WorldWideScience

Sample records for mini glaucoma shunt

  1. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

    Directory of Open Access Journals (Sweden)

    Tojo N

    2015-03-01

    Full Text Available Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS.Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea 

  2. Aqueous shunts for glaucoma.

    Science.gov (United States)

    Tseng, Victoria L; Coleman, Anne L; Chang, Melinda Y; Caprioli, Joseph

    2017-07-28

    Aqueous shunts are employed to control intraocular pressure (IOP) for people with primary or secondary glaucomas who fail or are not candidates for standard surgery. To assess the effectiveness and safety of aqueous shunts for reducing IOP in glaucoma compared with standard surgery, another type of aqueous shunt, or modification to the aqueous shunt procedure. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 8), MEDLINE Ovid (1946 to August 2016), Embase.com (1947 to August 2016), PubMed (1948 to August 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to August 2016), ClinicalTrials.gov (www.clinicaltrials.gov); searched 15 August 2016, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en); searched 15 August 2016. We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 15 August 2016. We also searched the reference lists of identified trial reports and the Science Citation Index to find additional trials. We included randomized controlled trials that compared various types of aqueous shunts with standard surgery or to each other in eyes with glaucoma. Two review authors independently screened search results for eligibility, assessed the risk of bias, and extracted data from included trials. We contacted trial investigators when data were unclear or not reported. We graded the certainty of the evidence using the GRADE approach. We followed standard methods as recommended by Cochrane. We included 27 trials with a total of 2099 participants with mixed diagnoses and comparisons of interventions. Seventeen studies reported adequate methods of randomization, and seven reported adequate allocation concealment. Data collection and follow-up times varied.Four trials compared an aqueous shunt (Ahmed or Baerveldt) with trabeculectomy, of which

  3. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  4. The Ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study

    NARCIS (Netherlands)

    de Jong, Leo A. M. S.

    2009-01-01

    The purpose of this study was to establish the efficacy and safety of the Ex-PRESS (Optonol Ltd., Neve Ilan, Israel) mini glaucoma shunt in open-angle glaucoma. This was a prospective, randomized trial. Eyes from enrolled patients were randomly assigned to either Ex-PRESS implantation under a

  5. Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

    Science.gov (United States)

    Akil, Handan; Vu, Priscilla Q; Nguyen, Anhtuan H; Nugent, Alexander; Chopra, Vikas; Francis, Brian A; Tan, James C

    2017-12-01

    The purpose of this is to describe a venting stitch modification for valveless glaucoma aqueous shunts and characterize early postoperative intraocular pressure (IOP) and glaucoma medication use following the modification. Retrospective chart review of 61 sequential patients undergoing Baerveldt glaucoma implant (BGI)-350 implantation at the Doheny Eye Institute. Twenty-four patients received a glaucoma shunt with venting stitch modification (modified BGI) and 37 patients received an unmodified shunt (BGI-only). IOP, number of glaucoma medications, and number of hypotony cases (intraocular pressure ≤5 mm Hg) were compared between the groups. T-tests were used for statistical analysis. At postoperative-day 1, mean IOP was significantly lower compared with preoperatively in the modified BGI group (14 mm Hg; reduced by 51%; P<0.0001) but not the BGI-only group (27 mm Hg; P=0.06). IOP difference between groups persisted till immediately before tube opening (P=0.005) and fewer IOP-lowering medications needed in the modified BGI group (P<0.0001). One case (4.2%) of postoperative hypotony was encountered with BGI modification, which resolved after the stitch was removed in clinic. The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

  6. Oculoplastic technique of connecting a glaucoma valve shunt to extraorbital locations in cases of severe glaucoma.

    Science.gov (United States)

    Rubin, Peter A D; Chang, Eli; Bernardino, Carlo Roberto; Hatton, Mark P; Dohlman, Claes H

    2004-09-01

    To describe a technique for inserting glaucoma shunts to the sinuses or the lacrimal sac as a means of lowering intraocular pressure in patients with refractory glaucoma associated with severe ocular surface disease. Nineteen patients with severe ocular surface disease necessitating a keratoprosthesis and with intractable glaucoma underwent placement of a modified Ahmed shunt to direct aqueous in the maxillary or ethmoid sinus or lacrimal sac. Intraocular pressure is presently well controlled without glaucoma medications in two thirds of patients. None of the patients had endophthalmitis. Established oculoplastic surgery techniques may be used to redirect aqueous to extraorbital locations and effectively lower intraocular pressure in patients with severe ocular surface disease and refractory glaucoma. This procedure has not been associated with endophthalmitis.

  7. Retinal complications after aqueous shunt surgical procedures for glaucoma.

    Science.gov (United States)

    Law, S K; Kalenak, J W; Connor, T B; Pulido, J S; Han, D P; Mieler, W F

    1996-12-01

    To assess retinal complications and to identify risk factors for retinal complications following aqueous shunt procedures. Records of 38 consecutive aqueous shunt procedures that were performed on 36 patients at the Eye Institute of the Medical College of Wisconsin, Milwaukee, from June 1993 to March 1995 (minimum follow-up, 6 months) were reviewed. The mean +/- SD follow-up was 11.4 +/- 5.2 months (median, 10.5 months). Twelve patients (32%) had the following retinal complications: 4 serous choroidal effusions (10%) that required drainage, 3 suprachoroidal hemorrhages (8%), 2 vitreous hemorrhages (5%), 1 rhegmatogenous retinal detachment (3%), 1 endophthalmitis (3%), and 1 scleral buckling extrusion (3%). Surgical procedures for retinal complications were required in 8 (67%) of these 12 patients. Visual acuity decreased 2 lines or more in 9 (75%) of these 12 patients. The median onset of a postoperative retinal complication was 12.5 days, with 10 patients (83%) experiencing complications within 35 days. Serous choroidal effusions developed in 10 other patients (26%), and these effusions resolved spontaneously. Visual acuity decreased 2 lines or more in 2 (20%) of these additional 10 patients. Patients who experienced serious retinal complications were significantly older, had a higher rate of hypertension, and postoperative ocular hypotony. Serious retinal complications were distributed evenly among patients with Krupin valves with discs and Molteno and Baerveldt devices. Experience with the Ahmed glaucoma valve implant was limited. Aqueous shunt procedures may be associated with significant retinal complications and subsequent visual loss.

  8. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    Science.gov (United States)

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  9. Electron microscopic evaluation of a gold glaucoma micro shunt after explantation.

    Science.gov (United States)

    Berk, Thomas A; Tam, Diamond Y; Werner, Liliana; Mamalis, Nick; Ahmed, Iqbal Ike K

    2015-03-01

    We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Combined Glaucoma Tube Shunt (Ahmed) and Fluocinolone Acetonide (Retisert™) Implantation Compared to Ahmed Alone in Uveitic Glaucoma.

    Science.gov (United States)

    Zivney, Mark; Lin, Phoebe; Edmunds, Beth; Parikh, Mansi; Takusagawa, Hana; Tehrani, Shandiz

    2016-12-01

    Glaucoma is a known complication of uveitis, and may require glaucoma tube shunt implantation for intraocular pressure (IOP) control. The success of glaucoma tube shunt implantation in the setting of a local ocular steroid depot in uveitic glaucoma remains unknown. The purpose of this study was to determine whether patients who underwent combined glaucoma tube shunt (Ahmed) and fluocinolone acetonide (Retisert™, Bausch + Lomb, Bridgewater, NJ, USA) implantation have superior outcomes compared to patients with Ahmed implants only in the setting of uveitic glaucoma. All participants were studied retrospectively and underwent Ahmed implantation alone or with existing/concurrent Retisert implantation (combined group) at a single academic institution. The main outcome measures were IOP, visual acuity (VA), number of IOP-lowering medications, and adverse events at 6 months after Ahmed implantation. Secondary outcome measures included adverse events and surgical success at 6 months after Ahmed implantation. Mean IOP at 6 months after Ahmed implantation was 15.3 ± 4.8 and 15.1 ± 4.9 mm Hg in the Ahmed only group (n = 17) and the combined group (n = 17), respectively (p = 0.89). The mean number of IOP-lowering medications at 6 months after Ahmed implantation was 1.7 ± 1.0 and 1.8 ± 1.0 in the Ahmed only group and the combined group, respectively (p = 0.86). Mean VA at 6 months after Ahmed implantation was 0.35 ± 0.29 and 0.42 ± 0.33 log mean angle of resolution in the Ahmed only group and the combined group, respectively (p = 0.50). No significant differences in surgical success or adverse events were noted between the two groups. At 6 months, no significant differences in mean IOP, mean number of IOP-lowering medications, VA, surgical success, or adverse events were noted between Ahmed implantation alone or combined Ahmed and Retisert implantation in patients with uveitic glaucoma.

  11. Patch Grafting Using an Ologen Collagen Matrix to Manage Tubal Exposure in Glaucoma Tube Shunt Surgery

    Directory of Open Access Journals (Sweden)

    Masaki Tanito

    2018-01-01

    Full Text Available Purpose: To report the results using an ologen Collagen Matrix as a patch graft in eyes with tubal exposure after tube shunt surgery. Case Reports: Case 1 was an 82-year-old man with tubal exposure in his right eye 26 months after receiving a Baerveldt glaucoma implant. The tube was covered by surrounding conjunctival tissue combined with subconjunctival placement of an ologen Collagen Matrix as a patch graft. Two years after implantation, the tube was not exposed. Anterior-segment optical coherence tomography (AS-OCT showed dense conjunctival tissue over the tube. Case 2 was an 82-year-old man with peripheral keratitis, anterior scleritis, and secondary glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve and cataract surgery. Intraoperatively, scleritis-related scleral thinning prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Seventeen months after implantation, the tube was not exposed. Case 3 was a 52-year-old man with diabetic maculopathy and steroid-induced glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve. Intraoperatively, a flap defect prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Three weeks postoperatively, AS-OCT showed thick subconjunctival tissue over the tube. Three months after implantation, the tube was not exposed. Conclusions: The ologen Collagen Matrix can be used successfully as a patch graft to prevent and treat tubal exposure after tube shunt surgery.

  12. Design, Fabrication, and In Vitro Testing of an Anti-biofouling Glaucoma Micro-shunt.

    Science.gov (United States)

    Harake, Ryan S; Ding, Yuzhe; Brown, J David; Pan, Tingrui

    2015-10-01

    Glaucoma, one of the leading causes of irreversible blindness, is a progressive neurodegenerative disease. Chronic elevated intraocular pressure (IOP), a prime risk factor for glaucoma, can be treated by aqueous shunts, implantable devices, which reduce IOP in glaucoma patients by providing alternative aqueous outflow pathways. Although initially effective at delaying glaucoma progression, contemporary aqueous shunts often lead to numerous complications and only 50% of implanted devices remain functional after 5 years. In this work, we introduce a novel micro-device which provides an innovative platform for IOP reduction in glaucoma patients. The device design features an array of parallel micro-channels to provide precision aqueous outflow resistance control. Additionally, the device's microfluidic channels are composed of a unique combination of polyethylene glycol materials in order to provide enhanced biocompatibility and resistance to problematic channel clogging from biofouling of aqueous proteins. The microfabrication process employed to produce the devices results in additional advantages such as enhanced device uniformity and increased manufacturing throughput. Surface characterization experimental results show the device's surfaces exhibit significantly less non-specific protein adsorption compared to traditional implant materials. Results of in vitro flow experiments verify the device's ability to provide aqueous resistance control, continuous long-term stability through 10-day protein flow testing, and safety from risk of infection due to bacterial ingression.

  13. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a meta-analysis.

    Science.gov (United States)

    Wang, Shiming; Gao, Xiaoming; Qian, Nana

    2016-06-08

    The purpose of this study was to compare the efficacy and tolerability of the Ahmed glaucoma valve (AGV) implant and the Baerveldt implant for the treatment of refractory glaucoma. We comprehensively searched four databases, including PubMed, EMBASE, Web of Science, and the Cochrane Library databases, selecting the relevant studies. The continuous variables, namely, intraocular pressure reduction (IOPR) and a reduction in glaucoma medication, were pooled by the weighted mean differences (WMDs), and the dichotomous outcomes, including success rates and tolerability estimates, were pooled by the odds ratio (ORs). A total of 929 patients from six studies were included. The WMDs of the IOPR between the AGV implant and the Baerveldt implant were 1.58 [95 % confidence interval (CI): -2.99 to 6.15] at 6 months, -1.01 (95 % CI: -3.40 to 1.98) at 12 months, -0.54 (95 % CI: -4.89 to 3.82) at 24 months, and -0.47 (95 % CI: -3.29 to 2.35) at 36 months. No significant difference was detected between the two groups at any point in time. The pooled ORs comparing the AGV implant with the Baerveldt implant were 0.51 (95 % CI: 0.33 to 0.80) for the complete success rate and 0.67 (95 % CI: 0.50 to 0.91) for qualified success rate. The Baerveldt implant was associated with a reduction in glaucoma medication at -0.51 (95 % CI: -0.90 to -0.12). There were no significant differences between the AGV implant and the Baerveldt implant on the rates of adverse events. The Baerveldt implant is more effective in both its surgical success rate and reducing glaucoma medication, but it is comparable to the AGV implant in lowering IOP. Both implants may have comparable incidences of adverse events.

  14. Glaucoma

    Science.gov (United States)

    ... glaucoma Images Eye Slit-lamp exam Visual field test Glaucoma References Anderson DR. The optic nerve in glaucoma. In: Tasman W, Jaeger EA, eds. Duane's Ophthalmology 2013 . Philadelphia, PA: Lippincott Williams & Wilkins; 2013:vol 3, chap 48. Giaconi JA, ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma NEI ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ... Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and Aging ... Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: Glaucoma ... *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the ...

  20. Glaucoma

    Science.gov (United States)

    Glaucoma is a group of diseases that can damage the eye's optic nerve. It is a leading ... no symptoms at first. Without treatment, people with glaucoma will slowly lose their peripheral, or side vision. ...

  1. Comparison of the Ahmed and Baerveldt glaucoma shunts with combined cataract extraction.

    Science.gov (United States)

    Rai, Amrit S; Shoham-Hazon, Nir; Christakis, Panos G; Rai, Amandeep S; Ahmed, Iqbal Ike K

    2018-04-01

    To compare the surgical outcomes of combined phacoemulsification with either Ahmed glaucoma valve (AGV) or Baerveldt glaucoma implant (BGI). Retrospective cohort study. A total of 104 eyes that underwent combined phacoemulsification with either AGV (PhacoAGV; n = 57) or BGI (PhacoBGI; n = 47) implantation. Failure was defined as uncontrolled intraocular pressure (IOP; glaucoma surgery, vision-threatening complications, or progression to no-light-perception vision. The PhacoAGV group was older (p = 0.03), had poorer baseline visual acuity (VA; p = 0.001), and had fewer previous glaucoma surgeries (p = 0.04). Both groups had similar baseline IOP (PhacoAGV: 26.4 ± 8.3 mm Hg; PhacoBGI: 25.7 ± 7.3; p = 0.66) and glaucoma medications (PhacoAGV: 3.8 ± 1.0; PhacoBGI: 3.6 ± 1.5; p = 0.54). At 2 years, failure rates were 44% in the PhacoAGV group and 23% in the PhacoBGI group (p = 0.02). Both groups had similar mean IOP reduction (PhacoAGV: 45%; PhacoBGI: 47%, p = 0.67) and medication use reduction (PhacoAGV: 47%; PhacoBGI: 58%, p = 0.38). The PhacoBGI group had higher IOP and medication use up to 1 month (p glaucoma medications, or complication rates between PhacoAGV and PhacoBGI at 2 years, despite BGIs being implanted in patients at higher risk for failure. The PhacoAGV group had higher failure rates at 2 years. Both groups had significant improvements in VA due to removal of their cataracts. The PhacoBGI group required more interventions, but most of these were minor slit-lamp procedures. Copyright © 2018. Published by Elsevier Inc.

  2. Glaucoma

    Medline Plus

    Full Text Available ... Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... YouTube Videos » NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video for NEI YouTube Videos: ...

  4. Effect of glaucoma tube shunt parameters on cornea endothelial cells in patients with Ahmed valve implants.

    Science.gov (United States)

    Koo, Euna B; Hou, Jing; Han, Ying; Keenan, Jeremy D; Stamper, Robert L; Jeng, Bennie H

    2015-01-01

    The aim of this study was to assess the effect of various tube parameters on corneal endothelial cell density (ECD) after insertion of Ahmed valves. Thirty-nine eyes of 33 patients with previous superotemporal (ST) Ahmed valve implantation and 20 eyes of 13 participants with previous uncomplicated phacoemulsification and intraocular lens implantation but no history of glaucoma surgery were evaluated. Various tube parameters were measured with anterior segment optical coherence tomography. ST, central, and inferonasal (IN) ECD and pachymetry were measured. Endothelial cell loss and corneal thickness in the ST cornea was compared with those in the IN cornea. The mean age of the operated patients was 58 ± 22 years, and the mean time since glaucoma surgery was 2.5 ± 2.6 years. Thirty-two of the 39 study eyes were pseudophakic. The ECD was significantly lower in the ST endothelium than in the IN endothelium in eyes with glaucoma tube surgery (P < 0.001), although this relative reduction in ST ECD was not greater than that seen in pseudophakic control eyes (P = 0.16). In univariate analysis, tube angle relative to the cornea and distance from the tip of the tube to the cornea were significant risk factors for decreased ST endothelial cell loss when assessed relative to the IN ECD (P = 0.01 and P = 0.02, respectively). In multivariate analysis, only the distance of the tube tip to the cornea remained significantly associated with ST endothelial cell loss. Although this was a retrospective study with inherent limitations, tubes that are closer to the cornea seem to lead to increased loss of adjacent endothelial cells.

  5. Glaucoma

    Medline Plus

    Full Text Available ... Education Programs National Eye Health Education Program (NEHEP) Diabetic Eye Disease Education Program Glaucoma Education Program Low ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For ...

  6. Glaucoma

    Medline Plus

    Full Text Available ... Vision Education Program Hispanic/Latino Program Vision and Aging Program African American Program Training and Jobs Fellowships ... Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office ... Diabetic Eye Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino Program Vision and ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division ... Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Glaucoma Embedded video ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... Disease Education Program Glaucoma Education Program Low Vision Education Program Hispanic/Latino ... To search for current job openings visit HHS USAJobs Home » NEI YouTube ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence ... is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye Exam Dry Eye For Kids Glaucoma Healthy Vision Tips Leber Congenital Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » NEI YouTube Videos: Glaucoma Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract ...

  15. Glaucoma

    Science.gov (United States)

    ... considerably, providing more precise visual assessment tests and biologic markers for the disease. NIH-sponsored research led to the development of prostaglandins, a new class of drugs that offers excellent IOP control with fewer side effects. The Early Manifest Glaucoma ...

  16. Glaucoma Symptoms

    Science.gov (United States)

    ... up You can help find a cure for glaucoma Give now Signs & Symptoms The most common types ... have completely different symptoms. Symptoms of Open-Angle Glaucoma Most people who develop open-angle glaucoma don’ ...

  17. Tube shunt complications and their prevention.

    Science.gov (United States)

    Sarkisian, Steven R

    2009-03-01

    Glaucoma drainage devices (GDDs) have been generally accepted as a treatment of refractory glaucoma. GDDs have their own unique set of complications that are important to evaluate to prevent them. Tube shunts are typically used in eyes with refractory glaucoma. There is increased interest in studying the efficacy of GDDs. Most of the attention has been focused on comparing trabeculectomy with the Baerveldt implant (Advanced Medical Optics, Inc., Santa Anna, California, USA). The other leading implant is the Ahmed Glaucoma Valve. There are several retrospective studies comparing these two devices and a prospective study is ongoing. There is great interest in the complication rate of tube shunts and these have been published both retrospectively and prospectively. Complications such as hypotony, diplopia, strabismus, proptosis, tube erosion, failure, corneal decompensation, endophthalmitis, and visual loss are all important and some have recently been reviewed in the literature. Moreover, the use of glaucoma drainage implants in the pediatric population has been evaluated. Glaucoma drainage implants have been a powerful tool in our surgical fight to prevent blindness; however, they are not without complications or controversy.

  18. Novel surgical procedures in glaucoma: advances in penetrating glaucoma surgery.

    Science.gov (United States)

    Filippopoulos, Theodoros; Rhee, Douglas J

    2008-03-01

    Despite late modifications and enhancements, traditional penetrating glaucoma surgery is not without complications and is reserved for patients in whom pharmacologic treatment and/or laser trabeculoplasty do not suffice to control the intraocular pressure. This article critically reviews recent advances in penetrating glaucoma surgery with particular attention paid to two novel surgical approaches: ab interno trabeculectomy with the Trabectome and implantation of the Ex-PRESS shunt. Ab interno trabeculectomy (Trabectome) achieves a sustained 30% reduction in intraocular pressure by focally ablating and cauterizing the trabecular meshwork/inner wall of Schlemm's canal. It has a remarkable safety profile with respect to early hypotonous or infectious complications as it does not generate a bleb, but it can be associated with early postoperative intraocular pressure spikes that may necessitate additional glaucoma surgery. The Ex-PRESS shunt is more commonly implanted under a partial thickness scleral flap, and appears to have similar efficacy to standard trabeculectomy offering some advantages with respect to the rate of early complications related to hypotony. Penetrating glaucoma surgery will continue to evolve. As prospective randomized clinical trials become available, we will determine the exact role of these surgical techniques in the glaucoma surgical armamentarium.

  19. Facts about Glaucoma

    Science.gov (United States)

    ... Information » Glaucoma » Facts About Glaucoma Listen Facts About Glaucoma This information was developed by the National Eye ... is the best person to answer specific questions. Glaucoma Defined What is Glaucoma? Glaucoma is a group ...

  20. Glaucoma: Symptoms and Causes

    Science.gov (United States)

    ... types of glaucoma include the following: Open-angle glaucoma Open-angle glaucoma is the most common form ... re even aware of a problem. Angle-closure glaucoma Angle-closure glaucoma, also called closed-angle glaucoma, ...

  1. Glaucoma (image)

    Science.gov (United States)

    Glaucoma is a condition of increased fluid pressure inside the eye. The increased pressure causes compression of ... nerve which can eventually lead to nerve damage. Glaucoma can cause partial vision loss, with blindness as ...

  2. Glaucoma Foundation

    Science.gov (United States)

    ... Options: SIZE CONTRAST Search Home About TGF About Glaucoma About Exfoliation Syndrome Research Center Contact Us Get ... tear glands, and a common preservative in many glaucoma medications can worsen the symptoms. The main treatment ...

  3. Glaucoma Research Foundation

    Science.gov (United States)

    ... born with glaucoma. Read her story » Learn About Glaucoma Glaucoma is a complicated disease in which damage ... Christopher doesn't ever want to go blind » Glaucoma 360 Glaucoma 360 — three days of events uniting ...

  4. Equine Glaucoma.

    Science.gov (United States)

    Michau, Tammy Miller

    2017-12-01

    Glaucoma is a multifactorial neurodegenerative ocular disease leading to progressive loss of retinal ganglion cells and their axons that form the optic nerve, causing blindness. Knowledge of the pathogenesis and development of equine glaucoma is in its infancy compared with human glaucoma. Glaucoma occurs most commonly secondary to uveitis and may be underdiagnosed or misdiagnosed in horses suffering from uveitis. Recognition and clinical diagnosis of glaucoma in the horse is improved with clinician awareness and the availability of handheld tonometers. Therapy for glaucoma is aimed at decreasing aqueous humor production through medical and surgical means. Even with therapy, long-term prognosis for vision is poor. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. What Is Glaucoma?

    Science.gov (United States)

    ... Stories Español Eye Health / Eye Health A-Z Glaucoma Sections What Is Glaucoma? What Are the Symptoms ... Diagnosis Glaucoma Treatment Glaucoma Vision Simulator What Is Glaucoma? Leer en Español: ¿Qué es el glaucoma? Written ...

  6. Congenital Intrahepatic Portosystemic Shunts

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woong Hee; Kim, Young Tong; Jou, Sung Shick; Shin, Hyeong Cheol [Soonchunhyang University, Asan (Korea, Republic of)

    2008-12-15

    Intrahepatic portosystemic shunts are an anomalous connection between the portal vein and hepatic vein/IVC, which may be either congenital or acquired secondary to liver cirrhosis or portal hypertension. Cases of congenital intrahepatic shunts are usually encountered in children and may spontaneously resolve. We report 5 cases of congenital intrahepatic portosystemic shunts in neonates and an adult

  7. Glaucoma, Open-Angle

    Science.gov (United States)

    ... Home » Statistics and Data » Glaucoma, Open-angle Listen Glaucoma, Open-angle Open-angle Glaucoma Defined In open-angle glaucoma, the fluid passes ... 2010 2010 U.S. Age-Specific Prevalence Rates for Glaucoma by Age and Race/Ethnicity The prevalence of ...

  8. Glaucoma: Symptoms, Diagnosis & Treatment

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Symptoms, Treatment and Research Past Issues / Spring 2015 ... vision, without any pain. Photo courtesy of NEI Glaucoma Symptoms At first, open-angle glaucoma has no ...

  9. Get Tested for Glaucoma!

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Get Tested for Glaucoma! Past Issues / Fall 2009 Table of Contents Taylor ... aoa.org/ When were you finally diagnosed with glaucoma? Not until 1969, after a game of basketball. ...

  10. [Shunt and short circuit].

    Science.gov (United States)

    Rangel-Abundis, Alberto

    2006-01-01

    Shunt and short circuit are antonyms. In French, the term shunt has been adopted to denote the alternative pathway of blood flow. However, in French, as well as in Spanish, the word short circuit (court-circuit and cortocircuito) is synonymous with shunt, giving rise to a linguistic and scientific inconsistency. Scientific because shunt and short circuit made reference to a phenomenon that occurs in the field of the physics. Because shunt and short circuit are antonyms, it is necessary to clarify that shunt is an alternative pathway of flow from a net of high resistance to a net of low resistance, maintaining the stream. Short circuit is the interruption of the flow, because a high resistance impeaches the flood. This concept is applied to electrical and cardiovascular physiology, as well as to the metabolic pathways.

  11. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  12. Ventriculoperitoneal Shunt Migration

    Directory of Open Access Journals (Sweden)

    Justin P Puller

    2017-01-01

    Full Text Available History of present illness: A 40-year-old female presented to our ED with left upper abdominal pain and flank pain. The pain had begun suddenly 2 hours prior when she was reaching into a freezer to get a bag of frozen vegetables. She described the pain as sharp, constant, severe, and worse with movements and breathing. The pain radiated to the left shoulder. On review of systems, the patient had mild dyspnea and nausea. She denied fever, chills, headache, vision changes, vomiting, or urinary symptoms. Her medical history was notable for obstructive sleep apnea, gastroesophageal reflux disease, arthritis, fibromyalgia, depression, obesity, and idiopathic intracranial hypertension. For the latter, she had a VP (ventriculoperitoneal shunt placed 14 years prior to this visit. She had a history of 2 shunt revisions, the most recent 30 days before this ED visit. Significant findings: An immediate post-op abdominal x-ray performed after the patient’s VP shunt revision 30 days prior to this ED visit reveals the VP shunt tip in the mid abdomen. A CT of the abdomen performed on the day of the ED visit reveals the VP shunt tip interposed between the spleen and the diaphragm. Discussion: VP shunts have been reported to migrate to varied locations in the thorax and abdomen. Incidence of abdominal complications of VP shunt placement ranges from 10%-30%, and can include pseudocyst formation, migration, peritonitis, CSF ascites, infection, and viscus perforation. Incidence of distal shunt migration is reported as 10%, and most previously reported cases occurred in pediatric patients.1 A recent retrospective review cited BMI greater than thirty and previous shunt procedure as risk factors for distal shunt migration.2 The patient in the case presented had a BMI of 59 and 3 previous shunt procedures.

  13. Resident-performed Ex-PRESS shunt implantation versus trabeculectomy.

    Science.gov (United States)

    Seider, Michael I; Rofagha, Soraya; Lin, Shan C; Stamper, Robert L

    2012-09-01

    To compare outcomes between resident-performed trabeculectomy and Ex-PRESS shunt implantation. A consecutive cohort of 36 Ex-PRESS shunt implantations and 57 trabeculectomies (1 eye/patient) performed by resident surgeons in their third year of ophthalmic training at the University of California, San Francisco and at the San Francisco Veterans Administration Hospital, under the supervision of a single glaucoma fellowship-trained surgeon were included in this study. Eyes with PRESS shunt groups at all follow-up points. On average, the Ex-PRESS shunt group required significantly less ocular antihypertensive medication to control IOP at 3 months postoperative (P=0.01), but no difference was found at 6 months or 1 year (all, P≥0.28). A larger proportion of Ex-PRESS shunt patients had good IOP control without medication at 3 (P=0.057) and 6 months (P=0.076) postoperatively. No difference was found in the rates of sight-threatening complications between groups (all, P≥0.22). In the hands of ophthalmology residents in their third year of training, the trabeculectomy and Ex-PRESS shunt implantation procedures perform comparably in terms of postoperative IOP control, reduction in patient dependence on ocular antihypertensive medications, and risk of complication in our population.

  14. Transjugular intrahepatic portosystemic shunt

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Han, Joon Koo; Chung, Jin Wook; Han, Man Chung [Seoul National University College of Medicidne, Seoul (Korea, Republic of)

    1992-05-15

    As a new interventional procedure for the control of variceal bleeding, a portosystemic shunt can be established with the installment of metallic stent through the transjugular approach. In order to evaluate the clinical usefulness of the procedure, transjugular intrahepatic portosystemic shunt procedure were performed in 5 patients with variceal bleeding due to liver cirrhosis. The metallic stents were mainly a self expandable Wallstent (Schneider, Switzerland), An 8 to 10 mm shunt was formed by the insertion of the stent and balloon dilatation after puncture of the proximal portal vein from the right or middle hepatic vein. The patency of the shunt was proven by portography after the procedure. The portal pressure measured in 3 patients before and after the procedure improved with decrease from 31 mmHg to 25 mmHg. The procedure failed in 1 patient due to pre-existing portal vein thrombosis. During the follow-up period from 1 month to 4 months, shunts were patent in all 4 patients. However, hepatic encephalopathy occurred in one patient one week following the procedure. Though the follow-up period was not long enough for full evaluation, we found the transjugular intrahepatic portosystemic shunt was a safe and effective procedure for the control of variceal bleeding by lowering the portal pressure. For the appropriate application for this procedure, the optimal size of the shunt and optical degree of the resultant decompression are yet to be determined in the future.

  15. Traumatic glaucoma due to paintball injuries: A case series

    Directory of Open Access Journals (Sweden)

    Kelly M. Lee

    2017-12-01

    Full Text Available Purpose: To study the management and outcomes of patients with paintball injuries resulting in traumatic glaucoma. Methods: A retrospective review was performed, identifying four patients with a confirmed diagnosis of traumatic glaucoma secondary to paintball sports. Results: Four male patients with paintball gun injuries presented with a mean follow-up time of 51 months after the date of injury. The mean age was 23.5 ± 18.6 years. Three patients presented with blunt trauma, while one patient had a ruptured globe. Presenting visual acuity (VA was hand motions in three of the patients and no light perception in the fourth patient. All patients were diagnosed with traumatic glaucoma and treated with glaucoma medications during their follow-up. Two patients received tube shunts to control intraocular pressures (IOPs. At the time of most recent follow-up, three patients had elevated IOPs and were not on any medications. VA at the last follow-up was 20/400 or worse. Conclusions: Traumatic glaucoma can be managed with surgical and medical interventions, while VA usually does not return to baseline levels prior to the injury. Prognostic predictors can be used to guide treatment and identify patients who should be closely followed. Because the presentation and onset is widely variable, follow-up and screening is crucial even years after the injury. Keywords: Paintball, Ocular trauma, Glaucoma, Secondary glaucoma

  16. Hydrocephalus and Shunts

    Science.gov (United States)

    ... of a problem. Because of the complexity, a neurosurgeon is the best person to diagnosis and treat ... type of shunt is best for whom. So neurosurgeons usually pick ones that they think are best. ...

  17. Flux shunts for undulators

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Hassenzahl, W.V.

    1993-05-01

    Undulators for high-performance applications in synchrotron-radiation sources and periodic magnetic structures for free-electron lasers have stringent requirements on the curvature of the electron's average trajectory. Undulators using the permanent magnet hybrid configuration often have fields in their central region that produce a curved trajectory caused by local, ambient magnetic fields such as those of the earth. The 4.6 m long Advanced Light Source (ALS) undulators use flux shunts to reduce this effect. These flux shunts are magnetic linkages of very high permeability material connecting the two steel beams that support the magnetic structures. The shunts reduce the scalar potential difference between the supporting beams and carry substantial flux that would normally appear in the undulator gap. Magnetic design, mechanical configuration of the flux shunts and magnetic measurements of their effect on the ALS undulators are described

  18. Glaucoma in Asian Populations

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Glaucoma In Asian Populations email Send this article to ... lower than in their Asian counterparts. Normal Tension Glaucoma affects Japanese Japanese populations, however, have a substantially ...

  19. African Americans and Glaucoma

    Science.gov (United States)

    ... Us Donate In This Section African Americans and Glaucoma email Send this article to a friend by ... and eventually, in developing more effective treatments. Does glaucoma treatment differ? Although treatment varies for all individuals, ...

  20. Screening for Glaucoma

    Science.gov (United States)

    Understanding Task Force Recommendations Screening for Glaucoma The U.S. Preventive Services Task Force (Task Force) has issued a final recommendation statement on Screening for Glaucoma . This final recommendation statement ...

  1. Five Common Glaucoma Tests

    Science.gov (United States)

    ... About Us Donate In This Section Five Common Glaucoma Tests en Español email Send this article to ... year or two after age 35. A Comprehensive Glaucoma Exam To be safe and accurate, five factors ...

  2. Pathophysiology of shunt dysfunction in shunt treated hydrocephalus

    DEFF Research Database (Denmark)

    Blegvad, C.; Skjolding, A D; Broholm, H

    2013-01-01

    We hypothesized that shunt dysfunction in the ventricular catheter and the shunt valve is caused by different cellular responses. We also hypothesized that the cellular responses depend on different pathophysiological mechanisms....

  3. A rare cause of pediatric urinary incontinence: Ventriculoperitoneal shunt with bladder perforation

    Directory of Open Access Journals (Sweden)

    Manuel C See IV

    2016-04-01

    Full Text Available We present a case of 2-year-old boy with long term dysuria and intermittent incontinence, and new onset of fever and headache. Significant past medical history includes congenital hydrocephalus with a ventriculoperitoneal shunt placement two years prior to consult. On physical examination, a tubular structure was noted underneath the prepuce suspected to be the distal tip of ventriculoperitoneal shunt, which was confirmed by kidney, ureter and bladder (KUB X-ray and CT scan. Patient was treated with a novel approach of extraperitoneal removal of ventriculoperitoneal shunt distal tip with cystorrhaphy via a low transverse pfannenstiel incision, separate left ventriculostomy tube insertion and complete removal of ventriculoperitoneal shunt from the right ventricle. This report accounts a rare pediatric case with ventriculoperitoneal shunt perforation into a normal bladder successfully treated with mini-open surgery.

  4. Shunts to divert aqueous humor to distant epithelialized cavities after keratoprosthesis surgery.

    Science.gov (United States)

    Dohlman, Claes H; Grosskreutz, Cynthia L; Chen, Teresa C; Pasquale, Louis R; Rubin, Peter A D; Kim, Eva C; Durand, Marlene

    2010-02-01

    Glaucoma is a frequent and often severe problem in patients needing keratoprosthesis (KPro) surgery. Standard glaucoma shunts in these cases often develop a very dense capsule that obstructs flow and causes intraocular pressure elevation. Therefore, we developed shunts that deliver aqueous to distant epithelialized cavities where an obstructing capsule is less likely to form. In this retroactive study of such shunts, the risk of postoperative infection (especially endophthalmitis) has been assessed. Ahmed shunts were connected with a tube to the lacrimal sac or ethmoid sinuses. In subsequent designs the polypropylene plate was eliminated, the valve was enclosed and a distal tube added (New World Medical Inc, Rancho Cucamonga, CA). The latter shunts were connected to the maxillary sinus or lower lid fornix. Between 2001 and 2005 the devices were implanted in 34 patients with very severe ocular disease. (31 had KPro implanted). Thus, the distal tube was led to the lacrimal sac (2 cases), to the ethmoid sinuses (6), to the maxillary sinus (16 cases), and to the lower lid fornix (10 cases). The patients were followed for cumulatively 145 shunt years, with a mean follow-up of 4 years and 3 months. They were instructed to administer low-dose topical antibiotics indefinitely. Only 1 case of acute bacterial endophthalmitis occurred, thus an incidence of 0.7% per shunt year. A slow-growing Mycobacterium was cultured in a disintegrating eye and 1 bacterial maxillary sinusitis occurred, both in autoimmune diseases. Three valves became exposed and had to be removed (1 replaced). Four eyes developed hypotony, probably from valve failure. The shunt arrangement, which connects the anterior chamber to potentially microbe-populated cavities or to the lower lid fornix and its flora, might be suspected to allow rapid retrograde invasion of infective agents, resulting in endophthalmitis. In this series of KPro patients, however, the incidence of severe infection was very low, in fact

  5. SQUID developments for the gravitational wave antenna MiniGRAIL

    NARCIS (Netherlands)

    Pleikies, J.; Usenko, O.; Kuit, K.H.; Flokstra, Jakob; de Waard, A.; de Waard, A.; Frossati, G.

    2007-01-01

    We designed two different sensor SQUIDs for the readout of the resonant mass gravitational wave detector MiniGRAIL. Both designs have integrated input inductors in the order of 1.5 muH and are planned for operation in the mK temperature range. Cooling fins were added to the shunt resistors. The

  6. Minimally invasive glaucoma surgery: current status and future prospects

    Directory of Open Access Journals (Sweden)

    Richter GM

    2016-01-01

    Full Text Available Grace M Richter,1,2 Anne L Coleman11UCLA Stein Eye Institute, Department of Ophthalmology, University of California, Los Angeles, CA, USA; 2USC Eye Institute, Department of Ophthalmology, Keck School of Medicine of University of Southern California, Los Angeles, CA, USAAbstract: Minimally invasive glaucoma surgery aims to provide a medication-sparing, conjunctival-sparing, ab interno approach to intraocular pressure reduction for patients with mild-to-moderate glaucoma that is safer than traditional incisional glaucoma surgery. The current approaches include: increasing trabecular outflow (Trabectome, iStent, Hydrus stent, gonioscopy-assisted transluminal trabeculotomy, excimer laser trabeculotomy; suprachoroidal shunts (Cypass micro-stent; reducing aqueous production (endocyclophotocoagulation; and subconjunctival filtration (XEN gel stent. The data on each surgical procedure for each of these approaches are reviewed in this article, patient selection pearls learned to date are discussed, and expectations for the future are examined. Keywords: MIGS, microincisional glaucoma surgery, trabecular stent, Schlemm’s canal, suprachoroidal shunt, ab interno

  7. Simultaneous Implantation of an Ahmed and Baerveldt Glaucoma Drainage Device for Uncontrolled Intraocular Pressure in Advanced Glaucoma.

    Science.gov (United States)

    Rao, Veena S; Christenbury, Joseph; Lee, Paul; Allingham, Rand; Herndon, Leon; Challa, Pratap

    2017-02-01

    To evaluate efficacy and safety of a novel technique, simultaneous implantation of Ahmed and Baerveldt shunts, for improved control of intraocular pressure (IOP) in advanced glaucoma with visual field defects threatening central fixation. Retrospective case series; all patients receiving simultaneous Ahmed and Baerveldt implantation at a single institution between October 2004 and October 2009 were included. Records were reviewed preoperatively and at postoperative day 1, week 1, month 1, month 3, month 6, year 1, and yearly until year 5. Outcome measures included IOP, best-corrected visual acuity, visual field mean deviation, cup to disc ratio, number of glaucoma medications, and complications. Fifty-nine eyes were identified; mean (±SD) follow-up was 26±23 months. Primary open-angle glaucoma was most common (n=37, 63%). Forty-six eyes (78%) had prior incisional surgery. Mean preoperative IOP was 25.5±9.8 mm Hg. IOP was reduced 50% day 1 (Pglaucoma tube implantation with effects persisting over postoperative year 1 and up to year 5. Complications were higher than that seen in reports of single shunt implantation, which may be explained by patient complexity in this cohort. This technique may prove a promising novel approach for management of uncontrolled IOP in advanced glaucoma.

