WorldWideScience

Sample records for mini palmary incision

  1. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  2. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  3. Early response of local steroid injection versus mini incision technique in treatment of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Awan, A.S.; Khan, A.; Afridi, S.A.; Khan, R.S.

    2015-01-01

    Carpal tunnel syndrome Carpal tunnel syndrome (CTS) is one of the commonest peripheral neuropathies which effects mainly middle aged women. Different techniques are being tried to decrease the post-operative pain in patients operated for CTS. The objective of this study was to compare effectiveness of local injection of steroid and mini incision technique in the treatment of carpal tunnel syndrome. Methods: This randomized control trial was conducted at department of Orthopedics and department of Neurosurgery, Ayub Teaching Hospital, Abbottabad from Aug 2011 to Feb 2013. A total of 116 patients of CTS were randomly allocated to either of the two groups. Fifty-eight Patient in Group A were subjected to local steroid injection and the same number of patient in Group B underwent mini incision technique. All patients of were advised to report to the OPD after one month to determine intervention effectiveness in terms of improvement in at least one grade of pain. Results: In this study mean age of the patients was 32.8 ± 5.1 years. Female gender was in dominance with 99 (86.3%) cases. In this study we compared the effectiveness of local steroid injection and mini incision technique in the treatment of carpel tunnel syndrome. We found out that the steroid injection was effective in 69.0% cases while mini incision technique was effective in 56.9% cases. The difference being statistically insignificant with a p-value of 0.17. Conclusion: The difference in pain after 1 month of the intervention was not statistically significant. (author)

  4. Results of computer assisted mini-incision subvastus approach for total knee arthroplasty.

    Science.gov (United States)

    Turajane, Thana; Larbpaiboonpong, Viroj; Kongtharvonskul, Jatupon; Maungsiri, Samart

    2009-12-01

    Mini-incision subvastus approach is soft tissue preservation of the knee. Advantages of the mini-incision subvastus approach included reduced blood loss, reduced pain, self rehabilitation and faster recovery. However, the improved visualization, component alignment, and more blood preservation have been debatable to achieve the better outcome and preventing early failure of the Total Knee Arthroplasty (TKA). The computer navigation has been introduced to improve alignment and blood loss. The purpose of this study was to evaluate the short term outcomes of the combination of computer assisted mini-incision subvastus approach for Total Knee Arthroplasty (CMS-TKA). A prospective case series of the initial 80 patients who underwent computer assisted mini-incision subvastus approach for CMS-TKA from January 2007 to October 2008 was carried out. The patients' conditions were classified into 2 groups, the simple OA knee (varus deformity was less than 15 degree, BMI was less than 20%, no associated deformities) and the complex deformity (varus deformity was more than 15 degrees, BMI more was than 20%, associated with flexion contractor). There were 59 patients in group 1 and 21 patients in group 2. Of the 80 knees, 38 were on the left and 42 on the right. The results of CMS-TKA [the mean (range)] in group 1: group 2 were respectively shown as the incision length [10.88 (8-13): 11.92 (10-14], the operation time [118 (111.88-125.12): 131 (119.29-143.71) minutes, lateral releases (0 in both groups), postoperative range of motion in flexion [94.5 (90-100): 95.25 (90-105) degree] and extension [1.75 (0-5): 1.5 (0-5) degree] Blood loss in 24 hours [489.09 (414.7-563.48): 520 (503.46-636.54) ml] and blood transfusion [1 (0-1) unit? in both groups], Tibiofemoral angle preoperative [Varus = 4 (varus 0-10): Varus = 17.14 (varus 15.7-18.5) degree, Tibiofemoral angle postoperative [Valgus = 1.38 (Valgus 0-4): Valgus = 2.85 (valgus 2.1-3.5) degree], Tibiofemoral angle outlier (85% both

  5. Palmaris Longus Muscle in the South Indian Population – A Cadaveric Study

    Directory of Open Access Journals (Sweden)

    Lydia S. Quadros

    2017-07-01

    Full Text Available Introduction: Palmaris longus, one of the superficial flexor muscles of the anterior compartment of the forearm is the most variable muscle of the upper limb. Purpose: To note the variations of palmaris longus for tendon grafts. Methods: Forty formalin-fixed upper limb specimens of South Indian population were dissected to note the variations of Palmaris longus muscle. Results: Out of the forty upper limb specimens, two variants of the palmaris longus were noted. In one specimen, a reversed palmaris longus was noted. It had a long tendinous origin with a muscle belly and a short flat tendon at insertion. The tendon inserted partly into the flexor retinaculum and partly into palmar aponeurosis. In another specimen, apart from the normal palmaris longus muscle, an additional smaller muscle was noted. It was the Palmaris profundus. This muscle took origin in the form of a tendon from the middle of the shaft of the radius, continued as a muscle belly and then terminated as a tendon which later inserted into the flexor retinaculum, close to the tendon of palmaris longus muscle. At its insertion, the superficial palmar branch of radial artery hooked it. The anterior interosseous nerve supplied the Palmaris profundus. Conclusion: These variations are worthy to be noted for tendon grafts.

  6. Negative Suction Drain Through a Mini Periareolar Incision for the Treatment of Lactational Breast Abscess Shortens Hospital Stay and Increases Breastfeeding Rates.

    Science.gov (United States)

    Wei, Jinli; Zhang, Jiaxin; Fu, Deyuan

    2016-06-01

    Although breast abscess is a serious uncommon complication of mastitis with high morbidity rate, there is a lack of high-quality randomized trial to demonstrate the best treatments. We reported a novel way of applying negative suction drain through a mini periareolar incision. We retrospectively analyzed and compared the clinical characteristics of 62 patients with lactational breast abscess in our department from August 2012 to April 2015. Thirty-two patients went through traditional incision and drainage (Group A) and 30 patients were placed on negative suction drain through mini periareolar incision (Group B). There is no significant difference between the two groups in terms of age, white blood cell (WBC) count, size of the abscess cavity, and positive rate of Staphylococcus aureus (SA) or methicillin-resistant Staphylococcus aureus (MRSA). Patients in Group B had a shorter hospitalized stay (p = 0.003) and had a higher rate of continuation of breastfeeding (p breast abscess and maintaining breastfeeding.

  7. Anatomy and variations of palmaris longus in fetuses.

    Science.gov (United States)

    Albay, S; Kastamoni, Yadigar; Sakalli, Büşra; Tunali, S

    2013-01-01

    The aim of this study was to assess the absence of the palmaris longus, the proportion of the lengths of tendon and muscle belly, the development of the tendon and the belly during the fetal period, look for any difference between sides and gender. Fifty-eight spontaneously aborted human fetuses (26 female, 32 male, 116 upper extremities) were studied. The presence or absence of the palmaris longus was determined. The lengths of the belly and tendon were measured, and belly/tendon length ratio was calculated. Correlation with gestational age, body side and gender were studied. The muscle was absent in 44 forearms (37.93%; 20 right side, 34.48%; 24 left side, 41.38%); being bilateral in 19 of 58 fetuses (32.76%) and unilateral in six (10.34%). The unilateral absence rate was higher on the left side with a statistically significant difference. The absence of palmaris longus was more common in females, and the difference was statistically significant. The belly/tendon length ratio was 1.04 ± 0.35 on the right side and 1.09 ± 0.3 on the left. It did not show any difference according the fetal age. A sound knowledge on the anatomy and variations of palmaris longus is of great importance during surgical interventions; because it is the first choice for tendon grafts, by the virtue of its structure and function. Thus, this study is of academic interest for anatomists and hand surgeons alike.

  8. Treatment of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision: experience with 31 cases.

    Directory of Open Access Journals (Sweden)

    Jun Shi

    Full Text Available Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm. No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes.

  9. Variant palmaris profundus enclosed by an unusual loop of the median nerve

    Science.gov (United States)

    CHOU, HSIU-CHU; JENG, HELLEN; KO, TSUI-LING; PAI, MAN-HUI; CHANG, CHIU-YUN; WU, CHING-HSIANG

    2001-01-01

    According to the usual description in most anatomy texts, the median nerve in the forearm passes between the 2 heads of pronator teres. It continues distally between flexor digitorum superficialis and profundus almost to the retinaculum. Muscular branches leave the nerve near the elbow and supply all superficial muscles of the anterior part of the forearm except flexor carpi ulnaris. Many variations of the median nerve in the forearm have been reported (Urban & Krosman, 1992). The palmaris profundus is also a rare anomaly of the forearm (Dyreby & Engber, 1982). It originates from the radial side of the common flexor tendon in the proximal forearm and inserts into the undersurface of the palmar aponeurosis. The origin of palmaris profundus may be close to the median nerve and its branches, and may be involved in compressive neuropathy of the anterior interosseous nerve. Its tendon crossing through the carpal canal has been implicated in the carpal tunnel syndrome (reviewed by Lahey & Aulicino, 1986). In some cases, palmaris profundus was found enclosed in a common fascial sheath with the median nerve (Stark, 1992; Sahinoglu et al. 1994). To indicate its close association with the median nerve, the palmaris profundus was also named ‘musculus comitans nervi mediani’ (Sahinoglu et al. 1994). This article reports an unusual loop of the median nerve encircling an anomalous palmaris profundus in the forearm, which, to the best of our knowledge, has not been previously described. PMID:11693311

  10. A single incision transaxillary thoracoscopic sympathectomy

    Directory of Open Access Journals (Sweden)

    Marić Nebojša

    2014-01-01

    Full Text Available Background/Aim. Primary hyperhidrosis causes are unknown. The disorder begins in early childhood. It intensifies in puberty and maturity. It is equally present in both sexes. The symptoms exacerbate when the body temperature rises and due to emotional stimuli affecting the sympathetic nerve system. The aim of this study was to demonstrate that videoassisted thoracoscopic surgery (VATS sympathectomy is a method for primary focal hyperhidrosis permanent treatment. The single incision method in properly selected patients maximizes the intervention effectiveness and minimizes aesthetic side effects. Methods. This prospective study analysed the findings in patients who had been operated on due to primary focal hyperhidrosis (face, palms, and armpits using a single small transaxilarry incision in the third inter-rib space at the level of the anterior axillary line with two 5 mm flexible ports. All the patients, with T2-T5 thoracoscopic sympathectomy of the sympathetic chain using a single small incision in the third inter-rib space in the anterior axillary line, were analysed in the period from September 2009 to November 2010 regarding the postoperative morbidity and outcomes of the operation (clinical evaluation and visual analogue scale with a view to assessing the effectiveness of the surgery conducted in this manner. Results. A total of 47 patients (18 men, 29 women, 18 to 48 years old (29 on average had underwent 94 bilateral video-assisted thoracoscopic sympathectomies. The sympathectomy was indicated in cases of facial blushing and sweating (6.38%, palmary sweating (34.04%, axillary sweating (14.89% or both palmary and axillary sweating (44.68%. The largest percentage of patients (98.6% had left the hospital the following day. The postoperative 30 day’s mortality was 0 and the conversion into open surgery was not necessary. As for complications, there had been an occurrence of partial pneumothorax in two patients treated by means of

  11. A Study on the Absence of Palmaris Longus in a Multi- racial Population

    Directory of Open Access Journals (Sweden)

    SA Roohi

    2007-05-01

    Full Text Available Palmaris longus is a dispensable muscle with a long tendon which is very useful in reconstructive surgery. It is absent 2.8 to 24% of the population depending on the race/ethnicity studied. Four hundred and fifty healthy subjects (equally distributed among Malaysia’s 3 major ethnic groups were clinically examined for the presence or absence of palmaris longus. This tendon was found to be absent unilaterally in 6.4% of study subjects, and bilaterally in 2.9% of study participants. Malays have a high prevalence of palmaris longus absence at 11.3% followed closely by Indians at 10.7% whilst Chinese had a low absence rate of 6.0%.

  12. Assessment of the presence/absence of the palmaris longus muscle in different sports, and elite and non-elite sport populations.

    Science.gov (United States)

    Fowlie, Craig; Fuller, Colin; Pratten, Margaret K

    2012-06-01

    To investigate whether higher presence of the palmaris longus muscle is associated with sports that require hand grip. Cross-sectional study. Six hundred and forty-two medical students, members of sports clubs and national athletes. Participants were invited to complete a questionnaire that assessed their main sport, elite or non-elite level of participation, and level of activity. The presence of the palmaris longus was assessed visually using a standardised test. Presence of the palmaris longus, type of hand grip required for the sport and the level of participation. The presence of the palmaris longus was higher in elite athletes (21/22, 96%) than non-elite athletes (66/84, 79%; P=0.066) for sports that require a dominant-handed or two-handed cylindrical grip (18/22, 82% and 19/35, 54%, respectively; P=0.034). For both elite and non-elite athletes, the presence of the palmaris longus was higher in those participating in sustained grip sports (325/387, 84%) compared with sports that do not require a sustained grip (150/197, 76%; P=0.012). The palmaris longus may provide an advantage in certain types of sport that require hand grip, and for elite athletes participating in sports that require a dominant-handed or two-handed cylindrical hand grip. Orthopaedic specialists considering the use of the palmaris longus for a grafting procedure on an athlete should consider the level of participation and the type of hand grip required in the athlete's sport. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  13. Morphometric and Statistical Analysis of the Palmaris Longus Muscle in Human and Non-Human Primates

    Science.gov (United States)

    Aversi-Ferreira, Roqueline A. G. M. F.; Bretas, Rafael Vieira; Maior, Rafael Souto; Davaasuren, Munkhzul; Paraguassú-Chaves, Carlos Alberto; Nishijo, Hisao; Aversi-Ferreira, Tales Alexandre

    2014-01-01

    The palmaris longus is considered a phylogenetic degenerate metacarpophalangeal joint flexor muscle in humans, a small vestigial forearm muscle; it is the most variable muscle in humans, showing variation in position, duplication, slips and could be reverted. It is frequently studied in papers about human anatomical variations in cadavers and in vivo, its variation has importance in medical clinic, surgery, radiological analysis, in studies about high-performance athletes, in genetics and anthropologic studies. Most studies about palmaris longus in humans are associated to frequency or case studies, but comparative anatomy in primates and comparative morphometry were not found in scientific literature. Comparative anatomy associated to morphometry of palmaris longus could explain the degeneration observed in this muscle in two of three of the great apes. Hypothetically, the comparison of the relative length of tendons and belly could indicate the pathway of the degeneration of this muscle, that is, the degeneration could be associated to increased tendon length and decreased belly from more primitive primates to those most derivate, that is, great apes to modern humans. In conclusion, in primates, the tendon of the palmaris longus increase from Lemuriformes to modern humans, that is, from arboreal to terrestrial primates and the muscle became weaker and tending to be missing. PMID:24860810

  14. Morphometric and Statistical Analysis of the Palmaris Longus Muscle in Human and Non-Human Primates

    Directory of Open Access Journals (Sweden)

    Roqueline A. G. M. F. Aversi-Ferreira

    2014-01-01

    Full Text Available The palmaris longus is considered a phylogenetic degenerate metacarpophalangeal joint flexor muscle in humans, a small vestigial forearm muscle; it is the most variable muscle in humans, showing variation in position, duplication, slips and could be reverted. It is frequently studied in papers about human anatomical variations in cadavers and in vivo, its variation has importance in medical clinic, surgery, radiological analysis, in studies about high-performance athletes, in genetics and anthropologic studies. Most studies about palmaris longus in humans are associated to frequency or case studies, but comparative anatomy in primates and comparative morphometry were not found in scientific literature. Comparative anatomy associated to morphometry of palmaris longus could explain the degeneration observed in this muscle in two of three of the great apes. Hypothetically, the comparison of the relative length of tendons and belly could indicate the pathway of the degeneration of this muscle, that is, the degeneration could be associated to increased tendon length and decreased belly from more primitive primates to those most derivate, that is, great apes to modern humans. In conclusion, in primates, the tendon of the palmaris longus increase from Lemuriformes to modern humans, that is, from arboreal to terrestrial primates and the muscle became weaker and tending to be missing.

  15. Presence of Multiple Tendinous Insertions of Palmaris Longus: A ...

    African Journals Online (AJOL)

    Case Details: We report here a unique case of palmaris longus presenting variation distally as its tendon divides to gain multiple attachments with the fascia covering the abductor pollicis brevis, flexor retinaculum and the tendon of flexor carpi ulnaris. In addition, it also continues as palmar aponeurosis as its normal course.

  16. Clinical Assessment of the Palmaris Longus – Accuracy of common ...

    African Journals Online (AJOL)

    tending the orthopaedic surgical outpatient clinic. The subjects were recruited consecutively and subjected to 10 tests to detect the presence of the Palmaris Longus. The patients were examined by a resident in orthopaedics as- sisted by two students of clinical medicine (equivalent of physician assistant) who had all been ...

  17. Reversed Palmaris Longus Muscle Causing Volar Forearm Pain and Ulnar Nerve Paresthesia.

    Science.gov (United States)

    Bhashyam, Abhiram R; Harper, Carl M; Iorio, Matthew L

    2017-04-01

    A case of volar forearm pain associated with ulnar nerve paresthesia caused by a reversed palmaris longus muscle is described. The patient, an otherwise healthy 46-year-old male laborer, presented after a previous unsuccessful forearm fasciotomy for complaints of exercise exacerbated pain affecting the volar forearm associated with paresthesia in the ulnar nerve distribution. A second decompressive fasciotomy was performed revealing an anomalous "reversed" palmaris longus, with the muscle belly located distally. Resection of the anomalous muscle was performed with full relief of pain and sensory symptoms. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Resistência mecânica do ligamento patelar após a retirada do terço médio com incisão longitudinal ou duas mini-incisões transversas Patellar ligament strength after removal of the middle-third through either one longitudinal incision or two mini-transverse incisions

    Directory of Open Access Journals (Sweden)

    Leandro Calil De Lazari

    2010-01-01

    Full Text Available OBJETIVO: Avaliar a resistência e a regeneração do ligamento patelar após a retirada de enxerto para reconstrução do ligamento cruzado anterior, utilizando a técnica tradicional de incisão na pele única longitudinal e uma técnica de duas mini-incisões transversas, em ovinos. MÉTODOS: Foram utilizadas 10 ovelhas. No joelho direito, realizamos a retirada do enxerto do ligamento patelar através do método tradicional e, no joelho esquerdo, através do método de duas incisões. Os animais ficaram em observação por seis meses. O conjunto (ligamento patelar, tíbia e a patela foi adaptado à máquina de testes mecânicos para testes de resistência do ligamento. RESULTADOS: Não foi encontrada diferença entre as duas técnicas propostas com relação à regeneração e resistência do ligamento patelar. Observamos, porém, o encurtamento do ligamento patelar nos dois grupos, e que a sutura da fascia superficialis do ligamento patelar não influiu na regeneração do ligamento patelar, segundo a histologia. CONCLUSÃO: A técnica utilizando duas incisões na pele apresenta os mesmos padrões de regeneração e resistência do ligamento patelar remanescente, quando comparada à técnica tradicional de incisão única longitudinal.OBJECTIVE: To evaluate the mechanical strength and regeneration of the patellar ligament after harvesting the middle-third for reconstruction of the anterior cruciate ligament, using the traditional technique of a single longitudinal skin incision or two small transverse incisions, in sheep. METHODS: Ten sheep were used in this study. In the right knee we removed the graft by the traditional method, and in the left knee, using the two transverse incision method. The animals were observed for six months. The specimens (patellar, tibia and patella were adapted to the mechanical test machine. RESULTS: No difference was found between the two proposed techniques in relation to regeneration and mechanical strength of

  19. The inverted Batman incision: a new incision in transcolumellar incision for open rhinoplasty.

    Science.gov (United States)

    Nakanishi, Yuji; Nagasao, Tomohisa; Shimizu, Yusuke; Miyamoto, Junpei; Fukuta, Keizo; Kishi, Kazuo

    2013-12-01

    Columellar and nostril shapes often present irregularity after transcolumellar incision for open rhinoplasty, because of the contracture of the incised wound. The present study introduces a new technique to prevent this complication, and verifies its efficacy in improving cosmetic appearance. In our new method, a zig-zag incision with three small triangular flaps is made on the columella and in the pericolumellar regions of the bilateral nostril rims. Since the shape of the incision resembles the contour of an inverted "batman", we term our new method the "Inverted Batman" incision. To verify the effectiveness of the Inverted Batman incision, aesthetic evaluation was conducted for 21 patients operated on using the conventional transcolumellar incision (Conventional Group) and 19 patients operated on using the Inverted Batman incision (Inverted Batman Group). The evaluation was performed by three plastic surgeons, using a four-grade scale to assess three separate items: symmetry of bilateral soft triangles, symmetry of bilateral margins of the columella, and evenness of the columellar surface. The scores of the two groups for these three items were compared using a non-parametric test (Mann-Whitney U-test). With all three items, the Inverted Batman group patients present higher scores than Conventional Group patients. The Inverted Batman incision is effective in preserving the correct anatomical structure of the columella, soft triangle, and nostril rims. Hence, we recommend the Inverted Batman incision as a useful technique for open rhinoplasty.

  20. Reconstruction of large defects of the lips and commissure using a composite radial forearm palmaris longus free flap associated with a lengthening temporalis myoplasty.

    Science.gov (United States)

    Martin, Thomas; Sury, Florent; Goga, Dominique; Parmentier, Jerome; Rozen, Adam; Laure, Boris

    2012-08-01

    We performed a single-stage operation to reconstruct a large defect of the lips and commissure using a composite radial forearm-palmaris longus free flap. To obtain cranial traction and a voluntary smile, independently from any jaw movement, traction was achieved by using a lengthening temporalis myoplasty. The tendon attached to the coronoid process was fixed to the palmaris longus tendon, recreating a new commissure and a "neo-modiolus." Physical therapy was started on the 21st postoperative day to facilitate progress from a "mandibular smile," to ideally a spontaneous and symmetric smile after 3 months of therapy. This procedure was able to obtain good oral continence and a good commissural movement during smile which has not previously been mentioned in the published literature.

  1. Palmaris Longus Muscle’s Prevalence in Different Nations and Interesting Anatomical Variations: Review of the Literature

    OpenAIRE

    Ioannis, Dimitriou; Anastasios, Katsourakis; Konstantinos, Natsis; Lazaros, Kostretzis; Georgios, Noussios

    2015-01-01

    The prevalence of the palmaris longus (PL) muscle varies more than any other muscle in the human body. Its absence across the world ranges between 1.5% and 63.9%. It presents with many different anomalies, discovered either clinically, intraoperatively or after anatomical examination of cadavers. This paper includes recent studies and reports about the presence and variations of the PL muscle, thereby illustrating the differences between ethnic groups, as well as emphasizing the different way...

  2. Palmaris Longus Muscle's Prevalence in Different Nations and Interesting Anatomical Variations: Review of the Literature.

    Science.gov (United States)

    Ioannis, Dimitriou; Anastasios, Katsourakis; Konstantinos, Natsis; Lazaros, Kostretzis; Georgios, Noussios

    2015-11-01

    The prevalence of the palmaris longus (PL) muscle varies more than any other muscle in the human body. Its absence across the world ranges between 1.5% and 63.9%. It presents with many different anomalies, discovered either clinically, intraoperatively or after anatomical examination of cadavers. This paper includes recent studies and reports about the presence and variations of the PL muscle, thereby illustrating the differences between ethnic groups, as well as emphasizing the different ways of finding it, during daily clinical and surgical practice.

  3. Mini-Open Latarjet Procedure for Recurrent Anterior Shoulder Instability

    Directory of Open Access Journals (Sweden)

    Numa Mercier

    2011-01-01

    Full Text Available Anterior shoulder instability is a common problem. The Latarjet procedure has been advocated as an option for the treatment of anteroinferior shoulder instability. The purpose of this paper is to explain our surgical procedure titled “Mini-open Latarjet Procedure.” We detailed patient positioning, skin incision, subscapularis approach, and coracoid fixation. Then, we reviewed the literature to evaluate the clinical outcomes of this procedure.

  4. Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques.

    Science.gov (United States)

    Nakamichi, Ken-ichi; Tachibana, Shintaro; Yamamoto, Seizo; Ida, Masayoshi

    2010-03-01

    To compare the outcomes of percutaneous carpal tunnel release (PCTR) and mini-open carpal tunnel release (mini-OCTR) using ultrasonographic guidance for both techniques. We included 74 hands of 65 women with idiopathic carpal tunnel syndrome (age, 52-71 y; mean, 58 y). Thirty-five hands of 29 women had the PCTR (release with a device consisting of an angled blade, guide, and holder, along a line midway between the median nerve and ulnar artery (safe line) under ultrasonography (incision, 4 mm), and 39 hands of 36 women had the mini-OCTR (release along the safe line, distally under direct vision (incision, 1-1.5 cm) and proximally under ultrasonography, using a device consisting of a basket punch and outer tube. Assessments at 3, 6, 13, 26, 52, and 104 weeks showed no significant differences in neurologic recovery between the groups (p > .05). The PCTR group had significantly less pain, greater grip and key-pinch strengths, and better satisfaction scores at 3 and 6 weeks (p < .05), and less scar sensitivity at 3, 6, and 13 weeks (p < .05). There were no complications. The PCTR provides the same neurologic recovery as does the mini-OCTR. The former leads to less postoperative morbidity and earlier functional return and achievement of satisfaction. Therapeutic III. Copyright 2010. Published by Elsevier Inc.

  5. The fourth incision: a cosmetic autopsy incision technique.

    Science.gov (United States)

    Patowary, Amarjyoti

    2010-03-01

    Autopsy procedure includes thorough external examination as well as internal examination including opening of all the body cavities for proper visualization of all the visceral organs. As such, there remains incision marks with stitches which harts the sentiment of the already traumatized relatives of the deceased. Moreover, it looks odd especially in cases of otherwise healthy dead bodies. So, autopsy incisions should be such that, we can get maximum possible visualization of the body cavities, particularly the thorax and abdomen, and at the same time the incision as well as the stitch marks are also hidden. This article is aimed to describe few modifications in the autopsy incisions for opening the thorax and abdomen and also proper visualization of the neck structures during autopsy where the incisions and the stitches are kept hidden.

  6. Pedicled Descending Branch Latissimus Dorsi Mini-flap for Repairing Partial Mastectomy Defect: A New Technique

    Directory of Open Access Journals (Sweden)

    Ruizhao Cai, M.D.

    2018-03-01

    Full Text Available Summary:. Volume loss is 1 of the major factors influencing cosmetic outcomes of breast after partial mastectomy (PM, especially for smaller breasts, and therefore, volume replacement is critical for optimizing the final aesthetic outcome. We present a novel technique of raising a pedicled descending branch latissimus dorsi (LD mini-flap for reconstruction of PM defects via an axillary incision. After PM, the LD mini-flap is harvested through the existing axillary incision of the axillary dissection or the sentinel lymph node biopsy. The descending branches of thoracodorsal vessels and nerve are carefully identified and isolated. The transverse branches are protected to maintain muscle innervation and function. The LD muscle is then undermined posteriorly and inferiorly to create a submuscular pocket and a subcutaneous pocket between LD muscle and superficial fascia. Once the submuscular plane is created, the muscle is divided along the muscle fibers from the deep surface including a layer of fat above the muscle. Finally, the LD mini-flap is transferred to the breast defect. Given the limited length and mobility of the LD mini-flap, this approach is best utilized for lateral breast defects. However, for medial defects, the lateral breast tissue is rearranged to reconstruct the medial breast defect, and an LD mini-flap is then used to reconstruct the lateral breast donor site. This technique can therefore be employed to reconstruct all quadrants of the breast and can provide aesthetic outcomes without scars on the back, with minimal dysfunction of LD muscle.

  7. Soft tissue stabilization for palmar midcarpal instability using a palmaris longus tendon graft.

    Science.gov (United States)

    Chaudhry, Tahseen; Shahid, Mohammed; Wu, Feiran; Mishra, Anuj; Deshmukh, Subodh

    2015-01-01

    To report the results of a technique of soft tissue stabilization for palmar midcarpal instability using a palmaris longus graft. In patients' symptomatic wrists with palmar midcarpal instability that had failed conservative management, we used a dorsal approach and stabilized the hamate and triquetrum by reconstructing the dorsal triquetrohamate ligament. The palmaris longus tendon graft was fixed with bone anchors. Seven wrists in 6 patients were available for follow-up at a mean of 28 months (range, 17-37 mo). There was an overall meaningful improvement in function (mean preoperative Disabilities of the Arm, Shoulder, and Hand score, 49 preoperatively, 28 postoperatively). There was a significant increase in grip strength from 15 to 21 kg. At final follow-up, 2 patients had moderate pain. The others had mild or no pain. Four patients returned to their previous occupation or activity. Patients retained full pronation and supination. When compared with the normal side, flexion was reduced to 71%, extension to 81%, radial deviation to 90%, and ulnar deviation to 65% of the opposite side. Although the mean results show an improvement, one patient had a poor result with deterioration in Disabilities of the Arm, Shoulder, and Hand score in spite of a clinically stable wrist, and another had clinical evidence of recurrent instability during pregnancy. One patient had residual symptoms from a prominent bone anchor. Overall, this technique showed good medium-term results in most of our patients. It retained some midcarpal mobility, eliminated clunking in most patients, and provided a noteworthy improvement in grip strength and function. We continue to use this technique for patients with symptomatic midcarpal instability, but it requires further evaluation with larger patient numbers and a longer follow-up to assess its overall value. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Transconjunctival incision for total maxillectomy--an alternative for subciliary incision.

    Science.gov (United States)

    Goyal, Amit; Tyagi, Isha; Jain, Shilpa; Syal, Rajan; Singh, Alok Pratap; Kapila, Rajeev

    2011-09-01

    A subciliary incision may be associated with various complications of the lower eyelid when it is used during a total maxillectomy. The use of the transconjunctival incision instead is an alternative in suitable patients. The records of 17 patients were reviewed in whom a transconjunctival incision was used during total maxillectomy. These included 13 in whom the Weber-Ferguson incision was used, and 4 who had a sublabial incision. There was mild conjunctival oedema in all the cases during the immediate postoperative period but it did not last for more than two days. Four patients had mild to moderate oedema of the lid that resolved within two days. One had mild ectropion with transient epiphora, which was caused by early removal of the medial canthal sutures. We found the approach to be cosmetically acceptable as it avoids a scar in the subciliary region. The transconjunctival incision can be used in place of the subciliary incision for lateral exposure during total maxillectomy. There are few complications associated with the lower lid, and it has good cosmetic results; if it is combined with a sublabial incision in suitable patients, the maxillectomy is virtually scar-free. Copyright © 2010 British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Arc-to-arc mini-sling 1999: a critical analysis of concept and technology

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2011-04-01

    Full Text Available PURPOSE: The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique a less invasive mid-urethral sling using bovine pericardium as the sling material. MATERIALS AND METHODS: The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. RESULTS: The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. CONCLUSION: The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.

  10. Chronic triceps insufficiency managed with extensor carpi radialis longus and palmaris longus tendon grafts.

    Science.gov (United States)

    Singh, Dhanpal; Kumar, K Arun; Dinesh, Mc; Raj, Ranju

    2012-03-01

    Chronic triceps insufficiency, causing prolonged disability, occurs due to a missed diagnosis of an acute rupture. We report a 25 year old male with history of a significant fall sustaining multiple injuries. Since then, he had inability in extending his right elbow for which he sought intervention after a year. Diagnosis of triceps rupture was made clinicoradiologically and surgery was planned. Intraoperative findings revealed a deficient triceps with a fleck of avulsed bone from olecranon. Ipsilateral double tendon graft including extensor carpi radialis longus and palmaris longus were anchored to triceps and secured with the olecranon. Six-months follow revealed a complete active extension of elbow and a full function at the donor site.

  11. Improvement of pustulosis palmaris et plantaris by periodontal infection control in a patient with chronic periodontitis.

    Science.gov (United States)

    Murai, Osamu; Sasaki, Daisuke; Ando, Yoshinori; Fujimura, Akira; Oikawa, Hiromi; Suwa, Nagisa; Watabe, Daisuke; Maeda, Fumihiko; Endo, Kohki; Yaegashi, Takashi; Akasaka, Toshihide; Naruishi, Koji

    2012-01-01

    Pustulosis palmaris et plantaris (PPP) is a chronic, inflammatory, autoimmune-type disease characterized by sterile pustules of skin. The skin inflammation is influenced by several factors such as drugs, sunlight, metabolic and psychogenic factors as well as metal allergy. Here, we report a rare case that intensive periodontal treatment might have contributed to the improvement of skin inflammation. Skin inflammation regressed 1 month after intensive periodontal treatment. Both CD4/CD8 ratio and % of B cells in the blood sample were slightly decreased corresponding to the improvement of periodontal inflammation. Infection control of periodontal lesions might be one of attractive therapeutic targets in management of PPP.

  12. The Prevalence of Palmaris longus agenesis among the Ghanaian population

    Directory of Open Access Journals (Sweden)

    Osonuga A

    2012-10-01

    Full Text Available Objective: Background: Studies have documented the agenesis of Palmaris longus muscle in different populations but none has included the Ghanaian population. Methods: The study involved 226 subjects (130 females and 96 males who are students of the University of Cape Coast, Cape Coast, Ghana. The presence of the PLM was clinically determined using the Schaeffer’s test. Subjects in which the tendon was not visualized or palpable, two other tests were performed to confirm the absence. Results: The total prevalence of absence of PLM was 3.1%; absence on the left hand was commoner than on the right hand. The frequency of PLM absence was also slightly higher in females than in males representing 1.8% and 1.3% respectively. One female had the PLM absent bilaterally whiles a male subject had a trifid tendon on the right forearm with a bifid on the left. Conclusion: The prevalence of PLM agenesis in the Ghanaian population is lower compared to values coated in standard textbook on surgery. PLM is not diminishing as fast as observed in some population hence it is can be readily used as donor tendon by Ghanaian surgeons.

  13. Is dermatitis palmaris sicca an irritant contact dermatitis?

    Science.gov (United States)

    Chen, Fu-Juan; Liu, Zhen; Zhou, Ying; Chen, Yong-Hua; Fan, Yi-Ming

    2013-01-01

    Dermatitis palmaris sicca (DPS) is a common dry-fissured palmar dermatitis in Asian women. It may be an irritant contact dermatitis, but the immunophenotype of the cells in its infiltrate is unknown. The aim of this study was to evaluate the role of inflammatory cells in the pathogenesis of DPS. Patch testing was done in 68 patients with DPS, 87 subjects with hand eczema, and 31 healthy subjects. Immunophenotyping of cutaneous inflammatory cells was performed in 8 patients with DPS, 10 subjects with hand eczema, and 8 healthy individuals. Positive patch rates were higher in patients with DPS and those with hand eczema compared with healthy controls, but strong positive (++ or +++) reactions in DPS were fewer compared with hand eczema. Density of CD3, CD4, CD8, and CD68 cells in skin lesions of DPS and hand eczema was significantly higher than that in normal skin. Sparse CD20 cells were present only in hand eczema. Compared with hand eczema, the number of CD3, CD8, CD68, and dermal CD1a cells decreased, but epidermal CD1a cells and CD4/CD8 ratio increased in DPS. The absolute lack of CD20 cells and relative scarcity of dermal CD8 and CD1a cells in skin lesions might be insufficient to induce contact hypersensitivity, so DPS may be an irritant but not allergic contact dermatitis.

  14. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery.

    Science.gov (United States)

    Jauhari, Nidhi; Chopra, Deepak; Chaurasia, Rajan Kumar; Agarwal, Ashutosh

    2014-01-01

    To determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS). A prospective cross sectional study was done on a total of 75 patients aged 40y and above with senile cataract. The patients were randomly divided into three groups (25 each). Each group received a particular type of incision (Straight, Frown or Inverted V shape incisions). Manual SICS with intraocular lens (IOL) implantation was performed. The patients were compared 4wk post operatively for uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA) and SIA. All calculations were performed using the SIA calculator version 2.1, a free software program. The study was analyzed using SPSS version 15.0 statistical analysis software. The study found that 89.5% of patients in Straight incision group, 94.2% in Frown incision group and 95.7% in Inverted V group attained BCVA post-operatively in the range of 6/6 to 6/18. Mean SIA was minimum (-0.88±0.61D×90 degrees) with Inverted V incision which was statistically significant. Inverted V (Chevron) incision gives minimal SIA.

  15. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  16. Mast Quadrant-assisted Minimally Invasive Modified Transforaminal Lumbar Interbody Fusion: Single Incision Versus Double Incision

    Directory of Open Access Journals (Sweden)

    Xin-Lei Xia

    2015-01-01

    Full Text Available Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate the clinical feasibility of Mast Quadrant-assisted modified transforaminal lumbar interbody fusion (TLIF with a small single posterior median incision. Methods: During the period of March 2011 to March 2012, 34 patients with single-segment degenerative lumbar disease underwent the minimally invasive modified TLIF assisted by Mast Quadrant with a small single posterior median incision (single incision group. The cases in this group were compared to 37 patients with single-segment degenerative lumbar disease in the double incision group. The perioperative conditions of patients in these two groups were statistically analyzed and compared. The Oswestry Disability Index (ODI scores, Visual Analog Scale (VAS scores, and sacrospinalis muscle damage evaluation indicators before operation and 3, 12 months postoperation were compared. Results: A total of 31 and 35 cases in the single incision and double incision groups, respectively, completed at least 12 months of systemic follow-up. The differences in perioperative conditions between the two groups were not statistically significant. The incision length of the single incision group was significantly shorter than that of the double incision group (P < 0.01. The ODI and VAS scores of patients in both groups improved significantly at 3 and 12 months postoperation. However, these two indicators at 3 and 12 months postoperation and the sacrospinalis muscle damage evaluation indicators at 3 months postoperation did not differ significantly between the two groups (P ≥ 0.05. Conclusions: Mast Quadrant-assisted modified TLIF with a small single posterior median incision has excellent clinical feasibility compared to minimally invasive TLIF with a double paramedian incision.

  17. Movimentação de molares inferiores ancorados em mini-parafusos Mandibular molar uprighting, using mini-screw as anchorage

    Directory of Open Access Journals (Sweden)

    Rosana Canteras Di Matteo

    2005-08-01

    posterior to the tooth. Three pacients with ages between 40 and 48 years old (two females and one male were selected. The three of them presented mesially tipped molars, positioned posterior to the edentulous areas, on both sides of the mandible. These patients received orthodontic treatment during a period of 6 and 12 months with the MD3 technique. Titanium mini-screws were positioned bilaterally, under local anesthesia. One incision with 1 cm was done in each side of the mandibular external oblique line, distally to the tipped molars. After that, the mini-screws were positioned and sutures were done, leaving the mini-screws heads exposed. After one week, orthodontic loads (between 150 and 200 grams/force were applied to the mini-screws through elastics. A certain degree of inflammation around the mini-screws was noticed, but it was controlled by hygienic procedure. This surgery procedure was simple and could be done easily by the orthodontist. The dimensions and shapes of the mini-screws proved to be appropriate and their removal after the orthodontic movement were done without difficulty. The result was time reduction on the molars uprighting, without side effects on the others teeth. The use of mini-screws seems to be a good alternative for an effective orthodontic anchorage on the uprighting mandibular molars.

  18. Comparison of electrocautery incision with scalpel incision in midline abdominal surgery - A double blind randomized controlled trial.

    Science.gov (United States)

    Prakash, Lalgudi Dorairajan; Balaji, Nitesh; Kumar, Sathasivam Suresh; Kate, Vikram

    2015-07-01

    To compare the electrocautery incision with scalpel incision in patients undergoing abdominal surgery using a midline incision with respect to incision time, blood loss during incision, postoperative incision site pain and wound infection. Patients undergoing midline abdominal surgery were randomized into electrocautery and scalpel groups. The incision dimensions, incision time and blood loss during incision were noted intraoperatively. Postoperative pain and wound infection were recorded on every postoperative day for one week. 41 patients in each of the two groups were analyzed. Gender and age distribution was similar in both the groups. The mean incision time per unit wound area in the electrocautery group and scalpel group was 9.40 ± 3.37 s/cm(2) and 9.07 ± 3.40 s/cm(2) (p = 0.87) respectively. The mean blood loss per unit wound area was significantly lower in the electrocautery group at 6.46 ± 3.94 ml when compared to that of 23.40 ± 15.28 ml in the scalpel group (p= electrocautery and scalpel groups (14.63% vs. 12.19%; p = 0.347). With a comparable Postoperative incision site pain, wound infection rate and significantly lower blood loss with the equal time taken for the incision, electrocautery can be considered safe and effective in making skin incision in midline laparotomy compared to scalpel incision. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  19. Microsurgical head and neck tissue repair by visceral mini-autografting

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available Objective. To minimize surgical trauma in patients with head and neck tumors during microsurgical plasty with visceral autografts.Subjects and methods. Clinical experience has been gained in the treatment of 53 patients with locally advanced craniofascial (n = 27 and oropharyngeal (n = 36 cancers. Abdominal organs were used for plastic closure of extensive defects after surgical resection. Paraumbilical incision allowing for an adequate approach into the abdominal cavity with minimal external trauma in the anterior abdominal wall was chosen as an access procedure. Video-assisted techniques were used to excise the midline aponeurosis. Donor organs, such as the omentum, greater curvature of the stomach, transverse colon, small intestine were taken through a mini-laparotomic incision to the anterior abdominal wall, then the vascular pedicle was exposed and a visceral autograft was made. After forming and cutting off the autograft, organ anastomoses were created extracorporeally.Results. Mini-access surgery could be completed in 50 of the 53 cases (4 patients had previously undergone abdominal interventions. Omental (n = 26, colo-omental (n = 15, gastro-omental (n = 7, and entero-omental (n = 5 flaps were made and prepared for autografting. No intra- or postoperative abdominal complications were found.Conclusion. Minimally invasive technologies used to create visceral authografts for head and neck tissue repair can minimize surgical trauma and reduce treatment duration. The indications for this access are the debilitating state of a cancer patient or the young age of a patient who does not wish to have an additional scar in the donor region.

  20. Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Directory of Open Access Journals (Sweden)

    Sengupta S

    2007-11-01

    Full Text Available Abstract Background Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. Hypothesis There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Study Design Controlled laboratory cadaveric study. Methods 54 cadaveric native (acromioclavicular and coracoclavicular ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1 in the intact states, 2 after modified Weaver-Dunn reconstruction (WD, 3 after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ, 4 after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP or 5 after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS and 6 after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt. Posterior-anterior (horizontal loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005. Results Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p WD.ACJ provided additional

  1. Craniosynostosis incision: scalpel or cautery?

    Science.gov (United States)

    Wood, Jeyhan S; Kittinger, Benjamin J; Perry, Victor L; Adenola, Adeyemi; van Aalst, John A

    2014-07-01

    There is an ongoing debate regarding the optimal instrument for scalp incisions: the scalpel or electrocautery. The argument generally focuses on improved healing after an incision made with a knife and decreased bleeding when using electrocautery. This study compares the use of scalpel and electrocautery in making coronal incisions for patients undergoing surgical correction of craniosynostosis. The outcome metric used is wound healing within 6 months after surgery. All patients presenting to the University of North Carolina Children's Hospital with craniosynostosis between July 1, 2007 and January 1, 2010 requiring a coronal incision for surgical correction were prospectively enrolled. In all of these patients, half of the coronal incision was made with knife; the other half, with needle tip cautery. Side of the incision was specified at the time of surgery in the operative report. Patients were excluded from the study if the instrument for incision was not specified or if only 1 modality was used for the entire incision. Sixty-eight patients underwent cranial vault reconstruction, of which 58 met inclusion criteria. Of the 58 matched pairs, 55 were analyzed statistically. The 3 excluded cases were those who had midline complications. There were 17 wound complications (15%): 8 in the knife group, 6 in the cautery group, and 3 at midline (with indeterminate side for the problem). We found no statistically significant difference in wound healing between incisions made with a knife or with electrocautery.

  2. Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision-dependent systems.

    Science.gov (United States)

    Vasavada, Vaishali; Vasavada, Abhay R; Vasavada, Viraj A; Srivastava, Samaresh; Gajjar, Devarshi U; Mehta, Siddharth

    2013-04-01

    To compare incision integrity and clinical outcomes of 2 microcoaxial phacoemulsification systems. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Prospective randomized clinical trial. Eyes were randomized to have phacoemulsification using a 1.8 mm clear corneal incision (CCI) system (Group 1, Stellaris system) or a 2.2 mm CCI system (Group 2, Intrepid Infiniti system). Incision enlargement at end of surgery was measured. At the conclusion of surgery, trypan blue was applied over the conjunctival surface, anterior chamber aspirate withdrawn, and ingress into anterior chamber measured. Postoperative observations included evaluation of the CCI using anterior segment optical coherence tomography (AS-OCT), change in central corneal thickness (CCT), and anterior segment inflammation at 1 day, 1 week, and 1 month and endothelial cell loss and surgically induced astigmatism (SIA) at 3 months. Incision enlargement (P.05). At the end of surgery, it is not the initial incision size alone but also the distortion of the incision during subsequent stages of surgery that determine the integrity of the CCI. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. A multicentre prospective randomised study of single-incision mini-sling (Ajust®) versus tension-free vaginal tape-obturator (TVT-O™) in the management of female stress urinary incontinence: pain profile and short-term outcomes.

    Science.gov (United States)

    Mostafa, Alyaa; Agur, Wael; Abdel-All, Mohamed; Guerrero, Karen; Lim, Chi; Allam, Mohamed; Yousef, Mohamed; N'Dow, James; Abdel-fattah, Mohamed

    2012-11-01

    To compare the postoperative pain profile, peri-operative details, and short-term patient-reported and objective success rates of single-incision mini-slings (SIMS) versus standard mid-urethral slings (SMUS). In a multicentre prospective randomised trial in six UK centres in the period between October 2009 and October 2010, 137 women were randomised to either adjustable SIMS (Ajust®, C. R. Bard Inc., NJ, USA), performed under local anaesthesia as an opt-out policy (n=69), or SMUS (TVT-O™, Ethicon Inc., Somerville, USA) performed under general anaesthesia (n=68). Randomisation was done through number-allocation software and using telephone randomisation. Postoperative pain profile (primary outcome) was assessed on a ten-point visual analogue scale at fixed time-points. Pre- and post operatively (4-6 months) women completed symptom severity, urgency perception scale (UPS), quality of life and sexual function questionnaires. In addition, women completed a Patient Global Impression of Improvement Questionnaire and underwent a cough stress test at 4-6 months follow up. Sample size calculation was performed and data were analysed using SPSS 18. Descriptive analyses are given and between-group comparisons were performed using chi-square, Fischer exact test and Mann-Whitney test as appropriate. Significance level was set at 5%. Women in the SIMS Ajust® group had a significantly lower postoperative pain profile up to 4 weeks (p=TVT-O™ groups respectively. There was a trend towards higher rates of de novo urgency or worsening of pre-existing urgency in the SIMS Ajust® group (21.7% versus 8.8%) but this did not reach statistical significance (p=0.063). Women in the SIMS Ajust® group had shorter hospital stay (median (IQR) 3.65 (2.49, 4.96)) compared to (4.42 (3.16, 5.56)) the TVT-O™ group 95% CI (-0.026, 1.326), with significantly earlier return to normal activities (p=0.025) and to work (p=0.006). The adjustable single-incision mini-sling (Ajust®) is associated

  4. Mini-open transforaminal lumbar interbody fusion.

    Science.gov (United States)

    Tangviriyapaiboon, Teera

    2008-09-01

    To demonstrate the surgical technique and advantages of the mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation. Clinical and radiographic results were assessed to determine the clinical outcomes in twelve consecutive patients selected for minimally invasive access (mini-open technique) for TLIF in Prasat Neurological Institute. A retrospective analysis was performed on 12 patients (age range, 38-74 yr; mean, 54. 8 yr) who underwent mini-open transforaminal approach for lumbar interbody fusion (TLIF) combined with transpedicular screw fixation between September 2006 and June 2008. The titanium pedicle screws were introduced bilaterally through the 3.5 cm length, skin incisions with Spine Classics MLD- system retractor, autologous bone graft were inserted to perform TLIF in all patients. Eight patients were augmented anterior column support with titanium interbody cage, unilateral cage insertion in four patients and the others were inserted bilaterally interbody cages. Six patients presented with low back pain and associated radiculopathy, and six presented with low back pain only. Transforaminal lumbar interbody fusion was performed at L3-L4 in two patients, L4-L5 in four patients, L5-S1 in five patients, and two levels fusion in one patient. All patients were able to ambulate after spinal fusion. The patients were able to walk within 1.4 days (range 1-2 days). The hospital stay averaged 4.4 days (range 3-7 days). Periodic follow-up took place 1 to 21 months after surgery (mean, 7.4 months). The radiological fusion was archived in all nine patients who were operated on more than two months age. The other three patients who had been follow-up less than two months were probably fusion on the 1-month followed-up radiological examination. The use of mini-open technique for pedicle screw instrumentation with spinal fusion procedure provides excellent clinical results and may be an operation of choice for

  5. Minimally invasive mini open split-muscular percutaneous pedicle screw fixation of the thoracolumbar spine

    Directory of Open Access Journals (Sweden)

    Murat Ulutaş

    2015-03-01

    Full Text Available We prospectively assessed the feasibility and safety of a new percutaneous pedicle screw (PPS fixation technique for instrumentation of the thoracic and lumbar spine in this study. All patients were operated in the prone position under general anesthesia. A 6 to 8 cm midline skin incision was made and wide sub-cutaneous dissection was performed. The paravertebral muscles were first dissected subperiosteally into the midline incision of the fascia for lumbar microdiscectomy with transforaminal lumbar interbody fusion cage implantation. After the secondary paramedian incisions on the fascia, the PPSs were inserted via cleavage of the multifidus muscles directly into the pedicles under fluoroscopy visualization. A total of 35 patients underwent surgery with this new surgical technique. The control group for operative time, blood loss and analgesic usage consisted of 35 randomly selected cases from our department. The control group underwent surgery via conventional pedicle screw instrumentation with paramedian fusion. All patients in the minimal invasive surgery series were ambulatory with minimal pain on the first postoperative day. The operation time and blood loss and the postoperative analgesic consumption were significantly less with this new technique. In conclusion, the minimal invasive mini open split-muscular percutaneous pedicle screw fixation technique is safe and feasible. It can be performed via a short midline skin incision and can also be combined with interbody fusion, causing minimal pain without severe muscle damage.

  6. Single-incision total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Sinha Rakesh

    2011-01-01

    Full Text Available Single-incision laparoscopic surgery is an alternative to conventional multiport laparoscopy. Single-access laparoscopy using a transumbilical port affords maximum cosmetic benefits because the surgical incision is hidden in the umbilicus. The advantages of single-access laparoscopic surgery may include less bleeding, infection, and hernia formation and better cosmetic outcome and less pain. The disadvantages and limitations include longer surgery time, difficulty in learning the technique, and the need for specialized instruments. Ongoing refinement of the surgical technique and instrumentation is likely to expand its role in gynecologic surgery in the future. We perform single-incision total laparoscopic hysterectomy using three ports in the single transumbilical incision.

  7. Postoperative Granulomas at Liposuction Incision Sites.

    Science.gov (United States)

    Weniger, Frederick G; White, Peter F; Barrero Castedo, Carlos E

    2016-02-01

    Since most liposuction incisions heal uneventfully, difficult healing in such incisions must be investigated. In the cases of two gynecomastia liposuction patients in which a water-based lubricating gel was used on the liposuction incisions, the incisions failed to heal. For both patients, workup uncovered palisading granulomas at the lateral inframammary fold incision sites several months after otherwise successful surgeries. These two cases are presented and the previous literature is reviewed, with consideration given to the etiology and prevention of such granulomas. LEVEL OF EVIDENCE 5: Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  8. Single incision pediatric endoscopic surgery: advantages of relatively large incision

    International Nuclear Information System (INIS)

    Yilmaz, E.; Afsarlar, E.; Karaman, I.

    2015-01-01

    To describe Single Incision Pediatric Endoscopic Surgery (SIPES) performed on children with various diagnoses, emphasizing its advantages. Study Design: An observational case series. Place and Duration of Study: Department of Pediatric Surgery, Dr. Sami Ulus Maternity and Child Health Hospital, Ankara, Turkey, from January 2011 to November 2014. Methodology: A review of patient charts was conducted in which SIPES was preferred as the surgical procedure. Patient demographics, operative details, operative time, clinical outcomes, postoperative pain and cosmesis were analyzed. Results: SIPES was performed on 45 patients (21 girls, 24 boys). Thirty-three appendectomies, 5 varicocelectomies, 3 oophorectomies, 2 ovarian and one paratubal cyst excision, and one fallopian tube excision were performed. All except one procedures were performed through our standard 2cm umbilical vertical or smile incision. In 18 cases, abdominal irrigation/aspiration was easily performed through the existing larger incision, as is done with open surgical technique. None of the patients had early postoperative shoulder/back pain since complete disinflation of CO/sub 2/ could be ensured. All of the patients/parents were satisfied with the cosmesis. Conclusion: SIPES has the advantages of limiting the surgical scar to within the umbilicus and providing easy disinflation of CO/sub 2/, allowing intraabdominal cleaning and extraction of large volume tissue samples through a single large umbilical incision. (author)

  9. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  10. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  11. [Application of distal palm perforator mini-flap in repair of scar contracture of digital web-spaces].

    Science.gov (United States)

    Zhou, Xiao; Xu, Yajun; Rui, Yongjun; Shou, Kuishui; Yao, Qun

    2011-02-01

    To discuss the effectiveness of distal palm perforator mini-flap in the treatment of scar contracture of digital web-spaces. Between August 2008 and March 2010, 6 cases of scar contracture of digital web-spaces were treated, including 4 males and 2 females and aging 16-68 years (mean, 45 years). The causes were burn injury, twisting injury, and crush injury in 2 cases, respectively. The disease duration was from 3 months to 3 years. The affected digital web-spaces were from index finger to middle finger in 2 cases, from middle finger to ring finger in 3 cases, and from ring finger to small finger in 1 case. The maximum abduction degree of digital web-spaces was 5-10 degrees. The sizes and the depths of reshape of digital web-spaces disappeared. The defect size ranged from 20 mm x 8 mm to 30 mm x 13 mm after opening digital web-spaces. The size of the distal palm perforator mini-flap ranged from 25 mm x 10 mm to 35 mm x 15 mm. The donor sites were sutured directly. All 6 flaps survived and got primary healing. Incisions at donor sites healed by first intention. All patients were followed up 6-12 months. The reconstructed digital web-spaces had good appearance and soft texture. The range of motion of metacarpophalangeal joint was normal. The sizes and the depths of reshape of digital web-spaces were similar to normal ones. The maximum abduction degree of digital web-spaces was 40-60 degrees. There was no scar contracture of incision of palm. The shape of flaps and function of the fingers were satisfactory after 6-12 months of follow-up. It is an ideal method to treat scar contracture of digital web-spaces with distal palm perforator mini-flap.

  12. Modified incision for maxillectomy: our experience.

    Science.gov (United States)

    Bhavana, Kranti; Tyagi, Isha; Ramani, Mukesh Kumar

    2012-06-01

    Radical maxillectomy has usually been done by the classical Weber Ferguson incision since age old times and still is being used widely due to its advantage of excellent exposure and minimal scarring as the incision follows the natural skin crease. In our modification of radical maxillectomy incision we avoid a scar on the midface by performing a midface degloving and combining it with a subconjunctival eye incision thus avoiding any cosmetic deformity and associated eye complication. It also avoids the late complication of cutaneous fistula following radiotherapy to these areas and due to early healing of the wound, early radiotherapy can be started.

  13. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  14. Influence of Incision Location on Transmitter Loss, Healing, Incision Lengths, Suture Retention, and Growth of Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Panther, Jennifer L.; Brown, Richard S.; Gaulke, Greggory L.; Woodley, Christa M.; Deters, Katherine A.

    2010-05-11

    In this study, conducted by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, we measured differences in survival and growth, incision openness, transmitter loss, wound healing, and erythema among abdominal incisions on the linea alba, lateral and parallel to the linea alba (muscle-cutting), and following the underlying muscle fibers (muscle-sparing). A total of 936 juvenile Chinook salmon were implanted with both Juvenile Salmon Acoustic Tracking System transmitters (0.43 g dry) and passive integrated transponder tags. Fish were held at 12°C (n = 468) or 20°C (n = 468) and examined once weekly over 98 days. We found survival and growth did not differ among incision groups or between temperature treatment groups. Incisions on the linea alba had less openness than muscle-cutting and muscle-sparing incisions during the first 14 days when fish were held at 12°C or 20°C. Transmitter loss was not different among incision locations by day 28 when fish were held at 12°C or 20°C. However, incisions on the linea alba had greater transmitter loss than muscle-cutting and muscle-sparing incisions by day 98 at 12°C. Results for wound closure and erythema differed among temperature groups. Results from our study will be used to improve fish-tagging procedures for future studies using acoustic or radio transmitters.

  15. Current Status of Single-incision Laparoscopic Surgery

    DEFF Research Database (Denmark)

    Ahmed, Irfan; Ciancio, Fabio; Ferrara, Vincenzo

    2012-01-01

    Recent advances in minimally invasive surgery have centered on reducing the number of incisions required, which has led to the development of the single-incision laparoscopic technique. A panel of European single-incision laparoscopy experts met to discuss the current status of, and the future...

  16. Electrocautery skin incision for neurosurgery procedures--technical note.

    Science.gov (United States)

    Nitta, Naoki; Fukami, Tadateru; Nozaki, Kazuhiko

    2011-01-01

    The reluctance to incise skin with electrocautery is partly attributable to concerns about excessive scarring and poor wound healing. However, recently no difference was reported in wound complications between the cold scalpel and electrocautery scalpel. We assessed the safety and efficacy of electrocautery skin incision in 22 scalp incisions, including 4 cases of reoperation. Electrocautery skin incisions were created using a sharp needle electrode. The generator unit was set on cutting mode, with power of 6 W and 330 kHz sinusoid waveform. Subcutaneous dissections also used the sharp needle electrode, set on coagulating mode, with power of 10 W and 1 MHz pulse-modulated waveform. Galea incisions used a standard blade tip, set on coagulating mode, with power of 20 W and 1 MHz pulse-modulated waveform. Skin incision with the sharp needle electrode caused no charring of the wound. Little bleeding or oozing were observed and skin clips were not necessary. No wound complication such as necrosis or infection occurred. Electrocautery skin incisions for re-operations were also performed safely without complications. Electrocautery skin incision is sufficiently safe procedure not only for first operation but also for re-operation. Electrocautery skin incision is efficacious, especially for extended operation times, because of little blood loss from the edges of skin incision and possible avoidance of skin edge necrosis or alopecia caused by skin clips.

  17. Comparison of the Keratometric Corneal Astigmatic Power after Phacoemulsification: Clear Temporal Corneal Incision versus Superior Scleral Tunnel Incision

    Directory of Open Access Journals (Sweden)

    Yongqi He

    2009-01-01

    Full Text Available Objective. This is prospective randomized control trial to compare the mean keratometric corneal astigmatism diopter power (not surgical induced astigmatism among preop and one-month and three-month postop phacoemulcification of either a clear temporal corneal incision or a superior scleral tunnel Incision, using only keratometric astigmatic power reading to evaluate the difference between the two cataract surgery incisions. Methods. 120 patients (134 eyes underwent phacoemulcification were randomly assigned to two groups: Group A, the clear temporal corneal incision group, and Group B, the superior scleral tunnel incision group. SPSS11.5 Software was used for statistical analysis to compare the postsurgical changes of cornea astigmatism on keratometry. Results. The changes of corneal astigmatic diopter in Groups A and B after 3 month postop from keratometric reading were 1.04 + 0.76 and 0.94 + 0.27, respectively (=.84>.05, which showed no statistic significance difference. Conclusion. The incision through either temporal clear cornea or superior scleral tunnel in phacoemulcification shows no statistic difference in astigmatism change on keratometry 3-month postop.

  18. Single scrotal incision orchiopexy - a systematic review

    Directory of Open Access Journals (Sweden)

    Hugo Fabiano Fernandes Novaes

    2013-06-01

    Full Text Available Objective To conduct a systematic review on single scrotal incision orchiopexy. Materials and Methods A search was performed using Pubmed, through which 16 articles were selected out of a total of 133. The following conditions were considered exclusion criteria: other surgical methods such as an inguinal procedure or a laparoscopic approach, retractile testes, or patients with previous testicular or inguinal surgery. Results A total of 1558 orchiopexy surgeries initiated with a transcrotal incision were analyzed. Patients' ages ranged between 5 months and 21 years. Thirteen studies used high scrotal incisions, and low scrotal incisions were performed in the remainder of the studies. In 55 cases (3.53%, there was a need for inguinal incision. Recurrence was observed in 9 cases, testicular atrophy in 3, testicular hypotrophy in 2, and surgical site infections in 13 cases. High efficacy rates were observed, varying between 88% and 100%. Conclusions Single scrotal incision orchiopexy proved to be an effective technique and is associated with low rates of complications.

  19. Flexible single-incision surgery: a fusion technique.

    Science.gov (United States)

    Noguera, José F; Dolz, Carlos; Cuadrado, Angel; Olea, José; García, Juan

    2013-06-01

    The development of natural orifice transluminal endoscopic surgery has led to other techniques, such as single-incision surgery. The use of the flexible endoscope for single-incision surgery paves the way for further refinement of both surgical methods. To describe a new, single-incision surgical technique, namely, flexible single-incision surgery. Assessment of the safety and effectiveness of endoscopic cholecystectomy in a series of 30 patients. This technique consists of a single umbilical incision through which a flexible endoscope is introduced and consists of 2 parallel entry ports that provide access to nonarticulated laparoscopic instruments. The technique was applied in all patients for whom it was prescribed. No general or surgical wound complications were noted. Surgical time was no longer than usual for single-port surgery. Flexible single-incision surgery is a new single-site surgical technique offering the same level of patient safety, with additional advantages for the surgeon at minimal cost.

  20. Vertical compared with transverse incisions in abdominal surgery

    DEFF Research Database (Denmark)

    Grantcharov, T P; Rosenberg, J

    2001-01-01

    , and late complications (incisional hernia). RESULTS: Eleven randomised controlled trials and seven retrospective studies were identified. The transverse incision offers as good an access to most intra-abdominal structures as a vertical incision. The transverse incision results in significantly less......OBJECTIVE: To reach an evidence-based consensus on the relative merits of vertical and transverse laparotomy incisions. DESIGN: Review of all published randomised controlled trials that compared the postoperative complications after the two main types of abdominal incisions, vertical and transverse....... SETTING: Teaching hospital, Denmark. SUBJECTS: Patients undergoing open abdominal operations. INTERVENTIONS: For some of the variables (burst abdomen and incisional hernia) it was considered adequate to include retrospective studies. Studies were identified through Medline, Cochrane library, Embase...

  1. Two-Step Incision for Periarterial Sympathectomy of the Hand

    Directory of Open Access Journals (Sweden)

    Seung Bae Jeon

    2015-11-01

    Full Text Available BackgroundSurgical scars on the palmar surface of the hand may lead to functional and also aesthetic and psychological consequences. The objective of this study was to introduce a new incision technique for periarterial sympathectomy of the hand and to compare the results of the new two-step incision technique with those of a Koman incision by using an objective questionnaire.MethodsA total of 40 patients (17 men and 23 women with intractable Raynaud's disease or syndrome underwent surgery in our hospital, conducted by a single surgeon, between January 2008 and January 2013. Patients who had undergone extended sympathectomy or vessel graft were excluded. Clinical evaluation of postoperative scars was performed in both groups one year after surgery using the patient and observer scar assessment scale (POSAS and the Wake Forest University rating scale.ResultsThe total patient score was 8.59 (range, 6-15 in the two-step incision group and 9.62 (range, 7-18 in the Koman incision group. A significant difference was found between the groups in the total PS score (P-value=0.034 but not in the total observer score. Our analysis found no significant difference in preoperative and postoperative Wake Forest University rating scale scores between the two-step and Koman incision groups. The time required for recovery prior to returning to work after surgery was shorter in the two-step incision group, with a mean of 29.48 days in the two-step incision group and 34.15 days in the Koman incision group (P=0.03.ConclusionsCompared to the Koman incision, the new two-step incision technique provides better aesthetic results, similar symptom improvement, and a reduction in the recovery time required before returning to work. Furthermore, this incision allows the surgeon to access a wide surgical field and a sufficient exposure of anatomical structures.

