WorldWideScience

Sample records for mini-journal mini-journals replace

  1. Incorporating Inquiry into Upper-Level Homework Assignments: The Mini-Journal

    Science.gov (United States)

    Whittington, A. G.; Speck, A. K.; Witzig, S. B.; Abell, S. K.

    2009-12-01

    The U.S. National Science Education Standards provide guidelines for teaching science through inquiry, where students actively develop their understanding of science by combining scientific knowledge with reasoning and thinking skills. Inquiry activities include reading scientific literature, generating hypotheses, designing and carrying out investigations, interpreting data, and formulating conclusions. Inquiry-based instruction emphasizes questions, evidence, and explanation, the essential features of inquiry. As part of an NSF-funded project, “CUES: Connecting Undergraduates to the Enterprise of Science,” new inquiry-based homework materials were developed for two upper-level classes at the University of Missouri: Geochemistry (required for Geology majors), and Solar System Science (open to seniors and graduate students, co-taught and cross-listed between Geology and Physics & Astronomy). We engage students in inquiry-based learning by presenting homework exercises as “mini-journal” articles that follow the format of a scientific journal article, including a title, authors, abstract, introduction, methods, results, discussion and citations to peer-reviewed literature. The mini-journal provides a scaffold and serves as a springboard for students to develop and carry out their own follow-up investigation. They then present their findings in the form of their own mini-journal. Mini-journals replace traditional homework problem sets with a format that more directly reflects and encourages scientific practice. Students are engaged in inquiry-based homework which encompass doing, thinking, and communicating, while the minijournal allows the instructor to contain lines of inquiry within the limits posed by available resources. In the examples we present, research is conducted via spreadsheet modeling, where the students develop their own spreadsheets. The key differences between the old and new formats include (i) the active participation of the students in

  2. Mini-Journal Inquiry Laboratory: A Case Study in a General Chemistry Kinetics Experiment

    Science.gov (United States)

    Zhao, Ningfeng; Wardeska, Jeffrey G.

    2011-01-01

    The mini-journal curriculum for undergraduate science laboratories mirrors the format of scientific literature and helps students improve their learning through direct scientific practices. The lab embodies the essential features of scientific inquiry and replaces the traditional "cookbook" lab to engage students in active learning. A case study…

  3. Mini-Journals: Incorporating Inquiry, Quantitative Skills and Writing into Homework Assignments for Geochemistry and Planetary Science

    Science.gov (United States)

    Whittington, A. G.; Speck, A.; Witzig, S.

    2011-12-01

    As part of an NSF-funded project, "CUES: Connecting Undergraduates to the Enterprise of Science," new inquiry-based homework materials were developed for two upper-level classes at the University of Missouri: Geochemistry (required for Geology majors, fulfills the computing requirement by having 50% of the grade come from five spreadsheet-based homework assignments), and Solar System Science (open to seniors and graduate students, co-taught and cross-listed between Geology and Physics & Astronomy). Inquiry involves activities where the learner engages in scientifically oriented questions, gives priority to evidence in responding to questions, formulates explanations from evidence, connects explanations to scientific knowledge, and communicates and justifies explanations. We engage students in inquiry-based learning by presenting homework exercises as "mini-journal" articles that follow the format of a scientific journal article, including a title, authors, abstract, introduction, methods, results, discussion and citations to peer-reviewed literature. The mini-journal provides a scaffold and serves as a springboard for students to develop and carry out their own follow-up investigation. They then present their findings in the form of their own mini-journal. Mini-journals replace traditional homework problem sets with a format that more directly reflects and encourages scientific practice. Students are engaged in inquiry-based homework which encompass doing, thinking, and communicating, while the mini-journal allows the instructor to contain lines of inquiry within the limits posed by available resources. In the examples we present, research is conducted via spreadsheet modeling, where the students develop their own spreadsheets. Example assignments from Geochemistry include "Trace Element Partitioning During Mantle Melting and MORB Crystallization" and "Isotopic Investigations of Crustal Evolution in the Midcontinent US". The key differences between the old and new

  4. Incorporating Inquiry into Upper-Level Undergraduate Homework Assignments: The Mini-Journal

    Science.gov (United States)

    Whittington, Alan; Speck, Angela; Witzig, Stephen; Abell, Sandra

    2010-05-01

    -style format. A detailed grading rubric was supplied with the mini-journal, with credit given for formatting, accuracy of calculation, and quality of intepretation and discussion. In the examples we present, research is conducted via spreadsheet modeling, where the students develop their own spreadsheets. The key differences between the old and new formats include (i) the active participation of the students in defining the problem that they will pursue, (ii) the open-ended nature of the inquiry, such that students need to recognize when they have enough information to answer their question, (iii) presentation of results in graphical and tabular formats, and (iv) a written discussion of their findings. Based on detailed student and instructor feedback, our conclusions are: (i) Limited inquiry is achievable in upper-level science homework assignments, and is transferable to other topics and classes (ii) Students experience discomfort on being presented with an open-ended assignment, but like the freedom to define their own homework problem (iii) Students recognize that the reading, writing and critical thinking skills employed in the minijournal format increase their understanding (iv) Students suggest a combination of minijournal and traditional homework formats in this class, or replacing midterm exams with minijournals (v) Student written comments are far more useful than Likert scale responses in assessing instructional techniques and effectiveness

  5. P A Mini

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. P A Mini. Articles written in Bulletin of Materials Science. Volume 36 Issue 4 August 2013 pp 547-551. Composite supercapacitor electrodes made of activated carbon/PEDOT:PSS and activated carbon/doped PEDOT · T S Sonia P A Mini R Nandhini Kalluri Sujith Balakrishnan ...

  6. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment.

    Science.gov (United States)

    Lee, Jin-Hwa; Choo, Hyeran; Kim, Seong-Hun; Chung, Kyu-Rhim; Giannuzzi, Lucille A; Ngan, Peter

    2011-06-01

    When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  7. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  8. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  9. Journal of Biosciences | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Biosciences. LAXMAN S MEENA. Articles written in Journal of Biosciences. Volume 43 Issue 1 March 2018 pp 149-154 Mini-Review. Triacylglycerol: nourishing molecule in endurance of Mycobacterium tuberculosis · PRATAP C MALI LAXMAN S MEENA · More Details Abstract Fulltext PDF.

  10. Journal of Biosciences | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Biosciences. PRATAP C MALI. Articles written in Journal of Biosciences. Volume 43 Issue 1 March 2018 pp 149-154 Mini-Review. Triacylglycerol: nourishing molecule in endurance of Mycobacterium tuberculosis · PRATAP C MALI LAXMAN S MEENA · More Details Abstract Fulltext PDF.

  11. Journal of Biosciences | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Biosciences; Volume 42; Issue 1. Diverse roles of WDR5-RbBP5-ASH2L-DPY30 (WRAD) complex in the functions of the SET1 histone methyltransferase family. AAMIR ALI SHWETA TYAGI. Mini-Review Volume 42 Issue 1 ... Keywords. Cell cycle regulation; SET1 family; transcription; WRAD ...

  12. [Bone remodeling and modeling/mini-modeling.

    Science.gov (United States)

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  13. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [ARIES Collaborative, New York, NY (United States); Podorson, David [ARIES Collaborative, New York, NY (United States); Varshney, Kapil [ARIES Collaborative, New York, NY (United States)

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  14. Resonance journal of science education

    Indian Academy of Sciences (India)

    IAS Admin

    RESONANCE | May 2010. Resonance journal of science education. May 2010 Volume 15 Number 5. On the Measurement of Phase Difference using CROs b. SERIES ARTICLES. 400. Aerobasics – An Introduction to Aeronautics. Mini and Micro Airplanes. S P Govinda Raju. GENERAL ARTICLES. 411. Bird of Passage at ...

  15. Mini implants for definitive prosthodontic treatment: a systematic review.

    Science.gov (United States)

    Bidra, Avinash S; Almas, Khalid

    2013-03-01

    . Insufficient information about failures after the first year makes it difficult to draw conclusions about the medium-term survival of these implants. Currently, there is no evidence for the long-term survival of mini implants. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. Mini-review: The Morphology, Mineralogy and Microbiology of Accumulated Iron Corrosion Products

    Science.gov (United States)

    2014-03-11

    including the morphology, mineralogy , microbiology and the mecha- nisms for formation. Use of descriptive terms to denote specific iron corrosion product...RESPONSIBLE PERSON 19b. TELEPHONE NUMBER (Include area code) 11-03-2014 Journal Article Mini-review: the morphology, mineralogy and microbiology of...oxides/ hydroxides with a preponderance of α-FeOOH (goethite) and accumulation of metals. Bacteria, particularly iron-oxidizing and sulfatereducing

  17. Critical factors for the success of orthodontic mini-implants: a systematic review.

    Science.gov (United States)

    Chen, Yan; Kyung, Hee Moon; Zhao, Wen Ting; Yu, Won Jae

    2009-03-01

    This systematic review was undertaken to discuss factors that affect mini-implants as direct and indirect orthodontic anchorage. The data were collected from electronic databases (Medline [Entrez PubMed], Embase, Web of Science, Cochrane Library, and All Evidence Based Medicine Reviews). Randomized clinical trials, prospective and retrospective clinical studies, and clinical trials concerning the properties, affective factors, and requirements of mini-implants were considered. The titles and abstracts that appeared to fulfill the initial selection criteria were collected by consensus, and the original articles were retrieved and evaluated with a methodologic checklist. A hand search of key orthodontic journals was performed to identify recent unindexed literature. The search strategy resulted in 596 articles. By screening titles and abstracts, 126 articles were identified. After the exclusion criteria were applied, 16 articles remained. The analyzed results of the literature were divided into 2 topics: placement-related and loading-related factors. Mini-implants are effective as anchorage, and their success depends on proper initial mechanical stability and loading quality and quantity.

  18. Replacing the AMOR with the miniDOAS in the ammonia monitoring network in the Netherlands

    NARCIS (Netherlands)

    Berkhout, Augustinus J. C.; Swart, Daan P. J.; Volten, Hester; Gast, Lou F. L.; Haaima, Marty; Verboom, Hans; Stefess, Guus; Hafkenscheid, Theo; Hoogerbrugge, Ronald

    2017-01-01

    In this paper we present the continued development of the miniDOAS, an active differential optical absorption spectroscopy (DOAS) instrument used to measure ammonia concentrations in ambient air. The miniDOAS has been adapted for use in the Dutch National Air Quality Monitoring Network. The miniDOAS

  19. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI).

    Science.gov (United States)

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-05-22

    There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.

  20. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    Science.gov (United States)

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen’s kappa and “observed agreement”. Results There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and “observed agreement” was above 88%. Conclusion The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language. PMID:24886297

  1. Journal of Language, Technology & Entrepreneurship in Africa Vol ...

    African Journals Online (AJOL)

    represented that tranche of age between childhood and adulthood. ... empowering Kenya's street children for integration in national development In Journal of .... In the 1960/70ss, the mini-skirt, the ripples of Black Power movement, the Afro hair ... music recounts social and economic hardships that the Youth face every day.

  2. Return of the mini

    International Nuclear Information System (INIS)

    Ashmore, C.

    2001-01-01

    Partly as a result of the contentious nature of some large hydroelectric schemes, and continuing deregulation on a global scale, the mini hydro systems are enjoying unprecedented growth. This article discusses the reasons for the increase in demand for mini hydro systems, and describes Alstom Power Hydro's new, integrated 'water-to-wire' renewable energy solution which is a modular system which integrates the hydro-turbine, generator and controls to provide a single optimised product called the Mini-Aqua. The Mini-Aqua can be supplied inside a turnkey package including all civil works. The company is also looking to the future with development of its Powerformer technology for smaller-scale, grid-connected applications

  3. Consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo J. Fonseca D'El Rey

    2007-01-01

    Full Text Available CONTEXTO: A fobia social é um grave transtorno de ansiedade que traz incapacitação e sofrimento. OBJETIVOS: Investigar a consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN. MÉTODOS: Foi realizado um estudo da consistência interna do Mini-SPIN em uma amostra de 206 estudantes universitários da cidade de São Paulo, SP. RESULTADOS: A consistência interna do instrumento, analisada pelo coeficiente alfa de Cronbach, foi de 0,81. CONCLUSÕES: Esses achados permitiram concluir que a versão em português do Mini-SPIN exibiu resultados de boa consistência interna, semelhantes aos da versão original em inglês.BACKGROUND: Social phobia is a severe anxiety disorder that brings disability and distress. OBJECTIVES: To investigate the internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN. METHODS: We conducted a study of internal consistency of the Mini-SPIN in a sample of 206 college students of the city of São Paulo, SP. RESULTS: The internal consistency of the instrument, analyzed by Cronbach's alpha coefficient, was 0.81. CONCLUSIONS: These findings suggest that the Portuguese version of the Mini-SPIN has a good internal consistency, similar to those obtained with the original English version.

  4. Graphic software ''MiniG'' for the Mini-6

    International Nuclear Information System (INIS)

    Zen, J.

    1984-06-01

    MiniG is a set of subprograms, written and aimed at being used in Fortran for graphic applications in nuclear physics (histograms or point clouds). It includes three representation modes of axis scales (linear, semi-log and squared root), five types of vectors and numerous graphic symbols for spectra representation with or without notation (circle, cross, arrow, triangle, spiral, etc.). It offers also the possibilities of the software ''Plot-10'' of Tektronix, and accept all the types of graphic terminals of SATD connected to Mini-6 [fr

  5. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    Science.gov (United States)

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  6. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN) Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)

    OpenAIRE

    Gustavo José Fonseca D'El Rey; Cláudia Wilmor Matos

    2009-01-01

    A fobia social (também conhecida como transtorno de ansiedade social) é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN) em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426) de um estudo de prevalência de transtornos de ansieda...

  7. MiniCNT - A Tabletop Stellarator

    Science.gov (United States)

    Dugan, Chris; Pedersen, Thomas; Berkery, John

    2006-10-01

    MiniCNT is a scaled down version of the Columbia Non-Neutral Torus, a stellarator built to study confinement of non-neutral plasmas on magnetic surfaces. MiniCNT is a glass vacuum chamber capable of holding pressures six orders of magnitude below atmospheric pressure. Unlike CNT, in which plasmas are invisible, MiniCNT allows some collisions with neutrals, causing it to glow. Using two twelve-volt car batteries to power four magnetic coils, MiniCNT generates a 0.02 Tesla magnetic field. While CNT, being larger, is obviously more accurate, there are multiple benefits in MiniCNT. First, it is more flexible and can be adjusted to fit many scenarios easily. The car batteries can be switched for other power sources, the coils can be realigned, and the chamber can be pumped to various pressures of various gases. Also, it is visually accessible; while CNT has glass viewing ports and its plasma is dark, MiniCNT is made of glass and its plasma glows, allowing visualization of the magnetic surfaces.

  8. Mini-Cog and Mini-Mental State Examination: agreement in a cross-sectional study with an elderly sample.

    Science.gov (United States)

    Costa, Diogo; Severo, Milton; Fraga, Sílvia; Barros, Henrique

    2012-01-01

    We aimed to compare the Mini-Mental State Examination (MMSE) with the Mini-Cog, measuring agreement in participants' classification, using a general population sample. Cross-sectional evaluation of 609 community dwellers aged ≥60 years was performed by trained interviewers. Cohen's kappa and 95% confidence intervals (CI) were calculated to assess overall agreement, and Cronbach alphas computed to assess reliability. Two-parameter Item Response Theory models (difficulty and discrimination parameters) were used to assess discrimination. Considering MMSE cut-point for scores Mini-Cog's cut-point score Mini-Cog Mini-Cog Mini-Cog's alpha was 0.2776. Co-calibration according to inherent ability is graphically presented. Agreement between scales seems fragile in our sample. The discriminative and reliability analysis suggests a better performance for subsets of the MMSE compared with the Mini-Cog. Usefulness of calibrated scores is discussed. Copyright © 2012 S. Karger AG, Basel.

  9. MiniDraw

    DEFF Research Database (Denmark)

    2018-01-01

    MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010.......MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010....

  10. Mini-grid Policy Tool-kit. Policy and business frameworks for successful mini-grid roll-outs

    International Nuclear Information System (INIS)

    Franz, Michael; Hayek, Niklas; Peterschmidt, Nico; Rohrer, Michael; Kondev, Bozhil; Adib, Rana; Cader, Catherina; Carter, Andrew; George, Peter; Gichungi, Henry; Hankins, Mark; Kappiah, Mahama; Mangwengwende, Simbarashe E.

    2014-01-01

    The Mini-grid Policy Tool-kit is for policy makers to navigate the mini-grid policy design process. It contains information on mini-grid operator models, the economics of mini-grids, and necessary policy and regulation that must be considered for successful implementation. The publication specifically focuses on Africa. Progress on extending the electricity grid in many countries has remained slow because of high costs of gird-extension and limited utility/state budgets for electrification. Mini-grids provide an affordable and cost-effective option to extend needed electricity services. Putting in place the right policy for min-grid deployment requires considerable effort but can yield significant improvement in electricity access rates as examples from Kenya, Senegal and Tanzania illustrate. The tool-kit is available in English, French and Portuguese

  11. Review of mini-clinical evaluation exercise (mini-CEX in a psychiatry clerkship

    Directory of Open Access Journals (Sweden)

    Meresh E

    2018-04-01

    Full Text Available Edwin Meresh,1 David Daniels,2 Aparna Sharma,1 Murali Rao,1 Kaushal Mehta,3 David Schilling1 1Department of Psychiatry and Behavioral Neurosciences, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA; 2Department of Psychiatry, Medstar Georgetown University Hospital, Washington, DC, USA; 3School of Public Health, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL USA Background: Direct observation of medical students with actual patients is important for the assessment of clinical skills including interviewing and counseling skills. This article describes medical students’ experience of mini-clinical evaluation exercise (mini-CEX during their clerkship in consultation psychiatry. Materials and methods: In our center during inpatient consultation psychiatry clerkship, all rotating students are expected to complete one mini-CEX assessment as part of their clinical training. We conducted retrospective analysis of mini-CEX ratings completed from 2013 to 2016. All evaluations took place at inpatient medical setting in patients admitted with medical conditions and psychiatric comorbidities. Results: A total of 113 evaluations were reviewed. The time examiner observed the interaction of a student with the patient was 14.24 minutes (mean, and the time spent in providing feedback to the student was 9.71 minutes. Complexity of problem was rated as low in 0.88% (n=1, moderate in 50.44% (n=57, and high in 48.67% (n=55. Highest ratings were for professionalism, similar to previous reports. Total score calculated by examiner showed no difference by the complexity of the patient; however, we observed a trend in higher counseling score for the high complexity group. Conclusion: Mini-CEX assessment during busy clerkship is feasible with good outcomes. Direct observation of medical trainees with actual patients is important for the assessment of performance-based clinical skills. Hospital psychiatry rotation

  12. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    OpenAIRE

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnos...

  13. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  14. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo José Fonseca D'El Rey

    2009-12-01

    Full Text Available A fobia social (também conhecida como transtorno de ansiedade social é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426 de um estudo de prevalência de transtornos de ansiedade na cidade de Santo André (SP. A versão em português do Mini-SPIN (com escore de 6 pontos, sugerido na versão original em inglês demonstrou uma sensibilidade de 95,0%, especificidade de 80,3%, valor preditivo positivo de 52,8%, valor preditivo negativo de 98,6% e taxa de classificação incorreta de 16,9%. Com escores de 7 pontos, foi observado um aumento na especificidade e no valor preditivo positivo (88,6% e 62,7%, sendo que a sensibilidade e o valor preditivo negativo (84,8% e 96,2% mantiveram-se altos. A versão em português do Mini-SPIN apresentou qualidades psicométricas satisfatórias em termos de validade discriminativa. Neste estudo, o ponto de corte igual a 7 mostrou-se mais adequado para a identificação da fobia social generalizada.Social phobia (also known as social anxiety disorder is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426 of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive

  15. Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement.

    Science.gov (United States)

    Tavakoli, Reza; Leprince, Pascal; Gassmann, Max; Jamshidi, Peiman; Yamani, Nassrin; Amour, Julien; Lebreton, Guillaume

    2018-03-26

    Aortic valve stenosis has become the most prevalent valvular heart disease in developed countries, and is due to the aging of these populations. The incidence of the pathology increases with growing age after 65 years. Conventional surgical aortic valve replacement through median sternotomy has been the gold standard of patient care for symptomatic aortic valve stenosis. However, as the risk profile of patients worsens, other therapeutic strategies have been introduced in an attempt to maintain the excellent results obtained by the established surgical treatment. One of these approaches is represented by transcatheter aortic valve implantation. Although the outcomes of high-risk patients undergoing treatment for symptomatic aortic valve stenosis have improved with transcatheter aortic valve replacement, many patients with this condition remain candidates for surgical aortic valve replacement. In order to reduce the surgical trauma in patients who are candidates for surgical aortic valve replacement, minimally invasive approaches have garnered interest during the past decade. Since the introduction of right anterior thoracotomy for aortic valve replacement in 1993, right anterior mini-thoracotomy and upper hemi-sternotomy have become the predominant incisional approaches among cardiac surgeons performing minimal access aortic valve replacement. Beside the location of the incision, the arterial cannulation site represents the second major landmark of minimal access techniques for aortic valve replacement. The two most frequently used arterial cannulation sites include central aortic and peripheral femoral approaches. With the purpose of reducing surgical trauma in these patients, we have opted for a right anterior mini-thoracotomy approach with a central aortic cannulation site. This protocol describes in detail a technique for minimally invasive aortic valve replacement and provides recommendations for patient selection criteria, including cardiac computer

  16. Spurious RF signals emitted by mini-UAVs

    NARCIS (Netherlands)

    Schleijpen, R.; Voogt, V.; Zwamborn, P.; Oever, J. van den

    2016-01-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to

  17. Psychometric Evaluation of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    Science.gov (United States)

    Duncan, Laura; Georgiades, Kathy; Wang, Li; Van Lieshout, Ryan J; MacMillan, Harriet L; Ferro, Mark A; Lipman, Ellen L; Szatmari, Peter; Bennett, Kathryn; Kata, Anna; Janus, Magdalena; Boyle, Michael H

    2017-12-04

    The goals of the study were to examine test-retest reliability, informant agreement and convergent and discriminant validity of nine DSM-IV-TR psychiatric disorders classified by parent and youth versions of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID). Using samples drawn from the general population and child mental health outpatient clinics, 283 youth aged 9 to 18 years and their parents separately completed the MINI-KID with trained lay interviewers on two occasions 7 to 14 days apart. Test-retest reliability estimates based on kappa (κ) went from 0.33 to 0.79 across disorders, samples and informants. Parent-youth agreement on disorders was low (average κ = 0.20). Confirmatory factor analysis provided evidence supporting convergent and discriminant validity. The MINI-KID disorder classifications yielded estimates of test-retest reliability and validity comparable to other standardized diagnostic interviews in both general population and clinic samples. These findings, in addition to the brevity and low administration cost, make the MINI-KID a good candidate for use in epidemiological research and clinical practice. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. The MiniBooNE Detector

    OpenAIRE

    MiniBooNE Collaboration

    2008-01-01

    The MiniBooNE neutrino detector was designed and built to look for muon-neutrino to electron-neutrino oscillations in the mixing parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  19. A DNA mini-barcode for land plants.

    Science.gov (United States)

    Little, Damon P

    2014-05-01

    Small portions of the barcode region - mini-barcodes - may be used in place of full-length barcodes to overcome DNA degradation for samples with poor DNA preservation. 591,491,286 rbcL mini-barcode primer combinations were electronically evaluated for PCR universality, and two novel highly universal sets of priming sites were identified. Novel and published rbcL mini-barcode primers were evaluated for PCR amplification [determined with a validated electronic simulation (n = 2765) and empirically (n = 188)], Sanger sequence quality [determined empirically (n = 188)], and taxonomic discrimination [determined empirically (n = 30,472)]. PCR amplification for all mini-barcodes, as estimated by validated electronic simulation, was successful for 90.2-99.8% of species. Overall Sanger sequence quality for mini-barcodes was very low - the best mini-barcode tested produced sequences of adequate quality (B20 ≥ 0.5) for 74.5% of samples. The majority of mini-barcodes provide correct identifications of families in excess of 70.1% of the time. Discriminatory power noticeably decreased at lower taxonomic levels. At the species level, the discriminatory power of the best mini-barcode was less than 38.2%. For samples believed to contain DNA from only one species, an investigator should attempt to sequence, in decreasing order of utility and probability of success, mini-barcodes F (rbcL1/rbcLB), D (F52/R193) and K (F517/R604). For samples believed to contain DNA from more than one species, an investigator should amplify and sequence mini-barcode D (F52/R193). © 2013 John Wiley & Sons Ltd.

  20. The MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bartoszek, L.M.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Green, C.; Green, J.A.

    2009-01-01

    The MiniBooNE neutrino detector was designed and built to look for ν μ →ν e oscillations in the (sin 2 2θ,Δm 2 ) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  1. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  2. Design guidelines for mini-roundabouts

    CSIR Research Space (South Africa)

    Emslie, I

    1997-03-01

    Full Text Available Guidelines for Traffic Calming. Concepts and principles relating to the use of mini-roundabouts as a form of intersection control and in the traffic calming context are discussed. Warrants for the implementation of mini-roundabouts and design standards...

  3. MiniBooNE Oscillation Results

    International Nuclear Information System (INIS)

    Djurcic, Zelimir

    2009-01-01

    These proceedings summarize the MiniBooNE ν μ → ν e results, describe the first (bar ν) μ → (bar ν) e result, and current analysis effort with the NuMI neutrinos detected in the miniBooNE detector

  4. MiniGRAIL progress report 2004

    International Nuclear Information System (INIS)

    Waard, A de; Benzaim, Y; Frossati, G; Gottardi, L; Mark, H van der; Flokstra, J; Podt, M; Bassan, M; Minenkov, Y; Moleti, A; Rocchi, A; Fafone, V; Pallottino, G V

    2005-01-01

    The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 μφ 0 Hz -1/2 . The detector was calibrated and the sensitivity curve of MiniGRAIL was determined

  5. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Mini-Sniffer on Lakebed

    Science.gov (United States)

    1974-01-01

    The original Mini-Sniffer on Rogers Dry Lake, adjacent to NASA's Flight Research Center, Edwards AFB. This version of the remotely-piloted vehicle had swept-back wings, tip rudders, nose canards, and an air breathing engine. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  7. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  8. The Individual Features Of Indonesian-Chinese Mini-Novels

    Directory of Open Access Journals (Sweden)

    Ma Feng

    2011-11-01

    Full Text Available This article talks about mini-novels in the new period of Indonesian Chinese Literature. Through the overall developing trend of mini-novels’ corpuses, analyzes the individual creative features: firstly, the humor of Mo Mingmiao’s Mini-novels; secondly, the compassion of Xiao Xing’s Mini-novels; thirdly, Yuan Ni’s emotional sonata of The Lost Key-ring. By combination of themes and techniques of the three mini-novels corpuses, the article focuses on the analysis of three writers’ distinctive writing style.

  9. Mini-Sniffer II in Flight

    Science.gov (United States)

    1976-01-01

    This photograph shows the second Mini-Sniffer undergoing flight testing over Rogers Dry Lake in Edwards, California. This version of the Mini-Sniffer lacked the canard of the original version and had wing tips and tail booms added. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  10. Current Status of the MiniBooNE Experiment

    OpenAIRE

    Ray, H.; collaboration, for the MiniBooNE

    2004-01-01

    MiniBooNE is an experiment designed to refute or confirm the LSND anti-nu_mu -> anti-nu_e oscillation result. MiniBooNE will look for oscillations of nu_mu -> nu_e in a closed-box appearance analysis. MiniBooNE began collecting data in 2002, and is expected to continue data taking through 2005. Current MiniBooNE results are presented.

  11. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burman, Kari [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, Mohit [National Renewable Energy Lab. (NREL), Golden, CO (United States); Esterly, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mutiso, Rose [US Department of Energy, Washington, DC (United States); McGregor, Caroline [US Department of Energy, Washington, DC (United States)

    2016-11-01

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that

  12. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  13. Movimentação de molares inferiores ancorados em mini-parafusos Mandibular molar uprighting, using mini-screw as anchorage

    Directory of Open Access Journals (Sweden)

    Rosana Canteras Di Matteo

    2005-08-01

    Full Text Available Freqüentemente a movimentação ortodôntica exige recursos adicionais de ancoragem. Os mini-parafusos têm-se apresentado como uma possível solução. O propósito deste trabalho foi estabelecer um método para a verticalização de molares inferiores inclinados para mesial, utilizando ancoragem em mini-parafusos colocados na região de linha oblíqüa externa da mandíbula. Foram selecionados três pacientes entre 40 a 48 anos (dois do gênero feminino, um do gênero masculino, com molares inferiores inclinados para mesial e distalmente posicionados às áreas edêntulas. Os pacientes foram tratados ortodonticamente durante um período de 6 a 12 meses, com técnica ortodôntica MD3. Mini-parafusos de titânio foram colocados bilateralmente com anestesia local. Uma incisão sobre a linha oblíqüa externa da mandíbula, medindo aproximadamente 1 cm foi realizada em cada lado, distalmente aos molares inclinados. Após descolamento muco-periosteal, mini-parafusos foram implantados e foram realizadas suturas deixando suas cabeças exteriorizadas. Uma semana após a remoção das suturas, cargas ortodônticas (entre 150 a 200 gramas/força foram aplicadas através de forças elásticas. Verificamos que alguma inflamação foi observada ao redor dos mini-parafusos, mas foi controlada com procedimentos de higienização. O procedimento cirúrgico é simples, podendo ser realizado pelo ortodontista; as formas dimensionais dos mini-parafusos são adequadas e estes são de fácil remoção após uso. Concluímos que o uso de mini-parafusos representa uma alternativa efetiva de ancoragem ortodôntica na verticalização de molares inferiores.Tooth movement frequently requires additional anchorage resources. Mini-screws have been used as a possible solution to this matter. The purpose of this study was to establish a method of mandibular molar uprighting, using mini-screw as anchorage, positioned on the mandibular external oblique line, behind and

  14. Standardization of the Korean version of Mini-Mental Adjustment to Cancer (K-Mini-MAC) scale: factor structure, reliability and validity.

    Science.gov (United States)

    Kang, Jee In; Chung, Hyun Cheol; Kim, Se Joo; Choi, Hye Jin; Ahn, Joong Bae; Jeung, Hei-Cheul; Namkoong, Kee

    2008-06-01

    Mental adjustment and coping affect the physical outcome and survival as well as quality of life in cancer patients. The Mini-Mental Adjustment to Cancer (Mini-MAC) scale is a new refined, economical and reliable self-rating instrument measuring cognitive and behavioral responses to cancer. The aim of this study was to evaluate the psychometric properties of the Mini-MAC in Korean cancer patients. A total of 208 cancer patients recruited from the Yonsei Cancer Center were assessed with the Mini-MAC and the Hospital Anxiety and Depression Scale (HADS). Principal component analysis with varimax rotation for the Korean version of Mini-MAC (K-Mini-MAC) confirmed four factors. Three had psychometric properties similar to Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) of the original Mini-MAC. A novel factor, named Positive Attitude, included items of both Fatalism (FA) and Fighting Spirit (FS) from the original version. The five subscales from the original version (AP, HH, FS, FA and CA) and Positive Attitude had acceptable internal reliabilities in our sample (Cronbach's alpha coefficient 0.50-0.86; correlation coefficient of test-retest 0.68-0.88). For the validity, significant interscale correlation was observed in the original five subscales and Positive Attitude. Each subscale including Positive Attitude was also significantly related to Depression and Anxiety of HADS. As a whole, the K-Mini-MAC was a reliable, valid and acceptable tool for Korean cancer patients. These findings can provide information about the cross-cultural validity of Mini-MAC scale's factor structure. Cultural differences were also discussed.

  15. A cost-effective fluorescence mini-microscope for biomedical applications.

    Science.gov (United States)

    Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali

    2015-01-01

    We have designed and fabricated a miniature microscope from off-the-shelf components and a webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters, such as cell/tissue viability (e.g. live/dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60×, achieves a resolution as high as microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including, but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread application in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required.

  16. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  17. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  18. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    Science.gov (United States)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  19. MINI-THESAURUS, Energy Data Base Subject Thesaurus Generator

    International Nuclear Information System (INIS)

    Paulk, J.W.

    2003-01-01

    1 - Description of program or function: MINI-THESAURUS allows the user to subset into highly-specialized 'mini-thesauri' the Energy Data Base (EDB) Subject Thesaurus, which contains the standard vocabulary of indexing terms (descriptors) developed and structured by the Office of Scientific and Technical Information (OSTI) for the building and maintenance of the U.S. Department of Energy (DOE) energy information databases. This structured vocabulary reflects the scope of DOE's research, development, and technological programs and encompasses terminology derived not only from the basic sciences but also from the areas of energy, conservation, safety, environmental impact, and regulation. Entire word blocks may be copied from the primary Subject Thesaurus, from another mini-thesaurus, or both, and subsequently modified through the addition of new terms, the deletion of existing terms, and changes to the internal relationships among the word blocks within the mini-thesaurus to create a new, special-purpose thesaurus. MINI-THESAURUS also provides the ability to copy the entire Subject Thesaurus and to treat the copy as a mini-thesaurus, thus allowing one to examine the effects of major changes to the thesaurus structure without having to modify the primary, on-line Thesaurus. The copy operation also optimizes the Subject Thesaurus structure. An interactive user having update privileges for a specific mini-thesaurus and access to the TeX and PostScript proprietary software can produce the mini-thesaurus in printed publication format. Once the mini-thesaurus has been published, periodic supplements may be generated based on date of entry or change maintained by the Thesaurus software. 2 Restrictions on the complexity of the problem: The system enforces the OSTI rules for Thesaurus development

  20. Spurious RF signals emitted by mini-UAVs

    Science.gov (United States)

    Schleijpen, Ric (H. M. A.); Voogt, Vincent; Zwamborn, Peter; van den Oever, Jaap

    2016-10-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to the sensor community. The detection, classification and identification chain can take advantage of different sensor technologies. Apart from the signatures used by radar and electro-optical sensor systems, the UAV also emits RF signals. These RF signatures can be split in intentional signals for communication with the operator and un-intentional RF signals emitted by the UAV. These unintentional or spurious RF emissions are very weak but could be used to discriminate potential UAV detections from false alarms. The goal of this research was to assess the potential of exploiting spurious emissions in the classification and identification chain of mini-UAVs. It was already known that spurious signals are very weak, but the focus was on the question whether the emission pattern could be correlated to the behaviour of the UAV. In this paper experimental examples of spurious RF emission for different types of mini-UAVs and their correlation with the electronic circuits in the UAVs will be shown

  1. Mini-Sniffer III on Lakebed

    Science.gov (United States)

    1976-01-01

    The third remotely-piloted Mini-Sniffer research vehicle rests on the lakebed adjacent to the Dryden Flight Research Center, Edwards, California. This view shows the wing shape, hydrazine engine, and the tail booms. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  2. Feasibility of mini-tablets as a flexible drug delivery tool.

    Science.gov (United States)

    Mitra, Biplob; Chang, Jessica; Wu, Sy-Juen; Wolfe, Chad N; Ternik, Robert L; Gunter, Thomas Z; Victor, Michael C

    2017-06-15

    Mini-tablets have potential applications as a flexible drug delivery tool in addition to their generally perceived use as multi-particulates. That is, mini-tablets could provide flexibility in dose finding studies and/or allow for combination therapies in the clinic. Moreover, mini-tablets with well controlled quality attributes could be a prudent choice for administering solid dosage forms as a single unit or composite of multiple mini-tablets in patient populations with swallowing difficulties (e.g., pediatric and geriatric populations). This work demonstrated drug substance particle size and concentration ranges that achieve acceptable mini-tablet quality attributes for use as a single or composite dosage unit. Immediate release and orally disintegrating mini-tablet formulations with 30μm to 350μm (particle size d 90 ) acetaminophen and Compap™ L (90% acetaminophen) at concentrations equivalent to 6.7% and 26.7% acetaminophen were evaluated. Mini-tablets achieved acceptable weight variability, tensile strength, friability, and disintegration time at a reasonable solid fraction for each formulation. The content uniformity was acceptable for mini-tablets of 6.7% formulations with ≤170μm drug substance, mini-tablets of all 26.7% formulations, and composite dosage units containing five or more mini-tablets of any formulation. Results supported the manufacturing feasibility of quality mini-tablets, and their applicability as a flexible drug delivery tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Mini-marathon groups: psychological "first aid" following disasters.

    Science.gov (United States)

    Terr, L C

    1992-01-01

    Large group counseling sessions for soldiers following battle have been commonly used since World War II. The author conceptualizes and demonstrates how these mini-marathon sessions can be adapted to support all ages and types of civilians involved in disasters. Mini-marathons take about 3 hours and are divided into three sections: story sharing, symptom sharing, and suggestions for self-help, including sharing tales of heroism and survival. After an initial mini-marathon session, a second session may be held emphasizing creativity. The author also describes how mini-marathons can be adapted for therapists who will lead their own sessions.

  4. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  5. Heat transfer and pressure drop characteristics of mini-fin structures

    International Nuclear Information System (INIS)

    Jiang Peixue; Xu Ruina

    2007-01-01

    Forced convection heat transfer of air and water in bronze and pure copper mini-fin structures and mini-channel structures was investigated experimentally. The mini-fin dimensions were 0.7 mm x 0.2 mm and 0.8 mm x 0.4 mm. The tests included both staggered diamond-shaped and in-line square mini-fin arrangements. The tests investigated the effects of structures, mini-fin dimensions and arrangement, test section materials, and fluid properties on the convection heat transfer and heat transfer enhancement. For the tested conditions, the convection heat transfer coefficient was increased 9-21 fold for water and 12-38 fold for air in the mini-fin structures compared with an empty plate channel. The friction factor and flow resistance in the mini-channel structures and the in-line square mini-fin arrangement were much less than in the staggered diamond-shaped mini-fin arrangement. For the small channel width, W c = 0.2 mm, the convection heat transfer with the in-line square array structure was more intense than with the staggered diamond-shaped structure, the mini-channel structure or the porous media. For the larger channel width, W c = 0.4 mm, the convection heat transfer in the staggered diamond-shaped array structure was more intense than in the others systems while the in-line square structure had the best overall thermal-hydraulic performance

  6. Development of mini-LIA and primary experiments

    International Nuclear Information System (INIS)

    Cheng Cheng; Liao Shuqing; Zheng Shuxin; Lin Yuzheng; Tang Chuanxiang; Jing Xiaobing; Mu Fan; Pan Haifeng; Zhang Kaizhi; Shi Jinshui; Deng Jianjun

    2009-01-01

    Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

  7. Mini lathe machine converted to CNC

    Directory of Open Access Journals (Sweden)

    Alexandru Morar

    2012-06-01

    Full Text Available This paper presents the adaptation of a mechanical mini-lathing machine to a computerized numerical control (CNC lathing machine. This machine is composed of a ASIST mini-lathe and a two-degrees-of-freedom XZ stage designed specifically for this application. The whole system is controlled from a PC using adequate CNC control software.

  8. Detection of dementia in primary care: comparison of the original and a modified Mini-Cog Assessment with the Mini-Mental State Examination.

    Science.gov (United States)

    Kamenski, Gustav; Dorner, Thomas; Lawrence, Kitty; Psota, Georg; Rieder, Anita; Schwarz, Franz; Sepandj, Asita; Spiegel, Wolfgang; Strotzka, Stefan

    2009-12-01

    Background Dementia is considered widely under-detected in primary care, and general practitioners (GPs) frequently ask for easy to use tools to assist in its early detection.Aim To determine the degree of correlation between the Mini-Cog Assessment (Mini-Cog) as performed by GPs and the Mini-Mental State Examination (MMSE).Design of study This was a prospective study (2005, 2006) comparing two cognitive screening instruments.Setting Ten general practices in Austria, with patients with a hitherto undiagnosed suspicion of dementia seen consecutively.Method Sensitivity, specificity and positive and negative predictive values (PPVs and NPVs) of the Mini-Cog (applying both a colour-coded and the original rating method) were assessed for degree of correlation with the MMSE. In phase one GPs examined patients suspected of having dementia using the Mini-Cog; in phase two a neurologist retested them applying the MMSE, a clock-drawing test (CDT) and a routine clinical examination. A questionnaire on the practicability of the Mini-Cog was answered by GPs.Results Of the 107 patients who participated 86 completed the whole study protocol. The Mini-Cog, as performed by the ten GPs, displayed a sensitivity of 0.85 (95% CI: 0.71, 0.98), a specificity of 0.58 (95% CI: 0.46, 0.71), a PPV of 0.47 (95% CI: 0.33, 0.61) and an NPV of 0.90 (95% CI: 0.80, 0.99) as against the MMSE carried out by neurologists. The GPs judged the Mini-Cog useful and time saving.Conclusion The Mini-Cog has a high sensitivity and acceptable specificity in the general practice setting and has proved to be a practicable tool for the diagnosis of dementia in primary care.

  9. Prospects for Antineutrino Running at MiniBooNE

    OpenAIRE

    Wascko, M. O.

    2006-01-01

    MiniBooNE began running in antineutrino mode on 19 January, 2006. We describe the sensitivity of MiniBooNE to LSND-like nuebar oscillations and outline a program of antineutrino cross-section measurements necessary for the next generation of neutrino oscillation experiments. We describe three independent methods of constraining wrong-sign (neutrino) backgrounds in an antineutrino beam, and their application to the MiniBooNE antineutrino analyses.

  10. Use of mini dental implants in ectodermal dysplasia children: follow-up of three cases.

    Science.gov (United States)

    Sfeir, E; Nassif, N; Moukarzel, C

    2014-07-01

    Ectodermal dysplasia is a hereditary genodermatosis characterised by a congenital defect of ectodermal structures, causing tooth malformations and anomalies. Implantology has become accepted in these subjects. However cases are often complicated by a reduction in the size of the alveolar process, making the insertion of conventional implants difficult without bone grafting. The reduced diameter of mini-implants and their ease of insertion provide an interesting solution in supporting removable or fixed prosthesis. The purpose of this paper is to report the follow-up of three cases of children (11-12 year- old) with ectodermal dysplasia in which mini-implants were used to support the prostheses. In the first case, two mini-implants were inserted into the anterior part of the mandible for stabilising a removable denture (2 years follow-up). In the other two cases, mini- implants were inserted in the maxilla and mandible to replace missing front teeth with fixed prostheses. Patients were called for follow- up every 6 months: in the sencod case follow-up lasted 4 years in the mandible and 2 years in the maxilla; in the third case, 2 years in the maxilla and 1 year in the mandible. The use of mini-implants in children with ectodermal dysplasia can enhance aesthetics, and functional and psychosocial development.

  11. A mini-UAV VTOL Platform for Surveying Applications

    Directory of Open Access Journals (Sweden)

    Kuldeep Rawat

    2014-05-01

    Full Text Available In this paper we discuss implementation of a mini-Unmanned Aerial Vehicle (UAV vertical take-off and landing (VTOL platform for surveying activities related to highway construction. Recent advances in sensor and communication technologies have allowed scaling sizes of unmanned aerial platforms, and explore them for tasks that are economical and safe over populated or inhabited areas. In highway construction the capability of mini-UAVs to survey in hostile and/or hardly accessible areas can greatly reduce human risks. The project focused on developing a cost effective, remotely controlled, fuel powered mini-UAV VTOL (helicopter platform with certain payload capacity and configuration and demonstrated its use in surveying and monitoring activities required for highway planning and construction. With an on-board flight recorder global positioning system (GPS device, memory storage card, telemetry, inertial navigation sensors, and a video camera the mini-UAV can record flying coordinates and relay live video images to a remote ground receiver and surveyor. After all necessary integration and flight tests were done the mini-UAV helicopter was tested to operate and relay video from the areas where construction was underway. The mini-UAV can provide a platform for a range of sensors and instruments that directly support the operational requirements of transportation sector.

  12. Designing a mini subcritical nuclear reactor; Diseno de un mini reactor nuclear subcritico

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M., E-mail: rafelaescobedo@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Jardin Juarez 147, Col. Centro, 98000 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of {sup 239}PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of {sup 239}PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k{sub e}-f{sub f}, the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k{sub eff}, the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons {sup 239}PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k{sub eff} was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k{sub eff} of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five

  13. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  14. Mini International Neuropsychiatric Interview (MINI: validação de entrevista breve para diagnóstico de transtornos mentais

    Directory of Open Access Journals (Sweden)

    Amorim Patrícia

    2000-01-01

    Full Text Available Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos, compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas. A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudos de validação do instrumento, realizados na Europa e nos EUA. Métodos: Os estudos 1 (França e 2 (EUA testaram a confiabilidade -entre avaliadores e teste-reteste -da versão DSM-III-R do MINI (n=84, sendo 42 pacientes psiquiátricos de cada centro e sua validade com relação ao CIDI (n=346, sendo 296 pacientes psiquiátricos e 50 controles e ao SCID-P (n=370, sendo 308 pacientes psiquiátricos e 62 controles, respectivamente. O estudo 3 testou a validade de diagnósticos gerados por clínicos gerais usando o MINI (DSM-IV com relação aos diagnósticos clínicos habituais de psiquiatras, em 409 pacientes de centros de atenção primária de quatro países (França, Espanha, Itália e Reino Unido. O estudo 4 testou a confiabilidade entre avaliadores (n=20 pacientes psiquiátricos e a validade dos módulos Transtornos Psicóticos, Depressão e Mania do MINI Plus - DSM IV (n=104 pacientes psiquiátricos com relação a dois critérios de referência: diagnósticos do CIDI e diagnósticos clínicos de psiquiatras. Análises quantitativas (índices de concordância e de validade e qualitativas (razões de discordância foram realizadas. Resultados: Os índices de confiabilidade do MINI (estudos 1 e 2 e do MINI Plus (estudo 4 foram globalmente satisfatórios. Comparados a vários critérios de referência (CIDI, SCID-P, opinião de peritos, em diferentes contextos (unidades psiquiátricas e centros de atenção primária, o MINI e o MINI

  15. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  16. The Mini-Cog, Clock Drawing Test, and the Mini-Mental State Examination in a German memory clinic: specificity of separation dementia from depression.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2013-01-01

    The aim of this study was to assess the specificities of the Mini-Cog, the Clock Drawing Test (CDT), and the Mini-Mental State Examination (MMSE) against depression and healthy controls in a German Memory Clinic. Furthermore, we analyzed the specificities of all three screening instruments in dependence of actual depression severity. Data from 142 depressed elderly, 438 dementia patients, and 64 healthy controls were retrospectively analyzed. The CDT and an extraction of the three-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Depression severity was rated by either the Beck Depression Inventory (BDI) or the Geriatric Depression Scale (GDS) depending on the age of the patients. The Mini-Cog achieved a specificity of 79.6% against depressed elderly and 100.0% against healthy subjects (p Mini-Cog and the CDT, but also showed the lowest sensitivity for the detection of dementia. Surprisingly, the depression severity had no effect on the specificity of the Mini-Cog and the CDT, only the MMSE was susceptible for the depression severity. Although the MMSE showed higher specificities, the weighting between the sensitivities and specificities in all tests prove again the Mini-Cog as a short, valid, and sensitive screening tool.

  17. Validation and cultural adaptation of the Arabic versions of the Mini-Mental Status Examination - 2 and Mini-Cog test.

    Science.gov (United States)

    Albanna, Mohammad; Yehya, Arij; Khairi, Abdalla; Dafeeah, Elnour; Elhadi, Abdelsalam; Rezgui, Lamia; Al Kahlout, Shahada; Yousif, Adil; Uthman, Basim; Al-Amin, Hassen

    2017-01-01

    The elderly population is increasing around the world, and the prevalence of dementia increases with age. Hence, it is expected that the number of people with dementia will increase significantly in the coming years. The Mini-Mental Status Examination - 2 (MMSE-2) and Mini-Cog are widely used tests to screen for dementia. These scales have good reliability and validity and are easy to administer in clinical and research settings. The purpose of this study was to validate the Arabic versions of MMSE-2 and Mini-Cog. These scales were assessed against the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision ( DSM-IV-TR ) criteria for dementia, as the gold standard. The standard versions of the MMSE-2 and Mini-Cog were translated to Arabic following the back-translation method. Then, a trained rater administered these tests to 134 Arab elderly aged >60 years. A physician, blind to the results of these two tests, assessed the participants for vascular dementia or probable Alzheimer's disease, based on the DSM-IV-TR criteria. The sample included 67.2% Qataris. The mean age was 74.86 years (standard deviation =7.71), and 61.9% did not attend school. The mean of the adjusted scores of MMSE-2 based on age and education level was 19.60 (standard deviation =6.58). According to DSM-IV-TR , 17.2% of the participants had dementia. Sensitivity and specificity of the MMSE-2 and the Mini-Cog together were 71.4% and 61.6%, respectively, which were better than those of each test alone. Together, the Arabic versions of MMSE-2 and Mini-Cog are good screening tools for cognitive impairment in Arabs.

  18. Reasons for mini-implants failure: choosing installation site should be valued!

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-04-01

    Full Text Available Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1 Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2 Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3 Low bone density, low thickness and low alveolar bone volume; 4 Low alveolar cortical bone thickness; 5 Excessive pressure inducing trabecular bone microfracture; 6 Sites of higher anatomical weakness in the mandible and the maxilla; 7 Thicker gingival tissue not considered when choosing the mini-implant.

  19. Congenital hypogonadotropic hypogonadism: implications of absent mini-puberty.

    Science.gov (United States)

    Dwyer, Andrew A; Jayasena, Channa N; Quinton, Richard

    2016-06-01

    The phenomenon known as "mini-puberty" refers to activation of the neonatal hypothalamo-pituitary axis causing serum concentrations of gonadotrophins and testosterone (T) to approach adult male levels. This early neonatal period is a key proliferative window for testicular germ cells and immature Sertoli cells. Although failure to spontaneously initiate (adolescent) puberty is the most evident consequence of a defective gonadotropin-releasing hormone (GnRH) neurosecretory network, absent mini-puberty is also likely to have a major impact on the reproductive phenotype of men with congenital hypogonadotrophic hypogonadism (CHH). Furthermore, the phase of male mini-puberty represents a key window-of-opportunity to identify congenital GnRH deficiency (either isolated CHH, or as part of combined pituitary hormone deficiency) in childhood. Among male neonates exhibiting "red flag" indicators for CHH (i.e. maldescended testes with or without cryptorchidism) a single serum sample (between 4-8 weeks of life) can pinpoint congenital GnRH deficiency far more rapidly and with much greater accuracy than dynamic tests performed in later childhood or adolescence. Potential consequences for missing absent mini-puberty in a male neonate include the lack of monitoring of pubertal progression/lack of progression, and the missed opportunity for early therapeutic intervention. This article will review our current understanding of the mechanisms and clinical consequences of mini-puberty. Furthermore, evidence for the optimal clinical management of patients with absent mini-puberty will be discussed.

  20. Virtual laboratory of electrical mini-grids with distributed generation

    International Nuclear Information System (INIS)

    Menezes Ramos, Vanessa; Barros Galhardo, Marcos André; Oliveira Barbosa, Claudomiro Fábio de; Tavares Pinho, João

    2015-01-01

    This paper presents a computing tool called Virtual Laboratory de Minirredes (Virtual Laboratory of Mini-grids). Using the virtual environment of the developed tool, it is possible to make remote connection/disconnection of switches and loads (resistive, inductive, capacitive and non-linear) at strategic points of the electric mini-grid with hybrid distributed generation systems (solar photovoltaic-diesel). The mini-grid has a length of about 1 km and is installed in the test area of the Grupo de Estudios e Desenvolvimento de Alternativas Exergética (GEDAE) of the Universidade Federal do Pará, located in the city of Belém, Pará, Brazil. The developed tool has communication functions with electric parameters transducers and programmable logic controllers (PLCs). This communication enables the opening and closing of contactors, resulting in different settings for the mini-grid. In addition to that, based on the proposed configuration by the user, the real-time operation status of mini-grid is presented in a graphic interface (for example, monitored electric parameters, distributed generators connected, status of disconnected switches, etc.) and the acquired data is stored. The use of the computing tool also focuses on the construction of a database, in order to obtain knowledge about the mini-grid performance under various conditions that can be set, depending on the operational strategy adopted, based on the choice of the layout, loads and power sources used in the mini-grid. (full text)

  1. Mini AERCam Inspection Robot for Human Space Missions

    Science.gov (United States)

    Fredrickson, Steven E.; Duran, Steve; Mitchell, Jennifer D.