  8. Glaucoma Medication Preferences among Glaucoma Specialists in Mexico

    OpenAIRE

    Lazcano-Gomez, Gabriel; Alvarez-Ascencio, Daniela; Haro-Zuno, Cindy; Turati-Acosta, Mauricio; Garcia-Huerta, Magdalena; Jimenez-Arroyo, Jesus; Castañeda-Diez, Rafael; Castillejos-Chevez, Armando; Gonzalez-Salinas, Roberto; Dominguez-Dueñas, Francisca; Jimenez-Roman, Jesus

    2017-01-01

    Aim To determine the glaucoma specialists’ preferences for the different brands of topical glaucoma medications available in Mexico. Materials and methods A web-based survey was sent to 150 board-certified glaucoma specialists in Mexico, with 14 questions related to brand preferences for all glaucoma medications available in Mexico. Participants were asked to select each glaucoma medication class by brand and to state the factors leading to their choice. Results Data from 111 (74%) glaucoma s...

  9. Outcomes of glaucoma reoperations in the Tube Versus Trabeculectomy (TVT) Study.

    Science.gov (United States)

    Saheb, Hady; Gedde, Steven J; Schiffman, Joyce C; Feuer, William J

    2014-06-01

    To describe the incidence and outcomes of reoperations for glaucoma in the Tube Versus Trabeculectomy (TVT) Study. Cohort study of patients in a multicenter randomized clinical trial. The TVT Study enrolled 212 patients with medically uncontrolled glaucoma who had previous cataract and/or glaucoma surgery. Randomization assigned 107 patients to surgery with a tube shunt (350 mm(2) Baerveldt glaucoma implant) and 105 patients to trabeculectomy with mitomycin C (0.4 mg/mL for 4 minutes). Data were analyzed from patients who failed their assigned treatment and had additional glaucoma surgery. Outcome measures included intraocular pressure (IOP), use of glaucoma medications, visual acuity, surgical complications, and failure (IOP >21 mm Hg or not reduced by 20%, IOP ≤5 mm Hg, additional glaucoma surgery, or loss of light perception vision). Additional glaucoma surgery was performed in 8 patients in the tube group and 18 patients in the trabeculectomy group in the TVT Study, and the 5-year cumulative reoperation rate was 9% in the tube group and 29% in the trabeculectomy group (P = .025). Follow-up (mean ± SD) after additional glaucoma surgery was 28.0 ± 16.0 months in the tube group and 30.5 ± 20.4 months in the trabeculectomy group (P = .76). At 2 years after a glaucoma reoperation, IOP (mean ± SD) was 15.0 ± 5.5 mm Hg in the tube group and 14.4 ± 6.6 mm Hg in the trabeculectomy group (P = .84). The number of glaucoma medications (mean ± SD) after 2 years of follow-up was 1.1 ± 1.3 in the tube group and 1.4 ± 1.4 in the trabeculectomy group (P = .71). The cumulative probability of failure at 1, 2, 3, and 4 years after additional glaucoma surgery was 0%, 43%, 43%, and 43%, respectively, in the tube group, and 0%, 9%, 20%, and 47% in the trabeculectomy group (P = .28). Reoperations to manage complications were required in 1 patient in the tube group and 5 patients in the trabeculectomy group (P = .63). The rate of reoperation for glaucoma was higher following

  10. Investigating PID Shunting in Polycrystalline Silicon Modules via Multiscale, Multitechnique Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Steven P [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Moseley, John [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Norman, Andrew [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Johnston, Steven [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Al-Jassim, Mowafak M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stokes, Adam [Colorado School of Mines; Gorman, Brian [Colorado School of Mines

    2018-02-27

    We investigated the potential-induced degradation (PID) shunting mechanism in multicrystalline-silicon photovoltaic modules by using a multiscale, multitechnique characterization approach. Both field-stressed modules and laboratory-stressed mini modules were studied. We used photoluminescence, electroluminescence, and dark lock-in thermography imaging to identify degraded areas at the module scale. Small samples were then removed from degraded areas, laser marked, and imaged by scanning electron microscopy. We used simultaneous electron-beam induced current imaging and focused ion beam milling to mark around PID shunts for chemical analysis by time-of-flight secondary-ion mass spectrometry or to isolate individual shunt defects for transmission electron microscopy and atom-probe tomography analysis. By spanning a range of 10 orders of magnitude in size, this approach enabled us to investigate the root-cause mechanisms for PID shunting. We observed a direct correlation between recombination active shunts and sodium content. The sodium content in shunted areas peaks at the SiNX/Si interface and is consistently observed at a concentration of 0.1% to 2% in shunted areas. Analysis of samples subjected to PID recovery, either activated by electron beam or thermal effects only, reveals that recovery of isolated shunts correlates with diffusion of sodium out of the structural defects to the silicon surface. We observed the role of oxygen and chlorine in PID shunting and found that those species - although sometimes present in structural defects where PID shunting was observed - do not play a consistent role in PID shunting.

  11. [Music and Glaucoma].

    Science.gov (United States)

    Plange, N

    2017-02-01

    Music may have multiple influences on the human organism. A possible therapeutic effect for patients with glaucoma has been postulated, aside from the known impact of music on the cardiovascular system, psychogenic effects and a short-term improvement in mental performance (Mozart effect). The higher level of mental stress in patients with glaucoma and type-A personality behaviour may be related to higher intraocular pressure in patients with glaucoma. Relaxing music may have a positive impact in these patients, related to a reduction in intraocular pressure or its fluctuations. However, only limited data exist on the effects of music on intraocular pressure. No clinical studies have yet been performed to investigate the effect of music or music therapy on glaucoma progression. The music of Mozart may influence visual field examinations, possibly due to a positive short term effect on mental performance. This factor needs to be addressed in studies dealing with the effect of music in glaucoma. The relevance of intraocular pressure increases in professional wind instrument players is controversial. An increased level of care might be advisable in patients with advanced glaucoma. The influences of music on humans, altered personality profiles in patients with glaucoma and the studies showing some effect of stress on intraocular pressure stress the relevance of psychological support for glaucoma patients, who are confronted with a disease with a high longterm risk of blindness. Georg Thieme Verlag KG Stuttgart · New York.

  12. Nanotechnology Applications for Glaucoma.

    Science.gov (United States)

    Cetinel, Sibel; Montemagno, Carlo

    2016-01-01

    Glaucoma is the second leading cause of blindness worldwide, and the antiglaucoma treatments currently available suffer from various complications. Nanotechnology-based treatments show a great deal of promise in overcoming these complications and form the basis for next-generation glaucoma treatment strategies, with the help of applications such as controlled release, targeted delivery, increased bioavailability, diffusion limitations, and biocompatibility. Significant progress has been made in nanomedicine in the efficiency of antiglaucoma medications, nanofabrication systems such as microelectromechanical systems that remove the limitations of nanodevices, and tissue regeneration vesicles for developing glaucoma treatments not based on intraocular pressure. With the use of these advanced technologies, the prevention of glaucoma-induced blindness will be possible in the near future. Herein, we reviewed the recent advances in nanotechnology-based treatment strategies for glaucoma.

  13. Subinternal limiting membrane hemorrhage post-Ahmed glaucoma valve in vitrectomized eye

    Directory of Open Access Journals (Sweden)

    Bhuvan Chanana

    2018-01-01

    Full Text Available Glaucoma drainage devices are mostly used for refractory glaucoma. Early postoperative complications include flat anterior chamber, choroidal effusion, and suprachoroidal hemorrhage. An 8-year-old male patient with a prior history of vitreous surgery for traumatic vitreous hemorrhage, presented to us with angle recession glaucoma in his right eye. His intraocular pressure (IOP was 44 mmHg despite maximum antiglaucoma medication. Ahmed glaucoma valve (AGV surgery was performed to control his IOP. In the early postoperative period, the patient developed premacular subinternal limiting membrane (ILM hemorrhage, which did not resolve even after 4 weeks. Vitreoretinal intervention involving removal of the thickened ILM and sub-ILM bleed had to be performed. To the best of our knowledge, no case has been reported with sub-ILM bleed post aqueous humor shunts. Here, we report a case of premacular sub-ILM bleed following AGV in vitrectomized eye.

  14. Ventriculoperitoneal shunt infections in children

    African Journals Online (AJOL)

    1991-02-02

    Feb 2, 1991 ... shunts: epidemiology, clinical manifestations and therapy.] Infecr Vis 1975;. 13: 543-552. 4. Odio C, McCracken GH jun, Nelson JD. CSF shunt infections in pediatrics, a seven-year experience. Am] Dis Child 1984; 138: 1103-1108. 5. Meirovitch J, Kitai-Cohen Y, Keren G, Fiendler G, Rubinstein E. Cerebro-.

  15. Oculo-peritoneal shunt: draining aqueous humor to the peritoneum

    Directory of Open Access Journals (Sweden)

    Ana Maldonado-Junyent

    2015-04-01

    Full Text Available In 2010, there were estimated to be approximately 60.5 million people with glaucoma. This number is expected to increase to 79.6 million by 2020. In 2010, there were 8.4 million people with bilateral blindness caused by glaucoma, and this number is expected in increase to 11.2 million by 2020. Filtering implants are special devices that have been developed to reduce intraocular pressure in patients with refractory glaucoma. The success rate of these implants is relatively low, and they continue to fail over time. To avoid failure caused by the formation of scar tissue around the implants, attempts have been made to drain the aqueous humor to various sites, including the venous system, lacrimal sac, sinuses, and conjunctival fornix. Recently, a system to shunt aqueous humor from the anterior chamber to the peritoneum has been developed. The surgical technique involved in this system is a modification of the technique currently used by neurosurgeons for the treatment of hydrocephalus. We present the first case operated using this technique.

  16. Congenital extrahepatic portosystemic shunts

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S. [Department of Diagnostic Imaging, Hospital for Sick Children, 555 University Avenue, M5G 1X8, Toronto, Ontario (Canada)

    2003-09-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  17. Congenital extrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Murray, Conor P.; Yoo, Shi-Joon; Babyn, Paul S.

    2003-01-01

    A congenital extrahepatic portosystemic shunt (CEPS) is uncommon. A type 1 CEPS exists where there is absence of intrahepatic portal venous supply and a type 2 CEPS where this supply is preserved. The diagnosis of congenital portosystemic shunt is important because it may cause hepatic encephalopathy. To describe the clinical and imaging features of three children with CEPS and to review the cases in the published literature. The diagnostic imaging and medical records for three children with CEPS were retrieved and evaluated. An extensive literature search was performed. Including our cases, there are 61 reported cases of CEPS, 39 type 1 and 22 type 2. Type 1 occurs predominantly in females, while type 2 shows no significant sexual preponderance. The age at diagnosis ranges from 31 weeks of intrauterine life to 76 years. Both types of CEPS have a number of associations, the most common being nodular lesions of the liver (n=25), cardiac anomalies (n=19), portosystemic encephalopathy (n=10), polysplenia (n=9), biliary atresia (n=7), skeletal anomalies (n=5), and renal tract anomalies (n=4). MRI is recommended as an important means of diagnosing and classifying cases of CEPS and examining the associated cardiovascular and hepatic abnormalities. Screening for CEPS in patients born with polysplenia is suggested. (orig.)

  18. Glaucoma: Screening Can Save Your Sight!

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Glaucoma: Screening Can Save Your Sight! Past Issues / Fall 2009 Table of Contents People with glaucoma see the world through a tunnel. Glaucoma is ...

  19. Subacute bacterial endocarditis and subsequent shunt nephritis from ventriculoatrial shunting 14 years after shunt implantation

    DEFF Research Database (Denmark)

    Burström, Gustav; Andresen, Morten; Bartek, Jiri Jr.

    2014-01-01

    of causing subacute bacterial endocarditis and subsequent shunt nephritis. The patient was successfully treated with antibiotics combined with ventriculoatrial shunt removal and endoscopic third ventriculocisternostomy (VCS). This case illustrates the nowadays rare, but potentially severe complication...... of subacute bacterial endocarditis and shunt nephritis. It also exemplifies the VCS as an alternative to implanting foreign shunt systems for CSF diversion....

  20. Daily Life with Glaucoma

    Science.gov (United States)

    ... Size Small Text Medium Text Large Text Contrast Dark on Light Light on Dark Donate Search Menu Donate What is Glaucoma? Care ... Low Vision Resources Medication Guide Resources on the Web » See All Articles Where the Money Goes Have ...

  1. Glaucoma in developing countries

    Directory of Open Access Journals (Sweden)

    Ravi Thomas

    2012-01-01

    Full Text Available Objective: To describe the background and strategy required for the prevention of blindness from glaucoma in developing countries. Materials and Methods: Extrapolation of existing data and experience in eye care delivery and teaching models in an unequally developed country (India are used to make recommendations. Results: Parameters like population attributable risk percentage indicate that glaucoma is a public health problem but lack of simple diagnostic techniques and therapeutic interventions are barriers to any effective plan. Case detection rather than population-based screening is the recommended strategy for detection. Population awareness of the disease is low and most patients attending eye clinics do not receive a routine comprehensive eye examination that is required to detect glaucoma (and other potentially blinding eye diseases. Such a routine is not taught or practiced by the majority of training institutions either. Angle closure can be detected clinically and relatively simple interventions (including well performed cataract surgery can prevent blindness from this condition. The strategy for open angle glaucoma should focus on those with established functional loss. Outcomes of this proposed strategy are not yet available. Conclusions: Glaucoma cannot be managed in isolation. The objective should be to detect and manage all potential causes of blindness and prevention of blindness from glaucoma should be integrated into existing programs. The original pyramidal model of eye care delivery incorporates this principle and provides an initial starting point. The routine of comprehensive eye examination in every clinic and its teaching (and use in residency programs is mandatory for the detection and management of potentially preventable blinding pathology from any cause, including glaucoma. Programs for detection of glaucoma should not be initiated unless adequate facilities for diagnosis and surgical intervention are in place and

  2. Glaucoma after corneal replacement.

    Science.gov (United States)

    Baltaziak, Monika; Chew, Hall F; Podbielski, Dominik W; Ahmed, Iqbal Ike K

    Glaucoma is a well-known complication after corneal transplantation surgery. Traditional corneal transplantation surgery, specifically penetrating keratoplasty, has been slowly replaced by the advent of new corneal transplantation procedures: primarily lamellar keratoplasties. There has also been an emergence of keratoprosthesis implants for eyes that are high risk of failure with penetrating keratoplasty. Consequently, there are different rates of glaucoma, pathogenesis, and potential treatment in the form of medical, laser, or surgical therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Update on Minimally Invasive Glaucoma Surgery (MIGS and New Implants

    Directory of Open Access Journals (Sweden)

    Lívia M. Brandão

    2013-01-01

    Full Text Available Traditional glaucoma surgery has been challenged by the advent of innovative techniques and new implants in the past few years. There is an increasing demand for safer glaucoma surgery offering patients a timely surgical solution in reducing intraocular pressure (IOP and improving their quality of life. The new procedures and devices aim to lower IOP with a higher safety profile than fistulating surgery (trabeculectomy/drainage tubes and are collectively termed “minimally invasive glaucoma surgery (MIGS.” The main advantage of MIGS is that they are nonpenetrating and/or bleb-independent procedures, thus avoiding the major complications of fistulating surgery related to blebs and hypotony. In this review, the clinical results of the latest techniques and devices are presented by their approach, ab interno (trabeculotomy, excimer laser trabeculotomy, trabecular microbypass, suprachoroidal shunt, and intracanalicular scaffold and ab externo (canaloplasty, Stegmann Canal Expander, suprachoroidal Gold microshunt. The drawback of MIGS is that some of these procedures produce a limited IOP reduction compared to trabeculectomy. Currently, MIGS is performed in glaucoma patients with early to moderate disease and preferably in combination with cataract surgery.

  4. Clinical Metabolomics and Glaucoma.

    Science.gov (United States)

    Barbosa-Breda, João; Himmelreich, Uwe; Ghesquière, Bart; Rocha-Sousa, Amândio; Stalmans, Ingeborg

    2018-01-01

    Glaucoma is one of the leading causes of irreversible blindness worldwide. However, there are no biomarkers that accurately help clinicians perform an early diagnosis or detect patients with a high risk of progression. Metabolomics is the study of all metabolites in an organism, and it has the potential to provide a biomarker. This review summarizes the findings of metabolomics in glaucoma patients and explains why this field is promising for new research. We identified published studies that focused on metabolomics and ophthalmology. After providing an overview of metabolomics in ophthalmology, we focused on human glaucoma studies. Five studies have been conducted in glaucoma patients and all compared patients to healthy controls. Using mass spectrometry, significant differences were found in blood plasma in the metabolic pathways that involve palmitoylcarnitine, sphingolipids, vitamin D-related compounds, and steroid precursors. For nuclear magnetic resonance spectroscopy, a high glutamine-glutamate/creatine ratio was found in the vitreous and lateral geniculate body; no differences were detected in the optic radiations, and a lower N-acetylaspartate/choline ratio was observed in the geniculocalcarine and striate areas. Metabolomics can move glaucoma care towards a personalized approach and provide new knowledge concerning the pathophysiology of glaucoma, which can lead to new therapeutic options. © 2017 S. Karger AG, Basel.

  5. Neuroprotection in glaucoma

    Directory of Open Access Journals (Sweden)

    Azadeh Doozandeh

    2016-01-01

    Full Text Available Glaucoma is a degenerative optic neuropathy characterized by retinal ganglion cell (RGC loss and visual field defects. It is known that in some glaucoma patients, death of RGCs continues despite intraocular pressure (IOP reduction. Neuroprotection in the field of glaucoma is defined as any treatment, independent of IOP reduction, which prevents RGC death. Glutamate antagonists, ginkgo biloba extract, neurotrophic factors, antioxidants, calcium channel blockers, brimonidine, glaucoma medications with blood regulatory effect and nitric oxide synthase inhibitors are among compounds with possible neuroprotective activity in preclinical studies. A few agents (such as brimonidine or memantine with neuroprotective effects in experimental studies have advanced to clinical trials; however the results of clinical trials for these agents have not been conclusive. Nevertheless, lack of compelling clinical evidence has not prevented the off-label use of some of these compounds in glaucoma practice. Stem cell transplantation has been reported to halt experimental neurodegenerative disease processes in the absence of cell replacement. It has been hypothesized that transplantation of some types of stem cells activates multiple neuroprotective pathways via secretion of various factors. The advantage of this approach is a prolonged and targeted effect. Important concerns in this field include the secretion of unwanted harmful mediators, graft survival issues and tumorigenesis. Neuroprotection in glaucoma, pharmacologically or by stem cell transplantation, is an interesting subject waiting for broad and multidisciplinary collaborative studies to better clarify its role in clinical practice.

  6. [OCT and neovascular glaucoma].

    Science.gov (United States)

    Bellotti, A; Labbé, A; Fayol, N; El Mahtoufi, A; Baudouin, C

    2007-06-01

    Neovascular glaucoma is a chronic and sight-threatening disease. Four different grades have been described. Anterior chamber optical coherence tomography (OCT) is a new imaging technique allowing the visualization of the anterior segment. The purpose of our study was to describe the appearance of the different neovascular glaucoma grades with the OCT in order to refine the clinical analysis of this disease. Eleven patients (nine men and two women) with different grades of neovascular glaucoma were analyzed in this study. Neovascular glaucoma complicated central retinal vein occlusion in seven patients and diabetic retinopathy in four patients. All patients had bilateral biomicroscopical examination and OCT analysis. OCT images and clinical examination were then compared. No modifications could be observed using OCT in patients with grade 1 neovascular glaucoma. For grade 2, a slightly hyper-reflective linear iris secondary to neovascularization was observed. For grade 3, OCT images showed a thickened hyper-reflective iridocorneal angle with possible iridocorneal synechiae. For grade 4, the iridocorneal angle was closed and associated with iris contraction and uveae ectropion. OCT is a new promising technique for the precise analysis of different grades of neovascular glaucoma. It certainly helps in the management of such cases.

  7. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.-D.

    1996-05-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole, and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors, and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model

  8. Quadrupole shunt experiments at SPEAR

    International Nuclear Information System (INIS)

    Corbett, W.J.; Hettel, R.O.; Nuhn, H.

    1997-01-01

    As part of a program to align and stabilize the SPEAR storage ring, a switchable shunt resistor was installed on each quadrupole to bypass a small percentage of the magnet current. The impact of a quadrupole shunt is to move the electron beam orbit in proportion to the off-axis beam position at the quadrupole and to shift the betatron tune. Initially, quadrupole shunts in SPEAR were used to position the electron beam in the center of the quadrupoles. This provided readback offsets for nearby beam position monitors and helped to steer the photon beams with low-amplitude corrector currents. The shunt-induced tune shift measurements were then processed in MAD to derive a lattice model. copyright 1997 American Institute of Physics

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... a stent is placed to keep the connection open and allow it to bring blood draining from ... veins within the liver. The shunt is kept open by the placement of a small, tubular metal ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  13. New Tool to Predict Glaucoma

    Science.gov (United States)

    ... In This Section A New Tool to Predict Glaucoma email Send this article to a friend by ... Close Send Thanks for emailing that article! Tweet Glaucoma can be difficult to detect and diagnose. Measurement ...

  14. Does Your Child Have Glaucoma?

    Science.gov (United States)

    ... Donate In This Section Does Your Child Have Glaucoma? email Send this article to a friend by ... a pediatric ophthalmologist. Signs and Symptoms of Childhood Glaucoma What to watch for in children under the ...

  15. Does Marijuana Help Treat Glaucoma?

    Science.gov (United States)

    ... time, reducing side vision. It sometimes leads to blindness. One cause of optic nerve damage in glaucoma ... high doses, can cause problems with short-term memory and concentration. As scientists learn more about glaucoma, ...

  16. [Uveitic Secondary Glaucoma].

    Science.gov (United States)

    Lommatzsch, Claudia; Heinz, Carsten

    2018-05-01

    An intraocular pressure increase with development of glaucomatous damage is a common complication of uveitis. The prevalence has a wide range depending on various factors such as the underlying uveitis type and the duration of the disease. Pathogenetically, a distinction must be made between a secondary angle closure component and the more frequently occurring open-angle glaucoma. In diagnostics, in addition to the clinical optic nerve head assessment, perimetry and tonometry, the use of imaging examination equipment, such as OCT and HRT, are recommended. In the context of uveitic glaucoma, it must be considered in the evaluation, because the glaucoma-typical changes are generally less pronounced or can be concealed by retinal swelling in comparison with other forms of glaucoma. Therapeutically, drug therapy in the form of eye drops continues to be a first-line recommendation, with the use of topical carbonic anhydrase inhibitors or beta-blockers primarily preferred, depending on the contraindications. An operative therapy follows after unsuccessful or inadequate conservative therapy: the adequate surgical technique depends on the respective finding and includes actually techniques such as filtering procedures and glaucoma drainage devices. Georg Thieme Verlag KG Stuttgart · New York.

  17. Failed Ventriculoperitoneal Shunt: Is Retrograde Ventriculosinus Shunt a Reliable Option?

    Science.gov (United States)

    Oliveira, Matheus Fernandes de; Teixeira, Manoel Jacobsen; Reis, Rodolfo Casimiro; Petitto, Carlo Emanuel; Gomes Pinto, Fernando Campos

    2016-08-01

    Currently, the treatment of hydrocephalus is mainly carried out through a ventriculoperitoneal shunt (VPS) insertion. However, in some cases, there may be surgical revisions and requirement of an alternative distal site for shunting. There are several described distal sites, and secondary options after VPS include ventriculopleural and ventriculoatrial shunt, which have technical difficulties and harmful complications. In this preliminary report we describe our initial experience with retrograde ventriculosinus shunt (RVSS) after failed VPS. In 3 consecutive cases we applied RVSS to treat hydrocephalus in shunt-dependent patients who had previously undergone VPS revision and in which peritoneal space was full of adhesions and fibrosis. RVSS was performed as described by Shafei et al., with some modifications to each case. All 3 patients kept the same clinical profile after RVSS, with no perioperative or postoperative complications. However, revision surgery was performed in the first operative day in 1 out of 3 patients, in which the catheter was not positioned in the superior sagittal sinus. We propose that in cases where VPS is not feasible, RVSS may be a safe and applicable second option. Nevertheless, the long-term follow-up of patients and further learning curve must bring stronger evidence. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma

    Science.gov (United States)

    Shen, Christopher C; Salim, Sarwat; Du, Haiming; Netland, Peter A

    2011-01-01

    Purpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 eyes of 39 patients with underlying diagnosis of neovascular glaucoma, divided into two groups: Ahmed Glaucoma Valve (N = 20) and trabeculectomy with mitomycin C (N = 20). Surgical success was defined as 6 mm Hg ≤ intraocular pressure ≤21 mm Hg, with or without the use of glaucoma medications, with no further glaucoma surgery, and light perception or better vision. Early postoperative hypotony was defined as intraocular pressure Ahmed Glaucoma Valve group and 25 months (6–77 months) for the trabeculectomy group. Although the mean number of postoperative intraocular pressure-lowering medications was significantly higher in the trabeculectomy group compared with the Ahmed Glaucoma Valve group at 3 and 6 month time points, there was no statistically significant difference at any other time point. There was no statistically significant difference between both groups in postoperative visual acuity and intraocular pressure. Success was 70% and 65% at 1 year and 60% and 55% at 2 years after Ahmed Glaucoma Valve and trabeculectomy, respectively. Kaplan–Meier survival curve analysis showed no significant difference in success between the two groups (P = 0.815). Hyphema was the most common complication in both groups. Conclusion: We found similar results after trabeculectomy with mitomycin C and Ahmed Glaucoma Valve implantation in eyes with neovascular glaucoma. PMID:21468334

  19. Glaucoma treatment trends: a review.

    Science.gov (United States)

    Conlon, Ronan; Saheb, Hady; Ahmed, Iqbal Ike K

    2017-02-01

    Glaucoma is one of the most common causes of blindness worldwide, and its prevalence is increasing. The aim of the present review is to describe the current medical and surgical treatment trends in the management of open-angle glaucoma. There has been an increase in the availability of glaucoma medications and the use of laser trabeculoplasty over the past decade, with a subsequent decrease in invasive incisional surgery. In addition, a new class of glaucoma procedures, termed microinvasive glaucoma surgery, has emerged, which aims to fill the gap between conservative medical management and more invasive surgery. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  20. Pediatric glaucoma: current perspectives

    Directory of Open Access Journals (Sweden)

    Marchini G

    2014-05-01

    Full Text Available Giorgio Marchini, Marco Toscani, Francesca Chemello Eye Clinic, Department of Neurological and Movement Sciences, University of Verona, Verona, Italy Abstract: “Childhood glaucoma” is a heterogeneous group of severe pediatric conditions often associated with significant visual loss and characterized by elevated intraocular pressure (IOP and optic-disk cupping. Successful IOP control is crucial but challenging and most often achieved surgically, with medical therapy playing a supportive role. There are many classifications of childhood glaucoma, but they can simply be divided into primary, in which a developmental abnormality of the anterior chamber angle only exists, and secondary, in which aqueous outflow is reduced due to independent mechanisms that secondarily impair the function of the filtration angle. The worldwide prevalence of childhood blindness ranges from 0.03% in high-income countries to 0.12% in undeveloped countries. The majority of cases do not have an identified genetic mutation and, where the mutation is known, the genes often account for only a small proportion of cases. Several pathogenetic mechanisms are known to contribute to the development of childhood glaucoma. Whatever the cause, it results in a reduced aqueous outflow at the level of the trabecular meshwork. Age of onset and magnitude of the elevated IOP largely determine the clinical manifestation the high variability of clinical manifestations. Glaucoma from any cause in a neonate and infant is characterized by the classic triad of epiphora, photophobia, and blepharospasm, and could be associated with eye enlargement (buphthalmos and Haab striae. The eye examination, usually performed under general anesthesia, includes: tonometry, anterior-segment examination, gonioscopy, corneal diameter and axial length measurement, dilated fundoscopy with optic-nerve-head evaluation. Medical therapy, considering the high frequency of side effects, is generally used as

  1. Glaucoma: Hot Topics in Pharmacology.

    Science.gov (United States)

    Balendra, Shiama I; Shah, Parth Arvind; Jain, Mishank; Grzybowski, Andrzej; Cordeiro, Maria F

    2017-01-01

    Glaucoma comprises a group of neurodegenerative diseases resulting in retinal ganglion cell death within the optic nerve head. It is projected to affect almost 80 million people worldwide by 2020. The condition's asymptomatic nature translates to over half of glaucoma sufferers being unaware of their condition. By the time of diagnosis, irreversible blindness is likely to have occurred. Prime areas of glaucoma research therefore include identification and optimization of risk factors for the disease, accurate and early diagnostic tools and novel therapeutic methods. The goal of this review was to summarize main areas of latest glaucoma research into risk factors of glaucoma, diagnostic tools and treatments. PubMed was used to search for terms including glaucoma risk factors, glaucoma diagnostics, glaucoma treatment, glaucoma drug delivery and glaucoma IOP. The evidence for risk factors of low CSF pressure, IOP, smoking, vascular risk factors and light toxicity is described. Latest diagnostic and monitoring techniques for glaucoma include SD-OCT, DARC and IOP telemetry. Current and emerging medical and surgical treatments in glaucoma are discussed. Rho kinase inhibitors have the potential to both lower IOP and also provide neuroprotection, several of which are in clinical trials. Several other new medical treatments such as calcium channel blockers and neurotrophic agents also have the capacity to provide neuroprotection. Minimally Invasive Glaucoma Surgery (MIGS) devices provide an improved safety profile compared to traditional trabeculectomy; the latest ab interno and ab externo devices are described. Novel drug delivery methods, including punctual plugs and contact lenses, help overcome the challenges with patient adherence. The ultimate goals are to reduce the individual patient risk factors associated with glaucoma, diagnose the condition early and to find treatments that not only reduce IOP but also reverse neurodegeneration of RGCs. The usage of combinations

  2. Wound Dehiscence and Device Migration after Subconjunctival Bevacizumab Injection with Ahmed Glaucoma Valve Implantation.

    Science.gov (United States)

    Miraftabi, Arezoo; Nilforushan, Naveed

    2016-01-01

    To report a complication pertaining to subconjunctival bevacizumab injection as an adjunct to Ahmed Glaucoma Valve (AGV) implantation. A 54-year-old woman with history of complicated cataract surgery was referred for advanced intractable glaucoma. AGV implantation with adjunctive subconjunctival bevacizumab (1.25 mg) was performed with satisfactory results during the first postoperative week. However, 10 days after surgery, she developed wound dehiscence and tube exposure. The second case was a 33-year-old man with history of congenital glaucoma and uncontrolled IOP who developed AGV exposure and wound dehiscence after surgery. In both cases, for prevention of endophthalmitis and corneal damage by the unstable tube, the shunt was removed and the conjunctiva was re-sutured. The potential adverse effect of subconjunctival bevacizumab injection on wound healing should be considered in AGV surgery.

  3. Ventriculoperitoneal shunt blockage by hydatid cyst

    Directory of Open Access Journals (Sweden)

    Abrar A Wani

    2013-01-01

    Full Text Available Ventriculoperitoneal (VP shunt is one of the commonest procedures done in neurosurgical practice throughout the world. One of the commonest problems after putting the VP shunt is the shunt obstruction, which can be due to varied causes. Shunt obstruction secondary to the parasitic infections is rarely seen. We are presenting a 15-year-old child, a case of operated cerebral hydatid cyst with hydrocephalus. She presented with shunt malfunction after 1 year of surgical excision of the hydatid cyst. Revision of the VP shunt was done and peroperatively, it was found that the shunt tubing was obstructed due to small hydatid cysts. This is the first reported case of VP shunt obstruction by hydatid cyst.

  4. Glaucoma Monitoring in a Clinical Setting Glaucoma Progression Analysis vs Nonparametric Progression Analysis in the Groningen Longitudinal Glaucoma Study

    NARCIS (Netherlands)

    Wesselink, Christiaan; Heeg, Govert P.; Jansonius, Nomdo M.

    Objective: To compare prospectively 2 perimetric progression detection algorithms for glaucoma, the Early Manifest Glaucoma Trial algorithm (glaucoma progression analysis [GPA]) and a nonparametric algorithm applied to the mean deviation (MD) (nonparametric progression analysis [NPA]). Methods:

  5. 30 CFR 56.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Explosives Electric Blasting § 56.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be kept shunted until...

  6. Challenges in Glaucoma Management

    African Journals Online (AJOL)

    James Standefer

    Glaucoma has been referred to as the 'orphan child' of Vision. 2020 because, though it is the world's leading cause of irreversible blindness, it was not included in its initial list. The main reasons include the inability to restore lost vision, and the need for upgrading the substandard clinical skill levels of many developing ...

  7. Classic papers in glaucoma

    National Research Council Canada - National Science Library

    Ritch, Robert; Caronia, Ronald M

    1999-01-01

    ... Elimination of Intraocular Fluid J.S. Friedenwald The Formation of the Intraocular Fluid. Proctor Award Lecture of the Association for Research in Ophthalmology W.M. Grant, Tonographic Method for Measuring the Facility and Rate of Aqueous Flow in Human Eyes P.A. Chandler , Malignant Glaucoma B. Becker, Decrease in Intraocular Pressure in Man by a Carbo...

  8. Pesquisaje de glaucoma

    Directory of Open Access Journals (Sweden)

    Aldo Sigler Villanueva

    1996-06-01

    Full Text Available Se efectuó un pesquisaje de glaucoma mediante un chequeo masivo al 92,1 % (210 pacientes de la población mayor de 40 años de edad atendida en un consultorio del médico de la familia del municipio Morón. Se encontró que el 9,6 % (20 pacientes presentaban cifras de tensión ocular por encima de los valores normales, así como 3 pacientes que tenían tensión ocular normal, pero con excavaciones de papilas sospechosas y 2 pacientes con antecedentes familiares de glaucoma, los cuales se enviaron a la consulta especializada del Hospital General Provincial Docente de Moron para confirmar o no el diagnóstico.The 92,1 % (210 patients of the population over 40 years treated at a family physician's office in Morón municipality took part in a glaucoma mass screening. It was found that 9,6 % (20 patients showed figures of ocular tension exceeding normal values and that 3 patients had normal ocular tension but presented suspicious excavation of the optic disc. Two patients having glaucoma family history were referred to the specialist at the Provincial General Teaching Hospital of Moron in order to confirm the diagnosis.

  9. open angle glaucoma (poag)?

    African Journals Online (AJOL)

    there is a build up of pressure due to poor outflow of aqueous humor. The outflow obstruction could occur at the trabecular meshwork of the anterior chamber angle or subsequently in the episcleral vein due to raised venous pressure. Such build up of pressure results in glaucoma . Elevated intraocular pressure remains the ...

  10. Glaucomas in Africas

    African Journals Online (AJOL)

    Murdoch

    happens in all secondary glaucomas. There was confusion some years ago in our understanding of the disease, since intraocular pressure was included in the definition of the disease. With the advent of population studies it became apparent that, in some populations, a significant proportion of those with the characteristic ...

  11. Genetics Home Reference: early-onset glaucoma

    Science.gov (United States)

    ... called a syndrome. If glaucoma appears before the age of 5 without other associated abnormalities, it is called primary congenital glaucoma. Other individuals experience early onset of primary open-angle glaucoma, the most ...

  12. Glaucoma: Symptoms, Diagnosis, Treatment and Latest Research

    Science.gov (United States)

    ... of this page please turn Javascript on. Feature: Glaucoma Glaucoma: Symptoms, Diagnosis, Treatment and Latest Research Past Issues / Fall 2009 Table of Contents Symptoms and Diagnosis Glaucoma can develop in one or both eyes. Often ...

  13. Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma

    OpenAIRE

    Netland, Peter; Shen,Chris; Salim,Sarwat; Du,Haiming

    2011-01-01

    Christopher C Shen1, Sarwat Salim2, Haiming Du2, Peter A Netland31Glaucoma Consultants Northwest, Seattle, WA, USA; 2University of Tennessee Health Science Center, Memphis, TN, USA; 3University of Virginia School of Medicine, Charlottesville, VA, USAPurpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 e...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Transjugular Intrahepatic Portosystemic Shunt ( ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  16. Ventriculo-pleural shunt patency study

    International Nuclear Information System (INIS)

    Yeates, K.

    2000-01-01

    Full text: A twenty-four year old male was admitted to hospital complaining of headaches, drowsiness and blurred vision. He suffered from congenital hydrocephalus and had had a ventriculo-peritoneal shunt inserted in infancy. This had undergone many revisions due to persistent peritoneal infections and had recently been replaced with a ventriculo-pleural shunt. The symptoms described suggested shunt blockage and he was referred for a Shunt Patency Study. The current shunt is a HAKIM Programmable Valve Shunt System and the opening pressure was 12cm of CSF (within the normal range). Forty megabecquerels of filtered 99 Tc m O 4 was injected into the pre-chamber of the shunt. Serial images and counts were obtained for twenty-five minutes after the injection. The images showed the tracer flowing from the shunt within the first ten minutes. At twenty minutes almost all of the tracer had drained from the shunt and was present in the right pleural cavity, indicating shunt patency. This study is presented to demonstrate the appearances of a normally functioning, but rarely seen Ventriculo-Pleural CSF Shunt. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Glaucoma in patients with uveitis.

    OpenAIRE

    Panek, W C; Holland, G N; Lee, D A; Christensen, R E

    1990-01-01

    The records of 100 patients (161 eyes) with uveitis were reviewed retrospectively to determine the prevalence of increased intraocular pressure, the forms of uveitis most commonly associated with glaucoma, and the forms that require specific glaucoma therapy. Secondary glaucoma was present in 23 patients (31 eyes): three of 24 patients with acute uveitis (three eyes, 12% of acute uveitis patients) and 20 of 76 patients with chronic uveitis (28 eyes, 26% of chronic uveitis patients). Eighteen ...

  18. P A Mini

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science. P A Mini. Articles written in Bulletin of Materials Science. Volume 36 Issue 4 August 2013 pp 547-551. Composite supercapacitor electrodes made of activated carbon/PEDOT:PSS and activated carbon/doped PEDOT · T S Sonia P A Mini R Nandhini Kalluri Sujith Balakrishnan ...

  19. Cambridge community Optometry Glaucoma Scheme.

    Science.gov (United States)

    Keenan, Jonathan; Shahid, Humma; Bourne, Rupert R; White, Andrew J; Martin, Keith R

    2015-04-01

    With a higher life expectancy, there is an increased demand for hospital glaucoma services in the United Kingdom. The Cambridge community Optometry Glaucoma Scheme (COGS) was initiated in 2010, where new referrals for suspected glaucoma are evaluated by community optometrists with a special interest in glaucoma, with virtual electronic review and validation by a consultant ophthalmologist with special interest in glaucoma. 1733 patients were evaluated by this scheme between 2010 and 2013. Clinical assessment is performed by the optometrist at a remote site. Goldmann applanation tonometry, pachymetry, monoscopic colour optic disc photographs and automated Humphrey visual field testing are performed. A clinical decision is made as to whether a patient has glaucoma or is a suspect, and referred on or discharged as a false positive referral. The clinical findings, optic disc photographs and visual field test results are transmitted electronically for virtual review by a consultant ophthalmologist. The number of false positive referrals from initial referral into the scheme. Of the patients, 46.6% were discharged at assessment and a further 5.7% were discharged following virtual review. Of the patients initially discharged, 2.8% were recalled following virtual review. Following assessment at the hospital, a further 10.5% were discharged after a single visit. The COGS community-based glaucoma screening programme is a safe and effective way of evaluating glaucoma referrals in the community and reducing false-positive referrals for glaucoma into the hospital system. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  20. Clinical outcomes of Ahmed glaucoma valve implantation in pediatric glaucoma.

    Science.gov (United States)

    Pakravan, Mohammad; Esfandiari, Hamed; Yazdani, Shahin; Doozandeh, Azadeh; Dastborhan, Zahra; Gerami, Ebrahim; Kheiri, Bahareh; Pakravan, Parastou; Yaseri, Mehdi; Hassanpour, Kiana

    2018-03-01

    To evaluate the outcomes of Ahmed glaucoma valve implantation in refractory primary congenital glaucoma as well as primary procedure in aphakic glaucoma. In this retrospective study, medical records of patients who underwent Ahmed glaucoma valve implantation for refractory glaucoma and aphakic glaucoma were reviewed. Primary outcome measures were the surgical success defined as intraocular pressure ≤21 mm Hg and decreased ≥20% and no secondary glaucoma surgery. Secondary outcome measures were the number of glaucoma medications, complications, best corrected visual acuity, and intraocular pressure. A total of 62 eyes of refractory primary congenital glaucoma patients (group 1) and 33 eyes of aphakic glaucoma patients (group 2) were included in our study. Mean follow-up was 51 ± 33 months in group 1 and 49 ± 41 months in group 2 (p = 0.82). The cumulative probability of success was 90% in both groups at the first year; however, the success rate was 52.5% in group 1 and 71.5% in group 2 at 5 years' follow-up visit. In group 1, the mean intraocular pressure ± standard deviation was 33.1 ± 8.6 mm Hg at the baseline and decreased to 17.1 ± 5.3 mm Hg at 1 year and 18.5 ± 6.4 at 3 years postoperatively (all p's glaucoma medications was 3 ± 0.7 that decreased to 2 ± 0.8 at final follow-up (p = 0.02). Ahmed glaucoma valve implantation has a moderate success rate in the management of refractory primary congenital glaucoma with an increased chance of tube-related complications. The surgical success rate is higher in case of primary Ahmed glaucoma valve implant for aphakic glaucoma with acceptable safety profile.