  2. Liquid in the major incision

    International Nuclear Information System (INIS)

    Herrera Jaramillo, Diego Alberto; Ortega Jaramillo, Hector

    2003-01-01

    We present the case of a patient with spill pleural extending in the left major incision. In the chest thorax PA, we could observe one of the complex radiographic appearances that take the reconfiguration of fluid in this localization, being this appearance dependent of the patient's position. Some points are also discussed on the anatomy of the major incisions and some of their radiographic characteristics

  3. Effects of post-treatment incubation on recombinogenesis in incision-proficient and incision-deficient strains of saccharomyces cerevisiae, 2

    International Nuclear Information System (INIS)

    Saeki, Tetsuya; Machida, Isamu

    1991-01-01

    After the photoaddition of mono- and bifunctional furocoumarins to G1 phase cells, most gene conversion and crossing-over occurred without post-irradiation incubation of these cells in incision-proficient strains. In contrast, incision-deficient cells showed marked induction of both recombinational events only after treated cells had been incubated for several hours before selection. These results indicate that when furocoumarins are photoadded to G1 cells, initiation of recombinational events occurs during the same G1 phase in the incision-proficient cells; whereas, it occurs only after post-irradiation DNA replication in incision-deficient cells. The action of the PSO2 gene product specific for the repair of DNA crosslinks in recombination induction is discussed and compared to the actions of the excision repair genes RAD1 and RAD2. (author)

  4. DNA Methylation Modulates Nociceptive Sensitization after Incision.

    Directory of Open Access Journals (Sweden)

    Yuan Sun

    Full Text Available DNA methylation is a key epigenetic mechanism controlling DNA accessibility and gene expression. Blockade of DNA methylation can significantly affect pain behaviors implicated in neuropathic and inflammatory pain. However, the role of DNA methylation with regard to postoperative pain has not yet been explored. In this study we sought to investigate the role of DNA methylation in modulating incisional pain and identify possible targets under DNA methylation and contributing to incisional pain. DNA methyltranferase (DNMT inhibitor 5-Aza-2'-deoxycytidine significantly reduced incision-induced mechanical allodynia and thermal sensitivity. Aza-2'-deoxycytidine also reduced hindpaw swelling after incision, suggesting an anti-inflammatory effect. Global DNA methylation and DNMT3b expression were increased in skin after incision, but none of DNMT1, DNMT3a or DNMT3b was altered in spinal cord or DRG. The expression of proopiomelanocortin Pomc encoding β-endorphin and Oprm1 encoding the mu-opioid receptor were upregulated peripherally after incision; moreover, Oprm1 expression was further increased under DNMT inhibitor treatment. Finally, local peripheral injection of the opioid receptor antagonist naloxone significantly exacerbated incision-induced mechanical hypersensitivity. These results suggest that DNA methylation is functionally relevant to incisional nociceptive sensitization, and that mu-opioid receptor signaling might be one methylation regulated pathway controlling sensitization after incision.

  5. Comparison of single-incision mini-slings (Ajust) and standard transobturator midurethral slings (Align) in the management of female stress urinary incontinence: A 1-year follow-up.

    Science.gov (United States)

    Chang, Chia-Pei; Chang, Wen-Hsun; Hsu, Yen-Mei; Chen, Yi-Jen; Wen, Kuo-Chang; Chao, Kuan-Chong; Yen, Ming-Shyen; Horng, Huann-Cheng; Wang, Peng-Hui

    2015-12-01

    To investigate the effectiveness and safety of a new single-incision mini-sling (SIMS)-Ajust-compared with the standard transobturator midurethral sling (SMUS)-Align-for the treatment of female stress urinary incontinence (SUI). A retrospective cohort study was conducted between January 1, 2010 and August 31, 2012. Women with SUI who underwent either SMUS-Align or SIMS-Ajust were recruited. The primary outcomes included operation time, estimated operative blood loss, postoperative pain, and complications. The secondary outcomes included subjective and objective success, defined as an International Consultation on Incontinence Questionnaire (ICIQ) score of 0 or improvement as felt by the patient and a long-term complication, such as dyspareunia and mesh erosion after 6 months and 12 months of follow-up. A total of 136 patients were enrolled, including 76 receiving SMUS-Align and 60 receiving SIMS-Ajust. Baseline characteristics of the patients in both groups were similar, without a statistically significant difference. Primary outcomes between both groups were similar, except that women treated with SIMS-Ajust had statistically significantly shorter operation time (p = 0.003), less intent to treat (p < 0.05), and earlier postoperative discharge (p = 0.001) than women treated with SMUS-Align. Secondary outcomes were similar without a significant difference between the two groups (93% vs. 88% success rate in each group). Our results showed that SIMS-Ajust was not inferior to SMUS-Align with respect to success rate, and might have a slight advantage in early discharge. A long-term follow-up or prospective study is needed to confirm the above findings. Copyright © 2015. Published by Elsevier B.V.

  6. Morphodynamic Model of Submarine Canyon Incision by Sandblasting

    Science.gov (United States)

    Zhang, L.; Parker, G.; Izumi, N.; Cartigny, M.; Li, T.; Wang, G.

    2017-12-01

    Submarine canyons are carved by turbidity currents under the deep sea. As opposed to subaerial canyons, the relevant processes are not easy to observe directly. Turbidity currents are bottom-hugging sediment gravity flows of that can incise or deposit on the seafloor to create submarine canyons or fans. The triggers of turbidity currents can be storms, edge waves, internal waves, canyon wall sapping, delta failure, breaching and hyperpycnal flows. The formation and evolution mechanisms of submarine canyons are similar to those of subaerial canyons, but have substantial differences. For example, sandblasting, rather than wear due to colliding gravel clasts is more likely to be the mechanism of bedrock incision. Submarine canyons incise downward, and often develop meander bends and levees within the canyon, so defining "fairways". Here we propose a simple model for canyon incision. The starting point of our model is the Macro Roughness Saltation Abrasion Alluviation model of Zhang et al. [2015], designed for bedrock incision by gravel clasts in mixed bedrock-alluvial rivers. We adapt this formulation to consider sandblasting as a means of wear. We use a layer-averaged model for turbidity current dynamics. The current contains a mixture of mud, which helps drive the flow but which does not cause incision, and sand, which is the agent of incision. We show that the model can successfully model channel downcutting, and indeed illustrate the early formation of net incisional cyclic steps, i.e. upstream-migrating undulations on the bed associated with transcritical (in the Froude sense) flow. These steps can be expected to abet the process of incision.

  7. Comparative study between endoscopic technique by a proximal port and mini palmary incision in the surgical treatment of carpal tunnel syndrome Estudo comparativo entre a técnica endoscópica pelo portal proximal e a técnica de mini-incisão palmar no tratamento cirúrgico da síndrome do túnel do carpo

    Directory of Open Access Journals (Sweden)

    Eduardo A.R. Pereira

    2003-01-01

    Full Text Available The authors present a prospective study comparing two surgical techniques for carpal tunnel release. A minimal - incision open decompression(3 is compared with an endoscopic release(2, that utilizes only a single proximal portal. There were operated on, 28 wrists in 28 patients, with clinical signs and EMG changes consistent on idiopathic carpal tunnel syndrome, that failed under previous conservative treatment. They were randomized into two groups , undertaken surgical treatment, either by endoscopic release or by open decompression. Grip strength (measured by dynamometric, sensitivity (measured by Semmes-Weinstein monofilaments, presence of pain and paresthesia, date of return to activities of daily living and complications were evaluated pre-operative and at 1, 2, 4, 6, 12 weeks after surgery. After 12 months average follow up, the results indicated that this proximal portal endoscopic technique can be safely performed, showing advantages over open conventional method, in terms of sooner return of grip strength, date of return to activities of daily living, and less incidence of pillar pain. No differences in paresthesia resolution, sensibility improvement or complications incidence were found.Os autores apresentam estudo prospectivo onde comparam duas técnicas cirúrgicas empregadas no tratamento de pacientes acometidos pela síndrome do túnel do carpo. A técnica de descompressão por via aberta, através de mini-incisão palmar(3, é analisada em relação à técnica por via endoscópica, descrita por Agee et al.(2, que utiliza apenas um único portal proximal. Foram operados, de forma randomizada, 28 punhos em 28 pacientes com o diagnóstico clínico e eletromiográfico de síndrome do túnel do carpo idiopático, e que não obtiveram melhora com o tratamento conservador prévio. Os seguintes parâmetros, foram analisados no pré-operatório e na primeira, segunda, quarta, sexta e décima segunda semanas de pós-operatório: força de

  8. Incidence of vascular complications during lateral lumbar interbody fusion: an examination of the mini-open access technique.

    Science.gov (United States)

    Kueper, Janina; Fantini, Gary A; Walker, Brendon R; Aichmair, Alexander; Hughes, Alexander P

    2015-04-01

    This article examines the incidence and management of vascular injury during Lateral Lumbar Interbody Fusion (LLIF). The details of the mini-open access technique are presented. A total of 900 patients who underwent a LLIF at an average 1.94 levels (range: 1-5 levels) by one of six fellowship trained surgeons on 1,754 levels from 2006 to 2013 were identified. The incidence of intraoperative vascular injury was retrospectively determined from the Operative Records. The management of vascular injury was evaluated. The mini-open access adapted by our institution for LLIF is described. The incidence of major vascular complication in our series was 1/900. The incidence of minor vascular injury was 4/900. The overall incidence of vascular injury was calculated to be 0.056 % per case and 0.029 % per level. All minor vascular injuries were identified to be segmental vessel lacerations, which were readily ligated under direct visualization without further extension of the incision with no clinical sequelae. The laceration of the abdominal aorta, the major vascular complication of this series, was emergently repaired through an exploratory laparotomy. None of the patients suffered long-term sequelae from their intraoperative vascular injuries. The mini-open lateral access technique for LLIF provides for minimal risk of vascular injury to the lumbar spine. In the rare event of minor vascular injury, the mini-open access approach allows for immediate visualization, confirmation and repair of the vessel with no long-term sequelae.

  9. Transjejunal Extraction of Gallbladder After Mini-Laparoscopic Cholecystectomy in Patients with Previous Roux-en-Y Gastric Bypass: A Small Case Series.

    Science.gov (United States)

    Kayaalp, Cuneyt; Tardu, Ali; Yagci, Mehmet Ali; Sumer, Fatih

    2015-07-01

    The length of incisions on the abdominal wall directly correlates with wound-related morbidities and patient comfort. Both mini-laparoscopy (only ≤5-mm trocars) and natural orifice specimen extraction avoid larger abdominal incisions. This study described a new natural orifice translumenal endoscopic surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and Society of American Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) cholecystectomy technique by combination of these two advanced laparoscopic techniques for cholelithiasis in patients who had prior laparoscopic Roux-en-Y gastric bypass (LRYGB) for obesity. Three patients (two males, one female; 39, 62, and 34 years old, respectively) were admitted with symptomatic cholelithiasis (multiple millimeter-sized gallstones), and all had previously had LRYGB. They were treated by mini-laparoscopic cholecystectomy using three 5-mm trocars. The gallbladder was removed through the dilated efferent limb of the jejunum, 5 cm distal from the gastrojejunostomy. Transjejunal extraction was performed under endoscopic guidance. The gallbladder in the jejenum was passed through the anastomosis and extracted with an endoscopic snare by the transoral way. The enterotomy was closed intracorporeally. There was no conversion or additional trocar requirement. All the procedures were completed successfully without problems. Respective operating times were 95, 75, and 120 minutes. Only 1 patient required postoperative analgesic; the others did not. The patients started to get a liquid diet on the night of surgery and were discharged on Days 1, 1, and 2, respectively, with normal diet recommendations. There were no morbidities. Mini-laparoscopic cholecystectomy is technically feasible in patients with previous LRYGB. Prior LRYGB was not an obstacle for transoral specimen extraction. The dilated efferent jejunal limb is a good alternative route for natural orifice specimen extraction. This

  10. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, Claus Thorn

    2016-01-01

    incision between January 1995 and June 2012 were reviewed. Horses with a laryngotomy incision closed in three layers for primary healing were included. Descriptive data on healing characteristics and complications of laryngotomy wounds were collected from the medical records and via follow......The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy...... after primary closure of equine laryngotomy incisions are infrequent and considered of minimal severity and can be performed safely when paying careful attention to the closure of the cricothyroid membrane....

  11. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  12. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  13. Revisiting the functional anatomy of the palmaris longus as a thenar synergist.

    Science.gov (United States)

    Moore, Colin W; Fanous, Jacob; Rice, Charles L

    2017-11-27

    Surgical studies describe the palmaris longus (PL) as a synergist in thumb abduction, which may facilitate its use in restoring thumb function using opponensplasty. However, beyond morphological descriptions and isometric thenar abduction strength measures, the evidence supporting the PL as a thenar synergist in-vivo is limited. The purpose here was to determine whether the PL provides synergistic contributions to thenar musculature by: (1) recording PL muscle activity using indwelling electromyography (EMG) during thumb movements; and (2) quantifying changes in PL muscle architecture using ultrasonography. In 10 healthy males, PL muscle activity was recorded during maximal thenar muscle contractions (abduction, flexion, opposition, adduction, and extension) with the wrist secured in a neutral position. The PL EMG was normalized to its maximal EMG recorded during isometric wrist flexion. Dynamic changes in PL muscle thickness (M T ) were determined during abduction and adduction using ultrasound imaging. The results indicate that the PL is activated during thenar movements with greatest relative PL EMG recorded during thenar abduction (46%), flexion (35%) and opposition (37%). Compared to rest, PL M T significantly increased (21%) during maximal thenar abduction. With direct measures in vivo, this study supports morphological and surgical observations indicating the PL acts as an extrinsic hand muscle in enhancing thenar muscle actions. Knowledge of the synergistic relationship between the PL and thenar musculature may allow for further development of surgical opponensplasty approaches using the abductor pollicis brevis and PL as a functional digastric unit. Clin. Anat, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Evaluation of apical root resorption in orthodontic patients with maxillary anterior intrusion using utility arches and mini screws: A comparative clinical trial

    Directory of Open Access Journals (Sweden)

    Muraleedhara Bhat

    2014-01-01

    Full Text Available Objectives: The purpose of this study was to compare the amount of apical root resorption in orthodontic patients undergoing maxillary anterior intrusion using utility arches and mini screws; and to compare the efficacy of mini screws and utility arches in reducing over bite. Materials and Methods: The study sample consisted of 20 patients, divided in two groups. Group A consisted of ten patients in whom titanium mini-screws were used Group B consisted of 10 patients in whom utility arches made of 0.017 × 0.25" TMA were used. Diagnostic records (study models and radiovisiography [RVG] were taken at 2 time intervals, T1 (just before implant/utility arch placement and T2 (at the end of intrusion 6 months later. The pre and post radiographic images were measured from incisal tip to the root apex with the help of intrascan DC software. Root resorption was computed as the difference between the pre-treatment total tooth length and the post treatment total tooth length. These values were subjected to statistical analyses using SPSS 16.00 statistical software. (Statistical Package for the Social Sciences, IBM Corporation, December 2007 Results: The results showed that root resorption was seen in both groups. Amount of resorption seen was higher in mini implant group than utility arch group. Mini implants were more efficient in reducing the overbite when compared to utility arches. Conclusion: It was concluded from the study that intrusion using mini implant resulted in more root resorption than utility arch; and mini implant was more effective in intruding the incisors than utility arch.

  15. Single Incision Laparoscopic Splenectomy: Our First Experiences

    Directory of Open Access Journals (Sweden)

    Umut Barbaros

    2011-06-01

    Full Text Available Objective: Most laparoscopic surgeons have attempted to reduce incisional morbidity and improve cosmetic outcomes by using less and smaller trocars. Single incision laparoscopic splenectomy is a new laparoscopic procedure. Herein we would like to present our experiences.Material and Methods: Between January 2009 and June 2009, data of the 7 patients who underwent single incision laparoscopic splenectomy were evaluated retrospectively.Results: There were 7 patients (5 females and 2 males with a mean age of 29.9 years. The most common splenectomy indication was idiopathic thrombocytopenic purpura. Single incision laparoscopic splenectomy was performed successfully in 6 patients. In one patient the operation was converted to an open procedure.Conclusion: With surgeons experienced in minimally invasive surgery, single incision laparoscopic splenectomy could be performed successfully. However, in order to demonstrate the differneces between standard laparoscopic splenectomy and SILS splenetomy, prospective randomized comparative studies are required.

  16. Intraoperative Ultrasound-Guided Removal of Retained Mini Sling Anchor Causing Vaginal Pain: A Case Report.

    Science.gov (United States)

    Almassi, Nima; Goldman, Howard B

    2016-01-01

    Since the introduction of the tension-free vaginal tape, the surgical management of female stress urinary incontinence has undergone a dramatic shift toward synthetic midurethral slings (MUSs). The evolution of the MUS has led to the development of the single incision mini sling (SIMS), a minimally invasive procedure that can be performed under local anesthesia. Complications arising after SIMS placement parallel those of the traditional MUS, including pelvic pain, dyspareunia, and mesh erosion. The patient in this case presented with persistent pelvic pain due to a retained SIMS anchor after having previously undergone SIMS placement and subsequent transvaginal exploration with mesh removal. We report the use of intraoperative ultrasound for identification and removal of the retained SIMS anchor.

  17. Incisive canal deflation for correct implant placement: case report.

    Science.gov (United States)

    Spin-Neto, Rubens; Bedran, Telma Blanca Lombardo; de Paula, Wagner Nunes; de Freitas, Rubens Moreno; de Oliveira Ramalho, Lizeti Toledo; Marcantonio, Elcio

    2009-12-01

    This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of an implant that is to be osseointegrated. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve, which are responsible for the anterior upper-tooth pulp, the periodontium vascularization and the innervation. From the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation. Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient.

  18. Incidence of agenesis of palmaris longus in the Andhra population of India

    Directory of Open Access Journals (Sweden)

    K Devi Sankar

    2011-01-01

    Full Text Available Background : The knowledge of Palmaris longus (PL is a growing interest for its wide role in reconstructive plastic surgeries as a donor tendon for transfer or transplant. The prevalence of the PL agenesis has been well-documented by many authors in different ethnic groups or populations. Many conventional tests for determining the presence of the PL has been described, but lamentably there are many discrepancies in confirming its presence or absence. Slight modifications of the prevailing methods can still give authenticate results. Aim : This prospective study was conducted to determine the incidence of unilateral and bilateral agenesis of PL and its association with sex and side of the limb in the Andhra population of India. Materials and Methods : A total of 942 subjects of both sexes belonging to 18-23 years were used to access the PL using various tendon examination techniques including our modified Schaeffer′s test. The data collected were analyzed by Pearsons χ2 test using SPSS software. Results : Overall agenesis of muscle in both sexes was 264 (28.0%, out of which 40.2% was seen in females and 14.7% in males with the ratio of 3:1. The unilateral agenesis was seen in 70.5% and bilateral agenesis in 29.5% subjects. The left side agenesis was seen in 51.6% and right side in 48.4% subjects. Conclusions : The prevalence of bilateral and unilateral agenesis was more common on left side with a greater likelihood in the female subjects. The proposed technique could bring better results in all subjects and can be implemented in manual examination of PL.

  19. Two new mini-slings compared with transobturator tension-free vaginal tape for treatment of stress urinary incontinence: A 1-year follow-up randomized controlled trial.

    Science.gov (United States)

    Gaber, Mohamed E; Borg, Tamer; Samour, Hazem; Nawara, Mai; Reda, Ahmed

    2016-12-01

    The aim of this study was to compare the outcome of two single-incision mini-slings (the Contasure-Needleless [C-NDL] and the endopelvic free anchorage) with the standard midurethral transobturator tension-free vaginal tape (TVT-O) procedure. A double blind randomized controlled study was conducted at Ain Shams University Maternity Hospital from August 2014 until July 2015. A total of 209 patients were randomized into three groups. The first group underwent the TVT-O procedure, the second group underwent the endopelvic free anchorage procedure and the third group underwent the C-NDL procedure. Patients were followed up for 12 months in terms of subjective cure, objective cure, and complications rate. After 12 months of follow-up, there were no differences among the three groups in terms of objective cure rate, subjective cure rate, patient satisfaction, or incidence of complications (de novo urge, hemorrhage, infection, and mesh erosion). The C-NDL was associated with a shorter operative time (P < 0.001) and less blood loss (P = 0.021) than the standard TVT-O. The new single-incision mini-slings showed similar efficacy and patient acceptance to that of the standard TVT-O for up to 12 months postoperatively with no difference in the complications rate. The C-NDL is associated with shorter operative time and less blood loss. © 2016 Japan Society of Obstetrics and Gynecology.

  20. Higher Incision at Upper Part of Lower Segment Caesarean Section

    Directory of Open Access Journals (Sweden)

    Yong Shao

    2014-06-01

    Conclusions: An incision at the upper part of the lower segment reduces blood loss, enhances uterine retraction, predisposes to fewer complications, is easier to repair, precludes bladder adhesion to the suture line and reduces operation time. Keywords: caesarean section; higher incision technique; traditional uterine incision technique.

  1. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  2. Effects of two different incision phacoemulsification on corneal astigmatism

    Directory of Open Access Journals (Sweden)

    Lu Huo

    2014-12-01

    Full Text Available AIM:To compare the effect of different incision in corneal astigmatism after phacoemulsification. METHODS: Totally 88 cases(122 eyeswith pure cataract were randomly divided into two groups. Forty cases(60 eyeswere clarity corneal incision in group A, and 48 cases(62 eyeswere sclera tunnel incision in group B. Mean corneal astigmatism, surgically induced astigmatism(SIA, uncorrected visual acuity(UCVAand best correct vision acuity(BCVAwere observed in pre- and post-operation at 1d; 1wk; 1mo.RESULTS: The mean astigmatism had statistically significant difference between two groups at 1d; 1wk; 1mo after operation(PPP>0.05. UCVA≥0.5 and BCVA≥0.8 had statistically significant difference at 1d; 1wk(PP>0.05.CONCLUSION: Phacoemulsification with scleral tunnel incision remove combined intraocular lens(IOLimplantation has small changes to corneal astigmatism. By selecting personalized corneal incision according to the corneal topography might be more beneficial.

  3. Single incision laparoscopic colorectal resection: Our experience

    Directory of Open Access Journals (Sweden)

    Chinnusamy Palanivelu

    2012-01-01

    Full Text Available Background: A prospective case series of single incision multiport laparoscopic colorectal resections for malignancy using conventional laparoscopic trocars and instruments is described. Materials and Methods: Eleven patients (seven men and four women with colonic or rectal pathology underwent single incision multiport laparoscopic colectomy/rectal resection from July till December 2010. Four trocars were placed in a single transumblical incision. The bowel was mobilized laparoscopically and vessels controlled intracorporeally with either intra or extracorporeal anastomosis. Results: Three patients had carcinoma in the caecum, one in the hepatic flexure, two in the rectosigmoid, one in the descending colon, two in the rectum and two had ulcerative pancolitis (one with high grade dysplasia and another with carcinoma rectum. There was no conversion to standard multiport laparoscopy or open surgery. The median age was 52 years (range 24-78 years. The average operating time was 130 min (range 90-210 min. The average incision length was 3.2 cm (2.5-4.0 cm. There were no postoperative complications. The average length of stay was 4.5 days (range 3-8 days. Histopathology showed adequate proximal and distal resection margins with an average lymph node yield of 25 nodes (range 16-30 nodes. Conclusion: Single incision multiport laparoscopic colorectal surgery for malignancy is feasible without extra cost or specialized ports/instrumentation. It does not compromise the oncological radicality of resection. Short-term results are encouraging. Long-term results are awaited.

  4. Diathermy versus scalpel incisions for open cholecystectomy comparative study

    International Nuclear Information System (INIS)

    Ali, M.A.; Niazi, W.A.K.

    2014-01-01

    The aim of the study was to make a comparison between skin incisions made with electrocautery versus scalpel in terms of their safety, efficacy and post-operative complications. Design: A randomized controlled study. Setting: The study was conducted in Combined Military Hospital (CMH) Kharian, Pakistan airforce (PAF) Hospital Sargodha. Duration of Study: May 2008 to August 2011. Patients and Methods: Ninety seven patients who underwent open cholecystectomy were randomly divided into two groups on the basis of the use of electrocautery versus steel scalpel for making skin incision and sub-cutaneous tissue dissection. Parameters recorded were, time taken from skin incision to full incising of the peritoneum, length of the wound, amount of blood loss during this step of surgery in each group. Post-operative pain scoring using visual analogue scale was done. Wound complications such as infection, haematoma/seroma and dehiscence were noted too. One month of follow up was recorded in each group. Subsequently a comparison of these findings was done. Results: Incision time (sec/cm/sub 2/) was longer in scalpel group than in diathermy group (p = 0.001), whereas, incision blood loss (ml/cm/sub 2/) was significantly less in diathermy group than in scalpel group (p = 0.03). There was no difference in post-operative pain perception as delineated by visual pain analogue scoring system between the two groups (p = 0.57). Post-operative wound complications and the final healing of wound at 01 month of follow-up were almost similar in both groups. Conclusion: Electrocautery may be used safely without any untoward complication in making skin incision and sub-cutaneous tissue dissection with an advantage of reduced incision time and and less blood loss. (author)

  5. Exploratory study assessing efficacy and complications of TVT-O, TVT-Secur, and Mini-Arc: results at 12-month follow-up.

    Science.gov (United States)

    Oliveira, Rui; Botelho, Francisco; Silva, Pedro; Resende, Alexandre; Silva, Carlos; Dinis, Paulo; Cruz, Francisco

    2011-06-01

    Contemporary surgical treatment of female stress urinary incontinence (SUI) includes retropubic and transobturator (TO) midurethral slings (MUS). Case series of single-incision slings (SIS) have shown similar outcomes with lower morbidity. Our aim was to assess the cure rates, complications, and quality-of-life impact of one standard TO MUS and two SIS. Ninety consecutive patients with clinically and urodynamically proven SUI were enrolled in an exploratory randomised phase 2 trial. Patients with previous SUI surgery, major pelvic organ prolapse, mixed incontinence, or detrusor overactivity were excluded. Patients were treated randomly with TVT-O, TVT-Secur, or Mini-Arc. Postoperative visits were scheduled at 6 and 12 mo. The King's Health Questionnaire (KHQ) was repeated at 6 mo. Cure was defined as the absence of urine leakage, no pad use, and a negative cough test at 12 mo. Pain and other complications were also investigated. Cure rate was 83% after TVT-O, 67% after TVT-Secur, and 87% after Mini-Arc. Improvement was found in 10%, 13%, and 7% of the patients, respectively. Failures were 7% after TVT-O and Mini-Arc and 20% after TVT-Secur. TVT-O and Mini-Arc improved at least 15 points in >80% of the patients in six KHQ domains, whereas TVT-Secur could only achieve improvement in three of the nine domains. The pain score was lower in the Mini-Arc group. Complications were more numerous after TVT-O. This study has the limitations inherent in a phase 2 trial with a follow-up limited to 12 mo. Mini-Arc offers cure and improvement rates similar to TVT-O, whereas TVT-Secur may yield an inferior outcome. These findings recommend the urgent launch of large randomised phase 3 studies comparing conventional MUS with SIS, with Mini-Arc the advised option. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  7. Single-incision laparoscopic surgery for pyloric stenosis.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Podkamenev, Alexey; Rasputin, Andrey; Weber, Irina; Solovjev, Alexey; Yurkov, Pavel

    2012-04-01

    Laparoscopy is the most common procedure for correction of congenital pyloric stenosis. The standard laparoscopic approach is based on the three-port technique. In contrast to the standard laparoscopic technique, the single-incision laparoscopic surgery (SILS) requires only one incision. We report on our experience with this surgical approach. Between September 2009 and August 2010 a total of 24 children underwent a laparoscopic pyloromyotomy, 12 in SILS technique. The single incision was carried through the center of the umbilicus. The working instruments were introduced in a two-dimensional direction into the peritoneal cavity via the same umbilical incision. The two groups were compared for patients' demographics, operative report and early postoperative outcomes. All SILS procedures were performed successfully with no conversion rate. There were no differences in the preoperative parameters between the two groups regarding age before surgery and body weight at operation. Operative time and time of full enteral intake was similar to comparable procedures with usage of a standard laparoscopic approach. There were no operative or postoperative complications. The early experience described in this study confirms that SILS can be applied for treatment of pyloric stenosis with outcomes similar to the standard laparoscopic surgery.

  8. Transurethral incision of urethral diverticulum in the female

    DEFF Research Database (Denmark)

    Miskowiak, J; Honnens de Lichtenberg, M

    1989-01-01

    A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time.......A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time....

  9. In vitro conjunctival incision repair by temperature-controlled laser soldering.

    Science.gov (United States)

    Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham

    2009-01-01

    The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.

  10. Minimal abdominal incisions

    Directory of Open Access Journals (Sweden)

    João Carlos Magi

    2017-04-01

    Full Text Available Minimally invasive procedures aim to resolve the disease with minimal trauma to the body, resulting in a rapid return to activities and in reductions of infection, complications, costs and pain. Minimally incised laparotomy, sometimes referred to as minilaparotomy, is an example of such minimally invasive procedures. The aim of this study is to demonstrate the feasibility and utility of laparotomy with minimal incision based on the literature and exemplifying with a case. The case in question describes reconstruction of the intestinal transit with the use of this incision. Male, young, HIV-positive patient in a late postoperative of ileotiflectomy, terminal ileostomy and closing of the ascending colon by an acute perforating abdomen, due to ileocolonic tuberculosis. The barium enema showed a proximal stump of the right colon near the ileostomy. The access to the cavity was made through the orifice resulting from the release of the stoma, with a lateral-lateral ileo-colonic anastomosis with a 25 mm circular stapler and manual closure of the ileal stump. These surgeries require their own tactics, such as rigor in the lysis of adhesions, tissue traction, and hemostasis, in addition to requiring surgeon dexterity – but without the need for investments in technology; moreover, the learning curve is reported as being lower than that for videolaparoscopy. Laparotomy with minimal incision should be considered as a valid and viable option in the treatment of surgical conditions. Resumo: Procedimentos minimamente invasivos visam resolver a doença com o mínimo de trauma ao organismo, resultando em retorno rápido às atividades, reduções nas infecções, complicações, custos e na dor. A laparotomia com incisão mínima, algumas vezes referida como minilaparotomia, é um exemplo desses procedimentos minimamente invasivos. O objetivo deste trabalho é demonstrar a viabilidade e utilidade das laparotomias com incisão mínima com base na literatura e

  11. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI).

    Science.gov (United States)

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-05-22

    There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen's kappa and "observed agreement". There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and "observed agreement" was above 88%. The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language.

  12. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    Science.gov (United States)

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnostic interview by clinical experts and with the MINI. Inter-rater reliability was assessed with Cohen’s kappa and “observed agreement”. Results There was 65% agreement between MINI diagnoses and clinical expert diagnoses. Kappa values indicated fair to moderate agreement, and observed agreement was above 76% for all diagnoses. The MINI diagnosed more co-morbid conditions than did the clinical expert interview (mean diagnoses: 1.9 versus 1.2). Kappa values indicated moderate to substantial agreement, and “observed agreement” was above 88%. Conclusion The NSL version performs similarly to other MINI versions and demonstrates adequate reliability and validity as a diagnostic instrument for assessing mental disorders in persons who have sign language as their primary and preferred language. PMID:24886297

  13. Structural and functional anatomy of the palmaris brevis: grasping for answers.

    Science.gov (United States)

    Moore, Colin W; Rice, Charles L

    2017-12-01

    The palmaris brevis (PB) is a small cutaneous hand muscle that has been described as the most mysterious muscle from a functional and developmental perspective [Kaplan () Kaplan's Functional and Surgical Anatomy of the Hand]. Functionally, the PB is considered to deepen the hollow of the palm and to protect the neurovasculature of the ulnar canal. Although the function of the PB has been inferred from cadaveric observations, the electromyographic (EMG) activity of this muscle has not been explored systematically during specific movements of the hand. The purpose of this study was to record PB intramuscular EMG activity during dynamic grasping tasks, and to quantify the change in PB muscle length (M L ) and thickness (M T ) incurred during maximal contraction using ultrasound imaging. Intramuscular EMG was recorded from the PB in the dominant hands of 12 healthy participants (11 males, one female; age: 27 ± 4 years) during maximal abduction, flexion and opposition of the 5th digit, and two grasping tasks. Abduction of the 5th digit yielded the greatest EMG activity in most individuals (seven out of 11), and produced significantly less PB EMG activity when compared with grasping a cylindrical-shaped object (P = 0.003) but not a spherical-shaped object (P = 0.130). During maximal abduction of the 5th digit, PB M L decreased in both the left (28 ± 11%; P = 0.002) and right (32 ± 5%; P = 0.002) hands. Similarly, a concomitant increase in PB M T was observed in the left (68 ± 30%; P = 0.002) and right (85 ± 44%; P = 0.002) hands during the same contraction. These EMG results indicate that the PB is voluntarily activated during prehensile and non-prehensile movements of the hand with significant changes in muscle architecture. The study supports the preservation of the PB in surgical procedures based on its proposed protective role as a muscular barrier to the neurovasculature within the ulnar canal. © 2017 Anatomical Society.

  14. Long-Term Incisal Relationships After Palatoplasty in Patients With Isolated Cleft Palate.

    Science.gov (United States)

    Odom, Elizabeth B; Woo, Albert S; Mendonca, Derick A; Huebener, Donald V; Nissen, Richard J; Skolnick, Gary B; Patel, Kamlesh B

    2016-06-01

    Various palatoplasty techniques have limited incisions in the hard palate due to concerns that these incisions may limit maxillary growth. There is little convincing long-term evidence to support this. Our purpose is to determine incisal relationships, an indicator for future orthognathic procedure, in patients after repair of an isolated cleft of the secondary palate. Our craniofacial database was used to identify patients aged 10 years or greater with an isolated cleft of the secondary palate who underwent palatoplasty between 1985 and 2002. Data collected included age at palatoplasty and follow-up, cleft type, associated syndrome, Robin sequence, surgeon, repair technique, number of operations, and occlusion. Incisal relationship was determined through clinical observation by a pediatric dentist and orthodontist. Seventy eligible patients operated on by 9 surgeons were identified. Class III incisal relationship was seen in 5 patients (7.1%). Palatoplasty techniques over the hard palate (63 of 70 patients) included 2-flap palatoplasty, VY-pushback, and Von Langenbeck repair. There was an association between class III incisal relationship and syndromic diagnosis (P <0.001). Other study variables were not associated with class III incisal relationships. In patients with an isolated cleft of the secondary palate, there was no association between class III incisal relationship and surgeon, age at repair, cleft type, palatoplasty technique, or number of operations. Increased likelihood of class III incisal relationship was associated primarily with syndromic diagnosis.

  15. Midline versus transverse incision for cesarean delivery in low-income countries

    DEFF Research Database (Denmark)

    Maaløe, Nanna; Aabakke, Anna J M; Secher, Niels J

    2014-01-01

    While transverse incision is the recommended entry technique for cesarean delivery in high-income countries, it is our experience that midline incision is still used routinely in many low-income settings. Accordingly, international guidelines lack uniformity on this matter. Although evidence...... is limited, the literature suggests important advantages of the transverse incision, with lower risk of long-term disabilities such as wound disruption and hernia. Also, potential extra time spent on this incision appears not to impact neonatal outcome. Therefore, we suggest that it is time for a change...

  16. Cosmetic effects of skin-crease camouflage incision versus longitudinal incision following carotid endarterectomy.

    Science.gov (United States)

    Kazimierczak, Arkadiusz; Rybicka, Anita; Rynio, Pawel; Gutowski, Piotr; Wiernicki, Ireneusz

    2018-03-01

    Despite the increasing use of carotid angioplasty and stenting (CAS), carotid endarterectomy (CEA) nonetheless remains a more medically beneficial method of treatment for carotid artery stenosis. Therefore, one possibility for progress within this procedure may be to use minimally invasive carotid surgery, especially when the scar is in plain sight: the use of the natural wrinkles (skin crease) as a camouflage of the skin incision provides significant cosmetic improvements. To compare the cosmetic effects of classic and trans-wrinkle CEA. To assess the distance between the carotid artery bifurcation (CAB) and the skin-crease incision whilst attempting CEA. It was a randomized prospective study with two groups: patients undergoing classic surgery (control group; n = 100) and skin-crease trans-wrinkle camouflaged CEA (study group; n = 100). Follow-up was at 2 months and 1 year. The medical results of the treatment were similar in both groups. The cumulative count of strokes and myocardial infarctions was 0.5% within 30 days, and after one year 3.5% (and 5.5% including cases of death). The superiority of the transverse crease being hidden compared to the conventional longitudinal technique was proven in the Patient and Observer Scar Assessment Scale (POSAS) score, respectively 11.4 ±1.0 vs. 14.1 ±3.4 (p = 0.0001) after 2 months and 13.5 ±2.8 vs. 14.1 ±3.4 (p = 0.039) after a year. Trans-wrinkle incision gives better cosmetic results, can be safely performed in most cases, and offers a comfortable approach during CEA.

  17. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

    Science.gov (United States)

    Dupont-Monod, Sylvère; Labbé, Antoine; Fayol, Nicolas; Chassignol, Alexis; Bourges, Jean-Louis; Baudouin, Christophe

    2009-03-01

    To use anterior segment optical coherence tomography (AS-OCT) to analyze the in vivo architecture of clear corneal incisions after phacoemulsification using different techniques. Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, Paris, France. This prospective observational study analyzed clear corneal incisions used in phacoemulsification. All wounds were evaluated 1 day and 8 days postoperatively by AS-OCT (Visante). Incision architecture and pachymetry at the wound level were analyzed. Thirty-five clear corneal incisions were analyzed. Six eyes had 2.75 mm coaxial phacoemulsification, 19 had 2.20 mm microincision coaxial phacoemulsification, and 10 had 1.30 mm bimanual microincision phacoemulsification. The 1.30 mm incision had a straight-line configuration. The 2.20 mm and 2.75 mm incisions had an arcuate configuration. The angles of incidence of 1.30 mm incisions were greater than those of 2.20 mm incisions (P<.001). All incisions had slight corneal edema limited to the incision area. The edema was slightly greater around 1.30 mm incisions (mean pachymetry 1143 microm +/- 140 [SD]) than around 2.20 mm incisions (mean 1012 +/- 101 microm) (P = .001). Bimanual procedures had satisfactory endothelial apposition in the enlarged areas, where stromal edema was less than that surrounding the unenlarged 1.30 mm incisions. The 3 phacoemulsification techniques induced gaping of the endothelial edge, minor inadequate endothelial apposition, and mild stromal edema in the area of the clear corneal incisions. Bimanual microincision sleeveless phacoemulsification may alter the wound slightly more than coaxial 2.75 mm and microcoaxial 2.20 mm sleeved-tip phacoemulsification.

  18. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  19. Return of the mini

    International Nuclear Information System (INIS)

    Ashmore, C.

    2001-01-01

    Partly as a result of the contentious nature of some large hydroelectric schemes, and continuing deregulation on a global scale, the mini hydro systems are enjoying unprecedented growth. This article discusses the reasons for the increase in demand for mini hydro systems, and describes Alstom Power Hydro's new, integrated 'water-to-wire' renewable energy solution which is a modular system which integrates the hydro-turbine, generator and controls to provide a single optimised product called the Mini-Aqua. The Mini-Aqua can be supplied inside a turnkey package including all civil works. The company is also looking to the future with development of its Powerformer technology for smaller-scale, grid-connected applications

  20. Consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo J. Fonseca D'El Rey

    2007-01-01

    Full Text Available CONTEXTO: A fobia social é um grave transtorno de ansiedade que traz incapacitação e sofrimento. OBJETIVOS: Investigar a consistência interna da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN. MÉTODOS: Foi realizado um estudo da consistência interna do Mini-SPIN em uma amostra de 206 estudantes universitários da cidade de São Paulo, SP. RESULTADOS: A consistência interna do instrumento, analisada pelo coeficiente alfa de Cronbach, foi de 0,81. CONCLUSÕES: Esses achados permitiram concluir que a versão em português do Mini-SPIN exibiu resultados de boa consistência interna, semelhantes aos da versão original em inglês.BACKGROUND: Social phobia is a severe anxiety disorder that brings disability and distress. OBJECTIVES: To investigate the internal consistency of the Portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN. METHODS: We conducted a study of internal consistency of the Mini-SPIN in a sample of 206 college students of the city of São Paulo, SP. RESULTS: The internal consistency of the instrument, analyzed by Cronbach's alpha coefficient, was 0.81. CONCLUSIONS: These findings suggest that the Portuguese version of the Mini-SPIN has a good internal consistency, similar to those obtained with the original English version.

  1. Graphic software ''MiniG'' for the Mini-6

    International Nuclear Information System (INIS)

    Zen, J.

    1984-06-01

    MiniG is a set of subprograms, written and aimed at being used in Fortran for graphic applications in nuclear physics (histograms or point clouds). It includes three representation modes of axis scales (linear, semi-log and squared root), five types of vectors and numerous graphic symbols for spectra representation with or without notation (circle, cross, arrow, triangle, spiral, etc.). It offers also the possibilities of the software ''Plot-10'' of Tektronix, and accept all the types of graphic terminals of SATD connected to Mini-6 [fr

  2. Lateral Erosion Encourages Vertical Incision in a Bimodal Alluvial River

    Science.gov (United States)

    Gran, K. B.

    2015-12-01

    Sand can have a strong impact on gravel transport, increasing gravel transport rates by orders of magnitude as sand content increases. Recent experimental work by others indicates that adding sand to an armored bed can even cause armor to break-up and mobilize. These two elements together help explain observations from a bimodal sand and gravel-bedded river, where lateral migration into sand-rich alluvium breaks up the armor layer, encouraging further incision into the bed. Detailed bedload measurements were coupled with surface and subsurface grain size analyses and cross-sectional surveys in a seasonally-incised channel carved into the upper alluvial fan of the Pasig-Potrero River at Mount Pinatubo, Philippines. Pinatubo erupted in 1991, filling valleys draining the flanks of the volcano with primarily sand-sized pyroclastic flow debris. Twenty years after the eruption, sand-rich sediment inputs are strongly seasonal, with most sediment input to the channel during the rainy season. During the dry season, flow condenses from a wide braided planform to a single-thread channel in most of the upper basin, extending several km onto the alluvial fan. This change in planform creates similar unit discharge ranges in summer and winter. Lower sediment loads in the dry season drive vertical incision until the bed is sufficiently armored. Incision proceeds downstream in a wave, with increasing sediment transport rates and decreasing grain size with distance downstream, eventually reaching a gravel-sand transition and return to a braided planform. Incision depths in the gravel-bedded section exceeded 3 meters in parts of a 4 km-long study reach, a depth too great to be explained by predictions from simple winnowing during incision. Instead, lateral migration into sand-rich alluvium provides sufficient fine sediment to break up the armor surface, allowing incision to start anew and increasing the total depth of the seasonally-incised valley. Lateral migration is recorded in a

  3. The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images

    International Nuclear Information System (INIS)

    Roh, Yang Gyun; Jang, Hyun Seon; Kim, Byung Ock; Kim, Jin Soo

    2006-01-01

    To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1. The statistical analyses were carried out using SPSS 12.0.1. When the maxillary central incisors remained, the mean labial alveolar bone width were 6.81±1.41 mm, 6.46±1.33 mm, and 7.91±1.33 mm. When the maxillary central incisors were missed the mean width were 5.42±2.20 mm, 6.23±2.29 mm, and 7.89±2.13 mm. The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to masal cavity revealed statistically significant difference (P<0.05)

  4. [Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)].

    Science.gov (United States)

    D'El Rey, Gustavo José Fonseca; Matos, Cláudia Wilmor

    2009-01-01

    Social phobia (also known as social anxiety disorder) is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN) in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426) of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version) demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive value of 98.6% and incorrect classification rate of 16.9%. With score of 7 points, was observed an increase in the specificity and positive predictive value (88.6% and 62.7%), while the sensitivity and negative predictive value (84.8% and 96.2%) remained high. The Portuguese version of the Mini-SPIN showed satisfactory psychometric qualities in terms of discriminative validity. In this study, the cut-off of 7, was considered to be the most suitable to screening of the generalized social phobia.

  5. Nuclear management in manual small incision cataract surgery by snare technique

    Directory of Open Access Journals (Sweden)

    Bhattacharya Debasish

    2009-01-01

    Full Text Available Manual small incision cataract surgery has evolved into a popular method of cataract surgery in India. However, in supra hard cataract, bringing out the whole nucleus through the sclerocorneal flap valve incision becomes difficult. A bigger incision required in such cataracts loses its value action, as the internal incision and corneal valve slips beyond the limbus into sclera. Struggling with the supra hard cataracts through a regular small incision. Phacofracture in the anterior chamber becomes a useful option in these cases. In the snare technique, a stainless steel wire loop when lassoed around the nucleus in the anterior chamber constricts from the equator, easily dividing the hardest of the nuclei into two halves. The wire loop constricts in a controlled way when the second cannula of snare is pulled. The divided halves can easily be brought out by serrated crocodile forceps. This nuclear management can be safely performed through a smaller sclerocorneal flap valve incision where the corneal valve action is retained within the limbus without sutures, and the endothelium or the incision is not disturbed. However, the technique requires space in the anterior chamber to maneuver the wire loop and anterior chamber depth more than 2.5 mm is recommended. Much evidence to this wonderful technique is not available in literature, as its popularity grew through live surgical workshops and small interactive conferences.

  6. Watershed-scale modeling of streamflow change in incised montane meadows

    Science.gov (United States)

    Essaid, Hedeff I.; Hill, Barry R.

    2014-01-01

    Land use practices have caused stream channel incision and water table decline in many montane meadows of the Western United States. Incision changes the magnitude and timing of streamflow in water supply source watersheds, a concern to resource managers and downstream water users. The hydrology of montane meadows under natural and incised conditions was investigated using watershed simulation for a range of hydrologic conditions. The results illustrate the interdependence between: watershed and meadow hydrology; bedrock and meadow aquifers; and surface and groundwater flow through the meadow for the modeled scenarios. During the wet season, stream incision resulted in less overland flow and interflow and more meadow recharge causing a net decrease in streamflow and increase in groundwater storage relative to natural meadow conditions. During the dry season, incision resulted in less meadow evapotranspiration and more groundwater discharge to the stream causing a net increase in streamflow and a decrease in groundwater storage relative to natural meadow conditions. In general, for a given meadow setting, the magnitude of change in summer streamflow and long-term change in watershed groundwater storage due to incision will depend on the combined effect of: reduced evapotranspiration in the eroded meadow; induced groundwater recharge; replenishment of dry season groundwater storage depletion in meadow and bedrock aquifers by precipitation during wet years; and groundwater storage depletion that is not replenished by precipitation during wet years.

  7. P A Mini

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. P A Mini. Articles written in Bulletin of Materials Science. Volume 36 Issue 4 August 2013 pp 547-551. Composite supercapacitor electrodes made of activated carbon/PEDOT:PSS and activated carbon/doped PEDOT · T S Sonia P A Mini R Nandhini Kalluri Sujith Balakrishnan ...

  8. Temporal versus Superior Limbal Incision: Any difference in visual ...

    African Journals Online (AJOL)

    Aim: To compare the visual outcome of a superiorly placed limbal incision with a temporal limbal incision in extracapsular cataract surgery. The main outcome measures are visual acuity and the degree of stigmatism based on refraction. Method: A retrospective non randomized comparative study. Medical records of 40 ...

  9. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN) Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN)

    OpenAIRE

    Gustavo José Fonseca D'El Rey; Cláudia Wilmor Matos

    2009-01-01

    A fobia social (também conhecida como transtorno de ansiedade social) é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN) em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426) de um estudo de prevalência de transtornos de ansieda...

  10. Meta-analysis of the effectiveness of surgical scalpel or diathermy in making abdominal skin incisions.

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-02-01

    BACKGROUND: Surgical scalpels are traditionally used to make skin incisions. Diathermy incisions on contrary are less popular among the surgeons. The aim of this meta-analysis was to compare the effectiveness of both techniques and address the common fallacies about diathermy incisions. METHODS: A literature search of MEDLINE and Cochrane databases was done, using the keywords diathermy, cold scalpel, and incisions. Eleven clinical trials comparing both methods of making skin incisions were selected for meta-analysis. The end points compared included postoperative wound infection, pain in first 24 hours after surgery, time taken to complete the incisions, and incision-related blood loss. RESULTS: Postoperative wound infection rate was comparable in both techniques (P = 0.147, odds ratio = 1.257 and 95% CI = 0.923-1.711). Postoperative pain was significantly less with diathermy incisions in first 24 hours (P = 0.031, weighted mean difference = 0.852 and 95% CI = 0.076-1.628). Similarly, the time taken to complete the incision and incision-related blood loss was significantly less with diathermy incisions (95% CI = 0.245-0.502 and 0.548-1.020, respectively). CONCLUSION: Diathermy incisions are equally prone to get wound infection, as do the incisions made with scalpel. Furthermore, lower incidence of early postoperative pain, swiftness of the technique, and a reduced blood loss are the encouraging facts supporting routine use of diathermy for abdominal skin incisions after taking careful precautions.

  11. Single scrotal incision orchidopexy for palpable undescended

    International Nuclear Information System (INIS)

    Ahmad, A.; Safdar, C.A.; Yasir, U.; Rasool, N.; Kanwal, S.; Boota, M.; Rehman, J.U.

    2014-01-01

    To retrospectively asses the results of single scrotal incision orchidopexy (SSIO) performed at our centre with ligation of the patent processus vaginalis in children having palpable undescended testes (UDT). Study Design: Quasi-experimental with retrospective data. Place and Duration of Study: Department of Paediatric surgery Military Hospital Rawalpindi, from April 2007 to December 2011. Patients and Methods: After making a single transverse incision at superior scrotal border, the testis was identified; gubernaculums and the sac were dissected to the highest level and divided. The testis was placed into the scrotum and fixed to the scrotal fascia/skin. All patients were assessed at 2 weeks, 2 months and 6 months post operatively, and then yearly. Results: A total of 38 orchidopexies were performed in 33 patients. The patients age ranged from 14 months to 7 years (mean:2.1 years). Bilateral UDT were found in 5 patients (15.1%). Operative time ranged from 20 to 45 minutes (mean: 36 minutes). The single scrotal incision technique was successful in all 38 cases (100%). All testes were easily fixed in the scrotum. Two patients (5.2%) developed scrotal haematoma and one patient (2.6%) developed stitch abscess. All showed good an atomical and cosmetic results up to a minimum of six months of follow-up. Conclusion: Single scrotal incision orchidopexy for palpable undescended testis is a simple and safe technique. It has shown to consume shorter time and give good cosmetic results. (author)

  12. MiniCNT - A Tabletop Stellarator

    Science.gov (United States)

    Dugan, Chris; Pedersen, Thomas; Berkery, John

    2006-10-01

    MiniCNT is a scaled down version of the Columbia Non-Neutral Torus, a stellarator built to study confinement of non-neutral plasmas on magnetic surfaces. MiniCNT is a glass vacuum chamber capable of holding pressures six orders of magnitude below atmospheric pressure. Unlike CNT, in which plasmas are invisible, MiniCNT allows some collisions with neutrals, causing it to glow. Using two twelve-volt car batteries to power four magnetic coils, MiniCNT generates a 0.02 Tesla magnetic field. While CNT, being larger, is obviously more accurate, there are multiple benefits in MiniCNT. First, it is more flexible and can be adjusted to fit many scenarios easily. The car batteries can be switched for other power sources, the coils can be realigned, and the chamber can be pumped to various pressures of various gases. Also, it is visually accessible; while CNT has glass viewing ports and its plasma is dark, MiniCNT is made of glass and its plasma glows, allowing visualization of the magnetic surfaces.

  13. Mini-Cog and Mini-Mental State Examination: agreement in a cross-sectional study with an elderly sample.

    Science.gov (United States)

    Costa, Diogo; Severo, Milton; Fraga, Sílvia; Barros, Henrique

    2012-01-01

    We aimed to compare the Mini-Mental State Examination (MMSE) with the Mini-Cog, measuring agreement in participants' classification, using a general population sample. Cross-sectional evaluation of 609 community dwellers aged ≥60 years was performed by trained interviewers. Cohen's kappa and 95% confidence intervals (CI) were calculated to assess overall agreement, and Cronbach alphas computed to assess reliability. Two-parameter Item Response Theory models (difficulty and discrimination parameters) were used to assess discrimination. Considering MMSE cut-point for scores Mini-Cog's cut-point score Mini-Cog Mini-Cog Mini-Cog's alpha was 0.2776. Co-calibration according to inherent ability is graphically presented. Agreement between scales seems fragile in our sample. The discriminative and reliability analysis suggests a better performance for subsets of the MMSE compared with the Mini-Cog. Usefulness of calibrated scores is discussed. Copyright © 2012 S. Karger AG, Basel.

  14. [Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture].

    Science.gov (United States)

    Yan, Rongliang; Qu, Jiafu; Cao, Lihai; Liu, Hongda; Chen, Jianghua; Gao, Yan; Peng, Yi

    2018-05-01

    To summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture. Between January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score. All incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%. The procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

  15. Laparoscopic surgery for esophageal achalasia: Multiport vs single-incision approach.

    Science.gov (United States)

    Fukuda, Shuichi; Nakajima, Kiyokazu; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Makino, Tomoki; Kurokawa, Yukinori; Yamasaki, Makoto; Miyata, Hiroshi; Takiguchi, Shuji; Mori, Masaki; Doki, Yuichiro

    2016-02-01

    SILS can potentially improve aesthetic outcomes without adversely affecting treatment outcomes, but these outcomes are uncertain in laparoscopic Heller-Dor surgery. We determined if the degree of patient satisfaction with aesthetic outcomes progressed with the equivalent treatment outcomes after the introduction of a single-incision approach to laparoscopic Heller-Dor surgery. We retrospectively reviewed 20 consecutive esophageal achalasia patients (multiport approach, n = 10; single-incision approach, n = 10) and assessed the treatment outcomes and patient satisfaction with the aesthetic outcomes. In the single-incision approach, thin supportive devices were routinely used to gain exposure to the esophageal hiatus. No statistically significant differences in the operating time (210.2 ± 28.8 vs 223.5 ± 46.3 min; P = 0.4503) or blood loss (14.0 ± 31.7 vs 16.0 ± 17.8 mL; P = 0.8637) were detected between the multiport and single-incision approaches. We experienced no intraoperative complications. Mild dysphagia, which resolved spontaneously, was noted postoperatively in one patient treated with the multiport approach. The reduction rate of the maximum lower esophageal sphincter pressure was 25.1 ± 34.4% for the multiport approach and 21.8 ± 19.2% for the single-incision approach (P = 0.8266). Patient satisfaction with aesthetic outcomes was greater for the single-incision approach than for the multiport approach. When single-incision laparoscopic Heller-Dor surgery was performed adequately and combined with the use of thin supportive devices, patient satisfaction with the aesthetic outcomes was higher and treatment outcomes were equivalent to those of the multiport approach. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  16. MiniDraw

    DEFF Research Database (Denmark)

    2018-01-01

    MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010.......MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010....

  17. Mini-grid Policy Tool-kit. Policy and business frameworks for successful mini-grid roll-outs

    International Nuclear Information System (INIS)

    Franz, Michael; Hayek, Niklas; Peterschmidt, Nico; Rohrer, Michael; Kondev, Bozhil; Adib, Rana; Cader, Catherina; Carter, Andrew; George, Peter; Gichungi, Henry; Hankins, Mark; Kappiah, Mahama; Mangwengwende, Simbarashe E.

    2014-01-01

    The Mini-grid Policy Tool-kit is for policy makers to navigate the mini-grid policy design process. It contains information on mini-grid operator models, the economics of mini-grids, and necessary policy and regulation that must be considered for successful implementation. The publication specifically focuses on Africa. Progress on extending the electricity grid in many countries has remained slow because of high costs of gird-extension and limited utility/state budgets for electrification. Mini-grids provide an affordable and cost-effective option to extend needed electricity services. Putting in place the right policy for min-grid deployment requires considerable effort but can yield significant improvement in electricity access rates as examples from Kenya, Senegal and Tanzania illustrate. The tool-kit is available in English, French and Portuguese

  18. Small incision guarded hydroaspiration of iris lesions.

    Science.gov (United States)

    Singh, Arun D

    2017-11-01

    To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  19. Single incision laparoscopic cholecystectomy using the one-incision three-trocar technique with all straight instruments: how I do it?

    Institute of Scientific and Technical Information of China (English)

    Hongyi Cui

    2011-01-01

    Single incision laparoscopic surgery (SILS) is a novel minimally invasive surgical technique that is gaining popularity around the world.One of the most commonly performed procedures is single incision laparoscopic cholecystectomy (SILC).Most reported techniques utilize special purpose-made access port and articulating instruments,rendering the procedure costly and difficult to learn.This article provides a stepwise description of SILC technique using all straight instruments without the need for a special port.It aims to shorten the learning curve for surgeons wishing to adopt a safe and cost-effective SILC technique to their practice.

  20. Laser incising of wood: Impregnation of columns with water-soluble dye

    International Nuclear Information System (INIS)

    Hattori, N.; Ando, K.; Kitayama, S.; Nakamura, Y.

    1994-01-01

    To know whether or not laser incising is a useful pre-treatment technique in impregnating a chemical fluid into lumber, pin holes were made in columns of hinoki (Chamaecyparis obtusa Endl.), sugi (Cryptomeria japonica D. Don), karamatsu (Larix leptolepis Gordon) and douglas-fir (Pseudo-tsuga menziesii Franco) with 1.7 kW CO2 laser, and a water-soluble dye was impregnated into these columns with a local pressure impregnation device. Retentions, and lengths and widths of penetrations from each hole were measured quantitatively. Referring to the results of the preparatory experiment mentioned above, incising patterns for sugi and douglas-fir were designed, and the same water-soluble dye was impregnated into the laser-incised columns as well as into non-incised ones with the vacuum-pressure method to obtain penetrated layers with the target depths completely. As a result, a retention of 200 kg/m3 of dye could be achieved for a column of douglas-fir even if it is a species difficult to impregnate. The penetrated layer also could be formed completely at the depth of the laser incision. Therefore, it is concluded that laser incising can be used for the pre-treatment before impregnation of wood columns. (author)

  1. Diathermy vs. scalpel skin incisions in general surgery: double-blind, randomized, clinical trial.

    Science.gov (United States)

    Shamim, Muhammad

    2009-08-01

    This prospective, double-blind, randomized, controlled trial was designed to compare the outcome of diathermy incisions versus scalpel incisions in general surgery. A total of 369 patients who underwent diathermy incision (group A: 185 patients) or scalpel incision (group B: 184 patients) were analyzed. Variables analyzed were: surgical wound classification, length and depth of incision, incision time, duration of operation, incisional blood loss, postoperative pain, duration of hospital stay, duration of healing, and postoperative complications. The inclusion criteria were all patients who underwent elective or emergency general surgery. The exclusion criteria were only cases with incomplete patients' data and patients who were lost to follow-up. This study was conducted at Fatima Hospital-Baqai Medical University and Shamsi Hospital (Karachi), from January 2006 to December 2007. Incision time was significantly longer for patients in group B (p = 0.001). Incisional blood loss also was more for patients in group B (p = 0.000). Pain perception was found to be markedly reduced during the first 48 h in group A (p = 0.000). Total period of hospital stay (p = 0.129) and time for complete wound healing (p = 0.683) were almost the same for both groups. Postoperative complication rate by wound classification did not differ markedly between the two groups (p = 0.002 vs. p = 0.000). Diathermy incision has significant advantages compared with the scalpel because of reduced incision time, less blood loss, & reduced early postoperative pain.

  2. Review of mini-clinical evaluation exercise (mini-CEX in a psychiatry clerkship

    Directory of Open Access Journals (Sweden)

    Meresh E

    2018-04-01

    Full Text Available Edwin Meresh,1 David Daniels,2 Aparna Sharma,1 Murali Rao,1 Kaushal Mehta,3 David Schilling1 1Department of Psychiatry and Behavioral Neurosciences, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL, USA; 2Department of Psychiatry, Medstar Georgetown University Hospital, Washington, DC, USA; 3School of Public Health, Stritch School of Medicine, Loyola University Medical Center, Maywood, IL USA Background: Direct observation of medical students with actual patients is important for the assessment of clinical skills including interviewing and counseling skills. This article describes medical students’ experience of mini-clinical evaluation exercise (mini-CEX during their clerkship in consultation psychiatry. Materials and methods: In our center during inpatient consultation psychiatry clerkship, all rotating students are expected to complete one mini-CEX assessment as part of their clinical training. We conducted retrospective analysis of mini-CEX ratings completed from 2013 to 2016. All evaluations took place at inpatient medical setting in patients admitted with medical conditions and psychiatric comorbidities. Results: A total of 113 evaluations were reviewed. The time examiner observed the interaction of a student with the patient was 14.24 minutes (mean, and the time spent in providing feedback to the student was 9.71 minutes. Complexity of problem was rated as low in 0.88% (n=1, moderate in 50.44% (n=57, and high in 48.67% (n=55. Highest ratings were for professionalism, similar to previous reports. Total score calculated by examiner showed no difference by the complexity of the patient; however, we observed a trend in higher counseling score for the high complexity group. Conclusion: Mini-CEX assessment during busy clerkship is feasible with good outcomes. Direct observation of medical trainees with actual patients is important for the assessment of performance-based clinical skills. Hospital psychiatry rotation

  3. Channel incision and suspended sediment delivery at Caspar Creek, Mendocino County, California

    Science.gov (United States)

    Nicholas J. Dewey; Thomas E. Lisle; Leslie M. Reid

    2003-01-01

    Tributary and headwater valleys in the Caspar Creek watershed,in coastal Mendocino County, California,show signs of incision along much of their lengths.An episode of incision followed initial-entry logging which took place between 1860 and 1906. Another episode of incision cut into skid-trails created for second-entry logging in the 1970's.

  4. A study of incisive canal using a cone beam computed tomography

    International Nuclear Information System (INIS)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae

    2004-01-01

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm ± 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm ± 0.76 and 3.89 mm ± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 ± 6.96 and 117.45 ± 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  5. A study of incisive canal using a cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm {+-} 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm {+-} 0.76 and 3.89 mm {+-} 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 {+-} 6.96 and 117.45 {+-} 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  6. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    OpenAIRE

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnos...

  7. A skin abscess model for teaching incision and drainage procedures.

    Science.gov (United States)

    Fitch, Michael T; Manthey, David E; McGinnis, Henderson D; Nicks, Bret A; Pariyadath, Manoj

    2008-07-03

    Skin and soft tissue infections are increasingly prevalent clinical problems, and it is important for health care practitioners to be well trained in how to treat skin abscesses. A realistic model of abscess incision and drainage will allow trainees to learn and practice this basic physician procedure. We developed a realistic model of skin abscess formation to demonstrate the technique of incision and drainage for educational purposes. The creation of this model is described in detail in this report. This model has been successfully used to develop and disseminate a multimedia video production for teaching this medical procedure. Clinical faculty and resident physicians find this model to be a realistic method for demonstrating abscess incision and drainage. This manuscript provides a detailed description of our model of abscess incision and drainage for medical education. Clinical educators can incorporate this model into skills labs or demonstrations for teaching this basic procedure.