    2004-01-01

    The Engineering Directorate of NASA Johnson Space Center has developed a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam free flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35 pound, 14 inch AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations including automatic stationkeeping and point-to-point maneuvering. Mini AERCam is designed to fulfill the unique requirements and constraints associated with using a free flyer to perform external inspections and remote viewing of human spacecraft operations. This paper describes the application of Mini AERCam for stand-alone spacecraft inspection, as well as for roles on teams of humans and robots conducting future space exploration missions.

  2. Mini-chamber, an advanced protection concept for NIF

    International Nuclear Information System (INIS)

    Peterson, P.F.; Scott, J.M.

    1996-01-01

    Inertial confinement fusion (ICF) target debris and ablated near-target materials pose the primary threat to the National Ignition Facility (NIF) final optics debris shields, as well as a major challenge in future inertial fusion energy (IFE) power plants. This work discusses a NIF 'mini-chamber,' designed to mitigate the debris threat. Although the NIF base-line design protects against debris using a frost-protected target positioner and refractory first-wall coatings, the mini-chamber provides important flexibility in three areas: debris-shield protection from beyond-design basis shots (i.e. heavy hohlraums, special diagnostics, shields); fielding of large experiments with significant surface ablation; and studying key ablation and gas-dynamics issues for liquid-wall IFE power plants. Key mini-chamber modeling results are presented, followed by discussion of equipment requirements for fielding a NIF mini-chamber. 7 refs., 3 figs

  3. Mini-Implants: New Possibilities in Interdisciplinary Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Biju Sebastian

    2014-01-01

    Full Text Available The introduction of mini-implants has broadened the range of tooth movements possible by fixed appliance therapy alone. The limits of fixed orthodontic treatment have become more a matter of facial appearance than anchorage. Many complex cases which would previously have required surgery or functional appliances can now be treated with fixed appliance therapy using mini-implants. A mutilated dentition case where mini-implants were used to provide anchorage for intrusion of molars and retraction of anterior teeth is reported here to illustrate this point.

  4. Energy efficient mini bars in hotel rooms; Energieffektive minibarer til hotelvaerelser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    The project 'Energy-efficient mini bars for hotel rooms' is carried out from February December 2005. The project is financed by Elfor's PSO funds and also by the participants in the project, HORESTA and Teknologisk Institut. Mini bars consume up to 10% of the total electricity costs of a hotel. Therefore, the energy consumption of mini bars has been brought into focus in this project. The existing mini bar market has been analysed and measurements have been carried out on the type of mini bars that are used most often. In that way, energy consumption, net volume, energy efficiency, energy labelling, noise level and cooling capacity have been determined. In the course of the project, mini bars from IndelB, Domestic and Vibocold have been tested. With regard to energy consumption, the test results showed large deviations from the consumption stated by the manufacturer. Only 1 of the 6 tested mini bars received an energy label B - the others were labelled with F or G. Therefore, there is a great potential for developing more energy efficient mini bars. A list covering the energy consumption, energy labelling, noise level etc. of the tested mini bars and a guide to new purchases can be found on HORESTA's homepage www.horesta.dk. (au)

  5. A Cost-Effective Fluorescence Mini-Microscope with Adjustable Magnifications for Biomedical Applications

    Science.gov (United States)

    Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali

    2015-01-01

    We have designed and fabricated a miniature microscope from off-the-shelf components and webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters such as cell/tissue viability (e.g. Live/Dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60X, achieves a resolution as high as microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread applications in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required. PMID:26282117

  6. Development on mini X-ray diode

    International Nuclear Information System (INIS)

    Jiang Shaoen; Sun Kexu; Peng Nengling; Huang Tianxuan; Cui Yanli; Yi Rongqing; Chen Jiusen

    2004-01-01

    The mini X-ray diode (M-XRD) was developed, and was used in mini soft X-ray spectrometer. Compared with traditional XRD, M-XRD's volume reduces to 1/30. M-XRD's property was experimentally examined on Shenguang II laser facility. The experimental results indicated that the temporal response and sensitivity of M-XRD are basically consistent with traditional XRD. The equivalent circuit of XRD was analyzed, and its response time and linear saturated current were calculated. (authors)

  7. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Science.gov (United States)

    Camacho, Macario; Zaghi, Soroush; Chang, Edward T.; Song, Sungjin A.; Szelestey, Blake; Certal, Victor

    2016-01-01

    Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes) in adult obstructive sleep apnea (OSA) patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review) for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm) or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed. PMID:26925105

  8. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Directory of Open Access Journals (Sweden)

    Macario Camacho

    2016-01-01

    Full Text Available Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes in adult obstructive sleep apnea (OSA patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed.

  9. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  10. Berkeley mini-collider

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1984-06-01

    The Berkeley Mini-Collider, a heavy-ion collider being planned to provide uranium-uranium collisions at T/sub cm/ less than or equal to 4 GeV/nucleon, is described. The central physics to be studied at these energies and our early ideas for a collider detector are presented

  11. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    The Law Protection Intellectual Property Right in Mini Market Retail Franchise in YogyakartaFranchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret.This research aims to ident...

  12. Orthodontic mechanics using mini-implant measured by FBG

    Science.gov (United States)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  13. Amelioration of Muscle and Nerve Pathology in LAMA2 Muscular Dystrophy by AAV9-Mini-Agrin

    Directory of Open Access Journals (Sweden)

    Chunping Qiao

    2018-06-01

    Full Text Available LAMA2-related muscular dystrophy (LAMA2 MD is the most common and fatal form of early-onset congenital muscular dystrophies. Due to the large size of the laminin α2 cDNA and heterotrimeric structure of the protein, it is challenging to develop a gene-replacement therapy. Our group has developed a novel adeno-associated viral (AAV vector carrying the mini-agrin, which is a non-homologous functional substitute for the mutated laminin α2. A significant therapeutic effect in skeletal muscle was observed in our previous study using AAV serotype 1 (AAV1. In this investigation, we examined AAV9 vector, which has more widespread transduction than AAV1, to determine if the therapeutic effects could be further improved. As expected, AAV9-mini-agrin treatment offered enhanced therapeutic effects over the previously used AAV1-mini-agrin in extending mouse lifespan and improvement of muscle pathology. Additionally, overexpression of mini-agrin in peripheral nerves of dyw/dyw mice partially amended nerve pathology as evidenced by improved motor function and sensorimotor processing, partial restoration of myelination, partial restoration of basement membrane via EM examination, as well as decreased regeneration of Schwann cells. In conclusion, our studies indicate that overexpression of mini-agrin into dyw/dyw mice offers profound therapeutic effects in both skeletal muscle and nervous system. Keywords: LAMA2, mini-agrin, muscular dystrophy, CMD, AAV, gene therapy

  14. Initial validation of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale: study of Portuguese end-of-life cancer patients.

    Science.gov (United States)

    Pereira, Filomena Moreira Pinto; Santos, Célia Samarina Vilaça de Brito

    2014-10-01

    The Mini-Mental Adjustment to Cancer Scale (Mini-MAC) is a 29-item instrument designed to evaluate the responses developed by cancer patients during their mental adjustment to diagnosis and treatment. This study aims to validate the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) translated and adapted to the Portuguese language and culture, in end-of-life cancer patients receiving palliative care. The instrument was administered to 346 Portuguese end-of-life cancer patients, receiving care through outpatient visits or admitted into palliative care units, without cognitive symptoms and with symptoms under control. A cross-sectional validation study using orthogonal rotation through the varimax method followed by convergent and discriminant validity. The analysis of the main components confirms the existence of five factors, demonstrating the validity of the construct, with good internal consistency in the subscales and Cronbach's alpha values between 0.78 and 0.93. Good test-retest reliability was also found, and r values for subscales ranged from 0.62 to 0.99. The instrument proved to be a reliable, valid and sensitive measure in the study of mental adjustment of Portuguese end-of-life patients with cancer receiving palliative care. Nurses can use the Mini-MAC Scale in research and clinical practice in order to evaluate the mental adjustment of Portuguese end-of-life cancer patients receiving palliative care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Maximum atmosphere at the Mini Atomiades

    CERN Multimedia

    Rachel Bray, Atomiades organizer team

    2016-01-01

    CERN Clubs Coordination Committee and CERN Staff Association host the ASCERI Mini Atomiades June 2016.   The CERN team won the tennis tournament for the Mini Atomiades 2016. (Photo: Erwin Van Hove) Over 180 participants from 10 different European Scientific Research Institutes came together on the first weekend of June in Divonne-les-Bains to take part in the ASCERI Sport & Science Mini Atomiades. Sports men and women from Belgium, Germany, France, Hungary, Russia and Switzerland battled it out in four different tournaments for medals, cups and, above all, lots of fun. The four disciplines included football, golf, tennis and a 10km race. CERN was victorious in tennis, golf and the men's and women's 10km, and despite the CERN football team putting up an excellent fight against some very strong teams they came almost last (we cannot win everything, can we?). But CERN were the clear winners for team spirit, community and camaraderie, as confirmed by all the comp...

  16. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  17. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  18. Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

    OpenAIRE

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 follo...

  19. Mini-mental Parkinson (MMP) as a dementia screening test: comparison with the Mini-Mental State Examination (MMSE).

    Science.gov (United States)

    Larner, Andrew J

    2012-07-01

    As populations age, screening instruments for cognitive impairment and dementia will become of increasing importance in clinical practice. Mini-Mental Parkinson (MMP), a derivative of the Mini-Mental State Examination (MMSE), was originally described as a cognitive screening instrument for use in Parkinson's disease. Its item content addresses some of the acknowledged shortcomings of the MMSE. Pragmatic use of MMP in general cognitive clinics has not previously been examined. To compare the performance of two scales, Mini-Mental Parkinson (MMP) and the Mini-Mental State Examination (MMSE), as cognitive screening instruments for dementia in a memory clinic population. MMP was administered prospectively to 201 consecutive new patient referrals independent of other tests used to establish dementia diagnosis according to standard diagnostic criteria (DSM-IV). Diagnostic utility of MMP for dementia was measured and compared with MMSE. MMP proved easy to use and acceptable to patients. Optimal test accuracy (0.86) was at MMP cutoff of ≤ 17/32, with sensitivity 0.51, specificity 0.97, positive predictive value 0.83, negative predictive value 0.87, and area under Receiver Operating Characteristic curve 0.89. Using a higher cutoff (≤ 29/32), MMP sensitivity was 1.00 with specificity 0.70. MMP scores correlated with MMSE (r = 0.93) and diagnostic agreement was high (κ = 0.85). MMP is a useful screening instrument in the memory clinic setting, with patients who fall below the designated cutoff requiring further investigation to ascertain a cause for their cognitive impairment.

  20. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...... of communicative and cooperative skills and 2) whether mini-CEX would provide reproducible data. MATERIAL AND METHODS: Twenty-one residents were evaluated by mini-CEX by trained observers. Seventeen residents had at least two observations within a short period of time and these data were used to estimate the mini...

  1. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    International Nuclear Information System (INIS)

    Hantao Ji

    2004-01-01

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers

  2. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Hantao Ji

    2004-02-27

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers.

  3. Screening for Dementia in Older Adults: Comparison of Mini-Mental State Examination, Mini-Cog, Clock Drawing Test and AD8.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin

    2016-01-01

    This study was conducted to estimate screening performance of dementia screening tools including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) for older adults. 2015 participants aged 65 years or more in eastern China were enrolled. 4 screening tests were administered and scored by specifically trained psychiatrists. We used data from two-by-two tables to calculate the sensitivity, specificity, and positive and negative predictive values (PPV/NPV). Our study showed that dementia was highly prevalent among elderly in Zhejiang province. The Mini-Cog, with excellent screening characteristics and spending less time, could be considered to be used as a screening tool among communities to help to diagnose dementia early.

  4. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  5. Measuring mental health in the clinical setting: what is important to service users? The Mini-Service user Recovery Evaluation scale (Mini-SeRvE).

    Science.gov (United States)

    Barber, Joanna M; Parsons, Helen; Wilson, Carol A; Cook, Christopher C H

    2017-12-01

    Since 2001, a policy of positive mental health recovery has been promoted in the UK, with service user involvement. This has not been easy to implement in the clinical setting. To develop and validate a brief self-report, service user-designed, outcome measure (Mini-SeRvE), for clinical use, including spiritual and religious issues. From the previously developed Service user Recovery Evaluation scale (SeRvE), 15 questions were selected for Mini-SeRvE which was self-completed by 207 people; 100 service users and, for comparison, 107 staff. Results were analysed using SPSS software (SPSS Inc., Chicago, IL). Mini-SeRvE is reliable, Cronbach's alpha 0.852. Correlation with another recovery scale, Mental Health Recovery Measure, was high, r = 0.819. Three reliable subscales emerged; existential well-being (EWB), mental ill-being (MIB) and religious well-being (RWB). Scores of the EWB and MIB subscales were higher for staff, consistent with higher mental well-being. Religious well-being scores were higher in service users, who also rated religion as more important to them. Mini-SeRvE is a valid measure of service user recovery. The importance of religion/spiritual belief for our users is highlighted, this being reflected in the subject matter of Mini-SeRvE. Mini-SeRvE assessments could show individual priorities, evaluate therapy and aid clinical decision-making.

  6. Taman Mini Indonesia Indah sebagai Bagian dari Fenomena Taman Budaya Dunia

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Wulandari

    2012-10-01

    Full Text Available Cultural display in an open space or known as cultural parks appears rapidly as a worldwide phenomenon. From the European model which has a strong educational value, to the Asian parks which not only has educational function, but also has recreational purposes. So many types and characteristics of these parks, researches give them different names, thodse are Open-air museums, Ethnographic Theme Parks or even Theme Parks. Taman Mini Indonesia Indah as a part of this phenomenon was built first and foremost for educational purposes, therefore Taman Mini can be considered as an open-air museum. However, since Taman Mini also has recreational purposes, others can argue that Taman Mini is a theme park. Qualitative method will be used for this research, through observation to Taman Mini Indonesia Indah, followed by extensive literature review. With these data along with a table which points out the distinction between museum and theme parks. It can  be concluded that Taman Mini is a Theme Park.   

  7. Refining MARGINS Mini-Lessons Using Classroom Observations

    Science.gov (United States)

    Iverson, E. A.; Manduca, C. A.; McDaris, J. R.; Lee, S.

    2009-12-01

    One of the challenges that we face in developing teaching materials or activities from research findings is testing the materials to determine that they work as intended. Traditionally faculty develop material for their own class, notice what worked and didn’t, and improve them the next year. However, as we move to a community process of creating and sharing teaching materials, a community-based process for testing materials is appropriate. The MARGINS project has piloted such a process for testing teaching materials and activities developed as part of its mini-lesson project (http://serc.carleton.edu/margins/index.html). Building on prior work developing mechanisms for community review of teaching resources (e.g. Kastens, 2002; Hancock and Manduca, 2005; Mayhew and Hall, 2007), the MARGINS evaluation team developed a structured classroom observation protocol. The goals of field testing are to a) gather structured, consistent feedback for the lesson authors based on classroom use; b) guide reviewers of these lessons to reflect on research-based educational practice as a framework for their comments; c) collect information on the data and observations that the reviewer used to underpin their review; d) determine which mini-lessons are ready to be made widely available on the website. The protocol guides faculty observations on why they used the activity, the effectiveness of the activity in their classroom, the success of the activity in leading to the desired learning, and what other faculty need to successfully use the activity. Available online (http://serc.carleton.edu/margins/protocol.html), the protocol can be downloaded and completed during instruction with the activity. In order to encourage review of mini-lessons using the protocol, a workshop focused on review and revision of activities was held in May 2009. In preparation for the workshop, 13 of the 28 participants chose to field test a mini-lesson prior to the workshop and reported that they found this

  8. A mini-microscope for in situ monitoring of cells.

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  9. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  10. Mini-implantes ortodônticos como auxiliares da fase de retração anterior Orthodontic mini-implants assisting the anterior retraction phase

    Directory of Open Access Journals (Sweden)

    Carlo Marassi

    2008-10-01

    Full Text Available INTRODUÇÃO: os mini-implantes ortodônticos se estabeleceram como um importante método de ancoragem e vêm auxiliando os ortodontistas nas várias etapas do tratamento ortodôntico, eliminando, em grande parte, a necessidade de colaboração dos pacientes e tornando os resultados mais previsíveis. OBJETIVO: este artigo descreve os principais aspectos do uso dos mini-implantes como auxiliares da fase de retração anterior, trazendo considerações sobre suas indicações, quantidade de movimentação dos dentes anteriores, os vetores de força de retração, o controle vertical, o posicionamento dos mini-implantes, os tipos de apoio na região anterior e a força a ser utilizada. São citados os sítios de instalação mais usados para a retração anterior e abordados fatores que deverão ser controlados durante o fechamento de espaço. Por fim, são citadas algumas considerações clínicas sobre o uso dos mini-implantes nessa importante fase do tratamento ortodôntico.INTRODUCTION: The use of orthodontic mini-implants has settled as an important anchorage method and is aiding the orthodontists in the several stages of the treatment, largely eliminating the need of patients' compliance, and turning the results more predictable. AIM: This article describes the main aspects of the use of mini-implants as auxiliaries on the retraction phase of the anterior teeth, bringing considerations about their indications, amount of movement of the anterior teeth, the vectors of retraction force, the vertical control and evaluation of the incisors vestibulolingual tipping, the positioning of the mini-implants, the support types in the anterior area and the force to be applied. The placement sites best used for the anterior retraction are mentioned, and the factors that should be controlled during the space closure are approached. Lastly, some clinical considerations on the use of mini-implants in such important phase of the orthodontic treatment are

  11. The Mini-Cog versus the Mini-Mental State Examination and the Clock Drawing Test in daily clinical practice: screening value in a German Memory Clinic.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2012-05-01

    The aim of this study was to compare the screening value of the Mini-Cog, Clock Drawing Test (CDT), Mini-Mental State Examination (MMSE) and the algorithm MMSE and/or CDT to separate elderly people with dementia from healthy depending on test time, type and severity of dementia, and demographic variables in a German Memory Clinic. Data from a heterogeneous patient sample and healthy participants (n = 502) were retrospectively analyzed. Of the 438 patients with dementia, 49.1% of the dementia diagnoses were Alzheimer's dementia and 50.9% were non-Alzheimer's dementia. Sixty-four participants were classified as cognitively unimpaired. The CDT and an extraction of the 3-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Overall, the Mini-Cog showed significantly higher discriminatory power (86.8%) than the MMSE (72.6% at a cut-off ≤ 24 and 79.2% at ≤ 25, respectively) and CDT (78.1%) (each p 0.05). The specificity of the Mini-Cog (100.0%) was similar to that of the MMSE (100.0% for both cut-offs) and CDT (96.9%) (p = 0.154). For all age and educational groups the Mini-Cog outmatched the CDT and MMSE, and was less affected by education than MMSE and less susceptible for the dementia stage than the CDT. The Mini-Cog proved to have superior discriminatory power than either CDT or MMSE and is demonstrated to be a valid "short" screening instrument taking 3 to 4 minutes to administer in the geriatric setting.

  12. Characterization of surface topography and chemical composition of mini-implants

    OpenAIRE

    Knop, Luegya Amorim Henriques; Soares, Ana Prates; Shintcovsk, Ricardo Lima; Martins, Lidia Parsekian; Gandini Jr., Luiz Gonzaga

    2015-01-01

    Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis ...

  13. Late time CMB anisotropies constrain mini-charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Burrage, C.; Redondo, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Jaeckel, J. [Univ. of Durham, Inst. for Particle Physics Phenomenology (United Kingdom)

    2009-09-15

    Observations of the temperature anisotropies induced as light from the CMB passes through large scale structures in the late universe are a sensitive probe of the interactions of photons in such environments. In extensions of the Standard Model which give rise to mini-charged particles, photons propagating through transverse magnetic fields can be lost to pair production of such particles. Such a decrement in the photon flux would occur as photons from the CMB traverse the magnetic fields of galaxy clusters. Therefore late time CMB anisotropies can be used to constrain the properties of mini- charged particles. We outline how this test is constructed, and present new constraints on mini-charged particles from observations of the Sunyaev-Zel'dovich effect in the Coma cluster. (orig.)

  14. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  15. Mini-Grids for the Base of the Pyramid Market: A Critical Review

    Directory of Open Access Journals (Sweden)

    Subhes C. Bhattacharyya

    2018-04-01

    Full Text Available The lack of access to electricity of more than 1.1 billion people around the world remains a major developmental challenge and Goal 7 of the Sustainable Development Goals (SDG as well as Sustainable Energy for All (SE4ALL have set a target of universal electrification by 2030. Various studies have identified mini-grid-based electrification as a possible solution. There is a growing body of literature available now that has explored the feasibility, practical application and policy interventions required to support mini-grids. Through a review of available literature, this paper explores whether mini-grids can be a solution for the base of the pyramid (BoP market and the challenges faced in deploying mini-grids in such markets. Interventions to support the mini-grid deployment are also discussed. The paper finds that the mini-grids are targeting the BoP market but the business is not attractive in profitability terms and requires financial support. Lack of regulatory clarity and non-coordinated policies affect the financial viability of projects, which requires careful support. Mini-grid electrification has hardly been embedded in rural development agenda and hence they have not contributed significantly to livelihood generation. Careful realignment of policies, regulatory frameworks and support systems can better support mini-grid deployment in developing countries.

  16. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics.

    Science.gov (United States)

    El-Say, Khalid M; Ahmed, Tarek A; Abdelbary, Maged F; Ali, Bahaa E; Aljaeid, Bader M; Zidan, Ahmed S

    2015-12-01

    This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets) as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1), swelling pressure of the superdisintegrant (X2), and the surface area of Aerosil as a glidant (X3). Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for pre- and post-compression characteristics. The prepared OD-mini-tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2) and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  17. Accelerated Tooth Movement with Orthodontic Mini-Screws

    Directory of Open Access Journals (Sweden)

    S. Aksakalli

    2017-01-01

    Full Text Available This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-year-old male patient presented Class II malocclusion with maxillary incisor protrusion. Upper first premolars were extracted, and after leveling, accelerated canine distalization started. For pre- and postdistalization times, amount of distalization, periodontal health, and root resorption were assessed. Within the limitations of this case report, micro-osteoperforations with mini-screw have a potential for shortening the treatment time.

  18. Predicting everyday functional abilities of dementia patients with the Mini-Mental State Examination.

    Science.gov (United States)

    Razani, Jill; Wong, Jennifer T; Dafaeeboini, Natalia; Edwards-Lee, Terri; Lu, Po; Alessi, Cathy; Josephson, Karen

    2009-03-01

    The Mini-Mental State Examination is a widely used cognitive screening measure. The purpose of the present study was to assess how 5 specific clusters of Mini-Mental State Examination items (ie, subscores) correlate with and predict specific areas of daily functioning in dementia patients, 61 patients with varied forms of dementia were administered the Mini-Mental State Examination and an observation-based daily functional test (the Direct Assessment of Functional Status). The results revealed that the orientation and attention subscores of the Mini-Mental State Examination correlated most significantly with most functional domains. The Mini-Mental State Examination language items correlated with all but the shopping and time orientation tasks, while the Mini-Mental State Examination recall items correlated with the Direct Assessment of Functional Status time orientation and shopping tasks. Stepwise regression analyses found that among the Mini-Mental State Examination subscores, orientation was the single, best independent predictor of daily functioning.

  19. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    Science.gov (United States)

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    -4.0 and -4.9, respectively. The primary and secondary stability values for the mini-dental implants were -0.3 and -1.4, respectively. The Periotest values of the primary (measured immediately after implant insertion) and secondary implant stabilities (measured 6 months after implant insertion) were significantly higher for the conventional dental implants than for the mini-dental implants (Pdental implants had clinical outcomes similar to those of patients receiving conventional dental implants to support overdenture prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Validity of a short clinical interview for psychiatric diagnosis: the mini-SCAN.

    Science.gov (United States)

    Nienhuis, F J; van de Willige, G; Rijnders, C A Th; de Jonge, P; Wiersma, D

    2010-01-01

    To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. To establish the validity and practical properties of the mini-SCAN. One hundred and six participants were interviewed twice, once with the SCAN and once with the mini-SCAN. The level of agreement was established for the categories: no disorder, affective disorders, anxiety disorders, non-affective psychotic disorders, affective psychotic disorders. The mini-SCAN is a valid instrument. Most kappa values were around 0.90. Only for the class of affective psychotic disorders was the agreement moderate. Mean duration of the mini-SCAN interviews was 25 min shorter than the SCAN interviews. Participants and interviewers were generally satisfied with the interview format and questions. The mini-SCAN can be used as a diagnostic instrument for clinical purposes and for clinical studies when the present episode is the focus of attention.

  1. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  2. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  3. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  4. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  5. Delphi report 1995 on developments in science and technology. Mini Delphi; Delphi-Bericht 1995 zur Entwicklung von Wissenschaft und Technik. Mini-Delphi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    In August 1993 the first German `Delphi Report on Developments in Science and Technology` was published. It was elaborated by the Fraunhofer Institute for System Engineering and Innovation Research (FhG-ISI) in cooperation with the Japanese National Institute of Science and Technology Policy (NISTEP). The `MINI-DELPHI` now completed by FhG-ISI, again in cooperation with NISTEP, is a further development of the Delphi approach in that it is more differentiated in its questions and assessment criteria than its predecessors. `MINI-DELPHI` is not intended as a comprehensive forecast on technology in general but rather focusses on key topics. Its emphasis is on technology demand and the relevance of technologies to social issues. Although the Mini-Delphi study was primarily aimed at further refining the methodology employed, it nevertheless contains a wealth of information and details on circumscript questions. The requisite database is provided by tables on the results of two inquiry rounds among Japanese and German experts. (orig./RHM) [Deutsch] Im August 1993 wurde der erste deutsche `Delphi-Bericht zur Entwicklung von Wissenschaft und Technik` veroeffentlicht. Er war vom Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung (FhG-ISI) in Zusammenarbeit mit dem japanischen National Institute of Science and Technology Policy (NISTEP) erarbeitet worden. Mit dem jetzt vorliegenden `MINI-DELPHI` hat das FhG-ISI - wieder in Zusammenarbeit mit dem NISTEP - den Delphi-Ansatz fortentwickelt und sowohl hinsichtlich der Fragen als auch der Beurteilungskriterien weiter ausdifferenziert. `MINI-DELPHI` bezweckt keine umfassende Technologievorausschau, sondern konzentriert sich auf Schluesselthemen. Im Vordergrund steht der Gedanke des Technikbedarfs und die Relevanz fuer gesellschaftliche Fragestellungen. Obwohl die Mini-Delphi-Studie vorrangig der Weiterentwicklung der Methodik dient, enthaelt sich eine Fuelle von Informationen und Details zu Einzelfragen. Die im Bericht

  6. Designing a mini subcritical nuclear reactor

    International Nuclear Information System (INIS)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M.

    2015-10-01

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of 239 PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of 239 PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k e -f f , the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k eff , the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons 239 PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k eff was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k eff of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five cylinders not met. (Author)

  7. Pedicled Descending Branch Latissimus Dorsi Mini-flap for Repairing Partial Mastectomy Defect: A New Technique

    Directory of Open Access Journals (Sweden)

    Ruizhao Cai, M.D.

    2018-03-01

    Full Text Available Summary:. Volume loss is 1 of the major factors influencing cosmetic outcomes of breast after partial mastectomy (PM, especially for smaller breasts, and therefore, volume replacement is critical for optimizing the final aesthetic outcome. We present a novel technique of raising a pedicled descending branch latissimus dorsi (LD mini-flap for reconstruction of PM defects via an axillary incision. After PM, the LD mini-flap is harvested through the existing axillary incision of the axillary dissection or the sentinel lymph node biopsy. The descending branches of thoracodorsal vessels and nerve are carefully identified and isolated. The transverse branches are protected to maintain muscle innervation and function. The LD muscle is then undermined posteriorly and inferiorly to create a submuscular pocket and a subcutaneous pocket between LD muscle and superficial fascia. Once the submuscular plane is created, the muscle is divided along the muscle fibers from the deep surface including a layer of fat above the muscle. Finally, the LD mini-flap is transferred to the breast defect. Given the limited length and mobility of the LD mini-flap, this approach is best utilized for lateral breast defects. However, for medial defects, the lateral breast tissue is rearranged to reconstruct the medial breast defect, and an LD mini-flap is then used to reconstruct the lateral breast donor site. This technique can therefore be employed to reconstruct all quadrants of the breast and can provide aesthetic outcomes without scars on the back, with minimal dysfunction of LD muscle.

  8. Internal Structure of Mini-CEX Scores for Internal Medicine Residents: Factor Analysis and Generalizability

    Science.gov (United States)

    Cook, David A.; Beckman, Thomas J.; Mandrekar, Jayawant N.; Pankratz, V. Shane

    2010-01-01

    The mini-CEX is widely used to rate directly observed resident-patient encounters. Although several studies have explored the reliability of mini-CEX scores, the dimensionality of mini-CEX scores is incompletely understood. Objective: Explore the dimensionality of mini-CEX scores through factor analysis and generalizability analysis. Design:…

  9. Mini-Digest of Education Statistics, 2008. NCES 2009-021

    Science.gov (United States)

    Snyder, Thomas D.

    2009-01-01

    This publication is the 14th edition of the "Mini-Digest of Education Statistics," a pocket-sized compilation of statistical information covering the broad field of American education from kindergarten through graduate school. The "Mini-Digest" is designed as an easy reference for materials found in much greater detail in the…

  10. Fibrous mini-collagens in hydra nematocysts.

    Science.gov (United States)

    Holstein, T W; Benoit, M; Herder, G V; David, C N; Wanner, G; Gaub, H E

    1994-07-15

    Nematocysts (cnidocysts) are exocytotic organelles found in all cnidarians. Here, atomic force microscopy and field emission scanning electron microscopy reveal the structure of the nematocyst capsule wall. The outer wall consists of globular proteins of unknown function. The inner wall consists of bundles of collagen-like fibrils having a spacing of 50 to 100 nanometers and cross-striations at intervals of 32 nanometers. The fibrils consist of polymers of "mini-collagens," which are abundant in the nematocysts of Hydra. The distinct pattern of mini-collagen fibers in the inner wall can provide the tensile strength necessary to withstand the high osmotic pressure (15 megapascals) in the capsules.

  11. Concerning production and decay of mini black holes

    CERN Document Server

    Hajdukovic, D

    2007-01-01

    In the next few years, theories predicting possibility to create mini black holes will be tested at CERN. Either experimental verification or rejection of these theories is of great scientific importance. There is a large consensus that, if successfully created, these short living mini black holes will decay through thermal (Hawking's) radiation. In the present comment we point out, that under assumption of the gravitational repulsion between matter and antimatter (in short we call it antigravity), thermal radiation may be dominated by a non-thermal radiation (being the consequence of pair creation from the vacuum, by gravitational field, which in the case of antigravity, pushes particles and antiparticles in opposite directions). Thus, the eventual creation of mini black holes may turn to be an unexpected opportunity to test the existence of antigravity.

  12. The 'mini brain' appearance of plasmacytoma in the appendicular skeleton

    Energy Technology Data Exchange (ETDEWEB)

    Subhas, N.; Sundaram, M. [Cleveland Clinic, Department of Diagnostic Radiology, Cleveland, OH (United States); Bauer, T.W. [Cleveland Clinic, Department of Anatomic Pathology, Cleveland, OH (United States); Joyce, M.J. [Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH (United States)

    2008-08-15

    We report on the case of a 70-year-old woman presenting with right hip pain. Radiographs of the right hip demonstrated a well-defined large lytic lesion in the proximal right femur, with prominent trabeculae situated peripherally and extending into the lesion in a 'spoke-wheel' pattern. Magnetic resonance imaging (MRI) demonstrated solid enhancing marrow-replacing lesion, with intervening linear nonenhancing areas of low T2 signal intensity. The MRI appearance resembled that of a small brain or 'mini brain'. Biopsy specimen demonstrated predominantly mature plasma cells, with occasional admixed immature forms. A diagnosis of plasmacytosis, consistent with myeloma, was made. This case illustrates a rare but seemingly characteristic 'mini brain' appearance of plasmacytoma, which, to date, has only been reported in the spine and has not been observed in other bony lesions. (orig.)

  13. Evaluation of mini super computers for nuclear design applications

    International Nuclear Information System (INIS)

    Altomare, S.; Baradari, F.

    1987-01-01

    The evolution of the mini super computers will force changes from the current environment of performing nuclear design calculations on mainframe computers (such as a CRAY) to mini super computers. This change will come about for a number of reasons. First, the mini super computers currently available in the marketplace offer the power and speed comparable to mainframes and can provide the capability to support highly computer intensive calculations. Second, the equipment is physically smaller and can easily be installed and operated without extensive investments in facilities and operations support. Third, the computer capacity can be acquired with as much needed memory, disk, and tape capacity as may be needed. Another reasons is that the performance/cost ratio has increased drastically as hardware costs have decreased. A study was conducted at the Westinghouse Commercial Nuclear Fuel Division (CNFD) to evaluate the mini super computers for use in nuclear core design. As a result of this evaluation, Westinghouse CNFD is offering a combined hardware/software technology transfer package for core design. This package provides the utility designer with a totally dedicated mini super computer comparable in speed to the CRAY 1S with sufficient capacity for a sizable design group to perform the engineering activities related to nuclear core design and operations support. This also assures the utility of being totally compatible with the CNFD design codes, thus assuring total update compatibility

  14. Neurospora crassa tox-1 Gene Encodes a pH- and Temperature-Tolerant Mini-Cellulase.

    Science.gov (United States)

    Xiao, Yue; Zhang, Qiongsi; Luo, Yiquan; Zhang, Ying; Luo, Xi; Wang, Yuchuan; Cao, Weiguo; Pinto, Vito De; Liu, Qiuyun; Li, Gang

    2016-06-15

    Cellulases that endure extreme conditions are essential in various industrial sectors. This study reports a mini-cellulase gene tox-1 from Neurospora crassa. The gene tox-1 was cloned in Escherichia coli after chimerization with the YebF gene and substitutions of certain isoleucine and valine with leucine residues. The yeast transformants could grow on rice straw-agar medium. The 44-amino acid peptide and its two mutant variants displayed potent cellulase activities in Congo Red assay and enzymatic assays. Conservative replacements with leucine have substantially increased the stabilities and half-lives of the peptides at alkaline pH and low and high temperatures and also the tolerance to organic solvents and surfactants, on the basis of activities toward cellose. The small size of the mini-cellulase would allow for commercially viable automatic chemical peptide synthesis. This work suggests that conservative leucine replacements may serve as a general strategy in the engineering of more robust enzymes with special features with little loss of activities.

  15. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation of communi......INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...

  16. Injuries in Japanese Mini-Basketball Players During Practices and Games

    Science.gov (United States)

    Kuzuhara, Kenji; Shibata, Masashi; Uchida, Ryo

    2016-01-01

    Context: Mini-basketball is one of the most popular junior sports in Japan. Mini-basketball–related injuries may increase because of early specialization. However, no reports have been published to date concerning basketball injuries in children younger than 12 years of age. Objective: To prospectively study the incidence, sites, types, and mechanisms of injuries in mini-basketball teams. Design: Descriptive epidemiology study. Setting: Mini-basketball teams in Kobe, Japan. Patients or Other Participants: A total of 95 players in 7 community-based mini-basketball club teams (age range, 9 through 12 years). Main Outcome Measure(s): Data on all practice and game injuries for the 2013–2014 season were collected using an injury report form. Injury rates were calculated according to site, type, and mechanism. Results: The overall injury rate was 3.83 per 1000 athlete-hours (AHs). The game injury rate (12.92/1000 AHs) was higher than the practice injury rate (3.13/1000 AHs; P basketball players. The high practice injury rate in this study may be due to specific factors related to growth, such as individual differences in height, or to skills, such as inexperience in ball handling. PMID:27922287

  17. Gender and Self-Employment: The Role of Mini-Companies

    Science.gov (United States)

    Johansen, Vegard

    2016-01-01

    Purpose: The purpose of this paper is to evaluate to what degree participation in mini-companies impact young women and men with regard to the perceived desirability and perceived feasibility of self-employment. The Company Programme (CP) is the largest mini-company scheme in European secondary school. Design/methodology/approach: The data derived…

  18. Afrique : ressources minières, environnement et gouvernance ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    25 janv. 2011 ... ils regorgent de richesses inouïes », assure Bonnie Campbell, directrice du Groupe de recherche sur les activités minières en Afrique (GRAMA) et titulaire de la Chaire C.-A. Poissant de recherche sur la gouvernance et l'aide au développement, faisant référence aux ressources minières et pétrolières dont ...

  19. MiniDLNA_tweaker : Aplicació per configurar i previsualitzar el servidor MiniDLNA per a GNU/Linux

    OpenAIRE

    Martínez Lloveras, Jordi

    2013-01-01

    L'aplicació MiniDLNA per a GNU/Linux és un servidor lleuger que compleix els estàndards DLNA/UPnP configurable a través d'un simple arxiu de text, això la fa ideal per al propòsit d'implantació d'un servidor que ofereixi els continguts a tots els dispositius que compleixin els estàndards esmentats. La aplicación MiniDLNA para GNU/Linux es un servidor ligero que cumple los estándares DLNA/UPnP configurable a través de un simple archivo de texto, esto la hace ideal para el propósito de impla...

  20. Agreement between clinical and MINI diagnoses in outpatients with mood and anxiety disorders

    NARCIS (Netherlands)

    Verhoeven, F. E. A.; Swaab, L. S. M. A.; Carlier, I. V. E.; van Hemert, A. M.; Zitman, F. G.; Ruhé, H. G.; Schoevers, R. A.; Giltay, E. J.

    2017-01-01

    Background: Standardized Diagnostic Interviews (SDIs) such as the Mini International Neuropsychiatric Interview (MINI) are widely used to systematically screen for psychiatric disorders in research. To support generalizability of results to clinical practice, we assessed agreement between the MINI

  1. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    Science.gov (United States)

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  2. The Galactic Centre Mini-Spiral with CARMA

    Science.gov (United States)

    Kunneriath, D.; Eckart, A.; Vogel, S. N.; Teuben, P.; Muzic, K.; Schodel. R.; Garcia-Marin, M.; Moultaka, J.; Staguhn, J.; Straubmeier, C.; hide

    2012-01-01

    The Galactic centre mini-spiral region is a mixture of gas and dust with temperatures ranging from a few hundred K to 10(exp 4) K. We report results from 1.3 and 3mm radio interferometric observations of this region with CARMA, and present a spectral index map of this region. We find a range of emission mechanisms in the region, including the inverted synchrotron spectrum of Sgr A*, free-free emission from the mini-spiral arms, and a possible dust emission contribution indicated by a positive spectral index.

  3. Photovoltaic energy mini-generation: Future perspectives for Portugal

    International Nuclear Information System (INIS)

    Carvalho, Duarte; Wemans, Joao; Lima, Joao; Malico, Isabel

    2011-01-01

    This paper evaluates the benefits of developing the mini-generation PV market in Portugal. It presents the legal framework and current status of the Portuguese PV electricity sector, and compares the country to other European nations: France, Germany, Greece, Italy, Spain and the United Kingdom. A model that combines PVGIS with a self-developed financial tool is used to assess the feasibility of a 150 kW mini-generation system using five different technologies: fixed mount, single-axis tracking, double-axis tracking, low concentration and medium concentration (MCPV). The profitability of the mini-generation systems in the seven countries studied is calculated and compared. According to this analysis, MCPV and, of the conventional technologies, the single-axis tracking systems are the most profitable technologies. Despite the attractiveness of the current Portuguese feed-in tariffs and of the abundant solar resource, investors are discouraged and the country's PV market is far from mature. Specific mini-generation regulations should focus on a fast and transparent licensing procedure and should promote the access to financing. This would attract new investments, which would result in the growth of the PV electricity produced, and would help Portugal to meet its European Union Renewable Energy targets. - Highlights: → This work promotes the development of a mini-generation PV market in Portugal. → The Portuguese current status and legal framework is compared to other EU countries. → The profitability of 5 different PV technologies is compared for 7 European countries. → The Portuguese growth potential for PV energy is still big. → Portugal, due to its radiation levels, presents excellent investment opportunities.

  4. Validation of the Mini-OAKHQOL for use in patients with osteoarthritis in Spain.

    Science.gov (United States)

    Gonzalez Sáenz de Tejada, Marta; Bilbao, Amaia; Herrera, Carmen; García, Lidia; Sarasqueta, Cristina; Escobar, Antonio

    2017-08-01

    The Mini-Osteoarthritis Knee and Hip Quality of Life (Mini-OAKHQOL) questionnaire osteoarthritis is specific to individuals with knee or hip osteoarthritis. The objective of this study was to perform a validation of the Mini-OAKHQOL for use in Spain in terms of its psychometric properties of reliability, validity and responsiveness. Patients with osteoarthritis from the waiting list for a joint replacement completed the OAKHQOL, Short Form 36 Health Survey and Western Ontario and McMaster Universities Osteoarthritis Index. Reliability was assessed in terms of internal consistency and test-retest data, and convergent validity using Spearman's correlation coefficient. Structural validity was investigated by confirmatory factor analysis, and Rasch analysis was used to examine the unidimensionality of the scales. Responsiveness was assessed by calculating effect sizes. Confirmatory factor analysis confirmed the five-factor model, and the results of the Rasch analyses supported the unidimensionality assumption, with infit and outfit statistics. Cronbach's alpha ranged from 0.76 to 0.89 for all except the social dimensions. Statistically significant differences were observed between patients with different degrees of disease severity on all dimensions. There was convergent validity among dimensions expected to be correlated. The OAKHQOL questionnaire showed good responsiveness, with large changes for all dimensions apart from the two social dimensions, which had small effect sizes. Results of the study support the view that the Spanish version of the Mini-OAKHQOL questionnaire is a valid instrument to measure health-related quality of life in patients with osteoarthritis of the lower limb.

  5. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA in a Mexican Population

    Directory of Open Access Journals (Sweden)

    María Fernanda Bernal-Orozco

    2018-04-01

    Full Text Available Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy or 1 (healthy, and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016, were invited to participate. The survey was administered in two rounds (test and retest with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC, and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant. The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001, and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885. It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  6. Paradigm shifts in orthodontic treatment with mini-implant anchorage

    Directory of Open Access Journals (Sweden)

    Johnny Joung-Lin Liaw

    2015-01-01

    Full Text Available After the applications of mini-implant anchorage, the envelope of orthodontic treatment was expanded and some treatment modes were changed because of more predictable tooth movement with empowered anchorage. The author tried to share his experience of TADs applications for clarifying the paradigm shifts of orthodontic treatment assisted with the mini-implant anchorage.

  7. Mini-Sniffer III on Lakebed with Ground Support Crew

    Science.gov (United States)

    1976-01-01

    The third version of the Mini-Sniffer remotely-piloted research vehicle on Rogers Dry Lake, adjacent to NASA's Dryden Flight Research Center, Edwards, California. The futuristic-looking ground crew are in white, self-contained suits, because the engine on this third version of the Mini-Sniffer was powered by hydrazine, which is a very hazardous material. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the

  8. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Science.gov (United States)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement

  9. Recommended safety objectives, principles and requirements for mini-reactors

    International Nuclear Information System (INIS)

    1991-05-01

    Canadian and international publications containing objectives, principles and requirements for the safety of nuclear facilities in general and nuclear power plants in particular have been reviewed for their relevance to mini-reactors. Most of the individual recommendations, sometimes with minor wording changes, are applicable to mini-reactors. However, some prescriptive requirements for the shutdown, emergency core cooling and containment systems of power reactors are considered inappropriate for mini-reactors. The Advisory Committee on Nuclear Safety favours a generally non-prescriptive approach whereby the applicant for a mini-reactor license is free to propose any means of satisfying the fundamental objectives, but must convince the regulatory agency to that effect. To do so, a probabilistic safety assessment (PSA) would be the favoured procedure. A generic PSA for all mini-reactors of the same design would be acceptable. Notwithstanding this non-prescriptive approach, the ACNS considers that it would be prudent to require the existence of at least one independent shutdown system and two physically independent locations from which the reactor can be shut down and the shutdown condition monitored, and to require provision for an assumed loss of integrity of the primary cooling system's boundary unless convincing arguments to the contrary are presented. The ACNS endorses in general the objectives and fundamental principles proposed by the interorganizational Small Reactor Criteria working group, and intends to review and comment on the documents on specific applications to be issued by that working group

  10. Cryopreservation of boar semen in mini- and maxi-straws.

    Science.gov (United States)

    Bwanga, C O; de Braganca, M M; Einarsson, S; Rodriguez-Martinez, H

    1990-10-01

    Split ejaculates from four boars were frozen with a programmable freezing machine, in mini- (0.25 ml) and maxi- (5 ml) plastic straws with an extender at either acidic (6.3) or alkaline (7.4) pH. Glycerol (3%) was used as cryoprotectant. The freezing of the semen was monitored by way of thermocouples placed in the straws. Post-thaw motility and acrosome integrity were evaluated; the latter using phase contrast microscopy, eosin-nigrosin stain and electron microscopy. Post-thaw sperm motility was significantly higher when semen was frozen in mini-straws than in maxi-straws. For the mini-straws, the motility was better when semen was exposed to an acidic environment during freezing, but this beneficial effect of the low extracellular pH was not evident when maxi-straws were thawed. The motility of the spermatozoa diminished significantly during the thermoresistance test (0 h and 2 h time) at 37 degrees C in a similar way for both straws and extracellular pH's. The freezing procedure, no matter the extracellular pH, did not cause major acrosomal damages, but significantly more normal apical ridges were present in the mini-straws than in the maxi-straws. This in vitro evaluation indicated that the freezing method employed was better for mini- than for maxi-straws since the freezing of the 5 ml volumes was not homogeneous, due to the large section area between the surface and the core of the straw.

  11. A mini-microscope for in situ monitoring of cells†‡

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  12. Impact of Mini-drone based Video Surveillance on Invasion of Privacy

    OpenAIRE

    Korshunov, Pavel; Bonetto, Margherita; Ebrahimi, Touradj; Ramponi, Giovanni

    2015-01-01

    An increase in adoption of video surveillance, affecting many aspects of daily lives, raises public concern about an intrusion into individual privacy. New sensing and surveillance technologies, such as mini-drones, threaten to eradicate boundaries of private space even more. Therefore, it is important to study the effect of mini-drones on privacy intrusion and to understand how existing protection privacy filters perform on a video captured by a mini-drone. To this end, we have built a publi...

  13. NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2016-03-01

    Full Text Available Abstract NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE. Research of UMo fuel for research reactor has been developing  right now. The fuel of  research reactor used is uranium low enrichment with high density. For supporting the development of fuel, an assessment of mini fuel in the RSG-GAS core was performed. The mini fuel are U7Mo-Al and U6Zr-Al with densitis of 7.0gU/cc and 5.2 gU/cc, respectively. The size of both fuel are the same namely 630x70.75x1.30 mm were inserted to the 3 plates of dummy fuel. Before being irradiated in the core, a calculation for safety analysis  from neutronics and thermohydrolics aspects were required. However, in this paper will discuss safety analysis of the U7Mo-Al and U6Zr-Al mini fuels from neutronic point of view.  The calculation was done using WIMSD-5B and Batan-3DIFF code. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. Power density of U7Mo-Al mini fuel bigger than U6Zr-Al fuel.   Key words: mini fuel, neutronics analysis, reactor core, safety analysis   Abstrak ANALISIS NEUTRONIK ELEMEN BAKAR UJI MINI DI TERAS RSG-GAS. Penelitian tentang bahan bakar UMo untuk reaktor riset terus berkembang saat ini. Bahan bakar reaktor riset yang digunakan adalah uranium pengkayaan rendah namun densitas tinggi.  Untuk mendukung pengembangan bahan bakar dilakukan uji elemen bakar mini di teras reakror RSG-GAS dengan tujuan menentukan jumlah siklus di dalam teras sehingga tercapai fraksi bakar maksimum. Bahan bakar yang diuji adalah U7Mo-Al dengan densitas 7,0 gU/cc dan U6Zr-Al densitas 5,2 gU/cc. Ukuran kedua bahan bakar uji tersebut adalah sama 630x70,75x1,30 mm dimasukkan masing masing kedalam 3 pelat dummy bahan bakar. Sebelum diiradiasi ke dalam teras reaktor maka perlu dilakukan perhitungan keselamatan baik secara neutronik maupun termohidrolik. Dalam makalah ini

  14. A DNA Mini-Barcoding System for Authentication of Processed Fish Products.

    Science.gov (United States)

    Shokralla, Shadi; Hellberg, Rosalee S; Handy, Sara M; King, Ian; Hajibabaei, Mehrdad

    2015-10-30

    Species substitution is a form of seafood fraud for the purpose of economic gain. DNA barcoding utilizes species-specific DNA sequence information for specimen identification. Previous work has established the usability of short DNA sequences-mini-barcodes-for identification of specimens harboring degraded DNA. This study aims at establishing a DNA mini-barcoding system for all fish species commonly used in processed fish products in North America. Six mini-barcode primer pairs targeting short (127-314 bp) fragments of the cytochrome c oxidase I (CO1) DNA barcode region were developed by examining over 8,000 DNA barcodes from species in the U.S. Food and Drug Administration (FDA) Seafood List. The mini-barcode primer pairs were then tested against 44 processed fish products representing a range of species and product types. Of the 44 products, 41 (93.2%) could be identified at the species or genus level. The greatest mini-barcoding success rate found with an individual primer pair was 88.6% compared to 20.5% success rate achieved by the full-length DNA barcode primers. Overall, this study presents a mini-barcoding system that can be used to identify a wide range of fish species in commercial products and may be utilized in high throughput DNA sequencing for authentication of heavily processed fish products.

  15. Mini mental state examination

    DEFF Research Database (Denmark)

    Kørner, Ejnar Alex; Lauritzen, Lise; Wang, August

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...... the severity of dementia disorders. Udgivelsesdato: 2008-Feb-25...

  16. Implementing the undergraduate mini-CEX: a tailored approach at Southampton University.

    Science.gov (United States)

    Hill, Faith; Kendall, Kathleen; Galbraith, Kevin; Crossley, Jim

    2009-04-01

    The mini-clinical evaluation exercise (mini-CEX) is widely used in the UK to assess clinical competence, but there is little evidence regarding its implementation in the undergraduate setting. This study aimed to estimate the validity and reliability of the undergraduate mini-CEX and discuss the challenges involved in its implementation. A total of 3499 mini-CEX forms were completed. Validity was assessed by estimating associations between mini-CEX score and a number of external variables, examining the internal structure of the instrument, checking competency domain response rates and profiles against expectations, and by qualitative evaluation of stakeholder interviews. Reliability was evaluated by overall reliability coefficient (R), estimation of the standard error of measurement (SEM), and from stakeholders' perceptions. Variance component analysis examined the contribution of relevant factors to students' scores. Validity was threatened by various confounding variables, including: examiner status; case complexity; attachment specialty; patient gender, and case focus. Factor analysis suggested that competency domains reflect a single latent variable. Maximum reliability can be achieved by aggregating scores over 15 encounters (R = 0.73; 95% confidence interval [CI] +/- 0.28 based on a 6-point assessment scale). Examiner stringency contributed 29% of score variation and student attachment aptitude 13%. Stakeholder interviews revealed staff development needs but the majority perceived the mini-CEX as more reliable and valid than the previous long case. The mini-CEX has good overall utility for assessing aspects of the clinical encounter in an undergraduate setting. Strengths include fidelity, wide sampling, perceived validity, and formative observation and feedback. Reliability is limited by variable examiner stringency, and validity by confounding variables, but these should be viewed within the context of overall assessment strategies.

