available Telah dilakukan perancangan suatu sistem telemetri berbasis  sensor suhu dan sensor asap (smoke detector untuk pemantau kebakaran lahan. Jenis sensor suhu yang digunakan adalah sensor LM35 dan Sensor asap yang digunakan tipe FG200. Untuk perangkat pengubah data analog keluaran sensor suhu dan sensor asap menjadi sinyal digital digunakan mikrokontroler ATMega8535. Pengiriman data menggunakan modul RF TXM02 pada bagian pemancar (transmitter dan modul FR RXM01 pada bagian penerima (receiver yang mampu melakukan transmisi data pada jarak 200 m di udara terbuka. Tampilan data keluaran hasil pembacaan sensor pada bagian pengirim dan bagian penerima selain dapat ditampilkan pada komputer dengan menggunakan GUI (Graphic User Interface dengan pemograman Borland Delphi 7.0, juga ditampilkan menggunakan LCD 16 x 2 character. Indikator terjadinya kebakaran (munculnya asap dan suhu lebih dari 37 °C tampak pada menyalanya alarm (buzzer yang terhubung dengan mikrokontroler. Hasil pengujian menunjukkan bahwa sistem dapat bekerja dengan baik di dalam melakukan pengiriman data informasi suhu dan keberadaan asap di titik pengamatan.

  18. An explosive acoustic telemetry system for seabed penetrators

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, G.C.; Hickerson, J.

    1988-04-01

    This report discusses the design and past applications of an explosive acoustic telemetry system (EATS) for gathering and transmitting data from seabed penetrators. The system was first fielded in 1982 and has since been used to measure penetrator performance on three other occasions. Descriptions are given of the mechanical hardware, system electronics, and software.

  19. Intraperitoneal implantation of life-long telemetry transmitters in otariids

    Directory of Open Access Journals (Sweden)

    Haulena Martin

    2008-12-01

    Full Text Available Abstract Background Pinnipeds, including many endangered and declining species, are inaccessible and difficult to monitor for extended periods using externally attached telemetry devices that are shed during the annual molt. Archival satellite transmitters were implanted intraperitoneally into four rehabilitated California sea lions (Zalophus californianus and 15 wild juvenile Steller sea lions (Eumetopias jubatus to determine the viability of this surgical technique for the deployment of long-term telemetry devices in otariids. The life history transmitters record information throughout the life of the host and transmit data to orbiting satellites after extrusion following death of the host. Results Surgeries were performed under isoflurane anesthesia and single (n = 4 or dual (n = 15 transmitters were inserted into the ventrocaudal abdominal cavity via an 8.5 to 12 cm incision along the ventral midline between the umbilicus and pubic symphysis or preputial opening. Surgeries lasted 90 minutes (SD = 8 for the 19 sea lions. All animals recovered well and were released into the wild after extended monitoring periods from 27 to 69 days at two captive animal facilities. Minimum post-implant survival was determined via post-release tracking using externally attached satellite transmitters or via opportunistic re-sighting for mean durations of 73.7 days (SE = 9.0, Z. californianus and 223.6 days (SE = 71.5, E. jubatus. Conclusion The low morbidity and zero mortality encountered during captive observation and post-release tracking periods confirm the viability of this surgical technique for the implantation of long-term telemetry devices in otariids.

  20. Data Stream Processing Study in a Multichannel Telemetry Data Registering System

    Directory of Open Access Journals (Sweden)

    I. M. Sidyakin

    2015-01-01

    Full Text Available The paper presents the results of research that is aimed to improve the reliability of transmission of telemetry information (TMI through a communication channel with noise from the object of telemeasurements to the telemetry system for collecting and processing data. It considers the case where the quality of received information changes over time, due to movement of the object relative to the receiving station, or other factors that cause changes in the characteristics of noise in the channel, up to the total loss due to some temporary sites. To improve the reliability of transmission and ensure continuous communication with the object, it is proposed to use a multi-channel system to record the TMI. This system consists of several telemetry stations, which simultaneously register data stream transmitted from the telemetry object. The multichannel system generates a single stream of TMI for the user at the output. The stream comprises the most reliable pieces of information, being received at all inputs of the system.The paper investigates the task of constructing a multi-channel registration scheme for telemetry information (TMI to provide a simultaneous reception of the telemeasurement data by multiple telemetry stations and to form a single TMI stream containing the most reliable pieces of received data on the basis of quality analysis of information being received.In a multichannel registering system of TMI there are three main factors affecting the quality of the output of a single stream of information: 1 quality of the method used for protecting against errors during transmission over the communication channel with noise; 2 efficiency of the synchronization process of telemetry frames in the received flow of information; 3 efficiency of the applied criteria to form a single output stream from multiple input streams coming from different stations in the discussed multichannel registering system of TMI.In the paper, in practical

  1. CCSDS telemetry systems experience at the Goddard Space Flight Center

    Science.gov (United States)

    Carper, Richard D.; Stallings, William H., III

    1990-01-01

    NASA Goddard Space Flight Center (GSFC) designs, builds, manages, and operates science and applications spacecraft in near-earth orbit, and provides data capture, data processing, and flight control services for these spacecraft. In addition, GSFC has the responsibility of providing space-ground and ground-ground communications for near-earth orbiting spacecraft, including those of the manned spaceflight programs. The goal of reducing both the developmental and operating costs of the end-to-end information system has led the GSFC to support and participate in the standardization activities of the Consultative Committee for Space Data Systems (CCSDS), including those for packet telemetry. The environment in which such systems function is described, and the GSFC experience with CCSDS packet telemetry in the context of the Gamma-Ray Observatory project is discussed.

  2. Evaluating CMA Equalization of SOQPSK-TG for Aeronautical Telemetry

    Science.gov (United States)

    2015-03-01

    Program through the U.S. Army Program Executive Office for Simulation, Training and Instrumentation (PEO STRI) under contract W900KK-13-C-0026 ( PAQ ...Report: Preamble assisted equalization for aeronautical telemetry ( PAQ ),‖ Brigham Young University, Technical Report, 2014, submitted to the Spectrum

  3. A Systematic Approach to Error Free Telemetry

    Science.gov (United States)

    2017-06-28

    FORCE BASE , CALIFORNIA AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE 4 1 2 T W This Technical Information Memorandum (412TW-TIM-17-03, A...INTRODUCTION The airborne telemetry channel between the test article and ground receiving station introduces impairments that distort the received signal...the airframe under certain airplane-to-ground station geometries can exist should only one transmit antenna be used. Conversely, using two transmit

  4. Miniature x-ray source

    Science.gov (United States)

    Trebes, James E.; Bell, Perry M.; Robinson, Ronald B.

    2000-01-01

    A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

  5. Miniature mass analyzer

    CERN Document Server

    Cuna, C; Lupsa, N; Cuna, S; Tuzson, B

    2003-01-01

    The paper presents the concept of different mass analyzers that were specifically designed as small dimension instruments able to detect with great sensitivity and accuracy the main environmental pollutants. The mass spectrometers are very suited instrument for chemical and isotopic analysis, needed in environmental surveillance. Usually, this is done by sampling the soil, air or water followed by laboratory analysis. To avoid drawbacks caused by sample alteration during the sampling process and transport, the 'in situ' analysis is preferred. Theoretically, any type of mass analyzer can be miniaturized, but some are more appropriate than others. Quadrupole mass filter and trap, magnetic sector, time-of-flight and ion cyclotron mass analyzers can be successfully shrunk, for each of them some performances being sacrificed but we must know which parameters are necessary to be kept unchanged. To satisfy the miniaturization criteria of the analyzer, it is necessary to use asymmetrical geometries, with ion beam obl...

  6. Geostationary Communications Satellites as Sensors for the Space Weather Environment: Telemetry Event Identification Algorithms

    Science.gov (United States)

    Carlton, A.; Cahoy, K.

    2015-12-01

    Reliability of geostationary communication satellites (GEO ComSats) is critical to many industries worldwide. The space radiation environment poses a significant threat and manufacturers and operators expend considerable effort to maintain reliability for users. Knowledge of the space radiation environment at the orbital location of a satellite is of critical importance for diagnosing and resolving issues resulting from space weather, for optimizing cost and reliability, and for space situational awareness. For decades, operators and manufacturers have collected large amounts of telemetry from geostationary (GEO) communications satellites to monitor system health and performance, yet this data is rarely mined for scientific purposes. The goal of this work is to acquire and analyze archived data from commercial operators using new algorithms that can detect when a space weather (or non-space weather) event of interest has occurred or is in progress. We have developed algorithms, collectively called SEER (System Event Evaluation Routine), to statistically analyze power amplifier current and temperature telemetry by identifying deviations from nominal operations or other events and trends of interest. This paper focuses on our work in progress, which currently includes methods for detection of jumps ("spikes", outliers) and step changes (changes in the local mean) in the telemetry. We then examine available space weather data from the NOAA GOES and the NOAA-computed Kp index and sunspot numbers to see what role, if any, it might have played. By combining the results of the algorithm for many components, the spacecraft can be used as a "sensor" for the space radiation environment. Similar events occurring at one time across many component telemetry streams may be indicative of a space radiation event or system-wide health and safety concern. Using SEER on representative datasets of telemetry from Inmarsat and Intelsat, we find events that occur across all or many of

  7. Liquid Robotics Wave Glider, Honey Badger (G3), 2015, Telemetry

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Liquid Robotics Wave Glider, Honey Badger (G3), 2015, Telemetry. The MAGI mission is to use the Wave Glider to sample the late summer chlorophyll bloom that develops...

  8. A microcontroller-based telemetry system for sympathetic nerve activity and ECG measurement.

    Science.gov (United States)

    Harada, E; Yonezawa, Y; Caldwell, W M; Hahn, A W

    1999-01-01

    A telemetry system employing a low power 8-bit microcontroller has been developed for chronic unanesthetized small animal studies. The two-channel system is designed for use with animals in shielded cages. Analog signals from implantable ECG and nerve electrodes are converted to an 8-bit serial digital format. This is accomplished by individual 8 bit A/D converters included in the microcontroller, which also has serial I/O port. The converted serial binary code is applied directly to an antenna wire. Therefore, the system does not need to employ a separate transmitter, such as in FM or infrared optical telemeters. The system is used in a shielded animal cage to reduce interference from external radio signals and 60 Hz power line fields. The code is received by a high input impedance amplifier in the cage and is then demodulated. The telemeter is powered by a small 3 V lithium battery, which provides 100 hours of continuous operation. The circuit is constructed on two 25 x 25 mm. printed circuit boards and encapsulated in epoxy, yielding a total volume of 6.25 cc. The weight is 15 g.

  9. Novel lipoprotein density profiling in healthy dogs of various breeds, healthy miniature schnauzers, and miniature schnauzers with hyperlipidemia

    Science.gov (United States)

    2013-01-01

    Background Despite the importance of abnormalities in lipoprotein metabolism in clinical canine medicine, the fact that most previously used methods for lipoprotein profiling are rather laborious and time-consuming has been a major obstacle to the wide clinical application and use of lipoprotein profiling in this species. The aim of the present study was to assess the feasibility of a continuous lipoprotein density profile (CLPDP) generated within a bismuth sodium ethylenediaminetetraacetic acid (NaBiEDTA) density gradient to characterize and compare the lipoprotein profiles of healthy dogs of various breeds, healthy Miniature Schnauzers, and Miniature Schnauzers with primary hypertriacylglycerolemia. A total of 35 healthy dogs of various breeds with serum triacylglycerol (TAG) and cholesterol concentrations within their respective reference intervals were selected for use as a reference population. Thirty-one Miniature Schnauzers with serum TAG and cholesterol concentrations within their respective reference intervals and 31 Miniature Schnauzers with hypertriacylglyceridemia were also included in the study. Results The results suggest that CLPDP using NaBiEDTA provides unique diagnostic information in addition to measurements of serum TAG and cholesterol concentrations and that it is a useful screening method for dogs with suspected lipoprotein metabolism disorders. Using the detailed and continuous density distribution information provided by the CLPDP, important differences in lipoprotein profiles can be detected even among dogs that have serum TAG and cholesterol concentrations within the reference interval. Miniature Schnauzers with serum TAG and cholesterol concentrations within the reference interval had significantly different lipoprotein profiles than dogs of various other breeds. In addition, it was further established that specific lipoprotein fractions are associated with hypertriacylglyceridemia in Miniature Schnauzers. Conclusions The results of the

  10. Miniature Scroll Pumps Fabricated by LIGA

    Science.gov (United States)

    Wiberg, Dean; Shcheglov, Kirill; White, Victor; Bae, Sam

    2009-01-01

    Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.

  11. Bidirectional Telemetry Controller for Neuroprosthetic Devices

    Science.gov (United States)

    Sharma, Vishnu; McCreery, Douglas B.; Han, Martin; Pikov, Victor

    2010-01-01

    We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s, allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes ∼420 mW and operates without recharge for 8 h. It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 μs after the end of the stimulus pulse applied in the cochlear nucleus. PMID:19933010

  12. Bidirectional telemetry controller for neuroprosthetic devices.

    Science.gov (United States)

    Sharma, Vishnu; McCreery, Douglas B; Han, Martin; Pikov, Victor

    2010-02-01

    We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s , allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes approximately 420 mW and operates without recharge for 8 h . It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 mus after the end of the stimulus pulse applied in the cochlear nucleus.

  13. Techniques for Fault Detection and Visualization of Telemetry Dependence Relationships for Root Cause Fault Analysis in Complex Systems

    Science.gov (United States)

    Guy, Nathaniel

    This thesis explores new ways of looking at telemetry data, from a time-correlative perspective, in order to see patterns within the data that may suggest root causes of system faults. It was thought initially that visualizing an animated Pearson Correlation Coefficient (PCC) matrix for telemetry channels would be sufficient to give new understanding; however, testing showed that the high dimensionality and inability to easily look at change over time in this approach impeded understanding. Different correlative techniques, combined with the time curve visualization proposed by Bach et al (2015), were adapted to visualize both raw telemetry and telemetry data correlations. Review revealed that these new techniques give insights into the data, and an intuitive grasp of data families, which show the effectiveness of this approach for enhancing system understanding and assisting with root cause analysis for complex aerospace systems.

  14. FY 2006 Miniature Spherical Retroreflectors Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, Norman C.; Bernacki, Bruce E.; Krishnaswami, Kannan

    2006-12-28

    Research done by the Infrared Photonics team at Pacific Northwest National Laboratory (PNNL) is focused on developing miniature spherical retroreflectors using the unique optical and material properties of chalcogenide glass to reduce both performance limiting spherical aberrations. The optimized optical performance will provide efficient signal retroreflection that enables a broad range of remote detection scenarios for mid-wave infrared (MWIR) and long-wave infrared (LWIR) sensing applications. Miniature spherical retroreflectors can be developed to aid in the detection of signatures of nuclear proliferation or other chemical vapor or radiation signatures. Miniature spherical retroreflectors are not only well suited to traditional LIDAR methods for chemical plume detection and identification, but could enable remote detection of difficult semi-volatile chemical materials or low level radiation sources.

  15. Acoustic telemetry reveals cryptic residency of whale sharks

    KAUST Repository

    Cagua, Edgar F.

    2015-04-01

    Althoughwhale sharks (Rhincodon typus) have beendocumentedtomove thousands of kilometres, they are most frequently observed at a few predictable seasonal aggregation sites. The absence of sharks at the surface during visual surveys has led to the assumption that sharks disperse to places unknown during the long \\'off-seasons\\' at most of these locations. Here we compare 2 years of R. typus visual sighting records from Mafia Island in Tanzania to concurrent acoustic telemetry of tagged individuals. Sightings revealed a clear seasonal pattern with a peak between October and February and no sharks observed at other times. By contrast, acoustic telemetry demonstrated yearround residency of R. typus. The sharks use a different habitat in the offseason, swimming deeper and further away from shore, presumably in response to prey distributions. This behavioural change reduces the sharks\\' visibility, giving the false impression that they have left the area.We demonstrate, for the first timeto our knowledge, year-roundresidencyofunprovisioned, individual R. typus at an aggregation site, and highlight the importance of using multiple techniques to study the movement ecology of marine megafauna. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  16. Real-time monitoring of seismic data using satellite telemetry

    Directory of Open Access Journals (Sweden)

    L. Merucci

    1997-06-01

    Full Text Available This article describes the ARGO Satellite Seismic Network (ARGO SSN as a reliable system for monitoring, collection, visualisation and analysis of seismic and geophysical low-frequency data, The satellite digital telemetry system is composed of peripheral geophysical stations, a centraI communications node (master sta- tion located in CentraI Italy, and a data collection and processing centre located at ING (Istituto Nazionale di Geofisica, Rome. The task of the peripheral stations is to digitalise and send via satellite the geophysical data collected by the various sensors to the master station. The master station receives the data and forwards them via satellite to the ING in Rome; it also performs alI the monitoring functions of satellite communications. At the data collection and processing centre of ING, the data are received and analysed in real time, the seismic events are identified and recorded, the low-frequency geophysical data are stored. In addition, the generaI sta- tus of the satellite network and of each peripheral station connected, is monitored. The procedure for analysjs of acquired seismic signals allows the automatic calculation of local magnitude and duration magnitude The communication and data exchange between the seismic networks of Greece, Spain and Italy is the fruit of a recent development in the field of technology of satellite transmission of ARGO SSN (project of European Community "Southern Europe Network for Analysis of Seismic Data"

  17. iSAT: The Integrated Satellite and Acoustic Telemetry system for tracking marine megafauna

    KAUST Repository

    De La Torre, Pedro R.

    2014-05-01

    In this dissertation an innovative technology to study whale sharks, Rhincodon typus is presented. The Integrated Satellite and Acoustic Telemetry project (iSAT) combines underwater acoustic telemetry, autonomous navigation and radio frequency communications into a standalone system. The whale shark, a resident of the Saudi Arabian Red Sea, is the target of the study. The technology presented is designed to help close current gaps in the knowledge of whale shark biology; these are gaps that prohibit the design of optimal conservation strategies. Unfortunately, the various existing tracking technologies each have limitations and are unable to solve all the unanswered questions. Whale shark populations are increasingly threatened by anthropogenic activities such as targeted and indirect fishing pressure, creating an urgent need for better management practices. This dissertation addresses the current state-of-the-art of relevant technologies, including autonomous surface vehicles (ASVs), sensors for research in the ocean and remote monitoring of wild fauna (biotelemetry). iSAT contains components of all of these technologies, but the primary achievement of this dissertation is the development of iSAT’s Acoustic Tracking System (ATS). Underwater, the most efficient way of transmitting energy through long distances is sound. An electronic tag is attached to an animal and works as its acoustic identifier. iSAT’s hydrophone array detects the presence and direction of the acoustic signal generated by the tag. The expected performance, range, and capacity to tell the direction to the tag are explained and compared to the actual measured values. The first operational iSAT ATS is demonstrated. This work represents significant advancement towards a fully autonomous iSAT system. Developments on the power electronics, navigation, renewable energy harvesting, and other modules are included in this research. With the recent integration of digital acquisition systems, i

  18. Presynaptic miniature GABAergic currents in developing interneurons.

    Science.gov (United States)

    Trigo, Federico F; Bouhours, Brice; Rostaing, Philippe; Papageorgiou, George; Corrie, John E T; Triller, Antoine; Ogden, David; Marty, Alain

    2010-04-29

    Miniature synaptic currents have long been known to represent random transmitter release under resting conditions, but much remains to be learned about their nature and function in central synapses. In this work, we describe a new class of miniature currents ("preminis") that arise by the autocrine activation of axonal receptors following random vesicular release. Preminis are prominent in gabaergic synapses made by cerebellar interneurons during the development of the molecular layer. Unlike ordinary miniature postsynaptic currents in the same cells, premini frequencies are strongly enhanced by subthreshold depolarization, suggesting that the membrane depolarization they produce belongs to a feedback loop regulating neurotransmitter release. Thus, preminis could guide the formation of the interneuron network by enhancing neurotransmitter release at recently formed synaptic contacts. Copyright 2010 Elsevier Inc. All rights reserved.

  19. Alaska northern fur seal adult male satellite telemetry data, 2009-2010

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set is comprised of satellite-linked telemetry data collected to investigate winter migration patterns and foraging strategies of adult male northern fur...

  20. Telemetry with an Optical Fiber Revisited: An Alternative Strategy

    Science.gov (United States)

    Kraftmakher, Yaakov

    2014-01-01

    With a new data-acquisition system developed by PASCO scientific, an experiment on telemetry with an optical fiber can be made easier and more accurate. For this aim, an alternative strategy of the remote temperature measurements is proposed: the frequency of light pulses transmitted via the light guide numerically equals the temperature using…

  1. Software Defined Multiband EVA Radio, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of Phase 2 is to build a reliable, lightweight, programmable, multi-mode, miniaturized EVA Software Defined Radio (SDR) that supports data telemetry,...

  2. Ocean Surface Topography Mission (OSTM) /Jason-2: Telemetry (NODC Accession 0044986)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This accession contains the data descriptions for the OSTM/Jason-2 Telemetry data, which is served through the NOAA/NESDIS Comprehensive Large Array-data Stewardship...

  3. Miniature Centrifugal Compressor

    Science.gov (United States)

    Sixsmith, Herbert

    1989-01-01

    Miniature turbocompressor designed for reliability and long life. Cryogenic system includes compressor, turboexpander, and heat exchanger provides 5 W of refrigeration at 70 K from 150 W input power. Design speed of machine 510,000 rpm. Compressor has gas-lubricated journal bearings and magnetic thrust bearing. When compressor runs no bearing contact and no wear.

  4. Goniometry and Limb Girth in Miniature Dachshunds

    OpenAIRE

    Thomovsky, Stephanie A.; Chen, Annie V.; Kiszonas, Alecia M.; Lutskas, Lori A.

    2016-01-01

    Purpose. To report the mean and median pelvic limb joint angles and girth measurements in miniature Dachshunds presenting with varying degrees of pelvic limb weakness secondary to thoracolumbar intervertebral disc extrusion. Methods. 15 miniature Dachshunds who presented to WSU-VTH for thoracolumbar disc extrusion. Dachshunds varied in neurologic status from ambulatory paraparetic to paraplegic at the time of measurements. Results. There were no significant differences in joint angles or girt...

  5. Miniaturized Environmental Monitoring Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    C. B. Freidhoff

    1997-09-01

    The objective of the Mass Spectrograph on a Chip (MSOC) program is the development of a miniature, multi-species gas sensor fabricated using silicon micromachining technology which will be orders of magnitude smaller and lower power consumption than a conventional mass spectrometer. The sensing and discrimination of this gas sensor are based on an ionic mass spectrograph, using magnetic and/or electrostatic fields. The fields cause a spatial separation of the ions according to their respective mass-to-charge ratio. The fabrication of this device involves the combination of microelectronics with micromechanically built sensors and, ultimately, vacuum pumps. The prototype of a chemical sensor would revolutionize the method of performing environmental monitoring for both commercial and government applications. The portable unit decided upon was the miniaturized gas chromatograph with a mass spectrometer detector, referred to as a GC/MS in the analytical marketplace.

  6. Antenna Miniaturization with MEMS Tunable Capacitors

    DEFF Research Database (Denmark)

    Barrio, Samantha Caporal Del; Morris, Art; Pedersen, Gert Frølund

    2014-01-01

    In today’s mobile device market, there is a strong need for efficient antenna miniaturization. Tunable antennas are a very promising way to reduce antenna volume while enlarging its operating bandwidth. MEMS tunable capacitors are state-ofthe- art in terms of insertion loss and their characterist......In today’s mobile device market, there is a strong need for efficient antenna miniaturization. Tunable antennas are a very promising way to reduce antenna volume while enlarging its operating bandwidth. MEMS tunable capacitors are state-ofthe- art in terms of insertion loss...

  7. Instrumentation and Baseband Telemetry for RLV-TD HEX Mission

    Science.gov (United States)

    Jose, Smitha; Varghese, Bibin; Chauhan, Akshay; Elizabeth, Sheba; Sreelal, S.; Sreekumar, S.; Vinod, P.; Mookiah, T.

    2017-12-01

    In this work, the salient requirements and features of the baseband telemetry system used in Reusable Launch Vehicle—Technology Demonstrator Hypersonic Experiment mission are discussed. The configuration of the overall system, subsystem components and their features are described in brief. The unique requirements of the telemetry system, when compared to that in a conventional launch vehicle, by way of a large number of temperature and strain measurements that enable the assessment of structural integrity and mission performance in re-entry mission, are dealt with, along with the system configuration to cater to these. Subsequently, two new units have been described—Strain Data Acquisition Unit and Multiplexed Data Acquisition Unit that were inducted specifically to cater to strain measurements using strain gauges and temperature measurements using thermocouples respectively. The optimized subsystem configurations for these units are described and their field performance during flight is analyzed. This work further discusses a novel method of data recovery for those measurements affected by the baseline offset shift caused by the presence of a chassis voltage and poor isolation of sensor to chassis.

  8. Evaluation of three telemetry transmitter attachment methods for female silver-phase American eels ( Anguilla rostrata Lesueur)

    DEFF Research Database (Denmark)

    Cottrill, R.A.; Økland, F.; Aarestrup, Kim

    2006-01-01

    Declines in juvenile American eel (Anguilla rostrata Lesueur) abundance have led to concern about the impacts of anthropogenic structures on eel migration patterns. Telemetry provides an insightful tool for examining the movements of eels around these structures. Although there have been a number...... of studies investigating movements of Anguillid eels, using a variety of transmitter attachment techniques, there are few published evaluations of the effects of various tag attachment procedures. Hence, the effects of three telemetry attachment procedures were evaluated for female silver phase American eels...... of silver-phase American eels is not affected by the presence of telemetry transmitters or the method of transmitter attachment, even though swim performance decreases. However, transmitter retention rates varied considerably after the 12-week experimental period. Three gastric tags were regurgitated...

  9. 47 CFR 95.1119 - Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band.

    Science.gov (United States)

    2010-10-01

    ... devices operating in the 608-614 MHz band. For a wireless medical telemetry device operating within the... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band. 95.1119 Section 95.1119 Telecommunication FEDERAL...

  10. Research on Miniature Calibre Rail-Guns for the Mechanical Arm

    Directory of Open Access Journals (Sweden)

    Ronggang Cao

    2017-01-01

    Full Text Available Rail-gun should not only be used to military applications, but also can be developed as applications in the civilian aspects of the market. With the development of the electromagnetic launch technology, based on the similarity theory, using the existing rail-gun model to guide the construction of more economical miniature calibre rail-guns, and apply it in some machinery and equipment, this idea will open up a wider rail-gun application space. This article will focus on the feasibility of application of miniature calibre rail-guns in the mechanical arm. This paper designs the schematic diagram, then theoretical analyzes force conditions of the armature in the mechanical arm, calculates the possible range of the current amplitude and so on. The existing rail-gun model can be used to guides design the circuit diagram of the miniature calibre rail-gun. Based on the similarity theory and many simulation experiments, designed the experimental parameters of a miniature rail-gun and analyzed the current, Lorentz force, velocity, and location of the existing rail-gun and miniature rail-gun. The results show that the rail-gun launching technology applied to robot arms is feasibility. The application of miniature calibre rail-guns in the mechanical arm will benefit to the further development of rail-guns.

  11. 47 CFR 95.1121 - Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427...

    Science.gov (United States)

    2010-10-01

    ... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...

  12. Miniature Optical Isolator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — To address NASA's need for compact optical isolators, Physical Optics Corporation (POC) proposes to continue the development of a new Miniature Optical Isolator...

  13. Continuous flow nitration in miniaturized devices

    Directory of Open Access Journals (Sweden)

    Amol A. Kulkarni

    2014-02-01

    Full Text Available This review highlights the state of the art in the field of continuous flow nitration with miniaturized devices. Although nitration has been one of the oldest and most important unit reactions, the advent of miniaturized devices has paved the way for new opportunities to reconsider the conventional approach for exothermic and selectivity sensitive nitration reactions. Four different approaches to flow nitration with microreactors are presented herein and discussed in view of their advantages, limitations and applicability of the information towards scale-up. Selected recent patents that disclose scale-up methodologies for continuous flow nitration are also briefly reviewed.

  14. Goniometry and Limb Girth in Miniature Dachshunds

    Directory of Open Access Journals (Sweden)

    Stephanie A. Thomovsky

    2016-01-01

    Full Text Available Purpose. To report the mean and median pelvic limb joint angles and girth measurements in miniature Dachshunds presenting with varying degrees of pelvic limb weakness secondary to thoracolumbar intervertebral disc extrusion. Methods. 15 miniature Dachshunds who presented to WSU-VTH for thoracolumbar disc extrusion. Dachshunds varied in neurologic status from ambulatory paraparetic to paraplegic at the time of measurements. Results. There were no significant differences in joint angles or girth among the three groups (ambulatory paraparetic, nonambulatory paraparetic, or paraplegic (P>0.05. When group was disregarded and values for extension, flexion, and girth combined, no differences existed. Conclusions. Goniometry and limb girth measurements can successfully be made in the miniature Dachshund; however, the shape of the Dachshund leg makes obtaining these values challenging. There were no differences in joint angle or girth measurements between dogs with varying neurologic dysfunction at the time of measurement.

  15. Goniometry and Limb Girth in Miniature Dachshunds.

    Science.gov (United States)

    Thomovsky, Stephanie A; Chen, Annie V; Kiszonas, Alecia M; Lutskas, Lori A

    2016-01-01

    Purpose. To report the mean and median pelvic limb joint angles and girth measurements in miniature Dachshunds presenting with varying degrees of pelvic limb weakness secondary to thoracolumbar intervertebral disc extrusion. Methods. 15 miniature Dachshunds who presented to WSU-VTH for thoracolumbar disc extrusion. Dachshunds varied in neurologic status from ambulatory paraparetic to paraplegic at the time of measurements. Results. There were no significant differences in joint angles or girth among the three groups (ambulatory paraparetic, nonambulatory paraparetic, or paraplegic) (P > 0.05). When group was disregarded and values for extension, flexion, and girth combined, no differences existed. Conclusions. Goniometry and limb girth measurements can successfully be made in the miniature Dachshund; however, the shape of the Dachshund leg makes obtaining these values challenging. There were no differences in joint angle or girth measurements between dogs with varying neurologic dysfunction at the time of measurement.

  16. Acoustic telemetry reveals cryptic residency of whale sharks.

    Science.gov (United States)

    Cagua, E Fernando; Cochran, Jesse E M; Rohner, Christoph A; Prebble, Clare E M; Sinclair-Taylor, Tane H; Pierce, Simon J; Berumen, Michael L

    2015-04-01

    Although whale sharks (Rhincodon typus) have been documented to move thousands of kilometres, they are most frequently observed at a few predictable seasonal aggregation sites. The absence of sharks at the surface during visual surveys has led to the assumption that sharks disperse to places unknown during the long 'off-seasons' at most of these locations. Here we compare 2 years of R. typus visual sighting records from Mafia Island in Tanzania to concurrent acoustic telemetry of tagged individuals. Sightings revealed a clear seasonal pattern with a peak between October and February and no sharks observed at other times. By contrast, acoustic telemetry demonstrated year-round residency of R. typus. The sharks use a different habitat in the off-season, swimming deeper and further away from shore, presumably in response to prey distributions. This behavioural change reduces the sharks' visibility, giving the false impression that they have left the area. We demonstrate, for the first time to our knowledge, year-round residency of unprovisioned, individual R. typus at an aggregation site, and highlight the importance of using multiple techniques to study the movement ecology of marine megafauna. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  17. Translocation and radio-telemetry monitoring of pygmy marmoset, Cebuella pygmaea (Spix, 1823, in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    CAR. Dias

    Full Text Available Two groups of pygmy marmoset (Cebuella pygmaea were rescued along the left bank of the Madeira River during the formation of Santo Antônio Hydroelectric Dam reservoir in the state of Rondônia, Northern Brazil. Reintroduction of both groups occurred in areas of open Tropical rainforest located within the project´s Permanent Preservation Area. A post-release monitoring was conducted for three months using radio-telemetry. Individuals of each group remained together and settled in stable home ranges near their respective release sites. The mortality rate of translocated animals was about 7%. This seems to be the first report documenting the complete group translocation of C. pygmaea and the first to successfully employ radio-telemetry techniques in monitoring this species. This study demonstrated the feasibility of translocation and the use of radio-telemetry in monitoring C. pygmaea.

  18. Pricing of miniature vehicles made from telephone card waste

    Science.gov (United States)

    Puspitasari, N. B.; Pujotomo, D.; Muhardiansyah, H.

    2017-12-01

    The number of electronic devices in Indonesia in the last 10 years has been increasing quite drastically which contributes to more electronic waste. E-waste or electronic waste have different characteristics from other kinds of waste. Components of electronic waste often poisonous, consisting dangerous chemicals. The telephone card wasted is also an electronic waste. One alternative to handle and manage telephone card waste is to recycle it into collectible miniature vehicles. But the price of these miniatures is quite high, causing low interest in buying them. A research on the price of miniature vehicles in relation to consumers’ Ability to Pay (ATP) and Willingness to Pay (WTP) needs to be done. Segmentation analysis data, target, product positioning and product marketing mix are needed before commencing the research. Data collection is done through a survey by spreading questionnaire to 100 miniature vehicle collectors in Semarang, questioning their ability and willingness to pay recycled miniature vehicles. Calculations showed average ATP of Rp.112.520, 24 and average WTP of Rp.76.870. The last result showed the estimate pricing according to ATP and WTP which is Rp.66.000 with 58% of the respondents claiming to be willing and able to pay that price.

  19. Miniature UAVs : An overview

    NARCIS (Netherlands)

    Weimar, P.W.L.; Kerkkamp, J.S.F.; Wiel, R.A.N.; Meiller, P.P.; Bos, J.G.H.

    2014-01-01

    With this book TNO provides an overview of topics related to Miniature Unmanned Aerial Vehicles (MUAVs). Both novices and experts may find this publication valuable. The Netherlands Organisation for Applied Scientific Research TNO conducts research on UAVs and MUAVs, see for example [1], on the

  20. Designing marine fishery reserves using passive acoustic telemetry

    OpenAIRE

    Glazer, Robert A.; Delgado, Gabriel A.

    2006-01-01

    Marine Fishery Reserves (MFRs) are being adopted, in part, as a strategy to replenish depleted fish stocks and serve as a source for recruits to adjacent fisheries. By necessity, their design must consider the biological parameters of the species under consideration to ensure that the spawning stock is conserved while simultaneously providing propagules for dispersal. We describe how acoustic telemetry can be employed to design effective MFRs by elucidating important life-history parameters o...

  1. Radiation from ingested wireless devices in bio-medical telemetry bands

    OpenAIRE

    Chirwa, L.C.; Roy, S.; Cumming, D.R.S.

    2003-01-01

    The performance of wireless devices, using electrically small antennae, in the human intestine is investigated using the finite difference time domain method in recommended biomedical device telemetry bands. The radiation field intensity was found to depend on position but more strongly on frequency, with a transmission peak at 650 MHz.

  2. Femtosecond laser-assisted cataract surgery and implantable miniature telescope

    Directory of Open Access Journals (Sweden)

    Randal Pham

    2017-09-01

    Conclusions and importance: To our knowledge and confirmed by the manufacturer of the implantable miniature telescope this is the first case ever reported of a patient who has undergone femtosecond laser cataract surgery with corneal astigmatism correction and implantation of the implantable miniature telescope. This is also the first case report of the preoperative use of microperimetry and visual electrophysiology to evaluate a patient's postoperative potential visual acuity. The success of the procedure illustrated the importance of meticulous preoperative planning, the combined use of state-of-the-art technologies and the seamless teamwork in order to achieve the best clinical outcome for patients who undergo implantation of the implantable miniature telescope.

  3. Advanced Biotelemetry Systems for Space Life Sciences: PH Telemetry

    Science.gov (United States)

    Hines, John W.; Somps, Chris; Ricks, Robert; Kim, Lynn; Connolly, John P. (Technical Monitor)

    1995-01-01

    The SENSORS 2000! (S2K!) program at NASA's Ames Research Center is currently developing a biotelemetry system for monitoring pH and temperature in unrestrained subjects. This activity is part of a broader scope effort to provide an Advanced Biotelemetry System (ABTS) for use in future space life sciences research. Many anticipated research endeavors will require biomedical and biochemical sensors and related instrumentation to make continuous inflight measurements in a variable-gravity environment. Since crew time is limited, automated data acquisition, data processing, data storage, and subject health monitoring are required. An automated biochemical and physiological data acquisition system based on non invasive or implantable biotelemetry technology will meet these requirements. The ABTS will ultimately acquire a variety of physiological measurands including temperature, biopotentials (e.g. ECG, EEG, EMG, EOG), blood pressure, flow and dimensions, as well as chemical and biological parameters including pH. Development activities are planned in evolutionary, leveraged steps. Near-term activities include 1) development of a dual channel pH/temperature telemetry system, and 2) development of a low bandwidth, 4-channel telemetry system, that measures temperature, heart rate, pressure, and pH. This abstract describes the pH/temperature telemeter.