  8. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  9. Validação da versão em português do Mini-Inventário de Fobia Social (Mini-SPIN Validation of the portuguese version of the Mini-Social Phobia Inventory (Mini-SPIN

    Directory of Open Access Journals (Sweden)

    Gustavo José Fonseca D'El Rey

    2009-12-01

    Full Text Available A fobia social (também conhecida como transtorno de ansiedade social é um grave transtorno mental que traz sofrimento e incapacitação. O objetivo deste estudo foi validar para a língua portuguesa o Mini-Inventário de Fobia Social (Mini-SPIN em uma amostra da população. Foi realizado um estudo da validade discriminativa do Mini-SPIN em uma amostra de 644 pessoas (grupo positivo para o Mini-SPIN: n = 218 e grupo controle/negativo: n = 426 de um estudo de prevalência de transtornos de ansiedade na cidade de Santo André (SP. A versão em português do Mini-SPIN (com escore de 6 pontos, sugerido na versão original em inglês demonstrou uma sensibilidade de 95,0%, especificidade de 80,3%, valor preditivo positivo de 52,8%, valor preditivo negativo de 98,6% e taxa de classificação incorreta de 16,9%. Com escores de 7 pontos, foi observado um aumento na especificidade e no valor preditivo positivo (88,6% e 62,7%, sendo que a sensibilidade e o valor preditivo negativo (84,8% e 96,2% mantiveram-se altos. A versão em português do Mini-SPIN apresentou qualidades psicométricas satisfatórias em termos de validade discriminativa. Neste estudo, o ponto de corte igual a 7 mostrou-se mais adequado para a identificação da fobia social generalizada.Social phobia (also known as social anxiety disorder is a severe mental disorder that brings distress and disability. The aim of this study was validate to the Portuguese language the Mini-Social Phobia Inventory (Mini-SPIN in a populational sample. We performed a discriminative validity study of the Mini-SPIN in a sample of 644 subjects (Mini-SPIN positive group: n = 218 and control/negative group: n = 426 of a study of anxiety disorders' prevalence in the city of Santo André-SP. The Portuguese version of the Mini-SPIN (with score of 6 points, suggested in the original English version demonstrated a sensitivity of 95.0%, specificity of 80.3%, positive predictive value of 52.8%, negative predictive

  10. Adjustable mini-sling compared to conventional mid-urethral slings in women with urinary incontinence

    DEFF Research Database (Denmark)

    Rudnicki, Martin; von Bothmer-Ostling, Katarina; Holstad, Anja

    2017-01-01

    INTRODUCTION: The primary aim was to compare the objective and subjective outcomes and short-term complication rates of an adjustable single-incision mini-sling (SIMS) versus standard mid-urethral slings (SMUS). The secondary aim was reporting pain perception and complications at one-year follow......-up. MATERIAL AND METHODS: The study was designed as a multicenter prospective randomized trial where women were included by eight centers in Denmark, Norway and Sweden. The trial was registered at ClinicalTrials. gov: NCT01754558. A total of 305 women less than 60 years old with verified stress urinary...... incontinence were included. All women were randomized to SIMS (Ajust(®) ; N=155) or SMUS (TVT, TVT-O or TOT; N=150) and were evaluated by stress test and bladder diary before and after surgery and symptoms related to incontinence using ICIQ-SF, PISQ-12 and PGI-S and PGI-I. Objective cure was defined...

  11. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  12. Superficial parotidectomy via facelift incision

    NARCIS (Netherlands)

    Lohuis, Peter J. F. M.; Tan, M. Liane; Bonte, Katrien; van den Brekel, Michiel W. M.; Balm, Alfons J. M.; Vermeersch, Hubert B.

    2009-01-01

    The stigma of a visually prominent facial scar following parotid surgery can be distressing to a young patient. The surgical technique of parotidectomy via a facelift incision is described and evaluated. Thirty patients with a benign lesion of the parotid gland underwent a partial superficial

  13. De Qeurvian Tenosynovitis: Clinical Outcomes of Surgical Treatment with Longitudinal and Transverse Incision

    Directory of Open Access Journals (Sweden)

    Arefah Dehghani Tafti

    2011-03-01

    Full Text Available AbstractObjectives: De Quervain disease is a mechanical tenosynovitis due to inadequacy volume between abductor pollicis longus, extensor pollicis brevis and their tunnel. Treatment methods include immobilization, steroid injections, and operation. For the first time Fritz De Quervain described surgical treatment of this disease. Since then, various ways of treatment have been reported. The purpose of this study is to compare the clinical outcomes of a longitudinal incision with a transverse incision in De Quervain disease.Methods: This was a randomized controlled clinical trial conducted in three hospitals in Iran, Yazd from March 2003 to September 2008. One hundred-twenty patients with De Quervain disease who did not respond to conservative treatment were operated with two different incisions. The patients were followed for three months to compare the surgical outcomes.Results: During a three month follow-up, a significant difference was shown between the two methods (p=0.03. Results of surgical treatment with longitudinal incision were excellent (only 5 hypertrophic scars, but there were 13 postoperative complaints with transverse incision.Conclusion: According to our findings, longitudinal incision in surgical treatment of De Quervain disease is better than transverse incision.

  14. Does pilonidal abscess heal quicker with off-midline incision and drainage?

    Science.gov (United States)

    Webb, P M; Wysocki, A P

    2011-06-01

    No clinical trials have been done to guide the surgeon in the optimal technique of draining a pilonidal abscess. The aim of our study was to investigate whether the location of the incision influences wound healing. Electronic records from the surgical database at our 200-bed district general hospital were reviewed for operative technique (midline vs. lateral) for patients who underwent incision and drainage for acute pilonidal abscess between January 2003 and February 2010. These patients were admitted from the Emergency Department with a pilonidal abscess, underwent operative drainage, and returned for follow-up. The main outcome measure was wound healing time. Two hundred and forty-three pilonidal abscesses were drained, 134 with a lateral and 74 with a midline incision. All patients underwent simple longitudinal incision. No patient underwent de-roofing, marsupialisation, or closure. Forty-eight patients with midline drainage who returned for follow-up were matched for gender, age, and microbiology culture results with patients who underwent lateral drainage. Almost all were drained under general anesthesia with a median postoperative stay of 1 day. The overall length of follow-up was the same in both groups (P = 0.13). Abscesses that did not heal were followed-up for the same period of time irrespective of incision type (P = 0.48). Abscesses that healed after midline incision took approximately 3 weeks longer than those drained via a lateral incision (P = 0.02). Our study has limitations since it was a retrospective study that did not capture patients whose abscess drained spontaneously or were drained in the emergency department. Pilonidal abscess should be drained away from the midline.

  15. Mini-flank supra-12th rib incision for open partial nephrectomy for renal tumor with RENAL nephrometry score ≥10: an innovation of traditional open surgery.

    Science.gov (United States)

    Wang, Hang; Sun, Li-an; Wang, Yiwei; Xiang, Zhuoyi; Zhou, Lin; Guo, Jianming; Wang, Guomin

    2015-04-01

    The skill of supra-12th rib mini-flank approach for open partial nephrectomy (MI-OPN) provides an advanced operative method for renal tumor. Compared with laparoscopic and robotic surgery, it may be a feasible selection for the complex renal tumors. We describe our techniques and results of MI-OPN in complex renal tumors with high RENAL nephrometry score (RENAL nephrometry score ≥10). Fifty-five patients diagnosed with renal tumors between January 2009 and July 2013 were included in this study. Eligibility criteria comprised of patients with complex renal tumor (RENAL score ≥10) being candidates for partial nephrectomy (PN). All patients received MI-OPN and all surgeries were performed by a single urologist. The preoperative workup comprised of medical history, physical examination, and routine laboratory tests. Serum creatinine was recorded preoperatively and 2 to 3 months after operation. Operative time, ischemia time, blood loss, operative and postoperative complications, renal function, and pathology parameters were recorded. MI-OPN was successfully performed in all cases. Mean tumor size was 4.7 cm (range: 2.5-8.1). Mean warm ischemia time was 28.1 minutes (range: 21-39), mean operative time was 105 minutes (range: 70-150) and mean estimated blood loss was 68 mL (range: 10-400). Mean postoperative hospital stay was 6.5 days (range: 5-12). Postoperative complications were found in 3 patients (5.5%). The mean pre- and postoperative serum creatinine levels were 76.2 μmol/L (range: 47-132) and 87.1 μmol/L (range: 61-189) with significant difference (P = 0.004). The mean pre- and postoperative estimated glomerular filtration rate (eGFR) were 91.5 (range: 34-133) and 82.5 (range: 22-126.5), respectively with significant difference (P = 0.024). In an average follow-up of 19.9 months (range: 8-50), no local recurrence or systemic progression occurred. In conclusion, MI-OPN can combine the benefits of both minimal invasive and traditional open

  16. Spurious RF signals emitted by mini-UAVs

    NARCIS (Netherlands)

    Schleijpen, R.; Voogt, V.; Zwamborn, P.; Oever, J. van den

    2016-01-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to

  17. Systematic review and meta-analysis of electrocautery versus scalpel for surgical skin incisions.

    Science.gov (United States)

    Aird, Lisa N F; Brown, Carl J

    2012-08-01

    The creation of surgical skin incisions has historically been performed using a cold scalpel. The use of electrocautery for this purpose has been controversial with respect to patient safety and surgical efficacy. A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted to compare skin incisions made by electrocautery and a scalpel. A systematic electronic literature search was performed using 2 electronic databases (MEDLINE and PubMed), and the methodological quality of included publications was evaluated. Six RCTs were identified comparing electrocautery (n = 606) and a scalpel (n = 628) for skin incisions. No significant difference in wound infection rates or scar cosmesis was identified between the treatment groups. Electrocautery significantly reduced the incision time and postoperative wound pain. A trend toward less incisional blood loss from skin incisions made with electrocautery was noted. Electrocautery is a safe and effective method for performing surgical skin incisions. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  19. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  1. The results of arthroscopic versus mini-open repair for rotator cuff tears at mid-term follow-up

    Directory of Open Access Journals (Sweden)

    Ibrahim Khalid A

    2007-12-01

    Full Text Available Abstract Background To prospectively evaluate patients who underwent a "mini-open" repair versus a completely arthroscopic technique for small to large size rotator cuff tears. Methods Fifty-two patients underwent "mini-open" or all arthroscopic repair of a full thickness tear of the rotator cuff. Patients who complained of shoulder pain and/or weakness and who had failed a minimum of 6 weeks of physical therapy and had at least one sub-acromial injection were surgical candidates. Pre and post-operative clinical evaluations included the following: 1 demographics; 2 Simple Shoulder Test (SST; 3 University of California, Los Angeles (UCLA rating scale; 4 visual analog pain assessment (VAS; and 5 pre-op SF12 assessment. Descriptive analysis was performed for patient demographics and for all variables. Pre and post outcome scores, range of motion and pain scale were compared using paired t-tests. Analysis of variance (ANOVA was used to evaluate any effect between dependent and independent variables. Significance was set at p is less than or equal to 0.05. Results There were 31 females and 21 males. The average follow-up was 50.6 months (27 – 84 months. The average age was similar between the two groups [arthroscopic x = 55 years/mini-open x = 58 years, p = 0.7]. Twenty-seven patients underwent arthroscopic repair and 25 underwent repair with a mini-open incision. The average rotator cuff tear size was 3.1 cm (range: 1–5 centimeters. There was no significant difference in tear size between the two groups (arthroscopic group = 2.9 cm/mini-open group = 3.2 cm, p = 0.3. Overall, there was a significant improvement from pre-operative status in shoulder pain, shoulder function as measured on the Simple Shoulder test and UCLA Shoulder Form. Visual analog pain improved, on average, 4.4 points and the most recent Short Shoulder Form and UCLA scores were 8 and 26 respectively. Both active and passive glenohumeral joint range of motion improved

  2. Psychometric Evaluation of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID).

    Science.gov (United States)

    Duncan, Laura; Georgiades, Kathy; Wang, Li; Van Lieshout, Ryan J; MacMillan, Harriet L; Ferro, Mark A; Lipman, Ellen L; Szatmari, Peter; Bennett, Kathryn; Kata, Anna; Janus, Magdalena; Boyle, Michael H

    2017-12-04

    The goals of the study were to examine test-retest reliability, informant agreement and convergent and discriminant validity of nine DSM-IV-TR psychiatric disorders classified by parent and youth versions of the Mini International Neuropsychiatric Interview for Children and Adolescents (MINI-KID). Using samples drawn from the general population and child mental health outpatient clinics, 283 youth aged 9 to 18 years and their parents separately completed the MINI-KID with trained lay interviewers on two occasions 7 to 14 days apart. Test-retest reliability estimates based on kappa (κ) went from 0.33 to 0.79 across disorders, samples and informants. Parent-youth agreement on disorders was low (average κ = 0.20). Confirmatory factor analysis provided evidence supporting convergent and discriminant validity. The MINI-KID disorder classifications yielded estimates of test-retest reliability and validity comparable to other standardized diagnostic interviews in both general population and clinic samples. These findings, in addition to the brevity and low administration cost, make the MINI-KID a good candidate for use in epidemiological research and clinical practice. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Cochlear implantation with Pulsar Med El: a novel small incision technique.

    Science.gov (United States)

    Cuda, D

    2009-04-01

    Although still widely implanted, Pulsar Med-El is rarely considered for small incision approach. Overall, 30 teen-age and adult patients were operated upon with a novel small incision (4-5 cm). Full insertion of the electrode array was achieved in all cases. No major intra-operative complications occurred. At follow-up, no flap-related complications and no migration of the receiver-stimulator were observed in the "device suture" (14 patients) or "no device suture" groups (16 patients). All patients are full-time users of the device. In conclusion, a small incision for the Pulsar Med-El cochlear implant is feasible, safe and reproducible. Ligature fixation of the device is not critical with this operation. Also with this device, in adult and teen-age patients, it is, therefore, possible to retain several typical advantages of small incision approaches.

  4. Temperature-controlled laser-soldering system and its clinical application for bonding skin incisions

    Science.gov (United States)

    Simhon, David; Gabay, Ilan; Shpolyansky, Gregory; Vasilyev, Tamar; Nur, Israel; Meidler, Roberto; Hatoum, Ossama Abu; Katzir, Abraham; Hashmonai, Moshe; Kopelman, Doron

    2015-12-01

    Laser tissue soldering is a method of repairing incisions. It involves the application of a biological solder to the approximated edges of the incision and heating it with a laser beam. A pilot clinical study was carried out on 10 patients who underwent laparoscopic cholecystectomy. Of the four abdominal incisions in each patient, two were sutured and two were laser soldered. Cicatrization, esthetical appearance, degree of pain, and pruritus in the incisions were examined on postoperative days 1, 7, and 30. The soldered wounds were watertight and healed well, with no discharge from these wounds or infection. The total closure time was equal in both methods, but the net soldering time was much shorter than suturing. There was no difference between the two types of wound closure with respect to the pain and pruritus on a follow-up of one month. Esthetically, the soldered incisions were estimated as good as the sutured ones. The present study confirmed that temperature-controlled laser soldering of human skin incisions is clinically feasible, and the results obtained were at least equivalent to those of standard suturing.

  5. [Bone remodeling and modeling/mini-modeling.

    Science.gov (United States)

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  6. The MiniBooNE Detector

    OpenAIRE

    MiniBooNE Collaboration

    2008-01-01

    The MiniBooNE neutrino detector was designed and built to look for muon-neutrino to electron-neutrino oscillations in the mixing parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  7. A DNA mini-barcode for land plants.

    Science.gov (United States)

    Little, Damon P

    2014-05-01

    Small portions of the barcode region - mini-barcodes - may be used in place of full-length barcodes to overcome DNA degradation for samples with poor DNA preservation. 591,491,286 rbcL mini-barcode primer combinations were electronically evaluated for PCR universality, and two novel highly universal sets of priming sites were identified. Novel and published rbcL mini-barcode primers were evaluated for PCR amplification [determined with a validated electronic simulation (n = 2765) and empirically (n = 188)], Sanger sequence quality [determined empirically (n = 188)], and taxonomic discrimination [determined empirically (n = 30,472)]. PCR amplification for all mini-barcodes, as estimated by validated electronic simulation, was successful for 90.2-99.8% of species. Overall Sanger sequence quality for mini-barcodes was very low - the best mini-barcode tested produced sequences of adequate quality (B20 ≥ 0.5) for 74.5% of samples. The majority of mini-barcodes provide correct identifications of families in excess of 70.1% of the time. Discriminatory power noticeably decreased at lower taxonomic levels. At the species level, the discriminatory power of the best mini-barcode was less than 38.2%. For samples believed to contain DNA from only one species, an investigator should attempt to sequence, in decreasing order of utility and probability of success, mini-barcodes F (rbcL1/rbcLB), D (F52/R193) and K (F517/R604). For samples believed to contain DNA from more than one species, an investigator should amplify and sequence mini-barcode D (F52/R193). © 2013 John Wiley & Sons Ltd.

  8. Mouse preferential incising force orientation changes during jaw closing muscle hyperalgesia and is sex dependent.

    Science.gov (United States)

    Widmer, C G; Morris-Wiman, J

    2016-12-01

    Mouse incising is controlled by a central pattern generator and this activity can change in the presence of pain. The incising frequency and maximum force generation decreases with pain. In this study, we used repetitive acidic injections in the left masseter muscle of male and female mice to determine differences between baseline and jaw muscle pain conditions and the effect of sex on preferential incising direction. A within subject design was used to evaluate data previously acquired using multi-axis force data (X, Y and Z) from the 4th baseline recording day and day 7 post-injection (day of maximal pain response) for each mouse of each sex. A total of 34 female and male (age 3-9months) CD-1 mice were evaluated. After mathematically rotating the X and Y axes to align the Y axis to be parallel to the wire struts of the cage top, data were analyzed to determine incising direction preference during baseline (non-pain) and pain (day 7) conditions and between sex. Radar plots of X-Y, X-Z and Y-Z axes depicted the average direction of incising preference between baseline and pain conditions for each sex. Statistical differences among groups were tested using a mixed model ANOVA. Similar to previous findings, female mice had a more robust difference in incising direction preference when comparing male and female pain conditions and this was most evident in the X-Z axes. The incising frequencies most commonly affected were 5.3, 6.2 and 7.6Hz. Male mice varied little in their incising direction preference between the baseline and pain conditions. In addition, statistical comparison of ratios of the percent of time spent incising in the Z versus X axes for each incising frequency found that the incising preference was not different when comparing 5.3 and 7.6Hz frequencies. Finally, female mice used a novel approach to minimize pain while incising by rotating their head and body nearly 180 degrees while males did not use this strategy as frequently. The preferred incising

  9. Frequency of palmaris longus absence and its association with other anatomical variations in the Egyptian population.

    Science.gov (United States)

    Raouf, Hoda Abdel; Kader, Ghada Abdel; Jaradat, Ahmed; Dharap, Amol; Fadel, Raouf; Salem, Abdel Halim

    2013-07-01

    The palmaris longus (PL) is one of the most variable muscles in the human body. Racial differences in its variation have been documented. Several studies have attempted to correlate PL absence with other anatomical variations. This study was conducted to determine the prevalence of absence of PL, correlate it with gender and body side and to determine its association with other anatomical variations in the Egyptian population. The presence of PL was clinically determined in 386 Egyptians using the standard technique. All subjects were examined for the presence of the flexor digitorum superficialis (FDS) to the fifth finger. Allen's test was done to assess the completeness of the superficial palmar arch (SPA). The overall prevalence of absence of the PL in Egyptian subjects was 50.8%. There was no significant difference in PL absence with regard to the body side but a significant difference was seen as regards gender and when bilateral absence of PL was compared to its unilateral absence. Absence of FDS tendon to the fifth finger was seen in 1.3% subjects. There was no association between the absence of the FDS tendon to the fifth finger and either presence or absence of PL and also between the absence of PL and the incompleteness of SPA in both genders. In conclusion, the prevalence of absence of PL in the Egyptian population represents one of the highest rates of absence to be reported for this muscle, which is significantly different from that in other ethnic groups. Copyright © 2013 Wiley Periodicals, Inc.

  10. Relaxation incisions of venomous snake "Japanese mamushi" bites to the hand

    Directory of Open Access Journals (Sweden)

    Sugamata A

    2011-12-01

    Full Text Available Akira Sugamata, Naoki Yoshizawa, Takahiro OkadaDepartment of Plastic and Reconstructive Surgery, Tokyo Medical University Hachioji Medical Center, Tokyo, JapanAbstract: Gloydius blomhoffii, commonly known as Japanese mamushi, is a venomous viper species found widely in Japan. The most frequently bitten regions are the fingers and toes, and severe swelling causes compression of peripheral arteries and/or compartment syndrome of the extremities. We experienced four cases of mamushi bites to the hand, and undertook relaxation incision in the hands of three of these patients. As a result, the patients who underwent relaxation incision did not show any skin necrosis or permanent sensory disturbance in the affected fingers. Relaxation incision can be useful to not only decompress subcutaneous and compartment pressure of the hand, but also to wash out the venom from the bitten region by improving venous and lymphatic drainage.Keywords: mamushi, snakebite, viper, relaxation incision

  11. Camouflage of Severe Skeletal Class II Gummy Smile Patient Treated Nonsurgically with Mini Implants

    Directory of Open Access Journals (Sweden)

    Irfan Qamruddin

    2014-01-01

    Full Text Available Skeletal class II has always been a challenge in orthodontics and often needs assistance of surgical orthodontics in nongrowing patients when it presents with severe discrepancy. Difficulty increases more when vertical dysplasia is also associated with sagittal discrepancy. The advent of mini implants in orthodontics has broadened the spectrum of camouflage treatment. This case report presents a 16-year-old nongrowing girl with severe class II because of retrognathic mandible, and anterior dentoalveolar protrusion sagittally and vertically resulted in severe overjet of 13 mm and excessive display of incisors and gums. Both maxillary central incisors were trimmed by general practitioner few years back to reduce visibility. Treatment involved use of micro implant for retraction and intrusion of anterior maxillary dentoalveolar segment while lower incisors were proclined to obtain normal overjet, and overbite and pleasing soft tissue profile. Smile esthetics was further improved with composite restoration of incisal edges of both central incisors.

  12. Towards achieving small-incision cataract surgery 99.8% of the time.

    Directory of Open Access Journals (Sweden)

    Thomas R

    2000-01-01

    Full Text Available A surgical approach designed to reliably attain the modern goal of small incision cataract surgery 99.8% of the time is described. Phacoemulsification as well as a manual small incision technique is utilised to achieve the desired outcome as often as possible and for all types of cataracts. The logic, and required surgical steps are described and illustrated. This surgical technique allows the advantages of small incision surgery to be reliably achieved. The method is flexible and allows decisions and steps to be modified depending on the skill and comfort zone of the individual surgeon.

  13. Circumareolar incision-subdermal tunneling dissection for excision of multiple breast fibroadenomata

    Directory of Open Access Journals (Sweden)

    S O Agodirin

    2017-01-01

    Full Text Available Excision of multiple fibroadenomas (MF in separate breast quadrants presents difficulties of number and location of incision(s and extent of tissue dissection and may be associated with more complications and poorer cosmetic outcome. This is a report of excision of MF in multiple quadrants of the breast using a modification of subcutaneous dissection technique dubbed the circumareolar incision and subdermal tunneling (CAST dissection. After exposure of the superficial fascia with circumareolar incision, subdermal cone-wise dissection was made to allow mobilization of the segment bearing the lump(s. The lump(s were enucleated and removed. MF were removed from four breasts in three young unmarried females. The first patient had multiple adenomas removed from three quadrants of both breasts: 14 on the right and six on the left. The second patient had excision of three lumps in three separate quadrants, and the third patient had excision of two lumps in two separate quadrants. All patients had edema and bruising. One breast had wound infection and dehiscence. There were no skin necrosis, no nipple loss, and no breast distortion. All ensuing scars were camouflaged. CAST dissection was used for excision of MF in multiple quadrants of the breast with preservation of excellent cosmetic outcome of a single circumareolar incision.

  14. The MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bartoszek, L.M.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Green, C.; Green, J.A.

    2009-01-01

    The MiniBooNE neutrino detector was designed and built to look for ν μ →ν e oscillations in the (sin 2 2θ,Δm 2 ) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  15. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  16. Incision extension is the optimal method of difficult gallbladder extraction at laparoscopic cholecystectomy.

    Science.gov (United States)

    Bordelon, B M; Hobday, K A; Hunter, J G

    1992-01-01

    An unsolved problem of laparoscopic cholecystectomy is the optimal method of removing the gallbladder with thick walls and a large stone burden. Proposed solutions include fascial dilatation, stone crushing, and ultrasonic, high-speed rotary, or laser lithotripsy. Our observation was that extension of the fascial incision to remove the impacted gallbladder was time efficient and did not increase postoperative pain. We reviewed the narcotic requirements of 107 consecutive patients undergoing laparoscopic cholecystectomy. Fifty-two patients required extension of the umbilical incision, and 55 patients did not have their fascial incision enlarged. Parenteral meperidine use was 39.5 +/- 63.6 mg in the patients requiring fascial incision extension and 66.3 +/- 79.2 mg in those not requiring fascial incision extension (mean +/- standard deviation). Oral narcotic requirements were 1.1 +/- 1.5 doses vs 1.3 +/- 1.7 doses in patients with and without incision extension, respectively. The wide range of narcotic use in both groups makes these apparent differences not statistically significant. We conclude that protracted attempts at stone crushing or expensive stone fragmentation devices are unnecessary for the extraction of a difficult gallbladder during laparoscopic cholecystectomy.

  17. Transverse versus Longitudinal Incisions for Femoral Artery Exposure in Treating Patients with Peripheral Vascular Disease.

    Science.gov (United States)

    Parikh, Punam P; Rubio, Gustavo A; Patel, Kunal; Gupta, Kapil; Jones, Keith; Rey, Jorge; Robinson, Handel

    2018-02-01

    This study evaluates differences in wound complication rate when transverse versus longitudinal incision is utilized to expose femoral vessels in managing patients with peripheral vascular disease. A retrospective review from 2013 to 2015 was conducted of 150 patients undergoing 156 lower extremity revascularizations with femoral artery exposure through a groin incision. Patients were stratified into 2 groups, transverse versus longitudinal groin incision. Data were reviewed for 3 surgeons that utilize either transverse or longitudinal groin incision in patients undergoing common or iliofemoral endarterectomies, or where femoral artery was used as inflow and/or outflow vessel for limb revascularization. Each group had a comparative outcomes analysis based on incision type. The primary outcome was wound complication, defined as any wound infection, lymphocele, hematoma, dehiscence, pseudoaneurysm, or necrosis. Other outcomes studied included unplanned return to operating room for wound complication, wound vacuum therapy, and soft-tissue flap closure. Data were analyzed using 2-tailed chi-squared test and Student's t-test. Patients in the transverse (n = 85 cases) versus longitudinal (n = 71 cases) cohorts were similar in relation to demographics and comorbidities. Overall mean follow-up was 220 days. Patients with a transverse as compared to longitudinal incision had a significantly lower overall wound complication rate, 7% vs. 42%, respectively (P transverse incisions were associated with lower incidence of unplanned return to the operating room to manage wound complications than patients with a longitudinal incision (5% vs. 23%, respectively; P Transverse versus longitudinal incisions were also associated with significantly lower need for wound vacuum therapy (6% vs. 15%, respectively; P Transverse groin incisions for femoral artery exposure may offer a lower risk of wound complications for open procedures as compared to a longitudinal incision

  18. Design guidelines for mini-roundabouts

    CSIR Research Space (South Africa)

    Emslie, I

    1997-03-01

    Full Text Available Guidelines for Traffic Calming. Concepts and principles relating to the use of mini-roundabouts as a form of intersection control and in the traffic calming context are discussed. Warrants for the implementation of mini-roundabouts and design standards...

  19. MiniBooNE Oscillation Results

    International Nuclear Information System (INIS)

    Djurcic, Zelimir

    2009-01-01

    These proceedings summarize the MiniBooNE ν μ → ν e results, describe the first (bar ν) μ → (bar ν) e result, and current analysis effort with the NuMI neutrinos detected in the miniBooNE detector

  20. Discussion on the Relevant Factors of General Surgery Incision Infection and Prevention Methods

    Directory of Open Access Journals (Sweden)

    Jin Baotao

    2017-01-01

    Full Text Available There are many reasons that can lead to incision infection of general surgical patients. The main reasons include weight, age, body albumin level, surgical time, observation ward, etc. This paper analyzes the clinic data of patients with incision infection after general surgery based on clinic practice and study on the reasons that have impact on general surgical incision infection and gives relevant prevention countermeasures.

  1. Recent, climate-driven river incision rate fluctuations in the Mercantour crystalline massif, southern French Alps

    Science.gov (United States)

    Petit, C.; Goren, L.; Rolland, Y.; Bourlès, D.; Braucher, R.; Saillard, M.; Cassol, D.

    2017-06-01

    We present a new geomorphological analysis of the Tinée River tributaries in the southern French Alps based on numerical inverse and forward modelling of their longitudinal profiles. We model their relative uplift history with respect to the main channel, hence the incision rate history of this channel. Inverse models show that all tributaries have consistent incision rate histories with alternating high and low values. A comparison with global temperature curves shows that these variations correlate with quaternary climate changes. We suggest that during warm periods, a wave of regressive erosion propagates in the Tinée River, while its tributaries deeply incise their substratum to catch up with the falling base-level. We also show that the post 140 ka history of this landscape evolution is dominated by fluvial incision. We then perform forward models of river incision and simulate the incision of the Tinée River system over a time span of 600 ka. This model allows us to extract time and space incision rate variations of the Tinée River. With a background of a few mm.yr-1, incision rate can increase up to more than 1 cm yr-1 during short periods of time due to climatic oscillations. This result is compatible with published cosmogenic nuclide based dating, which evidenced incision rates from 0.2 to 24 mm yr-1. The part of the channel located between 12 and 20 km downstream from the source has undergone several periods of rapid incision rates, which could explain the steep hillslopes and the triggering of a landslide ∼10 ka ago.

  2. [External periareolar incision for subdermal mastectomy in men with gynecomastia].

    Science.gov (United States)

    Montiel-Jarquín, Alvaro; Reyes-Páramo, Pedro; Ramos-Alvarez, Gloria; López-Colombo, Aurelio; Tinajero-Esquivel, Magdalena; Ruiz-León, Betzabé

    2007-01-01

    Gynecomastia describes a benign increase of the mammary gland in men. When medical treatment fails, symptoms and psychological alterations persist. Subdermal mastectomy is the definitive treatment and can be achieved by different incisions, each with potential complications. We undertook this study to present clinical characteristics of 11 patients with gynecomastia and the results obtained with subdermal mastectomy by means of external periareolar incision. A descriptive cohort study in male patients with gynecomastia was carried out in a third-level medical care hospital. Patients were treated with subdermal mastectomy by means of external periareolar incision. There were 11 male patients with an average age of 19 years (range: 11-60 years), 3 patients (27.2%) with bilateral gynecomastia and 8 patients (72.7%) with unilateral gynecomastia. Average time of evolution was 22 months (range: 16-48 months), 9 patients (81.8%) reported pain, 11 patients (100%) reported psychological alterations with cutaneous alteration, 11 patients (100%) had normal secondary sexual characteristics, 1 patient (9%) had supernumerary nipple development, and 11 patients (100%) had well-defined lesions. According to Simon's classification: seven patients (63.6%) were classified as grade 1, three patients (27.2%) as grade 2 and one patient (9.09%) as grade 3. Each patient had a subdermal mastectomy with external periareolar incision, 11 patients (100%) had a histopathological report of gynecomastia; 1 patient (9.09%) displayed keloid healing and none displayed complications inherent to the surgical procedure. Mastectomy by means of external periareolar incision is useful in the treatment of gynecomastia.

  3. Incision of the Jezero Crater Outflow Channel by Fluvial Sediment Transport

    Science.gov (United States)

    Holo, S.; Kite, E. S.

    2017-12-01

    Jezero crater, the top candidate landing site for the Mars 2020 rover, once possessed a lake that over-spilled and eroded a large outflow channel into the Eastern rim. The Western deltaic sediments that would be the primary science target of the rover record a history of lake level, which is modulated by the inflow and outflow channels. While formative discharges for the Western delta exist ( 500 m3/s), little work has been done to see if these flows are the same responsible for outflow channel incision. Other models of the Jezero outflow channel incision assume that a single rapid flood (incision timescales of weeks), with unknown initial hydraulic head and no discharge into the lake (e.g. from the inflow channels or the subsurface), incised an open channel with discharge modulated by flow over a weir. We present an alternate model where, due to an instability at the threshold of sediment motion, the incision of the outflow channel occurs in concert with lake filling. In particular, we assume a simplified lake-channel-valley system geometry and that the channel is hydraulically connected to the filling/draining crater lake. Bed load sediment transport and water discharge through the channel are quantified using the Meyer-Peter and Mueller relation and Manning's law respectively. Mass is conserved for both water and sediment as the lake level rises/falls and the channel incises. This model does not resolve backwater effects or concavity in the alluvial system, but it does capture the non-linear feedbacks between lake draining, erosion rate, channel flow rate, and slope relaxation. We identify controls on incision of the outflow channel and estimate the time scale of outflow channel formation through a simple dynamical model. We find that the observed 300m of channel erosion can be reproduced in decades to centuries of progressive bed load as the delta forming flows fill the lake. This corresponds to time scales on the order of or smaller than the time scale

  4. Diagnostic validity Polish language version of the questionnaire MINI-KID (Mini International Neuropsychiatry Interview for Children and Adolescent).

    Science.gov (United States)

    Adamowska, Sylwia; Sylwia, Adamowska; Adamowski, Tomasz; Tomasz, Adamowski; Frydecka, Dorota; Dorota, Frydecka; Kiejna, Andrzej; Andrzej, Kiejna

    2014-10-01

    Since over forty years structuralized interviews for clinical and epidemiological research in child and adolescent psychiatry are being developed that should increase validity and reliability of diagnoses according to classification systems (DSM and ICD). The aim of the study is to assess the validity of the Polish version of MINI-KID (Mini International Neuropsychiatric Interview for Children and Adolescents) in comparison to clinical diagnosis made by a specialist in the field of child and adolescent psychiatry. There were 140 patients included in the study (93 boys, 66.4%, mean age 11.8±3.0 and 47 girls 33.5%, mean age 14.0±2.9). All the patients were diagnosed by the specialist in the field of child and adolescent psychiatry according to ICD-10 criteria and by the independent interviewer with the Polish version of MINI-KID (version 2.0, 2001). There was higher agreement between clinical diagnoses and diagnoses based on MINI-KID interview with respect to eating disorders and externalizing disorders (κ 0.43-0.56) and lower in internalizing disorders (κ 0.13-0.45). In the clinical interview, there was smaller number of diagnostic categories (maximum 3 diagnoses per one patient) in comparison to MINI-KID (maximum 10 diagnoses per one patient), and the smaller percentage of patients with one diagnosis (65,7%) in comparison to MINI-KID interview (72%). Our study has shown satisfactory validity parameters of MINI-KID questionnaire, promoting its use for clinical and epidemiological settings. The Mini International Neuropsychiatry Interview for Children and Adolescent (MINI-KID) is the first structuralized diagnostic interview for assessing mental status in children and adolescents, which has been translated into Polish language. Our validation study demonstrated satisfactory psychometric properties of the questionnaire, enabling its use in clinical practice and in research projects. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Mini-Sniffer on Lakebed

    Science.gov (United States)

    1974-01-01

    The original Mini-Sniffer on Rogers Dry Lake, adjacent to NASA's Flight Research Center, Edwards AFB. This version of the remotely-piloted vehicle had swept-back wings, tip rudders, nose canards, and an air breathing engine. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  6. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  7. Force modeling for incisions into various tissues with MRF haptic master

    Science.gov (United States)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-03-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain.

  8. Force modeling for incisions into various tissues with MRF haptic master

    International Nuclear Information System (INIS)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-01-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain. (paper)

  9. Single incision laparoscopic pancreas resection for pancreatic metastasis of renal cell carcinoma.

    Science.gov (United States)

    Barbaros, Umut; Sümer, Aziz; Demirel, Tugrul; Karakullukçu, Nazlı; Batman, Burçin; Içscan, Yalın; Sarıçam, Gülay; Serin, Kürçsat; Loh, Wei-Liang; Dinççağ, Ahmet; Mercan, Selçuk

    2010-01-01

    Transumbilical single incision laparoscopic surgery (SILS) offers excellent cosmetic results and may be associated with decreased postoperative pain, reduced need for analgesia, and thus accelerated recovery. Herein, we report the first transumbilical single incision laparoscopic pancreatectomy case in a patient who had renal cell cancer metastasis on her pancreatic corpus and tail. A 59-year-old female who had metastatic lesions on her pancreas underwent laparoscopic subtotal pancreatectomy through a 2-cm umbilical incision. Single incision pancreatectomy was performed with a special port (SILS port) and articulated equipment. The procedure lasted 330 minutes. Estimated blood loss was 100mL. No perioperative complications occurred. The patient was discharged on the seventh postoperative day with a low-volume (20mL/day) pancreatic fistula that ceased spontaneously. Pathology result of the specimen was renal cell cancer metastases. This is the first reported SILS pancreatectomy case, demonstrating that even advanced surgical procedures can be performed using the SILS technique in well-experienced centers. Transumbilical single incision laparoscopic pancreatectomy is feasible and can be performed safely in experienced centers. SILS may improve cosmetic results and allow accelerated recovery for patients even with malignancy requiring advanced laparoscopic interventions.

  10. The Individual Features Of Indonesian-Chinese Mini-Novels

    Directory of Open Access Journals (Sweden)

    Ma Feng

    2011-11-01

    Full Text Available This article talks about mini-novels in the new period of Indonesian Chinese Literature. Through the overall developing trend of mini-novels’ corpuses, analyzes the individual creative features: firstly, the humor of Mo Mingmiao’s Mini-novels; secondly, the compassion of Xiao Xing’s Mini-novels; thirdly, Yuan Ni’s emotional sonata of The Lost Key-ring. By combination of themes and techniques of the three mini-novels corpuses, the article focuses on the analysis of three writers’ distinctive writing style.

  11. Mini-Sniffer II in Flight

    Science.gov (United States)

    1976-01-01

    This photograph shows the second Mini-Sniffer undergoing flight testing over Rogers Dry Lake in Edwards, California. This version of the Mini-Sniffer lacked the canard of the original version and had wing tips and tail booms added. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  12. Manual small incision extracapsular cataract surgery in Australia.

    Science.gov (United States)

    van Zyl, Lourens; Kahawita, Shyalle; Goggin, Michael

    2014-11-01

    Examination of the results and describing the technique of manual small incision extracapsular cataract extraction on patients with advanced cataracts in urban Australia. A descriptive case series. Thirty-eight patients at three public hospitals, one tertiary and two secondary ophthalmic units in urban Australia. Forty eyes with dense mature cataracts with hand movement vision or worse underwent a planned manual small incision extracapsular cataract extraction instead of traditional phaco-emulsification. Postoperative visual aquity, surgically induced astigmatism and complications. Seventy-eight per cent of patients had an uncorrected visual acuity of 6/12 or better on the first postoperative day. Eighty-three per cent of patients had a distance corrected visual acuity of 6/9 or better 3 months postoperatively. One case was complicated by a posterior capsule rupture. No cases of endophthalmitis were reported. The summated vector mean of the surgically induced astigmatism was 0.089D at 93°. Manual small incision extracapsular cataract extraction is an efficacious cataract surgery technique with good visual outcome and is a safe alternative to phaco-emulsification in suitable cases in a first-world setting. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  13. Current Status of the MiniBooNE Experiment

    OpenAIRE

    Ray, H.; collaboration, for the MiniBooNE

    2004-01-01

    MiniBooNE is an experiment designed to refute or confirm the LSND anti-nu_mu -> anti-nu_e oscillation result. MiniBooNE will look for oscillations of nu_mu -> nu_e in a closed-box appearance analysis. MiniBooNE began collecting data in 2002, and is expected to continue data taking through 2005. Current MiniBooNE results are presented.

  14. Surgically induced astigmatism after 3.0 mm temporal and nasal clear corneal incisions in bilateral cataract surgery

    Directory of Open Access Journals (Sweden)

    Je Hwan Yoon

    2013-01-01

    Full Text Available Aims: To compare the corneal refractive changes induced after 3.0 mm temporal and nasal corneal incisions in bilateral cataract surgery. Materials and Methods: This prospective study comprised a consecutive case series of 60 eyes from 30 patients with bilateral phacoemulsification that were implanted with a 6.0 mm foldable intraocular lens through a 3.0 mm horizontal clear corneal incision (temporal in the right eyes, nasal in the left eyes. The outcome measures were surgically induced astigmatism (SIA and uncorrected visual acuity (UCVA 1 and 3 months, post-operatively. Results: At 1 month, the mean SIA was 0.81 diopter (D for the temporal incisions and 0.92 D for nasal incisions (P = 0.139. At 3 months, the mean SIA were 0.53 D for temporal incisions and 0.62 D for nasal incisions (P = 0.309. The UCVA was similar in the 2 incision groups before surgery, and at 1 and 3 months post-operatively. Conclusion: After bilateral cataract surgery using 3.0 mm temporal and nasal horizontal corneal incisions, the induced corneal astigmatic change was similar in both incision groups. Especially in Asian eyes, both temporal and nasal incisions (3.0 mm or less would be favorable for astigmatism-neutral cataract surgery.

  15. Aorta-atria-septum combined incision for aortic valve re-replacement

    Science.gov (United States)

    Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong

    2018-01-01

    This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170

  16. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United States); Burman, Kari [National Renewable Energy Lab. (NREL), Golden, CO (United States); Singh, Mohit [National Renewable Energy Lab. (NREL), Golden, CO (United States); Esterly, Sean [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mutiso, Rose [US Department of Energy, Washington, DC (United States); McGregor, Caroline [US Department of Energy, Washington, DC (United States)

    2016-11-01

    Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that

  17. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  18. Minimal incision surgery in strabismus: Modified fornix-based approach.

    Science.gov (United States)

    Pérez-Flores, I

    2016-07-01

    To evaluate the modified fornix-based technique as an approach for minimal incision surgery in strabismus. The medical records of all consecutive patients that underwent strabismus surgery with fornix-based conjunctival incision between 2007 and 2012 were retrospectively reviewed. As a primary variable, an analysis was made of the wound size depending on the number of stitches. A descriptive study was performed on the variables related to patients and to the type of strabismus and surgery. Out of 153patients identified, 138 with 294 surgeries were included. In 200 (68%) interventions, the incision was sutured with one stitch, in 77 (26.2%) with 2, in 13 (4.4%) with 3, and in 4 (1.4%) with 4, with the mean number of stitches being 1.39±0.64. The mean age of the patients was 39years (2-80), and 36 (26.1%) had previous strabismus surgery, with topical anaesthesia being used in 35 (25.4%) cases. At 3months after surgery deviation was ≤10DP in 114 (82.6%) patients. There were no wound-related complications. The modified fornix-based technique is an effective and safe approach for minimal incision surgery in strabismus, in patients at all ages, with previous history of strabismus surgery and with topical anaesthesia. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  19. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  20. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users.

    Science.gov (United States)

    Albanese, John; Dugue, Geoffrey; Parvu, Valentin; Bajart, Ann M; Lee, Edwin

    2009-12-21

    Previous research has suggested that the silicon BD Atomic Edge knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence). The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  1. Medium-term results of Mini-arc for urinary stress incontinence in ambulatory patients under local anesthesia

    Directory of Open Access Journals (Sweden)

    Almog Levi

    Full Text Available Abstract Objective To evaluate the medium-term outcome and patient's satisfaction after Single-incision mini-sling (SIMS procedure done under local anesthesia in ambulatory set up for patients with stress urinary incontinence (SUI. Materials and Methods This is a retrospective cohort study, including all patients submitted to SIMS procedure for SUI with MiniArc (AMS, U.S.A without concomitant surgery between January 2011 and March 2013. Patients were followed up during 12 months after surgery and once a year subsequently. Telephone interviews were conducted to evaluate patient satisfaction. Outcome masseurs included: SUI cure rate, urinary urge incontinence (UUI cure rate in patients with mixed urinary incontinence (MUI, intra and post-operative complications and patient satisfaction. Results Ninety-three patients were included with mean follow-up of 23 months. Fifty percent had MUI with predominant SUI. The cure rates of SUI (objective and subjective were 89%. UUI was cured in 40% of patients. No major complications occur, neither voiding obstruction or groin pain. Telephone interviews conducted after 26 months on average revealed high satisfaction rate from the procedure (8.8 out of 10 and from the local anesthesia. Visual analog scale (VAS rating was low during and after the procedure (2.38 and 2.69 respectively. Conclusions The SIMS procedure is safe and highly effective for SUI and it can be performed successfully under local anesthesia in an ambulatory setup.

  2. Standardization of the Korean version of Mini-Mental Adjustment to Cancer (K-Mini-MAC) scale: factor structure, reliability and validity.

    Science.gov (United States)

    Kang, Jee In; Chung, Hyun Cheol; Kim, Se Joo; Choi, Hye Jin; Ahn, Joong Bae; Jeung, Hei-Cheul; Namkoong, Kee

    2008-06-01

    Mental adjustment and coping affect the physical outcome and survival as well as quality of life in cancer patients. The Mini-Mental Adjustment to Cancer (Mini-MAC) scale is a new refined, economical and reliable self-rating instrument measuring cognitive and behavioral responses to cancer. The aim of this study was to evaluate the psychometric properties of the Mini-MAC in Korean cancer patients. A total of 208 cancer patients recruited from the Yonsei Cancer Center were assessed with the Mini-MAC and the Hospital Anxiety and Depression Scale (HADS). Principal component analysis with varimax rotation for the Korean version of Mini-MAC (K-Mini-MAC) confirmed four factors. Three had psychometric properties similar to Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) of the original Mini-MAC. A novel factor, named Positive Attitude, included items of both Fatalism (FA) and Fighting Spirit (FS) from the original version. The five subscales from the original version (AP, HH, FS, FA and CA) and Positive Attitude had acceptable internal reliabilities in our sample (Cronbach's alpha coefficient 0.50-0.86; correlation coefficient of test-retest 0.68-0.88). For the validity, significant interscale correlation was observed in the original five subscales and Positive Attitude. Each subscale including Positive Attitude was also significantly related to Depression and Anxiety of HADS. As a whole, the K-Mini-MAC was a reliable, valid and acceptable tool for Korean cancer patients. These findings can provide information about the cross-cultural validity of Mini-MAC scale's factor structure. Cultural differences were also discussed.

  3. Climate-sensitive feedbacks between hillslope processes and fluvial erosion in sediment-driven incision models

    Science.gov (United States)

    Skov, Daniel S.; Egholm, David L.

    2016-04-01

    Surface erosion and sediment production seem to have accelerated globally as climate cooled in the Late Cenozoic, [Molnar, P. 2004, Herman et al 2013]. Glaciers emerged in many high mountain ranges during the Quaternary, and glaciation therefore represents a likely explanation for faster erosion in such places. Still, observations and measurements point to increases in erosion rates also in landscapes where erosion is driven mainly by fluvial processes [Lease and Ehlers (2013), Reusser (2004)]. Flume experiments and fieldwork have shown that rates of incision are to a large degree controlled by the sediment load of streams [e.g. Sklar and Dietrich (2001), Beer and Turowski (2015)]. This realization led to the formulation of sediment-flux dependent incision models [Sklar and Dietrich (2004)]. The sediment-flux dependence links incision in the channels to hillslope processes that supply sediment to the channels. The rates of weathering and soil transport on the hillslopes are processes that are likely to respond to changing temperatures, e.g. because of vegetation changes or the occurrence of frost. In this study, we perform computational landscape evolution experiments, where the coupling between fluvial incision and hillslope processes is accounted for by coupling a sediment-flux-dependent model for fluvial incision to a climate-dependent model for weathering and hillslope sediment transport. The computational experiments first of all demonstrate a strong positive feedback between channel and hillslope processes. In general, faster weathering leads to higher rates of channel incision, which further increases the weathering rates, mainly because of hillslope steepening. Slower weathering leads to the opposite result. The experiments also demonstrate, however, that the feedbacks vary significantly between different parts of a drainage network. For example, increasing hillslope sediment production may accelerate incision in the upper parts of the catchment, while at

  4. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture

    Directory of Open Access Journals (Sweden)

    Inoue M

    2014-11-01

    Full Text Available Makoto Inoue,1 Dina Joy K Abulon,2 Akito Hirakata1 1Kyorin Eye Center, School of Medicine, Kyorin University, Tokyo, Japan; 2Alcon Research, Ltd., Irvine, CA, USA Purpose: To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture.Methods: We tested one ridged microvitreoretinal (MVR, one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type. Each blade’s straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design after simulated vitrectomy.Results: Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened “M-shaped” with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems.Conclusion: Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades. Keywords: entry system, incision closure, leakage, pars plana incision, sclerotomy, trocar blade 

  5. Influence of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients

    Directory of Open Access Journals (Sweden)

    Zhao-Rong Zeng

    2014-05-01

    Full Text Available AIM: To compare the effect of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients. METHODS: The cataract patients were selected in our hospital. The patients were divided into control group(corneal limbus opposite curved scleral tunnel incision groupand observation group(above the top of cornea or temporal transparent corneal incision grouprandomly. At 1wk; 1 and 3mo after surgery, the change of corneal astigmatism and vision of the patients in two groups were compared and analyzed. RESULTS:Compared with control group, 1wk; 1 and 3mo after surgery, the average corneal astigmatism and surgically induced corneal astigmatism of the patients in observation group were decreased significantly. The visual acuity and corrected visual acuity were increased significantly. There was statistically significant(PPCONCLUSION: Center distance and small incision corneal phacoemulsification can reduce postoperative astigmatism and improve postoperative visual acuity for cataract patients. It provides guarantee for further strengthen the clinical treated effect for cataract patients.

  6. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  7. What can we learn from fluvial incision in high mountains?

    Science.gov (United States)

    Fuchs, Margret; Gloaguen, Richard; Krbetschek, Matthias

    2013-04-01

    High and actively deforming mountain ranges attract the attention of geoscientists as they provide natural laboratories of fast evolving process-response systems. Tectonic compressional settings, often linked to perpendicular extension, control the topographic growth and hence, erosion, transport pathways and sedimentation. High altitude differences within short horizontal distances promote material re-organisation and high rates of surface processes. Furthermore, high mountains constitute orographic barriers that affect atmospheric circulations as well as host different climate regimes similar to those of widely separated latitudinal belts. Both cause a high sensitivity of surface processes to changes in climatic conditions. However, feedbacks between climatic and tectonic forcing are complex. Additionally, the dominance of one or the other varies in space and also over time, inheriting various traces of the paleo-morphodynamic conditions to the subsequent process regimes. To unravel the forces driving the evolution of relief in active mountains, numerous studies employ the drainage network of the corresponding mountains as a proxy of landscape evolution. Especially the rates of river incision provide a powerful tool to characterize the surface response and infer causes behind it. Several parameters of river incision are available to describe the fluvial incision at individual sites (e.g. terrace incision rates), along the river course (e.g. longitudinal river profiles, Hack index) and in its perpendicular dimension (e.g. valley cross sections, valley shape ratios). But they require careful interpretation. They are sensitive to both, climatic and tectonic forcing. Therefore, the synopsis of such indices for fluvial incision is essential to evaluate the role of climatic versus tectonic forcing. Here, we use the Panj river system, the major river draining the Pamir mountains of Central Asia, as an example. The Panj experiences high altitude changes of more than 4000

  8. A Precise 6 Ma Start Date for Fluvial Incision of the Northeastern Colorado Plateau Canyonlands

    Science.gov (United States)

    Thomson, S. N.; Soreghan, G. S.; Reiners, P. W.; Peyton, S. L.; Murray, K. E.

    2015-12-01

    Outstanding questions regarding late Cenozoic Colorado Plateau landscape evolution include: (1) the relative roles of isostatic rebound as result Colorado River incision versus longer-term geodynamic processes in driving overall rock uplift of the plateau; and (2) whether incision was triggered by river integration or by a change in deep-seated mantle lithosphere dynamics. A key to answering these questions is to date more precisely the onset of incision to refine previous estimates of between 6 and 10 Ma. We present new low-temperature thermochronologic results from bedrock and deep borehole samples in the northeastern Colorado Plateau to show that rapid river incision began here at 6 Ma (5.93±0.66 Ma) with incision rates increasing from 15-50 m/Myr to 160-200 m/Myr. The onset time is constrained independently by both inverse time-temperature modeling and by the break-in-slope in fission track age-elevation relationships. This new time constraint has several important implications. First, the coincidence in time with 5.97-5.3 Ma integration of the lower Colorado River through the Grand Canyon to the Gulf of California strongly favors downstream river integration triggering carving of the canyonlands of the upper Colorado River system. Second, it implies integration of the entire Colorado River system in less than 2 million years. Third, rock uplift of the plateau driven by the flexural isostatic response to river incision is restricted to just the last 6 Ma, as is associated increased sediment budget. Fourth, incision starting at 6 Ma means that previous estimates of upper Colorado River incision rates based on 10-12 Ma basalt datum levels are too low. This also changes the dependency of measured time interval on incision rate from a non-steady-state negative power-law dependence (exponent of -0.24) to a near steady-state dependence (exponent of 0.07) meaning that long-term upper Colorado river incision rates can provide a reliable proxy for rock uplift rates.

  9. Kualitas Pengeringan Kayu Mahoni pada Berbagai Variasi Kerapatan Incising dengan Dua Skedul Pengeringan Suhu tinggi

    Directory of Open Access Journals (Sweden)

    Tomy Listyanto

    2016-11-01

    Full Text Available Tujuan dari penelitian ini adalah untuk mengetahui pengaruh interaksi variasi kerapatan incising dan dua skedul pengeringan terhadap kecepatan dan cacat-cacat pengeringan kayu mahoni, serta mengetahui pengaruh variasi kerapatan incising terhadap kekuatan lengkung statik kayu mahoni yang telah dikeringkan. Tiga pohon mahoni (Swietenia mahagony berdiameter 300-350 mm ditebang dan selanjutnya dibelah dan dibuat menjadi balok dengan ukuran 60 mm × 100 mm dengan panjang 500 mm untuk dijadikan sampel pengeringan. Di antara masing-masing bagian tersebut, dibuat sampel ukuran 20 mm × 20 mm × 25 mm, yang digunakan untuk penentu kadar air awal dan distribusinya. Sampel pengeringan selanjutnya dibagi menjadi 5 variasi kerapatan incising, yaitu 0 lubang/m2 (tanpa incising, 1000 lubang/m2, 2000 lubang/m2, 3000 lubang/m2, dan 4000 lubang/m2. Setiap variasi kerapatan incising selanjutnya akan dikeringkan dengan 2 skedul pengeringan, yaitu suhu pengeringan 100°C sampai tercapai kadar air akhir 12% dan suhu 60°C pada 8 jam pertama dan selanjutnya dilanjutkan 100°C, sampai tercapai kadar air akhir 12%. Paramater yang diamati adalah kecepatan pengeringan, cacat retak permukaan, dan distribusi kadar air akhir. Hasil analisis menunjukkan bahwa kerapatan incising 3000-4000 lubang/m2 memberikan pengaruh yang cukup nyata di dalam mempercepat proses pengeringan dan distribusi kadar air akhir. Skedul pengeringan dan variasi kerapatan incising tidak berpengaruh pada retak permukaan. Pra perlakuan incising sampai batas 4000 lubang/m2 ini dapat diterapkan untuk mempercepat proses pengeringan dengan penurunan nilai modulus elastisitas dan modulus patah yang tidak berbeda nyata. Kata kunci: incising, pengeringan suhu tinggi, mahoni, lengkung statik, skedul pengeringan   Drying Quality of Mahoni Wood in Various Incising Densities and Two High Temperature-Drying Schedules Abstract The aims of this research were to investigate the effects of interaction

  10. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  11. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    Directory of Open Access Journals (Sweden)

    Parvu Valentin

    2009-12-01

    Full Text Available Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Methods Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. Results The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence. The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value Conclusions For experienced users, the silicon accurate depth knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  12. Simulation of channel sandstone architecture in an incised valley

    Energy Technology Data Exchange (ETDEWEB)

    Frykman, P.; Johannessen, P.; Andsbjerg, J.

    1998-12-31

    The present report describes a geostatistical modelling study that is aimed at reflecting the architecture of the channel sandstones in an incised valley fill. The example used for this study is a part of the Middle Jurassic sandy succession of the Bryne Formation in the Danish central Graben. The succession consists mainly of fluvial sediments in the lower part, overlain by tidal influenced sediments, which again is overlain by shallow marine sediments. The modelling study has been performed on a sequence of incised valley sediments in the upper part of the Bryne Formation overlying fluvial sediments. (au) EFP-96. 19 refs.

  13. Uptake of gallium-67 citrate in clean surgical incisions after colorectal surgery

    International Nuclear Information System (INIS)

    Lin Wanyu; Wang Shyhjen; Tsai Shihchuan; Chao Tehsin

    2001-01-01

    Non-specific accumulation of gallium-67 citrate (gallium) in uncomplicated surgical incisions is not uncommon. It is important to know the normal pattern of gallium uptake at surgical incision sites in order to properly interpret the gallium scan when investigating possible wound infection in patients who have undergone abdominal surgery. We studied 42 patients without wound infection after colorectal surgery and performed gallium scans within 40 days after surgery. Patients were divided into three groups according to the interval between the operation and the scan. In group A (26 patients) gallium scan was performed within 7 days after surgery, in group B (8 patients) between 8 and 14 days after surgery, and in group C (8 patients) between 15 and 40 days after surgery. Our data showed that in group A, 61.5% had gallium accumulation at the surgical incision site. In group B, 50% had accumulation of gallium at the surgical incision site, while in group C only one patient (12.5%) showed gallium uptake. It is concluded that the incidence of increased gallium uptake at clean surgical incision sites is high after colorectal surgery. Nuclear medicine physicians should bear in mind the high incidence of non-specific gallium uptake at such sites during the interpretation of possible wound infection in patients after colorectal surgery. (orig.)

  14. Single-incision laparoscopic surgery through an ostomy site: a natural approach by an unnatural orifice.

    Science.gov (United States)

    Lopez, Nicole E; Peterson, Carrie Y; Ramamoorthy, Sonia L; McLemore, Elisabeth C; Sedrak, Michael F; Lowy, Andrew M; Horgan, Santiago; Talamini, Mark A; Sicklick, Jason K

    2015-02-01

    Single-incision laparoscopic surgery (SILS) is gaining popularity for a wide variety of surgical operations and capitalizes on the benefits of traditional laparoscopic surgery without incurring multiple incision sites. Traditionally, SILS is performed by a midline periumbilical approach. However, such a minimally invasive approach may be utilized in patients who already have an abdominal incision. Our series retrospectively reviews 7 cases in which we utilized the fascial defect at the time of after ostomy reversal as our SILS incision site. In turn, we performed a variety of concurrent intra-abdominal procedures with excellent technical success and outcomes. Our study is the largest single-institution case series of this novel approach and suggests that utilizing an existing ostomy-site abdominal incision is a safe and effective location for SILS port placement and should be considered in patients undergoing concurrent procedures.

  15. Steady incision of Grand Canyon at the million year timeframe: a case for mantle-driven differential uplift

    Science.gov (United States)

    Crow, Ryan S.; Karl Karlstrom,; Laura Crossey,; Richard Young,; Michael Ort,; Yemane Asmerom,; Victor Polyak,; Andrew Darling,

    2014-01-01

    The Grand Canyon region provides an excellent laboratory to examine the interplay between river incision, magmatism, and the geomorphic and tectonic processes that shape landscapes. Here we apply U-series, Ar–Ar, and cosmogenic burial dating of river terraces to examine spatial variations in incision rates along the 445 km length of the Colorado River through Grand Canyon. We also analyze strath terrace sequences that extend to heights of several hundred meters above the river, and integrate these with speleothem constrained maximum incision rates in several reaches to examine any temporal incision variations at the million-year time frame. This new high-resolution geochronology shows temporally steady long-term incision in any given reach of Grand Canyon but significant variations along its length from 160 m/Ma in the east to 101 m/Ma in the west. Spatial and temporal patterns of incision, and the long timescale of steady incision rule out models where geomorphic controls such as climate oscillations, bedrock strength, sediment load effects, or isostatic response to differential denudation are the first order drivers of canyon incision. The incision pattern is best explained by a model of Neogene and ongoing epeirogenic uplift due to an eastward propagating zone of increased upper mantle buoyancy that we infer from propagation of Neogene basaltic volcanism and a strong lateral gradient in modern upper mantle seismic structure.

  16. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    Science.gov (United States)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  17. MINI-THESAURUS, Energy Data Base Subject Thesaurus Generator

    International Nuclear Information System (INIS)

    Paulk, J.W.

    2003-01-01

    1 - Description of program or function: MINI-THESAURUS allows the user to subset into highly-specialized 'mini-thesauri' the Energy Data Base (EDB) Subject Thesaurus, which contains the standard vocabulary of indexing terms (descriptors) developed and structured by the Office of Scientific and Technical Information (OSTI) for the building and maintenance of the U.S. Department of Energy (DOE) energy information databases. This structured vocabulary reflects the scope of DOE's research, development, and technological programs and encompasses terminology derived not only from the basic sciences but also from the areas of energy, conservation, safety, environmental impact, and regulation. Entire word blocks may be copied from the primary Subject Thesaurus, from another mini-thesaurus, or both, and subsequently modified through the addition of new terms, the deletion of existing terms, and changes to the internal relationships among the word blocks within the mini-thesaurus to create a new, special-purpose thesaurus. MINI-THESAURUS also provides the ability to copy the entire Subject Thesaurus and to treat the copy as a mini-thesaurus, thus allowing one to examine the effects of major changes to the thesaurus structure without having to modify the primary, on-line Thesaurus. The copy operation also optimizes the Subject Thesaurus structure. An interactive user having update privileges for a specific mini-thesaurus and access to the TeX and PostScript proprietary software can produce the mini-thesaurus in printed publication format. Once the mini-thesaurus has been published, periodic supplements may be generated based on date of entry or change maintained by the Thesaurus software. 2 Restrictions on the complexity of the problem: The system enforces the OSTI rules for Thesaurus development

  18. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  19. Spurious RF signals emitted by mini-UAVs

    Science.gov (United States)

    Schleijpen, Ric (H. M. A.); Voogt, Vincent; Zwamborn, Peter; van den Oever, Jaap

    2016-10-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to the sensor community. The detection, classification and identification chain can take advantage of different sensor technologies. Apart from the signatures used by radar and electro-optical sensor systems, the UAV also emits RF signals. These RF signatures can be split in intentional signals for communication with the operator and un-intentional RF signals emitted by the UAV. These unintentional or spurious RF emissions are very weak but could be used to discriminate potential UAV detections from false alarms. The goal of this research was to assess the potential of exploiting spurious emissions in the classification and identification chain of mini-UAVs. It was already known that spurious signals are very weak, but the focus was on the question whether the emission pattern could be correlated to the behaviour of the UAV. In this paper experimental examples of spurious RF emission for different types of mini-UAVs and their correlation with the electronic circuits in the UAVs will be shown

  20. Incision and stress regulation in borderline personality disorder: neurobiological mechanisms of self-injurious behaviour.

    Science.gov (United States)

    Reitz, Sarah; Kluetsch, Rosemarie; Niedtfeld, Inga; Knorz, Teresa; Lis, Stefanie; Paret, Christian; Kirsch, Peter; Meyer-Lindenberg, Andreas; Treede, Rolf-Detlef; Baumgärtner, Ulf; Bohus, Martin; Schmahl, Christian

    2015-08-01

    Patients with borderline personality disorder frequently show non-suicidal self-injury (NSSI). In these patients, NSSI often serves to reduce high levels of stress. Investigation of neurobiological mechanisms of NSSI in borderline personality disorder. In total, 21 women with borderline personality disorder and 17 healthy controls underwent a stress induction, followed by either an incision into the forearm or a sham treatment. Afterwards participants underwent resting-state functional magnetic resonance imaging while aversive tension, heart rate and heart rate variability were assessed. We found a significant influence of incision on subjective and objective stress levels with a stronger decrease of aversive tension in the borderline personality disorder group following incision than sham. Amygdala activity decreased more and functional connectivity with superior frontal gyrus normalised after incision in the borderline personality disorder group. Decreased stress levels and amygdala activity after incision support the assumption of an influence of NSSI on emotion regulation in individuals with borderline personality disorder and aids in understanding why these patients use self-inflicted pain to reduce inner tension. © The Royal College of Psychiatrists 2015.

  1. Mini-Sniffer III on Lakebed

    Science.gov (United States)

    1976-01-01

    The third remotely-piloted Mini-Sniffer research vehicle rests on the lakebed adjacent to the Dryden Flight Research Center, Edwards, California. This view shows the wing shape, hydrazine engine, and the tail booms. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  2. Feasibility of mini-tablets as a flexible drug delivery tool.

    Science.gov (United States)

    Mitra, Biplob; Chang, Jessica; Wu, Sy-Juen; Wolfe, Chad N; Ternik, Robert L; Gunter, Thomas Z; Victor, Michael C

    2017-06-15

    Mini-tablets have potential applications as a flexible drug delivery tool in addition to their generally perceived use as multi-particulates. That is, mini-tablets could provide flexibility in dose finding studies and/or allow for combination therapies in the clinic. Moreover, mini-tablets with well controlled quality attributes could be a prudent choice for administering solid dosage forms as a single unit or composite of multiple mini-tablets in patient populations with swallowing difficulties (e.g., pediatric and geriatric populations). This work demonstrated drug substance particle size and concentration ranges that achieve acceptable mini-tablet quality attributes for use as a single or composite dosage unit. Immediate release and orally disintegrating mini-tablet formulations with 30μm to 350μm (particle size d 90 ) acetaminophen and Compap™ L (90% acetaminophen) at concentrations equivalent to 6.7% and 26.7% acetaminophen were evaluated. Mini-tablets achieved acceptable weight variability, tensile strength, friability, and disintegration time at a reasonable solid fraction for each formulation. The content uniformity was acceptable for mini-tablets of 6.7% formulations with ≤170μm drug substance, mini-tablets of all 26.7% formulations, and composite dosage units containing five or more mini-tablets of any formulation. Results supported the manufacturing feasibility of quality mini-tablets, and their applicability as a flexible drug delivery tool. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Ultrasonographic evaluation of the healing of ventral midline abdominal incisions in the horse.