  17. A high-resolution mini-microscope system for wireless real-time monitoring.

    Science.gov (United States)

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2017-09-04

    Compact, cost-effective and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless mini-microscope with resolution up to 2592 × 1944 pixels and speed up to 90 fps. The mini-microscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed mini-microscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 hours. In addition, the mini-microscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the mini-microscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed mini-microscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high resolution mini-microscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  18. PARTICIPATION OF MINI-BASKETBALL PLAYERS DURING SMALL-SIDED COMPETITIONS

    Directory of Open Access Journals (Sweden)

    M\\u00AA Isabel Pi\\u00F1ar

    2009-01-01

    Full Text Available This study presents the differences of competition between mini-basketball with the traditional rules (5-a-side and minibasket with rule modifications (3-a-side such as: reduced number of players on court, compulsory participation in 2 of the match's 4 periods, reduced court size, placing the free throw line at 3m from the basket, and including a three-point line. The sample that was selected included 47 mini-basketball players, and the study was carried out using a quasi-experimental design without a control group. The aim was to determine the effect of rule modifications on the participation of the player with the ball. It was demonstrated that the degree of individual participation is greater in mini-basketball with modified rules.

  19. Two mini-preparation protocols to DNA extraction from plants with ...

    African Journals Online (AJOL)

    Were standardized two previously reported standard plant DNA extraction methods, but improved them on mini preparations to use the samples for population genetic analysis. The combination of CTAB lysis procedure-solvent extraction and DNA column purification (DNeasy plant mini kit modification) enables a faster and ...

  20. High-flying Mini-Sniffer RPV - Mars bound

    Science.gov (United States)

    Reed, R. D.

    1978-01-01

    The Mini-Sniffer is a small unmanned survey aircraft developed by NASA to conduct turbulence and atmospheric pollution measurements from ground level to an altitude of 90,000 ft. Carrying a 25-lb air sampling apparatus, the Mini-Sniffer typically cruises for one hour at 70,000 ft before being remotely piloted back to earth. A hydrazine monopropellant engine powers the craft, while a PCM telemetering system and a radar transponder provide control functions. Development of a high-performance low-Reynolds-number airfoil could make the research craft suitable for a low-altitude terrain-following mission on Mars.

  1. The Mini-Social Phobia Inventory: psychometric properties in an adolescent general population sample.

    Science.gov (United States)

    Ranta, Klaus; Kaltiala-Heino, Riittakerttu; Rantanen, Päivi; Marttunen, Mauri

    2012-07-01

    Onset of social phobia (SP) typically occurs in adolescence. Short screening instruments for its assessment are needed for use in primary health and school settings. The 3-item Mini-Social Phobia Inventory (SPIN) has demonstrated effectiveness in screening for generalized SP (GSP) in adults. This study examined the psychometrics of the Mini-SPIN in an adolescent general population sample. Three hundred fifty adolescents aged 12 to 17 years were clinically interviewed using the Schedule for Affective Disorders and Schizophrenia for School-Age Children-Present and Lifetime Version for identification of SP and other Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Axis I disorders, blind to their Mini-SPIN status. Associations between SP; subclinical SP; other anxiety, depressive, and disruptive disorders; and Mini-SPIN scores were examined, and diagnostic efficiency statistics were calculated. The association between Mini-SPIN scores and the generalized subtype of SP was also examined. As in adults, the Mini-SPIN items differentiated subjects with SP from those without. A score of 6 points or greater was found optimal in predicting SP with a sensitivity of 86%, specificity of 84%, and positive and negative predictive values of 26% and 99%. The Mini-SPIN also possessed discriminative validity, as scores were higher for adolescents with SP than they were for those with depressive, disruptive, and other anxiety disorders. The Mini-SPIN was also able to differentiate adolescents with GSP from the rest of the sample. The Mini-SPIN has good psychometrics for screening SP in adolescents from general population and may have value in screening for GSP. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Tourette Syndrome: A Mini-Review

    Directory of Open Access Journals (Sweden)

    Michal Novotny

    2018-03-01

    Full Text Available The purpose of this mini-review is to provide the latest information on epidemiology, pathophysiology, diagnosis, and treatment of Tourette syndrome (TS. The authors conducted a literature search of available sources describing the issue of tic disorders with special focus on TS and made a comparison and evaluation of relevant findings. The results of this mini-review indicate that TS is a complex disorder, which has a significant impact on the quality of life of both the patients and his/her family. Therefore, early and proper diagnosis and treatment are necessary in order to reduce or even eliminate both symptoms and social burden of the patient. This requires a multidisciplinary management approach in order to meet the patients’ special needs. Future research should focus on neuroimaging, new neurotransmitter targets, in functional neurosurgery, as well as the effect of non-pharmacological psychotherapies for these people.

  3. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC) among a heterogeneous sample of long-term cancer survivors: a cross-sectional study.

    Science.gov (United States)

    Zucca, Alison; Lambert, Sylvie D; Boyes, Allison W; Pallant, Julie F

    2012-05-20

    The mini-Mental Adjustment to Cancer Scale (mini-MAC) is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. RUMM 2030 was used to analyse the mini-MAC data (n=851). Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI), response format, local dependency, targeting, item bias (or differential item functioning -DIF), and dimensionality. For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales - Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of adaptive and maladaptive coping, extensive modifications were

  4. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC among a heterogeneous sample of long-term cancer survivors: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Zucca Alison

    2012-05-01

    Full Text Available Abstract Background The mini-Mental Adjustment to Cancer Scale (mini-MAC is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. Methods RUMM 2030 was used to analyse the mini-MAC data (n=851. Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI, response format, local dependency, targeting, item bias (or differential item functioning -DIF, and dimensionality. Results For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales – Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. Conclusions The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of

  5. Psychometric evaluation of a Dutch version of the Mini PAS-ADD for assessing psychiatric disorders in adults with different levels of intellectual disability.

    Science.gov (United States)

    Janssen, R; Maes, B

    2013-08-01

    People with intellectual disabilities (ID) have an increased vulnerability to develop psychiatric problems. Moreover, the early recognition and the accurate diagnosis of psychiatric disorders in the population of persons with ID are challenging. A Dutch version of the Mini PAS-ADD, which is a screening instrument for identification of mental health problems in people with ID, was evaluated in terms of internal consistency, interinformant reliability, item grouping and criterion validity based on a large-scale random sample (n = 377) and a clinical sample (n = 99) of adults with ID. The Dutch version of the Mini PAS-ADD showed moderate internal consistency, and moderate concordance among informants. Both aspects of the reliability were comparable for different levels of ID. A factor analysis largely confirmed the scale structure. Concurrent validity with the Reiss Screen for Maladaptive Behavior was high for the Depression, Psychosis and Autism scale. The outcome of the criterion-validity analysis indicated high specificity. The sensitivity for specific psychiatric disorders by the corresponding scales was moderate, but the general sensitivity for the presence of psychopathology on the basis of any of the scales was satisfying. The present research reconfirmed the use of the Mini PAS-ADD as a primary screening device for the identification of mental health problems among people with ID. © 2012 The Authors. Journal of Intellectual Disability Research © 2012 John Wiley & Sons Ltd, MENCAP & IASSID.

  6. A preliminary study of the mini-mental state examination in a Spanish child population.

    Science.gov (United States)

    Rubial-Alvarez, Sandra; Machado, María-Clara; Sintas, Elena; de Sola, Susana; Böhm, Peter; Peña-Casanova, Jordi

    2007-11-01

    The Mini-Mental State Examination is one of the most widely used screening tests for the adult population in daily neurologic practice. The aim of this study was to describe and to analyze the results of the Mini-Mental State Examination administered to Spanish children and to assess the relationship between Mini-Mental State Examination scores and the child's mental age/intelligence quotient. The study population included 181 children whose ages ranged between 4 and 12 years. The neuropsychologic battery consisted of the Mini-Mental State Examination and Kaufman Brief Intelligence Test. Percentiles were obtained for the Mini-Mental State Examination total score according to age ranges. Performance gradually increased from 4 to 10 years of age when a plateau in the total Mini-Mental State Examination score was reached. At the age of 6 years, results exceeded 24 on average. Pairwise mean comparisons showed statistically significant differences between the age groups (P Mini-Mental State Examination score correlated significantly with the child's chronologic (r = 0.80, P mental (r = 0.76, P Mini-Mental State Examination in a Spanish child population as well as a first step for the assessment of the usefulness of this instrument as a cognitive screening tool for children's development.

  7. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  8. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Perevalov, Denis [Univ. of Alabama, Tuscaloosa, AL (United States)

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for vμ → ve neutrino oscillations at Δm2 ~ 1 eV2 using an intense neutrino flux with an average energy Ev ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current π0, charged current quasi-elastic (CCQE), charged current π+, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis

  9. Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Harper, Meg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-03-01

    This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of the discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.

  10. Pengaruh Permaianan Bola Voli Mini Terhadap Peningkatan Kebugaran Jasmani Pecandu Narkoba

    Directory of Open Access Journals (Sweden)

    Kurnia Rismaningtyas

    2016-10-01

    Full Text Available This study aims to answer the following questions: 1 the influence of a volleyball mini-game model to increase physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. 2 How big contribution volleyball mini model of the game due to the improvement of physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. . T test results obtained tcount for data post test of 2,420 with significance 0.022 <0.05, which means that the average physical fitness between the experimental and control groups after treatment was significantly different. Judging from an average of 35.79 in the experimental group and the control group of 32.92 indicates that the level of physical fitness of women prisoners IIA class drug addict treatment Semarang made a game of volleyball mini-game is better than that do not follow the game of volleyball mini , In the experimental group increased physical fitness significantly, evident from the value t = 6.541 with a significance value of 0.000 <0.05. It was concluded that: 1 Model mini volleyball games that do can improve the physical fitness of inmates in prisons Women Class II A Semarang. 2 In the experimental group showed that the model of a volleyball mini-game has a significant influence on the improvement of physical fitness on female inmates in prison Women drug addicts Class II A Semarang.

  11. Mini-guide til DGNB

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Guiden giver et kort indblik i formålet med de enkelte kriterier i en DGNB- bæredygtighedsvurdering, samt i hvordan der kan måles på kriterierne. Mini-guiden tager afsæt i systemet for certificering af Nybyggede kontor-og erhvervsbyggerier, som er det første og grundlæggende system i DGNB, som al...

  12. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics

    Directory of Open Access Journals (Sweden)

    El-Say Khalid M.

    2015-12-01

    Full Text Available This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1, swelling pressure of the superdisintegrant (X2, and the surface area of Aerosil as a glidant (X3. Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for preand post-compression characteristics. The prepared ODmini- tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2 and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  13. Performance Optimization of Alternative Lower Global Warming Potential Refrigerants in Mini-Split Room Air Conditioners

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [ORNL; Abdelaziz, Omar [ORNL; Shrestha, Som S [ORNL

    2017-01-01

    Oak Ridge National laboratory (ORNL) recently conducted extensive laboratory, drop-in investigations for lower Global Warming Potential (GWP) refrigerants to replace R-22 and R-410A. ORNL studied propane, DR-3, ARM-20B, N-20B and R-444B as lower GWP refrigerant replacement for R-22 in a mini-split room air conditioner (RAC) originally designed for R-22; and, R-32, DR-55, ARM-71A, and L41-2, in a mini-split RAC designed for R-410A. We obtained laboratory testing results with very good energy balance and nominal measurement uncertainty. Drop-in studies are not enough to judge the overall performance of the alternative refrigerants since their thermodynamic and transport properties might favor different heat exchanger configurations, e.g. cross-flow, counter flow, etc. This study compares optimized performances of individual refrigerants using a physics-based system model tools. The DOE/ORNL Heat Pump Design Model (HPDM) was used to model the mini-split RACs by inputting detailed heat exchangers geometries, compressor displacement and efficiencies as well as other relevant system components. The RAC models were calibrated against the lab data for each individual refrigerant. The calibrated models were then used to conduct a design optimization for the cooling performance by varying the compressor displacement to match the required capacity, and changing the number of circuits, refrigerant flow direction, tube diameters, air flow rates in the condenser and evaporator at 100% and 50% cooling capacities. This paper compares the optimized performance results for all alternative refrigerants and highlights best candidates for R-22 and R-410A replacement.

  14. Mini-Exame do Estado Mental: características psicométricas em idosos ambulatoriais Mini-Mental State Examination: psychometric characteristics in elderly outpatients

    Directory of Open Access Journals (Sweden)

    Roberto A Lourenço

    2006-08-01

    Full Text Available OBJETIVO: Avaliar as características de medida do Mini-Exame do Estado Mental em idosos atendidos em um ambulatório geral. MÉTODOS: O total de 303 indivíduos (>65 anos foi submetido à avaliação geriátrica com vários instrumentos, inclusive o Mini-Exame do Estado Mental. Foram calculadas a sensibilidade, a especificidade, os valores preditivos positivo e negativo e a curva ROC. RESULTADOS: A sensibilidade, a especificidade, os valores preditivos positivo e negativo e a área sob a curva ROC foram 80,8%, 65,3%, 44,7%, 90,7% e 0,807, respectivamente (ponto de corte 23/24. O melhor ponto de corte para indivíduos analfabetos foi 18/19 (sensibilidade =73,5%; especificidade =73,9%, e para aqueles com instrução escolar foi 24/25 (sensibilidade =75%; especificidade =69,7%. CONCLUSÕES: Para o rastreamento cognitivo de idosos atendidos em ambulatórios gerais pelo Mini-Exame do Estado Mental, a escolaridade deverá ser considerada para a adoção do ponto de corte mais adequado.OBJECTIVE: To assess the psychometric characteristics of the Mini-Mental State Examination in elderly outpatients who seek primary health care. METHODS: A total of 303 subjects (>65 years underwent comprehensive geriatric assessment with functional tools, including Mini-Mental State Examination. Sensitivity, specificity, positive predictive value, negative predictive value, and ROC curve were calculated. RESULTS: Sensitivity, specificity, positive and negative predictive values, and area under ROC curve were 80.8%, 65.3%, 44.7%, 90.7% and 0.807 respectively (cutoff point =23/24. The best cutoff point for illiterate was 18/19 (sensitivity =73.5%; specificity =73.9%; and for literate was 24/25 (sensitivity =75%; specificity =69.7%. CONCLUSIONS: While screening elderly outpatients for dementia, schooling must be considered in the choice of the best cutoff point in the Mini-Mental State Examination.

  15. Entrepreneur and Establishment of a Mini Hotel in XiChang, China

    OpenAIRE

    Hu, Mingsong

    2013-01-01

    Mini Hotel, is a new hotel will be opened in China in this year. I and 4 of my friends will be the shareholders of this Mini Hotel. The hotel is planned to be operating from the autumn of 2013. Now, everything in this thesis is on process. The main objective of this thesis was to draft an effective approach to ensure this is a right plan which is worth to invest. By using benchmarking and SWOT analysis we defined the strength and weakness of this Mini Hotel business plan. This thesis will ...

  16. Model of competitive mini-hotel project life cycle

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2014-01-01

    Having examined the situation in the hotel market of the city of Kharkov (Ukraine), it was found that one of the major shortcomings in the activities of mini-hotels is mediocre attitude towards customers, lack of proper attention and poor services. In this regard, there is the need to create a mini-hotel, the most important mission of which would be a genuine concern for guests and their comfort, as well as providing unique services of the highest class.For the success of this mission, it is ...

  17. Lexicography Problems and Theoretical Interpretation of Mini-Dictionaries

    Directory of Open Access Journals (Sweden)

    Jūratė Butkienė

    2011-04-01

    Full Text Available The article deals with principles of the word selection while compiling a mini-dictionary (containing a minimal number of words as well as with criteria and theoretical background thereof. The development of such principles is being analysed in Lithuania and abroad. The word selection while compiling a mini-dictionary of German language dedicated to the students of Civil engineering is being detailed. Furthermore, the article provides recommendations. The word selection has to be based on the linguistic statistics and on the thorough text analysis.

  18. Feasibility of a multiple-choice mini mental state examination for chronically critically ill patients.

    Science.gov (United States)

    Miguélez, Marta; Merlani, Paolo; Gigon, Fabienne; Verdon, Mélanie; Annoni, Jean-Marie; Ricou, Bara

    2014-08-01

    Following treatment in an ICU, up to 70% of chronically critically ill patients present neurocognitive impairment that can have negative effects on their quality of life, daily activities, and return to work. The Mini Mental State Examination is a simple, widely used tool for neurocognitive assessment. Although of interest when evaluating ICU patients, the current version is restricted to patients who are able to speak. This study aimed to evaluate the feasibility of a visual, multiple-choice Mini Mental State Examination for ICU patients who are unable to speak. The multiple-choice Mini Mental State Examination and the standard Mini Mental State Examination were compared across three different speaking populations. The interrater and intrarater reliabilities of the multiple-choice Mini Mental State Examination were tested on both intubated and tracheostomized ICU patients. Mixed 36-bed ICU and neuropsychology department in a university hospital. Twenty-six healthy volunteers, 20 neurological patients, 46 ICU patients able to speak, and 30 intubated or tracheostomized ICU patients. None. Multiple-choice Mini Mental State Examination results correlated satisfactorily with standard Mini Mental State Examination results in all three speaking groups: healthy volunteers: intraclass correlation coefficient = 0.43 (95% CI, -0.18 to 0.62); neurology patients: 0.90 (95% CI, 0.82-0.95); and ICU patients able to speak: 0.86 (95% CI, 0.70-0.92). The interrater and intrarater reliabilities were good (0.95 [0.87-0.98] and 0.94 [0.31-0.99], respectively). In all populations, a Bland-Altman analysis showed systematically higher scores using the multiple-choice Mini Mental State Examination. Administration of the multiple-choice Mini Mental State Examination to ICU patients was straightforward and produced exploitable results comparable to those of the standard Mini Mental State Examination. It should be of interest for the assessment and monitoring of the neurocognitive

  19. Summer Mini Atomiade June 2016

    CERN Multimedia

    Staff Association

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June. ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute. Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has now taken on the challenge of organising a Mini Atomiade from Friday June 3rd to Monday June 6th 2016 in Divonne-les-Bains. The games are made up of four different tournaments/competitions: Small Fi...

  20. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    Science.gov (United States)

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  1. Mini-open transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Tangviriyapaiboon, Teera

    2008-09-01

    To demonstrate the surgical technique and advantages of the mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation. Clinical and radiographic results were assessed to determine the clinical outcomes in twelve consecutive patients selected for minimally invasive access (mini-open technique) for TLIF in Prasat Neurological Institute. A retrospective analysis was performed on 12 patients (age range, 38-74 yr; mean, 54. 8 yr) who underwent mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation between September 2006 and June 2008. The titanium pedicle screws were introduced bilaterally through the 3.5 cm length, skin incisions with Spine Classics MLD- system retractor, autologous bone graft were inserted to perform TLIF in all patients. Eight patients were augmented anterior column support with titanium interbody cage, unilateral cage insertion in four patients and the others were inserted bilaterally interbody cages. Six patients presented with low back pain and associated radiculopathy, and six presented with low back pain only. Transforaminal lumbar interbody fusion was performed at L3-L4 in two patients, L4-L5 in four patients, L5-S1 in five patients, and two levels fusion in one patient. All patients were able to ambulate after spinal fusion. The patients were able to walk within 1.4 days (range 1-2 days). The hospital stay averaged 4.4 days (range 3-7 days). Periodic follow-up took place 1 to 21 months after surgery (mean, 7.4 months). The radiological fusion was archived in all nine patients who were operated on more than two months age. The other three patients who had been follow-up less than two months were probably fusion on the 1-month followed-up radiological examination. The use of mini-open technique for pedicle screw instrumentation with spinal fusion procedure provides excellent clinical results and may be an operation of choice for

  2. Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos

    Energy Technology Data Exchange (ETDEWEB)

    Faria, M.T.C. [Universidade Federal de Minas Gerais (DEMEC/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica], Email: mtcdf@uol.com.br; Martinez, C.B.; Viana, E.M.F. [Universidade Federal de Minas Gerais (EHR-UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Hidraulica e Recursos Hidricos], Emails: martinez@cce.ufmg.br, ednamariafaria@bol.com.br

    2009-07-01

    This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

  3. Methods for roof-top mini-arrays

    Science.gov (United States)

    Hazen, W. E.; Hazen, E. S.

    1985-08-01

    To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

  4. Styles of coping with cancer: the Italian version of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale.

    Science.gov (United States)

    Grassi, Luigi; Buda, Patrizia; Cavana, Laura; Annunziata, Maria Antonietta; Torta, Riccardo; Varetto, Antonella

    2005-02-01

    Mental adjustment to cancer has been explored in a large body of the literature by using the Mental Adjustment to Cancer (MAC) scale. Problems in the factor structure of the scale and the need for refining the instrument have determined the development of the Mini-MAC. The aim of this study was to validate, according to a test-oriented approach, the Italian version of the Mini-MAC. Four hundred and thirty cancer patients in five centres in Northern Italy completed the Mini-MAC and the Brief Symptom Inventory (BSI). A subgroup of 153 patients filled out the instruments again within 3 months of the first assessment. The five original subscales (Fighting Spirit, Hopeless, Fatalism, Anxious Preoccupation and Cognitive Avoidance) showed acceptable levels of reliability (Cronbach alpha coefficients ranging from 0.55 to 0.80) although alphas were lower for the scales Fighting Spirit and Fatalism. Factor analysis (Varimax rotation) identified the same five factors with minor variations from the original version. Again, alpha coefficients were less robust for the factors Fighting Sprit and Fatalism. Hopeless and Anxious Preoccupation were significantly related to all the BSI psychological stress symptoms, including the Global Stress Index (GSI). Test-retest reliability showed no differences in the sub-scales scores between assessments. Copyright (c) 2004 John Wiley & Sons, Ltd.

  5. Protective factor screening for prevention practice: Sensitivity and specificity of the DESSA-Mini.

    Science.gov (United States)

    Shapiro, Valerie B; Kim, B K Elizabeth; Robitaille, Jennifer L; LeBuffe, Paul A

    2017-12-01

    The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a district-wide implementation of a new social emotional learning (SEL) initiative designed to promote students' social-emotional competence. All students, kindergarten through Grade 8, were screened using the DESSA-Mini. A random 5 students per classroom received additional assessment. Concurrent and predictive criterion studies were conducted using the full DESSA as well as administrative records of serious disciplinary infraction. The DESSA-Mini showed excellent internal reliability, exceeding .90. Negligible to small differences were found between scores on the DESSA-Mini screen and the DESSA full assessment. Classification consistency between the DESSA-Mini and the DESSA was high (87%-94%) in routine practice, with sensitivity and specificity estimates exceeding Glascoe's (2005) standards. Finally, predictive validity of the DESSA-Mini was reliable; students screened as having a Need for SEL Instruction at the beginning of the year were 4.5 times more likely to have a record of serious disciplinary infraction at the end of the school year compared with those who were not identified (p mental, emotional, and behavioral problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  6. Mini-conference on Angular Momentum Transport in Laboratory and Nature

    International Nuclear Information System (INIS)

    Ji, Hantao; Kronberg, Philipp; Prager, Stewart C.; Uzdensky, Dmitri A.

    2008-01-01

    This paper provides a concise summary of the current status of the research and future perspectives discussed in the Mini-Conference on Angular Momentum Transport in Laboratory and Nature. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2007 Annual Meeting (November 12-16, 2007). This Mini-conference covers a wide range of phenomena happening in fluids and plasmas, either in laboratory or in nature. The purpose of this paper is not to comprehensively review these phenomena, but to provide a starting point for interested readers to refer to related research in areas other than their own

  7. Rational Design of Mini-Cas9 for Transcriptional Activation.

    Science.gov (United States)

    Ma, Dacheng; Peng, Shuguang; Huang, Weiren; Cai, Zhiming; Xie, Zhen

    2018-04-20

    Nuclease dead Cas9 (dCas9) has been widely used for modulating gene expression by fusing with different activation or repression domains. However, delivery of the CRISPR/Cas system fused with various effector domains in a single adeno-associated virus (AAV) remains challenging due to the payload limit. Here, we engineered a set of downsized variants of Cas9 including Staphylococcus aureus Cas9 (SaCas9) that retained DNA binding activity by deleting conserved functional domains. We demonstrated that fusing FokI nuclease domain to the N-terminal of the minimal SaCas9 (mini-SaCas9) or to the middle of the split mini-SaCas9 can trigger efficient DNA cleavage. In addition, we constructed a set of compact transactivation domains based on the tripartite VPR activation domain and self-assembled arrays of split SpyTag:SpyCatch peptides, which are suitable for fusing to the mini-SaCas9. Lastly, we produced a single AAV containing the mini-SaCas9 fused with a downsized transactivation domain along with an optimized gRNA expression cassette, which showed efficient transactivation activity. Our results highlighted a practical approach to generate down-sized CRISPR/Cas9 and gene activation systems for in vivo applications.

  8. Targeted CNS delivery using human MiniPromoters and demonstrated compatibility with adeno-associated viral vectors

    Directory of Open Access Journals (Sweden)

    Charles N de Leeuw

    2014-01-01

    Full Text Available Critical for human gene therapy is the availability of small promoters tools to drive gene expression in a highly specific and reproducible manner. We tackled this challenge by developing human DNA MiniPromoters (MiniPs using computational biology and phylogenetic conservation. MiniPs were tested in mouse as single-copy knock-ins at the Hprt locus on the X chromosome and evaluated for lacZ reporter expression in central nervous system (CNS and non–CNS tissue. Eighteen novel MiniPs driving expression in mouse brain were identified, 2 MiniPs for driving pan-neuronal expression and 17 MiniPs for the mouse eye. Key areas of therapeutic interest were represented in this set: the cerebral cortex, embryonic hypothalamus, spinal cord, bipolar and ganglion cells of the retina, and skeletal muscle. We also demonstrated that three retinal ganglion cell MiniPs exhibit similar cell type specificity when delivered via adeno-associated virus vectors intravitreally. We conclude that our methodology and characterization has resulted in desirable expression characteristics that are intrinsic to the MiniPromoter, not dictated by copy-number effects or genomic location, and results in constructs predisposed to success in adeno-associated virus. These MiniPs are immediately applicable for preclinical studies toward gene therapy in humans and are publicly available to facilitate basic and clinical research, and human gene therapy.

  9. Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?

    Science.gov (United States)

    Remadi, Jean-Paul; Marticho, Paul; Butoi, Irina; Rakotoarivelo, Zava; Trojette, Faouzi; Benamar, Amar; Beloucif, Sadek; Foure, Dominique; Poulain, Henri J

    2004-06-01

    We studied a cohort of 150 patients operated on with a new cardiopulmonary bypass (CPB) system. This is the mini-extracorporeal circulation (MECC) system. The MECC is a fully heparin coated closed-loop CPB system that includes a centrifugal pump and has a priming volume of 450 mL. Between March 2001 and September 2002, 150 consecutive patients were operated on using the mini-CPB (MECC) method. This includes 105 coronary artery bypass graft and 45 aortic valve replacement patients. The median age was 66.7 +/- 10.7 years with a gender ratio of 3.27 males to 1 female. The 30-day operative mortality was 1.3%. The hemoglobin concentration was stable and perioperative transfusion was needed in only 6% of all patients. The renal and neuropsychiatric complications were less than 1%. In our experience, the MECC system is a reliable new concept for CPB with good clinical results.

  10. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Directory of Open Access Journals (Sweden)

    LuisJoaquín Garcia-Lopez

    Full Text Available Social Anxiety Disorder (SAD is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain.The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1 and clinical sample (study 2.Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls. Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency.Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  11. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  12. Arc-to-arc mini-sling 1999: a critical analysis of concept and technology

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2011-04-01

    Full Text Available PURPOSE: The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique a less invasive mid-urethral sling using bovine pericardium as the sling material. MATERIALS AND METHODS: The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. RESULTS: The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. CONCLUSION: The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.

  13. Performance and internal flow condition of mini centrifugal pump with splitter blades

    International Nuclear Information System (INIS)

    Shigemitsu, T; Fukutomi, J; Kaji, K; Wada, T

    2012-01-01

    Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from the experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. The blade-to-blade low velocity regions are suppressed in the case with the splitter blades and the total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.

  14. Effect of recycling protocol on mechanical strength of used mini-implants.

    Science.gov (United States)

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.

  15. Magnet-Sleeve-Sealed Mini Trochoidal-Gear Pump Prototype with Polymer Composite Gear

    Directory of Open Access Journals (Sweden)

    Pedro Javier Gamez-Montero

    2017-09-01

    Full Text Available The trochoidal-gear technology has been growing in groundbreaking fields. Forthcoming applications are demanding to this technology a step forward in the conceiving stage of positive displacement machines. The compendium of the qualities and the inherent characteristics of trochoidal-gear technology, especially towards the gerotor pump, together with scale/size factor and magnetic-driven transmission has led to the idea of a magnet-sleeve-sealed variable flow mini trochoidal-gear pump. From its original concept, to the last phase of the design development, the proof of concept, this new product will intend to overcome problems such as noise, vibration, maintenance, materials, and dimensions. The paper aims to show the technological path followed from the concept, design, and model, to the manufacture of the first prototype, where the theoretical and numerical approaches are not always directly reflected in the prototype performance results. Early in the design process, from a standard-commercial sintered metal mini trochoidal-gear unit, fundamental characteristics and dimensional limitations have been evaluated becoming the strategic parameters that led to its configuration. The main technical challenge to confront is being sealed with non-exterior driveshaft, ensuring that the whole interior is filled and wetted with working fluid and helping the hydrodynamic film formation, the pumping effect, and the heat dissipation. Subsequently, the mini pump architecture, embodiment, methodology, materials, and manufacture are presented. The trend of applications of polymer composite materials and their benefits wanted to be examined with this new mini pump prototype, and a pure polyoxymethylene mini trochoidal-gear set has been designed and manufactured. Finally, both the sintered and the polymer trochoidal-gear units have been experimentally tested in an in-house full-instrumented mini test bench. Although the main goal of the presented work is the

  16. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  17. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  18. "Mini", "Midi" and the Student.

    Science.gov (United States)

    Edwards, Perry; Broadwell, Bruce

    Mini- and midi-computers have been introduced into the computer science program at Sierra College to afford students more direct contact with computers. The college's administration combined with the Science and Business departments to share the expense and utilization of the program. The National Cash Register Century 100 and the Data General…

  19. Mini International Neuropsychiatric Interview (MINI): validação de entrevista breve para diagnóstico de transtornos mentais

    OpenAIRE

    Amorim, Patrícia

    2000-01-01

    Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos), compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas). A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudo...

  20. Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study.

    Science.gov (United States)

    Catalán, Alfonso; Martínez, Alejandra; Marchesani, Francisco; González, Urcesino

    2016-07-01

    Patients with atrophic edentulous ridges generally have problems with retention, therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to assist in improving retention and stability involves the use of mini-implants. The aim of this study was to evaluate the retention of mandibular overdentures connected to two mini-implants and overall patient satisfaction with them. Seven patients with atrophic mandibular ridges (Type 4D Misch classification), aged 62 to 74 years old were rehabilitated with complete dentures. In each patient, two mini-implants measuring 15 or 13 mm in length and 1.8 mm in diameter were placed. After 15 days, overdentures were connected to the mini-implants with O-ring attachments. In each patient, retention of the overdentures was measured, and a survey of therapeutic satisfaction before and after connection to the mini-implants was administered. Prosthesis retention was measured with a digital dynamometer at 1 month, 6 months, and 2, 3, 5, and 7 years after mini-implant placement. Patient satisfaction was assessed with a survey. Data were analyzed with Student's t-test (satisfaction survey) and the Friedman test (retention measurements and satisfaction survey). The initial retention values (0.34 to 0.63 N without mini-implants) varied significantly (p ≤ 0.050). These values were less than the subsequent measurements of 3.92 to 9.64 N, taken after placement of the mini-implants and connecting them to the dentures. Satisfaction was good to very good over the 7-year observation period. Mucosa and peri-implant bone showed no pathological changes. In this limited sample size clinical study the results indicated that after connecting mandibular overdentures to two mini-implants, patient satisfaction significantly increased and retention significantly improved during the 7-year observation period. © 2015 by the American College of Prosthodontists.

  1. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  2. Eficacia del proceso de esterilización de los Mini-Endo-bloc

    Directory of Open Access Journals (Sweden)

    Maritza Eraso Rodríguez

    2017-01-01

    Full Text Available El Mini-Endo-Bloc® es un elemento usado para mediar las limas durante la endodoncia, presenta muchas concavidades y orificios que dificultan el proceso de esterilización y pueden promover la infección cruzada o comprometer el pronóstico del tratamiento endodóntico. Objetivo: Observar la eficacia de la esterilización de los Mini-Endo-Bloc® utilizados en la clínica de la Federación Odontológica Colombiana (FOC. Métodos: Se recolectaron 60 Mini-Endo-Bloc® utilizados en pacientes que presentaban diagnósticos de necrosis pulpar y periodontitis apical, lo cuales se dividieron en dos grupos: Grupo control: 12 Mini-Endo-Bloc® desinfectados y no esterilizados. Grupo experimental: 48 Mini-Endo-Bloc® desinfectados y esterilizados, se realizó, según lo recomendado por la Farmacopea USPXXXV, prueba de esterilidad en Caldo Thioglycollate a 37°C, medio de caldo Casoy a 37°C y medio de caldo Casoy a 25°C para determinar presencia de bacterias, levaduras y hongos. Resultados: Al someter los Mini-Endo-Bloc® al protocolo de esterilización establecido por la FOC y teniendo en cuenta los parámetros de las pruebas de esterilidad, en el grupo experimental el 50% (n=24, fueron reprobadas (crecimiento microorganismos y 50% (n = 24 fueron aprobadas (no crecimiento de microorganismos. Discusión: la mitad de las muestras fueron reprobadas, estos resultados pueden ser por fallas en el proceso de desinfección mecánica manual directa, el cual se dificulta en los Mini-Endo-Bloc®, debido a su estructura y diseño, permitiendo que residuos biológicos permanezcan en la superficie del instrumento, evitando que el vapor saturado entre en contacto con el material o los microorganismos durante la esterilización.

  3. How does feedback in mini-CEX affect students' learning response?

    Science.gov (United States)

    Sudarso, Sulistiawati; Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-12-19

    This study was aimed to explore students' learning response toward feedback during mini-CEX encounter. This study used a phenomenological approach to identify the students' experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Feedback content and the way of providing feedback on mini-CEX stimulated students' internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students' reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students' increased self-efficacy, attitude, knowledge and clinical skill. Feedback content and the way of providing feedback on mini-CEX stimulates the students' internal processes to do a follow-up on feedback. However, another external factor also affects the students' decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students' learning response.

  4. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T. A.

    2015-01-01

    Objectives Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. Methods The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Results Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Conclusions Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided. PMID:26317695

  5. Mini-implants: alternative for oral rehabilitation of a child with ectodermal dysplasia.

    Science.gov (United States)

    Mello, Bianca Zeponi Fernandes; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Valarelli, Fabrício Pinelli; Oliveira, Thais Marchini

    2015-01-01

    Ectodermal dysplasia is a rare congenital disease that affects several structures of ectodermal origin. The most commonly related oral characteristics are hypodontia, malformed teeth and underdeveloped alveolar ridges. New alternative treatments are needed due to the failure of the conventional prosthesis retention. This case report outlines the oral rehabilitation treatment of a 9-year-old girl with ectodermal dysplasia. The treatment was performed with conventional prosthesis upon mini-implants. The mini-implants provided prosthetic retention. The patient reported a good adaptation of the dental prosthesis and satisfaction with the treatment. The increased self-esteem improved the socialization skills of the girl. In this case report, use of prosthesis with mini-implants was satisfactory for prosthetic retention. However, clinical studies with long-term follow-up are needed to test the mini-implants as an alternative for oral rehabilitation of children with ectodermal dysplasia.

  6. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    2002-06-01

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  7. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.

    Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  8. Investigation of Heat Transfer in Mini Channels using Planar Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Bøgild, Morten Ryge; Poulsen, Jonas Lundsted; Rath, Emil Zacho

    2012-01-01

    In this paper an experimental investigation of the heat transfer in mini channels with a hydraulic diameter of 889 m is conducted. The method used is planar laser induceduorescence (PLIF), which uses the principle of laser excitation of rhodamine B in water. The goal of this study is to validate...... the applicability of PLIF to determine the convective heat transfer coecient in mini channels against conventional correlations of the convective heat transfer coecient. The applicability of the conventional theory in micro and mini channels has been discussed by several researchers, but to the authors knowledge...

  9. Mini-tablets versus pellets as promising multiparticulate modified release delivery systems for highly soluble drugs.

    Science.gov (United States)

    Gaber, Dina M; Nafee, Noha; Abdallah, Osama Y

    2015-07-05

    Whether mini-tablets (tablets, diameters ≤6mm) belong to single- or multiple-unit dosage forms is still questionable. Accordingly, Pharmacopoeial evaluation procedures for mini-tablets are lacking. In this study, the aforementioned points were discussed. Moreover, their potential for oral controlled delivery was assessed. The antidepressant venlafaxine hydrochloride (Vx), a highly soluble drug undergoing first pass effect, low bioavailability and short half-life was selected as a challenging payload. In an attempt to weigh up mini-tablets versus pellets as multiparticulate carriers, Vx-loaded mini-tablets were compared to formulated pellets of the same composition and the innovator Effexor(®)XR pellets. Formulations were prepared using various polymer hydrogels in the core and ethyl cellulose film coating with increasing thickness. Mini-tablets (diameter 2mm) showed extended Vx release (<60%, 8h). Indeed, release profiles comparable to Effexor(®)XR pellets were obtained. Remarkably higher coating thickness was required for pellets to provide equivalent retardation. Ethyl cellulose in the core ensured faster release due to polymer migration to the surface and pore formation in the coat. mini-tablets showed higher stability to pellets upon storage. Industrially speaking, mini-tablets proved to be superior to pellets in terms of manufacturing, product quality and economical aspects. Results point out the urgent need for standardized evaluation procedures for mini-tablets. Copyright © 2015. Published by Elsevier B.V.

  10. Psychometric Properties of the Persian Adaptation of Mini-Cog Test in Iranian Older Adults.

    Science.gov (United States)

    Rezaei, Mohammad; Rashedi, Vahid; Lotfi, Gohar; Shirinbayan, Peymaneh; Foroughan, Mahshid

    2018-04-01

    The aim of this study was to assess the psychometric properties of the Mini-Cog in Iranian older adults. It was a cross-sectional study; 50 older people with dementia and 50 without dementia who matched for age, gender, and education entered the study. The diagnostic and statistical manual of mental disorders criteria for dementia were used as gold standard. A battery of scales included the abbreviated mental test score (AMTS), the Geriatric Depression Scale, and the Mini-Cog was performed. Validity and reliability of the Mini-Cog determined using the Pearson product-moment correlation coefficient (Pearson's r), Cronbach's alpha, and Receiver Operating Characteristic (ROC) curve analysis. The Persian version of Mini-Cog showed a good inter-rater reliability ( K = 0.76, p Mini-Cog have an acceptable sensitivity, specificity, and substantial overall agreement with the AMTS.

  11. The MiniBIOS model (version 1A4) at the RIVM

    NARCIS (Netherlands)

    Uijt de Haag PAM; Laheij GMH

    1993-01-01

    This report is the user's guide of the MiniBIOS model, version 1A4. The model is operational at the Laboratory of Radiation Research of the RIVM. MiniBIOS is a simulation model for calculating the transport of radionuclides in the biosphere and the consequential radiation dose to humans. The

  12. Role of mini-scleral lens in mucous membrane pemphigoid

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2017-01-01

    Full Text Available This study aims to report the use of mini-scleral contact lens in the management of mucous membrane pemphigoid (MMP with persistent epithelial defects. A 68-year-old male with a history of ocular pain and declining visual acuity was referred to our clinic with a diagnosis of MMP. His corrected distance visual acuity (CDVA was 20/200 in the right eye and 20/100 in the left eye. Despite being on lubricants, topical steroids and intravenous cyclophosphamide, the patient developed persistent corneal epithelial defects in both eyes. He was then given a trial of mini-scleral lenses. Within 4 weeks, corneal epithelial defects healed, and at 6 months, the CDVA had improved to 20/50 in the right eye and 20/40 in the left eye. By improving the corneal surface integrity and visual function, mini-scleral lenses can play a role in the visual rehabilitation of patients with MMP.

  13. Caracterização de mini-implantes utilizados na ancoragem ortodôntica Characterization of the mini-implants used to orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Luciana Rougemont Squeff

    2008-10-01

    Full Text Available INTRODUÇÃO: o diâmetro reduzido do mini-implante, e a decorrente facilidade na sua inserção, minimizam a possibilidade de erro do operador e de contato entre a rosca do mini-implante e a raiz dentária. Entretanto, o risco de fratura da peça aumenta à medida que seu diâmetro é diminuído. MÉTODOS: neste trabalho foram analisados quatro produtos de marcas nacionais (INP, SIN, Conexão e Neodente e um de marca alemã (Mondeal, com o objetivo de identificar características importantes para o bom desempenho deste recurso como acessório de ancoragem. Foram observados composição e design das peças e realizado o ensaio mecânico de torque até a fratura (estudo in vitro, cujos valores foram submetidos à análise de variância (ANOVA e teste de Tukey. RESULTADOS: os resultados mostraram que todos os mini-implantes testados estão aptos à utilização clínica como reforço de ancoragem ortodôntica.INTRODUCTION: The reduced diameter of the mini-implants and the simplicity of the technique could minimize the operator mistake's possibility and avoid the contact between the thread of the screw and the dental root. In spite of that, it increases the fracture risk because of the diameter's decrease. METHODS: At the present work, mini-implants from five different trade marks, four Brazilian systems (INP, SIN, Conexão and Neodente and a German system (Mondeal were studied to identify important characteristics of this anchorage accessory, like composition, design and resistance to the insertion torque (in vitro. The values obtained from the mechanical torque test were submitted to variance analysis (ANOVA and Tukey's test. RESULTS: All studied groups presented good results and are recommended to orthodontic clinic use.

  14. Chinese Journalism Education: Slow Progress since 1918.

    Science.gov (United States)

    Jingming, Zhang; Jiana, Peng

    1986-01-01

    Notes that journalism education prior to 1949 was modeled after American journalism schools, while since the 1950s, that orientation has been replaced by Soviet principles. Observes the projected shortage of journalism graduates and the need for increased capacity in journalism institutions and for increased international exchange. (HTH)

  15. Post irradiation examination of HANARO nucler mini-element fuel (metallographic and density test)

    International Nuclear Information System (INIS)

    Yoo, Byung Ok; Hong, K. P.; Park, D. G.; Choo, Y. S.; Baik, S. J.; Kim, K. H.; Kim, H. C.; Jung, Y. H.

    2001-05-01

    The post irradiation examination of a HANARO mini-element nuclear fuel, KH96C-004, was done in June 6, 2000. The purpose of this project is to evaluate the in-core performance and reliability of mini-element nuclear fuel for HANARO developed by the project T he Nuclear Fuel Material Development of Research Reactor . And, in order to examine the performance of mini-element nuclear fuel in normal output condition, the post irradiation examination of a nuclear fuel bundle composed by 6 mini nuclear fuel rods and 12 dummy fuel rods was performed. Based on these examination results, the safety and reliability of HANARO fuel and the basic data on the design of HANARO nuclear fuel can be ensured and obtained,

  16. Primary fixation of mini slings: a comparative biomechanical study in vivo

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2012-04-01

    Full Text Available INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control, as follows: TVT-Secur® (Gynecare, USA, Type 1 polypropylene mesh (control; Ophira Mini Sling System® (Promedon, Argentina, Tissue Fixation System® (TFS PTY, Australia, Zipper Sling® and "T device" (Prosurg, USA. The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments. The force was measured in Newtons (N. RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.

  17. Validity of a short clinical interview for psychiatric diagnosis : the mini-SCAN

    NARCIS (Netherlands)

    Nienhuis, F. J.; van de Willige, G.; Rijnders, C. A. Th.; de Jonge, P.; Wiersma, D.

    Background To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. Aims To establish the validity and practical properties of the mini-SCAN. Method One hundred

  18. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  19. Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis.

    Science.gov (United States)

    You, Tao; Yi, Kang; Ding, Zhao-Hong; Hou, Xiao-Dong; Liu, Xing-Guang; Wang, Xin-Kuan; Ge, Long; Tian, Jin-Hui

    2017-06-21

    Both transcatheter device closure and surgical repair are effective treatments with excellent midterm outcomes for perimembranous ventricular septal defects (pmVSDs) in children. The mini-invasive periventricular device occlusion technique has become prevalent in research and application, but evidence is limited for the assessment of transcatheter closure, mini-invasive closure and open-heart surgical repair. This study comprehensively compares the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of pmVSDs in children using Bayesian network meta-analysis. A systematic search will be performed using Chinese Biomedical Literature Database, China National Knowledge Infrastructure, PubMed, EMBASE.com and the Cochrane Central Register of Controlled Trials to include random controlled trials, prospective or retrospective cohort studies comparing the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair. The risk of bias for the included prospective or retrospective cohort studies will be evaluated according to the risk of bias in non-randomised studies of interventions (ROBINS-I). For random controlled trials, we will use risk of bias tool from Cochrane Handbook version 5.1.0. A Bayesian network meta-analysis will be conducted using R-3.3.2 software. Ethical approval and patient consent are not required since this study is a network meta-analysis based on published trials. The results of this network meta-analysis will be submitted to a peer-reviewed journal for publication. CRD42016053352. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Preparation and Evaluation of Hot-Melt Extruded Patient-Centric Ketoprofen Mini-Tablets.

    Science.gov (United States)

    Alshetaili, Abdullah S; Almutairy, Bjad K; Tiwari, Roshan V; Morott, Joseph T; Alshehri, Sultan M; Feng, Xin; Alsulays, Bader B; Park, Jun-Bom; Zhang, Feng; Repka, Michael A

    2016-01-01

    Bitter tasting drugs represent a large portion of active pharmaceutical ingredients. Mini-tablets are specifically designed for patients with difficulty in swallowing particular in young children up to 10 years of age, geriatric patients and patients with esophagitis. The present study was aimed to prepare, taste-masked mini-tablets, which are easily swallowed dosage forms, primarily to be used by pediatric and geriatric patients. Ketoprofen (10%-50% w/w) and Eudragit® EPO were blended and extruded with a 5-mm strand die and cut into consistent mini-tablets by using an adapted downstream pelletizer. Differential scanning calorimetry and polarized light microscopy-hot stage microscopy studies confirmed that the binary mixtures were miscible under the employed extrusion temperatures. In-vitro release studies showed that drug release was less than 0.5% within the first 2 min in simulated salivary fluid (pH 6.8) and more than 90% in the first 20 min in gastric media (pH 1.0). The results of the electronic tongue analysis were well correlated with the drug release profile of the mini-tablets in the artificial saliva. Scanning electron microscopy revealed no cracks on the surface of the minitablets, confirming that the mini-tablets were compact solids. Chemical imaging confirmed the uniform distribution of ketoprofen inside the polymer matrices. Eudragit® EPO containing ketoprofen at various drug loads were successfully melt extruded into tastedmasked mini-tablets. The reduced drug release at salivary pH correlated well with Astree e-Tongue studies for taste masking efficiency.

  1. Identification of processed Chinese medicinal materials using DNA mini-barcoding.

    Science.gov (United States)

    Song, Ming; Dong, Gang-Qiang; Zhang, Ya-Qin; Liu, Xia; Sun, Wei

    2017-07-01

    Most of Chinese medicinal herbs are subjected to traditional processing procedures, including stir-frying, charring, steaming, boiling, and calcining before they are released into dispensaries. The marketing and identification of processed medicinal materials is a growing issue in the marketplace. However, conventional methods of identification have limitations, while DNA mini-barcoding, based on the sequencing of a short-standardized region, has received considerable attention as a new potential means to identify processed medicinal materials. In the present study, six DNA barcode loci including ITS2, psbA-trnH, rbcL, matK, trnL (UAA) intron and its P6 loop, were employed for the authentication of 45 processed samples belonging to 15 species. We evaluated the amplification efficiency of each locus. We also examined the identification accuracy of the potential mini-barcode locus, of trnL (UAA) intron P6 loop. Our results showed that the five primary barcode loci were successfully amplified in only 8.89%-20% of the processed samples, while the amplification rates of the trnL (UAA) intron P6 loop were higher, at 75.56% successful amplification. We compared the mini-barcode sequences with Genbank using the Blast program. The analysis showed that 45.23% samples could be identified to genus level, while only one sample could be identified to the species level. We conclude that trnL (UAA) p6 loop is a candidate mini-barcode that has shown its potential and may become a universal mini-barcode as complementary barcode for authenticity testing and will play an important role in medicinal materials control. Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  2. How does feedback in mini-CEX affect students’ learning response?

    Science.gov (United States)

    Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-01-01

    Objective This study was aimed to explore students’ learning response toward feedback during mini-CEX encounter. Methods This study used a phenomenological approach to identify the students’ experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Results Feedback content and the way of providing feedback on mini-CEX stimulated students’ internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students’ reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students’ increased self-efficacy, attitude, knowledge and clinical skill. Conclusions Feedback content and the way of providing feedback on mini-CEX stimulates the students’ internal processes to do a follow-up on feedback. However, another external factor also affects the students’ decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students’ learning response. PMID:28008136

  3. Grau de aceitação de mini-implantes por pacientes em tratamento ortodôntico: estudo preliminar The mini-implants acceptance rate by patients in orthodontic treatments: a preliminary study

    Directory of Open Access Journals (Sweden)

    Larissa Bustamante Capucho Brandão

    2008-10-01

    Full Text Available OBJETIVOS: os mini-implantes atualmente representam um grande avanço na Ortodontia, por proporcionarem máxima ancoragem com o mínimo de cooperação dos pacientes. No entanto, ainda existem algumas dúvidas quanto ao uso destes dispositivos temporários de ancoragem no que se refere, principalmente, aos aspectos psicológicos de aceitação pelos pacientes durante o tratamento ortodôntico. METODOLOGIA: dez pacientes adultos, portadores de má oclusão de Classe I, com biprotrusão, que foram submetidos a tratamento ortodôntico com a colocação de quatro mini-implantes nos arcos dentários, entre os primeiros molares e segundos pré-molares superiores e inferiores, responderam a um questionário, com o objetivo de avaliar as condições de aceitação dos mini-implantes. RESULTADOS: as respostas indicaram que a maioria dos pacientes aceitou prontamente o procedimento, estavam satisfeitos e recomendariam para outros pacientes (90%, enquanto 50% tiveram alguma preocupação com os procedimentos cirúrgicos e os outros 50% não relataram nenhum desconforto. O tempo médio de tolerância a partir da colocação foi de 3 dias e a maioria tolerou os implantes durante todo o tratamento ortodôntico. CONCLUSÕES: pôde-se concluir que os mini-implantes foram aceitos de forma positiva pela maioria dos pacientes submetidos ao tratamento ortodôntico.OBJECTIVE: Actually, mini-implants as anchorage resources have been spotlight in Orthodontics, providing maximum anchorage with minimum patient's cooperation. However, there are still some restrictions regarding the use of these temporary anchorage devices, and among these, the psychological aspects and the patient's acceptance, which still not properly evaluated. METHODS: Ten adults patients, with Class I biprotrusion malocclusion, that were submitted to orthodontic treatment with the implantation of four mini-implants, in the dental arches, among upper and lower first molar and second premolar teeth, in

  4. The Norwegian version of the Mini-Mental Adjustment to Cancer Scale: factor structure and psychometric properties.

    Science.gov (United States)

    Bredal, Inger Schou

    2010-02-01

    The object of the study was to examine the factor structure and the psychometric properties of the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) among a large sample of Norwegian breast cancer patients. A total of 402 patients with breast cancer completed the Mini-MAC. Principal component analysis with varimax rotion confirmed four factors. Three had psychometric properties to the original Mini-MAC Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) subscales. The fourth, named Positive Attitude (PA) combined the Fighting Spirit (FS) and the Fatalism subscales of the original Mini-MAC. Construct validities were assessed by examining the interscale correlations as well as the correlations between the Mini-MAC subscales and the HADS subscales scores. Internal consistency of the five subscales was satisfactory for the original (HH, AP, CA, FA, coefficients=0.60-0.83), except for the FS subscale (coefficient=21). In view of the low internal reliability for the Norwegian Mini-MAC FS subscale coefficient; it appears to be more appropriate to use the Norwegian Mini-MAC as a four-factor model. If researcher or clinicians in Norway use the five-factor model, they should take great care when interpreting the fighting spirit subscale.