  4. Florida Atlantic Coast Telemetry (FACT) Array: A Working Partnership

    Science.gov (United States)

    Scheidt, Douglas; Ault, Erick; Ellis, Robert D.; Gruber, Samuel; Iafrate, Joseph; Kalinowsky, Chris; Kessel, Steven; Reyier, Eric; Snyder, David; Watwood, Stephanie; hide

    2015-01-01

    The Florida Atlantic Coast Telemetry (FACT) Array is a collaborative partnership of researchers from 24 different organizations using passive acoustic telemetry to document site fidelity, habitat preferences, seasonal migration patterns, and reproductive strategies of valuable sportfish, sharks, and marine turtles. FACT partners have found that by bundling resources, they can leverage a smaller investment to track highly mobile animals beyond a study area typically restrained in scale by funds and manpower. FACT is guided by several simple rules: use of the same type of equipment, locate receivers in areas that are beneficial to all researchers when feasible, maintain strong scientific ethics by recognizing that detection data on any receiver belongs to the tag owner, do not use other members detection data without permission and acknowledge FACT in publications. Partners have access to a network of 480 receivers deployed along a continuum of habitats from freshwater rivers to offshore reefs and covers 1100 km of coastline from the Dry Tortugas, Florida to South Carolina and extends to the Bahamas. Presently, 49 species, (25 covered by Fisheries Management Plans and five covered by the Endangered Species Act) have been tagged with 2736 tags in which 1767 tags are still active.

  5. Gradual Changes of Gut Microbiota in Weaned Miniature Piglets

    Directory of Open Access Journals (Sweden)

    Xianghua Yan

    2016-11-01

    Full Text Available Colonization of gut microbiota in mammals during the early life is vital to host health. The miniature piglet has recently been considered as an optimal infant model. However, less is known about the development of gut microbiota in miniature piglets. Here, this study was conducted to explore how the gut microbiota develops in weaned Congjiang miniature piglets. In contrast to the relatively stabilized gut fungal community, gut bacterial community showed a marked drop in alpha diversity, accompanied by significant alterations in taxonomic compositions. The relative abundances of 24 bacterial genera significantly declined, whereas the relative abundances of 7 bacterial genera (Fibrobacter, Collinsella, Roseburia, Prevotella, Dorea, Howardella, and Blautia significantly increased with the age of weaned piglets. Fungal taxonomic analysis showed that the relative abundances of 2 genera (Kazachstania and Aureobasidium significantly decreased, whereas the relative abundances of 4 genera (Aspergillus, Cladosporium, Simplicillium, and Candida significantly increased as the piglets aged. Kazachstania telluris was the signature species predominated in gut fungal communities of weaned miniature piglets. The functional maturation of the gut bacterial community was characterized by the significantly increased digestive system, glycan biosynthesis and metabolism, and vitamin B biosynthesis as the piglets aged. These findings suggest that marked gut microbial changes in Congjiang miniature piglets may contribute to understand the potential gut microbiota development of weaned infants.

  6. An Automatic and Real-time Restoration of Gamma Dose Data by Radio Telemetry

    International Nuclear Information System (INIS)

    Lee, Wan No; Kim, Hee Reyoung; Chung, Kun Ho; Cho, Young Hyun; Choi, Geun Sik; Lee, Chang Woo; Kim, Young Soo

    2006-01-01

    On-line gamma monitoring system based on a high pressurized ionization chamber has been used for determining airborne doses surrounding HANARO research reactor at KAERI (Korea Atomic Energy Research Institute). It is composed of a network of six monitoring stations and an on-line computer system. It has been operated by radio telemetry with a radio frequency of 468.8 MHz, which is able to transmit the real-time dose data measured from a remote ion chamber to the central computer for ten seconds-to seconds. Although radio telemetry has several advantages such as an effective and economical transmission, there is one main problem that data loss happen because each monitoring post only stores 300 radiation data points, which covers the previous sequential data of 50 minutes from the present in the case of a recording interval time of 10 seconds It is possible to restore the lost data by an off-line process such as a floppy disk or portable memory disk but it is ineffective method at the real-time monitoring system. Restoration, storage, and display of the current data as well as the lost data are also difficult in the present system. In this paper, an automatic and real-time restoration method by radio telemetry will be introduced

  7. Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

    Science.gov (United States)

    McBride, M. J.; Williams, David R.; Hills, H. Kent

    2012-01-01

    We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

  8. Communication strategies and timeliness of response to life critical telemetry alarms.

    Science.gov (United States)

    Bonzheim, Kimberly A; Gebara, Rani I; O'Hare, Bridget M; Ellis, R Darin; Brand, Monique A; Balar, Salil D; Stockman, Rita; Sciberras, Annette M; Haines, David E

    2011-05-01

    A centralized electrocardiogram telemetry monitoring system (TMS) facilitates early identification of critical arrhythmias and acute medical decompensation. Timely intervention can only be performed if abnormalities are communicated rapidly to the direct caregiver. The study objectives were to measure effectiveness of bi-directional voice communication badges versus one-way alphanumeric pagers for telemetry alarm response and communication loop closure. A sequential observational pilot study of nursing response to TMS alarms compared communication technologies on four nursing units in a 1,061 bed tertiary care hospital with 264 TMS channels of telemetry over a 2-year period. Subsequently, the communication technologies were compared in a randomized fashion on a 68-bed progressive cardiac care unit. Caregivers were blinded to the protocol. All alarm responses were recorded during two periods using either pagers or voice communication devices. Alarm response time and closure of the communication loop were analyzed in a blinded fashion. The direct communication functionality of the badge significantly shortened the time to first contact, time to completion, and rate of closure of the communication loop in both the pilot and study phases. Median time to first contact with the communication badge was 0.5  min, compared to 1.6  min with pager communication (p Communication loop closure was achieved in 100% of clinical alarms using the badge versus 19% with the pager (p Communication badge technology reduced alarm time to first contact and completion as well as facilitated communication loop closures. Immediate two-way communication significantly impacted practice, alarm management, and resulted in faster bedside care.

  9. The Textile Elements in Ottoman Miniatures

    Directory of Open Access Journals (Sweden)

    Kevser Gürcan Y A R D I M C I

    2015-07-01

    Full Text Available With the value given to the art and the artist, high quality works of art in many fields were produced in the Ottoman Era. The art of weaving also lived its brightest period in terms of color, design, and weaving techniques in the Ottoman Empire in XVI. Ce ntury. The weaving products shaped the lifestyles of the people in those times and received great interest in the Palace as well. Silk woven fabrics had become such a great power in those times that it became the greatest symbol showing the power of the Ot toman Empire to the foreigners, and the determiner of the social standing within the society. The Ottoman Sultans used their clothing, which they made to become flamboyant with embroideries, to distinguish themselves from the public, and make them accept t heir power. Among the presents that were presented to the Sultans, clothes, kaftans, and similar fabrics as well as other precious presents, were frequent. The miniature manuscripts that were produced in the Palace are in the quality of unique documents t hat transfer yesterday’s knowledge to the modern age. It is easy to decode the dimensions of the clothing habits, decoration elements and hierarchy concepts of the Ottoman Era, as well as the weaving activities by using the miniature manuscripts. On the ot her hand, these elements constitute a rich alphabet in transferring the emotional structure of the society in those times, the traditions and habits to our world today. The greatest share in this effort belongs to the artists who depicted the miniatures by staying loyal to the texts in the manuscripts as well as to their active participation in the events of those times and their narrating the events as the very first observers. In addition, the muralists depicting the manuscripts and their undertaking the job of drawing the designs on the original fabric helped them to reflect the richness in the design of those times to the miniatures. In this study, the weavings and the accessories

  10. Miniaturized nuclear battery

    International Nuclear Information System (INIS)

    Adler, K.; Ducommun, G.

    1976-01-01

    The invention relates to a miniaturized nuclear battery, consisting of several in series connected cells, wherein each cell contains a support which acts as positive pole and which supports on one side a β-emitter, above said emitter is a radiation resisting insulation layer which is covered by an absorption layer, above which is a collector layer, and wherein the in series connected calls are disposed in an airtight case

  11. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    Science.gov (United States)

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-09-13

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles.

  12. Miniature Blimps for Surveillance and Collection of Samples

    Science.gov (United States)

    Jones, Jack

    2004-01-01

    Miniature blimps are under development as robots for use in exploring the thick, cold, nitrogen atmosphere of Saturn's moon, Titan. Similar blimps can also be used for surveillance and collection of biochemical samples in buildings, caves, subways, and other, similar structures on Earth. The widely perceived need for means to thwart attacks on buildings and to mitigate the effects of such attacks has prompted consideration of the use of robots. Relative to rover-type (wheeled) robots that have been considered for such uses, miniature blimps offer the advantage of ability to move through the air in any direction and, hence, to perform tasks that are difficult or impossible for wheeled robots, including climbing stairs and looking through windows. In addition, miniature blimps are expected to have greater range and to cost less, relative to wheeled robots.

  13. Miniature scientific-grade induction magnetometer for cubesats

    Science.gov (United States)

    Pronenko, Vira

    2017-04-01

    One of the main areas of space research is the study and forecasting of space weather. The society is more and more depending nowadays on satellite technology and communications, so it is vital to understand the physical process in the solar-terrestrial system which may disturb them. Besides the solar radiation and Space Weather effects, the Earth's ionosphere is also modified by the ever increasing industrial activity. There have been also multiple reports relating VLF and ELF wave activity to atmospheric storms and geological processes, such as earthquakes and volcanic activity. For advancing in these fields, the AC magnetic field permanent monitoring is crucial. Using the cubesat technology would allow increasing the number of measuring points dramatically. It is necessary to mention that the cubesats use for scientific research requires the miniaturization of scientific sensors what is a serious problem because the reduction of their dimensions leads, as a rule, to the parameters degradation, especially of sensitivity threshold. Today, there is no basic model of a sensitive miniature induction magnetometer. Even the smallest one of the known - for the Bepi-Colombo mission to Mercury - is too big for cubesats. The goal of the present report is to introduce the new design of miniature three-component sensor for measurement of alternative vector magnetic fields - induction magnetometer (IM). The study directions were concentrated on the ways and possibilities to create the miniature magnetometer with best combination of parameters. For this a set of scientific and technological problems, mostly aimed at the sensor construction improvement, was solved. The most important parameter characterizing magnetometer quality is its own magnetic noise level (NL). The analysis of the NL influencing factors is made and the ways to decrease it are discussed in the report. Finally, the LEMI-151 IM was developed for the SEAM cubesat mission with optimal performances within the

  14. Miniature Ground Mapping LADAR, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — System & Processes Engineering Corporation (SPEC) proposes a miniature solid state surface imaging LADAR, for imaging the landing areas providing precision...

  15. Autonomous stair-climbing with miniature jumping robots.

    Science.gov (United States)

    Stoeter, Sascha A; Papanikolopoulos, Nikolaos

    2005-04-01

    The problem of vision-guided control of miniature mobile robots is investigated. Untethered mobile robots with small physical dimensions of around 10 cm or less do not permit powerful onboard computers because of size and power constraints. These challenges have, in the past, reduced the functionality of such devices to that of a complex remote control vehicle with fancy sensors. With the help of a computationally more powerful entity such as a larger companion robot, the control loop can be closed. Using the miniature robot's video transmission or that of an observer to localize it in the world, control commands can be computed and relayed to the inept robot. The result is a system that exhibits autonomous capabilities. The framework presented here solves the problem of climbing stairs with the miniature Scout robot. The robot's unique locomotion mode, the jump, is employed to hop one step at a time. Methods for externally tracking the Scout are developed. A large number of real-world experiments are conducted and the results discussed.

  16. Central Hypothyroidism in Miniature Schnauzers

    NARCIS (Netherlands)

    Voorbij, Annemarie M W Y; Leegwater, Peter A J; Buijtels, Jenny J C W M; Daminet, Sylvie; Kooistra, Hans S

    2016-01-01

    BACKGROUND: Primary hypothyroidism is a common endocrinopathy in dogs. In contrast, central hypothyroidism is rare in this species. OBJECTIVES: The objective of this article is to describe the occurrence and clinical presentation of central hypothyroidism in Miniature Schnauzers. Additionally, the

  17. Attitude Model of a Reaction Wheel/Fixed Thruster Based Satellite Using Telemetry Data

    National Research Council Canada - National Science Library

    Smith, Jason E

    2005-01-01

    .... While there are a multitude of ways to determine a satellite's orientation, very little research has been done on determining if the attitude of a satellite can be determined directly from telemetry...

  18. Small is beautiful: features of the smallest insects and limits to miniaturization.

    Science.gov (United States)

    Polilov, Alexey A

    2015-01-07

    Miniaturization leads to considerable reorganization of structures in insects, affecting almost all organs and tissues. In the smallest insects, comparable in size to unicellular organisms, modifications arise not only at the level of organs, but also at the cellular level. Miniaturization is accompanied by allometric changes in many organ systems. The consequences of miniaturization displayed by different insect taxa include both common and unique changes. Because the smallest insects are among the smallest metazoans and have the most complex organization among organisms of the same size, their peculiar structural features and the factors that limit their miniaturization are of considerable theoretical interest to general biology.

  19. Structure Design and Performance Analysis of High-Speed Miniature Ball Bearing

    Science.gov (United States)

    Li, Songsheng; Zhang, Guoye; Chen, Bin; Shen, Yuan

    2017-07-01

    The working performances of miniature ball bearings are obviously affected by its’ geometric structure parameters. In this paper, quasi-static analysis theory is applied in the design of miniature ball bearings. Firstly, it is studied the influence of geometry structure, preload and rotating speed on the dynamic performance of bearing. Secondly, bearing dynamic characteristics are analyzed which include the bearing stiffness and Spin to roll Ratio. Lastly, the contact stress and bearing life are calculated. The results indicate that structure parameters play an importance role in bearing’s dynamic performances. Miniature ball bearings which have lager ball number, bigger ball diameter and smaller inner race groove radius can get better performances while velocity and preload have great impact on the bearing life. So that parameters of miniature bearing should be chosen cautiously.

  20. Using Miniature Landforms in Teaching Geomorphology.

    Science.gov (United States)

    Petersen, James F.

    1986-01-01

    This paper explores the uses of true landform miniatures and small-scale analogues and suggests ways to teach geomorphological concepts using small-scale relief features as illustrative examples. (JDH)

  1. Miniaturization of Multiple-Layer Folded Patch Antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Breinbjerg, Olav

    2009-01-01

    A new folded patch antenna with multiple layers was developed in this paper, by folding the patch in a proper way, and a highly miniaturized antenna can be realized. The multiple layer patch with 4-layer and 6-layer are designed and evaluated at 2.4 GHz, 915 MHz, and 415 MHz respectively. Then a 4...... layer patch is fabricated and measured to validate the design method. The theoretical analysis, design and simulations, fabrications, as well as the measurements are presented in this paper. All the results show that the folded patch antenna is a good candidate in making a highly miniaturized compact...

  2. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  3. Preface Miniaturization and Mass Spectrometry

    NARCIS (Netherlands)

    Unknown, [Unknown; le Gac, Severine; le Gac, S.; van den Berg, Albert; van den Berg, A.

    2009-01-01

    Miniaturization and Mass Spectrometry illustrates this trend and focuses on one particular analysis technique, mass spectrometry whose popularity has "dramatically" increased in the last two decades with the explosion of the field of biological analysis and the development of two "soft" ionization

  4. Satellite Telemetry and Command using Big LEO Mobile Telecommunications Systems

    Science.gov (United States)

    Huegel, Fred

    1998-01-01

    Various issues associated with satellite telemetry and command using Big LEO mobile telecommunications systems are presented in viewgraph form. Specific topics include: 1) Commercial Satellite system overviews: Globalstar, ICO, and Iridium; 2) System capabilities and cost reduction; 3) Satellite constellations and contact limitations; 4) Capabilities of Globalstar, ICO and Iridium with emphasis on Globalstar; and 5) Flight transceiver issues and security.

  5. Miniaturized inertial impactor for personal airborne particulate monitoring: Prototyping

    Science.gov (United States)

    Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele; Cortelezzi, Luca

    2017-11-01

    Computational fluid dynamic (CFD) simulations allowed us to conceive and design a miniaturized inertial impactor able to collect fine airborne particulate matter (PM10, PM2.5 and PM1). We created, by 3D printing, a prototype of the impactor. We first performed a set of experiments by applying a suction pump to the outlets and sampling the airborne particulate of our laboratory. The analysis of the slide showed a collection of a large number of particles, spanning a wide range of sizes, organized in a narrow band located below the exit of the nozzle. In order to show that our miniaturized inertial impactor can be truly used as a personal air-quality monitor, we performed a second set of experiments where the suction needed to produce the airflow through the impactor is generated by a human being inhaling through the outlets of the prototype. To guarantee a number of particles sufficient to perform a quantitative characterization, we collected particles performing ten consecutive deep inhalations. Finally, the potentiality for realistic applications of our miniaturized inertial impactor used in combination with a miniaturized single-particle detector will be discussed. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  6. Real-Time CMA Equalization of SOQPSK for Aeronautical Telemetry

    Science.gov (United States)

    2014-06-01

    1 2 4 6 Channel Length 9 20 19 4 No. of Non-zero taps 3 8 9 4 EXPERIMENTAL SETUP Implementation of the CMA for PAQ For this...through the U.S. Army Program Exectuve Offcie for Simulation, Training and Instrumentation (PEO STRI) under contract W900KK_13-C-0026 ( PAQ ...telemetry ( PAQ ),” Brigham Young University, Technical Report, 2014, submitted to the Spectrum Efficient Technologies (SET) Office of the Science

  7. A new miniature microchannel plate X-ray detector for synchrotron radiation

    International Nuclear Information System (INIS)

    Rosemeier, R.G.; Green, R.E. Jr.

    1982-01-01

    A state-of-the-art microchannel plate detector has been developed which allows real time X-ray imaging of X-ray diffraction as well as radiographic phenomenon. Advantages of the device include a 50 mm X-ray input, length less than 4'', and a weight of less than 1 lb. Since the use of synchrotron radiation is greatly facilitated by the capability of remote viewing of X-ray diffraction or radiographic images in real time, a prototype electro-optical system has been designed which couples the X-ray microchannel plate detector with a solid state television camera. Advantages of the miniature, lightweight, X-ray synchrotron camera include a large 50 mm X-ray input window, an output signal that is available in both analog format for display on a television monitor and in digital format for computer processing, and a completely modular design which allows all the components to be exchanged for other components optimally suited for the desired applications. (orig.)

  8. The design of visualization telemetry system based on camera module of the commercial smartphone

    Science.gov (United States)

    Wang, Chao; Ye, Zhao; Wu, Bin; Yin, Huan; Cao, Qipeng; Zhu, Jun

    2017-09-01

    Satellite telemetry is the vital indicators to estimate the performance of the satellite. The telemetry data, the threshold range and the variation tendency collected during the whole operational life of the satellite, can guide and evaluate the subsequent design of the satellite in the future. The rotational parts on the satellite (e.g. solar arrays, antennas and oscillating mirrors) affect collecting the solar energy and the other functions of the satellite. Visualization telemetries (pictures, video) are captured to interpret the status of the satellite qualitatively in real time as an important supplement for troubleshooting. The mature technology of commercial off-the-shelf (COTS) products have obvious advantages in terms of the design of construction, electronics, interfaces and image processing. Also considering the weight, power consumption, and cost, it can be directly used in our application or can be adopted for secondary development. In this paper, characteristic simulations of solar arrays radiation in orbit are presented, and a suitable camera module of certain commercial smartphone is adopted after the precise calculation and the product selection process. Considering the advantages of the COTS devices, which can solve both the fundamental and complicated satellite problems, this technique proposed is innovative to the project implementation in the future.

  9. Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors

    Directory of Open Access Journals (Sweden)

    Ching-Hsing Luo

    2011-09-01

    Full Text Available A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC, a microcontroller unit (MCU, a graphical user interface (GUI, and a radio frequency (RF transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA. The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment, a small size of 5.6 cm × 8.7 cm, high portability, and high integration.

  10. Effect of Wearing a Telemetry Jacket on Behavioral and Physiologic Parameters of Dogs in the Open-Field Test.

    Science.gov (United States)

    Fish, Richard E; Foster, Melanie L; Gruen, Margaret E; Sherman, Barbara L; Dorman, Davidc C

    2017-07-01

    Safety pharmacology studies in dogs often integrate behavioral assessments made using video recording with physiologic measurements collected by telemetry. However, whether merely wearing the telemetry vest affects canine behavior and other parameters has not been evaluated. This pilot study assessed the effect of a telemetry vest on behavioral and physiologic responses to an environmental stressor, the sounds of a thunderstorm, in Labrador retrievers. Dogs were assigned to one of 2 experimental groups (Vest and No-Vest, n = 8 dogs per group) by using a matched pairs design, with a previously determined, sound-associated anxiety score as the blocking variable. Dogs were individually retested with the same standardized sound stimulus (thunderstorm) in an open-field arena, and their behavioral responses were video recorded. Video analysis of locomotor activity and anxiety-related behavior and manual determination of heart rate and body temperature were performed; results were compared between groups. Vest wearing did not affect total locomotor activity or rectal body temperature but significantly decreased heart rate by 8% and overall mean anxiety score by 34% during open-field test sessions. Our results suggest that the use of telemetry vests in dogs influences the measurement of physiologic parameters and behaviors that are assessed in safety pharmacology studies.

  11. Miniaturized hand held microwave interference scanning system for NDE of dielectric armor and armor systems

    International Nuclear Information System (INIS)

    Schmidt, Karl F.; Little, Jack R.; Ellingson, William A.; Meitzler, Thomas J.; Green, William

    2011-01-01

    Inspection of ceramic-based armor has advanced through development of a microwave-based, portable, non-contact NDE system. Recently, this system was miniaturized and made wireless for maximum utility in field applications. The electronic components and functionality of the laboratory system are retained, with alternative means of position input for creation of scan images. Validation of the detection capability was recently demonstrated using specially fabricated surrogates and ballistic impact-damaged specimens. The microwave data results have been compared to data from laboratory-based microwave interferometry systems and digital x-ray imaging. The microwave interference scanning has been shown to reliably detect cracks, laminar features and material property variations. The authors present details of the system operation, descriptions of the test samples used and recent results obtained.

  12. 46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable provisions in this part for the boiler type involved and the...

  13. Prototype Sistem Multi-Telemetri Wireless untuk Mengukur Suhu Udara Berbasis Mikrokontroler ESP8266 pada Greenhouse

    Directory of Open Access Journals (Sweden)

    Hanum Shirotu Nida

    2017-07-01

    Full Text Available Telemetri wireless adalah proses pengukuran parameter suatu obyek yang hasil pengukurannya dikirimkan ke tempat lain melalui proses pengiriman data tanpa menggunakan kabel (wireless, sedangkan multi telemetri adalah gabungan dari beberapa telemeteri itu sendiri. Penelitian ini merancang prototype sistem multi-telemetri wireless untuk mengukur suhu udara dan kelembaban udara pada greenhouse dengan menggunakan sensor DHT11 dan data hasil dari pembacaan sensor dikirim dengan menggunakan modul WiFi ESP8266 ke server dengan menggunakan protokol HTTP. Dalam penelitian ini diuji nilai sensor DHT11, heap memory ESP8266, jarak atau jangkauan ESP8266, uji coba data missing handling dan kestabilan jaringan. Berdasarkan hasil pengujian diketahui bahwa sensor DHT11 memiliki rata-rata kesalahan ukur suhu 0.92 oC dan kelembaban 3.1%. Modul WiFi ESP8266 mampu menyimpan dan mengirim buffer hingga 100 data dan dapat melakukan pengiriman dalam jangkauan 50 meter. Data missing handling memanfaatkan buffer untuk menyimpan data selama server sedang tidak dapat diakses oleh sensor node agar data tidak hillang. Kestabilan pengiriman data atau koneksi sensor node dengan server dipengaruhi oleh jumlah access point yang sedang berkomunikasi disekitar access point server dengan menggunakan channel yang sama.

  14. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  15. Disturbances in VHF/UHF telemetry links as a possible effect of the 2003 Hokkaido Tokachi-oki earthquake

    Directory of Open Access Journals (Sweden)

    H. Nagamoto

    2008-08-01

    Full Text Available The data on radio telemetry links (for water information at VHF/UHF in Hokkaido are used to investigate the rate of disturbances on radio links (or connection failure and its association with a huge earthquake, Tokachi-oki earthquake on 26 September 2003. Especially, the telemetry links at the Tokachi region closest to the earthquake epicenter, showed a significant increase in disturbances on radio links two weeks to a few days before the earthquake on the basis of analysis during a long interval from 1 June 2002 to 3 November 2007 (over 5 years. We suggest that these severe disturbances in VHF/UHF telemetry links are attributed to the generation of seismogenic VHF/UHF radio noises (emissions. Based on this idea, we have estimated that the intensity of these seismogenic emissions is on the order of 10–19 dB μV/m. Finally, the present result was compared with other physical parameters already obtained for this earthquake.

  16. Glomerular Lesions in Proteinuric Miniature Schnauzer Dogs.

    Science.gov (United States)

    Furrow, E; Lees, G E; Brown, C A; Cianciolo, R E

    2017-05-01

    Miniature Schnauzer dogs are predisposed to idiopathic hypertriglyerceridemia, which increases risk for diseases such as pancreatitis and gallbladder mucocele. Recently, elevated triglyceride concentrations have been associated with proteinuria in this breed, although it is difficult to determine which abnormality is primary. Retrospective review of renal tissue from 27 proteinuric Miniature Schnauzers revealed that 20 dogs had ultrastructural evidence of osmophilic globules consistent with lipid in glomerular tufts. Seven of these dogs had lipid thromboemboli in glomerular capillary loops that distorted their shape and compressed circulating erythrocytes. Triglyceride concentrations were reported in 6 of these 7 dogs, and all were hypertriglyceridemic. In addition, glomerular lipidosis (defined as accumulation of foam cells within peripheral capillary loops) was identified in a single dog. The remaining 12 dogs had smaller amounts of lipid that could only be identified ultrastructurally. Neither signalment data nor clinicopathologic parameters (serum albumin, serum creatinine, urine protein-to-creatinine ratio, and blood pressure) differed among the various types of lipid lesions. During the time course of this study, all dogs diagnosed with glomerular lipid thromboemboli were Miniature Schnauzers, underscoring the importance of recognizing these clear spaces within capillary loops as lipid.

  17. Design of a wireless radiation telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Chiang, H H [Chung Yuan Christian Coll. of Science and Engineering, Chung-Li, Taiwan; Chang, J K

    1976-12-01

    The wireless radiation telemetry system can be operated in all seasons. It is designed for the measurement of radiation intensities up to millicurie order at a distance of 1 Km or less. Its measuring error is +-0.01 percent deviation from the count rate of the typical direct-detecting instrument with the same radiation source. This error indicates that the accuracy is high enough for practical uses. This system is cheaper and more flexible, comparing with the corresponding cable facility. The line-of-sight transmission distance can be longer if the transmitting power is appropriately increased. All pulse type radiation detectors can be used as the input section of this system.

  18. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  19. Modeling of acoustic wave propagation and scattering for telemetry of complex structures; Modelisation de la propagation et de l'interaction d'une onde acoustique pour la telemetrie de structures complexes

    Energy Technology Data Exchange (ETDEWEB)

    LU, B.

    2011-11-07

    This study takes place in the framework of tools development for the telemetry simulation. Telemetry is a possible technology applied to monitoring the sodium-cooled fast reactors (SFR) and consists in positioning in the reactor core a transducer to generate an ultrasonic beam. This beam propagates through an inhomogeneous random medium since temperature fluctuations occur in the liquid sodium and consequently the sound velocity fluctuates as well, which modifies the bream propagation. Then the beam interacts with a reactor structure immersed in sodium. By measuring the time of flight of the backscattered echo received by the same transducer, one can determine the precise location of the structure. The telemetry simulation therefore requires modeling of both the acoustic wave propagation in an inhomogeneous random medium and the interaction of this wave with structures of various shapes; this is the objective of this work. A stochastic model based on a Monte Carlo algorithm is developed in order to take into account the random fluctuations of the acoustic field. The acoustic field through an inhomogeneous random medium is finally modeled from the field calculated in a mean homogeneous medium by modifying the travel times of rays in the homogeneous medium, using a correction provided by the stochastic model. This stochastic propagation model has been validated by comparison with a deterministic model and is much simpler to integrate in the CIVA software platform for non destructive evaluation simulation and less time consuming than the deterministic model. In order to model the interaction between the acoustic wave and the immersed structures, classical diffraction models have been evaluated for rigid structures, including the geometrical theory of diffraction (GTD) and the Kirchhoff approximation (KA). These two approaches appear to be complementary. Combining them so as to retain only their advantages, we have developed a hybrid model (the so-called refined KA

  20. A Model for Real-Time Data Reputation Via Cyber Telemetry

    Science.gov (United States)

    2016-06-01

    methodology which focuses on iterative cycles, known as sprints, to produce the capabilities of the system. Traditional waterfall models do not allow for...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited A MODEL FOR REAL...Master’s Thesis 4. TITLE AND SUBTITLE A MODEL FOR REAL-TIME DATA REPUTATION VIA CYBER TELEMETRY 5. FUNDING NUMBERS 6. AUTHOR(S) Beau M

  1. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    Science.gov (United States)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  2. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    International Nuclear Information System (INIS)

    Hocking, Erica G; Wereley, Norman M

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30–80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible. (paper)

  3. Miniature bread baking as a timesaving research approach and mathematical modeling of browning kinetics

    NARCIS (Netherlands)

    Zhang, Lu; Putranto, Aditya; Zhou, Weibiao; Boom, Remko M.; Schutyser, Maarten A.I.; Chen, Xiao Dong

    2016-01-01

    Miniature bread baking is presented as an economical and timesaving laboratory approach to study the baking process in the present work. Results indicate that the miniature bread baking is essentially analogical to the baking process of regular-sized bread: quality-related properties of miniature

  4. Alaska Steller Sea Lion Habitat Model Satellite Telemetry and Environmental Data, 2000-2012

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The at-sea habitat use of Steller sea lions was modeled from location and dive behavior data obtained from the deployment of satellite-linked telemetry tags on sea...

  5. DropBot: An open-source digital microfluidic control system with precise control of electrostatic driving force and instantaneous drop velocity measurement

    International Nuclear Information System (INIS)

    Fobel, Ryan; Fobel, Christian; Wheeler, Aaron R.

    2013-01-01

    We introduce DropBot: an open-source instrument for digital microfluidics (http://microfluidics.utoronto.ca/dropbot). DropBot features two key functionalities for digital microfluidics: (1) real-time monitoring of instantaneous drop velocity (which we propose is a proxy for resistive forces), and (2) application of constant electrostatic driving forces through compensation for amplifier-loading and device capacitance. We anticipate that this system will enhance insight into failure modes and lead to new strategies for improved device reliability, and will be useful for the growing number of users who are adopting digital microfluidics for automated, miniaturized laboratory operation.

  6. Miniature ingestible telemeter devices to measure deep-body temperature

    Science.gov (United States)

    Pope, J. M.; Fryer, T. B. (Inventor)

    1976-01-01

    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health.

  7. Conversion from Engineering Units to Telemetry Counts on Dryden Flight Simulators

    Science.gov (United States)

    Fantini, Jay A.

    1998-01-01

    Dryden real-time flight simulators encompass the simulation of pulse code modulation (PCM) telemetry signals. This paper presents a new method whereby the calibration polynomial (from first to sixth order), representing the conversion from counts to engineering units (EU), is numerically inverted in real time. The result is less than one-count error for valid EU inputs. The Newton-Raphson method is used to numerically invert the polynomial. A reverse linear interpolation between the EU limits is used to obtain an initial value for the desired telemetry count. The method presented here is not new. What is new is how classical numerical techniques are optimized to take advantage of modem computer power to perform the desired calculations in real time. This technique makes the method simple to understand and implement. There are no interpolation tables to store in memory as in traditional methods. The NASA F-15 simulation converts and transmits over 1000 parameters at 80 times/sec. This paper presents algorithm development, FORTRAN code, and performance results.

  8. Monitoring and Analysis of In-Pile Phenomena in Advanced Test Reactor using Acoustic Telemetry

    International Nuclear Information System (INIS)

    Agarwal, Vivek; Smith, James A.; Jewell, James Keith

    2015-01-01

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. A number of research programs are developing acoustic-based sensing approach to take advantage of the acoustic transmission properties of reactor cores. Idaho National Laboratory has installed vibroacoustic receivers on and around the Advanced Test Reactor (ATR) containment vessel to take advantage of acoustically telemetered sensors such as thermoacoustic (TAC) transducers. The installation represents the first step in developing an acoustic telemetry infrastructure. This paper presents the theory of TAC, application of installed vibroacoustic receivers in monitoring the in-pile phenomena inside the ATR, and preliminary data processing results.

  9. Monitoring and Analysis of In-Pile Phenomena in Advanced Test Reactor using Acoustic Telemetry

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Vivek [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Human Factors, Controls, and Statistics; Smith, James A. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Fuel Performance and Design; Jewell, James Keith [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Fuel Performance and Design

    2015-02-01

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. A number of research programs are developing acoustic-based sensing approach to take advantage of the acoustic transmission properties of reactor cores. Idaho National Laboratory has installed vibroacoustic receivers on and around the Advanced Test Reactor (ATR) containment vessel to take advantage of acoustically telemetered sensors such as thermoacoustic (TAC) transducers. The installation represents the first step in developing an acoustic telemetry infrastructure. This paper presents the theory of TAC, application of installed vibroacoustic receivers in monitoring the in-pile phenomena inside the ATR, and preliminary data processing results.

  10. Miniaturization design and implementation of magnetic field coupled RFID antenna

    Science.gov (United States)

    Hu, Tiling

    2013-03-01

    The development of internet of things has brought new opportunities and challenges to the application of RFID tags. Moreover, the Miniaturization application trend of tags at present has become the mainstream of development. In this paper, the double-layer design is to reduce the size of HF antenna, and the magnetic null point of magnetic reconnection region between the RLC resonant circuit and the reader provides sufficient energy to the miniaturization of antenna. The calculated and experimental results show that the miniaturization of HF antennas can meet the reading and writing requirement of the international standard ISO/IEC14443 standard. The results of this paper may make a positive contribution to the applications of RFID technology.

  11. Evaluation of the cationic trypsinogen gene for potential mutations in miniature schnauzers with pancreatitis.

    Science.gov (United States)

    Bishop, Micah A; Steiner, Jörg M; Moore, Lisa E; Williams, David A

    2004-10-01

    The purpose of this study was to evaluate the cationic trypsinogen gene in miniature schnauzers for possible mutations. Genetic mutations have been linked with hereditary pancreatitis in humans. Four miniature schnauzers were selected on the basis of a clinical history of pancreatitis. One healthy miniature schnauzer and 1 healthy mixed breed canine were enrolled as controls. DNA was extracted from these canines using a commercial kit. Primers were designed to amplify the entire canine cationic trypsinogen cDNA sequence. A polymerase chain reaction (PCR) was performed and products were purified and sequenced. All sequences were then compared. The healthy control canine, a healthy miniature schnauzer, and the 4 miniature schnauzers with pancreatitis showed identical sequences of the cationic trypsinogen gene to the published sequence. We conclude that, in contrast to humans with hereditary pancreatitis, mutations of the cationic trypsinogen gene do not play a major role in the genesis of pancreatitis in the miniature schnauzer.

  12. In-Flight Fault Diagnosis for Autonomous Aircraft Via Low-Rate Telemetry Channel

    DEFF Research Database (Denmark)

    Blanke, Mogens; Hansen, Søren

    2012-01-01

    An in-flight diagnosis system that is able to detect faults on an unmanned aircraft using real-time telemetry data could provide operator assistance to warn about imminent risks due to faults. However, limited bandwidth of the air-ground radio-link makes diagnosis difficult. Loss of information a...

  13. Mobile technology and the digitization of healthcare.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Narula, Jagat; Sengupta, Partho P

    2016-05-07

    The convergence of science and technology in our dynamic digital era has resulted in the development of innovative digital health devices that allow easy and accurate characterization in health and disease. Technological advancements and the miniaturization of diagnostic instruments to modern smartphone-connected and mobile health (mHealth) devices such as the iECG, handheld ultrasound, and lab-on-a-chip technologies have led to increasing enthusiasm for patient care with promises to decrease healthcare costs and to improve outcomes. This 'hype' for mHealth has recently intersected with the 'real world' and is providing important insights into how patients and practitioners are utilizing digital health technologies. It is also raising important questions regarding the evidence supporting widespread device use. In this state-of-the-art review, we assess the current literature of mHealth and aim to provide a framework for the advances in mHealth by understanding the various device, patient, and clinical factors as they relate to digital health from device designs and patient engagement, to clinical workflow and device regulation. We also outline new strategies for generation and analysis of mHealth data at the individual and population-based levels. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  14. Characterization of a planar microcoil for implantable microsystems

    NARCIS (Netherlands)

    Neagu, Cristina; Rusu, C.R.; Jansen, Henricus V.; Smith, A.; Gardeniers, Johannes G.E.; Elwenspoek, Michael Curt

    This paper discusses the modelling, design and characterization of planar microcoils to be used in telemetry systems that supply energy to miniaturized implants. Parasitic electrical effects that may become important at a.c. frequencies of several megahertz are evaluated. The fabrication process and

  15. Laser direct marking applied to rasterizing miniature Data Matrix Code on aluminum alloy

    Science.gov (United States)

    Li, Xia-Shuang; He, Wei-Ping; Lei, Lei; Wang, Jian; Guo, Gai-Fang; Zhang, Teng-Yun; Yue, Ting

    2016-03-01

    Precise miniaturization of 2D Data Matrix (DM) Codes on Aluminum alloy formed by raster mode laser direct part marking is demonstrated. The characteristic edge over-burn effects, which render vector mode laser direct part marking inadequate for producing precise and readable miniature codes, are minimized with raster mode laser marking. To obtain the control mechanism for the contrast and print growth of miniature DM code by raster laser marking process, the temperature field model of long pulse laser interaction with material is established. From the experimental results, laser average power and Q frequency have an important effect on the contrast and print growth of miniature DM code, and the threshold of laser average power and Q frequency for an identifiable miniature DM code are respectively 3.6 W and 110 kHz, which matches the model well within normal operating conditions. In addition, the empirical model of correlation occurring between laser marking parameters and module size is also obtained, and the optimal processing parameter values for an identifiable miniature DM code of different but certain data size are given. It is also found that an increase of the repeat scanning number effectively improves the surface finish of bore, the appearance consistency of modules, which has benefit to reading. The reading quality of miniature DM code is greatly improved using ultrasonic cleaning in water by avoiding the interference of color speckles surrounding modules.