  1. Neuroprotective therapies for glaucoma

    Directory of Open Access Journals (Sweden)

    Song W

    2015-03-01

    Full Text Available Wei Song, Ping Huang, Chun Zhang Department of Ophthalmology, Peking University Third Hospital, Beijing, People’s Republic of China Abstract: Glaucoma is the second leading cause for blindness worldwide. It is mainly caused by glaucomatous optic neuropathy (GON characterized by retinal ganglion cell loss, which leads to visual field defect and blindness. Up to now, the main purpose of antiglaucomatous therapies has been to lower intraocular pressure (IOP through surgeries and medications. However, it has been found that progressive GON is still present in some patients with effective IOP decrease. Therefore, risk factors other than IOP elevation, like neurotrophin deprivation and excitotoxicity, contribute to progressive GON. Novel approaches of neuroprotection may be more effective for preserving the function of the optic nerve. Keywords: glaucoma, glaucomatous optic neuropathy, retinal ganglion cells, neuro­protection

  2. Neuroprotection in glaucoma

    Science.gov (United States)

    Vasudevan, Sushil K; Gupta, Viney; Crowston, Jonathan G

    2011-01-01

    Glaucoma is a neurodegenerative disease characterized by loss of retinal ganglion cells and their axons. Recent evidence suggests that intraocular pressure (IOP) is only one of the many risk factors for this disease. Current treatment options for this disease have been limited to the reduction of IOP; however, it is clear now that the disease progression continues in many patients despite effective lowering of IOP. In the search for newer modalities in treating this disease, much data have emerged from experimental research the world over, suggesting various pathological processes involved in this disease and newer possible strategies to treat it. This review article looks into the current understanding of the pathophysiology of glaucoma, the importance of neuroprotection, the various possible pharmacological approaches for neuroprotection and evidence of current available medications. PMID:21150020

  3. Ceratoplastia penetrante e glaucoma Penetrating keratoplasty and glaucoma

    Directory of Open Access Journals (Sweden)

    Márcio Eulálio Barreto Soares

    2007-08-01

    Full Text Available O objetivo deste artigo é discutir os conhecimentos atuais sobre a abordagem clínica e terapêutica da ceratoplastia penetrante e do glaucoma a ela associado.The aim of this article is to make a review about glaucoma associated with penetrating keratoplasty, describing since its incidence and risk factors until the different options for treatment.

  4. Four-dimensional microscope- integrated optical coherence tomography to enhance visualization in glaucoma surgeries.

    Science.gov (United States)

    Pasricha, Neel Dave; Bhullar, Paramjit Kaur; Shieh, Christine; Viehland, Christian; Carrasco-Zevallos, Oscar Mijail; Keller, Brenton; Izatt, Joseph Adam; Toth, Cynthia Ann; Challa, Pratap; Kuo, Anthony Nanlin

    2017-01-01

    We report the first use of swept-source microscope-integrated optical coherence tomography (SS-MIOCT) capable of live four-dimensional (4D) (three-dimensional across time) imaging intraoperatively to directly visualize tube shunt placement and trabeculectomy surgeries in two patients with severe open-angle glaucoma and elevated intraocular pressure (IOP) that was not adequately managed by medical intervention or prior surgery. We performed tube shunt placement and trabeculectomy surgery and used SS-MIOCT to visualize and record surgical steps that benefitted from the enhanced visualization. In the case of tube shunt placement, SS-MIOCT successfully visualized the scleral tunneling, tube shunt positioning in the anterior chamber, and tube shunt suturing. For the trabeculectomy, SS-MIOCT successfully visualized the scleral flap creation, sclerotomy, and iridectomy. Postoperatively, both patients did well, with IOPs decreasing to the target goal. We found the benefit of SS-MIOCT was greatest in surgical steps requiring depth-based assessments. This technology has the potential to improve clinical outcomes.

  5. Glaucoma Medication Preferences among Glaucoma Specialists in Mexico.

    Science.gov (United States)

    Lazcano-Gomez, Gabriel; Alvarez-Ascencio, Daniela; Haro-Zuno, Cindy; Turati-Acosta, Mauricio; Garcia-Huerta, Magdalena; Jimenez-Arroyo, Jesus; Castañeda-Diez, Rafael; Castillejos-Chevez, Armando; Gonzalez-Salinas, Roberto; Dominguez-Dueñas, Francisca; Jimenez-Roman, Jesus

    2017-01-01

    To determine the glaucoma specialists' preferences for the different brands of topical glaucoma medications available in Mexico. A web-based survey was sent to 150 board-certified glaucoma specialists in Mexico, with 14 questions related to brand preferences for all glaucoma medications available in Mexico. Participants were asked to select each glaucoma medication class by brand and to state the factors leading to their choice. Data from 111 (74%) glaucoma specialists were collected. Imot (timolol 0.5%; Sophia, Mexico) was the preferred brand for the beta-blockers (BB) class by 71% (n = 79) of the participants. Azopt (brinzolamide 1%; Alcon Lab, US) was the preferred carbonic anhydrase inhibitor (CAI) by 54% (n = 60) of the glaucoma specialists. Lumigan (bimatoprost 0.01% and 0.03%; Allergan Inc., U.S.) was the first choice for the prostaglandin analogues (PGAs) in 62% (n = 70) of the answers. The most frequently prescribed alpha-agonist (AA) was Agglad (brimonidine 0.2%; Sophia Lab, Mexico) in 44% (n = 49) of the answers. Medication accessibility (31%), cost (29%), and recommended dose (23%) were the three main factors influencing the glaucoma specialists' preferences. Medication cost and accessibility, as well as posology, remain the main factors influencing brand preferences among glaucoma doctors. In our professional opinion, the therapeutic effect must be the leading factor when prescribing topical medications in the daily practice, so that patients receive the best treatment option. This survey provides an understanding of the decision-making process when prescribing glaucoma medications by glaucoma specialists in a Latin American developing country. Ideally, patient treatment should be individualized and aimed to achieve the best results possible for their specific condition. How to cite this article: Lazcano-Gomez G, Alvarez-Ascencio D, Haro-Zuno C, Turati-Acosta M, Garcia-Huerta M, Jimenez-Arroyo J, Castañeda-Diez R, Castillejos-Chevez A, Gonzalez

  6. Pediatric ventriculoperitoneal shunts and their complications: An analysis

    Directory of Open Access Journals (Sweden)

    Nitin Agarwal

    2017-01-01

    Conclusion: With this retrospective review of complications of VP shunts, age at initial shunt insertion and the interval between the age of initial shunt placement and onset of complications were the most important patient-related predictors of shunt failure. The different predominant etiological factors responsible for early and late shunt failure were infective and mechanical complications, respectively.

  7. Glaucoma: a brief update for 2017

    African Journals Online (AJOL)

    glaucoma. Predictions are that glaucoma will affect almost ... Abstract. Glaucoma is a complex condition of the eye and the second leading cause of blindness around the globe. ..... a stinging sensation upon instilling the drops into the eyes, as well as dry eyes .... Dimitriou C, Broadway D. Pathophysiology of glaucoma.

  8. Arguments Against Funding Glaucoma Treatment and Rebuttal

    African Journals Online (AJOL)

    2018-03-01

    Mar 1, 2018 ... for the treatment of glaucoma at no cost to IWG at the point of delivery toward reducing glaucoma,s harmful impact on the .... and logistic reasons. Nigeria doesn .... cataract unlike from glaucoma can be reversed. This does not.

  9. Experience with the Ahmed Glaucoma Valve

    African Journals Online (AJOL)

    Design:Aprospective study of three glaucoma patients who had the Ahmed glaucoma valve implant at the. University of Benin ... Key words: glaucoma, glaucoma valve implant, ... introduced the micro-trephination with a diameter of. 0.6mm in ...

  10. The future of glaucoma surgery

    Directory of Open Access Journals (Sweden)

    Arsham Sheybani

    2015-01-01

    Full Text Available Glaucoma surgery is ripe for innovation. In the last few years, there has been a substantial increase in the number of devices approaching commercialization. While not all that is new is necessarily good, the role of these devices in changing glaucoma surgery is equally important in terms of both success and failure. Trabeculectomy, the most commonly performed incisional filtration surgery for glaucoma, is subjective by nature and certainly has risks. As devices aim to standardize glaucoma surgery, specifically subconjunctival filtration surgery, predictability and in turn safety should theoretically improve. This may allow the glaucoma surgeon to intervene earlier in the disease process, prevent more advanced vision loss and potentially decrease the burden of medications.

  11. A wireless monitoring system for Hydrocephalus shunts.

    Science.gov (United States)

    Narayanaswamy, A; Nourani, M; Tamil, L; Bianco, S

    2015-08-01

    Patients with Hydrocephalus are usually treated by diverting the excess Cerebrospinal Fluid (CSF) to other parts of the body using shunts. More than 40 percentage of shunts implanted fail within the first two years. Obstruction in the shunts is one of the major causes of failure (45 percent) and the detection of obstruction reduces the complexity of the revision surgery. This paper describes a proposed wireless monitoring system for clog detection and flow measurement in shunts. A prototype was built using multiple pressure sensors along the shunt catheters for sensing the location of clog and flow rate. Regular monitoring of flow rates can be used to adjust the valve in the shunt to prevent over drainage or under drainage of CSF. The accuracy of the flow measurement is more than 90 percent.

  12. Arterioportal shunts on dynamic computed tomography

    International Nuclear Information System (INIS)

    Nakayama, T.; Hiyama, Y.; Ohnishi, K.; Tsuchiya, S.; Kohno, K.; Nakajima, Y.; Okuda, K.

    1983-01-01

    Thirty-two patients, 20 with hepatocelluar carcinoma and 12 with liver cirrhosis, were examined by dynamic computed tomography (CT) using intravenous bolus injection of contrast medium and by celiac angiography. Dynamic CT disclosed arterioportal shunting in four cases of hepatocellular carcinoma and in one of cirrhosis. In three of the former, the arterioportal shunt was adjacent to a mass lesion on CT, suggesting tumor invasion into the portal branch. In one with hepatocellular carcinoma, the shunt was remote from the mass. In the case with cirrhosis, there was no mass. In these last two cases, the shunt might have been caused by prior percutaneous needle puncture. In another case of hepatocellular carcinoma, celiac angiography but not CT demonstrated an arterioportal shunt. Thus, dynamic CT was diagnostic in five of six cases of arteriographically demonstrated arterioportal shunts

  13. Return of the mini

    International Nuclear Information System (INIS)

    Ashmore, C.

    2001-01-01

    Partly as a result of the contentious nature of some large hydroelectric schemes, and continuing deregulation on a global scale, the mini hydro systems are enjoying unprecedented growth. This article discusses the reasons for the increase in demand for mini hydro systems, and describes Alstom Power Hydro's new, integrated 'water-to-wire' renewable energy solution which is a modular system which integrates the hydro-turbine, generator and controls to provide a single optimised product called the Mini-Aqua. The Mini-Aqua can be supplied inside a turnkey package including all civil works. The company is also looking to the future with development of its Powerformer technology for smaller-scale, grid-connected applications

  14. The somatic shunt cable model for neurons.

    OpenAIRE

    Durand, D

    1984-01-01

    The derivation of the equations for an electrical model of nerve cells is presented. The model consists of an equivalent cylinder, a lumped somatic impedance, and a variable shunt at the soma. This shunt was introduced to take into account the fast voltage decays observed following the injections of current pulses in some motoneurons and hippocampal granule cells that could not be explained by existing models. The shunt can be interpreted either by penetration damage with the electrode or by ...

  15. Watch Out for Glaucoma | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Watch Out for Glaucoma Past Issues / Spring 2015 Table of Contents A ... used to check eye pressure for signs of glaucoma. Photo courtesy of NEI Glaucoma is a group ...

  16. THE TREATMENT OF OPEN- AND NARROW-ANGLE GLAUCOMA

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... glaucoma will be considered: narrow-angle glaucoma. (acute glaucoma) and ... emotional or a physical crisis. The pain is in the distribu- .... ness, not increased pressure, haunts people suffering from glaucoma'.' The saga of ...

  17. Evaluation of a glaucoma patient

    Science.gov (United States)

    Thomas, Ravi; Loibl, Klaus; Parikh, Rajul

    2011-01-01

    The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma. PMID:21150033

  18. Evaluation of a glaucoma patient

    Directory of Open Access Journals (Sweden)

    Thomas Ravi

    2011-12-01

    Full Text Available The diagnosis of glaucoma is usually made clinically and requires a comprehensive eye examination, including slit lamp, applanation tonometry, gonioscopy and dilated stereoscopic evaluation of the optic disc and retina. Automated perimetry is obtained if glaucoma is suspected. This establishes the presence of functional damage and provides a baseline for follow-up. Imaging techniques are not essential for the diagnosis but may have a role to play in the follow-up. We recommend a comprehensive eye examination for every clinic patient with the objective of detecting all potentially sight-threatening diseases, including glaucoma.

  19. Acupuncture for glaucoma.

    Science.gov (United States)

    Law, Simon K; Li, Tianjing

    2013-05-31

    Glaucoma is a multifactorial optic neuropathy characterized by an acquired loss of retinal ganglion cells at levels beyond normal age-related loss and corresponding atrophy of the optic nerve. Although many treatments are available to manage glaucoma, glaucoma is a chronic condition. Some patients may seek complementary or alternative medicine approaches such as acupuncture to supplement their regular treatment. The underlying plausibility of acupuncture is that disorders related to the flow of Chi (the traditional Chinese concept translated as vital force or energy) can be prevented or treated by stimulating relevant points on the body surface. The objective of this review was to assess the effectiveness and safety of acupuncture in people with glaucoma. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to January 2013), EMBASE (January 1980 to January 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2013), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to January 2013), ZETOC (January 1993 to January 2013), Allied and Complementary Medicine Database (AMED) (January 1985 to January 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov), the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the National Center for Complementary and Alternative Medicine web site (NCCAM) (http://nccam.nih.gov). We did not use any language or date restrictions in the search for trials. We last searched the electronic databases on 8 January 2013 with the exception of NCCAM which was last searched on 14 July 2010. We also handsearched Chinese

  20. Shunt protection for superconducting Maglev magnets

    Energy Technology Data Exchange (ETDEWEB)

    Atherton, D L [Queen' s Univ., Kingston, Ontario (Canada). Dept. of Physics

    1979-09-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated.

  1. Shunt protection for superconducting Maglev magnets

    International Nuclear Information System (INIS)

    Atherton, D.L.

    1979-01-01

    Closely coupled, short-circuited shunt coils are proposed for quench protection of superconducting Maglev magnets which use high resistance, matrix composite conductors. It is shown that, by suitable design, the shunts can reduce induced ac losses and that the changing currents during magnet energization or vehicle lift off and landing can be tolerated. (author)

  2. 30 CFR 57.6401 - Shunting.

    Science.gov (United States)

    2010-07-01

    ... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Electric Blasting-Surface and Underground § 57.6401 Shunting. Except during testing— (a) Electric detonators shall be kept shunted until connected to the blasting line or wired into a blasting round; (b) Wired rounds shall be...

  3. [Secondary glaucoma in Paraguay. Etiology and incidence].

    Science.gov (United States)

    Strohl, A; Pozzi, S; Wattiez, R; Roesen, B; Miño de Kaspar, H; Klauss, V

    1999-06-01

    Glaucoma is the third-most-frequent cause of blindness in the world, with a total of 5.2 million blind people as a result of this disease; 80% live in developing countries. In Paraguay, after cataract it is the second-most-frequent-cause. Early detection of the risk factors and groups can help to avoid progress of this disease. Trauma, cataract and infectious uveitis represent special risks for developing secondary glaucoma, which is a more frequent cause of blindness in third-world countries than in industrialized nations. Until now there has been little data regarding the causes, disease course, and options for therapy. Therefore, secondary glaucoma was examined in Paraguay to obtain information on the situation in Latin America. The aim of the study was to explore the causes of secondary glaucoma for programs concerning prevention and therapy. From November 1996 to February 1997 patients with secondary glaucoma were examined at the University Hospital of Asunción, Paraguay. After the clinical examination the secondary glaucomas were classified. Patients with primary glaucoma were included in the same period of time as well in order to get the rate of secondary glaucoma. Altogether 293 patients were examined: 61 with secondary and 232 with primary glaucoma. The causes of secondary glaucoma in 73 eyes were: 20 (27%) with pseudoexfoliation glaucoma, 19 (26%) with post-traumatic glaucoma, 16 (22%) with neovascular glaucoma, 4 (5%) with lens-related glaucoma, 3 (4%) with glaucoma associated with ocular surgery, 2 (3%) with pigmentary and 2 (3%) with corticoid-induced glaucoma. A ratio of 4:1 primary glaucomas to secondary glaucomas was found. The development of special measures for prevention and early therapy is only possible if the causes of this severe disease are explored. The results of this study represent basic information and could help to introduce of prevention programs.

  4. MR imaging of syringoperitoneal and syringosubarachnoid shunts

    International Nuclear Information System (INIS)

    Hasso, A.N.; Kucharczyk, W.; Mall, J.C.; Colombo, N.; Newton, T.H.; Norman, D.

    1986-01-01

    The authors utilized MR imaging for the evaluation of syringohydromelic shunt procedures in 16 patients. Four characteristic MR imaging findings were seen: ''tethering'' of the spinal cord posteriorly at the site of laminectomy and placement of the shunt tube distortion of the usual elliptical shape of the spinal cord at the site of the shunt, a ''snake-eyes'' appearance of the cord on transverse images which corresponded to the position of the shunt within or next to a collapsed syringohydromelic cavity, and a generous amount of subachnoid space surrounding the collapsed portion of the cavity. Occasionally the shunt could not be visualized on sagittal images but could be seen on transverse images. In the majority of cases, the MR imaging findings were sufficiently characteristic to warrant accurate diagnosis

  5. Scanning laser polarimetry in glaucoma.

    Science.gov (United States)

    Dada, Tanuj; Sharma, Reetika; Angmo, Dewang; Sinha, Gautam; Bhartiya, Shibal; Mishra, Sanjay K; Panda, Anita; Sihota, Ramanjit

    2014-11-01

    Glaucoma is an acquired progressive optic neuropathy which is characterized by changes in the optic nerve head and retinal nerve fiber layer (RNFL). White-on-white perimetry is the gold standard for the diagnosis of glaucoma. However, it can detect defects in the visual field only after the loss of as many as 40% of the ganglion cells. Hence, the measurement of RNFL thickness has come up. Optical coherence tomography and scanning laser polarimetry (SLP) are the techniques that utilize the evaluation of RNFL for the evaluation of glaucoma. SLP provides RNFL thickness measurements based upon the birefringence of the retinal ganglion cell axons. We have reviewed the published literature on the use of SLP in glaucoma. This review elucidates the technological principles, recent developments and the role of SLP in the diagnosis and monitoring of glaucomatous optic neuropathy, in the light of scientific evidence so far.

  6. The medical management of glaucoma

    African Journals Online (AJOL)

    medical and surgical interventions are accessible in the management of glaucoma. This article ..... Cannabinoids. With the recent attention cannabis has been receiving in the management of pain and other cancer related conditions, it.

  7. MiniDraw

    DEFF Research Database (Denmark)

    2018-01-01

    MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010.......MiniDraw is a teaching-oriented 2D graphics direct manipulation framework in Java, inspired by JHotDraw. It is used in the book "Flexible, Reliable Software - using Patterns and Agile Development", by Henrik Bærbak Christensen, published by CRC Press 2010....

  8. The BaBar Mini

    International Nuclear Information System (INIS)

    Brown, David N.

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  9. The BaBar mini

    International Nuclear Information System (INIS)

    Brown, David N.; BaBar Collaboration

    2003-01-01

    BaBar has recently deployed a new event data format referred to as the Mini. The mini uses efficient packing and aggressive noise suppression to represent the average reconstructed BaBar event in under 7 KBytes. The Mini packs detector information into simple transient data objects, which are then aggregated into roughly 10 composite persistent objects per event. The Mini currently uses Objectivity persistence, and it is being ported to use Root persistence. The Mini contains enough information to support detailed detector studies, while remaining small and fast enough to be used directly in physics analysis. Mini output is customizable, allowing users to both truncate unnecessary content or add content, depending on their needs. The Mini has now replaced three older formats as the primary output of BaBar event reconstruction. A reduced form of the Mini will soon replace the physics analysis format as well, giving BaBar a single, flexible event data format covering all its needs

  10. Ventriculoperitoneal shunt complications needing shunt revision in children: A review of 5 years of experience with 48 revisions

    Directory of Open Access Journals (Sweden)

    Rajendra K Ghritlaharey

    2012-01-01

    Full Text Available Background: The aim of this study was to review the management of ventriculoperitoneal (VP shunt complications in children. Patients and Methods: During the last 5 years (January 1, 2006 to December 31, 2010, 236 VP shunt operations were performed in children under 12 years of age; of these, 40 (16.94% developed shunt complications and those who underwent VP shunt revisions were studied. Results: This prospective study included 40 (28 boys and 12 girls children and required 48 shunt revisions. Complications following VP shunts that required shunt revisions were peritoneal catheter/peritoneal end malfunction (18, shunt/shunt tract infections (7, extrusion of peritoneal catheter through anus (5, ventricular catheter malfunction (4, cerebrospinal fluid (CSF leak from abdominal wound (4, shunt system failure (2, ventricular end/shunt displacement (2, CSF pseudocysts peritoneal cavity (2, extrusion of peritoneal catheter from neck, chest, abdominal scar and through umbilicus, one each. Four-fifth of these shunt complications occurred within 6 months of previous surgery. Surgical procedures done during shunt revisions in order of frequency were revision of peritoneal part of shunt (27, 56.25%, revision of entire shunt system (6, 12.5%, extra ventricular drainage and delayed re-shunt (5, 10.41%, shunt removal and delayed re-shunt (5, 10.41%, opposite side shunting (2, 4.16%, cysts excision and revision of peritoneal catheter (2, 4.16% and revision of ventricular catheter (1, 2.08%. The mortalities following VP shunt operations were 44 (18.64% and following shunt revisions were 4 (10%. Conclusions: VP shunt done for hydrocephalus in children is not only prone for complications and need for revision surgery but also associated with considerable mortality.

  11. Mini mental state examination

    DEFF Research Database (Denmark)

    Kørner, Ejnar Alex; Lauritzen, Lise; Wang, August

    2008-01-01

    INTRODUCTION: The Mini Mental State Examination (MMSE) is widely used in Denmark, but often in non-validated versions. In 2000 a cross-sectional workgroup decided on a new common version of the MMSE with a corresponding manual, which is validated for the first time in the present study. MATERIALS...... the severity of dementia disorders. Udgivelsesdato: 2008-Feb-25...

  12. Berkeley mini-collider

    International Nuclear Information System (INIS)

    Schroeder, L.S.

    1984-06-01

    The Berkeley Mini-Collider, a heavy-ion collider being planned to provide uranium-uranium collisions at T/sub cm/ less than or equal to 4 GeV/nucleon, is described. The central physics to be studied at these energies and our early ideas for a collider detector are presented

  13. Central corneal thickness among glaucoma patients attending ...

    African Journals Online (AJOL)

    AAU_CHS

    ocular pressure measurement and is different among different ethnic population and subtypes of glaucoma. The central corneal thickness of different subtypes of glaucoma at Menelik II Hospital ... Intraocular pressure is a key element in the.

  14. Optineurin, a multifunctional protein involved in glaucoma

    Indian Academy of Sciences (India)

    MADHU

    Glaucomas are a heterogeneous group of neurodegenerative eye diseases that ... with normal tension glaucoma (a sub-type of adult onset primary open angle .... identifies variants at CSF1, OPTN and TNFRSF11A as genetic risk factors for.

  15. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  16. Normal-tension glaucoma (Low-tension glaucoma)

    Science.gov (United States)

    Anderson, Douglas R

    2011-01-01

    Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP), with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG), defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like), or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective. PMID:21150042

  17. Normal-tension glaucoma (Low-tension glaucoma

    Directory of Open Access Journals (Sweden)

    Anderson Douglas

    2011-12-01

    Full Text Available Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP, with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG, defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like, or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective.

  18. Provider Education about Glaucoma and Glaucoma Medications during Videotaped Medical Visits

    Directory of Open Access Journals (Sweden)

    Betsy Sleath

    2014-01-01

    Full Text Available Objective. The purpose of this study was to examine how patient, physician, and situational factors are associated with the extent to which providers educate patients about glaucoma and glaucoma medications, and which patient and provider characteristics are associated with whether providers educate patients about glaucoma and glaucoma medications. Methods. Patients with glaucoma who were newly prescribed or on glaucoma medications were recruited and a cross-sectional study was conducted at six ophthalmology clinics. Patients’ visits were videotape recorded and patients were interviewed after visits. Generalized estimating equations were used to analyze the data. Results. Two hundred and seventy-nine patients participated. Providers were significantly more likely to educate patients about glaucoma and glaucoma medications if they were newly prescribed glaucoma medications. Providers were significantly less likely to educate African American patients about glaucoma. Providers were significantly less likely to educate patients of lower health literacy about glaucoma medications. Conclusion. Eye care providers did not always educate patients about glaucoma or glaucoma medications. Practice Implications. Providers should consider educating more patients about what glaucoma is and how it is treated so that glaucoma patients can better understand their disease. Even if a patient has already been educated once, it is important to reinforce what has been taught before.

  19. Angle closure glaucoma in congenital ectropion uvea

    Directory of Open Access Journals (Sweden)

    Grace M. Wang

    2018-06-01

    Full Text Available Purpose: Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations: Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months and required additional surgery (cycloablation or trabeculectomy. Conclusions and importance: Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control. Keywords: Congenital ectropion uvea, Juvenile glaucoma, Angle-closure glaucoma, Glaucoma drainage device

  20. Primary ventriculoperitoneal shunting outcomes: a multicentre clinical audit for shunt infection and its risk factors.

    Science.gov (United States)

    Woo, P Ym; Wong, H T; Pu, J Ks; Wong, W K; Wong, L Yw; Lee, M Wy; Yam, K Y; Lui, W M; Poon, W S

    2016-10-01

    To determine the frequency of primary ventriculoperitoneal shunt infection among patients treated at neurosurgical centres of the Hospital Authority and to identify underlying risk factors. This multicentre historical cohort study included consecutive patients who underwent primary ventriculoperitoneal shunting at a Hospital Authority neurosurgery centre from 1 January 2009 to 31 December 2011. The primary endpoint was shunt infection, defined as: (1) the presence of cerebrospinal fluid or shunt hardware culture that yielded the pathogenic micro-organism with associated compatible symptoms and signs of central nervous system infection or shunt malfunction; or (2) surgical incision site infection requiring shunt reinsertion (even in the absence of positive culture); or (3) intraperitoneal pseudocyst formation (even in the absence of positive culture). Secondary endpoints were shunt malfunction, defined as unsatisfactory cerebrospinal fluid drainage that required shunt reinsertion, and 30-day mortality. A primary ventriculoperitoneal shunt was inserted in 538 patients during the study period. The mean age of patients was 48 years (range, 13-88 years) with a male-to-female ratio of 1:1. Aneurysmal subarachnoid haemorrhage was the most common aetiology (n=169, 31%) followed by intracranial tumour (n=164, 30%), central nervous system infection (n=42, 8%), and traumatic brain injury (n=27, 5%). The mean operating time was 75 (standard deviation, 29) minutes. Shunt reinsertion and infection rates were 16% (n=87) and 7% (n=36), respectively. The most common cause for shunt reinsertion was malfunction followed by shunt infection. Independent predictors for shunt infection were: traumatic brain injury (adjusted odds ratio=6.2; 95% confidence interval, 2.3-16.8), emergency shunting (2.3; 1.0-5.1), and prophylactic vancomycin as the sole antibiotic (3.4; 1.1-11.0). The 30-day all-cause mortality was 6% and none were directly procedure-related. This is the first Hong Kong

  1. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2012-02-01

    OBJECTIVES: Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts. METHODS: A retrospective chart review was conducted on 25 patients treated for IIH between 2001 and 2009. Age, sex, clinical presentation, methods of treatment and failure rates were recorded. RESULTS: Seventy-two per cent were treated initially with LP shunts. Failure rate was 11% in this group. Neuronavigation-assisted VP shunts were used to treat 28%. In this group, the failure rate was 14%. CONCLUSION: Our experience indicates that both LP shunts and VP shuts are effective in controlling all the clinical manifestations of IIH in the immediate postoperative period. Failure rates are slightly higher for VP shunts (14%) than LP shunts (11%). However, revision rates are higher with LP shunts (60%) than with VP shunts (30%).

  2. Congenital portosystemic shunts with and without gastrointestinal bleeding - case series

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ying; Chen, Jun; Chen, Qi; Ji, Min; Pa, Mier; Qiao, Zhongwei [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China); Zhu, Hui [Fudan University Shanghai Cancer Center, Department of Radiology, Shanghai (China); Zheng, Shan [Children' s Hospital of Fudan University, Department of Surgery, Shanghai (China)

    2015-12-15

    The clinical presentation of congenital portosystemic shunt is variable and gastrointestinal bleeding is an uncommon presentation. To describe the imaging features of congenital portosystemic shunt as it presented in 11 children with (n = 6) and without gastrointestinal bleeding (n = 5). We performed a retrospective study on a clinical and imaging dataset of 11 children diagnosed with congenital portosystemic shunt. A total of 11 children with congenital portosystemic shunt were included in this study, 7 with extrahepatic portosystemic shunts and 4 with intrahepatic portosystemic shunts. Six patients with gastrointestinal bleeding had an extrahepatic portosystemic shunt, and the imaging results showed that the shunts originated from the splenomesenteric junction (n = 5) or splenic vein (n = 1) and connected to the internal iliac vein. Among the five cases of congenital portosystemic shunt without gastrointestinal bleeding, one case was an extrahepatic portosystemic shunt and the other four were intrahepatic portosystemic shunts. Most congenital portosystemic shunt patients with gastrointestinal bleeding had a shunt that drained portal blood into the iliac vein via an inferior mesenteric vein. This type of shunt was uncommon, but the concomitant rate of gastrointestinal bleeding with this type of shunt was high. (orig.)

  3. Resonant Electromagnetic Shunt Damping of Flexible Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker

    2016-01-01

    Electromagnetic transducers convert mechanical energy to electrical energy and vice versa. Effective passive vibration damping of flexible structures can therefore be introduced by shunting with an accurately calibrated resonant electrical network thatcontains a capacitor to create the desired...

  4. Endoscopic third ventriculostomy versus ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Patients' medical records, operative notes, and neural tube database records were used to complete a structured questionnaire. The difference in ... likely after 6 months. Keywords: obstructive hydrocephalus; endoscopic third ventriculostomy; ventriculoperitoneal shunt; children; paediatric surgery; neurosurgery; Ethiopia ...

  5. Nonconventional mesocaval prosthetic shunt interposition in ...

    African Journals Online (AJOL)

    years demonstrates shunt patency and normal development ... However, the child's condition and growth ... The child has satisfactory weight and growth gain. (40kg .... infants and toddlers: replacement with decellularized branched pulmonary.

  6. Cell shunt resistance and photovoltaic module performance

    Energy Technology Data Exchange (ETDEWEB)

    McMahon, T.J.; Basso, T.S.; Rummel, S.R. [National Renewable Energy Lab., Golden, CO (United States)

    1996-05-01

    Shunt resistance of cells in photovoltaic modules can affect module power output and could indicate flawed manufacturing processes and reliability problems. The authors describe a two-terminal diagnostic method to directly measure the shunt resistance of individual cells in a series-connected module non-intrusively, without deencapsulation. Peak power efficiency vs. light intensity was measured on a 12-cell, series-connected, single crystalline module having relatively high cell shunt resistances. The module was remeasured with 0.5-, 1-, and 2-ohm resistors attached across each cell to simulate shunt resistances of several emerging technologies. Peak power efficiencies decreased dramatically at lower light levels. Using the PSpice circuit simulator, the authors verified that cell shunt and series resistances can indeed be responsible for the observed peak power efficiency vs. intensity behavior. The authors discuss the effect of basic cell diode parameters, i.e., shunt resistance, series resistance, and recombination losses, on PV module performance as a function of light intensity.

  7. Endoscopic Third Ventriculostomy in Previously Shunted Children

    Directory of Open Access Journals (Sweden)

    Eva Brichtova

    2013-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%. There were two serious complications (4.7%—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically.

  8. Propionibacterium acnes endophthalmitis in Ahmed glaucoma valve.

    Science.gov (United States)

    Gutiérrez-Díaz, E; Montero-Rodríguez, M; Mencía-Gutiérrez, E; Fernández-González, M C; Pérez-Blázquez, E

    2001-01-01

    To report a case of Propionibacterium acnes endophthalmitis in a patient with an Ahmed glaucoma valve. A nine-year-old boy with bilateral congenital glaucoma, with an Ahmed glaucoma valve implanted in the left eye, had recurrent conjunctival dehiscence and endophthalmitis. Vitreous cultures demonstrated the presence of Propionibacterium acnes. This is the first reported case of Propionibacterium acnes endophthalmitis in an Ahmed glaucoma valve and the second one in a glaucoma drainage device. We strongly recommend using a patch graft to prevent and treat tube exposure. Conjunctival grafts may be useful to close the conjunctiva when there is marked scarring to prevent patch exposure and melting or extrusion.

  9. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Cour, Morten la

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling...

  10. Prevalence of glaucoma in a Nigerian hospital | Usifoh | Journal of ...

    African Journals Online (AJOL)

    Primary Open Angle Glaucoma (POAG) was the most common type of glaucoma (91.24%), followed by Normal Tension Glaucoma (NTG) with a prevalence of 3.23%. No significant association was found between age or sex and types of glaucoma. PACG and Juvenile glaucoma remains relatively rare accounting for only ...

  11. Idiopathic intracranial hypertension: lumboperitoneal shunts versus ventriculoperitoneal shunts--case series and literature review.

    LENUS (Irish Health Repository)

    Abubaker, Khalid

    2011-02-01

    Idiopathic intracranial hypertension (IIH) is an uncommon but important cause of headache that can lead to visual loss. This study was undertaken to review our experience in the treatment of IIH by neuronavigation-assisted ventriculoperitoneal (VP) shunts with programmable valves as compared to lumboperitoneal (LP) shunts.

  12. GABA Shunt in Durum Wheat

    Directory of Open Access Journals (Sweden)

    Petronia Carillo

    2018-02-01

    Full Text Available Plant responses to salinity are complex, especially when combined with other stresses, and involve many changes in gene expression and metabolic fluxes. Until now, plant stress studies have been mainly dealt only with a single stress approach. However, plants exposed to multiple stresses at the same time, a combinatorial approach reflecting real-world scenarios, show tailored responses completely different from the response to the individual stresses, due to the stress-related plasticity of plant genome and to specific metabolic modifications. In this view, recently it has been found that γ-aminobutyric acid (GABA but not glycine betaine (GB is accumulated in durum wheat plants under salinity only when it is combined with high nitrate and high light. In these conditions, plants show lower reactive oxygen species levels and higher photosynthetic efficiency than plants under salinity at low light. This is certainly relevant because the most of drought or salinity studies performed on cereal seedlings have been done in growth chambers under controlled culture conditions and artificial lighting set at low light. However, it is very difficult to interpret these data. To unravel the reason of GABA accumulation and its possible mode of action, in this review, all possible roles for GABA shunt under stress are considered, and an additional mechanism of action triggered by salinity and high light suggested.

  13. Clinical findings following Ahmed Glaucoma Valve™ implantation in pediatric glaucoma

    Directory of Open Access Journals (Sweden)

    Amir Pirouzian

    2008-03-01

    Full Text Available Amir Pirouzian1, Joseph L Demer21Department of Ophthalmology, San Diego Children’s Hospital, San Diego, UCSD, San Diego, CA, USA; 2Department of Ophthalmology, Jules Stein Eye Institute, UCLA, Los Angeles, CA, USAPurpose: To describe clinical findings after Ahmed valve drainage implantation in children.Design: All records in one practice were reviewed to identify and describe clinical findings in all children who had undergone Ahmed Glaucoma ValveTM S2 model insertion for uncontrolled primary or secondary glaucoma.Results: A total of 6 patients were identified, ranging in age from 2–15 years. Mean follow-up time averaged from 2–5 years from the time of tube insertion. Three patients exhibited pupillary peaking towards the tube of the valve. All patients required additional surgery or additional medications to control intraocular pressure. Lenticular opacification near the tube site developed in one patient. Gradual tube extrusion was also noted in another two patients.Conclusion: Multiple clinical events follow the Ahmed valve insertion in children. Pupillary irregularity is the most commonly noted event in this series. To avoid or reduce the risk of this complication, additional or modification of surgical procedures could be considered. The mechanism of such occurrence will further be discussed.Keywords: Ahmed Glaucoma Valve, children, pediatric glaucoma

  14. Portal hypertension: A critical appraisal of shunt procedures with emphasis on distal splenorenal shunt in children

    Directory of Open Access Journals (Sweden)

    Nitin Sharma

    2014-01-01

    Full Text Available Background: Extrahepatic portal venous obstruction (EHPVO is the most common cause of pediatric portal hypertension. We analyzed the investigative protocol and results of portosystemic shunts in this group of patients. Materials and Methods: A total of 40 consecutive children aged below 12 years operated with a diagnosis of extra-hepatic portal hypertension formed the study group. Historical data and clinical data were collected. All patients underwent upper gastrointestinal endoscopy, ultrasound Doppler and computed tomographic portogram pre-operatively and post-operatively. Results with respect to shunt patency, hypersplenism and efficacy of different radiological investigations were collected. Results: A total of 40 patients, 28 boys and 12 girls constituted the study group. Lienorenal shunt (LRS was performed in 14 patients; distal splenorenal shunt in 21 patients and side-to-side lienorenal shunt in 4 patients, inferior mesenteric renal shunt was performed in 1 patient. Follow-up ranged from 36 to 70 months. At a minimum follow-up of 3 years, 32 (80% patients were found to have patent shunts. Patent shunts could be visualized in 30/32 patients with computer tomographic portogram (CTP and 28/32 with ultrasound. Varices regressed completely in 26/32 patients and in the rest incomplete regression was seen. Spleen completely regressed in 19/25 patients. Hypersplenism resolved in all patients with patent shunts. Conclusions: Portosystemic shunting in children with EHPVO is a viable option. While long-term cure rates are comparable with sclerotherapy, repeated hospital visits are reduced with one time surgery. Pre-operative and post-operative assessment can be performed with complimentary use of ultrasound, CTP and endoscopy.

  15. Mini Project Programming Exams

    DEFF Research Database (Denmark)

    Nørmark, Kurt; Thomsen, Lone Leth; Torp, Kristian

    2008-01-01

    A number of different types of final programming exams used or considered at the Department of Computer Science, Aalborg University, are identified and analyzed. Based on this analysis, a new type of programming exam is introduced called a Mini Project Programming (MIP) exam. MIP is a group...... years. The MIP exam is a compromise between (1) a long problem-based project exam and (2) a short oral or written programming exam. It is concluded that the strengths of MIP are the high degree of realism in the exam assignment and comprehensiveness relative to the course syllabus. The main challenge...

  16. SQSTM1 Mutations and Glaucoma.

    Directory of Open Access Journals (Sweden)

    Todd E Scheetz

    Full Text Available Glaucoma is the most common cause of irreversible blindness worldwide. One subset of glaucoma, normal tension glaucoma (NTG occurs in the absence of high intraocular pressure. Mutations in two genes, optineurin (OPTN and TANK binding kinase 1 (TBK1, cause familial NTG and have known roles in the catabolic cellular process autophagy. TKB1 encodes a kinase that phosphorylates OPTN, an autophagy receptor, which ultimately activates autophagy. The sequestosome (SQSTM1 gene also encodes an autophagy receptor and also is a target of TBK1 phosphorylation. Consequently, we hypothesized that mutations in SQSTM1 may also cause NTG. We tested this hypothesis by searching for glaucoma-causing mutations in a cohort of NTG patients (n = 308 and matched controls (n = 157 using Sanger sequencing. An additional 1098 population control samples were also analyzed using whole exome sequencing. A total of 17 non-synonymous mutations were detected which were not significantly skewed between cases and controls when analyzed separately, or as a group (p > 0.05. These data suggest that SQSTM1 mutations are not a common cause of NTG.