  5. From Rindler horizon to mini black holes at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Ghaffary, Tooraj [Islamic Azad University, Department of Science, Shiraz Branch, Shiraz (Iran, Islamic Republic of)

    2017-02-15

    Recently researchers (A. Sepehri et al., Astrophys. Space Sci. 344, 79 (2013)) have considered the signature of superstring balls near mini black holes at LHC and calculate the information loss for these types of strings. Motivated by their work, we consider the evolution of events in high energy experiments from lower energies for which the Rindler horizon is formed to higher energies in which mini black holes and string balls are emerged. Extending the Gottesman and Preskill method to string theory, we find the information loss for excited strings ''string balls'' in mini black holes at LHC and calculate the information transformation from the collapsing matter to the state of outgoing Hawking radiation for strings. We come to the conclusion that information transformation for high energy strings is complete. Then the thermal distribution of excited strings near mini black holes at LHC is calculated. In order to obtain the total string cross section near black holes produced in proton-proton collision, we multiply the black hole production cross section by the thermal distribution of strings. It is observed that many high energy excited strings are produced near the event horizon of TeV black holes. These excited strings evaporate to standard model particles like Higgs boson and top quark at Hagedorn temperature. We derive the production cross section for these particles due to string ball decay at LHC and consider their decay to light particles like bottom quarks and gluons. (orig.)

  6. Model Pemberdayaan Laboratorium Bank Mini Syariah di Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Eva Fauziah

    2018-03-01

    results showed that the model of empowerment of Mini Sharia Bank laboratory in Higher Education has four models; they are 1 model of secondary empowerment, 2 model primary internal empowerment of student, 3 model of primary internal empowerment of student and lecturer and 4 model of primary external empowerment. This laboratory empowerment model is based on observations at four universities in Java, namely Bandung Islamic University (UNISBA, Islamic University of Malang (UNISMA, UIN Malang and UIN Sunan Ampel Surabaya. Laboratorium Bank Mini Syariah merupakan sarana penunjang dan pelaksana program Tri Dharma Perguruan Tinggi yang diharapkan mampu memberikan kontribusi untuk mengakselerasi perkembangan syariah di Indonesia. Oleh karena itu, pemberdayaan laboratorium Bank Mini Syariah sebagai tempat mengembangkan kompetensi baik dalam bidang intelektual, ketrampilan motorik dan terampil memggunakan alat-alat media perbankan syariah untuk peningkatan kompetensi mahasiswa lulusan keuangan dan perbankan syariah perlu ditelaah. Metode penelitian menggunakan metode kualitatif dengan teknik pengumpulan data observasi mendalam. Analisis data menggunakan analisis domain model spradley. Hasil penelitian menunjukkan bahwa model pemberdayaan laboratorium Bank Mini Syariah di Perguruan Tinggi memiliki empat model yaitu 1. Model pemberdayaan sekunder, 2. Model pemberdayaan primer internal mahasiswa, 3. Model pemberdayaan primer internal mahasiswa dan dosen, dan 4. Model pemberdayaan primer eksternal. Model pemberdayaan laboratorium ini berdasarkan pengamatan pada empat perguruan tinggi di Jawa yaitu Universitas Islam Bandung, Universitas Islam Malang, UIN Malang dan UIN Sunan Ampel Surabaya.

  7. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    International Nuclear Information System (INIS)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda

    2016-01-01

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  8. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda [University of Saskatchewan Department of Physics and engineering Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics (Canada)

    2016-08-15

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  9. Neutronics analysis on mini test fuel in the RSG-GAS core

    International Nuclear Information System (INIS)

    Tukiran S; Tagor M Sembiring

    2016-01-01

    Research on UMo fuel for research reactor has been developed. The fuel of research reactor is uranium molybdenum low enrichment with high density. For supporting the development of fuel fabrication, an neutronic analysis of mini fuel plates in the RSG-GAS core was performed. The aim of analysis is to determine the numbers of fuel cycles in the core to know the maximum fuel burn-up. The mini fuel plates of U_7Mo-Al and U_6Zr-Al with densities of 7.0 gU/cc and 5.2 gU/cc, respectively, will be irradiated in the RSG-GAS core. The size of both fuels, namely 630 x 70.75 x 1.30 mm were inserted to the 3 plates of dummy fuel. Before the fuel will be irradiated in the core, a calculation for safety analysis from neutronics and thermal-hydraulics aspects were required. However, in this paper, it will be discussed safety analysis of the U_7Mo-Al and U_6Zr-Al mini fuels from neutronic point of view. The calculation was done using WIMSD-5B and Batan-3DIFF codes. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. If it is compared, the power density of U_7Mo-Al mini fuel is bigger than U_6Zr-Al fuel. (author)

  10. Final report of phase 2 'Mini-cogeneration in the flower bulb industry'; Eindrapportage Fase 2 'Mini-WKK in de bloembollensector'

    Energy Technology Data Exchange (ETDEWEB)

    Koolwijk, E. [Cogen Projects, Driebergen-Rijsenburg (Netherlands); Smailbegovic, N. [SenterNovem, Utrecht (Netherlands)

    2009-09-15

    Phase 2 of the project 'mini-cogeneration in the flower bulb industry' is the sequel to the report 'mini-cogeneration in the flower bulb industry. Use of cogeneration in the cultivation and hot bed of tulip and hyacinth', Addressing the incentivisation of the use of cogeneration in the sector and working toward realizing a number of demonstration projects. To this end it is necessary that potential investors are given insight in the feasibility of cogeneration at their business and that their enthusiasm is kindled for the use of cogeneration. This was done by disseminating information in the flower bulb industry about the opportunities of cogeneration and by informing growers about technique, economy and points of interest. [Dutch] Fase 2 van het project 'Mini- WKK in de bloembollensector' is een vervolg op het rapport 'Mini-wkk in de bloembollensector. Toepassing van wkk bij teelt en broei van tulp en hyacint' en richt zich op het stimuleren van de toepassing van WKK in de sector en toewerken naar realisatie van een aantal demonstratieprojecten. Daartoe is het noodzakelijk dat potentiele investeerders inzicht krijgen over de haalbaarheid van WKK op hun bedrijf en geenthousiasmeerd worden voor het gebruik van WKK. Dit is gedaan door informatie in de bollensector te verspreiden over de mogelijkheden van WKK en telers te informeren over techniek, economie en aandachtspunten.

  11. Summer Mini Atomiade in June 2016

    CERN Multimedia

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June.   ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute.  Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has taken on the challenge of organising a Mini Atomiade from Friday 3 June to Monday 6 June 2016 in Divonne-les-Bains. The ga...

  12. Four-stranded mini microtubules formed by Prosthecobacter BtubAB show dynamic instability.

    Science.gov (United States)

    Deng, Xian; Fink, Gero; Bharat, Tanmay A M; He, Shaoda; Kureisaite-Ciziene, Danguole; Löwe, Jan

    2017-07-18

    Microtubules, the dynamic, yet stiff hollow tubes built from αβ-tubulin protein heterodimers, are thought to be present only in eukaryotic cells. Here, we report a 3.6-Å helical reconstruction electron cryomicroscopy structure of four-stranded mini microtubules formed by bacterial tubulin-like Prosthecobacter dejongeii BtubAB proteins. Despite their much smaller diameter, mini microtubules share many key structural features with eukaryotic microtubules, such as an M-loop, alternating subunits, and a seam that breaks overall helical symmetry. Using in vitro total internal reflection fluorescence microscopy, we show that bacterial mini microtubules treadmill and display dynamic instability, another hallmark of eukaryotic microtubules. The third protein in the btub gene cluster, BtubC, previously known as "bacterial kinesin light chain," binds along protofilaments every 8 nm, inhibits BtubAB mini microtubule catastrophe, and increases rescue. Our work reveals that some bacteria contain regulated and dynamic cytomotive microtubule systems that were once thought to be only useful in much larger and sophisticated eukaryotic cells.

  13. Neutrinos from the NuMI beamline in the MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, Alexis A.

    2006-01-01

    With the startup of the NuMI beamline early in 2005, the MiniBooNE detector has the unique opportunity to be the first user of an off-axis neutrino beam (110 mrad off-axis). MiniBooNE is assembling a rich sample of neutrino interactions from this source

  14. USE OF RENEWABLE SUBSTRATES FOR EX VITRO PRODUCTION OF Melaleuca alternifolia CHEEL CLONAL PLANTS BY MINI-CUTTINGS TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Carlos Andre Stuepp

    2017-12-01

    Full Text Available The Australian species Melaleuca alternifolia Cheel. has a strong commercial importance due to the extraction of essential oils from its leaves used in the cosmetic and pharmaceutical industry. In order to obtain an efficient plant production system of M. alternifolia the mini-cuttings technique and the clonal mini-garden management in the productivity and rooting of mini-cuttings and different substrate compositions were analyzed during all the seasons. Mini-stumps derived from cuttings and grown in pots (2 L, were submitted to successive harvesting of their sprouts during the four seasons (september/2013 to august/2014. From the mini-stumps sprouts mini-cuttings were produced, wich were were planted in plastic tubes and kept in a greenhouse for 45 days. Six substrates were used for planting the mini-cuttings: commercial substrate (S1; substrate composed of 100% carbonized rice husk (CRH (S2; substrate composed of 100% coconut fiber (CF (S3; substrate composed of 50% CF and 50% CRH (S4; substrate composed of 30% CF and 70% CRH (S5; substrate composed of 70% FC and 30% CRH (S6. The high survival of mini-stumps (over 90% and the mini-cuttings production (282 mini-cuttings.m-2.month-1 in the shade house demonstrate the technical feasibility for the species, being summer the most appropriate time to collect propagules. The substrate composed by 70% CF + 30% CRH (S6 shows superior results for vegetative propagation of M. alternifolia (91.7% of rooted mini-cuttings, as the single one to contemplate simultaneously all parameters. Summer is recommended as the best time for rooting of mini-cuttings.

  15. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  16. Mini-interfacial Fracture Toughness of a Multimode Adhesive Bonded to Plasma-treated Dentin.

    Science.gov (United States)

    Ayres, Ana Paula Almeida; Pongprueksa, Pong; De Munck, Jan; Gré, Cristina Parise; Nascimento, Fábio Dupart; Giannini, Marcelo; Van Meerbeek, Bart

    2017-01-01

    To investigate the bonding efficacy of a multimode adhesive to plasma-treated and -untreated (control) dentin using a mini-interfacial fracture toughness (mini-iFT) test. Twenty human molars were used in a split-tooth design (n = 10). The adhesive Scotchbond Universal (SBU; 3M ESPE) was applied in etch-and-rinse (E&R) and self-etch (SE) modes. Mid-coronal dentin was exposed and covered with a standardized smear layer ground to 320 grit. One half of each dentin surface received 15 s of non-thermal atmospheric plasma (NTAP), while the other half was covered with a metallic barrier and kept untreated. Following the E&R mode, dentin was plasma treated immediately after phosphoric acid etching. SBU and a resin-based composite were applied to dentin following the manufacturer's instructions. Six mini-iFT specimens were prepared per tooth (1.5 x 2.0 x 16 to 18 mm), and a single notch was prepared at the adhesive-dentin interface using a 150-μm diamond blade under water cooling. Half of the mini-iFT specimens were immediately loaded until failure in a 4-point bending test, while the other half were first stored in distilled water for 6 months. After testing, the exact dimensions of the notch were measured with a measuring optical microscope, from which ΚIc was determined. Three-way ANOVA revealed higher mini-iFT for SBU applied in E&R than SE mode for both storage times, irrespective of NTAP treatment. Overall, mini-iFT did not decrease for any of the experimental groups upon 6-month aging, while plasma treatment did not show a direct beneficial effect on mini-iFT of SBU applied in either E&R or SE mode.

  17. Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.

    Science.gov (United States)

    Gurdan, Z; Szalma, J

    2018-05-01

    Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.

  18. Development of a multiparticulate system containing enteric-release mini-tablets of omeprazole

    Directory of Open Access Journals (Sweden)

    Volnei Jose Tondo Filho

    2014-09-01

    Full Text Available The main aim of this study was to develop a multiparticulate system containing mini-tablets of omeprazole formulated with an enteric polymer with pH-dependent solubility. Pre-formulation studies showed good flow and compaction capacity, leading to the production ofhigh quality mini-tablets. The mini-tablets were coated in a fluidized bed with hydroxypropylmethylcellulose /Eudragit(r L30D55 and packed into hard gelatin capsules. The dissolution profile showed gastro-resistance and zero-order kinetics. The dissolution profile for the formulation containing lactose as the diluent and coated with 12% (tablet weight gain of polymer was similar to that ofthe reference drug.

  19. Mini hydro power in Peninsular Malaysia - the past, present and future

    International Nuclear Information System (INIS)

    Bhaskar Kannan

    2006-01-01

    The early development of mini hydro development in Peninsular Malaysia was carried out by the National Electricity Board (NEB) and the projects developed in the 50s and 60s were Ulu Langat (Selangor), Sempam, Kg. Raja , Kuala Terla, and Robinson Falls (all in Pahang). In the 70s the main effort of hydropower development was concentrated on developing major hydropower projects not only to cater to the country increasing demand for electricity but also to the country needs for flood control. This development was feverishly carried out on the Perak River and the prohects built were Temenggor (384 MW), Bersia (72 MW), Kenering (20 MW), Sg Piah (70 MW) and the Kenyir (400 MW) project in Sungai Terengganu. In late 1970s, the government was keen to electrify the rural areas of Peninsular Malaysia and mini hydro power development was thought of as an option to provide electricity to these areas. The Mini Hydro Department of National Electricity Board (MHD) was then formed to undertake the task of planning, developing and implementing mini hydro projects to meet this government aspiration. Table 1 shows the list of projects identified and implemented and its status

  20. The development and evaluation of mini-GEMs - short, focused, online e-learning videos in geriatric medicine.

    Science.gov (United States)

    Garside, Mark J; Fisher, James M; Blundell, Adrian G; Gordon, Adam L

    2018-01-01

    Mini Geriatric E-Learning Modules (Mini-GEMs) are short, focused, e-learning videos on geriatric medicine topics, hosted on YouTube, which are targeted at junior doctors working with older people. This study aimed to explore how these resources are accessed and used. The authors analyzed the viewing data from 22 videos published over the first 18 months of the Mini-GEM project. We conducted a focus group of U.K. junior doctors considering their experiences with Mini-GEMS. The Mini-GEMs were viewed 10,291 times over 18 months, equating to 38,435 minutes of total viewing time. The average viewing time for each video was 3.85 minutes. Learners valued the brevity and focused nature of the Mini-GEMs and reported that they watched them in a variety of settings to supplement clinical experiences and consolidate learning. Watching the videos led to an increase in self-reported confidence in managing older patients. Mini-GEMs can effectively disseminate clinical teaching material to a wide audience. The videos are valued by junior doctors due to their accessibility and ease of use.

  1. Mathematics authentic assessment on statistics learning: the case for student mini projects

    Science.gov (United States)

    Fauziah, D.; Mardiyana; Saputro, D. R. S.

    2018-03-01

    Mathematics authentic assessment is a form of meaningful measurement of student learning outcomes for the sphere of attitude, skill and knowledge in mathematics. The construction of attitude, skill and knowledge achieved through the fulfilment of tasks which involve active and creative role of the students. One type of authentic assessment is student mini projects, started from planning, data collecting, organizing, processing, analysing and presenting the data. The purpose of this research is to learn the process of using authentic assessments on statistics learning which is conducted by teachers and to discuss specifically the use of mini projects to improving students’ learning in the school of Surakarta. This research is an action research, where the data collected through the results of the assessments rubric of student mini projects. The result of data analysis shows that the average score of rubric of student mini projects result is 82 with 96% classical completeness. This study shows that the application of authentic assessment can improve students’ mathematics learning outcomes. Findings showed that teachers and students participate actively during teaching and learning process, both inside and outside of the school. Student mini projects also provide opportunities to interact with other people in the real context while collecting information and giving presentation to the community. Additionally, students are able to exceed more on the process of statistics learning using authentic assessment.

  2. Medical linear accelerator mounted mini-beam collimator: design, fabrication and dosimetric characterization.

    Science.gov (United States)

    Cranmer-Sargison, G; Crewson, C; Davis, W M; Sidhu, N P; Kundapur, V

    2015-09-07

    The goal of this work was to design, build and experimentally characterize a linear accelerator mounted mini-beam collimator for use at a nominal 6 MV beam energy. Monte Carlo simulation was used in the design and dosimetric characterization of a compact mini-beam collimator assembly mounted to a medical linear accelerator. After fabrication, experimental mini-beam dose profiles and central axis relative output were measured and the results used to validate the simulation data. The simulation data was then used to establish traceability back to an established dosimetric code of practice. The Monte Carlo simulation work revealed that changes in collimator blade width have a greater influence on the valley-to-peak dose ratio than do changes in blade height. There was good agreement between the modeled and measured profile data, with the exception of small differences on either side of the central peak dose. These differences were found to be systematic across all depths and result from limitations associated with the collimator fabrication. Experimental mini-beam relative output and simulation data agreed to better than ± 2.0%, which is well within the level of uncertainty required for dosimetric traceability of non-standard field geometries. A mini-beam collimator has now been designed, built and experimentally characterized for use with a commercial linear accelerator operated at a nominal 6 MV beam energy.

  3. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

    Science.gov (United States)

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic.

  4. The Mini-EUSO telescope on the ISS

    Energy Technology Data Exchange (ETDEWEB)

    Scotti, Valentina, E-mail: scottiv@na.infn.it; Osteria, Giuseppe

    2017-02-11

    The Mini-EUSO project aims to perform observations of the UV-light night emission from Earth. The UV background produced in atmosphere is a key measurement for any experiment aiming at the observation of Extreme Energy Cosmic Rays (EECR) from space, the most energetic component of the cosmic radiation. The Mini-EUSO instrument will be placed within the International Space Station (ISS) in the Russian Module and measures through a UV transparent window. The instrument comprises a compact telescope with a large field of view, based on an optical system employing two Fresnel lenses for increased light collection. The light is focused onto an array of photo-multipliers and the resulting signal is converted into digital, processed and stored via the electronics subsystems on-board. The instrument is designed and built by the members of the JEM-EUSO collaboration. JEM-EUSO is a wide-angle refractive UV telescope being proposed for attachment to the ISS, which has been designed to address basic problems of fundamental physics and high-energy astrophysics investigating the nature of cosmic rays with energies above 10{sup 20} eV. Mini-EUSO will be able to study beside EECRs a wide range of scientific phenomena including atmospheric physics, strange quark matter and bioluminescence. The mission is approved by the Italian Space Agency and the Russian Space Agency. Scientific, technical and programmatic aspects of this project will be described.

  5. Aspects of alcohol use disorder affecting social cognition as assessed using the Mini Social and Emotional Assessment (mini-SEA).

    Science.gov (United States)

    Cox, Sharon; Bertoux, Maxime; Turner, John J D; Moss, Antony; Locker, Kirsty; Riggs, Kevin

    2018-04-10

    Alcohol Use Disorder (AUD) is associated with problems with processing complex social scenarios. Little is known about the relationship between distinct AUD-related factors (e.g., years of problematic drinking), aspects of cognitive function and dysfunction in individuals diagnosed with AUD, and the relative impact these may have on social cognition. To explore differences in social cognition between a group of participants diagnosed with AUD and controls, using a clinical measure, the Mini Social and Emotional Assessment (mini-SEA). The mini-SEA was used to evaluate social and emotional understanding through a facial emotional recognition task and by utilising a series of social scenes some of which contain a faux pas (social error). Eighty-five participants (individuals with AUD and controls) completed demographic questions and a general cognitive and social cognitive test battery over three consecutive days. Between group analyses revealed that the participants with AUD performed less well on the faux pas test, and differences were also revealed in the emotional facial recognition task. Years of problematic alcohol consumption was the strongest predictor of poor ToM reasoning. These results suggest a strong link between AUD chronicity and social cognition, though the direction of this relationship needs further elucidation. This may be of clinical relevance to abstinence and relapse management, as basic social cognition skills and ability to maintain interpersonal relationships are likely to be crucial to recovery. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Design considerations, architecture, and use of the Mini-Sentinel distributed data system.

    Science.gov (United States)

    Curtis, Lesley H; Weiner, Mark G; Boudreau, Denise M; Cooper, William O; Daniel, Gregory W; Nair, Vinit P; Raebel, Marsha A; Beaulieu, Nicolas U; Rosofsky, Robert; Woodworth, Tiffany S; Brown, Jeffrey S

    2012-01-01

    We describe the design, implementation, and use of a large, multiorganizational distributed database developed to support the Mini-Sentinel Pilot Program of the US Food and Drug Administration (FDA). As envisioned by the US FDA, this implementation will inform and facilitate the development of an active surveillance system for monitoring the safety of medical products (drugs, biologics, and devices) in the USA. A common data model was designed to address the priorities of the Mini-Sentinel Pilot and to leverage the experience and data of participating organizations and data partners. A review of existing common data models informed the process. Each participating organization designed a process to extract, transform, and load its source data, applying the common data model to create the Mini-Sentinel Distributed Database. Transformed data were characterized and evaluated using a series of programs developed centrally and executed locally by participating organizations. A secure communications portal was designed to facilitate queries of the Mini-Sentinel Distributed Database and transfer of confidential data, analytic tools were developed to facilitate rapid response to common questions, and distributed querying software was implemented to facilitate rapid querying of summary data. As of July 2011, information on 99,260,976 health plan members was included in the Mini-Sentinel Distributed Database. The database includes 316,009,067 person-years of observation time, with members contributing, on average, 27.0 months of observation time. All data partners have successfully executed distributed code and returned findings to the Mini-Sentinel Operations Center. This work demonstrates the feasibility of building a large, multiorganizational distributed data system in which organizations retain possession of their data that are used in an active surveillance system. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Mini-interfacial fracture toughness as a new validated enamel-bonding effectiveness test.

    Science.gov (United States)

    Pongprueksa, Pong; De Munck, Jan; Barreto, Bruno C; Karunratanakul, Kavin; Van Meerbeek, Bart

    2016-09-01

    Today׳s most commonly applied bonding effectiveness tests are criticized for their high variability and low reliability, the latter in particular with regard to measuring the actual strength of the adhesive interface. in continuation of previous research conducted at dentin, we hereby aimed to validate the novel mini-interfacial fracture toughness (mini-iFT) test on its applicability to assess bonding effectiveness of contemporary adhesives when bonded to enamel. The 3-step etch&rinse (E&R) adhesive OptiBond FL (Kerr), the 2-step self-etch (SE) adhesive Clearfil SE Bond (Kuraray Noritake) and the two multi-mode adhesives Clearfil S(3) Bond Plus (Kuraray Noritake) and Scotchbond Universal (3M ESPE), both used following a 2-step E&R and 1-step SE mode, were applied to clinically relevant, flattened enamel surfaces. A composite (Filtek Z100; 3M ESPE) build-up was made in layers. After 1-week water storage at 37°C, all specimens were sectioned perpendicular to the interface to obtain rectangular sticks. A mini-iFT notch was prepared at the adhesive-enamel interface using a thin diamond blade under water cooling. Finally, the specimens were loaded in a 4-point bending test until failure. the mini-iFT onto human enamel was significantly higher for the adhesives applied in E&R mode versus those applied in SE mode. The lowest mini-iFT was found for the adhesives applied following a 1-step SE approach. SEM fracture analysis revealed that all fractures originated at the adhesive-enamel interface and that the induced crack propagated preferentially along this interface. mini-iFT appeared a valid alternative method to assess the mechanical properties of adhesive-enamel interfaces. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Mini-Conference on the First Microns of the First Wall

    Energy Technology Data Exchange (ETDEWEB)

    Stotler, D. P.; Rognlien, T. D.; Krasheninnikov, S. I.

    2008-03-20

    Interactions between plasmas and their surrounding materials (plasma facing components) are of great interest to present and future magnetic fusion experiments, and ITER [ITER Physics Basis Editors, ITER Physics Exper Group Chairs, ITER Joint Central Team, and Physics Inte gration Unit, Nucl. Fusion 39, 2137 (1999)] in particular. This interest is the result of concerns with the survivability of these materials, as well as the impact of these interactions back on the plasma. These interactions begin on the surface, but can have consequences a few microns into the material.This mini-conference on these "first microns" was designed to bring to the Division of Plasma Physics Meeting experts on these topics who would otherwise not attend. At the same time, the mini-conference was intended to expose the broader fusion community to these issues. The mini-conference covered in three, half-day sessions the topics of lithium coatings and surfaces, mixed materials characteristics, and issues associated with graphite.

  9. Mini-Conference on the First Microns of the First Wall

    International Nuclear Information System (INIS)

    Stotler, D.P.; Rognlien, T.D.; Krasheninnikov, S.I.

    2008-01-01

    Interactions between plasmas and their surrounding materials (plasma facing components) are of great interest to present and future magnetic fusion experiments, and ITER (ITER Physics Basis Editors, ITER Physics Exper Group Chairs, ITER Joint Central Team, and Physics Integration Unit, Nucl. Fusion 39, 2137 (1999)) in particular. This interest is the result of concerns with the survivability of these materials, as well as the impact of these interactions back on the plasma. These interactions begin on the surface, but can have consequences a few microns into the material. This mini-conference on these 'first microns' was designed to bring to the Division of Plasma Physics Meeting experts on these topics who would otherwise not attend. At the same time, the mini-conference was intended to expose the broader fusion community to these issues. The mini-conference covered in three, half-day sessions the topics of lithium coatings and surfaces, mixed materials characteristics, and issues associated with graphite

  10. MiniWall Tool for Analyzing CFD and Wind Tunnel Large Data Sets

    Science.gov (United States)

    Schuh, Michael J.; Melton, John E.; Stremel, Paul M.

    2017-01-01

    It is challenging to review and assimilate large data sets created by Computational Fluid Dynamics (CFD) simulations and wind tunnel tests. Over the past 10 years, NASA Ames Research Center has developed and refined a software tool dubbed the MiniWall to increase productivity in reviewing and understanding large CFD-generated data sets. Under the recent NASA ERA project, the application of the tool expanded to enable rapid comparison of experimental and computational data. The MiniWall software is browser based so that it runs on any computer or device that can display a web page. It can also be used remotely and securely by using web server software such as the Apache HTTP server. The MiniWall software has recently been rewritten and enhanced to make it even easier for analysts to review large data sets and extract knowledge and understanding from these data sets. This paper describes the MiniWall software and demonstrates how the different features are used to review and assimilate large data sets.

  11. Calling all LEGO lovers! Add a mini control room to your collection

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    The mini LHC Lego project launched in March (see here) now has almost 6,000 supporters - well on its way to the 10,000 votes needed for it to (hopefully!) hit store shelves. This week, the project added a new feature to its line: a mini control centre! The new LEGO Control centre, featuring operators "Kerstin" and "Marco".   The mini LHC project is the brainchild of ATLAS PhD student Nathan Readioff, who designed Lego replicas of the LHC and the ALICE, ATLAS, CMS and LHCb experiments on a micro scale. Each detector model is small enough to fit in the palm of your hand but crammed with detailed internal systems revealed by cutaway walls. Every major detector component is represented by a Lego piece. Now, Nathan has created a control centre to complement the mini LHC project. This would be an add-on feature for Lego’s consideration, should they decide to develop the accelerator into a box set. “The control centre is ...

  12. Lateral forces exerted through ball or bar attachments in relation to the inclination of mini-implant underneath overdentures: in vitro study.

    Science.gov (United States)

    Takagaki, Kyozo; Gonda, Tomoya; Maeda, Yoshinobu

    2015-09-01

    Lateral force to mini-implants should be avoided because mini-implants are weak mechanically because of its small diameter. Overdentures retained by mini-implants are usually formed using ball attachments. However, bar attachments can offer the advantage of splinting the mini-implants. This study examined the effect of attachments in withstanding these lateral forces in tilted mini-implants of overdentures. Strain gauges were attached to the mini-implants (2.5 × 18 mm) embedded in an acrylic resin block. Two mini-implants were inserted vertically (Control) or with one mini-implant inclined at 10° or 20° (10-inclined and 20-inclined, respectively). The female portions of the attachments were secured to the denture base. A prefabricated ball attachment and CAD/CAM-fabricated bar attachment were compared. A vertical load of 49 N was applied to the occlusal surface at a distance 10 mm away from the center of two mini-implants. The lateral force borne by the mini-implants was measured via the attached strain gauge. Mann-Whitney U-test and an analysis of Bonferroni correction were used to compare differences between the two attachments and among the three models (P < 0.05). The lateral force exerted to the inclined mini-implant was significantly greater than that borne by a vertical mini-implant for both attachment types. The lateral force on the 20° inclined mini-implants with bar attachments was smaller than that on mini-implants with ball attachments. Inclined mini-implants are subjected to greater stresses than vertical ones, and a bar attachment can reduce the lateral forces borne by the mini-implant when one mini-implant inclined at 20°. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Journal of Pharmacy & Bioresources: Journal Sponsorship

    African Journals Online (AJOL)

    Journal of Pharmacy & Bioresources: Journal Sponsorship. Journal Home > About the Journal > Journal of Pharmacy & Bioresources: Journal Sponsorship. Log in or Register to get access to full text downloads.

  14. Ressources minières en Afrique : Quelle réglementation pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ressources minières en Afrique : Quelle réglementation pour le développement ? Couverture du livre Ressources minières en Afrique : Quelle réglementation pour le développement ? Directeur(s):. Bonnie Campbell. Maison(s) d'édition: Presses de l'Université du Québec, CRDI. 6 juillet 2009. ISBN : 9782760525214.

  15. Error Correction of Meteorological Data Obtained with Mini-AWSs Based on Machine Learning

    Directory of Open Access Journals (Sweden)

    Ji-Hun Ha

    2018-01-01

    Full Text Available Severe weather events occur more frequently due to climate change; therefore, accurate weather forecasts are necessary, in addition to the development of numerical weather prediction (NWP of the past several decades. A method to improve the accuracy of weather forecasts based on NWP is the collection of more meteorological data by reducing the observation interval. However, in many areas, it is economically and locally difficult to collect observation data by installing automatic weather stations (AWSs. We developed a Mini-AWS, much smaller than AWSs, to complement the shortcomings of AWSs. The installation and maintenance costs of Mini-AWSs are lower than those of AWSs; Mini-AWSs have fewer spatial constraints with respect to the installation than AWSs. However, it is necessary to correct the data collected with Mini-AWSs because they might be affected by the external environment depending on the installation area. In this paper, we propose a novel error correction of atmospheric pressure data observed with a Mini-AWS based on machine learning. Using the proposed method, we obtained corrected atmospheric pressure data, reaching the standard of the World Meteorological Organization (WMO; ±0.1 hPa, and confirmed the potential of corrected atmospheric pressure data as an auxiliary resource for AWSs.

  16. Search for Sterile Neutrinos Using the MiniBooNE Beam

    Energy Technology Data Exchange (ETDEWEB)

    Sorel, Michel [Columbia Univ., New York, NY (United States)

    2005-01-01

    The possible existence of light sterile neutrinos in Nature is motivated, and the prospects to extend sterile neutrino searches beyond current limits is substantiated, using the MiniBooNE neutrino beam and detector at Fermilab. We report on the neutrino flux predictions for the MiniBooNE experiment, on the characterization of the charged-current, quasi-elastic interactions of muon neutrinos ({nu}{sub {mu}}n {yields} {mu}{sup -}p) observed, and on the experiment's sensitivity to sterile neutrinos via muon neutrino disappearance.

  17. Towards the theory of mini black holes with subplanckian mass

    International Nuclear Information System (INIS)

    Zeldovich, Y.B.

    1984-01-01

    This chapter phenomenologically examines the question of the decay (evaporation) and formation of mini black holes. Neutral black holes are considered, having neither electrical charge, nor color and weak charge, so that no long range vector field is present beyond gravitational radius. Topics considered include thermodynamic equilibrium and the formation of light black holes, the formation and decay of light black holes in the big bang, and the difficulties of the theory. It is emphasized that the existence of mini black holes has not yet been proven

  18. The ASTRI Mini-Array Science Case

    Science.gov (United States)

    Vercellone, Stefano; Catalano, O.; Maccarone, M.; Stamerra, A.; Di Pierro, F.; Vallania, P.; Canestrari, R.; Bonnoli, G.; Pareschi, G.; Tosti, G.; Caraveo, P.; ASTRI Collaboration

    2013-04-01

    ASTRI is a flagship project of the Italian Ministry of Education, University and Research. Within this framework, INAF is currently developing an end-to-end prototype of the CTA small-size telescope in a dual-mirror configuration (SST-2M) to be tested under field conditions, and scheduled to start data acquisition in 2014. A remarkable improvement in terms of performance could come from the operation, in 2016, of a SST-2M mini-array, composed by a few SST-2M telescopes and to be placed at final CTA Southern Site. The SST mini-array will be able to study in great detail relatively bright sources (a few x10E-12 erg/cm2/s at 10 TeV) with an angular resolution of a few arcmin and an energy resolution of about 10 - 15%. Moreover, thanks to the array approach, it will be possible to verify the wide FoV performance to detect very high energy showers with the core located at a distance up to 500 m, to compare the mini-array performance with the Monte Carlo expectations by means of deep observations of few selected targets, and to perform the first CTA science, with its first solid detections during the first year of operation. Prominent sources such as extreme blazars (1ES 0229+200), nearby well-known BL Lac objects (MKN 501) and radio-galaxies, galactic pulsar wind nebulae (Crab Nebula, Vela-X), supernovae remnants (Vela-junior, RX J1713.7-3946) and microquasars (LS 5039), as well as the Galactic Center can be observed in a previously unexplored energy range, in order to investigate the electron acceleration and cooling, relativistic and non relativistic shocks, the search for cosmic-ray (CR) Pevatrons, the study of the CR propagation, and the impact of the extragalactic background light on the spectra of the sources.

  19. MINI-TRAC code: a driver program for assessment of constitutive equations of two-fluid model

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Abe, Yutaka; Ohnuki, Akira; Murao, Yoshio

    1991-05-01

    MINI-TRAC code, a driver program for assessment of constitutive equations of two-fluid model, has been developed to perform assessment and improvement of constitutive equations of two-fluid model widely and efficiently. The MINI-TRAC code uses one-dimensional conservation equations for mass, momentum and energy based on the two-fluid model. The code can work on a personal computer because it can be operated with a core memory size less than 640 KB. The MINI-TRAC code includes constitutive equations of TRAC-PF1/MOD1 code, TRAC-BF1 code and RELAP5/MOD2 code. The code is modulated so that one can easily change constitutive equations to perform a test calculation. This report is a manual of the MINI-TRAC code. The basic equations, numerics, constitutive, equations included in the MINI-TRAC code will be described. The user's manual such as input description will be presented. The program structure and contents of main variables will also be mentioned in this report. (author)

  20. A mini-exhibition with maximum content

    CERN Multimedia

    Laëtitia Pedroso

    2011-01-01

    The University of Budapest has been hosting a CERN mini-exhibition since 8 May. While smaller than the main travelling exhibition it has a number of major advantages: its compact design alleviates transport difficulties and makes it easier to find suitable venues in the Member States. Its content can be updated almost instantaneously and it will become even more interactive and high-tech as time goes by.   The exhibition on display in Budapest. The purpose of CERN's new mini-exhibition is to be more interactive and easier to install. Due to its size, the main travelling exhibition cannot be moved around quickly, which is why it stays in the same country for 4 to 6 months. But this means a long waiting list for the other Member States. To solve this problem, the Education Group has designed a new exhibition, which is smaller and thus easier to install. Smaller maybe, but no less rich in content, as the new exhibition conveys exactly the same messages as its larger counterpart. However, in the slimm...

  1. Comparison of topical and infiltration anesthesia for orthodontic mini-implant placement

    Directory of Open Access Journals (Sweden)

    Matheus Miotello Valieri

    2014-04-01

    Full Text Available Objective: To compare the acceptability and effectiveness of topical and infiltration anesthesia for placement of mini-implants used as temporary anchorage devices. Methods: The sample comprised 40 patients, 17 males and 23 females, whose mean age was 26 years old and who were all undergoing orthodontic treatment and in need for anchorage reinforcement. Mini-implants were bilaterally placed in the maxilla of all individuals, with infiltration anesthesia on one side and topical anesthesia on the other. These 40 patients completed two questionnaires, one before and another after mini-implant placement and pain was measured through a visual analog scale (VAS. The data collected were analyzed using descriptive statistics and the measurements of pain were compared by means of the non-parametric test of Mann-Whitney. Results: It was found that 60% of patients felt more comfortable with the use of topical anesthesia for mini-implant placement; 72.5% of patients described the occurrence of pressure during placement of the anchorage device as the most unpleasant sensation of the entire process; 62.5% of patients felt more pain with the use of topical anesthesia. Conclusion: It was concluded that patients had less pain with the use of infiltration anesthesia, and also preferred this type of anesthetic.

  2. Rapid assessment of tinnitus-related psychological distress using the Mini-TQ.

    Science.gov (United States)

    Hiller, Wolfgang; Goebel, Gerhard

    2004-01-01

    The aim of this study was to develop an abridged version of the Tinnitus Questionnaire (TQ) to be used as a quick tool for the assessment of tinnitus-related psychological distress. Data from 351 inpatients and 122 outpatients with chronic tinnitus were used to analyse item statistics and psychometric properties. Twelve items with an optimal combination of high item-total correlations, reliability and sensitivity in assessing changes were selected for the Mini-TQ. Correlation with the full TQ was >0.90, and test-retest reliability was 0.89. Validity was confirmed by associations with general psychological symptom patterns. Treatment effects indicated by the Mini-TQ were slightly greater than those indicated by the full TQ. The Mini-TQ is recommended as a psychometrically approved and solid tool for rapid and economical assessment of subjective tinnitus distress.

  3. Effect of gamma irradiation on nutrient digestibility in SPF mini-pig

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun-Yeob [College of Animal Life Sciences , Kangwon National University, 192-1 Kangwon Avenue 1, Chuncheon, Gangwon-do 200-701 (Korea, Republic of); Cho, Sung-Back [Swine Science Division, National Institute of Animal Science, Cheonan, Chungcheongnam-do 330-801 (Korea, Republic of); Kim, Yoo-Yong [College of Agriculture and Life Science, Seoul National University, Gwanak-gu, Seoul 151-742 (Korea, Republic of); Ohh, Sang-Jip, E-mail: sjohh@kangwon.ac.k [College of Animal Life Sciences , Kangwon National University, 192-1 Kangwon Avenue 1, Chuncheon, Gangwon-do 200-701 (Korea, Republic of)

    2011-01-15

    This study was carried out to evaluate the effect of gamma irradiation on nutrient digestibility of either soy-based or milk-based diet for specific pathogen-free (SPF) mini-pigs. Gamma irradiation of the diets was done at dosage of 10 kGy with {sup 60}Co whereas autoclaving was executed at 121 {sup o}C for 20 min. Apparent crude protein digestibilities of gamma irradiated diets were higher (p<0.05) than those of autoclaved diets regardless of diet type. Digestibilities of dry matter, gross energy and total carbohydrate in the irradiated diet were higher than those of the autoclaved diet. From the results of nutrient digestibility of mini-pig diets in this study, 10 kGy gamma radiation was suggested as a convenient diet radicidation method that can minimize the decrease in nutrient digestibility on feeding to SPF mini-pigs.

  4. Advances in Autonomous Mini Robots : Proceedings of the 6-th AMiRE Symposium

    CERN Document Server

    Joaquin, Sitte; Felix, Werner

    2012-01-01

    Autonomous robots must carry out useful tasks all by themselves relying entirely on their own perceptions of their environment. The cognitive abilities required for autonomous action are largely independent of robot size, which makes mini robots attractive as artefacts for research, education and entertainment. Autonomous mini robots must be small enough for experimentation on a desktop or a small laboratory.  They must be easy to carry and safe for interaction with humans. They must not be expensive. Mini robot designers have to work at the leading edge of technology so that their creations can carry out purposeful autonomic action under these constraints. Since 2001 researchers have met every two years for an international symposium to report on the advances achieved in Autonomous Mini  Robots for Research and Edutainment (AMiRE). The AMiRE Symposium is a single track conference that offers ample opportunities for discussion and exchange of ideas. This volume contains the contributed papers of the 2011 AM...

  5. Mini-Uav LIDAR for Power Line Inspection

    Science.gov (United States)

    Teng, G. E.; Zhou, M.; Li, C. R.; Wu, H. H.; Li, W.; Meng, F. R.; Zhou, C. C.; Ma, L.

    2017-09-01

    Light detection and ranging (LIDAR) system based on unmanned aerial vehicles (UAVs) recently are in rapid advancement, meanwhile portable and flexible mini-UAV-borne laser scanners have been a hot research field, especially for the complex terrain survey in the mountains and other areas. This study proposes a power line inspection system solution based on mini-UAV-borne LIDAR system-AOEagle, developed by Academy of Opto-Electronics, Chinese Academy of Sciences, which mounted on a Multi-rotor unmanned aerial vehicle for complex terrain survey according to real test. Furthermore, the point cloud data was explored to validate its applicability for power line inspection, in terms of corridor and line laser point clouds; deformation detection of power towers, etc. The feasibility and advantages of AOEagle have been demonstrated by the promising results based on the real-measured data in the field of power line inspection.

  6. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Celha Borges Costa Alves

    Full Text Available ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm, Neodent(tm and SIN(tm were separately immersed in artificial saliva (pH 6.76 for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM. The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. Results: No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm, Neodent(tm and SIN(tm present high corrosion resistance and are not cytotoxic.

  7. Upside-down stomach – results of mini-invasive surgical therapy

    Directory of Open Access Journals (Sweden)

    Cestmir Neoral

    2011-12-01

    Full Text Available Aim: The authors evaluate the results of mini-invasive therapy in patients diagnosed with upside-down stomach. Material and methods: From 1998 to 2008, a total of 27 patients diagnosed with upside-down stomach were surgicallytreated at the 1st Department of Surgery, University Hospital Olomouc. Before the operation, patients wereexamined endoscopically and a barium swallow was performed. In all 27 patients (100%, the operation was performedelectively laparoscopically. The principle of the operation in all cases was reposition of the stomach into theabdominal cavity, resection of the hernial sac and hiatoplasty. In addition, in 15 patients (56% with reflux symptomsor endoscopic findings of reflux oesophagitis, fundoplication in Nissen’s modification was also performed. Fundopexywas indicated in 12 patients (44%. Results: In all patients (100%, the operation was performed mini-invasively; conversion to an open procedure wasnever necessary. In 3 cases (11%, the left pleural cavity was opened during the operation; this was treated by introducinga chest drain. The operation mortality in the patient set was zero; morbidity was 11%. A year after the operation,patients were re-examined, and follow-up endoscopy and barium swallow were performed. Conclusions: In all patients diagnosed with upside-down stomach, surgical treatment is indicated due to the risk ofdeveloping severe complications. Mini-invasive surgical therapy in the hands of an experienced surgeon is a safe procedurewhich offers patients all the benefits of mini-invasive therapy with promising short- and long-term results.

  8. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    Science.gov (United States)

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  9. Assessment of functioning in patients with schizophrenia and schizoaffective disorder with the Mini-ICF-APP: a validation study in Italy.

    Science.gov (United States)

    Pinna, Federica; Fiorillo, Andrea; Tusconi, Massimo; Guiso, Beatrice; Carpiniello, Bernardo

    2015-01-01

    The aim of the study was to evaluate validity of the Italian Mini-ICF-APP (Mini-ICF Rating for Limitations of Activities and Participation in Psychological Disorders) in schizophrenia and related disorders. 74 outpatients affected by schizophrenia or schizoaffective disorders attending a University-based community mental health centre were recruited to the study. All participants underwent comprehensive evaluation using standardized instruments to assess clinical, neurocognitive and functional status. Concurrent validity of Mini-ICF-APP was evaluated and compared to severity scores obtained using the Clinical Global Impression-Schizophrenia scale (CGI-SCH), Positive and Negative Syndrome scale (PANSS), Mini Mental State Examination test (MMSE), Brief Assessment of Cognition in Schizophrenia scale (BACS) and Personal and Social Performance scale (PSP). Construct validity was evaluated by comparing scores obtained at Mini-ICF-APP by remitted versus non-remitted patients, and by recovered versus unrecovered patients. Discriminant validity was evaluated comparing scores on Mini-ICF-APP and Subjective Well-being (SWN) scale. the total score and 12 out of the 13 Mini-ICF-APP items correlated significantly with total score at PSP; Mini-ICF-App total score was moreover significantly correlated with total scores at CGI-SCH, PANSS, MMSE, as well as with several BACS items. Total scores obtained at Mini-ICF-APP were significantly higher among remitted and recovered patients. No relevant correlations were found between scores of Mini-ICF-APP and SWN scales. The total score and 12 out of the 13 Mini-ICF-APP items correlated significantly with total score at PSP; Mini-ICF-App total score was moreover significantly correlated with total scores at CGI-SCH, PANSS, MMSE, as well as with several BACS items. Total scores obtained at Mini-ICF-APP were significantly higher among remitted and recovered patients. No relevant correlations were found between scores of Mini-ICF-APP and SWN

  10. Mini Seminar on Form Filling Ability of Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2005-01-01

    The Nordic mini-seminar “Form Filling Ability of Self-Compacting Concrete” took place on 3-4 November 2003 at the Danish Technological Institute in Taastrup, Denmark. The mini-seminar gathered 12 participants from Finland, Sweden, Norway and Denmark. The objective was to present and discuss recent...... developments of Self-Compacting Concrete in the Nordic countries. In general, the seminar included results and observations on the effect of fresh concrete behaviour, casting technique, and organisation on site on the filling ability, passing ability, and surface quality. The seminar had participants from...

  11. Analysis of MINIE2013 Explosion Air-Blast Data

    Energy Technology Data Exchange (ETDEWEB)

    Schnurr, Julie M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of Hawaii, Manoa, HI (United States); Rodgers, Arthur J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kim, Keehoon [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ford, Sean R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Ramirez, Abelardo L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-10-14

    We report analysis of air-blast overpressure measurements from the MINIE2013 explosive experiments. The MINIE2013 experiment involved a series of nearly 70 near-surface (height-ofburst, HOB, ranging from -1 to +4 m) low-yield (W=2-20 kg TNT equivalent) chemical highexplosives tests that were recorded at local distances (230 m – 28.5 km). Many of the W and HOB combinations were repeated, allowing for quantification of the variability in air-blast features and corresponding yield estimates. We measured canonical signal features (peak overpressure, impulse per unit area, and positive pulse duration) from the air-blast data and compared these to existing air-blast models. Peak overpressure measurements showed good agreement with the models at close ranges but tended to attenuate more rapidly at longer range (~ 1 km), which is likely caused by upward refraction of acoustic waves due to a negative vertical gradient of sound speed. We estimated yields of the MINIE2013 explosions using the Integrated Yield Determination Tool (IYDT). Errors of the estimated yields were on average within 30% of the reported yields, and there were no significant differences in the accuracy of the IYDT predictions grouped by yield. IYDT estimates tend to be lower than ground truth yields, possibly because of reduced overpressure amplitudes by upward refraction. Finally, we report preliminary results on a development of a new parameterized air-blast waveform.

  12. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  13. The reliability, validity, and applicability of an English language version of the Mini-ICF-APP.

    Science.gov (United States)

    Molodynski, Andrew; Linden, Michael; Juckel, George; Yeeles, Ksenija; Anderson, Catriona; Vazquez-Montes, Maria; Burns, Tom

    2013-08-01

    This study aimed at establishing the validity and reliability of an English language version of the Mini-ICF-APP. One hundred and five patients under the care of secondary mental health care services were assessed using the Mini-ICF-APP and several well-established measures of functioning and symptom severity. 47 (45 %) patients were interviewed on two occasions to ascertain test-retest reliability and 50 (48 %) were interviewed by two researchers simultaneously to determine the instrument's inter-rater reliability. Occupational and sick leave status were also recorded to assess construct validity. The Mini-ICF-APP was found to have substantial internal consistency (Chronbach's α 0.869-0.912) and all 13 items correlated highly with the total score. Analysis also showed that the Mini-ICF-APP had good test-retest (ICC 0.832) and inter-rater (ICC 0.886) reliability. No statistically significant association with length of sick leave was found, but the unemployed scored higher on the Mini ICF-APP than those in employment (mean 18.4, SD 9.1 vs. 9.4, SD 6.4, p Mini-ICF-APP correlated highly with the other measures of illness severity and functioning considered in the study. The English version of the Mini-ICF-APP is a reliable and valid measure of disorders of capacity as defined by the International Classification of Functioning. Further work is necessary to establish whether the scale could be divided into sub scales which would allow the instrument to more sensitively measure an individual's specific impairments.

  14. Introducing a Low-Cost Mini-Uav for - and Multispectral-Imaging

    Science.gov (United States)

    Bendig, J.; Bolten, A.; Bareth, G.

    2012-07-01

    The trend to minimize electronic devices also accounts for Unmanned Airborne Vehicles (UAVs) as well as for sensor technologies and imaging devices. Consequently, it is not surprising that UAVs are already part of our daily life and the current pace of development will increase civil applications. A well known and already wide spread example is the so called flying video game based on Parrot's AR.Drone which is remotely controlled by an iPod, iPhone, or iPad (http://ardrone.parrot.com). The latter can be considered as a low-weight and low-cost Mini-UAV. In this contribution a Mini-UAV is considered to weigh less than 5 kg and is being able to carry 0.2 kg to 1.5 kg of sensor payload. While up to now Mini-UAVs like Parrot's AR.Drone are mainly equipped with RGB cameras for videotaping or imaging, the development of such carriage systems clearly also goes to multi-sensor platforms like the ones introduced for larger UAVs (5 to 20 kg) by Jaakkolla et al. (2010) for forestry applications or by Berni et al. (2009) for agricultural applications. The problem when designing a Mini-UAV for multi-sensor imaging is the limitation of payload of up to 1.5 kg and a total weight of the whole system below 5 kg. Consequently, the Mini-UAV without sensors but including navigation system and GPS sensors must weigh less than 3.5 kg. A Mini-UAV system with these characteristics is HiSystems' MK-Okto (www.mikrokopter.de). Total weight including battery without sensors is less than 2.5 kg. Payload of a MK-Okto is approx. 1 kg and maximum speed is around 30 km/h. The MK-Okto can be operated up to a wind speed of less than 19 km/h which corresponds to Beaufort scale number 3 for wind speed. In our study, the MK-Okto is equipped with a handheld low-weight NEC F30IS thermal imaging system. The F30IS which was developed for veterinary applications, covers 8 to 13 μm, weighs only 300 g, and is capturing the temperature range between -20 °C and 100 °C. Flying at a height of 100 m, the camera

  15. Mini-percutaneous nephrolithotomy for stones in anomalous-kidneys: a prospective study.

    Science.gov (United States)

    Khadgi, Sanjay; Shrestha, Babu; Ibrahim, Hamdy; Shrestha, Sunil; ElSheemy, Mohammed S; Al-Kandari, Ahmed M

    2017-08-01

    To evaluate safety and efficacy of minipercutaneous nephrolithotomy (Mini-PNL) in management of stones in different types of renal anomalies. Patients with stones ≥2 cm or SWL-resistant stones in anomalous-kidneys treated by Mini-PNL between March 2010 and September 2012 were included prospectively. Mini-PNL was done under regional anesthesia in prone position with fluoroscopic guidance through 18 Fr sheath using semirigid ureteroscope (8.5/11.5 Fr) and pneumatic lithotripter. All patients were followed-up for 2-3 years. Stone-free rate was defined as absence of residual fragments ≥2 mm. Student-T, Mann-Whitney, Chi square (χ 2 ), Fisher-exact, one way ANOVA or Kruskal-Wallis test were used for analysis. Mini-PNL was performed for 59 patients (20 horseshoe, 15 malrotated, 7 polycystic, 13 duplex and 4 ectopic pelvic-kidneys). Mean age was 40.18 ± 12.75 (14-78) years. Mean stone burden was 31.72 ± 21.43 (7.85-141.3) mm 2 . Two tracts were required in 7 (11.9 %) patients. Tubeless Mini-PNL with double-J insertion was performed in all patients except two. Operative time was 50.17 ± 18.73 (15-105) min. Hemoglobin loss was 0.44 ± 0.30 (0-1.4) g/dL. Complications were reported in 15 (25.4 %) patients. No pleural injury, sepsis, perinephric-collection or renal-pelvis perforation were reported. Stone-free rate was 89.8 % (converted to open-surgery in one patient, second-look PNL in two patients, auxiliary SWL in three patients). Stone-free rate improved to 98.3 % after retreatment and auxiliary SWL. Site of puncture was mostly upper calyceal in horseshoe-kidney (80 %), mid calyceal in polycystic-kidney (85.7 %) and lower calyceal in duplex-kidney (46.2 %). Punctures were also significantly infracostal in horseshoe-kidney (100 %) and supracostal in both duplex (53.8 %) and malrotated-kidneys (66.7 %). Mini-PNL is safe for management of stones in anomalous-kidney with SFR comparable to standard-PNL but with less complications.