    Science.gov (United States)

    Wilson, D A; Badertscher, R R; Boero, M J; Baker, G J; Foreman, J H

    1989-06-01

    Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the progression of incisional complications in a non-invasive manner.

  4. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    International Nuclear Information System (INIS)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz; De Oliveira Santos, Christiano

    2016-01-01

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region

  5. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    Energy Technology Data Exchange (ETDEWEB)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); De Oliveira Santos, Christiano [Dept. of Stomatology, Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Sao Paulo (Brazil)

    2016-09-15

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region.

  6. Better outcome from arthroscopic partial meniscectomy than skin incisions only?

    DEFF Research Database (Denmark)

    Roos, Ewa M; Hare, Kristoffer Borbjerg; Nielsen, Sabrina Mai

    2018-01-01

    . In total, nine participants experienced 11 adverse events; six in the surgery group and three in the skin-incisions-only group. CONCLUSION: We found greater improvement from arthroscopic partial meniscectomy compared with skin incisions only at 2 years, with the statistical uncertainty of the between......-group difference including what could be considered clinically relevant. Because of the study being underpowered, nearly half in the sham group being non-blinded and one-third crossing over to surgery, the results cannot be generalised to the greater patient population. TRIAL REGISTRATION NUMBER: NCT01264991....

  7. The "Propeller" incision for transpalatal advancement pharyngoplasty: a new approach to reduce post-operative oronasal fistulae.

    Science.gov (United States)

    Shine, Neville Patrick; Lewis, Richard Hamilton

    2008-09-01

    To present a new soft tissue approach for transpalatal advancement pharyngoplasty (TPA), the propeller incision, and to compare the rates of post-operative oronasal fistula in those undergoing TPA with the traditional "Gothic Arch" incision described by Woodson and those with the propeller incision. A prospectively maintained adult sleep apnoea surgery database was used to identify those patients undergoing TPA, either alone or in combination with other procedures, for obstructive sleep apnoea syndrome (OSAS) between February 2001 and September 2006 in a tertiary referral centre by a single surgeon (RHL). In addition to the incision used during TPA, patient demographic data, previous surgery of the upper airways, smoking history, pre-operative body mass index, respiratory disturbance index, oxygen saturation index and the occurrence of oronasal fistula post-operatively, were recorded. The propeller incision technique is described. A total of 89 patients who underwent TPA were identified. A total of 49 patients had a "Gothic Arch" incision and 40 had a "Propeller" incision. The two groups of patients were comparable in age, sex, previous tonsillar and uvulopalatopharyngoplasty surgery, smoking histories and pre-operative disease severity. In the "Gothic Arch" group, eight patients (16%) developed oronasal fistulae in the post-operative period versus only one patient (2.5%) in the "Propeller" group. The difference between the two groups was statistically significant (P=0.038, Fisher's exact test). Of the total cases with post-operative oronasal fistula (n=9), only one patient (from the Gothic Arch incision group) required operative closure which was performed under local anesthesia and healed without complication. The propeller incision provides an anatomically sensible axial-based flap that provides adequate access to perform TPA. It is associated with a lower incidence of oronasal fistula and is recommended by the authors.

  8. Mini-marathon groups: psychological "first aid" following disasters.

    Science.gov (United States)

    Terr, L C

    1992-01-01

    Large group counseling sessions for soldiers following battle have been commonly used since World War II. The author conceptualizes and demonstrates how these mini-marathon sessions can be adapted to support all ages and types of civilians involved in disasters. Mini-marathons take about 3 hours and are divided into three sections: story sharing, symptom sharing, and suggestions for self-help, including sharing tales of heroism and survival. After an initial mini-marathon session, a second session may be held emphasizing creativity. The author also describes how mini-marathons can be adapted for therapists who will lead their own sessions.

  9. The use of mini-samples in palaeomagnetism

    Science.gov (United States)

    Böhnel, Harald; Michalk, Daniel; Nowaczyk, Norbert; Naranjo, Gildardo Gonzalez

    2009-10-01

    Rock cores of ~25 mm diameter are widely used in palaeomagnetism. Occasionally smaller diameters have been used as well which represents distinct advantages in terms of throughput, weight of equipment and core collections. How their orientation precision compares to 25 mm cores, however, has not been evaluated in detail before. Here we compare the site mean directions and their statistical parameters for 12 lava flows sampled with 25 mm cores (standard samples, typically 8 cores per site) and with 12 mm drill cores (mini-samples, typically 14 cores per site). The site-mean directions for both sample sizes appear to be indistinguishable in most cases. For the mini-samples, site dispersion parameters k on average are slightly lower than for the standard samples reflecting their larger orienting and measurement errors. Applying the Wilcoxon signed-rank test the probability that k or α95 have the same distribution for both sizes is acceptable only at the 17.4 or 66.3 per cent level, respectively. The larger mini-core numbers per site appears to outweigh the lower k values yielding also slightly smaller confidence limits α95. Further, both k and α95 are less variable for mini-samples than for standard size samples. This is interpreted also to result from the larger number of mini-samples per site, which better averages out the detrimental effect of undetected abnormal remanence directions. Sampling of volcanic rocks with mini-samples therefore does not present a disadvantage in terms of the overall obtainable uncertainty of site mean directions. Apart from this, mini-samples do present clear advantages during the field work, as about twice the number of drill cores can be recovered compared to 25 mm cores, and the sampled rock unit is then more widely covered, which reduces the contribution of natural random errors produced, for example, by fractures, cooling joints, and palaeofield inhomogeneities. Mini-samples may be processed faster in the laboratory, which is of

  10. Single-incision laparoscopic bariatric surgery

    Directory of Open Access Journals (Sweden)

    Huang Chih-Kun

    2011-01-01

    Full Text Available Background: Bariatric surgery has been established as the best option of treatment for morbid obesity. In recent years single-incision laparoscopic surgery (SILS has emerged as another modality of carrying out the bariatric procedures. While SILS represents an advance, its application in morbid obesity at present is limited. In this article, we review the technique and results of SILS in bariatric surgery. Methods: The PubMed database was searched and totally 11 series reporting SILS in bariatric surgery were identified and analyzed. The case reports were excluded. Since 2008, 114 morbidly obese patients receiving SILS bariatric surgeries were reported. Results: The procedures performed included SILS gastric banding, sleeve gastrectomy and gastric bypass. No mortality was reported in the literatures. Sixteen patients (14.05% needed an additional incision for a liver retractor, a trocar or for conversion. Only one complication of wound infection was reported in these series. All the surgeons reported that the patients were highly satisfied with the scar. Conclusion: Because of abundant visceral and subcutaneous fat and multiple comorbidities in morbid obesity, it is more challenging for surgeons to perform the procedures with SILS. It is clear that extensive development of new instruments and technical aspects of these procedures as well as randomized studies to compare them with traditional laparoscopy are essential before these procedures can be utilized in day-to-day clinical practice.

  11. Heat transfer and pressure drop characteristics of mini-fin structures

    International Nuclear Information System (INIS)

    Jiang Peixue; Xu Ruina

    2007-01-01

    Forced convection heat transfer of air and water in bronze and pure copper mini-fin structures and mini-channel structures was investigated experimentally. The mini-fin dimensions were 0.7 mm x 0.2 mm and 0.8 mm x 0.4 mm. The tests included both staggered diamond-shaped and in-line square mini-fin arrangements. The tests investigated the effects of structures, mini-fin dimensions and arrangement, test section materials, and fluid properties on the convection heat transfer and heat transfer enhancement. For the tested conditions, the convection heat transfer coefficient was increased 9-21 fold for water and 12-38 fold for air in the mini-fin structures compared with an empty plate channel. The friction factor and flow resistance in the mini-channel structures and the in-line square mini-fin arrangement were much less than in the staggered diamond-shaped mini-fin arrangement. For the small channel width, W c = 0.2 mm, the convection heat transfer with the in-line square array structure was more intense than with the staggered diamond-shaped structure, the mini-channel structure or the porous media. For the larger channel width, W c = 0.4 mm, the convection heat transfer in the staggered diamond-shaped array structure was more intense than in the others systems while the in-line square structure had the best overall thermal-hydraulic performance

  12. Treatment for incarcerated indirect hernia with "Cross-Internal Ring" inguinal oblique incision in children.

    Science.gov (United States)

    Yan, Xue-Qiang; Yang, Jun; Zheng, Nan-Nan; Kuang, Hou-Fang; Duan, Xu-Fei; Bian, Hong-Qiang

    2017-01-01

    This study aims to evaluate the utility of the "Cross-Internal Ring" inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH) complicated with severe abdominal distension. Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the "Cross-Internal Ring" inguinal oblique incision. There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6-18 months. No recurrence or iatrogenic cryptorchidism happened. "Cross-Internal Ring" inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  13. Transverse Skin Crease versus Vertical Midline Incision versus Laparoscopy for Right Hemicolectomy: A Systematic Review—Current Status of Right Hemicolectomy

    Directory of Open Access Journals (Sweden)

    Alberto Santoro

    2014-01-01

    Full Text Available Purpose. The right hemicolectomy may be conducted through laparoscopic or laparotomic surgery, transverse or midline incisions. The transverse laparotomy offers some advantages compared to the midline laparotomy and laparoscopy. A literature review was performed to evaluate the possible advantages of the transverse incision versus midline incision or laparoscopic right hemicolectomy. Methods. A systematic research was performed in Medline, Embase, Cochrane Central Register of Controlled Trials, CINAHL, BioMed Central, and the Science Citation Index. Results. Laparotomic right hemicolectomy with transverse incision is preferable to laparotomic hemicolectomy with midline incision. A transverse incision offers a lessened postoperative pain following physical activity, a lessened need to administer analgesic therapy during the post-operative time, better aesthetic results, and a better post-operative pulmonary function. Open surgery with transverse or midline incision ensured a shorter operative time, lower costs and a greater length of the incision compared to the laparoscopic. However, there are no differences in the oncological outcomes. Conclusions. It was not possible to identify significant differences between the open right hemicolectomy with transverse incision versus the open right hemicolectomy with midline incision or laparoscopic hemicolectomy.

  14. Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [ARIES Collaborative, New York, NY (United States); Podorson, David [ARIES Collaborative, New York, NY (United States); Varshney, Kapil [ARIES Collaborative, New York, NY (United States)

    2014-05-01

    Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

  15. Minimal Nasolabial Incision Technique for Nasolabial Fold Modification in Patients With Facial Paralysis.

    Science.gov (United States)

    Faris, Callum; Heiser, Alyssa; Jowett, Nate; Hadlock, Tessa

    2018-03-01

    Creation of symmetrical nasolabial folds (NLFs) is important in the management of the paralyzed face. Established techniques use a linear incision in the NLF, and technical refinements now allow the linear incision to be omitted. This retrospective case series was conducted in a tertiary care setting from February 2, 2017, to June 7, 2017. Participants were all patients (N = 21) with peripheral facial paralysis who underwent NLF modification that used the minimal nasolabial incision technique at the Massachusetts Eye and Ear Infirmary Facial Nerve Center from February 1, 2015, through August 31, 2016. Patient-reported outcome measures using the validated, quality-of-life Facial Clinimetric Evaluation (FaCE) Scale; clinician-reported facial function outcomes using a validated electronic clinician-graded facial paralysis assessment (eFACE); layperson assessment of the overall aesthetic outcome of the NLF; and expert-clinician scar assessment of the NLF. Of the 21 patients who underwent NLF modification that used the minimal nasolabial incision technique, 9 patients (43%) were female and 12 (57%) were male. The mean age was 41 (range, 9-90) years; 17 patients (81%) were adults (≥18 years) and 4 (19%) were children (<18 years). Overall, significant improvements were observed after NLF modification in all outcome measures as graded by both clinicians and patients. The mean (SD) scores for total eFACE were 60.7 (14.9) before the operation and 77.2 (8.9) after the operation (mean difference, 16.5 [95% CI, 8.5-24.2]; P < .001). The mean (SD) static eFACE scores were 61.4 (20.6) before the operation and 82.7 (12.4) after the operation (mean difference, 21.3 [95% CI, 10.7-31.9]; P < .001). The mean (SD) FaCE quality-of-life scores were 51.3 (20.1) before the operation and 70.3 (12.6) after the operation (mean difference, 19.0 [95% CI, 6.5-31.6]; P  =  .001). The layperson self-assessment of the overall aesthetic outcome of the NLF modification was

  16. Development of mini-LIA and primary experiments

    International Nuclear Information System (INIS)

    Cheng Cheng; Liao Shuqing; Zheng Shuxin; Lin Yuzheng; Tang Chuanxiang; Jing Xiaobing; Mu Fan; Pan Haifeng; Zhang Kaizhi; Shi Jinshui; Deng Jianjun

    2009-01-01

    Mini-LIA is a miniature of a linear induction accelerator developed by China Academy of Engineering Physics and Tsinghua University in 2007. It has been constructed with a thermionic cathode in an electron injector and a metglas core in the induction accelerator cavities. A double-pulsed electron beam was produced for the first time in China on the Mini-LIA with a thermionic cathode in the electron gun and a metglas core in the induction accelerator cavities. A double-pulsed beam current of more than 1.1A was obtained on condition of 80 kV double-pulsed high voltage produced by pulsed power system supplying to the injector and accelerating modules. Some primary experiments for measuring the parameters of Mini-LIA has been performed, and some beam characterizations of Mini-LIA are presented. Further improvement is underway. (authors)

  17. Mini lathe machine converted to CNC

    Directory of Open Access Journals (Sweden)

    Alexandru Morar

    2012-06-01

    Full Text Available This paper presents the adaptation of a mechanical mini-lathing machine to a computerized numerical control (CNC lathing machine. This machine is composed of a ASIST mini-lathe and a two-degrees-of-freedom XZ stage designed specifically for this application. The whole system is controlled from a PC using adequate CNC control software.

  18. Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis.

    Science.gov (United States)

    Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Elmaraezy, Ahmed; Menshawy, Amr; Menshawy, Esraa; Ismail, Mahmoud; Samir, Esraa; Khaled, Anas; Zakarya, Hagar; El-Tonoby, Abdelrahman; Ghanem, Esraa

    2017-12-01

    Although cutting electrocautery can be superior to the scalpel in reducing blood loss and incisional time, several reports associated electrocautery with higher rates of wound infection, impaired healing, and worse cosmesis. We performed this systematic review and meta-analysis to compare cutting electrocautery versus scalpel for surgical incisions. We conducted a computerized literature search of five electronic databases and included all published original studies comparing cutting electrocautery and scalpel surgical incisions. Relevant data were extracted from eligible studies and pooled as odds ratios (ORs) or standardized mean difference (SMD) values in a meta-analysis model, using RevMan and Comprehensive Meta-analysis software. Forty-one studies (36 randomized trials, four observational, and one quasirandom study) were included in the pooled analysis (6422 participants). Compared with the scalpel incision, cutting electrocautery resulted in significantly less blood loss (SMD = -1.16, 95% CI [-1.60 to -0.72]), shorter incisional (SMD = -0.63, 95% CI [-0.96 to -0.29]) and operative times (SMD = -0.59, 95% CI [-1.12 to -0.05]), and lower pain scores (SMD = -0.91, 95% CI [-1.27 to -0.55]) with no significant differences in terms of wound infection rates (OR = 0.92, 95% CI [0.74-1.15]) or overall subjective scar score (SMD = -0.49, 95% CI [-1.72 to 0.75]). Surgical incision using electrocautery can be quicker with less blood loss and postoperative pain scores than the scalpel incision. No statistically significant difference was found between both techniques in terms of postoperative wound complications, hospital stay duration, and wound cosmetic characteristics. Therefore, we recommend routine use of cutting electrocautery for surgical incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Detection of dementia in primary care: comparison of the original and a modified Mini-Cog Assessment with the Mini-Mental State Examination.

    Science.gov (United States)

    Kamenski, Gustav; Dorner, Thomas; Lawrence, Kitty; Psota, Georg; Rieder, Anita; Schwarz, Franz; Sepandj, Asita; Spiegel, Wolfgang; Strotzka, Stefan

    2009-12-01

    Background Dementia is considered widely under-detected in primary care, and general practitioners (GPs) frequently ask for easy to use tools to assist in its early detection.Aim To determine the degree of correlation between the Mini-Cog Assessment (Mini-Cog) as performed by GPs and the Mini-Mental State Examination (MMSE).Design of study This was a prospective study (2005, 2006) comparing two cognitive screening instruments.Setting Ten general practices in Austria, with patients with a hitherto undiagnosed suspicion of dementia seen consecutively.Method Sensitivity, specificity and positive and negative predictive values (PPVs and NPVs) of the Mini-Cog (applying both a colour-coded and the original rating method) were assessed for degree of correlation with the MMSE. In phase one GPs examined patients suspected of having dementia using the Mini-Cog; in phase two a neurologist retested them applying the MMSE, a clock-drawing test (CDT) and a routine clinical examination. A questionnaire on the practicability of the Mini-Cog was answered by GPs.Results Of the 107 patients who participated 86 completed the whole study protocol. The Mini-Cog, as performed by the ten GPs, displayed a sensitivity of 0.85 (95% CI: 0.71, 0.98), a specificity of 0.58 (95% CI: 0.46, 0.71), a PPV of 0.47 (95% CI: 0.33, 0.61) and an NPV of 0.90 (95% CI: 0.80, 0.99) as against the MMSE carried out by neurologists. The GPs judged the Mini-Cog useful and time saving.Conclusion The Mini-Cog has a high sensitivity and acceptable specificity in the general practice setting and has proved to be a practicable tool for the diagnosis of dementia in primary care.

  20. TVT-Secur mini-sling for stress urinary incontinence: a review of outcomes at 12 months.

    Science.gov (United States)

    Walsh, Colin A

    2011-09-01

    • Synthetic mid-urethral slings (MUSs) are considered the first choice surgical procedure for stress urinary incontinence. Recent publications have raised concerns about the efficacy of third generation single-incision mini-slings. The present paper is a systematic review of studies reporting 12-month outcomes after the TVT-Secur (TVT-S) procedure. • Pubmed/Medline online databases, abstracts from recent International Continence Society and International Urogynecological Association annual scientific meetings and the Clinicaltrials.gov and Controlled-trials.com online trial registries were searched for English-language articles containing the terms 'TVT-Secur', 'TVT Secur' or 'mini-sling'. The primary outcomes were objective and subjective cure rates at 12 months. Secondary outcomes included peri-operative (vaginal perforation, urinary retention, urinary tract infection [UTI]) and postoperative (mesh exposure, de novo overactive bladder (OAB), dyspareunia and return to theatre) complication rates. • Among 1178 women undergoing the TVT-S procedure, from 10 studies, both objective and subjective cure rate at 12 months was 76%, with objective cure significantly higher in women undergoing the 'U-type' approach. Vaginal perforation was a complication in 1.5% of cases, with a 2.4% incidence of mesh exposure in the first year. The incidence of de novo OAB symptoms was 10%. Rates of urinary retention (2.3%), UTI (4.4%), dyspareunia (1%) and return to theatre for complications (0.8%) were low. In the first year after a TVT-S procedure 5% of women required repeat continence surgery. • Longer-term studies and randomized comparisons with more established MUSs are required before TVT-S should be routinely used in the surgical treatment of stress urinary incontinence. © 2011 THE AUTHOR. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  1. DNA polymerase. beta. reaction with ultraviolet-irradiated DNA incised by correndonuclease

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, R; Zarebska, Z [Instytut Onkologii, Warsaw (Poland); Zmudzka, B [Polska Akademia Nauk, Warsaw. Inst. Biochemii i Biofizyki

    1980-09-19

    Covalently closed circular Col E1 DNA was ultraviolet-irradiated with a dose of 60 J/m/sup 2/, thus introducing about 3.2 pyrimidine dimers per DNA molecule. Treatment of irradiated Col E1 DNA with Micrococcus luteus correndonuclease resulted, in the vicinity of pyrimidine dimers, in an average of 3.3 incisions per DNA molecule, and converted DNA to the open circular form. Incised Col E1 DNA stimulated no reaction with calf thymus DNA polymerase ..cap alpha.. but was recognized as a template by DNA polymerase ..beta... The latter enzyme incorporated about 1.6 molecules of dTMP (corresponding to 6 molecules of dNMP) per one correndonuclease incision. The length of the DNA polymerase ..beta.. product was comparable to the anticipated length of the DNA region within which the hydrogen bonds were disrupted owing to dimer formation. The enzyme required Mg/sup 2 +/ and four dNTPs for reaction and was resistant to N-ethylmaleimide or p-mercuribenzoate.

  2. Human FAN1 promotes strand incision in 5'-flapped DNA complexed with RPA.

    Science.gov (United States)

    Takahashi, Daisuke; Sato, Koichi; Hirayama, Emiko; Takata, Minoru; Kurumizaka, Hitoshi

    2015-09-01

    Fanconi anaemia (FA) is a human infantile recessive disorder. Seventeen FA causal proteins cooperatively function in the DNA interstrand crosslink (ICL) repair pathway. Dual DNA strand incisions around the crosslink are critical steps in ICL repair. FA-associated nuclease 1 (FAN1) is a DNA structure-specific endonuclease that is considered to be involved in DNA incision at the stalled replication fork. Replication protein A (RPA) rapidly assembles on the single-stranded DNA region of the stalled fork. However, the effect of RPA on the FAN1-mediated DNA incision has not been determined. In this study, we purified human FAN1, as a bacterially expressed recombinant protein. FAN1 exhibited robust endonuclease activity with 5'-flapped DNA, which is formed at the stalled replication fork. We found that FAN1 efficiently promoted DNA incision at the proper site of RPA-coated 5'-flapped DNA. Therefore, FAN1 possesses the ability to promote the ICL repair of 5'-flapped DNA covered by RPA. © The Authors 2015. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  3. Femtosecond laser effect on the self-sealing properties of the corneal incision of various lengths and profile (experimental trial

    Directory of Open Access Journals (Sweden)

    Yulduz Shavkatovna Nizametdinova

    2015-06-01

    Full Text Available An experimental investigation was carried out to study self-sealing properties of corneal incisions of different profile and length carried out with femtosecond laser Victus (Technolas Perfect Vision/Bausch&Lomb. Using femtosecond laser for this purpose allows creating corneal incisions of high precision and predictability. Reproducibility and standardization of the incision profile and length are an advantage of this technology. Obtained results showed that single-profile incisions are less stable and safe when compared to multi-profile ones. It was noted that incision length increase promotes its self-sealing properties.

  4. Prospects for Antineutrino Running at MiniBooNE

    OpenAIRE

    Wascko, M. O.

    2006-01-01

    MiniBooNE began running in antineutrino mode on 19 January, 2006. We describe the sensitivity of MiniBooNE to LSND-like nuebar oscillations and outline a program of antineutrino cross-section measurements necessary for the next generation of neutrino oscillation experiments. We describe three independent methods of constraining wrong-sign (neutrino) backgrounds in an antineutrino beam, and their application to the MiniBooNE antineutrino analyses.

  5. A mini-UAV VTOL Platform for Surveying Applications

    Directory of Open Access Journals (Sweden)

    Kuldeep Rawat

    2014-05-01

    Full Text Available In this paper we discuss implementation of a mini-Unmanned Aerial Vehicle (UAV vertical take-off and landing (VTOL platform for surveying activities related to highway construction. Recent advances in sensor and communication technologies have allowed scaling sizes of unmanned aerial platforms, and explore them for tasks that are economical and safe over populated or inhabited areas. In highway construction the capability of mini-UAVs to survey in hostile and/or hardly accessible areas can greatly reduce human risks. The project focused on developing a cost effective, remotely controlled, fuel powered mini-UAV VTOL (helicopter platform with certain payload capacity and configuration and demonstrated its use in surveying and monitoring activities required for highway planning and construction. With an on-board flight recorder global positioning system (GPS device, memory storage card, telemetry, inertial navigation sensors, and a video camera the mini-UAV can record flying coordinates and relay live video images to a remote ground receiver and surveyor. After all necessary integration and flight tests were done the mini-UAV helicopter was tested to operate and relay video from the areas where construction was underway. The mini-UAV can provide a platform for a range of sensors and instruments that directly support the operational requirements of transportation sector.

  6. A new technique, combined plication-incision (CPI, for correction of penile curvature

    Directory of Open Access Journals (Sweden)

    Hamed Abdalla Hamed

    Full Text Available ABSTRACT Introduction Penile curvature (PC can be surgically corrected by either corporoplasty or plication techniques. These techniques can be complicated by post-operative: penile shortening, recurrent PC, painful/palpable suture knots and erectile dysfunction. Objective To avoid the complications of corporoplasty and plication techniques using a new technique: combined plication-incision (CPI. Materials and Methods Two groups (1&2 were operated upon: group 1 using CPI and group 2 using the 16-dot technique. In CPI, dots were first marked as in 16 dot technique. In each group of 4 dots the superficial layer of tunica albuginea was transversely incised (3-6mm at the first and last dots. Ethibond 2/0, passed through the interior edge of the first incision plicating the intermediate 2 dots and passed out of the interior edge of the last incision, was tightened and ligated. Vicryle 4/0, passed through the exterior edges of the incisions, was tightened and ligated to cover the ethibond knot. Results Twelve (57.1 % participants in group 2 complained of a bothering palpable knot compared to none in group 1 with statistically significant difference (P=0.005. Postoperative shortening (5mm of erect penis, encountered in 9 participants, was doubled in group 2 but with insignificant difference (P>0.05. Post-operative recurrence of PC, was encountered in only 1 (4.8% participant in group 2, compared to none in group 1, with insignificant difference (P>0.05. Post-operative erectile rigidity was normally maintained in all participants. Conclusion The new technique was superior to the 16-dot technique for correction of PC.

  7. Full-Thickness Retinochoroidal Incision in the Management of Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    2015-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes in patients with central retinal vein occlusion (CRVO treated with full-thickness retinochoroidal incisions and to compare whether there is difference in treatment response in ischemic and nonischemic CRVO. Methods. Retrospective study of patients of CRVO receiving full-thickness retinochoroidal incisions in Changhua Christian Hospital. Fluorescein angiography (FA, slit-lamp biomicroscopy, indirect funduscopy, best corrected visual acuity, and central macular thickness (CMT measured by optical coherence tomography were performed pre- and postoperatively. Patients were divided into an ischemic and nonischemic group according to the findings of FA. Patients were followed up for at least 1 year. Results. Twenty-eight eyes (14 ischemic and 14 nonischemic CRVO were included. Functional retinochoroidal venous anastomosis (RCVA was achieved in 48 of the 65 retinochoroidal incisions (73.8%. Central macular thickness (CMT and retinal hemorrhage decreased significantly after the surgery. Significant visual gain was observed postoperatively in the nonischemic group, but not in the ischemic group. Postoperative complications included vitreous hemorrhage (17.8%, neovascular glaucoma (7.1%, and preretinal fibrovasular membrane (10.7%, all of which were in the ischemic group. Conclusions. RCVA formation induced by retinochoroidal incisions could improve venous flow, and decrease CMT and retinal hemorrhage. However, only eyes with nonischemic CRVO showed visual improvement.

  8. The Evolution of the Appendectomy: From Open to Laparoscopic to Single Incision

    Directory of Open Access Journals (Sweden)

    Noah J. Switzer

    2012-01-01

    Full Text Available Beginning with its initial description by Fitz in the 19th century, acute appendicitis has been a significant long-standing medical challenge; today it remains the most common gastrointestinal emergency in adults. Already in 1894, McBurney advocated for the surgical removal of the inflamed appendix and is credited with the initial description of an Open Appendectomy (OA. With the introduction of minimally invasive surgery, this classic approach evolved into a procedure with multiple, smaller incisions; a technique termed Laparoscopic Appendectomy (LA. There is much literature describing the advantages of this newer approach. To name a few, patients have significantly less wound infections, reduced pain, and a reduction in ileus compared with the OA. In the past few years, Single Incision Laparoscopic Appendectomy (SILA has gained popularity as the next major evolutionary advancement in the removal of the appendix. Described as a pioneer in the era of “scarless surgery,” it involves only one transumbilical incision. Patients are postulated to have reduced post-operative complications such as infection, hernias, and hematomas, as well as a quicker recovery time and less post-operative pain scores, in comparison to its predecessors. In this review, we explore the advancement of the appendectomy from open to laparoscopic to single incision.

  9. Designing a mini subcritical nuclear reactor; Diseno de un mini reactor nuclear subcritico

    Energy Technology Data Exchange (ETDEWEB)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M., E-mail: rafelaescobedo@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Jardin Juarez 147, Col. Centro, 98000 Zacatecas, Zac. (Mexico)

    2015-10-15

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of {sup 239}PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of {sup 239}PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k{sub e}-f{sub f}, the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k{sub eff}, the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons {sup 239}PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k{sub eff} was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k{sub eff} of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five

  10. [The "Mini-ICF-Rating for Mental Disorders (Mini-ICF-P)". A short instrument for the assessment of disabilities in mental disorders].

    Science.gov (United States)

    Linden, M; Baron, S

    2005-06-01

    Supplementary to the description of diseases at symptom level, the International Classification of Functioning, Disability and Health (ICF), edited by the WHO, for the first time enables a systematic description also at the level of disabilities and impairments. The Mini-ICF-Rating for Mental Disorders (Mini-ICF-P) is a short observer rating instrument for the assessment of disabilities, especially with regard to occupational functioning. The Mini-ICF-P was first evaluated empirically in 125 patients of a Department of Behavioural Medicine and Psychosomatics. Parallel-test reliability was r = 0.59. Correlates were found with cognitive and motivational variables and duration of sick leave from work. In summary, the Mini-ICF-P is a quick and practicable instrument.

  11. Mini International Neuropsychiatric Interview (MINI: validação de entrevista breve para diagnóstico de transtornos mentais

    Directory of Open Access Journals (Sweden)

    Amorim Patrícia

    2000-01-01

    Full Text Available Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos, compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas. A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudos de validação do instrumento, realizados na Europa e nos EUA. Métodos: Os estudos 1 (França e 2 (EUA testaram a confiabilidade -entre avaliadores e teste-reteste -da versão DSM-III-R do MINI (n=84, sendo 42 pacientes psiquiátricos de cada centro e sua validade com relação ao CIDI (n=346, sendo 296 pacientes psiquiátricos e 50 controles e ao SCID-P (n=370, sendo 308 pacientes psiquiátricos e 62 controles, respectivamente. O estudo 3 testou a validade de diagnósticos gerados por clínicos gerais usando o MINI (DSM-IV com relação aos diagnósticos clínicos habituais de psiquiatras, em 409 pacientes de centros de atenção primária de quatro países (França, Espanha, Itália e Reino Unido. O estudo 4 testou a confiabilidade entre avaliadores (n=20 pacientes psiquiátricos e a validade dos módulos Transtornos Psicóticos, Depressão e Mania do MINI Plus - DSM IV (n=104 pacientes psiquiátricos com relação a dois critérios de referência: diagnósticos do CIDI e diagnósticos clínicos de psiquiatras. Análises quantitativas (índices de concordância e de validade e qualitativas (razões de discordância foram realizadas. Resultados: Os índices de confiabilidade do MINI (estudos 1 e 2 e do MINI Plus (estudo 4 foram globalmente satisfatórios. Comparados a vários critérios de referência (CIDI, SCID-P, opinião de peritos, em diferentes contextos (unidades psiquiátricas e centros de atenção primária, o MINI e o MINI

  12. Techniques for creating inconspicuous face-lift scars: avoiding visible incisions and loss of temporal hair.

    Science.gov (United States)

    Kridel, Russell W H; Liu, Edmund S

    2003-01-01

    Patients seeking rhytidectomy desire an improved neckline, jawline, and midface, but rarely at the price of signs that betray a face-lift, namely, visible incisions. We describe our face-lift incisional planning and the rationale behind specific surgical maneuvers for preventing unwanted sequelae. The telltale signs of poorly placed incisions include temporal hair loss, conspicuous scars, an unnatural appearance to the tragus, and a posterior hairline distorsion. Special considerations are given to the male patient and to the salvage of readily visible incision lines from previous surgery.

  13. PV-hybrid and mini-grid

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the 5th European PV-hybrid and mini-grid conference 29th and 30th April, 2010 in Tarragona (Spain) the following lectures were held: (1) Overview of IEA PVPS Task 11 PV-hybrid systems within mini grids; (2) Photovoltaic revolution for deployment in developing countries; (3) Legal and financial conditions for the sustainable operation of mini-grids; (4) EU instruments to promote renewable energies in developing countries; (5) PV hybridization of diesel electricity generators: Conditions of profitability and examples in differential power and storage size ranges; (6) Education suit of designing PV hybrid systems; (7) Sustainable renewable energy projects for intelligent rural electrification in Laos, Cambodia and Vietnam; (8) Techno-economic feasibility of energy supply of remote villages in Palestine by PV systems, diesel generators and electric grid (Case studies: Emnazeil and Atouf villages); (9) Technical, economical and sustainability considerations of a solar PV mini grid as a tool for rural electrification in Uganda; (10) Can we rate inverters for rural electrification on the basis of energy efficiency?; (11) Test procedures for MPPT charge controllers characterization; (12) Energy storage for mini-grid stabilization; (13) Redox flow batteries - Already an alternative storage solution for hybrid PV mini-grids?; (14) Control methods for PV hybrid mini-grids; (15) Partial AC-coupling in mini-grids; (15) Normative issues of small wind turbines in PV hybrid systems; (16) Communication solutions for PV hybrid systems; (17) Towards flexible control and communication of mini-grids; (18) PV/methanol fuel cell hybrid system for powering a highway security variable message board; (19) Polygeneration smartgrids: A solution for the supply of electricity, potable water and hydrogen as fuel for transportation in remote Areas; (20) Implementation of the Bronsbergen micro grid using FACDS; (21) A revisited approach for the design of PV wind hybrid systems; (22

  14. Channel Incision Driven by Suburbanization: Impacts to Riparian Groundwater Flow and Overbank Flow Frequency

    Science.gov (United States)

    Bowles, C. J.; Lawrence, R. L.; Noll, C.; Hancock, G. S.

    2005-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that stream incision has lowered floodplain water tables and decreased the overbank flow frequency. The monitored stream is a tributary to the James River draining 1.3 km2 of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one meter high knickpoint at a rate of ~1.5 m/yr, primarily during high flow events. We installed 63 wells in six stream-perpendicular transects as well as a cluster of wells around the knickpoint to assess water table elevations beneath the floodplain adjacent to the incising stream. Two transects are located 30 and 50 m upstream of the knickpoint in the unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream in the incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table changes. Erosion pins were installed and channel cross-sections surveyed to determine streambed stability. Significant differences are observed in bank morphology and groundwater flow above vs. below the knickpoint. Above the knickpoint, the banks are stable, ~3 m wide, and ~0.3 m deep, and widen and deepen slightly toward the knickpoint. The water table is relatively flat and is 0.2-0.4 m below the floodplain surface, and groundwater contours suggest flow is parallel to the stream direction. The water table responds immediately to precipitation events, and rises to the floodplain surface in significant rainfall events. Immediately downstream of the knickpoint, channel width increases by about a meter, and stream depth increases to ~1.5 meters. The water table immediately below the knickpoint possesses a steep gradient, and is up to one meter below the floodplain

  15. The Mini-Cog, Clock Drawing Test, and the Mini-Mental State Examination in a German memory clinic: specificity of separation dementia from depression.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2013-01-01

    The aim of this study was to assess the specificities of the Mini-Cog, the Clock Drawing Test (CDT), and the Mini-Mental State Examination (MMSE) against depression and healthy controls in a German Memory Clinic. Furthermore, we analyzed the specificities of all three screening instruments in dependence of actual depression severity. Data from 142 depressed elderly, 438 dementia patients, and 64 healthy controls were retrospectively analyzed. The CDT and an extraction of the three-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Depression severity was rated by either the Beck Depression Inventory (BDI) or the Geriatric Depression Scale (GDS) depending on the age of the patients. The Mini-Cog achieved a specificity of 79.6% against depressed elderly and 100.0% against healthy subjects (p Mini-Cog and the CDT, but also showed the lowest sensitivity for the detection of dementia. Surprisingly, the depression severity had no effect on the specificity of the Mini-Cog and the CDT, only the MMSE was susceptible for the depression severity. Although the MMSE showed higher specificities, the weighting between the sensitivities and specificities in all tests prove again the Mini-Cog as a short, valid, and sensitive screening tool.

  16. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  17. Stratigraphic architecture of back-filled incised-valley systems: Pennsylvanian-Permian lower Cutler beds, Utah, USA

    Science.gov (United States)

    Wakefield, Oliver J. W.; Mountney, Nigel P.

    2013-12-01

    The Pennsylvanian to Permian lower Cutler beds collectively form the lowermost stratigraphic unit of the Cutler Group in the Paradox Basin, southeast Utah. The lower Cutler beds represent a tripartite succession comprising lithofacies assemblages of aeolian, fluvial and shallow-marine origin, in near equal proportion. The succession results from a series of transgressive-regressive cycles, driven by repeated episodes of climatic variation and linked changes in relative sea-level. Relative sea-level changes created a number of incised-valleys, each forming through fluvial incision during lowered base-level. Aeolian dominance during periods of relative sea-level lowstand aids incised-valley identification as the erosive bounding surface juxtaposes incised-valley infill against stacked aeolian faces. Relative sea-level rises resulted in back-flooding of the incised-valleys and their infill via shallow-marine and estuarine processes. Back-flooded valleys generated marine embayments within which additional local accommodation was exploited. Back-filling is characterised by a distinctive suite of lithofacies arranged into a lowermost, basal fill of fluvial channel and floodplain architectural elements, passing upwards into barform elements with indicators of tidal influence, including inclined heterolithic strata and reactivation surfaces. The incised-valley fills are capped by laterally extensive and continuous marine limestone elements that record the drowning of the valleys and, ultimately, flooding and accumulation across surrounding interfluves (transgressive surface). Limestone elements are characterised by an open-marine fauna and represent the preserved expression of maximum transgression.

  18. The boomerang incision for periareolar breast malignancies.

    Science.gov (United States)

    Tan, Mona P

    2007-11-01

    Breast-conservation surgery has been shown to be equivalent to mastectomy in terms of long-term survival for the treatment of breast cancer. Various techniques have been described on how to achieve clear margins and good cosmetic outcomes and therefore expand the indications for breast conservation. A novel incision is detailed to augment the options already available.

  19. Incisional hernia after upper abdominal surgery: A randomised controlled trial of midline versus transverse incision

    NARCIS (Netherlands)

    J.A. Halm (Jens); H. Lip (Harm); P.I.M. Schmitz (Paul); J. Jeekel (Hans)

    2009-01-01

    textabstractObjectives: To determine whether a transverse incision is an alternative to a midline incision in terms of incisional hernia incidence, surgical site infection, postoperative pain, hospital stay and cosmetics in cholecystectomy. Summary background data: Incisional hernias after midline

  20. Phenomenon of mucous retention in the incisive canal.

    Science.gov (United States)

    Keith, D A

    1979-11-01

    Mucous glands are rarely found in the anterior palate but may be observed in the incisive canal. A case history is presented of a lesion that resembled a nasopalatine cyst both clinically and radiographically but which was in fact an intra-bony extravasation phenomenon.

  1. Comparison of first-intention healing of carbon dioxide laser, 4.0-MHz radiosurgery, and scalpel incisions in ball pythons (Python regius).

    Science.gov (United States)

    Hodshon, Rebecca T; Sura, Patricia A; Schumacher, Juergen P; Odoi, Agricola; Steeil, James C; Newkirk, Kim M

    2013-03-01

    To evaluate first-intention healing of CO(2) laser, 4.0-MHz radiowave radiosurgery (RWRS), and scalpel incisions in ball pythons (Python regius). 6 healthy adult ball pythons. A skin biopsy sample was collected, and 2-cm skin incisions (4/modality) were made in each snake under anesthesia and closed with surgical staples on day 0. Incision sites were grossly evaluated and scored daily. One skin biopsy sample per incision type per snake was obtained on days 2, 7, 14, and 30. Necrotic and fibroplastic tissue was measured in histologic sections; samples were assessed and scored for total inflammation, histologic response (based on the measurement of necrotic and fibroplastic tissues and total inflammation score), and other variables. Frequency distributions of gross and histologic variables associated with wound healing were calculated. Gross wound scores were significantly greater (indicating greater separation of wound edges) for laser incisions than for RWRS and scalpel incisions at all evaluated time points. Necrosis was significantly greater in laser and RWRS incisions than in scalpel incision sites on days 2 and 14 and days 2 and 7, respectively; fibroplasia was significantly greater in laser than in scalpel incision sites on day 30. Histologic response scores were significantly lower for scalpel than for other incision modalities on days 2, 14, and 30. In snakes, skin incisions made with a scalpel generally had less necrotic tissue than did CO(2) laser and RWRS incisions. Comparison of the 3 modalities on the basis of histologic response scores indicated that use of a scalpel was preferable, followed by RWRS and then laser.

  2. Smaller incision size leads to higher predictability in microcoaxial cataract surgery.

    Science.gov (United States)

    Klamann, Matthias K J; Gonnermann, Johannes; Maier, Anna-Karina B; Torun, Necip; Bertelmann, Eckart

    2013-01-01

    The aim of the study was to compare the clinical outcomes of a 1.8 mm, 2.2 mm, and 2.75 mm microcoaxial cataract surgery system. METHODS. In this retrospective study, 129 eyes of 129 patients were included. Patients underwent phacoemulsification using a Stellaris system or an Infiniti system. The incision size was 1.8 mm, 2.2 mm, or 2.75 mm, respectively. Subjects were examined before surgery and 4 weeks after. The surgically induced astigmatism (SIA) was examined. The SIA in the 1.8 mm group was statistically lower compared to the 2.2 mm group (p=0.046) and the 2.75 mm group (p=0.017). There was no significant difference between the 2.2 mm group and the 2.75 mm group. With the use of appropriate support systems, 1.8 mm incisions appear to result in less SIA than 2.2 mm and 2.75 mm incisions. Advantages may arise from this, especially in the implantation of aspheric, toric, or multifocal lenses.

  3. Validation and cultural adaptation of the Arabic versions of the Mini-Mental Status Examination - 2 and Mini-Cog test.

    Science.gov (United States)

    Albanna, Mohammad; Yehya, Arij; Khairi, Abdalla; Dafeeah, Elnour; Elhadi, Abdelsalam; Rezgui, Lamia; Al Kahlout, Shahada; Yousif, Adil; Uthman, Basim; Al-Amin, Hassen

    2017-01-01

    The elderly population is increasing around the world, and the prevalence of dementia increases with age. Hence, it is expected that the number of people with dementia will increase significantly in the coming years. The Mini-Mental Status Examination - 2 (MMSE-2) and Mini-Cog are widely used tests to screen for dementia. These scales have good reliability and validity and are easy to administer in clinical and research settings. The purpose of this study was to validate the Arabic versions of MMSE-2 and Mini-Cog. These scales were assessed against the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision ( DSM-IV-TR ) criteria for dementia, as the gold standard. The standard versions of the MMSE-2 and Mini-Cog were translated to Arabic following the back-translation method. Then, a trained rater administered these tests to 134 Arab elderly aged >60 years. A physician, blind to the results of these two tests, assessed the participants for vascular dementia or probable Alzheimer's disease, based on the DSM-IV-TR criteria. The sample included 67.2% Qataris. The mean age was 74.86 years (standard deviation =7.71), and 61.9% did not attend school. The mean of the adjusted scores of MMSE-2 based on age and education level was 19.60 (standard deviation =6.58). According to DSM-IV-TR , 17.2% of the participants had dementia. Sensitivity and specificity of the MMSE-2 and the Mini-Cog together were 71.4% and 61.6%, respectively, which were better than those of each test alone. Together, the Arabic versions of MMSE-2 and Mini-Cog are good screening tools for cognitive impairment in Arabs.

  4. A STUDY ON EFFICACY OF MANUAL SMALL INCISION CATARACT SURGERY BY TEMPORAL APPROACH

    Directory of Open Access Journals (Sweden)

    Vinodhini Kannan

    2018-01-01

    Full Text Available BACKGROUND Manual Small Incision Cataract Surgery (MSICS is a well-known technique of cataract surgery owing to its advantage of a selfsealing suture less incision with least surgically induced astigmatism at a low cost. It is a safe, simple, consistent, stable and cost-effective technique with various modifications that involve site, size, type of incision and method of nucleus delivery. One such modification is Temporal Incision MSICS, where the cataract surgery is done by a temporal approach, which is equally good compared to the superior incision. This study was done retrospectively to analyse the visual outcome of patients operated by Manual SICS - Temporal Approach, using the WHO criteria and to establish its efficacy as a good surgical technique. MATERIALS AND METHODS Records of patients operated for senile cataract by a single surgeon by Temporal MSICS using a temporal sclerocorneal incision of 6-6.5 mm, during a 1-year period, were analysed retrospectively. Post-operative followup records of POD-1 and subsequent follow-ups at 1 st week and 6 th week were recorded for visual outcome. RESULTS Out of the 83 cases analysed retrospectively, majority of them were found to be between 61-70 years with a female Preponderance. Most of the cases were found to have senile immature cataract (55 patients, with Grade III nuclear sclerosis (52 cases. The pre-operative visual acuity was poor <6/60 in 72 cases (86.7% and borderline in 11 cases (14.5%. 55 cases (66.3% had a 6.5 mm scleral incision and the remaining 28 cases (33.7% had a 6 mm incision. Average duration of surgery noted was 8.35 minutes. Striate Keratopathy was the most common 1 st POD complication followed by corneal oedema. Striate keratopathy was the most common complication at the 1 st week followup followed by pigment dispersion. Majority of cases (76 cases were found to have been complication free at the end of 6 weeks. At the end of 6 weeks post-operatively as per records, 80 cases

  5. Reasons for mini-implants failure: choosing installation site should be valued!

    Directory of Open Access Journals (Sweden)

    Alberto Consolaro

    2014-04-01

    Full Text Available Mini-implant loss is often associated with physical and mechanical aspects that result from choosing an inappropriate placement site. It is worth highlighting that: a Interdental alveolar bone crests are flexible and deformable. For this reason, they may not offer the ideal absolute anchorage. The more cervical the structures, the more delicate they are, thus offering less physical support for mini-implant placement; b Alveolar bone crests of triangular shape are more deformable, whereas those of rectangular shape are more flexible; c The bases of the alveolar processes of the maxilla and the mandible are not flexible, for this reason, they are more likely to receive mini-implants; d The more cervical a mini-implant is placed, the higher the risk of loss; the more apical a mini-implant is placed, the better its prognosis will be; e 3D evaluations play a major role in planning the use of mini-implants. Based on the aforementioned considerations, the hypotheses about mini-implant loss are as follows: 1 Deflection of maxillary and mandibular alveolar processes when mini-implants are more cervically placed; 2 Mini-implants placed too near the periodontal ligament, with normal intra-alveolar tooth movement; 3 Low bone density, low thickness and low alveolar bone volume; 4 Low alveolar cortical bone thickness; 5 Excessive pressure inducing trabecular bone microfracture; 6 Sites of higher anatomical weakness in the mandible and the maxilla; 7 Thicker gingival tissue not considered when choosing the mini-implant.

  6. Oral subcutaneous midline leiomyomatous hamartoma presenting as congenital incisive papilla overgrowth in a toddler

    Directory of Open Access Journals (Sweden)

    Ashish Loomba

    2017-01-01

    Full Text Available Congenital soft-tissue tumors of oral cavity are mostly hyperplastic and benign in nature. This article presents an unusual case of congenital subcutaneous hamartoma of incisive papilla in a 2-year-old female child causing feeding and breathing difficulty. Total excisional biopsy was done under local anesthesia. Histopathology of tissue in reticulin-stained slide showed the presence of immature muscle fibers whereas Masson's trichrome stain revealed collagen fibers and smooth muscles confirming the diagnosis of oral midline subcutaneous smooth muscle (leiomyomatous hamartoma of incisive papilla. It is important for dental professionals to be aware of this oral lesion present from birth mimicking overgrowth of incisive papilla, by its presentation, differential diagnosis, histopathology, and management.

  7. High transverse skin incisions may reduce wound complications in obese women having cesarean sections: a pilot study.

    Science.gov (United States)

    Walton, Robert B; Shnaekel, Kelsey L; Ounpraseuth, Songthip T; Napolitano, Peter G; Magann, Everett F

    2017-11-01

    Women having cesarean section have a high risk of wound complications. Our objective was to determine whether high transverse skin incisions are associated with a reduced risk of cesarean wound complications in women with BMI greater than 40. A retrospective cohort study was undertaken of parturients ages 18-45 with BMI greater than 40 having high transverse skin incisions from January 2010 to April 2015 at a tertiary maternity hospital. Temporally matched controls had low transverse skin incisions along with a BMI greater than 40. The primary outcome, wound complication, was defined as any seroma, hematoma, dehiscence, or infection requiring opening and evacuating/debriding the wound. Secondary outcomes included rates of endometritis, number of hospital days, NICU admission, Apgar scores, birth weight, and gestational age at delivery. Analysis of outcomes was performed using two-sample t-test or Wilcoxon rank-sum test for continuous variables and Fisher's exact test for categorical variables. Thirty-two women had high transverse incisions and were temporally matched with 96 controls (low transverse incisions). The mean BMI was 49 for both groups. There was a trend toward reduced wound complications in those having high transverse skin incisions, but this did not reach statistical significance (15.63% versus 27.08%, p = .2379). Those having high transverse skin incisions had lower five minute median Apgar scores (8.0 versus 9.0, p = .0021), but no difference in umbilical artery pH values. The high transverse group also had increased NICU admissions (28.13% versus 5.21%, p = .0011), and early gestational age at delivery (36.8 versus 38.0, p = .0272). High transverse skin incisions may reduce the risk of wound complications in parturients with obesity. A study with more power should be considered.

  8. S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative.

    Science.gov (United States)

    Kordzadeh, Ali; Panayiotopolous, Yiannis

    2017-10-01

    The objective of this study is to test the null hypothesis that an S-shaped surgical incision versus conventional (straight) skin incision in the creation of autogenous radiocephalic arteriovenous fistulas (RCAVFs) have no impact on the primary end-point of primary functional maturation and secondary end points of stenosis and thrombosis. A prospective observational comparative consecutive study with intention-to-treat on individuals undergoing only radiocephalic arteriovenous fistula (RCAVFs) over a period of 12 months was conducted. Variables on patient's demographics, comorbidities, anesthesia type, mean arterial blood pressure, thrill, laterality, cephalic vein and radial artery diameter were collated. The test of probability was assessed through Chi-Square, Kaplan-Meier survival estimator and Log-Rank analysis. Total of n = 83 individuals with median age of 67 years (IQR, 20-89) and male predominance 83% during this period were subjected to RCAVF formation. Total of n = 45 patients in straight skin incision were compared to n = 38 individuals in S-shaped group. Despite equal prevalence of demographics, comorbidities, anesthesia type, mean arterial blood pressure (MAP), thrill, laterality, cephalic vein and radial artery diameter ( p  > 0.05) higher incidence of juxta-anastomotic stenosis was noted in the straight skin incision group ( p  = 0.029) in comparative and survival analysis (Log-Rank, p  = 0.036). The maturation of the entire cohort was 69% (S-shaped 76% vs. straight group 62%) (p > 0.05). The outcome of this study demonstrates that S-shaped surgical skin incision is associated with a lower incidence of stenosis in comparison to straight incision type in RCAVF formation.

  9. Congenital hypogonadotropic hypogonadism: implications of absent mini-puberty.

    Science.gov (United States)

    Dwyer, Andrew A; Jayasena, Channa N; Quinton, Richard

    2016-06-01

    The phenomenon known as "mini-puberty" refers to activation of the neonatal hypothalamo-pituitary axis causing serum concentrations of gonadotrophins and testosterone (T) to approach adult male levels. This early neonatal period is a key proliferative window for testicular germ cells and immature Sertoli cells. Although failure to spontaneously initiate (adolescent) puberty is the most evident consequence of a defective gonadotropin-releasing hormone (GnRH) neurosecretory network, absent mini-puberty is also likely to have a major impact on the reproductive phenotype of men with congenital hypogonadotrophic hypogonadism (CHH). Furthermore, the phase of male mini-puberty represents a key window-of-opportunity to identify congenital GnRH deficiency (either isolated CHH, or as part of combined pituitary hormone deficiency) in childhood. Among male neonates exhibiting "red flag" indicators for CHH (i.e. maldescended testes with or without cryptorchidism) a single serum sample (between 4-8 weeks of life) can pinpoint congenital GnRH deficiency far more rapidly and with much greater accuracy than dynamic tests performed in later childhood or adolescence. Potential consequences for missing absent mini-puberty in a male neonate include the lack of monitoring of pubertal progression/lack of progression, and the missed opportunity for early therapeutic intervention. This article will review our current understanding of the mechanisms and clinical consequences of mini-puberty. Furthermore, evidence for the optimal clinical management of patients with absent mini-puberty will be discussed.

  10. Virtual laboratory of electrical mini-grids with distributed generation

    International Nuclear Information System (INIS)

    Menezes Ramos, Vanessa; Barros Galhardo, Marcos André; Oliveira Barbosa, Claudomiro Fábio de; Tavares Pinho, João

    2015-01-01

    This paper presents a computing tool called Virtual Laboratory de Minirredes (Virtual Laboratory of Mini-grids). Using the virtual environment of the developed tool, it is possible to make remote connection/disconnection of switches and loads (resistive, inductive, capacitive and non-linear) at strategic points of the electric mini-grid with hybrid distributed generation systems (solar photovoltaic-diesel). The mini-grid has a length of about 1 km and is installed in the test area of the Grupo de Estudios e Desenvolvimento de Alternativas Exergética (GEDAE) of the Universidade Federal do Pará, located in the city of Belém, Pará, Brazil. The developed tool has communication functions with electric parameters transducers and programmable logic controllers (PLCs). This communication enables the opening and closing of contactors, resulting in different settings for the mini-grid. In addition to that, based on the proposed configuration by the user, the real-time operation status of mini-grid is presented in a graphic interface (for example, monitored electric parameters, distributed generators connected, status of disconnected switches, etc.) and the acquired data is stored. The use of the computing tool also focuses on the construction of a database, in order to obtain knowledge about the mini-grid performance under various conditions that can be set, depending on the operational strategy adopted, based on the choice of the layout, loads and power sources used in the mini-grid. (full text)

  11. Rapid fluvial incision of a late Holocene lava flow: Insights from LiDAR, alluvial stratigraphy, and numerical modeling

    Science.gov (United States)

    Sweeney, Kristin; Roering, Joshua J.

    2016-01-01

    Volcanic eruptions fundamentally alter landscapes, paving over channels, decimating biota, and emplacing fresh, unweathered material. The fluvial incision of blocky lava flows is a geomorphic puzzle. First, high surface permeability and lack of sediment should preclude geomorphically effective surface runoff and dissection. Furthermore, past work has demonstrated the importance of extreme floods in driving incision via column toppling and plucking in columnar basalt, but it is unclear how incision occurs in systems where surface blocks are readily mobile. We examine rapid fluvial incision of the Collier lava flow, an andesitic Holocene lava flow in the High Cascades of Oregon. Since lava flow emplacement ∼1600 yr ago, White Branch Creek has incised bedrock gorges up to 8 m deep into the coherent core of the lava flow and deposited >0.2 km3 of sediment on the lava flow surface. Field observation points to a bimodal discharge regime in the channel, with evidence for both annual snowmelt runoff and outburst floods from Collier glacier, as well as historical evidence of vigorous glacial meltwater. To determine the range of discharge events capable of incision in White Branch Creek, we used a mechanistic model of fluvial abrasion. We show that the observed incision implies that moderate flows are capable of both initiating channel formation and sustaining incision. Our results have implications for the evolution of volcanic systems worldwide, where glaciation and/or mass wasting may accelerate fluvial processes by providing large amounts of sediment to otherwise porous, sediment-starved landscapes.

  12. Mini AERCam Inspection Robot for Human Space Missions

    Science.gov (United States)

    Fredrickson, Steven E.; Duran, Steve; Mitchell, Jennifer D.

    2004-01-01

    The Engineering Directorate of NASA Johnson Space Center has developed a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam free flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35 pound, 14 inch AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, imaging, power, and propulsion subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations including automatic stationkeeping and point-to-point maneuvering. Mini AERCam is designed to fulfill the unique requirements and constraints associated with using a free flyer to perform external inspections and remote viewing of human spacecraft operations. This paper describes the application of Mini AERCam for stand-alone spacecraft inspection, as well as for roles on teams of humans and robots conducting future space exploration missions.

  13. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    OpenAIRE

    Parvu Valentin; Dugue Geoffrey; Albanese John; Bajart Ann M; Lee Edwin

    2009-01-01

    Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate dept...

  14. Characteristics of Bone Injuries Resulting from Knife Wounds Incised with Different Forces.

    Science.gov (United States)

    Humphrey, Caitlin; Kumaratilake, Jaliya; Henneberg, Maciej

    2017-11-01

    The aim of this research was to experimentally determine the characteristics of incised bone wounds, which are commonly found in defense injuries. A specially constructed pivoting arm device was used to inflict wounds with controlled forces and direction. Five knives were selected to inflict the wounds on porcine forelimbs. Eight incised wounds were made per knife per force. A larger knife and a greater force caused longer and wider bone wounds. Comparisons of individual knives at the two forces produced varying results in the bone wounds. A correlation was seen between the force and the length (r = 0.69), width (r = 0.63), and depth (r = 0.57) of bone wounds. Serrated-edge and nonserrated knives can be distinguished from the appearance of the wound. The outcomes may be applicable in forensic investigations to ascertain the forces associated with incised wounds and identify the specific knife used. © 2017 American Academy of Forensic Sciences.

  15. Mini-chamber, an advanced protection concept for NIF

    International Nuclear Information System (INIS)

    Peterson, P.F.; Scott, J.M.

    1996-01-01

    Inertial confinement fusion (ICF) target debris and ablated near-target materials pose the primary threat to the National Ignition Facility (NIF) final optics debris shields, as well as a major challenge in future inertial fusion energy (IFE) power plants. This work discusses a NIF 'mini-chamber,' designed to mitigate the debris threat. Although the NIF base-line design protects against debris using a frost-protected target positioner and refractory first-wall coatings, the mini-chamber provides important flexibility in three areas: debris-shield protection from beyond-design basis shots (i.e. heavy hohlraums, special diagnostics, shields); fielding of large experiments with significant surface ablation; and studying key ablation and gas-dynamics issues for liquid-wall IFE power plants. Key mini-chamber modeling results are presented, followed by discussion of equipment requirements for fielding a NIF mini-chamber. 7 refs., 3 figs

  16. Mini-Implants: New Possibilities in Interdisciplinary Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Biju Sebastian

    2014-01-01

    Full Text Available The introduction of mini-implants has broadened the range of tooth movements possible by fixed appliance therapy alone. The limits of fixed orthodontic treatment have become more a matter of facial appearance than anchorage. Many complex cases which would previously have required surgery or functional appliances can now be treated with fixed appliance therapy using mini-implants. A mutilated dentition case where mini-implants were used to provide anchorage for intrusion of molars and retraction of anterior teeth is reported here to illustrate this point.

  17. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed......PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...

  18. Single incision thoracoscopic sympathectomy for palmar and axillary hyperhidrosis

    Directory of Open Access Journals (Sweden)

    Aram Baram

    2014-02-01

    Full Text Available Background: Primary hyperhidrosis is characterized by excessive sweating beyond physiological needs. It is a common disease (incidence 2.8% that causes intense discomfort for patients. In the last decade, advantages of Single-Incision Thoracoscopic Sympathectomy have become clear, particularly in decreasing morbidity of sympathectomy. Patients and methods: From January 2010 to December 2012, 39 patients (29 females and 10 males with primary palmar or axillary hyperhidrosis were treated by thoracoscopic sympathectomy. The age ranged from 18 to 40 years with a mean of 26.28 years. We used single incision thoracoscopic electrocoagulation through 10 mm incision for thoracic sympathetic chain (T2–T4. Results: The mean follow-up was 23.6 ± 14.2 months (range = 4–24 months. A total of 97.42% of patients were satisfied with the results. A total of 72.5% of patients had cure, one patient (2.5% and another patient (2.5% presented with recurrent axillary hyperhidrosis. The morbidity was 10.2% with no mortality. Percentage of compensatory sweating and gustatory sweating were 5.1% (p = .353 and 2.5% (p = .552, respectively. The result of sympathectomy in patients with both palmar and axillary hyperhidrosis was significantly better (17, 43.58% compared to palmar type (14, 35.89% or axillary type (7, 17.94%. Conclusion: Thoracoscopic sympathectomy is a simple, safe, and cost-effective therapy with good results and low complications.

  19. Energy efficient mini bars in hotel rooms; Energieffektive minibarer til hotelvaerelser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    The project 'Energy-efficient mini bars for hotel rooms' is carried out from February December 2005. The project is financed by Elfor's PSO funds and also by the participants in the project, HORESTA and Teknologisk Institut. Mini bars consume up to 10% of the total electricity costs of a hotel. Therefore, the energy consumption of mini bars has been brought into focus in this project. The existing mini bar market has been analysed and measurements have been carried out on the type of mini bars that are used most often. In that way, energy consumption, net volume, energy efficiency, energy labelling, noise level and cooling capacity have been determined. In the course of the project, mini bars from IndelB, Domestic and Vibocold have been tested. With regard to energy consumption, the test results showed large deviations from the consumption stated by the manufacturer. Only 1 of the 6 tested mini bars received an energy label B - the others were labelled with F or G. Therefore, there is a great potential for developing more energy efficient mini bars. A list covering the energy consumption, energy labelling, noise level etc. of the tested mini bars and a guide to new purchases can be found on HORESTA's homepage www.horesta.dk. (au)

  20. Treatment for incarcerated indirect hernia with “Cross-Internal Ring” inguinal oblique incision in children

    Directory of Open Access Journals (Sweden)

    Xue-Qiang Yan

    2017-01-01

    Full Text Available Background: This study aims to evaluate the utility of the “Cross-Internal Ring” inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH complicated with severe abdominal distension. Materials and Methods: Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the “Cross-Internal Ring” inguinal oblique incision. Results: There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6–18 months. No recurrence or iatrogenic cryptorchidism happened. Conclusion: “Cross-Internal Ring” inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  1. Tubularized incised plate technique for recurrent hypospadias: a ...

    African Journals Online (AJOL)

    management of recurrent hypospadias. Summary background ... The potential advantages of tubularized incised plate .... after a mean duration of 4.9 ± 3.1 years from the previous repair (Table 2). .... erection and the risk of infection, especially in patients older than 15 .... However, previous surgery often limits the availability ...

  2. Effects of Bank Vegetation and Incision on Erosion Rates in an Urban Stream

    Directory of Open Access Journals (Sweden)

    Emily Arnold

    2018-04-01

    Full Text Available Changing land-use associated with urbanization has resulted in shifts in riparian assemblages, stream hydraulics, and sediment dynamics leading to the degradation of waterways. To combat degradation, restoration and management of riparian zones is becoming increasingly common. However, the relationship between flora, especially the influence of invasive species, on sediment dynamics is poorly understood. Bank erosion and turbidity were monitored in the Tookany Creek and its tributary Mill Run in the greater Philadelphia, PA region. To evaluate the influence of the invasive species Reynoutria japonica (Japanese knotweed on erosion, reaches were chosen based on their riparian vegetation and degree of incision. Bank pins and turbidity loggers were used to estimate sediment erosion. Erosion calculations based on bank pins suggest greater erosion in reaches dominated by knotweed than those dominated by trees. For a 9.5-month monitoring period, there was 29 cm more erosion on banks that were also incised, and 9 cm more erosion in banks with little incision. Turbidity responses to storm events were also higher (77 vs. 54 NTU (nephelometric turbidity unit in reaches with knotweed, although this increase was found when the reach dominated by knotweed was also incised. Thus, this study linked knotweed to increased erosion using multiple methods.