  16. A portable telemetry system for brain stimulation and neuronal activity recording in freely behaving small animals.

    Science.gov (United States)

    Ye, Xuesong; Wang, Peng; Liu, Jun; Zhang, Shaomin; Jiang, Jun; Wang, Qingbo; Chen, Weidong; Zheng, Xiaoxiang

    2008-09-30

    A portable multi-channel telemetry system which can be used for brain stimulation and neuronal activity recording in freely behaving small animals is described here. This system consists of three major components of headstage, backpack and portable Personal Digital Assistant (PDA). The headstage contains high precision instrument amplifiers with high input impedance. The backpack is comprised of two parts: (1) a main board (size: 36 mm x 22 mm x 3.5 mm and weight: 40 g with batteries, 20 g without), with current/voltage stimulator and special circuit suitable for neuronal activity recording and (2) and a bluetooth transceiver, with a high data transmission rate up to 70 kb/s, suitable for downloading stimulation commands and uploading acquired data. We recorded neuronal activities of the primary motor area of a freely behaving rat with 12-bit resolution at 12 k samples/s. The recorded data and analysis results showed that the system was successful by comparing with the commercial equipment Cerebus 128-Channel Data Acquisition System (Cyberkinetics Inc.). Using the PDA, we can control stimulation and recording. It provides a flexible method to do some research work in the circumstances where other approaches would be difficult or impossible.

  17. Telemetry Standards, IRIG Standard 106-17, Chapter 22, Network Based Protocol Suite

    Science.gov (United States)

    2017-07-01

    requirements. 22.2 Network Access Layer 22.2.1 Physical Layer Connectors and cable media should meet the electrical or optical properties required by the...Telemetry Standards, IRIG Standard 106-17 Chapter 22, July 2017 i CHAPTER 22 Network -Based Protocol Suite Acronyms...iii Chapter 22. Network -Based Protocol Suite

  18. Development of a High-Temperature Smart Transducer Interface Node and Telemetry System (HSTINTS)

    Energy Technology Data Exchange (ETDEWEB)

    Buckner, M.A. et al.

    2006-11-03

    Halliburton Energy Services and Oak Ridge National Laboratory established a CRADA to conduct applied research to develop a general purpose, High-Temperature, Smart Transducer Interface Node and Telemetry System (HSTINTS) capable of temporally-coherent multiple-channel, high speed, high-resolution data transuction and acquisition while operating in a hostile thermal, chemical, and pressure environment for extended periods of time over a single coaxial cable. This ambitious, high-risk effort required development of custom dielectric isolated integrated circuits, amplified hybrid couplers for telemetry and an audio-frequency based power supply and distribution system using an engineered application of standing waves to compensate voltage drop along a 2 mile long cable. Several goals were achieved but underestimated challenges and a couple of mistakes hampered progress. When it was determined that an additional year of concerted effort would be required to complete the system demonstration, the sponsor withdrew funding and terminated the effort.

  19. Aesthetics of Islamic Miniature Art During the Periods of Safavid and ...

    African Journals Online (AJOL)

    Islamic art represents the spiritual and physical aspects in the lives of Muslims. Meaningful beauty in Islamic art expresses Islamic aesthetics. Islamic aesthetics is the connection between beauty and the sacred. The article is devoted to the Islamic art and miniature paintings of Timurid and Safavid periods in Iran. Miniature ...

  20. Airtight miniaturized chromatography: a safer method for radiopharmaceutical quality control

    International Nuclear Information System (INIS)

    Coupal, J.J.; Shih, W.J.; Ryo, U.Y.

    1988-01-01

    Miniaturized chromatography is widely used for quality control of radiopharmaceuticals. Recently, published chromatography procedures have illustrated or described chromatography chambers open to the air in use, suggesting that volatile toxic mobile phases are harmless to people in the vicinity. The authors describe the results of their search for an inexpensive closed chromatography chamber that can be used to derive safely the benefits from conventional miniaturized chromatography

  1. Low-power, miniature {sup 171}Yb ion clock using an ultra-small vacuum package

    Energy Technology Data Exchange (ETDEWEB)

    Jau, Y.-Y.; Schwindt, P. D. D. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Partner, H. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States); Center for Quantum Information and Control (CQuIC), Department of Physics and Astronomy, University of New Mexico, Albuquerque, New Mexico 87131 (United States); Prestage, J. D.; Kellogg, J. R.; Yu, N. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California 91109 (United States)

    2012-12-17

    We report a demonstration of a very small microwave atomic clock using the 12.6 GHz hyperfine transition of the trapped {sup 171}Yb ions inside a miniature, completely sealed-off 3 cm{sup 3} ion-trap vacuum package. In the ion clock system, all of the components are highly miniaturized with low power consumption except the 369 nm optical pumping laser still under development for miniaturization. The entire clock, including the control electronics, consumes <300 mW. The fractional frequency instability of the miniature Yb{sup +} clock reaches the 10{sup -14} range after a few days of integration.

  2. High Performance Miniature Bandpass Filters, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is submitted for developing low impedance, miniature bandpass RF frequency filter via MEMS technique, in applications of SMAP, Aquarius follow-on,...

  3. A high speed multi-tasking, multi-processor telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kung Chris [Univ. of Texas, El Paso, TX (United States)

    1996-12-31

    This paper describes a small size, light weight, multitasking, multiprocessor telemetry system capable of collecting 32 channels of differential signals at a sampling rate of 6.25 kHz per channel. The system is designed to collect data from remote wind turbine research sites and transfer the data via wireless communication. A description of operational theory, hardware components, and itemized cost is provided. Synchronization with other data acquisition systems and test data on data transmission rates is also given. 11 refs., 7 figs., 4 tabs.

  4. A Spectral Reconstruction Algorithm of Miniature Spectrometer Based on Sparse Optimization and Dictionary Learning.

    Science.gov (United States)

    Zhang, Shang; Dong, Yuhan; Fu, Hongyan; Huang, Shao-Lun; Zhang, Lin

    2018-02-22

    The miniaturization of spectrometer can broaden the application area of spectrometry, which has huge academic and industrial value. Among various miniaturization approaches, filter-based miniaturization is a promising implementation by utilizing broadband filters with distinct transmission functions. Mathematically, filter-based spectral reconstruction can be modeled as solving a system of linear equations. In this paper, we propose an algorithm of spectral reconstruction based on sparse optimization and dictionary learning. To verify the feasibility of the reconstruction algorithm, we design and implement a simple prototype of a filter-based miniature spectrometer. The experimental results demonstrate that sparse optimization is well applicable to spectral reconstruction whether the spectra are directly sparse or not. As for the non-directly sparse spectra, their sparsity can be enhanced by dictionary learning. In conclusion, the proposed approach has a bright application prospect in fabricating a practical miniature spectrometer.

  5. Fiber Optic Telemetry System for LLL High-Voltage Test Stand

    International Nuclear Information System (INIS)

    Richter, J.P.

    1977-01-01

    This paper describes the Fiber Optic Telemetry System designed to operate in the hostile particle and electromagnetic radiation environment of the High Voltage Test Stand. It discusses system criteria, components, packaging, and performance. In all tests to date, the system exceeds its design goals with very comfortable margins. It is well advanced into the fabrication stages with all crucial components tested and only straightforward TTL (Transistor Transistor Logic) circuitry to be completed

  6. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  7. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  8. Loop migration in adult marsh harriers Circus aeruginosus, as revealed by satellite telemetry

    DEFF Research Database (Denmark)

    H. G. Klaassen, Raymond; Strandberg, Roine; Hake, Mikael

    2010-01-01

    level, for example by analysing ring recoveries. Here we study loop migration of individual marsh harriersCircus aeruginosus tracked by satellite telemetry. We show that despite a generally narrow migration corridor the harriers travelled in a distinct clockwise loop through Africa and southern Europe...

  9. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  10. Telemetry and Communication IP Video Player

    Science.gov (United States)

    OFarrell, Zachary L.

    2011-01-01

    Aegis Video Player is the name of the video over IP system for the Telemetry and Communications group of the Launch Services Program. Aegis' purpose is to display video streamed over a network connection to be viewed during launches. To accomplish this task, a VLC ActiveX plug-in was used in C# to provide the basic capabilities of video streaming. The program was then customized to be used during launches. The VLC plug-in can be configured programmatically to display a single stream, but for this project multiple streams needed to be accessed. To accomplish this, an easy to use, informative menu system was added to the program to enable users to quickly switch between videos. Other features were added to make the player more useful, such as watching multiple videos and watching a video in full screen.

  11. Narrative Metamorphosis Through Images: The Case of Opening Miniatures in the Estoire del

    Directory of Open Access Journals (Sweden)

    Miha Zor

    2015-12-01

    Full Text Available The article deals with pictorial metamorphosis in the opening pages of two early 14th-century manuscripts of the Estoire del saint Graal. Firstly, the episodes depicted are analysed iconographically and formally. Secondly, it explores how pictorial narrative is established in the multi-compartmentalised miniature, that is how the images are linked internally in order to convey a narrative that has its beginning and its ending. Thirdly, it is shown how the images in the opening miniature communicate with other miniatures in the manuscript and how the course of interpretation, signaled by the opening miniature, is succeeded and confirmed by the selection of episodes which are subsequently depicted, as well as by the way in which the episodes depicted are pictorially interpreted.

  12. Incorporating temporal variation in seabird telemetry data: time variant kernel density models

    Science.gov (United States)

    Gilbert, Andrew; Adams, Evan M.; Anderson, Carl; Berlin, Alicia; Bowman, Timothy D.; Connelly, Emily; Gilliland, Scott; Gray, Carrie E.; Lepage, Christine; Meattey, Dustin; Montevecchi, William; Osenkowski, Jason; Savoy, Lucas; Stenhouse, Iain; Williams, Kathryn

    2015-01-01

    A key component of the Mid-Atlantic Baseline Studies project was tracking the individual movements of focal marine bird species (Red-throated Loon [Gavia stellata], Northern Gannet [Morus bassanus], and Surf Scoter [Melanitta perspicillata]) through the use of satellite telemetry. This element of the project was a collaborative effort with the Department of Energy (DOE), Bureau of Ocean Energy Management (BOEM), the U.S. Fish and Wildlife Service (USFWS), and Sea Duck Joint Venture (SDJV), among other organizations. Satellite telemetry is an effective and informative tool for understanding individual animal movement patterns, allowing researchers to mark an individual once, and thereafter follow the movements of the animal in space and time. Aggregating telemetry data from multiple individuals can provide information about the spatial use and temporal movements of populations. Tracking data is three dimensional, with the first two dimensions, X and Y, ordered along the third dimension, time. GIS software has many capabilities to store, analyze and visualize the location information, but little or no support for visualizing the temporal data, and tools for processing temporal data are lacking. We explored several ways of analyzing the movement patterns using the spatiotemporal data provided by satellite tags. Here, we present the results of one promising method: time-variant kernel density analysis (Keating and Cherry, 2009). The goal of this chapter is to demonstrate new methods in spatial analysis to visualize and interpret tracking data for a large number of individual birds across time in the mid-Atlantic study area and beyond. In this chapter, we placed greater emphasis on analytical methods than on the behavior and ecology of the animals tracked. For more detailed examinations of the ecology and wintering habitat use of the focal species in the midAtlantic, see Chapters 20-22.

  13. Miniature and micro mass spectrometry for nanoscale sensing applications

    International Nuclear Information System (INIS)

    Taylor, S; France, N

    2009-01-01

    In recent years the use of miniature and/or microscale versions of the more popular mass spectrometers have been realised. This has led to the development of portable analytical devices for a range of 'in the field' sensing applications in aerospace, environmental monitoring, medical diagnosis and process control. In this paper the principles underpinning the development of miniature quadrupole mass spectrometers are reviewed. Two different microfabrication methods are compared with a conventional QMS used for residual gas analysis in the range 1-100 Da.

  14. EMC, RF, and Antenna Systems in Miniature Electronic Devices

    DEFF Research Database (Denmark)

    Ruaro, Andrea

    Advanced techniques for the control of electromagnetic interference (EMI) and for the optimization of the electromagnetic compatibility (EMC) performance has been developed under the constraints typical of miniature electronic devices (MED). The electromagnetic coexistence of multiple systems....... The structure allows for effective suppression of radiation from the MED, while taking into consideration the integration and miniaturization aspects. To increase the sensitivity of the system, a compact LNA suitable for on-body applications has been developed. The LNA allows for an increase in the overall...

  15. On a digital wireless impact-monitoring network for large-scale composite structures

    International Nuclear Information System (INIS)

    Yuan, Shenfang; Mei, Hanfei; Qiu, Lei; Ren, Yuanqiang

    2014-01-01

    Impact, which may occur during manufacture, service or maintenance, is one of the major concerns to be monitored throughout the lifetime of aircraft composite structures. Aiming at monitoring impacts online while minimizing the weight added to the aircraft to meet the strict limitations of aerospace engineering, this paper puts forward a new digital wireless network based on miniaturized wireless digital impact-monitoring nodes developed for large-scale composite structures. In addition to investigations on the design methods of the network architecture, time synchronization and implementation method, a conflict resolution method based on the feature parameters of digital sequences is first presented to address impact localization conflicts when several nodes are arranged close together. To verify the feasibility and stability of the wireless network, experiments are performed on a complex aircraft composite wing box and an unmanned aerial vehicle (UAV) composite wing. Experimental results show the successful design of the presented network. (paper)

  16. A Spectral Reconstruction Algorithm of Miniature Spectrometer Based on Sparse Optimization and Dictionary Learning

    Science.gov (United States)

    Zhang, Shang; Fu, Hongyan; Huang, Shao-Lun; Zhang, Lin

    2018-01-01

    The miniaturization of spectrometer can broaden the application area of spectrometry, which has huge academic and industrial value. Among various miniaturization approaches, filter-based miniaturization is a promising implementation by utilizing broadband filters with distinct transmission functions. Mathematically, filter-based spectral reconstruction can be modeled as solving a system of linear equations. In this paper, we propose an algorithm of spectral reconstruction based on sparse optimization and dictionary learning. To verify the feasibility of the reconstruction algorithm, we design and implement a simple prototype of a filter-based miniature spectrometer. The experimental results demonstrate that sparse optimization is well applicable to spectral reconstruction whether the spectra are directly sparse or not. As for the non-directly sparse spectra, their sparsity can be enhanced by dictionary learning. In conclusion, the proposed approach has a bright application prospect in fabricating a practical miniature spectrometer. PMID:29470406

  17. Flight Demonstration Results of an Inertial Measurement Unit and Global Positioning System Translator Telemetry System

    National Research Council Canada - National Science Library

    David, Bradford

    2001-01-01

    .... A GPS translator from the Johns Hopkins University Applied Physics Laboratory and a low-cost IMU designed by ARL from commercial off-the-shelf components were combined with a telemetry system, packaged...

  18. Plasma Structure and Behavior of Miniature Ring-Cusp Discharges

    Science.gov (United States)

    Mao, Hann-Shin

    Miniature ring-cusp ion thrusters provide a unique blend of high efficiencies and millinewton level thrust for future spacecraft. These thrusters are attractive as a primary propulsion for small satellites that require a high delta V, and as a secondary propulsion for larger spacecraft that require precision formation flying, disturbance rejection, or attitude control. To ensure desirable performance throughout the life of such missions, an advancement in the understanding of the plasma structure and behavior of miniature ring-cusp discharges is required. A research model was fabricated to provide a simplified experimental test bed for the analysis of the plasma discharge chamber of a miniature ion thruster. The plasma source allowed for spatially resolved measurements with a Langmuir probe along a meridian plane. Probe measurements yielded plasma density, electron temperature, and plasma potential data. The magnetic field strength was varied along with the discharge current to determine the plasma behavior under various conditions. The structure of the plasma properties were found to be independent of the discharge power under the proper scaling. It was concluded that weaker magnetic fields can improve the overall performance for ion thruster operation. To further analyze the experimental measurements, a framework was developed based on the magnetic field. A flux aligned coordinate system was developed to decouple the perpendicular and parallel plasma motion with respect to the magnetic field. This was done using the stream function and magnetic scalar potential. Magnetic formulae provided intuition on the field profiles dependence on magnet dimensions. The flux aligned coordinate system showed that the plasma was isopycnic along constant stream function values. This was used to develop an empirical relation suitable for estimating the spatial behavior and to determine the plasma volume and loss areas. The plasma geometry estimates were applied to a control volume

  19. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh

    2016-01-01

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography

  20. A miniature X-ray tube based on carbon nanotube for an intraoral dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Park, Han Beom; Lee, Ju Hyuk; Cho, Sung Oh [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    The number of human teeth that can be radiographically taken is limited. Moreover, at least two X-ray shots are required to get images of teeth from both sides of the mouth. In order to overcome the disadvantages of conventional dental radiography, a dental radiograph has been proposed in which an X-ray tube is inserted into the mouth while an X-ray detector is placed outside the mouth. The miniature X-ray tube is required small size to insert into the mouth. Recently, we have fabricated a miniature x-ray tube with the diameter of 7 mm using a carbon nanotube (CNT) field. But, commercialized miniature X-ray tube were adopted a thermionic type using tungsten filament. The X-ray tubes adopted thermionic emission has a disadvantage of increasing temperature of x-ray tube. So it need to cooling system to cool x-ray tube. On the other hands, X-ray tubes adopted CNT field emitters don't need cooling systems because electrons are emitted from CNT by applying high voltage without heating. We have developed the miniature x-ray tube that produce x-ray with uniform spatial distribution based on carbon nanotube field emitters. The fabricated miniature x-ray tube can be stably and reliably operated at 50kV without any vacuum pump. The developed miniature X-ray tube was applied for intraoral dental radiography that employs an intra-oral CNT-based miniature X-ray tube and extra-oral X-ray detectors. An X-ray image of many teeth was successfully obtained by a single X-ray shot using the intra-oral miniature X-ray tube system. Furthermore, images of both molar teeth of pig were simultaneously obtained by a single X-ray shot. These results show that the intraoral dental radiography, which employs an intraoral miniature X-ray tube and an extraoral X-ray detector, performs better than conventional dental radiography.

  1. Miniaturized Aptamer-Based Assays for Protein Detection

    Directory of Open Access Journals (Sweden)

    Alessandro Bosco

    2016-09-01

    Full Text Available The availability of devices for cancer biomarker detection at early stages of the disease is one of the most critical issues in biomedicine. Towards this goal, to increase the assay sensitivity, device miniaturization strategies empowered by the employment of high affinity protein binders constitute a valuable approach. In this work we propose two different surface-based miniaturized platforms for biomarker detection in body fluids: the first platform is an atomic force microscopy (AFM-based nanoarray, where AFM is used to generate functional nanoscale areas and to detect biorecognition through careful topographic measurements; the second platform consists of a miniaturized electrochemical cell to detect biomarkers through electrochemical impedance spectroscopy (EIS analysis. Both devices rely on robust and highly-specific protein binders as aptamers, and were tested for thrombin detection. An active layer of DNA-aptamer conjugates was immobilized via DNA directed immobilization on complementary single-stranded DNA self-assembled monolayers confined on a nano/micro area of a gold surface. Results obtained with these devices were compared with the output of surface plasmon resonance (SPR assays used as reference. We succeeded in capturing antigens in concentrations as low as a few nM. We put forward ideas to push the sensitivity further to the pM range, assuring low biosample volume (μL range assay conditions.

  2. High data rate coding for the space station telemetry links.

    Science.gov (United States)

    Lumb, D. R.; Viterbi, A. J.

    1971-01-01

    Coding systems for high data rates were examined from the standpoint of potential application in space-station telemetry links. Approaches considered included convolutional codes with sequential, Viterbi, and cascaded-Viterbi decoding. It was concluded that a high-speed (40 Mbps) sequential decoding system best satisfies the requirements for the assumed growth potential and specified constraints. Trade-off studies leading to this conclusion are viewed, and some sequential (Fano) algorithm improvements are discussed, together with real-time simulation results.

  3. Microsupercapacitors as miniaturized energy-storage components for on-chip electronics

    Science.gov (United States)

    Kyeremateng, Nana Amponsah; Brousse, Thierry; Pech, David

    2017-01-01

    The push towards miniaturized electronics calls for the development of miniaturized energy-storage components that can enable sustained, autonomous operation of electronic devices for applications such as wearable gadgets and wireless sensor networks. Microsupercapacitors have been targeted as a viable route for this purpose, because, though storing less energy than microbatteries, they can be charged and discharged much more rapidly and have an almost unlimited lifetime. In this Review, we discuss the progress and the prospects of integrated miniaturized supercapacitors. In particular, we discuss their power performances and emphasize the need of a three-dimensional design to boost their energy-storage capacity. This is obtainable, for example, through self-supported nanostructured electrodes. We also critically evaluate the performance metrics currently used in the literature to characterize microsupercapacitors and offer general guidelines to benchmark performances towards prospective applications.

  4. Miniature Active Space Radiation Dosimeter, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Space Micro will extend our Phase I R&D to develop a family of miniature, active space radiation dosimeters/particle counters, with a focus on biological/manned...

  5. Miniaturized radiation chirper

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1980-01-01

    A miniaturized radiation chirper for use with a small battery supplying on the order of 5 volts is described. A poor quality CdTe crystal which is not necessarily suitable for high resolution gamma ray spectroscopy is incorporated with appropriate electronics so that the chirper emits an audible noise at a rate that is proportional to radiation exposure level. The chirper is intended to serve as a personnel radiation warning device that utilizes new and novel electronics with a novel detector, a CdTe crystal. The resultant device is much smaller and has much longer battery life than existing chirpers

  6. A Novel High-Precision Digital Tunneling Magnetic Resistance-Type Sensor for the Nanosatellites’ Space Application

    Directory of Open Access Journals (Sweden)

    Xiangyu Li

    2018-03-01

    Full Text Available Micro-electromechanical system (MEMS magnetic sensors are widely used in the nanosatellites field. We proposed a novel high-precision miniaturized three-axis digital tunneling magnetic resistance-type (TMR sensor. The design of the three-axis digital magnetic sensor includes a low-noise sensitive element and high-performance interface circuit. The TMR sensor element can achieve a background noise of 150 pT/Hz1/2 by the vertical modulation film at a modulation frequency of 5 kHz. The interface circuit is mainly composed of an analog front-end current feedback instrumentation amplifier (CFIA with chopper structure and a fully differential 4th-order Sigma-Delta (ΣΔ analog to digital converter (ADC. The low-frequency 1/f noise of the TMR magnetic sensor are reduced by the input-stage and system-stage chopper. The dynamic element matching (DEM is applied to average out the mismatch between the input and feedback transconductor so as to improve the gain accuracy and gain drift. The digital output is achieved by a switched-capacitor ΣΔ ADC. The interface circuit is implemented by a 0.35 μm CMOS technology. The performance test of the TMR magnetic sensor system shows that: at a 5 V operating voltage, the sensor can achieve a power consumption of 120 mW, a full scale of ±1 Guass, a bias error of 0.01% full scale (FS, a nonlinearity of x-axis 0.13% FS, y-axis 0.11% FS, z-axis 0.15% FS and a noise density of x-axis 250 pT/Hz1/2 (at 1 Hz, y-axis 240 pT/Hz1/2 (at 1 Hz, z-axis 250 pT/Hz1/2 (at 1 Hz, respectively. This work has a less power consumption, a smaller size, and higher resolution than other miniaturized magnetometers by comparison.

  7. Miniaturized integration of a fluorescence microscope

    Science.gov (United States)

    Ghosh, Kunal K.; Burns, Laurie D.; Cocker, Eric D.; Nimmerjahn, Axel; Ziv, Yaniv; Gamal, Abbas El; Schnitzer, Mark J.

    2013-01-01

    The light microscope is traditionally an instrument of substantial size and expense. Its miniaturized integration would enable many new applications based on mass-producible, tiny microscopes. Key prospective usages include brain imaging in behaving animals towards relating cellular dynamics to animal behavior. Here we introduce a miniature (1.9 g) integrated fluorescence microscope made from mass-producible parts, including semiconductor light source and sensor. This device enables high-speed cellular-level imaging across ∼0.5 mm2 areas in active mice. This capability allowed concurrent tracking of Ca2+ spiking in >200 Purkinje neurons across nine cerebellar microzones. During mouse locomotion, individual microzones exhibited large-scale, synchronized Ca2+ spiking. This is a mesoscopic neural dynamic missed by prior techniques for studying the brain at other length scales. Overall, the integrated microscope is a potentially transformative technology that permits distribution to many animals and enables diverse usages, such as portable diagnostics or microscope arrays for large-scale screens. PMID:21909102

  8. Ultra-miniature wireless temperature sensor for thermal medicine applications.

    Science.gov (United States)

    Khairi, Ahmad; Hung, Shih-Chang; Paramesh, Jeyanandh; Fedder, Gary; Rabin, Yoed

    2011-01-01

    This study presents a prototype design of an ultra-miniature, wireless, battery-less, and implantable temperature-sensor, with applications to thermal medicine such as cryosurgery, hyperthermia, and thermal ablation. The design aims at a sensory device smaller than 1.5 mm in diameter and 3 mm in length, to enable minimally invasive deployment through a hypodermic needle. While the new device may be used for local temperature monitoring, simultaneous data collection from an array of such sensors can be used to reconstruct the 3D temperature field in the treated area, offering a unique capability in thermal medicine. The new sensory device consists of three major subsystems: a temperature-sensing core, a wireless data-communication unit, and a wireless power reception and management unit. Power is delivered wirelessly to the implant from an external source using an inductive link. To meet size requirements while enhancing reliability and minimizing cost, the implant is fully integrated in a regular foundry CMOS technology (0.15 μm in the current study), including the implant-side inductor of the power link. A temperature-sensing core that consists of a proportional-to-absolute-temperature (PTAT) circuit has been designed and characterized. It employs a microwatt chopper stabilized op-amp and dynamic element-matched current sources to achieve high absolute accuracy. A second order sigma-delta (Σ-Δ) analog-to-digital converter (ADC) is designed to convert the temperature reading to a digital code, which is transmitted by backscatter through the same antenna used for receiving power. A high-efficiency multi-stage differential CMOS rectifier has been designed to provide a DC supply to the sensing and communication subsystems. This paper focuses on the development of the all-CMOS temperature sensing core circuitry part of the device, and briefly reviews the wireless power delivery and communication subsystems.

  9. Miniature ambulatory skin conductance monitor and algorithm for investigating hot flash events

    Energy Technology Data Exchange (ETDEWEB)

    Bahr, Dennis E; Webster, John G; Shults, Mark [Department of Research and Development, Bahr Management, Inc., Middleton, WI 53562 (United States); Grady, Deborah; Creasman, Jennifer; Macer, Judy [Department of Medicine, University of California, San Francisco, CA 94115 (United States); Kronenberg, Fredi [School of Medicine, Stanford University, Palo Alto, CA 94305 (United States); Tyler, Mitchell; Zhou, Xin [Department of Biomedical Engineering, University of Wisconsin, Madison, WI 53706 (United States)

    2014-02-15

    A skin conductance monitoring system was developed and shown to reliably acquire and record hot flash events in both supervised laboratory and unsupervised ambulatory conditions. The 7.2 × 3.8 × 1.2 cm{sup 3} monitor consists of a disposable adhesive patch supporting two hydrogel electrodes and a reusable, miniaturized, enclosed electronic circuit board that snaps onto the electrodes. The monitor measures and records the skin conductance for seven days without external wires or telemetry and has an event marker that the subject can press whenever a hot flash is experienced. The accuracy of the system was demonstrated by comparing the number of hot flashes detected by algorithms developed during this research with the number identified by experts in hot flash studies. Three methods of detecting hot flash events were evaluated, but only two were fully developed. The two that were developed were an artificial neural network and a matched filter technique with multiple kernels implemented as a sliding form of the Pearson product-moment correlation coefficient. Both algorithms were trained on a ‘development’ cohort of 17 women and then validated using a second similar ‘validation’ cohort of 20. All subjects were between the ages of 40 and 60 and self-reported ten or more hot flashes per day over a three day period. The matched filter was the most accurate with a mean sensitivity of 0.92 and a mean specificity of 0.90 using the data from the development cohort and a mean sensitivity of 0.92 and a mean specificity of 0.87 using the data from the validation cohort. The matched filter was the method implemented in our processing software. (paper)

  10. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  11. Apollo experience report: Development flight instrumentation. [telemetry equipment for space flight test program

    Science.gov (United States)

    Farmer, N. B.

    1974-01-01

    Development flight instrumentation was delivered for 25 Apollo vehicles as Government-furnished equipment. The problems and philosophies of an activity that was concerned with supplying telemetry equipment to a space-flight test program are discussed. Equipment delivery dates, system-design details, and flight-performance information for each mission also are included.

  12. Telemetry Option in the Measurement of Physical Activity for Patients with Heart Failure

    Science.gov (United States)

    Melczer, Csaba; Melczer, László; Oláh, András; Sélleyné-Gyúró, Mónika; Welker, Zsanett; Ács, Pongrác

    2015-01-01

    Measurement of physical activity among patients with heart failure typically requires a special approach due to the patients' physical status. Nowadays, a technology is already available that can measure the kinematic movements in 3-D by a pacemaker and implantable defibrillator giving an assessment on software. The telemetry data can be…

  13. Miniature magnetic fluid seal working in liquid environments

    Energy Technology Data Exchange (ETDEWEB)

    Mitamura, Yoshinori, E-mail: ymitamura@par.odn.ne.jp [Graduate School of Information Science and Technology, Hokkaido University, Sapporo 060-0814 (Japan); Durst, Christopher A., E-mail: chris@procyrion.com [Procyrion, Inc., Houston, TX 77027 (United States)

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump. - Highlights: • A miniature magnetic fluid seal working in a liquid environment was developed. • The seal can be installed on Ø1 mm shaft and can seal against 370 mmHg at 40000 rpm. • The magnetic fluid seal will be useful for a catheter blood pump.

  14. Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview.

    Science.gov (United States)

    Nazario, Carlos E D; Silva, Meire R; Franco, Maraíssa S; Lanças, Fernando M

    2015-11-20

    The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps. The mass spectrometry as detection system is the most widely used detection system; among many alternative ionization sources direct-EI LC-MS is a promising alternative to APCI. In addition, capillary columns are now available showing many possibilities of stationary phases, inner diameters and hardware materials. This review provides a discussion about miniaturized LC demonstrating fundamentals and instrumentals' aspects of the commercially available miniaturized LC instrumental system mainly nano and micro LC formats. This review also covers the recent developments and trends in instrumentation, capillary and nano columns, and several applications of this very important and promising field. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

    OpenAIRE

    Hyun Jin Kim; Hyun Nam Kim; Hamid Saeed Raza; Han Beom Park; Sung Oh Cho

    2016-01-01

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be ...

  16. Miniature fiber Bragg grating sensor interrogator (FBG-Transceiver) system

    Science.gov (United States)

    Mendoza, Edgar A.; Kempen, Cornelia; Lopatin, Craig

    2007-04-01

    This paper describes recent progress conducted towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-Transceiver TM) system based on multi-channel integrated optic sensor (InOSense TM) microchip technology. The hybrid InOSense TM microchip technology enables the integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogator systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation. The FBG-Transceiver system uses active optoelectronic components monolithically integrated to the InOSense TM microchip, a microprocessor controlled signal processing electronics board capable of processing the FBG sensors signals related to stress-strain and temperature as well as vibration and acoustics. The FBG-Transceiver TM system represents a new, reliable, highly robust technology that can be used to accurately monitor the status of an array of distributed fiber optic Bragg grating sensors installed in critical infrastructures. Its miniature package, low power operation, and state-of-the-art data communications architecture, all at a very affordable price makes it a very attractive solution for a large number of SHM/NDI applications in aerospace, naval and maritime industry, civil structures like bridges, buildings and dams, the oil and chemical industry, and for homeland security applications. The miniature, cost-efficient FBG-Transceiver TM system is poised to revolutionize the field of structural health monitoring and nondestructive inspection market. The sponsor of this program is NAVAIR under a DOD SBIR contract.

  17. MIT miniaturized disk bend test

    International Nuclear Information System (INIS)

    Harling, O.K.; Lee, M.; Sohn, D.S.; Kohse, G.; Lau, C.W.

    1983-01-01

    A miniaturized disk bend test (MDBT) using transmission electron microscopy specimens for the determination of various mechanical properties is being developed at MIT. Recent progress in obtaining strengths and ductilities of highly irradiated metal alloys is reviewed. Other mechanical properties can also be obtained using the MDBT approach. Progress in fatigue testing and in determination of the ductile-to-brittle transition temperature is reviewed briefly. 11 figures

  18. High prevalence of the c.74A>C SPINK1 variant in miniature and standard Schnauzers.

    Science.gov (United States)

    Furrow, E; Armstrong, P J; Patterson, E E

    2012-01-01

    Variants in the serine protease inhibitor Kazal type 1 (SPINK1) gene have been associated with pancreatitis in Miniature Schnauzers. Replication of the association in an independent population is necessary to determine if genetic screening for SPINK1 variants should be considered in clinical practice. An association between the SPINK1 exonic variant c.74A > C and pancreatitis exists in Miniature Schnauzers. In addition, the variant is absent or rare in Standard Schnauzers, a related breed that is not reported to have an increased risk for pancreatitis. Case-control study. Seventeen Miniature Schnauzers with pancreatitis (cases), 60 mature Miniature Schnauzers with no substantial history of gastrointestinal signs in their lifetime (controls), and 31 Standard Schnauzers of unknown pancreatitis status. A PCR-RFLP assay was used to genotype dogs for the c.74A > C SPINK1 variant. Allele and genotype frequencies were reported for Schnauzers and compared between case and control Miniature Schnauzers. The c.74A > C variant was the major allele in both Schnauzer breeds with a frequency of 0.77 in Miniatures and 0.55 in Standards. The allele and genotype frequencies were similar between Miniature Schnauzers with and without a history of pancreatitis and did not impart an increased risk for pancreatitis. Genotyping a larger population of the Miniature Schnauzer breed than a previous study, along with a Standard Schnauzer cohort, demonstrated that the SPINK1 c.74A > C variant is a common polymorphism in the Schnauzer lineage. Furthermore, we were unable to confirm a relationship between the variant and clinically detectable pancreatitis in Miniature Schnauzers. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  19. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  20. Miniature fiber-optic multiphoton microscopy system using frequency-doubled femtosecond Er-doped fiber laser.

    Science.gov (United States)

    Huang, Lin; Mills, Arthur K; Zhao, Yuan; Jones, David J; Tang, Shuo

    2016-05-01

    We report on a miniature fiber-optic multiphoton microscopy (MPM) system based on a frequency-doubled femtosecond Er-doped fiber laser. The femtosecond pulses from the laser source are delivered to the miniature fiber-optic probe at 1.58 µm wavelength, where a standard single mode fiber is used for delivery without the need of free-space dispersion compensation components. The beam is frequency-doubled inside the probe by a periodically poled MgO:LiNbO3 crystal. Frequency-doubled pulses at 786 nm with a maximum power of 80 mW and a pulsewidth of 150 fs are obtained and applied to excite intrinsic signals from tissues. A MEMS scanner, a miniature objective, and a multimode collection fiber are further used to make the probe compact. The miniature fiber-optic MPM system is highly portable and robust. Ex vivo multiphoton imaging of mammalian skins demonstrates the capability of the system in imaging biological tissues. The results show that the miniature fiber-optic MPM system using frequency-doubled femtosecond fiber laser can potentially bring the MPM imaging for clinical applications.

  1. Plans for miniature machining at LASL

    International Nuclear Information System (INIS)

    Rhorer, R.L.

    1979-01-01

    A special shop for making miniature or very small parts is being established within the LASL Shop Department, and one of the machine tools for this shop is a high precision lathe. The report describes a method based on scale modeling analysis which was used to define the specific requirements for this lathe

  2. Fabrication of a Miniaturized ZnO Nanowire Accelerometer and Its Performance Tests

    Directory of Open Access Journals (Sweden)

    Hyun Chan Kim

    2016-09-01

    Full Text Available This paper reports a miniaturized piezoelectric accelerometer suitable for a small haptic actuator array. The accelerometer is made with zinc oxide (ZnO nanowire (NW grown on a copper wafer by a hydrothermal process. The size of the accelerometer is 1.5 × 1.5 mm2, thus fitting the 1.8 × 1.8 mm2 haptic actuator array cell. The detailed fabrication process of the miniaturized accelerometer is illustrated. Performance evaluation of the fabricated accelerometer is conducted by comparing it with a commercial piezoelectric accelerometer. The output current of the fabricated accelerometer increases linearly with the acceleration. The miniaturized ZnO NW accelerometer is feasible for acceleration measurement of small and lightweight devices.