  16. Mini vs standard percutaneous nephrolithotomy for renal stones: a comparative study.

    Science.gov (United States)

    ElSheemy, Mohammed S; Elmarakbi, Akram A; Hytham, Mohammed; Ibrahim, Hamdy; Khadgi, Sanjay; Al-Kandari, Ahmed M

    2018-03-16

    To compare the outcome of mini-percutaneous nephrolithotomy (Mini-PNL) versus standard-PNL for renal stones. Retrospective study was performed between March 2010 and May 2013 for patients treated by Mini-PNL or standard-PNL through 18 and 30 Fr tracts, respectively, using pneumatic lithotripsy. Semirigid ureteroscope (8.5/11.5 Fr) was used for Mini-PNL and 24 Fr nephroscope for standard-PNL. Both groups were compared in stone free rate(SFR), complications and operative time using Student-t, Mann-Whitney, Chi square or Fisher's exact tests as appropriate in addition to logistic regression analysis. P PNL (378) and standard-PNL (151) were nearly comparable in patients and stones criteria including stone burden (3.77 ± 2.21 vs 3.77 ± 2.43 cm 2 ; respectively). There was no significant difference in number of tracts or supracostal puncture. Mini-PNL had longer operative time (68.6 ± 29.09 vs 60.49 ± 11.38 min; p = 0.434), significantly shorter hospital stay (2.43 ± 1.46 vs 4.29 ± 1.28 days) and significantly higher rate of tubeless PNL (75.1 vs 4.6%). Complications were significantly higher in standard-PNL (7.9 vs 20.5%; p PNL (89.9 vs 96%; p = 0.022). This significant difference was found with multiple stones and large stone burden (> 2 cm 2 ), but the SFR was comparable between both groups with single stone or stone burden ≤ 2 cm. Logistic regression analysis confirmed significantly higher complications and SFR with standard-PNL but with significantly shorter operative time. Mini-PNL has significantly lower SFR when compared to standard-PNL (but clinically comparable) with markedly reduced complications and hospital stay. Most of cases can be performed tubeless. The significant difference in SFR was found with multiple stones or large stone burden (> 2 cm 2 ), but not with single stones or stone burden ≤ 2 cm 2 .

  17. Playing Around in the Solar System: Mini-games for Many Missions

    Science.gov (United States)

    Fisher, D. K.; Leon, N.; Fitzpatrick, A. J.; Wessen, A.

    2010-12-01

    Several NASA solar system missions will have major milestones during 2011, the Year of the Solar System. These events include launches, encounters, and orbit insertions. Other missions will continue the explorations already underway. The “Year of the Solar System Game” on The Space Place website (http://spaceplace.nasa.gov/en/kids/solar-system) brings all these efforts together in the context of the whole solar system. The game helps to build awareness of the characteristics of our solar system and some of the missions that are continuing to advance our knowledge and understanding. It is one of many educational tools being developed and deployed for the Year of the Solar System. The game is a “super-game” that encompasses a number of mission-related “mini-games.” The mini-games can be played individually, and they all contribute toward achievements in the super-game. The enveloping interface for all the games is an animated solar system. The player clicks on a planet or a moon, sees a close-up image, and reads a short paragraph about the object. If the object has been endowed with a mission mini-game, player can click on the tiny spacecraft, read about the mission, then play the game—or, if impatient, just immediately play the game (and read about the mission later, we hope). A score “page” keeps track of the player’s achievements and scores. Players earn achievements by reading about the planets, moons, asteroids, comets, and missions and by playing the mission mini-games. The game targets upper elementary age children, as does the entire Space Place website. Each mini-game, although simple, incorporates elements of the spacecrafts’ missions and their target objects. For example, in Cassini Commander, the player must navigate the Cassini spacecraft through gaps in Saturn’s rings and around Saturn’s moons. The super-game is designed to accommodate any number of mission mini-games, so we are hoping to continue to add missions and increase

  18. Development of a brief version of the Social Phobia Inventory using item response theory: the Mini-SPIN-R.

    Science.gov (United States)

    Aderka, Idan M; Pollack, Mark H; Simon, Naomi M; Smits, Jasper A J; Van Ameringen, Michael; Stein, Murray B; Hofmann, Stefan G

    2013-12-01

    The Social Phobia Inventory (SPIN) is a widely used measure in mental health settings and a 3-item version (mini-SPIN) has been developed as a screening instrument for social anxiety disorder. In the present study, we examined the psychometric properties of the SPIN and developed a brief version (mini-SPIN-R) designed to assess social anxiety severity using item response theory. Our sample included 569 individuals with social anxiety disorder who participated in 2 clinical trials and filled out a battery of self-report measures. Using a nonparametric kernel smoothing method we identified the most sensitive items of the SPIN. These 3 items comprised the mini-SPIN-R, which was found to have greater internal consistency, and to capture a greater range of symptoms compared to the mini-SPIN. The mini-SPIN-R evidenced superior convergent validity compared to the mini-SPIN and both measures had similar divergent validity. Thus, the mini-SPIN-R is a promising brief measure of social anxiety severity. Copyright © 2013. Published by Elsevier Ltd.

  19. Mini-weather shelters: statistical analysis for comparison and evaluation of efficiency

    Directory of Open Access Journals (Sweden)

    Sérgio Serafini Júnior

    2014-04-01

    Full Text Available In the context of the disciplines of climatology of the Department of Geography of University of Sao Paulo, site investigations allow students to practice climatologic analysis using electronic sensors installed in meteorological mini-shelters, designed by tutors and post graduate students. Based on the models of meteorological mini-shelters described as Tarifa (TAR, Abrigo de Baixo Custo (ABC [Shelter of Low Cost] e Quatro Águas(4AS [Four Waters], this research made a comparative analysis of registered data, using as reference the Automatic Meteorological Station installed on the premises of the Geography building. The efficiency data from these mini-shelters demonstrated that, although all presented different results in relation to the Automatic Meteorological Station (EMA, they also presented a performance very satisfactory around 80% of all sampled period, allowing the achievement of good results for use in academic and technical work.

  20. Typing of canine parvovirus isolates using mini-sequencing based single nucleotide polymorphism analysis.

    Science.gov (United States)

    Naidu, Hariprasad; Subramanian, B Mohana; Chinchkar, Shankar Ramchandra; Sriraman, Rajan; Rana, Samir Kumar; Srinivasan, V A

    2012-05-01

    The antigenic types of canine parvovirus (CPV) are defined based on differences in the amino acids of the major capsid protein VP2. Type specificity is conferred by a limited number of amino acid changes and in particular by few nucleotide substitutions. PCR based methods are not particularly suitable for typing circulating variants which differ in a few specific nucleotide substitutions. Assays for determining SNPs can detect efficiently nucleotide substitutions and can thus be adapted to identify CPV types. In the present study, CPV typing was performed by single nucleotide extension using the mini-sequencing technique. A mini-sequencing signature was established for all the four CPV types (CPV2, 2a, 2b and 2c) and feline panleukopenia virus. The CPV typing using the mini-sequencing reaction was performed for 13 CPV field isolates and the two vaccine strains available in our repository. All the isolates had been typed earlier by full-length sequencing of the VP2 gene. The typing results obtained from mini-sequencing matched completely with that of sequencing. Typing could be achieved with less than 100 copies of standard plasmid DNA constructs or ≤10¹ FAID₅₀ of virus by mini-sequencing technique. The technique was also efficient for detecting multiple types in mixed infections. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Development of a Mini-Freeze Dryer for Material-Sparing Laboratory Processing with Representative Product Temperature History.

    Science.gov (United States)

    Obeidat, Wasfy M; Sahni, Ekneet; Kessler, William; Pikal, Michael

    2018-02-01

    The goal of the work described in this publication was to evaluate a new, small, material-sparing freeze dryer, denoted as the "mini-freeze dryer or mini-FD", capable of reproducing the product temperature history of larger freeze dryers, thereby facilitating scale-up. The mini-FD wall temperatures can be controlled to mimic loading procedures and dryer process characteristics of larger dryers. The mini-FD is equipped with a tunable diode laser absorption spectroscopy (TDLAS) water vapor mass flow monitor and with other advanced process analytical technology (PAT) sensors. Drying experiments were performed to demonstrate scalability to larger freeze dryers, including the determination of vial heat transfer coefficients, K v . Product temperature histories during K v runs were evaluated and compared with those obtained with a commercial laboratory-scale freeze dryer (LyoStar II) for sucrose and mannitol product formulations. When the mini-FD wall temperature was set at the LyoStar II band temperature (- 20°C) to mimic lab dryer edge vials, edge vial drying in the mini-FD possessed an average K v within 5% of those obtained during drying in the LyoStar II. When the wall temperature of the mini-FD was set equal to the central vial product temperature, edge vials behaved as center vials, possessing a K v value within 5% of those measured in the LyoStar II. During both K v runs and complete product freeze drying runs, the temperature-time profiles for the average edge vials and central vial in the mini-FD agreed well with the average edge and average central vials of the LyoStar II.

  2. THE X-RAY PROPERTIES OF THE OPTICALLY BRIGHTEST MINI-BAL QUASARS FROM THE SLOAN DIGITAL SKY SURVEY

    International Nuclear Information System (INIS)

    Wu Jianfeng; Brandt, W. N.; Comins, M. L.; Garmire, Gordon P.; Schneider, Donald P.; Gibson, Robert R.; Shemmer, Ohad

    2010-01-01

    We have compiled a sample of 14 of the optically brightest radio-quiet quasars (m i ≤ 17.5 and z ≥ 1.9) in the Sloan Digital Sky Survey Data Release 5 quasar catalog that have C IV mini-broad absorption lines (mini-BALs) present in their spectra. X-ray data for 12 of the objects were obtained via a Chandra snapshot survey using ACIS-S, while data for the other two quasars were obtained from archival XMM-Newton observations. Joint X-ray spectral analysis shows that the mini-BAL quasars have a similar average power-law photon index (Γ ∼ 1.9) and level of intrinsic absorption (N H ∼ 21 cm -2 ) as non-BMB (neither BAL nor mini-BAL) quasars. Mini-BAL quasars are more similar to non-BMB quasars than to BAL quasars in their distribution of relative X-ray brightness (assessed with Δα ox ). Relative colors indicate mild dust reddening in the optical spectra of mini-BAL quasars. Significant correlations between Δα ox and UV absorption properties are confirmed for a sample of 56 sources combining mini-BAL and BAL quasars with high signal-to-noise ratio rest-frame UV spectra, which generally supports models in which X-ray absorption is important in enabling driving of the UV absorption-line wind. We also propose alternative parameterizations of the UV absorption properties of mini-BAL and BAL quasars, which may better describe the broad absorption troughs in some respects.

  3. Mäo kolmnurka kerkib mini-Eesti / Rein Sikk

    Index Scriptorium Estoniae

    Sikk, Rein, 1961-

    2010-01-01

    Järvamaale Mäo kolmnurka kavandatavast Eestimaad vähendatuna näitavast teemapargist mini-Eesti, mis peaks valmima 2014. aastaks. Kavandatavast Narva vanalinna rekonstruktsioonist maketina, mis peaks tulema umber 200 korda 400 meetri suurune

  4. Mini-grid for sustainable integrated coastal development

    International Nuclear Information System (INIS)

    Bala, B.K.; Islam, M.M.

    2005-01-01

    Power grid cannot reach everywhere. Yet there are alternatives. Renewable energy can offer an ideal source of electricity for the communities far from a grid- on an island, or other isolated situations. Design and economics of a solar-diesel hybrid mini-grid system for 132 families in an isolated island-Sandwip are presented. The electrical load is considered based on the local needs and the electrical load demand is 20 kWh. The sizing of the hybrid system consists of 31 solar modules, 10 number of 24 V batteries, 2 Inverters having a total capacity of 24 kW, 24 V DC/220 V AC. A diesel generator set of 10 kW capacity is selected for back up during shortfall. The life cycle cost (LCC) is estimated and LCC is found to be Tk.15.51 / kWh compared to electricity price of Tk.4.00/kWh. Finally, the sustainability of solar-diesel hybrid mini-grid for an isolated island -Sandwip is discussed. (author)

  5. Effects of Onion Extracts on Growth Performance, Carcass Characteristics and Blood Profiles of White Mini Broilers

    Directory of Open Access Journals (Sweden)

    B. K. An

    2015-02-01

    Full Text Available This experiment was carried out to investigate effects of onion extract on growth performance, meat quality and blood profiles of White mini broilers. Total of 600 one-d-old male White mini broiler chicks were divided into four groups and fed control diets (non-medicated commercial diet or antibiotics medicated or experimental diets (non-medicated diets containing 0.3% or 0.5% onion extract for 5 wks. The final body weight (BW and weight gain of the group fed non-medicated control diet were lower than those of medicated control group (p<0.01. The chicks fed diet with 0.3% or 0.5% onion extract showed a similar BW to that of medicated control group. The relative weight of various organs, such as liver, spleen, bursa of Fabricius, abdominal fat, and the activities of serum enzymes were not affected by dietary treatments. There were no significant differences in meat color among groups. Whereas, groups fed diets containing onion extract had slightly lower cooking loss and higher shear force value, but not significantly. The concentrations of serum free cholesterol and triacylglycerol in groups fed diet containing onion extract were significantly decreased compared with those of controls (p<0.01. In conclusion, the onion extracts exerted a growth-promoting effect when added in White mini broiler diets, reflecting potential alternative substances to replace antibiotics.

  6. New journals

    NARCIS (Netherlands)

    NN,

    1977-01-01

    Brunonia is the title of a journal that will replace the Contributions from Herbarium Australiense (last no. 17, 1976). Subscriptions Aust. $ 4. annual, Herbarium Australiense, P.O. Box 1600, Canberra City, A.C.T. 2601, Australia. Nature Malaysiana, published quarterly by Tropical Press, 64A Jl.

  7. Comparison between McMaster and Mini-FLOTAC methods for the enumeration of Eimeria maxima oocysts in poultry excreta.

    Science.gov (United States)

    Bortoluzzi, C; Paras, K L; Applegate, T J; Verocai, G G

    2018-04-30

    Monitoring Eimeria shedding has become more important due to the recent restrictions to the use of antibiotics within the poultry industry. Therefore, there is a need for the implementation of more precise and accurate quantitative diagnostic techniques. The objective of this study was to compare the precision and accuracy between the Mini-FLOTAC and the McMaster techniques for quantitative diagnosis of Eimeria maxima oocyst in poultry. Twelve pools of excreta samples of broiler chickens experimentally infected with E. maxima were analyzed for the comparison between Mini-FLOTAC and McMaster technique using, the detection limits (dl) of 23 and 25, respectively. Additionally, six excreta samples were used to compare the precision of different dl (5, 10, 23, and 46) using the Mini-FLOTAC technique. For precision comparisons, five technical replicates of each sample (five replicate slides on one excreta slurry) were read for calculating the mean oocyst per gram of excreta (OPG) count, standard deviation (SD), coefficient of variation (CV), and precision of both aforementioned comparisons. To compare accuracy between the methods (McMaster, and Mini-FLOTAC dl 5 and 23), excreta from uninfected chickens was spiked with 100, 500, 1,000, 5,000, or 10,000 OPG; additional samples remained unspiked (negative control). For each spiking level, three samples were read in triplicate, totaling nine reads per spiking level per technique. Data were transformed using log10 to obtain normality and homogeneity of variances. A significant correlation (R = 0.74; p = 0.006) was observed between the mean OPG of the McMaster dl 25 and the Mini-FLOTAC dl 23. Mean OPG, CV, SD, and precision were not statistically different between the McMaster dl 25 and Mini-FLOTAC dl 23. Despite the absence of statistical difference (p > 0.05), Mini-FLOTAC dl 5 showed a numerically lower SD and CV than Mini-FLOTAC dl 23. The Pearson correlation coefficient revealed significant and positive

  8. Mini clinical evaluation exercise in undergraduate dermatovenereology education: an experience of University of Pamukkale, Medical Faculty

    Directory of Open Access Journals (Sweden)

    Şeniz Ergin

    2013-03-01

    Full Text Available Background and Design: Mini Clinical Evaluation Exercise (Mini-CEX is being widely used in medical education and is a reliable and valid method for the assessment of residents’ competency in medical interviewing, physical examination, humanistic qualities/professionalism, clinical judgment, counseling skills, organization, and efficiency. In order to enhance formative evaluation methods in our faculty, we planned to apply the method to students on dermatovenereology training. Materials and Methods: The Mini-CEX was performed by residents to 42 medical students. At first, 5 residents were evaluated by a faculty member with Mini-CEX and were informed about their application-oriented evaluator roles. The students were informed prior to conducting the assessment. Standard Mini-CEX form was used for the assessment. The participants were rated in 7 competencies and each was rated using a 9-point Likert scale. At the end of each encounter, students and evaluators rated their satisfaction with Mini-CEX using a 9-point Likert scale. Student’s t-test and one-way ANOVA were used for statistical analysis. Student feedback was evaluated with “grounded theory”. Results: A total of 50 assessments, 44 in outpatient and 6 in inpatient clinic, were performed. Satisfaction with the Mini-CEX was rated by the evaluators and the students as 7,16 and 7,98, respectively. There was no significant difference between the evaluators in terms of student satisfaction. Average time spent on observing the encounter and in giving feedback was 16.5 and 6.5 minutes, respectively. There was no significant difference between assessors in terms of time spent observing and giving feedback. Average scores of assessed clinical competencies were between 4,28 and 8,14. The highest scores were reported on humanistic qualities/ professionalism whereas the lowest were reported on clinical judgment skills. Discussion: According to our data, we believe that Mini-CEX may be used as an

  9. Measurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy.

    Science.gov (United States)

    Sung, K H; Min, E; Chung, C Y; Jo, B C; Park, M S; Lee, K

    2016-03-01

    This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy. © The Author(s) 2015.

  10. Iranian Version of the Mini-Mental Adjustment to Cancer Scale: Factor Structure and Psychometric Properties.

    Science.gov (United States)

    Patoo, Mozhgan; Allahyari, Abbas Ali; Moradi, Ali Reza; Payandeh, Mehrdad

    2015-01-01

    Mental adjustment to cancer is known as a psychological, physical, and psychological health variable among cancer patients. The present study examines the factor structure and psychometric properties of the Mini-Mental Adjustment to Cancer scale (Mini-MAC) in a sample of Iranian adults who suffer from cancer. The sample consists of 320 cancer patients selected through non-random convenient sampling procedure from the hospitals and clinics in the cities of Kermanshah and Shiraz in Iran, using the Mini-MAC scale. One hundred of these patients also completed the Hospital Anxiety and Depression scale. Statistical methods used to analyze the data included confirmatory and exploratory factor analysis, discriminate validity, and Cronbach alpha coefficients for internal consistency. Factor analysis confirms five factors in the Mini-MAC. The values of fit indices are within the acceptable range. Significant correlations between the Mini-MAC and other measures also show that this scale has discriminate validity. Alpha coefficients for the subscales are Helplessness/Hopelessness,.94; Cognitive Avoidance.76; Anxious Preoccupation,.90; Fatalism,.77; Fighting Spirit.80; and total scale.84, respectively. The results confirm the five-factor structure of the Persian Mini-MAC scale and also prove that it is a reliable and valid scale. They show that this scale has sufficient power to measure different aspects of mental adjustment in patients with cancer.

  11. Evaluation of mechanical strengths of three types of mini-implants in artificial bones

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Tseng

    2017-02-01

    Full Text Available We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm, Type B (stainless steel, 2.0×12 mm, and Type C (titanium alloy, 2.0×11 mm.The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT, resonance frequency (RF, and removal torque (RT] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively. In the 45° test, the RFs of Type C (9.2 kHz was significantly higher than those of Type A (7.0 kHz and Type B (6.7 kHz. The anchor area of the mini-implants was in the order of Type C (706 mm2>Type B (648 mm2>Type A (621 mm2. Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants.

  12. Evaluation of mechanical strengths of three types of mini-implants in artificial bones.

    Science.gov (United States)

    Tseng, Yu-Chuan; Wu, Ju-Hui; Ting, Chun-Chan; Chen, Hong-Sen; Chen, Chun-Ming

    2017-02-01

    We investigates the effect of the anchor area on the mechanical strengths of infrazygomatic mini-implants. Thirty mini-implants were divided into three types based on the material and shape: Type A (titanium alloy, 2.0×12 mm), Type B (stainless steel, 2.0×12 mm), and Type C (titanium alloy, 2.0×11 mm).The mini-implants were inserted at 90° and 45° into the artificial bone to a depth of 7 mm, without predrilling. The mechanical strengths [insertion torque (IT), resonance frequency (RF), and removal torque (RT)] and the anchor area were measured. We hypothesized that no correlation exists among the mechanical forces of each brand. In the 90° tests, the IT, RF, and RT of Type C (8.5 N cm, 10.2 kHz, and 6.1 N cm, respectively) were significantly higher than those of Type A (5.0 N cm, 7.7 kHz, and 4.7 N cm, respectively). In the 45° test, the RFs of Type C (9.2 kHz) was significantly higher than those of Type A (7.0 kHz) and Type B (6.7 kHz). The anchor area of the mini-implants was in the order of Type C (706 mm 2 )>Type B (648 mm 2 )>Type A (621 mm 2 ). Type C exhibited no significant correlation in intragroup comparisons, and the hypothesis was accepted. In the 90° and 45° tests, Type C exhibited the largest anchor area and the highest mechanical strengths (IT, RF, and RT) among the three types of mini-implants. The anchor area plays a crucial role in the mechanical strength of mini-implants. Copyright © 2016. Published by Elsevier Taiwan.

  13. Analisis Sumber dan Penggunaan Modal Kerja pada Mini Market Pelangi Jambi

    OpenAIRE

    Sopini, Pupu; Trifani, Chairani Yuli

    2017-01-01

    The working capital having nature of flexible, big or small working capital can be added or reduced in accordance with need company. Control working capital that will exactly ensure of continuity the operations firm efficien and economical. The objective of analyze sources and use working capital to how working capital used. Research objectives: 1) to know the sources and the use of capital work At Mini Market Pelangi Period 2012-2016. 2) to analyze the use of capital work At Mini Market Pel...

  14. STORAGE TIME EFFECT ON MINI-CUTTINGS ROOTING IN Tectona grandis LINN F. CLONES

    Directory of Open Access Journals (Sweden)

    Yorleny Badilla

    2017-08-01

    Full Text Available ABSTRACT The study aimed to evaluate the influence of storage length on Tectona grandis mini-cuttings survival and rooting. A factorial arrangement (4 x 7 was utilized, based on four clones (Carapá, Ipê, GU5 and TB7 and seven time intervals from mini-cuttings harvesting until final sowing (0, 1, 2, 4, 8, 12 and 16 hours. A randomized block design with three replicates and 16 mini-cuttings per experimental unit was utilized. Survival and rooting rates were evaluated after greenhouse culture (30 days after sowing and after shadow house culture (40 days after sowing; as well as height, collar diameter, aerial and root biomass 55 days after sowing. No significant differences were observed in survival and rooting rates among time intervals in teak mini-cuttings preparation from these four clones. However differences among clones were registered for rooting rate, suggesting a genotypic effect. Survival and rooting rates were very high after greenhouse culture (93% and 90% respectively, as well as survival after culture in a shadow-house (88%.

  15. Mini Project Programming Exams

    DEFF Research Database (Denmark)

    Nørmark, Kurt; Thomsen, Lone Leth; Torp, Kristian

    2008-01-01

    A number of different types of final programming exams used or considered at the Department of Computer Science, Aalborg University, are identified and analyzed. Based on this analysis, a new type of programming exam is introduced called a Mini Project Programming (MIP) exam. MIP is a group...... years. The MIP exam is a compromise between (1) a long problem-based project exam and (2) a short oral or written programming exam. It is concluded that the strengths of MIP are the high degree of realism in the exam assignment and comprehensiveness relative to the course syllabus. The main challenge...

  16. International Journal of Humanistic Studies: Journal Sponsorship

    African Journals Online (AJOL)

    International Journal of Humanistic Studies: Journal Sponsorship. Journal Home > About the Journal > International Journal of Humanistic Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  17. East African Journal of Statistics: Journal Sponsorship

    African Journals Online (AJOL)

    East African Journal of Statistics: Journal Sponsorship. Journal Home > About the Journal > East African Journal of Statistics: Journal Sponsorship. Log in or Register to get access to full text downloads.

  18. African Journal of Neurological Sciences: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Neurological Sciences: Journal Sponsorship. Journal Home > About the Journal > African Journal of Neurological Sciences: Journal Sponsorship. Log in or Register to get access to full text downloads.

  19. Nigerian Journal of General Practice: Journal Sponsorship

    African Journals Online (AJOL)

    Nigerian Journal of General Practice: Journal Sponsorship. Journal Home > About the Journal > Nigerian Journal of General Practice: Journal Sponsorship. Log in or Register to get access to full text downloads.

  20. African Journal of Political Science: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Political Science: Journal Sponsorship. Journal Home > About the Journal > African Journal of Political Science: Journal Sponsorship. Log in or Register to get access to full text downloads.

  1. African Journal of AIDS Research: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of AIDS Research: Journal Sponsorship. Journal Home > About the Journal > African Journal of AIDS Research: Journal Sponsorship. Log in or Register to get access to full text downloads.

  2. African Journal of Management Research: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Management Research: Journal Sponsorship. Journal Home > About the Journal > African Journal of Management Research: Journal Sponsorship. Log in or Register to get access to full text downloads.

  3. African Journal of Infectious Diseases: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Infectious Diseases: Journal Sponsorship. Journal Home > About the Journal > African Journal of Infectious Diseases: Journal Sponsorship. Log in or Register to get access to full text downloads.

  4. West African Journal of Radiology: Journal Sponsorship

    African Journals Online (AJOL)

    West African Journal of Radiology: Journal Sponsorship. Journal Home > About the Journal > West African Journal of Radiology: Journal Sponsorship. Log in or Register to get access to full text downloads.

  5. Journal of Civil Engineering, JKUAT: Journal Sponsorship

    African Journals Online (AJOL)

    Journal of Civil Engineering, JKUAT: Journal Sponsorship. Journal Home > About the Journal > Journal of Civil Engineering, JKUAT: Journal Sponsorship. Log in or Register to get access to full text downloads.

  6. New Egyptian Journal of Microbiology: Journal Sponsorship

    African Journals Online (AJOL)

    New Egyptian Journal of Microbiology: Journal Sponsorship. Journal Home > About the Journal > New Egyptian Journal of Microbiology: Journal Sponsorship. Log in or Register to get access to full text downloads.

  7. Mgbakoigba: Journal of African Studies: Journal Sponsorship

    African Journals Online (AJOL)

    Mgbakoigba: Journal of African Studies: Journal Sponsorship. Journal Home > About the Journal > Mgbakoigba: Journal of African Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  8. Design of the MiniSLAR system for Bruce A

    International Nuclear Information System (INIS)

    Gray, M.G.

    1995-01-01

    Cancellation of Bruce A Retube created the need to perform SLAR on Unit 1. The existing SLAR system cannot reach Unit 1 and alternative systems had limitations. The concept and design of MiniSLAR were driven by the availability of existing components made for Retube. The MiniSLAR concept was developed by a team with members representing operators, technicians, and designers from various departments within Ontario Hydro and GE Canada. Overall project leadership was provided by Bruce A Projects and Modifications Department with assistance from Ontario Hydro Nuclear Technology Services. The responsibility for detailed design was assigned by Ontario Hydro to GE Canada. The detailed design proceeded with continual input and review by the team. The MiniSLAR delivery machine consists of a closure removal ram, a shield plug removal ram and a SLAR tool delivery ram attached to the sliding plate of a horizontal indexing mechanism. The moving plate is constrained by guide rails to a fixed plate and seals against it with o-rings. A snout and clamping mechanism mounts on the front of the fixed plate. The machine mounts atop a work table which provides the various motions required for endfitting engagement. Some operations are performed manually while others are remote and automatic. (author)

  9. Nigerian Journal of Gastroenterology and Hepatology: Journal ...

    African Journals Online (AJOL)

    Nigerian Journal of Gastroenterology and Hepatology: Journal Sponsorship. Journal Home > About the Journal > Nigerian Journal of Gastroenterology and Hepatology: Journal Sponsorship. Log in or Register to get access to full text downloads.

  10. Mini-column assay for rapid detection of malachite green in fish.

    Science.gov (United States)

    Shalaby, Ali R; Emam, Wafaa H; Anwar, Mervat M

    2017-07-01

    A simple, rapid and economical mini-column method for detecting malachite green (MG) residue in fish was developed. The method used a column with 2mm ID that was tightly packed with silica gel followed by alumina. Detection of MG was performed by viewing the developed mini-column at visible light by naked eye; where MG was seen as compact green band at the confluence of the silica gel layer with alumina layer. The limit of detection of the assay was 2ng which conform the minimum required performance limit (MRPL). Evaluation utility of the method indicated that all blank and spiked samples at levels below MRPL were assessed as accepted. The intensity of the green band increased whenever MG level in the extract increased; indicated that suggested mini-column technique could be used for semi-quantitative determination of MG in fish samples. The method can be used to select the questionable samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Mini-batch optimized full waveform inversion with geological constrained gradient filtering

    Science.gov (United States)

    Yang, Hui; Jia, Junxiong; Wu, Bangyu; Gao, Jinghuai

    2018-05-01

    High computation cost and generating solutions without geological sense have hindered the wide application of Full Waveform Inversion (FWI). Source encoding technique is a way to dramatically reduce the cost of FWI but subject to fix-spread acquisition setup requirement and slow convergence for the suppression of cross-talk. Traditionally, gradient regularization or preconditioning is applied to mitigate the ill-posedness. An isotropic smoothing filter applied on gradients generally gives non-geological inversion results, and could also introduce artifacts. In this work, we propose to address both the efficiency and ill-posedness of FWI by a geological constrained mini-batch gradient optimization method. The mini-batch gradient descent optimization is adopted to reduce the computation time by choosing a subset of entire shots for each iteration. By jointly applying the structure-oriented smoothing to the mini-batch gradient, the inversion converges faster and gives results with more geological meaning. Stylized Marmousi model is used to show the performance of the proposed method on realistic synthetic model.

  12. A simple and versatile mini-arc plasma source for nanocrystal synthesis

    International Nuclear Information System (INIS)

    Chen Junhong; Lu Ganhua; Zhu Liying; Flagan, Richard C.

    2007-01-01

    Nanocrystals in the lower-nanometer-size range are attracting growing interest due to their unique properties. A simple and versatile atmospheric direct current mini-arc plasma source has been developed to produce nanoparticles as small as a few nanometers. The nanoparticles are formed by direct vaporization of solid precursors followed by a rapid quenching. Both semiconductor tin oxide and metallic silver nanoparticles have been produced at rates of 1-10 mg/h using the mini-arc source. Transmission electron microscopy and X-ray diffraction analyses indicate that most nanoparticles as produced are nonagglomerated and crystalline. Size distributions of nanoparticles measured with an online scanning electrical mobility spectrometer are broader than the self-preserving distribution, suggesting that the nanoparticle growth is coagulation-dominated, and that the particles experience a range of residence times. The electrical charges carried by as-produced aerosol nanoparticles facilitate the manipulation of nanoparticles. The new mini-arc plasma source hence shows promise to accelerate the exploration of nanostructured materials

  13. Mini-laparotomic Colpotomy for a Cervicovaginal Leiomyoma: Preservation of hymenal integrity

    Directory of Open Access Journals (Sweden)

    Ibrahim Yalçin

    2016-03-01

    Full Text Available Background: Leiomyomas are the most common benign tumors of the uterus. Removal of the prolapsed pedunculated submucous myoma represents a distinct entity. Evaluation and treatment of such cases may need intervention via the hymen.Mini-laparotomic management of a pedunculated submucous myoma while preserving hymen integrity in a virginal patient is described as a safe alternative.. Case: A 30-year old, nulliparous virgin woman admitted to the outpatient- clinic with the complaint of irregular menstrual bleeding ongoing for three months. Pelvic ultrasound revealed a 5×6 cm solid mass in the cervico-vaginal location that filled the vaginal margins. Due to the patient’s consistent desire for preserving hymenal integrity, mini-laparotomic colpotomy was performed and the mass was removed successfully. Conclusion: Mini-laparotomic colpotomy, preserving hymen integrity, provides excellent visualization and it is a convenient and effective tool in the management of a cervicovaginal pedunculated submucous myoma

  14. Coherence between institutions and technologies - The case of mini hydropower in Switzerland

    OpenAIRE

    Crettenand, Nicolas

    2009-01-01

    Switzerland, with the forecasted electricity gap between domestic production and demand, aims to significantly increase renewable energy sources including hydropower. Mini hydropower (below 1MW) currently has considerable unused technical potential. As a renewable energy source (RES) it can contribute to climate change mitigation. CO2-taxes or emission trading systems (ETS) for planned thermal power plants could help facilitate mini hydropower (MHP). The technology is mature, but requires ade...

  15. An investigation of customer satisfaction and loyalty in projects of mini-hotels

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2015-01-01

    The hospitality industry continues to evolve and improve in terms of Ukrainian realities of political and economic instability; managers of mini-hotels are experiencing difficulties with the implementation of repeat sales, increasing the number of loyal customers and the preservation of loyal customers, maintaining a high level of consumer loyalty and customer satisfaction.The article reveals the concept of satisfaction and loyalty of mini-hotels customers. It is schematically represented the...

  16. 'Mini'-Roadmapping - Ensuring Timely Sites' Cleanup/Closure by Resolving Science and Technology Issues

    International Nuclear Information System (INIS)

    Luke, D.E.; Dixon, B.W.; Murphy, J.A.

    2003-01-01

    Roadmapping is a powerful tool to manage technical risks and opportunities associated with complex problems. Roadmapping identifies technical capabilities required for both project- and program-level efforts and provides the basis for plans that ensure the necessary enabling activities will be done when needed. Roadmapping reveals where to focus further development of the path forward by evaluating uncertainties for levels of complexity, impacts, and/or the potential for large payback. Roadmaps can be customized to the application, a ''graded approach'' if you will. Some roadmaps are less detailed. We have called these less detailed, top-level roadmaps ''mini-roadmaps''. These mini roadmaps are created to tie the needed enablers (e.g., technologies, decisions, etc.) to the functions. If it is found during the mini-roadmapping that areas of significant risk exist, then those can be roadmapped further to a lower level of detail. Otherwise, the mini-roadmap may be sufficient to manage the project/program risk. Applying a graded approach to the roadmapping can help keep the costs down. Experience has indicated that it is best to do mini-roadmapping first and then evaluate the risky areas to determine whether to further evaluate those areas. Roadmapping can be especially useful for programs/projects that have participants from multiple sites, programs, or other entities which are involved. Increased synergy, better communications, and increased cooperation are the results from roadmapping a program/project with these conditions

  17. Development of mini VSAT system

    Science.gov (United States)

    Lu, Shyue-Ching; Chiu, Wu-Jhy; Lin, Hen-Dao; Shih, Mu-Piao

    1992-03-01

    This paper presents the mini VSAT (very small aperture terminal) system, which is a low cost networking system providing economical alternatives to the business world's datacom needs. The system is designed to achieve the highest possible performance/price ratio for private VSAT networks that range from a few tens of remote terminals to large networks of several thousands remote terminals. The paper describes the system architecture, major features, hardware and software structure, access protocol and performance of the developed system.

  18. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    Science.gov (United States)

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  19. Elaboration of mini plates with U-Mo for irradiation in a high flux reactor

    International Nuclear Information System (INIS)

    Pasqualini, Enrique E.

    2005-01-01

    Full text: International new efforts for the reconversion of HEU in research, testing and radioisotopes production reactors, have greatly incremented U-Mo fuels qualification activities. These qualifications require the resolution of undesired interaction at high fluxes between UMo particles and the aluminum matrix in the case of dispersed fuels and the development of U-Mo monolithic fuels. These efforts are being manifested in the planning and execution of additional series of irradiation tests of mini plates and full size plates. Recently, CNEA has elaborated mini plates with different proposals for the irradiation at the ATR reactor (250 MWTH, maximum thermal neutron flux 10 15 n.cm -2 .seg -1 ) at Idaho National Laboratory, USA. Uranium 7% (w/w) molybdenum (U-7Mo) particles were coated with silicon. Chemical vapour deposition (CVD) of silane and high temperature diffusion of silicon were used. Hydrided, milled and dehydrated (HMD) particles heat treated at 1000 C degrees during four hours and centrifugal atomized powder were coated and the results compared. Mini plates were elaborated with both kinds of particles. Mini plates were also elaborated with U-7Mo and silicon particles dispersed in the aluminium matrix. Monolithic mini plates were also developed by co lamination of U-7Mo with a Zircaloy-4 cladding. The different steps of this process are detailed and the method is shown to be versatile, can be easily scaled up and is performed with small modifications of usual equipment in fuel plants. The irradiation experiment is called RERTR-7A, includes a total of 32 mini plates and it is planed to finalize by mid 2006. (author) [es

  20. Long-term efficacy of a mini-course in radiation-reducing techniques in invasive cardiology

    International Nuclear Information System (INIS)

    Kuon, E.; Empen, K.; Hummel, A.; Doerr, M.; Reffelmann, T.; Felix, S.B.; Weitmann, K.; Hoffmann, W.; Staudt, A.

    2013-01-01

    Purpose: To validate the long-term efficacy of a 90-min. educational mini-course in less-irradiating cardiac interventional techniques. Materials and Methods: Before, two months after, and two years after the mini-course (periods I, II, and III), we analyzed the following radiation dose parameters for ten coronary angiographies (CA), performed by each of 7 cardiologists: total dose-area product (DAP), radiographic and fluoroscopic DAP fractions, number of radiographic frames and runs, and fluoroscopy time. Results: The median patient DAP for periods I, II and III was 31.4, 15.8 and 8.5 Gy x cm 2 , respectively. The long-term effect was related to shorter median fluoroscopy times (180, 172, and 120 s), shorter (57, 52, and 45) and fewer (12, 12, and 10) radiographic runs, consistent collimation and restriction to an adequate image quality. Both radiographic DAP/frame (28.7, 17.0, and 18.4 mGy x cm 2 ) and fluoroscopic DAP/second (45.7, 24.2, and 10.0 mGy x cm 2 ) decreased significantly. The multivariate linear regression analysis confirmed the increasing efficacy of the mini-course itself (-44.6 and -60.7 %), and revealed a decreasing influence of the interventionalist's experience (-8.6 % and -4.9 % per 1,000 CAs, lifelong performed until the mini-course). The number of CAs performed after the mini-course did not influence the long-term DAP results. Conclusion: The presented educational mini-course allows a significant, long-lasting, and apparently ongoing reduction of patient radiation exposure due to CA. A self-surveillant documentation of relevant radiation parameters is well suited to monitor and improve each operator's individual long-term radiation-reducing efforts. (orig.)

  1. Preliminary study on weapon grade uranium utilization in molten salt reactor miniFUJI

    International Nuclear Information System (INIS)

    Aji, Indarta Kuncoro; Waris, A.

    2014-01-01

    Preliminary study on weapon grade uranium utilization in 25MWth and 50MWth of miniFUJI MSR (molten salt reactor) has been carried out. In this study, a very high enriched uranium that we called weapon grade uranium has been employed in UF 4 composition. The 235 U enrichment is 90 - 95 %. The results show that the 25MWth miniFUJI MSR can get its criticality condition for 1.56 %, 1.76%, and 1.96% of UF 4 with 235 U enrichment of at least 93%, 90%, and 90%, respectively. In contrast, the 50 MWth miniFUJI reactor can be critical for 1.96% of UF 4 with 235 U enrichment of at smallest amount 95%. The neutron spectra are almost similar for each power output

  2. ANALISIS KEMUNCULAN KETERAMPILAN SPESIFIK LAB MIKROBIOLOGI MELALUI PEMBELAJARAN MIKROBIOLOGI BERBASIS PROYEK INKUIRI “MINI-RISET” MAHASISWA BIOLOGI

    Directory of Open Access Journals (Sweden)

    Mr Kusnadi

    2012-01-01

    Full Text Available Telah dilakukan penelitian untuk menganalisis kemunculan keterampilan laboratorium mikrobiologi melalui program pembelajaran mikrobiologi berbasis proyek inkuiri (P2MBPI mini-riset. Penelitian melibatkan sejumlah mahasiswa semester IV Program Studi Biologi di salah satu LPTK Negeri di kota Bandung (n=33, yang mengikuti perkuliahan mikrobiologi. Program pembelajaran dirancang dalam setting laboratorium berbasis proyek inkuiri kelompok (free inquiry labs. Data penelitian dijaring melalui laporan mini-riset, presentasi oral dan poster serta wawancara.  Hasil penelitian  menunjukkan bahwa P2MBPI mini-riset setiap kelompok memberikan kontribusi terhadap kemunculan keterampilan laboratorium mikrobiologi yang cukup beragam. Hal ini selaras dengan tahapan proyek mulai dari pemilihan masalah dan topik mini-riset, sampai pengambilan keputusan proyek yang dilaksanakan oleh kelompok. Secara umum ruang lingkup topik proyek mini-riset mencakup empat bidang, yaitu mikrobiologi pertanian (tanah, mikrobiologi lingkungan (air, mikrobiologi kesehatan, dan mikrobiologi pangan. Hasil analisis kemunculan jenis keterampilan spesifik lab mikrobiologi dari laporan, presentasi oral, dan poster, serta wawancara menunjukkan bahwa sebagian besar kelompok menunjukkan persentase kemunculan jenis keterampilan yang tinggi (100%, yaitu pada keterampilan bekerja aseptik, keterampilan mengisolasi mikroba, sterilisasi, dan menggunakan mikroskop.  Kemunculan jenis keterampilan dengan persentase sedang (75% pada keterampilan identifikasi dan kultivasi mikroorganisme. Selanjutnya berdasarkan hasil wawancara mendalam pada 7 orang mahasiswa, menyatakan bahwa program pembelajaran mikrobiologi berbasis proyek inkuiri mini-riset ini juga sangat berarti, disamping mendapatkan keterampilan lab mikrobiologi, juga dapat membekali keterampilan meneliti (research skill mahasiswa biologi.  Dengan demikian P2MBPI mini-riset ini, perlu terus dikembangkan karena memberikan konstribusi yang

  3. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    Science.gov (United States)

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic. PMID:27901227

  4. The Experiment Production And Examination Of The U3Si2-AI Mini plates For Irradiation Test

    International Nuclear Information System (INIS)

    Supardjo; Boybul; Yowono; Susworo; Permana, S.

    1998-01-01

    The fuel plates containing U 3 Si 2 -AI dispersion fuel having respective loading of 3.55; 4.20; and 4.80 g/cm 3 were prepared by dispersing certain amount of U 3 Si 2 powder in the AI powder as matrix. The weight ratio of U 3 Si 2 and AI at different loading was chosen based on the 19.23 cm 3 volume basis fuel core calculation. Each fuel mixture was pressed into a fuel core having dimension of 100.20 x 60.35 x 3.15 +- (0.05) mm, which was then cut into mini fuel core having dimension of 16 x 8 x 3.15 +- (0.05) mm. The mini plates were prepared by picture and frame technique using AIMg2 as cladding material. The mini plates have been tested for blister, homogeneity, white spots, surface defects and their cladding thickness, revealing that out of 74 mini plates, they are ten (10) mini plates that have to be rejected due to blisters and white spots, thus of 64 mini plates can be further fabricated as samples for irradiation test

  5. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  6. Development of X-ray mini-probes for the Digiray RGX system

    International Nuclear Information System (INIS)

    Wojcik, R.; Kross, B.; Majewski, L.; Majewski, S.; Weisenberger, A.G.; Zorn, C.; Birt, E.A.; Parker, F.R.; Winfree, W.P.; Albert, R.D.; Albert, T.M.

    1994-01-01

    We have developed and tested a variety of X-ray mini-probes for the Reverse Geometry X-radiography trademark ,1 (RGX) system each having their own advantages and disadvantages. These mini-probes consist of small scintillators (as small as 2 mm in diameter and 5 mm long) attached to optical light guides (as long as 14 m) coupled to photomultipliers. Images produced with these probes show that even smaller probes and/or longer light guides may be fashioned. Such probes may be useful in both non-destructive evaluation and medical imaging. ((orig.))

  7. The performance of the Mini-Cog in a sample of low educational level elderly.

    Science.gov (United States)

    Ribeiro Filho, Sergio Telles; Lourenço, Roberto Alves

    2009-01-01

    To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8 th to July 15 th , 2002. All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE) and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R). They were classified as demented or non-demented (DSM-IV). A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  8. Tissue interfaces dosimetry in small field radiotherapy with alanine/EPR mini dosimeters and Monte Carlo-Penelope simulation

    Energy Technology Data Exchange (ETDEWEB)

    Vega R, J. L.; Nicolucci, P.; Baffa, O. [Universidade de Sao Paulo, FFCLRP, Departamento de Fisica, Av. Bandeirantes 3900, Bairro Monte Alegre, 14040-901 Ribeirao Preto, Sao Paulo (Brazil); Chen, F. [Universidade Federale do ABC, CCNH, Rua Santa Adelia 166, Bangu, 09210-170 Santo Andre, Sao Paulo (Brazil); Apaza V, D. G., E-mail: josevegaramirez@yahoo.es [Universidad Nacional de San Agustin de Arequipa, Departamento de Fisica, Arequipa (Peru)

    2014-08-15

    The dosimetry system based on alanine mini dosimeters plus K-Band EPR spectrometer was tested in the tissue-interface dosimetry through the percentage depth-dose (Pdd) determination for 3 x 3 cm{sup 2} and 1 x 1 cm{sup 2} radiation fields sizes. The alanine mini dosimeters were produced by mechanical pressure from a mixture of 95% L-alanine and 5% polyvinyl alcohol (Pva) acting as binder. Nominal dimensions of these mini dosimeters were 1 mm diameter and 3 mm length as well as 3 - 4 mg mass. The EPR spectra of the mini dosimeters were registered using a K-Band (24 GHz) EPR spectrometer. The mini dosimeters were placed in a nonhomogeneous phantom and irradiated with 20 Gy in a 6 MV PRIMUS Siemens linear accelerator, with a source-to-surface distance of 100 cm using the small fields previously mentioned. The cylindrical non-homogeneous phantom was comprised of several disk-shaped plates of different materials in the sequence acrylic-bone cork-bone-acrylic, with dimensions 15 cm diameter and 1 cm thick. The plates were placed in descending order, starting from top with four acrylic plates followed by two bone plates plus eight cork plates plus two bone plates and finally, four acrylic plates (4-2-8-2-4). Pdd curves from the treatment planning system and from Monte Carlo simulation with Penelope code were determined. Mini dosimeters Pdd results show good agreement with Penelope, better than 95% for the cork homogeneous region and 97.7% in the bone heterogeneous region. In the first interface region, between acrylic and bone, it can see a dose increment of 0.6% for mini dosimeters compared to Penelope. At the second interface, between bone and cork, there is 9.1% of dose increment for mini dosimeter relative to Penelope. For the third (cork-bone) and fourth (bone-acrylic) interfaces, the dose increment for mini dosimeters compared to Penelope was 4.1% both. (Author)

  9. Tissue interfaces dosimetry in small field radiotherapy with alanine/EPR mini dosimeters and Monte Carlo-Penelope simulation

    International Nuclear Information System (INIS)

    Vega R, J. L.; Nicolucci, P.; Baffa, O.; Chen, F.; Apaza V, D. G.

    2014-08-01

    The dosimetry system based on alanine mini dosimeters plus K-Band EPR spectrometer was tested in the tissue-interface dosimetry through the percentage depth-dose (Pdd) determination for 3 x 3 cm 2 and 1 x 1 cm 2 radiation fields sizes. The alanine mini dosimeters were produced by mechanical pressure from a mixture of 95% L-alanine and 5% polyvinyl alcohol (Pva) acting as binder. Nominal dimensions of these mini dosimeters were 1 mm diameter and 3 mm length as well as 3 - 4 mg mass. The EPR spectra of the mini dosimeters were registered using a K-Band (24 GHz) EPR spectrometer. The mini dosimeters were placed in a nonhomogeneous phantom and irradiated with 20 Gy in a 6 MV PRIMUS Siemens linear accelerator, with a source-to-surface distance of 100 cm using the small fields previously mentioned. The cylindrical non-homogeneous phantom was comprised of several disk-shaped plates of different materials in the sequence acrylic-bone cork-bone-acrylic, with dimensions 15 cm diameter and 1 cm thick. The plates were placed in descending order, starting from top with four acrylic plates followed by two bone plates plus eight cork plates plus two bone plates and finally, four acrylic plates (4-2-8-2-4). Pdd curves from the treatment planning system and from Monte Carlo simulation with Penelope code were determined. Mini dosimeters Pdd results show good agreement with Penelope, better than 95% for the cork homogeneous region and 97.7% in the bone heterogeneous region. In the first interface region, between acrylic and bone, it can see a dose increment of 0.6% for mini dosimeters compared to Penelope. At the second interface, between bone and cork, there is 9.1% of dose increment for mini dosimeter relative to Penelope. For the third (cork-bone) and fourth (bone-acrylic) interfaces, the dose increment for mini dosimeters compared to Penelope was 4.1% both. (Author)

  10. Mini-Enterprise Projects: Friendship, Business and Learning

    Science.gov (United States)

    Riese, Hanne

    2013-01-01

    This article discusses how the mini-enterprise (ME) approach (Young Enterprise) can be understood as a tool for helping to achieve policy goals set for entrepreneurship. Analysis of 12 semi-structured interviews with 17-year-old students shows how social capital from friendship relations constitutes norms for interaction in MEs. To some extent,…

  11. INTRODUCING A LOW-COST MINI-UAV FOR THERMAL- AND MULTISPECTRAL-IMAGING

    Directory of Open Access Journals (Sweden)

    J. Bendig

    2012-07-01

    Full Text Available The trend to minimize electronic devices also accounts for Unmanned Airborne Vehicles (UAVs as well as for sensor technologies and imaging devices. Consequently, it is not surprising that UAVs are already part of our daily life and the current pace of development will increase civil applications. A well known and already wide spread example is the so called flying video game based on Parrot's AR.Drone which is remotely controlled by an iPod, iPhone, or iPad (http://ardrone.parrot.com. The latter can be considered as a low-weight and low-cost Mini-UAV. In this contribution a Mini-UAV is considered to weigh less than 5 kg and is being able to carry 0.2 kg to 1.5 kg of sensor payload. While up to now Mini-UAVs like Parrot's AR.Drone are mainly equipped with RGB cameras for videotaping or imaging, the development of such carriage systems clearly also goes to multi-sensor platforms like the ones introduced for larger UAVs (5 to 20 kg by Jaakkolla et al. (2010 for forestry applications or by Berni et al. (2009 for agricultural applications. The problem when designing a Mini-UAV for multi-sensor imaging is the limitation of payload of up to 1.5 kg and a total weight of the whole system below 5 kg. Consequently, the Mini-UAV without sensors but including navigation system and GPS sensors must weigh less than 3.5 kg. A Mini-UAV system with these characteristics is HiSystems' MK-Okto (www.mikrokopter.de. Total weight including battery without sensors is less than 2.5 kg. Payload of a MK-Okto is approx. 1 kg and maximum speed is around 30 km/h. The MK-Okto can be operated up to a wind speed of less than 19 km/h which corresponds to Beaufort scale number 3 for wind speed. In our study, the MK-Okto is equipped with a handheld low-weight NEC F30IS thermal imaging system. The F30IS which was developed for veterinary applications, covers 8 to 13 μm, weighs only 300 g, and is capturing the temperature range between −20 °C and 100 °C. Flying at a height of

  12. [White House Conference on Aging, 1981: Reports of the Mini-Conferences, MCR 1-42.