  3. Development on mini X-ray diode

    International Nuclear Information System (INIS)

    Jiang Shaoen; Sun Kexu; Peng Nengling; Huang Tianxuan; Cui Yanli; Yi Rongqing; Chen Jiusen

    2004-01-01

    The mini X-ray diode (M-XRD) was developed, and was used in mini soft X-ray spectrometer. Compared with traditional XRD, M-XRD's volume reduces to 1/30. M-XRD's property was experimentally examined on Shenguang II laser facility. The experimental results indicated that the temporal response and sensitivity of M-XRD are basically consistent with traditional XRD. The equivalent circuit of XRD was analyzed, and its response time and linear saturated current were calculated. (authors)

  4. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Science.gov (United States)

    Camacho, Macario; Zaghi, Soroush; Chang, Edward T.; Song, Sungjin A.; Szelestey, Blake; Certal, Victor

    2016-01-01

    Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes) in adult obstructive sleep apnea (OSA) patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review) for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm) or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed. PMID:26925105

  5. Mini Tracheostomy for Obstructive Sleep Apnea: An Evidence Based Proposal

    Directory of Open Access Journals (Sweden)

    Macario Camacho

    2016-01-01

    Full Text Available Objective. To search for articles evaluating the use of tracheostomies (either permanent stomas or tracheostomy tubes in adult obstructive sleep apnea (OSA patients and to evaluate the potential for the use of mini tracheostomies as treatment for OSA. Study Design. Systematic review. Methods. Nine databases were searched from inception through July 21, 2015. Results. The overall tracheostomy search yielded 516 articles, of which eighteen studies provided polysomnographic data. No study was identified (empty review for the use of mini tracheostomies for treating OSA. The mini tracheostomy search yielded ninety-five articles which describe findings for either mini tracheostomy kits (inner cannula diameter of 4 mm or the performance of mini tracheotomies. Six articles described the use of mini tracheostomies as a temporary procedure to relieve acute upper airway obstruction and none described the use for OSA. For tracheostomy stomal sites, suturing the skin directly to the tracheal rings with defatting can minimize stomal site collapse. The smallest tracheostomy stomal size that can successfully treat OSA has not been described. Conclusion. Mini tracheostomies as small as 4 mm have been successfully used in the short term to relieve upper airway obstruction. Given that polysomnography data are lacking, additional research is needed.

  6. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  7. Berkeley mini-collider

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1984-06-01

    The Berkeley Mini-Collider, a heavy-ion collider being planned to provide uranium-uranium collisions at T/sub cm/ less than or equal to 4 GeV/nucleon, is described. The central physics to be studied at these energies and our early ideas for a collider detector are presented

  8. Cost assessment of instruments for single-incision laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Henriksen, Nadia A; Al-Tayar, Haytham; Rosenberg, Jacob

    2012-01-01

    Specially designed surgical instruments have been developed for single-incision laparoscopic surgery, but high instrument costs may impede the implementation of these procedures. The aim of this study was to compare the cost of operative implements used for elective cholecystectomy performed...

  9. Perlindungan Hukum Hak Kekayaan Intelektual (Hki) Dalam Waralaba Retail Mini Market Di Yogyakarta Mini Market Di Yogyakarta

    OpenAIRE

    Hariyanto Hariyanto, S.H., M.KN

    2009-01-01

    The Law Protection Intellectual Property Right in Mini Market Retail Franchise in YogyakartaFranchise business is more happening in Indonesia. This fast development indicates an interesting investment which on the same time helps the business subjects in starting their own business with a low risk. The franchise business which commonly stable is retail business. One of retail business which serves the main needs and daily needs is mini market Alfamart and Indomaret.This research aims to ident...

  10. Orthodontic mechanics using mini-implant measured by FBG

    Science.gov (United States)

    Trannin, Pamela G.; Milczewski, Maura S.; de Oliveira, Walmir; Guariza Filho, Odilon; Lopes, Stephani C. P. S.; Kalinowski, Hypolito J.

    2015-07-01

    The magnitude of the force generated during orthodontic mechanics anchored in mini-implant in a maxilla model was analyzed. Data was collected during the insertion of the mini-implant and at the moment of applying forces to the structure of the maxilla and dentition. To obtain quantitative results, the Fibre Bragg Gratings (FBG) were inserted in an elastomeric material reproducing a maxilla model. It was observed levels of forces of approximately 3,78N next to the root of first premolar by the insertion of the mini-implant and different levels of the force to different orthodontic mechanics applied on the dental system.

  11. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.

    Science.gov (United States)

    Kim, Eun Chul; Byun, Yong Soo; Kim, Man Soo

    2011-10-01

    To compare the efficacy of microincision and small-incision coaxial phacoemulsification in treating hard cataracts using different ultrasound power modes. Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. Randomized clinical trial. Eyes with hard cataract were randomized to have an initial incision of 1.80 mm, 2.20 mm, or 2.75 mm. The eyes in each group were equally randomized to treatment with burst, pulse, or continuous mode. Ultrasound time (UST), mean cumulative dissipated energy (CDE), corrected distance visual acuity (CDVA), surgically induced corneal astigmatism, incisional and central corneal thickness (CCT), and endothelial cell counts were evaluated. The study enrolled 180 eyes, 60 in each group. Two months postoperatively, there were no statistically significant differences in UST, CDE, CDVA, CCT, or percentage endothelial cell loss between the 3 incision groups. The 2.75 mm incision induced more astigmatism at 2 months and less incisional corneal edema at 1 week than the 1.80 mm or 2.20 mm incision (Phard cataract. The intraoperative energy use and ocular damage was less with the pulse and burst modes than with the continuous mode. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.

    Science.gov (United States)

    Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad

    2012-11-01

    We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.

  13. Initial validation of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale: study of Portuguese end-of-life cancer patients.

    Science.gov (United States)

    Pereira, Filomena Moreira Pinto; Santos, Célia Samarina Vilaça de Brito

    2014-10-01

    The Mini-Mental Adjustment to Cancer Scale (Mini-MAC) is a 29-item instrument designed to evaluate the responses developed by cancer patients during their mental adjustment to diagnosis and treatment. This study aims to validate the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) translated and adapted to the Portuguese language and culture, in end-of-life cancer patients receiving palliative care. The instrument was administered to 346 Portuguese end-of-life cancer patients, receiving care through outpatient visits or admitted into palliative care units, without cognitive symptoms and with symptoms under control. A cross-sectional validation study using orthogonal rotation through the varimax method followed by convergent and discriminant validity. The analysis of the main components confirms the existence of five factors, demonstrating the validity of the construct, with good internal consistency in the subscales and Cronbach's alpha values between 0.78 and 0.93. Good test-retest reliability was also found, and r values for subscales ranged from 0.62 to 0.99. The instrument proved to be a reliable, valid and sensitive measure in the study of mental adjustment of Portuguese end-of-life patients with cancer receiving palliative care. Nurses can use the Mini-MAC Scale in research and clinical practice in order to evaluate the mental adjustment of Portuguese end-of-life cancer patients receiving palliative care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Ultrasonic diagnosis and transurethral incision of ureterocele with hydronephrosis

    DEFF Research Database (Denmark)

    Waaddegaard, P; Miskowiak, J; Stage, P

    1991-01-01

    In a 65-year-old woman with right-sided loin pain, ultrasonography revealed a grossly dilated and obstructed right pyelogram due to a 50-mm ureterocele. After transurethral lateral incision of the ureterocele, there was complete recovery without vesicoureteric reflux. Ultrasonography is advantage...

  15. Histomorphological and immunofluorescence evaluation of clear corneal incisions after microcoaxial phacoemulsification with 2.2 mm and 1.8 mm systems.

    Science.gov (United States)

    Vasavada, Abhay R; Johar, Kaid; Praveen, Mamidipudi R; Vasavada, Viraj A; Arora, Anshul I

    2013-04-01

    To compare changes in the incision's histomorphology and denaturation of collagen I in rabbit eyes having microcoaxial phacoemulsification through 2.2 mm and 1.8 mm incision-compatible systems. Randomized experimental trial. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Thirty rabbit eyes were randomized into Group 1 (microcoaxial phacoemulsification through 2.2 mm incisions using Infiniti system [torsional ultrasound]) and Group 2 (microcoaxial phacoemulsification through 1.8 mm incisions using Stellaris system [longitudinal ultrasound]). Each group was then divided into 3 subgroups of 5 eyes each based on 1 of the 3 intervention options: phacoemulsification only, intraocular lens (IOL) insertion only, and phacoemulsification with IOL insertion. Left eyes were randomized for microcoaxial phacoemulsification, and right eyes were treated as controls. After phacoemulsification, eyes in Group 1 showed loss of epithelium at the roof of the incisions and Descemet membrane detachment at the floor of the incisions. These findings did not change after IOL insertion. After phacoemulsification, eyes in Group 2 showed loss of epithelium, but Descemet membrane remained attached. There was a longitudinal split in the incision's stroma in the direction of internal entry. The stromal damage increased after IOL implantation. Immunofluorescence studies showed no obvious irregularities in the arrangement of collagen I in either group. A dot blot analysis showed significant denaturation of collagen I in Group 2. The histomorphology of the 2.2 mm system incision showed localized Descemet membrane detachment and endothelial cell loss. The 1.8 mm system incision showed exaggerated stromal damage after IOL insertion. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Maximum atmosphere at the Mini Atomiades

    CERN Multimedia

    Rachel Bray, Atomiades organizer team

    2016-01-01

    CERN Clubs Coordination Committee and CERN Staff Association host the ASCERI Mini Atomiades June 2016.   The CERN team won the tennis tournament for the Mini Atomiades 2016. (Photo: Erwin Van Hove) Over 180 participants from 10 different European Scientific Research Institutes came together on the first weekend of June in Divonne-les-Bains to take part in the ASCERI Sport & Science Mini Atomiades. Sports men and women from Belgium, Germany, France, Hungary, Russia and Switzerland battled it out in four different tournaments for medals, cups and, above all, lots of fun. The four disciplines included football, golf, tennis and a 10km race. CERN was victorious in tennis, golf and the men's and women's 10km, and despite the CERN football team putting up an excellent fight against some very strong teams they came almost last (we cannot win everything, can we?). But CERN were the clear winners for team spirit, community and camaraderie, as confirmed by all the comp...

  17. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  18. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  19. Three-dimensional observations of the incisive canal and the surrounding bone using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Asaumi, Rieko; Kawai, Taisuke; Sato, Iwao; Yoshida, Shunji; Yosue, Takashi

    2010-01-01

    The shape of the anterior region of the maxilla is critical when planning implant treatment. The purpose of the present study was to assess the typical morphology of the incisive canal and surrounding bone. In total, 70 maxillae of Japanese dry skulls were used after being divided into dentate and edentulous groups. Cone-beam computed tomography (CBCT) images of the maxilla were acquired by using standardized methods. Using the anterior nasal spine as a reference point, the change in position was measured and analyzed statistically. Also, three-dimensional (3-D) images of the incisive canal were classified into five subsets: cylinder, groove, penetration, bifurcation at the superior portion, and bifurcation at the inferior portion. The quantity of alveolar bone in the incisor region was greatly reduced from the alveolar ridge and labial surface. Moreover, the vertical position of the incisive foramen was significantly (P<0.05) superior in the edentulous groups. Regarding the classification of maxillae by the 3-D shape of the incisive canal, many canals were cylindrical. Horizontal bone reduction from the labial side and vertical bone reduction from the alveolar crest were conspicuous; thus, the angle of the anterior alveolar bone changed after the loss of teeth. The incisive canal diameter in the edentulous group was larger than in the dentate group. The nondestructive assessment of the incisive canals and surrounding bone with CBCT showed two typical shapes for the presence or absence of the incisors. These findings indicate the importance of image diagnosis before esthetic restoration. (author)

  20. Water table and overbank flow frequency changes due to suburbanization-induced channel incision, Virginia Coastal Plain, USA

    Science.gov (United States)

    Hancock, G.; Mattell, N.; Christianson, E.; Wacksman, J.

    2004-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that incision has lowered floodplain water tables and decreased the overbank flow frequency, and suggest these changes impact vegetation distribution in a diverse, protected riparian habitat. The monitored stream is a tributary to the James River draining 1.3 km2, of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one m high knickpoint at a rate of 1-2 m/yr, primarily during high flow events. We installed 33 wells in six floodplain transects to assess water table elevations beneath the floodplain adjacent to the incising stream. To document the impacts of incision, two transects are located 30 and 50 m upstream of the knickpoint in unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream of the knickpoint in incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table response to storm events. Significant differences have been observed in the water table above and below the knickpoint. Above the knickpoint, the water table is relatively flat and is 0.2-0.4 m below the floodplain surface. Water table response to precipitation events is nearly immediate, with the water table rising to the floodplain surface in significant rainfall events. In the transect immediately downstream of the knickpoint, the water table possesses a steep gradient, rising from ~1 m below the floodplain at the stream to 0.3 m below the surface within 20 m. In the most downstream transects, the water table is relatively flat, but is one m below the floodplain surface, equivalent to the depth of incision generated by knickpoint passage. Upstream of the knickpoint, overbank flooding occurs

  1. Heterotopic ossification in abdominal incision : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Yoon Sik; Nam, Kung Sook; Hwang, Im Kyung; Kim, Heung Chul [College of Medicine, Hallym Univ., Chuncheon (Korea, Republic of)

    2001-08-01

    Heterotopic ossification in abdominal incision is a rare post-surgical sequala and a subtype of myositis ossificans traumatica. Recognition of this rare condition is important because it may be misinterpreted as a retained foreign body or incisional neoplastic recurrence. We report a case involving a 59-year-old man who presented with a palpable epigastric mass and pronounced fatigability.

  2. Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement.

    Science.gov (United States)

    Tavakoli, Reza; Leprince, Pascal; Gassmann, Max; Jamshidi, Peiman; Yamani, Nassrin; Amour, Julien; Lebreton, Guillaume

    2018-03-26

    Aortic valve stenosis has become the most prevalent valvular heart disease in developed countries, and is due to the aging of these populations. The incidence of the pathology increases with growing age after 65 years. Conventional surgical aortic valve replacement through median sternotomy has been the gold standard of patient care for symptomatic aortic valve stenosis. However, as the risk profile of patients worsens, other therapeutic strategies have been introduced in an attempt to maintain the excellent results obtained by the established surgical treatment. One of these approaches is represented by transcatheter aortic valve implantation. Although the outcomes of high-risk patients undergoing treatment for symptomatic aortic valve stenosis have improved with transcatheter aortic valve replacement, many patients with this condition remain candidates for surgical aortic valve replacement. In order to reduce the surgical trauma in patients who are candidates for surgical aortic valve replacement, minimally invasive approaches have garnered interest during the past decade. Since the introduction of right anterior thoracotomy for aortic valve replacement in 1993, right anterior mini-thoracotomy and upper hemi-sternotomy have become the predominant incisional approaches among cardiac surgeons performing minimal access aortic valve replacement. Beside the location of the incision, the arterial cannulation site represents the second major landmark of minimal access techniques for aortic valve replacement. The two most frequently used arterial cannulation sites include central aortic and peripheral femoral approaches. With the purpose of reducing surgical trauma in these patients, we have opted for a right anterior mini-thoracotomy approach with a central aortic cannulation site. This protocol describes in detail a technique for minimally invasive aortic valve replacement and provides recommendations for patient selection criteria, including cardiac computer

  3. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  4. Lateral Nail Fold Incision Technique for Venous Anastomosis in Fingertip Replantation.

    Science.gov (United States)

    Jeon, Byung-Joon; Yang, Jae-Won; Roh, Si Young; Ki, Sae Hwi; Lee, Dong Chul; Kim, Jin Soo

    2016-01-01

    Successful venous anastomosis is one of the most important factors in fingertip replantation. Volar veins in the fingertip course proximally in a random pattern, which makes it difficult to find out the exact locations. Although dorsal veins in the lateral nail fold have constant location and adequate diameter for anastomosis, they have been known as hard to dissect from the immobile subcutaneous tissue. The authors present a new lateral nail fold incision technique for venous anastomosis in the fingertip amputations. From February 2010 to October 2010, 9 replantations using the new incision and venous anastomosis technique were performed in 9 patients. The levels of amputations were from the nail base to half of the nail bed. After repairing the proper digital arteries, a skin incision was made along the junction between the lateral nail fold and nail bed. Careful dissection was performed to isolate the veins in the lateral nail fold. After evaluation of the suitability of the vessel, venous anastomosis was performed. Seven male and 2 female patients were enrolled in this study. Appropriate dorsal veins for anastomosis could be found in 8 of 9 patients. All the replanted stumps survived without venous congestion and following additional procedures. A sizable volar or dorsal vein could not be found in 1 patient. The salvage technique was required in this patient. Dorsal veins in the lateral nail fold can be found easily because of the constant anatomical location. The new incision on the lateral nail fold provides not only sufficient operative field for anastomosis but also additional opportunity of successful venous anastomosis in the selected cases. The authors, therefore, propose this technique as an effective method for an alternative venous anastomosis in the zone I replantation.

  5. Minimal Incision Scar-Less Open Umbilical Hernia Repair in Adults - Technical Aspects and Short Term Results

    Directory of Open Access Journals (Sweden)

    Sanoop Koshy Zachariah

    2014-09-01

    Full Text Available Background: There is no gold standard technique for umbilical hernia repair .Conventional open umbilical hernia repair often produces an undesirable scar. Laparoscopic umbilical hernia repair requires multiple incisions beyond the umbilicus, specialized equipments, and expensive tissue separating mesh. We describe our technique of open umbilical hernia repair utilizing a small incision. The technique was derived from our experience with single incision laparoscopy. We report the technical details and short term results. Methods: This is a retrospective analysis of the first 20 patients who underwent minimal incision scar-less open umbilical hernia repair, from June 2011 to February 2014. A single intra-umbilical curved incision was used to gain access to the hernia sac. Primary suture repair was performed for defects upto 2cm.Larger defects were repaired using an onlay mesh. In patients with a BMI of 30 kg/m2 or greater, onlay mesh hernioplasty was performed irrespective of the defect size.Results: A total of 20 patients, 12 males and 8 females underwent the procedure. Mean age was 50 (range 29 - 82 years. Mean BMI was 26.27 (range 20. -33.1 kg/m2. Average size of the incision was 1.96 range (1.5 to 2.5 cm. Mesh hernioplasty was done in 9 patients. 11 patients underwent primary suture repair alone. There were no postoperative complications associated with his technique. Average post operative length of hospital stay was 3.9 (range 2-10 days. Mean follow-up was 29.94 months, (2 weeks to 2.78 years. On follow up there was no externally visible scar in any of the patients. There were no recurrences on final follow up. Conclusion: This technique provides a similar cosmetic effect as obtained from single port laparoscopy. It is easy to perform safe, offers good cosmesis, does not require incisions beyond the umbilicus and cost effective, with encouraging results on short term follow up. Further research is needed to assess the true potential of the

  6. Chemical weathering as a mechanism for the climatic control of bedrock river incision

    Science.gov (United States)

    Murphy, Brendan P.; Johnson, Joel P. L.; Gasparini, Nicole M.; Sklar, Leonard S.

    2016-04-01

    Feedbacks between climate, erosion and tectonics influence the rates of chemical weathering reactions, which can consume atmospheric CO2 and modulate global climate. However, quantitative predictions for the coupling of these feedbacks are limited because the specific mechanisms by which climate controls erosion are poorly understood. Here we show that climate-dependent chemical weathering controls the erodibility of bedrock-floored rivers across a rainfall gradient on the Big Island of Hawai‘i. Field data demonstrate that the physical strength of bedrock in streambeds varies with the degree of chemical weathering, which increases systematically with local rainfall rate. We find that incorporating the quantified relationships between local rainfall and erodibility into a commonly used river incision model is necessary to predict the rates and patterns of downcutting of these rivers. In contrast to using only precipitation-dependent river discharge to explain the climatic control of bedrock river incision, the mechanism of chemical weathering can explain strong coupling between local climate and river incision.

  7. Effect of Recycling Protocol on Mechanical Strength of Used Mini-Implants

    OpenAIRE

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 follo...

  8. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    Science.gov (United States)

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  9. A method of posterior fossa dural incision to minimize hemorrhage from the occipital sinus: the "mosquito" method.

    Science.gov (United States)

    Lee, Hee Chang; Lee, Ji Yeoun; Ryu, Seul Ki; Lim, Jang Mi; Chong, Sangjoon; Phi, Ji Hoon; Kim, Seung-Ki; Wang, Kyu-Chang

    2016-12-01

    The posterior fossa dural opening requires the ligation of the occipital sinus to gain successful exposure. However, there could be a prominent occipital sinus which is functioning as the main drainage route and is harboring the risk of unpredictable massive hemorrhage during the dural opening. We introduce a safe method of posterior fossa dural incision to minimize hemorrhage from the occipital sinus using four curved hemostat clamps. For the dural incision at the midline part of the posterior cranial fossa, we used four curved hemostat clamps to occlude the prominent occipital sinus: one pair of clamps at the proximal part and the other pair at the distal part to occlude the occipital sinus. Dural incision was made between the two pairs of the curved hemostat clamps. By clamping of the sinus, it allows observation of possible brain swelling after occlusion of the occipital sinus as well as minimizes hemorrhage during incision of the midline dura of the posterior fossa. This method allows observation of brain swelling after occipital sinus occlusion and is an easy and safe incision of the midline dura minimizing hemorrhage in selected cases with a prominent occipital sinus.

  10. Advantages of the modified double ring areolar incision over the traditional areolar incision in multicentric breast fibroadenoma surgery.

    Science.gov (United States)

    Zhang, Mingliang; Shen, Gongjin; Zhang, Song; Cui, Zhen; Qian, Jun

    2017-09-01

    This study was conducted to investigate the clinical advantages of modified double ring areola incision (MDRAI) compared to ordinary areola incision (OAI) in multicentric breast fibroadenoma in women. Sixty cases of multicentric benign breast tumor were recruited from the First Affiliated Hospital of Bengbu Medical College from January to December 2016. The cases were divided into two groups according to surgical approach: MDRAI (n = 20) and OAI (n = 40). The operation duration, intraoperative blood loss, drainage time, and postoperative recurrence rate in the first six months were compared. The mean age and tumor locations were not statistically different between the groups (P > 0.05). However, more lesions and larger tumor diameter were found in the MDRAI group than in the OAI group, with statistical difference (P  0.05). However, the intraoperative blood loss was statistically different between the two groups (P < 0.05). All 60 cases received six months of follow-up. Eight recurrent cases were found in the OAI group, but none in the MDRAI group. The recurrence rate was significantly different (χ 2  = 4.62, P < 0.05). Compared with OAI, MDRAI offers greater advantages in the aspects of blood loss and recurrence for the treatment of breast benign tumor, especially for multicentric larger lesions. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  11. Mini-mental Parkinson (MMP) as a dementia screening test: comparison with the Mini-Mental State Examination (MMSE).

    Science.gov (United States)

    Larner, Andrew J

    2012-07-01

    As populations age, screening instruments for cognitive impairment and dementia will become of increasing importance in clinical practice. Mini-Mental Parkinson (MMP), a derivative of the Mini-Mental State Examination (MMSE), was originally described as a cognitive screening instrument for use in Parkinson's disease. Its item content addresses some of the acknowledged shortcomings of the MMSE. Pragmatic use of MMP in general cognitive clinics has not previously been examined. To compare the performance of two scales, Mini-Mental Parkinson (MMP) and the Mini-Mental State Examination (MMSE), as cognitive screening instruments for dementia in a memory clinic population. MMP was administered prospectively to 201 consecutive new patient referrals independent of other tests used to establish dementia diagnosis according to standard diagnostic criteria (DSM-IV). Diagnostic utility of MMP for dementia was measured and compared with MMSE. MMP proved easy to use and acceptable to patients. Optimal test accuracy (0.86) was at MMP cutoff of ≤ 17/32, with sensitivity 0.51, specificity 0.97, positive predictive value 0.83, negative predictive value 0.87, and area under Receiver Operating Characteristic curve 0.89. Using a higher cutoff (≤ 29/32), MMP sensitivity was 1.00 with specificity 0.70. MMP scores correlated with MMSE (r = 0.93) and diagnostic agreement was high (κ = 0.85). MMP is a useful screening instrument in the memory clinic setting, with patients who fall below the designated cutoff requiring further investigation to ascertain a cause for their cognitive impairment.

  12. Seismic evidence of glacial-age river incision into the Tahaa barrier reef, French Polynesia

    Science.gov (United States)

    Toomey, Michael; Woodruff, Jonathan D.; Ashton, Andrew D.; Perron, J. Taylor

    2016-01-01

    Rivers have long been recognized for their ability to shape reef-bound volcanic islands. On the time-scale of glacial–interglacial sea-level cycles, fluvial incision of exposed barrier reef lagoons may compete with constructional coral growth to shape the coastal geomorphology of ocean islands. However, overprinting of Pleistocene landscapes by Holocene erosion or sedimentation has largely obscured the role lowstand river incision may have played in developing the deep lagoons typical of modern barrier reefs. Here we use high-resolution seismic imagery and core stratigraphy to examine how erosion and/or deposition by upland drainage networks has shaped coastal morphology on Tahaa, a barrier reef-bound island located along the Society Islands hotspot chain in French Polynesia. At Tahaa, we find that many channels, incised into the lagoon floor during Pleistocene sea-level lowstands, are located near the mouths of upstream terrestrial drainages. Steeper antecedent topography appears to have enhanced lowstand fluvial erosion along Tahaa's southwestern coast and maintained a deep pass. During highstands, upland drainages appear to contribute little sediment to refilling accommodation space in the lagoon. Rather, the flushing of fine carbonate sediment out of incised fluvial channels by storms and currents appears to have limited lagoonal infilling and further reinforced development of deep barrier reef lagoons during periods of highstand submersion.

  13. The Problem of the Pannus: Physician Preference Survey and a Review of the Literature on Cesarean Skin Incision in Morbidly Obese Women.

    Science.gov (United States)

    Smid, Marcela C; Smiley, Sarah G; Schulkin, Jay; Stamilio, David M; Edwards, Rodney K; Stuebe, Alison M

    2016-04-01

    This study aims to determine preferences of a nationally representative sample of obstetrician/gynecologists (OB/GYNs) regarding cesarean delivery (CD) incision practices for women with morbid obesity (body mass index ≥ 40 kg/m(2)). We conducted an online survey using the American College of Obstetricians and Gynecologists database. We compared physician demographics, practice characteristics, and CD incision type preference. After exclusion of ineligible participants, 247 OB/GYNs completed the survey (42% response rate). In nonemergency CD of morbidly obese women, 84% of physicians preferred a Pfannenstiel skin incision (67% preferring taping the pannus; 17% without taping the pannus). In emergency CD, 66% preferred a Pfannenstiel incision (46% without taping the pannus; 20% with taping the pannus) and 20% a vertical incision. For both emergency and nonemergency CD, there was no difference in incision type preferences by provider years in practice, practice scope, or number of CD performed each year. Given the preference of a Pfannenstiel incision with taping the pannus during CD of morbidly obese women, further investigation is needed to assess the risks and benefits of this incision and the practice of elevating the pannus. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...... of communicative and cooperative skills and 2) whether mini-CEX would provide reproducible data. MATERIAL AND METHODS: Twenty-one residents were evaluated by mini-CEX by trained observers. Seventeen residents had at least two observations within a short period of time and these data were used to estimate the mini...

  15. Impact of selective pituitary gland incision or resection on hormonal function after adenoma or cyst resection.

    Science.gov (United States)

    Barkhoudarian, Garni; Cutler, Aaron R; Yost, Sam; Lobo, Bjorn; Eisenberg, Amalia; Kelly, Daniel F

    2015-12-01

    With the resection of pituitary lesions, the anterior pituitary gland often obstructs transsphenoidal access to the lesion. In such cases, a gland incision and/or partial gland resection may be required to obtain adequate exposure. We investigate this technique and determine the associated risk of post-operative hypopituitarism. All patients who underwent surgical resection of a pituitary adenoma or Rathke cleft cyst (RCC) between July 2007 and January 2013 were analyzed for pre- and post-operative hormone function. The cohort of patients with gland incision/resection were compared to a case-matched control cohort of pituitary surgery patients. Total hypophysectomy patients were excluded from outcome analysis. Of 372 operations over this period, an anterior pituitary gland incision or partial gland resection was performed in 79 cases (21.2 %). These include 53 gland incisions, 12 partial hemi-hypophysectomies and 14 resections of thinned/attenuated anterior gland. Diagnoses included 64 adenomas and 15 RCCs. New permanent hypopituitarism occurred in three patients (3.8 %), including permanent DI (3) and growth hormone deficiency (1). There was no significant difference in the rate of worsening gland dysfunction nor gain of function. Compared to a control cohort, there was a significantly lower incidence of transient DI (1.25 vs. 11.1 %, p = 0.009) but no significant difference in permanent DI (3.8 vs. 4.0 %) in the gland incision group. Selective gland incisions and gland resections were performed in over 20 % of our cases. This technique appears to minimize traction on compressed normal pituitary gland during removal of large lesions and facilitates better visualization and removal of cysts, microadenomas and macroadenomas.

  16. Estudo comparativo entre a miniesternotomia em "L" invertido e esternotomia longitudinal total na correção cirúrgica da comunicação interatrial Comparative study between inverted "L" mini-sternotomy and complete sternotomy for the surgical treatment of the atrial septal defect (ASD

    Directory of Open Access Journals (Sweden)

    Luiz Cláudio Nery Sampaio

    2005-03-01

    Full Text Available OBJETIVO: Comparar os resultados obtidos entre duas vias de acesso cirúrgico em pacientes submetidos à correção cirúrgica de comunicação interatrial (CIA. MÉTODO: Foram distribuídos 20 pacientes, com média de idade de 24,1±14,2 anos, em dois grupos. No grupo A, 10 pacientes (80% do sexo feminino, com média de idade de 20,9 ± 12,0 anos foram submetidos à correção da CIA por meio de uma esternotomia longitudinal total. No grupo B, 10 pacientes (80% do sexo feminino, com média de idade de 27,4 ± 16,1 anos foram submetidos à correção da CIA através de miniesternotomia em "L" invertido. Foi considerado significativo p OBJECTIVE: To compare the results obtained from two distinct surgical approaches in patients undergoing surgical correction of an atrial septal defect (ASD. METHOD: The study series consisted of 20 patients, with a mean age of 24.1±14.2 years, distributed in two groups. In group A, 10 patients (80% female, with a mean age of 20.9±12.0 years underwent surgical correction of ASD through a complete sternotomy. In group B, 10 patients (80% female, with mean age of 27.4±16.1 years, were operated through an inverted "L" mini-sternotomy. A p-value < 0.05 was considered statistically significant. RESULTS: There was no statistical significance for demographics variables, duration of surgery, cardiopulmonary bypass time, clamping time, amount of cardioplegia administered, thoracic drainage, ICU stay, duration of mechanical ventilatory support, amount of blood and its components transfused, arrhythmia or pacemaker usage. There was statistical significance (p= 0.00001 between incision size performed by complete sternotomy (group A and inverted "L" mini-sternotomy (group B, with mean incision size of 15.7±0.8 e 6.8±0.6cm, respectively. There was a difference in the mean hospital stay between the groups but without statistical significance (7.5±1.6 days in group A and 6.4±1.3 days in group B, with a p-value = 0.12. There

  17. Incision of the heart during meat inspection of fattening pigs - A risk-profile approach.

    Science.gov (United States)

    Leps, J; Fries, R

    2009-01-01

    Meat inspection in the EU is based on Regulation (EC) 854/2004. Accordingly a risk based meat inspection should be implemented. In this paper, the incision of the heart in pig meat inspection is discussed with respect to efficacy. The incision especially can reveal the presence of endocarditis. Here, Erysipelothrixrhusiopathiae (E. rhusiopathiae) and/or Streptococcussuis (S. suis) are of particular concern. Both agents are regarded to be zoonotic agents. There is some evidence for infection of humans via an alimentary pathway. Hence, the occurrence of E. rhusiopathiae and S. suis is a concern of public health (PH) as well as veterinary public health (VPH). However, other measures, including on-farm disease prevention and diagnosis, seem to be more important for food safety. It is concluded that the incision and inspection of the heart is not justifiable with respect to PH aspects.

  18. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    International Nuclear Information System (INIS)

    Hantao Ji

    2004-01-01

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers

  19. Mini-conference and Related Sessions on Laboratory Plasma Astrophysics

    Energy Technology Data Exchange (ETDEWEB)

    Hantao Ji

    2004-02-27

    This paper provides a summary of some major physics issues and future perspectives discussed in the Mini-Conference on Laboratory Plasma Astrophysics. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2003 Annual Meeting (October 27-31, 2003). Also included are brief summaries of selected talks on the same topic presented at two invited paper sessions (including a tutorial) and two contributed focus oral sessions, which were organized in coordination with the Mini-Conference by the same organizers.

  20. Screening for Dementia in Older Adults: Comparison of Mini-Mental State Examination, Mini-Cog, Clock Drawing Test and AD8.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin

    2016-01-01

    This study was conducted to estimate screening performance of dementia screening tools including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) for older adults. 2015 participants aged 65 years or more in eastern China were enrolled. 4 screening tests were administered and scored by specifically trained psychiatrists. We used data from two-by-two tables to calculate the sensitivity, specificity, and positive and negative predictive values (PPV/NPV). Our study showed that dementia was highly prevalent among elderly in Zhejiang province. The Mini-Cog, with excellent screening characteristics and spending less time, could be considered to be used as a screening tool among communities to help to diagnose dementia early.

  1. No-Drain Single Incision Liposuction Pull-Through Technique for Gynecomastia.

    Science.gov (United States)

    Khalil, Ashraf A; Ibrahim, Amr; Afifi, Ahmed M

    2017-04-01

    Several different methods have been proposed for treatment of gynecomastia, depending on the amount of breast enlargement and skin redundancy. The liposuction pull-through technique has been proposed as an efficacious treatment for many gynecomastia cases. This work aims to study the outcome of this technique when applied as an outpatient procedure, without the use of drains and through a single incision. Fifty-two patients with bilateral gynecomastia without significant skin excess were included in this study. The liposuction pull-through technique was performed through a single incision just above the inframammary fold and without the use of drains. Patients were followed up for 6 months. The proposed technique was able to treat the gynecomastia in all patients, with a revision rate of 1.9% to remove residual glandular tissues. There were no seromas, hematomas, nipple distortion, permanent affection of nipple sensation or wound healing problems. The liposuction pull-through technique is an effective treatment for gynecomastia without significant skin redundancy. It combines the benefits of the direct excision of glandular tissues, with the minimally invasive nature of liposuction. Performing the procedure through a single incision without the use of drains and without general anesthesia is a safe alternative. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .

  2. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    Science.gov (United States)

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  3. Systemic levels of metallic ions released from orthodontic mini-implants.

    Science.gov (United States)

    de Morais, Liliane Siqueira; Serra, Glaucio Guimarães; Albuquerque Palermo, Elisabete Fernandes; Andrade, Leonardo Rodrigues; Müller, Carlos Alberto; Meyers, Marc André; Elias, Carlos Nelson

    2009-04-01

    Orthodontic mini-implants are a potential source of metallic ions to the human body because of the corrosion of titanium (Ti) alloy in body fluids. The purpose of this study was to gauge the concentration of Ti, aluminum (Al), and vanadium (V), as a function of time, in the kidneys, livers, and lungs of rabbits that had Ti-6Al-4V alloy orthodontic mini-implants placed in their tibia. Twenty-three New Zealand rabbits were randomly divided into 4 groups: control, 1 week, 4 weeks, and 12 weeks. Four orthodontic mini-implants were placed in the left proximal tibia of 18 rabbits. Five control rabbits had no orthodontic mini-implants. After 1, 4, and 12 weeks, the rabbits were killed, and the selected tissues were extracted and prepared for analysis by graphite furnace atomic absorption spectrophotometry. Low amounts of Ti, Al, and V were detectable in the 1-week, 4-weeks, and 12-weeks groups, confirming that release of these metals from the mini-implants occurs, with diffusion and accumulation in remote organs. Despite the tendency of ion release when using the Ti alloy as orthodontic mini-implants, the amounts of metals detected were significantly below the average intake of these elements through food and drink and did not reach toxic concentrations.

  4. Triple pelvic osteotomy in Legg-Calve-Perthes disease using a single anterolateral incision: a 4-year review.

    LENUS (Irish Health Repository)

    Conroy, Eimear

    2010-07-01

    Femoral head incongruency at skeletal maturity is associated with the development of osteoarthritis in early adulthood. Containment of the femoral head provides a larger surface area for remodelling of the collapsed femoral head and the development of spherical congruency. Triple pelvic osteotomy has a role to play in Legg-Calve-Perthes\\' disease by improving femoral head containment and preventing subluxation. This is traditionally a two-incision approach with significant associated morbidity. In our unit we perform triple osteotomies through a single anterolateral incision. To retrospectively review the clinical and radiographic outcome of children who had triple osteotomies performed through a single incision over a 4-year period. In our unit from 2003 to 2006 we performed eight triple osteotomies through a single incision in children aged between 6 and 12 years with Legg-Calve-Perthes\\' disease. The procedure was performed through a single anterolateral incision made beneath the middle of the iliac crest and carried forward according to Salter\\'s osteotomy. Image intensification was used to confirm iliac, pubic and ischial cuts. After performing a standard Salter\\'s osteotomy the acetabular fragment was free to rotate anteriorly and laterally. None of the children were casted and all were allowed immediate mobilization nonweight bearing with crutches for 6 weeks. Clinical results and hip function were measured preoperatively and postoperatively using the modified Harris hip score. The average length of hospital stay was 4.7 days. None of the children had a nonunion. The centre edge angle of Wiberg was measured on all preoperative and postoperative anteroposterior pelvic radiographs. In all our patients there was an improvement in the centre edge angle of Wiberg and in the modified Harris hip score. The preoperative modified Harris hip scores ranged from 38 to 60 and postoperatively ranged from 77 to 92. The preoperative centre edge angle of Wiberg ranged

  5. Measuring mental health in the clinical setting: what is important to service users? The Mini-Service user Recovery Evaluation scale (Mini-SeRvE).

    Science.gov (United States)

    Barber, Joanna M; Parsons, Helen; Wilson, Carol A; Cook, Christopher C H

    2017-12-01

    Since 2001, a policy of positive mental health recovery has been promoted in the UK, with service user involvement. This has not been easy to implement in the clinical setting. To develop and validate a brief self-report, service user-designed, outcome measure (Mini-SeRvE), for clinical use, including spiritual and religious issues. From the previously developed Service user Recovery Evaluation scale (SeRvE), 15 questions were selected for Mini-SeRvE which was self-completed by 207 people; 100 service users and, for comparison, 107 staff. Results were analysed using SPSS software (SPSS Inc., Chicago, IL). Mini-SeRvE is reliable, Cronbach's alpha 0.852. Correlation with another recovery scale, Mental Health Recovery Measure, was high, r = 0.819. Three reliable subscales emerged; existential well-being (EWB), mental ill-being (MIB) and religious well-being (RWB). Scores of the EWB and MIB subscales were higher for staff, consistent with higher mental well-being. Religious well-being scores were higher in service users, who also rated religion as more important to them. Mini-SeRvE is a valid measure of service user recovery. The importance of religion/spiritual belief for our users is highlighted, this being reflected in the subject matter of Mini-SeRvE. Mini-SeRvE assessments could show individual priorities, evaluate therapy and aid clinical decision-making.

  6. Taman Mini Indonesia Indah sebagai Bagian dari Fenomena Taman Budaya Dunia

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Wulandari

    2012-10-01

    Full Text Available Cultural display in an open space or known as cultural parks appears rapidly as a worldwide phenomenon. From the European model which has a strong educational value, to the Asian parks which not only has educational function, but also has recreational purposes. So many types and characteristics of these parks, researches give them different names, thodse are Open-air museums, Ethnographic Theme Parks or even Theme Parks. Taman Mini Indonesia Indah as a part of this phenomenon was built first and foremost for educational purposes, therefore Taman Mini can be considered as an open-air museum. However, since Taman Mini also has recreational purposes, others can argue that Taman Mini is a theme park. Qualitative method will be used for this research, through observation to Taman Mini Indonesia Indah, followed by extensive literature review. With these data along with a table which points out the distinction between museum and theme parks. It can  be concluded that Taman Mini is a Theme Park.   

  7. Refining MARGINS Mini-Lessons Using Classroom Observations

    Science.gov (United States)

    Iverson, E. A.; Manduca, C. A.; McDaris, J. R.; Lee, S.

    2009-12-01

    One of the challenges that we face in developing teaching materials or activities from research findings is testing the materials to determine that they work as intended. Traditionally faculty develop material for their own class, notice what worked and didn’t, and improve them the next year. However, as we move to a community process of creating and sharing teaching materials, a community-based process for testing materials is appropriate. The MARGINS project has piloted such a process for testing teaching materials and activities developed as part of its mini-lesson project (http://serc.carleton.edu/margins/index.html). Building on prior work developing mechanisms for community review of teaching resources (e.g. Kastens, 2002; Hancock and Manduca, 2005; Mayhew and Hall, 2007), the MARGINS evaluation team developed a structured classroom observation protocol. The goals of field testing are to a) gather structured, consistent feedback for the lesson authors based on classroom use; b) guide reviewers of these lessons to reflect on research-based educational practice as a framework for their comments; c) collect information on the data and observations that the reviewer used to underpin their review; d) determine which mini-lessons are ready to be made widely available on the website. The protocol guides faculty observations on why they used the activity, the effectiveness of the activity in their classroom, the success of the activity in leading to the desired learning, and what other faculty need to successfully use the activity. Available online (http://serc.carleton.edu/margins/protocol.html), the protocol can be downloaded and completed during instruction with the activity. In order to encourage review of mini-lessons using the protocol, a workshop focused on review and revision of activities was held in May 2009. In preparation for the workshop, 13 of the 28 participants chose to field test a mini-lesson prior to the workshop and reported that they found this

  8. Two Late Pleistocene climate-driven incision/aggradation rhythms in the middle Dnieper River basin, west-central Russian Plain

    Science.gov (United States)

    Panin, Andrei; Adamiec, Grzegorz; Buylaert, Jan-Pieter; Matlakhova, Ekaterina; Moska, Piotr; Novenko, Elena

    2017-06-01

    In valleys of the River Seim and its tributaries in the middle Dnieper basin (west-central Russian Plain), two low terraces (T1, 10-16 m, and T0, 5-7 m above the river) and a floodplain (2-4 m) with characteristic large and small palaeochannels exist. A range of field and laboratory techniques was applied and ∼30 new numerical ages (OSL and 14C dates) were obtained to establish a chronology of incision and aggradation events that resulted in the current valley morphology. Two full incision/aggradation rhythms and one additional aggradation phase from the previous rhythm were recognized in the Late Pleistocene - Holocene climate cycle. The following events were detected. (1) Late MIS 5 - early MIS 4: aggradation of Terrace T1 following the deep incision at the end of MIS 6. (2) Late MIS 4 (40-30 ka): incision into Terrace T1 below the present-day river, formation of the main scarp in the bottom of the valley between Terrace T1 and Terrace T0/Floodplain levels. (3) MIS 2: aggradation of Terrace T0, lateral migrations of a shallow braided channel located few meters above the present-day river since ∼25 ka through the LGM. (4) 18-13 ka: incision into Terrace T0 below the modern river. Multiple-thread channels concentrated in a single flow that at some places formed large meanders. In the period 15-13 ka, high floods that rose above the present-day floods left large levees and overbank loams on Terrace T0. (5) Younger Dryas - Holocene transition: aggradation up to the modern channel level, transformation of large Late Glacial to small Holocene meanders. The established incision/aggradation rhythms are believed to be manifested over the Central Russian Plain outside the influence of ice sheets in the north and base level changes in the south. The two-phase deepening of the valley occurred in the last quarter of the last glacial epoch but can not be attributed directly to the glacial-interglacial transition. Both the detected incision events correspond to relatively

  9. In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomography.

    Science.gov (United States)

    Torres, Luis F; Saez-Espinola, Fidelia; Colina, Juner M; Retchkiman, Myriam; Patel, Milan R; Agurto, Ricardo; Garcia, Gerardo; Diaz, Jose L; Huang, David; Schanzlin, David J; Chayet, Arturo S

    2006-11-01

    To analyze in vivo the architecture of clear corneal incisions (CCIs) for phacoemulsification using optical coherence tomography (OCT). Anterior Segment Department, Asociacion Para Evitar la Ceguera en Mexico, Hospital Dr Luis Sanchez Bulnes, Mexico. A prospective masked study analyzed 20 unsutured CCIs placed superiorly and created in a uniplanar fashion with a 3.2 mm slit-angled metal keratome. All wounds were evaluated with a retinal OCT model 1, 3, and 30 days postoperatively. Intraocular pressure (IOP) and incision leakage were checked. The architecture was described according to the angle of incidence, apposition of the epithelial and endothelial margins, and wound sealing. No leakage was detected. The angle varied from 33 to 85 degrees; angles greater than 75 degrees were done by a surgeon in training. Wound apposition at the epithelial margin was achieved in all cases. In contrast, imperfect apposition of the endothelial margin was seen in 45% of incisions on day 1 and in 15% on day 30. Incomplete sealing of the wound was seen by OCT in 25% of cases at 24 hours and persisted in 10% of all cases at 1 month. This gaping occurred on the endothelial side and never translated to the epithelial margin. No statistical correlation was found between gaping and the angle of the incision, IOP variations, or surgeon experience. Although in vivo CCIs caused minor anatomic imperfections, they were clinically stable independent of incision angle, IOP variation, and surgeon experience. Incision stability may be related to careful wound construction, epithelial viability, stromal edema, and efficient endothelial pumping.

  10. Quantitative analysis of the relationship between maxillary incisors and the incisive canal by cone-beam computed tomography in an adult Japanese population

    Directory of Open Access Journals (Sweden)

    Tomonari Matsumura

    2017-08-01

    Full Text Available Abstract Background In setting goals for orthodontic treatment, determining the morphologies of the alveolar bone and maxillary incisor root is important for avoiding root resorption, dehiscence, and fenestration. This study aimed to analyze the configurational relationships among maxillary incisors, the alveolar border, and the incisive canal by cone-beam computed tomography (CBCT. Methods Cone-beam CT images of 93 orthodontic patients were evaluated for length of the incisive canal (L; angles between the palatal plane and the maxillary alveolar border (θ1, the incisive canal (θ2, and maxillary incisor (θ3; distance from the left maxillary incisor to the incisive canal (D; and cross-sectional areas of the incisive canal (CSAs at three vertical levels. Comparison of variables between male and female patients was performed with the two-sample t test. Correlations between parameters were examined by Pearson’s correlation analysis and Bonferroni correction for multiple comparisons. Results Male patients exhibited significantly greater values of L than female patients. There were significant positive correlations between θ1 and θ2, θ2 and θ3, and θ3 and θ1. While the value of D was the lowest at the oral opening, that of the cross-sectional area of the incisive canal (CSA was the greatest at the incisal root apex. Conclusions This study demonstrated that the incisive canal had large inter-individual variability, and the proximity between the incisive canal and the incisal root could not be precisely predicted by the conventional cephalograms. Therefore, pre-treatment CBCT examination should be recommended when a large amount of maxillary anterior retraction and/or intrusion is planned in orthodontic diagnosis.

  11. A mini-microscope for in situ monitoring of cells.

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R; Hamilton, Geraldine A; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E; Khademhosseini, Ali

    2012-10-21

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost.

  12. Complete overdentures retained by mini implants: A systematic review.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Júnior, Joel Ferreira Santiago; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    2017-02-01

    The purpose of this systematic review was to evaluate the use of mini implants to retain complete overdentures in terms of survival rates of mini implants, marginal bone loss, satisfaction, and quality of life. This report followed the PRISMA Statement and PICO question. This review has been registered at PROSPERO under the number CRD42016036141. Two independent reviewers performed a comprehensive search of studies published until September 2016 and listed in the PubMed/MEDLINE, Embase, and The Cochrane Library databases. The focused question was: is the use of mini implants feasible for prosthodontic rehabilitation with complete overdentures? The 24 studies selected for review evaluated 1273 patients whose mean age was 65.93 years; these patients had received 2494 mini implants and 386 standard implants for retaining overdenture prosthesis. The mean follow-up time was 2.48 years (range: 1-7 years). There was a higher survival rate of mini implants (92.32%). More frequent failures for maxillary (31.71%) compared with mandibular arches (4.89%). The majority of studies revealed marginal bone loss values similar to those of standard implants (overdenture prosthesis is considered an alternative treatment when standard treatment is not possible, since it presents high survival rates, acceptable marginal bone loss, and improvements in variables related to satisfaction and quality of life. Based on the results of this study, the use of a minimum 4 and 6 mini implants can be considered a satisfactory treatment option for rehabilitation of the mandibular and maxillary arches respectively with a complete overdenture. Copyright © 2016. Published by Elsevier Ltd.

  13. Mini-implantes ortodônticos como auxiliares da fase de retração anterior Orthodontic mini-implants assisting the anterior retraction phase

    Directory of Open Access Journals (Sweden)

    Carlo Marassi

    2008-10-01

    Full Text Available INTRODUÇÃO: os mini-implantes ortodônticos se estabeleceram como um importante método de ancoragem e vêm auxiliando os ortodontistas nas várias etapas do tratamento ortodôntico, eliminando, em grande parte, a necessidade de colaboração dos pacientes e tornando os resultados mais previsíveis. OBJETIVO: este artigo descreve os principais aspectos do uso dos mini-implantes como auxiliares da fase de retração anterior, trazendo considerações sobre suas indicações, quantidade de movimentação dos dentes anteriores, os vetores de força de retração, o controle vertical, o posicionamento dos mini-implantes, os tipos de apoio na região anterior e a força a ser utilizada. São citados os sítios de instalação mais usados para a retração anterior e abordados fatores que deverão ser controlados durante o fechamento de espaço. Por fim, são citadas algumas considerações clínicas sobre o uso dos mini-implantes nessa importante fase do tratamento ortodôntico.INTRODUCTION: The use of orthodontic mini-implants has settled as an important anchorage method and is aiding the orthodontists in the several stages of the treatment, largely eliminating the need of patients' compliance, and turning the results more predictable. AIM: This article describes the main aspects of the use of mini-implants as auxiliaries on the retraction phase of the anterior teeth, bringing considerations about their indications, amount of movement of the anterior teeth, the vectors of retraction force, the vertical control and evaluation of the incisors vestibulolingual tipping, the positioning of the mini-implants, the support types in the anterior area and the force to be applied. The placement sites best used for the anterior retraction are mentioned, and the factors that should be controlled during the space closure are approached. Lastly, some clinical considerations on the use of mini-implants in such important phase of the orthodontic treatment are

  14. Cervical and incisal marginal discrepancy in ceramic laminate veneering materials: A SEM analysis

    Directory of Open Access Journals (Sweden)

    Hemalatha Ranganathan

    2017-01-01

    Full Text Available Context: Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application. Aims: This study aimed to evaluate the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials. Settings and Design: This was an experimental, single-blinded, in vitro trial. Subjects and Methods: Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope. Statistical Analysis Used: ANOVA and post hoc Tukey honest significant difference (HSD tests were used for statistical analysis. Results: The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and post hoc Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored F = 243.408, P < 0.001 and F = 180.844, P < 0.001, respectively. Conclusion: This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups.

  15. The Mini-Cog versus the Mini-Mental State Examination and the Clock Drawing Test in daily clinical practice: screening value in a German Memory Clinic.

    Science.gov (United States)

    Milian, Monika; Leiherr, Anna-Maria; Straten, Guido; Müller, Stephan; Leyhe, Thomas; Eschweiler, Gerhard W

    2012-05-01

    The aim of this study was to compare the screening value of the Mini-Cog, Clock Drawing Test (CDT), Mini-Mental State Examination (MMSE) and the algorithm MMSE and/or CDT to separate elderly people with dementia from healthy depending on test time, type and severity of dementia, and demographic variables in a German Memory Clinic. Data from a heterogeneous patient sample and healthy participants (n = 502) were retrospectively analyzed. Of the 438 patients with dementia, 49.1% of the dementia diagnoses were Alzheimer's dementia and 50.9% were non-Alzheimer's dementia. Sixty-four participants were classified as cognitively unimpaired. The CDT and an extraction of the 3-item recall of the MMSE were used to constitute the Mini-Cog algorithm. Overall, the Mini-Cog showed significantly higher discriminatory power (86.8%) than the MMSE (72.6% at a cut-off ≤ 24 and 79.2% at ≤ 25, respectively) and CDT (78.1%) (each p 0.05). The specificity of the Mini-Cog (100.0%) was similar to that of the MMSE (100.0% for both cut-offs) and CDT (96.9%) (p = 0.154). For all age and educational groups the Mini-Cog outmatched the CDT and MMSE, and was less affected by education than MMSE and less susceptible for the dementia stage than the CDT. The Mini-Cog proved to have superior discriminatory power than either CDT or MMSE and is demonstrated to be a valid "short" screening instrument taking 3 to 4 minutes to administer in the geriatric setting.

  16. Relationship between peri-incisional dysesthesia and the vertical and oblique incisions on the hamstrings harvest in anterior cruciate ligament reconstruction

    Directory of Open Access Journals (Sweden)

    Marcos Laube Leite

    Full Text Available ABSTRACT OBJECTIVE: To compare the incidence of peri-incisional dysesthesia according to the skin incision technique for hamstring tendon graft harvest in anterior cruciate ligament reconstruction. METHODS: Thirty-three patients with ACL rupture were separated in two groups: group 1, with 19 patients submitted to the oblique skin incision to access the hamstrings and group 2-14 patients operated by vertical skin incision technique. The selected patients were assessed after surgery. Demographic data and prevalence of dysesthesia was measured by digital pressure around the skin incision and classified according to the Highet scale. RESULTS: The total rate of dysesthesia was 42% (14 patients. Five patients (26% on the oblique incision group reported dysesthesia symptoms. On the group submitted to the vertical incision technique, the involvement was 64% (nine patients. On the 33 knees evaluated, the superior lateral area was the most affected skin region, while the superior medial and inferior medial regions were affected in only one patient (7.1%. No statistical differences between both groups were observed regarding patients' weight, age, and height¸ as well as skin incision length. CONCLUSION: Patients who underwent reconstruction of the anterior cruciate ligament using the oblique access technique had five times lower incidence of peri-incisional dysesthesia when compared with those in whom the vertical access technique was used.

  17. [Is there a relation between mammaplasties incisions and the final shape of the breast?].

    Science.gov (United States)

    Moufarrège, R; Dionyssopoulos, A; Aymeric, A; Sauvageau, J

    2010-04-01

    The results of reduction mammoplasty and mastopexy demonstrate a great variety of shapes derived from the particularities inherent to each technique. More precisely, it has become apparent to us that the usage of an abnormally long vertical scar leads to a suboptimal final shape of the breast due to the excessive projection compared to its height. Although our clientele continually asks to minimize scars, we have noticed a resurgence in the literature of vertical incision mammoplasty techniques albeit with a scar of an excessive length. The multitude of publications leads to an evident and consistent conclusion: breasts reconstructed with an overly long vertical incision all suffer the same deformity characterized by a banana or squash-shaped breast. We studied the totality of publications on vertical incision technique mammoplasty from the last 15 years and realised they all presented the same problem: an abnormally low height/projection ratio. These numbers have been confronted by the golden ratio established by the first author (2005) [1]. The breast's golden ratio developed by Moufarrège is optimal at a number close to, or superior to 2. Results between 2 and 1.5 are acceptable. All height/projection ratios inferior to 1.5 correspond to suboptimal breast shapes. Furthermore, the totality of results in the vertical scar mammoplasty technique which displayed unsatisfying results had a height/projection ratio inferior to 1.5. Those who promote the vertical incision have the greatest drive to encourage other plastic surgeons to abandon the traditional mutilating boat anchor scar. Nevertheless, they should always remember the deforming effect caused by exaggerated vertical incisions which may be avoided by transforming it into an inverted T with short horizontal branches, a small price to pay to obtain a superior aesthetic result. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  18. High-power diode laser in the circumvestibular incision for Le Fort I osteotomy in orthognathic surgery: a prospective case series study.

    Science.gov (United States)

    Jaeger, Filipe; Chiavaioli, Gustavo Marques; de Toledo, Guilherme Lacerda; Freire-Maia, Belini; Amaral, Marcio Bruno Figueiredo; Mesquita, Ricardo Alves

    2018-01-01

    The incisions during orthognathic surgery are classically performed with conventional scalpel or electrocautery. Considering that the high-power diode laser surgery may provide advantages when compared to conventional incision techniques, the current study aimed to present a prospective case series of patients submitted to circumvestibular incision for Le Fort I osteotomy. Ten patients with dentofacial deformities who underwent to rapid assisted maxillary expansion or bimaxillary orthognathic surgery were enrolled in the study. All incisions were performed by a single surgeon using an 808-nm diode laser, with an optical fiber of 600 μm, at a power of 2.5 W, in a continuous-wave mode. The performance of the incision was evaluated by incision velocity, bleeding, edema, secondary infection, clinical healing, and pain. The velocity of the incision ranged from 0.10 to 0.20 mm/s (mean 0.13 ± 0.03 mm/s). Considering bleeding during the soft tissue incision, all surgeries were classified as absent bleeding. All patients presented a clinical healing of the surgical wound in a period that range from 3 to 5 weeks and experienced swelling during the follow-up period. On average, approximately 50% of the swelling had resolved after the third postoperative week, and 28.8% of swelling remained after 2 months after the surgery. The pain decreased after 2 and 3 days, and 90.0% of the patients reported no pain after 7 postoperative days. High-power diode laser is effective and safety during circumvestibular incisions for Le Fort I osteotomy in orthognathic surgery decreasing bleeding, surgery time, pain, and edema after orthognathic surgery.

  19. River longitudinal profiles and bedrock incision models: Stream power and the influence of sediment supply

    Science.gov (United States)

    Sklar, Leonard; Dietrich, William E.

    The simplicity and apparent mechanistic basis of the stream power river incision law have led to its wide use in empirical and theoretical studies. Here we identify constraints on its calibration and application, and present a mechanistic theory for the effects of sediment supply on incision rates which spotlights additional limitations on the applicability of the stream power law. On channels steeper than about 20%, incision is probably dominated by episodic debris flows, and on sufficiently gentle slopes, sediment may bury the bedrock and prevent erosion. These two limits bound the application of the stream power law and strongly constrain the possible combination of parameters in the law. In order to avoid infinite slopes at the drainage divide in numerical models of river profiles using the stream power law it is commonly assumed that the first grid cell is unchanneled. We show, however, that the size of the grid may strongly influence the calculated equilibrium relief. Analysis of slope-drainage area relationships for a river network in a Northern California watershed using digital elevation data and review of data previously reported by Hack reveal that non-equilibrium profiles may produce well defined slope-area relationships (as expected in equilibrium channels), but large differences between tributaries may point to disequilibrium conditions. To explore the role of variations in sediment supply and transport capacity in bedrock incision we introduce a mechanistic model for abrasion of bedrock by saltating bedload. The model predicts that incision rates reach a maximum at intermediate levels of sediment supply and transport capacity. Incision rates decline away from the maximum with either decreasing supply (due to a shortage of tools) or increasing supply (due to gradual bed alluviation), and with either decreasing transport capacity (due to less energetic particle movement) or increasing transport capacity (due less frequent particle impacts per unit bed

  20. CO2 temperature-controlled laser soldering of pig trachea incisions in vitro using flexible albumin bands

    Science.gov (United States)

    Sharvit, Dan; Vasilyev, Tamar; Vasserman, Irena; Simhon, David; Kariv, Naam; DeRowe, Ari; Katzir, Abraham

    2005-04-01

    Resection of a segment of the trachea is a procedure applied for the removal of cervical tumors invading the trachea, or for the treatment of severe tracheal stenosis. The current method of anastomosis is based on multiple sutures. The main drawbacks of this method are: 1) A long procedure time, 2) An air leakage, and 3) An inflammatory response to the sutures. In this study we evaluated the feasibility and effectiveness of the use of temperature controlled CO2 laser soldering of incisions in pig tracheas in vitro. A transverse incision was made in a separated pig trachea. A flexible albumin band was prepared and was laser soldered with albumin solder to the outer surface of the trachea, covering the incision. The soldered trachea ends were sealed and the burst pressure was measured. In a series of in vitro experiments, the mean burst pressure was found to be 230 mm Hg. These preliminary results demonstrated that laser soldering using a flexible albumin band may be a useful method for sealing an incision in the trachea.

  1. Single-incision laparoscopic distal gastrectomy for early gastric cancer through a homemade single port access device.

    Science.gov (United States)

    Jiang, Zhi-Wei; Zhang, Shu; Wang, Gang; Zhao, Kun; Liu, Jiang; Ning, Li; Li, Jieshou

    2015-01-01

    We presented a series of single-incision laparoscopic distal gastrectomies for early gastric cancer patients through a type of homemade single port access device and some other conventional laparoscopic instruments. A single-incision laparoscopic distal gastrectomy with D1 + α lymph node dissection was performed on a 46 years old male patient who had an early gastric cancer. This single port access device has facilitated the conventional laparoscopic instruments to accomplish the surgery and we made in only 6 minutes. Total operating time for this surgery was 240 minutes. During the operation, there were about 100 milliliters of blood loss, and 17 lymph-nodes were retrieved. This homemade single port access device shows its superiority in economy and convenience for complex single-incision surgeries. Single-incision laparoscopic distal gastrectomy for early gastric cancer can be conducted by experienced laparoscopic surgeons. Fully take advantage of both SILS and fast track surgery plan can bring to successful surgeries with minimal postoperative pain, quicker mobilization, early recovery of intestinal function, and better cosmesis effect for the patients.

  2. Characterization of surface topography and chemical composition of mini-implants

    OpenAIRE

    Knop, Luegya Amorim Henriques; Soares, Ana Prates; Shintcovsk, Ricardo Lima; Martins, Lidia Parsekian; Gandini Jr., Luiz Gonzaga

    2015-01-01

    Abstract Aim : To assess the surface topography and chemical composition of three brands of as-received mini-implants (SIN(r), Morelli(r), and Conexao(r)). Methods: Twelve mini-implants of each brand were analyzed by scanning electron microscopy and energy dispersive X-ray (EDX). Results: There was no significant differences among SIN(r), Morelli(r), and Conexao(r) mini-implants comparing their surface topography by visualization of SEM micrographs and analysis of scores. The EDX analysis ...

  3. Late time CMB anisotropies constrain mini-charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Burrage, C.; Redondo, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Jaeckel, J. [Univ. of Durham, Inst. for Particle Physics Phenomenology (United Kingdom)

    2009-09-15

    Observations of the temperature anisotropies induced as light from the CMB passes through large scale structures in the late universe are a sensitive probe of the interactions of photons in such environments. In extensions of the Standard Model which give rise to mini-charged particles, photons propagating through transverse magnetic fields can be lost to pair production of such particles. Such a decrement in the photon flux would occur as photons from the CMB traverse the magnetic fields of galaxy clusters. Therefore late time CMB anisotropies can be used to constrain the properties of mini- charged particles. We outline how this test is constructed, and present new constraints on mini-charged particles from observations of the Sunyaev-Zel'dovich effect in the Coma cluster. (orig.)

  4. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  5. Normalized Urinary Flow at Puberty after Tubularized Incised Plate Urethroplasty for Hypospadias in Childhood.