  17. PSEUDOEXFOLIATION SYNDROME IN ETHIOPIAN GLAUCOMA ...

    African Journals Online (AJOL)

    1999-05-05

    May 5, 1999 ... of a systemic disorder involving an aberrant connective- tissue metabolism ... were included in this study, except those secondary glaucoma cases due to trauma, ... a1(17), found the five and 10 year cumulative probabilities of ...

  18. [Perimetric changes in advanced glaucoma].

    Science.gov (United States)

    Feraru, Crenguta Ioana; Pantalon, Anca

    2011-01-01

    The evaluation of various perimetric aspects in advanced glaucoma stages correlated to morpho-functional changes. MATHERIAL AND METHOD: Retrospective clinical trial over a 10 months time period that included patients with advanced glaucoma stages, for which there have been recorded several computerised visual field tests (central 24-2 strategy, 10-2 strategy with either III or V--Goldman stimulus spot size) along with other morpho-funtional ocular paramaters: VA, lOP optic disk analysis. We included in our study 56 eyes from 45 patients. In most cases 89% it was an open angle glaucoma (either primary or secondary) Mean visual acuity was 0.45 +/- 0.28. Regarding the perimetric deficit 83% had advanced deficit, 9% moderate and 8% early visual changes. As perimetric type of defect we found a majority with general reduction of sensitivity (33 eyes) + ring shape scotoma. In 6 eyes (10.7%) having left only a central isle of vision we performed the central 10-2 strategy with III or V Goldmann stimulus spot size. Statistic analysis showed scarce correlation between the visual acuity and the quantitative perimetric parameters (MD and PSD), and variance analysis found present a multiple correlation parameter p = 0.07 that proves there is no liniary correspondence between the morpho-functional parameters: VA-MD(PSD) and C/D ratio. In advanced glaucoma stages, the perimetric changes are mostly severe. Perimetric evaluation is essential in these stages and needs to be individualised.

  19. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  20. Balanced calibration of resonant shunt circuits for piezoelectric vibration control

    DEFF Research Database (Denmark)

    Høgsberg, Jan; Krenk, Steen

    2012-01-01

    Shunting of piezoelectric transducers and suitable electric circuits constitutes an effective passive approach to resonant vibration damping of structures. Most common design concepts for resonant resistor-inductor (RL) shunt circuits rely on either maximization of the attainable modal damping...

  1. Coupling slots without shunt impedance drop

    International Nuclear Information System (INIS)

    Balleyguier, P.

    1996-01-01

    It is well known that coupling slots between adjacent cells in a π-mode structure reduce shunt impedance per unit length with respect to single cell cavities. To design optimized coupling slots, one has to answer the following question: for a given coupling factor, what shape, dimension, position and number of slots lead to the lowest shunt impedance drop? A numerical study using the 3D code MAFIA has been carried out. The aim was to design the 352 MHz cavities for the high intensity proton accelerator of the TRISPAL project. The result is an unexpected set of four 'petal' slots. Such slots should lead to a quasi-negligible drop in shunt impedance: about -1% on average, for particle velocity from 0.4 c to 0.8 c. (author)

  2. Progress of inflammatory cytokines in glaucoma

    Directory of Open Access Journals (Sweden)

    Ping Hu

    2015-12-01

    Full Text Available Glaucomais a group of diseases characterized by optic nerve damage and visual field defect, and pathological high intraocular pressure is a risk factor for glaucoma. Glaucoma is affected by the interaction of multiple genes and environmental factors, and inflammation may be involved in the pathogenesis of glaucoma. A great deal of studies have confirmed that high expression of connective tissue growth factor(CTGF, tumor necrosis factor-α(TNF-α, interleukins(ILs, nuclear factor-kappa B(NF-κBand various cytokines in the aqueous humor of patients with glaucoma, which have a close correlation with pathogenesis of glaucoma.This article reviews the progress of inflammatory cytokines and their relationship with glaucoma.

  3. Peripheral iridotomy for pigmentary glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lindsley, Kristina

    2016-01-01

    Background Glaucoma is a chronic optic neuropathy characterized by retinal ganglion cell death resulting in damage to the optic nerve head and the retinal nerve fiber layer. Pigment dispersion syndrome is characterized by a structural disturbance in the iris pigment epithelium (the densely pigmented posterior surface of the iris) that leads to dispersion of the pigment and its deposition on various structures within the eye. Pigmentary glaucoma is a specific form of open-angle glaucoma found in patients with pigment dispersion syndrome. Topcial medical therapy is usually the first-line treatment; however, peripheral laser iridotomy has been proposed as an alternate treatment. Peripheral laser iridotomy involves creating an opening in the iris tissue to allow drainage of fluid from the posterior chamber to the anterior chamber and vice versa. Equalizing the pressure within the eye may help to alleviate the friction that leads to pigment dispersion and prevent visual field deterioration. However, the effectiveness of peripheral laser iridotomy in reducing the development or progression of pigmentary glaucoma is unknown. Objectives The objective of this review was to assess the effects of peripheral laser iridotomy compared with other interventions, including medication, trabeculoplasty, and trabeculectomy, or no treatment, for pigment dispersion syndrome and pigmentary glaucoma. Search methods We searched a number of electronic databases including CENTRAL, MEDLINE and EMBASE and clinical trials websites such as (mRCT) and ClinicalTrials.gov. We last searched the electronic databases on 2 November 2015. Selection criteria We included randomized controlled trials (RCTs) that had compared peripheral laser iridotomy versus no treatment or other treatments for pigment dispersion syndrome and pigmentary glaucoma. Data collection and analysis We used standard methodological procedures for systematic reviews. Two review authors independently screened articles for eligibility

  4. Distal splenorenal shunt with partial spleen resection

    Directory of Open Access Journals (Sweden)

    Gajin Predrag

    2007-01-01

    Full Text Available Introduction: Hypersplenism is a common complication of portal hypertension. Cytopenia in hypersplenism is predominantly caused by splenomegaly. Distal splenorenal shunt (Warren with partial spleen resection is an original surgical technique that regulates cytopenia by reduction of the enlarged spleen. Objective. The aim of our study was to present the advantages of distal splenorenal shunt (Warren with partial spleen resection comparing morbidity and mortality in a group of patients treated by distal splenorenal shunt with partial spleen resection with a group of patients treated only by a distal splenorenal shunt. Method. From 1995 to 2003, 41 patients with portal hypertension were surgically treated due to hypersplenism and oesophageal varices. The first group consisted of 20 patients (11 male, mean age 42.3 years who were treated by distal splenorenal shunt with partial spleen resection. The second group consisted of 21 patients (13 male, mean age 49.4 years that were treated by distal splenorenal shunt only. All patients underwent endoscopy and assessment of oesophageal varices. The size of the spleen was evaluated by ultrasound, CT or by scintigraphy. Angiography was performed in all patients. The platelet and white blood cell count and haemoglobin level were registered. Postoperatively, we noted blood transfusion, complications and total hospital stay. Follow-up period was 12 months, with first checkup after one month. Results In the first group, only one patient had splenomegaly postoperatively (5%, while in the second group there were 13 patients with splenomegaly (68%. Before surgery, the mean platelet count in the first group was 51.6±18.3x109/l, to 118.6±25.4x109/l postoperatively. The mean platelet count in the second group was 67.6±22.8x109/l, to 87.8±32.1x109/l postoperatively. Concerning postoperative splenomegaly, statistically significant difference was noted between the first and the second group (p<0.05. Comparing the

  5. Biophysical shunt theory for neuropsychopathology: Part I.

    Science.gov (United States)

    Naisberg, Y; Avnon, M; Weizman, A

    1995-11-01

    We present a new model of the origin of schizophrenia based on biophysical ionic shunts in neuronal (electrical) pathways. Microstructural and molecular evidence is presented for the way in which changes in the neuronal membrane ionic channels may facilitate membrane property rearrangement, leading to a change in the density and composition of the ion channel charge which in turn causes a change in ionic flow orientation and distribution. We suggest that, under abnormal conditions, ionic flow shunts are created which redirect the biophysical collateral neuronal (electrical) pathways, resulting in psychiatric signs and symptoms. This model is complementary to the biological basis of schizophrenia.

  6. Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3T.

    Science.gov (United States)

    Mabray, M C; Uzelac, A; Talbott, J F; Lin, S C; Gean, A D

    2015-05-01

    To report on the MRI compatibility of the Ex-PRESS glaucoma filtration device, a tiny metallic implant placed into the anterior chamber of the eye that is much smaller than traditional glaucoma shunts, and to educate the radiology community regarding its appearance. Seven patients with Ex-PRESS glaucoma filtration devices were identified that had undergone MRI at San Francisco General Hospital/University of California San Francisco Medical Center by searching and cross-referencing the radiology reporting system and the electronic medical record. MRI images were reviewed for artefact interfering with interpretation. Ophthalmology examinations were reviewed for evidence of complications. Eighteen individual MRI examinations were performed during 12 unique MRI events on these 7 patients. 13/18 individual MRI examinations and 7/12 MRI events were performed at 3 T with the others performed at 1.5 T. Mean time from Ex-PRESS implantation to MRI was 17.5 months. Mean time from MRI to first ophthalmology examination was 1.1 months and from MRI to latest ophthalmology examination was 6.6 months. Susceptibility artefact did not interfere with image interpretation and no complications related to MRI were encountered. The Ex-PRESS glaucoma filtration device appears to be safe for MRI at 1.5 and 3 T and does not produce significant susceptibility artefact to affect diagnostic interpretation adversely. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Genetic and Functional Analysis of Congenital Portosystemic Shunts in Dogs

    NARCIS (Netherlands)

    van den Bossche, L.

    2017-01-01

    The general aim of this thesis was to gain further insight into the pathogenesis of congenital portosystemic shunts (CPSS), elucidate mechanisms involved in the pathophysiology of CPSS, and explore predictors of recovery after surgical ligation of the shunt. For intrahepatic portosystemic shunts

  8. The Philadelphia Glaucoma Detection and Treatment Project

    Science.gov (United States)

    Waisbourd, Michael; Pruzan, Noelle L.; Johnson, Deiana; Ugorets, Angela; Crews, John E.; Saaddine, Jinan B.; Henderer, Jeffery D.; Hark, Lisa A.; Katz, L. Jay

    2016-01-01

    Purpose To evaluate the detection rates of glaucoma-related diagnoses and the initial treatments received in the Philadelphia Glaucoma Detection and Treatment Project, a community-based initiative aimed at improving the detection, treatment, and follow-up care of individuals at risk for glaucoma. Design Retrospective analysis. Participants A total of 1649 individuals at risk for glaucoma who were examined and treated in 43 community centers located in underserved communities of Philadelphia. Methods Individuals were enrolled if they were African American aged ≥50 years, were any other adult aged ≥60 years, or had a family history of glaucoma. After attending an informational glaucoma workshop, participants underwent a targeted glaucoma examination including an ocular, medical, and family history; visual acuity testing, intraocular pressure (IOP) measurement, and corneal pachymetry; slit-lamp and optic nerve examination; automated visual field testing; and fundus color photography. If indicated, treatments included selective laser trabeculoplasty (SLT), laser peripheral iridotomy (LPI), or IOP-lowering medications. Follow-up examinations were scheduled at the community sites after 4 to 6 weeks or 4 to 6 months, depending on the clinical scenario. Main Outcome Measures Detection rates of glaucoma-related diagnoses and types of treatments administered. Results Of the 1649 individuals enrolled, 645 (39.1%) received a glaucoma-related diagnosis; 20.0% (n = 330) were identified as open-angle glaucoma (OAG) suspects, 9.2% (n = 151) were identified as having narrow angles (or as a primary angle closure/suspect), and 10.0% (n = 164) were diagnosed with glaucoma, including 9.0% (n = 148) with OAG and 1.0% (n = 16) with angle-closure glaucoma. Overall, 39.0% (n = 64 of 164) of those diagnosed with glaucoma were unaware of their diagnosis. A total of 196 patients (11.9%) received glaucoma-related treatment, including 84 (5.1%) who underwent LPI, 13 (0.8%) who underwent SLT

  9. Angle closure glaucoma in congenital ectropion uvea.

    Science.gov (United States)

    Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L

    2018-06-01

    Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.

  10. Malignant glaucoma after cataract surgery.

    Science.gov (United States)

    Varma, Devesh K; Belovay, Graham W; Tam, Diamond Y; Ahmed, Iqbal Ike K

    2014-11-01

    To report a series of eyes that developed malignant glaucoma after cataract surgery. Private academic practice, Toronto, Ontario, Canada. Retrospective case series. Eyes that developed malignant glaucoma after cataract surgery were treated with medical therapy. This was followed by laser iridozonulohyaloidotomy, anterior chamber reformation and intraocular lens (IOL) pushback, and finally with surgical iridozonulohyaloidovitrectomy if all other measures were unsuccessful. Refraction, intraocular pressure (IOP), gonioscopy, and anterior chamber depth (ACD) by anterior segment optical coherence tomography were analyzed before treatment and after treatment. The study evaluated 20 eyes of 18 female patients aged 44 to 86 years. Preoperatively, the mean refraction was +3.11 diopters (D) ± 2.89 (SD), the mean axial length was 21.30 ± 1.40 mm, and all eyes had narrow or closed angles. Malignant glaucoma was diagnosed a mean of 5.8 ± 7.1 weeks postoperatively. At diagnosis, the mean refraction was -2.15 ± 2.95 D; the mean ACD, 2.49 ± 0.72 mm; and the mean IOP, 28.3 ± 10.8 mm Hg on a mean of 1.3 ± 1.6 medications. Two eyes responded to cycloplegia, 7 to laser iridozonulohyaloidotomy, and 6 to anterior chamber reformation-IOL pushback; 5 eyes required vitrectomy. Posttreatment, the mean refraction was -0.56 ± 1.07 D; the mean ACD, 3.30 ± 0.50 mm; and the mean IOP, 14.4 ± 4.60 mm Hg on a mean of 1.2 ± 1.4 medications. Cycloplegia was discontinued in 17 eyes. Malignant glaucoma can occur after phacoemulsification and presents with myopic surprise, anterior chamber shallowing and, possibly, elevated IOP. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  12. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  13. ARTIFICIAL SHUNTING OF CEREBROSPINAL-FLUID

    NARCIS (Netherlands)

    HOEKSTRA, A

    A compact three-stage shunt valve system (Orbis SigmaTM Valve) which operates as a flow regulator within certain differential pressure values has been clinically evaluated in the treatment of hydrocephalus. Clinical trials were performed in 134 cases, covering 128 patients aged from 1 day to 79

  14. Ventriculoperitoneal shunt infection caused by Bifidobacterium breve.

    Science.gov (United States)

    Suwantarat, Nuntra; Romagnoli, Mark; Wakefield, Teresa; Carroll, Karen C

    2014-08-01

    Bifidobacterium breve is a rare cause of human infections. Previously, bacteremia and meningitis caused by this organism linked to probiotic use have been reported in a neonate. We report the first case of a ventriculoperitoneal shunt infection caused by B. breve in an adult without a history of probiotic use. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Complications of ventriculoperitoneal shunt in hydrocephalic children

    African Journals Online (AJOL)

    These children were treated at the Department of Pediatric Surgery, Dr. Behc¸et Uz Children's Hospital, and at the Department of Neurosurgery, Tepecik Training Hospital. Management of these patients with special emphasis on the literature pertaining to the migration of shunt catheters into the scrotum is reviewed and ...

  16. Update on normal tension glaucoma

    Directory of Open Access Journals (Sweden)

    Jyotiranjan Mallick

    2016-01-01

    Full Text Available Normal tension glaucoma (NTG is labelled when typical glaucomatous disc changes, visual field defects and open anterior chamber angles are associated with intraocular pressure (IOP constantly below 21 mmHg. Chronic low vascular perfusion, Raynaud's phenomenon, migraine, nocturnal systemic hypotension and over-treated systemic hypertension are the main causes of normal tension glaucoma. Goldmann applanation tonometry, gonioscopy, slit lamp biomicroscopy, optical coherence tomography and visual field analysis are the main tools of investigation for the diagnosis of NTG. Management follows the same principles of treatment for other chronic glaucomas: To reduce IOP by a substantial amount, sufficient to prevent disabling visual loss. Treatment is generally aimed to lower IOP by 30% from pre-existing levels to 12-14 mmHg. Betaxolol, brimonidine, prostaglandin analogues, trabeculectomy (in refractory cases, systemic calcium channel blockers (such as nifedipine and 24-hour monitoring of blood pressure are considered in the management of NTG. The present review summarises risk factors, causes, pathogenesis, diagnosis and management of NTG.

  17. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  18. Glaucoma and dry eye disease: the role of preservatives in glaucoma medications

    Directory of Open Access Journals (Sweden)

    Ratna Sitompul

    2011-11-01

    Full Text Available Glaucoma is a common cause of irreversible blindness with increasing prevalence. Some of glaucoma patients will also experience dry eye. Dry eye is the most frequent side effect related to benzalkonium chloride (BAC-containing eye drop  used for glaucoma patients. In addition, glaucoma and dry eyes have shared risk factors that are old age and female. Dry eye among glaucoma patients need to be treated promptly as it produces discomfort, reduces patients’ compliance and   decreases success rate of glaucoma therapy. Dry eye symptoms can be treated by applying preservative-free eye drop, giving combination of preservative containing and preservative-free eye drop to reduce BAC exposure, prescribing artificial tear and conducting surgery to minimize or eliminate the need of topical medication. (Med J Indones 2011; 20:302-5Keywords: benzalkonium chloride, dry eye, glaucoma

  19. Prevalence of open angle glaucoma in accompanying first degree relatives of patients with glaucoma

    Directory of Open Access Journals (Sweden)

    Franciele Vegini

    2008-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine the prevalence of open angle glaucoma in first-degree relatives accompanying POAG patients during routine examination in a reference hospital. METHOD: First-degree relatives of primary open angle glaucoma patients who accompanied their relatives to the glaucoma service of a reference hospital were screened for glaucoma. RESULTS: One-hundred and one first-degree relatives were examined, of which 56.4% had never had their intraocular pressure measured. 10.9% had previously been diagnosed with glaucoma, and 5.9% were newly diagnosed during this study. CONCLUSIONS: The eye examination of first-degree relatives identified a significant percentage of individuals with glaucoma. Despite being first-degree relatives of glaucoma patients, 56.4% of the companions had never had their eye pressure measured, demonstrating a lack of awareness about this disease.

  20. Glaucoma and clinical characteristics in Vietnamese Americans.

    Science.gov (United States)

    Peng, Pai-Huei; Manivanh, Richard; Nguyen, Ngoc; Weinreb, Robert N; Lin, Shan C

    2011-08-01

    To assess the proportions of glaucoma types and clinical characteristics in Vietnamese Americans in a single-center, retrospective study. Medical charts of Vietnamese-American patients who visited a single private practice in Northern California from 1998-2007 were reviewed. The main outcome measures included the distribution and characteristics of glaucoma types, and clinical parameters associated with the presence of various glaucomas. Data from 2247 patients aged 18-98 years were reviewed. Glaucoma was determined for 305 patients (13.6%). Among this group, 54.8% had primary open-angle glaucoma (POAG), 26.9% had primary angle-closure glaucoma (PACG), 13.4% had mixed mechanism glaucoma (MMG), and 4.9% had secondary glaucoma. In the MMG group (41 patients), 27 patients who initially had open angles developed narrow angles and underwent laser peripheral iridotomy (LPI) with a mean follow up of 6.4 years from the time of iridotomy. The other 13 patients had glaucoma progression with open angles after LPI. One POAG patient had neovascular glaucoma due to retinal vein occlusion several years later. Compared to the PACG group, the MMG group had significantly lower baseline intraocular pressure (25.0 vs. 20.2 mmHg, p = 0.007) but with no difference in biometry. POAG is the major type of glaucoma in this clinic-based Vietnamese population. However, Vietnamese appear to have a relatively higher proportion of PACG than Caucasians and those of African descent. It is recommended that gonioscopy be part of the regular eye check-up for adult Vietnamese patients.

  1. Design of low cost glaucoma screening

    NARCIS (Netherlands)

    Niessen, A. G.; Langerhorst, C. T.; Geijssen, H. C.; Greve, E. L.

    1997-01-01

    In 1991 the Netherlands Glaucoma Patient Association organized a glaucoma screening survey. This survey was designed to evaluate the effectiveness of a low cost screening setting. During a screening period of 8 days, 1259 subjects over the age of 49 years were examined by a team of

  2. GLAUCOMA IN PSEUDOEXFOLIATION- CLINICAL PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Balasubramanian M. Manickavelu

    2018-01-01

    Full Text Available BACKGROUND Pseudoexfoliation is one of the common cause of secondary open-angle glaucoma worldwide with a mean progression rate higher than primary open-angle glaucoma. In India, prevalence rate of pseudoexfoliation is around 2% (Hiller et al. In South India, the prevalence rate is 6% in >40 years of age as per Krishnadas et al in 2003. The aim of the study is to study the demographic aspects of pseudoexfoliation, the frequency of glaucoma in patients with pseudoexfoliation syndrome and to assess the treatment response in pseudoexfoliation syndrome. MATERIALS AND METHODS The study was conducted among 96 patients with pseudoexfoliation who attended OP Department of Ophthalmology, Government Tiruvannamalai Medical College and Hospital, Tiruvannamalai, from January 2017 to June 2017. Complete ocular examination with visual acuity, anterior segment examination, intraocular pressure, gonioscopy, fundus examination, central corneal thickness, visual field, ultrasound B scan and ultrasound biomicroscopy was done. RESULTS Incidence of glaucoma is more common in pseudoexfoliation and most of them have open angles. All patients with pseudoexfoliation should undergo complete glaucoma evaluation for early detection. Further ophthalmologist should focus on detection of pseudoexfoliation, since it is related to high risk of operative complication. CONCLUSION Incidence of glaucoma is more in pseudoexfoliation with most common bilateral presentation with open angles with recalcitrant intraocular pressure. Severity of optic nerve damage and with progression of field defects appeared to be more compared to primary open-angle glaucoma. Better response to combination drug therapy and surgical therapy than primary open-angle glaucoma.

  3. Determinants of glaucoma awareness in urban punjab

    International Nuclear Information System (INIS)

    Farooq, S.; Jaffar, S.; Kausar, A.

    2015-01-01

    To assess the awareness about glaucoma and the factors affecting it in urban Punjab population. Study Design: Cross-sectional study. Place and Duration of Study: Study was conducted in March-April 2011 in Rawalpindi District Punjab, Pakistan. Material and Methods: Glaucoma awareness study was conducted on urban population of Rawalpindi, Islamabad, Lahore and Taxila. Individuals belonging to medical profession (doctors, nurses and paramedics etc) were not included. Demographic details and educational status of all participants were documented. A brief structured close-ended study questionnaire was used to collect information about their awareness of risk factors, treatment aspects and complication of glaucoma. Results: There were 729 participants in the study. Majority were females (60.1%) and adults (76.1%). Literacy level of 40.2% was up to matriculate level. The study indicated that the awareness level about glaucoma was low especially about the recognition of high-risk groups and symptoms. Only one-third of respondents i.e. 32.6% had an idea about the symptoms of the disease and 27.4% participants had awareness of glaucoma as a blinding eye disease. Determinants of glaucoma awareness amongst study participants were gender, age, education level and occupation. Conclusion: Awareness of glaucoma was quite low among the urban population in Punjab. There is need of increased public health education to reduce glaucoma associated blindness and its burden on society. (author)

  4. Normal tension glaucoma and Alzheimer disease

    DEFF Research Database (Denmark)

    Bach-Holm, Daniella; Kessing, Svend Vedel; Mogensen, Ulla Brasch

    2012-01-01

    Purpose: To investigate whether normal tension glaucoma (NTG) is associated with increased risk of developing dementia/Alzheimer disease (AD). Methods: A total of 69 patients with NTG were identified in the case note files in the Glaucoma Clinic, University Hospital of Copenhagen (Rigshospitalet...

  5. New pharmacotherapy for the treatment of glaucoma.

    Science.gov (United States)

    Schehlein, Emily M; Novack, Gary; Robin, Alan L

    2017-12-01

    Glaucoma is the second leading cause of blindness in the world and current pharmacotherapies for glaucoma have remained relatively unchanged (with the exception of fixed combinations of previously available medications) since the mid-1990s with the development of prostaglandin analogues. Now, with both new formulations and new classes of medications with novel mechanisms of action, the medical therapy of glaucoma may be heralding a new dawn in medical management. Areas covered: This review outlines new topical therapies for intraocular pressure (IOP) lowering treatment, in addition to new formulations, preservative-free options, and advances in glaucoma medical therapy delivery. We performed a comprehensive search for published studies for glaucoma medical therapy using the electronic database PubMed. A manual search for each therapy or delivery system was also performed. Expert commentary: These advances in glaucoma therapy have the potential to overcome many barriers to glaucoma's medical care, particularly in terms of adherence. However, both time and research are needed to prove the relative efficacy and safety of these new pharmacotherapies and products, helping us decide their role in the treatment of elevated intraocular pressure. We are hopeful that these new developments in therapy may bring more options for glaucoma medical therapy.

  6. Biodegradable microfabricated plug-filters for glaucoma drainage devices.

    Science.gov (United States)

    Maleki, Teimour; Chitnis, Girish; Park, Jun Hyeong; Cantor, Louis B; Ziaie, Babak

    2012-06-01

    We report on the development of a batch fabricated biodegradable truncated-cone-shaped plug filter to overcome the postoperative hypotony in nonvalved glaucoma drainage devices. Plug filters are composed of biodegradable polymers that disappear once wound healing and bleb formation has progressed past the stage where hypotony from overfiltration may cause complications in the human eye. The biodegradable nature of device eliminates the risks associated with permanent valves that may become blocked or influence the aqueous fluid flow rate in the long term. The plug-filter geometry simplifies its integration with commercial shunts. Aqueous humor outflow regulation is achieved by controlling the diameter of a laser-drilled through-hole. The batch compatible fabrication involves a modified SU-8 molding to achieve truncated-cone-shaped pillars, polydimethylsiloxane micromolding, and hot embossing of biodegradable polymers. The developed plug filter is 500 μm long with base and apex plane diameters of 500 and 300 μm, respectively, and incorporates a laser-drilled through-hole with 44-μm effective diameter in the center.

  7. Glaucoma Drainage Device Erosion Following Ptosis Surgery.

    Science.gov (United States)

    Bae, Steven S; Campbell, Robert J

    2017-09-01

    To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Case report. A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.

  8. Monitoring dynamics of aqueous humor in glaucoma

    International Nuclear Information System (INIS)

    Vyborny, P.; Hornova, J.

    1985-01-01

    Aqueous humor dynamics was observed in patients treated for glaucoma. Aqueous flow was measured using the radionuclide method of contact application of 22 NaCl and the detection of gamma radiation with external detectors. The sample of 184 eyes was divided into three groups: open-angle glaucoma with therapy, open-angle glaucoma without therapy and angle-closure glaucoma 47 eyes were used as controls. Changes were observed in 22 Na outflow half-time in dependence on the duration of the disease, therapy, intraocular pressUre and changes in the perimeter. The new technique has been fully proven in practice, is a contribution to the diagnosis of glaucoma and an indicator of the compensation of the disease. (author)

  9. Pathological Predictors of Shunt Stenosis and Hepatic Encephalopathy after Transjugular Intrahepatic Portosystemic Shunt

    Directory of Open Access Journals (Sweden)

    Fuliang He

    2016-01-01

    Full Text Available Background. Transjugular intrahepatic portosystemic shunt (TIPS is an artificial channel from the portal vein to the hepatic vein or vena cava for controlling portal vein hypertension. The major drawbacks of TIPS are shunt stenosis and hepatic encephalopathy (HE; previous studies showed that post-TIPS shunt stenosis and HE might be correlated with the pathological features of the liver tissues. Therefore, we analyzed the pathological predictors for clinical outcome, to determine the risk factors for shunt stenosis and HE after TIPS. Methods. We recruited 361 patients who suffered from portal hypertension symptoms and were treated with TIPS from January 2009 to December 2012. Results. Multivariate logistic regression analysis showed that the risk of shunt stenosis was increased with more severe inflammation in the liver tissue (OR, 2.864; 95% CI: 1.466–5.592; P=0.002, HE comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, or higher MELD score (95% CI, 1.298–1.731; P<0.001. Higher risk of HE was associated with shunt stenosis comorbidity (OR, 6.266; 95% CI, 3.141–12.501; P<0.001, higher stage of the liver fibrosis (OR, 2.431; 95% CI, 1.355–4.359; P=0.003, and higher MELD score (95% CI, 1.711–2.406; P<0.001. Conclusion. The pathological features can predict individual susceptibility to shunt stenosis and HE.

  10. Driving patterns in older adults with glaucoma.

    Science.gov (United States)

    van Landingham, Suzanne W; Hochberg, Chad; Massof, Robert W; Chan, Emilie; Friedman, David S; Ramulu, Pradeep Y

    2013-02-21

    The ability to drive is important for ensuring quality of life for many older adults. Glaucoma is prevalent in this age group and may affect driving. The purpose of this study is to determine if glaucoma and glaucomatous visual field (VF) loss are associated with driving cessation, limitations, and deference to another driver in older adults. Cross-sectional study. Eighty-one glaucoma subjects and 58 glaucoma suspect controls between age 60 and 80 reported if they had ceased driving, limited their driving in various ways, or preferred another to drive. Twenty-three percent of glaucoma subjects and 6.9% of suspects had ceased driving (p = 0.01). Glaucoma subjects also had more driving limitations than suspects (2.0 vs. 1.1, p = 0.007). In multivariable models, driving cessation was more likely for glaucoma subjects as compared to suspects (OR = 4.0; 95% CI = 1.1-14.7; p = 0.03). The odds of driving cessation doubled with each 5 decibel (dB) decrement in the better-eye VF mean deviation (MD) (OR = 2.0; 95% CI = 1.4-2.9; p driving limitations (OR = 4.7; 95% CI = 1.3-16.8; p = 0.02). The likelihood of reporting more limitations increased with the VF loss severity (OR = 1.6 per 5 dB decrement in the better-eye VF MD; 95% CI = 1.1-2.4; p = 0.02). Neither glaucoma nor VF MD was associated with other driver preference (p > 0.1 for both). Glaucoma and glaucomatous VF loss are associated with greater likelihood of driving cessation and greater limitation of driving in the elderly. Further prospective study is merited to assess when and why people with glaucoma change their driving habits, and to determine if their observed self-regulation of driving is adequate to ensure safety.

  11. Scanning the macula for detecting glaucoma

    Directory of Open Access Journals (Sweden)

    Viquar U Begum

    2014-01-01

    Full Text Available Background: With the advent of spectral domain optical coherence tomography (SDOCT, there has been a renewed interest in macular region for detection of glaucoma. However, most macular SDOCT parameters currently are thickness parameters which evaluate thinning of the macular layers but do not quantify the extent of area over which the thinning has occurred. We therefore calculated a new macular parameter, "ganglion cell complex surface abnormality ratio (GCC SAR" that represented the surface area over which the macular thickness was decreased. Purpose: To evaluate the ability of SAR in detecting perimetric and preperimetric glaucoma. Design: Retrospective image analysis. Materials and Methods: 68 eyes with perimetric glaucoma, 62 eyes with preperimetric glaucoma and 165 control eyes underwent GCC imaging with SDOCT. SAR was calculated as the ratio of the abnormal to total area on the GCC significance map. Statistical Analysis: Diagnostic ability of SAR in glaucoma was compared against that of the standard parameters generated by the SDOCT software using area under receiver operating characteristic curves (AUC and sensitivities at fixed specificities. Results: AUC of SAR (0.91 was statistically significantly better than that of GCC average thickness (0.86, P = 0.001 and GCC global loss volume (GLV; 0.88, P = 0.01 in differentiating perimetric glaucoma from control eyes. In differentiating preperimetric glaucoma from control eyes, AUC of SAR (0.72 was comparable to that of GCC average thickness (0.70, P > 0.05 and GLV (0.72, P > 0.05. Sensitivities at specificities of 80% and 95% of SAR were comparable (P > 0.05 for all comparisons to that of GCC average thickness and GLV in diagnosing perimetric and preperimetric glaucoma. Conclusion: GCC SAR had a better ability to diagnose perimetric glaucoma compared to the SDOCT software provided global GCC parameters. However, in diagnosing preperimetric glaucoma, the ability of SAR was similar to that of

  12. The Ahmed Glaucoma Valve in Refractory Glaucoma: Experiences in Southwest Ethiopia.

    Science.gov (United States)

    Gessesse, Girum W

    2015-07-01

    The management of refractory glaucoma is a challenging task for any glaucoma surgeon. This study is aimed to evaluate the efficacy of Ahmed Glaucoma Valve implantation in refractory glaucomas in South-West Ethiopia. A retrospective review was conducted on the charts of consecutive patients treated with Ahmed glaucoma valve implantation at Jimma University Specialized Hospital between August 2012 and August 2014. Success was defined as Intraocular Pressure (IOP) less than 22 mm Hg and greater than 5mm Hg at 6 months, with at least 30% reduction from baseline, without medical therapy (complete success) or either with or without medication (qualified successes). A total of 12 eyes of 11 patients were included. The mean age of patients was 40.7 (SD= 19.0) years; 63.6% of them were males. The main types of glaucoma were pseudoexfoliative (3 eyes), uveitic (2 eyes), chronic angle closure (2 eyes) and Juvenile Open Angle (JOAG) (2 eyes). The mean IOP was reduced from preoperative level (32.75±7.14 mmHg) to (15.75 ±4.35 mmHg) at six postoperative months, (PAhmed glaucoma valve implant appears to be effective and relatively safe for treating complicated glaucomas with success rate comparable with those reported from other studies. Ahmed glaucoma valve, refractory glaucoma, complications, Ethiopia.

  13. Outcomes of Ahmed Glaucoma Valve Revision in Pediatric Glaucoma.

    Science.gov (United States)

    Al-Omairi, Ahmed Mansour; Al Ameri, Aliah H; Al-Shahwan, Sami; Khan, Arif O; Al-Jadaan, Ibrahim; Mousa, Ahmed; Edward, Deepak P

    2017-11-01

    Encapsulation of the Ahmed glaucoma valve (AGV) plate is a common cause for postoperative elevation of intraocular pressure, especially in children. Many reports have described the outcomes of AGV revision in adults. However, the outcomes of AGV revision in children are poorly documented. The aim of this study was to determine the outcomes of AGV revision in children. Retrospective cross-sectional study. A retrospective chart review of patients less than 15 years of age who underwent AGV revision with a minimum postoperative follow-up of 6 months was conducted. Outcome measures included reduction in intraocular pressure from baseline, survival analysis, and reduction in the number of antiglaucoma medications. Postoperative complications were also noted. Complete success was defined as an IOP of 21 mm Hg or less without medications, while qualified success was defined as having an IOP of 21 mm Hg or less with medications. A total of 44 eyes met the inclusion criteria. Primary congenital glaucoma was present in 39 eyes (88.6%), aphakic glaucoma in 4 eyes (9.1%), and Peters anomaly-associated glaucoma in 1 eye (2.3%). The mean number of previous surgeries was 1.4, and the mean age was 6.7 years (range, 1.9-13 years) with a median follow-up of 12 months (range, 6-24 months). The IOP was reduced from a preoperative mean of 30.4 (± 10.3) to 24.9 (± 10.6) mm Hg at 6 months postoperatively. Kaplan-Meier analysis showed that the complete success rate at 1 month was 100% followed by a rapid decline at 6 months to 38.6%, 27.7% at 1 year, and 5.5% at 2 years. Qualified success rate was 100% at 1 month followed by a 6-month and 1-year survival rate of approximately 50% and a 2-year survival rate of approximately 16%. The median survival time was 14 months. No specific risk factors for failure were identified. Visual acuity remained unchanged following revision. The most common complication was recurrence of encapsulation with elevated IOP (15.9%). Other

  14. Efficacy of intravitreal ranibizumab combined with Ahmed glaucoma valve implantation for the treatment of neovascular glaucoma.

    Science.gov (United States)

    Tang, Min; Fu, Yang; Wang, Ying; Zheng, Zhi; Fan, Ying; Sun, Xiaodong; Xu, Xun

    2016-01-09

    Neovascular glaucoma is a refractive glaucoma. Recently, anti-VEGF factors have been used alone or in combination for the treatment of neovascular glaucoma. However, the medium- and long-term efficacy of such drugs remains to be evaluated. This study was to determine the efficacy of intravitreal ranibizumab combined with Ahmed glaucoma valve implantation for the treatment of neovascular glaucoma. In this prospective non-randomized study, 43 neovascular glaucoma patients (43 eyes) were assigned to receive either 0.5 mg intravitreal ranibizumab for three to 14 days before Ahmed glaucoma valve implantation (injection group, n = 21) or Ahmed glaucoma valve implantation alone (control group, n = 22). The patients were followed up for six to 12 months. Differences in surgical success rate, intraocular pressure, best corrected visual acuity, anti-glaucoma medications and postoperative complications were compared between the two groups. Surgical success was defined as IOP > = 6 mm Hg and glaucoma medications, and without severe complications or reoperation. Of the 43 patients, 40 completed the 6-month follow-up and 37 completed the 1-year follow-up. Success rate was 73.7% vs. 71.4% at six months and 72.2% vs. 68.4% at 12 months in the injection group and the control group respectively. No significant difference was noted between the two groups (six months: P = 0.87, 12 months: P = 1.00). There were no significant differences in the two groups with respect to intraocular pressure, best corrected visual acuity, anti-glaucoma medications or postoperative complications at six months or 12 months. Single intravitreal ranibizumab (0.5 mg) before surgery has no significant effect on the medium- or long-term outcomes of neovascular glaucoma treated with Ahmed glaucoma valve implantation. Chinese Clinical Trial Registry ( ChiCTR-OOC-14005709, Trial registration date: 2014-12-01).

  15. Effect of electromagnetic navigated ventriculoperitoneal shunt placement on failure rates.

    Science.gov (United States)

    Jung, Nayoung; Kim, Dongwon

    2013-03-01

    To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters inserted using manual method with anatomical landmark. The relationship between proximal catheter position and shunt revision rate was evaluated using postoperative computed tomography by a 3-point scale. 1) Grade I; optimal position free-floating in cerebrospinal fluid, 2) Grade II; touching choroid or ventricular wall, 3) Grade III; tip within parenchyma. A total of 72 patients were participated, 27 with EM navigated shunts and 45 with standard shunts. Grade I was found in 25 patients from group 1 and 32 patients from group 2. Only 2 patients without use of navigation belonged to grade III. Proximal obstruction took place 7% in grade I, 15% in grade II and 100% in grade III. Shunt revision occurred in 11% of group 1 and 31% of group 2. Compared in terms of proximal catheter position, there was growing trend of revision rate according to increase of grade on each group. Although infection rate was similar between both groups, the result had no statistical meaning (p=0.905, chi-square test). The use of EM navigation in routine shunt surgery can eliminate poor shunt placement resulting in a dramatic reduction in failure rates.

  16. Ventriculosubgaleal shunts for posthemorrhagic hydrocephalus in premature infants.

    Science.gov (United States)

    Willis, Brian K; Kumar, Cherukuri Ravi; Wylen, Esther L; Nanda, Anil

    2005-01-01

    The early management of posthemorrhagic hydrocephalus in premature infants is challenging and controversial. These infants need a temporary cerebrospinal fluid (CSF) diversion procedure until they gain adequate weight, and the blood and protein levels in CSF are reasonably low before permanent shunt can be placed. Various options are available with their associated advantages and disadvantages. Ventriculosubgaleal shunts have been recommended as a more physiologic and less invasive means of achieving this goal. We have performed this procedure in 6 premature infants to evaluate their effectiveness and complications. Six consecutive premature infants with posthemorrhagic hydrocephalus underwent placement of ventriculosubgaleal shunts over a 1-year period of time. We reviewed their clinical and imaging progress to assess the ability of the shunt to control hydrocephalus and the complication rates. In all 6 patients, the ventriculosubgaleal shunt controlled the progression of hydrocephalus as assessed by clinical and imaging parameters. A permanent shunt was avoided in 1 patient (16.6%). However, 4 patients developed shunt infections, 1 involving the ventriculosubgaleal shunt itself, and 3 immediately after conversion to ventriculoperitoneal shunt. The total infection rate of the series was 66.6%. All infections were caused by staphylococcus species. There was only a 1% shunt infection rate in our institution for all nonventriculosubgaleal shunts during the same period of time. Placement of ventriculosubgaleal shunts for interim CSF diversion in neonates with posthemorrhagic hydrocephalus is effective as a temporary method of CSF diversion. However, our experience has shown that it is associated with a unacceptably high CSF infection rate. A potential cause for infection is CSF stasis just beneath the extremely thin skin of the premature infants, promoting colonization by skin flora. CSF sampling before conversion to a permanent shunt and replacement of the proximal

  17. Ex-PRESS glaucoma filter: an MRI compatible metallic orbital foreign body imaged at 1.5 and 3 T

    International Nuclear Information System (INIS)

    Mabray, M.C.; Uzelac, A.; Talbott, J.F.; Lin, S.C.; Gean, A.D.