  3. Miniaturized Airborne Imaging Central Server System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a miniaturized airborne imaging central server system (MAICSS). MAICSS is designed as a high-performance-computer-based electronic backend that...

  4. Miniaturized Airborne Imaging Central Server System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation is a miniaturized airborne imaging central server system (MAICSS). MAICSS is designed as a high-performance computer-based electronic backend that...

  5. Miniaturized optical sensors based on lens arrays

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, M.L.; Larsen, H.E.

    2005-01-01

    A suite of optical sensors based on the use of lenticular arrays for probing mechanical deflections will be displayed. The optical systems are well suited for miniaturization, and utilize speckles as the information-carriers. This implementation allows for acquiring directional information...

  6. Miniature Inertial and Augmentation Sensors for Integrated Inertial/GPS Based Navigation Applications

    Science.gov (United States)

    2010-03-01

    Magnetometer (Ref [23]) Until miniature atomic magnetometers transition from laboratory demonstration units to a mass produced product, fluxgate ...and/or magnetoresistive designs are a better suited magnetometer technology for a miniature navigation system. Figure 8 below shows the basic fluxgate ...is required to resolve magnetic field orientation. Fig 8. Fluxgate Magnetometer Schematic The PNI Sensor Corporation (Santa Rosa, CA

  7. Analisis Jangkauan Dan Baud Rate Transmisi Data Pada Sistem Telemetri Temperatur Berbasis Mikrokontroler

    Directory of Open Access Journals (Sweden)

    Nurjannah

    2016-06-01

    Full Text Available Pengujian jangkauan dan boud rate transmisi data pada sistem telemetri temperatur dilakukan untuk menganalisis pengaruhnya terhadap data yang ditransmisikan.. Alat-alat yang digunakan untuk menganalisisnya adalah sensor temperatur LM35, perangkat transmitter, perangkat receiver dan PC. Adapun metode yang dilakukan untuk pengujian jangkauan transmisi data adalah dengan cara mentransmisikan data pada jangkauan 1 meter sampai dengan 10 meter. Sedangkan untuk melakukan pengujian pengaruh boud rate terhadap data yang ditransmisikan dilakukan dengan cara memvariasikan boud rate perangkat receiver pada setiap transmisi data. Testing of the extent and baud rate of data transmission on temperature telemetry system was conducted to analyze its effect to the transmitted data. The tools that was used to analyze it was LM35 temperature sensor, transmitter devices, receiver devices and PC. The method that was carried out to test the extent of the data transmission was by transmiting data on a range of 1 meter to 10 meters. As for testing the effect of baud rate against data that was transmitted was done by varying the baud rate on receiver device at any transmission of data.

  8. Novel Miniature Spectrometer For Remote Chemical Detection

    International Nuclear Information System (INIS)

    Pipino, Andrew C.R.

    2000-01-01

    New chemical sensing technologies are critically important for addressing many of EM's priority needs as discussed in detail at http://emsp.em.doe.gov/needs. Many technology needs were addressed by this research. For example, improved detection strategies are needed for non-aqueous phase liquids (NAPL's), such as PCE (Cl2C=CCl2) and TCE (HClC=CCl2), which persist in the environment due their highly stable structures. By developing a miniature, ultra-sensitive, selective, and field-deployable detector for NAPL's, the approximate source location could be determined with minimal investigative expense. Contaminant plumes could also be characterized in detail. The miniature spectrometer developed under Project No.60231 could also permit accurate rate measurements in less time, either in the field or the laboratory, which are critically important in the development, testing, and ultimate utilization of models for describing contaminant transport. The technology could also be used for long-term groundwater monitoring or long-term stewardship in general. Many science needs are also addressed by the Project 60231, since the effort significantly advances the measurement science of chemical detection. Developed under Project No.60231, evanescent wave cavity ring-down spectroscopy (EW-CRDS) is a novel form of CRDS, which is an the emerging optical absorption technique. Several review articles on CRDS, which has been generally applied only to gas-phase diagnostics, have been published1-3. EW-CRDS4-10 forms the basis for a new class of chemical sensors that extends CRDS to other states of matter and leads to a miniaturized version of the concept. EW-CRDS uses miniature solid-state optical resonators that incorporate one or more total internal reflection (TIR) surfaces, which create evanescent waves. The evanescent waves emanate from the TIR surfaces, sampling the surrounding medium. The utility of evanescent waves in chemical analysis forms the basis for the field of attenuated

  9. Telemetry Physical Activity Monitoring in Minipig’s Model of Huntington’s Disease

    Czech Academy of Sciences Publication Activity Database

    Pokorný, M.; Juhás, Štefan; Juhásová, Jana; Klíma, Jiří; Motlík, Jan; Klempíř, J.; Havlík, J.

    2015-01-01

    Roč. 78, Suppl 2 (2015), s. 39-42 ISSN 1210-7859. [Conference on Animal Models for neurodegenerative Diseases /3./. Liblice, 08.11.2015-10.11.2015] R&D Projects: GA MŠk ED2.1.00/03.0124; GA MŠk(CZ) 7F14308 Institutional support: RVO:67985904 Keywords : Huntington´s disease * minipig * telemetry Subject RIV: FH - Neurology Impact factor: 0.209, year: 2015

  10. Inherited retinal dysplasia and persistent hyperplastic primary vitreous in Miniature Schnauzer dogs.

    Science.gov (United States)

    Grahn, Bruce H; Storey, Eric S; McMillan, Catherine

    2004-01-01

    The objectives of this study were to define the clinical syndrome of retinal dysplasia and persistent primary vitreous in Miniature Schnauzer dogs and determine the etiology. We examined 106 Miniature Schnauzers using a biomicroscope and indirect ophthalmoscope. The anterior and posterior segments of affected dogs were photographed. Four enucleated eyes were examined using routine light microscopy and scanning electron microscopy. A pedigree was constructed and related dogs were test-bred to define the mode of inheritance of this syndrome. Congenital retinal dysplasia was confirmed in 24 of 106 related Miniature Schnauzer dogs. Physical and postmortem examinations revealed that congenital abnormalities were limited to the eyes. Biomicroscopic, indirect ophthalmoscopic, and neuro-ophthalmic examinations confirmed that some of these dogs were blind secondary to bilateral retinal dysplasia and detachment (nonattachment) (n = 13), and the remainder had generalized retinal dysplasia (n = 11). Fifteen of these dogs were also diagnosed with unilateral (n = 9) or bilateral (n = 6) persistent hyperplastic primary vitreous. Nutritional, infectious, or toxic etiologies were not evident on physical, postmortem, light microscopic, or transmitting and scanning electron microscopic examination of four affected Miniature Schnauzers. We examined the pedigree and determined that an autosomal recessive mode of inheritance was most likely. Three test-bred litters including those from affected parents, carrier and affected parents, and carrier parents confirmed this mode of inheritance. This study confirms that retinal dysplasia and persistent hyperplastic primary vitreous is a congenital abnormality that is inherited as an autosomal recessive condition in Miniature Schnauzers.

  11. An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

    Directory of Open Access Journals (Sweden)

    Hyun Jin Kim

    2016-06-01

    Full Text Available A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  12. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh

    2016-01-01

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube

  13. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  14. Near-net shape manufacturing of miniature spur gears by wire spark erosion machining

    CERN Document Server

    Gupta, Kapil

    2016-01-01

    This work describes an experimental investigation with the aim to evaluate and establish wire spark erosion machining (WSEM) as a viable alternative for high quality miniature gear manufacturing. External spur type miniature brass (ASTM 858) gears with 12 teeth, 9.8 mm outside diameter and 5 mm face width were manufactured by WSEM. The research work was accomplished in four distinct experimental stages viz., preliminary, pilot, main and confirmation. The aim, scope and findings of each stage are progressively presented and discussed. In essence, the investigation found that it was possible to manufacture miniature gears to high quality by using WSEM. Gears up to DIN 5 quality with a good surface finish (1.2 µm average roughness) and satisfactory surface integrity were achieved. The results suggest that WSEM should be considered a viable alternative to conventional miniature gear manufacturing techniques and that in some instances it may even be superior. This work will prove useful to researchers and profess...

  15. Digital Microfluidics for Nucleic Acid Amplification

    Directory of Open Access Journals (Sweden)

    Beatriz Coelho

    2017-06-01

    Full Text Available Digital Microfluidics (DMF has emerged as a disruptive methodology for the control and manipulation of low volume droplets. In DMF, each droplet acts as a single reactor, which allows for extensive multiparallelization of biological and chemical reactions at a much smaller scale. DMF devices open entirely new and promising pathways for multiplex analysis and reaction occurring in a miniaturized format, thus allowing for healthcare decentralization from major laboratories to point-of-care with accurate, robust and inexpensive molecular diagnostics. Here, we shall focus on DMF platforms specifically designed for nucleic acid amplification, which is key for molecular diagnostics of several diseases and conditions, from pathogen identification to cancer mutations detection. Particular attention will be given to the device architecture, materials and nucleic acid amplification applications in validated settings.

  16. Technologies for highly miniaturized autonomous sensor networks

    NARCIS (Netherlands)

    Baert, K.; Gyselinckx, B.; Torfs, T.; Leonov, V.; Yazicioglu, F.; Brebels, S.; Donnay, S.; Vanfleteren, J.; Beyne, E.; Hoof, C. van

    2006-01-01

    Recent results of the autonomous sensor research program HUMAN++ will be summarized in this paper. The research program aims to achieve highly miniaturized and (nearly) autonomous sensor systems that assist our health and comfort. Although the application examples are dedicated to human

  17. Miniaturized measurement system for ammonia in air

    NARCIS (Netherlands)

    Timmer, B.H.; van Delft, K.M.; Otjes, R.P.; Olthuis, Wouter; van den Berg, Albert

    2004-01-01

    The development of a miniaturized ammonia sensor made using microsystem technology is described. Gas is sampled in a sampler comprising two opposite channels separated by a gas permeable, water repellent polypropylene membrane. Subsequently, the acid sample solution is pumped into a selector where

  18. Miniaturized Charpy test for reactor pressure vessel embrittlement characterization

    Energy Technology Data Exchange (ETDEWEB)

    Manahan, M.P. Sr. [MPM Research and Consulting, Lemont, PA (United States)

    1999-10-01

    Modifications were made to a conventional Charpy machine to accommodate the miniaturized Charpy V-Notch (MCVN) specimens which were fabricated from an archived reactor pressure vessel (RPV) steel. Over 100 dynamic MCVN tests were performed and compared to the results from conventional Charpy V-Notch (CVN) tests to demonstrate the efficacy of the miniature specimen test. The optimized sidegrooved MCVN specimens exhibit transitional fracture behavior over essentially the same temperature range as the CVN specimens which indicates that the stress fields in the MCVN specimens reasonably simulate those of the CVN specimens and this fact has been observed in finite element calculations. This result demonstrates a significant breakthrough since it is now possible to measure the ductile-brittle transition temperature (DBTT) using miniature specimens with only small correction factors, and for some materials as in the present study, without the need for any correction factor at all. This development simplifies data interpretation and will facilitate future regulatory acceptance. The non-sidegrooved specimens yield energy-temperature data which is significantly shifted downward in temperature (non-conservative) as a result of the loss of constraint which accompanies size reduction.

  19. SMARBot: a modular miniature mobile robot platform

    Science.gov (United States)

    Meng, Yan; Johnson, Kerry; Simms, Brian; Conforth, Matthew

    2008-04-01

    Miniature robots have many advantages over their larger counterparts, such as low cost, low power, and easy to build a large scale team for complex tasks. Heterogeneous multi miniature robots could provide powerful situation awareness capability due to different locomotion capabilities and sensor information. However, it would be expensive and time consuming to develop specific embedded system for different type of robots. In this paper, we propose a generic modular embedded system architecture called SMARbot (Stevens Modular Autonomous Robot), which consists of a set of hardware and software modules that can be configured to construct various types of robot systems. These modules include a high performance microprocessor, a reconfigurable hardware component, wireless communication, and diverse sensor and actuator interfaces. The design of all the modules in electrical subsystem, the selection criteria for module components, and the real-time operating system are described. Some proofs of concept experimental results are also presented.

  20. Mobile Vending - Benefit and limits of vending machines by using telemetry

    OpenAIRE

    Heinkele, Christian; Pousttchi, Key; Legler, Steffen

    2004-01-01

    The use of telemetry via wireless communication technique is able to support the process of operating vending machines. The advantages on appropriate kinds of vending machines can be achieved by using a demand-driven instead of a trigger-driven provisioning as well as a trouble-shooting in real time. The availability of reliable telemetrically collected real time data enhance the analysis and optimization of the supply in vending machines and the profitability of vending machine places, too. ...

  1. A Low Noise CMOS Readout Based on a Polymer-Coated SAW Array for Miniature Electronic Nose

    Directory of Open Access Journals (Sweden)

    Cheng-Chun Wu

    2016-10-01

    Full Text Available An electronic nose (E-Nose is one of the applications for surface acoustic wave (SAW sensors. In this paper, we present a low-noise complementary metal–oxide–semiconductor (CMOS readout application-specific integrated circuit (ASIC based on an SAW sensor array for achieving a miniature E-Nose. The center frequency of the SAW sensors was measured to be approximately 114 MHz. Because of interference between the sensors, we designed a low-noise CMOS frequency readout circuit to enable the SAW sensor to obtain frequency variation. The proposed circuit was fabricated in Taiwan Semiconductor Manufacturing Company (TSMC 0.18 μm 1P6M CMOS process technology. The total chip size was nearly 1203 × 1203 μm2. The chip was operated at a supply voltage of 1 V for a digital circuit and 1.8 V for an analog circuit. The least measurable difference between frequencies was 4 Hz. The detection limit of the system, when estimated using methanol and ethanol, was 0.1 ppm. Their linearity was in the range of 0.1 to 26,000 ppm. The power consumption levels of the analog and digital circuits were 1.742 mW and 761 μW, respectively.

  2. A miniature spark counter for public communication and education

    International Nuclear Information System (INIS)

    Mao, C.H.; Weng, P.S.

    1987-01-01

    The fabrication of a miniature spark counter for public communication and education using naturally occurring radon as a radioactive source without involving any man-made radioactivity is described. The battery-powered miniature spark counter weighs 2.07 kg with a volume of 4.844 x 10/sup -4/ m/sup 3/. The circuitry consists of seven major components: timer, high-voltage power supply, attenuator, noninverting amplifier, low-pass filter, one-shot generator, and counter. Cellulose nitrate films irradiated with alpha particles from radon emanating from soil were etched and counted. The visible sparks during counting are rather heuristic, which can be used to demonstrate naturally occurring radioactivity in classrooms or showplaces

  3. Lobar holoprosencephaly in a Miniature Schnauzer with hypodipsic hypernatremia.

    Science.gov (United States)

    Sullivan, Stacey A; Harmon, Barry G; Purinton, P Thomas; Greene, Craig E; Glerum, Leigh E

    2003-12-15

    A 9-month-old male Miniature Schnauzer was examined because of a lifelong history of behavioral abnormalities, including hypodipsia. Diagnostic evaluation revealed marked hypernatremia and a single forebrain ventricle. The behavioral abnormalities did not resolve with correction of the hypernatremia, and the dog was euthanatized. At necropsy, midline forebrain structures were absent or reduced in size, and normally paired forebrain structures were incompletely separated. Findings were diagnostic for holoprosencephaly, a potentially genetic disorder and the likely cause of the hypodipsia. Similar evaluation of affected Miniature Schnauzer dogs may reveal whether holoprosencephaly routinely underlies the thirst deficiency that may be seen in dogs of this breed.

  4. Miniature Sensor for Aerosol Mass Measurements, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR project seeks to develop a miniature sensor for mass measurement of size-classified aerosols. A cascade impactor will be used to classify aerosol sample...

  5. Miniaturized radiation detector with custom synthesized diamond crystal as sensor

    International Nuclear Information System (INIS)

    Grobbelaar, J.H.; Burns, R.C.; Nam, T.L.; Keddy, R.J.

    1991-01-01

    A miniaturized detector consisting of three custom built hybrid circuits, a counter and a miniature high voltage power supply was designed to operate with custom synthesized Type Ib diamond crystals as sensors. Thick-film technology was incorporated in the circuit design. With a crystal having a volume of approximately 10 mm 3 and containing approximately 60 ppm paramagnetic nitrogen, the detector was capable of measuring γ-ray dose-rates as low as 7.5 μ Gy h -1 . The response characteristic was linear up to 1 cGy h -1 . (orig.)

  6. Fabrication of miniaturized electrostatic deflectors using LIGA

    International Nuclear Information System (INIS)

    Jackson, K.H.; Khan-Malek, C.; Muray, L.P.

    1997-01-01

    Miniaturized electron beam columns (open-quotes microcolumnsclose quotes) have been demonstrated to be suitable candidates for scanning electron microscopy (SEM), e-beam lithography and other high resolution, low voltage applications. In the present technology, microcolumns consist of open-quotes selectively scaledclose quotes micro-sized lenses and apertures, fabricated from silicon membranes with e-beam lithography, reactive ion beam etching and other semiconductor thin-film techniques. These miniaturized electron-optical elements provide significant advantages over conventional optics in performance and ease of fabrication. Since lens aberrations scale roughly with size, it is possible to fabricate simple microcolumns with extremely high brightness sources and electrostatic objective lenses, with resolution and beam current comparable to conventional e-beam columns. Moreover since microcolumns typically operate at low voltages (1 KeV), the proximity effects encountered in e-beam lithography become negligible. For high throughput applications, batch fabrication methods may be used to build large parallel arrays of microcolumns. To date, the best reported performance with a 1 keV cold field emission cathode, is 30 nm resolution at a working distance of 2mm in a 3.5mm column. Fabrication of the microcolumn deflector and stigmator, however, have remained beyond the capabilities of conventional machining operations and semiconductor processing technology. This work examines the LIGA process as a superior alternative to fabrication of the deflectors, especially in terms of degree of miniaturization, dimensional control, placement accuracy, run-out, facet smoothness and choice of suitable materials. LIGA is a combination of deep X-ray lithography, electroplating, and injection molding processes which allow the fabrication of microstructures

  7. Focal Segmental Glomerulosclerosis in Related Miniature Schnauzer Dogs.

    Science.gov (United States)

    Yau, Wilson; Mausbach, Lisa; Littman, Meryl P; Cianciolo, Rachel E; Brown, Cathy A

    2018-03-01

    Focal segmental glomerulosclerosis (FSGS) recently has been recognized as a common cause of proteinuria in dogs in general, and in Miniature Schnauzer dogs in particular. This study describes the morphologic features present in the kidneys of 8 related proteinuric Miniature Schnauzer dogs. The FSGS, characterized by solidification of portions of the capillary tuft, affected 32% to 49% of examined glomeruli in these dogs. Synechiae, often accompanied by hyalinosis, were present in 13% to 54% of glomeruli and were more prevalent in older dogs. Seven of 8 dogs had arteriolar hyalinosis. Ultrastructurally, all dogs had evidence of a podocytopathy in the absence of electron-dense deposits, glomerular basement membrane splitting, or fibrils. All dogs had multifocal to extensive podocyte foot process effacement. Other podocyte changes included microvillous transformation, the presence of vacuoles or protein resorption droplets, cytoplasmic electron-dense aggregates, and occasional binucleation. Variable amounts of intraglomerular lipid were present in all dogs. All dogs were proteinuric, with measured values for the urine protein-to-creatinine ratio ranging from 1.2 to 6.5. Azotemia was mild to absent and dogs were euthanatized at 5.1 to 14 years of age, in all cases due to nonrenal diseases. The underlying cause of FSGS in these Miniature Schnauzer dogs has yet to be determined, but contributors likely include genetic podocytopathy, lipid abnormalities, and glomerular hypertension.

  8. Optimal and Miniaturized Strongly Coupled Magnetic Resonant Systems

    Science.gov (United States)

    Hu, Hao

    Wireless power transfer (WPT) technologies for communication and recharging devices have recently attracted significant research attention. Conventional WPT systems based either on far-field or near-field coupling cannot provide simultaneously high efficiency and long transfer range. The Strongly Coupled Magnetic Resonance (SCMR) method was introduced recently, and it offers the possibility of transferring power with high efficiency over longer distances. Previous SCMR research has only focused on how to improve its efficiency and range through different methods. However, the study of optimal and miniaturized designs has been limited. In addition, no multiband and broadband SCMR WPT systems have been developed and traditional SCMR systems exhibit narrowband efficiency thereby imposing strict limitations on simultaneous wireless transmission of information and power, which is important for battery-less sensors. Therefore, new SCMR systems that are optimally designed and miniaturized in size will significantly enhance various technologies in many applications. The optimal and miniaturized SCMR systems are studied here. First, analytical models of the Conformal SCMR (CSCMR) system and thorough analysis and design methodology have been presented. This analysis specifically leads to the identification of the optimal design parameters, and predicts the performance of the designed CSCMR system. Second, optimal multiband and broadband CSCMR systems are designed. Two-band, three-band, and four-band CSCMR systems are designed and validated using simulations and measurements. Novel broadband CSCMR systems are also analyzed, designed, simulated and measured. The proposed broadband CSCMR system achieved more than 7 times larger bandwidth compared to the traditional SCMR system at the same frequency. Miniaturization methods of SCMR systems are also explored. Specifically, methods that use printable CSCMR with large capacitors, novel topologies including meandered, SRRs, and

  9. Experimental induction of struvite uroliths in miniature schnauzer and beagle dogs.

    Science.gov (United States)

    Klausner, J S; Osborne, C A; O'Leary, T P; Muscoplat, C M; Griffith, D P

    1980-09-01

    Urease positive staphylococcal urinary tract infection was experimentally induced in 13 dogs. Eight dogs developed cystic and/or urethral struvite calculi in 2 to 8 weeks. No abnormalities in systemic cell mediated immunity were detected in dogs before or after the establishment of the urinary tract infection. Miniature schnauzers whose ancestors had developed stones seemed to be no more susceptible to experimental urinary tract infection and stone formation than miniature schnauzers or beagles whose ancestors did not develop stones.

  10. A new miniaturized negative-index meta-atom for tri-band applications

    Directory of Open Access Journals (Sweden)

    Hossain Mohammad Jakir

    2017-07-01

    Full Text Available In this paper, a miniature negative index meta-atom was designed; simulated, fabricated and measured based on parallel incidence of electromagnetic wave that can maintain a tri-band applications in microwave spectra. Compare to the other multi-band conventional metamaterial, the proposed meta-atom structure allows miniaturization factor and follows better effective medium ratio (EMR. Finite-integration technique (FIT based computer simulation technology (CST electromagnetic simulator was adopted to examine the design of the meta-atom. It exhibits tri-band response in conjunction with backward wave property over a certain frequency band in the microwave regime. Furthermore, the effective medium ratio is considerably improved compared to previously reported metamaterial. Moreover, few parametric analyses were done with the meta-atom. The size, scattering parameters and effective medium parameters of the proposed negative index miniaturized meta-atom is appropriate for tri-band applications.

  11. Wavefront division digital holography

    Science.gov (United States)

    Zhang, Wenhui; Cao, Liangcai; Li, Rujia; Zhang, Hua; Zhang, Hao; Jiang, Qiang; Jin, Guofan

    2018-05-01

    Digital holography (DH), mostly Mach-Zehnder configuration based, belongs to non-common path amplitude splitting interference imaging whose stability and fringe contrast are environmental sensitive. This paper presents a wavefront division DH configuration with both high stability and high-contrast fringes benefitting from quasi common path wavefront-splitting interference. In our proposal, two spherical waves with similar curvature coming from the same wavefront are used, which makes full use of the physical sampling capacity of the detectors. The interference fringe spacing can be adjusted flexibly for both in-line and off-axis mode due to the independent modulation to these two waves. Only a few optical elements, including the mirror-beam splitter interference component, are used without strict alignments, which makes it robust and easy-to-implement. The proposed wavefront division DH promotes interference imaging physics into the practical and miniaturized a step forward. The feasibility of this method is proved by the imaging of a resolution target and a water flea.

  12. Miniaturization of high-energy physics detectors. Vol. 14

    International Nuclear Information System (INIS)

    Stefanini, A.

    1983-01-01

    Continued experimental research in high-energy physics requires the reduction in size and cost of the advanced technical equipment involved. A new technology is rapidly evolving that promises to replace today's massive high-energy physics instruments--which may be composed of several thousand tons of sensitive parts--with miniaturized equivalents. Smaller, less expensive apparatus would create more opportunities for research worldwide, and many types of experiments now considered impractical could then be carried out. Scientists and engineers from many countries have contributed to this volume to provide a broad panorama of the new miniaturization technology in high-energy physics. They describe a wide range of new instruments and their applications, discuss limitations and technological problems, and explore the connections between technology and progress in the field of high-energy physics

  13. Effects of angling and manual handling on pike behaviour investigated by high-resolution positional telemetry

    DEFF Research Database (Denmark)

    Baktoft, Henrik; Aarestrup, Kim; Berg, Søren

    2013-01-01

    Human disturbances such as angling and manual handling may have long-term effects on the behaviour of pike, Esox lucius L., an ecologically important species. Using continuous high-resolution positional telemetry, this study compared the swimming activity of handled and unhandled pike in a small...

  14. X-36 on Ground after Radio and Telemetry Tests

    Science.gov (United States)

    1996-01-01

    A UH-1 helicopter lowers the X-36 Tailless Fighter Agility Research Aircraft to the ground after radio frequency and telemetry tests above Rogers Dry Lake at NASA Dryden Flight Research Center, Edwards, California, in November 1996. The purpose of taking the X-36 aloft for the radio and telemetry system checkouts was to test the systems more realistically while airborne. More taxi and radio frequency tests were conducted before the aircraft's first flight in early 1997. The NASA/Boeing X-36 Tailless Fighter Agility Research Aircraft program successfully demonstrated the tailless fighter design using advanced technologies to improve the maneuverability and survivability of possible future fighter aircraft. The program met or exceeded all project goals. For 31 flights during 1997 at the Dryden Flight Research Center, Edwards, California, the project team examined the aircraft's agility at low speed / high angles of attack and at high speed / low angles of attack. The aircraft's speed envelope reached up to 206 knots (234 mph). This aircraft was very stable and maneuverable. It handled very well. The X-36 vehicle was designed to fly without the traditional tail surfaces common on most aircraft. Instead, a canard forward of the wing was used as well as split ailerons and an advanced thrust-vectoring nozzle for directional control. The X-36 was unstable in both pitch and yaw axes, so an advanced, single-channel digital fly-by-wire control system (developed with some commercially available components) was put in place to stabilize the aircraft. Using a video camera mounted in the nose of the aircraft and an onboard microphone, the X-36 was remotely controlled by a pilot in a ground station virtual cockpit. A standard fighter-type head-up display (HUD) and a moving-map representation of the vehicle's position within the range in which it flew provided excellent situational awareness for the pilot. This pilot-in-the-loop approach eliminated the need for expensive and

  15. A Miniature Coupled Bistable Vibration Energy Harvester

    International Nuclear Information System (INIS)

    Zhu, D; Arthur, D C; Beeby, S P

    2014-01-01

    This paper reports the design and test of a miniature coupled bistable vibration energy harvester. Operation of a bistable structure largely depends on vibration amplitude rather than frequency, which makes it very promising for wideband vibration energy harvesting applications. A coupled bistable structure consists of a pair of mobile magnets that create two potential wells and thus the bistable phenomenon. It requires lower excitation to trigger bistable operation compared to conventional bistable structures. Based on previous research, this work focused on miniaturisation of the coupled bistable structure for energy harvesting application. The proposed bistable energy harvester is a combination of a Duffing's nonlinear structure and a linear assisting resonator. Experimental results show that the output spectrum of the miniature coupled bistable vibration energy harvester was the superposition of several spectra. It had a higher maximum output power and a much greater bandwidth compared to simply the Duffing's structure without the assisting resonator

  16. Naturalism and Mannerism in Indian Miniatures

    Science.gov (United States)

    Duran, Jane

    2001-01-01

    In this essay, the author furthers the argument that critical commentary on the Rajput and Muslim miniatures of India has focused on a rather odd use of labels and categories, perhaps to an even greater extent than has been the case with much of the rest of the criticism of the art of South Asia. She first examines the use of the term…

  17. Bend testing for miniature disks

    International Nuclear Information System (INIS)

    Huang, F.H.; Hamilton, M.L.; Wire, G.L.

    1982-01-01

    A bend test was developed to obtain ductility measurements on a large number of alloy variants being irradiated in the form of miniature disks. Experimental results were shown to be in agreement with a theoretical analysis of the bend configuration. Disk specimens fabricated from the unstrained grip ends of previously tested tensile specimens were used for calibration purposes; bend ductilities and tensile ductilities were in good agreement. The criterion for estimating ductility was judged acceptable for screening purposes

  18. Rays in the northern Gulf of Mexico: Aerial Survey and Satellite Telemetry 2008-2012 (NCEI Accession 0129495)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The dataset contains distribution and abundance data for rays in the Gulf of Mexico collected through aerial surveys and satellite telemetry. Aerial survey data...

  19. Miniaturization of Fresnel lenses for solar concentration: a quantitative investigation.

    Science.gov (United States)

    Duerr, Fabian; Meuret, Youri; Thienpont, Hugo

    2010-04-20

    Sizing down the dimensions of solar concentrators for photovoltaic applications offers a number of promising advantages. It provides thinner modules and smaller solar cells, which reduces thermal issues. In this work a plane Fresnel lens design is introduced that is first analyzed with geometrical optics. Because of miniaturization, pure ray tracing may no longer be valid to determine the concentration performance. Therefore, a quantitative wave optical analysis of the miniaturization's influence on the obtained concentration performance is presented. This better quantitative understanding of the impact of diffraction in microstructured Fresnel lenses might help to optimize the design of several applications in nonimaging optics.

  20. Comparison of Diagnostic Information from Regular Telemetry Equipment and a Novel Patch Type Electrocardiogram Recorder

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Hoppe, Karsten

    2014-01-01

    The purpose of this pilot study is to compare the diagnostic information obtained using regular telemetry equipment and the novel ePatch heart monitor. The comparison was conducted by a cardiologist on 24-hour recordings from 11 admitted patients. For all 11 recordings, the same diagnostic inform...

  1. Development, evaluation and implementation of video-EEG telemetry at home.

    Science.gov (United States)

    Brunnhuber, Franz; Amin, Devyani; Nguyen, Yan; Goyal, Sushma; Richardson, Mark P

    2014-05-01

    To describe the development and implementation of video EEG telemetry (VT) in the patient's home (home video telemetry, HVT) in a single centre. HVT met the UK Medical Research Council definition of a complex intervention, and we used its guidance to evaluate the process of piloting, evaluating, developing and implementing this new clinical service. The first phase was a feasibility study, comparing inpatient VT (IVT) with HVT in a test-retest design (n=5), to assess data quality and yield of clinically relevant events. The second phase was a pre-implementation study (n=8), to examine acceptability and satisfaction as well as the costs of IVT and HVT. Subsequently, we implemented the service, and reviewed the outcomes of the first 34 patients. The feasibility study found no difference in the quality of recording or clinical yield between IVT and HVT. The pre-implementation study showed excellent patient satisfaction. We also discuss the findings of the main stakeholder survey (consultants and technicians). Our economic modelling demonstrates a clear financial superiority of HVT over IVT. Our findings show that diagnostic HVT for seizure classification and polysomnographies can be carried out safely in the patients' home and poses no security risks for staff. HVT can be effectively integrated into an existing tertiary care service as a routine home or community-based procedure. We hope to encourage other clinical neurophysiology departments and epilepsy centres to take advantage of our experience and consider adopting and implementing HVT, with the aim of a nationwide coverage. Copyright © 2014 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  2. Evaluation of a miniature magnetostrictive actuator using Galfenol under tensile stress

    International Nuclear Information System (INIS)

    Ueno, Toshiyuki; Miura, Hidemitsu; Yamada, Sotoshi

    2011-01-01

    We are, at present, developing miniature actuators using an iron-gallium alloy (Galfenol). Galfenol is an iron-based magnetostrictive material with magnetostriction exceeding 200 ppm, Young's modulus of 70 GPa and a high relative permeability (>100). The advantages of an actuator using this material are capability of miniaturization, stability against external force, low voltage driving and high power. In this study, a miniature vibrator using an E core of Galfenol under tensile stress up to 20 MPa was investigated. The vibrator did not fracture and maintained the magnetostriction even under a high tensile stress. In addition, the resonance frequency, unchanged under the tensile stress, was lower than the cutoff frequency, hence the vibrator can be driven with a low voltage even in resonance driving. The temperature rise in resonance driving was low and creep was not observed in resonance driving under tensile stress. The vibrator will be applicable in flat panel or bone conductive speakers.

  3. Evaluation of a miniature magnetostrictive actuator using Galfenol under tensile stress

    Science.gov (United States)

    Ueno, Toshiyuki; Miura, Hidemitsu; Yamada, Sotoshi

    2011-02-01

    We are, at present, developing miniature actuators using an iron-gallium alloy (Galfenol). Galfenol is an iron-based magnetostrictive material with magnetostriction exceeding 200 ppm, Young's modulus of 70 GPa and a high relative permeability (>100). The advantages of an actuator using this material are capability of miniaturization, stability against external force, low voltage driving and high power. In this study, a miniature vibrator using an E core of Galfenol under tensile stress up to 20 MPa was investigated. The vibrator did not fracture and maintained the magnetostriction even under a high tensile stress. In addition, the resonance frequency, unchanged under the tensile stress, was lower than the cutoff frequency, hence the vibrator can be driven with a low voltage even in resonance driving. The temperature rise in resonance driving was low and creep was not observed in resonance driving under tensile stress. The vibrator will be applicable in flat panel or bone conductive speakers.

  4. Nanoparticle separation with a miniaturized asymmetrical flow field-flow fractionation cartridge

    Science.gov (United States)

    Müller, David; Cattaneo, Stefano; Meier, Florian; Welz, Roland; deMello, Andrew

    2015-07-01

    Asymmetrical Flow Field-Flow Fractionation (AF4) is a separation technique applicable to particles over a wide size range. Despite the many advantages of AF4, its adoption in routine particle analysis is somewhat limited by the large footprint of currently available separation cartridges, extended analysis times and significant solvent consumption. To address these issues, we describe the fabrication and characterization of miniaturized AF4 cartridges. Key features of the scale-down platform include simplified cartridge and reagent handling, reduced analysis costs and higher throughput capacities. The separation performance of the miniaturized cartridge is assessed using certified gold and silver nanoparticle standards. Analysis of gold nanoparticle populations indicates shorter analysis times and increased sensitivity compared to conventional AF4 separation schemes. Moreover, nanoparticulate titanium dioxide populations exhibiting broad size distributions are analyzed in a rapid and efficient manner. Finally, the repeatability and reproducibility of the miniaturized platform are investigated with respect to analysis time and separation efficiency.

  5. Miniature scientific-grade magnetic sensors for CubeSats

    Science.gov (United States)

    Pronenko, Vira; Belyayev, Serhiy

    2016-07-01

    Micro- and nanosatellites have become more attractive due to their low development and launch cost. A class of nanosatellites defined by the CubeSat standard allows standardizing CubeSat preparation and launch, thus making the projects more affordable. Because of the complexity of sensors miniaturization to install them onboard CubeSat, the majority of CubeSat launches are aimed the technology demonstration or education missions. The scientific success of CubeSat mission depends on the sensors quality. In spite that the sensitivity of the magnetic sensors strongly depends on their size, the recent development in this branch allows us to propose tiny but sensitive both AC and DC magnetometers. The goal of the present report is to introduce the new design of miniature three-component sensors for measurement of vector magnetic fields - for quasi-stationary and slowly fluctuating - flux-gate magnetometer (FGM) - and for alternative ones - search-coil magnetometer (SCM). In order to create magnetometers with the really highest possible level of parameters, a set of scientific and technological problems, mostly aimed at the sensor construction improvement, was solved. The most important parameter characterizing magnetometer quality is its own magnetic noise level (NL). The analysis of the NL influencing factors is made and the ways to decrease it are discussed in the report. Construction details and technical specifications of miniature but sensitive FGM and SCM for the CubeSat mission are presented. This work is supported by EC Framework 7 funded project 607197.

  6. SCA Waveform Development for Space Telemetry

    Science.gov (United States)

    Mortensen, Dale J.; Kifle, Multi; Hall, C. Steve; Quinn, Todd M.

    2004-01-01

    The NASA Glenn Research Center is investigating and developing suitable reconfigurable radio architectures for future NASA missions. This effort is examining software-based open-architectures for space based transceivers, as well as common hardware platform architectures. The Joint Tactical Radio System's (JTRS) Software Communications Architecture (SCA) is a candidate for the software approach, but may need modifications or adaptations for use in space. An in-house SCA compliant waveform development focuses on increasing understanding of software defined radio architectures and more specifically the JTRS SCA. Space requirements put a premium on size, mass, and power. This waveform development effort is key to evaluating tradeoffs with the SCA for space applications. Existing NASA telemetry links, as well as Space Exploration Initiative scenarios, are the basis for defining the waveform requirements. Modeling and simulations are being developed to determine signal processing requirements associated with a waveform and a mission-specific computational burden. Implementation of the waveform on a laboratory software defined radio platform is proceeding in an iterative fashion. Parallel top-down and bottom-up design approaches are employed.