    Science.gov (United States)

    Andersson, Marie; Doroszkiewicz, Monika; Arfwidsson, Charlotte; Abrahamsson, Kate; Sillén, Ulla; Holmdahl, Gundela

    2015-11-01

    An obstructive urinary flow pattern is frequently seen after tubularized incised plate urethroplasty for hypospadias. However, the significance of this finding has not been determined and long-term results are few. We describe postoperative long-term uroflowmetry results after puberty in males who underwent tubularized incised plate urethroplasty in childhood. A total of 126 boys underwent tubularized incised plate urethroplasty for distal penile to mid shaft hypospadias at Queen Silvia Children's Hospital in Gothenburg between 1999 and 2003. Of the patients 48 were toilet trained at surgery. We report on 40 patients who had data available at 2 and 12 months postoperatively, 7 years postoperatively and at puberty (median age 15.0 years, range 13.7 to 17.1). Of the patients 31 had distal and 9 had mid penile hypospadias. Clinical examination, urinary medical history, uroflowmetry and ultrasound measuring residual urine were performed. Maximum urinary flow was correlated to age and voided volume, using Miskolc nomograms for comparison of percentiles. At 1 year postoperatively 15 boys (37.5%) had normal urinary flow (above 25th percentile), compared to 16 (40%) at 7 years and 38 (95%) at puberty (p puberty for boys with hypospadias treated with tubularized incised plate urethroplasty. Unless symptoms occur, a conservative approach seems preferable. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Mini-Grids for the Base of the Pyramid Market: A Critical Review

    Directory of Open Access Journals (Sweden)

    Subhes C. Bhattacharyya

    2018-04-01

    Full Text Available The lack of access to electricity of more than 1.1 billion people around the world remains a major developmental challenge and Goal 7 of the Sustainable Development Goals (SDG as well as Sustainable Energy for All (SE4ALL have set a target of universal electrification by 2030. Various studies have identified mini-grid-based electrification as a possible solution. There is a growing body of literature available now that has explored the feasibility, practical application and policy interventions required to support mini-grids. Through a review of available literature, this paper explores whether mini-grids can be a solution for the base of the pyramid (BoP market and the challenges faced in deploying mini-grids in such markets. Interventions to support the mini-grid deployment are also discussed. The paper finds that the mini-grids are targeting the BoP market but the business is not attractive in profitability terms and requires financial support. Lack of regulatory clarity and non-coordinated policies affect the financial viability of projects, which requires careful support. Mini-grid electrification has hardly been embedded in rural development agenda and hence they have not contributed significantly to livelihood generation. Careful realignment of policies, regulatory frameworks and support systems can better support mini-grid deployment in developing countries.

  7. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics.

    Science.gov (United States)

    El-Say, Khalid M; Ahmed, Tarek A; Abdelbary, Maged F; Ali, Bahaa E; Aljaeid, Bader M; Zidan, Ahmed S

    2015-12-01

    This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets) as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1), swelling pressure of the superdisintegrant (X2), and the surface area of Aerosil as a glidant (X3). Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for pre- and post-compression characteristics. The prepared OD-mini-tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2) and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  8. Utilização do tendão do músculo palmar longo em procedimentos cirúrgicos: estudo em cadáveres Use of the tendon of the palmaris longus muscle in surgical procedures: study on cadavers

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Angelini Júnior

    2012-01-01

    Full Text Available OBJETIVO: Demonstrar que o tendão do músculo palmar longo pode ser estimado em relação ao seu comprimento e largura antes de usá-lo como enxerto em procedimento cirúrgico. MÉTODOS: Foram examinados 60 antebraços de 30 cadáveres de etnia negra; mensurou-se o comprimento e a largura do tendão do músculo palmar longo e comparou-se com o comprimento do antebraço. RESULTADOS: Foi constatada a ausência unilateral direita em dois cadáveres do sexo feminino. As médias do comprimento e da largura foram respectivamente 11,9 mais ou menos 15,2mm e 4,1 + 1,5mm. A média total do comprimento do antebraço foi de 275.4mm mais ou menos 17,9mm. CONCLUSÃO: Há uma relação significativa entre o comprimento do tendão e o comprimento do antebraço; assim poder-se-á avaliar o tamanho do tendão do músculo palmar longo quando for necessário usá-lo para enxertos. Nível de Evidências IV, Série de casos.OBJECTIVE: Demonstrate that the tendon of palmar long can be estimated in relation to its length and width before using it as a graft in surgical procedure. METHODS: There were examined 60 forearms of 30 corpses of black ethnicity; measure the length and width of the tendon of the palmaris longus muscle and compared the length of the forearm. RESULTS: There are notes their absence unilateral right in two female corpses. The medium length and width were more or less respectively 11.9, 15.2 mm and 4.1 + 1.5 mm. The total average forearm length of 275.4 was more or less 17.9 mm. CONCLUSION: There is a significant relationship between the length of the tendon and the length of the forearm; so we can evaluate the size of the tendon of the palmaris longus muscle when it is necessary to use it for grafts. Levels of Evidence IV, Case series.

  9. Nd:YAG laser incision of the vesical neck in obstructive BPH

    Science.gov (United States)

    Gilbert, Peter T. O.

    2003-06-01

    From February, 1995 through June, 2002, 68 patients underwent laser incision of the prostate at our clinic. By means of a 23 F cytoscope and a 600 micrometer lateral firing quartz fiber the vesical neck was incised at the 5 and 7 o'clock position at 60 W power. Total energy averaged 13648 J. Operative time did not exceed 15 minutes. General anesthesia was employed in all but one patient. 38 patients remained catheter-free whereas 30 patients were catheterized for two hours. Except for three cases, all patients were discharged on the same day, usually after the first micturition. Anti-inflammatory treatment was administered for two weeks, Cotrimoxazole for 5 days. No serious complications were encountered. Minor side effects included urinary retention (1 pat.), urinary infection (3 pat.) and retrograde ejaculation (1 pat.). Considering a mean follow-up of 21 months, the average Qmax improved enormously (25.4 ml/s versus 10.9 ml/s), as did residual urine volume (35 ml versus 95 ml) and IPSS (7.1 versus 20.5). Three patients required TUR-P 2-3 years after laser surgery and one patient underwent radical retropubic prostatectomy for prostate cancer 2 years later. In conclusion, Nd:YAG laser incision of the prostate is a simple, safe, reliable and cost-effective outpatient procedure.

  10. Accelerated Tooth Movement with Orthodontic Mini-Screws

    Directory of Open Access Journals (Sweden)

    S. Aksakalli

    2017-01-01

    Full Text Available This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-year-old male patient presented Class II malocclusion with maxillary incisor protrusion. Upper first premolars were extracted, and after leveling, accelerated canine distalization started. For pre- and postdistalization times, amount of distalization, periodontal health, and root resorption were assessed. Within the limitations of this case report, micro-osteoperforations with mini-screw have a potential for shortening the treatment time.

  11. Infra Patellar Branch of Saphenous Nerve Injury during Hamstring Graft Harvest: Vertical versus Oblique Incisions.

    Science.gov (United States)

    Joshi, A; Kayasth, N; Shrestha, S; Kc, B R

    2016-09-01

    Autologous hamstring grafts are commonly used for anterior cruciate ligament reconstruction. The injury of infrapatellar branch of saphenous nerve is one of the concerns leading to various pattern of sensory loss in the operated leg. An oblique incision to harvest the graft has been reported to be better than the vertical one.The aim of this study was to compare the incidence, recovery of nerve injury and final outcome in patients with hamstring harvest of vertical or oblique incision. A total of 146 patients who underwent hamstring graft harvest for anterior cruciate ligament reconstruction, were included in the study. They were randomized into two (Vertical and Oblique) groups as per the incisions used. The sensory loss along the Infra Patellar Branch of Saphenous Nerve was documented on 3rd day. Recovery of the nerve injury was monitoredat three, six and 12 months follow-ups. At final follow up Tegner Lysholm score and scale was recorded to compare between two groups. The incidence of infrapatellar branch of saphenous nerve injury was 25% in vertical group and 16.36% in oblique group. Recovery of nerve injury started earlier in oblique group compared to vertical group. The mean TegnerLyshom score was not significantly different in both the groups. Oblique incision to harvest hamstring graft has lesser incidence of infrapatellar branch of saphenous nerve injury, recovers earlier and does not have any adverse effect on final outcome compared to the vertical incision.

  12. Predicting everyday functional abilities of dementia patients with the Mini-Mental State Examination.

    Science.gov (United States)

    Razani, Jill; Wong, Jennifer T; Dafaeeboini, Natalia; Edwards-Lee, Terri; Lu, Po; Alessi, Cathy; Josephson, Karen

    2009-03-01

    The Mini-Mental State Examination is a widely used cognitive screening measure. The purpose of the present study was to assess how 5 specific clusters of Mini-Mental State Examination items (ie, subscores) correlate with and predict specific areas of daily functioning in dementia patients, 61 patients with varied forms of dementia were administered the Mini-Mental State Examination and an observation-based daily functional test (the Direct Assessment of Functional Status). The results revealed that the orientation and attention subscores of the Mini-Mental State Examination correlated most significantly with most functional domains. The Mini-Mental State Examination language items correlated with all but the shopping and time orientation tasks, while the Mini-Mental State Examination recall items correlated with the Direct Assessment of Functional Status time orientation and shopping tasks. Stepwise regression analyses found that among the Mini-Mental State Examination subscores, orientation was the single, best independent predictor of daily functioning.

  13. Validity of a short clinical interview for psychiatric diagnosis: the mini-SCAN.

    Science.gov (United States)

    Nienhuis, F J; van de Willige, G; Rijnders, C A Th; de Jonge, P; Wiersma, D

    2010-01-01

    To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. To establish the validity and practical properties of the mini-SCAN. One hundred and six participants were interviewed twice, once with the SCAN and once with the mini-SCAN. The level of agreement was established for the categories: no disorder, affective disorders, anxiety disorders, non-affective psychotic disorders, affective psychotic disorders. The mini-SCAN is a valid instrument. Most kappa values were around 0.90. Only for the class of affective psychotic disorders was the agreement moderate. Mean duration of the mini-SCAN interviews was 25 min shorter than the SCAN interviews. Participants and interviewers were generally satisfied with the interview format and questions. The mini-SCAN can be used as a diagnostic instrument for clinical purposes and for clinical studies when the present episode is the focus of attention.

  14. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  15. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  16. Virtual Incision Pattern Planning using Three-Dimensional Images for Optimization of Syndactyly Surgery

    Directory of Open Access Journals (Sweden)

    Inge A. Hoevenaren, MD

    2018-03-01

    Full Text Available Summary:. Syndactyly is a congenital condition characterized by fusion of the fingers. If not treated correctly during infancy, syndactyly may hinder the normal development of hand function. Many surgical techniques have been developed, with the main goal to create a functional hand with the smallest number of operative corrections. Therefore, exact preoperative planning of the reconstructive procedure is essential. An imaging method commonly used for preoperative planning is 3-dimensional (3D surface imaging. The goal of this study was to implement the use of this technique in hand surgery, by designing a virtual planning tool for a desyndactylization procedure based on 3D hand images. A 3D image of a silicon syndactyly model was made on which the incision pattern was virtually designed. A surgical template of this pattern was printed, placed onto the silicon model and delineated. The accuracy of the transfer from the virtual delineation toward the real delineation was calculated, resulting in a mean difference of 0.82 mm. This first step indicates that by using 3D images, a virtual incision pattern can be created and transferred back onto the patient successfully in an easy and accurate way by using a template. Thereafter, 3D hand images of 3 syndactyly patients were made, and individual virtual incision patterns were created. Each pattern was transferred onto the patient by using a 3D printed template. The resulting incision pattern needed minor modifications by the surgeon before the surgery was performed. Further research and validation are necessary to develop the virtual planning of desyndactylization procedures.

  17. Quantifying incision rates since the early Miocene: novelties, potentialities and limitations

    Science.gov (United States)

    Sartégou, A.; Braucher, R.; Blard, P. H.; Bourlès, D. L.; Zimmermann, L.; Tibari, B.; Voinchet, P.; Bahain, J. J.; Sorriaux, P.; Leanni, L.; Team, A.

    2017-12-01

    The rates and chronologies of valley incision are closely modulated by the tectonic uplift of active mountain ranges and were controlled by repeated climate changes during the Quaternary. The Pyrenees are a continental collision between the Iberian and Eurasian plates induced a double vergence orogen, which has been considered as a mature mountain range in spite of significant seismicity and evidence of neotectonics. Nevertheless, recent studies indicate that the range may have never reached a steady state. One option for resolving this controversy is to quantify the incision rates since the Miocene by reconstructing the vertical movement of geometric markers. However, the few available ages from the Pyrenean terrace systems do not exceed the middle Pleistocene. To enlarge the time span of this dataset, we studied alluvium-filled horizontal epiphreatic passages in limestone karstic networks, which represent former valley floors. They record the transient position of former local base levels during the process of valley deepening. We used various suitable geochronological methods (26Al/10Be, 10Be/21Ne, ESR and OSL burial durations on quartz) on intrakarstic alluvial deposits from three valleys of the central and eastern Pyrenees, as well as on a recent analogue. In the Pyrenean context, under particular conditions, these geochronometers allow us to document incision processes since 16-13 Ma, and to study influences of external forcing and eustatism. In comparison with other studies, it appears that incision rates are higher in the central Pyrenees and for the Spanish slope. However, the density of horizontal levels on an altimetric range, the geodynamical and paleoclimatic contexts, the reorganization of the drainage networks can make the filling stories of the networks more complex than expected. Indeed, these radiometric approaches may be limited when some formations are reworked inside and/or outside the karst. The validity of dosimetric methods in a mountainous

  18. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  19. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  20. Delphi report 1995 on developments in science and technology. Mini Delphi; Delphi-Bericht 1995 zur Entwicklung von Wissenschaft und Technik. Mini-Delphi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    In August 1993 the first German `Delphi Report on Developments in Science and Technology` was published. It was elaborated by the Fraunhofer Institute for System Engineering and Innovation Research (FhG-ISI) in cooperation with the Japanese National Institute of Science and Technology Policy (NISTEP). The `MINI-DELPHI` now completed by FhG-ISI, again in cooperation with NISTEP, is a further development of the Delphi approach in that it is more differentiated in its questions and assessment criteria than its predecessors. `MINI-DELPHI` is not intended as a comprehensive forecast on technology in general but rather focusses on key topics. Its emphasis is on technology demand and the relevance of technologies to social issues. Although the Mini-Delphi study was primarily aimed at further refining the methodology employed, it nevertheless contains a wealth of information and details on circumscript questions. The requisite database is provided by tables on the results of two inquiry rounds among Japanese and German experts. (orig./RHM) [Deutsch] Im August 1993 wurde der erste deutsche `Delphi-Bericht zur Entwicklung von Wissenschaft und Technik` veroeffentlicht. Er war vom Fraunhofer-Institut fuer Systemtechnik und Innovationsforschung (FhG-ISI) in Zusammenarbeit mit dem japanischen National Institute of Science and Technology Policy (NISTEP) erarbeitet worden. Mit dem jetzt vorliegenden `MINI-DELPHI` hat das FhG-ISI - wieder in Zusammenarbeit mit dem NISTEP - den Delphi-Ansatz fortentwickelt und sowohl hinsichtlich der Fragen als auch der Beurteilungskriterien weiter ausdifferenziert. `MINI-DELPHI` bezweckt keine umfassende Technologievorausschau, sondern konzentriert sich auf Schluesselthemen. Im Vordergrund steht der Gedanke des Technikbedarfs und die Relevanz fuer gesellschaftliche Fragestellungen. Obwohl die Mini-Delphi-Studie vorrangig der Weiterentwicklung der Methodik dient, enthaelt sich eine Fuelle von Informationen und Details zu Einzelfragen. Die im Bericht

  1. Designing a mini subcritical nuclear reactor

    International Nuclear Information System (INIS)

    Escobedo G, C. R.; Vega C, H. R.; Davila H, V. M.

    2015-10-01

    In this work the design of a mini subcritical nuclear reactor formed by means of light water moderator, uranium as fuel, and isotopic neutron source of 239 PuBe was carried out. The design was done by Monte Carlo methods with the code MCNP5 in which uranium was modeled in an array of concentric holes cylinders of 8.5, 14.5, 20.5, 26.5, 32.5 cm of internal radius and 3 cm of thickness, 36 cm of height. Different models were made from a single fuel cylinder (natural uranium) to five. The neutron source of 239 PuBe was situated in the center of the mini reactor; in each arrangement was used water as moderator. Cross sections libraries Endf/Vi were used and the number of stories was large enough to ensure less uncertainty than 3%. For each case the effective multiplication factor k e -f f , the amplification factor and the power was calculated. Outside the mini reactor the ambient dose equivalent H (10) was calculated for different cases. The value of k eff , the amplification factor and power are directly related to the number of cylinders of uranium as fuel. Although the average energy of the neutrons 239 PuBe is between 4.5 and 5 MeV in the case of the mini reactor for a cylinder, in the neutron spectrum the presence of thermal neutrons does not exist, so that produced fissions are generated with fast neutrons, and in designs of two and three rings the neutron spectra shows the presence of thermal neutrons, however the fissions are being generated with fast neutrons. Finally in the four and five cases the amount of moderator is enough to thermalized the neutrons and thereby produce the fission. The maximum value for k eff was 0.82; this value is very close to the assembly of Universidad Autonoma de Zacatecas generating a k eff of 0.86. According to the safety and radiation protection standards for the design of mini reactor of one, two and three cylinders they comply with the established safety, while designs of four and five cylinders not met. (Author)

  2. Internal Structure of Mini-CEX Scores for Internal Medicine Residents: Factor Analysis and Generalizability

    Science.gov (United States)

    Cook, David A.; Beckman, Thomas J.; Mandrekar, Jayawant N.; Pankratz, V. Shane

    2010-01-01

    The mini-CEX is widely used to rate directly observed resident-patient encounters. Although several studies have explored the reliability of mini-CEX scores, the dimensionality of mini-CEX scores is incompletely understood. Objective: Explore the dimensionality of mini-CEX scores through factor analysis and generalizability analysis. Design:…

  3. Mini-Digest of Education Statistics, 2008. NCES 2009-021

    Science.gov (United States)

    Snyder, Thomas D.

    2009-01-01

    This publication is the 14th edition of the "Mini-Digest of Education Statistics," a pocket-sized compilation of statistical information covering the broad field of American education from kindergarten through graduate school. The "Mini-Digest" is designed as an easy reference for materials found in much greater detail in the…

  4. Fibrous mini-collagens in hydra nematocysts.

    Science.gov (United States)

    Holstein, T W; Benoit, M; Herder, G V; David, C N; Wanner, G; Gaub, H E

    1994-07-15

    Nematocysts (cnidocysts) are exocytotic organelles found in all cnidarians. Here, atomic force microscopy and field emission scanning electron microscopy reveal the structure of the nematocyst capsule wall. The outer wall consists of globular proteins of unknown function. The inner wall consists of bundles of collagen-like fibrils having a spacing of 50 to 100 nanometers and cross-striations at intervals of 32 nanometers. The fibrils consist of polymers of "mini-collagens," which are abundant in the nematocysts of Hydra. The distinct pattern of mini-collagen fibers in the inner wall can provide the tensile strength necessary to withstand the high osmotic pressure (15 megapascals) in the capsules.

  5. Concerning production and decay of mini black holes

    CERN Document Server

    Hajdukovic, D

    2007-01-01

    In the next few years, theories predicting possibility to create mini black holes will be tested at CERN. Either experimental verification or rejection of these theories is of great scientific importance. There is a large consensus that, if successfully created, these short living mini black holes will decay through thermal (Hawking's) radiation. In the present comment we point out, that under assumption of the gravitational repulsion between matter and antimatter (in short we call it antigravity), thermal radiation may be dominated by a non-thermal radiation (being the consequence of pair creation from the vacuum, by gravitational field, which in the case of antigravity, pushes particles and antiparticles in opposite directions). Thus, the eventual creation of mini black holes may turn to be an unexpected opportunity to test the existence of antigravity.

  6. Type of incision does not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Oma, Erling; Harling, Henrik

    2017-01-01

    for anastomotic leakage were included with a median follow-up of 5.4 years. Incisional hernia occurred in 41 of 227 (15.3%) patients undergoing midline incision compared with 14 of 81 (14.7%) following transverse incision, P = 1.00. After adjusting for confounders, there was no association between the type...... not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage....

  7. Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment.

    Science.gov (United States)

    Lee, Jin-Hwa; Choo, Hyeran; Kim, Seong-Hun; Chung, Kyu-Rhim; Giannuzzi, Lucille A; Ngan, Peter

    2011-06-01

    When mini-implants fail during orthodontic treatment, there is a need to have a backup plan to either replace the failed implant in the adjacent interradicular area or wait for the bone to heal before replacing the mini-implant. We propose a novel way to overcome this problem by replacement with a miniplate so as not to interrupt treatment or prolong treatment time. The indications, advantages, efficacy, and procedures for switching from a mini-implant to a miniplate are discussed. Two patients who required replacement of failed mini-implants are presented. In the first patient, because of the proximity of the buccal vestibule to the mini-implant, it was decided to replace the failed mini-implant by an I-shaped C-tube miniplate. In the second patient, radiolucencies were found around the failed mini-implants, making the adjacent alveolar bone unavailable for immediate placement of another mini-implant. In addition, the maxillary sinus pneumatization was expanded deeply into the interradicular spaces; this further mandated an alternative placement site. One failed mini-implant was examined under a scanning electron microscope for bone attachment. Treatment was completed in both patients after replacement with miniplates without interrupting the treatment mechanics or prolonging the treatments. Examination under the scanning electron microscope showed partial bone growth into the coating pores and titanium substrate interface even after thorough cleaning and sterilization. Replacement with a miniplate is a viable solution for failed mini-implants during orthodontic treatment. The results from microscopic evaluation of the failed mini-implant suggest that stringent guidelines are needed for recycling used mini-implants. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. Can post-sternotomy mediastinitis be prevented by a closed incision management system?

    Directory of Open Access Journals (Sweden)

    Dohmen, Pascal M.

    2014-09-01

    Full Text Available [english] Post-sternotomy mediastinitis is a serious complication after cardiothoracic surgery and contribute significantly to post-operative morbidity, mortality, and healthcare costs. Negative pressure wound therapy is today’s golden standard for post-sternotomy mediastinitis treatment. A systematic literature search was conducted at PubMed until October 2012 to analyse whether vacuum-assisted closure technique prevents mediastinitis after clean surgical incisions closure. Today’s studies showed reduction of post-sternotomy mediastinitis including a beneficial socio-economic impact. Current studies, however included only high-risk patients, hence furthermore, larger randomised controlled trials are warranted to clarify the benefit for using surgical incision vacuum management systems in the general patient population undergoing sternotomy and clarify risk factor interaction.

  9. Solo Single-Incision Laparoscopic Resectional Roux-en-Y Gastric Bypass for Morbid Obesity with Metabolic Syndrome.

    Science.gov (United States)

    Kang, So Hyun; Lee, Yoontaek; Park, Young Suk; Ahn, Sang-Hoon; Park, Do Joong; Kim, Hyung-Ho

    2017-12-01

    With the advancement of laparoscopic devices and surgical technology, the era of minimal invasive surgery has progressed to reduced-port surgery, and finally to single-incision laparoscopic surgery (SILS). Several reports show successful application of SILS to various types of bariatric surgery. Oftentimes, this requires a skilled and experienced scopist to perform the procedure. To overcome the technical difficulties of single-incision Roux-en-Y gastric bypass, a manual scope holder was used instead of an assistant scopist, greatly stabilizing the field of view. This allows the surgery to be performed at any time without being influenced by the need of a highly experienced scopist. In this report, we describe in detail the world's first solo single-incision laparoscopic resectional Roux-en-Y gastric bypass.

  10. Evaluation of mini super computers for nuclear design applications

    International Nuclear Information System (INIS)

    Altomare, S.; Baradari, F.

    1987-01-01

    The evolution of the mini super computers will force changes from the current environment of performing nuclear design calculations on mainframe computers (such as a CRAY) to mini super computers. This change will come about for a number of reasons. First, the mini super computers currently available in the marketplace offer the power and speed comparable to mainframes and can provide the capability to support highly computer intensive calculations. Second, the equipment is physically smaller and can easily be installed and operated without extensive investments in facilities and operations support. Third, the computer capacity can be acquired with as much needed memory, disk, and tape capacity as may be needed. Another reasons is that the performance/cost ratio has increased drastically as hardware costs have decreased. A study was conducted at the Westinghouse Commercial Nuclear Fuel Division (CNFD) to evaluate the mini super computers for use in nuclear core design. As a result of this evaluation, Westinghouse CNFD is offering a combined hardware/software technology transfer package for core design. This package provides the utility designer with a totally dedicated mini super computer comparable in speed to the CRAY 1S with sufficient capacity for a sizable design group to perform the engineering activities related to nuclear core design and operations support. This also assures the utility of being totally compatible with the CNFD design codes, thus assuring total update compatibility

  11. Mini-clinical evaluation exercise til evaluering af kommunikation og samarbejde i ambulatoriet

    DEFF Research Database (Denmark)

    Eriksen, Jesper Grau; Simonsen, Dorit; Bastholt, Lars

    2009-01-01

    INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation of communi......INTRODUCTION: In the revised Danish medical specialist training increased focus has been placed on competences which are hard to evaluate such as communication skills. Mini-CEX seems promising as an evaluation tool. Our aim was to test: 1) whether mini-CEX was useable in the evaluation...

  12. Injuries in Japanese Mini-Basketball Players During Practices and Games

    Science.gov (United States)

    Kuzuhara, Kenji; Shibata, Masashi; Uchida, Ryo

    2016-01-01

    Context: Mini-basketball is one of the most popular junior sports in Japan. Mini-basketball–related injuries may increase because of early specialization. However, no reports have been published to date concerning basketball injuries in children younger than 12 years of age. Objective: To prospectively study the incidence, sites, types, and mechanisms of injuries in mini-basketball teams. Design: Descriptive epidemiology study. Setting: Mini-basketball teams in Kobe, Japan. Patients or Other Participants: A total of 95 players in 7 community-based mini-basketball club teams (age range, 9 through 12 years). Main Outcome Measure(s): Data on all practice and game injuries for the 2013–2014 season were collected using an injury report form. Injury rates were calculated according to site, type, and mechanism. Results: The overall injury rate was 3.83 per 1000 athlete-hours (AHs). The game injury rate (12.92/1000 AHs) was higher than the practice injury rate (3.13/1000 AHs; P basketball players. The high practice injury rate in this study may be due to specific factors related to growth, such as individual differences in height, or to skills, such as inexperience in ball handling. PMID:27922287

  13. Gender and Self-Employment: The Role of Mini-Companies

    Science.gov (United States)

    Johansen, Vegard

    2016-01-01

    Purpose: The purpose of this paper is to evaluate to what degree participation in mini-companies impact young women and men with regard to the perceived desirability and perceived feasibility of self-employment. The Company Programme (CP) is the largest mini-company scheme in European secondary school. Design/methodology/approach: The data derived…

  14. Afrique : ressources minières, environnement et gouvernance ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    25 janv. 2011 ... ils regorgent de richesses inouïes », assure Bonnie Campbell, directrice du Groupe de recherche sur les activités minières en Afrique (GRAMA) et titulaire de la Chaire C.-A. Poissant de recherche sur la gouvernance et l'aide au développement, faisant référence aux ressources minières et pétrolières dont ...

  15. MiniDLNA_tweaker : Aplicació per configurar i previsualitzar el servidor MiniDLNA per a GNU/Linux

    OpenAIRE

    Martínez Lloveras, Jordi

    2013-01-01

    L'aplicació MiniDLNA per a GNU/Linux és un servidor lleuger que compleix els estàndards DLNA/UPnP configurable a través d'un simple arxiu de text, això la fa ideal per al propòsit d'implantació d'un servidor que ofereixi els continguts a tots els dispositius que compleixin els estàndards esmentats. La aplicación MiniDLNA para GNU/Linux es un servidor ligero que cumple los estándares DLNA/UPnP configurable a través de un simple archivo de texto, esto la hace ideal para el propósito de impla...

  16. Maternal infection rates after cesarean delivery by Pfannenstiel or Joel-Cohen incision: a multicenter surveillance study.

    Science.gov (United States)

    Dumas, Anne Marie; Girard, Raphaële; Ayzac, Louis; Caillat-Vallet, Emmanuelle; Tissot-Guerraz, Françoise; Vincent-Bouletreau, Agnès; Berland, Michel

    2009-12-01

    Our purpose was to evaluate maternal nosocomial infection rates according to the incision technique used for caesarean delivery, in a routine surveillance study. This was a prospective study of 5123 cesarean deliveries (43.2% Joel-Cohen, 56.8% Pfannenstiel incisions) in 35 maternity units (Mater Sud Est network). Data on routine surveillance variables, operative duration, and three additional variables (manual removal of the placenta, uterine exteriorization, and/or cleaning of the parieto-colic gutter) were collected. Multiple logistic regression analysis was used to identify independent risk factors for infection. The overall nosocomial infection and endometritis rates were higher for the Joel-Cohen than Pfannenstiel incision (4.5% vs. 3.3%, 0.8% vs. 0.3%, respectively). The higher rate of nosocomial infections with the Joel-Cohen incision was due to a greater proportion of patients presenting risk factors (i.e., emergency delivery, primary cesarean, blood loss > or =800 mL, no manual removal of the placenta and no uterine exteriorization). However, the Joel-Cohen technique was an independent risk factor for endometritis. The Joel-Cohen technique is faster than the Pfannenstiel technique but is associated with a higher incidence of endometritis.

  17. Addition of rectus sheath relaxation incisions to emergency midline laparotomy for peritonitis to prevent fascial dehiscence.

    Science.gov (United States)

    Marwah, Sanjay; Marwah, Nisha; Singh, Mandeep; Kapoor, Ajay; Karwasra, Rajender Kumar

    2005-02-01

    The incidence of fascial dehiscence and incisional hernia after two methods for abdominal wound closure (rectus sheath relaxation incisions and conventional mass closure) was studied in a randomized prospective clinical trial in a consecutive series of 100 patients undergoing midline laparotomy for peritonitis. The two groups were well matched for etiologies of peritonitis, the surgical procedures performed, and the presence of known risk factors for fascial dehiscence. Fifty patients each were randomized either to the conventional continuous mass closure procedure or the rectus sheath relaxation incision technique (designed to increase wound elasticity and decrease tension in the suture line) using identical polypropylene sutures. The incidence of postoperative complications such as duration of ileus, chest infection, and wound infection were not statistically different between the two groups. The intensity of postoperative pain in the rectus sheath relaxation incision group was significantly less. The incidence of wound hematoma was significantly increased in the rectus sheath relaxation incision group. The incidences of fascial dehiscence (16% vs,28%; p cases of peritonitis using the rectus sheath relaxation technique is safe and less painful, provides increased wound elasticity and decreased tension on the suture line, and significantly decreases the incidence of wound dehiscence.

  18. Agreement between clinical and MINI diagnoses in outpatients with mood and anxiety disorders

    NARCIS (Netherlands)

    Verhoeven, F. E. A.; Swaab, L. S. M. A.; Carlier, I. V. E.; van Hemert, A. M.; Zitman, F. G.; Ruhé, H. G.; Schoevers, R. A.; Giltay, E. J.

    2017-01-01

    Background: Standardized Diagnostic Interviews (SDIs) such as the Mini International Neuropsychiatric Interview (MINI) are widely used to systematically screen for psychiatric disorders in research. To support generalizability of results to clinical practice, we assessed agreement between the MINI

  19. Feasibility of single-incision laparoscopic surgery for appendicitis in abnormal anatomical locations: A single surgeon′s initial experience

    Directory of Open Access Journals (Sweden)

    Sanoop K Zachariah

    2013-01-01

    Full Text Available Background: Single-incision laparoscopic surgery is considered as a more technically demanding procedure than the standard laparoscopic surgery. Based on an initial and early experience, single-incision laparoscopic appendectomy (LA was found to be technically advantageous for dealing with appendicitis in unusual anatomical locations. This study aims to highlight the technical advantages of single-incision laparoscopic surgery in dealing with the abnormally located appendixes and furthermore report a case of acute appendicitis occurring in a sub-gastric position, which is probably the first such case to be reported in English literature. Materials and Methods: A retrospective analysis of the first 10 cases of single-incision LA which were performed by a single surgeon is presented here. Results: There were seven females and three males. The mean age of the patients was 30.6 (range 18-52 years, mean BMI was 22.7 (range 17-28 kg/m 2 and the mean operative time was 85.5 (range 45-150 min. The mean postoperative stay was 3.6 (range 1-7 days. The commonest position of the appendix was retro-caecal (50% followed by pelvic (30%. In three cases the appendix was found to be in abnormal locations namely sub-hepatic, sub-gastric and deep pelvic or para-vesical or para-rectal. All these cases could be managed with this technique without any conversions Conclusion: Single-incision laparoscopic surgery appears to be a feasible and safe technique for dealing with appendicitis in rare anatomical locations. Appendectomy may be a suitable procedure for the initial training in single-incision laparoscopic surgery.

  20. Do dual-thread orthodontic mini-implants improve bone/tissue mechanical retention?

    Science.gov (United States)

    Lin, Yang-Sung; Chang, Yau-Zen; Yu, Jian-Hong; Lin, Chun-Li

    2014-12-01

    The aim of this study was to understand whether the pitch relationship between micro and macro thread designs with a parametrical relationship in a dual-thread mini-implant can improve primary stability. Three types of mini-implants consisting of single-thread (ST) (0.75 mm pitch in whole length), dual-thread A (DTA) with double-start 0.375 mm pitch, and dual-thread B (DTB) with single-start 0.2 mm pitch in upper 2-mm micro thread region for performing insertion and pull-out testing. Histomorphometric analysis was performed in these specimens in evaluating peri-implant bone defects using a non-contact vision measuring system. The maximum inserted torque (Tmax) in type DTA was found to be the smallest significantly, but corresponding values found no significant difference between ST and DTB. The largest pull-out strength (Fmax) in the DTA mini-implant was found significantly greater than that for the ST mini-implant regardless of implant insertion orientation. Mini-implant engaged the cortical bone well as observed in ST and DTA types. Dual-thread mini-implant with correct micro thread pitch (parametrical relationship with macro thread pitch) in the cortical bone region can improve primary stability and enhanced mechanical retention.

  1. The Galactic Centre Mini-Spiral with CARMA

    Science.gov (United States)

    Kunneriath, D.; Eckart, A.; Vogel, S. N.; Teuben, P.; Muzic, K.; Schodel. R.; Garcia-Marin, M.; Moultaka, J.; Staguhn, J.; Straubmeier, C.; hide

    2012-01-01

    The Galactic centre mini-spiral region is a mixture of gas and dust with temperatures ranging from a few hundred K to 10(exp 4) K. We report results from 1.3 and 3mm radio interferometric observations of this region with CARMA, and present a spectral index map of this region. We find a range of emission mechanisms in the region, including the inverted synchrotron spectrum of Sgr A*, free-free emission from the mini-spiral arms, and a possible dust emission contribution indicated by a positive spectral index.

  2. Photovoltaic energy mini-generation: Future perspectives for Portugal

    International Nuclear Information System (INIS)

    Carvalho, Duarte; Wemans, Joao; Lima, Joao; Malico, Isabel

    2011-01-01

    This paper evaluates the benefits of developing the mini-generation PV market in Portugal. It presents the legal framework and current status of the Portuguese PV electricity sector, and compares the country to other European nations: France, Germany, Greece, Italy, Spain and the United Kingdom. A model that combines PVGIS with a self-developed financial tool is used to assess the feasibility of a 150 kW mini-generation system using five different technologies: fixed mount, single-axis tracking, double-axis tracking, low concentration and medium concentration (MCPV). The profitability of the mini-generation systems in the seven countries studied is calculated and compared. According to this analysis, MCPV and, of the conventional technologies, the single-axis tracking systems are the most profitable technologies. Despite the attractiveness of the current Portuguese feed-in tariffs and of the abundant solar resource, investors are discouraged and the country's PV market is far from mature. Specific mini-generation regulations should focus on a fast and transparent licensing procedure and should promote the access to financing. This would attract new investments, which would result in the growth of the PV electricity produced, and would help Portugal to meet its European Union Renewable Energy targets. - Highlights: → This work promotes the development of a mini-generation PV market in Portugal. → The Portuguese current status and legal framework is compared to other EU countries. → The profitability of 5 different PV technologies is compared for 7 European countries. → The Portuguese growth potential for PV energy is still big. → Portugal, due to its radiation levels, presents excellent investment opportunities.

  3. [Surgical treatment for incisions fat colliquation or infections at early stage after operation of lumbar disc herniation].

    Science.gov (United States)

    Guan, Ting-Jin; Zheng, Liang-Guo; Sun, Peng; Li, Xing-Xue

    2014-05-01

    To explore the reason, key diagnosic point and therapeutic method of the incisions fat colliquation or infections at early stage after operation of lumbar disc herniation. From July 2007 to May 2012, clinical data of 11 patients with incision fat liquefaction or early infection after lumbar discectomy were retrospectively analyzed. There were 5 males and 6 females with an average age of 43.1 years, and the mean time of incisions fat colliquation or infection was 5 days and a half after operation. The main clinical features included local wound pain aggravating, fervescence, fresh seepage in the wound, and blood inflammatory index increased, etc. The wound could heal at the first treatment stage or not was an evaluation standard of curative effect. All patients were followed up with an average period of 21 months. The wounds of 10 cases healed at the first stage without recurrence and complications. In 1 case infected by staphylococcus aureus, distal part of the wound present local red, swelling and with wave motion at 2 months after operation, staphylococcus aureus infection was confirmed after puncture and bacterial culture, and 1 thrum was found after local incision. The wound healed after change dressings for 1 week, without recurrence after followed up for 13 months. Preventing the risk factors before operation, minimizing invasive technique during operation reasonable antibiotics application for the lumbar operation reguiring placement objects, and correctly handling with wound after operation could prevent and reduce the incidence of incisions fat liquefaction or infection after operation of lumbar disc herniation. For incision fat liquefaction or infection, early diagnosis, debridement, VSD negative pressure irrigation and drainage, to choosing sensitive antibiotics according to the results of drug sensitivity, may contribute to wound early healing and decrease complication.

  4. Feasibility of Performing Total Skin-Sparing Mastectomy in Patients With Prior Circumareolar Mastopexy or Reduction Mammoplasty Incisions.

    Science.gov (United States)

    Vaughn, Carolyn J; Peled, Anne Warren; Esserman, Laura J; Foster, Robert D

    2013-06-19

    Total skin-sparing mastectomy (TSSM) techniques with preservation of the nipple-areolar complex (NAC) skin are becoming increasingly popular due to improved cosmesis without compromise in oncologic safety. However, these techniques are not routinely offered to patients who have undergone previous breast surgery involving circumareolar incisions due to concern for NAC viability. We reviewed the outcomes of TSSM in 11 patients who underwent 21 TSSM procedures at our institution between 2008 and 2011. All patients had undergone previous breast surgery including reduction mammaplasty (7 breasts), mastopexy (4 breasts), augmentation (3 breasts), and combined mastopexy-augmentation (7 breasts). Incisions from previous breast surgery included circumareolar (11 cases) and Wise pattern (10 cases) incisions. All patients underwent TSSM through an inframammary incision followed by immediate tissue expander reconstruction and subsequent implant exchange. Patient demographics, previous breast surgery details, tumor and treatment characteristics, and postoperative complications were reviewed. Mean patient age was 43 years (range, 35-53 years) and mean body mass index was 24 kg/m (range, 19-32 kg/m). Mean follow-up was 10.2 months (range, 3-20 months).Indications for TSSM included prophylactic risk reduction in 10 cases, in situ cancer in 2 cases, and invasive cancer in 9 cases. Mean time from previous breast surgery to mastectomy was 6.9 years (range, 6 months-26 years). Major complications requiring operative reintervention included 1 (4.8%) case of cellulitis requiring expander removal and 2 (9.5%) cases of wound breakdown requiring operative closure. There were no complications involving the NAC. Total skin-sparing mastectomy with immediate reconstruction can safely be performed in patients who have undergone previous breast surgery involving circumareolar incisions. Our preferred technique in this group of patients is to perform TSSM through an inframammary incision with 2

  5. Cannabidiol Is a Potential Therapeutic for the Affective-Motivational Dimension of Incision Pain in Rats

    Directory of Open Access Journals (Sweden)

    Karina Genaro

    2017-06-01

    Full Text Available Background: Pain involves different brain regions and is critically determined by emotional processing. Among other areas, the rostral anterior cingulate cortex (rACC is implicated in the processing of affective pain. Drugs that interfere with the endocannabinoid system are alternatives for the management of clinical pain. Cannabidiol (CBD, a phytocannabinoid found in Cannabis sativa, has been utilized in preclinical and clinical studies for the treatment of pain. Herein, we evaluate the effects of CBD, injected either systemically or locally into the rACC, on mechanical allodynia in a postoperative pain model and on the negative reinforcement produced by relief of spontaneous incision pain. Additionally, we explored whether CBD underlies the reward of pain relief after systemic or rACC injection.Methods and Results: Male Wistar rats were submitted to a model of incision pain. All rats had mechanical allodynia, which was less intense after intraperitoneal CBD (3 and 10 mg/kg. Conditioned place preference (CPP paradigm was used to assess negative reinforcement. Intraperitoneal CBD (1 and 3 mg/kg inverted the CPP produced by peripheral nerve block even at doses that do not change mechanical allodynia. CBD (10 to 40 nmol/0.25 μL injected into the rACC reduced mechanical allodynia in a dose-dependent manner. CBD (5 nmol/0.25 μL did not change mechanical allodynia, but reduced peripheral nerve block-induced CPP, and the higher doses inverted the CPP. Additionally, CBD injected systemically or into the rACC at doses that did not change the incision pain evoked by mechanical stimulation significantly produced CPP by itself. Therefore, a non-rewarding dose of CBD in sham-incised rats becomes rewarding in incised rats, presumably because of pain relief or reduction of pain aversiveness.Conclusion: The study provides evidence that CBD influences different dimensions of the response of rats to a surgical incision, and the results establish the rACC as a

  6. Disposable skin staplers for closure of linear gastrointestinal incisions in dogs.

    Science.gov (United States)

    Schwartz, Zeev; Coolman, Bradley R

    2018-02-01

    To report the clinical features and outcomes of linear gastrointestinal incisions closed with skin staples in dogs. Historical cohort study. 333 client-owned dogs. Medical records from 1 private referral hospital were searched for dogs that underwent gastrointestinal surgery between November 1999 and October 2015. Cases were included if skin staplers were used to close linear gastrointestinal incisions. Information regarding preoperative, surgical, and postoperative factors was collected. Complications were diagnosed in 8 of 245 (3.27%) dogs, including 3 of 245 (1.22%) dogs that died or were euthanized, 3 of 245 (1.22%) dogs with incisional dehiscence, and 2 of 245 (0.81%) dogs with attachment of a linear foreign body to the staples at the intestinal lumen. Dehiscence was noted at the enterotomy sites in 3 dogs at a mean time of 44 hours after surgery (SD ± 6.93). Two dogs presented with another linear foreign body that was attached to the staples in the intestinal lumen at postoperative days 24 and 42. The risk factors associated with incisional dehiscence included multiple gastrointestinal incisions performed in 1 surgery (χ 2 , P indication for surgical intervention, surgery location in the gastrointestinal tract, or surgeon experience and incisional dehiscence. Skin staplers provide safe and effective closure of gastrotomies, enterotomies, and colonotomies in dogs. This method is reliable, efficient, and affordable in the hands of veterinary surgeons with varying skill levels. © 2017 The American College of Veterinary Surgeons.

  7. Modeling Long-Term Fluvial Incision : Shall we Care for the Details of Short-Term Fluvial Dynamics?

    Science.gov (United States)

    Lague, D.; Davy, P.

    2008-12-01

    Fluvial incision laws used in numerical models of coupled climate, erosion and tectonics systems are mainly based on the family of stream power laws for which the rate of local erosion E is a power function of the topographic slope S and the local mean discharge Q : E = K Qm Sn. The exponents m and n are generally taken as (0.35, 0.7) or (0.5, 1), and K is chosen such that the predicted topographic elevation given the prevailing rates of precipitation and tectonics stay within realistic values. The resulting topographies are reasonably realistic, and the coupled system dynamics behaves somehow as expected : more precipitation induces increased erosion and localization of the deformation. Yet, if we now focus on smaller scale fluvial dynamics (the reach scale), recent advances have suggested that discharge variability, channel width dynamics or sediment flux effects may play a significant role in controlling incision rates. These are not factored in the simple stream power law model. In this work, we study how these short- term details propagate into long-term incision dynamics within the framework of surface/tectonics coupled numerical models. To upscale the short term dynamics to geological timescales, we use a numerical model of a trapezoidal river in which vertical and lateral incision processes are computed from fluid shear stress at a daily timescale, sediment transport and protection effects are factored in, as well as a variable discharge. We show that the stream power law model might still be a valid model but that as soon as realistic effects are included such as a threshold for sediment transport, variable discharge and dynamic width the resulting exponents m and n can be as high as 2 and 4. This high non-linearity has a profound consequence on the sensitivity of fluvial relief to incision rate. We also show that additional complexity does not systematically translates into more non-linear behaviour. For instance, considering only a dynamical width

  8. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA in a Mexican Population

    Directory of Open Access Journals (Sweden)

    María Fernanda Bernal-Orozco

    2018-04-01

    Full Text Available Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy or 1 (healthy, and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016, were invited to participate. The survey was administered in two rounds (test and retest with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC, and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant. The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001, and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885. It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  9. Paradigm shifts in orthodontic treatment with mini-implant anchorage

    Directory of Open Access Journals (Sweden)

    Johnny Joung-Lin Liaw

    2015-01-01

    Full Text Available After the applications of mini-implant anchorage, the envelope of orthodontic treatment was expanded and some treatment modes were changed because of more predictable tooth movement with empowered anchorage. The author tried to share his experience of TADs applications for clarifying the paradigm shifts of orthodontic treatment assisted with the mini-implant anchorage.

  10. Mini implants for definitive prosthodontic treatment: a systematic review.

    Science.gov (United States)

    Bidra, Avinash S; Almas, Khalid

    2013-03-01

    Mini implants are commonly used in orthodontics and for interim prosthodontic treatment, but evidence for their use in definitive prosthodontic treatment is not clear. This systematic review evaluated the mini-implant literature to analyze short-term (1 to 5 years), medium-term (5 to 10 years), and long-term (beyond 10 years) survival rates when used for definitive prosthodontic treatment. An electronic search of the English language literature for articles published between January 1974 and May 2012 was performed by using PubMed and Cochrane databases with predetermined inclusion criteria. Key terms included in the search were mini dental implants, narrow diameter implants, reduced diameter implants, small diameter implants, transitional implants, interim implants, and provisional implants. After a systematic filtering process, the selected articles were subjected to a detailed review, and the data collected were used to calculate the 1-year interval survival rate (ISR) and the cumulative survival rate (CSR). The electronic database search yielded 1807 titles. By scrutinizing the titles and abstracts with inclusion and exclusion criteria, the researchers identified 9 studies of mini implants for definitive prosthodontic treatment. Of the studies identified, 1 was a randomized controlled trial, 2 were prospective studies, and 6 were retrospective studies. The majority of mini implants were placed by using a flapless surgical technique in the mandibular anterior region to support an overdenture. The 1st year ISR was 94.7% and the CSR over a 9-year period, primarily attributed to data from 1 study, was 92.2%. Most implants were immediately loaded and almost all implant failures occurred during the first year after implant placement. For short-term survival, the first year ISR of 94.7% of mini dental implants appears encouraging, but the true 1-year survival rate is unknown, as the minimum follow-up period reported for several implants was less than a year

  11. Mini-Sniffer III on Lakebed with Ground Support Crew

    Science.gov (United States)

    1976-01-01

    The third version of the Mini-Sniffer remotely-piloted research vehicle on Rogers Dry Lake, adjacent to NASA's Dryden Flight Research Center, Edwards, California. The futuristic-looking ground crew are in white, self-contained suits, because the engine on this third version of the Mini-Sniffer was powered by hydrazine, which is a very hazardous material. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the

  12. European Hernia Society guidelines on the closure of abdominal wall incisions

    DEFF Research Database (Denmark)

    Muysoms, F E; Antoniou, S A; Bury, K

    2015-01-01

    using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II...... of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method......, it is suggested using the smallest trocar size adequate for the procedure and closure of the fascial defect if trocars larger or equal to 10 mm are used. For single incision laparoscopic surgery, we suggest meticulous closure of the fascial incision to avoid an increased risk of incisional hernias....

  13. The influence of lip form on incisal display with lips in repose on the esthetic preferences of dentists and lay people.

    Science.gov (United States)

    Kim, Jee; Topolski, Richard; Dickinson, Douglas; Ramos, Van

    2017-09-01

    Information is lacking for viewer preferences for incisal display with lips in repose. The purpose of this online survey was to establish measurement parameters to classify and define a lip form and to evaluate the influence of lip form on dentists' and laypersons' preferences for the amount of incisal display with lips in repose. Computer-generated male and female models were created using 3 different lip forms each, straight, moderate, and high. Three images of these models (frontal full face, zoomed-in frontal around the mouth, and oblique zoomed-in image of the mouth) were arranged in an interactive survey that was disseminated on the Websites Facebook, Instagram, DentalTown and by word-of-mouth. Respondents manipulated the incisal display of all 3 images in unison, using a slide bar, and the resulting incisal display was measured in millimeters and served as the primary dependent measure. Survey demographic data were obtained from an online survey site. Data were assessed for skewness, kurtosis, and outliers and analyzed with 5-way ANOVA: 2 sex levels for model, 2 levels for sex of respondent, 3 levels for lip height, 3 levels for occupation, and 5 levels of ethnicity, with multiple comparisons corrected with Bonferroni adjustments and post hoc comparisons performed using the Scheffé test (α=.05 for all comparisons). A total of 1039 individuals consented to the study. A final sample size of 687 respondents was obtained after excluding 352 who failed to complete the survey. The results indicated that lip form affected the esthetic perception of incisal display significantly (P<.001), with a preference for a greater amount of incisal display corresponding with increasing lip forms. Sex of the model was also significant, with greater incisal display being preferred for female faces. A significant difference was found for respondents' ethnicity, with African Americans generally preferring smaller incisal displays than other ethnic groups. No other main effects

  14. [EFFECTIVENESS OF ADVANCED SKIN FLAP AND V-SHAPED VENTRAL INCISION ALONG THE ROOT OF PENILE SHAFT FOR CONCEALED PENIS].

    Science.gov (United States)

    Lin, Junshan; Li, Dumiao; Zhang, Jianxing; Wu, Qiang; Xu, Yali; Lin, Li

    2015-09-01

    To investigate effectiveness of advanced skin flap and V-shaped ventral incision along the root of penile shaft for concealed penis in children. Between July 2007 and January 2015, 121 boys with concealed penis were treated with advanced skin flap and V-shaped ventral incision along the root of penile shaft. The age varied from 18 months to 13 years (mean, 7.2 years). Repair was based on a vertical incision in median raphe, complete degloving of penis and tacking its base to the dermis of the skin. Advanced skin flap and a V-shaped ventral incision along the root of penile shaft were used to cover the penile shaft. The operation time ranged from 60 to 100 minutes (mean, 75 minutes). Disruption of wound occurred in 1 case, and was cured after dressing change; and primary healing of incision was obtained in the others. The follow-up period ranged from 3 months to 7 years (median, 24 months). All patients achieved good to excellent cosmetic results with a low incidence of complications. The results were satisfactory in exposure of penis and prepuce appearance. No obvious scar was observed. The penis had similar appearance to that after prepuce circumcision. A combination of advanced skin flap and V-shaped ventral incision along the root of penile shaft is a simple, safe, and effective procedure for concealed penis with a similar appearance result to the prepuce circumcision.

  15. Incisive papilla and positions of maxillary anterior teeth among ...

    African Journals Online (AJOL)

    Results: One hundred and twelve maxillary casts generated from participants aged 18-35 years (mean age 22.39±2.00 years), with well aligned arches were studied. The maxillary central incisor exhibited a mean of 14.93±1.52mm from the posterior limit of the incisive papilla while the inter-canine line scored a mean of ...

  16. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Science.gov (United States)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement

  17. Recommended safety objectives, principles and requirements for mini-reactors

    International Nuclear Information System (INIS)

    1991-05-01

    Canadian and international publications containing objectives, principles and requirements for the safety of nuclear facilities in general and nuclear power plants in particular have been reviewed for their relevance to mini-reactors. Most of the individual recommendations, sometimes with minor wording changes, are applicable to mini-reactors. However, some prescriptive requirements for the shutdown, emergency core cooling and containment systems of power reactors are considered inappropriate for mini-reactors. The Advisory Committee on Nuclear Safety favours a generally non-prescriptive approach whereby the applicant for a mini-reactor license is free to propose any means of satisfying the fundamental objectives, but must convince the regulatory agency to that effect. To do so, a probabilistic safety assessment (PSA) would be the favoured procedure. A generic PSA for all mini-reactors of the same design would be acceptable. Notwithstanding this non-prescriptive approach, the ACNS considers that it would be prudent to require the existence of at least one independent shutdown system and two physically independent locations from which the reactor can be shut down and the shutdown condition monitored, and to require provision for an assumed loss of integrity of the primary cooling system's boundary unless convincing arguments to the contrary are presented. The ACNS endorses in general the objectives and fundamental principles proposed by the interorganizational Small Reactor Criteria working group, and intends to review and comment on the documents on specific applications to be issued by that working group

  18. Cryopreservation of boar semen in mini- and maxi-straws.

    Science.gov (United States)

    Bwanga, C O; de Braganca, M M; Einarsson, S; Rodriguez-Martinez, H

    1990-10-01

    Split ejaculates from four boars were frozen with a programmable freezing machine, in mini- (0.25 ml) and maxi- (5 ml) plastic straws with an extender at either acidic (6.3) or alkaline (7.4) pH. Glycerol (3%) was used as cryoprotectant. The freezing of the semen was monitored by way of thermocouples placed in the straws. Post-thaw motility and acrosome integrity were evaluated; the latter using phase contrast microscopy, eosin-nigrosin stain and electron microscopy. Post-thaw sperm motility was significantly higher when semen was frozen in mini-straws than in maxi-straws. For the mini-straws, the motility was better when semen was exposed to an acidic environment during freezing, but this beneficial effect of the low extracellular pH was not evident when maxi-straws were thawed. The motility of the spermatozoa diminished significantly during the thermoresistance test (0 h and 2 h time) at 37 degrees C in a similar way for both straws and extracellular pH's. The freezing procedure, no matter the extracellular pH, did not cause major acrosomal damages, but significantly more normal apical ridges were present in the mini-straws than in the maxi-straws. This in vitro evaluation indicated that the freezing method employed was better for mini- than for maxi-straws since the freezing of the 5 ml volumes was not homogeneous, due to the large section area between the surface and the core of the straw.

  19. A mini-microscope for in situ monitoring of cells†‡

    Science.gov (United States)

    Kim, Sang Bok; Koo, Kyo-in; Bae, Hojae; Dokmeci, Mehmet R.; Hamilton, Geraldine A.; Bahinski, Anthony; Kim, Sun Min; Ingber, Donald E.

    2013-01-01

    A mini-microscope was developed for in situ monitoring of cells by modifying off-the-shelf components of a commercial webcam. The mini-microscope consists of a CMOS imaging module, a small plastic lens and a white LED illumination source. The CMOS imaging module was connected to a laptop computer through a USB port for image acquisition and analysis. Due to its compact size, 8 × 10 × 9 cm, the present microscope is portable and can easily fit inside a conventional incubator, and enables real-time monitoring of cellular behaviour. Moreover, the mini-microscope can be used for imaging cells in conventional cell culture flasks, such as Petri dishes and multi-well plates. To demonstrate the operation of the mini-microscope, we monitored the cellular migration of mouse 3T3 fibroblasts in a scratch assay in medium containing three different concentrations of fetal bovine serum (5, 10, and 20%) and demonstrated differential responses depending on serum levels. In addition, we seeded embryonic stem cells inside poly(ethylene glycol) microwells and monitored the formation of stem cell aggregates in real time using the mini-microscope. Furthermore, we also combined a lab-on-a-chip microfluidic device for microdroplet generation and analysis with the mini-microscope and observed the formation of droplets under different flow conditions. Given its cost effectiveness, robust imaging and portability, the presented platform may be useful for a range of applications for real-time cellular imaging using lab-on-a-chip devices at low cost. PMID:22911426

  20. Impact of Mini-drone based Video Surveillance on Invasion of Privacy

    OpenAIRE

    Korshunov, Pavel; Bonetto, Margherita; Ebrahimi, Touradj; Ramponi, Giovanni

    2015-01-01

    An increase in adoption of video surveillance, affecting many aspects of daily lives, raises public concern about an intrusion into individual privacy. New sensing and surveillance technologies, such as mini-drones, threaten to eradicate boundaries of private space even more. Therefore, it is important to study the effect of mini-drones on privacy intrusion and to understand how existing protection privacy filters perform on a video captured by a mini-drone. To this end, we have built a publi...

  1. NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE

    Directory of Open Access Journals (Sweden)

    Tukiran Surbakti

    2016-03-01

    Full Text Available Abstract NEUTRONICS ANALYSIS ON MINI TEST FUEL IN THE RSG-GAS CORE. Research of UMo fuel for research reactor has been developing  right now. The fuel of  research reactor used is uranium low enrichment with high density. For supporting the development of fuel, an assessment of mini fuel in the RSG-GAS core was performed. The mini fuel are U7Mo-Al and U6Zr-Al with densitis of 7.0gU/cc and 5.2 gU/cc, respectively. The size of both fuel are the same namely 630x70.75x1.30 mm were inserted to the 3 plates of dummy fuel. Before being irradiated in the core, a calculation for safety analysis  from neutronics and thermohydrolics aspects were required. However, in this paper will discuss safety analysis of the U7Mo-Al and U6Zr-Al mini fuels from neutronic point of view.  The calculation was done using WIMSD-5B and Batan-3DIFF code. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. Power density of U7Mo-Al mini fuel bigger than U6Zr-Al fuel.   Key words: mini fuel, neutronics analysis, reactor core, safety analysis   Abstrak ANALISIS NEUTRONIK ELEMEN BAKAR UJI MINI DI TERAS RSG-GAS. Penelitian tentang bahan bakar UMo untuk reaktor riset terus berkembang saat ini. Bahan bakar reaktor riset yang digunakan adalah uranium pengkayaan rendah namun densitas tinggi.  Untuk mendukung pengembangan bahan bakar dilakukan uji elemen bakar mini di teras reakror RSG-GAS dengan tujuan menentukan jumlah siklus di dalam teras sehingga tercapai fraksi bakar maksimum. Bahan bakar yang diuji adalah U7Mo-Al dengan densitas 7,0 gU/cc dan U6Zr-Al densitas 5,2 gU/cc. Ukuran kedua bahan bakar uji tersebut adalah sama 630x70,75x1,30 mm dimasukkan masing masing kedalam 3 pelat dummy bahan bakar. Sebelum diiradiasi ke dalam teras reaktor maka perlu dilakukan perhitungan keselamatan baik secara neutronik maupun termohidrolik. Dalam makalah ini

  2. Anterograde axonal transport and intercellular transfer of WGA-HRP in trigeminal-innervated sensory receptors of rat incisive papilla.

    Science.gov (United States)

    Chan, K Y; Byers, M R

    1985-04-08

    The ultrastructure and identification of WGA-HRP-labeled sensory receptors in the rat incisive papilla (the most anterior part of hard palate) were studied using semiserial thin sections. Various sensory receptors were organized according to three locations: dome region (ventral), chemosensory corpuscle region (medial to orifice of incisive canal), and lateral labium (apposing the incisive canal). In the dome region, the sensory receptors were localized in three sensory zones that were associated with surface ridges (one medial and two lateral). In each of these zones, intraepithelial receptor axons and Merkel receptors occurred in the epithelium, while simple unencapsulated corpuscles, glomerular-Meissner corpuscles, and incisive (encapsulated) corpuscles occurred in the lamina propria. In the chemosensory corpuscle region, chemosensory corpuscles and intraepithelial receptor axons were located in the epithelium, and incisive corpuscles were present in the lamina propria. In the lateral labium, only intraepithelial receptor axons were prominent. In all these sensory receptors, the preterminal axons and axon terminals were labeled with the tracer protein. In addition, some nonneuronal cells closely associated with the axon terminals were selectively labeled, e.g., terminal Schwann cells, lamellar Schwann cells, Merkel cells, corpuscular basal cells and chemosensory cells. Other adjacent cells were not labeled, e.g., unspecialized epithelial cells, capsular cells, corpuscular sustentacular cells, and fibroblasts. In both labeled axons and cells, WGA-HRP was incorporated into vesicles, tubules, and vacuolar organelles. The specific intercellular transfer of tracer protein may indicate trophic interactions between axon terminals and support cells in sensory receptors. The specific organization of multiple sensory receptors in the rat incisive papilla may provide a useful alternative system for studying somatosensory physiology.

  3. Distinction of infected and non-infected post-surgical incisions with In-111-WBC scintigraphy

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.; Hinkle, G.H.; Olsen, J.O.

    1985-01-01

    To determine if In-111-WBCs scintigraphy can distinguish between healing and infection in post-surgical wounds, a prospective study was performed in patients with 3-14 day old surgical incisions. Eighteen patients (11 males and 7 females) were scanned 24 hrs after injection of 0.5 mCi of In-111 labeled autologous leukocytes. The scan findings were correlated with blood and/wound cultures results and diagnosis at time of discharge. Incisional uptake of In-111-WBCs was noted in 9 patients with infected surgical wounds and was absent in those 9 patients with non-infected surgical wounds. The results of the authors' study show that In-111-WBCs do not accumulate in non-infected surgical incisions. This confirms their previous findings in rats. The high specificity of In-111 leukocytes imaging makes it a valuable study in the evaluation of post-operative patients with suspected surgical wound infections. In-111 WBCs scintigraphy can distinguish between normal healing and infection at the site of recent (3-14 days) surgical incisions

  4. A DNA Mini-Barcoding System for Authentication of Processed Fish Products.

    Science.gov (United States)

    Shokralla, Shadi; Hellberg, Rosalee S; Handy, Sara M; King, Ian; Hajibabaei, Mehrdad

    2015-10-30

    Species substitution is a form of seafood fraud for the purpose of economic gain. DNA barcoding utilizes species-specific DNA sequence information for specimen identification. Previous work has established the usability of short DNA sequences-mini-barcodes-for identification of specimens harboring degraded DNA. This study aims at establishing a DNA mini-barcoding system for all fish species commonly used in processed fish products in North America. Six mini-barcode primer pairs targeting short (127-314 bp) fragments of the cytochrome c oxidase I (CO1) DNA barcode region were developed by examining over 8,000 DNA barcodes from species in the U.S. Food and Drug Administration (FDA) Seafood List. The mini-barcode primer pairs were then tested against 44 processed fish products representing a range of species and product types. Of the 44 products, 41 (93.2%) could be identified at the species or genus level. The greatest mini-barcoding success rate found with an individual primer pair was 88.6% compared to 20.5% success rate achieved by the full-length DNA barcode primers. Overall, this study presents a mini-barcoding system that can be used to identify a wide range of fish species in commercial products and may be utilized in high throughput DNA sequencing for authentication of heavily processed fish products.

  5. Mini mental state examination

    DEFF Research Database (Denmark)

    Kørner, Ejnar Alex; Lauritzen, Lise; Wang, August

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...... the severity of dementia disorders. Udgivelsesdato: 2008-Feb-25...

  6. Implementing the undergraduate mini-CEX: a tailored approach at Southampton University.

    Science.gov (United States)

    Hill, Faith; Kendall, Kathleen; Galbraith, Kevin; Crossley, Jim

    2009-04-01

    The mini-clinical evaluation exercise (mini-CEX) is widely used in the UK to assess clinical competence, but there is little evidence regarding its implementation in the undergraduate setting. This study aimed to estimate the validity and reliability of the undergraduate mini-CEX and discuss the challenges involved in its implementation. A total of 3499 mini-CEX forms were completed. Validity was assessed by estimating associations between mini-CEX score and a number of external variables, examining the internal structure of the instrument, checking competency domain response rates and profiles against expectations, and by qualitative evaluation of stakeholder interviews. Reliability was evaluated by overall reliability coefficient (R), estimation of the standard error of measurement (SEM), and from stakeholders' perceptions. Variance component analysis examined the contribution of relevant factors to students' scores. Validity was threatened by various confounding variables, including: examiner status; case complexity; attachment specialty; patient gender, and case focus. Factor analysis suggested that competency domains reflect a single latent variable. Maximum reliability can be achieved by aggregating scores over 15 encounters (R = 0.73; 95% confidence interval [CI] +/- 0.28 based on a 6-point assessment scale). Examiner stringency contributed 29% of score variation and student attachment aptitude 13%. Stakeholder interviews revealed staff development needs but the majority perceived the mini-CEX as more reliable and valid than the previous long case. The mini-CEX has good overall utility for assessing aspects of the clinical encounter in an undergraduate setting. Strengths include fidelity, wide sampling, perceived validity, and formative observation and feedback. Reliability is limited by variable examiner stringency, and validity by confounding variables, but these should be viewed within the context of overall assessment strategies.