    2015-01-01

    Aim: To report on the MRI compatibility of the Ex-PRESS glaucoma filtration device, a tiny metallic implant placed into the anterior chamber of the eye that is much smaller than traditional glaucoma shunts, and to educate the radiology community regarding its appearance. Materials and methods: Seven patients with Ex-PRESS glaucoma filtration devices were identified that had undergone MRI at San Francisco General Hospital/University of California San Francisco Medical Center by searching and cross-referencing the radiology reporting system and the electronic medical record. MRI images were reviewed for artefact interfering with interpretation. Ophthalmology examinations were reviewed for evidence of complications. Results: Eighteen individual MRI examinations were performed during 12 unique MRI events on these 7 patients. 13/18 individual MRI examinations and 7/12 MRI events were performed at 3 T with the others performed at 1.5 T. Mean time from Ex-PRESS implantation to MRI was 17.5 months. Mean time from MRI to first ophthalmology examination was 1.1 months and from MRI to latest ophthalmology examination was 6.6 months. Susceptibility artefact did not interfere with image interpretation and no complications related to MRI were encountered. Conclusion: The Ex-PRESS glaucoma filtration device appears to be safe for MRI at 1.5 and 3 T and does not produce significant susceptibility artefact to affect diagnostic interpretation adversely. - Highlights: • The Ex-PRESS glaucoma filtration device is a tiny metallic orbital implant. • It can simulate a metallic orbital foreign body on imaging. • There is little information in the literature about it's MRI safety. • We report 18 MRIs performed on 7 patients including the first at 3 T. • Imaging appears to be safe at 1.5 and 3 T in patients with this device

  18. Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

    Science.gov (United States)

    Greenlee, Emily C; Kwon, Young H

    2008-06-01

    Glaucoma after penetrating keratoplasty is a frequently observed post-operative complication and is a risk factor for graft failure. Penetrating keratoplasty performed for aphakic and pseudophakic bullous keratopathy and inflammatory conditions are more likely to cause postoperative glaucoma compared with keratoconus and Fuchs' endothelial dystrophy. The intraocular pressure elevation may occur immediately after surgery or in the early to late postoperative period. Early postoperative causes of glaucoma include pre-existing glaucoma, retained viscoelastic, hyphema, inflammation, pupillary block, aqueous misdirection, or suprachoroidal hemorrhage. Late causes include pre-existing glaucoma, angle-closure glaucoma, ghost cell glaucoma, suprachoroidal hemorrhage, and steroid-induced glaucoma. Determining the cause of IOP elevation can help guide therapeutic intervention. Treatments for refractory glaucoma include topical anti-glaucoma medications such as beta-adrenergic blockers. Topical carbonic anhydrase inhibitors, miotic agents, adrenergic agonists, and prostaglandin analogs should be used with caution in the post-keratoplasty patient, because of the possibility of corneal decompensation, cystoid macular edema, or persistent inflammation. Various glaucoma surgical treatments have reported success in post-keratoplasty glaucoma. Trabeculectomy with mitomycin C can be successful in controlling IOP without the corneal toxicity noted with 5-fluorouracil. Glaucoma drainage devices have successfully controlled intraocular pressure in postkeratoplasty glaucoma; this is, however, associated with increased risk of graft failure. Placement of the tube through the pars plana may improve graft success compared with implantation within the anterior chamber. In addition, cyclophotocoagulation remains a useful procedure for eyes that have refractory glaucoma despite multiple surgical interventions.

  19. Hydrocephalus shunt technology: 20 years of experience from the Cambridge Shunt Evaluation Laboratory.

    Science.gov (United States)

    Chari, Aswin; Czosnyka, Marek; Richards, Hugh K; Pickard, John D; Czosnyka, Zofia H

    2014-03-01

    The Cambridge Shunt Evaluation Laboratory was established 20 years ago. This paper summarizes the findings of that laboratory for the clinician. Twenty-six models of valves have been tested long-term in the shunt laboratory according to the expanded International Organization for Standardization 7197 standard protocol. The majority of the valves had a nonphysiologically low hydrodynamic resistance (from 1.5 to 3 mm Hg/[ml/min]), which may result in overdrainage related to posture and during nocturnal cerebral vasogenic waves. A long distal catheter increases the resistance of these valves by 100%-200%. Drainage through valves without a siphon-preventing mechanism is very sensitive to body posture, which may result in grossly negative intracranial pressure. Siphon-preventing accessories offer a reasonable resistance to negative outlet pressure; however, accessories with membrane devices may be blocked by raised subcutaneous pressure. In adjustable valves, the settings may be changed by external magnetic fields of intensity above 40 mT (exceptions: ProGAV, Polaris, and Certas). Most of the magnetically adjustable valves produce large distortions on MRI studies. The behavior of a valve revealed during testing is of relevance to the surgeon and may not be adequately described in the manufacturer's product information. The results of shunt testing are helpful in many circumstances, such as the initial choice of shunt and the evaluation of the shunt when its dysfunction is suspected.

  20. Nitrogen heat pipe for cryocooler thermal shunt

    International Nuclear Information System (INIS)

    Prenger F.C.; Hill, D.D.; Daney, D.E.

    1996-01-01

    A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in this temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined

  1. Prophylactic antibiotics in pediatric shunt surgery.

    Science.gov (United States)

    Biyani, N; Grisaru-Soen, G; Steinbok, P; Sgouros, S; Constantini, S

    2006-11-01

    The optimal antibiotic prophylaxis for pediatric shunt-related procedures is not clear. There is much inconsistency among different medical centers. This paper summarizes and analyzes the various prophylactic antibiotic regiments used for shunt-related surgeries at different pediatric neurosurgery centers in the world. A survey questionnaire was distributed through the Pediatric Neurosurgery list-server (an e-mail-based special interest group in pediatric neurosurgery). Forty-five completed questionnaires were received, one per medical center, primarily from pediatric neurosurgeons with the following geographic breakdown: 25 from North America, 13 from Europe, and 7 from Asia and other countries. All centers routinely administered prophylactic antibiotics for shunt-related procedures. The drugs of choice were first-generation cephalosporins (23), second-generation cephalosporins (10), naficillin/oxacillin (4), vancomycin (3), clindamycin (1), amoxicillin (1), and mixed protocols in three centers. The initial drug administration ("first dose") was: in the department before transfer to operating room (5), upon arrival to operating room (11), at induction of anesthesia (13), and at initial skin incision (16). The duration of antibiotic dosage also varied: single dose (13), 24-h administration (26), 48-h administration (2), and longer than 48 h in four centers. Two general tendencies were noted, common to the majority of participating centers. There was a general trend to modify antibiotic treatment protocol in "high-risk" populations. The second common theme noted in more than half of responding centers was the use of long-term antibiotic treatment for externalized devices (such as externalized shunts, external ventricular drains or lumbar drains), usually till the device was in place.

  2. The transjugular intrahepatic portosystemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Owen, A.R.; Stanley, A.J.; Vijayananthan, A.; Moss, J.G.

    2009-01-01

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  3. Train shunting at a workshop area

    DEFF Research Database (Denmark)

    Jacobsen, Per Munk; Pisinger, David

    2011-01-01

    We consider the problem of planning the shunting of train units at a railway workshop area. Before and after the maintenance check, a train unit is parked at a depository track. The problem is to schedule the trains to workshops and depot tracks in order to complete the repairs as soon as possibl....... It turns out, that both GLS and SA find within a few minutes solutions that are a few percent from the best MIP solution found....

  4. The transjugular intrahepatic portosystemic shunt (TIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Owen, A.R. [Department of Radiology, Austin Health, Heidelberg, Melbourne (Australia)], E-mail: andrewowen@doctors.org.uk; Stanley, A.J. [Department of Gastroenterology, Glasgow Royal Infirmary, Glasgow (United Kingdom); Vijayananthan, A. [Department of Biomedical Imaging, University of Malaya, Kuala Lumpur (Malaysia); Moss, J.G. [Department of Radiology, Gartnavel General Hospital, Glasgow (United Kingdom)

    2009-07-15

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  5. Relation between Glaucoma and Sensorineural Hearing Loss

    Directory of Open Access Journals (Sweden)

    A Mollasadeghi

    2008-01-01

    Full Text Available Introduction: Glaucoma is one of the leading causes of blindness throughout the world. Some studies have suggested a relationship between glaucoma and sensorineural hearing loss, while others have found no evidence of an association. We performed a study to determine whether there is a significant difference in hearing of patients with glaucoma and a match control population. Methods: In this cross-sectional study, from February, 2005 till April, 2006, 44 patients with glaucoma were studied. The age range was between 15 to 60 years. After taking a complete medical history, those suffering from presbycusis, history of exposure to ototoxic drugs and substances and history of ear surgery were excluded from the study. All of the patients were cases of open-angle glaucoma, and were surveyed separately for normal-pressure glaucoma. Then complete audiometric tests (PTA, SDS, SRT, Impedance were conducted for all of them, and the results compared with a control group. Results: There was no statistically significant difference between the case group and control group in PTA, SDS, and SRT, except for Normal Tension Glaucoma (NTG. There wasn't any statistically significant difference between two groups with respect to age, gender, and history of diseases. In the NTG group, significant difference was seen only in high frequencies. Conclusion: As mentioned, there was a statistically significant difference between NTG group and control group. It is therefore recommended to conduct complete audiometric tests and histopathologic examinations in this group for early detection of hearing loss and application of rehabilitative measures.

  6. Glaucoma as a Metabolic Optic Neuropathy: Making the Case for Nicotinamide Treatment in Glaucoma.

    Science.gov (United States)

    Williams, Pete A; Harder, Jeffrey M; John, Simon W M

    2017-12-01

    Mitochondrial dysfunction may be an important, if not essential, component of human glaucoma. Using transcriptomics followed by molecular and neurobiological techniques, we have recently demonstrated that mitochondrial dysfunction within retinal ganglion cells is an early feature in the DBA/2J mouse model of inherited glaucoma. Guided by these findings, we discovered that the retinal level of nicotinamide adenine dinucleotide (NAD, a key molecule for mitochondrial health) declines in an age-dependent manner. We hypothesized that this decline in NAD renders retinal ganglion cells susceptible to damage during periods of elevated intraocular pressure. To replete NAD levels in this glaucoma, we administered nicotinamide (the amide of vitamin B3). At the lowest dose tested, nicotinamide robustly protected from glaucoma (~70% of eyes had no detectable glaucomatous neurodegeneration). At this dose, nicotinamide had no influence on intraocular pressure and so its effect was neuroprotective. At the highest dose tested, 93% of eyes had no detectable glaucoma. This represents a ~10-fold decrease in the risk of developing glaucoma. At this dose, intraocular pressure still became elevated but there was a reduction in the degree of elevation showing an additional benefit. Thus, nicotinamide is unexpectedly potent at preventing this glaucoma and is an attractive option for glaucoma therapeutics. Our findings demonstrate the promise for both preventing and treating glaucoma by interventions that bolster metabolism during increasing age and during periods of elevated intraocular pressure. Nicotinamide prevents age-related declines in NAD (a decline that occurs in different genetic contexts and species). NAD precursors are reported to protect from a variety of neurodegenerative conditions. Thus, nicotinamide may provide a much needed neuroprotective treatment against human glaucoma. This manuscript summarizes human data implicating mitochondria in glaucoma, and argues for studies to

  7. Glaucoma evolution in patients with diabetes.

    Science.gov (United States)

    Apreutesei, Nicoleta Anton; Chiselita, D; Motas, O I

    2014-01-01

    Glaucoma and diabetes are two chronic diseases with a long suspected pathogenic relationship. Screening for glaucoma in patients with diabetes. A retrospective study on 92 eyes from 46 patients with primitive open angle glaucoma (POAG) (normal and hypertensive) and intraocular hypertension (OHT) receiving medication and/or surgery associated with diabetes mellitus (DM) (type I, type II, mixed) is presented. Participants were divided into two groups as following: 16 eyes with glaucoma and diabetic retinopathy changes (group 1) and 76 eyes with glaucoma and without diabetic retinopathy changes (group 2). The following parameters were analysed: ocular pressure (Goldmann aplanotonometry), perimeter development (computerized perimetry) and fundus condition (absence, presence or progression of diabetic retinopathy). In patients with glaucoma and diabetic retinopathy (8 patients) we found a mean difference between treated intraocular pressure (IOP) and IOP last untreated control of 4.95 mmHg; a depreciation of the MD by 4.18 dB and an average number of glaucoma medications used of 0.889 +/- 1.054. Predominant changes in proliferative diabetic retinopathy were mild. In patients with glaucoma in the absence of diabetic retinopathy, the average difference between untreated IOP and IOP under treatment at the last check-up was 1.63 mmHg, the MD depreciation was by 0.65 dB and the average number of glaucoma medications used was 0.795 +/- 0.978. No statistically significant differences in terms of initial and final pressure were found. No statistically significant differences in the evolution of changes in perimeter between the two groups were observed. The presence of non-proliferating diabetic retinopathy influenced (only marginally statistically) the glaucomatous disease progression. Large comparative prospective studies are needed for the long-term follow up.

  8. Cranial dural arteriovenous shunts. Part 4. Clinical presentation of the shunts with leptomeningeal venous drainage.

    Science.gov (United States)

    Baltsavias, Gerasimos; Spiessberger, Alex; Hothorn, Torsten; Valavanis, Anton

    2015-04-01

    Cranial dural arteriovenous fistulae have been classified into high- and low-risk lesions mainly based on the pattern of venous drainage. Those with leptomeningeal venous drainage carry a higher risk of an aggressive clinical presentation. Recently, it has been proposed that the clinical presentation should be considered as an additional independent factor determining the clinical course of these lesions. However, dural shunts with leptomeningeal venous drainage include a very wide spectrum of inhomogeneous lesions. In the current study, we correlated the clinical presentation of 107 consecutive patients harboring cranial dural arteriovenous shunts with leptomeningeal venous drainage, with their distinct anatomic and angiographic features categorized into eight groups based on the "DES" (Directness and Exclusivity of leptomeningeal venous drainage and features of venous Strain) concept. We found that among these groups, there are significant angioarchitectural differences, which are reflected by considerable differences in clinical presentation. Leptomeningeal venous drainage of dural sinus shunts that is neither direct nor exclusive and without venous strain manifested only benign symptoms (aggressive presentation 0%). On the other end of the spectrum, the bridging vein shunts with direct and exclusive leptomeningeal venous drainage and venous strain are expected to present aggressive symptoms almost always and most likely with bleeding (aggressive presentation 91.5%). Important aspects of the above correlations are discussed. Therefore, the consideration of leptomeningeal venous drainage alone, for prediction of the clinical presentation of these shunts appears insufficient. Angiographic analysis based on the above concept, offers the possibility to distinguish the higher- from the lower-risk types of leptomeningeal venous drainage. In this context, consideration of the clinical presentation as an additional independent factor for the prediction of their clinical

  9. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  10. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  11. Graphic software ''MiniG'' for the Mini-6

    International Nuclear Information System (INIS)

    Zen, J.

    1984-06-01

    MiniG is a set of subprograms, written and aimed at being used in Fortran for graphic applications in nuclear physics (histograms or point clouds). It includes three representation modes of axis scales (linear, semi-log and squared root), five types of vectors and numerous graphic symbols for spectra representation with or without notation (circle, cross, arrow, triangle, spiral, etc.). It offers also the possibilities of the software ''Plot-10'' of Tektronix, and accept all the types of graphic terminals of SATD connected to Mini-6 [fr

  12. Importance of intraocular pressure in glaucoma

    Science.gov (United States)

    Joos, Karen M.

    1999-06-01

    Glaucoma results in permanent vision loss and affects the peripheral vision initially. It is presented in 22.5 million people worldwide and is the 3rd cause of blindness. Present tonometers are not ideal for intraocular pressure measurements in all eyes. Of concern, PRK and LASIK may result in lower intraocular pressure readings. A challenges now exists for the development of a tonometer which can easily compensate for corneas with many parameters to avoid a future increase in normal-tension glaucoma or glaucoma which is advanced.

  13. Coincidence of retinitis pigmentosa and pseudoexfoliative glaucoma

    Directory of Open Access Journals (Sweden)

    Božić Marija

    2017-01-01

    Full Text Available Introduction. This is an observational case report presenting retinitis pigmentosa associated with pseudoexfoliative glaucoma. Case outline. A 69-year-old man presented with retinitis pigmentosa. On examination, pseudoexfoliative material was detected on anterior segment structures, and intraocular pressure was 26 mmHg in the right and 24 mmHg in the left eye. The patient was commenced on topical antiglaucomatous therapy (timolol + dorzolamide twice daily, latanoprost once in the evening to both eyes. Conclusion. To the best of our knowledge, this is the first reported case of retinitis pigmentosa associated with pseudoexfoliative glaucoma. Although rare, retinitis pigmentosa and glaucoma can occur in the same eye.

  14. High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385

  15. High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.

    Science.gov (United States)

    Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C

    2009-01-01

    To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.

  16. Safety and efficacy of a low-cost glaucoma drainage device for refractory childhood glaucoma.

    Science.gov (United States)

    Kaushik, Sushmita; Kataria, Pankaj; Raj, Srishti; Pandav, Surinder Singh; Ram, Jagat

    2017-12-01

    To evaluate the safety and efficacy of a low-cost glaucoma drainage device (GDD), Aurolab aqueous drainage implant (AADI), similar in design to the Baerveldt glaucoma implant (BGI), in refractory childhood glaucoma. This prospective interventional study was conducted in a tertiary care postgraduate teaching institute. Children aged glaucoma valve implant in children. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    OpenAIRE

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-01-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medicat...

  18. GENDER AND AGE FEATURES OF GLAUCOMA

    Directory of Open Access Journals (Sweden)

    O. V. Makarenk

    2014-02-01

    Full Text Available Today, the definition “glaucoma” combines a number of eye pathologies that lead to irreversible blindness, and therefore is difficult disabling disease. Glaucoma occurs in people of working age, so this problem is not only medical, but also social, because it causes disability in substantial economic costs not only for individual patients, but also for the whole country – patients become unable to work. Gender features of glaucoma are also contradictory. In European literature the basic idea is that men are more likely to suffer from glaucoma than women. Such studies have not been conducted in the Podillya region of Ukraine, that makes impossible to design a reliable global data to estimate the prevalence of glaucoma in different age groups for persons living in Vinnitsa region. Therefore, the aim of the study was a retrospective analysis of medical records of patients in Eye Microsurgery Department of Vinnitsa Regional Clinical Hospital for the period 2008-2012 years for determining the gender and age characteristics. Materials and methods 1418 patients with primary open-angle glaucoma (841 men and 577 women aged 14 to 92 years (mean age 67,12 ± 7,64, which were treated in the Eye Microsurgery Department, took part in the study. For the purpose of the study they were divided into two groups: I – male patients with glaucoma, II – female patients with glaucoma. Each group was divided into 7 subgroups according to the ontogenesis scheme: A – teens, B – youth, C – I adulthood age, D – II adulthood age, E – elderly age, F – senily age and G – centenarians. Thus was allocated 12 research groups. Results The structure of the incidence of glaucoma is 59.31% in men and 40.69% in women. Incidence of glaucoma is highest in the IE group and is 34.98%. The group IIE incidence is lower – 35.32%. In the group D the incidence of glaucoma among men and women was very different (13.89% and 2.89%, respectively. It should also be noted

  19. Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro.

    Science.gov (United States)

    Basati, Sukhraaj; Tangen, Kevin; Hsu, Ying; Lin, Hanna; Frim, David; Linninger, Andreas

    2015-12-01

    Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.

  20. Treatment of refractory chylothorax with externalized pleuroperitoneal shunts in children.

    Science.gov (United States)

    Wolff, A B; Silen, M L; Kokoska, E R; Rodgers, B M

    1999-09-01

    Traditional therapy for refractory chylothorax in the pediatric population has included pleurodesis and thoracic duct ligation. These procedures are associated with high morbidity and questionable success rates. We retrospectively reviewed our experience with 15 patients who underwent treatment for chylous effusions using pleuroperitoneal shunts with exteriorized pump chambers. Mean patient age at time of shunt placement was 2.1 (0.1 to 11.5) years and the most common indication (7 of 15) was refractory chylothorax following surgical correction of congenital heart disease. Mean chylothorax duration before shunt placement was 76 (5 to 810) days and shunts were in place for an average of 104 (12 to 365) days. A total of 19 chylous effusions (pleural or pericardial) were treated with shunts. Nine of 11 right-sided chylothoraces, 5 of 6 left-sided chylothoraces, and 2 of 2 chylopericardia resolved with shunt therapy (84% total). Pleuroperitoneal shunting failed to clear the effusion in 3 children. There were six episodes of shunt malfunction that were repaired and two episodes of infection. Inguinal or umbilical hernia developed in 4 patients. Externalized pleuroperitoneal shunting is a safe, effective, and minimally invasive treatment for children with refractory chylous effusions.

  1. Superconducting fault current-limiter with variable shunt impedance

    Science.gov (United States)

    Llambes, Juan Carlos H; Xiong, Xuming

    2013-11-19

    A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

  2. Over-drainage and persistent shunt-dependency in patients with idiopathic intracranial hypertension treated with shunts and bariatric surgery.

    Science.gov (United States)

    Roth, Jonathan; Constantini, Shlomi; Kesler, Anat

    2015-01-01

    Idiopathic intracranial hypertension (IIH) may lead to visual impairment. Shunt surgery is indicated for refractory IIH-related symptoms that persist despite medical treatment, or those presenting with significant visual decline. Obesity is a risk factor for IIH; a reduction in weight has been shown to improve papilledema. Bariatric surgery (BS) has been suggested for treating IIH associated with morbid obesity. In this study, we describe a high rate of over-drainage (OD) seen in patients following shunts and BS. The study cohort includes 13 patients with IIH that underwent shunt surgery for treatment of the IIH-related symptoms. Six patients underwent BS in addition to the shunt surgery (but not concomitantly). Seven patients had only shunt surgeries with no BS. Data were collected retrospectively. BS effectively led to weight reduction (body mass index decreasing from 43 ± 4 to 28 ± 5). Patients undergoing BS had 1-6 (2.5 ± 1.9) shunt revisions for OD following BS, as opposed to 0-3 (1.4 ± 1.1) revisions prior to BS over similar time spans (statistically insignificant difference), and 0-6 (1.6 ± 2.5) revisions among the non-BS patients over a longer time span (statistically insignificant difference). Two patients in the BS group underwent shunt externalization and closure; however, they proved to be shunt-dependent. Patients with IIH that undergo shunt surgery and BS (not concomitantly) may suffer from OD symptoms, necessitating multiple shunt revisions, and valve upgrades. Despite BS being a valid primary treatment for some patients with IIH, among shunted patients, BS may not lead to resolution of IIH-related symptoms and patients may remain shunt-dependent.

  3. Rate of shunt revision as a function of age in patients with shunted hydrocephalus due to myelomeningocele.

    Science.gov (United States)

    Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G

    2016-11-01

    OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and

  4. Subgaleo-peritoneal shunt: An effective and safer alternative to lumboperitoneal shunt in the management of persistent or recurrent iatrogenic cranial pseudomeningoceles.

    Science.gov (United States)

    Kiran, Narayanam Anantha Sai; Thakar, Sumit; Mohan, Dilip; Aryan, Saritha; Rao, Arun Sadashiva; Hegde, Alangar S

    2013-01-01

    Subgaleo-peritoneal (SP) shunting for pseudomeningoceles (PMCs) is an effective and safer alternative as compared to the lumboperitoneal (LP) shunt. SP shunting was done in six patients (14-60 years) with persistent or recurrent PMCs using the cranial (ventricular part) and the distal parts of a Chhabra shunt connected by a rigid connector without any intervening chamber or valve. Two patients had undergone a prior LP shunt that had failed. One patient was unsuitable for a LP shunt placement. The PMC subsided completely in all the patients following the SP shunt. In one patient, the shunt got displaced and required repositioning. None of the patients developed symptoms of over-drainage or any other complication. All patients were asymptomatic at a mean follow-up of 15 months. These results suggest that SP shunting is a safe, simple, and effective alternative to the traditional LP shunt in the management of persistent or recurrent cranial PMCs.

  5. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  6. Management of exfoliative glaucoma: challenges and solutions.

    Science.gov (United States)

    Holló, Gábor; Katsanos, Andreas; Konstas, Anastasios Gp

    2015-01-01

    Exfoliative glaucoma is the most common type of secondary open-angle glaucoma worldwide. It is characterized by high intraocular pressure (IOP) and worse 24-hour IOP characteristics. In order to minimize progression, treatment of exfoliative glaucoma has to provide a low long-term mean IOP and good 24-hour IOP control. To achieve these goals, fixed-dose combination eye drops, argon and selective laser trabeculoplasty, and various forms of surgery (trabeculectomy, deep sclerectomy, viscocanalostomy, ab interno trabeculotomy, trabecular aspiration, and cataract surgery) all need to be considered during the long-term management of the disease. Since exfoliative glaucoma is a disease of the elderly, and is frequently associated with systemic vascular disease, interdisciplinary consultations are of great clinical importance. These management aspects and the current medical, laser, and surgical results are covered in this review, with a special focus on the needs of the general ophthalmologist.

  7. The interrelation between hypothyroidism and glaucoma

    DEFF Research Database (Denmark)

    Thvilum, Marianne; Hjelm Brandt Kristensen, Frans; Brix, Thomas Heiberg

    2017-01-01

    Data on the association between hypothyroidism and glaucoma are conflicting. We sought to shed light on this by conducting a critical review and meta-analyses. The meta-analyses were conducted in adherence with the widely accepted MOOSE guidelines. Using the Medical Subject Heading (MeSH) terms......: hypothyroidism, myxoedema and glaucoma or intraocular pressure, case-control studies, cohort studies and cross-sectional studies were identified (PubMed) and reviewed. Using meta-analysis, the relative risk (RR) of coexistence of glaucoma and hypothyroidism was calculated. Based on the literature search......, thirteen studies fulfilled the inclusion criteria and could be categorized into two groups based on the exposure. The designs of the studies varied considerably, and there was heterogeneity related to lack of power, weak phenotype classifications and length of follow-up. Eight studies had glaucoma (5757...

  8. Glaucoma detection with damato multifixation campimetry online

    DEFF Research Database (Denmark)

    Olsen, Ane Sophie; Alberti, M.; Serup, L.

    2016-01-01

    to define abnormality, and these were evaluated using the Glaucoma Staging System as gold standard. Receiver operating characteristic (ROC) curves and area under the ROC (AUC) were calculated. Results AUCs from 15 algorithms ranged from 0.79 to 0.90. The most promising algorithm combined results from two...... successive DMCO STANDARD tests. The sensitivity was highly dependent on the severity of glaucoma. Hence, for eyes with mild, moderate, advanced, and severe glaucoma, the DMCO test demonstrated a sensitivity of 11.8, 71.4, 100, and 100%, respectively. The specificity was as high as 98.1%. Median duration per...... eye to complete the DMCO STANDARD test was 86 s for the control group and 125 s in participants with glaucoma. Conclusions DMCO shows promise as a free-of-charge online tool to identify glaucomatous visual field defects in a preselected population. Ongoing studies are evaluating the use of DMCO...

  9. Antihypertensive medication postpones the onset of glaucoma

    DEFF Research Database (Denmark)

    Horwitz, Anna; Klemp, Marc; Jeppesen, Jørgen

    2017-01-01

    The aim was to investigate the impact of antihypertensive medication on the onset of glaucoma. Data from the complete Danish population between 40 and 95 years of age were used in the period from 1996 to 2012, covering >2.6 million individuals. The National Danish Registry of Medicinal Products...... Statistics was used to identify all claimed prescriptions for glaucoma medication and antihypertensive drugs. We first investigated basic correlations in the data and found that patients treated with antihypertensive medication, at any time during the study period, had a significantly higher overall relative...... risk (RR) of glaucoma, even when controlling for age and sex (with a RR of 1.31 and Pglaucoma. To investigate the causal effect of antihypertensive treatment on the onset of treatment for glaucoma, we used...

  10. The role of inflammation in the pathogenesis of glaucoma

    DEFF Research Database (Denmark)

    Vohra, Rupali; Tsai, James C; Kolko, Miriam

    2013-01-01

    Glaucoma is an ocular disorder characterized by the progressive loss of retinal ganglion cells (RGC) and their axons. There are various hypotheses concerning the cause of RGC death. Previously, glaucoma was defined by high intraocular pressure (IOP); during the past decade, however, glaucoma...... specialists have acknowledged that elevated IOP is the most important risk factor for glaucoma, but does not define the disease. Other factors such as genetics, blood flow, and excitotoxicity are suggested as potential causal factors for progressive RGC death observed in glaucoma. We review recent studies...... elucidating a possible role of low-grade inflammation as a causal factor in the pathogenesis of glaucoma....

  11. The use of Ahmed glaucoma valve in the management of pediatric glaucoma.

    Science.gov (United States)

    Balekudaru, Shantha; Vadalkar, Juhie; George, Ronnie; Vijaya, Lingam

    2014-08-01

    To assess the intraocular pressure control (IOP), changes in visual acuity, complications, reoperation rates and risk factors for failure following Ahmed glaucoma valve implantation in pediatric eyes with glaucoma. The medical records of consecutive patients with glaucoma who underwent Ahmed glaucoma valve implantation from January 2000 to December 2009) were retrospectively reviewed. Only one eye of each patient was included. Subgroup analysis was performed in three groups; group 1 included phakic eyes with primary congenital glaucoma, juvenile open-angle glaucoma, or glaucoma associated with ocular anomalies; group 2 included eyes with glaucoma in aphakia or pseudophakia; group 3 included eyes with other diagnoses. A successful outcome was defined as final IOP between 6 mm Hg and 18 mm Hg without loss of light perception or reoperation for glaucoma. A total of 71 eyes in 71 patients: 15 (21%) in group 1, 47 (66%) in group 2, and 9 (13%) in group 3 were included Successful IOP control was achieved in 44 eyes of 44 patients (62%). Cumulative probabilities of success by Kaplan-Meier analysis at 12 and 24 months was 97% and 80% for the entire group, 100% and 82% for group 1, 95% and 86% for group 2, and 90% and 42% for group 3. Reoperation was necessary for 18 patients (25%), either for tube-related complications or for IOP control. The only significant risk factor for failure was the category of diagnosis (P = 0.029). Ahmed glaucoma valve implantation is an option in the management of pediatric glaucoma; however, reoperations for tube related complications or for persistent elevated IOP is frequently needed. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  12. The optic nerve head in glaucoma

    Directory of Open Access Journals (Sweden)

    Rupert RA Bourne

    2006-09-01

    Full Text Available ll types of glaucoma involve glaucomatous optic neuropathy. The key to detection and management of glaucoma is understanding how to examine the optic nerve head (ONH. This pictorial glossary addresses the following issues: how to examine the ONH; normal characteristics of the ONH; characteristics of a glaucomatous ONH; how to tell if the glaucomatous optic neuropathy is getting worse;‘pitfalls and pearls’.

  13. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    OpenAIRE

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical...

  14. The role of matricellular proteins in glaucoma.

    LENUS (Irish Health Repository)

    Wallace, Deborah M

    2014-07-01

    Glaucoma is an optic neuropathy affecting approximately 60million people worldwide and is the second most common cause of irreversible blindness. Elevated intraocular pressure (IOP) is the main risk factor for developing glaucoma and is caused by impaired aqueous humor drainage through the trabecular meshwork (TM) and Schlemm\\'s canal (SC). In primary open angle glaucoma (POAG), this elevation in IOP in turn leads to deformation at the optic nerve head (ONH) specifically at the lamina cribrosa (LC) region where there is also a deposition of extracellular matrix (ECM) molecules such as collagen and fibronectin. Matricellular proteins are non-structural secreted glycoproteins that help cells communicate with their surrounding ECM. This family of proteins includes connective tissue growth factor (CTGF), also known as CCN2, thrombospondins (TSPs), secreted protein acidic and rich in cysteine (SPARC), periostin, osteonectin, and Tenascin-C and -X and other ECM proteins. All members appear to play a role in fibrosis and increased ECM deposition. Most are widely expressed in tissues particularly in the TM and ONH and deficiency of TSP1 and SPARC have been shown to lower IOP in mouse models of glaucoma through enhanced outflow facility. The role of these proteins in glaucoma is emerging as some have an association with the pathophysiology of the TM and LC regions and might therefore be potential targets for therapeutic intervention in glaucoma.

  15. Macular thickness after glaucoma filtration surgery.

    Science.gov (United States)

    Sesar, Antonio; Cavar, Ivan; Sesar, Anita Pusić; Geber, Mia Zorić; Sesar, Irena; Laus, Katia Novak; Vatavuk, Zoran; Mandić, Zdravko

    2013-09-01

    The aim of present study was to analyze early postoperative changes in the macular area using optical coherence tomography (OCT) after uncomplicated glaucoma filtration surgery. This prospective study included 32 patients (34 eyes) with open-angle glaucoma, which underwent trabeculectomy with or without use of mitomycin C. Exclusion criteria were macular edema, uveitis, age-related macular degeneration, blurred optical media, secondary glaucoma and angle-closure glaucoma. All standard clinical examinations were made before surgery, at the 2nd day, 1 week and 1 month after surgery. Tomography of the macula was performed during every examination using Cirrus HD OCT for the analysis of central subfield thickness. Results show that thickening of the macula was slightly higher 1 week and 1 month after operation in comparison with baseline end 2nd day postoperativelly. There was no significant difference in the change of macular thickness in patients who have used topical prostaglandins compared with those who have used other topical medications. Also, there was no difference in macular changes between patients treated with or without mitomycin C. In conclusion, we found a slight subclinical increase in macular thickness after uncomplicated trabeculectomy, for which we considered that was the result in reduction of intraocular pressure after glaucoma surgery. Macular thickening after glaucoma filtering surgery could be a physiological reaction to the stress of the retina caused by a sudden reduction of intraocular pressure and it is the consequence of altered relationship between capillary pressure and interstitial fluid pressure.

  16. "Mini", "Midi" and the Student.

    Science.gov (United States)

    Edwards, Perry; Broadwell, Bruce

    Mini- and midi-computers have been introduced into the computer science program at Sierra College to afford students more direct contact with computers. The college's administration combined with the Science and Business departments to share the expense and utilization of the program. The National Cash Register Century 100 and the Data General…

  17. Glaucoma screening during regular optician visits : can the population at risk of developing glaucoma be reached?

    NARCIS (Netherlands)

    Stoutenbeek, R.; Jansonius, N. M.

    2006-01-01

    Aim: To determine the percentage of the population at risk of developing glaucoma, which can potentially be reached by conducting glaucoma screening during regular optician visits. Methods: 1200 inhabitants aged > 40 years were randomly selected from Dutch community population databases. A

  18. The glaucoma research foundation patient survey: patient understanding of glaucoma and its treatment.

    Science.gov (United States)

    Herndon, Leon W; Brunner, Thomas M; Rollins, Jane Neff

    2006-01-01

    Determine patients' understanding of glaucoma and its treatment, their sources of information about glaucoma, their preferences for treatment, their experience with medication side effects, and their reasons for changing eye doctors. Prospective, nonrandomized patient survey study. A questionnaire was developed and sent to the 22,000 subscribers of the Gleams newsletter who have glaucoma. Questionnaires were returned by 4310 glaucoma patients. Most respondents received glaucoma information from their eye doctor. Only 28% of respondents reported having changed eye doctors for reasons related to their glaucoma. Of those who had, 60% cited poor communication as the reason. When queried about specific side effects associated with their medication, over 85% of responding patients were never or rarely bothered by headaches and eyelid darkening. Most respondents (67% and 55%, respectively) were rarely or never disturbed by red eye or burning and stinging. Most respondents understood the importance of intraocular pressure (IOP) lowering in glaucoma, and of those patients who expressed a preference, 92% reported that they would prefer the medication that lowers IOP the most, even if it caused red eye for a few weeks, over a medication that caused no red eye but did not get IOP as low. Patients who subscribe to Gleams and responded to the survey rely most on their doctors for information about glaucoma and its treatment. Most understand the importance of maintaining low IOP to decrease the risk of vision loss, and most will tolerate temporary ocular side effects to achieve low IOP.

  19. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-01-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts. (author)

  1. Evaluation of Blalock-Taussig shunts using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Okajima, Yoshitomo; Tashima, Kazuyuki; Terai, Masaru; Niwa, Koichirou.

    1988-10-01

    Four patients aged 3 to 18 months (mean 13 months) with a total of five Blalock-Taussig shunts (BT shunts; two were original BT shunts and three were modified BT shunts using GOLASKI grafts) underwent evaluation by ECG-gated magnetic resonance imaging. There were two cases with pulmonary atresia with intact ventricular septum, one with double outlet right ventricle with pulmonary stenosis and one with tetralogy of Fallot with pulmonary atresia who underwent bilateral BT shunts. At the time of study, an auscultory shunt murmur was audible in all patients. The magnetic resonance images were obtained with a Picker International Vista MR with a superconducting magnet operating at 0.5 Tesla. A spin echo sequence (echo time 40 msec) was used. All patients were placed within a 30 cm head coil radio antenna and sedated with chloral hydrate or diazepam. Four of 5 shunts were imaged on both coronal sections and sagittal sections during enddiastole. And there was no signal within the grafts. When the velocity of blood flow is beyond the cutoff velocity, the signal intensity of flowing blood is near background level. So we judged these grafts were patient. Our results showed that MRI was a very useful noninvasive method for evaluation of BT shunts.

  2. Splenophrenic portosystemic shunt in dogs with and without portal ...

    African Journals Online (AJOL)

    The possible existence of the same pattern of porto-caval connection in dogs having a single congenital portosystemic shunt (CPSS) and in dogs having multiple acquired portosystemic shunt (MAPSS) secondary to portal hypertension (PH) was evaluated. Retrospective evaluation of all CT examinations of patients having ...

  3. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2011-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  4. Spontaneous knot; a rare cause of ventriculoperitoneal shunt blockage.

    LENUS (Irish Health Repository)

    Mohammed, Wail

    2012-02-01

    A 14-year old X linked congenital hydrocephalus presented with unexplained headaches and vomiting. He had external ventricular drain and intracranial pressure monitoring (ICP). Subsequently, he underwent exploration and removal of previously inserted ventriculoperitoneal (VP) shunts. On retrieval of peritoneal catheters a double knot was noted between his two distal catheters. This case illustrates a rare cause of ventriculoperitoneal shunt malfunction.

  5. Clopidogrel in infants with systemic-to-pulmonary-artery shunts

    DEFF Research Database (Denmark)

    Wessel, David L; Berger, Felix; Li, Jennifer S

    2013-01-01

    BACKGROUND: Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity relate......-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.)....

  6. Migration of the peritoneal catheter of a ventriculoperitoneal shunt ...

    African Journals Online (AJOL)

    Ventricular shunt is a well-established modality in the management of hydrocephalus. However, it can be associated with numerous complications and disastrous consequences. The reported incidence of intra-abdominal complications in infants and children after ventriculoperitoneal (VP) shunt procedures is about 24% ...

  7. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    The increasing importance of Power Quality problems has been responsible for several improvements in Active Power Filter (APF) typologies in the last decade. The increased cost and switching losses make a pure shunt APF economically impractical for high power applications. In higher power levels shunt Hybrid Active ...

  8. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Zhang, Jun; Ouyang, Ziwei; Duffy, Maeve C.

    2014-01-01

    with a magnetic shunt by means of the stored magnetic energy in the primary and secondary sides of the transformer using the magnetomotive force (MMF) variation method, as well as the stored energy in the shunt based on the reluctance model. The detailed calculation method is described. Both the FEA simulation...

  9. An unusual case of intrahepatic portosystemic venous shunt

    African Journals Online (AJOL)

    vena cava (IVC) (most common). Intrahepatic portosystemic venous shunts are rare vascular anomalies that may be detected in asymptomatic patients, given the recent advances in radiological imaging techniques. Accurate shunt evaluation and classification can be performed with ultrasound and multi-detector computed.

  10. The effect of an Ahmed glaucoma valve implant on corneal endothelial cell density in children with glaucoma secondary to uveitis.