  7. Miniaturized chromatographic radiochemical procedure for 131I - MIBG

    International Nuclear Information System (INIS)

    Barboza, M.F. de; Pereira, N.S. de; Colturato, M.T.; Silva, C.P.G. da.

    1989-12-01

    Different solvents were used in paper chromatographic methods to obtain the best system in routine radiochemical control for 131 I-MIBG produced at IPEN-CNEN/SP. The dates were compared with those obtained with eletrophoresis method in buffer acetate, pH=4.5, 350V, during 40 minutes. The stability of the labeled compound store under 4 0 C was studied during 15 days. Miniaturized chromatographic procedures were established using Whatman 3MM (8x1cm) and n-butanol-:acetic acid: water (S:2:1) as a solvent. the Rf values were: 0.3 (I - ) and 1.0 (MIBG). The radiochemical purity was 99.3 and 99.2% (first day) obtained with eletrophoresis and miniaturized chromatographic procedures, respectively and, 84.7% after 15 days of its preparation. It is a rapid, practical and reproductive method. (author) [pt

  8. Miniaturized and reconfigurable notch antenna based on a BST ferroelectric thin film

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Hung Viet [Institut d' Electronique et de Télécommunications de Rennes (IETR), IUT Saint-Brieuc, Université de Rennes 1, 22004 Saint-Brieuc (France); CEA-LETI, Minatec, 17 avenue des Martyrs, 38054 Grenoble Cedex 9 (France); Benzerga, Ratiba, E-mail: ratiba.benzerga@univ-rennes1.fr [Institut d' Electronique et de Télécommunications de Rennes (IETR), IUT Saint-Brieuc, Université de Rennes 1, 22004 Saint-Brieuc (France); Borderon, Caroline [IETR, Université de Nantes, 2 rue de la Houssinière, 44322 Nantes (France); Delaveaud, Christophe [CEA-LETI, Minatec, 17 avenue des Martyrs, 38054 Grenoble Cedex 9 (France); Sharaiha, Ala [Institut d' Electronique et de Télécommunications de Rennes (IETR), IUT Saint-Brieuc, Université de Rennes 1, 22004 Saint-Brieuc (France); Renoud, Raphael [IETR, Université de Nantes, 2 rue de la Houssinière, 44322 Nantes (France); Paven, Claire Le [Institut d' Electronique et de Télécommunications de Rennes (IETR), IUT Saint-Brieuc, Université de Rennes 1, 22004 Saint-Brieuc (France); Pavy, Sabrina; Nadaud, Kevin; Gundel, Hartmut W. [IETR, Université de Nantes, 2 rue de la Houssinière, 44322 Nantes (France)

    2015-07-15

    Highlights: • A miniature and agile antenna based on a BST MIM capacitor is simulated and made. • Mn{sup 2+} doped BST thin films are synthesized by chemical deposition and spin coating. • Permittivity and losses of the BST thin film are respectively 225 and 0.02 at 1 GHz. • A miniaturization rate of 70% is obtained with a MIM capacitance of 3.7 pF. • A frequency tunability of 14.5% and a tunability performance of 0.04 are measured. - Abstract: This work deals with the design, realization and characterization of a miniature and frequency agile antenna based on a ferroelectric Ba{sub 0,80}Sr{sub 0,20}TiO{sub 3} thin film. The notch antenna is loaded with a variable metal/insulator/metal (MIM) capacitor and is achieved by a monolithic method. The MIM capacitance is 3.7 pF, which results in a resonant frequency of 670 MHz compared to 2.25 GHz for the unloaded simulated antenna; the resulting miniaturization rate is 70%. The characterization of the antenna prototype shows a frequency tunable rate of 14.5% under an electric field of 375 kV/cm, with a tunability performance η = 0.04.

  9. Miniature X-ray Tube for Electric Brachytherapy using Carbon Nanotube Field Emitter

    International Nuclear Information System (INIS)

    Heo, Sung Hwan; Kim, Hyun Jin; Ha, Jun Mok; Cho, Sung Oh

    2011-01-01

    An electric brachytherapy using a miniature x-ray tube has a major advantage to reduce the x-ray exposure of human body during the cancer radiation therapy by optimal positioning of x-ray radiation source and treatment objectives. In the view of a smaller electronic x-ray source, the CNT field emitter based xray tube can be more minimized than thermionic filament emitter based one because of a simple power supplier connection of cold field emission in diode type as well as a higher electron emission brightness of CNT. This abstract is for introducing the design of a prototype CNT field emitter based miniature x-ray tube. We have vacuum sealed CNT miniature x-ray tube with 7∼10 mm diameter, and characteristics of electron emission and x-ray transportation using MCNP5 code are surveyed

  10. Factors that influence the acceptance of telemetry by emergency medical technicians in ambulances: an application of the extended technology acceptance model.

    Science.gov (United States)

    Hwang, Ji Young; Kim, Ki Young; Lee, Kang Hyun

    2014-12-01

    The aim of the study was to verify the effects of patient factors perceived by emergency medical technicians (EMTs) as well as their social and organizational factors on prehospital telemetry use intention based on the technology use intention and elaboration likelihood models. This is a retrospective empirical study. Questionnaires were developed on the basis of clinical factors of 72,907 patients assessed by prehospital telemetry from January 1, 2009 to April 30, 2012 by reviewing their prehospital medical care records and in-hospital medical records. Questionnaires regarding the social and organizational factors of EMTs were created on the basis of a literature review. To verify which factors affect the utilization of telemetry, we developed a partial least-squares route model on the basis of each characteristic. In total, 136 EMTs who had experience in using prehospital telemetry were surveyed from April 1 to April 7, 2013. Reliability, validity, hypotheses, and the model goodness of fit of the study tools were tested. The clinical factors of the patients (path coefficient=-0.12; t=2.38), subjective norm (path coefficient=0.18; t=2.63), and job fit (path coefficient=0.45; t=5.29) positively affected the perceived usefulness (p<0.010). Meanwhile, the clinical factors of the patients (path coefficients=-0.19; t=4.46), subjective norm (path coefficient=0.08; t=1.97), loyalty incentives (path coefficient=-0.17; t=3.83), job fit (path coefficient=-0.32; t=7.06), organizational facilitations (path coefficient=0.08; t=1.99), and technical factors (i.e., usefulness and ease of use) positively affected attitudes (path coefficient=0.10, 0.58; t=2.62, 5.81; p<0.010). Attitudes and perceived usefulness significantly positively affected use intention. Factors that influence the use of telemetry by EMTs in ambulances included patients' clinical factors, as well as complex organizational and environmental factors surrounding the EMTs' occupational environments. This suggests

  11. A miniaturized plastic dilution refrigerator

    International Nuclear Information System (INIS)

    Bindilatti, V.; Oliveira, N.F.Jr.; Martin, R.V.; Frossati, G.

    1996-01-01

    We have built and tested a miniaturized dilution refrigerator, completely contained (still, heat exchanger and mixing chamber) inside a plastic (PVC) tube of 10 mm diameter and 170 mm length. With a 25 cm 2 CuNi heat exchanger, it reached temperatures below 50 mK, for circulation rates below 70 μmol/s. The cooling power at 100 mK and 63 μmol/s was 45 μW. The experimental space could accommodate samples up to 6 mm in diameter. (author)

  12. A molecular diagnostic test for persistent Müllerian duct syndrome in miniature schnauzer dogs.

    Science.gov (United States)

    Pujar, S; Meyers-Wallen, V N

    2009-01-01

    In persistent Müllerian duct syndrome (PMDS), Müllerian ducts fail to regress in males during sexual differentiation. In the canine miniature schnauzer model, PMDS is caused by a C to T transition in exon 3 of the Müllerian inhibiting substance type II receptor (MISRII), which introduces a DdeI restriction site. Here we report a molecular diagnostic test for PMDS in the miniature schnauzer to identify affected dogs and carriers. As our test results suggest that the mutation is identical by descent in affected dogs of this breed, the test could be used to eliminate this mutation from the miniature schnauzer breed worldwide.

  13. Maxillary bone epithelial cyst in an adult miniature schnauzer.

    Science.gov (United States)

    Lin, Chung-Tien; Tasi, Wen-Chih; Hu, Chun-Kun; Lin, Nien-Ting; Huang, Pei-Yun; Yeh, Lih-Seng

    2008-09-01

    Maxillary bone epithelial cyst is rare in dogs. A 5-year-old, spayed female miniature schnauzer developed a swelling below the nasal canthus of left eye. Plain radiograph demonstrated a 1.5 cm diameter of radiolucent lesion on the maxillary bone anteroventral to the eye, and contrast dacryocystorhinography confirmed an obstructed nasolarcrimal duct. The swelling showed poor response to antibiotic treatment but responded well to oral prednisolone. Exploratory surgery revealed a cyst-like structure filled with brown serous fluid. Histopathological examination of the removed cyst revealed a double cuboidal epithelial cyst. The dog recovered rapidly after surgery, and the swelling had not recurred for a 36-month follow-up. It is the first case of periorbital bone epithelial cyst reported in an adult miniature schnauzer.

  14. Miniaturizing EM Sample Preparation: Opportunities, Challenges, and "Visual Proteomics".

    Science.gov (United States)

    Arnold, Stefan A; Müller, Shirley A; Schmidli, Claudio; Syntychaki, Anastasia; Rima, Luca; Chami, Mohamed; Stahlberg, Henning; Goldie, Kenneth N; Braun, Thomas

    2018-03-01

    This review compares and discusses conventional versus miniaturized specimen preparation methods for transmission electron microscopy (TEM). The progress brought by direct electron detector cameras, software developments and automation have transformed transmission cryo-electron microscopy (cryo-EM) and made it an invaluable high-resolution structural analysis tool. In contrast, EM specimen preparation has seen very little progress in the last decades and is now one of the main bottlenecks in cryo-EM. Here, we discuss the challenges faced by specimen preparation for single particle EM, highlight current developments, and show the opportunities resulting from the advanced miniaturized and microfluidic sample grid preparation methods described, such as visual proteomics and time-resolved cryo-EM studies. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. The Motus Wildlife Tracking System: a collaborative research network to enhance the understanding of wildlife movement

    Directory of Open Access Journals (Sweden)

    Philip D. Taylor

    2017-06-01

    Full Text Available We describe a new collaborative network, the Motus Wildlife Tracking System (Motus; https://motus.org, which is an international network of researchers using coordinated automated radio-telemetry arrays to study movements of small flying organisms including birds, bats, and insects, at local, regional, and hemispheric scales. Radio-telemetry has been a cornerstone of tracking studies for over 50 years, and because of current limitations of geographic positioning systems (GPS and satellite transmitters, has remained the primary means to track movements of small animals with high temporal and spatial precision. Automated receivers, along with recent miniaturization and digital coding of tags, have further improved the utility of radio-telemetry by allowing many individuals to be tracked continuously and simultaneously across broad landscapes. Motus is novel among automated arrays in that collaborators employ a single radio frequency across receiving stations over a broad geographic scale, allowing individuals to be detected at sites maintained by others. Motus also coordinates, disseminates, and archives detections and associated metadata in a central repository. Combined with the ability to track many individuals simultaneously, Motus has expanded the scope and spatial scale of research questions that can be addressed using radio-telemetry from local to regional and even hemispheric scales. Since its inception in 2012, more than 9000 individuals of over 87 species of birds, bats, and insects have been tracked, resulting in more than 250 million detections. This rich and comprehensive dataset includes detections of individuals during all phases of the annual cycle (breeding, migration, and nonbreeding, and at a variety of spatial scales, resulting in novel insights into the movement behavior of small flying animals. The value of the Motus network will grow as spatial coverage of stations and number of partners and collaborators increases. With

  16. Telemetry Standards, RCC Standard 106-17, Chapter 27, RF Network Access Layer

    Science.gov (United States)

    2017-07-01

    to the physical media (i.e., the wireless RF network). On the transmission side, it is responsible for framing IP packets for physical transmission ...resolution bandwidth of 30 kHz. It was measured during the steady power condition during a burst transmission . Telemetry Standards, RCC Standard... power levels available for modulated burst transmission . Table 27-1. Transceiver Phase Noise Mask dBc/Hz Frequency Offset −30 dBc/Hz 10 Hz −60 dBc

  17. Proteinuria and lipoprotein lipase activity in Miniature Schnauzer dogs with and without hypertriglyceridemia.

    Science.gov (United States)

    Furrow, E; Jaeger, J Q; Parker, V J; Hinchcliff, K W; Johnson, S E; Murdoch, S J; de Boer, I H; Sherding, R G; Brunzell, J D

    2016-06-01

    Spontaneous hyperlipidemia in rats causes glomerular disease. Idiopathic hypertriglyceridemia (HTG) is prevalent in Miniature Schnauzers, but its relationship with proteinuria is unknown. Decreased activity of major lipid metabolism enzymes, lipoprotein lipase (LPL) and hepatic lipase (HL), may play a role in the cyclic relationship between hyperlipidemia and proteinuria. These enzymes have also not been previously investigated in Miniature Schnauzers. The aims of this study were to determine the relationship between HTG and proteinuria in Miniature Schnauzers and to measure LPL and HL activities in a subset of dogs. Fifty-seven Miniature Schnauzers were recruited (34 with and 23 without HTG). Fasting serum triglyceride concentrations and urine protein-to-creatinine ratios (UPC) were measured in all dogs, and LPL and HL activities were determined in 17 dogs (8 with and 9 without HTG). There was a strong positive correlation between triglyceride concentration and UPC (r = 0.77-0.83, P Schnauzers and could be due to lipid-induced glomerular injury. Reduced LPL activity may contribute to the severity of HTG, but further assay validation is required. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Miniature Reaction Wheel for Small Satellite Control, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of this project is to design, develop, demonstrate, and deliver a miniature, high torque, low-vibration reaction wheel for use on small satellites....

  19. Telemetry experiments with a hibernating black bear

    Science.gov (United States)

    Craighead, J. J.; Varney, J. R.; Sumner, J. S.; Craighead, F. C., Jr.

    1972-01-01

    The objectives of this research were to develop and test telemetry equipment suitable for monitoring physiological parameters and activity of a hibernating bear in its den, to monitor this data and other environmental information with the Nimbus 3 IRLS data collection system, and to refine immobilizing, handling, and other techniques required in future work with wild bears under natural conditions. A temperature-telemetering transmitter was implanted in the abdominal cavity of a captive black bear and body temperature data was recorded continuously during a 3 month hibernation period. Body temperatures ranging between 37.5 and 31.8 C were observed. Body temperature and overall activity were influenced by disturbances and ambient den temperature. Nychthemeral temperature changes were not noticable. A load cell weight recording device was tested for determining weight loss during hibernation. Monitoring of data by satellite was not attempted. The implanted transmitter was removed and the bear was released with a radiolocation collar at the conclusion of the experiment.

  20. The MIT miniaturized disk bend test

    International Nuclear Information System (INIS)

    Harling, O.K.; Lee, M.; Sohn, D.S.; Kohse, G.; Lau, C.W.

    1983-01-01

    A miniaturized disk bend test (MDBT) using transmission electron microscopy specimens for the determination of various mechanical properties is being developed at MIT. Recent progress in obtaining strengths and ductilities of highly irradiated metal alloys is reviewed. Possibilities exist for applying the MDBT approach to the determination of other mechanical properties. Progress in fatigue testing and in determination of the ductile-to-brittle transition temperature is reviewed briefly

  1. Miniature magnetic fluid seal working in liquid environments

    Science.gov (United States)

    Mitamura, Yoshinori; Durst, Christopher A.

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump.

  2. An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring.

    Science.gov (United States)

    Javan-Khoskholgh, Amir; Abukhalaf, Zaid; Ji Li; Miller, Larry S; Kiani, Mehdi; Farajidavar, Aydin

    2016-08-01

    We present a passive data telemetry system for real-time monitoring of gastric electrical activity of a living subject. The system is composed of three subsystems: an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU). Data communication between the IU and WU is based on a radio-frequency identification (RFID) link operating at 13.56 MHz. Since wireless power transmission and reverse data telemetry system share the same inductive interface, a load shift keying (LSK)-based differential pulse position (DPP) coding data communication with only 6.25% duty cycle is developed to guarantee consistent wireless downlink power transmission and uplink high data transfer rate, simultaneously. The clock and data are encoded into one signal by an MSP430 microcontroller (MCU) at the IU side. This signal is sent to the WU through the inductive link, where decoded by an MSP432 MCU. Finally, the retrieved data at the WU are transmitted to the SU connected to a PC via a 2.4 GHz transceiver for real-time display and analysis. The results of the measurements on the implemented test bench, demonstrate IU-WU 125 kb/s and WU-SU 2 Mb/s data transmission rate with no observed mismatch, while the data stream was randomly generated, and matching between the transmitted data by the IU and received by the SU verified by a custom-made automated software.

  3. National Space Transportation System telemetry distribution and processing, NASA-JFK Space Center/Cape Canaveral

    Science.gov (United States)

    Jenkins, George

    1986-01-01

    Prelaunch, launch, mission, and landing distribution of RF and hardline uplink/downlink information between Space Shuttle Orbiter/cargo elements, tracking antennas, and control centers at JSC, KSC, MSFC, GSFC, ESMC/RCC, and Sunnyvale are presented as functional block diagrams. Typical mismatch problems encountered during spacecraft-to-project control center telemetry transmissions are listed along with new items for future support enhancement.

  4. Pinching evidences in a miniature plasma focus with fast pseudospark switch

    International Nuclear Information System (INIS)

    Hassan, S M; Zhang, T; Patran, A; Rawat, R S; Springham, S V; Tan, T L; Wong, D; Wang, W; Lee, S; Gribkov, V A; Mohanty, S R; Lee, P

    2006-01-01

    We report the observations of pinching in a miniature plasma focus (PF) (58-160 J) operated in repetitive mode using fast pseudospark switch (PSS). The size of the device, which includes the capacitor bank, PSS and the focus chamber, is of the order of 22 cm x 22 cm x 38 cm. Several diagnostic tools, the gated imager, streak camera, current and voltage probe, are employed simultaneously to confirm the occurrence of pinching in this fast miniature PF device. The device is optimized for operation in neon and hydrogen as the working gas. The best focus formation was obtained at pressures between 0.5 to 8.0 mbar for neon and between 7.0 to 15.0 mbar for hydrogen. When the system was operated at 100 J with hydrogen as the filling gas, the typical dip in the current derivative signal and the typical peak in the voltage signal associated with pinch compression, are observed to be most intense indicating efficient pinching in the miniature PF device

  5. Current applications of miniaturized chromatographic and electrophoretic techniques in drug analysis.

    Science.gov (United States)

    Aturki, Zeineb; Rocco, Anna; Rocchi, Silvia; Fanali, Salvatore

    2014-12-01

    In the last decade, miniaturized separation techniques have become greatly popular in pharmaceutical analysis. Miniaturized separation methods are increasingly utilized in all processes of drug discovery as well as quality control of pharmaceutical preparation. The great advantages presented by the analytical miniaturized techniques, including high separation efficiency and resolution, rapid analysis and minimal consumption of reagents and samples, make them an attractive alternative to the conventional chromatographic methods for drug analysis. The purpose of this review is to give a general overview of the applicability of capillary electrophoresis (CE), capillary electrochromatography (CEC) and micro/capillary/nano-liquid chromatography (micro-LC/CLC/nano-LC) for the analysis of pharmaceutical formulations, active pharmaceutical ingredients (API), drug impurity testing, chiral drug separation, determination of drugs and metabolites in biological fluids. The results concerning the use of CEC, micro-LC, CLC, and nano-LC in the period 2009-2013, while for CE, those from 2012 up to the review draft are here summarized and some specific examples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. A Miniature Data Repository on a Raspberry Pi

    NARCIS (Netherlands)

    Samourkasidis, Argyrios; Athanasiadis, Ioannis N.

    2017-01-01

    This work demonstrates a low-cost, miniature data repository proof-of-concept. Such a system needs to be resilient to power and network failures, and expose adequate processing power for persistent, long-term storage. Additional services are required for interoperable data sharing and visualization.

  7. Lightweight, Miniature Inertial Measurement System

    Science.gov (United States)

    Tang, Liang; Crassidis, Agamemnon

    2012-01-01

    A miniature, lighter-weight, and highly accurate inertial navigation system (INS) is coupled with GPS receivers to provide stable and highly accurate positioning, attitude, and inertial measurements while being subjected to highly dynamic maneuvers. In contrast to conventional methods that use extensive, groundbased, real-time tracking and control units that are expensive, large, and require excessive amounts of power to operate, this method focuses on the development of an estimator that makes use of a low-cost, miniature accelerometer array fused with traditional measurement systems and GPS. Through the use of a position tracking estimation algorithm, onboard accelerometers are numerically integrated and transformed using attitude information to obtain an estimate of position in the inertial frame. Position and velocity estimates are subject to drift due to accelerometer sensor bias and high vibration over time, and so require the integration with GPS information using a Kalman filter to provide highly accurate and reliable inertial tracking estimations. The method implemented here uses the local gravitational field vector. Upon determining the location of the local gravitational field vector relative to two consecutive sensors, the orientation of the device may then be estimated, and the attitude determined. Improved attitude estimates further enhance the inertial position estimates. The device can be powered either by batteries, or by the power source onboard its target platforms. A DB9 port provides the I/O to external systems, and the device is designed to be mounted in a waterproof case for all-weather conditions.

  8. Seasonal and diel effects on the activity of northern pike studied by high-resolution positional telemetry

    DEFF Research Database (Denmark)

    Baktoft, Henrik; Aarestrup, Kim; Berg, Søren

    2012-01-01

    , a detailed understanding of the behaviour of this species during winter is important. We continuously monitored the activity of adult northern pike (Esox lucius) in a small temperate lake from late summer to winter for two consecutive years using an automatic acoustic positional telemetry system. Four...

  9. Flight experience with lightweight, low-power miniaturized instrumentation systems

    Science.gov (United States)

    Hamory, Philip J.; Murray, James E.

    1992-01-01

    Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this paper is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. The paper will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. The paper also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. Finally, future plans for these systems will be discussed.

  10. Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft

    Science.gov (United States)

    Rizvi, Farheen

    2013-01-01

    A report describes a model that estimates the orientation of the backup reaction wheel using the reaction wheel spin rates telemetry from a spacecraft. Attitude control via the reaction wheel assembly (RWA) onboard a spacecraft uses three reaction wheels (one wheel per axis) and a backup to accommodate any wheel degradation throughout the course of the mission. The spacecraft dynamics prediction depends upon the correct knowledge of the reaction wheel orientations. Thus, it is vital to determine the actual orientation of the reaction wheels such that the correct spacecraft dynamics can be predicted. The conservation of angular momentum is used to estimate the orientation of the backup reaction wheel from the prime and backup reaction wheel spin rates data. The method is applied in estimating the orientation of the backup wheel onboard the Cassini spacecraft. The flight telemetry from the March 2011 prime and backup RWA swap activity on Cassini is used to obtain the best estimate for the backup reaction wheel orientation.

  11. Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized

    Science.gov (United States)

    Adell, Philippe C.; Mojarradi, Mohammad; DelCastillo, Linda Y.; Vo, Tuan A.

    2011-01-01

    A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.

  12. Acoustic Telemetry Studies of Juvenile Chinook Salmon Survival at the Lower Columbia Projects in 2006

    Energy Technology Data Exchange (ETDEWEB)

    Ploskey, Gene R.; Weiland, Mark A.; Hughes, James S.; Zimmerman, Shon A.; Durham, Robin E.; Fischer, Eric S.; Kim, Jina; Townsend, Richard L.; Skalski, John R.; McComas, Roy L.

    2008-02-01

    The Portland District of the U.S. Army Corps of Engineers contracted with the Pacific Northwest National Laboratory (PNNL) to conduct three studies using acoustic telemetry to estimate detection probabilities and survival of juvenile Chinook salmon at three hydropower projects on the lower Columbia River. The primary goals were to estimate detection and survival probabilities based on sampling with JSATS equipment, assess the feasibility of using JSATS for survival studies, and estimate sample sizes needed to obtain a desired level of precision in future studies. The 2006 JSATS arrays usually performed as well or better than radio telemetry arrays in the JDA and TDA tailwaters, and underperformed radio arrays in the BON tailwater, particularly in spring. Most of the probabilities of detection on at least one of all arrays in a tailwater exceeded 80% for each method, which was sufficient to provide confidence in survival estimates. The probability of detection on one of three arrays includes survival and detection probabilities because fish may die or pass all three arrays undetected but alive.

  13. Miniature rainbow schlieren deflectometry system for quantitative measurements in microjets and flames

    International Nuclear Information System (INIS)

    Satti, Rajani P.; Kolhe, Pankaj S.; Olcmen, Semih; Agrawal, Ajay K.

    2007-01-01

    Recent interest in small-scale flow devices has created the need for miniature instruments capable of measuring scalar flow properties with high spatial resolution. We present a miniature rainbow schlieren deflectometry system to nonintrusively obtain quantitative species concentration and temperature data across the whole field. The optical layout of the miniature system is similar to that of a macroscale system, although the field of view is smaller by an order of magnitude. Employing achromatic lenses and a CCD array together with a camera lens and extension tubes, we achieved spatial resolution down to 4 μm. Quantitative measurements required a careful evaluation of the optical components. The capability of the system is demonstrated by obtaining concentration measurements in a helium microjet (diameter, d=650 μm) and temperature and concentration measurements in a hydrogen jet diffusion flame from a microinjector(d=50 μm). Further, the flow field of underexpanded nitrogen jets is visualized to reveal details of the shock structures existing downstream of the jet exit

  14. An integrated one-chip-sensor system for microRNA quantitative analysis based on digital droplet polymerase chain reaction

    Science.gov (United States)

    Tsukuda, Masahiko; Wiederkehr, Rodrigo Sergio; Cai, Qing; Majeed, Bivragh; Fiorini, Paolo; Stakenborg, Tim; Matsuno, Toshinobu

    2016-04-01

    A silicon microfluidic chip was developed for microRNA (miRNA) quantitative analysis. It performs sequentially reverse transcription and polymerase chain reaction in a digital droplet format. Individual processes take place on different cavities, and reagent and sample mixing is carried out on a chip, prior to entering each compartment. The droplets are generated on a T-junction channel before the polymerase chain reaction step. Also, a miniaturized fluorescence detector was developed, based on an optical pick-up head of digital versatile disc (DVD) and a micro-photomultiplier tube. The chip integrated in the detection system was tested using synthetic miRNA with known concentrations, ranging from 300 to 3,000 templates/µL. Results proved the functionality of the system.

  15. Ambiguous genitalia in a fertile, unilaterally cryptorchid male miniature schnauzer dog.

    Science.gov (United States)

    Breshears, M A; Peters, J L

    2011-09-01

    A 7-year-old male miniature schnauzer dog with unilateral cryptorchidism was presented for elective orchiectomy. Surgery to remove the cryptorchid testis revealed a fully formed uterus with horns attached to both testis and the body and cervix terminating at the prostate gland. The gross and microscopic diagnosis for the genital tract was persistent Müllerian duct syndrome with unilateral cryptorchidism. Additional associated lesions included cystic endometrial hyperplasia and a solitary, intratubular seminoma within the undescended testis. Persistent Müllerian duct syndrome is rare among domestic animals but is more common in miniature schnauzer dogs because of inheritance as an autosomal recessive trait.

  16. Hereditary esophageal dysfunction in the Miniature Schnauzer dog.

    Science.gov (United States)

    Cox, V S; Wallace, L J; Anderson, V E; Rushmer, R A

    1980-03-01

    Miniature Schnauzers maintained in a colony for 9 years were used to study the inheritance of esophageal dysfunction (canine achalasia, megaesophagus). All dogs were evaluated radiographically, using a barium swallow contrast technique which clearly distinguished normal and affected pups. At 4 to 6 months of age, all affected dogs had recovered clinically except one, and radiographic evidence of dysfunction was markedly diminished. None of the affected dogs required a special feeding regimen. Analysis of breeding pairs revealed a ratio of 9 affected/11 normal dogs when an affected male was mated with a normal female, and a 13/3 ratio was observed when two affected dogs were mated. These ratios were compatible with a simple autosomal dominant or a 60% penetrance autosomal-recessive mode of inheritance. Outbreeding to an affected Miniature Schnauzer/Poodle crossbred dog resulted in only two of 30 affected pups, indicating a polygenic mode of inheritance in outbred populations.

  17. Adventitious shoot regeneration from leaf explants of miniature paprika

    African Journals Online (AJOL)

    STORAGESEVER

    2010-05-10

    May 10, 2010 ... products, Capsicum spp. shows high levels of cross pollination ... Composition of a nutrient solution used for the culture of miniature paprika in the greenhouse. ... Yellow' were obtained from Seminis Korea Inc. Seeds were.

  18. Miniature linear cooler development

    International Nuclear Information System (INIS)

    Pruitt, G.R.

    1993-01-01

    An overview is presented of the status of a family of miniature linear coolers currently under development by Hughes Aircraft Co. for use in hand held, volume limited or power limited infrared applications. These coolers, representing the latest additions to the Hughes family of TOP trademark [twin-opposed piston] linear coolers, have been fabricated and tested in three different configurations. Each configuration is designed to utilize a common compressor assembly resulting in reduced manufacturing costs. The baseline compressor has been integrated with two different expander configurations and has been operated with two different levels of input power. These various configuration combinations offer a wide range of performance and interface characteristics which may be tailored to applications requiring limited power and size without significantly compromising cooler capacity or cooldown characteristics. Key cooler characteristics and test data are summarized for three combinations of cooler configurations which are representative of the versatility of this linear cooler design. Configurations reviewed include the shortened coldfinger [1.50 to 1.75 inches long], limited input power [less than 17 Watts] for low power availability applications; the shortened coldfinger with higher input power for lightweight, higher performance applications; and coldfingers compatible with DoD 0.4 Watt Common Module coolers for wider range retrofit capability. Typical weight of these miniature linear coolers is less than 500 grams for the compressor, expander and interconnecting transfer line. Cooling capacity at 80K at room ambient conditions ranges from 400 mW to greater than 550 mW. Steady state power requirements for maintaining a heat load of 150 mW at 80K has been shown to be less than 8 Watts. Ongoing reliability growth testing is summarized including a review of the latest test article results

  19. Biometry and clinical characteristics of congenital cataracts and microphthalmia in the Miniature Schnauzer.

    Science.gov (United States)

    Gelatt, K N; Samuelson, D A; Barrie, K P; Das, N D; Wolf, E D; Bauer, J E; Andresen, T L

    1983-07-01

    Forty-two Miniature Schnauzer pups and adults with congenital cataracts and microphthalmia were evaluated by serial ophthalmic examinations, slit lamp biomicroscopic photography, and A-scan ultrasonography. The cataracts were evident when the eyelids opened at 2 weeks, affecting predominantly the lens nucleus and posterior cortex. Lenticonus was evident in 19% of the cataractous lenses. Progression of the cataracts was variable and related to involvement of the equatorial and posterior cortices. Lens-induced uveitis developed in some adult dogs with advanced hypermature cataracts. The globe and lens were smaller than normal in the cataractous eyes, as ascertained by A-scan ultrasonography. Age-matched comparisons of clear lens carrier Miniature Schnauzers and normal Beagles with the cataractous Miniature Schnauzers indicated affected globes and cataractous lenses were reduced 10% to 20% in their anteroposterior lengths. The microphthalmia appeared related to the congenital microphakic cataract.

  20. Long-term blood glucose monitoring with implanted telemetry device in conscious and stress-free cynomolgus monkeys.

    Science.gov (United States)

    Wang, B; Sun, G; Qiao, W; Liu, Y; Qiao, J; Ye, W; Wang, H; Wang, X; Lindquist, R; Wang, Y; Xiao, Y-F

    2017-09-01

    Continuous blood glucose monitoring, especially long-term and remote, in diabetic patients or research is very challenging. Nonhuman primate (NHP) is an excellent model for metabolic research, because NHPs can naturally develop Type 2 diabetes mellitus (T2DM) similarly to humans. This study was to investigate blood glucose changes in conscious, moving-free cynomolgus monkeys (Macaca fascicularis) during circadian, meal, stress and drug exposure. Blood glucose, body temperature and physical activities were continuously and simultaneously recorded by implanted HD-XG telemetry device for up to 10 weeks. Blood glucose circadian changes in normoglycemic monkeys significantly differed from that in diabetic animals. Postprandial glucose increase was more obvious after afternoon feeding. Moving a monkey from its housing cage to monkey chair increased blood glucose by 30% in both normoglycemic and diabetic monkeys. Such increase in blood glucose declined to the pre-procedure level in 30 min in normoglycemic animals and >2 h in diabetic monkeys. Oral gavage procedure alone caused hyperglycemia in both normoglycemic and diabetic monkeys. Intravenous injection with the stress hormones, angiotensin II (2 μg/kg) or norepinephrine (0.4 μg/kg), also increased blood glucose level by 30%. The glucose levels measured by the telemetry system correlated significantly well with glucometer readings during glucose tolerance tests (ivGTT or oGTT), insulin tolerance test (ITT), graded glucose infusion (GGI) and clamp. Our data demonstrate that the real-time telemetry method is reliable for monitoring blood glucose remotely and continuously in conscious, stress-free, and moving-free NHPs with the advantages highly valuable to diabetes research and drug discovery.

  1. Miniaturization of components and systems for space using MEMS-technology

    Science.gov (United States)

    Grönland, Tor-Arne; Rangsten, Pelle; Nese, Martin; Lang, Martin

    2007-06-01

    Development of MEMS-based (micro electro mechanical system) components and subsystems for space applications has been pursued by various research groups and organizations around the world for at least two decades. The main driver for developing MEMS-based components for space is the miniaturization that can be achieved. Miniaturization can not only save orders of magnitude in mass and volume of individual components, but it can also allow increased redundancy, and enable novel spacecraft designs and mission scenarios. However, the commercial breakthrough of MEMS has not occurred within the space business as it has within other branches such as the IT/telecom or automotive industries, or as it has in biotech or life science applications. A main explanation to this is the highly conservative attitude to new technology within the space community. This conservatism is in many senses motivated by a very low risk acceptance in the few and costly space projects that actually ends with a space flight. To overcome this threshold there is a strong need for flight opportunities where reasonable risks can be accepted. Currently there are a few flight opportunities allowing extensive use of new technology in space, but one of the exceptions is the PRISMA program. PRISMA is an international (Sweden, Germany, France, Denmark, Norway, Greece) technology demonstration program with focus on rendezvous and formation flying. It is a two satellite LEO mission with a launch scheduled for the first half of 2009. On PRISMA, a number of novel technologies e.g. RF metrology sensor for Darwin, autonomous formation flying based on GPS and vision-based sensors, ADN-based "green propulsion" will be demonstrated in space for the first time. One of the satellites will also have a miniaturized propulsion system onboard based on MEMS-technology. This novel propulsion system includes two microthruster modules, each including four thrusters with micro- to milli-Newton thrust capability. The novelty

  2. Miniature shock tube for laser driven shocks.

    Science.gov (United States)

    Busquet, Michel; Barroso, Patrice; Melse, Thierry; Bauduin, Daniel

    2010-02-01

    We describe in this paper the design of a miniature shock tube (smaller than 1 cm(3)) that can be placed in a vacuum vessel and allows transverse optical probing and longitudinal backside extreme ultraviolet emission spectroscopy in the 100-500 A range. Typical application is the study of laser launched radiative shocks, in the framework of what is called "laboratory astrophysics."

  3. A Miniaturized Optical Sensor with Integrated Gas Cell

    NARCIS (Netherlands)

    Ayerden, N.P.; Ghaderi, M.; De Graaf, G.; Wolffenbuttel, R.F.

    2015-01-01

    The design, fabrication and characterization of a highly integrated optical gas sensor is presented. The gas cell takes up most of the space in a microspectrometer and is the only component that has so far not been miniaturized. Using the tapered resonator cavity of a linear variable optical filter

  4. Recombinant drugs-on-a-chip: The usage of capillary electrophoresis and trends in miniaturized systems – A review

    Energy Technology Data Exchange (ETDEWEB)

    Morbioli, Giorgio Gianini; Mazzu-Nascimento, Thiago; Aquino, Adriano [Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil); Cervantes, Cesar [Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP (Brazil); Carrilho, Emanuel, E-mail: emanuel@iqsc.usp.br [Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São-carlense, 400, 13566-590 São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil)

    2016-09-07

    We present here a critical review covering conventional analytical tools of recombinant drug analysis and discuss their evolution towards miniaturized systems foreseeing a possible unique recombinant drug-on-a-chip device. Recombinant protein drugs and/or pro-drug analysis require sensitive and reproducible analytical techniques for quality control to ensure safety and efficacy of drugs according to regulatory agencies. The versatility of miniaturized systems combined with their low-cost could become a major trend in recombinant drugs and bioprocess analysis. Miniaturized systems are capable of performing conventional analytical and proteomic tasks, allowing for interfaces with other powerful techniques, such as mass spectrometry. Microdevices can be applied during the different stages of recombinant drug processing, such as gene isolation, DNA amplification, cell culture, protein expression, protein separation, and analysis. In addition, organs-on-chips have appeared as a viable alternative to testing biodrug pharmacokinetics and pharmacodynamics, demonstrating the capabilities of the miniaturized systems. The integration of individual established microfluidic operations and analytical tools in a single device is a challenge to be overcome to achieve a unique recombinant drug-on-a-chip device. - Highlights: • Principal analytical tools for analysis of recombinant drugs are presented. • A critical comparison among different substrates for fabrication of miniaturized systems is made. • Applications of miniaturized systems to produce recombinant drugs are shown. • Future trends of miniaturized systems capable of integrating analytical and proteomic tools in a single device are envisioned.