  7. A high-resolution mini-microscope system for wireless real-time monitoring.

    Science.gov (United States)

    Wang, Zongjie; Boddeda, Akash; Parker, Benjamin; Samanipour, Roya; Ghosh, Sanjoy; Menard, Frederic; Kim, Keekyoung

    2017-09-04

    Compact, cost-effective and high-performance microscope that enables the real-time imaging of cells and lab-on-a-chip devices is highly demanded for cell biology and biomedical engineering. This paper aims to present the design and application of an inexpensive wireless mini-microscope with resolution up to 2592 × 1944 pixels and speed up to 90 fps. The mini-microscope system was built on a commercial embedded system (Raspberry Pi). We modified a camera module and adopted an inverse dual lens system to obtain the clear field of view and appropriate magnification for tens of micrometer objects. The system was capable of capturing time-lapse images and transferring image data wirelessly. The entire system can be operated wirelessly and cordlessly in a conventional cell culturing incubator. The developed mini-microscope was used to monitor the attachment and proliferation of NIH-3T3 and HEK 293 cells inside an incubator for 50 hours. In addition, the mini-microscope was used to monitor a droplet generation process in a microfluidic device. The high-quality images captured by the mini-microscope enabled us an automated analysis of experimental parameters. The successful applications prove the great potential of the developed mini-microscope for monitoring various biological samples and microfluidic devices. This paper presents the design of a high resolution mini-microscope system that enables the wireless real-time imaging of cells inside the incubator. This system has been verified to be a useful tool to obtain high-quality images and videos for the automated quantitative analysis of biological samples and lab-on-a-chip devices in the long term.

  8. PARTICIPATION OF MINI-BASKETBALL PLAYERS DURING SMALL-SIDED COMPETITIONS

    Directory of Open Access Journals (Sweden)

    M\\u00AA Isabel Pi\\u00F1ar

    2009-01-01

    Full Text Available This study presents the differences of competition between mini-basketball with the traditional rules (5-a-side and minibasket with rule modifications (3-a-side such as: reduced number of players on court, compulsory participation in 2 of the match's 4 periods, reduced court size, placing the free throw line at 3m from the basket, and including a three-point line. The sample that was selected included 47 mini-basketball players, and the study was carried out using a quasi-experimental design without a control group. The aim was to determine the effect of rule modifications on the participation of the player with the ball. It was demonstrated that the degree of individual participation is greater in mini-basketball with modified rules.

  9. Two mini-preparation protocols to DNA extraction from plants with ...

    African Journals Online (AJOL)

    Were standardized two previously reported standard plant DNA extraction methods, but improved them on mini preparations to use the samples for population genetic analysis. The combination of CTAB lysis procedure-solvent extraction and DNA column purification (DNeasy plant mini kit modification) enables a faster and ...

  10. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions.

    Science.gov (United States)

    Kim, Sue Min; Cook, Kyung Hoon; Lee, Il Jae; Park, Dong Ha; Park, Myong Chul

    2017-04-01

    In our hospital, an adverse event reporting system was initiated that alerts the plastic surgery department immediately after suspecting contrast media extravasation injury. This system is particularly important for a large volume of extravasation during power injector use. Between March 2011 and May 2015, a retrospective chart review was performed on all patients experiencing contrast media extravasation while being treated at our hospital. Immediate treatment by squeezing with multiple slit incisions was conducted for a portion of these patients. Eighty cases of extravasation were reported from approximately 218 000 computed tomography scans. The expected extravasation volume was larger than 50 ml, or severe pressure was felt on the affected limb in 23 patients. They were treated with multiple slit incisions followed by squeezing. Oedema of the affected limb disappeared after 1-2 hours after treatment, and the skin incisions healed within a week. We propose a set of guidelines for the initial management of contrast media extravasation injuries for a timely intervention. For large-volume extravasation cases, immediate management with multiple slit incisions is safe and effective in reducing the swelling quickly, preventing patient discomfort and decreasing skin and soft tissue problems. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  11. High-flying Mini-Sniffer RPV - Mars bound

    Science.gov (United States)

    Reed, R. D.

    1978-01-01

    The Mini-Sniffer is a small unmanned survey aircraft developed by NASA to conduct turbulence and atmospheric pollution measurements from ground level to an altitude of 90,000 ft. Carrying a 25-lb air sampling apparatus, the Mini-Sniffer typically cruises for one hour at 70,000 ft before being remotely piloted back to earth. A hydrazine monopropellant engine powers the craft, while a PCM telemetering system and a radar transponder provide control functions. Development of a high-performance low-Reynolds-number airfoil could make the research craft suitable for a low-altitude terrain-following mission on Mars.

  12. The Mini-Social Phobia Inventory: psychometric properties in an adolescent general population sample.

    Science.gov (United States)

    Ranta, Klaus; Kaltiala-Heino, Riittakerttu; Rantanen, Päivi; Marttunen, Mauri

    2012-07-01

    Onset of social phobia (SP) typically occurs in adolescence. Short screening instruments for its assessment are needed for use in primary health and school settings. The 3-item Mini-Social Phobia Inventory (SPIN) has demonstrated effectiveness in screening for generalized SP (GSP) in adults. This study examined the psychometrics of the Mini-SPIN in an adolescent general population sample. Three hundred fifty adolescents aged 12 to 17 years were clinically interviewed using the Schedule for Affective Disorders and Schizophrenia for School-Age Children-Present and Lifetime Version for identification of SP and other Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Axis I disorders, blind to their Mini-SPIN status. Associations between SP; subclinical SP; other anxiety, depressive, and disruptive disorders; and Mini-SPIN scores were examined, and diagnostic efficiency statistics were calculated. The association between Mini-SPIN scores and the generalized subtype of SP was also examined. As in adults, the Mini-SPIN items differentiated subjects with SP from those without. A score of 6 points or greater was found optimal in predicting SP with a sensitivity of 86%, specificity of 84%, and positive and negative predictive values of 26% and 99%. The Mini-SPIN also possessed discriminative validity, as scores were higher for adolescents with SP than they were for those with depressive, disruptive, and other anxiety disorders. The Mini-SPIN was also able to differentiate adolescents with GSP from the rest of the sample. The Mini-SPIN has good psychometrics for screening SP in adolescents from general population and may have value in screening for GSP. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Tourette Syndrome: A Mini-Review

    Directory of Open Access Journals (Sweden)

    Michal Novotny

    2018-03-01

    Full Text Available The purpose of this mini-review is to provide the latest information on epidemiology, pathophysiology, diagnosis, and treatment of Tourette syndrome (TS. The authors conducted a literature search of available sources describing the issue of tic disorders with special focus on TS and made a comparison and evaluation of relevant findings. The results of this mini-review indicate that TS is a complex disorder, which has a significant impact on the quality of life of both the patients and his/her family. Therefore, early and proper diagnosis and treatment are necessary in order to reduce or even eliminate both symptoms and social burden of the patient. This requires a multidisciplinary management approach in order to meet the patients’ special needs. Future research should focus on neuroimaging, new neurotransmitter targets, in functional neurosurgery, as well as the effect of non-pharmacological psychotherapies for these people.

  14. Postcataract endophthalmitis prophylaxis using irrigation, incision hydration, and eye pressurization with vancomycin

    Directory of Open Access Journals (Sweden)

    Schelonka LP

    2015-07-01

    Full Text Available Lee P Schelonka,1 Margaret A SaBell2 1Department of Opthalmology, Kaiser Permanente Lone Tree Medical Offices, Lone Tree, 2Department of Infection Control, Kaiser Permanente Lone Tree Medical Offices, Lone Tree, Denver, CO, USA Purpose: This study aimed to determine whether switching from balanced salt solution (BSS to vancomycin 20 g/mL BSS for incision hydration and eye pressurization reduces the rate of postcataract endophthalmitis.Methods: This was a patient safety/quality improvement project, including all patients undergoing cataract surgery at the Kaiser Permanente Colorado Ophthalmology Department from January 2002 to December 2014. Throughout the study, patients received vancomycin 20 µg/mL in the irrigating solution. During the baseline period from 2002 to 2005, surgeons pressurized eyes and hydrated incisions with plain BSS. During the intervention period from 2006 through 2014, surgeons switched from BSS to the vancomycin/BSS irrigating solution for eye pressurization and incision hydration.Results: A total of 57,263 cataract operations were performed by 24 surgeons at seven surgical centers: 12,400 in the baseline period and 44,863 in the intervention period. The rate of postcataract endophthalmitis declined significantly from 5/12,400 (rate: 0.4/1,000 in the baseline period to 1/44,863 (rate: 0.022/1,000 during the intervention period (odds ratio [OR]: 18.1, 95% confidence interval [CI]: 2.11–154.9; χ2=13.5, P=0.00024. Accounting for an estimated 2.05-fold risk reduction due to confounding variables, the risk reduction attributed to the intervention remained significant: (adjusted OR: 8.78, 95% CI: 1.73–44.5; χ2=10.06, P=0.0015. Since 2009, we have not experienced any cases of postcataract endophthalmitis after 32,753 operations.Conclusion: We experienced a significant reduction in postcataract endophthalmitis when we switched from BSS to the vancomycin/BSS irrigating solution for incision hydration and eye pressurization

  15. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC) among a heterogeneous sample of long-term cancer survivors: a cross-sectional study.

    Science.gov (United States)

    Zucca, Alison; Lambert, Sylvie D; Boyes, Allison W; Pallant, Julie F

    2012-05-20

    The mini-Mental Adjustment to Cancer Scale (mini-MAC) is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. RUMM 2030 was used to analyse the mini-MAC data (n=851). Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI), response format, local dependency, targeting, item bias (or differential item functioning -DIF), and dimensionality. For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales - Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of adaptive and maladaptive coping, extensive modifications were

  16. Rasch analysis of the Mini-Mental Adjustment to Cancer Scale (mini-MAC among a heterogeneous sample of long-term cancer survivors: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Zucca Alison

    2012-05-01

    Full Text Available Abstract Background The mini-Mental Adjustment to Cancer Scale (mini-MAC is a well-recognised, popular measure of coping in psycho-oncology and assesses five cancer-specific coping strategies. It has been suggested that these five subscales could be grouped to form the over-arching adaptive and maladptive coping subscales to facilitate the interpretation and clinical application of the scale. Despite the popularity of the mini-MAC, few studies have examined its psychometric properties among long-term cancer survivors, and further validation of the mini-MAC is needed to substantiate its use with the growing population of survivors. Therefore, this study examined the psychometric properties and dimensionality of the mini-MAC in a sample of long-term cancer survivors using Rasch analysis. Methods RUMM 2030 was used to analyse the mini-MAC data (n=851. Separate Rasch analyses were conducted for each of the original mini-MAC subscales as well as the over-arching adaptive and maladaptive coping subscales to examine summary and individual model fit statistics, person separation index (PSI, response format, local dependency, targeting, item bias (or differential item functioning -DIF, and dimensionality. Results For the fighting spirit, fatalism, and helplessness-hopelessness subscales, a revised three-point response format seemed more optimal than the original four-point response. To achieve model fit, items were deleted from four of the five subscales – Anxious Preoccupation items 7, 25, and 29; Cognitive Avoidance items 11 and 17; Fighting Spirit item 18; and Helplessness-Hopelessness items 16 and 20. For those subscales with sufficient items, analyses supported unidimensionality. Combining items to form the adaptive and maladaptive subscales was partially supported. Conclusions The original five subscales required item deletion and/or rescaling to improve goodness of fit to the Rasch model. While evidence was found for overarching subscales of

  17. A preliminary study of the mini-mental state examination in a Spanish child population.

    Science.gov (United States)

    Rubial-Alvarez, Sandra; Machado, María-Clara; Sintas, Elena; de Sola, Susana; Böhm, Peter; Peña-Casanova, Jordi

    2007-11-01

    The Mini-Mental State Examination is one of the most widely used screening tests for the adult population in daily neurologic practice. The aim of this study was to describe and to analyze the results of the Mini-Mental State Examination administered to Spanish children and to assess the relationship between Mini-Mental State Examination scores and the child's mental age/intelligence quotient. The study population included 181 children whose ages ranged between 4 and 12 years. The neuropsychologic battery consisted of the Mini-Mental State Examination and Kaufman Brief Intelligence Test. Percentiles were obtained for the Mini-Mental State Examination total score according to age ranges. Performance gradually increased from 4 to 10 years of age when a plateau in the total Mini-Mental State Examination score was reached. At the age of 6 years, results exceeded 24 on average. Pairwise mean comparisons showed statistically significant differences between the age groups (P Mini-Mental State Examination score correlated significantly with the child's chronologic (r = 0.80, P mental (r = 0.76, P Mini-Mental State Examination in a Spanish child population as well as a first step for the assessment of the usefulness of this instrument as a cognitive screening tool for children's development.

  18. Satisfaction, function and repair integrity after arthroscopic versus mini-open rotator cuff repair.

    Science.gov (United States)

    Barnes, L A Fink; Kim, H M; Caldwell, J-M; Buza, J; Ahmad, C S; Bigliani, L U; Levine, W N

    2017-02-01

    Advances in arthroscopic techniques for rotator cuff repair have made the mini-open approach less popular. However, the mini-open approach remains an important technique for repair for many surgeons. The aims of this study were to compare the integrity of the repair, the function of the shoulder and satisfaction post-operatively using these two techniques in patients aged > 50 years. We identified 22 patients treated with mini-open and 128 patients treated with arthroscopic rotator cuff repair of July 2007 and June 2011. The mean follow-up was two years (1 to 5). Outcome was assessed using the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) scores, and satisfaction. The integrity of the repair was assessed using ultrasonography. A power analysis ensured sufficient enrolment. There was no statistically significant difference between the age, function, satisfaction, or pain scores (p > 0.05) of the two groups. The integrity of the repair and the mean SST scores were significantly better in the mini-open group (91% of mini-open repairs were intact versus 60% of arthroscopic repairs, p = 0.023; mean SST score 10.9 (standard deviation (sd) 1.3) in the mini-open group; 8.9 (sd 3.5) in arthroscopic group; p = 0.003). The ASES scores were also higher in the mini-open group (mean ASES score 91.0 (sd 10.5) in mini-open group; mean 82.70 (sd 19.8) in the arthroscopic group; p = 0.048). The integrity of the repair and function of the shoulder were better after a mini-open repair than after arthroscopic repair of a rotator cuff tear in these patients. The functional difference did not translate into a difference in satisfaction. Mini-open rotator cuff repair remains a useful technique despite advances in arthroscopy. Cite this article: Bone Joint J 2017;99-B:245-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  19. Signatures of Late Pleistocene fluvial incision in an Alpine landscape

    Science.gov (United States)

    Leith, Kerry; Fox, Matthew; Moore, Jeffrey R.

    2018-02-01

    Uncertainty regarding the relative efficacy of fluvial and glacial erosion has hindered attempts to quantitatively analyse the Pleistocene evolution of alpine landscapes. Here we show that the morphology of major tributaries of the Rhone River, Switzerland, is consistent with that predicted for a landscape shaped primarily by multiple phases of fluvial incision following a period of intense glacial erosion after the mid-Pleistocene transition (∼0.7 Ma). This is despite major ice sheets reoccupying the region during cold intervals since the mid-Pleistocene. We use high-resolution LiDAR data to identify a series of convex reaches within the long-profiles of 18 tributary channels. We propose these reaches represent knickpoints, which developed as regional uplift raised tributary bedrock channels above the local fluvial baselevel during glacial intervals, and migrated upstream as the fluvial system was re-established during interglacial periods. Using a combination of integral long-profile analysis and stream-power modelling, we find that the locations of ∼80% of knickpoints in our study region are consistent with that predicted for a fluvial origin, while the mean residual error over ∼100 km of modelled channels is just 26.3 m. Breaks in cross-valley profiles project toward the elevation of former end-of-interglacial channel elevations, supporting our model results. Calculated long-term uplift rates are within ∼15% of present-day measurements, while modelled rates of bedrock incision range from ∼1 mm/yr for low gradient reaches between knickpoints to ∼6-10 mm/yr close to retreating knickpoints, typical of observed rates in alpine settings. Together, our results reveal approximately 800 m of regional uplift, river incision, and hillslope erosion in the lower half of each tributary catchment since 0.7 Ma.

  20. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Perevalov, Denis [Univ. of Alabama, Tuscaloosa, AL (United States)

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for vμ → ve neutrino oscillations at Δm2 ~ 1 eV2 using an intense neutrino flux with an average energy Ev ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current π0, charged current quasi-elastic (CCQE), charged current π+, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis

  1. Review of Strategies and Technologies for Demand-Side Management on Isolated Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Harper, Meg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-03-01

    This review provides an overview of strategies and currently available technologies used for demandside management (DSM) on mini-grids throughout the world. For the purposes of this review, mini-grids are defined as village-scale electricity distribution systems powered by small local generation sources and not connected to a main grid.1 Mini-grids range in size from less than 1 kW to several hundred kW of installed generation capacity and may utilize different generation technologies, such as micro-hydro, biomass gasification, solar, wind, diesel generators, or a hybrid combination of any of these. This review will primarily refer to AC mini-grids, though much of the discussion could apply to DC grids as well. Many mini-grids include energy storage, though some rely solely on real-time generation.

  2. Modelling channel incision and alpine hillslope development using laser altimetry data

    NARCIS (Netherlands)

    Anders, N.S.; Seijmonsbergen, A.C.; Bouten, W.

    2009-01-01

    This paper presents a new approach to simulate drainage basin evolution and demonstrates that high resolution elevation data can be used as useful tool for a dynamic simulation of Alpine landscape development, in which channel incision is incorporated in high spatial detail. A vector channel

  3. Muscle sparing lateral thoracotomy: the standard incision for thoracic procedures

    Directory of Open Access Journals (Sweden)

    Mihai Dumitrescu

    2017-05-01

    Full Text Available Lateral thoracotomy is a versatile approach with many variations and is currently the most widely used incision in thoracic surgery. In the current article we are presenting the muscle-sparing lateral thoracotomy in the lateral decubitus position which we consider to be the “standard” for lateral thoracotomies. Indications, surgical technique and pitfalls are described alongside our experience with thoracic drainage. Although there is no consensus regarding the name of this incision, some authors call it “axillary thoracotomy” while others call it a “modified lateral thoracotomy”, they all agree on one aspect – the importance of muscle sparing – which makes it the go-to thoracotomy for both small and large procedures involving the lung. Lateral muscle sparing thoracotomy allows for good exposure of the pulmonary hilum, fissures, apex and diaphragm. The approach is easy and quick to perform while at the same time ensuring faster postoperative recovery by sparing the latissimus dorsi muscle, better cosmetics and lower postoperative pain score when compared to the posterolateral or classical lateral thoracotomies.

  4. Pengaruh Permaianan Bola Voli Mini Terhadap Peningkatan Kebugaran Jasmani Pecandu Narkoba

    Directory of Open Access Journals (Sweden)

    Kurnia Rismaningtyas

    2016-10-01

    Full Text Available This study aims to answer the following questions: 1 the influence of a volleyball mini-game model to increase physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. 2 How big contribution volleyball mini model of the game due to the improvement of physical fitness of drug addicts in prisons Women Class II A Semarang in 2015. . T test results obtained tcount for data post test of 2,420 with significance 0.022 <0.05, which means that the average physical fitness between the experimental and control groups after treatment was significantly different. Judging from an average of 35.79 in the experimental group and the control group of 32.92 indicates that the level of physical fitness of women prisoners IIA class drug addict treatment Semarang made a game of volleyball mini-game is better than that do not follow the game of volleyball mini , In the experimental group increased physical fitness significantly, evident from the value t = 6.541 with a significance value of 0.000 <0.05. It was concluded that: 1 Model mini volleyball games that do can improve the physical fitness of inmates in prisons Women Class II A Semarang. 2 In the experimental group showed that the model of a volleyball mini-game has a significant influence on the improvement of physical fitness on female inmates in prison Women drug addicts Class II A Semarang.

  5. Mini-guide til DGNB

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Guiden giver et kort indblik i formålet med de enkelte kriterier i en DGNB- bæredygtighedsvurdering, samt i hvordan der kan måles på kriterierne. Mini-guiden tager afsæt i systemet for certificering af Nybyggede kontor-og erhvervsbyggerier, som er det første og grundlæggende system i DGNB, som al...

  6. Risperidone oral disintegrating mini-tablets: A robust-product for pediatrics

    Directory of Open Access Journals (Sweden)

    El-Say Khalid M.

    2015-12-01

    Full Text Available This study was aimed at developing risperidone oral disintegrating mini-tablets (OD-mini-tablets as age-appropriate formulations and to assess their suitability for infants and pediatric use. An experimental Box-Behnken design was applied to assure high quality of the OD-mini-tablets and reduce product variability. The design was employed to understand the influence of the critical excipient combinations on the production of OD-mini-tablets and thus guarantee the feasibility of obtaining products with dosage form uniformity. The variables selected were mannitol percent in Avicel (X1, swelling pressure of the superdisintegrant (X2, and the surface area of Aerosil as a glidant (X3. Risperidone-excipient compatibilities were investigated using FTIR and the spectra did not display any interaction. Fifteen formulations were prepared and evaluated for preand post-compression characteristics. The prepared ODmini- tablet batches were also assessed for disintegration in simulated salivary fluid (SSF, pH 6.2 and in reconstituted skimmed milk. The optimized formula fulfilled the requirements for crushing strength of 5 kN with minimal friability, disintegration times of 8.4 and 53.7 s in SSF and skimmed milk, respectively. This study therefore proposes the risperidone OD-mini-tablet formula having robust mechanical properties, uniform and precise dosing of medication with short disintegration time suitable for pediatric use.

  7. Vector analysis of high (≥3 diopters) astigmatism correction using small-incision lenticule extraction and laser in situ keratomileusis.

    Science.gov (United States)

    Chan, Tommy C Y; Wang, Yan; Ng, Alex L K; Zhang, Jiamei; Yu, Marco C Y; Jhanji, Vishal; Cheng, George P M

    2018-06-13

    To compare the astigmatic correction in high myopic astigmatism between small-incision lenticule extraction and laser in situ keratomileusis (LASIK) using vector analysis. Hong Kong Laser Eye Center, Hong Kong. Retrospective case series. Patients who had correction of myopic astigmatism of 3.0 diopters (D) or more and had either small-incision lenticule extraction or femtosecond laser-assisted LASIK were included. Only the left eye was included for analysis. Visual and refractive results were presented and compared between groups. The study comprised 105 patients (40 eyes in the small-incision lenticule extraction group and 65 eyes in the femtosecond laser-assisted LASIK group.) The mean preoperative manifest cylinder was -3.42 D ± 0.55 (SD) in the small-incision lenticule extraction group and -3.47 ± 0.49 D in the LASIK group (P = .655). At 3 months, there was no significant between-group difference in uncorrected distance visual acuity (P = .915) and manifest spherical equivalent (P = .145). Ninety percent and 95.4% of eyes were within ± 0.5 D of the attempted cylindrical correction for the small-incision lenticule extraction and LASIK group, respectively (P = .423). Vector analysis showed comparable target-induced astigmatism (P = .709), surgically induced astigmatism vector (P = .449), difference vector (P = .335), and magnitude of error (P = .413) between groups. The absolute angle of error was 1.88 ± 2.25 degrees in the small-incision lenticule extraction group and 1.37 ± 1.58 degrees in the LASIK group (P = .217). Small-incision lenticule extraction offered astigmatic correction comparable to LASIK in eyes with high myopic astigmatism. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Two Late Pleistocene climate-driven incision/aggradation rhythms in the middle Dnieper River basin, west-central Russian Plain

    DEFF Research Database (Denmark)

    Panin, Andrei; Adamiec, Grzegorz; Buylaert, Jan-Pieter

    2017-01-01

    Pleistocene - Holocene climate cycle. The following events were detected. (1) Late MIS 5 - early MIS 4: aggradation of Terrace T1 following the deep incision at the end of MIS 6. (2) Late MIS 4 (40-30 ka): incision into Terrace T1 below the present-day river, formation of the main scarp in the bottom...... of the valley between Terrace T1 and Terrace T0/Floodplain levels. (3) MIS 2: aggradation of Terrace T0, lateral migrations of a shallow braided channel located few meters above the present-day river since ∼25 ka through the LGM. (4) 18-13 ka: incision into Terrace T0 below the modern river. Multiple...

  9. Mini-Exame do Estado Mental: características psicométricas em idosos ambulatoriais Mini-Mental State Examination: psychometric characteristics in elderly outpatients

    Directory of Open Access Journals (Sweden)

    Roberto A Lourenço

    2006-08-01

    Full Text Available OBJETIVO: Avaliar as características de medida do Mini-Exame do Estado Mental em idosos atendidos em um ambulatório geral. MÉTODOS: O total de 303 indivíduos (>65 anos foi submetido à avaliação geriátrica com vários instrumentos, inclusive o Mini-Exame do Estado Mental. Foram calculadas a sensibilidade, a especificidade, os valores preditivos positivo e negativo e a curva ROC. RESULTADOS: A sensibilidade, a especificidade, os valores preditivos positivo e negativo e a área sob a curva ROC foram 80,8%, 65,3%, 44,7%, 90,7% e 0,807, respectivamente (ponto de corte 23/24. O melhor ponto de corte para indivíduos analfabetos foi 18/19 (sensibilidade =73,5%; especificidade =73,9%, e para aqueles com instrução escolar foi 24/25 (sensibilidade =75%; especificidade =69,7%. CONCLUSÕES: Para o rastreamento cognitivo de idosos atendidos em ambulatórios gerais pelo Mini-Exame do Estado Mental, a escolaridade deverá ser considerada para a adoção do ponto de corte mais adequado.OBJECTIVE: To assess the psychometric characteristics of the Mini-Mental State Examination in elderly outpatients who seek primary health care. METHODS: A total of 303 subjects (>65 years underwent comprehensive geriatric assessment with functional tools, including Mini-Mental State Examination. Sensitivity, specificity, positive predictive value, negative predictive value, and ROC curve were calculated. RESULTS: Sensitivity, specificity, positive and negative predictive values, and area under ROC curve were 80.8%, 65.3%, 44.7%, 90.7% and 0.807 respectively (cutoff point =23/24. The best cutoff point for illiterate was 18/19 (sensitivity =73.5%; specificity =73.9%; and for literate was 24/25 (sensitivity =75%; specificity =69.7%. CONCLUSIONS: While screening elderly outpatients for dementia, schooling must be considered in the choice of the best cutoff point in the Mini-Mental State Examination.

  10. Entrepreneur and Establishment of a Mini Hotel in XiChang, China

    OpenAIRE

    Hu, Mingsong

    2013-01-01

    Mini Hotel, is a new hotel will be opened in China in this year. I and 4 of my friends will be the shareholders of this Mini Hotel. The hotel is planned to be operating from the autumn of 2013. Now, everything in this thesis is on process. The main objective of this thesis was to draft an effective approach to ensure this is a right plan which is worth to invest. By using benchmarking and SWOT analysis we defined the strength and weakness of this Mini Hotel business plan. This thesis will ...

  11. [One-stage Operation through the Same Skin Incision for Synchronous Double Primary Breast and Lung Cancer;Report of a Case].

    Science.gov (United States)

    Takahashi, Noriyuki; Kuga, Yoko; Uno, Satoko; Saito, Keita

    2018-02-01

    A 75-year-old woman noticed a small mass in the right side breast and consulted our hospital. The results of the detailed examination indicated the synchronous double primary right breast cancer and the same side lung cancer (rS5). One-stage operation from the same skin incision was scheduled. Volume rendering (VR) of computed tomography (CT)-scan was very useful in deciding the position and the length of the skin incision. The breast tumor resection and the right middle lobe resection were successfully performed through 6.5 cm skin incision.

  12. Model of competitive mini-hotel project life cycle

    OpenAIRE

    Левыкин, Виктор Макарович; Дэвон, Валерия Викторовна

    2014-01-01

    Having examined the situation in the hotel market of the city of Kharkov (Ukraine), it was found that one of the major shortcomings in the activities of mini-hotels is mediocre attitude towards customers, lack of proper attention and poor services. In this regard, there is the need to create a mini-hotel, the most important mission of which would be a genuine concern for guests and their comfort, as well as providing unique services of the highest class.For the success of this mission, it is ...

  13. Lexicography Problems and Theoretical Interpretation of Mini-Dictionaries

    Directory of Open Access Journals (Sweden)

    Jūratė Butkienė

    2011-04-01

    Full Text Available The article deals with principles of the word selection while compiling a mini-dictionary (containing a minimal number of words as well as with criteria and theoretical background thereof. The development of such principles is being analysed in Lithuania and abroad. The word selection while compiling a mini-dictionary of German language dedicated to the students of Civil engineering is being detailed. Furthermore, the article provides recommendations. The word selection has to be based on the linguistic statistics and on the thorough text analysis.

  14. Feasibility of a multiple-choice mini mental state examination for chronically critically ill patients.

    Science.gov (United States)

    Miguélez, Marta; Merlani, Paolo; Gigon, Fabienne; Verdon, Mélanie; Annoni, Jean-Marie; Ricou, Bara

    2014-08-01

    Following treatment in an ICU, up to 70% of chronically critically ill patients present neurocognitive impairment that can have negative effects on their quality of life, daily activities, and return to work. The Mini Mental State Examination is a simple, widely used tool for neurocognitive assessment. Although of interest when evaluating ICU patients, the current version is restricted to patients who are able to speak. This study aimed to evaluate the feasibility of a visual, multiple-choice Mini Mental State Examination for ICU patients who are unable to speak. The multiple-choice Mini Mental State Examination and the standard Mini Mental State Examination were compared across three different speaking populations. The interrater and intrarater reliabilities of the multiple-choice Mini Mental State Examination were tested on both intubated and tracheostomized ICU patients. Mixed 36-bed ICU and neuropsychology department in a university hospital. Twenty-six healthy volunteers, 20 neurological patients, 46 ICU patients able to speak, and 30 intubated or tracheostomized ICU patients. None. Multiple-choice Mini Mental State Examination results correlated satisfactorily with standard Mini Mental State Examination results in all three speaking groups: healthy volunteers: intraclass correlation coefficient = 0.43 (95% CI, -0.18 to 0.62); neurology patients: 0.90 (95% CI, 0.82-0.95); and ICU patients able to speak: 0.86 (95% CI, 0.70-0.92). The interrater and intrarater reliabilities were good (0.95 [0.87-0.98] and 0.94 [0.31-0.99], respectively). In all populations, a Bland-Altman analysis showed systematically higher scores using the multiple-choice Mini Mental State Examination. Administration of the multiple-choice Mini Mental State Examination to ICU patients was straightforward and produced exploitable results comparable to those of the standard Mini Mental State Examination. It should be of interest for the assessment and monitoring of the neurocognitive

  15. Summer Mini Atomiade June 2016

    CERN Multimedia

    Staff Association

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June. ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute. Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has now taken on the challenge of organising a Mini Atomiade from Friday June 3rd to Monday June 6th 2016 in Divonne-les-Bains. The games are made up of four different tournaments/competitions: Small Fi...

  16. Flexible Ureterorenoscopy versus Mini-Percutaneous Nephrolithotomy for the Treatment of Renal Stones.

    Science.gov (United States)

    Ergin, Giray; Kirac, Mustafa; Kopru, Burak; Ebiloglu, Turgay; Biri, Hasan

    2018-04-22

    To compare the pain status and stone free rates of flexible ureterorenoscopy (F-URS) versus mini-percutaneousnephrolithotomy (mini-PNL) for the treatment of 1-to 2-cm renal stones. This study was retrospectively designed with match paired method. Between January 2013 and December 2016, 387 patients underwent stone surgery for renal stones, 45 patients underwent FURS and 45 patients underwent mini-PNL. 90 patients were divided into two groups according to the surgical procedures. Group 1 patients underwent F-URS, and Group 2 patients underwent mini-PNL. During the intraoperative andpostoperative periods, pain management for all patients was standardized. Pain scores were determined using a visual analogue scale (VAS) completed at 2, 6, 12 and 24 hours postoperatively. The stone free status, hemoglobin levels, fluoroscopy time (FT), operation time (OT), hospitalization time (HT), return to work time (RWT), and complications were noted for each patient. Of all patients, the mean age was 41.1 ± 12.1 years and the mean stone size was 13.9 ± 2.9 mm. The VAS scores were significantly higher in the mini-PNL group at 2, 6, 12 and 24 hours (P .05); however, the hemoglobin decreases and the fluoroscopy, operation, hospitalization and return to work times were higher in the mini-PNL group than in the F-URS group (P work duration. We think that F-URS is more comfortable and less painful than mini-PNL and achieves a similar stone free rate for the treatment of 1- to 2-cm renal stones.

  17. Incision and Landsliding Lead to Coupled Increase in Sediment Flux and Grain Size Export

    Science.gov (United States)

    Roda-Boluda, D. C.; Brooke, S.; D'Arcy, M. K.; Whittaker, A. C.; Armitage, J. J.

    2017-12-01

    The rates and grain sizes of sediment fluxes modulate the dynamics and timing of landscape response to tectonics, and dictate the depositional patterns of sediment in basins. Over the last decades, we have gained a good quantitative understanding on how sediment flux and grain size may affect incision and basin stratigraphy. However, we comparably still have limited knowledge on how these variables change with varying tectonic rates. To address this question, we have studied 152 catchments along 8 normal fault-bounded ranges in southern Italy, which are affected by varying fault slip rates and experiencing a transient response to tectonics. Using a data set of 38 new and published 10Be erosion rates, we calibrate a sediment flux predictive equation (BQART), in order to estimate catchment sediment fluxes. We demonstrate that long-term sediment flux is governed by fault slip rates and the tectonically-controlled transient incision, and that sediment flux estimates from the BQART, steady-state assumptions, and incised volumes are highly correlated. This is supported by our 10Be erosion rates, which are controlled by fault slip and incision rates, and the associated landsliding. Based on a new landslide inventory, we show that erosion rate differences are likely due to differences in incision-related landslide activity across these catchments, and that landslides are a major component of sediment fluxes. From a data set of >13000 grain size counts on hillslope grain size supply and fluvial sediment at catchment outlets, we observe that landslides deliver material 20-200% coarser than other sediment sources, and that this coarse supply has an impact on the grain size distributions being exported from the catchments. Combining our sediment flux and grain size data sets, we are able to show that for our catchments, and potentially also for any areas that respond to changes in climate or tectonics via enhanced landsliding, sediment flux and grain size export increase

  18. Drainage development and incision rates in an Upper Pleistocene Basalt-Limestone Boundary Channel: The Sa'ar Stream, Golan Heights, Israel

    Science.gov (United States)

    Shtober-Zisu, N.; Inbar, M.; Mor, D.; Jicha, B. R.; Singer, B. S.

    2018-02-01

    Long-term fluvial incision processes and corresponding geomorphic evolution are difficult to quantify, especially in complex systems affected by lithological and tectonic factors. Volcanic landscapes offer the most appropriate environment for the study of landscape evolution, as there is a clear starting time of formation and the lithology is homogenous. In the present study we aim to: (1) analyse the interplay of construction and incision processes throughout eruptive activity; (2) study fluvial erosion processes; (3) analyse sedimentary and volcanic lithological responses to channel erosion; and (4) calculate the incision rates in young basaltic bedrock. We have integrated existing and new 40Ar/39Ar ages of lava flows with estimates of channel geometry and tectonic activity, and considered process geomorphology concepts, to fully understand evolution of a bedrock channel incised at the boundary between basalts and sedimentary rocks with coeval active volcanic processes forcing drainage evolution. Our findings indicate that the Sa'ar basin evolution is controlled by: (1) rock strength of the mixed lithology; (2) alternating cycles of volcanic activity followed by erosion and incision; and (3) the Plio-Pleistocene uplift of Mt. Hermon. The carbonate slopes composing the southern flank of Mt. Hermon are moderate (18-26%) while the basalt slopes deriving from the Golan Heights are much steeper (26-51%). The highly erodible sedimentary rocks at Mt. Hermon's piedmont accelerated river incision, shaping a 650 m wide by 100 m deep canyon. Inside the canyon, the steep channel slope (8.6%) enables downstream movement of large boulders, including autochthonous mega-blocks (D90 size > 2.5 m); 24 knickpoints were identified using DS plots, developed within a knick zone over a distance of 6 km. The brittle and porous structure of the rubbly and blocky interflow layers (clinkers), interbedded between two massive basalt flows, enhances erosion and accelerates scouring of the

  19. Efficacy of a Buffered 4% Lidocaine Formulation for Incision and Drainage: A Prospective, Randomized, Double-blind Study.

    Science.gov (United States)

    Harreld, Taryn Kratz; Fowler, Sara; Drum, Melissa; Reader, Al; Nusstein, John; Beck, Mike

    2015-10-01

    Incision and drainage of symptomatic emergency patients with facial swelling is painful even after local anesthetics are administered. The purpose of this prospective, randomized, double-blind study was to compare the pain of infiltration and the pain of an incision and drainage procedure of a buffered versus a nonbuffered 4% lidocaine formulation in symptomatic emergency patients presenting with a diagnosis of pulpal necrosis, associated periapical area, and an acute clinical swelling. Eighty-eight emergency patients were randomly divided into 2 groups to receive 2 intraoral infiltration injections (mesial and distal to the swelling) of either 4% lidocaine with 1:100,000 epinephrine buffered with 0.18 mL 8.4% sodium bicarbonate using the Onpharma (Los Gatos, CA) buffering system or 4% lidocaine with 1:100,000 epinephrine. Subjects rated the pain of needle insertion, needle placement, and solution deposition for each injection using a 170-mm visual analog scale. An incision and drainage procedure was performed, and subjects rated the pain of incision, drainage, and dissection on a 170-mm visual analog scale. No significant differences between the buffered and nonbuffered 4% lidocaine formulations were found for needle insertion, placement, and solution deposition of the infiltration injections or for the treatment phases of incision, drainage, and dissection. Buffering a 4% lidocaine formulation did not significantly decrease the pain of infiltrations or significantly decrease the pain of the incision and drainage procedure when compared with a nonbuffered 4% lidocaine formulation in symptomatic patients with a diagnosis of pulpal necrosis and associated acute swelling. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Methodology for fabrication of hydraulics mini turbines with composite materials; Metodologia para a fabricacao de mini turbinas hidraulicas com materiais compostos

    Energy Technology Data Exchange (ETDEWEB)

    Faria, M.T.C. [Universidade Federal de Minas Gerais (DEMEC/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica], Email: mtcdf@uol.com.br; Martinez, C.B.; Viana, E.M.F. [Universidade Federal de Minas Gerais (EHR-UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Hidraulica e Recursos Hidricos], Emails: martinez@cce.ufmg.br, ednamariafaria@bol.com.br

    2009-07-01

    This paper presents the description of methodological procedure specially developed for manufacturing mini turbines. This procedure is used in the design of a Francis type mini turbine with 12.5 kW. The housing volute and the suction tube of this equipment are manufactured with using composed material based on glass fiber and its distributor system is manufactured with stainless steel and brass. At the end it is presented an estimate cost of design / manufacturing of such equipment and a comparison with other equipment in the market.

  1. Methods for roof-top mini-arrays

    Science.gov (United States)

    Hazen, W. E.; Hazen, E. S.

    1985-08-01

    To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

  2. Styles of coping with cancer: the Italian version of the Mini-Mental Adjustment to Cancer (Mini-MAC) scale.

    Science.gov (United States)

    Grassi, Luigi; Buda, Patrizia; Cavana, Laura; Annunziata, Maria Antonietta; Torta, Riccardo; Varetto, Antonella

    2005-02-01

    Mental adjustment to cancer has been explored in a large body of the literature by using the Mental Adjustment to Cancer (MAC) scale. Problems in the factor structure of the scale and the need for refining the instrument have determined the development of the Mini-MAC. The aim of this study was to validate, according to a test-oriented approach, the Italian version of the Mini-MAC. Four hundred and thirty cancer patients in five centres in Northern Italy completed the Mini-MAC and the Brief Symptom Inventory (BSI). A subgroup of 153 patients filled out the instruments again within 3 months of the first assessment. The five original subscales (Fighting Spirit, Hopeless, Fatalism, Anxious Preoccupation and Cognitive Avoidance) showed acceptable levels of reliability (Cronbach alpha coefficients ranging from 0.55 to 0.80) although alphas were lower for the scales Fighting Spirit and Fatalism. Factor analysis (Varimax rotation) identified the same five factors with minor variations from the original version. Again, alpha coefficients were less robust for the factors Fighting Sprit and Fatalism. Hopeless and Anxious Preoccupation were significantly related to all the BSI psychological stress symptoms, including the Global Stress Index (GSI). Test-retest reliability showed no differences in the sub-scales scores between assessments. Copyright (c) 2004 John Wiley & Sons, Ltd.

  3. Protective factor screening for prevention practice: Sensitivity and specificity of the DESSA-Mini.

    Science.gov (United States)

    Shapiro, Valerie B; Kim, B K Elizabeth; Robitaille, Jennifer L; LeBuffe, Paul A

    2017-12-01

    The Devereux Student Strengths Assessment Mini (DESSA-Mini; Naglieri, LeBuffe, & Shapiro, 2011/2014) was designed to overcome practical obstacles to universal prevention screening. This article seeks to determine whether an entirely strength-based, 8-item screening instrument achieves technical accuracy in routine practice. Data come from a district-wide implementation of a new social emotional learning (SEL) initiative designed to promote students' social-emotional competence. All students, kindergarten through Grade 8, were screened using the DESSA-Mini. A random 5 students per classroom received additional assessment. Concurrent and predictive criterion studies were conducted using the full DESSA as well as administrative records of serious disciplinary infraction. The DESSA-Mini showed excellent internal reliability, exceeding .90. Negligible to small differences were found between scores on the DESSA-Mini screen and the DESSA full assessment. Classification consistency between the DESSA-Mini and the DESSA was high (87%-94%) in routine practice, with sensitivity and specificity estimates exceeding Glascoe's (2005) standards. Finally, predictive validity of the DESSA-Mini was reliable; students screened as having a Need for SEL Instruction at the beginning of the year were 4.5 times more likely to have a record of serious disciplinary infraction at the end of the school year compared with those who were not identified (p mental, emotional, and behavioral problems. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  4. Mini-conference on Angular Momentum Transport in Laboratory and Nature

    International Nuclear Information System (INIS)

    Ji, Hantao; Kronberg, Philipp; Prager, Stewart C.; Uzdensky, Dmitri A.

    2008-01-01

    This paper provides a concise summary of the current status of the research and future perspectives discussed in the Mini-Conference on Angular Momentum Transport in Laboratory and Nature. This Mini-conference, sponsored by the Topical Group on Plasma Astrophysics, was held as part of the American Physical Society's Division of Plasma Physics 2007 Annual Meeting (November 12-16, 2007). This Mini-conference covers a wide range of phenomena happening in fluids and plasmas, either in laboratory or in nature. The purpose of this paper is not to comprehensively review these phenomena, but to provide a starting point for interested readers to refer to related research in areas other than their own

  5. Resveratrol engages AMPK to attenuate ERK and mTOR signaling in sensory neurons and inhibits incision-induced acute and chronic pain

    Directory of Open Access Journals (Sweden)

    Tillu Dipti V

    2012-01-01

    Full Text Available Abstract Background Despite advances in our understanding of basic mechanisms driving post-surgical pain, treating incision-induced pain remains a major clinical challenge. Moreover, surgery has been implicated as a major cause of chronic pain conditions. Hence, more efficacious treatments are needed to inhibit incision-induced pain and prevent the transition to chronic pain following surgery. We reasoned that activators of AMP-activated protein kinase (AMPK may represent a novel treatment avenue for the local treatment of incision-induced pain because AMPK activators inhibit ERK and mTOR signaling, two important pathways involved in the sensitization of peripheral nociceptors. Results To test this hypothesis we used a potent and efficacious activator of AMPK, resveratrol. Our results demonstrate that resveratrol profoundly inhibits ERK and mTOR signaling in sensory neurons in a time- and concentration-dependent fashion and that these effects are mediated by AMPK activation and independent of sirtuin activity. Interleukin-6 (IL-6 is thought to play an important role in incision-induced pain and resveratrol potently inhibited IL-6-mediated signaling to ERK in sensory neurons and blocked IL-6-mediated allodynia in vivo through a local mechanism of action. Using a model of incision-induced allodynia in mice, we further demonstrate that local injection of resveratrol around the surgical wound strongly attenuates incision-induced allodynia. Intraplantar IL-6 injection and plantar incision induces persistent nociceptive sensitization to PGE2 injection into the affected paw after the resolution of allodynia to the initial stimulus. We further show that resveratrol treatment at the time of IL-6 injection or plantar incision completely blocks the development of persistent nociceptive sensitization consistent with the blockade of a transition to a chronic pain state by resveratrol treatment. Conclusions These results highlight the importance of signaling

  6. Incisal tooth wear and self-reported TMD pain in children and adolescents.

    Science.gov (United States)

    Hirsch, Christian; John, Mike T; Lobbezoo, Frank; Setz, Juergen M; Schaller, Hans-Guenter

    2004-01-01

    Incisal tooth wear may be a sign of long-term bruxing behavior. Bruxism is purported to be a risk factor for temporomandibular disorders (TMD). The aim of this population-based cross-sectional study was to determine if anterior tooth wear is associated with the self-report of TMD pain in children and adolescents. In a population sample of 1,011 children and adolescents (mean age 13.1 years, range 10 to 18 years; female 52%; response rate 85%), TMD cases were defined as subjects reporting pain in the face, jaw muscles, and temporomandibular joint during the last month according to RDC/TMD. All other subjects were considered controls. Incisal tooth wear was assessed in the clinical examination using a 0 to 2 scale (no wear, enamel wear, dentin wear) for every anterior permanent tooth. The mean wear score for the individuals was categorized into 0, 0.01 to 0.20, 0.21 to 0.40, and 0.41+. A multiple logistic regression analysis, controlling for the effects of age and gender, analyzed the association between the categorized summary wear score and TMD. Specifically, the hypothesis of a trend between higher tooth wear scores and higher risk of TMD was tested. An odds ratio of 1.1 indicated, after adjusting for gender and age, no statistically significantly higher risk of TMD pain with higher tooth wear scores. Incisal tooth wear was not associated with self-reported TMD pain in 10- to 18-year-old subjects.

  7. Rational Design of Mini-Cas9 for Transcriptional Activation.

    Science.gov (United States)

    Ma, Dacheng; Peng, Shuguang; Huang, Weiren; Cai, Zhiming; Xie, Zhen

    2018-04-20

    Nuclease dead Cas9 (dCas9) has been widely used for modulating gene expression by fusing with different activation or repression domains. However, delivery of the CRISPR/Cas system fused with various effector domains in a single adeno-associated virus (AAV) remains challenging due to the payload limit. Here, we engineered a set of downsized variants of Cas9 including Staphylococcus aureus Cas9 (SaCas9) that retained DNA binding activity by deleting conserved functional domains. We demonstrated that fusing FokI nuclease domain to the N-terminal of the minimal SaCas9 (mini-SaCas9) or to the middle of the split mini-SaCas9 can trigger efficient DNA cleavage. In addition, we constructed a set of compact transactivation domains based on the tripartite VPR activation domain and self-assembled arrays of split SpyTag:SpyCatch peptides, which are suitable for fusing to the mini-SaCas9. Lastly, we produced a single AAV containing the mini-SaCas9 fused with a downsized transactivation domain along with an optimized gRNA expression cassette, which showed efficient transactivation activity. Our results highlighted a practical approach to generate down-sized CRISPR/Cas9 and gene activation systems for in vivo applications.

  8. Targeted CNS delivery using human MiniPromoters and demonstrated compatibility with adeno-associated viral vectors

    Directory of Open Access Journals (Sweden)

    Charles N de Leeuw

    2014-01-01

    Full Text Available Critical for human gene therapy is the availability of small promoters tools to drive gene expression in a highly specific and reproducible manner. We tackled this challenge by developing human DNA MiniPromoters (MiniPs using computational biology and phylogenetic conservation. MiniPs were tested in mouse as single-copy knock-ins at the Hprt locus on the X chromosome and evaluated for lacZ reporter expression in central nervous system (CNS and non–CNS tissue. Eighteen novel MiniPs driving expression in mouse brain were identified, 2 MiniPs for driving pan-neuronal expression and 17 MiniPs for the mouse eye. Key areas of therapeutic interest were represented in this set: the cerebral cortex, embryonic hypothalamus, spinal cord, bipolar and ganglion cells of the retina, and skeletal muscle. We also demonstrated that three retinal ganglion cell MiniPs exhibit similar cell type specificity when delivered via adeno-associated virus vectors intravitreally. We conclude that our methodology and characterization has resulted in desirable expression characteristics that are intrinsic to the MiniPromoter, not dictated by copy-number effects or genomic location, and results in constructs predisposed to success in adeno-associated virus. These MiniPs are immediately applicable for preclinical studies toward gene therapy in humans and are publicly available to facilitate basic and clinical research, and human gene therapy.

  9. Mini- or Less-open Sublay Operation (MILOS): A New Minimally Invasive Technique for the Extraperitoneal Mesh Repair of Incisional Hernias.

    Science.gov (United States)

    Reinpold, Wolfgang; Schröder, Michael; Berger, Cigdem; Nehls, Jennifer; Schröder, Alexander; Hukauf, Martin; Köckerling, Ferdinand; Bittner, Reinhard

    2018-01-16

    Improvement of ventral hernia repair. Despite the use of mesh and other recent improvements, the currently popular techniques of ventral hernia repair have specific disadvantages and risks. We developed the endoscopically assisted mini- or less-open sublay (MILOS) concept. The operation is performed transhernially via a small incision with light-holding laparoscopic instruments either under direct, or endoscopic visualization. An endoscopic light tube was developed to facilitate this approach (EndotorchTM Wolf Company). Each MILOS operation can be converted to standard total extraperitoneal gas endoscopy once an extraperitoneal space of at least 8 cm has been created. All MILOS operations were prospectively documented in the German Hernia registry with 1 year questionnaire follow-up. Propensity score matching of incisional hernia operations comparing the results of the MILOS operation with the laparoscopic intraperitoneal onlay mesh operation (IPOM) and open sublay repair from other German Hernia registry institutions was performed. Six hundred fifteen MILOS incisional hernia operations were included. Compared with laparoscopic IPOM incisional hernia operation, the MILOS repair is associated with significantly a fewer postoperative surgical complications (P advantages of open sublay and the laparoscopic IPOM repair.ClinicalTrials.gov Identifier NCT03133000.

  10. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Directory of Open Access Journals (Sweden)

    LuisJoaquín Garcia-Lopez

    Full Text Available Social Anxiety Disorder (SAD is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain.The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1 and clinical sample (study 2.Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls. Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency.Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  11. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T A

    2015-01-01

    Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.

  12. Performance and internal flow condition of mini centrifugal pump with splitter blades

    International Nuclear Information System (INIS)

    Shigemitsu, T; Fukutomi, J; Kaji, K; Wada, T

    2012-01-01

    Mini centrifugal pumps having a diameter smaller than 100mm are employed in many fields. But the design method for the mini centrifugal pump is not established because the internal flow condition for these small-sized fluid machines is not clarified and conventional theory is not suitable for small-sized pumps. Therefore, mini centrifugal pumps with simple structure were investigated by this research. Splitter blades were adopted in this research to improve the performance and the internal flow condition of mini centrifugal pump which had large blade outlet angle. The original impeller without the splitter blades and the impeller with the splitter blades were prepared for an experiment. The performance tests are conducted with these rotors in order to investigate the effect of the splitter blades on performance and internal flow condition of mini centrifugal pump. On the other hand, a three dimensional steady numerical flow analysis is conducted with the commercial code (ANSYS-CFX) to investigate the internal flow condition in detail. It is clarified from the experimental results that the performance of the mini centrifugal pump is improved by the effect of the splitter blades. The blade-to-blade low velocity regions are suppressed in the case with the splitter blades and the total pressure loss regions are decreased. The effects of the splitter blades on the performance and the internal flow condition are discussed in this paper.

  13. Effect of recycling protocol on mechanical strength of used mini-implants.

    Science.gov (United States)

    Estelita, Sérgio; Janson, Guilherme; Chiqueto, Kelly; Ferreira, Eduardo Silveira

    2014-01-01

    Purpose. This study evaluated the influence of recycling process on the torsional strength of mini-implants. Materials and Methods. Two hundred mini-implants were divided into 4 groups with 50 screws equally distributed in five diameters (1.3 to 1.7 mm): control group (CG): unused mini-implants, G1: mini-implants inserted in pig iliac bone and removed, G2: same protocol of group 1 followed by sonication for cleaning and autoclave sterilization, and G3: same insertion protocol of group 1 followed by sonication for cleaning before and after sandblasting (Al2O3-90 µ) and autoclave sterilization. G2 and G3 mini-implants were weighed after recycling process to evaluate weight loss (W). All the screws were broken to determine the fracture torque (FT). The influence of recycling process on FT and W was evaluated by ANOVA, Mann-Whitney, and multiple linear regression analysis. Results. FT was not influenced by recycling protocols even when sandblasting was added. Sandblasting caused weight loss due to abrasive mechanical stripping of screw surface. Screw diameter was the only variable that affected FT. Conclusions. Torsional strengths of screws that underwent the recycling protocols were not changed. Thus, screw diameter choice can be a more critical step to avoid screw fracture than recycling decision.

  14. Magnet-Sleeve-Sealed Mini Trochoidal-Gear Pump Prototype with Polymer Composite Gear

    Directory of Open Access Journals (Sweden)

    Pedro Javier Gamez-Montero

    2017-09-01

    Full Text Available The trochoidal-gear technology has been growing in groundbreaking fields. Forthcoming applications are demanding to this technology a step forward in the conceiving stage of positive displacement machines. The compendium of the qualities and the inherent characteristics of trochoidal-gear technology, especially towards the gerotor pump, together with scale/size factor and magnetic-driven transmission has led to the idea of a magnet-sleeve-sealed variable flow mini trochoidal-gear pump. From its original concept, to the last phase of the design development, the proof of concept, this new product will intend to overcome problems such as noise, vibration, maintenance, materials, and dimensions. The paper aims to show the technological path followed from the concept, design, and model, to the manufacture of the first prototype, where the theoretical and numerical approaches are not always directly reflected in the prototype performance results. Early in the design process, from a standard-commercial sintered metal mini trochoidal-gear unit, fundamental characteristics and dimensional limitations have been evaluated becoming the strategic parameters that led to its configuration. The main technical challenge to confront is being sealed with non-exterior driveshaft, ensuring that the whole interior is filled and wetted with working fluid and helping the hydrodynamic film formation, the pumping effect, and the heat dissipation. Subsequently, the mini pump architecture, embodiment, methodology, materials, and manufacture are presented. The trend of applications of polymer composite materials and their benefits wanted to be examined with this new mini pump prototype, and a pure polyoxymethylene mini trochoidal-gear set has been designed and manufactured. Finally, both the sintered and the polymer trochoidal-gear units have been experimentally tested in an in-house full-instrumented mini test bench. Although the main goal of the presented work is the

  15. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  16. Gully incision rates on the bedrock of a large dip-slope landslide revealed by multi-period LiDAR DEMs

    Science.gov (United States)

    Chan, Y. C.; Hsieh, Y. C.

    2017-12-01

    Recent advances in airborne laser scanning (ALS) technology have provided a great opportunity for characterizing surface erosion through developing improved methods in multi-period DEM differencing and geomorphometry. This study uses three periods of ALS digital elevation model (DEM) data to analyze the short-term erosional features of the Tsaoling landslide triggered by the 1999 Chi-Chi earthquake in Taiwan. Two methods for calculating the bedrock incision rate, the equal-interval cross section selection method and the continuous swath profiles selection method, were used in the study after nearly ten years of gully incision following the earthquake-triggered dip-slope landslide. Multi-temporal gully incision rates were obtained using the continuous swath profiles selection method, which is considered a practical and convenient approach in terrain change studies. After error estimation and comparison of the multi-period ALS DEMs, the terrain change in different periods can be directly calculated, reducing time-consuming fieldwork such as installation of erosion pins and measurement of topographic cross sections on site. In this study, the gully bedrock incision rates ranged between 0.23 and 3.98 m/year, remarkably higher than the typical results from the previous studies. By comparing the DEM data, aerial photos, and precipitation records of this area, the effects of erosion could be observed from the retreat of the Chunqiu Cliff outline during August 2011 to September 2012. It was inferred that the change in the topographic elevation during 2011-2012 was mainly due to the torrential rain brought by Typhoon Soula, which occurred on 30 July 2012. The local gully incision rate in the lower part of the landslide surface was remarkably faster than that of the other regions, suggesting that the fast incision of the toe area possibly contributes to the occurrence of repeated landslides in the Tsaoling area.

  17. Validation of an electronic version of the Mini Asthma Quality of Life Questionnaire.

    Science.gov (United States)

    Olajos-Clow, J; Minard, J; Szpiro, K; Juniper, E F; Turcotte, S; Jiang, X; Jenkins, B; Lougheed, M D

    2010-05-01

    The Mini Asthma Quality of Life Questionnaire (MiniAQLQ) is a validated disease-specific quality of life (QOL) paper (p) questionnaire. Electronic (e) versions enable inclusion of asthma QOL in electronic medical records and research databases. To validate an e-version of the MiniAQLQ, compare time required for completion of e- and p-versions, and determine which version participants prefer. Adults with stable asthma were randomized to complete either the e- or p-MiniAQLQ, followed by a 2-h rest period before completing the other version. Agreement between versions was measured using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Two participants with incomplete p-MiniAQLQ responses were excluded. Forty participants (85% female; age 47.7 +/- 14.9 years; asthma duration 22.6 +/- 16.1 years; FEV(1) 87.1 +/- 21.6% predicted) with both AQLQ scores limitation, emotional function and environmental stimuli domains were 0.94, 0.89, 0.90, and 0.91 respectively. A small but significant bias (Delta=0.3; P=0.004) was noted in the activity limitation domain. Completion time was significantly longer for the e-version (3.8 +/- 1.9min versus 2.7 +/- 1.1min; Ppreferred the e-MiniAQLQ; 35% had no preference. This e-version of the MiniAQLQ is valid and was preferred by most participants despite taking slightly longer to complete. Generalizabilty may be limited in younger (12-17) and older (>65) adults.

  18. Fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision.

    Science.gov (United States)

    Yabe, T; Muraoka, M; Motomura, H; Ozawa, T

    2001-11-01

    Four cases of fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision are reported. Because of lack of suitable arteries for anastomosis in the amputated finger, in each case a volar radial vein was anastomosed to the proximal digital artery and external drainage was performed through a transverse tip incision. In 3 cases the replanted fingertip survived completely; partial necrosis occurred in 1 case. Because veins are more superficial and larger than arteries, they are more available for anastomosis. The results indicate that this method is a useful alternative in fingertip replantation.

  19. "Mini", "Midi" and the Student.

    Science.gov (United States)

    Edwards, Perry; Broadwell, Bruce

    Mini- and midi-computers have been introduced into the computer science program at Sierra College to afford students more direct contact with computers. The college's administration combined with the Science and Business departments to share the expense and utilization of the program. The National Cash Register Century 100 and the Data General…

  20. Infilling and flooding of the Mekong River incised valley during deglacial sea-level rise

    Science.gov (United States)

    Tjallingii, Rik; Stattegger, Karl; Wetzel, Andreas; Van Phach, Phung

    2010-06-01

    The abrupt transition from fluvial to marine deposition of incised-valley-fill sediments retrieved from the southeast Vietnamese shelf, accurately records the postglacial transgression after 14 ka before present (BP). Valley-filling sediments consist of fluvial mud, whereas sedimentation after the transgression is characterized by shallow-marine carbonate sands. This change in sediment composition is accurately marked in high-resolution X-ray fluorescence (XRF) core scanning records. Rapid aggradation of fluvial sediments at the river mouth nearly completely filled the Mekong incised valley prior to flooding. However, accumulation rates strongly reduced in the valley after the river-mouth system flooded and stepped back. This also affected the sediment supply to deeper parts of the southeast Vietnamese shelf. Comparison of the Mekong valley-filling with the East Asian sea-level history of sub- and inter-tidal sediment records shows that the transgressive surface preserved in the incised-valley-fill records is a robust sea-level indicator. The valley was nearly completely filled with fluvial sediments between 13.0 and 9.5 ka BP when sea-level rose rather constantly with approximately 10 mm/yr, as indicated by the East Asian sea-level record. At shallower parts of the shelf, significant sediment reworking and the establishment of estuarine conditions at the final stage of infilling complicates accurate dating of the transgressive surface. Nevertheless, incised-valley-fill records and land-based drill sites indicate a vast and rapid flooding of the shelf from the location of the modern Vietnamese coastline to the Cambodian lowlands between 9.5 ka and 8.5 ka BP. Fast flooding of this part of the shelf is related with the low shelf gradient and a strong acceleration of the East Asian sea-level rise from 34 to 9 meter below modern sea level (mbsl) corresponding to the sea-level jump of melt water pulse (MWP) 1C.

  1. Mini International Neuropsychiatric Interview (MINI): validação de entrevista breve para diagnóstico de transtornos mentais

    OpenAIRE

    Amorim, Patrícia

    2000-01-01

    Objetivos: O MINI é uma entrevista diagnóstica padronizada breve (15-30 minutos), compatível com os critérios do DSM-III-R/IV e da CID-10, que é destinada à utilização na prática clínica e na pesquisa em atenção primária e em psiquiatria, e pode ser utilizada por clínicos após um treinamento rápido (de 1 a 3 horas). A versão Plus do MINI, mais detalhada, gera diagnósticos positivos dos principais transtornos psicóticos e do humor do DSM-IV. Este artigo apresenta os resultados de quatro estudo...

  2. Mandibular Overdentures Retained by Two Mini-Implants: A Seven-Year Retention and Satisfaction Study.

    Science.gov (United States)

    Catalán, Alfonso; Martínez, Alejandra; Marchesani, Francisco; González, Urcesino

    2016-07-01

    Patients with atrophic edentulous ridges generally have problems with retention, therapeutic satisfaction, and comfort with their complete dentures. An alternative treatment to assist in improving retention and stability involves the use of mini-implants. The aim of this study was to evaluate the retention of mandibular overdentures connected to two mini-implants and overall patient satisfaction with them. Seven patients with atrophic mandibular ridges (Type 4D Misch classification), aged 62 to 74 years old were rehabilitated with complete dentures. In each patient, two mini-implants measuring 15 or 13 mm in length and 1.8 mm in diameter were placed. After 15 days, overdentures were connected to the mini-implants with O-ring attachments. In each patient, retention of the overdentures was measured, and a survey of therapeutic satisfaction before and after connection to the mini-implants was administered. Prosthesis retention was measured with a digital dynamometer at 1 month, 6 months, and 2, 3, 5, and 7 years after mini-implant placement. Patient satisfaction was assessed with a survey. Data were analyzed with Student's t-test (satisfaction survey) and the Friedman test (retention measurements and satisfaction survey). The initial retention values (0.34 to 0.63 N without mini-implants) varied significantly (p ≤ 0.050). These values were less than the subsequent measurements of 3.92 to 9.64 N, taken after placement of the mini-implants and connecting them to the dentures. Satisfaction was good to very good over the 7-year observation period. Mucosa and peri-implant bone showed no pathological changes. In this limited sample size clinical study the results indicated that after connecting mandibular overdentures to two mini-implants, patient satisfaction significantly increased and retention significantly improved during the 7-year observation period. © 2015 by the American College of Prosthodontists.

  3. Single-incision, laparoscopic-assisted jejunal resection and anastomosis following a gunshot wound.

    Science.gov (United States)

    Rubin, Jacob A; Shigemoto, Reynsen; Reese, David J; Case, J Brad

    2015-01-01

    A 2 yr old castrated male Pomeranian was evaluated for a 6 wk history of chronic vomiting, intermittent anorexia, and lethargy. Physical examination revealed a palpable, nonpainful, soft-tissue mass in the midabdominal area. Abdominal radiographs and ultrasound revealed a focal, eccentric thickening of the jejunal wall with associated jejunal mural foreign body and partial mechanical obstruction. Following diagnosis of a partial intestinal obstruction as the cause of chronic vomiting, the patient underwent general anesthesia for a laparoscopic-assisted, midjejunal resection and anastomosis using a single-incision laparoscopic surgery port. The patient was discharged the day after surgery, and clinical signs abated according to information obtained during a telephone interview conducted 2 and 8 wk postoperatively. The dog described in this report is a unique case of partial intestinal obstruction treated by laparoscopic-assisted resection and anastomosis using a single-incision laparoscopic surgery port.