    Science.gov (United States)

    Kalinina Ayuso, Viera; Scheerlinck, Laura M; de Boer, Joke H

    2013-03-01

    To assess the effect of Ahmed glaucoma valve implants on corneal endothelial cell density (ECD) in children with uveitic glaucoma. Cross-sectional study. setting: Institutional. patientpopulation: Eighty eyes from 42 patients diagnosed with uveitis before the age of 16. Twenty-eight eyes had an Ahmed glaucoma valve implant because of secondary glaucoma. Fifty-two eyes without an implant served as controls. intervention orobservationprocedure(s): Corneal ECD was examined cross-sectionally using a noncontact specular microscope. Univariate and multivariate generalized estimating equations analyses with correction for paired eyes were performed. mainoutcomemeasure(s): Correlation of ECD with the presence of an Ahmed glaucoma valve implant and with the time following implantation. ECD was significantly lower in the Ahmed glaucoma valve group than in controls (2359 and 3088 cells/mm(2), respectively; P Ahmed glaucoma valve implantation. Presence of an Ahmed glaucoma valve implant, previous intraocular surgery, age, duration of uveitis, and history of corneal touch by the implant tube were all significantly associated with decreased ECD. Following a multivariate analysis, presence of an Ahmed glaucoma valve implant (B = -340; adjusted P Ahmed glaucoma valve implantation was highly correlated with decreased ECD (B = -558, P Ahmed glaucoma valve implants in children with uveitic glaucoma are independently associated with decreased ECD, and this effect is associated with the time interval following Ahmed glaucoma valve implantation. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Calibration of piezoelectric RL shunts with explicit residual mode correction

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2017-01-01

    Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained by an exte......Piezoelectric RL (resistive-inductive) shunts are passive resonant devices used for damping of dominant vibration modes of a flexible structure and their efficiency relies on the precise calibration of the shunt components. In the present paper improved calibration accuracy is attained...... by an extension of the local piezoelectric transducer displacement by two additional terms, representing the flexibility and inertia contributions from the residual vibration modes not directly addressed by the shunt damping. This results in an augmented dynamic model for the targeted resonant vibration mode...

  12. Shunt attachment and method for interfacing current collection systems

    Science.gov (United States)

    Denney, Paul E.; Iyer, Natraj C.; Hannan, III, William F.

    1992-01-01

    A composite brush to shunt attachment wherein a volatile component of a composite but mostly metallic brush, used for current collection purposes, does not upon welding or brazing, adversely affect the formation of the interfacial bond with a conductive shunt which carries the current from the zone of the brush. The brush to shunt attachment for a brush material of copper-graphite composite and a shunt of copper, or substituting silver for copper as an alternative, is made through a hot isostatic pressing (HIP). The HIP process includes applying high pressure and temperature simultaneously at the brush to shunt interface, after it has been isolated or canned in a metal casing in which the air adjacent to the interface has been evacuated and the interfacial area has been sealed before the application of pressure and temperature.

  13. Vibration damping with negative capacitance shunts: theory and experiment

    International Nuclear Information System (INIS)

    De Marneffe, B; Preumont, A

    2008-01-01

    This paper analyzes in detail the enhancement of piezoelectric stack transducers by means of the well known 'negative' capacitive shunting. The stability is thoroughly studied: starting from the electrical admittance curve of the transducer, a method is introduced that quantifies the stability margins of the shunted structure. Two different implementations (series vs parallel) are investigated, and the lack of robustness of the parallel one is demonstrated. Next, this technique is experimentally applied on a truss structure. Its performances are compared with those of passive shunt circuits and with those of an active control law, the so-called Integral Force Feedback or IFF. As expected, the damping introduced by the negative capacitance shunt is larger than the damping obtained with the passive shunts; it remains, however, one order of magnitude smaller than that obtained with the IFF

  14. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    International Nuclear Information System (INIS)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene; Monti, Cinzia; Bellomi, Massimo

    2002-01-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  15. Percutaneous peritoneovenous shunt positioning: technique and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Orsi, Franco; Grasso, Rosario Francesco; Bonomo, Guido; Marinucci, Irene [Division of Radiology, European Institute of Oncology, Milan (Italy); Monti, Cinzia [Institute of Radiology, University of Milan (Italy); Bellomi, Massimo [Division of Radiology, European Institute of Oncology, Milan (Italy); Institute of Radiology, University of Milan (Italy)

    2002-05-01

    Nine peritoneovenous shunts were positioned by percutaneous technique in seven patients with advanced malignancy causing severe refractory ascites, and in two patients with hepatic cirrhosis (one with hepatocarcinoma). In all patients the shunts were percutaneously placed through the subclavian vein in the angiographic suite under digital fluoroscopic guide. No complications directly related to the procedure occurred. The shunt was successfully positioned in all patients in 60 min average time. No patient showed symptoms related to pulmonary overload or to disseminated intravascular coagulation. All patients had a significant improvement of the objective symptoms related to ascites such as respiratory symptoms, dyspepsia, and functional impairment to evacuation describing an improvement of their quality of life. Maximum shunt patency was 273 days. Percutaneous placement of peritoneovenous shunt is a safe, fast, and inexpensive procedure, extremely useful in resolution of refractory ascites, reducing symptoms, and allowing effective palliation, with a great improvement in quality of life. (orig.)

  16. Experimental Contact Lens to Prevent Glaucoma-Induced Blindness

    Science.gov (United States)

    ... An Experimental Contact Lens to Prevent Glaucoma-Induced Blindness By Sharon Reynolds Posted January 23, 2014 An ... group of conditions that can result in irreversible blindness. This vision loss can be reduced if glaucoma ...

  17. Ocular hemodynamics and glaucoma: the role of mathematical modeling.

    Science.gov (United States)

    Harris, Alon; Guidoboni, Giovanna; Arciero, Julia C; Amireskandari, Annahita; Tobe, Leslie A; Siesky, Brent A

    2013-01-01

    To discuss the role of mathematical modeling in studying ocular hemodynamics, with a focus on glaucoma. We reviewed recent literature on glaucoma, ocular blood flow, autoregulation, the optic nerve head, and the use of mathematical modeling in ocular circulation. Many studies suggest that alterations in ocular hemodynamics play a significant role in the development, progression, and incidence of glaucoma. Although there is currently a limited number of studies involving mathematical modeling of ocular blood flow, regulation, and diseases (such as glaucoma), preliminary modeling work shows the potential of mathematical models to elucidate the mechanisms that contribute most significantly to glaucoma progression. Mathematical modeling is a useful tool when used synergistically with clinical and laboratory data in the study of ocular blood flow and glaucoma. The development of models to investigate the relationship between ocular hemodynamic alterations and glaucoma progression will provide a unique and useful method for studying the pathophysiology of glaucoma.

  18. awareness and knowledge of glaucoma among adult patients

    African Journals Online (AJOL)

    PATIENTS AT THE EYE CLINIC OF A TEACHING HOSPITAL. G. NKUM1, S. LARTEY2, ... Background: Primary open angle glaucoma (POAG) is an irreversible .... If patients are aware of the risk factors and presentation of glaucoma, there will ...

  19. Potential applications of optical coherence tomography angiography in glaucoma.

    Science.gov (United States)

    Dastiridou, Anna; Chopra, Vikas

    2018-05-01

    Optical coherence tomography angiography (OCTA) is a novel, noninvasive imaging modality that allows assessment of the retinal and choroidal vasculature. The scope of this review is to summarize recent studies using OCTA in glaucoma and highlight potential applications of this new technology in the field of glaucoma. OCTA studies have shown that retinal vascular changes may not develop solely as a result of advanced glaucoma damage. OCTA-derived measurements have provided evidence for lower retinal vascular densities at the optic nerve head, peripapillary and macula in preperimetric-glaucoma and early-glaucoma, as well as, in more advanced glaucoma, in comparison to with normal eyes. OCTA is a novel imaging modality that has already started to expand our knowledge base regarding the role of ocular blood flow in glaucoma. Future studies will better elucidate the role of OCTA-derived measurements in clinical practice, research, and clinical trials in glaucoma.

  20. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  1. Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study

    Science.gov (United States)

    2017-05-02

    Glaucoma; Glaucoma Suspect; Diabetic Retinopathy; Ocular Hypertension; Cataract; Branch Retinal Vein Occlusion; Branch Retinal Arterial Occlusion; Central Retinal Vein Occlusion; Central Retinal Artery Occlusion; Epi-retinal Membrane; Macular Degeneration; Drusen; Loss of Vision

  2. Glaucoma

    Medline Plus

    Full Text Available ... the special health problems and requirements of the blind.” News & Events Events Calendar NEI Press Releases News ... Videos Home Age-Related Macular Degeneration Amblyopia Animations Blindness Cataract Convergence Insufficiency Diabetic Eye Disease Dilated Eye ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research ... on Social Media Information in Spanish (Información en español) Website, Social Media Policies and Other Important Links ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... Clinical Studies Publications Catalog Photos ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... from NEI Grantees Spokesperson bios Statistics and Data ... to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov ...

  6. Glaucoma

    Science.gov (United States)

    ... un ser querido Ojos sanos Ojos sanos Problemas de visión comunes Enfermedades y condiciones de los ojos relacionadas con la edad Consejos simples ... Encontrando un Oculista Asistencia Financiera para el Cuidado de los Ojos Cómo ... in vision loss and blindness. It is one of the main causes of blindness in the United States. However, with ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us Visiting the NIH Campus Mission Statement As part ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ... This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to the NEI Contact Us ... government’s National Institutes of Health (NIH), the National Eye Institute’s mission is to “conduct and support research, ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications (301)496-5248 Health Information Frequently asked questions ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov NIH…Turning Discovery Into Health ®

  16. Glaucoma

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  20. Glaucoma

    Medline Plus

    Full Text Available Skip to main content Search Search: Search Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments ...

  1. Glaucoma

    Medline Plus

    Full Text Available ... part of the federal government’s National Institutes of Health (NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to ...

  2. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is ...

  6. Glaucoma

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home >> NEI YouTube Videos >> ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... visual function, preservation of sight, and the special health problems and requirements of the blind.” News & Events Events ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. ... of Health and Human Services | The National Institutes of Health | ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... on Social Media | Search A-Z | en español | Text size S M L About NEI NEI Research Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of ... Social Media Information in Spanish (Información en español) Website, Social Media Policies and Other Important Links NEI ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  15. Glaucoma

    Medline Plus

    Full Text Available ... Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ... maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... Office of the Scientific Director Office of the Clinical Director Laboratories, Sections and Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... 496-5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural ...

  19. Glaucoma

    Medline Plus

    Full Text Available ... is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding ... NEI Office of Communications (301)496-5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos ...

  20. Glaucoma

    Medline Plus

    Full Text Available ... to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  1. Glaucoma

    Medline Plus

    Full Text Available ... Amaurosis Low Vision Refractive Errors Retinopathy of Prematurity Science Spanish ... Site Map NEI on Social Media Information in Spanish (Información en español) Website, ...

  2. Glaucoma

    Medline Plus

    Full Text Available ... and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision ... DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  3. Glaucoma

    Medline Plus

    Full Text Available ... Accomplishments Budget and Congress About the NEI Director History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ...

  4. Glaucoma

    Medline Plus

    Full Text Available ... of visual function, preservation of sight, and the special health problems and requirements of the blind.” News & ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  5. Glaucoma

    Medline Plus

    Full Text Available ... 5248 Health Information Frequently asked questions Clinical Studies Publications Catalog Photos and Images Spanish Language Information Grants ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  6. Glaucoma

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  7. Glaucoma

    Medline Plus

    Full Text Available ... Search Search the NEI Website search NEI on Social Media | Search A-Z | en español | Text size S M ... Contact Us A-Z Site Map NEI on Social Media Information in Spanish (Información en español) Website, Social ...

  8. Glaucoma

    Medline Plus

    Full Text Available ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ... website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this ...

  9. Glaucoma

    Medline Plus

    Full Text Available ... for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media ... Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  10. Glaucoma

    Medline Plus

    Full Text Available ... blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and requirements of the blind.” ... DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  11. Glaucoma

    Medline Plus

    Full Text Available ... blind.” News & Events Events Calendar NEI Press Releases News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin. ...

  12. Glaucoma

    Medline Plus

    Full Text Available ... Campus Mission Statement As part of the federal government’s National Institutes of Health (NIH), the National Eye ... Publications Catalog Photos and Images Spanish Language Information Grants and Funding Extramural Research Division of Extramural Science ...

  13. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit ...

  14. Glaucoma

    Medline Plus

    Full Text Available ... Program Vision and Aging Program African American Program Training and Jobs Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for current job openings visit HHS USAJobs Home » NEI YouTube Videos » ...

  15. Glaucoma

    Science.gov (United States)

    ... NEI Intranet (Employees Only) *PDF files require the free Adobe® Reader® software for viewing. This website is maintained by the NEI Office of Science Communications, Public Liaison, and Education. Technical questions about this website can be addressed ...

  16. Glaucoma

    Medline Plus

    Full Text Available ... Press Releases News from NEI Grantees Spokesperson bios Statistics and Data Resources for the media Pressroom Contacts Dustin Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations ...

  17. Glaucoma

    Medline Plus

    Full Text Available ... History of the NEI NEI 50th Anniversary NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  18. Glaucoma

    Medline Plus

    Full Text Available ... blind.” News & Events Events Calendar ... Hays - Chief, Science Communication dustin.hays@nih.gov Kathryn DeMott, Media Relations Kathryn.DeMott@nih.gov NEI Office of Communications ( ...

  19. Parylene MEMS patency sensor for assessment of hydrocephalus shunt obstruction.

    Science.gov (United States)

    Kim, Brian J; Jin, Willa; Baldwin, Alexander; Yu, Lawrence; Christian, Eisha; Krieger, Mark D; McComb, J Gordon; Meng, Ellis

    2016-10-01

    Neurosurgical ventricular shunts inserted to treat hydrocephalus experience a cumulative failure rate of 80 % over 12 years; obstruction is responsible for most failures with a majority occurring at the proximal catheter. Current diagnosis of shunt malfunction is imprecise and involves neuroimaging studies and shunt tapping, an invasive measurement of intracranial pressure and shunt patency. These patients often present emergently and a delay in care has dire consequences. A microelectromechanical systems (MEMS) patency sensor was developed to enable direct and quantitative tracking of shunt patency in order to detect proximal shunt occlusion prior to the development of clinical symptoms thereby avoiding delays in treatment. The sensor was fabricated on a flexible polymer substrate to eventually allow integration into a shunt. In this study, the sensor was packaged for use with external ventricular drainage systems for clinical validation. Insights into the transduction mechanism of the sensor were obtained. The impact of electrode size, clinically relevant temperatures and flows, and hydrogen peroxide (H2O2) plasma sterilization on sensor function were evaluated. Sensor performance in the presence of static and dynamic obstruction was demonstrated using 3 different models of obstruction. Electrode size was found to have a minimal effect on sensor performance and increased temperature and flow resulted in a slight decrease in the baseline impedance due to an increase in ionic mobility. However, sensor response did not vary within clinically relevant temperature and flow ranges. H2O2 plasma sterilization also had no effect on sensor performance. This low power and simple format sensor was developed with the intention of future integration into shunts for wireless monitoring of shunt state and more importantly, a more accurate and timely diagnosis of shunt failure.

  20. Determinants of glaucoma awareness and knowledge in urban Chennai

    Directory of Open Access Journals (Sweden)

    Sathyamangalam Ramesh

    2009-01-01

    Full Text Available Aim: To assess the awareness and knowledge levels about glaucoma and its determinants in an urban population of Chennai in south India. Materials and Methods: Chennai glaucoma study (CGS was a population based prevalence study to estimate the prevalence of glaucoma in a rural and urban south Indian population. A total of 3850 subjects aged 40 years or above participated in the urban arm of CGS. A systematic random sample of 1926 (50.0% subjects completed a questionnaire that assesses their awareness and knowledge level of glaucoma. Respondents "having heard of glaucoma" even before they were contacted/recruited for the study were defined as "aware" and respondents having some understanding of the eye disease were defined as "knowledgeable". Results: Overall 13.5% were aware of glaucoma, the age-gender adjusted rate for awareness was 13.3% (95% CI: 11.57 to 15.03. Two clinicians graded knowledge on glaucoma, based on the subject′s knowledge of risk factors, definitions and treatment aspects of glaucoma. Overall 8.7% had some knowledge about glaucoma. Among those who had knowledge 0.5% had good knowledge about glaucoma, 4% had fair knowledge and 4.2% had poor knowledge. We observed a very good agreement between the clinicians in grading knowledge (k =0.92. Determinants of glaucoma awareness and knowledge were higher levels of education, females, age, religion and family history of glaucoma. Conclusion: Awareness and knowledge about glaucoma was very low among the urban population of Chennai. We have found that younger subjects and men were less aware of glaucoma. Subjects with lower levels of education were less aware and knew less about glaucoma than their counterparts. The study findings stress the need for health education for effective prevention of blindness due to glaucoma.

  1. Demographic features of subjects with congenital glaucoma

    Science.gov (United States)

    Tamçelik, Nevbahar; Atalay, Eray; Bolukbasi, Selim; Çapar, Olgu; Ozkok, Ahmet

    2014-01-01

    Context: Congenital glaucoma is a potentially blinding ocular disease of the childhood. Identification of the possible associated risk factors and may be helpful for prevention or early detection of this public health problem. Aims: To demonstrate the demographic features of congenital glaucoma subjects. Setting and Design: The charts of congenital glaucoma patients referred to Tamcelik Glaucoma Center were retrospectively reviewed through the dates of 2000 and 2013. Materials and Methods: Analyzed data included diagnosis, age at first presentation, symptoms at first presentation, laterality of the disease, sex, presence of consanguinity, family history of congenital glaucoma, maturity of the fetus at delivery, and maternal age at conception. Statistical Analysis Used: Statistical Package for Social Sciences (SPSS) version 19.0 by IBM (SPSS Inc, Chicago, Illinois, USA) was used to compare the mean of continuous variables with Student's t-test and analysis of variance (ANOVA) and χ2 test was used to test differences in proportions of categorical variables. Results: The data of 600 eyes of 311 patients were analyzed. The distribution of primary and secondary congenital glaucoma among the patients were 63.3% (n = 197) and 36.7% (n = 114), respectively. Of the 311 patients, 57.2% (n = 178) were male and 42.8% (n = 133) were female. The overall frequency of bilateral disease was 92.3% (n = 287). Overall rate of consanguinity and positive family history was 45.3% (n = 141) and 21.2% (n = 66), respectively. Conclusions: Bilateral disease in this study was more common than previously reported studies. Positive family history was more frequent in primary congenital glaucoma although not statistically significant. PMID:24881602

  2. ASSOCIATION BETWEEN GLAUCOMA AND BLOOD GROUPS

    Directory of Open Access Journals (Sweden)

    F. Ghannadi R. Varmazyar

    2006-09-01

    Full Text Available There are reports from different countries that some types of glaucoma are associated with blood groups. This cross-sectional study was performed on 400 glaucomatous patients [100 patients in each group of Primary open angle glaucoma (POAG, chronic angle closure glaucoma (CACG, pseudoexfoliative glaucoma (PEXG and primary congenital glaucoma (PCG] and 400 blood donors as control group to assess the association between blood groups and glaucoma. All patients underwent ABO and Rh blood group testing. The prevalence of blood group A was 30% in the control group, 27% in POAG, 33% in CACA, 38% in PEXG and 36% in PCG. The prevalence of blood group B was 24% in the control group, 19% in POAG, 20% in CACG, 15% in PEXG and 34% in PCG (P < 0.025. The prevalence of blood group AB was 8% in the control group, 9% in POAG, 5% in CACG, 12% in PEXG, and 8% in PCG. The prevalence of blood group O was 38% in the control group, 45% in POAC, 42% in CACG, 35% in PEXG and 22% in PCG (P < 0.001. The prevalence of Rh+ was 88% in the control group, 84% in POAG, 87% in CACG, 86% in PEXG and 87% in PCG. Compared to control group, blood group B was more prevalent and blood group O was less prevalent in PCG. There was no association between other types of blood groups (ABO and Rh and PCG. There was no association between blood groups (ABO and Rh and other types of glaucoma.

  3. Mini-Sniffer on Lakebed

    Science.gov (United States)

    1974-01-01

    The original Mini-Sniffer on Rogers Dry Lake, adjacent to NASA's Flight Research Center, Edwards AFB. This version of the remotely-piloted vehicle had swept-back wings, tip rudders, nose canards, and an air breathing engine. The Mini-Sniffer was a remotely controlled, propeller-driven vehicle developed at the NASA Flight Research Center (which became the Dryden Flight Research Center, Edwards, California, in 1976) as a potential platform to sample the upper atmosphere for pollution. The vehicle, flown from 1975 to 1977, was one of the earliest attempts by NASA to develop an aircraft that could sense turbulence and measure natural and human-produced atmospheric pollutants at altitudes above 80,000 feet with a variable-load propeller that was never flight-tested. Three Mini-Sniffer vehicles were built. The number 1 Mini-Sniffer vehicle had swept wings with a span of 18 feet and canards on the nose. It flew 12 flights with the gas-powered engine at low altitudes of around 2,500 feet. The number 1 vehicle was then modified into version number 2 by removing the canards and wing rudders and adding wing tips and tail booms. Twenty flights were made with this version, up to altitudes of 20,000 feet. The number 3 vehicle had a longer fuselage, was lighter in weight, and was powered by the non-air-breathing hydrazine engine designed by NASA's Johnson Space Center in Houston, Texas. This version was designed to fly a 25-pound payload to an altitude of 70,000 feet for one hour or to climb to 90,000 feet and glide back. The number 3 Mini-Sniffer made one flight to 20,000 feet and was not flown again because of a hydrazine leak problem. All three versions used a pusher propeller to free the nose area for an atmospheric-sampling payload. At various times the Mini-Sniffer has been considered for exploration in the carbon dioxide atmosphere of the planet Mars, where the gravity (38 percent of that on Earth) would reduce the horsepower needed for flight.

  4. The medical management of glaucoma | Marais | South African ...

    African Journals Online (AJOL)

    Glaucoma is one of the leading causes of blindness worldwide. The main characteristic features include optic disc cupping, visual field loss, and in most instances a raised intraocular pressure. Primary open angle glaucoma accounts for nearly two thirds of all cases, while angle closure glaucoma contributes the majority of ...

  5. Goniodysgenesis in familial primary open-angle glaucoma

    NARCIS (Netherlands)

    Verbraak, F. D.; vd Berg, W.; Delleman, J. W.; Greve, E. L.

    1994-01-01

    Results of a pilot study to evaluate goniodysgenesis as a cause of familial open-angle glaucoma are reported. Patients with a familial high tension open-angle glaucoma and a goniodysgenetic chamber angle (n = 11), a number of their relatives with glaucoma (n = 12), and their relatives without

  6. Visual disability in Newly Diagnosed Primary open Angle Glaucoma ...

    African Journals Online (AJOL)

    Background: Glaucoma remains the second leading cause of blindness worldwide and the highest cause of irreversible blindness worldwide. In Nigeria, Glaucoma accounts for 16% of blindness and primary open angle glaucoma is the most prevalent clinical type. Aim: The aim of this study is to assess the visual disability ...

  7. Presentation of Primary Open Angle Glaucoma (POAG) at Lions ...

    African Journals Online (AJOL)

    Objective Primary open angle glaucoma (POAG) is the most common type of glaucoma in Africa. We carried out a study to determine the clinical presentation pattern of patients with primary open angle glaucoma (POAG) at a tertiary hospital in Malawi. Design A cross-sectional study. Setting Lions Sight First Eye Hospital—a ...

  8. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey

    OpenAIRE

    Daniel E. Grigera; Paulo Augusto Arruda Mello; Wilma Lelis Barbosa; Javier Fernando Casiraghi; Rodolfo Perez Grossmann; Alejo Peyret

    2013-01-01

    PURPOSE: The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. METHODS: An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1) and diagnosis (Part 2) of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. RESULTS: Fifty p...

  9. Late-Onset Endophthalmitis Secondary to Exposed Glaucoma Tube Implant in a Rare Case of Paediatric Glaucoma

    OpenAIRE

    Ranganath, Akshatha; Hashim, Adnan

    2011-01-01

    Glaucoma drainage implants (GDIs) are used to treat paediatric glaucoma resistant to conventional medical and surgical treatment, achieving good intraocular pressure (IOP) control and long-term success. Late endophthalmitis is a rare complication that may develop following GDI surgery. A 17-year-old male presented with acute endophthalmitis 2 years after Ahmed glaucoma valve implantation with pericardial patch graft for management of refractory glaucoma secondary to congenital ectropion uveae...

  10. Summer Mini Atomiade June 2016

    CERN Multimedia

    Staff Association

    2016-01-01

    The Mini Atomiade are coming to CERN! Members of Clubs supported by the CERN Staff Association and in conjunction with ASCERI (Association of the Sports Communities of the European Research Institutes) will be organising the summer games at the beginning of June. ASCERI aims to contribute to a united Europe through regular sports meetings, bringing together members of public Research Institutes at European level. The Association's members come from over 40 Research Institutes spanning 16 countries. Numerous sports and leisure activities are represented at regular events and each tournament is organised by a different research institute. Clubs in conjunction with the CERN Staff Association have sent teams to previous winter and summer games and now, the CERN Club’s Coordination Committee (CCC) has now taken on the challenge of organising a Mini Atomiade from Friday June 3rd to Monday June 6th 2016 in Divonne-les-Bains. The games are made up of four different tournaments/competitions: Small Fi...

  11. 24-h Efficacy of Glaucoma Treatment Options.

    Science.gov (United States)

    Konstas, Anastasios G P; Quaranta, Luciano; Bozkurt, Banu; Katsanos, Andreas; Garcia-Feijoo, Julian; Rossetti, Luca; Shaarawy, Tarek; Pfeiffer, Norbert; Miglior, Stefano

    2016-04-01

    Current management of glaucoma entails the medical, laser, or surgical reduction of intraocular pressure (IOP) to a predetermined level of target IOP, which is commensurate with either stability or delayed progression of visual loss. In the published literature, the hypothesis is often made that IOP control implies a single IOP measurement over time. Although the follow-up of glaucoma patients with single IOP measurements is quick and convenient, such measurements often do not adequately reflect the untreated IOP characteristics, or indeed the quality of treated IOP control during the 24-h cycle. Since glaucoma is a 24-h disease and the damaging effect of elevated IOP is continuous, it is logical that we should aim to understand the efficacy of all treatment options throughout the 24-h period. This article first reviews the concept and value of diurnal and 24-h IOP monitoring. It then critically evaluates selected available evidence on the 24-h efficacy of medical, laser and surgical therapy options. During the past decade several controlled trials have significantly enhanced our understanding on the 24-h efficacy of all glaucoma therapy options. Nevertheless, more long-term evidence is needed to better evaluate the 24-h efficacy of glaucoma therapy and the precise impact of IOP characteristics on glaucomatous progression and visual prognosis.

  12. [Study of corvitin efficiency in primary glaucoma].

    Science.gov (United States)

    Mykheĭtseva, I M; Kashyntseva, L T; Artemov, O V; Khramenko, N I

    2012-01-01

    There were concluded our results of animal experimental investigation and clinical observation of the quercetin-containing preparation corvitin (C) in primary glaucoma treatment. On the model of disease it is shown for rabbit, that introduction of 0.5 ml 2 % C as factious instillation into the eye a basely decreased eye blood flow was increased twice, mionectic at glaucoma eye hydrodynamics was normalized : the outflow of liquid increased on 58 %, inflow - on 52 %, intraocular pressure went down on 14%. Intravenous inflowing of C brought down expressed of oxidative stress - M[see text]A in blood is decreased on 40 %, level of endothelial dysfunction marker NO is increased on 70 %. On the model of glaucoma for rats C, entered protractedly, showed the neuroprotective actions on the neurons of retina, promoting survivability of ganglion cells, that it is shown on histological preparations. Application C in the clinic of glaucoma (intravenously a 0.5 g of preparation in 100 ml of solution) improved for patients a blood supply in the eye on 25 %, and also rendered a positive antioxidant and metabolic effect. Noted positive influences of C concurrently to important pathogeneses factors such as regional eye blood supply, eye hydrodynamics, oxidative stress, metabolic changes, survival of retina neurons grounds to talk about new strategy of pathogenesis therapy of glaucoma.

  13. Mini-guide til DGNB

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Guiden giver et kort indblik i formålet med de enkelte kriterier i en DGNB- bæredygtighedsvurdering, samt i hvordan der kan måles på kriterierne. Mini-guiden tager afsæt i systemet for certificering af Nybyggede kontor-og erhvervsbyggerier, som er det første og grundlæggende system i DGNB, som al...

  14. Development of mini VSAT system

    Science.gov (United States)

    Lu, Shyue-Ching; Chiu, Wu-Jhy; Lin, Hen-Dao; Shih, Mu-Piao

    1992-03-01

    This paper presents the mini VSAT (very small aperture terminal) system, which is a low cost networking system providing economical alternatives to the business world's datacom needs. The system is designed to achieve the highest possible performance/price ratio for private VSAT networks that range from a few tens of remote terminals to large networks of several thousands remote terminals. The paper describes the system architecture, major features, hardware and software structure, access protocol and performance of the developed system.

  15. Short term outcome of Ahmed glaucoma valve implantation in management of refractory glaucoma in a tertiary hospital in Oman

    Science.gov (United States)

    Shah, Manali R.; Khandekar, Rajiv B.; Zutshi, Rajiv; Mahrooqi, Rahima

    2013-01-01

    Background: We present outcomes of Ahmed Glaucoma Valve (AGV) implantation in treating refractory glaucoma in a tertiary hospital in Oman. Refractory glaucoma was defined as previously failed conventional glaucoma surgery and an uncontrolled intraocular pressure (IOP) of more than 21 mm Hg despite treatment with three topical and/or oral therapy. Materials and Methods: This historical cohort study was conducted in 2010. Details of medical and surgical treatment were recorded. Ophthalmologists examined eyes and performed glaucoma surgeries using AGV. The best corrected distant vision, IOP, and glaucoma medications were prospectively reviewed on 1st day, 1st, 6th, 12th week postoperatively, and at the last follow up. Result: Glaucoma specialists examined and treated 40 eyes with refractory glaucoma of 39 patients (20 males + 19 females). Neo-vascular glaucoma was present in 23 eyes. Vision before surgery was glaucoma medications (2.38; SD 1.1) was reduced compared to the mean number of postoperative medications (1.92; SD 0.9) at 12 weeks. Conclusion: We succeeded in reducing visual disabilities and the number of anti-glaucoma medications used to treat refractory glaucoma by AGV surgery. PMID:23772122

  16. Anti-vascular endothelial growth factor for neovascular glaucoma.

    Science.gov (United States)

    Simha, Arathi; Braganza, Andrew; Abraham, Lekha; Samuel, Prasanna; Lindsley, Kristina

    2013-10-02

    study participants. Currently available evidence is insufficient to evaluate the effectiveness of anti-VEGF treatments, such as intravitreal ranibizumab or bevacizumab, as an adjunct to conventional treatment in lowering IOP in NVG. Well designed RCTs are needed to address this issue, particularly trials that evaluate long-term (at least six months) benefits and risks since the effects of anti-VEGF agents may be short-term only. An RCT comparing anti-VEGF agents with no anti-VEGF agents taking into account the need for co-interventions, such as panretinal photocoagulation (PRP), glaucoma shunt procedures, cyclodestructive procedures, cataract surgery, and deep vitrectomy, could be of use to investigate the additional beneficial effect of anti-VEGF agents in treating NVG. Since decisions for when and which co-interventions should be used are based on clinical criteria, they would not be appropriate for randomization. However, the design of a study on this topic should aim to balance groups by stratification of co-intervention at time of randomization or by enrolling a sufficient number of participants to conduct subgroup analysis by co-interventions (ideally 15 participants per treatment group for each subgroup). Alternatively, the inclusion criteria for a trial could limit participants to those who receive the same co-intervention.

  17. Ventriculoperitoneal shunt infection in Haji Adam Malik Hospital, Medan

    Science.gov (United States)

    Dharmajaya, R.

    2018-03-01

    Installation of ventriculoperitoneal shunts (VP) represented a substantial progress in the neurosurgical management of hydrocephalus in children. However, infection is the most commonpostoperative complication of aventriculoperitoneal shunt. It is important because it is related to substantial morbidity and mortality, and exerts a negative impact on the quality of life of patients. We retrospectively analyzed all 20 cases of shunt infection from 2013 to 2016. The types of infections found were exposed shunts15 cases (75%), and 5 cases of ventriculitis (25%). Length of infection time which calculated from the beginning of surgery was 350.20 days or 11 months. The most common pathogen types are S. epidermidis followed by P. aeruginosa, E. coli, and A. baumanii. There were many risk factors for shunt infection, but the interesting fact was the level of pre-operative albumin. There was a significant difference between low albumin levels (<3.0) and normal albumin (≥3.0) levels against the risk of exposure shunt, p = 0.015. It means there is asignificant difference between low pre-operative albumin and normal level for the risk of theexposed shunt.

  18. A plasma polymerization technique to overcome cerebrospinal fluid shunt infections

    Energy Technology Data Exchange (ETDEWEB)

    Coekeliler, D [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey); Caner, H [Department of Neurosurgery, School of Medicine, Baskent University, 06610, Ankara (Turkey); Zemek, J [Institute of Physics, Academy of Sciences of the Czech Republic, Cukrovarnicka 10, 162 53, Prague, Czech Republic (Czech Republic); Choukourov, A [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Biederman, H [Department of Macromolecular Physics, Charles University, V Holesovickach 2, 18000 Prague (Czech Republic); Mutlu, M [Plasma Aided Bioengineering and Biotechnology Research Laboratory, Engineering Faculty, Hacettepe University, 06532, Ankara (Turkey)

    2007-03-01

    Prosthetic devices, mainly shunts, are frequently used for temporary or permanent drainage of cerebrospinal fluid. The pathogenesis of shunt infection is a very important problem in modern medicine and generally this is characterized by staphylococcal adhesion to the cerebrospinal fluid shunt surfaces. In this paper, the prevention of the attachment of test microorganism Staphylococcus epidermidis on the cerebrospinal fluid shunt surfaces by 2-hydroxyethylmethacrylate (HEMA) precursor modification in the plasma polymerization system, is reported. Different plasma polymerization conditions (RF discharge power 10-20-30 W, exposure time 5-10-15 min) were employed during the surface modification. The surface chemistry and topology of unmodified and modified shunts was characterized by x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and atomic force microscopy (AFM). Also, static contact angle measurements were performed to state the change of surface hydrophilicity. All samples were tested in vitro with Staphylococcus epidermidis. A plasma-polymerized HEMA film (PP HEMA) was found to be an alternative simple method to decrease the microorganism attachment and create bacterial anti-fouling surfaces. The attachment of the model microorganism Staphylococcus epidermidis on the shunt surface modified by PP HEMA at 20 W and 15 min was reduced 62.3% if compared to the unmodified control surface of the shunt.

  19. Research on spark discharge of floating roof tank shunt

    International Nuclear Information System (INIS)

    Bi, Xiaolei; Liu, Quanzhen; Liu, Baoquan; Gao, Xin; Hu, Haiyan; Liu, Juan

    2013-01-01

    In order to quantitatively analyze the spark discharge risk of floating roof tank shunts, the breakdown voltage of shunt has been calculated by Townsend theory, the shunt spark discharge experiment is carried out by using 1.2/50 μs impulse voltage wave, and the relationship between breakdown voltage of shunt spark discharge and air gap is analyzed. It has been indicated by theoretical analysis and experimental study that the small gap is more easily cause spark discharge than the big gap when the contact between shunt and tank shell is poor. When air gap distance is equal to 0.1 cm, average breakdown voltage is 5280 V. When the air gap distance is less than 0.3 cm, experiment data agree well with Townsend theory. Therefore, in the condition of small gap, Townsend theory can be used to calculated breakdown voltage of shunt. Finally, based on the above conclusions, improvements for avoiding the spark discharge risk of shunt of floating roof tanks have been proposed.

  20. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Directory of Open Access Journals (Sweden)

    Lindsay Van den Bossche

    Full Text Available Non-alcoholic fatty liver disease (NAFLD is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS and intrahepatic portosystemic shunts (IHPSS was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS P<0.01; IHPSS P = 0.042. Involvement of lipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  1. Aberrant hepatic lipid storage and metabolism in canine portosystemic shunts.

    Science.gov (United States)

    Van den Bossche, Lindsay; Schoonenberg, Vivien A C; Burgener, Iwan A; Penning, Louis C; Schrall, Ingrid M; Kruitwagen, Hedwig S; van Wolferen, Monique E; Grinwis, Guy C M; Kummeling, Anne; Rothuizen, Jan; van Velzen, Jeroen F; Stathonikos, Nikolas; Molenaar, Martijn R; Helms, Bernd J; Brouwers, Jos F H M; Spee, Bart; van Steenbeek, Frank G

    2017-01-01

    Non-alcoholic fatty liver disease (NAFLD) is a poorly understood multifactorial pandemic disorder. One of the hallmarks of NAFLD, hepatic steatosis, is a common feature in canine congenital portosystemic shunts. The aim of this study was to gain detailed insight into the pathogenesis of steatosis in this large animal model. Hepatic lipid accumulation, gene-expression analysis and HPLC-MS of neutral lipids and phospholipids in extrahepatic (EHPSS) and intrahepatic portosystemic shunts (IHPSS) was compared to healthy control dogs. Liver organoids of diseased dogs and healthy control dogs were incubated with palmitic- and oleic-acid, and lipid accumulation was quantified using LD540. In histological slides of shunt livers, a 12-fold increase of lipid content was detected compared to the control dogs (EHPSS Plipid-related genes to steatosis in portosystemic shunting was corroborated using gene-expression profiling. Lipid analysis demonstrated different triglyceride composition and a shift towards short chain and omega-3 fatty acids in shunt versus healthy dogs, with no difference in lipid species composition between shunt types. All organoids showed a similar increase in triacylglycerols after free fatty acids enrichment. This study demonstrates that steatosis is probably secondary to canine portosystemic shunts. Unravelling the pathogenesis of this hepatic steatosis might contribute to a better understanding of steatosis in NAFLD.

  2. Portosystemic shunts for extrahepatic portal hypertension in children.

    Science.gov (United States)

    Tocornal, J; Cruz, F

    1981-07-01

    Twenty-three children with prehepatic portal hypertension and hemorrhage due to ruptured esophagogastric varices had portosystemic shunts. Their ages ranged from two years and seven months to 15 years. Eleven were less than eight years of age. Twenty patients had portal vein cavernomatosis and three patients had double portal veins. In 21 patients, a mesocaval type of shunt was done. A splenorenal shunt was performed in two. There was no surgical mortality. Two shunts occluded, both in rather young infants--two years and seven months and three years of age. In all the others, there was no further bleeding, and the shunts remained patent, as shown by abdominal angiograms. Neuropsychiatric disorders, probably due to hepatic encephalopathy, occurred in only one patient. On the basis of this favorable experience, we believe that an elective portosystemic shunt should, in general, be performed upon children with prehepatic portal hypertension after one major variceal hemorrhage. We favor a mesocaval type of shunt in these children because of the larger diameter of the vessels involved in the anastomosis and because it preserves the spleen, maintaining defense against subsequent infection.

  3. Optical Coherence Tomography Angiography Vessel Density in Healthy, Glaucoma Suspect, and Glaucoma Eyes

    Science.gov (United States)

    Yarmohammadi, Adeleh; Zangwill, Linda M.; Diniz-Filho, Alberto; Suh, Min Hee; Manalastas, Patricia Isabel; Fatehee, Naeem; Yousefi, Siamak; Belghith, Akram; Saunders, Luke J.; Medeiros, Felipe A.; Huang, David; Weinreb, Robert N.

    2016-01-01

    Purpose The purpose of this study was to compare retinal nerve fiber layer (RNFL) thickness and optical coherence tomography angiography (OCT-A) retinal vasculature measurements in healthy, glaucoma suspect, and glaucoma patients. Methods Two hundred sixty-one eyes of 164 healthy, glaucoma suspect, and open-angle glaucoma (OAG) participants from the Diagnostic Innovations in Glaucoma Study with good quality OCT-A images were included. Retinal vasculature information was summarized as a vessel density map and as vessel density (%), which is the proportion of flowing vessel area over the total area evaluated. Two vessel density measurements extracted from the RNFL were analyzed: (1) circumpapillary vessel density (cpVD) measured in a 750-μm-wide elliptical annulus around the disc and (2) whole image vessel density (wiVD) measured over the entire image. Areas under the receiver operating characteristic curves (AUROC) were used to evaluate diagnostic accuracy. Results Age-adjusted mean vessel density was significantly lower in OAG eyes compared with glaucoma suspects and healthy eyes. (cpVD: 55.1 ± 7%, 60.3 ± 5%, and 64.2 ± 3%, respectively; P glaucoma and healthy eyes, the age-adjusted AUROC was highest for wiVD (0.94), followed by RNFL thickness (0.92) and cpVD (0.83). The AUROCs for differentiating between healthy and glaucoma suspect eyes were highest for wiVD (0.70), followed by cpVD (0.65) and RNFL thickness (0.65). Conclusions Optical coherence tomography angiography vessel density had similar diagnostic accuracy to RNFL thickness measurements for differentiating between healthy and glaucoma eyes. These results suggest that OCT-A measurements reflect damage to tissues relevant to the pathophysiology of OAG. PMID:27409505

  4. [Long-term outcomes of Ahmed glaucoma valve implantation for treating refractory glaucoma].