    Science.gov (United States)

    White House Conference on Aging, Washington, DC.

    This document contains the 42 reports from mini-conferences held in various nationwide locations prior to the 1981 White House Conference on Aging. Each report presents an overview of the topic, descriptions of particular problems, and statements of recommendations, based on the views of mini-conference participants, and made available to the…

  13. Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Marczak, Alana; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2017-09-15

    The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: 360° and 180° cone-beam computed tomography (CBCT) acquisition protocols. A small-volume 180° CBCT scan and a 360° CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up 360° CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intra-rater agreement. In this ex vivo study, we found that the 180° rotational acquisition was as effective as the conventional 360° rotational acquisition for the preoperative evaluation of potential mini-implant sites.

  14. Support for designing waste sorting systems: A mini review.

    Science.gov (United States)

    Rousta, Kamran; Ordoñez, Isabel; Bolton, Kim; Dahlén, Lisa

    2017-11-01

    This article presents a mini review of research aimed at understanding material recovery from municipal solid waste. It focuses on two areas, waste sorting behaviour and collection systems, so that research on the link between these areas could be identified and evaluated. The main results presented and the methods used in the articles are categorised and appraised. The mini review reveals that most of the work that offered design guidelines for waste management systems was based on optimising technical aspects only. In contrast, most of the work that focused on user involvement did not consider developing the technical aspects of the system, but was limited to studies of user behaviour. The only clear consensus among the articles that link user involvement with the technical system is that convenient waste collection infrastructure is crucial for supporting source separation. This mini review reveals that even though the connection between sorting behaviour and technical infrastructure has been explored and described in some articles, there is still a gap when using this knowledge to design waste sorting systems. Future research in this field would benefit from being multidisciplinary and from using complementary methods, so that holistic solutions for material recirculation can be identified. It would be beneficial to actively involve users when developing sorting infrastructures, to be sure to provide a waste management system that will be properly used by them.

  15. Energy-Water Nexus Relevant to Baseload Electricity Source Including Mini/Micro Hydropower Generation

    Science.gov (United States)

    Fujii, M.; Tanabe, S.; Yamada, M.

    2014-12-01

    Water, food and energy is three sacred treasures that are necessary for human beings. However, recent factors such as population growth and rapid increase in energy consumption have generated conflicting cases between water and energy. For example, there exist conflicts caused by enhanced energy use, such as between hydropower generation and riverine ecosystems and service water, between shale gas and ground water, between geothermal and hot spring water. This study aims to provide quantitative guidelines necessary for capacity building among various stakeholders to minimize water-energy conflicts in enhancing energy use. Among various kinds of renewable energy sources, we target baseload sources, especially focusing on renewable energy of which installation is required socially not only to reduce CO2 and other greenhouse gas emissions but to stimulate local economy. Such renewable energy sources include micro/mini hydropower and geothermal. Three municipalities in Japan, Beppu City, Obama City and Otsuchi Town are selected as primary sites of this study. Based on the calculated potential supply and demand of micro/mini hydropower generation in Beppu City, for example, we estimate the electricity of tens through hundreds of households is covered by installing new micro/mini hydropower generation plants along each river. However, the result is based on the existing infrastructures such as roads and electric lines. This means that more potentials are expected if the local society chooses options that enhance the infrastructures to increase micro/mini hydropower generation plants. In addition, further capacity building in the local society is necessary. In Japan, for example, regulations by the river law and irrigation right restrict new entry by actors to the river. Possible influences to riverine ecosystems in installing new micro/mini hydropower generation plants should also be well taken into account. Deregulation of the existing laws relevant to rivers and

  16. Genotype by Environment Effects on Potato Mini-Tuber Seed Production in an Aeroponics System

    Directory of Open Access Journals (Sweden)

    Julián F. Mateus-Rodriguez

    2014-11-01

    Full Text Available In order to evaluate the environmental effect on plant development and mini-tuber production of a diverse group of potato genotypes grown under an aeroponic system, a G × E interaction experiment was carried out in greenhouses located at CIP’s experimental stations in La Molina (Lima and Huancayo (Junín. Five contrasting environments were set-up and evaluated. A combined Analysis of Variance was performed for the variables “days to tuber set”, “days to senescence” and “plant height”. An Additive Main Effects and Multiplicative Interaction (AMMI Analysis was performed for yield variables: mini-tuber “weight” and “number of mini-tubers” per plant. There was a high variation in all the responses to the treatments. “Days to tuber set” was influenced by genetic responses, temperature and greenhouse Photosynthetically Active Radiation intensity. Considerable increases in the length of the vegetative cycle and plant height were recorded for all genotypes, and these were particularly notable in the warmer coastal environments. AMMI analysis showed that yield variables were primarily influenced by the genotypic effect followed by the genotype by environment interaction effect. The Venturana variety (T2 was the best performing genotype with a total average mini-tuber “weight” of 644 g per plant while the Chucmarina variety (T1 performed best for the variable “number of mini-tubers” with an overall average of 60.2 mini-tubers per plant. Both showed stability across different environments for these variables. The advanced clones T3 (395434.1, T5 (397077.16 and T6 (397073.16 showed stability for yield variables, but their performance was below the overall average of the trial. It is recommended that the environment and management should ideally be tailored to the genotype as this will result in significant yield gains.

  17. Long-term efficacy of a mini-course in radiation-reducing techniques in invasive cardiology

    Energy Technology Data Exchange (ETDEWEB)

    Kuon, E. [Klinik Fraenkische Schweiz, Ebermannstadt (Germany). Abt. fuer Kardiologie; Empen, K.; Hummel, A.; Doerr, M.; Reffelmann, T.; Felix, S.B. [Ernst-Moritz-Arndt-Universitaet, Greifswald (Germany). Abt. fuer Innere Medizin B; Weitmann, K.; Hoffmann, W. [Ernst-Moritz-Arndt-Universitaet, Greifswald (Germany). Inst. fuer Versorgungsmedizin; Staudt, A. [Helios Kliniken, Schwerin (Germany). Abt. fuer Kardiologie und Angiologie

    2013-08-15

    Purpose: To validate the long-term efficacy of a 90-min. educational mini-course in less-irradiating cardiac interventional techniques. Materials and Methods: Before, two months after, and two years after the mini-course (periods I, II, and III), we analyzed the following radiation dose parameters for ten coronary angiographies (CA), performed by each of 7 cardiologists: total dose-area product (DAP), radiographic and fluoroscopic DAP fractions, number of radiographic frames and runs, and fluoroscopy time. Results: The median patient DAP for periods I, II and III was 31.4, 15.8 and 8.5 Gy x cm{sup 2}, respectively. The long-term effect was related to shorter median fluoroscopy times (180, 172, and 120 s), shorter (57, 52, and 45) and fewer (12, 12, and 10) radiographic runs, consistent collimation and restriction to an adequate image quality. Both radiographic DAP/frame (28.7, 17.0, and 18.4 mGy x cm{sup 2}) and fluoroscopic DAP/second (45.7, 24.2, and 10.0 mGy x cm{sup 2}) decreased significantly. The multivariate linear regression analysis confirmed the increasing efficacy of the mini-course itself (-44.6 and -60.7 %), and revealed a decreasing influence of the interventionalist's experience (-8.6 % and -4.9 % per 1,000 CAs, lifelong performed until the mini-course). The number of CAs performed after the mini-course did not influence the long-term DAP results. Conclusion: The presented educational mini-course allows a significant, long-lasting, and apparently ongoing reduction of patient radiation exposure due to CA. A self-surveillant documentation of relevant radiation parameters is well suited to monitor and improve each operator's individual long-term radiation-reducing efforts. (orig.)

  18. A STUDY ON MANAGEMENT OF CHRONIC SUBDURAL HAEMATOMA- BURR HOLE EVACUATION AND MINI CRANIOTOMY

    Directory of Open Access Journals (Sweden)

    Nandigama Pratap Kumar

    2016-11-01

    Full Text Available BACKGROUND Chronic SDH is one of the common neurosurgical conditions requiring surgical treatment. The incidence of chronic SDH is 1.7- 18 per 1,00,000 population. The incidence is higher in the elderly patients, i.e. 58 per 1,00,000. Various treatment modalities available for the treatment of chronic SDH indicate that there is no gold standard for the treatment of chronic SDH. Recurrence is the major problem following treatment and can be as high as 30%. Mini craniotomy is one of the surgical options that can offer better view of the subdural space and may allow us to efficiently clear the loculations and haematoma fluid and thereby decreasing the incidence of recurrences and the need for reoperations. Small craniotomies have not been studied well in the literature except for a few publications. In this study, we are comparing mini craniotomy and burr hole evacuation for the treatment of chronic SDH. MATERIALS AND METHODS All the patients with chronic subdural haematoma operated between August 2013 and January 2016. Patients with recurrent SDH on the same side and patients who underwent different procedures on either side (in case of bilateral haematomas were excluded from the study. The patients were operated by two senior surgeons with one surgeon doing burr hole evacuation and another doing mini craniotomy. Preoperative status and postoperative status was analysed. RESULTS All the patients were analysed both preoperatively and postoperatively. In both the groups, most of the patients shown improvement following surgery, but recurrences are more in burr hole group when compared to mini craniotomy. CONCLUSION Mini craniotomy allows better view of the subdural space and better evacuation of chronic subdural haematoma. Cure rate is higher with mini craniotomy compared to burr hole evacuation.

  19. Mini Games for Professional Awareness in Introductory Psychology

    NARCIS (Netherlands)

    Hummel, Hans; Nadolski, Rob; Eshuis, Jannes; Slootmaker, Aad

    2017-01-01

    Main problems with the current course Introduction to Psychology in our university is that students consider the content as too theoretical and insufficient in providing professional practice. Potential solutions are expected to come from mini-games that have proven to enable more active and

  20. A magnetic-lens - mini-orange coincidence spectrometer

    International Nuclear Information System (INIS)

    Bargholtz, C.; Holmberg, L.; Ruus, N.; Tegner, P.E.; Weiss, G.

    1997-04-01

    A coincidence spectrometer consisting of a Gerholm type magnetic lens and a permanent magnet mini-orange spectrometer is described. Electron-electron or electron-positron coincidences may be registered in various angular settings. The spectrometer has been developed mainly to search for anomalous contributions to Bhabha scattering or positrons and is at present used for such studies. 6 refs

  1. Preliminary study on weapon grade uranium utilization in molten salt reactor miniFUJI

    Energy Technology Data Exchange (ETDEWEB)

    Aji, Indarta Kuncoro [Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung (Indonesia); Waris, A., E-mail: awaris@fi.itb.ac.id [Nuclear Physics and Biophysics Research Division, Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesa No. 10 Bandung 40132 (Indonesia)

    2014-09-30

    Preliminary study on weapon grade uranium utilization in 25MWth and 50MWth of miniFUJI MSR (molten salt reactor) has been carried out. In this study, a very high enriched uranium that we called weapon grade uranium has been employed in UF{sub 4} composition. The {sup 235}U enrichment is 90 - 95 %. The results show that the 25MWth miniFUJI MSR can get its criticality condition for 1.56 %, 1.76%, and 1.96% of UF{sub 4} with {sup 235}U enrichment of at least 93%, 90%, and 90%, respectively. In contrast, the 50 MWth miniFUJI reactor can be critical for 1.96% of UF{sub 4} with {sup 235}U enrichment of at smallest amount 95%. The neutron spectra are almost similar for each power output.

  2. Implementation of a linear mini accelerator for radiotherapy intraoperative

    International Nuclear Information System (INIS)

    Macias-Verde, D.; Yanez-Lopez, D.; Marti-Asenjo, J.; Sanchez-Carrascal, M.; Torres-Pozas, S.; Godoy-Cazorla, J. I.; Madan-Rodriguez, C.; Martin-Oliva, R.

    2013-01-01

    Has been defined the status initial reference of the lineal mini-accelerator Intrabeam PRS 500. The alternative worksheet in times of treatment provides an additional verification. The system is validated for clinical use. (Author)

  3. African Journal of Finance and Management: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Finance and Management: Journal Sponsorship. Journal Home > About the Journal > African Journal of Finance and Management: Journal Sponsorship. Log in or Register to get access to full text downloads.

  4. Scopus: Journal of East African Ornithology: Journal Sponsorship

    African Journals Online (AJOL)

    Scopus: Journal of East African Ornithology: Journal Sponsorship. Journal Home > About the Journal > Scopus: Journal of East African Ornithology: Journal Sponsorship. Log in or Register to get access to full text downloads.

  5. East African Journal of Public Health: Journal Sponsorship

    African Journals Online (AJOL)

    East African Journal of Public Health: Journal Sponsorship. Journal Home > About the Journal > East African Journal of Public Health: Journal Sponsorship. Log in or Register to get access to full text downloads.

  6. Science, Technology and Arts Research Journal: Journal Sponsorship

    African Journals Online (AJOL)

    Science, Technology and Arts Research Journal: Journal Sponsorship. Journal Home > About the Journal > Science, Technology and Arts Research Journal: Journal Sponsorship. Log in or Register to get access to full text downloads.

  7. African Journal of Oral Health Sciences: Journal Sponsorship

    African Journals Online (AJOL)

    African Journal of Oral Health Sciences: Journal Sponsorship. Journal Home > About the Journal > African Journal of Oral Health Sciences: Journal Sponsorship. Log in or Register to get access to full text downloads.

  8. South African Journal of Sports Medicine: Journal Sponsorship

    African Journals Online (AJOL)

    South African Journal of Sports Medicine: Journal Sponsorship. Journal Home > About the Journal > South African Journal of Sports Medicine: Journal Sponsorship. Log in or Register to get access to full text downloads.

  9. Journal of History and Diplomatic Studies: Journal Sponsorship

    African Journals Online (AJOL)

    Journal of History and Diplomatic Studies: Journal Sponsorship. Journal Home > About the Journal > Journal of History and Diplomatic Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  10. West African Journal of Applied Ecology: Journal Sponsorship

    African Journals Online (AJOL)

    West African Journal of Applied Ecology: Journal Sponsorship. Journal Home > About the Journal > West African Journal of Applied Ecology: Journal Sponsorship. Log in or Register to get access to full text downloads.

  11. Assessment of Paclobutrazol’s Time and Concentration of Foliar Application on Production and Germination of Potato (Solanum tuberosum L. Mini-tube

    Directory of Open Access Journals (Sweden)

    B Saadatian

    2018-02-01

    Full Text Available Introduction Health and quality of potato (Solanum tuberosum L. seeds are important in the potato seed production technology. Moreover, the basic seed materials must be free of pathogens. Therefore tissue culture techniques are used at this stage in the laboratory to produce disease free seeds. Mini-tubers can be produced after acclimatization from plantlets as tissue culture which are planted at high densities in the greenhouse in beds or containers using different substrate mixtures, or even in hydroponic culture. Foliar application of growth regulators is a way to increase potato mini-tuber production. Growth regulators influence on potato mini-tuber dormancy. Triazoles, a family which Paclobutrazol belongs to them, have both fungitoxic and plant growth regulatory effects. In addition, they can also protect plants against various stresses. Therefore, the triazoles have been characterized as plant multi-protestants. Paclobutrazol changes the relationship between source and sink and by this way, affects plant production. Also, it can inhibit giberellic acid biosynthesis. Some morphological changes observed in paclobutrazol-treated plants include the inhibition of plant growth, decreased inter-nodal elongation and increased root to shoot ratios. Time of paclobutrazol foliar application is an important factor which changes plant characters (Lim et al., 2004. This study implemented to evaluate foliar application of paclobutrazol concentrations at different time on production and mini-tuber dormancy. Materials and Methods The factorial experiment based on randomized complete block design with four replications was conducted at the faculty of agriculture’s research greenhouse, Ferdowsi University of Mashhad, Iran, in 2013. Plantlets of Agria cv. produced from nodal tissue culture in Murashinge and Skoog (MS medium. After 25 days, plantlets of free disease and uniform exported to plastic pots with 12 cm diameter and 30 cm height. Perlite, cocopite

  12. New Egyptian Journal of Microbiology: About this journal

    African Journals Online (AJOL)

    New Egyptian Journal of Microbiology: About this journal. Journal Home > New Egyptian Journal of Microbiology: About this journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue ...

  13. International Journal of Development and Policy Studies: Journal ...

    African Journals Online (AJOL)

    International Journal of Development and Policy Studies: Journal Sponsorship. Journal Home > About the Journal > International Journal of Development and Policy Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  14. Western Indian Ocean Journal of Marine Science: Journal ...

    African Journals Online (AJOL)

    Western Indian Ocean Journal of Marine Science: Journal Sponsorship. Journal Home > About the Journal > Western Indian Ocean Journal of Marine Science: Journal Sponsorship. Log in or Register to get access to full text downloads.

  15. Lagos Journal of Library and Information Science: Journal ...

    African Journals Online (AJOL)

    Lagos Journal of Library and Information Science: Journal Sponsorship. Journal Home > About the Journal > Lagos Journal of Library and Information Science: Journal Sponsorship. Log in or Register to get access to full text downloads.

  16. Tanzania Journal of Forestry and Nature Conservation: Journal ...

    African Journals Online (AJOL)

    Tanzania Journal of Forestry and Nature Conservation: Journal Sponsorship. Journal Home > About the Journal > Tanzania Journal of Forestry and Nature Conservation: Journal Sponsorship. Log in or Register to get access to full text downloads.

  17. Case Study: Mini-Case Studies: Small Infusions of Active Learning for Large-Lecture Courses

    Science.gov (United States)

    Carloye, Lisa

    2017-01-01

    In this article, the author introduces the usage of case studies to be an excellent method for engaging students through stories. The author notes she developed a series of mini-case studies that can be implemented, with a little advance preparation, within a 10- to 15-minute window during lecture. What makes them "mini" case studies?…

  18. Levan And Levansucrase-A Mini Review

    Directory of Open Access Journals (Sweden)

    Bruna Caroline Marques Goncalves

    2015-05-01

    Full Text Available Abstract Levansucrase is a fructosyltranferase that synthesizes levan and present great biotechnological interest. Its being widely used in therapeutic food cosmetic and pharmaceutical industries. Levansucrase is produced by many microorganisms such as the Bacillus subtilis Natto using the sucrose fermentation. In this mini-review we described some properties and functions of this important group of enzymes and the recent technologies used in the production and purification of levansucrase and levan.

  19. Trapped magnetic field of a mini-bulk magnet using YBaCuO at 77 K

    Science.gov (United States)

    Fujimoto, Hiroyuki; Kamijo, Hiroki

    2001-09-01

    Melt-processed rare earth (RE)123 superconductors have a high Jc at 77 K and high magnetic field. Solidification processes for producing (L)RE123 superconductors and pinning centers in the (L)RE123 matrix are effective for obtaining high Jc, leading to high-field application as a superconducting quasi-permanent bulk magnet with the liquid nitrogen refrigeration. One of the promising applications is a superconducting magnet for the magnetically levitated train. We fabricated a mini-superconducting bulk magnet of 200×100 mm2, consisting of 18 bulks, which are a square 33 mm on a side and 10 mm in thickness, and magnetized the mini-magnet by field cooling. The mini-magnet showed the trapped magnetic field of larger than 0.1 T on the surface of the outer vessel of the magnet. The present preliminary study discusses trapped magnetic field properties of the mini-bulk magnet using YBaCuO superconductors at 77 K.

  20. Observation of rat's colon polyps in real time by mini-endoscopy and raman spectroscopy

    Science.gov (United States)

    Andriana, Bibin Bintang; Mahardika, Anggara; Taketani, Akihiro; Sato, Hidetoshi

    2018-02-01

    Colorectal adenoma (CA) is a disease caused by various factors (such as genetic factors or environmental exposures). The appearance of colon polyp (CP) within colorectal might indicate the hint of CA development. Ball-lens hollow fiber Raman probe (BHRP) may has a high capability for detection of CA in living experimental animal and have already tested to rat's CP in this study, which was designed to collaborate between BHRP with mini-endoscopy to observe the biochemical alteration within normal colon tissue and rat's colon polyps in real time. BHRP and mini-endoscopy can distinguish the differences in their finger print spectra and make pictures the control and CP in the real time. At the first step, the real situation of normal colon and Rat's CP were washed by saline and observed with mini-endoscopy. BHRP was introduced to Dextran sodium sulphate (DSS)-induced Rat's CP to detect some of biochemical alteration. The main purpose of this study was to introduce mini-endoscopy to guide the BHRP for diagnosing of CP in real time and to compare it with spectra of normal colon (control group) in living rat. As the result, BHRP can provide the differences in band of control and CP group, which can inform that the biochemical of normal and CP has changed. As a major parameter to distinct normal and CP tissue were phosphatidylinositol, phosphodiester group, lipid, and collagen. Mini endoscopy and BHRP is very sensitive devices for diagnosing of CP in real time.

  1. The performance of the Mini-Cog in a sample of low educational level elderly

    Directory of Open Access Journals (Sweden)

    Sergio Telles Ribeiro Filho

    Full Text Available Abstract Objectives: To study the criterion validity of the Mini-Cog in low educational level elderly. Design: Cross-sectional and validation design. Setting: Policlínica Piquet Carneiro, an outpatient unit of Rio de Janeiro State University Hospital, in Brazil. Participants: A convenient sample consisting of 306 individuals, 65 yrs or older, selected from April 8th to July 15th, 2002. Methods: All participants underwent comprehensive geriatric evaluations which included the Mini-Mental State Examination (MMSE and the cognitive part of the Cambridge Examination for Mental Disorders of the Elderly - Revised (CAMCOG-R. They were classified as demented or non-demented (DSM-IV. A post-hoc analysis was performed on the data from the 3 word recall test of the MMSE, and the Clock Drawing Test from the CAMCOG-R, and respective scores were added and interpreted in accordance with the Mini-Cog protocol. Results: 293 individuals completed all the study steps; 211 had 4 or less years of schooling and were included in the data analysis. 32% had dementia. Mini-Cog sensitivity and specificity was consistently low independently of the different cut-off points considered. The best performance was found at the cut-off point of 2/3 which yielded sensitivity and specificity of 60% and 65%, respectively. Conclusion: The Mini-Cog is not a good cognitive screening tool for individuals with less than five years of formal education.

  2. Vaporization inside a mini microfin tube: experimental results and modeling

    Science.gov (United States)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  3. Comparison of flexible ureterorenoscopy and mini-percutaneous nephrolithotomy in treatment of lower calyceal stones smaller than 2 cm.

    Science.gov (United States)

    Akbulut, Fatih; Kucuktopcu, Onur; Kandemir, Emre; Sonmezay, Erkan; Simsek, Abdulmuttalip; Ozgor, Faruk; Binbay, Murat; Muslumanoglu, Ahmet Yaser; Gurbuz, Gokhan

    2016-01-01

    To compare the outcomes of flexible ureterorenoscopy (F-URS) and mini-percutaneous nephrolithotomy (mini-PNL) in the treatment of lower calyceal stones smaller than 2 cm. Patients who underwent F-URS and mini-PNL for the treatment of lower calyceal stones smaller than 2 cm between March 2009 and December 2014 were retrospectively evaluated. Ninety-four patients were divided into two groups by treatment modality: F-URS (Group 1: 63 patients) and mini-PNL (Group 2: 31 patients). All patients were preoperatively diagnosed with intravenous pyelography or computed tomography. Success rates for F-URS and mini-PNL at postoperative first month were 85.7% and 90.3%, respectively. Operation time, fluoroscopy time, and hospitalization time for F-URS and mini-PNL patients were 44.40 min, 2.9 min, 22.4 h, and 91.9 min, 6.4 min, and 63.8 h, respectively. All three parameters were significantly shorter among the F-URS group (p PNL group (0.39 mg/dL vs. 1.15 mg/dL, p = 0.001). A comparison of complications according to the Clavien classification demonstrated significant differences between the groups (p = 0.001). More patients in the F-URS groups require antibiotics due to urinary tract infection, and more patients in the mini-PNL group required ureteral double J catheter insertion under general anesthesia. Although both F-URS and mini-PNL have similar success rates for the treatment of lower calyceal stones, F-URS appears to be more favorable due to shorter fluoroscopy and hospitalization times; and lower hemoglobin drops. Multicenter and studies using higher patient volumes are needed to confirm these findings.

  4. Vacuum design for a superconducting mini-collider

    International Nuclear Information System (INIS)

    Barletta, W.A.; Monteiro, S.

    1991-01-01

    The phi factory (Superconducting Mini-Collider or SMC) proposed for construction at UCLA is a single storage ring with circulating currents of 2 A each of electrons and positrons. The small circumference exacerbates the difficulties of handling the gas load due to photodesorption from the chamber walls. The authors analyze the vacuum system for the phi factory to specify design choices

  5. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources

    International Nuclear Information System (INIS)

    Oliveira, Mercia L; Caldas, Linda V E

    2005-01-01

    90 Sr+ 90 Y applicators are commonly utilized in brachytherapy, including ophthalmic procedures. The recommended instruments for the calibration of these applicators are extrapolation chambers, which are ionization chambers that allow the variation of their sensitive volume. Using the extrapolation method, the absorbed dose rate at the applicator surface can be determined. The aim of the present work was to develop a mini-extrapolation chamber for the calibration of 90 Sr+ 90 Y beta ray applicators. The developed mini-chamber has a 3.0 cm outer diameter and is 11.3 cm in length. An aluminized polyester foil is used as the entrance window while the collecting electrode is made of graphited polymethylmethacrylate. This mini-chamber was tested in 90 Sr+ 90 Y radiation beams from a beta particle check source and with a plane ophthalmic applicator, showing adequate results

  6. Cooling down MiniGRAIL to milli-Kelvin temperatures

    NARCIS (Netherlands)

    de Waard, A.; de Waard, A.; Gottardi, L.; Bassan, M.; Coccia, E.; Fafone, V.; Flokstra, Jakob; Karbalai-Sadegh, A.; Minenkov, Y.; Moleti, A.; Pallottino, G.V.; Podt, M.; Pors, B.J.; Reincke, W; Rocchi, A.; Shumack, A.; Srinivas, S.; Visco, M.; Frossati, G.

    2004-01-01

    The latest developments in the construction of the ultra-cryogenic spherical detector MiniGRAIL are presented. The room temperature part of the vibration isolation system was improved and provided with an attenuation of about 60 dB around 3 kHz. The transfer function of the cryogenic stages gave

  7. Water Boiler Change-Over in Mini-TPP Mode

    Directory of Open Access Journals (Sweden)

    B. A. Bayrashevsky

    2011-01-01

    Full Text Available The paper considers water boiler modernization by its change-over in mini-TPP mode with an expansion tank and a heating turbine of small capacity.  A software complex permitting to evaluate competitive ability of such water boiler modernization in comparison with a cogeneration plant.

  8. International Journal of Humanistic Studies: About this journal

    African Journals Online (AJOL)

    International Journal of Humanistic Studies: About this journal. Journal Home > International Journal of Humanistic Studies: About this journal. Log in or Register to get access to full text downloads.

  9. Tropical Journal of Pharmaceutical Research: About this journal

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research: About this journal. Journal Home > Tropical Journal of Pharmaceutical Research: About this journal. Log in or Register to get access to full text downloads.

  10. Nigerian Journal of Pharmaceutical Research: About this journal

    African Journals Online (AJOL)

    Nigerian Journal of Pharmaceutical Research: About this journal. Journal Home > Nigerian Journal of Pharmaceutical Research: About this journal. Log in or Register to get access to full text downloads.

  11. Good journalism or peace journalism?

    OpenAIRE

    David Loyn

    2007-01-01

    This paper argues against the prescriptive notions of Peace Journalism, and in particular its exclusive nature and attempt to define itself as a new orthodoxy. Most of the paper is a critique of the work of Jake Lynch and Annabel McGoldrick, in a book published in 2005, as well as their earlier Reporting the World series. They condemn all other ways of reporting as 'War Journalism, biased in favour of war.' I argue instead that the opposite of Peace Journalism is good journalism. Much of ...

  12. Acceptability and feasibility of mini-clinical evaluation exercise as a formative assessment tool for workplace-based assessment for surgical postgraduate students

    Directory of Open Access Journals (Sweden)

    M K Joshi

    2017-01-01

    Full Text Available Background: Despite an increasing emphasis on workplace-based assessment (WPBA during medical training, the existing assessment system largely relies on summative assessment while formative assessment is less valued. Various tools have been described for WPBA, mini-clinical evaluation exercise (mini-CEX being one of them. Mini-CEX is well accepted in Western countries, however, reports of its use in India are scarce. We conducted this study to assess acceptability and feasibility of mini-CEX as a formative assessment tool for WPBA of surgical postgraduate students in an Indian setting. Methods: Faculty members and 2nd year surgical residents were sensitized toward mini-CEX and requisite numbers of exercises were conducted. The difficulties during conduction of these exercises were identified, recorded, and appropriate measures were taken to address them. At the conclusion, the opinion of residents and faculty members regarding their experience with mini-CEX was taken using a questionnaire. The results were analyzed using simple statistical tools. Results: Nine faculty members out of 11 approached participated in the study (81.8%. All 16 2nd year postgraduate surgical residents participated (100%. Sixty mini-CEX were conducted over 7 months. Each resident underwent 3–5 encounters. The mean time taken by the assessor for observation was 12.3 min (8–30 min while the mean feedback time was 4.2 min (3–10 min. The faculty reported good overall satisfaction with mini-CEX and found it acceptable as a formative assessment tool. Three faculty members (33.3% reported mini-CEX as more time-consuming while 2 (22.2% found it difficult to carry the exercises often. All residents accepted mini-CEX and most of them reported good to high satisfaction with the exercises conducted. Conclusions: Mini-CEX is well accepted by residents and faculty as a formative assessment tool. It is feasible to utilize mini-CEX for WPBA of postgraduate students of surgery.

  13. Identifying the most efficient items from the Mini-Mental State Examination for cognitive function assessment in older Taiwanese patients.

    Science.gov (United States)

    Lou, Meei-Fang; Dai, Yu-Tzu; Huang, Guey-Shiun; Yu, Po-Jui

    2007-03-01

    The purpose of the study was to identify the most efficient items from the Mini-Mental State Examination for assessment of cognitive function. The Mini-Mental State Examination is the most frequently used cognitive screening instrument. However, the Mini-Mental State Examination has been criticized for insensitivity to mild cognitive dysfunction, limited memory assessment and variability in level of difficulty of the individual items. This study used secondary data analysis. Item response theory two-parameter model was used to analyse the data from the admission assessment of mental status by the Mini-Mental State Examination for 801 patients. By using item response analysis, 16 items were selected from the original 30-item Mini-Mental State Examination. The 16 items included mainly the measures of orientation, recall and attention and calculation. The internal consistency of the 16-item Mini-Mental State Examination was 0.84. The proposed new cut-off point for the 16-item Mini-Mental State Examination was 11. The correct classification rate was 0.94, the sensitivity was 100% and the specificity was 97.4%, when compared with the original 30-item Mini-Mental State Examination from the cut-off point of 24. This new cut-off point was determined for the purpose of over-identifying patients at risk so as to ensure early detection of and prevention from the onset of cognitive disturbance. Only a few items are needed to describe the subject's cognitive status. Using item response theory analysis, the study found that the Mini-Mental State Examination could be simplified. Deleting the items with less variation makes this assessment tool not only shorter, easier to administer and less strenuous for respondents, but also enables one to maintain validity as a cognitive function test for clinical setting.

  14. Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study

    Directory of Open Access Journals (Sweden)

    Zohreh Hedayati

    2016-10-01

    Full Text Available Abstract Background Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. Methods A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. Results Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. Conclusions According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.

  15. Orthodontic intrusion : Conventional and mini-implant assisted intrusion mechanics

    Directory of Open Access Journals (Sweden)

    Anup Belludi

    2012-01-01

    intrusion has revolutionized orthodontic anchorage and biomechanics by making anchorage perfectly stable. This article addresses various conventional clinical intrusion mechanics and especially intrusion using mini-implants that have proven effective over the years for intrusion of maxillary anteriors.

  16. AplikasiRekayasa Nilai Untuk Evaluasi Produk Mesin Compos Mini Produksi

    Directory of Open Access Journals (Sweden)

    Abdul Aziz

    2010-10-01

    Full Text Available A product can look like a system, which is something that still has room for consideration of revisions (evaluation. In the evaluation, value engineering is one technique that systematically by using the techniques of identification of the functions required, apply the values and develop alternatives that achieve the best functional balance between cost and performance of a system or product. In compos Mini Machine products, value engineering done to the component cost is quite high (grade A on the ABC classification. Benefit Cost Ratio (BCR is an important thing that needs to be calculated on the value engineering. The selected alternative for this article is the replacement of roofing material from metal plate to the plastic pulley with cost savings of 55%. Keywords: Value engineering, product evaluation, BCR

  17. Validity and applicability of the Mini International Neuropsychiatric Interview administered by family medicine residents in primary health care in Brazil.

    Science.gov (United States)

    de Azevedo Marques, João Mazzoncini; Zuardi, Antonio W

    2008-01-01

    To evaluate the validity and applicability of the Mini International Neuropsychiatric Interview (MINI) used by family medicine residents in primary health care (PHC) in Brazil. Training for administrating the MINI was given as part of a broad psychiatry education program. Interviews were held with 120 PHC patients who were at least 15 years old. MINI was administered by 25 resident physicians, while the Structured Clinical Interview for Diagnosis (SCID) was administered by a psychiatrist blind to patients' results on the MINI, and the diagnoses on both interviews were compared. The resident physicians answered questions on the applicability of the MINI. Concordance levels for any mental disorder, the broader current diagnostic categories and the most common specific diagnoses were analyzed. Kappa coefficients ranged between 0.65 and 0.85; sensitivity, between 0.75 and 0.92; specificity, between 0.90 and 0.99; positive predictive values (PPV), between 0.60 and 0.86; negative predictive values (NPV), between 0.92 and 0.99; and accuracy, between 0.88 and 0.98. The resident physicians considered MINI comprehensibility and clinical relevance satisfactory. These good psychometric results in a real-world setting may be related to a special training program, which is more frequent, intensive and diversified. In these conditions, the MINI is a useful tool for general practitioners.

  18. Beta-spectrometer with magnetic filter of mini orange type

    International Nuclear Information System (INIS)

    Gorozhankin, V.M.; Gromov, K.Ya.; Kalinnikov, V.G.; Sereeter, Z.; Fominykh, V.I.; Malikov, Sh.R.; Yuldashev, M.B.

    1997-01-01

    At the ISOL facility YASNAPP-2 a β-spectrometer with a magnetic filter of the miniorange type is constructed to measure γ-ray internal conversion coefficients. The magnetic filter of the mini orange type is an assemblage of permanent magnets creating a toroidal magnetic field perpendicular to the electron trajectories from the source to the Si(Li) detector. The chosen profile of the permanent magnets allowed electron registration in the defined energy energy interval with some transmission increase. There are two sets of permanent magnets of the different thickness. Varying the type and number of permanent magnets one can set the detected electron energy intervals in a 50-2500 keV range. The efficiency of the spectrometer was investigated for different assemblages of the mini orange magnet. The facility can be used for the e-γ coincidence investigation. (A.A.D.)

  19. Thermalization of mini-jets in a quark–gluon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Iancu, Edmond, E-mail: edmond.iancu@cea.fr; Wu, Bin, E-mail: bin.wu.phys@gmail.com [Institut de Physique Théorique, CEA Saclay, CNRS UMR 3681, F-91191 Gif-sur-Yvette (France); Department of Physics, The Ohio State University, Columbus, OH 43210 (United States)

    2016-12-15

    We present the complete physical picture for the evolution of a high-energy jet propagating through a weakly-coupled quark-gluon plasma (QGP) by analytical and numerical investigation of thermalization of the soft components of the jet. Our results support the following physical picture: the leading particle emits a significant number of mini-jets which promptly evolve via multiple branching and thus degrade into a myriad of soft gluons, with energies of the order of the medium temperature T. Via elastic collisions with the medium constituents, these soft gluons relax to local thermal equilibrium with the plasma over a time scale which is considerably shorter than the typical lifetime of the mini-jet. The thermalized gluons form a tail which lags behind the hard components of the jet. Together with the background QGP, they behave hydrodynamically.

  20. Rethinking Constructive Journalism by Means of Service Journalism

    DEFF Research Database (Denmark)

    From, Unni; Kristensen, Nete Nørgaard

    2018-01-01

    This article argues that constructive journalism scholarship should look to service journalism and its subfields, cultural journalism and lifestyle journalism, to understand key characteristics of this newer type of journalism. Though constructive journalism is typically associated...... with the reporting of political and social issues, it is also seen to challenge traditional ways of writing about such hard news topics due to its positive and solution-oriented approach. In this respect, constructive journalism seems to reuse some of the approaches known from service journalism, especially in terms...... of audience address and an expanded social role for journalists. However, service journalism emerged in the increasingly commercialized and globalized media landscape of the post-WW2-period, whereas constructive journalism has emerged in the digital media landscape of the 2010s. These historical contexts...

  1. Are mini DNA-barcodes sufficiently informative to resolve species ...

    Indian Academy of Sciences (India)

    ... between mini-barcode and the full- length DNA barcode was carried out in Microsoft Excel. (http://www.office.microsoft.com). ..... Received 15 June 2013, in final revised form 5 April 2014; accepted 3 June 2014. Unedited version published ...

  2. [Our experience with mini tapes (TVT Secur and MiniArc) in the surgery for stress urinary incontinence].

    Science.gov (United States)

    Jiménez Calvo, J; Hualde Alfaro, A; Raigoso Ortega, O; Cebrian Lostal, J L; Alvarez Bandres, S; Jiménez Parra, J; Montesino Semper, M; Santiago Gonzalez de Garibay, A

    2008-01-01

    The purpose of this publication is to describe the surgical technique, assess complications and short-term results of TVT secur and MiniArc tapes. From October 2006 to August 2007 it was carried out the surgical correction with TVT Secur,Women's Health & Urology, Ethicon, Johnson & Johnson, placing the tape as a hammock, to 51 patients, 38 of them with pure stress incontinence and 13 with mixed incontinence and with an average age of 57 years. From September 2007 to February 2008 41 patients, 33 of them with pure stress incontinence and 8 with mixed incontinence, with an average of age of 58 years were operated with AMS Miniarc swing system tape, posted on hammock. All procedures were performed with sedoanalgesia and Ambulatory Surgery regime. Patients were monitored in outpatient visits one month, 3 months and one year after surgical procedure. Medical history and questionnaire and ICIQ-SF, to which we added a question to quantify the degree of satisfaction, as well as physical examination, were done. We compared the results of both technical procedures and statistical survey was conducted by Student test. [Analysis with SPSS software (V14.0)]. The median follow-up in TVT secur group was 328 days (range 163-522 days) and 101 days (range 41-209 days) inthe MiniArc group. We only had one (TVT secur group) surgical complication in all the series (92 patients) being a bladder perforation. Taking into account that we read a negative test effort as an objective cure in the TVT secur group, 80.4% patients are cured and 90.2% inthe MiniArc group without significant difference between both groups (p 0095). To assess the subjective healing we utilized the ICIQ-SF test and the satisfaction extra-question and we noted that there is no significant difference between the first and third month controls. (90% of patients satisfied). 80% of patients were completely satisfied in the first year control that was only performed to TVT secur group. These new tapes show fewer

  3. Implementation of MINI-PACS using the DICOM converter on the Web

    International Nuclear Information System (INIS)

    Ji, Youn Sang

    2000-01-01

    In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, MINI-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed MINI-PACS consists of mainly four parts such as Web Module, Client-Server Module, Internal Module, Acquisition Module. In addition, MINI-PACS system includes DICOM Converter that Non-DICOM file format converts standard file format. In Client-Server Module case, Proposed system is combined both SCU(Service Class User: Client) part and SCP(Service Class Provider: Server) part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for Medium and Small hospitals to install and operate the full-PACS. Also, we constructed Web Module for database connection through the WWW.=20

  4. Mandibular Two Mini Implants Overdenture Using Magnetic Attachments: A Case Report

    Directory of Open Access Journals (Sweden)

    Anna Miyayasu

    2017-12-01

    Full Text Available Many patients with an edentulous mandible struggle to use complete dentures. The instability of such dentures caused by the lack of retention, often causes discomfort, as well as functional and psychosocial problems, which can be signifcantly improved using implant overdentures with retentive attachments. This case report describes a successful case of a mandibular implant overdenture using two mini implants and magnetic attachments for an elderly edentulous patient. Case Report: A 62-year-old female with a thin mandibular bone ridge presented with complaints of pain caused by an unstable and unretentive complete mandibular denture. This patient received two mini implants (diameter: 2.6 mm; length: 12 mm with magnetic attachments. After three months, magnetic assemblies with magnetic attraction of 400 gf were incorporated into the intaglio surface of her mandibular overdenture. At 11 months, magnetic attraction was changed from 400 gf to 600 gf to provide a stronger magnetic force for improving the retention of this denture. Conclusion: Based on a two-year follow-up period, the mandibular two mini implants overdenture with magnetic attachments was successful in improving the patient’s general satisfaction with her dentures

  5. Altered fibre types in gastrocnemius muscle of high wheel-running selected mice with mini-muscle phenotypes.

    Science.gov (United States)

    Guderley, Helga; Joanisse, Denis R; Mokas, Sophie; Bilodeau, Geneviève M; Garland, Theodore

    2008-03-01

    Selective breeding of mice for high voluntary wheel running has favoured characteristics that facilitate sustained, aerobically supported activity, including a "mini-muscle" phenotype with markedly reduced hind limb muscle mass, increased mass-specific activities of oxidative enzymes, decreased % myosin heavy chain IIb, and, in the medial gastrocnemius, reduced twitch speed, reduced mass-specific isotonic power, and increased fatigue resistance. To evaluate whether selection has altered fibre type expression in mice with either "mini" or normal muscle phenotypes, we examined fibre types of red and white gastrocnemius. In both the medial and lateral gastrocnemius, the mini-phenotype increased activities of oxidative enzymes and decreased activities of glycolytic enzymes. In red muscle samples, the mini-phenotype markedly changed fibre types, with the % type I and type IIA fibres and the surface area of type IIA fibres increasing; in addition, mice from selected lines in general had an increased % type IIA fibres and larger type I fibres as compared with mice from control lines. White muscle samples from mini-mice showed dramatic structural alterations, with an atypical distribution of extremely small, unidentifiable fibres surrounded by larger, more oxidative fibres than normally present in white muscle. The increased proportion of oxidative fibres and these atypical small fibres together may explain the reduced mass and increased mitochondrial enzyme activities in mini-muscles. These and previous results demonstrate that extension of selective breeding beyond the time when the response of the selected trait (i.e. distance run) has levelled off can still modify the mechanistic underpinnings of this behaviour.

  6. Factors Influencing Mini-CEX Rater Judgments and Their Practical Implications: A Systematic Literature Review.

    Science.gov (United States)

    Lee, Victor; Brain, Keira; Martin, Jenepher

    2017-06-01

    At present, little is known about how mini-clinical evaluation exercise (mini-CEX) raters translate their observations into judgments and ratings. The authors of this systematic literature review aim both to identify the factors influencing mini-CEX rater judgments in the medical education setting and to translate these findings into practical implications for clinician assessors. The authors searched for internal and external factors influencing mini-CEX rater judgments in the medical education setting from 1980 to 2015 using the Ovid MEDLINE, PsycINFO, ERIC, PubMed, and Scopus databases. They extracted the following information from each study: country of origin, educational level, study design and setting, type of observation, occurrence of rater training, provision of feedback to the trainee, research question, and identified factors influencing rater judgments. The authors also conducted a quality assessment for each study. Seventeen articles met the inclusion criteria. The authors identified both internal and external factors that influence mini-CEX rater judgments. They subcategorized the internal factors into intrinsic rater factors, judgment-making factors (conceptualization, interpretation, attention, and impressions), and scoring factors (scoring integration and domain differentiation). The current theories of rater-based judgment have not helped clinicians resolve the issues of rater idiosyncrasy, bias, gestalt, and conflicting contextual factors; therefore, the authors believe the most important solution is to increase the justification of rater judgments through the use of specific narrative and contextual comments, which are more informative for trainees. Finally, more real-world research is required to bridge the gap between the theory and practice of rater cognition.

  7. Mini buffy coat photopheresis for children and critically ill patients with extracorporeal photopheresis contraindications.

    Science.gov (United States)

    Hackstein, Holger; Misterek, Joachim; Nockher, Angelika; Reiter, Alfred; Bein, Gregor; Woessmann, Willi

    2009-11-01

    Conventional extracorporeal photopheresis (ECP) has proven efficacy for the treatment of several diseases but is limited to patients with sufficient body weight. A novel simplified mini buffy coat ECP technique that allows treatment of small children and patients with apheresis contraindications has been developed. White blood cell (WBC)-rich buffy coat fractions were prepared from 5 to 8 mL/kg whole blood in a closed system, diluted, and ultraviolet A (UVA)-irradiated after addition of 8-methoxypsoralen (8-MOP). Apoptosis and cell death were analyzed by annexin V and 7-aminoactinomycin staining. Lymphocyte proliferation was measured after CD3/CD28 and phytohemagglutinin (PHA) stimulation. Autologous residual blood and UVA-irradiated buffy coat were returned to the patients. Fifty-six mini buffy coat ECP procedures were applied to three children with acute steroid-refractory skin graft-versus-host disease and apheresis contraindications. Mean whole blood and buffy coat volumes were 166 (+/-61.8) and 8 (+/-1.6) mL, respectively, and resulted in a hematocrit of 2.2% (+/-0.4) after saline dilution (median +/- SD). UVA irradiation of 8-MOP buffy coat preparations resulted in significant induction of WBC apoptosis at 48-72 hours (p laboratory side effects were observed during mini ECP procedures and the three patients responded to the therapy. Mini buffy coat ECP induces apoptosis and lymphocyte proliferation inhibition, both of which occur after standard ECP. This study proposes that mini buffy coat ECP be used as a simple and inexpensive alternative to classical ECP in children and adult patients with apheresis contraindications.

  8. Matrix-mini-tablets of lornoxicam for targeting early morning peak symptoms of rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Abdul Hadi Mohd

    2014-05-01

    Full Text Available Objective(s: The aim of present research was to develop matrix-mini-tablets of lornoxicam filled in capsule for targeting early morning peak symptoms of rheumatoid arthritis. Materials and Methods:Matrix-mini-tablets of lornoxicam were prepared by direct compression method using microsomal enzyme dependent and pH-sensitive polymers which were further filled into an empty HPMC capsule. To assess the compatibility, FT-IR and DSC studies for pure drug, polymers and their physical mixture were performed. The formulated batches were subjected to physicochemical studies, estimation of drug content, in vitro drug release, drug release kinetics, and stability studies. Results:  When FTIR and DSC studies were performed it was found that there was no interaction between lornoxicam and polymers which used. All the physicochemical properties of prepared matrix-mini-tablets were found to be in normal limits. The percentage of drug content was found to be 99.60±0.07%. Our optimized matrix mini-tablets-filled-capsule formulation F30 released lornoxicam after a lag time of 5.02±0.92 hr, 95.48±0.65 % at the end of 8 hr and 99.90±0.83 % at the end of 12 hr. Stability was also found for this formulation as per the guidelines of International Conference on Harmonisation of Technical Requirements of Pharmaceuticals for Human Use. Conclusion: A novel colon targeted delivery system of lornoxicam was successfully developed by filling matrix-mini-tablets into an empty HPMC capsule shell for targeting early morning peak symptoms of rheumatoid arthritis.

  9. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    Franchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret. This research aims to identify the IPR which the franchise's object between franchisor and franchisee in the mini mark...

  10. Civil mini-RPA's for the 1980's: Avionics design considerations. [remotely piloted vehicles

    Science.gov (United States)

    Karmarkar, J. S.

    1975-01-01

    A number of remote sensing or surveillance tasks (e.g., fire fighting, crop monitoring) in the civilian sector of our society may be performed in a cost effective manner by use of small remotely piloted aircraft (RPA). This study was conducted to determine equipment (and the associated technology) that is available, and that could be applied to the mini-RPA and to examine the potential applications of the mini-RPA with special emphasis on the wild fire surveillance mission. The operational considerations of using the mini-RPA as affected by government regulatory agencies were investigated. These led to equipment requirements (e.g., infra-red sensors) over and above those for the performance of the mission. A computer technology survey and forecast was performed. Key subsystems were identified, and a distributed microcomputer configuration, that was functionally modular, was recommended. Areas for further NASA research and development activity were also identified.

  11. Primary Stability of Self-Drilling and Self-Tapping Mini-Implant in Tibia of Diabetes-Induced Rabbits

    Directory of Open Access Journals (Sweden)

    Jea-Beom Park

    2014-01-01

    Full Text Available Objective. This study aimed to evaluate effects of type 1 diabetes mellitus and mini-implant placement method on the primary stability of mini-implants by comparing mechanical stability and microstructural/histological differences. Methods. After 4 weeks of diabetic induction, 48 mini-implants (24 self-tapping and 24 self-drilling implants were placed on the tibia of 6 diabetic and 6 normal rabbits. After 4 weeks, the rabbits were sacrificed. Insertion torque, removal torque, insertion energy, and removal energy were measured with a surgical engine on 8 rabbits. Remaining 4 rabbits were analyzed by microcomputed tomography (micro-CT and bone histomorphometry. Results. Total insertion energy was higher in self-drilling groups than self-tapping groups in both control and diabetic groups. Diabetic groups had more trabecular separation in bone marrow than the control groups in both SD and ST groups. Micro-CT analysis showed deterioration of bone quality in tibia especially in bone marrow of diabetic rabbits. However, there was no statistically significant correlation between self-drilling and self-tapping group for the remaining measurements in both control and diabetic groups. Conclusions. Type 1 diabetes mellitus and placement method of mini-implant did not affect primary stability of mini-implants.