  4. Histological Study of Induced Incisions on Rabbits’ Tongues with Three Diode Lasers with Different Wavelengths in Continuous Mode

    Directory of Open Access Journals (Sweden)

    Salwa Yammine

    2018-01-01

    Full Text Available Objective. Diode lasers have multiple indications in everyday dental practice. They allow carrying out incisions, coagulation of soft tissue, and Low-Level Laser Therapy. The goal of this study is to compare histologically the tissue interaction zones and edges of an induced laser incision on rabbits’ tongues with three different wavelengths of 810, 940, and 980 nm in continuous mode. Methods. Fourteen male rabbits were divided into six groups. Each animal underwent three incisions of 10 mm length on the right ventral face of the tongue, carried out in continuous mode with three diode lasers with different wavelengths of 810, 940, and 980 nm. Rabbits were sacrificed at 0, 1, 2, 6, and 15 hours and 14 days. Five rabbits were sacrificed at 0 hours and 2 hours and one rabbit was sacrificed at 1, 6, and 15 hours and at 14 days. The appearance of neutrophils marked the onset time of the inflammatory reaction. Histological study of the incisions was chosen to evaluate the edges and to measure the depth and width of carbonization and necrotic and inflammatory zones. Healing was evaluated at 14 days. Friedman test was used to assess statistical differences between groups. Results. In the experimental adopted conditions, the carbonization zone was marked by degradation of vacuoles and an elongation of nuclei and was observed on the edges of incisions. Carbonization and necrotic and inflammatory zones were measured for rabbits sacrificed at 0, 1, 2, 6, and 15 hours but the onset of inflammation zone marked by the infiltration of neutrophils did not appear before 6 hours. The neutrophils infiltration was higher at 15 hours than at 6 hours. Complete healing was shown at 14 days. According to the time for the regularity of the edges, the interpretation was qualitative without a statistical test. The statistical analysis of the three different diode lasers in this study showed nonsignificant difference between the different groups for the depth (p=0

  5. Eficacia del proceso de esterilización de los Mini-Endo-bloc

    Directory of Open Access Journals (Sweden)

    Maritza Eraso Rodríguez

    2017-01-01

    Full Text Available El Mini-Endo-Bloc® es un elemento usado para mediar las limas durante la endodoncia, presenta muchas concavidades y orificios que dificultan el proceso de esterilización y pueden promover la infección cruzada o comprometer el pronóstico del tratamiento endodóntico. Objetivo: Observar la eficacia de la esterilización de los Mini-Endo-Bloc® utilizados en la clínica de la Federación Odontológica Colombiana (FOC. Métodos: Se recolectaron 60 Mini-Endo-Bloc® utilizados en pacientes que presentaban diagnósticos de necrosis pulpar y periodontitis apical, lo cuales se dividieron en dos grupos: Grupo control: 12 Mini-Endo-Bloc® desinfectados y no esterilizados. Grupo experimental: 48 Mini-Endo-Bloc® desinfectados y esterilizados, se realizó, según lo recomendado por la Farmacopea USPXXXV, prueba de esterilidad en Caldo Thioglycollate a 37°C, medio de caldo Casoy a 37°C y medio de caldo Casoy a 25°C para determinar presencia de bacterias, levaduras y hongos. Resultados: Al someter los Mini-Endo-Bloc® al protocolo de esterilización establecido por la FOC y teniendo en cuenta los parámetros de las pruebas de esterilidad, en el grupo experimental el 50% (n=24, fueron reprobadas (crecimiento microorganismos y 50% (n = 24 fueron aprobadas (no crecimiento de microorganismos. Discusión: la mitad de las muestras fueron reprobadas, estos resultados pueden ser por fallas en el proceso de desinfección mecánica manual directa, el cual se dificulta en los Mini-Endo-Bloc®, debido a su estructura y diseño, permitiendo que residuos biológicos permanezcan en la superficie del instrumento, evitando que el vapor saturado entre en contacto con el material o los microorganismos durante la esterilización.

  6. How does feedback in mini-CEX affect students' learning response?

    Science.gov (United States)

    Sudarso, Sulistiawati; Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-12-19

    This study was aimed to explore students' learning response toward feedback during mini-CEX encounter. This study used a phenomenological approach to identify the students' experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Feedback content and the way of providing feedback on mini-CEX stimulated students' internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students' reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students' increased self-efficacy, attitude, knowledge and clinical skill. Feedback content and the way of providing feedback on mini-CEX stimulates the students' internal processes to do a follow-up on feedback. However, another external factor also affects the students' decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students' learning response.

  7. Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents

    Science.gov (United States)

    Garcia-Lopez, LuisJoaquín; Moore, Harry T. A.

    2015-01-01

    Objectives Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. Methods The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Results Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Conclusions Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided. PMID:26317695

  8. Mini-implants: alternative for oral rehabilitation of a child with ectodermal dysplasia.

    Science.gov (United States)

    Mello, Bianca Zeponi Fernandes; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Valarelli, Fabrício Pinelli; Oliveira, Thais Marchini

    2015-01-01

    Ectodermal dysplasia is a rare congenital disease that affects several structures of ectodermal origin. The most commonly related oral characteristics are hypodontia, malformed teeth and underdeveloped alveolar ridges. New alternative treatments are needed due to the failure of the conventional prosthesis retention. This case report outlines the oral rehabilitation treatment of a 9-year-old girl with ectodermal dysplasia. The treatment was performed with conventional prosthesis upon mini-implants. The mini-implants provided prosthetic retention. The patient reported a good adaptation of the dental prosthesis and satisfaction with the treatment. The increased self-esteem improved the socialization skills of the girl. In this case report, use of prosthesis with mini-implants was satisfactory for prosthetic retention. However, clinical studies with long-term follow-up are needed to test the mini-implants as an alternative for oral rehabilitation of children with ectodermal dysplasia.

  9. MiniGRAIL progress report 2004

    International Nuclear Information System (INIS)

    Waard, A de; Benzaim, Y; Frossati, G; Gottardi, L; Mark, H van der; Flokstra, J; Podt, M; Bassan, M; Minenkov, Y; Moleti, A; Rocchi, A; Fafone, V; Pallottino, G V

    2005-01-01

    The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 μφ 0 Hz -1/2 . The detector was calibrated and the sensitivity curve of MiniGRAIL was determined

  10. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    2002-06-01

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  11. The Lagrangian structure of ozone mini-holes and potential vorticity anomalies in the Northern Hemisphere

    Directory of Open Access Journals (Sweden)

    P. M. James

    Full Text Available An ozone mini-hole is a synoptic-scale area of strongly reduced column total ozone, which undergoes a growth-decay cycle in association with baroclinic weather systems. The tracks of mini-hole events recorded during the TOMS observation period over the Northern Hemisphere provide a database for building anomaly fields of various meteorological parameters, following each mini-hole center in a Lagrangian sense. The resulting fields provide, for the first time, a complete mean Lagrangian picture of the three-dimensional structure of typical ozone mini-holes in the Northern Hemisphere. Mini-holes are shown to be associated with anomalous warm anticyclonic flow in the upper troposphere and cold cyclonic anomalies in the middle stratosphere. Ascending air columns occur upstream and descent downstream of the mini-hole centers. Band-pass filtering is used to reveal the transient synoptic nature of mini-holes embedded within larger scale circulation anomalies. Significant correlations between ozone and Ertel’s potential vorticity on isentropes (IPV both near the tropopause and in the middle stratosphere are shown and then utilized by reconstructing the Lagrangian analysis to follow local IPV anomalies instead of ozone minima. By using IPV as a proxy for ozone, the geopotential anomaly dipolar structure in the vertical characteristic of mini-holes is shown to result from a superposition of two largely independent dynamical components, stratospheric and tropospheric, typically operating on different time scales. Hence, ozone mini-holes may be viewed primarily as phenomena of coincidence.

    Key words. Meteorology and atmospheric dynamics (middle atmosphere dynamics; synoptic-scale meteorology

  12. Investigation of Heat Transfer in Mini Channels using Planar Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Bøgild, Morten Ryge; Poulsen, Jonas Lundsted; Rath, Emil Zacho

    2012-01-01

    In this paper an experimental investigation of the heat transfer in mini channels with a hydraulic diameter of 889 m is conducted. The method used is planar laser induceduorescence (PLIF), which uses the principle of laser excitation of rhodamine B in water. The goal of this study is to validate...... the applicability of PLIF to determine the convective heat transfer coecient in mini channels against conventional correlations of the convective heat transfer coecient. The applicability of the conventional theory in micro and mini channels has been discussed by several researchers, but to the authors knowledge...

  13. Outcomes of small incision lenticule extraction (SMILE) in low myopia.

    Science.gov (United States)

    Reinstein, Dan Z; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine

    2014-12-01

    To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis of 120 consecutive small incision lenticule extraction procedures was performed for low myopia. Inclusion criteria were preoperative spherical equivalent refraction up to -3.50 diopters (D), cylinder up to 1.50 D, and corrected distance visual acuity of 20/20 or better. Outcomes analysis was performed for all eyes with 1-year follow-up according to the Standard Graphs for Reporting Refractive Surgery, and also including mesopic contrast sensitivity. One-year data were available for 110 eyes (92%). Preoperatively, mean spherical equivalent refraction was -2.61 ± 0.54 D (range: -1.03 to -3.50 D) and mean cylinder was 0.55 ± 0.38 D (range: 0.00 to 1.50 D). Postoperatively, mean spherical equivalent refraction was -0.05 ± 0.36 D (range: -0.94 to +1.25 D) and mean cylinder was ± 0.50 D in 84% and ± 1.00 D in 99% of eyes. Uncorrected distance visual acuity was 20/20 or better in 96% of eyes and 20/25 or better in 100% of eyes. One line of corrected distance visual acuity was lost in 9%, but no eyes lost two or more lines. There was an initial overcorrection in mean spherical equivalent refraction on day 1 (+0.37 D) as expected, which regressed to +0.10 D at 1 month and -0.05 D at 3 months, after which stability was reached (mean spherical equivalent refraction was -0.05 D at 1 year). Contrast sensitivity at 1 year was slightly increased at 3, 6, 12, and 18 cycles per degree (P < .05). Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes similar to those previously reported for LASIK. Copyright 2014, SLACK Incorporated.

  14. Mini-tablets versus pellets as promising multiparticulate modified release delivery systems for highly soluble drugs.

    Science.gov (United States)

    Gaber, Dina M; Nafee, Noha; Abdallah, Osama Y

    2015-07-05

    Whether mini-tablets (tablets, diameters ≤6mm) belong to single- or multiple-unit dosage forms is still questionable. Accordingly, Pharmacopoeial evaluation procedures for mini-tablets are lacking. In this study, the aforementioned points were discussed. Moreover, their potential for oral controlled delivery was assessed. The antidepressant venlafaxine hydrochloride (Vx), a highly soluble drug undergoing first pass effect, low bioavailability and short half-life was selected as a challenging payload. In an attempt to weigh up mini-tablets versus pellets as multiparticulate carriers, Vx-loaded mini-tablets were compared to formulated pellets of the same composition and the innovator Effexor(®)XR pellets. Formulations were prepared using various polymer hydrogels in the core and ethyl cellulose film coating with increasing thickness. Mini-tablets (diameter 2mm) showed extended Vx release (<60%, 8h). Indeed, release profiles comparable to Effexor(®)XR pellets were obtained. Remarkably higher coating thickness was required for pellets to provide equivalent retardation. Ethyl cellulose in the core ensured faster release due to polymer migration to the surface and pore formation in the coat. mini-tablets showed higher stability to pellets upon storage. Industrially speaking, mini-tablets proved to be superior to pellets in terms of manufacturing, product quality and economical aspects. Results point out the urgent need for standardized evaluation procedures for mini-tablets. Copyright © 2015. Published by Elsevier B.V.

  15. Psychometric Properties of the Persian Adaptation of Mini-Cog Test in Iranian Older Adults.

    Science.gov (United States)

    Rezaei, Mohammad; Rashedi, Vahid; Lotfi, Gohar; Shirinbayan, Peymaneh; Foroughan, Mahshid

    2018-04-01

    The aim of this study was to assess the psychometric properties of the Mini-Cog in Iranian older adults. It was a cross-sectional study; 50 older people with dementia and 50 without dementia who matched for age, gender, and education entered the study. The diagnostic and statistical manual of mental disorders criteria for dementia were used as gold standard. A battery of scales included the abbreviated mental test score (AMTS), the Geriatric Depression Scale, and the Mini-Cog was performed. Validity and reliability of the Mini-Cog determined using the Pearson product-moment correlation coefficient (Pearson's r), Cronbach's alpha, and Receiver Operating Characteristic (ROC) curve analysis. The Persian version of Mini-Cog showed a good inter-rater reliability ( K = 0.76, p Mini-Cog have an acceptable sensitivity, specificity, and substantial overall agreement with the AMTS.

  16. The MiniBIOS model (version 1A4) at the RIVM

    NARCIS (Netherlands)

    Uijt de Haag PAM; Laheij GMH

    1993-01-01

    This report is the user's guide of the MiniBIOS model, version 1A4. The model is operational at the Laboratory of Radiation Research of the RIVM. MiniBIOS is a simulation model for calculating the transport of radionuclides in the biosphere and the consequential radiation dose to humans. The

  17. Role of mini-scleral lens in mucous membrane pemphigoid

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2017-01-01

    Full Text Available This study aims to report the use of mini-scleral contact lens in the management of mucous membrane pemphigoid (MMP with persistent epithelial defects. A 68-year-old male with a history of ocular pain and declining visual acuity was referred to our clinic with a diagnosis of MMP. His corrected distance visual acuity (CDVA was 20/200 in the right eye and 20/100 in the left eye. Despite being on lubricants, topical steroids and intravenous cyclophosphamide, the patient developed persistent corneal epithelial defects in both eyes. He was then given a trial of mini-scleral lenses. Within 4 weeks, corneal epithelial defects healed, and at 6 months, the CDVA had improved to 20/50 in the right eye and 20/40 in the left eye. By improving the corneal surface integrity and visual function, mini-scleral lenses can play a role in the visual rehabilitation of patients with MMP.

  18. Modified Lengthening Temporalis Myoplasty Involving an Extended Lazy-S Incision to Avoid Facial Scar Formation.

    Science.gov (United States)

    Oji, Tomito; Hayashi, Akiteru; Ogino, Akihiro; Onishi, Kiyoshi

    2018-05-01

    Lengthening temporalis myoplasty is a faster and less invasive alternative to free muscle transfer for smile reconstruction. However, it requires a nasolabial fold incision, which leaves a midfacial scar. Based on esthetic considerations, a modified approach, involving an extended lazy-S (parotidectomy) incision instead of a nasolabial fold incision, was developed. A cadaveric study involving 10 hemifaces was conducted. From February 2013 to March 2016, the modified lengthening temporalis myoplasty procedure was employed in 10 patients. The results were graded from 1 (poor) to 5 (excellent) according to the Terzis grading system. The excursion of the oral commissure was also measured. The extended lazy-S incision provides easy and safe access to the coronoid process and good visibility. The patients' mean age was 56.5 years, and the mean duration of the postoperative follow-up period was 22.2 months. The patients' underlying conditions included acoustic neuroma (n = 2), Bell palsy (n = 3), congenital conditions (n = 2), brain infarction (n = 1), Ramsay Hunt syndrome (n = 1), and malignant parotid lymphoma (n = 1). One patient suffered a surgical site infection, which was successfully treated with irrigation. All the patients achieved improvements in smile symmetry: 2, 5, and 3 patients obtained excellent, good, and moderate results, respectively. The excursion of the oral commissure ranged from 5 to 10 mm. The modified lengthening temporalis myoplasty procedure provides satisfactory functional outcomes without causing significant complications. It does not leave a facial scar and is a preferable option, especially for young and female patients, and patients who have undergone ablative surgery involving the parotid region.

  19. Transversal incision of the vagina favors the remaining of the tape in the middle-third urethra compared to longitudinal incision during transobturator sling procedures for stress urinary incontinence.

    Science.gov (United States)

    Pirtea, L; Sas, I; Ilina, Razvan; Grigoraș, D; Mazilu, O

    2015-07-17

    To describe a new type of incision of the vagina during transobturator sling procedure and to evaluate by ultrasound the tape position at 3, 6 and 12 months after surgery. We conducted a prospective study including 51 patients with urinary stress incontinence who underwent sling procedure using the transversal vaginal incision. Tape position was evaluated by ultrasound at 3, 6 and 12 months after surgery and expressed as a percentage of the urethral length (the proximal third of the urethral length 0-39 %, the middle third 40-60 %, and the distal third 60-100 %). Informed consent was obtained from all patients prior to their inclusion in the study. All procedures have been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments and were approved by the Institutional Review Board and Ethical Committee of "Victor Babeş" University of Medicine and Pharmacy Timisoara before the beginning of the study (no 7/17.04.2012). At 3 months after surgery, 3.92 % of the slings were located in the proximal third of the urethra, 88.23 % in the middle third of the urethra and 7.84 % in the distal third. At 6 and 12 months after surgery we obtained similar results: 9.81 % of the slings were located in the proximal third of the urethra, 82.35 % in the middle third and 7.84 % in the distal third of the urethra. The transversal incision of the vagina offers a minimal dissection along the long axis of the urethra favoring the remaining of the tape in the middle third of the urethra.

  20. Fluvial incision by the Qingyijiang River on the northern fringe of Mt. Huangshan, eastern China: Responses to weakening of the East Asian summer monsoon

    Science.gov (United States)

    Hu, Chunsheng; Liu, Shaochen; Hu, Chenqi; Xu, Guanglai; Zhou, Yingqiu

    2017-12-01

    This paper focuses on climatic and tectonic controls to determine their relative importance to the Quaternary fluvial incision by the Qingyijiang River, eastern China. The Qingyijiang, which is one of longest tributaries of the lower Yangtze River, drains the northern piedmont of Mt. Huangshan. A field survey focused on three natural sections of the Qingyijiang in the Jingxian basin, where a well-preserved sequence of one alluvial platform (P) and three fluvial terraces (T3, T2, and T1) is presented. The heights of the platform and the terraces above river level are 65, 40, 20, and 7 m respectively. In this study, electron spin resonance (ESR), optical stimulated luminescence (OSL), and palaeomagnetic dating were applied to reconstruct the fluvial incision history of the Qingyijiang and evaluate the possible influence of tectonic uplift and/or climate change on the fluvial incision. The main results show that (1) the ages of P, T3, T2, and T1 were determined to be ∼ 1300, ∼ 900, ∼ 600, and ∼ 1.5 ka respectively, corresponding to four incision events in the Qingyijiang; (2) the East Asian summer monsoon (EASM) experienced four significant weakening events at 1300, 900, 600, and ∼ 1.5 ka, according to previous research. Correspondingly, we propose that four significant increased periods of regional precipitation occurred at 1300, 900, 600, and ∼ 1.5 ka in the study area because of the negative correlation between the intensity of the EASM and regional precipitation from 1960 to 2012; and (3) fluvial incision by the Qingyijiang arose as a result of the weakening of the EASM in combination with tectonic uplift, determined by matching fluvial incision history of the Qingyijiang with tectonic movement and EASM change. In addition, the weakening of the EASM climatically triggered fluvial incision by the Qingyijiang. This study supports the conclusion that major fluvial incision has been climatically triggered; however, it also suggests that the mechanism of

  1. Caracterização de mini-implantes utilizados na ancoragem ortodôntica Characterization of the mini-implants used to orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Luciana Rougemont Squeff

    2008-10-01

    Full Text Available INTRODUÇÃO: o diâmetro reduzido do mini-implante, e a decorrente facilidade na sua inserção, minimizam a possibilidade de erro do operador e de contato entre a rosca do mini-implante e a raiz dentária. Entretanto, o risco de fratura da peça aumenta à medida que seu diâmetro é diminuído. MÉTODOS: neste trabalho foram analisados quatro produtos de marcas nacionais (INP, SIN, Conexão e Neodente e um de marca alemã (Mondeal, com o objetivo de identificar características importantes para o bom desempenho deste recurso como acessório de ancoragem. Foram observados composição e design das peças e realizado o ensaio mecânico de torque até a fratura (estudo in vitro, cujos valores foram submetidos à análise de variância (ANOVA e teste de Tukey. RESULTADOS: os resultados mostraram que todos os mini-implantes testados estão aptos à utilização clínica como reforço de ancoragem ortodôntica.INTRODUCTION: The reduced diameter of the mini-implants and the simplicity of the technique could minimize the operator mistake's possibility and avoid the contact between the thread of the screw and the dental root. In spite of that, it increases the fracture risk because of the diameter's decrease. METHODS: At the present work, mini-implants from five different trade marks, four Brazilian systems (INP, SIN, Conexão and Neodente and a German system (Mondeal were studied to identify important characteristics of this anchorage accessory, like composition, design and resistance to the insertion torque (in vitro. The values obtained from the mechanical torque test were submitted to variance analysis (ANOVA and Tukey's test. RESULTS: All studied groups presented good results and are recommended to orthodontic clinic use.

  2. Post irradiation examination of HANARO nucler mini-element fuel (metallographic and density test)

    International Nuclear Information System (INIS)

    Yoo, Byung Ok; Hong, K. P.; Park, D. G.; Choo, Y. S.; Baik, S. J.; Kim, K. H.; Kim, H. C.; Jung, Y. H.

    2001-05-01

    The post irradiation examination of a HANARO mini-element nuclear fuel, KH96C-004, was done in June 6, 2000. The purpose of this project is to evaluate the in-core performance and reliability of mini-element nuclear fuel for HANARO developed by the project T he Nuclear Fuel Material Development of Research Reactor . And, in order to examine the performance of mini-element nuclear fuel in normal output condition, the post irradiation examination of a nuclear fuel bundle composed by 6 mini nuclear fuel rods and 12 dummy fuel rods was performed. Based on these examination results, the safety and reliability of HANARO fuel and the basic data on the design of HANARO nuclear fuel can be ensured and obtained,

  3. Primary fixation of mini slings: a comparative biomechanical study in vivo

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2012-04-01

    Full Text Available INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control, as follows: TVT-Secur® (Gynecare, USA, Type 1 polypropylene mesh (control; Ophira Mini Sling System® (Promedon, Argentina, Tissue Fixation System® (TFS PTY, Australia, Zipper Sling® and "T device" (Prosurg, USA. The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments. The force was measured in Newtons (N. RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.

  4. Validity of a short clinical interview for psychiatric diagnosis : the mini-SCAN

    NARCIS (Netherlands)

    Nienhuis, F. J.; van de Willige, G.; Rijnders, C. A. Th.; de Jonge, P.; Wiersma, D.

    Background To promote clinical application of the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) system a shorter version (the mini-SCAN) was devised. Its psychometric properties were unknown. Aims To establish the validity and practical properties of the mini-SCAN. Method One hundred

  5. Application on small incision extracapsular cataract extraction in large-scale vision recovery action in Shaanxi Province

    Directory of Open Access Journals (Sweden)

    Juan Zhang

    2014-09-01

    Full Text Available AIM: To investigate the characteristics of scale cataract operations and the effects and experiences of small incision extracapsular cataract extraction with intraocular lens(IOLimplantation in large-scale vision recovery action. METHODS: Four thousand eight hundred ninety-two cases(4 892 eyesof cataract were treated by small incision non-phacoemulcification cataract extraction from March 2010 to November 2011 in our hospital(Fuming No.1 surgery car of Shaanxi Provincewhich were retrospectively analyzed. Visual acuity, intraoperative and postoperative complications, the recovery of postoperative inflammation were observed. RESULTS: Visual acuity reached 0.3 or more in 4 521 eyes(92.42%at 1d after the operation, at 3d after the operation in 4 571 eyes(93.44%, there were 4 887 eyes with IOL implantation, implantation rate was 99.90%. All the cases had lesser intraoperative and postoperative complications, and the postoperative inflammation recovered quickly. CONCLUSION: Small incision extracapsular cataract extraction with IOL implantation is simple, effective, economical, safe and adapting for large-scale vision recovery action.

  6. Replacing the AMOR with the miniDOAS in the ammonia monitoring network in the Netherlands

    NARCIS (Netherlands)

    Berkhout, Augustinus J. C.; Swart, Daan P. J.; Volten, Hester; Gast, Lou F. L.; Haaima, Marty; Verboom, Hans; Stefess, Guus; Hafkenscheid, Theo; Hoogerbrugge, Ronald

    2017-01-01

    In this paper we present the continued development of the miniDOAS, an active differential optical absorption spectroscopy (DOAS) instrument used to measure ammonia concentrations in ambient air. The miniDOAS has been adapted for use in the Dutch National Air Quality Monitoring Network. The miniDOAS

  7. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  8. Preparation and Evaluation of Hot-Melt Extruded Patient-Centric Ketoprofen Mini-Tablets.

    Science.gov (United States)

    Alshetaili, Abdullah S; Almutairy, Bjad K; Tiwari, Roshan V; Morott, Joseph T; Alshehri, Sultan M; Feng, Xin; Alsulays, Bader B; Park, Jun-Bom; Zhang, Feng; Repka, Michael A

    2016-01-01

    Bitter tasting drugs represent a large portion of active pharmaceutical ingredients. Mini-tablets are specifically designed for patients with difficulty in swallowing particular in young children up to 10 years of age, geriatric patients and patients with esophagitis. The present study was aimed to prepare, taste-masked mini-tablets, which are easily swallowed dosage forms, primarily to be used by pediatric and geriatric patients. Ketoprofen (10%-50% w/w) and Eudragit® EPO were blended and extruded with a 5-mm strand die and cut into consistent mini-tablets by using an adapted downstream pelletizer. Differential scanning calorimetry and polarized light microscopy-hot stage microscopy studies confirmed that the binary mixtures were miscible under the employed extrusion temperatures. In-vitro release studies showed that drug release was less than 0.5% within the first 2 min in simulated salivary fluid (pH 6.8) and more than 90% in the first 20 min in gastric media (pH 1.0). The results of the electronic tongue analysis were well correlated with the drug release profile of the mini-tablets in the artificial saliva. Scanning electron microscopy revealed no cracks on the surface of the minitablets, confirming that the mini-tablets were compact solids. Chemical imaging confirmed the uniform distribution of ketoprofen inside the polymer matrices. Eudragit® EPO containing ketoprofen at various drug loads were successfully melt extruded into tastedmasked mini-tablets. The reduced drug release at salivary pH correlated well with Astree e-Tongue studies for taste masking efficiency.

  9. Rapid channel incision of the lower Pearl River (China since the 1990s as a consequence of sediment depletion

    Directory of Open Access Journals (Sweden)

    X. X. Lu

    2007-12-01

    Full Text Available This paper reported a dramatic channel incision (>10 m in the deepest cut during the past 10 y or so in the lower Pearl River, the second largest river in terms of water discharge in China. The channel incision had caused changes both in the channel geometry as well as in the river hydraulics. Also, the water exchange between the two major tributaries of the Pearl River, the Xijiang and Beijiang, had been significantly changed due to the channel incision. The rapid channel incision was principally the result of extensive sand mining in the lower Pearl River and the delta region due to the booming economy in the Pearl Delta region. Slight increase of water discharge and significant decrease of sediment load since the early 1990s in both the Xijiang and Beijiang also likely contributed to the observed dramatic river bed downcutting to some extent. This has important implications for river management, as the large Chinese rivers have seen a dramatic depletion of sediment fluxes due to the combined effects of declining rainfall, dam constructions, water diversion, reforestation and afforestation, and sediment mining over the recent decades.

  10. Identification of processed Chinese medicinal materials using DNA mini-barcoding.

    Science.gov (United States)

    Song, Ming; Dong, Gang-Qiang; Zhang, Ya-Qin; Liu, Xia; Sun, Wei

    2017-07-01

    Most of Chinese medicinal herbs are subjected to traditional processing procedures, including stir-frying, charring, steaming, boiling, and calcining before they are released into dispensaries. The marketing and identification of processed medicinal materials is a growing issue in the marketplace. However, conventional methods of identification have limitations, while DNA mini-barcoding, based on the sequencing of a short-standardized region, has received considerable attention as a new potential means to identify processed medicinal materials. In the present study, six DNA barcode loci including ITS2, psbA-trnH, rbcL, matK, trnL (UAA) intron and its P6 loop, were employed for the authentication of 45 processed samples belonging to 15 species. We evaluated the amplification efficiency of each locus. We also examined the identification accuracy of the potential mini-barcode locus, of trnL (UAA) intron P6 loop. Our results showed that the five primary barcode loci were successfully amplified in only 8.89%-20% of the processed samples, while the amplification rates of the trnL (UAA) intron P6 loop were higher, at 75.56% successful amplification. We compared the mini-barcode sequences with Genbank using the Blast program. The analysis showed that 45.23% samples could be identified to genus level, while only one sample could be identified to the species level. We conclude that trnL (UAA) p6 loop is a candidate mini-barcode that has shown its potential and may become a universal mini-barcode as complementary barcode for authenticity testing and will play an important role in medicinal materials control. Copyright © 2017 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  11. How does feedback in mini-CEX affect students’ learning response?

    Science.gov (United States)

    Rahayu, Gandes Retno; Suhoyo, Yoyo

    2016-01-01

    Objective This study was aimed to explore students’ learning response toward feedback during mini-CEX encounter. Methods This study used a phenomenological approach to identify the students’ experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Results Feedback content and the way of providing feedback on mini-CEX stimulated students’ internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students’ reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students’ increased self-efficacy, attitude, knowledge and clinical skill. Conclusions Feedback content and the way of providing feedback on mini-CEX stimulates the students’ internal processes to do a follow-up on feedback. However, another external factor also affects the students’ decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students’ learning response. PMID:28008136

  12. The SIMS trial: adjustable anchored single-incision mini-slings versus standard tension-free midurethral slings in the surgical management of female stress urinary incontinence. A study protocol for a pragmatic, multicentre, non-inferiority randomised controlled trial.

    Science.gov (United States)

    Abdel-Fattah, Mohamed; MacLennan, Graeme; Kilonzo, Mary; Assassa, R Phil; McCormick, Kirsty; Davidson, Tracey; McDonald, Alison; N'Dow, James; Wardle, Judith; Norrie, John

    2017-08-11

    Single-incision mini-slings (SIMS) represent the third generation of midurethral slings. They have been developed with the aim of offering a true ambulatory procedure for treatment of female stress urinary incontinence (SUI) with reduced morbidity and earlier recovery while maintaining similar efficacy to standard midurethral slings (SMUS). The aim of this study is to determine the clinical and cost-effectiveness of adjustable anchored SIMS compared with tension-free SMUS in the surgical management of female SUI, with 3-year follow-up. A pragmatic, multicentre, non-inferiority randomised controlled trial. The primary outcome measure is the patient-reported success rate measured by the Patient Global Impression of Improvement at 12 months. The primary economic outcome will be incremental cost per quality-adjusted life year gained at 12 months. The secondary outcomes measures include adverse events, objective success rates, impact on other lower urinary tract symptoms, health-related quality of life profile and sexual function, and reoperation rates for SUI. Secondary economic outcomes include National Health Service and patient primary and secondary care resource use and costs, incremental cost-effectiveness and incremental net benefit. The statistical analysis of the primary outcome will be by intention-to-treat and also a per-protocol analysis. Results will be displayed as estimates and 95% CIs. CIs around observed differences will then be compared with the prespecified non-inferiority margin. Secondary outcomes will be analysed similarly. The North of Scotland Research Ethics Committee has approved this study (13/NS/0143). The dissemination plans include HTA monograph, presentation at international scientific meetings and publications in high-impact, open-access journals. The results will be included in the updates of the National Institute for Health and Care Excellence and the European Association of Urology guidelines; these two specific guidelines directly

  13. Single-incision video-assisted anatomical segmentectomy with handsewn bronchial closure for endobronchial lipoma.

    Science.gov (United States)

    Galvez, Carlos; Sesma, Julio; Bolufer, Sergio; Lirio, Francisco; Navarro-Martinez, Jose; Galiana, Maria; Baschwitz, Benno; Rivera, Maria Jesus

    2016-08-01

    Endobronchial lipomas are rare benign tumors whose symptoms are usually confused with recurrent infections or even asthma diagnosis, and mostly caused by endobronquial obstructive component which also conditions severity. We report a case of a 60-year-old man with a right-lower lobe upper-segment endobronchial myxoid tumor with uncertain diagnosis. We performed a single incision video-assisted anatomical segmentectomy and wedge bronchoplasty with handsewn closure to achieve complete resection and definitive diagnosis. During the postoperative air leak was not observed and there was no complication, with low pain scores and complete recovery. Final pathological exam showed endobronchial lipoma. Single-incision (SI) anatomical segmentectomies are lung-sparing resections for benign or low-grade malignancies with diagnostic and therapeutic value, and the need for a wedge bronchoplasty is not a necessary indication for conversion to multiport or open thoracotomy.

  14. Grau de aceitação de mini-implantes por pacientes em tratamento ortodôntico: estudo preliminar The mini-implants acceptance rate by patients in orthodontic treatments: a preliminary study

    Directory of Open Access Journals (Sweden)

    Larissa Bustamante Capucho Brandão

    2008-10-01

    Full Text Available OBJETIVOS: os mini-implantes atualmente representam um grande avanço na Ortodontia, por proporcionarem máxima ancoragem com o mínimo de cooperação dos pacientes. No entanto, ainda existem algumas dúvidas quanto ao uso destes dispositivos temporários de ancoragem no que se refere, principalmente, aos aspectos psicológicos de aceitação pelos pacientes durante o tratamento ortodôntico. METODOLOGIA: dez pacientes adultos, portadores de má oclusão de Classe I, com biprotrusão, que foram submetidos a tratamento ortodôntico com a colocação de quatro mini-implantes nos arcos dentários, entre os primeiros molares e segundos pré-molares superiores e inferiores, responderam a um questionário, com o objetivo de avaliar as condições de aceitação dos mini-implantes. RESULTADOS: as respostas indicaram que a maioria dos pacientes aceitou prontamente o procedimento, estavam satisfeitos e recomendariam para outros pacientes (90%, enquanto 50% tiveram alguma preocupação com os procedimentos cirúrgicos e os outros 50% não relataram nenhum desconforto. O tempo médio de tolerância a partir da colocação foi de 3 dias e a maioria tolerou os implantes durante todo o tratamento ortodôntico. CONCLUSÕES: pôde-se concluir que os mini-implantes foram aceitos de forma positiva pela maioria dos pacientes submetidos ao tratamento ortodôntico.OBJECTIVE: Actually, mini-implants as anchorage resources have been spotlight in Orthodontics, providing maximum anchorage with minimum patient's cooperation. However, there are still some restrictions regarding the use of these temporary anchorage devices, and among these, the psychological aspects and the patient's acceptance, which still not properly evaluated. METHODS: Ten adults patients, with Class I biprotrusion malocclusion, that were submitted to orthodontic treatment with the implantation of four mini-implants, in the dental arches, among upper and lower first molar and second premolar teeth, in

  15. The Norwegian version of the Mini-Mental Adjustment to Cancer Scale: factor structure and psychometric properties.

    Science.gov (United States)

    Bredal, Inger Schou

    2010-02-01

    The object of the study was to examine the factor structure and the psychometric properties of the Mini-Mental Adjustment to Cancer Scale (Mini-MAC) among a large sample of Norwegian breast cancer patients. A total of 402 patients with breast cancer completed the Mini-MAC. Principal component analysis with varimax rotion confirmed four factors. Three had psychometric properties to the original Mini-MAC Helpless-Hopeless (HH), Anxious Preoccupation (AP) and Cognitive Avoidance (CA) subscales. The fourth, named Positive Attitude (PA) combined the Fighting Spirit (FS) and the Fatalism subscales of the original Mini-MAC. Construct validities were assessed by examining the interscale correlations as well as the correlations between the Mini-MAC subscales and the HADS subscales scores. Internal consistency of the five subscales was satisfactory for the original (HH, AP, CA, FA, coefficients=0.60-0.83), except for the FS subscale (coefficient=21). In view of the low internal reliability for the Norwegian Mini-MAC FS subscale coefficient; it appears to be more appropriate to use the Norwegian Mini-MAC as a four-factor model. If researcher or clinicians in Norway use the five-factor model, they should take great care when interpreting the fighting spirit subscale.

  16. From Rindler horizon to mini black holes at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Ghaffary, Tooraj [Islamic Azad University, Department of Science, Shiraz Branch, Shiraz (Iran, Islamic Republic of)

    2017-02-15

    Recently researchers (A. Sepehri et al., Astrophys. Space Sci. 344, 79 (2013)) have considered the signature of superstring balls near mini black holes at LHC and calculate the information loss for these types of strings. Motivated by their work, we consider the evolution of events in high energy experiments from lower energies for which the Rindler horizon is formed to higher energies in which mini black holes and string balls are emerged. Extending the Gottesman and Preskill method to string theory, we find the information loss for excited strings ''string balls'' in mini black holes at LHC and calculate the information transformation from the collapsing matter to the state of outgoing Hawking radiation for strings. We come to the conclusion that information transformation for high energy strings is complete. Then the thermal distribution of excited strings near mini black holes at LHC is calculated. In order to obtain the total string cross section near black holes produced in proton-proton collision, we multiply the black hole production cross section by the thermal distribution of strings. It is observed that many high energy excited strings are produced near the event horizon of TeV black holes. These excited strings evaporate to standard model particles like Higgs boson and top quark at Hagedorn temperature. We derive the production cross section for these particles due to string ball decay at LHC and consider their decay to light particles like bottom quarks and gluons. (orig.)

  17. Model Pemberdayaan Laboratorium Bank Mini Syariah di Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Eva Fauziah

    2018-03-01

    results showed that the model of empowerment of Mini Sharia Bank laboratory in Higher Education has four models; they are 1 model of secondary empowerment, 2 model primary internal empowerment of student, 3 model of primary internal empowerment of student and lecturer and 4 model of primary external empowerment. This laboratory empowerment model is based on observations at four universities in Java, namely Bandung Islamic University (UNISBA, Islamic University of Malang (UNISMA, UIN Malang and UIN Sunan Ampel Surabaya. Laboratorium Bank Mini Syariah merupakan sarana penunjang dan pelaksana program Tri Dharma Perguruan Tinggi yang diharapkan mampu memberikan kontribusi untuk mengakselerasi perkembangan syariah di Indonesia. Oleh karena itu, pemberdayaan laboratorium Bank Mini Syariah sebagai tempat mengembangkan kompetensi baik dalam bidang intelektual, ketrampilan motorik dan terampil memggunakan alat-alat media perbankan syariah untuk peningkatan kompetensi mahasiswa lulusan keuangan dan perbankan syariah perlu ditelaah. Metode penelitian menggunakan metode kualitatif dengan teknik pengumpulan data observasi mendalam. Analisis data menggunakan analisis domain model spradley. Hasil penelitian menunjukkan bahwa model pemberdayaan laboratorium Bank Mini Syariah di Perguruan Tinggi memiliki empat model yaitu 1. Model pemberdayaan sekunder, 2. Model pemberdayaan primer internal mahasiswa, 3. Model pemberdayaan primer internal mahasiswa dan dosen, dan 4. Model pemberdayaan primer eksternal. Model pemberdayaan laboratorium ini berdasarkan pengamatan pada empat perguruan tinggi di Jawa yaitu Universitas Islam Bandung, Universitas Islam Malang, UIN Malang dan UIN Sunan Ampel Surabaya.

  18. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    International Nuclear Information System (INIS)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda

    2016-01-01

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  19. Poster - 23: Dosimetric Characterization and Transferability of an Accessory Mounted Mini-Beam Collimator

    Energy Technology Data Exchange (ETDEWEB)

    Davis, William; Crewson, Cody; Alexander, Andrew; Cranmer-Sargison, Gavin; Kundapur, Vijayananda [University of Saskatchewan Department of Physics and engineering Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics, Saskatchewan Cancer Agency Department of Medical Physics (Canada)

    2016-08-15

    Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimator inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.

  20. Neutronics analysis on mini test fuel in the RSG-GAS core

    International Nuclear Information System (INIS)

    Tukiran S; Tagor M Sembiring

    2016-01-01

    Research on UMo fuel for research reactor has been developed. The fuel of research reactor is uranium molybdenum low enrichment with high density. For supporting the development of fuel fabrication, an neutronic analysis of mini fuel plates in the RSG-GAS core was performed. The aim of analysis is to determine the numbers of fuel cycles in the core to know the maximum fuel burn-up. The mini fuel plates of U_7Mo-Al and U_6Zr-Al with densities of 7.0 gU/cc and 5.2 gU/cc, respectively, will be irradiated in the RSG-GAS core. The size of both fuels, namely 630 x 70.75 x 1.30 mm were inserted to the 3 plates of dummy fuel. Before the fuel will be irradiated in the core, a calculation for safety analysis from neutronics and thermal-hydraulics aspects were required. However, in this paper, it will be discussed safety analysis of the U_7Mo-Al and U_6Zr-Al mini fuels from neutronic point of view. The calculation was done using WIMSD-5B and Batan-3DIFF codes. The result showed that both of the mini fuels could be irradiated in the RSG-GAS core with burn up less than 70 % within 12 cycles of operation without over limiting the safety margin. If it is compared, the power density of U_7Mo-Al mini fuel is bigger than U_6Zr-Al fuel. (author)

  1. Local analgesic effect of tramadol is mediated by opioid receptors in late postoperative pain after plantar incision in rats.

    Science.gov (United States)

    de Oliveira Junior, José Oswaldo; de Freitas, Milena Fernandes; Bullara de Andrade, Carolina; Chacur, Marucia; Ashmawi, Hazem Adel

    2016-01-01

    Tramadol is a drug used to treat moderate to severe pain. It is known to present a peripheral effect, but the local mechanisms underlying its actions remain unclear. The role of peripheral opioid receptors in postoperative pain is not well understood. In the present study, we examined the peripheral opioid receptors to determine the local effect of tramadol in a plantar incision pain model. Rats were subjected to plantar incision and divided into four groups on postoperative day (POD) 1: SF_SF, 0.9% NaCl injected into the right hindpaw; SF_TraI, 0.9% NaCl and tramadol injected into the right hindpaw; SF_TraC, 0.9% NaCl and tramadol injected into the contralateral hindpaw; and Nal_Tra, naloxone and tramadol injected into the ipsilateral hindpaw. To determine the animals' nociceptive threshold, mechanical hyperalgesia was measured before incision, on POD1 before treatment and at 15, 30, 45, and 60 minutes after the incision. The same procedure was repeated on the POD2. The expression levels of μ-opioid receptor (MOR) and δ-opioid receptor (DOR) were obtained through immunoblotting assays in the lumbar dorsal root ganglia (L3-L6) in naïve rats and 1, 2, 3, and 7 days after the incision. Our results showed that the plantar incision was able to cause an increase in mechanical hyperalgesia and that tramadol reversed this hyperalgesia on POD1 and POD2. Tramadol injections in the contralateral paw did not affect the animals' nociceptive threshold. Naloxone was able to antagonize the tramadol effect partially on POD1 and completely on POD2. The DOR expression increased on POD2, POD3, and POD7, whereas the MOR expression did not change. Together, our results show that tramadol promoted a local analgesic effect in the postoperative pain model that was antagonized by naloxone in POD2, alongside the increase of DOR expression.

  2. Plantar Fascia Release Through a Single Lateral Incision in the Operative Management of a Cavovarus Foot: A Cadaver Model Analysis of the Operative Technique.

    Science.gov (United States)

    Kiskaddon, Eric M; Meeks, Brett D; Roberts, Joseph G; Laughlin, Richard T

    2018-04-04

    Plantar fascia release and calcaneal slide osteotomy are often components of the surgical management for cavovarus deformities of the foot. In this setting, plantar fascia release has traditionally been performed through an incision over the medial calcaneal tuberosity, and the calcaneal osteotomy through a lateral incision. Two separate incisions can potentially increase the operative time and morbidity. The purpose of the present study was threefold: to describe the operative technique, use cadaveric dissection to analyze whether a full release of the plantar fascia was possible through the lateral incision, and examine the proximity of the medial neurovascular structures to both the plantar fascia release and calcaneal slide osteotomy when performed together. In our cadaveric dissections, we found that full release of the plantar fascia is possible through the lateral incision with no obvious damage to the medial neurovascular structures. We also found that the calcaneal branch of the tibial nerve reliably crossed the osteotomy in all specimens. We have concluded that both the plantar fascia release and the calcaneal osteotomy can be safely performed through a lateral incision, if care is taken when completing the calcaneal osteotomy to ensure that the medial neurovascular structures remain uninjured. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Strong feedbacks between hillslope sediment production and channel incision by saltation-abrasion

    Science.gov (United States)

    Lundbek Egholm, David; Faurschou Knudsen, Mads; Sandiford, Mike

    2013-04-01

    While it is well understood that rivers erode mountain ranges by incising the bedrock and by transporting sediments away from the ranges, the basic physical mechanisms that drive long-term bedrock erosion and control the lifespan of mountain ranges remain uncertain. A particularly challenging paradox is reconciling the dichotomy associated with the high incision rates observed in active mountain belts, and the long-term (108 years) preservation of significant topographic reliefs in inactive orogenic belts (e.g. von Blankenburg, 2005). We have performed three-dimensional computational experiments with a landscape evolution model that couples bedrock landslides and sediment flux-dependent river erosion by saltation-abrasion (Sklar & Dietrich, 2004). The coupled model experiments show strong feedbacks between the channel erosion and the hillslope delivery of sediments. The feedbacks point to hillslope sediment production rate as the main control on channel erosion rates where saltation-abrasion dominates over other fluvial erosion processes. Our models results thus highlight the importance of hillslope sediment production controlled by climate and tectonic activity for scaling erosion rates in fluvial systems. Because of variations in landslide frequency, the feedbacks make tectonic activity a primary driver of fluvial erosion and help clarifying the long-standing paradox associated with the persistence of significant relief in old orogenic belts, up to several hundred-million-years after tectonic activity has effectively ceased. References F. von Blankenburg. The control mechanisms of erosion and weathering at basin scale from cosmogenic nuclides in river sediment. Earth Planet. Sci. Lett. 237, 462-479 (2005). L. S. Sklar, W. E. Dietrich. A mechanistic model for river incision into bedrock by saltating bed load. Water Resour. Res. 40, W06301 (2004).

  4. Response of the Apodi-Mossoró estuary-incised valley system (NE Brazil to sea-level fluctuations

    Directory of Open Access Journals (Sweden)

    Helenice Vital

    2010-01-01

    Full Text Available This study focuses on the Quaternary sea level changes in the Apodi-Mossoró Estuary and adjacent shelf, Northeastern Brazil, based on the analysis of high-resolution seismic profiles, integrated with echosounder, SRTM and satellite image data. We use these data to develop a relative stratigraphy. An incised-valley extending from the Apodi-Mossoró Estuary onto the shelf dominates the investigated area. In very shallow waters (down to 10 m depth the channel lies mainly in a NW-SE direction, changing to NE-SW in waters below10 m, in the form of a J-shaped valley. The southern flank of the shallow channel presents an abrupt morphology, probably determined by a residual scarp due to neotectonic reactivation of a pre-existing fault. This incised-valley can be correlated with a former river valley formed during the late Pleistocene fall in sea-level. The base-level change related to this drop in sea level can be regionally expressed on seismic lines as a laterally-continuous stratigraphic surface named Horizon I, interpreted as representing the sub-aerial exposure of the continental shelf. Many incised valleys were excavated on this exposed shelf, including that of the Apodi-Mossoró Estuary and its incised valley system. This incised valley has lain buried since the Holocene transgression. The Holocene sediments present sub-horizontal layers, or they have filled the incised valley with oblique features.Este estudo utiliza a integração de dados sísmicos de alta resolução, batimétricos, SRTM e imagens de satélite para desenvolvimento da estratigrafia relativa visando entender as variações do nível do mar durante o Quaternário no estuário do rio Apodi-Mossoró e plataforma adjacente, nordeste do Brasil. A principal feição identificada foi um canal submerso, na plataforma interna, parcialmente preenchido, provavelmente relacionado com o sistema de vales incisos formado durante o rebaixamento do nível do mar no Pleistoceno. O canal

  5. Final report of phase 2 'Mini-cogeneration in the flower bulb industry'; Eindrapportage Fase 2 'Mini-WKK in de bloembollensector'

    Energy Technology Data Exchange (ETDEWEB)

    Koolwijk, E. [Cogen Projects, Driebergen-Rijsenburg (Netherlands); Smailbegovic, N. [SenterNovem, Utrecht (Netherlands)

    2009-09-15

    Phase 2 of the project 'mini-cogeneration in the flower bulb industry' is the sequel to the report 'mini-cogeneration in the flower bulb industry. Use of cogeneration in the cultivation and hot bed of tulip and hyacinth', Addressing the incentivisation of the use of cogeneration in the sector and working toward realizing a number of demonstration projects. To this end it is necessary that potential investors are given insight in the feasibility of cogeneration at their business and that their enthusiasm is kindled for the use of cogeneration. This was done by disseminating information in the flower bulb industry about the opportunities of cogeneration and by informing growers about technique, economy and points of interest. [Dutch] Fase 2 van het project 'Mini- WKK in de bloembollensector' is een vervolg op het rapport 'Mini-wkk in de bloembollensector. Toepassing van wkk bij teelt en broei van tulp en hyacint' en richt zich op het stimuleren van de toepassing van WKK in de sector en toewerken naar realisatie van een aantal demonstratieprojecten. Daartoe is het noodzakelijk dat potentiele investeerders inzicht krijgen over de haalbaarheid van WKK op hun bedrijf en geenthousiasmeerd worden voor het gebruik van WKK. Dit is gedaan door informatie in de bollensector te verspreiden over de mogelijkheden van WKK en telers te informeren over techniek, economie en aandachtspunten.

  6. Summer Mini Atomiade in June 2016

    CERN Multimedia

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June.   ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute.  Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has taken on the challenge of organising a Mini Atomiade from Friday 3 June to Monday 6 June 2016 in Divonne-les-Bains. The ga...

  7. Four-stranded mini microtubules formed by Prosthecobacter BtubAB show dynamic instability.

    Science.gov (United States)

    Deng, Xian; Fink, Gero; Bharat, Tanmay A M; He, Shaoda; Kureisaite-Ciziene, Danguole; Löwe, Jan

    2017-07-18

    Microtubules, the dynamic, yet stiff hollow tubes built from αβ-tubulin protein heterodimers, are thought to be present only in eukaryotic cells. Here, we report a 3.6-Å helical reconstruction electron cryomicroscopy structure of four-stranded mini microtubules formed by bacterial tubulin-like Prosthecobacter dejongeii BtubAB proteins. Despite their much smaller diameter, mini microtubules share many key structural features with eukaryotic microtubules, such as an M-loop, alternating subunits, and a seam that breaks overall helical symmetry. Using in vitro total internal reflection fluorescence microscopy, we show that bacterial mini microtubules treadmill and display dynamic instability, another hallmark of eukaryotic microtubules. The third protein in the btub gene cluster, BtubC, previously known as "bacterial kinesin light chain," binds along protofilaments every 8 nm, inhibits BtubAB mini microtubule catastrophe, and increases rescue. Our work reveals that some bacteria contain regulated and dynamic cytomotive microtubule systems that were once thought to be only useful in much larger and sophisticated eukaryotic cells.

  8. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    Energy Technology Data Exchange (ETDEWEB)

    Dicle, O. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Kuecuekler, C. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Pirnar, T. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Erata, Y. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey); Posaci, C. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey)

    1997-02-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs.

  9. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    International Nuclear Information System (INIS)

    Dicle, O.; Kuecuekler, C.; Pirnar, T.; Erata, Y.; Posaci, C.

    1997-01-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs

  10. Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

    Science.gov (United States)

    Calladine, Daniel; Tanner, Vaughan

    2009-08-01

    To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT). Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom. Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surgery. Half the CCIs had stromal hydration with a balanced salt solution and half did not. Incisions were made with a 2.75 mm steel keratome. Intraocular pressure (IOP) was measured within 90 minutes after surgery. The CCI length and corneal thickness at the CCI site were measured using software built into the AS-OCT system. Thirty CCIs were evaluated. Stromal hydration significantly increased the measured CCI length (Pthe result of a trend toward increased corneal thickness at the CCI site with hydration (PThe mean CCI length was 1.69 mm +/- 0.27 (SD) (range 1.31 to 2.32 mm) with hydration and 1.51 +/- 0.23 mm (range 1.30 to 1.95 mm) without hydration. The mean IOP was 20.9 +/- 8.18 mm Hg and 15.8 +/- 8.20 mm Hg, respectively. The IOP tended to be higher with hydration (Pthe eye with a higher early postoperative IOP, showing the importance of taking stromal hydration into account when designing similar OCT studies of CCI architecture.

  11. The transverse colon cancer with the reversed rotation of the midgut treated with single incision laparoscopic colectomy.

    Science.gov (United States)

    Hirano, Yasumitsu; Hattori, Masakazu; Fujita, Manami; Nishida, Youji; Douden, Kenji; Hashizume, Yasuo

    2013-06-01

    Reversed rotation of the midgut is a rare type of intestinal malrotation. Moreover, synchronous colon cancer has rarely been reported. Preliminary experience with single-incision laparoscopic colectomy (SILC) for colon cancer with reversed rotation of the midgut is reported. An 82-year-old woman was admitted because of a fecal occult blood. A colonoscopy revealed transverse colon cancer. An air-barium contrast enema showed the right-sided sigmoid colon and the left-sided cecum. A computed tomography revealed that the duodenum and the transverse colon were situated at the ventral side of the superior mesenteric artery, and a preoperative diagnosis of suspicion of reversed rotation of the midgut was made. First, a lap protector was inserted through a 4.0 cm transumbilical incision. Four 5 mm ports were placed in the lap protector. On the observation of laparoscopy, the cecum and the ascending colon were not fixed with the retroperitoneum and situated on the left, and the sigmoid colon was situated on the right. We successfully mobilized the transverse colon using a single-incision laparoscopic approach. Resection was achieved following extracorporealization, and the anastomosis was performed extracorporeally using staplers. The patient was discharged on the thirteenth postoperative day. Postoperative follow-up did not reveal any umbilical wound complications. SILC for colon cancer associated with malrotation of the midgut is feasible and a promising alternative method because of its less invasiveness and its adaptability to the malrotation without extending the skin incision.

  12. Neutrinos from the NuMI beamline in the MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, Alexis A.

    2006-01-01

    With the startup of the NuMI beamline early in 2005, the MiniBooNE detector has the unique opportunity to be the first user of an off-axis neutrino beam (110 mrad off-axis). MiniBooNE is assembling a rich sample of neutrino interactions from this source

  13. USE OF RENEWABLE SUBSTRATES FOR EX VITRO PRODUCTION OF Melaleuca alternifolia CHEEL CLONAL PLANTS BY MINI-CUTTINGS TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Carlos Andre Stuepp

    2017-12-01

    Full Text Available The Australian species Melaleuca alternifolia Cheel. has a strong commercial importance due to the extraction of essential oils from its leaves used in the cosmetic and pharmaceutical industry. In order to obtain an efficient plant production system of M. alternifolia the mini-cuttings technique and the clonal mini-garden management in the productivity and rooting of mini-cuttings and different substrate compositions were analyzed during all the seasons. Mini-stumps derived from cuttings and grown in pots (2 L, were submitted to successive harvesting of their sprouts during the four seasons (september/2013 to august/2014. From the mini-stumps sprouts mini-cuttings were produced, wich were were planted in plastic tubes and kept in a greenhouse for 45 days. Six substrates were used for planting the mini-cuttings: commercial substrate (S1; substrate composed of 100% carbonized rice husk (CRH (S2; substrate composed of 100% coconut fiber (CF (S3; substrate composed of 50% CF and 50% CRH (S4; substrate composed of 30% CF and 70% CRH (S5; substrate composed of 70% FC and 30% CRH (S6. The high survival of mini-stumps (over 90% and the mini-cuttings production (282 mini-cuttings.m-2.month-1 in the shade house demonstrate the technical feasibility for the species, being summer the most appropriate time to collect propagules. The substrate composed by 70% CF + 30% CRH (S6 shows superior results for vegetative propagation of M. alternifolia (91.7% of rooted mini-cuttings, as the single one to contemplate simultaneously all parameters. Summer is recommended as the best time for rooting of mini-cuttings.

  14. Magnet-Retained Two-Mini-Implant Overdenture: Clinical and Mechanical Consideration

    Directory of Open Access Journals (Sweden)

    Yuichi Ishida

    2016-10-01

    Full Text Available Two-implant overdentures have become the accepted treatment for restoring mandibular edentulism. The dimensions of regular implants sometimes limit their use, such as in the case of narrow ridges. Mini-implants with reduced diameters (less than 3.0 mm enable insertion into narrow ridges. A magnet-retained two-mini-implant overdenture system was developed and is described in this paper. Additionally, we describe a clinical mandibular procedure using the system and evaluate its biomechanical performance.

  15. Mini-interfacial Fracture Toughness of a Multimode Adhesive Bonded to Plasma-treated Dentin.

    Science.gov (United States)

    Ayres, Ana Paula Almeida; Pongprueksa, Pong; De Munck, Jan; Gré, Cristina Parise; Nascimento, Fábio Dupart; Giannini, Marcelo; Van Meerbeek, Bart

    2017-01-01

    To investigate the bonding efficacy of a multimode adhesive to plasma-treated and -untreated (control) dentin using a mini-interfacial fracture toughness (mini-iFT) test. Twenty human molars were used in a split-tooth design (n = 10). The adhesive Scotchbond Universal (SBU; 3M ESPE) was applied in etch-and-rinse (E&R) and self-etch (SE) modes. Mid-coronal dentin was exposed and covered with a standardized smear layer ground to 320 grit. One half of each dentin surface received 15 s of non-thermal atmospheric plasma (NTAP), while the other half was covered with a metallic barrier and kept untreated. Following the E&R mode, dentin was plasma treated immediately after phosphoric acid etching. SBU and a resin-based composite were applied to dentin following the manufacturer's instructions. Six mini-iFT specimens were prepared per tooth (1.5 x 2.0 x 16 to 18 mm), and a single notch was prepared at the adhesive-dentin interface using a 150-μm diamond blade under water cooling. Half of the mini-iFT specimens were immediately loaded until failure in a 4-point bending test, while the other half were first stored in distilled water for 6 months. After testing, the exact dimensions of the notch were measured with a measuring optical microscope, from which ΚIc was determined. Three-way ANOVA revealed higher mini-iFT for SBU applied in E&R than SE mode for both storage times, irrespective of NTAP treatment. Overall, mini-iFT did not decrease for any of the experimental groups upon 6-month aging, while plasma treatment did not show a direct beneficial effect on mini-iFT of SBU applied in either E&R or SE mode.

  16. Evaluation of the success and complication rates of self-drilling orthodontic mini-implants.

    Science.gov (United States)

    Gurdan, Z; Szalma, J

    2018-05-01

    Orthodontic mini-implants are important devices for successful anchorage management in orthodontics; however, the survival of these devices depends on several clinical factors. The aim of our study was to calculate the success and complication rates of orthodontic mini-implants. In this retrospective study, patients of our orthodontic department were enrolled, getting overall 59 orthodontic mini-implants during their orthodontic treatment in a 2-year period. Every patient had one or more of the 1.6 mm × 8 mm in size self-drilling mini-implants (Jeil Dual Top Anchor System, Jeil Medical Corp., Seoul, Korea). Screw loading was performed immediately after insertions, keeping tension forces under 150 g. Soft tissue and bone infections, implant mobility and screw loss, implant fracture, and neighboring tooth injury were registered. Relationships between variables were tested using the Chi-square test for statistical significance. The success rate of the orthodontic mini-implants was 89.8% in this study while the average loading period was 8.1 months. Soft-tissue infections varied between 6.3% and 33.3% of the cases while screw mobility varied between 3.1% and 20.8% of the cases regarding the anatomic localization. Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034). Screw mobility was significantly more frequent in the buccal fold than in the palate (P = 0.034) and screw mobility was found more frequently in case of intrusions than by extrusions (P = 0.036). The overall success rate of mini-implants was found acceptable in this study, however, screw mobility in the buccal fold showed a high incidence, suggesting the thorough consideration of the immediate loading by buccal mini-implants.

  17. A cost-effective fluorescence mini-microscope for biomedical applications.

    Science.gov (United States)

    Zhang, Yu Shrike; Ribas, João; Nadhman, Akhtar; Aleman, Julio; Selimović, Šeila; Lesher-Perez, Sasha Cai; Wang, Ting; Manoharan, Vijayan; Shin, Su-Ryon; Damilano, Alessia; Annabi, Nasim; Dokmeci, Mehmet Remzi; Takayama, Shuichi; Khademhosseini, Ali

    2015-01-01

    We have designed and fabricated a miniature microscope from off-the-shelf components and a webcam, with built-in fluorescence capability for biomedical applications. The mini-microscope was able to detect both biochemical parameters, such as cell/tissue viability (e.g. live/dead assay), and biophysical properties of the microenvironment such as oxygen levels in microfabricated tissues based on an oxygen-sensitive fluorescent dye. This mini-microscope has adjustable magnifications from 8-60×, achieves a resolution as high as microscope was able to chronologically monitor cell migration and analyze beating of microfluidic liver and cardiac bioreactors in real time, respectively. The mini-microscope system is cheap, and its modularity allows convenient integration with a wide variety of pre-existing platforms including, but not limited to, cell culture plates, microfluidic devices, and organs-on-a-chip systems. Therefore, we envision its widespread application in cell biology, tissue engineering, biosensing, microfluidics, and organs-on-chips, which can potentially replace conventional bench-top microscopy where long-term in situ and large-scale imaging/analysis is required.

  18. Development of a multiparticulate system containing enteric-release mini-tablets of omeprazole

    Directory of Open Access Journals (Sweden)

    Volnei Jose Tondo Filho

    2014-09-01

    Full Text Available The main aim of this study was to develop a multiparticulate system containing mini-tablets of omeprazole formulated with an enteric polymer with pH-dependent solubility. Pre-formulation studies showed good flow and compaction capacity, leading to the production ofhigh quality mini-tablets. The mini-tablets were coated in a fluidized bed with hydroxypropylmethylcellulose /Eudragit(r L30D55 and packed into hard gelatin capsules. The dissolution profile showed gastro-resistance and zero-order kinetics. The dissolution profile for the formulation containing lactose as the diluent and coated with 12% (tablet weight gain of polymer was similar to that ofthe reference drug.

  19. Mini hydro power in Peninsular Malaysia - the past, present and future

    International Nuclear Information System (INIS)

    Bhaskar Kannan

    2006-01-01

    The early development of mini hydro development in Peninsular Malaysia was carried out by the National Electricity Board (NEB) and the projects developed in the 50s and 60s were Ulu Langat (Selangor), Sempam, Kg. Raja , Kuala Terla, and Robinson Falls (all in Pahang). In the 70s the main effort of hydropower development was concentrated on developing major hydropower projects not only to cater to the country increasing demand for electricity but also to the country needs for flood control. This development was feverishly carried out on the Perak River and the prohects built were Temenggor (384 MW), Bersia (72 MW), Kenering (20 MW), Sg Piah (70 MW) and the Kenyir (400 MW) project in Sungai Terengganu. In late 1970s, the government was keen to electrify the rural areas of Peninsular Malaysia and mini hydro power development was thought of as an option to provide electricity to these areas. The Mini Hydro Department of National Electricity Board (MHD) was then formed to undertake the task of planning, developing and implementing mini hydro projects to meet this government aspiration. Table 1 shows the list of projects identified and implemented and its status

  20. The development and evaluation of mini-GEMs - short, focused, online e-learning videos in geriatric medicine.

    Science.gov (United States)

    Garside, Mark J; Fisher, James M; Blundell, Adrian G; Gordon, Adam L

    2018-01-01

    Mini Geriatric E-Learning Modules (Mini-GEMs) are short, focused, e-learning videos on geriatric medicine topics, hosted on YouTube, which are targeted at junior doctors working with older people. This study aimed to explore how these resources are accessed and used. The authors analyzed the viewing data from 22 videos published over the first 18 months of the Mini-GEM project. We conducted a focus group of U.K. junior doctors considering their experiences with Mini-GEMS. The Mini-GEMs were viewed 10,291 times over 18 months, equating to 38,435 minutes of total viewing time. The average viewing time for each video was 3.85 minutes. Learners valued the brevity and focused nature of the Mini-GEMs and reported that they watched them in a variety of settings to supplement clinical experiences and consolidate learning. Watching the videos led to an increase in self-reported confidence in managing older patients. Mini-GEMs can effectively disseminate clinical teaching material to a wide audience. The videos are valued by junior doctors due to their accessibility and ease of use.