    Science.gov (United States)

    Xu, Yumei; Hong, Tao; Li, Wanming

    2015-02-10

    To explore the efficacies and complications of Ahmed glaucoma valve implantation for treating refractory glaucoma. A retrospective study of case series was conducted for 24 patients (26 eyes) with refractory glaucoma from February 2001 to July 2008 at our hospital. Ahmed glaucoma valve implantation was performed. Pre- and post-operative best spectacle-corrected visual acuity (BSCVA), intraocular pressure (IOP), number of medications and complications were recorded and analyzed. The follow-up period was 58-159 months. The post-operative values of IOP were 13.02+/-6.79, 11.43+/-5.24 and 18.56+/-6.43 mmHg at 1 day, 1 month and the last follow-up respectively. There were significant difference when compared with pre-operative IOP (37.59+/-10.76 mmHg, P glaucoma drugs after glaucoma valve implantation and the average number of medication was 1.72+/-0.98. There was significant difference with the pre-operative medication number 2.7 ± 0.7 (P = 0.001). The surgical success rate was 73.1%. And the causes of failure were endophthalmitis, corneal endothelial decompensation, persistent conjunctival wound non-healing, glaucoma valve exposure and loss of light perception.Early postoperative complications were ocular hypotony, shallow anterior chamber, hyphema, transient high IOP and tube occlusion. And long-term complications included encapsulated cyst formation, tube exposure, corneal endothelial decompensation and endophthalmitis. Ahmed glaucoma valve implantation is efficacious for refractory glaucoma.However, clinicians should pay attention to the prevention and treatment of complications.

  5. A prospective comparative study on neovascular glaucoma and non-neovascular refractory glaucoma following Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Li, Zheng; Zhou, Minwen; Wang, Wei; Huang, Wenbin; Chen, Shida; Li, Xingyi; Gao, Xinbo; Zhang, Xiulan

    2014-01-01

    Neovascular glaucoma is a refractory disease, and difficult to manage. The aim of this study was to evaluate the clinical outcomes of Ahmed glaucoma valve implantation (AGVI) in neovascular glaucoma (NVG) and non-NVG patients. This prospective, non-randomized study included 55 eyes of 55 patients with refractory glaucoma; 27 had NVG (NVG group) and 28 had non-NVG (non-NVG group). All of the patients underwent AGVI. The NVG group was adjunctively injected with intravitreal ranibizumab/bevacizumab (IVR/IVB) before AGVI. Intraocular pressure (IOP) was the primary outcome measure in this study. Surgical success rate, number of antiglaucoma medications used, best corrected visual acuity (BCVA), and postoperative complications were analyzed between the groups. All of the patients completed the study (follow-up of 12 months). Kaplan-Meier survival curve analysis indicated that the qualified success rates in the NVG and non-NVG groups at 12 months were 70.5% and 92.9%, respectively; this difference was significant (P = 0.036). The complete success rates in the NVG and non-NVG groups at 12 months were 66.7% and 89.3%, respectively (P = 0.049). Compared with preoperative examinations, the postoperative mean IOP and use of medications were significantly lower at all follow-up time points in both groups (all P glaucoma, but the success rate of surgery was related to the type of refractory glaucoma. The complete and qualified success rates of NVG patient adjunctive anti-vascular endothelial growth factor treatment are still lower than those of non-NVG patients.

  6. Evaluation of Ocular Surface Disease in Patients with Glaucoma

    Science.gov (United States)

    Mathews, Priya M.; Ramulu, Pradeep Y.; Friedman, David S.; Utine, Canan A.; Akpek, Esen K.

    2013-01-01

    Purpose To evaluate the subjective and objective measures of ocular surface disease in patients with glaucoma. Design Cross-sectional study. Participants Sixty-four glaucoma subjects with bilateral visual field (VF) loss and 59 glaucoma suspects with normal VFs. Methods Consecutive patients were recruited prospectively from the Wilmer Eye Institute Glaucoma Clinic. Main Outcome Measures Tear film breakup time (TBUT), corneal staining score (0–15), and Schirmer’s test results were included as objective metrics, whereas the Ocular Surface Disease Index (OSDI) questionnaire was administered to assess symptoms. Total OSDI score, vision-related subscore (derived from questions about vision and task performance), and discomfort-related subscore (derived from questions about ocular surface discomfort) were calculated for each subject. Results Seventy-five percent (48/64) of glaucoma subjects and 41% (24/59) of glaucoma suspects were receiving topical medications. The corneal staining grade was greater in glaucoma subjects than in glaucoma suspects (6.4 vs. 4.1; P0.20 for both). Multivariate regression models showed that topical glaucoma therapy burden was associated with a significantly higher total corneal staining grade (β, +0.9 for each additional glaucoma drop; 95% confidence interval [CI], 0.5–1.3; P0.20 for both). Glaucoma subjects had significantly higher total OSDI scores than glaucoma suspects (16.7 vs. 7.9; Pglaucoma group (11.1 vs. 3.3; Pglaucoma therapy burden was not associated with higher total OSDI score or vision- or discomfort-related subscore (P>0.20 for all). Conclusions Glaucoma is associated with significant ocular surface disease, and topical glaucoma therapy burden seems predictive of corneal staining severity. However, OSDI is a poor metric for capturing ocular surface disease in glaucoma because symptoms seem to be related largely to VF loss. PMID:23714318

  7. Anti-glaucoma potential of Heliotropium indicum Linn in experimentally-induced glaucoma

    OpenAIRE

    Kyei, Samuel; Koffuor, George Asumeng; Ramkissoon, Paul; Owusu-Afriyie, Osei

    2015-01-01

    Background Heliotropium indicum is used as a traditional remedy for hypertension in Ghana. The aim of the study was to evaluate the anti-glaucoma potential of an aqueous whole plant extract of H. indicum to manage experimentally-induced glaucoma. Methods The percentage change in intraocular pressure (IOP), after inducing acute glaucoma (15 mLkg?1 of 5?% dextrose, i.v.), in New Zealand White rabbits pretreated with Heliotropium indicum aqueous extract (HIE) (30?300 mgkg?1), acetazolamide (5 mg...

  8. Ahmed glaucoma valve in post-penetrating-keratoplasty glaucoma: A critically evaluated prospective clinical study

    Science.gov (United States)

    Panda, Anita; Prakash, Vadivelu Jaya; Dada, Tanuj; Gupta, Anoop Kishore; Khokhar, Sudarshan; Vanathi, Murugesan

    2011-01-01

    Aim: The aim was to evaluate the outcome of Ahmed glaucoma valve (AGV) in post-penetrating-keratoplasty glaucoma (PKPG). Materials and Methods: In this prospective study, 20 eyes of 20 adult patients with post-PKPG with intraocular pressure (IOP) >21 mmHg, on two or more antiglaucoma medications, underwent AG (model FP7) implantation and were followed up for a minimum of 6 months. Absolute success was defined as 5 glaucoma managed by AGV implantation revealed a satisfactory outcome up to 6 months of follow-up. PMID:21586837

  9. Muzzle shunt augmentation of conventional railguns

    International Nuclear Information System (INIS)

    Parker, J.V.

    1991-01-01

    This paper reports on augmentation which is a technique for reducing the armature current and hence the armature power dissipation in a plasma armature railgun. In spite of the advantages, no large augmented railguns have been built, primarily due to the mechanical and electrical complexity introduced by the extra conductors required. it is possible to achieve some of the benefits of augmentation in a conventional railgun by diverting a fraction φ of the input current through a shunt path at the muzzle of the railgun. In particular, the relation between force and armature current is the same as that obtained in an n-turn, series-connected augmented railgun with n = 1/(1 - φ). The price of this simplification is a reduction in electrical efficiency and some additional complexity in the external electrical system

  10. Prevention and treatment of complications after transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    XUE Hui

    2016-02-01

    Full Text Available The application of transjugular intrahepatic portosystemic shunt (TIPS in the treatment of cirrhotic portal hypertension has been widely accepted both at home and abroad. This article focuses on the fatal complications of TIPS (including intraperitoneal bleeding and acute pulmonary embolism, shunt failure, and recurrent portosystemic hepatic encephalopathy, and elaborates on the reasons for such conditions and related preventive measures, in order to improve the accuracy and safety of intraoperative puncture, reduce common complications such as shunt failure and hepatic encephalopathy, and improve the clinical effect of TIPS in the treatment of cirrhotic portal hypertension.

  11. Spinal cord arteriovenous shunts: from imaging to management

    International Nuclear Information System (INIS)

    Rodesch, G.; Lasjaunias, P.

    2003-01-01

    Spinal cord arteriovenous shunts (SCAVSs) are either fistulas or niduses that can be separated in four different groups according to their localization and relationship to the dura. Paraspinal AVSs are located outside the spine and are responsible for neurological symptoms because of cord compression by ertatic veins, venous congestion or arterial steal. Epidural shunts are located in the epidural space and drain in epidural veins with secondary intradural congestion. Dural shunts are embedded in the dura, produce a cord venous myelopathy after draining through veins that either pierce the dura far from a nerve root or accompany a nerve root. Intradural shunts affect the cord, the roots or the filum. Additionally, they can be classified according to their potential relationships with genetics, vascular biological features and angiogenesis into genetic hereditary lesions (hereditary hemorrhagic telangiectasia), genetic non-hereditary lesions (multiple lesions with metameric links) and single lesions (AVMs or micro AVFs). MRI and MRA are able to visualise SCAVS early after the onset of clinical symptoms. The type of shunt and its localization may remain difficult to be precise. Angiography remains the gold standard for analysis of the anatomical, morphological and architectural features necessary for therapeutic decisions in both paediatric and adult populations. In our series, embolisation is chosen in first intention whatever the type of shunt responsible for the clinical symptoms and glue is preferably used. In paraspinal, dural or epidural arteriovenous shunts, the goal of treatment should be complete closure of the shunt. A complete cure by embolization is rather easily achieved in paraspinal lesions. Failure of endovascular therapy in dural or epidural shunts must bring the patient to surgery. The prognosis of most intradural shunts seems better than previously thought, even after haemorrhage. In intradural spinal cord arteriovenous shunts, embolisation

  12. Trabecular meshwork stiffness in glaucoma.

    Science.gov (United States)

    Wang, Ke; Read, A Thomas; Sulchek, Todd; Ethier, C Ross

    2017-05-01

    Alterations in stiffness of the trabecular meshwork (TM) may play an important role in primary open-angle glaucoma (POAG), the second leading cause of blindness. Specifically, certain data suggest an association between elevated intraocular pressure (IOP) and increased TM stiffness; however, the underlying link between TM stiffness and IOP remains unclear and requires further study. We here first review the literature on TM stiffness measurements, encompassing various species and based on a number of measurement techniques, including direct approaches such as atomic force microscopy (AFM) and uniaxial tension tests, and indirect methods based on a beam deflection model. We also briefly review the effects of several factors that affect TM stiffness, including lysophospholipids, rho-kinase inhibitors, cytoskeletal disrupting agents, dexamethasone (DEX), transforming growth factor-β 2 (TGF-β 2 ), nitric oxide (NO) and cellular senescence. We then describe a method we have developed for determining TM stiffness measurement in mice using a cryosection/AFM-based approach, and present preliminary data on TM stiffness in C57BL/6J and CBA/J mouse strains. Finally, we investigate the relationship between TM stiffness and outflow facility between these two strains. The method we have developed shows promise for further direct measurements of mouse TM stiffness, which may be of value in understanding mechanistic relations between outflow facility and TM biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. A link between diabetes mellitus and glaucoma

    DEFF Research Database (Denmark)

    Horwitz, A.; Petrovski, B.E; Petrovski, G.

    2016-01-01

    -year follow-up period. The National Danish Registry of Medicinal Products Statistics was used to identify all claimed prescriptions for glaucoma medication and anti-diabetic drugs. Comorbidities with diabetic retinopathy and diabetic nephropathy were identified using the ICD-10 classification......-diabetic drugs at any time during the study period had a significantly higher overall relative risk of glaucoma (RR = 5.11, p age, gender, diabetic retinopathies and calendar year-fixed effects (RR = 2.05, p ... of glaucoma overall, while treatment with β-blocker and RAS, in combination, are associated with a significantly lower risk (HR = 0.87). Conclusions Use of anti-diabetic drugs is strongly associated with use of anti-glaucomatous drugs. Diabetic complication as well as concomitant antihypertensive medications...

  14. Ahmed glaucoma valve in children: A review☆

    Science.gov (United States)

    Nassiri, Nariman; Nouri-Mahdavi, Kouros; Coleman, Anne L.

    2011-01-01

    Pediatric glaucoma is potentially a blinding disease. Although goniotomy and trabeculotomy are associated with good early success rates, eventually 20% of these procedures fail and many children will require additional surgery to control the IOP in the long-term. In this review, we reported that adequate IOP control can be achieved with the placement of Ahmed glaucoma valve and can last 5 or more years. However, most patients will need one or more glaucoma medications at some point after surgery. In addition, the implants may be associated with pupillary irregularities, lenticular opacification as well as tube-related complications, particularly in the first year of life, as the globe is enlarging with age. PMID:23960945

  15. BILATERAL STEROID INDUCED GLAUCOMA IN VERNAL KERATOCONJUNCTIVITIS

    Directory of Open Access Journals (Sweden)

    Bangal Surekha V, Bankar Mahima S, Bhandari Akshay J, Kalkote Prasad R

    2015-01-01

    Full Text Available Vernal Keratoconjunctivits (VKC is a bilateral recurrent allergic interstitial conjunctival inflammation with a periodic seasonal incidence and of self limiting nature, mainly affecting the younger population. Patients of VKC on steroid therapy are at higher risk of developing steroid induced glaucoma. Raised intraocular pressure due to steroids typically occurs within few weeks of starting steroid therapy and comes back to normal on immediate stoppage of steroids. A case of steroid induced glaucoma in a 30 years old female with vernal keratoconjunctivitis. She was on topical steroids for 3-4 years. She was incompliant with the instructions to stop steroids. She eventually developed steroid induced glaucoma and glaucomatous optic neuropathy with tunnel vision.

  16. Unilateral glaucoma in Sotos syndrome (cerebral gigantism).

    Science.gov (United States)

    Yen, M T; Gedde, S J; Flynn, J T

    2000-12-01

    To report a patient with unilateral glaucoma associated with Sotos syndrome. Sotos syndrome (cerebral gigantism) is a disorder of growth and development with characteristic facial changes and normal endocrine function. Ocular manifestations may also include megalocornea, iris hypoplasia, cataracts, megalophthalmos, strabismus, nystagmus, and retinal dystrophy. Case report. A 50 year-old man with the clinical features of Sotos syndrome presented with complaints of decreased vision in the left eye. Ophthalmologic examination revealed bilateral megalocornea, megalophthalmos, iris hypoplasia and transillumination defects, cataracts, and unilateral glaucoma. Intraocular pressure was lowered, and visual field loss was stabilized with topical medications. Sotos syndrome patients should be examined routinely to allow for early detection and treatment of potential ocular problems, including glaucoma.

  17. Current concepts in the pathophysiology of glaucoma

    Directory of Open Access Journals (Sweden)

    Agarwal Renu

    2009-01-01

    Full Text Available Glaucoma, the second leading cause of blindness, is characterized by changes in the optic disc and visual field defects. The elevated intraocular pressure was considered the prime factor responsible for the glaucomatous optic neuropathy involving death of retinal ganglion cells and their axons. Extensive investigations into the pathophysiology of glaucoma now reveal the role of multiple factors in the development of retinal ganglion cell death. A better understanding of the pathophysiological mechanisms involved in the onset and progression of glaucomatous optic neuropathy is crucial in the development of better therapeutic options. This review is an effort to summarize the current concepts in the pathophysiology of glaucoma so that newer therapeutic targets can be recognized. The literature available in the National Medical Library and online Pubmed search engine was used for literature review.

  18. A Quantitative Analysis of the Relationship between Medicare Payment and Service Volume for Glaucoma Procedures from 2005 through 2009.

    Science.gov (United States)

    Gong, Dan; Jun, Lin; Tsai, James C

    2015-05-01

    To calculate the association between Medicare payment and service volume for 6 commonly performed glaucoma procedures. Retrospective, longitudinal database study. A 100% dataset of all glaucoma procedures performed on Medicare Part B beneficiaries within the United States from 2005 to 2009. Fixed-effects regression model using Medicare Part B carrier data for all 50 states and the District of Columbia, controlling for time-invariant carrier-specific characteristics, national trends in glaucoma service volume, Medicare beneficiary population, number of ophthalmologists, and income per capita. Payment-volume elasticities, defined as the percent change in service volume per 1% change in Medicare payment, for laser trabeculoplasty (Current Procedural Terminology [CPT] code 65855), trabeculectomy without previous surgery (CPT code 66170), trabeculectomy with previous surgery (CPT code 66172), aqueous shunt to reservoir (CPT code 66180), laser iridotomy (CPT code 66761), and scleral reinforcement with graft (CPT code 67255). The payment-volume elasticity was nonsignificant for 4 of 6 procedures studied: laser trabeculoplasty (elasticity, -0.27; 95% confidence interval [CI], -1.31 to 0.77; P = 0.61), trabeculectomy without previous surgery (elasticity, -0.42; 95% CI, -0.85 to 0.01; P = 0.053), trabeculectomy with previous surgery (elasticity, -0.28; 95% CI, -0.83 to 0.28; P = 0.32), and aqueous shunt to reservoir (elasticity, -0.47; 95% CI, -3.32 to 2.37; P = 0.74). Two procedures yielded significant associations between Medicare payment and service volume. For laser iridotomy, the payment-volume elasticity was -1.06 (95% CI, -1.39 to -0.72; P payment, laser iridotomy service volume increased by 1.06%. For scleral reinforcement with graft, the payment-volume elasticity was -2.92 (95% CI, -5.72 to -0.12; P = 0.041): for every 1% decrease in CPT code 67255 payment, scleral reinforcement with graft service volume increased by 2.92%. This study calculated the association

  19. [Influence of Luxury Foodstuffs on Glaucoma].

    Science.gov (United States)

    Huber-van der Velden, K K

    2017-02-01

    The term "luxury foodstuffs" refers to foods which are not consumed because of their nutritional value. Classic modern luxury foodstuffs are alcohol, caffeine-containing drinks, cocoa, sugar and tobacco. The following review article examines some of these modern luxury foodstuffs in detail, as well as their influence on glaucoma. Thus, small quantities of alcohol lower high intraocular pressure and have a positive influence on the blood circulation of the optic nerve. In addition, red wine polyphenols exert vasoprotective effects. In general, however, alcohol consumption appears to have no significant effect on the prevalence of glaucoma. The most important source of caffeine intake is coffee consumption. In some studies, coffee consumption caused no changes in intraocular pressure, while others reported a rise. A large study showed a connection between heavy coffee consumption and the risk of pseudoexfoliation glaucoma. Green and black teas are rich sources of flavonoids with antioxidant activity. In addition, a slight trend for lowering the intraocular pressure has been measured. As regards chocolate, flavonoid-rich dark chocolate should be favoured, due to its antioxidant activity. It lowers blood pressure and improves endothelium-dependent vascular relaxation. Excessive sugar consumption over many years can lead to increased body mass index (BMI) and type 2 diabetes. Many studies show a positive relationship between BMI and intraocular pressure. Some studies have identified significant correlations between type 2 diabetes and the risk of glaucoma. Smoking is a very widespread stimulant; it narrows the blood vessels and thus reduces the blood circulation of the optic nerve. Otherwise, studies on the role of smoking as a risk factor for glaucoma have been very inconsistent. Luxury foodstuffs may effect glaucoma and should be included in the medical history. Georg Thieme Verlag KG Stuttgart · New York.

  20. Management of Blood Pressure in Patients with Glaucoma.

    Science.gov (United States)

    Levine, Russell M; Yang, Alina; Brahma, Venkatesh; Martone, James F

    2017-09-19

    Ocular perfusion pressure (OPP) is defined as the difference between BP and intraocular pressure (IOP). With low BP comes low OPP and resultant ischemic damage to the optic nerve, leading to glaucoma progression. The purpose of this article is to review the literature on BP as it relates to glaucoma and to create a forum of discussion between ophthalmologists and internal medicine specialists. Both high and low BP has been linked glaucoma. Low BP is particularly associated with glaucoma progression in normal-tension glaucoma (NTG) patients. Patients who have low nighttime BP readings are at highest risk of progression of their glaucoma. Internal medicine specialists and ophthalmologists should consider the relationship between BP and glaucoma when treating patients with concomitant disease. Too-low nighttime BP should be avoided. Ambulatory blood pressure monitoring is a useful tool to identify patients at greatest risk for progression.

  1. Definition, Classification, and Pathophysiology of Canine Glaucoma.

    Science.gov (United States)

    Pizzirani, Stefano

    2015-11-01

    Glaucoma is a common ocular condition in humans and dogs leading to optic nerve degeneration and irreversible blindness. Primary glaucoma is a group of spontaneous heterogeneous diseases. Multiple factors are involved in its pathogenesis and these factors vary across human ethnic groups and canine breeds, so the clinical phenotypes are numerous and their classification can be challenging and remain superficial. Aging and oxidative stress are major triggers for the manifestation of disease. Multiple, intertwined inflammatory and biochemical cascades eventually alter cellular and extracellular physiology in the optic nerve and trabecular meshwork and lead to vision loss. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Clinical observation on Ahmed glaucoma valve implantation for teenagers with refractory glaucoma

    Directory of Open Access Journals (Sweden)

    Dong-Dao Song

    2016-06-01

    Full Text Available AIM:To observe the clinical effect of Ahmed glaucoma valve(AGVimplantation for teenagers with refractory glaucoma. METHODS: Twenty-seven patients(27 eyeswith refractory glaucoma were treated with AGV implantation in our hospital from October 2012 to October 2014. The patients were followed up for 12mo. The success rate of the operation, postoperative intraocular pressure, the best corrected visual acuity, as well as complications were recorded. RESULTS: The success rate of the operation was 85%. The intraocular pressure of the 27 patients decreased from 48.3±8.3mmHg before operations to 21.4±8.1mmHg(PPCONCLUSION: AGV implantation is characterized by a high success rate, simple operation, less complications and is an effective treatment for refractory glaucoma in adolescents.

  3. Scoliosis and Syringomyelia With Chiari Malformation After Lumbar Shunting

    Directory of Open Access Journals (Sweden)

    Hsin-Hung Chen

    2010-07-01

    Full Text Available Unsteady gait was noted in a 2-year-old boy with a lumboperitoneal (LP shunt that had been inserted 1 year earlier for increased head circumference caused by communicating hydrocephalus. Scoliosis was also noted during postoperative follow-up. Magnetic resonance imaging revealed new hindbrain tonsillar herniation and an extensive syrinx from C3 to L1. The malfunctioning LP shunt was removed and posterior fossa decompression with ventriculoperitoneal shunt insertion was performed. The unsteady gait recovered completely and scoliosis improved. Magnetic resonance imaging demonstrated resolution of the syrinx and tonsillar herniation. Acquired Chiari I malformation after LP shunt is well documented; usually, patients have no symptoms. This is the first report to have all the cause and effect mechanisms among syringomyelia, scoliosis and Chiari I malformation in 1 patient. We review the literature and discuss the possible mechanisms.

  4. Optimization methods for the Train Unit Shunting Problem

    DEFF Research Database (Denmark)

    Haahr, Jørgen Thorlund; Lusby, Richard Martin; Wagenaar, Joris Camiel

    2017-01-01

    We consider the Train Unit Shunting Problem, an important planning problem for passenger railway operators. This problem entails assigning train units from shunting yards to scheduled train services in such a way that the resulting operations are without conflicts. The problem arises at every...... shunting yard in the railway network and involves matching train units to arriving and departing train services as well as assigning the selected matchings to appropriate shunting yard tracks. We present an extensive comparison benchmark of multiple solution approaches for this problem, some of which...... are novel. In particular, we develop a constraint programming formulation, a column generation approach, and a randomized greedy heuristic. We compare and benchmark these approaches with two existing methods, a mixed integer linear program and a two-stage heuristic. The benchmark contains multiple real...

  5. Epidural haematoma: pathophysiological significance of extravasation and arteriovenous shunting

    International Nuclear Information System (INIS)

    Habash, A.H.; Sortland, O.; Zwetnow, N.N.

    1982-01-01

    35 patients with epidural bleeding operated on at Rikshospitalet, Oslo, during the period 1965 - 1980 had preoperative angiography with visualization of the external carotid artery. Twenty-one patients had extravasation of contrast medium from meningeal arteries. Seventeen of the 21 had also shunting of contrast medium from meningeal arteries to meningeal or diploic veins, while 20 of the 21 also had bled from a ruptured meningeal artery at operation. It was further found that of 20 patients who deteriorated after trauma 18 had an epidural arteriovenous shunt or extravasation. Conversely, of 15 patients who improved after trauma 12 had no evidence of a shunt. The strong correlation between the clinical course and the occurrence of extravasation supports previous experimental and clinical data, indicating the epidural arteriovenous shunt to be a major factor in the pathophysiology and the outcome of epidural bleeding. (author)

  6. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  7. Ahmed Glaucoma Valve Implantation for Uveitic Glaucoma Secondary to Behçet Disease.

    Science.gov (United States)

    Satana, Banu; Yalvac, Ilgaz S; Sungur, Gulten; Eksioglu, Umit; Basarir, Berna; Altan, Cigdem; Duman, Sunay

    2015-01-01

    To evaluate outcomes of patients with uveitic glaucoma secondary to Behçet disease (BD) who underwent Ahmed glaucoma valve (AGV) implantation. A retrospective chart review of 14 eyes of 10 patients with uveitic glaucoma associated with BD who underwent AGV implantation at a tertiary referral center. Treatment success was defined as intraocular pressure (IOP) between 6 and 21 mm Hg with or without antiglaucoma medication, without further additional glaucoma surgery or loss of light perception. The main outcome measures were IOP, best-corrected visual acuity measured with Snellen charts, and number of glaucoma medications. Mean duration of postoperative follow-up was 18.2±6.6 months (range, 6 to 31 mo). Of the 14 eyes, 10 (71.4%) were pseudophakic and 5 (35.7%) had primary AGV implantation without a history of previous glaucoma surgery. At the most recent follow-up visit, 13 of the 14 eyes had an IOP between 6 and 21 mm Hg. Mean IOP was significantly reduced during follow-up, as compared with preoperative values (P≤0.005). The cumulative probability of surgical success rate was 90.9% at 18 months based on Kaplan-Meier survival analysis. The mean number of antiglaucoma medications required to achieve the desired IOP decreased from 3.4±0.5 preoperatively to 1.0±1.1 postoperatively (P≤0.05). Visual acuity loss of >2 lines occurred in 4 eyes (28.5%) due to optic atrophy associated with retinal vasculitis. Temporary hypotony developed during follow-up in 4 eyes (28.5%) at first postoperative week. For the management of uveitic glaucoma associated with BD, AGV implantation is a successful method for glaucoma control but requires additional surgical interventions for high early hypotony rates.

  8. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    OpenAIRE

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Jingjing Huang,1 Jialiu Lin,1 Ziqiang Wu,2 Hongzhi Xu,3 Chengguo Zuo,1 Jian Ge1 1State Key Laboratory of Ophthalmology, Department of Glaucoma, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People’s Republic of China; 2Center for Advanced Eye Care, Carson City, NV, USA; 3Institute of Child Health Policy, University of Florida, Gainesville, FL, USA Purpose: The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve...

  9. iPad mini for dummies

    CERN Document Server

    Baig, Edward C

    2014-01-01

    Find out why the iPad mini has never been bigger This new edition of iPad mini For Dummies covers all the latest tips and tricks for getting an even bigger bang out of your iPad mini. Presented in full-color and written in the straightforward but fun language that has defined the For Dummies brand for more than twenty years, this friendly guide walks you through the multitouch interface, going online, getting connected, packing your iPad mini with apps, games, e-books, photos, music, and movies, synchronizing your data, texting with iMessage, working with Siri, importing pictures and launching

  10. Clinical outcomes of temporary shunting for infants with cerebral pseudomeningocele.

    Science.gov (United States)

    Mattei, Tobias A; Sambhara, Deepak; Bond, Brandon J; Lin, Julian

    2014-02-01

    Although in the case of subdural collections temporary shunting has been suggested as a viable alternative for definitive drainage of the accumulated fluid until restoration of the normal CSF dynamics, there is no agreement on the best management strategy for pseudomeningocele. The authors performed a retrospective chart review in order to evaluate the clinical outcomes of infants temporarily shunted for pseudomeningocele without encephalocele at our institution (The University of Illinois at Peoria/Illinois Neurological Institute) in the period from 2004 to 2012. The epidemiological characteristics, clinical management, and final outcomes of such subpopulation were compared with a control group which received temporary shunting for subdural hematomas (SDH) during the same period. Four patients (100% male) ranging in age from 8.9 to 27.1 months (mean = 13.88) with pseudomeningocele and 17 patients (64.7% male) ranging in age from 1.9 to 11.8 months (mean = 4.15) with SDH were identified. Although the initial management included sequential percutaneous subdural tapping in 82% of the patients, all children ultimately failed such strategy, requiring either subdural-peritoneal (81% of the cases) or subgaleal-peritoneal (19% of the cases) shunting. The mean implant duration was 201 days for the pseudomeningocele group and 384 days for the SDH one. Mean post-shunt hospitalization was 2 days for patients with pseudomeningocele and 4 days for patients with SDH. There was no statistical difference in terms of complications, length of hospitalization post-shunting, or clinical outcomes between the patients with pseudomeningocele and those with SDH. Temporary shunting of infants with pseudo-meningocele constitutes a viable therapeutic alternative with favorable clinical outcomes and a low risk of shunt dependency similar to those of children with SDH.

  11. Cross-species functionality of pararetroviral elements driving ribosome shunting.

    Directory of Open Access Journals (Sweden)

    Mikhail M Pooggin

    Full Text Available BACKGROUND: Cauliflower mosaic virus (CaMV and Rice tungro bacilliform virus (RTBV belong to distinct genera of pararetroviruses infecting dicot and monocot plants, respectively. In both viruses, polycistronic translation of pregenomic (pg RNA is initiated by shunting ribosomes that bypass a large region of the pgRNA leader with several short (sORFs and a stable stem-loop structure. The shunt requires translation of a 5'-proximal sORF terminating near the stem. In CaMV, mutations knocking out this sORF nearly abolish shunting and virus viability. METHODOLOGY/PRINCIPAL FINDINGS: Here we show that two distant regions of the CaMV leader that form a minimal shunt configuration comprising the sORF, a bottom part of the stem, and a shunt landing sequence can be replaced by heterologous sequences that form a structurally similar configuration in RTBV without any dramatic effect on shunt-mediated translation and CaMV infectivity. The CaMV-RTBV chimeric leader sequence was largely stable over five viral passages in turnip plants: a few alterations that did eventually occur in the virus progenies are indicative of fine tuning of the chimeric sequence during adaptation to a new host. CONCLUSIONS/SIGNIFICANCE: Our findings demonstrate cross-species functionality of pararetroviral cis-elements driving ribosome shunting and evolutionary conservation of the shunt mechanism. We are grateful to Matthias Müller and Sandra Pauli for technical assistance. This work was initiated at Friedrich Miescher Institute (Basel, Switzerland. We thank Prof. Thomas Boller for hosting the group at the Institute of Botany.

  12. Treatment of Hydrocephalus Associated with Neurosarcoidosis by Multiple Shunt Placement

    OpenAIRE

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-01-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showe...

  13. Transluminal angioplasty of a stenotic surgical splenorenal shunt

    International Nuclear Information System (INIS)

    Beers, B. van; Roche, A.; Cauquil, P.

    1988-01-01

    A stenosis of a side-to-side splenorenal shunt was treated by percutaneous angioplasty two years after the performance of the shunt. After dilatation, there was a fall of the splenorenal pressure gradient from 28 to 17 cm H 2 O and good transanastomotic flow was re-estabilshed. As in other arterial and venous territories, angioplasty may be an interesting alternative to surgery. (orig.)

  14. The East London glaucoma prediction score: web-based validation of glaucoma risk screening tool

    Science.gov (United States)

    Stephen, Cook; Benjamin, Longo-Mbenza

    2013-01-01

    AIM It is difficult for Optometrists and General Practitioners to know which patients are at risk. The East London glaucoma prediction score (ELGPS) is a web based risk calculator that has been developed to determine Glaucoma risk at the time of screening. Multiple risk factors that are available in a low tech environment are assessed to provide a risk assessment. This is extremely useful in settings where access to specialist care is difficult. Use of the calculator is educational. It is a free web based service. Data capture is user specific. METHOD The scoring system is a web based questionnaire that captures and subsequently calculates the relative risk for the presence of Glaucoma at the time of screening. Three categories of patient are described: Unlikely to have Glaucoma; Glaucoma Suspect and Glaucoma. A case review methodology of patients with known diagnosis is employed to validate the calculator risk assessment. RESULTS Data from the patient records of 400 patients with an established diagnosis has been captured and used to validate the screening tool. The website reports that the calculated diagnosis correlates with the actual diagnosis 82% of the time. Biostatistics analysis showed: Sensitivity = 88%; Positive predictive value = 97%; Specificity = 75%. CONCLUSION Analysis of the first 400 patients validates the web based screening tool as being a good method of screening for the at risk population. The validation is ongoing. The web based format will allow a more widespread recruitment for different geographic, population and personnel variables. PMID:23550097

  15. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma.

    Science.gov (United States)

    Angmo, Dewang; Sharma, Reetika; Temkar, Shreyas; Dada, Tanuj

    2015-05-01

    ExPress glaucoma filtration device (GFD) has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs) not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications) was achieved in eight cases (66.7%) and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications) in two cases (16.7%) at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37). ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma's, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  16. Assessment Lumboperitoneal or Ventriculoperitoneal Shunt Patency by Radionuclide Technique: A Review Experience Cases

    International Nuclear Information System (INIS)

    Chiewvit, Sunanta; Nuntaaree, Sarun; Kanchaanapiboon, Potjanee; Chiewvit, Pipat

    2014-01-01

    Hydrocephalus-related symptoms that worsen after shunt placement may indicate a malfunctioning or obstructed shunt. The assessment of shunt patency and site of obstruction is important for planning of treatment. The radionuclide cerebrospinal fluid (CSF) shunt study provides a simple, effective, and low-radiation-dose method of assessing CSF shunt patency. The radionuclide CSF shuntography is a useful tool in the management of patients presenting with shunt-related problems not elucidated by conventional radiological examination. This article described the imaging technique of ventriculoperitoneal (VP) shunt and lumbar puncture (LP) shunt. The normal finding, abnormal finding of completed obstruction and partial obstruction is present by our cases experience. The radiopharmaceutical (Tc-99m diethylenetriaminepentaacetic acid) was injected via the reservoir for VP shunt and via lumbar puncture needle in subarachnoid space for LP shunt, then serial image in the head and abdominal area. The normal function of VP and LP shunt usually rapid spillage of the radioactivity in the abdominal cavity diffusely. The patent proximal tube VP shunt demonstrates ventricular reflux. The early image of patent LP shunt reveals no activity in the ventricular system contrast to distal LP shunt reveals early reflux of activity in the ventricular system. The completed distal VP and LP shunt obstruction show absence of tracer in the peritoneal area or markedly delayed appearance of abdominal activity. The partial distal VP and LP shunt obstruction recognized by slow transit or accumulation of tracer at the distal end or focal tracer in the peritoneal cavity near the tip of distal shunt. The images of the normal and abnormal CSF shunt as describe before are present in the full paper. Radionuclide CSF shuntography is a reliable and simple procedure for assessment shunt patency

  17. Teach yourself visually Mac Mini

    CERN Document Server

    Hart-Davis, Guy

    2012-01-01

    The perfect how-to guide for visual learners Apple?s Mac Mini packs a powerful punch is in a small package, including both HDMI and Thunderbolt ports plus the acclaimed OS X. But if you want to get the very most from all this power and versatility, be sure to get this practical visual guide. With full-color, step-by-step instructions as well as screenshots and illustrations on every page, it clearly shows you how to accomplish tasks rather than burying you in pages of text. Discover helpful visuals and how-tos on the OS, hardware specs, Launchpad, the App Store, multimedia capabilities (such

  18. Glaucoma: a brief update for 2017

    African Journals Online (AJOL)

    Abstract. Glaucoma is a complex condition of the eye and the second leading cause of blindness around the globe. It is an ... to a disease, trauma or drugs, or as being congenital in nature ..... as dry eyes, blurred vision, blepharitis and others.

  19. THE PRACTICAL SIGNIFICANCE OF GLAUCOMA INVESTIGATIONS

    African Journals Online (AJOL)

    more reliable and the more practical ones in a short, concise manner ... pathological changes in the affected eye'" This definition makes it clear ... having glaucoma; clear-cut clinical cases are excluded. So often ... be remembered that the provocative tests are helpful, but ... Make sure your Schiotz tonometer is standardized.

  20. Methylphenidate (Ritalin-associated Cataract and Glaucoma

    Directory of Open Access Journals (Sweden)

    Chao-Kung Lu

    2006-12-01

    Full Text Available Methylphenidate hydrochloride (Ritalin is the drug of choice for attention deficit hyperactivity disorder (ADHD. However, an association of Ritalin with glaucoma has been reported. We report a case of Ritalin-associated cataract and glaucoma. A 10-year-old boy was diagnosed with ADHD and had received methylphenidate hydrochloride, 60 mg/day for 2 years. He presented with blurred vision. Best-corrected visual acuity was 6/60 in both eyes. Ocular examinations revealed intraocular pressure (IOP of 30 mmHg under medication, dense posterior subcapsular opacity of lens, pale disc with advanced cupping, and marked constriction of visual field. Despite maximal anti-glaucomatous medication, IOP still could not be controlled. The patient then received combined cataract and glaucoma surgery. Visual acuity improved and IOP was within normal limits in both eyes postoperatively. Large dose of methylphenidate may cause cataract and glaucoma. The mechanism remains unclear. Doctors should be aware of the possible ocular side effects of methylphenidate.

  1. Molteno3 Implantation as Primary Glaucoma Surgery

    Directory of Open Access Journals (Sweden)

    Juha O. Välimäki

    2014-01-01

    Full Text Available Purpose. To determine the outcome of Molteno3 implantation as primary glaucoma surgery and to analyze the factors influencing the surgical outcome. Methods. This is a retrospective clinical study of 106 consecutive eyes (97 patients with no previous glaucoma surgery. Surgical failure was defined as an IOP > 21 mmHg or less than a 20% reduction below baseline, or IOP ≤ 5 mmHg, on two consecutive visits after 3 months follow-up, or reoperation for glaucoma or loss of light perception. Results. At the end of the follow-up (mean, 35 months; range, 12–71 months, the mean postoperative IOP (14.2 ± 4.4 mmHg was statistically significantly lower than the preoperative IOP (35.2 ± 9.7 mmHg (P<0.001. Life-table success rates were 97%, 94%, and 91% after follow-up of 12, 24, and 36 months, respectively. Success rate for an IOP ≤ 18 mmHg was 77% at the last visit. Success was not influenced by previous cataract surgery, sex, age, laser trabeculoplasty (LTP, preoperative IOP, or number of antiglaucoma medications. Forty-seven eyes had 66 postoperative complications. Conclusions. The primary Molteno3 implant provided significant IOP lowering with minimal and manageable complications in uncontrolled glaucoma. Neither previous cataract surgery nor LTP had any detrimental effect on surgical success.

  2. Glaucoma facomórfico y ultrabiomicroscopia

    Directory of Open Access Journals (Sweden)

    María Cristina González González

    2015-01-01

    Conclusiones: La ultrabiomicroscopia es un herramienta útil ya que permite una valoración completa del segmento anterior, aun en presencia de medios opacos y ayuda a determinar la relación del cristalino con las estructuras adyacentes y el probable mecanismo del glaucoma.