  5. Recombinant drugs-on-a-chip: The usage of capillary electrophoresis and trends in miniaturized systems – A review

    International Nuclear Information System (INIS)

    Morbioli, Giorgio Gianini; Mazzu-Nascimento, Thiago; Aquino, Adriano; Cervantes, Cesar; Carrilho, Emanuel

    2016-01-01

    We present here a critical review covering conventional analytical tools of recombinant drug analysis and discuss their evolution towards miniaturized systems foreseeing a possible unique recombinant drug-on-a-chip device. Recombinant protein drugs and/or pro-drug analysis require sensitive and reproducible analytical techniques for quality control to ensure safety and efficacy of drugs according to regulatory agencies. The versatility of miniaturized systems combined with their low-cost could become a major trend in recombinant drugs and bioprocess analysis. Miniaturized systems are capable of performing conventional analytical and proteomic tasks, allowing for interfaces with other powerful techniques, such as mass spectrometry. Microdevices can be applied during the different stages of recombinant drug processing, such as gene isolation, DNA amplification, cell culture, protein expression, protein separation, and analysis. In addition, organs-on-chips have appeared as a viable alternative to testing biodrug pharmacokinetics and pharmacodynamics, demonstrating the capabilities of the miniaturized systems. The integration of individual established microfluidic operations and analytical tools in a single device is a challenge to be overcome to achieve a unique recombinant drug-on-a-chip device. - Highlights: • Principal analytical tools for analysis of recombinant drugs are presented. • A critical comparison among different substrates for fabrication of miniaturized systems is made. • Applications of miniaturized systems to produce recombinant drugs are shown. • Future trends of miniaturized systems capable of integrating analytical and proteomic tools in a single device are envisioned.

  6. A miniature turbocompressor system

    Energy Technology Data Exchange (ETDEWEB)

    Zwyssig, C.; Kraehenbuehl, D.; Kolar, J. W. [Swiss Federal Institute of Technology, Power Electronic Systems Laboratory, Zuerich (Switzerland); Weser, H. [High Speed Turbomaschinen GmbH, Wolfsburg (Germany)

    2008-07-01

    The trend in compressors for fuel cells, heat pumps, aerospace and automotive air pressurization, heating, ventilation and air conditioning systems, is towards ultra-compact size and high efficiency. This can be achieved by increasing the rotational speed and employing new electrical drive system technology and materials. This paper presents a miniature, electrically driven turbocompressor system running at a speed of 500,000 rpm. The design includes the thermodynamics, the electric motor, the inverter, the control and the system integration with rotor dynamics and thermal considerations. In the experimental setup, the specified pressure ratio of 1.6 is achieved at a speed of 550,000 rpm, which is slightly higher than the design speed. (author)

  7. Miniature horizontal axis wind turbine system for multipurpose application

    International Nuclear Information System (INIS)

    Xu, F.J.; Yuan, F.G.; Hu, J.Z.; Qiu, Y.P.

    2014-01-01

    A MWT (miniature wind turbine) has received great attention recently for powering WISP (Wireless Intelligent Sensor Platform). In this study, two MHAWTs (miniature horizontal axis wind turbines) with and without gear transmission were designed and fabricated. A physics-based model was proposed and the optimal load resistances of the MHAWTs were predicted. The open circuit voltages, output powers and net efficiencies were measured under various ambient winds and load resistances. The experimental results showed the optimal load resistances matched well with the predicted results; the MHAWT without gear obtained higher output power at the wind speed of 2 m/s to 6 m/s, while the geared MHAWT exhibited better performance at the wind speed higher than 6 m/s. In addition, a DCM (discontinuous conduction mode) buck-boost converter was adopted as an interface circuit to maximize the charging power from MHAWTs to rechargeable batteries, exhibiting maximum efficiencies above 85%. The charging power reached about 8 mW and 36 mW at the wind speeds of 4 m/s and 6 m/s respectively, which indicated that the MHAWTs were capable for sufficient energy harvesting for powering low-power electronics continuously. - Highlights: • Performance of the miniature wind turbines with and without gears was compared. • The physics-based model was established and proved successfully. • The interface circuit with efficiency of more than 85% was designed

  8. Whole-genome sequencing reveals a potential causal mutation for dwarfism in the Miniature Shetland pony.

    Science.gov (United States)

    Metzger, Julia; Gast, Alana Christina; Schrimpf, Rahel; Rau, Janina; Eikelberg, Deborah; Beineke, Andreas; Hellige, Maren; Distl, Ottmar

    2017-04-01

    The Miniature Shetland pony represents a horse breed with an extremely small body size. Clinical examination of a dwarf Miniature Shetland pony revealed a lowered size at the withers, malformed skull and brachygnathia superior. Computed tomography (CT) showed a shortened maxilla and a cleft of the hard and soft palate which protruded into the nasal passage leading to breathing difficulties. Pathological examination confirmed these findings but did not reveal histopathological signs of premature ossification in limbs or cranial sutures. Whole-genome sequencing of this dwarf Miniature Shetland pony and comparative sequence analysis using 26 reference equids from NCBI Sequence Read Archive revealed three probably damaging missense variants which could be exclusively found in the affected foal. Validation of these three missense mutations in 159 control horses from different horse breeds and five donkeys revealed only the aggrecan (ACAN)-associated g.94370258G>C variant as homozygous wild-type in all control samples. The dwarf Miniature Shetland pony had the homozygous mutant genotype C/C of the ACAN:g.94370258G>C variant and the normal parents were heterozygous G/C. An unaffected full sib and 3/5 unaffected half-sibs were heterozygous G/C for the ACAN:g.94370258G>C variant. In summary, we could demonstrate a dwarf phenotype in a miniature pony breed perfectly associated with a missense mutation within the ACAN gene.

  9. Development of real-time software environments for NASA's modern telemetry systems

    Science.gov (United States)

    Horner, Ward; Sabia, Steve

    1989-01-01

    An effort has been made to maintain maximum performance and flexibility for NASA-Goddard's VLSI telemetry system elements through the development of two real-time systems: (1) the Base System Environment, which supports generic system integration and furnishes the basic porting of various manufacturers' cards, and (2) the Modular Environment for Data Systems, which supports application-specific developments and furnishes designers with a set of tested generic library functions that can be employed to speed up the development of such application-specific real-time codes. The performance goals and design rationale for these two systems are discussed.

  10. Two miniature electronic dosemeters Yperwatch - Gamcard

    International Nuclear Information System (INIS)

    Clavel, B.; Jaillon, J.

    1993-01-01

    Yperwatch and Gamcard were miniature electronic gamma personal dose and dose rate monitors. The Yperwatch is mounted in a wristwatch and the Gamcard in a case of the size of a standard credit card. The technology provides users with all the performance of a standard professional electronic dosemeter (integrated dose, dose rate, audible alarms, time in use). Yperwatch and Gamcard are based on well-proven electronic dosimetry technology, but with a greater ease of use. (author)

  11. A miniature Hopkinson experiment device based on multistage reluctance coil electromagnetic launch

    Science.gov (United States)

    Huang, Wenkai; Huan, Shi; Xiao, Ying

    2017-09-01

    A set of seven-stage reluctance miniaturized Hopkinson bar electromagnetic launcher has been developed in this paper. With the characteristics of high precision, small size, and little noise pollution, the device complies with the requirements of miniaturized Hopkinson bar for high strain rate. The launcher is a seven-stage accelerating device up to 65.5 m/s. A high performance microcontroller is used to control accurately the discharge of capacitor sets, by means of which the outlet velocity of the projectile can be controlled within a certain velocity range.

  12. A miniature Hopkinson experiment device based on multistage reluctance coil electromagnetic launch.

    Science.gov (United States)

    Huang, Wenkai; Huan, Shi; Xiao, Ying

    2017-09-01

    A set of seven-stage reluctance miniaturized Hopkinson bar electromagnetic launcher has been developed in this paper. With the characteristics of high precision, small size, and little noise pollution, the device complies with the requirements of miniaturized Hopkinson bar for high strain rate. The launcher is a seven-stage accelerating device up to 65.5 m/s. A high performance microcontroller is used to control accurately the discharge of capacitor sets, by means of which the outlet velocity of the projectile can be controlled within a certain velocity range.

  13. Immobilization of trypsin on miniature incandescent bulbs for infrared-assisted proteolysis

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Huimin; Bao, Huimin; Zhang, Luyan; Chen, Gang, E-mail: gangchen@fudan.edu.cn

    2014-10-03

    Highlights: • Trypsin was immobilized on miniature incandescent bulbs via chitosan coating. • The bulbs acted as enzymatic reactors and the generators of infrared radiation. • The bulb bioreactors were successfully employed in infrared-assisted proteolysis. • The proteolysis could accomplish within 5 min with high sequence coverages. - Abstract: A novel efficient proteolysis approach was developed based on trypsin-immobilized miniature incandescent bulbs and infrared (IR) radiation. Trypsin was covalently immobilized in the chitosan coating on the outer surface of miniature incandescent bulbs with the aid of glutaraldehyde. When an illuminated enzyme-immobilized bulb was immersed in protein solution, the emitted IR radiation could trigger and accelerate heterogeneous protein digestion. The feasibility and performance of the novel proteolysis approach were demonstrated by the digestion of hemoglobin (HEM), cytochrome c (Cyt-c), lysozyme (LYS), and ovalbumin (OVA) and the digestion time was significantly reduced to 5 min. The obtained digests were identified by MALDI-TOF-MS with the sequence coverages of 91%, 77%, 80%, and 52% for HEM, Cyt-c, LYS, and OVA (200 ng μL{sup −1} each), respectively. The suitability of the prepared bulb bioreactors to complex proteins was demonstrated by digesting human serum.

  14. Hodoscope module with miniature photomultipliers

    International Nuclear Information System (INIS)

    Bel'zer, L.I.; Gribushin, A.M.; Zhil'tsov, L.Ya.; Matveeva, E.N.; Philipenko, T.D.; Sinev, N.B.

    1987-01-01

    The experimental Scintillation Magnetic Spectrometer (SMS) installation, whose main element is an extended hodoscope system, is being built for the accelerator of the High Energy Laboratory of the Joint Institute for Nuclear Research. The authors describe the scintillation hodoscope of the SMS installation and present the applicable amplitude and time characteristics of several types of miniature photomultipliers (FEU-58, FEU-60, FEU-114-1, FEU-147-1, and R-1635 (Hamamatsu, Japan)), which were obtained with a 106 Ru radioactive source and standard plastic scintillators of two types, based on oxazoles in polystyrene and in polymethylmethacrylate

  15. Wireless communication with implanted medical devices using the conductive properties of the body.

    Science.gov (United States)

    Ferguson, John E; Redish, A David

    2011-07-01

    Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.

  16. Maintenance energy requirements in miniature colony dogs.

    Science.gov (United States)

    Serisier, S; Weber, M; Feugier, A; Fardet, M-O; Garnier, F; Biourge, V; German, A J

    2013-05-01

    There are numerous reports of maintenance energy requirements (MER) in dogs, but little information is available about energy requirements of miniature dog breeds. In this prospective, observational, cohort study, we aimed to determine MER in dogs from a number of miniature breeds and to determine which factors were associated with it. Forty-two dogs participated in the study. MER was calculated by determining daily energy intake (EI) during a period of 196 days (28-359 days) when body weight did not change significantly (e.g. ±2% in 12 weeks). Estimated median MER was 473 kJ/kg(0.75) /day (285-766 kJ/kg(0.75) /day), that is, median 113 kcal/kg(0.75) /day (68-183 kcal/kg(0.75) /day). In the obese dogs that lost weight, median MER after weight loss was completed was 360 kJ/kg(0.75) /day (285-515 kJ/kg(0.75) /day), that is, 86 kcal/kg(0.75) /day, (68-123 kcal/kg(0.75) /day). Simple linear regression analysis suggested that three breeds (e.g. Chihuahua, p = 0.002; Yorkshire terrier, p = 0.039; dachshund, p = 0.035) had an effect on MER. In addition to breed, simple linear regression revealed that neuter status (p = 0.079) and having previously been overweight (p = 0.002) were also of significance. However, with multiple linear regression analysis, only previous overweight status (MER less in dogs previously overweight p = 0.008) and breed (MER greater in Yorkshire terriers [p = 0.029] and less in Chihuahuas [p = 0.089]) remained in the final model. This study is the first to estimate MER in dogs of miniature breeds. Although further information from pet dogs is now needed, the current work will be useful for setting energy and nutrient requirement in such dogs for the future. Journal of Animal Physiology and Animal Nutrition © 2013 Blackwell Verlag GmbH.

  17. Miniature surgical robots in the era of NOTES and LESS: dream or reality?

    Science.gov (United States)

    Zygomalas, Apollon; Kehagias, Ioannis; Giokas, Konstantinos; Koutsouris, Dimitrios

    2015-02-01

    Laparoscopy is an established method for the treatment of numerous surgical conditions. Natural orifice transluminal endoscopic surgery (NOTES) is a novel surgical technique that uses the natural orifices of the human body as entrances to the abdominal cavity. An alternative concept of minimally invasive approach to the abdominal cavity is to insert all the laparoscopic instruments through ports using a single small incision on the abdominal wall. A suggested name for this technique is laparoendoscopic single-site surgery (LESS). Considering the technical difficulties in NOTES and LESS and the progress in informatics and robotics, the use of robots seems ideal. The aim of this study is to investigate if there is at present, a realistic possibility of using miniature robots in NOTES or LESS in daily clinical practice. An up-to-date review on in vivo surgical miniature robots is made. A Web-based research of the English literature up to March 2013 using PubMed, Scopus, and Google Scholar as search engines was performed. The development of in vivo miniature robots for use in NOTES or LESS is a reality with great advancements, potential advantages, and possible application in minimally invasive surgery in the future. However, true totally NOTES or LESS procedures on humans using miniature robots either solely or as assistance, remain a dream at present. © The Author(s) 2014.

  18. Digital Heart-Rate Variability Parameter Monitoring and Assessment ASIC.

    Science.gov (United States)

    Massagram, W; Hafner, N; Mingqi Chen; Macchiarulo, L; Lubecke, V M; Boric-Lubecke, O

    2010-02-01

    This paper describes experimental results for an application-specific integrated circuit (ASIC), designed for digital heart rate variability (HRV) parameter monitoring and assessment. This ASIC chip measures beat-to-beat (RR) intervals and stores HRV parameters into its internal memory in real time. A wide range of short-term and long-term ECG signals obtained from Physionet was used for testing. The system detects R peaks with millisecond accuracy, and stores up to 2 min of continuous RR interval data and up to 4 min of RR interval histogram. The prototype chip was fabricated in a 0.5 ¿m complementary metal-oxide semiconductor technology on a 3×3 mm(2) die area, with a measured dynamic power consumption of 10 ¿W and measured leakage current of 2.62 nA. The HRV monitoring system including this HRV ASIC, an analog-to-digital converter, and a low complexity microcontroller was estimated to consume 32.5 ¿V, which is seven times lower power than a stand-alone microcontroller performing the same functions. Compact size, low cost, and low power consumption make this chip suitable for a miniaturized portable HRV monitoring system.

  19. Generation of miniaturized planar ecombinant antibody arrays using a microcantilever-based printer

    Science.gov (United States)

    Petersson, Linn; Berthet Duroure, Nathalie; Auger, Angèle; Dexlin-Mellby, Linda; Borrebaeck, Carl AK; Ait Ikhlef, Ali; Wingren, Christer

    2014-07-01

    Miniaturized (Ø 10 μm), multiplexed (>5-plex), and high-density (>100 000 spots cm-2) antibody arrays will play a key role in generating protein expression profiles in health and disease. However, producing such antibody arrays is challenging, and it is the type and range of available spotters which set the stage. This pilot study explored the use of a novel microspotting tool, BioplumeTM—consisting of an array of micromachined silicon cantilevers with integrated microfluidic channels—to produce miniaturized, multiplexed, and high-density planar recombinant antibody arrays for protein expression profiling which targets crude, directly labelled serum. The results demonstrated that 16-plex recombinant antibody arrays could be produced—based on miniaturized spot features (78.5 um2, Ø 10 μm) at a 7-125-times increased spot density (250 000 spots cm-2), interfaced with a fluorescent-based read-out. This prototype platform was found to display adequate reproducibility (spot-to-spot) and an assay sensitivity in the pM range. The feasibility of the array platform for serum protein profiling was outlined.

  20. Generation of miniaturized planar ecombinant antibody arrays using a microcantilever-based printer

    International Nuclear Information System (INIS)

    Petersson, Linn; Dexlin-Mellby, Linda; Borrebaeck, Carl AK; Wingren, Christer; Berthet Duroure, Nathalie; Auger, Angèle; Ait Ikhlef, Ali

    2014-01-01

    Miniaturized (Ø 10 μm), multiplexed (>5-plex), and high-density (>100 000 spots cm −2 ) antibody arrays will play a key role in generating protein expression profiles in health and disease. However, producing such antibody arrays is challenging, and it is the type and range of available spotters which set the stage. This pilot study explored the use of a novel microspotting tool, Bioplume TM —consisting of an array of micromachined silicon cantilevers with integrated microfluidic channels—to produce miniaturized, multiplexed, and high-density planar recombinant antibody arrays for protein expression profiling which targets crude, directly labelled serum. The results demonstrated that 16-plex recombinant antibody arrays could be produced—based on miniaturized spot features (78.5 um 2 , Ø 10 μm) at a 7–125-times increased spot density (250 000 spots cm −2 ), interfaced with a fluorescent-based read-out. This prototype platform was found to display adequate reproducibility (spot-to-spot) and an assay sensitivity in the pM range. The feasibility of the array platform for serum protein profiling was outlined. (paper)

  1. AMINA-chip : a miniaturized measurement system for ambient ammonia

    NARCIS (Netherlands)

    Timmer, Björn Herman

    2004-01-01

    The development of a miniaturized and integrated measurement system for gaseous ammonia is described in this thesis. The measuring principle, ¿AMINA¿, is an indirect method for selectively measuring ammonia that makes use of pH-transitions, electrolyte conductivity detection and phaseseparating

  2. Testing the impact of miniaturization on phylogeny: Paleozoic dissorophoid amphibians.

    Science.gov (United States)

    Fröbisch, Nadia B; Schoch, Rainer R

    2009-06-01

    Among the diverse clade of Paleozoic dissorophoid amphibians, the small, terrestrial amphibamids and the neotenic branchiosaurids have frequently been suggested as possible antecedents of either all or some of the modern amphibian clades. Classically, amphibamids and branchiosaurids have been considered to represent distinct, but closely related clades within dissorophoids, but despite their importance for the controversial lissamphibian origins, a comprehensive phylogenetic analysis of small dissorophoids has thus far not been attempted. On the basis of an integrated data set, the relationships of amphibamids and branchiosaurids were analyzed using parsimony and Bayesian approaches. Both groups represent miniaturized forms and it was tested whether similar developmental pathways, associated with miniaturization, lead to an artificial close relationship of branchiosaurids and amphibamids. Moreover, the fit of the resulting tree topologies to the distribution of fossil taxa in the stratigraphic rock record was assessed as an additional source of information. The results show that characters associated with a miniaturized morphology are not responsible for the close clustering of branchiosaurids and amphibamids. Instead, all analyses invariably demonstrate a monophyletic clade of branchiosaurids highly nested within derived amphibamids, indicating that branchiosaurids represent a group of secondarily neotenic amphibamid dissorophoids. This understanding of the phylogenetic relationships of small dissorophoid amphibians provides a new framework for the discussion of their evolutionary history and the evolution of characters shared by branchiosaurids and/or amphibamids with modern amphibian taxa.

  3. Deriving Snow-Cover Depletion Curves for Different Spatial Scales from Remote Sensing and Snow Telemetry Data

    Science.gov (United States)

    Fassnacht, Steven R.; Sexstone, Graham A.; Kashipazha, Amir H.; Lopez-Moreno, Juan Ignacio; Jasinski, Michael F.; Kampf, Stephanie K.; Von Thaden, Benjamin C.

    2015-01-01

    During the melting of a snowpack, snow water equivalent (SWE) can be correlated to snow-covered area (SCA) once snow-free areas appear, which is when SCA begins to decrease below 100%. This amount of SWE is called the threshold SWE. Daily SWE data from snow telemetry stations were related to SCA derived from moderate-resolution imaging spectro radiometer images to produce snow-cover depletion curves. The snow depletion curves were created for an 80,000 sq km domain across southern Wyoming and northern Colorado encompassing 54 snow telemetry stations. Eight yearly snow depletion curves were compared, and it is shown that the slope of each is a function of the amount of snow received. Snow-cover depletion curves were also derived for all the individual stations, for which the threshold SWE could be estimated from peak SWE and the topography around each station. A stations peak SWE was much more important than the main topographic variables that included location, elevation, slope, and modelled clear sky solar radiation. The threshold SWE mostly illustrated inter-annual consistency.

  4. Analysis of serum and cerebrospinal fluid in clinically normal adult miniature donkeys.

    Science.gov (United States)

    Mozaffari, A A; Samadieh, H

    2013-09-01

    To establish reference intervals for serum and cerebrospinal fluid (CSF) parameters in clinically healthy adult miniature donkeys. Experiments were conducted on 10 female and 10 male clinically normal adult miniature donkeys, randomly selected from five herds. Lumbosacral CSF collection was performed with the sedated donkey in the standing position. Cell analysis was performed immediately after the samples were collected. Blood samples were obtained from the jugular vein immediately after CSF sample collection. Sodium, potassium, glucose, urea nitrogen, total protein, calcium, chloride, phosphorous and magnesium concentrations were measured in CSF and serum samples. A paired t-test was used to compare mean values between female and male donkeys. The CSF was uniformly clear, colourless and free from flocculent material, with a specific gravity of 1.002. The range of total nucleated cell counts was 2-4 cells/μL. The differential white cell count comprised only small lymphocytes. No erythrocytes or polymorphonuclear cells were observed on cytological examination. Reference values were obtained for biochemical analysis of serum and CSF. Gender had no effect on any variables measured in serum or CSF (p>0.05). CSF analysis can provide important information in addition to that gained by clinical examination. CSF analysis has not previously been performed in miniature donkeys; this is the first report on the subject. In the present study, reference intervals for total nucleated cell count, total protein, glucose, urea nitrogen, sodium, potassium, chloride, calcium, phosphorous and magnesium concentrations of serum and CSF were determined for male and female miniature donkeys.

  5. Kısa Mesafe RF Algılayıcı ile Telemetri Uygulaması

    Directory of Open Access Journals (Sweden)

    Muhammet Sinan BAŞARSLAN

    2016-03-01

    Full Text Available Bu çalışmada, Telemetri bir sistem ya da tesisin, uzaktan kablo veya kablosuz olarak izlenmesi ve/veya kontrol edilmesidir. Uygulama alanları olarak petrol, su veya gaz boru hatlarının izlenmesi, uydu ve telekom antenlerinin izlenmesi, içme veya atık su tesislerinin izlenmesi sayılabilir. Günümüzde çoğunlukla kablosuz (wireless haberleşme tercih edilmektedir. Kablosuz iletişim teknolojilerinden de en yaygın kullanılanları bluetooth, radyo modem cihazları, GSM sistemleridir.Haberleşme yapılacak olan arazi düz olmak zorunda değildir. Antenler arasında dağ, tepe vb. haberleşmeyi engelleyici unsurlar olsa bile repeater özellikli RF data modemler ile bu tür engeller aşılabilmektedir. Bu sayede noktalar arası uzaklıklar kilometrelerce olabilir.Sunulan uygulamada telemetri yöntemi ile bir model araca dair verilerin uzak bir noktada bulunan Android işletim sistemli bir mobil cihaz üzerinden izlenmesi gerçekleştirilmiştir. Uzaktan izleme işlemleri için kısa mesafe RF teknolojisi (433 MHz kullanılmıştır.

  6. Design of a miniaturized integrated spectrometer for spectral tissue sensing

    Science.gov (United States)

    Belay, Gebirie Yizengaw; Hoving, Willem; Ottevaere, Heidi; van der Put, Arthur; Weltjens, Wim; Thienpont, Hugo

    2016-04-01

    Minimally-invasive image-guided procedures become increasingly used by physicians to obtain real-time characterization feedback from the tissue at the tip of their interventional device (needle, catheter, endoscopic or laparoscopic probes, etc…) which can significantly improve the outcome of diagnosis and treatment, and ultimately reduce cost of the medical treatment. Spectral tissue sensing using compact photonic probes has the potential to be a valuable tool for screening and diagnostic purposes, e.g. for discriminating between healthy and tumorous tissue. However, this technique requires a low-cost broadband miniature spectrometer so that it is commercially viable for screening at point-of-care locations such as physicians' offices and outpatient centers. Our goal is therefore to develop a miniaturized spectrometer based on diffractive optics that combines the functionalities of a visible/near-infrared (VIS/NIR) and shortwave-infrared (SWIR) spectrometer in one very compact housing. A second goal is that the hardware can be produced in high volume at low cost without expensive time consuming alignment and calibration steps. We have designed a miniaturized spectrometer which operates both in the visible/near-infrared and shortwave-infrared wavelength regions ranging from 400 nm to 1700 nm. The visible/near-infrared part of the spectrometer is designed for wavelengths from 400 nm to 800 nm whereas the shortwave-infrared segment ranges from 850 nm to 1700 nm. The spectrometer has a resolution of 6 nm in the visible/near-infrared wavelength region and 10 nm in the shortwave-infrared. The minimum SNR of the spectrometer for the intended application is about 151 in the VIS/NIR range and 6000 for SWIR. In this paper, the modelling and design, and power budget analysis of the miniaturized spectrometer are presented. Our work opens a door for future affordable micro- spectrometers which can be integrated with smartphones and tablets, and used for point

  7. Miniature photometric stereo system for textile surface structure reconstruction

    Science.gov (United States)

    Gorpas, Dimitris; Kampouris, Christos; Malassiotis, Sotiris

    2013-04-01

    In this work a miniature photometric stereo system is presented, targeting the three-dimensional structural reconstruction of various fabric types. This is a supportive module to a robot system, attempting to solve the well known "laundry problem". The miniature device has been designed for mounting onto the robot gripper. It is composed of a low-cost off-the-shelf camera, operating in macro mode, and eight light emitting diodes. The synchronization between image acquisition and lighting direction is controlled by an Arduino Nano board and software triggering. The ambient light has been addressed by a cylindrical enclosure. The direction of illumination is recovered by locating the reflection or the brightest point on a mirror sphere, while a flatfielding process compensates for the non-uniform illumination. For the evaluation of this prototype, the classical photometric stereo methodology has been used. The preliminary results on a large number of textiles are very promising for the successful integration of the miniature module to the robot system. The required interaction with the robot is implemented through the estimation of the Brenner's focus measure. This metric successfully assesses the focus quality with reduced time requirements in comparison to other well accepted focus metrics. Besides the targeting application, the small size of the developed system makes it a very promising candidate for applications with space restrictions, like the quality control in industrial production lines or object recognition based on structural information and in applications where easiness in operation and light-weight are required, like those in the Biomedical field, and especially in dermatology.

  8. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    Science.gov (United States)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  9. The mass miniature chest radiography programme in Cape Town ...

    African Journals Online (AJOL)

    Background. Tuberculosis (TB) control programmes rely mainly on passive detection of symptomatic individuals. The resurgence of TB has rekindled interest in active case finding. Cape Town (South Africa) had a mass miniature radiography (MMR) screening programme from 1948 to 1994. Objective. To evaluate screening ...

  10. Disposable Miniaturized Screen‐Printed pH and Reference Electrodes for Potentiometric Systems

    DEFF Research Database (Denmark)

    Musa, Arnaud Emmanuel; del Campo, Francisco Javier; Abramova, Natalia

    2011-01-01

    This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi‐reference electrode (QRE) coupled to a solid‐state ion‐selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen‐printing...... electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 °C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open‐circuit‐potential standard deviation of ±1.2 mV over...

  11. A Queriable Repository for HST Telemetry Data, a Case Study in using Data Warehousing for Science and Engineering

    Science.gov (United States)

    Pollizzi, J. A.; Lezon, K.

    The Hubble Space Telescope (HST) generates on the order of 7,000 telemetry values, many of which are sampled at 1Hz, and with several hundred parameters being sampled at 40Hz. Such data volumes would quickly tax even the largest of processing facilities. Yet the ability to access the telemetry data in a variety of ways, and in particular, using ad hoc (i.e., no a priori fixed) queries, is essential to assuring the long term viability and usefulness of this instrument. As part of the recent NASA initiative to re-engineer HST's ground control systems, a concept arose to apply newly available data warehousing technologies to this problem. The Space Telescope Science Institute was engaged to develop a pilot to investigate the technology and to create a proof-of-concept testbed that could be demonstrated and evaluated for operational use. This paper describes this effort and its results.

  12. Adeno-associated virus transformation into the normal miniature pig and the normal guinea pigs cochlea via scala tympani.

    Science.gov (United States)

    Shi, Xunbei; Wu, Nan; Zhang, Yue; Guo, Weiwei; Lin, Chang; Yang, Shiming

    2017-09-01

    To investigate the expression of the miniature pig cochlea after AAV1 transfect into the cochlea via round window membrane (RWM). Twenty miniature pigs are equally divided into four experimental groups. Twelve miniature pigs are equally divided into four control groups. Each pig was transfected with the AAV1 in the experimental group via RWM and each pig was transduced with the artificial perilymph in the control group. The expression of green fluorescent protein (GFP) was observed at 2 weeks, 3 weeks and 4 weeks, respectively. Likewise, AAV1 was delivered into the guinea pigs cochleas using the same method, and the results were compared with that of the miniature pigs. The expression was mainly in the inner hair cells of the miniature pig. The expression of GFP began to appear at 2 weeks, reached the peak at 3 weeks. It also expressed in Hensen's cells, inner pillar cells, outer pillar cells, spiral limbus, and spiral ligament. In the meanwhile, AAV1 was delivered into guinea pig cochlea via the same method, and AAV1 was also expressed in the inner hair cells. But the expression peaked at 2 weeks, and the efficiency of the inner hair cell transfection was higher than that of the pig. AAV1 can be transformed into miniature pig cochlea via scala tympani by the RWM method efficiently.

  13. Development of a miniature autofluorescence device for the early diagnosis of squamous cell carcinoma

    Science.gov (United States)

    Patil, Ajeetkumar; Rao K., Swati; V. K., Unnikrishnan; Pai, Keerthilatha M.; Kartha, V. B.; Chidangil, Santhosh

    2017-07-01

    Autofluorescence spectroscopy offer noninvasive and promising tools for the detection of alternations biochemical compositions of tissues and cells, in presence of disease. They have the added advantage of being highly objective due to the fact that diagnostic evaluation is by statistical methods, eliminating errors from lack of experience, fatigue factor, and subjectivity of visual perceptions. The present research work involves in designing and assembling of a low cost, miniature oral cancer screening device with for routine clinical applications. A miniature system was designed and assembled with much smaller and cost-effective components like compact light source and miniature spectrometer, in a hand-held unit configuration. The performance of the system was evaluated using animal -mouse- SCC model. The current system can be used in handheld operation, which makes it very useful for many applications like, screening of squamous cell carcinoma susceptible population.

  14. Sea Turtle Satellite Telemetry Data in North Atlantic Ocean from 2007-10-16 to 2010-11-26 (NCEI Accession 0159216)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains satellite telemetry data for sea turtles. Movements, migratory pathways, and foraging behavior of sea turtles were tracked and surfacing...

  15. Miniature sources of irradiation for intracavitary thermo radiotherapy

    Science.gov (United States)

    Taubin, M.; Chesnokov, D.; Simonov, A.

    2018-02-01

    This report presents the development of a miniature ionizing and thermal radiation source for oncological diseases treatment namely the inward parts of the body. This source can be placed next to the tumor inside of the body. This report is only about methods and devices for the intracavitary therapy. Irradiation by external sources wasn’t considered in our investigation.

  16. Evaluating harvest-based control of invasive fish with telemetry: Performance of sea lamprey traps in the Great Lakes

    Science.gov (United States)

    Holbrook, Christopher; Bergstedt, Roger A.; Barber, Jessica M.; Bravener, Gale A; Jones, Michael L.; Krueger, Charles C.

    2016-01-01

    Physical removal (e.g., harvest via traps or nets) of mature individuals may be a cost-effective or socially acceptable alternative to chemical control strategies for invasive species, but requires knowledge of the spatial distribution of a population over time. We used acoustic telemetry to determine the current and possible future role of traps to control and assess invasive sea lampreys, Petromyzon marinus, in the St. Marys River, the connecting channel between Lake Superior and Lake Huron. Exploitation rates (i.e., fractions of an adult sea lamprey population removed by traps) at two upstream locations were compared among three years and two points of entry to the system. Telemetry receivers throughout the drainage allowed trap performance (exploitation rate) to be partitioned into two components: proportion of migrating sea lampreys that visited trap sites (availability) and proportion of available sea lampreys that were caught by traps (local trap efficiency). Estimated exploitation rates were well below those needed to provide population control in the absence of lampricides and were limited by availability and local trap efficiency. Local trap efficiency estimates for acoustic-tagged sea lampreys were lower than analogous estimates regularly obtained using traditional mark–recapture methods, suggesting that abundance had been previously underestimated. Results suggested major changes would be required to substantially increase catch, including improvements to existing traps, installation of new traps, or other modifications to attract and retain more sea lampreys. This case study also shows how bias associated with telemetry tags can be estimated and incorporated in models to improve inferences about parameters that are directly relevant to fishery management.

  17. Miniaturized Spacecraft Platform for Command, Data Handling and Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Microelectronics Research Development Corporation (Micro RDC) proposes to develop a platform of low mass/volume/power, reliable miniaturized electronic modules that...

  18. Long Life Miniature Hall Thruster Enabling Low Cost Human Precursor Missions

    Data.gov (United States)

    National Aeronautics and Space Administration — Key and Central Objectives: This investigation aims to demonstrate that the application of magnetic shielding technology on miniature Hall thrusters will...

  19. X-36 Carried Aloft by Helicopter during Radio and Telemetry Tests

    Science.gov (United States)

    1996-01-01

    A Bell UH-1 helicopter lifts the X-36 Tailless Fighter Agility Research Aircraft off the ground for radio frequency and telemetry tests above Rogers Dry Lake at NASA Dryden Flight Research Center, Edwards, California, in November 1996. The purpose of taking the X-36 aloft for the radio and telemetry system checkouts was to test the systems more realistically while airborne. More taxi and radio frequency tests were conducted before the aircraft's first flight in early 1997. The NASA/Boeing X-36 Tailless Fighter Agility Research Aircraft program successfully demonstrated the tailless fighter design using advanced technologies to improve the maneuverability and survivability of possible future fighter aircraft. The program met or exceeded all project goals. For 31 flights during 1997 at the Dryden Flight Research Center, Edwards, California, the project team examined the aircraft's agility at low speed / high angles of attack and at high speed / low angles of attack. The aircraft's speed envelope reached up to 206 knots (234 mph). This aircraft was very stable and maneuverable. It handled very well. The X-36 vehicle was designed to fly without the traditional tail surfaces common on most aircraft. Instead, a canard forward of the wing was used as well as split ailerons and an advanced thrust-vectoring nozzle for directional control. The X-36 was unstable in both pitch and yaw axes, so an advanced, single-channel digital fly-by-wire control system (developed with some commercially available components) was put in place to stabilize the aircraft. Using a video camera mounted in the nose of the aircraft and an onboard microphone, the X-36 was remotely controlled by a pilot in a ground station virtual cockpit. A standard fighter-type head-up display (HUD) and a moving-map representation of the vehicle's position within the range in which it flew provided excellent situational awareness for the pilot. This pilot-in-the-loop approach eliminated the need for expensive and

  20. Miniature Heat Pipes

    Science.gov (United States)

    1997-01-01

    Small Business Innovation Research contracts from Goddard Space Flight Center to Thermacore Inc. have fostered the company work on devices tagged "heat pipes" for space application. To control the extreme temperature ranges in space, heat pipes are important to spacecraft. The problem was to maintain an 8-watt central processing unit (CPU) at less than 90 C in a notebook computer using no power, with very little space available and without using forced convection. Thermacore's answer was in the design of a powder metal wick that transfers CPU heat from a tightly confined spot to an area near available air flow. The heat pipe technology permits a notebook computer to be operated in any position without loss of performance. Miniature heat pipe technology has successfully been applied, such as in Pentium Processor notebook computers. The company expects its heat pipes to accommodate desktop computers as well. Cellular phones, camcorders, and other hand-held electronics are forsible applications for heat pipes.

  1. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  2. Flexible network wireless transceiver and flexible network telemetry transceiver

    Science.gov (United States)

    Brown, Kenneth D.