  12. Ultra-mini-percutaneous nephrolithotomy in pediatric nephrolithiasis: both low pressure and high efficiency.

    Science.gov (United States)

    Dede, Onur; Sancaktutar, Ahmet Ali; Dağguli, Mansur; Utangaç, Mazhar; Baş, Okan; Penbegul, Necmettin

    2015-10-01

    The management of urolithiasis in children differs from adults because of anatomic and metabolic abnormalities. At present, various minimally invasive and invasive treatment strategies have been recommended to treat urinary tract Stones, including shock wave lithotripsy (SWL), standard percutaneous nephrolithotomy (PNL), mini-PNL, retrograde intrarenal surgery (RIRS), micro-PNL, and a new technique termed ultra-mini PNL (UMP). UMP is a new method for the treatment of kidney stones. The main difference between UMP and standard PNL or mini-PNL lies in the small access sheath and in its design. A 9.5F pediatric compact cystoscope was used (Figure). A major advantage of UMP is that it provides similar stone-free rates when compared with standard PNL, with lower intrarenal pressure than micro-PNL. The aim of the study was to determine the applicability and safety of UMP in the treatment of pediatric kidney stones. We retrospectively reviewed the files of 39 kidney stones in children who had undergone UMP between May 2011 and October 2014. The indications for UMP included stones resistant to SWL, stones requiring repeated sessions of SWL, and stones size larger than 20 mm. The study included 17 females and 22 males, with a mean age of 5.8 ± 4.6 years. The mean hemoglobin loss was 0.9 ± 0.6 mg/dL and none of the patients required a blood transfusion. The complication rate of the PNL procedure was 15.3% (n = 6). Complete clearance was achieved in 32 patients (82%) with UMP monotherapy, which increased to 34% (87.1%) 4 weeks after the operation. Management of urolithiasis necessitates a balance between stone clearance and morbidity related to the procedure. SWL often leads to persistent residual stones. The developing RIRS can minimize the risks associated with bleeding and visceral injury, but sometimes the abnormal pelvicaliceal anatomy and poor imaging of the flexible ureteroscopy may impact its success rate and applications. It has been reported that PNL can be

  13. South African Journal of Bioethics and Law: Journal Sponsorship

    African Journals Online (AJOL)

    South African Journal of Bioethics and Law: Journal Sponsorship. Journal Home > About the Journal > South African Journal of Bioethics and Law: Journal Sponsorship. Log in or Register to get access to full text downloads.

  14. Journal of Computer Science and Its Application: Journal Sponsorship

    African Journals Online (AJOL)

    Journal of Computer Science and Its Application: Journal Sponsorship. Journal Home > About the Journal > Journal of Computer Science and Its Application: Journal Sponsorship. Log in or Register to get access to full text downloads.

  15. Nigeria Journal of Pure and Applied Physics: Journal Sponsorship

    African Journals Online (AJOL)

    Nigeria Journal of Pure and Applied Physics: Journal Sponsorship. Journal Home > About the Journal > Nigeria Journal of Pure and Applied Physics: Journal Sponsorship. Log in or Register to get access to full text downloads.

  16. OGIRISI: a New Journal of African Studies: Journal Sponsorship

    African Journals Online (AJOL)

    OGIRISI: a New Journal of African Studies: Journal Sponsorship. Journal Home > About the Journal > OGIRISI: a New Journal of African Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  17. Mini-projects in Chemical Engineering Laboratory

    Directory of Open Access Journals (Sweden)

    Angeles Cancela

    2013-03-01

    Full Text Available Chemical engineering laboratory practices based in mini-projects were design and applied the students of forestry engineering in chemical subject. This way of practice reveals a more cooperative learning and a different style of experimentation. The stated goal was to design practices that motivate students and to enable them to develop different skills, including cross teamwork and communication. This paper describes how these practices were developed and the advantages and disadvantages of using this methodology of teaching.

  18. Journal of Research in Forestry, Wildlife and Environment: Journal ...

    African Journals Online (AJOL)

    Journal of Research in Forestry, Wildlife and Environment: Journal Sponsorship. Journal Home > About the Journal > Journal of Research in Forestry, Wildlife and Environment: Journal Sponsorship. Log in or Register to get access to full text downloads.

  19. Journal of the Nigerian Association of Mathematical Physics: Journal ...

    African Journals Online (AJOL)

    Journal of the Nigerian Association of Mathematical Physics: Journal Sponsorship. Journal Home > About the Journal > Journal of the Nigerian Association of Mathematical Physics: Journal Sponsorship. Log in or Register to get access to full text downloads.

  20. Characterization of a mini-channel heat exchanger for a heat pump system

    International Nuclear Information System (INIS)

    Arteconi, A; Giuliani, G; Tartuferi, M; Polonara, F

    2014-01-01

    In this paper a mini-channel aluminum heat exchanger used in a reversible heat pump is presented. Mini-channel finned heat exchangers are getting more and more interest for refrigeration systems, especially when compactness and low refrigerant charge are desired. Purpose of this paper was to characterize the mini-channel heat exchanger used as evaporator in terms of heat transfer performance and to study the refrigerant distribution in the manifold. The heat exchanger characterization was performed experimentally by means of a test rig built up for this purpose. It is composed of an air-to-air heat pump, air channels for the external and internal air circulation arranged in a closed loop, measurement sensors and an acquisition system. The overall heat transfer capacity was assessed. Moreover, in order to characterize the flow field of the refrigerant in the manifold of the heat exchanger, a numerical investigation of the fluid flow by means of CFD was performed. It was meant to evaluate the goodness of the present design and to identify possible solutions for the future improvement of the manifold design.

  1. Enhancing Application Performance Using Mini-Apps: Comparison of Hybrid Parallel Programming Paradigms

    Science.gov (United States)

    Lawson, Gary; Sosonkina, Masha; Baurle, Robert; Hammond, Dana

    2017-01-01

    In many fields, real-world applications for High Performance Computing have already been developed. For these applications to stay up-to-date, new parallel strategies must be explored to yield the best performance; however, restructuring or modifying a real-world application may be daunting depending on the size of the code. In this case, a mini-app may be employed to quickly explore such options without modifying the entire code. In this work, several mini-apps have been created to enhance a real-world application performance, namely the VULCAN code for complex flow analysis developed at the NASA Langley Research Center. These mini-apps explore hybrid parallel programming paradigms with Message Passing Interface (MPI) for distributed memory access and either Shared MPI (SMPI) or OpenMP for shared memory accesses. Performance testing shows that MPI+SMPI yields the best execution performance, while requiring the largest number of code changes. A maximum speedup of 23 was measured for MPI+SMPI, but only 11 was measured for MPI+OpenMP.

  2. Laser-Driven Mini-Thrusters

    International Nuclear Information System (INIS)

    Sterling, Enrique; Lin Jun; Sinko, John; Kodgis, Lisa; Porter, Simon; Pakhomov, Andrew V.; Larson, C. William; Mead, Franklin B. Jr.

    2006-01-01

    Laser-driven mini-thrusters were studied using Delrin registered and PVC (Delrin registered is a registered trademark of DuPont) as propellants. TEA CO2 laser (λ = 10.6 μm) was used as a driving laser. Coupling coefficients were deduced from two independent techniques: force-time curves measured with a piezoelectric sensor and ballistic pendulum. Time-resolved ICCD images of the expanding plasma and combustion products were analyzed in order to determine the main process that generates the thrust. The measurements were also performed in a nitrogen atmosphere in order to test the combustion effects on thrust. A pinhole transmission experiment was performed for the study of the cut-off time when the ablation/air breakdown plasma becomes opaque to the incoming laser pulse

  3. Laser-Driven Mini-Thrusters

    Science.gov (United States)

    Sterling, Enrique; Lin, Jun; Sinko, John; Kodgis, Lisa; Porter, Simon; Pakhomov, Andrew V.; Larson, C. William; Mead, Franklin B.

    2006-05-01

    Laser-driven mini-thrusters were studied using Delrin® and PVC (Delrin® is a registered trademark of DuPont) as propellants. TEA CO2 laser (λ = 10.6 μm) was used as a driving laser. Coupling coefficients were deduced from two independent techniques: force-time curves measured with a piezoelectric sensor and ballistic pendulum. Time-resolved ICCD images of the expanding plasma and combustion products were analyzed in order to determine the main process that generates the thrust. The measurements were also performed in a nitrogen atmosphere in order to test the combustion effects on thrust. A pinhole transmission experiment was performed for the study of the cut-off time when the ablation/air breakdown plasma becomes opaque to the incoming laser pulse.

  4. Usefulness of the Mini Nutritional Assessment (MNA) in predicting the nutritional status of people with mental disorders in Taiwan.

    Science.gov (United States)

    Tsai, Alan C; Chou, Yuan-Ti; Chang, Tsui-Lan

    2011-02-01

    The study was to evaluate the ability of the Mini Nutritional Assessment in predicting malnutrition in people with three subtypes of mental disorder (schizophrenia, major depression and bipolar disorder) in Taiwan. The study involved a convenience sample of 120 residents of psychiatric wards managed by a hospital in central Taiwan (52 with schizophrenia, 36 with major depression and 32 with bipolar disorder) classified according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition criteria. A structured questionnaire elicited subjects' personal data, disease history and answers to questions in the Mini Nutritional Assessment. Serum and anthropometrical parameters were measured. Nutritional status was evaluated with a content-equivalent version of the Mini Nutritional Assessment (Taiwan version-1, T1). The Mini Nutritional Assessment-Taiwan version-1 was effective in assessing the nutritional status of people of all three subtypes of disorder. Nutritional statuses predicted with the Mini Nutritional Assessment-Taiwan version-1 agreed well with other nutritional indicators such as BMI, waist circumference and appetite status. According to the Mini Nutritional Assessment-Taiwan version-1, people with major depression were more likely to be at risk of undernutrition, whereas people with schizophrenia or bipolar disorder were more likely to be at risk of overnutrition. The Mini Nutritional Assessment-Taiwan version-1 can effectively grade both undernutrition and overnutrition of people with schizophrenia, major depression or bipolar disorder. The Mini Nutritional Assessment enables nurses to monitor emerging nutritional problems in people with psychiatric disorder without relying on subjective judgement. With proper intervention, it can help reduce nutrition-related chronic conditions in these individuals and save on healthcare cost. © 2011 Blackwell Publishing Ltd.

  5. Toward Solution of the MiniBooNE-LSND Anomalies

    International Nuclear Information System (INIS)

    Karagiorgi, G.

    2012-01-01

    The LSND experiment has observed an anomalous excess of ν ¯ e events in a ν ¯ μ beam which can be interpreted as two-neutrino ν ¯ μ →ν ¯ e oscillations at Δm 2 ∼1 eV 2 , suggesting new physics. The MiniBooNE experiment has ruled out the LSND two-neutrino oscillation interpretation by looking for corresponding flavor oscillations in a neutrino beam, and assuming CP and CPT conservation. However, it has observed an anomalous excess of ν e events at low energy, which, to date, remains unexplained. The two excess signatures are discussed within the context of light sterile neutrino oscillations, and are further confronted with the latest results from a MiniBooNE search for ν ¯ μ →ν ¯ e oscillations in an antineutrino beam. Alternative interpretations are also referenced, along with possible future experimental tests.

  6. Avaliação do torque para inserção, remoção e fratura de diferentes mini-implantes ortodônticos Evaluation of insertion, removal and fracture torques of different orthodontic mini-implants in bovine tibia cortex

    Directory of Open Access Journals (Sweden)

    Maria Fernanda Prates da Nova

    2008-10-01

    Full Text Available OBJETIVO: avaliar, em mini-implantes de diferentes dimensões, os seguintes fatores: (a torque de inserção, (b torque de remoção, (c torque de fratura, (d tensão cisalhante, (e tensão normal e (f tipo de fratura. METODOLOGIA: foram utilizados 20 mini-implantes autoperfurantes, 10 da marca SIN e 10 da Neodent com, respectivamente, 8 e 7mm de comprimento, todos com 1,6mm de diâmetro. Dos 10 mini-implantes de cada marca, 5 não possuíam perfil transmucoso e 5 tinham perfil de 2mm, formando 4 grupos: SIN sem perfil (SSP, SIN com perfil (SCP, Neodent sem perfil (NSP e Neodent com perfil (NCP. Todos os mini-implantes foram inseridos em cortical óssea e removidos com micromotor acoplado a um torquímetro. Os mini-implantes foram, também, submetidos ao ensaio de fratura. Os torques de inserção, remoção e fratura, assim como a tensão cisalhante e normal calculadas, foram comparados entre todos os grupos pela ANOVA. O tipo de fratura foi avaliado em microscópio eletrônico de varredura. RESULTADOS: verificou-se que o grupo NCP apresentou torque de inserção significativamente maior que os demais grupos, porém todos fraturaram durante a inserção (n = 2 ou remoção (n = 3. Não houve diferença entre os grupos para o torque de remoção. Para o grupo NSP, o torque de fratura foi significativamente menor do que todos os outros grupos. Todos os mini-implantes sofreram fratura do tipo dúctil. CONCLUSÃO: uma vez que não houve diferença na resistência mecânica de ambas as marcas, variando apenas a forma, conclui-se que a resistência à fratura pode ser afetada por esta variável.AIM: The purpose of this study was to evaluate mini-implants with different dimensions for the following factors: (a insertion torque, (b removal torque, (c fracture torque, (d shear tension, (e normal tension and (f type of fracture. METHODS: Twenty self-drilling mini-implants were used, 10 from SIN and 10 from Neodent, with 1.6mm in diameter and with 8 and 7

  7. MiniSipper: a new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring.

    Science.gov (United States)

    Chapin, Thomas P; Todd, Andrew S

    2012-11-15

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7-8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R(2)>0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed. Published by Elsevier B.V.

  8. MiniSipper: A new in situ water sampler for high-resolution, long-duration acid mine drainage monitoring

    Science.gov (United States)

    Chapin, Thomas P.; Todd, Andrew S.

    2012-01-01

    Abandoned hard-rock mines can be a significant source of acid mine drainage (AMD) and toxic metal pollution to watersheds. In Colorado, USA, abandoned mines are often located in remote, high elevation areas that are snowbound for 7–8 months of the year. The difficulty in accessing these remote sites, especially during winter, creates challenging water sampling problems and major hydrologic and toxic metal loading events are often under sampled. Currently available automated water samplers are not well suited for sampling remote snowbound areas so the U.S. Geological Survey (USGS) has developed a new water sampler, the MiniSipper, to provide long-duration, high-resolution water sampling in remote areas. The MiniSipper is a small, portable sampler that uses gas bubbles to separate up to 250 five milliliter acidified samples in a long tubing coil. The MiniSipper operates for over 8 months unattended in water under snow/ice, reduces field work costs, and greatly increases sampling resolution, especially during inaccessible times. MiniSippers were deployed in support of an U.S. Environmental Protection Agency (EPA) project evaluating acid mine drainage inputs from the Pennsylvania Mine to the Snake River watershed in Summit County, CO, USA. MiniSipper metal results agree within 10% of EPA-USGS hand collected grab sample results. Our high-resolution results reveal very strong correlations (R2 > 0.9) between potentially toxic metals (Cd, Cu, and Zn) and specific conductivity at the Pennsylvania Mine site. The large number of samples collected by the MiniSipper over the entire water year provides a detailed look at the effects of major hydrologic events such as snowmelt runoff and rainstorms on metal loading from the Pennsylvania Mine. MiniSipper results will help guide EPA sampling strategy and remediation efforts in the Snake River watershed.

  9. [Comparison of endotracheal aspiration and mini-BAL culture results in the diagnosis of ventilator-associated pneumonia].

    Science.gov (United States)

    Artuk, Cumhur; Gül, Hanefi Cem; Mert, Gürkan; Karakaş, Ahmet; Bedir, Orhan; Eyigün, Can Polat

    2012-07-01

    The objective of this study was to compare the results of cultures obtained by mini-bronchoalveolar lavage (BAL) and endotracheal aspiration (ETA) techniques, used for rapid and accurate determination of pathogens causing ventilator-associated pneumonia (VAP) in intensive care units. Of the 92 patients on mechanical ventilation followed at the emergency intensive care unit of our hospital between June 2010 and June 2011, 30 (32.2%) patients were diagnosed as VAP and they were included in this study. VAP diagnosis were based on the clinical and radiological findings. Clinical pulmonary infection score (CPIS) of > 6 was accepted as the clinical criteria of VAP. Initially ETA samples were collected from the patients followed by mini-BAL sampling 15 minutes later, together with urine and two blood cultures. Microbiological evaluation and identification were performed by conventional methods and Phoenix 100 (BD Diagnostic Systems, ABD) automated system. In quantitative culture analysis, > 10.000 cfu/ml for BAL and > 100.000 cfu/ml for ETA were accepted as the positive result. The mean ages of VAP-developed (n= 30; 18 were male) and nondeveloped (n= 62; 39 were male) patients were 68.23 ± 16.19 and 52.16 ± 10.41 years, respectively, and the mean durations of mechanical ventilation were 29.57 ± 15.78 and 12.11 ± 6.01 days, respectively. Multivariate logistic regression analysis showed that older age (pVAP development. There was also a statistically significant difference in CPIS values between patients who developed VAP and not (6.8 ± 1.15 and 2.71 ± 1.06, respectively; pVAP diagnosis was found to be useful in patients on mechanical ventilation. In our study, a total of 16 strains (six A.baumannii, three P.aeruginosa, one K.pneumoniae, six S.aureus) were isolated from ETA cultures, while 34 strains (16 A.baumannii, six P.aeruginosa, four K.pneumoniae, two E.coli, six S.aureus) were isolated from mini-BAL cultures of 30 VAP patients. The contamination rate for ETA

  10. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  11. The ASTRI mini-array within the future Cherenkov Telescope Array

    Directory of Open Access Journals (Sweden)

    Vercellone Stefano

    2016-01-01

    Full Text Available The Cherenkov Telescope Array (CTA is a large collaborative effort aimed at the design and operation of an observatory dedicated to very high-energy gamma-ray astrophysics in the energy range from a few tens of GeV to above 100 TeV, which will yield about an order of magnitude improvement in sensitivity with respect to the current major arrays (H.E.S.S., MAGIC, and VERITAS. Within this framework, the Italian National Institute for Astrophysics is leading the ASTRI project, whose main goals are the design and installation on Mt. Etna (Sicily of an end-to-end dual-mirror prototype of the CTA small size telescope (SST and the installation at the CTA Southern site of a dual-mirror SST mini-array composed of nine units with a relative distance of about 300 m. The innovative dual-mirror Schwarzschild-Couder optical solution adopted for the ASTRI Project allows us to substantially reduce the telescope plate-scale and, therefore, to adopt silicon photo-multipliers as light detectors. The ASTRI mini-array is a wider international effort. The mini-array, sensitive in the energy range 1–100 TeV and beyond with an angular resolution of a few arcmin and an energy resolution of about 10–15%, is well suited to study relatively bright sources (a few × 10−12 erg cm−2 s−1 at 10 TeV at very high energy. Prominent sources such as extreme blazars, nearby well-known BL Lac objects, Galactic pulsar wind nebulae, supernovae remnants, micro-quasars, and the Galactic Center can be observed in a previously unexplored energy range. The ASTRI mini-array will extend the current IACTs sensitivity well above a few tens of TeV and, at the same time, will allow us to compare our results on a few selected targets with those of current (HAWC and future high-altitude extensive air-shower detectors.

  12. Tests of Lorentz and CPT violation with MiniBooNE neutrino oscillation excesses

    International Nuclear Information System (INIS)

    Katori, Teppei

    2014-01-01

    Lorentz and CPT symmetry violaton is a predicted phenomenon of Planck–scale physics. Various types of data are analyzed to search for Lorentz violation under the Standard–Model Extension (SME) framework, including neutrino oscillation data. MiniBooNE is a short–baseline neutrino oscillation experiment at Fermilab. The measured excesses from MiniBooNE cannot be reconciled within the neutrino Standard Model (vSM); thus it might be a signal of new physics, such as Lorentz violation. We have analyzed the sidereal time dependence of MiniBooNE data for signals of the possible sidereal time dependence of the ocillation signals. we find that the v e appearance data prefer a sidereal time–independent solution, and the v-bar e appearance data slightly prefer a sidereal time–dependent solution, however, the statistical significance is not high to claim the discovery. Limits of order 10 −20 GeV are placed on combinations of SME coefficients

  13. Mapping of radiation anomalies using UAV mini-airborne gamma-ray spectrometry.

    Science.gov (United States)

    Šálek, Ondřej; Matolín, Milan; Gryc, Lubomír

    2018-02-01

    Localization of size-limited gamma-ray anomalies plays a fundamental role in uranium prospecting and environmental studies. Possibilities of a newly developed mini-airborne gamma-ray spectrometric equipment were tested on a uranium anomaly near the village of Třebsko, Czech Republic. The measurement equipment was based on a scintillation gamma-ray spectrometer specially developed for unmanned aerial vehicles (UAV) mounted on powerful hexacopter. The gamma-ray spectrometer has two 103 cm 3 BGO scintillation detectors of relatively high sensitivity. The tested anomaly, which is 80 m by 40 m in size, was investigated by ground gamma-ray spectrometric measurement in a detail rectangular measurement grid. Average uranium concentration is 25 mg/kg eU attaining 700 mg/kg eU locally. The mini-airborne measurement across the anomaly was carried out on three 100 m long parallel profiles at eight flight altitudes from 5 to 40 m above the ground. The resulting 1 s 1024 channel gamma-ray spectra, recorded in counts per second (cps), were processed to concentration units of K, U and Th, while total count (TC) was reported in cps. Increased gamma ray intensity of the anomaly was indicated by mini-airborne measurement at all profiles and altitudes, including the highest altitude of 40 m, at which the recorded intensity is close to the natural radiation background. The reported instrument is able to record data with comparable quality as standard airborne survey, due to relative sensitive detector, lower flight altitude and relatively low flight speed of 1 m/s. The presented experiment brings new experience with using unmanned semi-autonomous aerial vehicles and the latest mini-airborne radiometric instrument. The experiment has demonstrated the instrument's ability to localize size-limited uranium anomalies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Alzheimer's Dementia: Performance on the Mini-Mental State Examination.

    Science.gov (United States)

    Teng, Evelyn Lee; And Others

    1987-01-01

    Analyzed the performance of Alzheimer's patients (N=141) on the Mini-Mental State Examination. Performance on all items showed significant negative correlation with the duration of the illness. The most difficult item was "recall," and the improvement in recall was obtained with cuing. (Author/ABB)

  15. Two-stage SQUID systems and transducers development for MiniGRAIL

    International Nuclear Information System (INIS)

    Gottardi, L; Podt, M; Bassan, M; Flokstra, J; Karbalai-Sadegh, A; Minenkov, Y; Reinke, W; Shumack, A; Srinivas, S; Waard, A de; Frossati, G

    2004-01-01

    We present measurements on a two-stage SQUID system based on a dc-SQUID as a sensor and a DROS as an amplifier. We measured the intrinsic noise of the dc-SQUID at 4.2 K. A new dc-SQUID has been fabricated. It was specially designed to be used with MiniGRAIL transducers. Cooling fins have been added in order to improve the cooling of the SQUID and the design is optimized to achieve the quantum limit of the sensor SQUID at temperatures above 100 mK. In this paper we also report the effect of the deposition of a Nb film on the quality factor of a small mass Al5056 resonator. Finally, the results of Q-factor measurements on a capacitive transducer for the current MiniGRAIL run are presented

  16. Water droplet accumulation and motion in PEM (Proton Exchange Membrane) fuel cell mini-channels

    International Nuclear Information System (INIS)

    Carton, J.G.; Lawlor, V.; Olabi, A.G.; Hochenauer, C.; Zauner, G.

    2012-01-01

    Effective water management is one of the key strategies for improving low temperature PEM (Proton Exchange Membrane) fuel cell performance and durability. Phenomena such as membrane dehydration, catalyst layer flooding, mass transport and fluid flow regimes can be affected by the interaction, distribution and movement of water in flow plate channels. In this paper a literature review is completed in relation to PEM fuel cell water flooding. It is clear that droplet formation, movement and interaction with the GDL (Gas Diffusion Layer) have been studied extensively. However slug formation and droplet accumulation in the flow channels has not been analysed in detail. In this study, a CFD (Computational Fluid Dynamic) model and VOF (Volume of Fluid) method is used to simulate water droplet movement and slug formation in PEM fuel cell mini-channels. In addition, water slug visualisation is recorded in ex situ PEM fuel cell mini-channels. Observation and simulation results are discussed with relation to slug formation and the implications to PEM fuel cell performance. -- Highlights: ► Excess water in mini-channels from the collision and coalescence of droplets can directly form slugs in PEM fuel cells. ► Slugs can form at low flow rates so increasing the flow rate can reduce the size and frequency of slugs. ► One channel of a double serpentine mini-channel may become blocked due to the redistribution of airflow and pressure caused by slug formation. ► Correct GDL and mini-channel surface coatings are essential to reduce slug formation and stagnation. ► Having geometry changes (bends and steps) in the flow fields can disrupt slug movement and avoid channel blockages.

  17. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    Science.gov (United States)

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  18. RESPON LINGKUNGAN BELANJA SEBAGAI STIMULUS PEMBELIAN TIDAK BERENCANA PADA MINI MARKET MAMI MART PAINAN

    Directory of Open Access Journals (Sweden)

    Mareta Kemala Sari

    2014-10-01

    Full Text Available Research planning not purchase the mami mini market mart visits from customer response to environmental spending as a stimulus, a customer case study on mini market mart mom Painan. Research using response variables shopping environment consisting of Pleasure, Arousal, Dominance.as mediator variable, hedonic shopping value, utilitarian shopping value, resources expenditure on the purchase was not planned (Impulse Buying. Data were collected using questionnaires distributed during the 2 weeks to the respondents who never shop at mini market. The study population is that they all are a mini market mami mart customers aged 18-55 years and have never shopped with a minimum of 2 times the transaction, the methods used by the descriptive analysis, and processing research model with smartPLS program. Mengunggapkan research results that the response variable dominance shopping environment positive effect on resources expenditure. Shopping environment arousal response variable positive effect on resources expenditure. Also revealed that spending resources poengalaman variable expenditure not a mediator between the response variable shopping environment and other variables shopping experience, as well as the negative effect on the purchase was not planned. But the expenditure of resources affect the shopping experience more variables such as the hedonic shopping value, utilitarian shopping value, resources expenditure

  19. Deconstructing the concept of renewable energy-based mini-grids for rural electrification in East Africa

    DEFF Research Database (Denmark)

    Pedersen, Mathilde Brix

    2016-01-01

    The goal of providing universal energy access to all by 2030 under the UN-led SE4ALL initiative calls for new and innovative solutions to rural electrification and is fuelling the recent interest in mini-grids. Mini-grid solutions are emerging as a third alternative to rural electrification, coming...... between the option of large-scale grid extension and pico-scale stand-alone solutions like solar home systems or solar lanterns. International expectations of mini-grids are high, with the International Energy Agency suggesting that they will play a significant role in reaching the goal of universal...... electrification and the challenges identified in the literature, the study concludes by proposing three avenues for further research. For further resources related to this article, please visit the WIREs website....

  20. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    Science.gov (United States)

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in

  1. Economics of Mini tuber Seed Yam Production Technique in South ...

    African Journals Online (AJOL)

    Marcel

    Socio-economic studies on yam production conducted in Nigeria include Lageman (1977) .... the profitability of the mini tuber seed yam production technique as a guide .... production (with particular reference to Root Crops in the West Indies).

  2. Teach yourself visually Mac Mini

    CERN Document Server

    Hart-Davis, Guy

    2012-01-01

    The perfect how-to guide for visual learners Apple?s Mac Mini packs a powerful punch is in a small package, including both HDMI and Thunderbolt ports plus the acclaimed OS X. But if you want to get the very most from all this power and versatility, be sure to get this practical visual guide. With full-color, step-by-step instructions as well as screenshots and illustrations on every page, it clearly shows you how to accomplish tasks rather than burying you in pages of text. Discover helpful visuals and how-tos on the OS, hardware specs, Launchpad, the App Store, multimedia capabilities (such

  3. Functional Movements in Japanese Mini-Basketball Players

    Directory of Open Access Journals (Sweden)

    Kuzuhara Kenji

    2018-03-01

    Full Text Available Functional movement screen (FMS has been used to establish normative data and determine potential injury risk for young adults and athletes, but there are few data in elementary school-age children. The purpose of this study was to establish fundamental values for the FMS in elementary school-age mini-basketball players. Secondary purposes were to examine relationships between functional movement patterns and age, peak height velocity (PHV, and body mass index (BMI, and to compare functional movement patterns between boys and girls and between individuals with and without a history of injury. The mean composite FMS score was 16.5 ± 2.2 (16.5 ± 2.4 for boys, 16.5 ± 1.7 for girls. The composite FMS score was positively correlated with age (r = .312 and negatively correlated with the BMI (r = − .371. However, the FMS score was not correlated with PHV or with PHV age. The FMS score was not different between boys and girls or between individuals who reported a previous injury and those who did not. However, boys in the mini-basketball teams performed better than girls on the trunk stability push-up and rotary stability tests. Age and the body mass index were significantly associated with better and poorer functional movement, respectively.

  4. Could mini black holes provide a 'theory of everything'?

    CERN Multimedia

    Gribbin, J

    1990-01-01

    A Soviet astrophysicist is claiming that the Earth and other astronomical bodies may be riddled with mini black holes - objects smaller than atoms but with masses perhaps greater than planets. These could be responsible for a variety of phenomena inc the rings of Saturn (1/2 page).

  5. Mini-Digest of Education Statistics, 2010. NCES 2011-016

    Science.gov (United States)

    Snyder, Thomas D.

    2011-01-01

    This pocket-sized compilation of statistical information covers prekindergarten through graduate school to describe the current American education scene. The "Mini-Digest" is designed as an easy reference for materials found in detail in the "Digest of Education Statistics". These volumes include selections of data from many…

  6. Mini-Digest of Education Statistics, 2009. NCES 2010-014

    Science.gov (United States)

    Snyder, Thomas D.

    2010-01-01

    This compilation of statistical information covers prekindergarten through graduate school to describe the current American education scene. The "Mini-Digest" is designed as an easy reference for materials found in detail in the "Digest of Education Statistics, 2009". These volumes include selections of data from many…

  7. Embedding Hands-On Mini Laboratory Experiences in a Core Undergraduate Fluid Mechanics Course: A Pilot Study

    Science.gov (United States)

    Han, Duanduan; Ugaz, Victor

    2017-01-01

    Three self-contained mini-labs were integrated into a core undergraduate fluid mechanics course, with the goal of delivering hands-on content in a manner scalable to large class sizes. These mini-labs supported learning objectives involving friction loss in pipes, flow measurement, and centrifugal pump analysis. The hands-on experiments were…

  8. Mini-beam collimator applications at the Advanced Photon Source

    Energy Technology Data Exchange (ETDEWEB)

    Xu Shenglan, E-mail: sxu@anl.gov [GM/CA CAT, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Keefe, Lisa J.; Mulichak, Anne [IMCA CAT, Argonne National Laboratory, Argonne, IL 60439 (United States); Yan Lifen; Alp, Ercan E.; Zhao Jiyong [X-ray Sciences Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Fischetti, Robert F. [GM/CA CAT, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2011-09-01

    In 2007, the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA CAT, Sector 23, Advanced Photon Source) began providing mini-beam collimators to its users. These collimators contained individual, 5- or 10-{mu}m pinholes and were rapidly exchangeable, thereby allowing users to tailor the beam size to their experimental needs. The use of these collimators provided a reduction in background noise, and thus improved the signal-to-noise ratio . Recent improvements in the collimator design include construction of the device from a monolithic piece of molybdenum with multiple pinholes mounted inside . This allows users to select from various size options from within the beamline control software without the realignment that was previously necessary. In addition, a new, 20-{mu}m pinhole has been added to create a 'quad-collimator', resulting in greater flexibility for the users. The mini-beam collimator is now available at multiple crystallographic beamlines and also is a part of the first Moessbauer Microscopic system at sector 3-ID.

  9. Mini-beam collimator applications at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Xu Shenglan; Keefe, Lisa J.; Mulichak, Anne; Yan Lifen; Alp, Ercan E.; Zhao Jiyong; Fischetti, Robert F.

    2011-01-01

    In 2007, the General Medicine and Cancer Institutes Collaborative Access Team (GM/CA CAT, Sector 23, Advanced Photon Source) began providing mini-beam collimators to its users. These collimators contained individual, 5- or 10-μm pinholes and were rapidly exchangeable, thereby allowing users to tailor the beam size to their experimental needs. The use of these collimators provided a reduction in background noise, and thus improved the signal-to-noise ratio . Recent improvements in the collimator design include construction of the device from a monolithic piece of molybdenum with multiple pinholes mounted inside . This allows users to select from various size options from within the beamline control software without the realignment that was previously necessary. In addition, a new, 20-μm pinhole has been added to create a 'quad-collimator', resulting in greater flexibility for the users. The mini-beam collimator is now available at multiple crystallographic beamlines and also is a part of the first Moessbauer Microscopic system at sector 3-ID.

  10. Searches for New Physics at MiniBooNE: Sterile Neutrinos and Mixing Freedom

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgi, Georgia S. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2010-09-01

    The MiniBooNE experiment was designed to perform a search for vμ → ve oscillations in a region of Δm2 and sin2 2θ very different from that allowed by standard, three-neutrino oscillations, as determined by solar and atmospheric neutrino experiments. This search was motivated by the LSND experimental observation of an excess of $\\bar{v}$e events in a $\\bar{v}$μ beam which was found compatible with two-neutrino oscillations at Δm2 ~ 1 eV2 and sin2 2{theta} < 1%. If confirmed, such oscillation signature could be attributed to the existence of a light, mostly-sterile neutrino, containing small admixtures of weak neutrino eigenstates. In addition to a search for vμ → ve oscillations, MiniBooNE has also performed a search for vμ → ve oscillations, which provides a test of the LSND two-neutrino oscillation interpretation that is independent of CP or CPT violation assumptions. This dissertation presents the MiniBooNE vμ → ve and vμ → ve analyses and results, with emphasis on the latter. While the neutrino search excludes the two-neutrino oscillation interpretation of LSND at 98% C.L., the antineutrino search shows an excess of events which is in agreement with the two-neutrino vμ → ve oscillation interpretation of LSND, and excludes the no oscillations hypothesis at 96% C.L. Even though the neutrino and antineutrino oscillation results from MiniBooNE disagree under the single sterile neutrino oscillation hypothesis, a simple extension to the model to include additional sterile neutrino states and the possibility of CP violation allows for differences between neutrino and antineutrino oscillation signatures. In view of that, the viability of oscillation models with one or two sterile neutrinos is investigated in global fits to MiniBooNE and LSND

  11. Detection of X-ray spectral state transitions in mini-outbursts of black hole transient GRS 1739-278

    Science.gov (United States)

    Yan, Zhen; Yu, Wenfei

    2017-10-01

    We report the detection of the state transitions and hysteresis effect in the two mini-outbursts of the black hole (BH) transient GRS 1739-278 following its 2014 major outburst. The X-ray spectral evolutions in these two mini-outbursts are similar to the major outburst in spite of their peak luminosities and the outburst durations are one order of magnitude lower. We found L_hard{-to-soft} and Lpeak,soft of the mini-outbursts also follow the correlation previously found in other X-ray binaries. L_hard{-to-soft} of the mini-outbursts is still higher than that of the persistent BH binary Cyg X-1, which supports that there is a link between the maximum luminosity a source can reach in the hard state and the corresponding non-stationary accretion represented by substantial rate of change in the mass accretion rate during flares/outbursts. The detected luminosity range of these two mini-outbursts is roughly in 3.5 × 10-5 to 0.015 (D/7.5 kpc)2(M/8M⊙) LEdd. The X-ray spectra of other BH transients at such low luminosities are usually dominated by a power-law component, and an anti-correlation is observed between the photon index and the X-ray luminosity below 1 per cent LEdd. So, the detection of X-ray spectral state transitions indicates that the accretion flow evolution in these two mini-outbursts of GRS 1739-278 are different from other BH systems at such low-luminosity regime.

  12. Ability of mini-implant-facilitated micro-osteoperforations to accelerate tooth movement in rats.

    Science.gov (United States)

    Cheung, Tracy; Park, Juyoung; Lee, Deborah; Kim, Catherine; Olson, Jeffrey; Javadi, Shadi; Lawson, Gregory; McCabe, James; Moon, Won; Ting, Kang; Hong, Christine

    2016-12-01

    Although current techniques for accelerated tooth movement often involve invasive surgical procedures, micro-osteoperforations (MOPs) using mini-implants may facilitate orthodontic tooth movement without raising flaps, reduce surgical risks, and increase patient acceptance. In this study, we evaluated the effectiveness of mini-implant-facilitated MOPs in inducing accelerated tooth movement and investigated the potential risks for root resorption. Five MOPs were placed on the left side around the maxillary first molars in 6 rats using an automated mini-implant driver, whereas the right side received no MOPs as the control. Closed-coiled springs were secured from incisors to first molars for orthodontic tooth movement. Tooth movement was measured, and samples underwent radiologic and histologic analyses. The MOP side exhibited a 1.86-fold increase in the rate of tooth movement with decreased bone density and bone volume around the first molars compared with the control side. Hematoxylin and eosin and tartrate-resistant acid phosphatase analyses showed increased numbers of osteoclasts as well as new bone formation. Three-dimensional volumetric analysis of all 5 roots of the maxillary first molars demonstrated no statistically significant difference in root volumes. Mini-implant-facilitated MOPs accelerated tooth movement without increased risk for root resorption and therefore may become a readily available and efficient treatment option to shorten orthodontic treatment time with improved patient acceptance. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Journals Abroad

    Science.gov (United States)

    Ando, Shoichi

    1975-01-01

    This article summarizes four journal articles on language teaching appearing in the American pedagogical language journals, "The Modern Language Journal,""English Language Teaching Journal," and "TESOL Quarterly." The purpose is to give an indication of what kinds of articles can be found in journals outside Japan.…

  14. Journal Management

    African Journals Online (AJOL)

    The Journal Manager sees to all aspects of Journal Management, in consultation with the Editors, including setting up and configuring the journal system, enrolling users in the various roles needed to run the journal, setting up the various Sections of the journal, and many other managerial tasks.

  15. Er:YAG laser, piezosurgery, and surgical drill for bone decortication during orthodontic mini-implant insertion: primary stability analysis-an animal study.

    Science.gov (United States)

    Matys, Jacek; Flieger, Rafał; Tenore, Gianluca; Grzech-Leśniak, Kinga; Romeo, Umberto; Dominiak, Marzena

    2018-04-01

    It is important to identify factors that affect primary stability of orthodontic mini-implants because it determines the success of treatment. We assessed mini-implant primary stability (initial mechanical engagement with the bone) placed in pig jaws. We also assessed mini-implant insertion failure rate (mini-implant fracture, mini-implants to root contact). A total of 80 taper-shaped mini-implants (Absoanchor® Model SH1312-6; Dentos Inc., Daegu, Korea) 6 mm long with a diameter of 1.1 mm were used. Bone decortication was made before mini-implant insertion by means of three different methods: Group G1: Er:YAG laser (LiteTouch®, Light Instruments, Yokneam, Israel) at energy of 300 mJ, frequency 25 Hz, fluence 38.2 J/cm2, cooling 14 ml/min, tip 1.0 × 17 mm, distance 1 mm, time of irradiation 6 s; Group G2: drill (Hager & Meisinger GmbH, Hansemannstr, Germany); Group G3: piezosurgery (Piezotom Solo, Acteon, NJ, USA). In G4 group (control), mini-implants were driven by a self-drilling method. The primary stability of mini-implants was assessed by measuring damping characteristics between the implant and the tapping head of Periotest device (Gulden-Medizinteknik, Eschenweg, Modautal, Germany). The results in range between - 8 to + 9 allowed immediate loading. Significantly lower Periotest value was found in the control group (mean 0.59 ± 1.57, 95% CI 0.7, 2.4) as compared with Er:YAG laser (mean 4.44 ± 1.64, 95% CI 3.6, 5.3), piezosurgery (mean 17.92 ± 2.73, 95% CI 16.5, 19.3), and a drill (mean 5.91 ± 1.52, 95% CI 5.2, 6.6) (p piezosurgery. Decortication of the cortical bone before mini-implant insertion resulted in reduced risk of implant fracture or injury of adjacent teeth. The high initial stability with a smaller diameter of the mini-implant resulted in increased risk of fracture, especially for a self-drilling method.

  16. A 7 µm mini-beam improves diffraction data from small or imperfect crystals of macromolecules

    International Nuclear Information System (INIS)

    Sanishvili, Ruslan; Nagarajan, Venugopalan; Yoder, Derek; Becker, Michael; Xu, Shenglan; Corcoran, Stephen; Akey, David L.; Smith, Janet L.; Fischetti, Robert F.

    2008-01-01

    An X-ray mini-beam of 8 × 6 µm cross-section was used to collect diffraction data from protein microcrystals with volumes as small as 150–300 µm 3 . The benefits of the mini-beam for experiments with small crystals and with large inhomogeneous crystals are investigated. A simple apparatus for achieving beam sizes in the range 5-10 µm on a synchrotron beamline was implemented in combination with a small 125 × 25 µm focus. The resulting beam had sufficient flux for crystallographic data collection from samples smaller than 10 × 10 × 10 µm. Sample data were collected representing three different scenarios: (i) a complete 2.0 Å data set from a single strongly diffracting microcrystal, (ii) a complete and redundant 1.94 Å data set obtained by merging data from six microcrystals and (iii) a complete 2.24 Å data set from a needle-shaped crystal with less than 12 × 10 µm cross-section and average diffracting power. The resulting data were of high quality, leading to well refined structures with good electron-density maps. The signal-to-noise ratios for data collected from small crystals with the mini-beam were significantly higher than for equivalent data collected from the same crystal with a 125 × 25 µm beam. Relative to this large beam, use of the mini-beam also resulted in lower refined crystal mosaicities. The mini-beam proved to be advantageous for inhomogeneous large crystals, where better ordered regions could be selected by the smaller beam

  17. User of ordered mixtures to obtain high dose homogeneity in mini-tablets : studies of orally disintegrating systems for children

    OpenAIRE

    Løding, Fredrik Sandberg

    2011-01-01

    Studies have shown that homogeneity is higher in ordered mixtures compared to random mixtures. Based on this ordered mixtures should be particularly suitable for the preparation of mini-tablets. The overall aim of the study was to compare the homogeneity of ordered mixtures prepared using different particle size of carrier particles, and test their suitability for preparation of mini-tablets. The mini-tablets are intended for use as orally disintegrating systems (ODT) for children...

  18. Reliability, validity and minimal detectable change of the Mini-BESTest in Greek participants with chronic stroke.

    Science.gov (United States)

    Lampropoulou, Sofia I; Billis, Evdokia; Gedikoglou, Ingrid A; Michailidou, Christina; Nowicky, Alexander V; Skrinou, Dimitra; Michailidi, Fotini; Chandrinou, Danae; Meligkoni, Margarita

    2018-02-23

    This study aimed to investigate the psychometric characteristics of reliability, validity and ability to detect change of a newly developed balance assessment tool, the Mini-BESTest, in Greek patients with stroke. A prospective, observational design study with test-retest measures was conducted. A convenience sample of 21 Greek patients with chronic stroke (14 male, 7 female; age of 63 ± 16 years) was recruited. Two independent examiners administered the scale, for the inter-rater reliability, twice within 10 days for the test-retest reliability. Bland Altman Analysis for repeated measures assessed the absolute reliability and the Standard Error of Measurement (SEM) and the Minimum Detectable Change at 95% confidence interval (MDC 95% ) were established. The Greek Mini-BESTest (Mini-BESTest GR ) was correlated with the Greek Berg Balance Scale (BBS GR ) for assessing the concurrent validity and with the Timed Up and Go (TUG), the Functional Reach Test (FRT) and the Greek Falls Efficacy Scale-International (FES-I GR ) for the convergent validity. The Mini-BESTestGR demonstrated excellent inter-rater reliability (ICC (95%CI) = 0.997 (0.995-0.999, SEM = 0.46) with the scores of two raters within the limits of agreement (mean dif  = -0.143 ± 0.727, p > 0.05) and test-retest reliability (ICC (95%CI) = 0.966 (0.926-0.988), SEM = 1.53). Additionally, the Mini-BESTest GR yielded very strong to moderate correlations with BBS GR (r = 0.924, p reliability and the equally good validity of the Mini-BESTest GR , strongly support its utility in Greek people with chronic stroke. Its ability to identify clinically meaningful changes and falls risk need further investigation.

  19. Effect of rater training on reliability and accuracy of mini-CEX scores: a randomized, controlled trial.

    Science.gov (United States)

    Cook, David A; Dupras, Denise M; Beckman, Thomas J; Thomas, Kris G; Pankratz, V Shane

    2009-01-01

    Mini-CEX scores assess resident competence. Rater training might improve mini-CEX score interrater reliability, but evidence is lacking. Evaluate a rater training workshop using interrater reliability and accuracy. Randomized trial (immediate versus delayed workshop) and single-group pre/post study (randomized groups combined). Academic medical center. Fifty-two internal medicine clinic preceptors (31 randomized and 21 additional workshop attendees). The workshop included rater error training, performance dimension training, behavioral observation training, and frame of reference training using lecture, video, and facilitated discussion. Delayed group received no intervention until after posttest. Mini-CEX ratings at baseline (just before workshop for workshop group), and four weeks later using videotaped resident-patient encounters; mini-CEX ratings of live resident-patient encounters one year preceding and one year following the workshop; rater confidence using mini-CEX. Among 31 randomized participants, interrater reliabilities in the delayed group (baseline intraclass correlation coefficient [ICC] 0.43, follow-up 0.53) and workshop group (baseline 0.40, follow-up 0.43) were not significantly different (p = 0.19). Mean ratings were similar at baseline (delayed 4.9 [95% confidence interval 4.6-5.2], workshop 4.8 [4.5-5.1]) and follow-up (delayed 5.4 [5.0-5.7], workshop 5.3 [5.0-5.6]; p = 0.88 for interaction). For the entire cohort, rater confidence (1 = not confident, 6 = very confident) improved from mean (SD) 3.8 (1.4) to 4.4 (1.0), p = 0.018. Interrater reliability for ratings of live encounters (entire cohort) was higher after the workshop (ICC 0.34) than before (ICC 0.18) but the standard error of measurement was similar for both periods. Rater training did not improve interrater reliability or accuracy of mini-CEX scores. clinicaltrials.gov identifier NCT00667940

  20. A mini axial and a permanent maglev radial heart pump.

    Science.gov (United States)

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-05-31

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements.The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004.The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure.An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation.

  1. Journal of the Cameroon Academy of Sciences: About this journal

    African Journals Online (AJOL)

    Journal of the Cameroon Academy of Sciences: About this journal. Journal Home > Journal of the Cameroon Academy of Sciences: About this journal. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search ...

  2. Dark Matter Search in a Proton Beam Dump with MiniBooNE.

    Science.gov (United States)

    Aguilar-Arevalo, A A; Backfish, M; Bashyal, A; Batell, B; Brown, B C; Carr, R; Chatterjee, A; Cooper, R L; deNiverville, P; Dharmapalan, R; Djurcic, Z; Ford, R; Garcia, F G; Garvey, G T; Grange, J; Green, J A; Huelsnitz, W; de Icaza Astiz, I L; Karagiorgi, G; Katori, T; Ketchum, W; Kobilarcik, T; Liu, Q; Louis, W C; Marsh, W; Moore, C D; Mills, G B; Mirabal, J; Nienaber, P; Pavlovic, Z; Perevalov, D; Ray, H; Roe, B P; Shaevitz, M H; Shahsavarani, S; Stancu, I; Tayloe, R; Taylor, C; Thornton, R T; Van de Water, R; Wester, W; White, D H; Yu, J

    2017-06-02

    The MiniBooNE-DM Collaboration searched for vector-boson mediated production of dark matter using the Fermilab 8-GeV Booster proton beam in a dedicated run with 1.86×10^{20} protons delivered to a steel beam dump. The MiniBooNE detector, 490 m downstream, is sensitive to dark matter via elastic scattering with nucleons in the detector mineral oil. Analysis methods developed for previous MiniBooNE scattering results were employed, and several constraining data sets were simultaneously analyzed to minimize systematic errors from neutrino flux and interaction rates. No excess of events over background was observed, leading to a 90% confidence limit on the dark matter cross section parameter, Y=ε^{2}α_{D}(m_{χ}/m_{V})^{4}≲10^{-8}, for α_{D}=0.5 and for dark matter masses of 0.01dark matter. This is the best limit from a dedicated proton beam dump search in this mass and coupling range and extends below the mass range of direct dark matter searches. These results demonstrate a novel and powerful approach to dark matter searches with beam dump experiments.

  3. Human mini-guts: new insights into intestinal physiology and host-pathogen interactions.

    Science.gov (United States)

    In, Julie G; Foulke-Abel, Jennifer; Estes, Mary K; Zachos, Nicholas C; Kovbasnjuk, Olga; Donowitz, Mark

    2016-11-01

    The development of indefinitely propagating human 'mini-guts' has led to a rapid advance in gastrointestinal research related to transport physiology, developmental biology, pharmacology, and pathophysiology. These mini-guts, also called enteroids or colonoids, are derived from LGR5 + intestinal stem cells isolated from the small intestine or colon. Addition of WNT3A and other growth factors promotes stemness and results in viable, physiologically functional human intestinal or colonic cultures that develop a crypt-villus axis and can be differentiated into all intestinal epithelial cell types. The success of research using human enteroids has highlighted the limitations of using animals or in vitro, cancer-derived cell lines to model transport physiology and pathophysiology. For example, curative or preventive therapies for acute enteric infections have been limited, mostly due to the lack of a physiological human intestinal model. However, the human enteroid model enables specific functional studies of secretion and absorption in each intestinal segment as well as observations of the earliest molecular events that occur during enteric infections. This Review describes studies characterizing these human mini-guts as a physiological model to investigate intestinal transport and host-pathogen interactions.

  4. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    Science.gov (United States)

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.

  5. Safety and efficacy of unidirectional barbed suture in mini-laparotomy myomectomy

    Directory of Open Access Journals (Sweden)

    Ming-Chao Huang

    2013-03-01

    Conclusion: The unidirectional knotless barbed suture may facilitate the repair of uterine defects during mini-laparotomy myomectomy by significantly lowering operative time. It may also reduce the intraoperative blood loss.

  6. The October 2014 United States Treasury bond flash crash and the contributory effect of mini flash crashes.

    Directory of Open Access Journals (Sweden)

    Zachary S Levine

    Full Text Available We investigate the causal uncertainty surrounding the flash crash in the U.S. Treasury bond market on October 15, 2014, and the unresolved concern that no clear link has been identified between the start of the flash crash at 9:33 and the opening of the U.S. equity market at 9:30. We consider the contributory effect of mini flash crashes in equity markets, and find that the number of equity mini flash crashes in the three-minute window between market open and the Treasury Flash Crash was 2.6 times larger than the number experienced in any other three-minute window in the prior ten weekdays. We argue that (a this statistically significant finding suggests that mini flash crashes in equity markets both predicted and contributed to the October 2014 U.S. Treasury Bond Flash Crash, and (b mini-flash crashes are important phenomena with negative externalities that deserve much greater scholarly attention.

  7. The October 2014 United States Treasury bond flash crash and the contributory effect of mini flash crashes.

    Science.gov (United States)

    Levine, Zachary S; Hale, Scott A; Floridi, Luciano

    2017-01-01

    We investigate the causal uncertainty surrounding the flash crash in the U.S. Treasury bond market on October 15, 2014, and the unresolved concern that no clear link has been identified between the start of the flash crash at 9:33 and the opening of the U.S. equity market at 9:30. We consider the contributory effect of mini flash crashes in equity markets, and find that the number of equity mini flash crashes in the three-minute window between market open and the Treasury Flash Crash was 2.6 times larger than the number experienced in any other three-minute window in the prior ten weekdays. We argue that (a) this statistically significant finding suggests that mini flash crashes in equity markets both predicted and contributed to the October 2014 U.S. Treasury Bond Flash Crash, and (b) mini-flash crashes are important phenomena with negative externalities that deserve much greater scholarly attention.