    2008-08-05

    A transceiver for facilitating two-way wireless communication between a baseband application and other nodes in a wireless network, wherein the transceiver provides baseband communication networking and necessary configuration and control functions along with transmitter, receiver, and antenna functions to enable the wireless communication. More specifically, the transceiver provides a long-range wireless duplex communication node or channel between the baseband application, which is associated with a mobile or fixed space, air, water, or ground vehicle or other platform, and other nodes in the wireless network or grid. The transceiver broadly comprises a communication processor; a flexible telemetry transceiver including a receiver and a transmitter; a power conversion and regulation mechanism; a diplexer; and a phased array antenna system, wherein these various components and certain subcomponents thereof may be separately enclosed and distributable relative to the other components and subcomponents.

  3. Digital Preservation of Ancient Maya Cave Architecture: Recent Field Efforts in Quintana Roo, Mexico

    Science.gov (United States)

    Rissolo, D.; Lo, E.; Hess, M. R.; Meyer, D. E.; Amador, F. E.

    2017-08-01

    The presence of ancient Maya shrines in caves serves as unequivocal evidence for the ritual appropriation of these subterranean spaces and their significance with respect to Maya religious practice. Detailed study of the miniature masonry temples and altar features in the caves of Quintana Roo, Mexico reveals a strong stylistic and likely functional correspondence between these structures and their terrestrial counterparts at Postclassic sites. The Proyecto Arquitectura Subterranea de Quintana Roo (coordinated by the Center of Interdisciplinary Science for Art, Architecture, and Archaeology, or CISA3, at the University of California, San Diego and in collaboration with the Instituto Nacional de Antropologia e Historia in Mexico) is conducting a survey and program of digital documentation of both the pristine and impacted cave shrines of the region. Once an area is developed and populated, and access is opened to caves containing ancient architectural features, they are soon vandalized - often resulting in the complete obliteration of these rare miniature buildings and their diagnostic architectural elements. This emergent situation necessitates the use of rapid reality-capture tools; however, the physical challenges of working in caves requires researchers of adapt increasingly common architectural documentation methodologies to more adverse field conditions.

  4. Ultrathin Graphene-Protein Supercapacitors for Miniaturized Bioelectronics.

    Science.gov (United States)

    Mosa, Islam M; Pattammattel, Ajith; Kadimisetty, Karteek; Pande, Paritosh; El-Kady, Maher F; Bishop, Gregory W; Novak, Marc; Kaner, Richard B; Basu, Ashis K; Kumar, Challa V; Rusling, James F

    2017-09-06

    Nearly all implantable bioelectronics are powered by bulky batteries which limit device miniaturization and lifespan. Moreover, batteries contain toxic materials and electrolytes that can be dangerous if leakage occurs. Herein, an approach to fabricate implantable protein-based bioelectrochemical capacitors (bECs) employing new nanocomposite heterostructures in which 2D reduced graphene oxide sheets are interlayered with chemically modified mammalian proteins, while utilizing biological fluids as electrolytes is described. This protein-modified reduced graphene oxide nanocomposite material shows no toxicity to mouse embryo fibroblasts and COS-7 cell cultures at a high concentration of 1600 μg mL -1 which is 160 times higher than those used in bECs, unlike the unmodified graphene oxide which caused toxic cell damage even at low doses of 10 μg mL -1 . The bEC devices are 1 μm thick, fully flexible, and have high energy density comparable to that of lithium thin film batteries. COS-7 cell culture is not affected by long-term exposure to encapsulated bECs over 4 d of continuous charge/discharge cycles. These bECs are unique, protein-based devices, use serum as electrolyte, and have the potential to power a new generation of long-life, miniaturized implantable devices.

  5. Miniature Non-Intrusive Multi-Parameter Oronasal Respiratory Health Monitor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Redondo Optics Inc. (ROI), proposes to develop, demonstrate, and deliver to NASA an intrinsically safe, miniature, low power, autonomous, and self-calibrated,...

  6. Challenges in miniaturized automotive long-range lidar system design

    Science.gov (United States)

    Fersch, Thomas; Weigel, Robert; Koelpin, Alexander

    2017-05-01

    This paper discusses the current technical limitations posed on endeavors to miniaturize lidar systems for use in automotive applications and how to possibly extend those limits. The focus is set on long-range scanning direct time of flight LiDAR systems using APD photodetectors. Miniaturization evokes severe problems in ensuring absolute laser safety while maintaining the systems' performance in terms of maximum range, signal-to-noise ratio, detection probability, pixel density, or frame rate. Based on hypothetical but realistic specifications for an exemplary system the complete lidar signal path is calculated. The maximum range of the system is used as a general performance indicator. It is determined with the minimum signal-to-noise ratio required to detect an object. Various system parameters are varied to find their impact on the system's range. The reduction of the laser's pulse width and the right choice for the transimpedance amplifier's amplification have shown to be practicable measures to double the system's range.

  7. Assessing the use of Low Voltage UV-light Emitting Miniature LEDs for Marine Biofouling Control

    Science.gov (United States)

    2016-07-01

    of that required to drive traditional UV mercury lamps . Secondly, given their small size and relatively low cost, UV LEDs provide ease of maintenance...UNCLASSIFIED UNCLASSIFIED Assessing the use of Low Voltage UV -light Emitting Miniature LEDs for Marine Biofouling Control Richard...settling organisms. The introduction of miniature UV light emitting diodes ( LEDs ) as a light source enables them to be embedded into thin, flexible

  8. Miniaturized Ultrasound Imaging Probes Enabled by CMUT Arrays with Integrated Frontend Electronic Circuits

    Science.gov (United States)

    Khuri-Yakub, B. (Pierre) T.; Oralkan, Ömer; Nikoozadeh, Amin; Wygant, Ira O.; Zhuang, Steve; Gencel, Mustafa; Choe, Jung Woo; Stephens, Douglas N.; de la Rama, Alan; Chen, Peter; Lin, Feng; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai; Shivkumar, Kalyanam; Mahajan, Aman; Seo, Chi Hyung; O’Donnell, Matthew; Truong, Uyen; Sahn, David J.

    2010-01-01

    Capacitive micromachined ultrasonic transducer (CMUT) arrays are conveniently integrated with frontend integrated circuits either monolithically or in a hybrid multichip form. This integration helps with reducing the number of active data processing channels for 2D arrays. This approach also preserves the signal integrity for arrays with small elements. Therefore CMUT arrays integrated with electronic circuits are most suitable to implement miniaturized probes required for many intravascular, intracardiac, and endoscopic applications. This paper presents examples of miniaturized CMUT probes utilizing 1D, 2D, and ring arrays with integrated electronics. PMID:21097106

  9. Miniature fuel cells relieve gas pressure in sealed batteries

    Science.gov (United States)

    Frank, H. A.

    1971-01-01

    Miniature fuel cells within sealed silver zinc batteries consume evolved hydrogen and oxygen rapidly, preventing pressure rupturing. They do not significantly increase battery weight and they operate in all battery life phases. Complete gas pressure control requires two fuel cells during all phases of operation of silver zinc batteries.

  10. Small scale monitoring of a bioremediation barrier using miniature electrical resistivity tomography

    Science.gov (United States)

    Sentenac, Philippe; Hogson, Tom; Keenan, Helen; Kulessa, Bernd

    2015-04-01

    The aim of this study was to assess, in the laboratory, the efficiency of a barrier of oxygen release compound (ORC) to block and divert a diesel plume migration in a scaled aquifer model using miniature electrical resistivity tomography (ERT) as the monitoring system. Two plumes of contaminant (diesel) were injected in a soil model made of local sand and clay. The diesel plumes migration was imaged and monitored using a miniature resistivity array system that has proved to be accurate in soil resistivity variations in small-scaled models of soil. ERT results reflected the lateral spreading and diversion of the diesel plumes in the unsaturated zone. One of the contaminant plumes was partially blocked by the ORC barrier and a diversion and reorganisation of the diesel in the soil matrix was observed. The technique of time-lapse ERT imaging showed that a dense non-aqueous phase liquid (DNAPL) contaminant like diesel can be monitored through a bioremediation barrier and the technique is well suited to monitor the efficiency of the barrier. Therefore, miniature ERT as a small-scale modelling tool could complement conventional techniques, which require more expensive and intrusive site investigation prior to remediation.

  11. The concept and application of miniaturization boiling in cooling system

    International Nuclear Information System (INIS)

    Suhaimi Illias; Muhammad Asri Idris

    2009-01-01

    The purpose of this research is to study and examine the phenomena of miniaturization-boiling, which intensely scatters with a large number of minute liquid particles from a water droplet surface to the atmosphere, when the droplet collided with a heating surface. As the material of the heating surface, the following were used: stainless steel (SUS 303 A Cr=17%,Ni=8%), sapphire (Al 3 O 2 ), brass, copper and carbon plane. The material was heated in order to study the miniaturization-boiling and droplet bounding phenomena at a very high temperature (160 degree C- 420 degree C). The phenomenon was photographed by a high-speed camera (10,000 fps) from the horizontal direction. The nuclear fusion reactor needs a very severe cooling, heat removal cooling method by special boiling is lead to this research. (Author)

  12. A Miniature Probe for Ultrasonic Penetration of a Single Cell

    Directory of Open Access Journals (Sweden)

    Mingfei Xiao

    2009-05-01

    Full Text Available Although ultrasound cavitation must be avoided for safe diagnostic applications, the ability of ultrasound to disrupt cell membranes has taken on increasing significance as a method to facilitate drug and gene delivery. A new ultrasonic resonance driving method is introduced to penetrate rigid wall plant cells or oocytes with springy cell membranes. When a reasonable design is created, ultrasound can gather energy and increase the amplitude factor. Ultrasonic penetration enables exogenous materials to enter cells without damaging them by utilizing instant acceleration. This paper seeks to develop a miniature ultrasonic probe experiment system for cell penetration. A miniature ultrasonic probe is designed and optimized using the Precise Four Terminal Network Method and Finite Element Method (FEM and an ultrasonic generator to drive the probe is designed. The system was able to successfully puncture a single fish cell.

  13. Development of a micromirror-scanned multimodal CARS miniaturized microscope for the in vivo study of spinal cord disorders

    Science.gov (United States)

    Murugkar, Sangeeta; Smith, Brett; Naji, Majid; Brideau, Craig; Stys, Peter; Anis, Hanan

    2011-03-01

    We discuss the design and implementation of a novel multimodal coherent anti-Stokes Raman scattering (CARS) miniaturized microscope for imaging of injured and recovering spinal cords in a single living animal. We demonstrate for the first time, the use of a biaxial microelectromechanical system (MEMS) mirror for scanning and diffraction limited multiple lens miniaturized objective for exciting a CARS signal. The miniaturized microscope design includes light delivery using a large mode area photonic crystal fiber (PCF), and multimode fiber for collection of the nonlinear optical signal. The basic design concept, major engineering challenges, solutions, and preliminary results are presented. We demonstrate CARS and two photon excitation fluorescence microscopy in a benchtop setup with the miniaturized optics and MEMS scanning. The light source is based on a single femtosecond laser (pump beam) and a supercontinuum generated in a nonlinear PCF (Stokes beam). This is coupled using free space optics onto the surface of a resonantly driven two dimensional scanning MEMS mirror that scans the excitation light in a Lissajous pattern. The novel design of the miniaturized microscope is expected to provide significant new information on the pathogenesis of demyelinating diseases such as Multiple Sclerosis and Spinal Cord Injury.

  14. Disposable Fluidic Actuators for Miniature In-Vivo Surgical Robotics.

    Science.gov (United States)

    Pourghodrat, Abolfazl; Nelson, Carl A

    2017-03-01

    Fusion of robotics and minimally invasive surgery (MIS) has created new opportunities to develop diagnostic and therapeutic tools. Surgical robotics is advancing from externally actuated systems to miniature in-vivo robotics. However, with miniaturization of electric-motor-driven surgical robots, there comes a trade-off between the size of the robot and its capability. Slow actuation, low load capacity, sterilization difficulties, leaking electricity and transferring produced heat to tissues, and high cost are among the key limitations of the use of electric motors in in-vivo applications. Fluid power in the form of hydraulics or pneumatics has a long history in driving many industrial devices and could be exploited to circumvent these limitations. High power density and good compatibility with the in-vivo environment are the key advantages of fluid power over electric motors when it comes to in-vivo applications. However, fabrication of hydraulic/pneumatic actuators within the desired size and pressure range required for in-vivo surgical robotic applications poses new challenges. Sealing these types of miniature actuators at operating pressures requires obtaining very fine surface finishes which is difficult and costly. The research described here presents design, fabrication, and testing of a hydraulic/pneumatic double-acting cylinder, a limited-motion vane motor, and a balloon-actuated laparoscopic grasper. These actuators are small, seal-less, easy to fabricate, disposable, and inexpensive, thus ideal for single-use in-vivo applications. To demonstrate the ability of these actuators to drive robotic joints, they were modified and integrated in a robotic arm. The design and testing of this surgical robotic arm are presented to validate the concept of fluid-power actuators for in-vivo applications.

  15. Circuits and Systems for Low-Power Miniaturized Wireless Sensors

    Science.gov (United States)

    Nagaraju, Manohar

    The field of electronic sensors has witnessed a tremendous growth over the last decade particularly with the proliferation of mobile devices. New applications in Internet of Things (IoT), wearable technology, are further expected to fuel the demand for sensors from current numbers in the range of billions to trillions in the next decade. The main challenges for a trillion sensors are continued miniaturization, low-cost and large-scale manufacturing process, and low power consumption. Traditional integration and circuit design techniques in sensor systems are not suitable for applications in smart dust, IoT etc. The first part of this thesis demonstrates an example sensor system for biosignal recording and illustrates the tradeoffs in the design of low-power miniaturized sensors. The different components of the sensor system are integrated at the board level. The second part of the thesis demonstrates fully integrated sensors that enable extreme miniaturization of a sensing system with the sensor element, processing circuitry, a frequency reference for communication and the communication circuitry in a single hermetically sealed die. Design techniques to reduce the power consumption of the sensor interface circuitry at the architecture and circuit level are demonstrated. The principles are used to design sensors for two of the most common physical variables, mass and pressure. A low-power wireless mass and pressure sensor suitable for a wide variety of biological/chemical sensing applications and Tire Pressure Monitoring Systems (TPMS) respectively are demonstrated. Further, the idea of using high-Q resonators for a Voltage Controlled Oscillator (VCO) is proposed and a low-noise, wide bandwidth FBAR-based VCO is presented.

  16. User-oriented end-to-end transport protocols for the real-time distribution of telemetry data from NASA spacecraft

    Science.gov (United States)

    Hooke, A. J.

    1979-01-01

    A set of standard telemetry protocols for downlink data flow facilitating the end-to-end transport of instrument data from the spacecraft to the user in real time is proposed. The direct switching of data by autonomous message 'packets' that are assembled by the source instrument on the spacecraft is discussed. The data system consists thus of a format on a message rather than word basis, and such packet telemetry would include standardized protocol headers. Standards are being developed within the NASA End-to-End Data System (NEEDS) program for the source packet and transport frame protocols. The source packet protocol contains identification of both the sequence number of the packet as it is generated by the source and the total length of the packet, while the transport frame protocol includes a sequence count defining the serial number of the frame as it is generated by the spacecraft data system, and a field specifying any 'options' selected in the format of the frame itself.

  17. A Miniaturize Bandpass Filter with Harmonic Suppression Using Meandered Quarter-Wavelength Resonators

    Directory of Open Access Journals (Sweden)

    Yun-Long Lu

    2014-01-01

    Full Text Available A miniaturized bandpass filter with harmonics suppression is presented. The proposed filter consists of two quarter-wavelength microstrip resonators, which are meandered for circuit size reduction. An interdigital capacitor, loading at zero-voltage point, is employed to provide the desired coupling between the resonators at operating frequency, whereas the coupling coefficient at the third harmonic is realized to be zero. Besides, the second and fourth harmonics are suppressed since λ/4 resonators are adopted. Benefiting from these properties, a miniaturized bandpass filter with the second, third, and fourth harmonics suppression was designed and implemented. The final measured and simulated results show good consistence with the theoretical counterparts.

  18. High Speed, Low Cost Telemetry Access from Space Development Update on Programmable Ultra Lightweight System Adaptable Radio (PULSAR)

    Science.gov (United States)

    Simms, William Herbert, III; Varnavas, Kosta; Eberly, Eric

    2014-01-01

    Software Defined Radio (SDR) technology has been proven in the commercial sector since the early 1990's. Today's rapid advancement in mobile telephone reliability and power management capabilities exemplifies the effectiveness of the SDR technology for the modern communications market. In contrast, the foundations of transponder technology presently qualified for satellite applications were developed during the early space program of the 1960's. Conventional transponders are built to a specific platform and must be redesigned for every new bus while the SDR is adaptive in nature and can fit numerous applications with no hardware modifications. A SDR uses a minimum amount of analog / Radio Frequency (RF) components to up/down-convert the RF signal to/from a digital format. Once the signal is digitized, all processing is performed using hardware or software logic. Typical SDR digital processes include; filtering, modulation, up/down converting and demodulation. NASA Marshall Space Flight Center (MSFC) Programmable Ultra Lightweight System Adaptable Radio (PULSAR) leverages existing MSFC SDR designs and commercial sector enhanced capabilities to provide a path to a radiation tolerant SDR transponder. These innovations (1) reduce the cost of NASA Low Earth Orbit (LEO) and Deep Space standard transponders, (2) decrease power requirements, and (3) commensurately reduce volume. A second pay-off is the increased SDR flexibility by allowing the same hardware to implement multiple transponder types simply by altering hardware logic - no change of hardware is required - all of which will ultimately be accomplished in orbit. Development of SDR technology for space applications will provide a highly capable, low cost transponder to programs of all sizes. The MSFC PULSAR Project results in a Technology Readiness Level (TRL) 7 low-cost telemetry system available to Smallsat and CubeSat missions, as well as other platforms. This paper documents the continued development and

  19. Miniature probe with semiconductor photodiode for measuring dose rates in radiotherapy

    International Nuclear Information System (INIS)

    Burian, A.

    1991-01-01

    The probe is designed for gaining information on the magnitude and spatial distribution of the dose which will be absorbed by the patient's body during radiotherapy. The probe satisfies requirements of high-level miniaturization and requirements on the shape and tissue-equivalence of the casing, as well as on efficient electromagnetic shielding. It is fitted with a miniature photodiode. Conductive carbon cement was used for attaching contacts to the photodiode. Efficient electromagnetic shielding was achieved by means of a carbon-based conductive layer. The photodiode casing was made from a mixture of organic materials whose biogenic elements approximate the standard soft human tissue. The geometry of the casing is adapted to the particular field of application of the probe. (Z.S). 2 figs

  20. Miniature GC: Minicell ion mobility spectrometer (IMS) for astrobiology planetary missions

    Science.gov (United States)

    Kojiro, Daniel R.; Holland, Paul M.; Stimac, Robert M.; Kaye, William J.; Takeuchi, Norishige

    2006-01-01

    Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or longer mission life for stationary landers/laboratories. We describe here the development of a miniature GC - Minicell Ion Mobility Spectrometer (IMS) under development through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA's Small Business Innovative Research (SBIR) Program.

  1. Novel Techniques for Retroperitoneal Implantation of Telemetry Transmitters for Physiologic Monitoring in Gottingen Minipigs (Sus scrofa domesticus)

    Science.gov (United States)

    2014-12-01

    that this procedure permitted effective monitoring of complex physiologic data, including transthoracic impedance, without negatively affecting the...retroperitoneal implantation of the telemetry device permitted effective monitoring of complex physiologic data, including transthoracic impedance...nerve agent and cyanide poisoning in minipigs after intraosseous administration. Ann Emerg Med 60:424–430. 26. Ngawhirunpat T, Opanasopit P

  2. Gravity Probe-B (GP-B) Mission and Tracking, Telemetry and Control Subsystem Overview

    Science.gov (United States)

    Kennedy, Paul; Bell, Joseph L. (Technical Monitor)

    2001-01-01

    The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) in Huntsville, Alabama will launch the Gravity Probe B (GP-B) space experiment in the Fall of 2002. The GP-B spacecraft was developed to prove Einstein's theory of General Relativity. This paper will provide an overview of the GPB mission and will discuss the design, and test of the spacecraft Tracking, Telemetry and Control (TT&C) subsystem which incorporates NASA's latest generation standard transponder for use with the NASA Tracking and Data Relay Satellite System (TDRSS).

  3. Feasibility of Determining Aerodynamic Coefficients for a NASA Apollo Body With the Use of Telemetry Data From Free Flight Range Testing

    National Research Council Canada - National Science Library

    Topper, Benjamin; Brown, T. G; Bukowski, Edward; Davis, Bradford S; Hall, Rex A; Muller, Peter C; Vong, Timothy T; Brandon, Fred J

    2007-01-01

    ... s) Langley Research Center to perform a free-flight experiment with telemetry (TM) instrumented sub-scaled re-entry vehicle in order to determine the feasibility of using TM to obtain aerodynamic coefficients...

  4. EPMT: a portable transfer standard for telemetry system pressure-transducer calibration

    International Nuclear Information System (INIS)

    Hasbrouck, R.T.

    1977-01-01

    The LLL developed electronic pressure meter (EPMT) is a portable static-pressure calibration instrument for use with the LLL telemetry transducer system at the Nevada Test Site (NTS). It is significantly more accurate and rugged than the bourdon-tube pressure gauge it replaces, and can be incorporated into a field-use, semi-automatic, pressure calibration system. The process by which a transducer is selected for EPMT use from the inventory of field-service-certified transducers and subjected to an extensive preconditioning and calibration procedure is described. By combining this unusual calibration procedure with a unique, statistically based data-reduction routine, the total uncertainty of the measuring process at each calibration point can be determined with high accuracy

  5. Some characteristics of a miniature neutron spectrometer

    International Nuclear Information System (INIS)

    Sekimoto, H.; Oishi, K.; Hojo, K.; Hojo, T.

    1984-01-01

    Some characteristics of an NE213 miniature spherical spectrometer for in-assembly fast-neutron spectrometry were measured. As the bubbling time changed, the pulse-height did not change appreciably, but the n-γ discrimination characteristics changed considerably. As the count rate changed, the pulse-height did not change appreciably, and the change of the n-γ discrimination characteristics was acceptable. The neutron response function was measured to be almost isotropic except for the backward direction. (orig.)

  6. Vestibular-evoked myogenic potentials in miniature pigs

    Directory of Open Access Journals (Sweden)

    Xi Shi

    2016-06-01

    Conclusion: The latencies and thresholds of VEMPs recorded from the neck extensor muscle and the masseter muscle appear to be comparable in normal adult Bama miniature pigs, although the amplitude recorded from the neck extensor muscle seems to be higher than that from the masseter muscle. However, because of their usually relatively superficial and easily accessible location, as well as their large volume and strong contractions, masseter muscles may be better target muscles for recording myogenic potentials.

  7. Evaluation of computed tomographic and radiographic myelography in normal miniature pigs

    International Nuclear Information System (INIS)

    Choi, M.H.; Lee, H.Y.; Kim, M.E.; Kim, J.Y.; Lee, N.S.; Chang, J.H.; Jung, J.H.; Choi, M.C.

    2010-01-01

    Evaluation of the myelography was studied in miniature pigs. Radiographs and computed tomographic (CT) images of the whole spine were obtained at clinically healthy twelve miniature pigs of 4 (8.7-10 kg) and 12 (26-31 kg) months. The assessments of the spinal cord were made in accordance with the Pavlov's method and compared area ratio [at spinal cord (SC), vertebral canal (VC) and vertebral body (VB)]. The Pavlov's ratio in the cervical spine was significant larger than that of thoracolumbar in radiographic myelography. On CT myelography, the area of the spinal cord had a significant difference between the cervical and thoracolumbar spine. Among the cervical spine, the ratios of spinal cord and vertebral body (SC : VB), vertebral canal and vertebral body (VC : VB) were minimum at the level of 4th cervical spine in both ages, while maximum at the level of 6th cervical spine in both months. In case of lumbar spine, the ratios of spinal cord and vertebral body (SC : VB) were the largest at the level of 4th lumbar spine in 4 months and at the level of 3rd lumbar spine in 12 months. In addition, the ratio of spinal cord and vertebral body (SC : VB) of the cervical spinal cord was significant lower at 4 months but the lumbar spinal cord showed lower pattern at 12 months old miniature pigs

  8. A novel 2nd-order bandpass MFSS filter with miniaturized structure

    Directory of Open Access Journals (Sweden)

    C. Y. Fang

    2015-08-01

    Full Text Available In order to effectively obtain a miniaturized structure and good filtering properties, we propose a novel 2nd-order bandpass metamaterial frequency selective surface (MFSS filter which contains two capacitive layers and one inductive layer, where there are multi-loop metallic patches as shunt capacitor C and planar wire grids as series inductor L respectively. Unlike the traditional operation way—the tuned elements used in resonant surface approximately equal to one wavelength in circumference and the structure thickness with a spacing of a quarter wavelength apart, by changing the value of L and C and matching multilayer dielectric to adjust the LC coupling resonance and the resonance impedance respectively, the proposed MFSS filter can achieves a miniatured structure with ideal bandpass properties. Measurement results of the fabricated prototype of the bandpass filter (BPF indicate that the dimension of the tuned element on resonant surface is approximately 0.025 wavelength, i.e., 0.025λ. At the same time, the filter has the stable center frequency of f0 = 1.53GHz and the transmittance of T ⩾ 96.3% and high Q-value for the TE/TM wave polarization at various incidence angles. The novel 2nd-order bandpass MFSS filter with miniaturized structure not only can decrease structure dimension, but also has a wide range of applications to microwave and infrared band.

  9. Comparison of Miniaturized and Conventional Asymmetrical Flow Field-Flow Fractionation (AF4 Channels for Nanoparticle Separations

    Directory of Open Access Journals (Sweden)

    Zengchao You

    2017-03-01

    Full Text Available The performance of a miniaturized channel for the separation of polymer and metal nanoparticles (NP using Asymmetrical Flow Field-Flow Fractionation (AF4 was investigated and compared with a conventional AF4 system. To develop standard separation methods, experimental parameters like cross flow, gradient profile and injection time were varied and optimized. Corresponding chromatographic parameters were calculated and compared. Our results indicate that the chromatographic resolution in the miniaturized channel is lower, whereas significantly shorter analyses time and less solvent consumption were obtained. Moreover, the limit of detection (LOD and limit of quantification (LOQ obtained from hyphenation with a UV-detector are obviously lower than in a conventional channel, which makes the miniaturized channel interesting for trace analysis.

  10. Anatomy of adult Megaphragma (Hymenoptera: Trichogrammatidae, one of the smallest insects, and new insight into insect miniaturization.

    Directory of Open Access Journals (Sweden)

    Alexey A Polilov

    Full Text Available The body size, especially in cases of extreme reduction, is an important characteristic that strongly determines the morphology, physiology, and biology of animals. Miniaturization is a widespread trend in animal evolution and one of the principal directions of evolution in insects. Miniaturization-related features of insect morphology have been subject to intensive studies during the last few years, but the structure of the smallest insects remains insufficiently known. It is especially important to study hymenopterans of the genus Megaphragma, which include the smallest flying insects and a species in which an almost anucleate nervous system was recently discovered. This article is the first detailed study of the external and internal morphology of adults of Megaphragma mymaripenne and M. amalphitanum using histological methods, 3D computer modeling and other techniques. It is shown that in spite of the extremely small size the organization of Megaphragma retains a considerkable level of structural complexity. On the other hand, miniaturization leads to re-organizations of several organ systems. Unique structural features related to miniaturization have been found in both species: lysis of cell bodies and nuclei of neurons at late stages of pupal development, absence of the heart, and considerable reductions in the set of muscles. Comparative analysis of structure in the smallest insects representing different taxa has revealed common features of the evolutionary process of miniaturization in insects.

  11. A Fluorescence Based Miniaturized Detection Module for Toxin Producing Algae

    Science.gov (United States)

    Zieger, S. E.; Mistlberger, G.; Troi, L.; Lang, A.; Holly, C.; Klimant, I.

    2016-12-01

    Algal blooms are sensitive to external environmental conditions and may pose a serious threat to marine and human life having an adverse effect on the ecosystem. Harmful algal blooms can produce different toxins, which can lead to massive fish kills or to human disorders. Facing these problems, miniaturized and low-cost instrumentation for an early detection and identification of harmful algae classes has become more important over the last years. 1,2Based on the characteristic pigment pattern of different algae classes, we developed a miniaturized detection module, which is able to detect and identify algae classes after analyzing their spectral behavior. Our device combines features of a flow-cytometer and fluorimeter and is build up as a miniaturized and low-cost device of modular design. Similar to a fluorimeter, it excites cells in the capillary with up to 8 different excitation wavelengths recording the emitted fluorescence at 4 different emission channels. Furthermore, the device operates in a flow-through mode similar to a flow-cytometer, however, using only low-cost elements such as LEDs and photodiodes. Due to its miniaturized design, the sensitivity and selectivity increase, whereas background effects are reduced. With a sampling frequency of 140 Hz, we try to detect and count particular cell events even at a concentration of 2 cells / 7.3 µL illuminated volume. Using a self-learning multivariate algorithm, the data are evaluated autonomously on the device enabling an in-situ analysis. The flexibility in choosing excitation and emission wavelengths as well as the high sampling rate enables laboratory applications such as measuring induction kinetics. However, in its first application, the device is part of an open and modular monitoring system enabling the sensing of chemical compounds such as toxic and essential Hg, Cd, Pb, As and Cu trace metal species, nutrients and species related to the carbon cycle, VOCs and potentially toxic algae classes (FP7

  12. A suite of standard post-tagging evaluation metrics can help assess tag retention for field-based fish telemetry research

    Science.gov (United States)

    Gerber, Kayla M.; Mather, Martha E.; Smith, Joseph M.

    2017-01-01

    Telemetry can inform many scientific and research questions if a context exists for integrating individual studies into the larger body of literature. Creating cumulative distributions of post-tagging evaluation metrics would allow individual researchers to relate their telemetry data to other studies. Widespread reporting of standard metrics is a precursor to the calculation of benchmarks for these distributions (e.g., mean, SD, 95% CI). Here we illustrate five types of standard post-tagging evaluation metrics using acoustically tagged Blue Catfish (Ictalurus furcatus) released into a Kansas reservoir. These metrics included: (1) percent of tagged fish detected overall, (2) percent of tagged fish detected daily using abacus plot data, (3) average number of (and percent of available) receiver sites visited, (4) date of last movement between receiver sites (and percent of tagged fish moving during that time period), and (5) number (and percent) of fish that egressed through exit gates. These metrics were calculated for one to three time periods: early ( 5 days early in the study. On average, tagged Blue Catfish visited 9 (50%) and 13 (72%) of 18 within-reservoir receivers early and at the end of the study, respectively. At the end of the study, 73% of all tagged fish were detected moving between receivers. Creating statistical benchmarks for individual metrics can provide useful reference points. In addition, combining multiple metrics can inform ecology and research design. Consequently, individual researchers and the field of telemetry research can benefit from widespread, detailed, and standard reporting of post-tagging detection metrics.

  13. ECG telemetry in conscious guinea pigs.

    Science.gov (United States)

    Ruppert, Sabine; Vormberge, Thomas; Igl, Bernd-Wolfgang; Hoffmann, Michael

    2016-01-01

    During preclinical drug development, monitoring of the electrocardiogram (ECG) is an important part of cardiac safety assessment. To detect potential pro-arrhythmic liabilities of a drug candidate and for internal decision-making during early stage drug development an in vivo model in small animals with translatability to human cardiac function is required. Over the last years, modifications/improvements regarding animal housing, ECG electrode placement, and data evaluation have been introduced into an established model for ECG recordings using telemetry in conscious, freely moving guinea pigs. Pharmacological validation using selected reference compounds affecting different mechanisms relevant for cardiac electrophysiology (quinidine, flecainide, atenolol, dl-sotalol, dofetilide, nifedipine, moxifloxacin) was conducted and findings were compared with results obtained in telemetered Beagle dogs. Under standardized conditions, reliable ECG data with low variability allowing largely automated evaluation were obtained from the telemetered guinea pig model. The model is sensitive to compounds blocking cardiac sodium channels, hERG K(+) channels and calcium channels, and appears to be even more sensitive to β-blockers as observed in dogs at rest. QT interval correction according to Bazett and Sarma appears to be appropriate methods in conscious guinea pigs. Overall, the telemetered guinea pig is a suitable model for the conduct of early stage preclinical ECG assessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Does malaria epidemiology project Cameroon as `Africa in miniature'?

    Indian Academy of Sciences (India)

    Cameroon, a west-central African country with a ∼20 million population, is commonly regarded as 'Africa in miniature' due to the extensive biological and cultural diversities of whole Africa being present in a single-country setting. This country is inhabited by ancestral human lineages in unique eco-climatic conditions and ...

  15. INSTRUMENTAL MINIATURES BY THE COMPOSER GHEORGHE NEAGA: BETWEEN THE OLD AND THE NEW

    Directory of Open Access Journals (Sweden)

    CHICIUC NATALIA

    2016-12-01

    Full Text Available The miniature occupies an important place in Gheorghe Neaga’s instrumental chamber repertoire. Th e number of his small creations is impressive, being found both in the teaching repertoire of artistic education institutions and in the artistsinstrumentalists’ concert repertoire. Dedicated to piano, violin and piano or other instruments, the pieces refl ect in a perfect measure the author’s artistic predilections, more or less infl uenced by the evolution of compositional techniques. On this line, the proposed objective in this article is to examine some unelucidated miniatures through the old-new binomial spectrum.

  16. External unit for a semi-implantable middle ear hearing device.

    Science.gov (United States)

    Garverick, S L; Kane, M; Ko, W H; Maniglia, A J

    1997-06-01

    A miniaturized, low-power external unit has been developed for the clinical trials of a semi-implantable middle ear electromagnetic hearing device (SIMEHD) which uses radio-frequency telemetry to couple sound signals to the internal unit. The external unit is based on a commercial hearing aid which provides proven audio amplification and compression. Its receiver is replaced by an application-specific integrated circuit (ASIC) which: 1) adjusts the direct-current bias of the audio input according to its peak value; 2) converts the audio signal to a one-bit digital form using sigma-delta modulation; 3) modulates the sigma-delta output with a radio-frequency (RF) oscillator; and 4) drives the external RF coil and tuning capacitor using a field-effect transistor operated in class D. The external unit functions as expected and has been used to operate bench-top tests to the SIMEHD. Measured current consumption is 1.65-2.15 mA, which projects to a battery lifetime of about 15 days. Bandwidth is 6 kHz and harmonic distortion is about 2%.

  17. A Molecular Diagnostic Test for Persistent Müllerian Duct Syndrome in Miniature Schnauzer Dogs

    OpenAIRE

    Pujar, S.; Meyers-Wallen, V.N.

    2009-01-01

    In persistent Müllerian duct syndrome (PMDS), Müllerian ducts fail to regress in males during sexual differentiation. In the canine miniature schnauzer model, PMDS is caused by a C to T transition in exon 3 of the Müllerian inhibiting substance type II receptor (MISRII), which introduces a DdeI restriction site. Here we report a molecular diagnostic test for PMDS in the miniature schnauzer to identify affected dogs and carriers. As our test results suggest that the mutation is identical by de...

  18. Electric field distribution and current emission in a miniaturized geometrical diode

    Science.gov (United States)

    Lin, Jinpu; Wong, Patrick Y.; Yang, Penglu; Lau, Y. Y.; Tang, W.; Zhang, Peng

    2017-06-01

    We study the electric field distribution and current emission in a miniaturized geometrical diode. Using Schwarz-Christoffel transformation, we calculate exactly the electric field inside a finite vacuum cathode-anode (A-K) gap with a single trapezoid protrusion on one of the electrode surfaces. It is found that there is a strong field enhancement on both electrodes near the protrusion, when the ratio of the A-K gap distance to the protrusion height d /h spot checked against COMSOL simulations. We calculate the effective field enhancement factor for the field emission current, by integrating the local Fowler-Nordheim current density along the electrode surfaces. We systematically examine the electric field enhancement and the current rectification of the miniaturized geometrical diode for various geometric dimensions and applied electric fields.

  19. Research and Development of Miniaturized Fuel Evaporation Closed Chamber for Motorcycle

    Directory of Open Access Journals (Sweden)

    Hong Bin

    2016-01-01

    Full Text Available With the increasingly serious environmental pollution, pollution emissions of motorcycles had gradually been concerned in all developed countries. But the fuel evaporative emissions had not attracted sufficient attention and its test equipment was far from perfect. Thus, this paper addressed the miniaturized problems of closed chamber. On the basis of analyzing fuel evaporative emission regulations and the features of closed room, technical solutions are determined and a prototype was successfully developed. The paper successfully resolved the seal problem and innovatively developed the pressure balance system and the temperature and humidity regulation system. After experimental verification, the prototype had reliable performance and stable operation. And it met the requirements of the relevant standards and it was also equivalent to imported equipments. Thus, this paper successfully resolved the miniaturized problems of closed chamber.

  20. Discovery of skin alkaloids in a miniaturized eleutherodactylid frog from Cuba.

    Science.gov (United States)

    Rodríguez, Ariel; Poth, Dennis; Schulz, Stefan; Vences, Miguel

    2011-06-23

    Four phylogenetically independent lineages of frogs are currently known to sequester lipid-soluble skin alkaloids for which a dietary source has been demonstrated. We report here a remarkable fifth such instance, in Eleutherodactylus iberia and Eleutherodactylus orientalis, two species of miniaturized frogs of the family Eleutherodactylidae from Cuba. Six pumiliotoxins and two indolizidines were found in E. iberia, one of the smallest frogs in the world and characterized by a contrasting colour pattern for which we hypothesize an aposematic function. Analyses of stomach content indicated a numerical prevalence of mites with an important proportion of oribatids-a group of arthropods known to contain one of the pumiliotoxins detected in E. iberia. This suggests that miniaturization and specialization to small prey may have favoured the acquisition of dietary skin alkaloids in these amphibians.

  1. Improving the Automatic Inversion of Digital Alouette/ISIS Ionogram Reflection Traces into Topside Electron Density Profiles

    Science.gov (United States)

    Benson, Robert F.; Truhlik, Vladimir; Huang, Xueqin; Wang, Yongli; Bilitza, Dieter

    2012-01-01

    The topside sounders of the International Satellites for Ionospheric Studies (ISIS) program were designed as analog systems. The resulting ionograms were displayed on 35 mm film for analysis by visual inspection. Each of these satellites, launched between 1962 and 1971, produced data for 10 to 20 years. A number of the original telemetry tapes from this large data set have been converted directly into digital records. Software, known as the Topside Ionogram Scalar With True-Height (TOPIST) algorithm, has been produced and used for the automatic inversion of the ionogram reflection traces on more than 100,000 ISIS-2 digital topside ionograms into topside vertical electron density profiles Ne(h). Here we present some topside ionospheric solar cycle variations deduced from the TOPIST database to illustrate the scientific benefit of improving and expanding the topside ionospheric Ne(h) database. The profile improvements will be based on improvements in the TOPIST software motivated by direct comparisons between TOPIST profiles and profiles produced by manual scaling in the early days of the ISIS program. The database expansion will be based on new software designed to overcome limitations in the original digital topside ionogram database caused by difficulties encountered during the analog-to-digital conversion process in the detection of the ionogram frame sync pulse and/or the frequency markers. This improved and expanded TOPIST topside Ne(h) database will greatly enhance investigations into both short- and long-term ionospheric changes, e.g., the observed topside ionospheric responses to magnetic storms, induced by interplanetary magnetic clouds, and solar cycle variations, respectively.

  2. Diagnosis of chronic active hepatitis in a miniature schnauzer.

    Science.gov (United States)

    Hendrix, Alana D

    2004-09-01

    A 12-year-old male castrated miniature schnauzer was presented with a history of abdominal distension. Serum biochemical analysis and abdominal ultrasonography indicated hepatic disease. A wedge biopsy provided a diagnosis of chronic active hepatitis. A therapeutic regime was initiated to improve the quality of life and slow the progression of this disease is described.

  3. Diagnosis of chronic active hepatitis in a miniature schnauzer

    OpenAIRE

    Hendrix, Alana D.

    2004-01-01

    A 12-year-old male castrated miniature schnauzer was presented with a history of abdominal distension. Serum biochemical analysis and abdominal ultrasonography indicated hepatic disease. A wedge biopsy provided a diagnosis of chronic active hepatitis. A therapeutic regime was initiated to improve the quality of life and slow the progression of this disease is described.

  4. Fabrication of a miniature diamond grinding tool using a hybrid process of micro-EDM and co-deposition

    International Nuclear Information System (INIS)

    Chen, Shun-Tong; Lai, Yun-Cheng; Liu, Ching-Chang

    2008-01-01

    A novel miniature diamond grinding tool usable for the precise micro-grinding of miniature parts is presented. A hybrid process that combines 'micro-EDM' with 'precision co-deposition' is proposed. The metal substrate is micro-EDMed to a 50 µm diameter and micro diamonds with 0–2 µm grains are 'electroformed' on the substrate surface, producing a miniature multilayered grinding tool. Nickel and diamond act as binders and cutters, respectively. A partition plate with an array of drilled holes is designed to ensure good convection in the electroforming solution. The dispersion of diamond grains and displacement of nickel ions are noticeably improved. A miniature funnel mould enables the diamond grains to converge towards the cathode to increase their deposition probability on the substrate, thereby improving their distribution on the substrate surface. A micro ZrO 2 ceramic ferrule is finely ground by the developed grinding tool and then yields a surface roughness of R a = 0.085 µm. The proposed approach is applied during the final machining process

  5. Detection of cryoglobulins in serum of Caspian miniature horse

    Directory of Open Access Journals (Sweden)

    Atyabi, N,

    2012-06-01

    Full Text Available Blood samples were collected from 20 healthy miniature Caspian horses at 37 °C. Isolation of cryoglobulin was performed based on a standard method in present study. Harvested sera were kept at 4 °C for two hours and then examined for cryoglubolin. Four serum samples containing precipitate Suspicious of containing cryoglobulin were selected. Subsequently serum protein electrophoresis was performed on normal serum samples and also on four serum samples containing precipitates using an automated electrophoresis system on cellulose acetate strips. In addition Ig isotypes detection (IgG, IgM and IgA was performed on both precipitates and serum containing precipitates using single radio immunediffusion method (SRID. A narrow-based peak on gamma region of precipitate acetate cellulose strips was observed. Precipitate concentrations were strikingly higher than normal concentration of serum immuneglobulins. It can be suggested that cryoglobulin concentration in a proportion of Caspian miniature horse is higher than other equides may be in relation with animal susceptibility to neoplasias such as lymphoma and leukemia.

  6. Miniaturized Optical Tweezers Through Fiber-End Microfabrication

    KAUST Repository

    Liberale, Carlo; Cojoc, Gheorghe; Rajamanickam, Vijayakumar; Ferrara, Lorenzo; Bragheri, Francesca; Minzioni, Paolo; Perozziello, Gerardo; Candeloro, Patrizio; Cristiani, Ilaria; Di Fabrizio, Enzo M.

    2014-01-01

    Optical tweezers represent a powerful tool for a variety of applications both in biology and in physics, and their miniaturization and full integration is of great interest so as to reduce size (towards portable systems), and to minimize the required intervention from the operator. Optical fibers represent a natural solution to achieve this goal, and here we review the realization of single-fiber optical tweezers able to create a purely optical three-dimensional trap. © Springer International Publishing Switzerland 2015.

  7. Miniaturized Optical Tweezers Through Fiber-End Microfabrication

    KAUST Repository

    Liberale, Carlo

    2014-07-30

    Optical tweezers represent a powerful tool for a variety of applications both in biology and in physics, and their miniaturization and full integration is of great interest so as to reduce size (towards portable systems), and to minimize the required intervention from the operator. Optical fibers represent a natural solution to achieve this goal, and here we review the realization of single-fiber optical tweezers able to create a purely optical three-dimensional trap. © Springer International Publishing Switzerland 2015.

  8. Calcification of the intervertebral discs and curvature of the radius and ulna: A radiographic survey of Finnish miniature dachshunds

    International Nuclear Information System (INIS)

    Lappalainen, A.; Norrgaard, M.; Alm, K.; Snellman, M.; Laitinen, O.

    2001-01-01

    The vertebral column of 124 randomly selected miniature dachshunds, representing 4.5% of the population registered by the Finnish Kennel Club during the years 1988 to 1996, were radiographed. The front legs were also radiographed in order to evaluate the curvature of the radius and ulna. Calcified discs were found in 75.9% of the longhaired miniature dachshunds and in 86.7% of the wirehaired ones. The occurrence of signs associated with IDD was 16.5% in longhaired and 15.6% in wirehaired miniature dachshunds. The occurrence of signs of IDD in dogs with calcified discs was 20.0% and 17.9% in longhaired and wirehaired miniature dachshunds, respectively. In dogs without calcifications only one dog showed signs of IDD. The curvature of the radius and the ulna did not differ between the dogs with signs of IDD and the healthy ones, or between the dogs with and without intervertebral calcifications. Our results indicate that radiographic eradication based on the presence of intervertebral calcifications is not suitable for breeding purposes for the Finnish miniature dachshund population because the percentage of dogs without calcifications is small

  9. Miniature Bioprocess Array: A Platform for Quantitative Physiology and Bioprocess Optimization

    National Research Council Canada - National Science Library

    Keasling, Jay

    2002-01-01

    .... The miniature bioprocess array is based on an array of 150-microliters wells, each one of which incorporates MEMS for the closed-loop control of cell culture parameters such as temperature, pH, and dissolved oxygen...

  10. Development of a novel miniature detonation-driven shock tube assembly that uses in situ generated oxyhydrogen mixture

    International Nuclear Information System (INIS)

    Janardhanraj, S.; Jagadeesh, G.

    2016-01-01

    A novel concept to generate miniature shockwaves in a safe, repeatable, and controllable manner in laboratory confinements using an in situ oxyhydrogen generator has been proposed and demonstrated. This method proves to be more advantageous than existing methods because there is flexibility to vary strength of the shockwave, there is no need for storage of high pressure gases, and there is minimal waste disposal. The required amount of oxyhydrogen mixture is generated using alkaline electrolysis that produces hydrogen and oxygen gases in stoichiometric quantity. The rate of oxyhydrogen mixture production for the newly designed oxyhydrogen generator is found to be around 8 ml/s experimentally. The oxyhydrogen generator is connected to the driver section of a specially designed 10 mm square miniature shock tube assembly. A numerical code that uses CANTERA software package is used to predict the properties of the driver gas in the miniature shock tube. This prediction along with the 1-D shock tube theory is used to calculate the properties of the generated shockwave and matches reasonably well with the experimentally obtained values for oxyhydrogen mixture fill pressures less than 2.5 bars. The miniature shock tube employs a modified tri-clover clamp assembly to facilitate quick changing of diaphragm and replaces the more cumbersome nut and bolt system of fastening components. The versatile nature of oxyhydrogen detonation-driven miniature shock tube opens up new horizons for shockwave-assisted interdisciplinary applications.

  11. Development of a novel miniature detonation-driven shock tube assembly that uses in situ generated oxyhydrogen mixture

    Energy Technology Data Exchange (ETDEWEB)

    Janardhanraj, S.; Jagadeesh, G., E-mail: jaggie@aero.iisc.ernet.in [Department of Aerospace Engineering, Indian Institute of Science, Bangalore 560012 (India)

    2016-08-15

    A novel concept to generate miniature shockwaves in a safe, repeatable, and controllable manner in laboratory confinements using an in situ oxyhydrogen generator has been proposed and demonstrated. This method proves to be more advantageous than existing methods because there is flexibility to vary strength of the shockwave, there is no need for storage of high pressure gases, and there is minimal waste disposal. The required amount of oxyhydrogen mixture is generated using alkaline electrolysis that produces hydrogen and oxygen gases in stoichiometric quantity. The rate of oxyhydrogen mixture production for the newly designed oxyhydrogen generator is found to be around 8 ml/s experimentally. The oxyhydrogen generator is connected to the driver section of a specially designed 10 mm square miniature shock tube assembly. A numerical code that uses CANTERA software package is used to predict the properties of the driver gas in the miniature shock tube. This prediction along with the 1-D shock tube theory is used to calculate the properties of the generated shockwave and matches reasonably well with the experimentally obtained values for oxyhydrogen mixture fill pressures less than 2.5 bars. The miniature shock tube employs a modified tri-clover clamp assembly to facilitate quick changing of diaphragm and replaces the more cumbersome nut and bolt system of fastening components. The versatile nature of oxyhydrogen detonation-driven miniature shock tube opens up new horizons for shockwave-assisted interdisciplinary applications.

  12. Verification of a CT scanner using a miniature step gauge

    DEFF Research Database (Denmark)

    Cantatore, Angela; Andreasen, J.L.; Carmignato, S.

    2011-01-01

    The work deals with performance verification of a CT scanner using a 42mm miniature replica step gauge developed for optical scanner verification. Errors quantification and optimization of CT system set-up in terms of resolution and measurement accuracy are fundamental for use of CT scanning...

  13. Model-based tracking of miniaturized grippers using particle swarm optimization

    NARCIS (Netherlands)

    Scheggi, Stefano; Yoon, ChangKyu; Gracias, David H.; Misra, Sarthak

    2016-01-01

    Micro-sized agents can benefit robotic minimally invasive surgery since they can be inserted into the human body and use natural pathways such as arteries and veins or the gastrointestinal tract, to reach their target for drug delivery or diagnosis. Recently, miniaturized agents with shape-changing

  14. Biosensing with Paper-Based Miniaturized Printed Electrodes–A Modern Trend

    Directory of Open Access Journals (Sweden)

    Célia M. Silveira

    2016-09-01

    Full Text Available From the bench-mark work on microfluidics from the Whitesides’s group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors.

  15. Biosensing with Paper-Based Miniaturized Printed Electrodes–A Modern Trend

    Science.gov (United States)

    Silveira, Célia M.; Monteiro, Tiago; Almeida, Maria Gabriela

    2016-01-01

    From the bench-mark work on microfluidics from the Whitesides’s group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors. PMID:27690119

  16. Biosensing with Paper-Based Miniaturized Printed Electrodes-A Modern Trend.

    Science.gov (United States)

    Silveira, Célia M; Monteiro, Tiago; Almeida, Maria Gabriela

    2016-09-28

    From the bench-mark work on microfluidics from the Whitesides's group in 2007, paper technology has experienced significant growth, particularly regarding applications in biomedical research and clinical diagnostics. Besides the structural properties supporting microfluidics, other advantageous features of paper materials, including their versatility, disposability and low cost, show off the great potential for the development of advanced and eco-friendly analytical tools. Consequently, paper was quickly employed in the field of electrochemical sensors, being an ideal material for producing custom, tailored and miniaturized devices. Stencil-, inkjet-, or screen-printing are the preferential techniques for electrode manufacturing. Not surprisingly, we witnessed a rapid increase in the number of publications on paper based screen-printed sensors at the turn of the past decade. Among the sensing strategies, various biosensors, coupling electrochemical detectors with biomolecules, have been proposed. This work provides a critical review and a discussion on the future progress of paper technology in the context of miniaturized printed electrochemical biosensors.

  17. Telemetry system for monitoring the ECG for patients with high cardiovascular risk. Main design requirements and technical solutions

    International Nuclear Information System (INIS)

    Rodriguez, J; Meissimilly, G; Berovides, JD

    2005-01-01

    In this paper the main design requirements concerning the setting up of a telemetry ECG monitoring system are presented. The design's most important technical solutions as well as some details are also discussed. This system is intended to provide skilled medical assistance during the cardiac rehabilitation of both asymptomatic and high risk coronary patients

  18. A lightweight telemetry system for recording neuronal activity in freely behaving small animals

    NARCIS (Netherlands)

    Schregardus, D.S.; Pieneman, A.W.; ter Maat, A.; Brouwer, T.J.F.; Gahr, M.L.

    2006-01-01

    A miniature lightweight radio telemetric device is described which is shown to be suitable for recording neuronal activity in freely behaving animals. Its size (12 × 5 × 8 mm) and weight (1.0-1.1 g with batteries, 0.4-0.5 g without) make the device particularly suitable for recording neuronal units

  19. Effect of weight and frontal area of external telemetry packages on the kinematics, activity levels and swimming performance of small-bodied sharks.

    Science.gov (United States)

    Bouyoucos, I A; Suski, C D; Mandelman, J W; Brooks, E J

    2017-05-01

    This study sought to observe the effects of submerged weight and frontal cross-sectional area of external telemetry packages on the kinematics, activity levels and swimming performance of small-bodied juvenile sharks, using lemon sharks Negaprion brevirostris (60-80 cm total length, L T ) as a model species. Juveniles were observed free-swimming in a mesocosm untagged and with small and large external accelerometer packages that increased frontal cross-sectional area of the animals and their submerged weight. Despite adhering to widely used standards for tag mass, the presence of an external telemetry package altered swimming kinematics, activity levels and swimming performance of juvenile N. brevirostris relative to untagged individuals, suggesting that tag mass is not a suitable standalone metric of device suitability. Changes in swimming performance could not be detected from tail-beat frequency, which suggests that tail-beat frequency is an unsuitable standalone metric of swimming performance for small N. brevirostris. Lastly, sharks experienced treatment-specific changes in activity level and swimming kinematics from morning to afternoon observation. Therefore, the presence of external telemetry packages altered the kinematics, activity levels and swimming performance of small young-of-the-year N. brevirostris and these data may therefore be relevant to other similar-sized juveniles of other shark species. © 2017 The Fisheries Society of the British Isles.

  20. Moessbauer study of miniature vessels from the Sican burial site of Huaca Loro

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes, G., E-mail: gabriela.cervantes@pucp.pe [Pontificia Universidad Catolica del Peru (Peru); Shimada, I. [Southern Illinois University (United States); Haeusler, W.; Wagner, U.; Wagner, F. E. [Technische Universitaet Muenchen, Physik-Department E15 (Germany)

    2011-11-15

    Small handmade ceramic vessels are often found in large quantities in late pre-hispanic elite tombs on the north coast of Peru. These miniature vessels are of poor artistic and technologic qualities compared with other offerings found in tombs and have not received much attention. Our hypothesis is that these miniatures were made hastily by non-elite funeral attendants, which resulted in the observed formal and material variability. Here we report on the results of a systematic archaeological analysis of the shape and of archaeometric analyses by Moessbauer spectroscopy and XRD of the firing conditions of such vessels that were conducted to test the above hypothesis.

  1. Miniature solid-state gas compressor

    Science.gov (United States)

    Lawless, W.N.; Cross, L.E.; Steyert, W.A.

    1985-05-07

    A miniature apparatus for compressing gases is disclosed in which an elastomer disposed between two opposing electrostrictive or piezoelectric ceramic blocks, or between a single electrostrictive or piezoelectric ceramic block and a rigid surface, is caused to extrude into or recede from a channel defined adjacent to the elastomer in response to application or removal of an electric field from the blocks. Individual cells of blocks and elastomer are connected to effect a gas compression by peristaltic activation of the individual cells. The apparatus is self-valving in that the first and last cells operate as inlet and outlet valves, respectively. Preferred electrostrictive and piezoelectric ceramic materials are disclosed, and an alternative, non-peristaltic embodiment of the apparatus is described. 9 figs.

  2. High-Frequency Flush Mounted Miniature LOX Fiber-Optic Pressure Sensor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Luna Innovations is teaming with the University of Alabama, Huntsville, to develop a miniature flush-mounted fiber-optic pressure sensor that will allow accurate,...

  3. Analytical and Finite Element Modeling of Nanomembranes for Miniaturized, Continuous Hemodialysis

    Directory of Open Access Journals (Sweden)

    Tucker Burgin

    2015-12-01

    Full Text Available Hemodialysis involves large, periodic treatment doses using large-area membranes. If the permeability of dialysis membranes could be increased, it would reduce the necessary dialyzer size and could enable a wearable device that administers a continuous, low dose treatment of chronic kidney disease. This paper explores the application of ultrathin silicon membranes to this purpose, by way of analytical and finite element models of diffusive and convective transport of plasma solutes during hemodialysis, which we show to be predictive of experimental results. A proof-of-concept miniature nanomembrane dialyzer design is then proposed and analytically predicted to clear uremic toxins at near-ideal levels, as measured by several markers of dialysis adequacy. This work suggests the feasibility of miniature nanomembrane-based dialyzers that achieve therapeutic levels of uremic toxin clearance for patients with kidney failure.

  4. The effect of gamma radiation on the stability of miniature reference electrodes

    International Nuclear Information System (INIS)

    Galuszka-Muga, B.; Muga, M.L.; Hanrahan, R.J.

    2006-01-01

    The design and fabrication of four types of miniature reference electrodes and their long term stability in a radiation field are described. Miniature versions of a saturated calomel electrode (MSCE), a silver/silver chloride electrode (MAG), a tungsten/tungsten oxide (MWO) and a copper/copper ion (MCU) electrode were tested in a 10 kGy/h (1 Mrad/h) radiation field for up to 30 days total at 25 and 40 o C. The latter two (MWO and MCU) varied appreciably over time periods of several hours whereas the former two (MSCE and MAG) varied less than 1 mV over periods of 6-8 h and are deemed suitable as reference electrodes for corrosion studies of systems immersed in a radiation field at elevated temperature

  5. DIGITAL PRESERVATION OF ANCIENT MAYA CAVE ARCHITECTURE: RECENT FIELD EFFORTS IN QUINTANA ROO, MEXICO

    Directory of Open Access Journals (Sweden)

    D. Rissolo

    2017-08-01

    Full Text Available The presence of ancient Maya shrines in caves serves as unequivocal evidence for the ritual appropriation of these subterranean spaces and their significance with respect to Maya religious practice. Detailed study of the miniature masonry temples and altar features in the caves of Quintana Roo, Mexico reveals a strong stylistic and likely functional correspondence between these structures and their terrestrial counterparts at Postclassic sites. The Proyecto Arquitectura Subterranea de Quintana Roo (coordinated by the Center of Interdisciplinary Science for Art, Architecture, and Archaeology, or CISA3, at the University of California, San Diego and in collaboration with the Instituto Nacional de Antropologia e Historia in Mexico is conducting a survey and program of digital documentation of both the pristine and impacted cave shrines of the region. Once an area is developed and populated, and access is opened to caves containing ancient architectural features, they are soon vandalized – often resulting in the complete obliteration of these rare miniature buildings and their diagnostic architectural elements. This emergent situation necessitates the use of rapid reality-capture tools; however, the physical challenges of working in caves requires researchers of adapt increasingly common architectural documentation methodologies to more adverse field conditions.

  6. Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

    Science.gov (United States)

    Wan, Hao; Yin, Heyu; Lin, Lu; Zeng, Xiangqun; Mason, Andrew J

    2018-02-01

    The growing impact of airborne pollutants and explosive gases on human health and occupational safety has escalated the demand of sensors to monitor hazardous gases. This paper presents a new miniaturized planar electrochemical gas sensor for rapid measurement of multiple gaseous hazards. The gas sensor features a porous polytetrafluoroethylene substrate that enables fast gas diffusion and room temperature ionic liquid as the electrolyte. Metal sputtering was utilized for platinum electrodes fabrication to enhance adhesion between the electrodes and the substrate. Together with carefully selected electrochemical methods, the miniaturized gas sensor is capable of measuring multiple gases including oxygen, methane, ozone and sulfur dioxide that are important to human health and safety. Compared to its manually-assembled Clark-cell predecessor, this sensor provides better sensitivity, linearity and repeatability, as validated for oxygen monitoring. With solid performance, fast response and miniaturized size, this sensor is promising for deployment in wearable devices for real-time point-of-exposure gas pollutant monitoring.

  7. Ballistic tongue projection in a miniaturized salamander.

    Science.gov (United States)

    Deban, Stephen M; Bloom, Segall V

    2018-05-20

    Miniaturization of body size is often accompanied by peculiarities in morphology that can have functional consequences. We examined the feeding behavior and morphology of the miniaturized plethodontid salamander Thorius, one of the smallest vertebrates, to determine if its performance and biomechanics differ from those of its larger relatives. High-speed imaging and dynamics analysis of feeding at a range of temperatures show that tongue projection in Thorius macdougalli is ballistic and achieves accelerations of up to 600 G with low thermal sensitivity, indicating that tongue projection is powered by an elastic-recoil mechanism. Preceding ballistic projection is an unusual preparatory phase of tongue protrusion, which, like tongue retraction, shows lower performance and higher thermal sensitivity that are indicative of movement being powered directly by muscle shortening. The variability of tongue-projection kinematics and dynamics is comparable to larger ballistic-tongued plethodontids and reveals that Thorius is capable of modulating its tongue movements in response to prey distance. Morphological examination revealed that T. macdougalli possesses a reduced number of myofibers in the tongue muscles, a large projector muscle mass relative to tongue mass, and an unusual folding of the tongue skeleton, compared with larger relatives. Nonetheless, T. macdougalli retains the elaborated collagen aponeuroses in the projector muscle that store elastic energy and a tongue skeleton that is free of direct myofiber insertion, two features that appear to be essential for ballistic tongue projection in salamanders. © 2018 Wiley Periodicals, Inc.

  8. Capillary filling of miniaturized sources for electrospray mass spectrometry

    International Nuclear Information System (INIS)

    Arscott, Steve; Gaudet, Matthieu; Brinkmann, Martin; Ashcroft, Alison E; Blossey, Ralf

    2006-01-01

    Capillary slot-based emitter tips are a novel tool for use in electrospray ionization-mass spectrometry of large biomolecules. We have performed a combined theoretical and experimental study of capillary filling in micron-sized slots with the aim of developing a rational design procedure for miniaturized electrospray sources, ultimately enabling the integration of ESI into laboratory-on-a-chip devices

  9. Release of fission products from miniature fuel plates at elevated temperature

    International Nuclear Information System (INIS)

    Posey, J.C.

    1982-01-01

    Three miniature fuel plates were tested at progressively higher temperatures. A U 3 Si plated blistered and released fission gases at 500 0 C. Two U 3 O 8 filled plates blistered and released fission gases at 550 0 C

  10. Tracking animals in freshwater with electronic tags: past, present and future

    Science.gov (United States)

    Cooke, Steven J.; Midwood, Jonathan D.; Thiem, Jason D.; Klimley, Peter; Lucas, Martyn C.; Thorstad, Eva B.; Eiler, John; Holbrook, Chris; Ebner, Brendan C.

    2013-01-01

    Considerable technical developments over the past half century have enabled widespread application of electronic tags to the study of animals in the wild, including in freshwater environments. We review the constraints associated with freshwater telemetry and biologging and the technical developments relevant to their use. Technical constraints for tracking animals are often influenced by the characteristics of the animals being studied and the environment they inhabit. Collectively, they influence which and how technologies can be used and their relative effectiveness. Although radio telemetry has historically been the most commonly used technology in freshwater, passive integrated transponder (PIT) technology, acoustic telemetry and biologgers are becoming more popular. Most telemetry studies have focused on fish, although an increasing number have focused on other taxa, such as turtles, crustaceans and molluscs. Key technical developments for freshwater systems include: miniaturization of tags for tracking small-size life stages and species, fixed stations and coded tags for tracking large samples of animals over long distances and large temporal scales, inexpensive PIT systems that enable mass tagging to yield population- and community-level relevant sample sizes, incorporation of sensors into electronic tags, validation of tag attachment procedures with a focus on maintaining animal welfare, incorporation of different techniques (for example, genetics, stable isotopes) and peripheral technologies (for example, geographic information systems, hydroacoustics), development of novel analytical techniques, and extensive international collaboration. Innovations are still needed in tag miniaturization, data analysis and visualization, and in tracking animals over larger spatial scales (for example, pelagic areas of lakes) and in challenging environments (for example, large dynamic floodplain systems, under ice). There seems to be a particular need for adapting

  11. Digital microfluidics: A promising technique for biochemical applications

    Science.gov (United States)

    Wang, He; Chen, Liguo; Sun, Lining

    2017-12-01

    Digital microfluidics (DMF) is a versatile microfluidics technology that has significant application potential in the areas of automation and miniaturization. In DMF, discrete droplets containing samples and reagents are controlled to implement a series of operations via electrowetting-on-dielectric. This process works by applying electrical potentials to an array of electrodes coated with a hydrophobic dielectric layer. Unlike microchannels, DMF facilitates precise control over multiple reaction processes without using complex pump, microvalve, and tubing networks. DMF also presents other distinct features, such as portability, less sample consumption, shorter chemical reaction time, flexibility, and easier combination with other technology types. Due to its unique advantages, DMF has been applied to a broad range of fields (e.g., chemistry, biology, medicine, and environment). This study reviews the basic principles of droplet actuation, configuration design, and fabrication of the DMF device, as well as discusses the latest progress in DMF from the biochemistry perspective.

  12. Flame-in-gas-shield and miniature diffusion flame hydride atomizers for atomic fluorescence spectrometry: optimization and comparison

    International Nuclear Information System (INIS)

    Marschner, Karel; Musil, Stanislav; Dědina, Jiří

    2015-01-01

    A detailed optimization of relevant experimental parameters of two hydride atomizers for atomic fluorescence spectrometry: flame-in-gas-shield atomizer with a two-channel shielding unit and a standard atomizer for atomic fluorescence spectrometry, miniature diffusion flame, was performed. Arsine, generated by the reaction with NaBH 4 in a flow injection arrangement, was chosen as the model hydride. Analytical characteristics of both the atomizers (sensitivity, noise, limits of detection) were compared. Under optimum conditions sensitivity obtained with flame-in-gas-shield atomizer was approximately twice higher than with miniature diffusion flame. The additional advantage of flame-in-gas-shield atomizer is significantly lower flame emission resulting in a better signal to noise ratio. The resulting arsenic limits of detection for miniature diffusion flame and flame-in-gas-shield atomizer were 3.8 ng l −1 and 1.0 ng l −1 , respectively. - Highlights: • We optimized and compared two hydride atomizers for atomic fluorescence spectrometry. • Miniature diffusion flame and flame-in-gas-shield atomizer were optimized. • The limit of detection for arsenic was 1.0 ng l −1

  13. Flame-in-gas-shield and miniature diffusion flame hydride atomizers for atomic fluorescence spectrometry: optimization and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Marschner, Karel, E-mail: karel.marschner@biomed.cas.cz [Institute of Analytical Chemistry of the ASCR, v. v. i., Veveří 97, 602 00 Brno (Czech Republic); Charles University in Prague, Faculty of Science, Department of Analytical Chemistry, Albertov 8, 128 43 Prague (Czech Republic); Musil, Stanislav; Dědina, Jiří [Institute of Analytical Chemistry of the ASCR, v. v. i., Veveří 97, 602 00 Brno (Czech Republic)

    2015-07-01

    A detailed optimization of relevant experimental parameters of two hydride atomizers for atomic fluorescence spectrometry: flame-in-gas-shield atomizer with a two-channel shielding unit and a standard atomizer for atomic fluorescence spectrometry, miniature diffusion flame, was performed. Arsine, generated by the reaction with NaBH{sub 4} in a flow injection arrangement, was chosen as the model hydride. Analytical characteristics of both the atomizers (sensitivity, noise, limits of detection) were compared. Under optimum conditions sensitivity obtained with flame-in-gas-shield atomizer was approximately twice higher than with miniature diffusion flame. The additional advantage of flame-in-gas-shield atomizer is significantly lower flame emission resulting in a better signal to noise ratio. The resulting arsenic limits of detection for miniature diffusion flame and flame-in-gas-shield atomizer were 3.8 ng l{sup −1} and 1.0 ng l{sup −1}, respectively. - Highlights: • We optimized and compared two hydride atomizers for atomic fluorescence spectrometry. • Miniature diffusion flame and flame-in-gas-shield atomizer were optimized. • The limit of detection for arsenic was 1.0 ng l{sup −1}.

  14. Miniature Ground Penetrating Radar, CRUX GPR

    Science.gov (United States)

    Kim, Soon Sam; Carnes, Steven R.; Haldemann, Albert F.; Ulmer, Christopher T.; Ng, Eddie; Arcone, Steven A.

    2006-01-01

    Under NASA instrument development programs (PIDDP 2000-2002, MIPD 2003-2005, ESR and T, 2005) we have been developing miniature ground penetrating radars (GPR) for use in mapping subsurface stratigraphy from planetary rovers for Mars and lunar applications. The Mars GPR is for deeper penetration (up to 50 m depth) into the Martian subsurface at moderate resolution (0.5 m) for a geological characterization. As a part of the CRUX (Construction and Resource Utilization Explorer) instrument suite, the CRUX GPR is optimized for a lunar prospecting application. It will have shallower penetration (5 m depth) with higher resolution (10 cm) for construction operations including ISRU (in-situ resource utilization).

  15. The laboratory test rig with miniature jet engine to research aviation fuels combustion process

    Directory of Open Access Journals (Sweden)

    Gawron Bartosz

    2015-12-01

    Full Text Available This article presents laboratory test rig with a miniature turbojet engine (MiniJETRig – Miniature Jet Engine Test Rig, that was built in the Air Force Institute of Technology. The test rig has been developed for research and development works aimed at modelling and investigating processes and phenomena occurring in full scale jet engines. In the article construction of a test rig is described, with a brief discussion on the functionality of each of its main components. Additionally examples of measurement results obtained during the realization of the initial tests have been included, presenting the capabilities of the test rig.

  16. Fabrication of applicator system of miniature X-ray tube based on carbon nanotubes for a skin cancer therapy

    International Nuclear Information System (INIS)

    Park, Han Beom; Kim, Hyun Jin; Lee, Ju Hyuk; Ha, Jun Mok; Cho, Sung Oh

    2016-01-01

    A miniature X-ray tube is a small X-ray generation device generally with a diameter of less than 10 mm. Because of the feasible installation in a spatially constrained area and the possibility of electrical on/off control, miniature X-ray tubes can be widely used for nondestructive X-ray radiography, hand held X-ray spectrometers, electric brachytherapy, and interstitial or intracavitary radiation therapy or imaging with the substitution of radioactive isotopes. Miniature X-ray tubes have been developed mostly using thermionic electron sources or secondary X-ray emission. The X-ray tube show excellent field emission properties and good X-ray spectrum. Also, the flattening filter was made to irradiate uniformly. The X-ray dose radial uniformities between installed flattening filter and non-installed flattening filter were measured. When flattening filter is equipped, X-ray uniformity was improved from higher than 20% to lower than 10%. As a result, the fabricated applicator system of the miniature X-ray tube using optimized flattening filter exhibited fairly excellent properties

  17. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  18. High power VCSELs for miniature optical sensors

    Science.gov (United States)

    Geske, Jon; Wang, Chad; MacDougal, Michael; Stahl, Ron; Follman, David; Garrett, Henry; Meyrath, Todd; Snyder, Don; Golden, Eric; Wagener, Jeff; Foley, Jason

    2010-02-01

    Recent advances in Vertical-cavity Surface-emitting Laser (VCSEL) efficiency and packaging have opened up alternative applications for VCSELs that leverage their inherent advantages over light emitting diodes and edge-emitting lasers (EELs), such as low-divergence symmetric emission, wavelength stability, and inherent 2-D array fabrication. Improvements in reproducible highly efficient VCSELs have allowed VCSELs to be considered for high power and high brightness applications. In this talk, Aerius will discuss recent advances with Aerius' VCSELs and application of these VCSELs to miniature optical sensors such as rangefinders and illuminators.

  19. Dimensional and Structural Control of Silica Aerogel Membranes for Miniaturized Motionless Gas Pumps.

    Science.gov (United States)

    Zhao, Shanyu; Jiang, Bo; Maeder, Thomas; Muralt, Paul; Kim, Nayoung; Matam, Santhosh Kumar; Jeong, Eunho; Han, Yen-Lin; Koebel, Matthias M

    2015-08-26

    With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias. However, the development of highly miniaturized active membrane materials with tailored porosity and optimized pumping performance remains a major challenge. Here we report a systematic study on the manufacturing of aerogel membranes using an optimized, minimal-shrinkage sol-gel process, leading to low thermal conductivity and high air conductance. This combination of properties results in superior performance for miniaturized thermomolecular air pump applications. The engineering of such aerogel membranes, which implies pore structure control and chemical surface modification, requires both chemical processing know-how and a detailed understanding of the influence of the material properties on the spatial flow rate density. Optimal pumping performance was found for devices with integrated membranes with a density of 0.062 g cm(-3) and an average pore size of 142.0 nm. Benchmarking of such low-density hydrophobic active aerogel membranes gave an air flow rate density of 3.85 sccm·cm(-2) at an operating temperature of 400 °C. Such a silica aerogel membrane based system has shown more than 50% higher pumping performance when compared to conventional transpiration pump membrane materials as well as the ability to withstand higher operating temperatures (up to 440 °C). This study highlights new perspectives for the development of miniaturized thermal transpiration air pumps while offering insights into the fundamentals of molecular pumping in

  20. Scaling laws for free piston Stirling engine design: Benefits and challenges of miniaturization

    International Nuclear Information System (INIS)

    Formosa, Fabien; Fréchette, Luc G.

    2013-01-01

    This work explores the scaling effects for FPSE (free piston Stirling engines), which are known for their simple architecture and potentially high thermodynamic performances. Scaling laws are given and their potential for miniaturization is highlighted. A simple model which allows the design of the geometrical parameters of the heat exchangers, the regenerator and the masses of the pistons is proposed. It is based on the definition of six characteristic dimensionless groups. They are derived from the physics underlying the behavior of the free piston Stirling machine and their relevancy is backed up by comparisons between documented Stirling engines from the literature. Keeping constant values for each group throughout the scaling range theoretically ensures constant performance. The main losses of Stirling engine (heat conduction loss, reheat loss in the regenerator, pressure drop and gas-spring hysteresis) can be expressed as a function of the geometrical and operating parameters. Additionally, the consequences of leakage due to the manufacturing precision of pistons architectures are underlined. From the proposed scaling laws, potential power and efficiency of Stirling cycle engines at a millimeter scale can be anticipated. It appears that the power density increases with miniaturization. It is also shown that the dynamic masses related to the engine size are increased when scaling down and that the gap leakage presents the highest detrimental effects on the efficiency. These results call for dedicated architectures for micro-engines. - Highlights: • Similitude strategy is applied to Stirling engines and allows preliminary design. • New scaling laws are derived. • The power density can be increased with miniaturization. • The gap between the piston and casing is highly detrimental to the performances. • High engine operating pressure is required when miniaturizing