  8. PV-HYBRID and MINI-GRID. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Within the 3rd European Conference at the Centre de Congres in Aix en Provence (France) between 11th and 12th May, 2006, the following lessons were held: (1) Small electric networks: European drivers and projects for the integration of RES and DG into the electricity grids of the future (Manuel Sanchez-Jimenez); (2) PV hybrid system within mini grids - IEA PVPS programme (Meuch Konraf); (3) Renewables for the developing world (Alvaro Ponce Plaza); (4) Rural electicity supply using photovoltaic / - Diesel hybrid systems: Attractive for investors in the renewable energy sector? (Andreas Hahn); (5) Economic analysis of stand-alone and grid-connected photovoltaic systems under current tariff structure of Taiwan (Yaw-Juen Wang); (6) Using wind-PV-diesel hybrid system for electrification of remote village in Western Libya (N.M. Kreama); (7) Venezuela's renewable energy program for small towns and rural areas ''Sembrando Luz'' (Jorge Torres); (8) AeroSmart5, the professional, sysem-compatible small-scale wind energy converter will be tested in field tests (Fabian Jochem); (9) Lifetime, test procedures and recommendations for optimal operating strategies for lead-acid-batteries in renewable energy systems - A survey on results from European projects from the 5th framework programme (Rudi Kaiser); (10) Prototype of a reversible fuel cell system for autonomous power supplies (Tom Smolinska); (11) Interconnection management in microgrids (Michel Vandenbergh); (12) Control strategy for a small-scale stand-alone power system based on renewable energy and hydrogen (Harald Miland); (13) Standard renewable electricity supply for people in rural areas - mini-grids in western provinces of China (Michael Wollny); (14) The Brava island a ''100% renewable energy'' project (Jean-Christian Marcel); (15) Breakthrough to a new era of PV-hybrid systems with the help of standardised components communication? (Michael Mueller); (16) Standardized

  9. Creative Artist: A Journal of Theatre and Media Studies: Journal ...

    African Journals Online (AJOL)

    Creative Artist: A Journal of Theatre and Media Studies: Journal Sponsorship. Journal Home > About the Journal > Creative Artist: A Journal of Theatre and Media Studies: Journal Sponsorship. Log in or Register to get access to full text downloads.

  10. Mini-open vacuum-assisted closure therapy with instillation for debilitated and septic patients with pleural empyema.

    Science.gov (United States)

    Sziklavari, Zsolt; Ried, Michael; Neu, Reiner; Schemm, Rudolf; Grosser, Christian; Szöke, Tamas; Hofmann, Hans-Stefan

    2015-08-01

    This prospective study is an evaluation of the mini-open vacuum-assisted closure with instillation (Mini-VAC-Instill) therapy for the treatment of complicated pleural empyema. We investigated septic patients in poor general physical condition (Karnofsky index ≤50%) with multimorbidity and/or immunosuppression who were treated by minimally invasive intrathoracic VAC-Instill therapy without the insertion of an open-window thoracostomy (OWT) between December 2012 and November 2014. All patients underwent mini-thoracotomy with position of a tissue retractor, surgical debridement and local decortication. Surgery was followed by intrathoracic vacuum therapy including periodic instillation using antiseptics. The VAC dressings were changed under general anaesthesia and the chest wall was closed during the same hospital stay. All patients received systemic antibiotic therapy. Fifteen patients (13 males, median age: 71 years) underwent intrathoracic Mini-VAC-Instill dressings for the management of pleural empyema without bronchopleural fistula. The median length of vacuum therapy was 9 days (5-25 days) and the median number of VAC changes per patient was 1 (1-5). In-hospital mortality was 6.7% (n = 1) and was not related to Mini-VAC-Instill therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in 85.7% of surviving patients (12 of 14). After the follow-up at an average of 13.2 months (range, 3-25 months), we observed recurrence once, 21 days after discharge. Two patients died in the late postoperative period (Day 43 and Day 100 after discharge) of fulminant urosepsis and carcinoma-related multiorgan failure, respectively. Analysis of the follow-up interviews in the outpatient clinic showed a good quality of life and a subjectively good long-term aesthetic result. Mini-VAC-Instill therapy is an upgrade of Mini-VAC, which guarantees the advantage of an open treatment, including flushing but without OWT. This

  11. The heterotic MiniLandscape and the 126 GeV Higgs boson

    Energy Technology Data Exchange (ETDEWEB)

    Badziak, Marcin [Warsaw Univ. (Poland). Inst. of Theoretical Physics, Faculty of Physics; Krippendorf, Sven; Nilles, Hans Peter [Bonn Univ. (Germany). Bethe Center for Theoretical Physics and Physikalisches Inst.; Winkler, Martin Wolfgang [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2012-12-15

    The MSSM candidates arising from the heterotic MiniLandscape feature a very constrained supersymmetry breaking pattern. This includes a fully predictable gaugino mass pattern, which is compressed compared to the CMSSM, and an inverted sfermion hierarchy due to distinct geometric localisation, featuring stops as light as 1 TeV. The observed Higgs mass sets a lower bound m{sub g} > 1.2 TeV on the gluino mass. The electroweak fine-tuning is reduced by a UV relation between the scalar mass of the two heavy families and the gluino mass. While large parts of the favoured parameter space escape detection at the LHC, the prospects to test the MiniLandscape models with future dark matter searches are very promising.

  12. Generation of sequence signatures from DNA amplification fingerprints with mini-hairpin and microsatellite primers.

    Science.gov (United States)

    Caetano-Anollés, G; Gresshoff, P M

    1996-06-01

    DNA amplification fingerprinting (DAF) with mini-hairpins harboring arbitrary "core" sequences at their 3' termini were used to fingerprint a variety of templates, including PCR products and whole genomes, to establish genetic relationships between plant tax at the interspecific and intraspecific level, and to identify closely related fungal isolates and plant accessions. No correlation was observed between the sequence of the arbitrary core, the stability of the mini-hairpin structure and DAF efficiency. Mini-hairpin primers with short arbitrary cores and primers complementary to simple sequence repeats present in microsatellites were also used to generate arbitrary signatures from amplification profiles (ASAP). The ASAP strategy is a dual-step amplification procedure that uses at least one primer in each fingerprinting stage. ASAP was able to reproducibly amplify DAF products (representing about 10-15 kb of sequence) following careful optimization of amplification parameters such as primer and template concentration. Avoidance of primer sequences partially complementary to DAF product termini was necessary in order to produce distinct fingerprints. This allowed the combinatorial use of oligomers in nucleic acid screening, with numerous ASAP fingerprinting reactions based on a limited number of primer sequences. Mini-hairpin primers and ASAP analysis significantly increased detection of polymorphic DNA, separating closely related bermudagrass (Cynodon) cultivars and detecting putatively linked markers in bulked segregant analysis of the soybean (Glycine max) supernodulation (nitrate-tolerant symbiosis) locus.

  13. The High-Level Interface Definitions in the ASTRI/CTA Mini Array Software System (MASS)

    Science.gov (United States)

    Conforti, V.; Tosti, G.; Schwarz, J.; Bruno, P.; Cefal‘A, M.; Paola, A. D.; Gianotti, F.; Grillo, A.; Russo, F.; Tanci, C.; Testa, V.; Antonelli, L. A.; Canestrari, R.; Catalano, O.; Fiorini, M.; Gallozzi, S.; Giro, E.; Palombara, N. L.; Leto, G.; Maccarone, M. C.; Pareschi, G.; Stringhetti, L.; Trifoglio, M.; Vercellone, S.; Astri Collaboration; Cta Consortium

    2015-09-01

    ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is a Flagship Project funded by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. Within this framework, INAF is currently developing an end-to-end prototype, named ASTRI SST-2M, of a Small Size Dual-Mirror Telescope for the Cherenkov Telescope Array, CTA. A second goal of the project is the realization of the ASTRI/CTA mini-array, which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The ASTRI Mini Array Software System (MASS) is designed to support the ASTRI/CTA mini-array operations. MASS is being built on top of the ALMA Common Software (ACS) framework, which provides support for the implementation of distributed data acquisition and control systems, and functionality for log and alarm management, message driven communication and hardware devices management. The first version of the MASS system, which will comply with the CTA requirements and guidelines, will be tested on the ASTRI SST-2M prototype. In this contribution we present the interface definitions of the MASS high level components in charge of the ASTRI SST-2M observation scheduling, telescope control and monitoring, and data taking. Particular emphasis is given to their potential reuse for the ASTRI/CTA mini-array.

  14. Journal Home

    African Journals Online (AJOL)

    for Researchers · for Journals · for Authors · for Policy Makers · about Open Access · Journal Quality. 521 African Journals. Browse By Category · Browse Alphabetically · Browse By Country · List All Titles · Free To Read Titles This Journal is Open Access. Featuring journals from 32 Countries: Algeria (5); Benin (2); Botswana ...

  15. Psychometric Properties of the Folstein Mini-Mental State Examination

    Science.gov (United States)

    Lopez, Michael N.; Charter, Richard A.; Mostafavi, Beeta; Nibut, Lorraine P.; Smith, Whitney E.

    2005-01-01

    Criterion-referenced (Livingston) and norm-referenced (Gilmer-Feldt) techniques were used to measure the internal consistency reliability of Folsteins Mini-Mental State Examination (MMSE) on a large sample (N = 418) of elderly medical patients. Two administration and scoring variants of the MMSE Attention and Calculation section (Serial 7s only…

  16. Comparing the Fullerton Advanced Balance Scale with the Mini-BESTest and Berg Balance Scale to assess postural control in patients with Parkinson disease.

    Science.gov (United States)

    Schlenstedt, Christian; Brombacher, Stephanie; Hartwigsen, Gesa; Weisser, Burkhard; Möller, Bettina; Deuschl, Günther

    2015-02-01

    To validate the Fullerton Advanced Balance (FAB) Scale for patients with idiopathic Parkinson disease (PD); and to compare the FAB Scale with the Mini-Balance Evaluation Systems Test (Mini-BESTest) and Berg Balance Scale (BBS). Observational study to assess concurrent validity, test-retest, and interrater reliability of the FAB Scale in patients with PD and to compare the distribution of the scale with the Mini-BESTest and BBS. University hospital in an urban community. Patients with idiopathic PD (N=85; Hoehn and Yahr stages 1-4). Not applicable. FAB Scale, Mini-BESTest, BBS, timed Up and Go test, Unified Parkinson's Disease Rating Scale, and visual analog scale. Interrater (3 raters) and test-retest (3±1 d) reliability were high for all scales (ICCs≥.95). The FAB Scale was highly correlated with the Mini-BESTest (Spearman ρ=.87) and timed Up and Go test item of the Mini-BESTest (Spearman ρ=.83). In contrast with the BBS, the FAB Scale and Mini-BESTest have only minimal ceiling effects. The FAB Scale demonstrated the most symmetric distribution when compared with the Mini-BESTest and BBS (skewness: FAB scale: -.54; Mini-BESTest: -1.07; BBS: -2.14). The FAB Scale is a valid and reliable tool to assess postural control in patients with PD. No ceiling effect was noted for the FAB Scale. Although the items of the FAB Scale are more detailed when compared with the Mini-BESTest, interrater and test-retest reliability were excellent. The scale is a promising tool to detect small changes of the postural control system in individuals with PD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. Mini-implants in orthodontics: A systematic review of the literature

    NARCIS (Netherlands)

    Reynders, Reint; Ronchi, Laura; Bipat, Shandra

    2009-01-01

    Introduction: In this article, we systematically reviewed the literature to quantify success and complications encountered with the use of mini-implants for orthodontic anchorage, and to analyze factors associated with success or failure. Methods: Computerized and manual searches were conducted up

  18. Classification of mini-dimmings associated with extreme ultraviolet eruptions by using graph theory

    Directory of Open Access Journals (Sweden)

    S Bazargan

    2016-09-01

    Full Text Available Coronal dimmings in both micro and macro scales, can be observed by extreme ultraviolet images, recorded from Solar Dynamics Observatory or Atmospheric Imaging Assembly (SDO/AIA. Mini-dimmings are sometimes associated with wave-like brightening, called coronal mass ejections. Here, the sun full disk images with 171 Å wavelenght, cadence of 2.5, and  0.6 arcsec cell size, were taken on 3 March 2012, then the obtained data were analyzed. Using Zernike Moment and Support Vector Machine (SVM, mini dimmings are detected. 538 active region events, 680 coronal hole events and 723 quiet sun events have been recognized using algorithm. The position, time duration and spatial expansion of these events were computed .The eruptive dimmings have a more spatial development than thermal dimmings after eruptions. This is evident in their graph characteristics length. Then, using graph theory, eruptive and thermal mini-dimmings were classified, with 13% error, for 200 dimmings. 68 dimmings were classified as thermal, and 132 as eruptive. To do this, evolution of graph characteristic length were used.

  19. Frontoplastia mini-invasiva Mini-invasive forehead-plasty

    Directory of Open Access Journals (Sweden)

    A. Fuente del Campo

    2009-06-01

    Full Text Available Una de las causas mas importantes de la flacidez y caída de la piel y de las partes blandas de la cara es la disminución del volumen de su estructura esquelética. Un factor fundamental en la restauración del envejecimiento facial seria el poder recuperar este volumen. Dado que en la actualidad no se cuenta con un recurso efectivo para recuperar el volumen óseo, lo indicado es restaurar la relación entre las partes blandas y el volumen óseo vigente. Esta es la meta mas importante de la ritidectomía subperióstica. Con una vasta experiencia en este método y buscando minimizar las cicatrices resultantes, hemos desarrollado el enfoque mini-invasivo de este procedimiento de restauración facial. En el presente trabajo describimos la aplicación de nuestro procedimiento para la restauración de la región frontal. Desde 1998 hemos realizado este procedimiento, con diversas combinaciones y variantes y dependiendo de las necesidades de cada caso, en un total de 521 pacientes: 419 mujeres y 102 hombres de edades comprendidas entre los 45 y los 73 años. Planteamos las metas y describimos los medios para realizar este procedimiento por vía frontal, transpalpebral y combinando ambas vías, a la vez que damos orientación para lograr los objetivos del procedimiento y evitar complicaciones basándonos en la Anatomía Quirúrgica. Referimos los procedimientos auxiliares que se pueden asociar a este método y describimos los detalles del manejo postoperatorio. Los resultados obtenidos han sido en general muy satisfactorios tanto para los pacientes como para el cirujano. Mencionamos también las complicaciones observadas. En conclusión, describimos las observaciones resultantes de nuestra experiencia con este método a lo largo de 10 años, con resultados tan buenos o mejores que con la ritidectomía subperióstica abierta y el porqué es actualmente nuestro procedimiento de elección.The reduction of the bony structure of the face is the main reason

  20. Cooling down MiniGRAIL to milli-Kelvin temperatures

    International Nuclear Information System (INIS)

    Waard, A de; Gottardi, L; Bassan, M; Coccia, E; Fafone, V; Flokstra, J; Karbalai-Sadegh, A; Minenkov, Y; Moleti, A; Pallottino, G V; Podt, M; Pors, B J; Reincke, W; Rocchi, A; Shumack, A; Srinivas, S; Visco, M; Frossati, G

    2004-01-01

    The latest developments in the construction of the ultra-cryogenic spherical detector MiniGRAIL are presented. The room temperature part of the vibration isolation system was improved and provided with an attenuation of about 60 dB around 3 kHz. The transfer function of the cryogenic stages gave about 20 dB per stage, at the resonant frequency of the sphere. The latest results of three cryogenic tests at ultra-low temperature of the spherical detector MiniGRAIL, using several thermal anchorings, are presented. Minimum temperatures of 20 mK on the mixing chamber of the dilution refrigerator and 79 mK on the surface of the sphere were reached. During the last cool down, two capacitive transducers were mounted on the sphere. The first was coupled to a room temperature FET amplifier and the second to a transformer and a double stage SQUID amplifier. Unfortunately the SQUID did not work, so only the first resonator could be used. An equivalent temperature of about 20 K was measured during an acquisition run of 7 h, using the first transducer corresponding to the FET white noise

  1. The nucleon axial mass and the MiniBooNE quasielastic neutrino-nucleus scattering problem

    International Nuclear Information System (INIS)

    Nieves, J.; Ruiz Simo, I.; Vicente Vacas, M.J.

    2012-01-01

    The charged-current double differential neutrino cross section, measured by the MiniBooNE Collaboration, has been analyzed using a microscopical model that accounts for, among other nuclear effects, long range nuclear (RPA) correlations and multinucleon scattering. We find that MiniBooNE data are fully compatible with the world average of the nucleon axial mass in contrast with several previous analyses which have suggested an anomalously large value. We also discuss the reliability of the algorithm used to estimate the neutrino energy.

  2. Evaluation of the Efficacy of the Mini Parasep SF Faecal Parasite ...

    African Journals Online (AJOL)

    Evaluation of the Efficacy of the Mini Parasep SF Faecal Parasite Concentrator; A New Technique against the Direct Smear and Formol Ether Concentration Technique for the Detection of Intestinal Parasites in Stool.

  3. Developments in Miniaturized Laser Heterodyne Radiometer (mini-LHR) construction for groundtruth measurements of CH4 and CO2 in harsh terrain

    Science.gov (United States)

    DiGregorio, A.; Wilson, E. L.; Hoffman, C.; Grunberg, C.; Mao, J.; Ramanathan, A. K.

    2016-12-01

    We present an updated, ruggedized design of NASA Goddard Space Flight Center's Miniaturized Laser Heterodyne Radiometer (mini-LHR), and the results of testing in the Bonanza Creek Research Forest. The mini-LHR is a passive variation of typical heterodyne radiometry instruments, designed to work in tandem with the AERONET sun photometer for collection of column methane (CH4) and carbon dioxide (CO2) in harsh environments. Advancements in the development of the Cube-Sat version of the mini-LHR have allowed a more than 50% reduction in size, weight, and power usage of the mini-LHR. Now small enough to fit in a medium handbag, the mini-LHR can be run off of a small 35 Watt solar panel and backup battery for continuous measurement. Using a touch-screen control interface built off of a Raspberry Pi, the updated mini-LHR is capable of data collection and preliminary data processing, even without internet, cellular, or satellite connectivity. The improvements made to the mini-LHR were tested in a field campaign in May 2016 funded under NASA's IDS program to track CH4 and CO2 emissions above thawing permafrost. In addition to being a comprehensive study of methane release from thawing permafrost, this pilot study tested the ruggedization and functionality of the instrument in three different environments- a black spruce forest, collapsed scar bog, and fen.

  4. Some characteristics of developing bubbly flow in a vertical mini pipe

    International Nuclear Information System (INIS)

    Hibiki, T.; Hazuku, T.; Takamasa, T.; Ishii, M.

    2007-01-01

    Accurate prediction of the flow parameters is essential to successful development of the interfacial transfer terms in the two-phase flow formulation in a mini channel. From this point of view, axial measurements of flow parameters such as void fraction, interfacial area concentration, gas velocity, bubble Sauter mean diameter, and bubble number density were performed by the image processing method at five axial locations in vertical upward developing bubbly flows using a 1.02 mm-diameter pipe. The frictional pressure loss was also measured by a differential pressure cell. In the experiment, the superficial liquid velocity and the void fraction ranged from 1.02 m/s to 4.89 m/s and from 0.980% to 24.6%, respectively. The constitutive equation for the drift velocity applicable to mini channel flow was developed by considering the effect of the frictional pressure loss on the drift velocity. The constitutive equation for the distribution parameter was also developed by considering the flow transition from laminar to turbulent flows. The drift-flux model with the modeled constitutive equations for the distribution parameter and drift velocity agreed with the measured void fractions within the averaged prediction accuracy of ±6.76%. The applicability of the existing interfacial area concentration model to mini channel flow was validated by the measured interfacial data

  5. Experimental investigation on flow instability of forced circulation in a vertical mini-rectangular channel

    International Nuclear Information System (INIS)

    Yu Zhiting; Tan Sichao; Yuan Hongsheng; Zhuang Nailiang; Chen Hanying

    2015-01-01

    An experimental study was conducted to investigate the flow instability in a vertical mini-rectangular channel with distilled water as the working fluid. The rotational speed of the primary pump is gradually reduced to lower the inlet flow rate until the flow becomes unstable, while maintaining all other thermal parameters unchanged. Three types of instability, characterized by large amplitude oscillation, small amplitude oscillation and flow excursion, were identified from the experimental data. A stability map for the vertical mini-rectangular channel under forced circulation was established based on the Subcooling number and Phase Change number. The oscillation periods were correlated with the fluid transit time and the boiling delay time. A flow pattern map for vertical upward flow in a mini-rectangular channel was applied to confirm the flow patterns during the oscillation. The mechanisms of the three types of instability were obtained by considering several types of flow instabilities and comparing them with the oscillations observed in this work. (author)

  6. Improvement of Student Critical Thinking Skills with the Natural Product Mini Project Laboratory Learning

    Directory of Open Access Journals (Sweden)

    Aliefman Hakim

    2016-12-01

    Full Text Available This research aims to investigate effect of learning using natural product mini project laboratory on students’ critical thinking skills. The research was conducted on sixth semester of 59 students of chemistry and chemistry education program from one of the state universities in West Nusa Tenggara, Indonesia in 2012/2013. This research revealed class where the student learn using natural product mini project laboratory had more critical thinking skills than those using verification laboratory. The average n-gain of critical thinking skills for experiment class was 0.58 while for the control class was 0.37. The highest n-gain in the experiment class was 0.70 for “deciding on an action (selecting criteria to judge possible solutions indicators”, while the smallest n-gain was 0.47 for “the making and judging value of judgments (balancing, weighing, and deciding indicators. We concluded that the natural product mini project laboratory was better than verification laboratory in improving the students’ critical thinking skills.

  7. Micro packaging of hermetic seal mini dual in line laser diode module for aerospace applications

    Science.gov (United States)

    Kazemi, Alex A.; Chan, Eric; Koshinz, Dennis

    2014-09-01

    Normally, reliable, reproducible, high-yield packaging technologies are essential for meeting the cost, performance, and service objectives for the harsh environment of space applications. This paper describes a new improved micro packaging method of hermetic seal mini-DIL (dual in line) laser diode module. The problem of using a softer solder resulted in failure mechanisms observed in the mini-DIL laser diode module based laser firing unit (LFU) for ordinance ignition of a missile system. These failures included: (1) failure in light output pulse power, (2) fiber pigtail damage inside the package snout which caused low LFU production yield. Our distinctive challenge for this project is the micro packaging of mini-DIL. For this package a new technique for the hermetic sealing using a micro-soldering process was developed. The process is able to confine the solder seal to a small region inside the snout near the fiber feed-through hole on the wall of the mini-DIL package. After completing the development, which included temperature and thermal cycling, X-rays analysis showed the new method had no fiber damage after the microsoldering seal. The new process resulted in 100% success in the packaging design and was granted a patent for the innovative development.

  8. SQUID developments for the gravitational wave antenna MiniGRAIL

    NARCIS (Netherlands)

    Pleikies, J.; Usenko, O.; Kuit, K.H.; Flokstra, Jakob; de Waard, A.; de Waard, A.; Frossati, G.

    2007-01-01

    We designed two different sensor SQUIDs for the readout of the resonant mass gravitational wave detector MiniGRAIL. Both designs have integrated input inductors in the order of 1.5 muH and are planned for operation in the mK temperature range. Cooling fins were added to the shunt resistors. The

  9. Journal of Technology and Education in Nigeria: About this journal

    African Journals Online (AJOL)

    Journal of Technology and Education in Nigeria: About this journal. Journal Home > Journal of Technology and Education in Nigeria: About this journal. Log in or Register to get access to full text downloads.

  10. East and Central African Journal of Surgery: About this journal

    African Journals Online (AJOL)

    East and Central African Journal of Surgery: About this journal. Journal Home > East and Central African Journal of Surgery: About this journal. Log in or Register to get access to full text downloads.

  11. Ethiopian Journal of Business and Economics (The): About this journal

    African Journals Online (AJOL)

    Ethiopian Journal of Business and Economics (The): About this journal. Journal Home > Ethiopian Journal of Business and Economics (The): About this journal. Log in or Register to get access to full text downloads.

  12. Zagazig Journal of Occupational Health and Safety: About this journal

    African Journals Online (AJOL)

    Zagazig Journal of Occupational Health and Safety: About this journal. Journal Home > Zagazig Journal of Occupational Health and Safety: About this journal. Log in or Register to get access to full text downloads.

  13. Journal of Computer Science and Its Application: About this journal

    African Journals Online (AJOL)

    Journal of Computer Science and Its Application: About this journal. Journal Home > Journal of Computer Science and Its Application: About this journal. Log in or Register to get access to full text downloads.

  14. Nigeria Journal of Pure and Applied Physics: About this journal

    African Journals Online (AJOL)

    Nigeria Journal of Pure and Applied Physics: About this journal. Journal Home > Nigeria Journal of Pure and Applied Physics: About this journal. Log in or Register to get access to full text downloads.

  15. Examining the reliability and validity of the Hebrew version of the Mini Mental State Examination.

    Science.gov (United States)

    Werner, P; Heinik, J; Mendel, A; Reicher, B; Bleich, A

    1999-10-01

    The Mini Mental State Examination is used worldwide for the screening and diagnosis of dementia. The aim of the present study was to examine the reliability and validity of the Hebrew version of the Mini Mental State Examination. The Hebrew version of the Mini Mental State Examination was administered to 36 demented and 19 non-demented elderly persons. Test-retest reliability scores were calculated as exact agreement rates, and ranged from good to excellent for all the items. Strong convergent validity, as measured by the correlation between the MMSE and the CAM-COG (r = 0.94), was found. Good predictive value was observed as over three-quarters of the participants were correctly classified as demented or non-demented. The Hebrew version of the MMSE was found to be a useful and valid instrument for the determination of dementia in the elderly population.

  16. Open Access Journal Policies: A Systematic Analysis of Radiology Journals.

    Science.gov (United States)

    Narayan, Anand; Lobner, Katie; Fritz, Jan

    2018-02-01

    The open access movement has pushed for greater access to scientific knowledge by expanding access to scientific journal articles. There is limited information about the extent to which open access policies have been adopted by radiology journals. We performed a systematic analysis to ascertain the proportion of radiology journals with open access options. A search was performed with the assistance of a clinical informationist. Full and mixed English-language diagnostic and interventional radiology Web of Science journals (impact factors > 1.0) were included. Nuclear medicine, radiation oncology, physics, and solicitation-only journals were excluded. Primary outcome was open access option (yes or no) with additional outcomes including presence or absence of embargo, complete or partial copyright transfer, publication fees, and self-archiving policies. Secondary outcomes included journal citations, journal impact factors, immediacy, Eigenfactor, and article influence scores. Independent double readings were performed with differences resolved by consensus, supplemented by contacting editorial staff at each journal. In all, 125 journals were identified; review yielded 49 journals (39%, mean impact factor of 2.61). Thirty-six of the journals had open access options (73.4%), and four journals were exclusively open access (8.2%). Twelve-month embargoes were most commonly cited (90.6%) with 28.6% of journals stating that they did not require a complete transfer of copyright. Prices for open access options ranged from $750 to $4,000 (median $3,000). No statistically significant differences were found in journal impact measures comparing journals with open access options to journals without open access options. Diagnostic and interventional radiology journals have widely adopted open access options with a few radiology journals being exclusively open access. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  17. Effects of gripping volume in the mechanical strengths of orthodontic mini-implant

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Tseng

    2017-11-01

    Full Text Available The objective of study was to investigate the correlation between the mechanical strengths [insertion torque (IT; resonance frequency (RF; and horizontal pullout strength (HPS] and gripping volume (GV of mini-implants. Thirty mini-implants of three types (Type A: 2 mm × 10 mm, cylindrical, titanium alloy; Type B: 2 mm × 10 mm, tapered, stainless steel; and Type C: 2 mm × 11 mm, cylindrical, titanium alloy were inserted 7 mm into artificial bones. One-way analysis of variance and Spearman's test were applied to assess intergroup comparisons and intragroup correlations. The null hypothesis was that no statistically significant correlations exist between the GV and mechanical strengths (IT, RF, and HPS. In the IT test, Type C (14.2 Ncm had significantly (p=0.016 greater values than did Type A (12.4 Ncm. In the RF analysis, no significant difference was observed among the three types of mini-implants. In the HPS test, Type C (388.9 Ncm was significantly larger than both Type B (294.5 Ncm and Type A (286 Ncm. In the GV measurement, Type C (14.4 mm3 was significantly larger than Type B (11.4 mm3 and Type A (9.2 mm3. Type A and Type B exhibited no significant correlations among the tests. Therefore, the null hypothesis was accepted. Although no significant correlation was noted between the GV and mechanical strengths (IT, RF, and HPS, we observed a trend that the mechanical strengths (IT, RF, and HPS of the mini-implants corresponded to the order and values of GV (Type C > Type B > Type A.

  18. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  19. Well-Being of Lagos Urban Mini-Bus Drivers: The Influence of Age and Marital Status

    OpenAIRE

    Bolajoko I. Malomo; Maryam O. Yusuf

    2015-01-01

    Lagos urban mini bus drivers play a critical role in the transportation sector. The current major mode of transportation within Lagos metropolis remains road transportation and this confirms the relevance of urban mini-bus drivers in transporting the populace to their various destinations. Other modes of transportation such as the train and waterways are currently inadequate. Various threats to the well-being of urban bus drivers include congested traffic typical of moder...

  20. Comparison of the Mini-Balance Evaluations Systems Test with the Berg Balance Scale in relationship to walking speed and motor recovery post stroke.

    Science.gov (United States)

    Madhavan, Sangeetha; Bishnoi, Alka

    2017-12-01

    The Mini-BESTest is a recently developed balance assessment tool that incorporates challenging dynamic balance tasks. Few studies have compared the psychometric properties of the Mini-BESTest to the commonly used Berg Balance Scale (BBS). However, the utility of these scales in relationship to post stroke walking speeds has not been explored. The purpose of this study was to compare the sensitivity and specificity of the Mini-BESTest and BBS to evaluate walking speeds in individuals with stroke. A retrospective exploratory design. Forty-one individuals with chronic stroke were evaluated with the Mini-BESTest, BBS, and 10-meter self-selected walk test (10MWT). Based on their self-selected gait speeds (below or above 0.8 m/s), participants were classified as slow and fast walkers. Significant linear correlations were observed between the Mini-BESTest vs. BBS (r = 0.72, p ≤ 0.001), Mini-BESTest vs. 10MWT (r = 0.58, p ≤ 0.001), and BBS vs. 10MWT (r = 0.30, p = 0.05). Independent t-tests comparing the balance scores for the slow and fast walkers revealed significant group differences for the Mini-BESTest (p = 0.003), but not for the BBS (p = 0.09). The Mini-BESTest demonstrated higher sensitivity (93%) and specificity (64%) compared to the BBS (sensitivity 81%, specificity 56%) for discriminating participants into slow and fast walkers. The Mini-BESTest has a greater discriminative ability than the BBS to categorize individuals with stroke into slow and fast walkers.

  1. Mini-craniotomy under local anaesthesia and sedation as a less ...

    African Journals Online (AJOL)

    Mini-craniotomy under local anaesthesia and sedation as a less invasive procedure for spontaneous intracerebral haemorrhage in a developing country. ... The ICH showed evidence of significant mass effect on brain computed tomography (CT) scan in 95% and was associated with intraventricular haemorrhage in 43%.

  2. Resonance – Journal of Science Education | Indian Academy of ...

    Indian Academy of Sciences (India)

    Events · Annual Meetings · Mid Year Meetings · Discussion Meetings · Public Lectures · Lecture Workshops · Refresher Courses · Symposia · Live Streaming. Home; Journals; Resonance – Journal of Science Education; Volume 22; Issue 2. Understanding Active Metal Reaction Kinetis with Cu-Mg Replacement Reaction.

  3. A new dynamism for the cogeneration of 2000 - from the medium to the mini-cogeneration; Une nouvelle dynamique pour la cogeneration en l'an 2000 - de la moyenne vers le mini-cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In the framework of the Eco-Industries 2000 meeting, the ATEE organized a colloquium on the medium and mini-cogeneration market. This book presents the fourteen papers proposed at this colloquium bringing information on the cogeneration technology for the medium and mini-systems. The state of the art concerning the turbines and examples of dual systems (heating and warm water) are provided. Some economical aspects are also presented with the international and national market, the contracts management with EDF and the investments. (A.L.B.)

  4. From Journalism Studies to Journalism Theory

    OpenAIRE

    Elias Machado

    2005-01-01

    This paper comprises three parts –- 1) recognition of professional practice as a legitimate object of research; 2) development of methodologies that are adjusted to the particularities of the area; and 3) funding of multidisciplinary experiments on applied research. My intention here is to build on the mapping of existing studies to discuss some assumptions and to consolidate journalism as a fi eld of knowledge, based on the distinction between journalism studies and journalism theories.

  5. The Factors of Local Energy Transition in the Seoul Metropolitan Government: The Case of Mini-PV Plants

    Directory of Open Access Journals (Sweden)

    Jae-Seung Lee

    2017-03-01

    Full Text Available As a way of enhancing urban sustainability, Seoul Special City, the capital of South Korea, has shown strong enthusiasm for urban energy transition by tackling climate change and expanding renewable energy. The Seoul Metropolitan Government (SMG has adopted the “One Less Nuclear Power Plant (OLNPP” strategy since April 2012 and specific policy measures, including a mini-photovoltaic (PV plant program, were introduced to facilitate the energy transition. However, varying degrees of success were achieved by 25 district-level local governments (Gu with mini-PV plant programs. This study explored the reason why those local governments showed different levels of performance despite the strong will of municipal government (SMG to implement urban energy transitions through the mini-PV plant program. The tested hypotheses were based on capacity, political context, public awareness and geographical diffusion. The findings indicated that institutional capacity, financial dependence, political orientation and public perception had positively affected the performance of mini-PV plant installation at each district level. Especially, the political will of each district mayor played an important role in the implementation of the policy.

  6. Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration.

    Directory of Open Access Journals (Sweden)

    Djibril Wade

    Full Text Available A new CD4 point-of-care instrument, the CyFlow miniPOC, which provides absolute and percentage CD4 T-cells, used for screening and monitoring of HIV-infected patients in resource-limited settings, was introduced recently. We assessed the performance of this novel instrument in a reference laboratory and in a field setting in Senegal.A total of 321 blood samples were obtained from 297 adults and 24 children, all HIV-patients attending university hospitals in Dakar, or health centers in Ziguinchor. Samples were analyzed in parallel on CyFlow miniPOC, FACSCount CD4 and FACSCalibur to assess CyFlow miniPOC precision and accuracy.At the reference lab, CyFlow miniPOC, compared to FACSCalibur, showed an absolute mean bias of -12.6 cells/mm3 and a corresponding relative mean bias of -2.3% for absolute CD4 counts. For CD4 percentages, the absolute mean bias was -0.1%. Compared to FACSCount CD4, the absolute and relative mean biases were -31.2 cells/mm3 and -4.7%, respectively, for CD4 counts, whereas the absolute mean bias for CD4 percentages was 1.3%. The CyFlow miniPOC was able to classify HIV-patients eligible for ART with a sensitivity of ≥ 95% at the different ART-initiation thresholds (200, 350 and 500 CD4 cells/mm3. In the field lab, the room temperature ranged from 30 to 35°C during the working hours. At those temperatures, the CyFlow miniPOC, compared to FACSCount CD4, had an absolute and relative mean bias of 7.6 cells/mm3 and 2.8%, respectively, for absolute CD4 counts, and an absolute mean bias of 0.4% for CD4 percentages. The CyFlow miniPOC showed sensitivity equal or greater than 94%.The CyFlow miniPOC showed high agreement with FACSCalibur and FACSCount CD4. The CyFlow miniPOC provides both reliable absolute CD4 counts and CD4 percentages even under the field conditions, and is suitable for monitoring HIV-infected patients in resource-limited settings.

  7. Beyond journalism: Theorizing the transformation of journalism.

    Science.gov (United States)

    Deuze, Mark; Witschge, Tamara

    2018-02-01

    Journalism has enjoyed a rich and relatively stable history of professionalization. Scholars coming from a variety of disciplines have theorized this history, forming a consistent body of knowledge codified in national and international handbooks and canonical readers. However, recent work and analysis suggest that the supposed core of journalism and the assumed consistency of the inner workings of news organizations are problematic starting points for journalism studies. In this article, we challenge the consensual (self-)presentation of journalism - in terms of its occupational ideology, its professional culture, and its sedimentation in routines and organizational structures (cf. the newsroom) in the context of its reconfiguration as a post-industrial , entrepreneurial , and atypical way of working and of being at work. We outline a way beyond individualist or institutional approaches to do justice to the current complex transformation of the profession. We propose a framework to bring together these approaches in a dialectic attempt to move through and beyond journalism as it has traditionally been conceptualized and practiced, allowing for a broader definition and understanding of the myriad of practices that make up journalism.

  8. Cutting edge pre-intermediate : student's book : with mini-dictionary

    CERN Document Server

    Cunningham, Sarah; Comyns Carr, Jane

    2001-01-01

    A focus on high-frequency useful vocabulary helps students say what they want to say. Regular, well-structured speaking tasks encourage students to express themselves more extensively and fluently. ‘Do You Remember’ sections in every unit and extra. Consolidation modules provide regular review and consolidation Student Books include Mini-Dictionary to help learners study independently.

  9. From Journalism Studies to Journalism Theory

    Directory of Open Access Journals (Sweden)

    Elias Machado

    2005-06-01

    Full Text Available This paper comprises three parts –- 1 recognition of professional practice as a legitimate object of research; 2 development of methodologies that are adjusted to the particularities of the area; and 3 funding of multidisciplinary experiments on applied research. My intention here is to build on the mapping of existing studies to discuss some assumptions and to consolidate journalism as a fi eld of knowledge, based on the distinction between journalism studies and journalism theories.

  10. Mini soap operas foster financial education and inclusion of women ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-05-04

    May 4, 2016 ... Mini soap operas foster financial education and inclusion of women in Peru ... they are less vulnerable to external shocks and can invest in health, education, ... was launched to encourage saving among women who received benefits under ... Evaluating vocational training program for women in Brazil.

  11. 'Mini'-Roadmapping - Ensuring Timely Sites' Cleanup/Closure by Resolving Science and Technology Issues

    International Nuclear Information System (INIS)

    Dale Luke; James Murphy

    2003-01-01

    Roadmapping is a powerful tool to manage technical risks and opportunities associated with complex problems. Roadmapping identifies technical capabilities required for both project- and program-level efforts and provides the basis for plans that ensure the necessary enabling activities will be done when needed. Roadmapping reveals where to focus further development of the path forward by evaluating uncertainties for levels of complexity, impacts, and/or the potential for large payback. Roadmaps can be customized to the application, a ''graded approach'' if you will. Some roadmaps are less detailed. We have called these less detailed, top-level roadmaps ''mini-roadmaps''. These miniroadmaps are created to tie the needed enablers (e.g., technologies, decisions, etc.) to the functions. If it is found during the mini-roadmapping that areas of significant risk exist, then those can be road mapped further to a lower level of detail. Otherwise, the mini-roadmap may be sufficient to manage the project/program risk. Applying a graded approach to the roadmapping can help keep the costs down. Experience has indicated that it is best to do mini-roadmapping first and then evaluate the risky areas to determine whether to further evaluate those areas. Roadmapping can be especially useful for programs/projects that have participants from multiple sites, programs, or other entities which are involved. Increased synergy, better communications, and increased cooperation are the results from roadmapping a program/project with these conditions. And, as with any trip, the earlier you use a roadmap, the more confidence you will have that you will arrive at your destination with few, if any, problems. The longer the trip or complicated the route, the sooner the map is needed. This analogy holds true for using roadmapping for laying out program/project baselines and any alternative (contingency) plans. The mini-roadmapping process has been applied to past projects like the hydrogen gas

  12. System design description for mini-dacs data acquisition and control system

    International Nuclear Information System (INIS)

    Vargo, F.G. Jr.; Trujillo, L.T.; Smith, S.O.

    1994-01-01

    This document describes the hardware computer system, for the mini data acquisition and control system (DACS) that was fabricated by Los Alamos National Laboratory (LANL), to support the testing of the spare mixer pump for SY-101

  13. Mini-RF S- and X-band Bistatic Observations of the Floor of Cabeus Crater

    Science.gov (United States)

    Patterson, Gerald Wesley; Stickle, Angela; Turner, Franklin; Jensen, James; Cahill, Joshua; Mini-RF Team

    2017-10-01

    The Mini-RF instrument aboard NASA’s Lunar Reconnaissance Orbiter (LRO) is a hybrid dual-polarized synthetic aperture radar (SAR) and operates in concert with the Arecibo Observatory (AO) and the Goldstone deep space communications complex 34 meter antenna DSS-13 to collect S- and X-band bistatic radar data of the Moon. Bistatic radar data provide a means to probe the near subsurface for the presence of water ice, which exhibits a strong response in the form of a Coherent Backscatter Opposition Effect (CBOE). This effect has been observed in radar data for the icy surfaces of the Galilean satellites, the polar caps of Mars, polar craters on Mercury, and terrestrial ice sheets in Greenland. Previous work using Mini-RF S-band (12.6 cm) bistatic data suggests the presence of a CBOE associated with the floor of the lunar south polar crater Cabeus. The LRO spacecraft has begun its third extended mission. For this phase of operations Mini-RF is leveraging the existing AO architecture to make S-band radar observations of additional polar craters (e.g., Haworth, Shoemaker, Faustini). The purpose of acquiring these data is to determine whether other polar craters exhibit the response observed for Cabeus. Mini-RF has also initiated a new mode of operation that utilizes the X-band (4.2cm) capability of the instrument receiver and a recently commissioned X/C-band transmitter within the Deep Space Network’s (DSN) Goldstone complex to collect bistatic X-band data of the Moon. The purpose of acquiring these data is to constrain the depth/thickness of materials that exhibit a CBOE response - with an emphasis on observing the floor of Cabeus. Recent Mini-RF X-band observations of the floors of the craters Cabeus do not show evidence for a CBOE. This would suggest that the upper ~0.5 meters of the regolith for the floor of Cabeus do not harber water ice in a form detectable at 4.2 cm wavelengths.

  14. Mini-open spinal column shortening for the treatment of adult tethered cord syndrome.

    Science.gov (United States)

    Safaee, Michael M; Winkler, Ethan A; Chou, Dean

    2017-10-01

    Tethered cord syndrome (TCS) is a challenging entity characterized by adhesions at the caudal spinal cord that prevent upward movement during growth and result in stretching of the cord with a concomitant constellation of neurologic symptoms. Although growth in height stops in adulthood, some patients still develop progressive symptoms; many underwent detethering as a child or adolescent, resulting in significant scar tissue and re-tethering. Recent strategies have focused on spinal column shortening to reduce tension on the spinal cord without exposing the previous de-tethering site. Mini-open and minimally invasive approaches avoid the large dissection and exposure associated with traditional approaches and are associated with reduced blood loss, shorter hospital stay, and similar outcomes when compared to conventional open approaches. We describe a technique for mini-open spinal column shortening. Using intraoperative navigation pedicle screws were placed at T10, T11, L1, and L2. A mini-open 3-column "egg shell" decancellation osteotomy of T12 was performed through a transpedicular approach with preservation of the superior and inferior endplates. This procedure was performed on a 28year old male with recurrent TCS and neurogenic bladder. Postoperative imaging showed a reduction in spinal column length of 1.5cm and evidence of decreased tension on the spinal cord. At last follow-up he was recovering well with improved urinary function. Spinal column shortening for adult TCS can be safely achieved through a mini-open approach. Future studies should compare the efficacy of this technique to both traditional de-tethering and open spinal column shortening. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Mini-Sosie - a new concept in high-resolution seismic surveys

    Energy Technology Data Exchange (ETDEWEB)

    Wiles, C J

    1977-12-01

    Mini-Sosie is a new approach to high-resolution reflection seismics using a nondynamite source. The basic principles is to use an ordinary earth tamper to produce a long duration pseudo-random input pulse train. Returning signals from suitable geophone arrays are decoded in real time by crosscorrelation with the reference signal recorded from a source-sensor attached to the tamper plate. Relatively weak signals are stacked until sufficient amplitude is obtained; most noise is phased out during the decoding process while in-phase seismic events are added, resulting in good signal-to-noise ratios. The resulting output is the standard field seismogram. The source is relatively quiet and surface damage is insignificant thereby avoiding environmental restrictions. Mini-Sosie is especially useful for shallow investigation to one second (two-way time) and has a wide range of applications from shallow oil and gas exploration, coal, and hard mineral exploration to hydrology and engineering studies.

  16. Pulmonary vein isolation using the Rhythmia mapping system: Verification of intracardiac signals using the Orion mini-basket catheter.

    Science.gov (United States)

    Anter, Elad; Tschabrunn, Cory M; Contreras-Valdes, Fernando M; Li, Jianqing; Josephson, Mark E

    2015-09-01

    During pulmonary vein isolation (PVI), a circular lasso catheter is positioned at the junction between the left atrium (LA) and the pulmonary vein (PV) to confirm PVI. The Rhythmia mapping system uses the Orion mini-basket catheter with 64 electrodes instead of the lasso catheter. However, its feasibility to determine PVI has not been studied. The purpose of this study was to compare signals between the mini-basket and lasso catheters at the LA-PV junction. In 12 patients undergoing PVI using Rhythmia, the mini-basket and lasso catheters were placed simultaneously at the LA-PV junction for baseline and post-PVI signal assessment. Pacing from both catheters was performed to examine the presence of exit block. At baseline, recordings of LA and PV potentials were concordant in all PVs. However, after PVI, concordance between the catheters was only 68%. Discordance in all cases resulted from loss of PV potentials on the lasso catheter with persistence of PV potentials on the mini-basket catheter. In 9 of 13 PVs (69%), these potentials represented true PV potentials that were exclusively recorded with the smaller and closely spaced mini-basket electrodes. In the other 4 PVs (31%), these potentials originated from neighboring structures and resulted in underestimation of PVI. The use of the mini-basket catheter alone is sufficient to determine PVI. While it improves recording of PV potentials after incomplete ablation, it is also associated with frequent recording of "PV-like" potentials originating from neighboring structures. In these cases, pacing maneuvers are helpful to determine PVI and avoid excessive ablation. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  17. The Crystal Structure of a Maxi/Mini-Ferritin Chimera Reveals Guiding Principles for the Assembly of Protein Cages

    Energy Technology Data Exchange (ETDEWEB)

    Cornell, Thomas A. [Department; Division; Srivastava, Yogesh [Genome; Jauch, Ralf [Genome Institute of Singapore, Singapore; Genome; Fan, Rongli [Division; Orner, Brendan P. [Department; Division

    2017-07-19

    Cage proteins assemble into nanoscale structures with large central cavities. They play roles, including those as virus capsids and chaperones, and have been applied to drug delivery and nanomaterials. Furthermore, protein cages have been used as model systems to understand and design protein quaternary structure. Ferritins are ubiquitous protein cages that manage iron homeostasis and oxidative damage. Two ferritin subfamilies have strongly similar tertiary structure yet distinct quaternary structure: maxi-ferritins normally assemble into 24-meric, octahedral cages with C-terminal E-helices centered around 4-fold symmetry axes, and mini-ferritins are 12-meric, tetrahedral cages with 3-fold axes defined by C-termini lacking E-domains. To understand the role E-domains play in ferritin quaternary structure, we previously designed a chimera of a maxi-ferritin E-domain fused to the C-terminus of a mini-ferritin. The chimera is a 12-mer cage midway in size between those of the maxi- and mini-ferritin. The research described herein sets out to understand (a) whether the increase in size over a typical mini-ferritin is due to a frozen state where the E-domain is flipped out of the cage and (b) whether the symmetrical preference of the E-domain in the maxi-ferritin (4-fold axis) overrules the C-terminal preference in the mini-ferritin (3-fold axis). With a 1.99 Å resolution crystal structure, we determined that the chimera assembles into a tetrahedral cage that can be nearly superimposed with the parent mini-ferritin, and that the E-domains are flipped external to the cage at the 3-fold symmetry axes.

  18. PAX6 MiniPromoters drive restricted expression from rAAV in the adult mouse retina

    Directory of Open Access Journals (Sweden)

    Jack W Hickmott

    2016-01-01

    Full Text Available Current gene therapies predominantly use small, strong, and readily available ubiquitous promoters. However, as the field matures, the availability of small, cell-specific promoters would be greatly beneficial. Here we design seven small promoters from the human paired box 6 (PAX6 gene and test them in the adult mouse retina using recombinant adeno-associated virus. We chose the retina due to previous successes in gene therapy for blindness, and the PAX6 gene since it is: well studied; known to be driven by discrete regulatory regions; expressed in therapeutically interesting retinal cell types; and mutated in the vision-loss disorder aniridia, which is in need of improved therapy. At the PAX6 locus, 31 regulatory regions were bioinformatically predicted, and nine regulatory regions were constructed into seven MiniPromoters. Driving Emerald GFP, these MiniPromoters were packaged into recombinant adeno-associated virus, and injected intravitreally into postnatal day 14 mice. Four MiniPromoters drove consistent retinal expression in the adult mouse, driving expression in combinations of cell-types that endogenously express Pax6: ganglion, amacrine, horizontal, and Müller glia. Two PAX6-MiniPromoters drive expression in three of the four cell types that express PAX6 in the adult mouse retina. Combined, they capture all four cell types, making them potential tools for research, and PAX6-gene therapy for aniridia.

  19. PAX6 MiniPromoters drive restricted expression from rAAV in the adult mouse retina.

    Science.gov (United States)

    Hickmott, Jack W; Chen, Chih-Yu; Arenillas, David J; Korecki, Andrea J; Lam, Siu Ling; Molday, Laurie L; Bonaguro, Russell J; Zhou, Michelle; Chou, Alice Y; Mathelier, Anthony; Boye, Sanford L; Hauswirth, William W; Molday, Robert S; Wasserman, Wyeth W; Simpson, Elizabeth M

    2016-01-01

    Current gene therapies predominantly use small, strong, and readily available ubiquitous promoters. However, as the field matures, the availability of small, cell-specific promoters would be greatly beneficial. Here we design seven small promoters from the human paired box 6 (PAX6) gene and test them in the adult mouse retina using recombinant adeno-associated virus. We chose the retina due to previous successes in gene therapy for blindness, and the PAX6 gene since it is: well studied; known to be driven by discrete regulatory regions; expressed in therapeutically interesting retinal cell types; and mutated in the vision-loss disorder aniridia, which is in need of improved therapy. At the PAX6 locus, 31 regulatory regions were bioinformatically predicted, and nine regulatory regions were constructed into seven MiniPromoters. Driving Emerald GFP, these MiniPromoters were packaged into recombinant adeno-associated virus, and injected intravitreally into postnatal day 14 mice. Four MiniPromoters drove consistent retinal expression in the adult mouse, driving expression in combinations of cell-types that endogenously express Pax6: ganglion, amacrine, horizontal, and Müller glia. Two PAX6-MiniPromoters drive expression in three of the four cell types that express PAX6 in the adult mouse retina. Combined, they capture all four cell types, making them potential tools for research, and PAX6-gene therapy for aniridia.

  20. Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques.

    Science.gov (United States)

    Nakamichi, Ken-ichi; Tachibana, Shintaro; Yamamoto, Seizo; Ida, Masayoshi

    2010-03-01

    To compare the outcomes of percutaneous carpal tunnel release (PCTR) and mini-open carpal tunnel release (mini-OCTR) using ultrasonographic guidance for both techniques. We included 74 hands of 65 women with idiopathic carpal tunnel syndrome (age, 52-71 y; mean, 58 y). Thirty-five hands of 29 women had the PCTR (release with a device consisting of an angled blade, guide, and holder, along a line midway between the median nerve and ulnar artery (safe line) under ultrasonography (incision, 4 mm), and 39 hands of 36 women had the mini-OCTR (release along the safe line, distally under direct vision (incision, 1-1.5 cm) and proximally under ultrasonography, using a device consisting of a basket punch and outer tube. Assessments at 3, 6, 13, 26, 52, and 104 weeks showed no significant differences in neurologic recovery between the groups (p > .05). The PCTR group had significantly less pain, greater grip and key-pinch strengths, and better satisfaction scores at 3 and 6 weeks (p < .05), and less scar sensitivity at 3, 6, and 13 weeks (p < .05). There were no complications. The PCTR provides the same neurologic recovery as does the mini-OCTR. The former leads to less postoperative morbidity and earlier functional return and achievement of satisfaction. Therapeutic III. Copyright 2010. Published by Elsevier Inc.