  3. Alzheimer's disease pathology and shunt surgery outcome in normal pressure hydrocephalus.

    Directory of Open Access Journals (Sweden)

    Sevil Yasar

    Full Text Available We aimed to determine whether presence of AD neuropathology predicted cognitive, gait and balance measures in patients with idiopathic normal pressure hydrocephalus (iNPH after shunt surgery. This is a prospective study of gait and balance measured by Timed Up and Go (TUG and Tinetti tests, and cognitive function measured by Mini Mental Status Exam (MMSE, before and after shunt surgery in participants 65 years and older with iNPH at the Johns Hopkins University. Random effects models were used and adjusted for confounders. 88 participants were included in the analysis with a median (IQR time of 104 (57-213 days between surgery and follow-up. 23 (25% participants had neuritic plaques present (NP+ and were significantly older [76.4 (6.0 years], but were otherwise similar in all demographics and outcome measures, when compared to the group without neuritic plaques (NP-. NP- and NP+ participants equally improved on measures of TUG (β = -3.27, 95% CI -6.24, -0.30, p = 0.03; β = -2.37, 95% CI -3.90, -0.86, p = 0.02, respectively, Tinetti-total (β = 1.95, 95% CI 1.11, 2.78, p<0.001; β = 1.72, 95% CI 0.90, 2.53, p<0.001, respectively, -balance (β = 0.81, 95% CI 0.23, 1.38, p = 0.006; β = 0.87, 95% CI 0.40, 1.34, p<0.001, respectively and -gait (β = 1.03, 95% CI 0.61, 1.45, p<0.001; β = 0.84, 95% CI 0.16, 1.53, p = 0.02, respectively, while neither NP- nor NP+ showed significant improvement on MMSE (β = 0.10, 95% CI -0.27, 0.46, p = 0.61, β = 0.41, 95% CI -0.27, 1.09, p = 0.24, respectively. In summary, 26% of participants with iNPH had coexisting AD pathology, which does not significantly influence the clinical response to shunt surgery.

  4. Childhood glaucoma surgery in the 21st Century

    Science.gov (United States)

    Papadopoulos, M; Edmunds, B; Fenerty, C; Khaw, P T

    2014-01-01

    Most children with glaucoma will require surgery in their lifetime, often in their childhood years. The surgical management of childhood glaucoma is however challenging, largely because of its greater potential for failure and complications as compared with surgery in adults. The available surgical repertoire for childhood glaucoma has remained relatively unchanged for many years with most progress owing to modifications to existing surgery. Although the surgical approach to childhood glaucoma varies around the world, angle surgery remains the preferred initial surgery for primary congenital glaucoma and a major advance has been the concept of incising the whole of the angle (circumferential trabeculotomy). Simple modifications to the trabeculectomy technique have been shown to considerably minimise complications. Glaucoma drainage devices maintain a vital role for certain types of glaucoma including those refractory to other surgery. Cyclodestruction continues to have a role mainly for patients following failed drainage/filtering surgery. Although the prognosis for childhood glaucoma has improved significantly since the introduction of angle surgery, there is still considerable progress to be made to ensure a sighted lifetime for children with glaucoma all over the world. Collaborative approaches to researching and delivering this care are required, and this paper highlights the need for more high-quality prospective surgical trials in the management of the childhood glaucoma. PMID:24924446

  5. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  6. Update on pigment dispersion syndrome and pigmentary glaucoma.

    Science.gov (United States)

    Okafor, Kingsley; Vinod, Kateki; Gedde, Steven J

    2017-03-01

    The present article reviews the clinical features and pathogenesis of pigment dispersion syndrome and pigmentary glaucoma and provides an update regarding their diagnosis and management. Newer imaging modalities including ultrasound biomicroscopy and anterior segment optical coherence tomography facilitate visualization of the iris concavity characteristic of eyes with pigment dispersion syndrome and pigmentary glaucoma. Patients with pigmentary glaucoma may be distinguished from those with other glaucoma types by the presence of typical symptoms, personality type, and patterns of diurnal intraocular pressure fluctuation. Although laser iridotomy has been shown to alter iris anatomy in pigmentary glaucoma, it is not proven to slow visual field progression. Multiple trials have validated the safety and efficacy of filtering surgery in treating pigmentary glaucoma, with fewer studies published on the role of micro-invasive glaucoma surgery. Literature from the review period has further defined the unique clinical characteristics of pigment dispersion syndrome and pigmentary glaucoma. Laser surgery has a limited role in the management of these entities, whereas trabeculectomy remains an acceptable first-line surgical treatment. Further studies are needed to define the potential application of the newer micro-invasive glaucoma procedures in pigmentary glaucoma.

  7. Avaliação dos tipos de glaucoma no serviço de oftalmologia da UNICAMP Evaluation of glaucoma types at the sector of ophthalmology - UNICAMP

    Directory of Open Access Journals (Sweden)

    Andréia Peltier Urbano

    2003-01-01

    Full Text Available OBJETIVO: Avaliar a freqüência dos tipos de glaucoma no Setor de Glaucoma do Hospital das Clínicas da Universidade Estadual de Campinas. MÉTODOS: Estudo transversal de 329 pacientes atendidos no Setor de Glaucoma da Universidade Estadual de Campinas entre 1 de outubro e 20 de dezembro de 2000, com avaliação dos tipos de glaucoma e conduta terapêutica. RESULTADOS: De 329 pacientes atendidos no Ambulatório de Glaucoma, 132 foram encaminhados ao ambulatório por suspeita de glaucoma (40,1% e 197 como glaucoma diagnosticado (59,9%. Dos 132 suspeitos de glaucoma, 90 (68,2% foram confirmados como tendo glaucoma e 42 (31,8% encontram-se em acompanhamento. Dos 329 pacientes avaliados, 283 (86% tinham glaucoma, 42 (12,8% suspeita de glaucoma, 2 (0,6% diagnóstico de glaucoma excluído e 2 (0,6% hipertensão ocular. Dos 530 olhos glaucomatosos, havia 298 (56,2% glaucomas primários de ângulo aberto, 108 (20,4% glaucomas primários de ângulo estreito, 21 (4% glaucomas pós-facectomia, 19 (3,6% glaucomas congênitos e 16 (3% glaucomas de pressão normal. A conduta terapêutica adotada foi inicialmente clínica em todos os casos. Após seguimento médio de 10,5 meses, 89 (16,8% olhos necessitaram tratamento com laser: 72 (13,6% iridotomias, 7 (1,3% trabeculoplastias e 10 (1,9% panfotocoagulações. Cento e setenta e cinco olhos (33% foram submetidos a tratamento cirúrgico. CONCLUSÃO: O tipo mais freqüente de glaucoma observado foi o glaucoma primário de ângulo aberto, seguido por glaucoma primário de ângulo estreito. Glaucomas como o de pressão normal e o pseudo-exfoliativo foram pouco freqüentes na população estudada.PURPOSE: To evaluate the frequency of different types of glaucoma at the Hospital das Clínicas of Campinas State University. METHODS: Cross-sectional study of 329 patients followed at the Glaucoma Service of Campinas State University from October 1 to December 20, 2000. The frequency of each type of glaucoma and the

  8. Programmable shunts and headphones: Are they safe together?

    Science.gov (United States)

    Spader, Heather S; Ratanaprasatporn, Linda; Morrison, John F; Grossberg, Jonathan A; Cosgrove, G Rees

    2015-10-01

    Programmable shunts have a valuable role in the treatment of patients with hydrocephalus, but because a magnet is used to change valve settings, interactions with external magnets may reprogram these shunts. Previous studies have demonstrated the ability of magnetic toys and iPads to erroneously reprogram shunts. Headphones are even more ubiquitous, and they contain an electromagnet for sound projection that sits on the head very close to the shunt valve. This study is the first to look at the magnetic field emissions of headphones and their effect on reprogrammable shunt valves to ascertain whether headphones are safe for patients with these shunts to wear. In this in vitro study of the magnetic properties of headphones and their interactions with 3 different programmable shunts, the authors evaluated Apple earbuds, Beats by Dr. Dre, and Bose QuietComfort Acoustic Noise Cancelling headphones. Each headphone was tested for electromagnetic field emissions using a direct current gaussmeter. The following valves were evaluated: Codman Hakim programmable valve, Medtronic Strata II valve, and Aesculap proGAV. Each valve was tested at distances of 0 to 50 mm (in 5-mm increments) from each headphone. The exposure time at each distance was 1 minute, and 3 trials were performed to confirm results at each valve setting and distance. All 3 headphones generated magnetic fields greater than the respective shunt manufacturer's recommended strength of exposure, but these fields did not persist beyond 5 mm. By 2 cm, the fields levels were below 20 G, well below the Medtronic recommendation of 90 G and the Codman recommendation of 80 G. Because the mechanism for the proGAV is different, there is no recommended gauss level. There was no change in gauss-level emissions by the headphones with changes in frequency and amplitude. Both the Strata and Codman-Hakim valves were reprogrammed by direct contact (distance 0 mm) with the Bose headphones. When a rotation component was added, all

  9. MiniBooNE Oscillation Results

    International Nuclear Information System (INIS)

    Djurcic, Zelimir

    2009-01-01

    These proceedings summarize the MiniBooNE ν μ → ν e results, describe the first (bar ν) μ → (bar ν) e result, and current analysis effort with the NuMI neutrinos detected in the miniBooNE detector

  10. Design guidelines for mini-roundabouts

    CSIR Research Space (South Africa)

    Emslie, I

    1997-03-01

    Full Text Available Guidelines for Traffic Calming. Concepts and principles relating to the use of mini-roundabouts as a form of intersection control and in the traffic calming context are discussed. Warrants for the implementation of mini-roundabouts and design standards...

  11. Mini lathe machine converted to CNC

    Directory of Open Access Journals (Sweden)

    Alexandru Morar

    2012-06-01

    Full Text Available This paper presents the adaptation of a mechanical mini-lathing machine to a computerized numerical control (CNC lathing machine. This machine is composed of a ASIST mini-lathe and a two-degrees-of-freedom XZ stage designed specifically for this application. The whole system is controlled from a PC using adequate CNC control software.

  12. Glaucoma and cataract surgery: two roads merging into one.

    Science.gov (United States)

    Shah, Manjool; Law, Geoffrey; Ahmed, Iqbal Ike K

    2016-01-01

    To discuss the increasing utilization of cataract extraction in the management of glaucoma and to highlight advances in surgical care that can promote synergistic treatment of these comorbid conditions. Recent years have demonstrated significant advances in the management of glaucoma through the use of novel microinvasive glaucoma devices. Furthermore, an increased understanding of the role of cataract surgery in the treatment of various glaucomas warrants review. Nevertheless, cataract surgery in the glaucoma patient warrants specific preoperative, intraoperative, and postoperative planning to optimize visual function and quality of life while mitigating potential risk factors for adverse events. Although the challenges of performing cataract extraction on glaucoma patients exist, the potential benefit to these patients is substantial. With attention to pre- and perioperative surgical planning and intraoperative technique, as well as with awareness and potential utilization of novel devices and treatment strategies, cataract extraction offers a unique platform for anatomical and functional improvement in this increasingly common cohort of patients.

  13. Alternative therapy in glaucoma management: Is there any role?

    Directory of Open Access Journals (Sweden)

    Parikh Rajul

    2011-12-01

    Full Text Available Glaucoma is one of the leading causes of blindness worldwide. Various randomized controlled clinical trials have shown that lowering intraocular pressure (IOP does reduce progression of primary open-angle glaucoma. However, there is lots of interest in nonpharmacological options that includes lifestyle adjustment and alternative and complementary therapy (ACT. At least 5% glaucoma population uses ACT. Various lifestyle activities like exercise and alcohol can reduce IOP by 1 to 2 mm Hg but would have small effect on glaucoma. The psychological stress can increase IOP. Hypothetically and few studies do show neuroprotective effect (or effect on ocular blood flow of alcohol, Gingko biloba, bilberry, but the current evidence is weak for its routine use. We must also remember the side effects of ′medications′ (e.g., marijuana, alcohol before promoting as remedy for glaucoma. In current armamentarium of glaucoma management, ACT cannot substitute the conventional treatment available to lower IOP.

  14. Cyclo-photocoagulation in the management of aphakic glaucoma

    International Nuclear Information System (INIS)

    Lee, P.-F.

    1984-01-01

    Transpupillary argon laser photocoagulation of the ciliary processes (TALC) through a widely dilated pupil, with or without cerebral depression, has been used in the management of glaucoma in aphakic eyes for a number of years. 58% of glaucoma in aphakics treated with TALC showed sustained and meaningful intraocular pressure reduction 2 months to 5 years after the procedure. Clinically, the TALC procedure is a relatively safe, effective, and an useful alternative approach in the management of selected cases of glaucoma in aphakics. (Auth.)

  15. Superior versus inferior Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi

    2009-02-01

    To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5glaucoma surgery, phthisis bulbi, or loss of light perception. Of a total of 106 eyes, 58 and 48 eyes underwent AGV implantation in the superior and inferior quadrants, respectively. Baseline characteristics were comparable in the study groups, except for preoperative IOP, which was higher in the superior group (P = 0.01). Patients were followed for a mean period of 10.6+/-8.49 months and 10.58+/-6.75 months in the superior and inferior groups, respectively (P = 0.477). BCVA was comparable between the groups at all postoperative visits (P>0.122). After 1 year, statistically significant but comparable IOP reduction from baseline (Pglaucoma medications was comparable after 1 year (1.3+/-1.2 vs. 1.9+/-0.8 for superior and inferior implants, respectively, P = 0.256). Success rates were also similar at 1 year: 27 eyes (81.8%) versus 20 eyes (95.2%) for superior and inferior implants, respectively (P = 0.227). However, the overall rate of complications, such as implant exposure necessitating removal, cosmetically unappealing appearance, and endophthalmitis, was higher in the inferior group: 12 eyes (25%) versus 3 eyes (5.2%) for superior and inferior groups, respectively, (P = 0.004). Superior and inferior AGV implants have similar intermediate efficacy in terms of IOP reduction, decrease in number of glaucoma medications, and preservation of vision. However

  16. Outcomes of systemic to pulmonary artery shunts in patients weighing less than 3 kg: analysis of shunt type, size, and surgical approach.

    Science.gov (United States)

    Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K

    2014-02-01

    To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Evaluation of ExPress glaucoma filtration device in Indian patients with advanced glaucoma

    Directory of Open Access Journals (Sweden)

    Dewang Angmo

    2015-01-01

    Full Text Available ExPress glaucoma filtration device (GFD has recently become available in India as a surgical option for glaucoma patients. We retrospectively evaluated the outcome of ExPress GFD in 12 eyes with advanced glaucoma with intraocular pressures (IOPs not controlled on maximal tolerable medical therapy. The mean preoperative IOP of 29.58 ± 7.13 mmHg decreased to 17.0 ± 2.67 and 17.40 ± 0.89 mmHg at 6 and 12 months after surgery. Absolute success (IOP ≤ 18 mmHg, with no additional glaucoma medications was achieved in eight cases (66.7% and qualified success (IOP ≤ 18 mmHg, with additional glaucoma medications in two cases (16.7% at 1-year after surgery. Early intervention was needed in 4 patients; two underwent anterior chamber reformation while the other two required needling. Two patients required resurgery. There was no significant change in the best corrected visual acuity postoperatively (P = 0.37. ExPress GFD does not seem to offer a benefit over standard trabeculectomy in patients with advanced glaucomatous disease in terms of IOP control or complication rate. However, due to the small sample size with a heterogeneous mixture of primary and secondary glaucoma′s, we await further studies with a larger sample size and long-term follow-up, to see how the device performs.

  18. Combined Phacoemulsification and Ahmed Glaucoma Drainage Implant Surgery for Patients With Refractory Glaucoma and Cataract.

    Science.gov (United States)

    Valenzuela, Felipe; Browne, Andrew; Srur, Miguel; Nieme, Carlos; Zanolli, Mario; López-Solís, Remigio; Traipe, Leonidas

    2016-02-01

    To examine the indications, safety, efficacy, and complications of combined phacoemulsification and Ahmed glaucoma drainage implant surgery. A retrospective case review of 35 eyes (31 patients) subjected to combined phacoemulsification and Ahmed glaucoma drainage implant surgery. Demographic characteristics of the study population, indications for combined surgery, and operative and postoperative complications were recorded. Visual acuity, intraocular pressure (IOP), and number of glaucoma medications were evaluated preoperatively and postoperatively. Complete success was defined as IOP ≤ 21 mm Hg without medication, qualified success if IOP ≤ 21 mm Hg with ≥ 1 medications, and failure if IOP>21 mm Hg or ≤ 5 mm Hg on ≥ 2 consecutive visits. Mean follow-up was 29.5 months (range, 6 to 87 mo). The most common indication for combined surgery was a history of prior failed trabeculectomy (60%). Postoperative visual acuity improved in 30 of 35 eyes (85%) (PAhmed glaucoma drainage implant surgery seems to be a safe and effective surgical option, providing good visual rehabilitation and control of IOP for patients with refractory glaucoma and cataract.

  19. Childhood glaucoma profile in Dakahelia, Egypt: a retrospective study

    Directory of Open Access Journals (Sweden)

    Tharwat H. Mokbel

    2018-04-01

    Full Text Available AIM: To analyze childhood glaucoma regarding its demographics, presentations, different causes and surgical modalities used among patients in Dakahelia and to apply the Childhood Glaucoma Research Network (CGRN classification retrospectively to evaluate its convenience. METHODS: A retrospective study in which the medical files of all glaucoma patients <16 years old presented to Mansoura Ophthalmic Center, Mansoura University from 2014 to 2017, were retrieved and analyzed. Collected data included: age, gender, laterality, visual acuity (VA, refraction, intraocular pressure (IOP, corneal diameter, cup-disc ratio, types and number of surgeries and antiglaucomatous drugs (AGD at the first and last visit. Prevalence of different subtypes was calculated and means of clinical features were compared. RESULTS: A total of 305 eyes of 207 patients were included classified into 6 groups: primary congenital glaucoma (PCG, juvenile open angle glaucoma (JOAG, glaucoma associated with systemic disease, glaucoma associated with ocular anomalies, acquired glaucoma and glaucoma following cataract surgery. PCG was the predominant type (55.1% followed by acquired glaucoma (29.5%. Males represented 63.8% of the whole studied patients. Glaucoma associated with ocular anomaly group showed the youngest age at diagnosis (21.9±30.0mo. The shortest corneal diameter was recorded in post cataract group (10.4±0.5 mm. Highest cup-disc ratio was found in the PCG group (P<0.0005. Glaucoma associated with systemic disease presented with the highest baseline IOP (34.5±5.0 mm Hg. All the cases with PCG were treated surgically with 21.8% required more than one surgery. The majority of the patients (74.2% in the acquired group were treated medically. Combined trabeculotomy-trabeculectomy was the most frequent operation done, accounting for 34.5% of all primary surgeries. Ahmed valve implantation comprised 87% of the secondary surgeries. Acquired glaucoma group had the highest

  20. Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Razeghinejad

    2016-09-01

    Full Text Available Glaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum tolerable medications. Details of the glaucoma surgical management of these patients as well as their postoperative care and pregnancy and clinical outcomes on longitudinal follow-up are discussed. All 3 patients had juvenile open-angle glaucoma and were on various anti-glaucoma medications, including oral acetazolamide. The first case described underwent trabeculectomy without antimetabolites in both eyes because of uncontrolled intraocular pressure with topical medications. The surgery was done with topical lidocaine jelly and subconjunctival lidocaine during the second and third trimesters. The second patient had an Ahmed valve implantation in both eyes during the second and third trimesters because of uncontrolled IOP with topical medications and no response to selective laser trabeculoplasty. Surgery was done with topical tetracaine and subconjunctival and sub-Tenon’s lidocaine. The third case had a Baerveldt valve implantation under general anesthesia in the second trimester. In selected pregnant glaucoma patients with medically uncontrolled intraocular pressure threatening vision, incisional surgery may lead to good outcomes for the patient with no risk for the fetus.

  1. Relationship between retinal lattice degeneration and open angle glaucoma.

    Science.gov (United States)

    Rahimi, Mansour

    2005-01-01

    Patients with retinal disorders may develop glaucoma of both a primary and secondary type. Pigment may contribute to trabecular obstruction in some patients with open-angle glaucoma. Lattice degeneration of the retina in its typical form is a sharply demarcated, circumferentially oriented, degenerative process with significant alterations of retinal pigmentation. The association between myopia, open angle glaucoma and pigment dispersion is striking. Therefore, it could be postulated that there is significant prevalence of open angle glaucoma in patients with retinal lattice degeneration, especially in combination with myopia.

  2. Pigment dispersion syndrome and pigmentary glaucoma--a major review.

    Science.gov (United States)

    Niyadurupola, Nuwan; Broadway, David C

    2008-12-01

    Pigment dispersion syndrome (PDS) is an interesting condition that can lead to secondary open angle glaucoma. Pigmentary glaucoma is primarily a disease of young people, myopes and men. PDS is characterized by the presence of Krukenberg spindles, iris trans-illumination defects, trabecular meshwork pigmentation and backward bowing of the iris. Posterior bowing of the iris causes rubbing of the pigmented iris epithelium against lens structures, liberation of pigment and trabecular meshwork changes that result in reduced aqueous outflow with the risk of glaucoma. Peripheral laser iridotomy can reverse backward bowing of the iris and may prevent progression of pigmentary glaucoma.

  3. Short-term outcomes after EX-PRESS implantation versus trabeculectomy alone in patients with neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Shinohara Y

    2017-12-01

    Full Text Available Yoichiro Shinohara, Hideo Akiyama, Mikiya Magori, Shoji Kishi Department of Ophthalmology, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan Background: The purpose of this study was to investigate postoperative clinical outcomes in patients with neovascular glaucoma (NVG who underwent trabeculectomy or EX-PRESS implantation and to identify predictors of successful EX-PRESS implantation. Methods: The study designed as a retrospective observational analysis and was set in a single tertiary center. Eighty-nine patients (89 eyes with NVG, were treated using trabeculectomy alone (Trab group; n=39 or EX-PRESS implantation (EX group; n=50. All patients with a history of glaucoma surgery were excluded. The main outcome measures were postoperative intraocular pressure (IOP, visual acuity (VA, number of medications, complications, additional therapy, and success rate. Results: The mean follow-up duration was 4.6 months in the Trab group and 4.2 months in the EX group. There was no significant difference in IOP between the groups except at 1-month follow-up (P=0.045. The number of patients with early postoperative hypotony, a shallow anterior chamber, hyphema, or anterior chamber irrigation was significantly lower in the EX group than in the Trab group (P=0.016, 0.008, 0.019, and 0.014, respectively. The other outcomes, ie, VA, number of medications, and success rate, were similar between the two groups. In the EX group, the success rate was significantly lower in 15 patients with a history of vitrectomy compared to that in 35 patients without a history of vitrectomy (P=0.047. Conclusion: Implantation of an EX-PRESS device may be more effective and safer than trabeculectomy alone in patients with NVG. However, a history of vitrectomy may affect the surgical success rate when using EX-PRESS. Keywords: trabeculectomy, EX-PRESS, neovascular glaucoma, surgery, tube shunt

  4. A Modified Shunt System for the Management of Pyogenic Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Abdul Naveed Khan

    2017-01-01

    Full Text Available BACKGROUND: To describe the structure and efficacy of a modified cerebrospinal fluid (CSF shunt system with Bhatti CSF access chamber and ventriculoperitoneal shunt, for the management of hydrocephalus associated with pyogenic ventriculitis. METHODS: This was an observational study performed at the National Medical Center and Ziauddin Medical University, Karachi, Pakistan. Chemically bonded Bhatti CSF access chamber and ventriculoperitoneal shunt was inserted into 443 patients with hydrocephalus and pyogenic ventriculitis to allow injection of antibiotics into the lateral ventricles. RESULTS: In all patients, symptoms and signs of hydrocephalus were relieved immediately after shunt insertion and infection brought under control within two weeks of intraventricular injection of antibiotics (vancomycin or linezolid, via the CSF access chamber. In two patients peritoneal catheter was blocked by a precipitate of vancomycin. Reduction in the dose of intraventricular vancomycin from 50mg to 20mg and increased dilution (additional 2ml of 0.9% N/S solution prevented recurrence of this complication. All patients recovered from ventriculitis within two weeks of initiating this treatment. Follow-up was from 3 months to 2 years to monitor continued relief of hydrocephalus and absence of recurrence of ventriculitis. CONCLUSION: Bhatti CSF access chamber and the ventriculoperitoneal shunt is the only system available at present that fulfills the management of hydrocephalus associated with pyogenic ventriculitis. It provides continuous internal drainage of CSF combined with access to the ventricles for injection of antibiotics.

  5. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey

    Directory of Open Access Journals (Sweden)

    Daniel E. Grigera

    2013-06-01

    Full Text Available PURPOSE: The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. METHODS: An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1 and diagnosis (Part 2 of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. RESULTS: Fifty participants from 14 countries completed the questionnaire. For the medical treatment of glaucoma, nearly all respondents (98% or greater confirmed that medical treatment as first-line therapy is preferred to surgery, prostaglandin analogs are the medication of first choice for primary open-angle glaucoma (POAG, longitudinal monitoring of efficacy should include intraocular pressure, structural and functional status, as well as if patients' quality of life is impaired by the high cost of medication. For the diagnosis of glaucoma section, all respondents confirmed that, after initial examination, gonioscopy should be repeated over time, standard automated perimetry is the most important functional examination for diagnosis and monitoring of primary open-angle glaucoma, central corneal thickness is important in assessment of glaucoma, and computerized imaging tests help in clinical evaluation of optic disc. CONCLUSIONS: This survey shows a high level of agreement on most aspects of glaucoma diagnosis and treatment among Latin American glaucoma experts. Areas of disagreement highlight the need for further evidence or education. These findings will be useful for guiding future efforts to optimize glaucoma practice by clinicians in Latin America.

  6. Level of agreement among Latin American glaucoma subspecialists on the diagnosis and treatment of glaucoma: results of an online survey.

    Science.gov (United States)

    Grigera, Daniel E; Mello, Paulo Augusto Arruda; Barbosa, Wilma Lelis; Casiraghi, Javier Fernando; Grossmann, Rodolfo Perez; Peyret, Alejo

    2013-01-01

    The aim of this research was to assess the level of agreement among glaucoma experts in Latin America on key practices related to treatment and diagnosis of glaucoma. An online questionnaire was sent to a multinational panel of glaucoma experts. The questionnaire contained 107 statements on the medical treatment (Part 1) and diagnosis (Part 2) of glaucoma, and was developed in Spanish and translated into English. Agreement was defined as >70% of respondents. Fifty participants from 14 countries completed the questionnaire. For the medical treatment of glaucoma, nearly all respondents (98% or greater) confirmed that medical treatment as first-line therapy is preferred to surgery, prostaglandin analogs are the medication of first choice for primary open-angle glaucoma (POAG), longitudinal monitoring of efficacy should include intraocular pressure, structural and functional status, as well as if patients' quality of life is impaired by the high cost of medication. For the diagnosis of glaucoma section, all respondents confirmed that, after initial examination, gonioscopy should be repeated over time, standard automated perimetry is the most important functional examination for diagnosis and monitoring of primary open-angle glaucoma, central corneal thickness is important in assessment of glaucoma, and computerized imaging tests help in clinical evaluation of optic disc. This survey shows a high level of agreement on most aspects of glaucoma diagnosis and treatment among Latin American glaucoma experts. Areas of disagreement highlight the need for further evidence or education. These findings will be useful for guiding future efforts to optimize glaucoma practice by clinicians in Latin America.

  7. Determining the optimal portal blood volume in a shunt before surgery in extrahepatic portal hypertension

    Directory of Open Access Journals (Sweden)

    Yurchuk Vladimir A

    2016-04-01

    Full Text Available The aim of the study: To determine the necessary shunt diameter and assess the optimal portal blood volume in a shunt in children with extrahepatic portal hypertension before the portosystemic shunt surgery. Changes in the liver hemodynamics were studied in 81 children aged from 4 to 7 years with extrahepatic portal hypertension. We established that it is necessary to calculate the shunt diameter and the blood volume in a shunt in patients with extrahepatic portal hypertension before the portosystemic shunt surgery. It allows us to preserve the hepatic portal blood flow and effectively decrease the pressure in the portal system. Portosystemic shunt surgery in patients with extrahepatic portal hypertension performed in accordance with the individualized shunt volume significantly decreases portal pressure, preserves stable hepatic hemodynamics and prevents gastro-esophageal hemorrhage.

  8. Post V-P shunt surgical site EDH an uncommon complication: case report

    Directory of Open Access Journals (Sweden)

    Garg Manish

    2017-06-01

    Full Text Available ventriculoparitoneal shunt is well established modality of treatment for hydrocephalous. Complication of v-p shunt are also mentioned in literature like shunt infection shunt migration etc [8]. Here we are describing a rare complication of vp shunt which barely mentioned in literature. A 22 yr male admitted with complain of headache & vomiting patient was diagnosed to have tubercular meningities with hydrocephalous. Patient planned for ventriculoparietoneal shunt surgery and vp shunt was done. On 3rd post-surgery day patient develop weakness in Left side of body. Urgent ncct head done which showed EDH at surgical site. Immediate craniotomy and evacuation of hematoma was done patient improved and discharged. Thus we are discussing the importance of meticulous surgery for v-p shunt, post op ct scan and treatment.

  9. Pattern-reversal electroretinograms in unilateral glaucoma.

    Science.gov (United States)

    Wanger, P; Persson, H E

    1983-06-01

    Pattern-reversal and flash electroretinograms (ERG) and oscillatory potentials (OP) were recorded from 11 patients with unilateral glaucoma. All glaucomatous eyes had reduced amplitudes both compared to the opposite eye in the same patient and to reference values. In 10 of the 11 cases this reduction was below the level of normal variation. The difference in pattern-reversal ERG amplitude means from glaucomatous and opposite eyes was statistically significant. No differences were observed in flash ERGs or OPs. The histopathologic correlate to the visual field defects in glaucoma is retinal ganglion cell degeneration. The present electrophysiologic findings support the view, based on results from animal experiments, that the pattern-reversal ERG reflects ganglion cell activity.

  10. Pigmentary glaucoma accompanied by Usher syndrome.

    Science.gov (United States)

    Koucheki, Behrooz; Jalali, Kamran Hodjat

    2012-08-01

    To report a case of pigmentary glaucoma (PG) accompanied by Usher syndrome. Case report. The results were presented after standard ocular examination, visual field test, anterior segment and fundus photography, electroretinography, and otolaryngology consultation were conducted. Typical retinitis pigmentosa, flat electroretinography, congenital sensorineural hearing loss, high intraocular pressure, Krukenberg spindle, iris concavity, radial iris transillumination defect, severe pigment deposition on the trabecular meshwork, and glaucomatous optic nerve damage were indicative of PG accompanied by Usher syndrome. In some rare cases, PG may coexist with Usher syndrome. Common findings of Usher syndrome, including night blindness, impaired vision, visual field defects, and retinal changes may distract the clinician from considering the diagnosis of glaucoma. Such association should be borne in mind to make a timely diagnosis and treatment possible.

  11. Glaucoma progression detection with frequency doubling technology (FDT) compared to standard automated perimetry (SAP) in the Groningen Longitudinal Glaucoma Study.

    Science.gov (United States)

    Wesselink, Christiaan; Jansonius, Nomdo M

    2017-09-01

    To determine the usefulness of frequency doubling perimetry (FDT) for progression detection in glaucoma, compared to standard automated perimetry (SAP). Data were used from 150 eyes of 150 glaucoma patients from the Groningen Longitudinal Glaucoma Study. After baseline, SAP was performed approximately yearly; FDT every other year. First and last visit had to contain both tests. Using linear regression, progression velocities were calculated for SAP (Humphrey Field Analyzer) mean deviation (MD) and FDT MD and the number of test locations with a total deviation probability below p glaucoma progression in patients who cannot perform SAP reliably. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  12. Dynamic tube movement after reimplantation of Ahmed glaucoma valve in a child with glaucoma in aphakia

    Science.gov (United States)

    Senthil, Sirisha; Badakare, Akshay

    2014-01-01

    A 10-year-old girl underwent an Ahmed glaucoma valve (AGV) implantation as a primary procedure for glaucoma in aphakia due to congenital cataract surgery. Following an unintended accidental excision of AGV tube during bleb revision for hypertensive phase, AGV was explanted and a second AGV was implanted in the same quadrant after 2 weeks. This resulted in a rare complication of dynamic tube movement in the anterior chamber with tube corneal touch and localised corneal oedema. Excision of the offending unstable tube and placement of a paediatric AGV in a different quadrant led to resolution of this complication, stable vision and well-controlled intraocular pressure. This case highlights the possible causes of dynamic tube, related complications and its management. This case also highlights the importance of understanding the various physiological phases after glaucoma drainage device implantation and their appropriate management. PMID:24695662

  13. Hypothyroidism and Glaucoma in The United States

    Science.gov (United States)

    Kakigi, Caitlin; Kasuga, Toshimitsu; Wang, Sophia Y.; Singh, Kuldev; Hiratsuka, Yoshimune; Murakami, Akira; Lin, Shan C.

    2015-01-01

    Purpose To investigate the association between hypothyroidism and glaucomatous disease. Methods This cross-sectional study included all subjects above the age of 40 years from two nationwide surveys: the 2008 National Health Interview Survey (NHIS) as well as the 2007 and 2008 National Health and Nutrition Examination Survey (NHANES). The presence or absence of glaucoma, thyroid disease and other demographic and health-related information including comorbidities was ascertained via interview. Blood samples were collected from NHANES subjects and analyzed for thyrotropin (TSH). Results A total of 13,599 and 3,839 NHIS and NHANES participants respectively were analyzed to assess for a possible relationship between self-reported glaucoma, and self-reported hypothyroidism as well as self-reported thyroid disease. The unadjusted odds ratio (OR) for NHIS showed a significant association between self-reported glaucoma and self-reported hypothyroidism (OR 1.46, 95% confidence interval [CI] 1.07-1.99). Multivariate logistic regression analysis adjusted for age, gender, race, comorbidities, and health-related behavior, however, showed no association between self-reported glaucoma and hypothyroidism or thyroid disease in both surveys (OR 1.60, 95%CI 0.87-2.95 for NHIS; OR 1.05, 95%CI 0.59-1.88 for NHANES). Conclusion A previously reported association between hypothyroidism and glaucomatous disease was not confirmed in two large U.S. health survey populations. While such an association was noted in the univariate analysis for the NHIS survey, such a relationship was not found in the multivariate analysis after adjustment for potential confounding variables. PMID:26230664

  14. Anesthetic Preconditioning as Endogenous Neuroprotection in Glaucoma

    Directory of Open Access Journals (Sweden)

    Tsung-Han Chou

    2018-01-01

    Full Text Available Blindness in glaucoma is the result of death of Retinal Ganglion Cells (RGCs and their axons. RGC death is generally preceded by a stage of reversible dysfunction and structural remodeling. Current treatments aimed at reducing intraocular pressure (IOP are ineffective or incompletely effective in management of the disease. IOP-independent neuroprotection or neuroprotection as adjuvant to IOP lowering in glaucoma remains a challenge as effective agents without side effects have not been identified yet. We show in DBA/2J mice with spontaneous IOP elevation and glaucoma that the lifespan of functional RGCs can be extended by preconditioning RGCs with retrobulbar lidocaine in one eye at four months of age that temporary blocks RGC axonal transport. The contralateral, PBS-injected eye served as control. Lidocaine-induced impairment of axonal transport to superior colliculi was assessed by intravitreal injection of cholera toxin B. Long-term (nine months effect of lidocaine were assessed on RGC electrical responsiveness (PERG, IOP, expression of relevant protein (BDNF, TrkB, PSD95, GFAP, Synaptophysin, and GAPDH and RGC density. While lidocaine treatment did not alter the age-related increase of IOP, TrkB expression was elevated, GFAP expression was decreased, RGC survival was improved by 35%, and PERG function was preserved. Results suggest that the lifespan of functional RGCs in mouse glaucoma can be extended by preconditioning RGCs in early stages of the disease using a minimally invasive treatment with retrobulbar lidocaine, a common ophthalmologic procedure. Lidocaine is inexpensive, safe and is approved by Food and Drug Administration (FDA to be administered intravenously.

  15. Shunted-Josephson-junction model. II. The nonautonomous case

    DEFF Research Database (Denmark)

    Belykh, V. N.; Pedersen, Niels Falsig; Sørensen, O. H.

    1977-01-01

    The shunted-Josephson-junction model with a monochromatic ac current drive is discussed employing the qualitative methods of the theory of nonlinear oscillations. As in the preceding paper dealing with the autonomous junction, the model includes a phase-dependent conductance and a shunt capacitance....... The mathematical discussion makes use of the phase-space representation of the solutions to the differential equation. The behavior of the trajectories in phase space is described for different characteristic regions in parameter space and the associated features of the junction IV curve to be expected are pointed...... out. The main objective is to provide a qualitative understanding of the junction behavior, to clarify which kinds of properties may be derived from the shunted-junction model, and to specify the relative arrangement of the important domains in the parameter-space decomposition....

  16. Secondary pediatric encephalocele after ventriculosubgaleal shunting for posthemorrhagic hydrocephalus.

    Science.gov (United States)

    Seeburg, Daniel; Ahn, Edward; Huisman, Thierry

    2014-08-01

    Intraventricular hemorrhage and posthemorrhagic hydrocephalus continue to be common complications in very low-birth-weight premature infants, often requiring ventricular shunting for cerebrospinal fluid diversion. We report on two infants with posthemorrhagic hydrocephalus that developed a secondary encephalocele after ventriculosubgaleal shunting. Encephaloceles can act as a source of seizure activity and can result in various additional complications including meningitis, abscess formation, and infarction of herniated brain parenchyma. With continued improvements in neonatal intensive care, the survival of infants with significant medical comorbidities-including those that develop posthemorrhagic hydrocephalus requiring ventricular shunting-continues to increase. It is thus important for the radiologist and treating physician to be aware of this rare, potential complication. Georg Thieme Verlag KG Stuttgart · New York.

  17. Forty years of shunt surgery at Rigshospitalet, Denmark

    DEFF Research Database (Denmark)

    Mansson, Philip Kofoed; Johansson, Sofia; Ziebell, Morten

    2017-01-01

    Objective The objective of this study is to review our experience of shunt surgery by investigating 40years of development in terms of rates of revision and infection, shunt survival and risk factors. Design and participants Medical records and operative reports were reviewed retrospectively...... for all patients who underwent primary shunt surgery at our department in the years 2010 to 2012. All results were compared with a previous study from our department. A mixed population consisting of 434 patients was included. Adults (≥15years) accounted for 89.9% of all patients and the mean follow.......1-54.9). Within 4weeks postoperatively, 3.2% had an infection and overall infection rate was 5.5%. Short duration of surgery and the use of antibiotic prophylaxis were associated with a lower risk of infection. The most frequent causes of revision were valve defects (18.4%) and proximal defects or obstructions...

  18. Shunt impedance of spiral loaded resonant rf cavities

    International Nuclear Information System (INIS)

    Peebles, P.Z. Jr.; Parvarandeh, M.

    1975-01-01

    Based upon a treatment of the spiral loaded resonant radio frequency cavity as a shorted quarter-wave transmission line, a model for shunt impedance is developed. The model is applicable to loosely wound spirals in large diameter containers. Theoretical shunt impedance is given for spirals wound from tubing of circular or rectangular cross section. The former produces higher shunt impedance. Measurements made at Oak Ridge National Laboratory on 17 copper cavities are described which support the theoretical results. Theoretical results are also compared to data from twenty-three additional cavities measured at Los Alamos Scientific Laboratory. It is shown that the theoretical function forms a useful means of interpreting the quality of constructed cavities. (author)

  19. Treatment of hydrocephalus associated with neurosarcoidosis by multiple shunt placement.

    Science.gov (United States)

    Kim, Sung Hoon; Lee, Sang Weon; Sung, Soon Ki; Son, Dong Wuk

    2012-09-01

    A 31-year-old man was admitted to our hospital due to hydrocephalus with neurosarcoidosis. Ventriculo-peritoneal shunting was performed in the right lateral ventricle with intravenous methylprednisolone. Subsequently, after 4 months, additional ventriculo-peritoneal shunting in the left lateral ventricle was performed due to the enlarged left lateral ventricle and slit-like right lateral ventricle. After 6 months, he was re-admitted due to upward gaze palsy, and magnetic resonance image showed an isolated fourth ventricle with both the inlet and outlet of fourth ventricle obstructed by recurrent neurosarcoidosis. Owing to the difficulty of using an endoscope, we performed neuronavigator-guided ventriculo-peritoneal shunting via the left lateral transcerebellar approach for the treatment of the isolated fourth ventricle with intravenous methyl prednisolone. The patient was discharged with improved neurological status.

  20. Mini-implant-supported Molar Distalization

    Directory of Open Access Journals (Sweden)

    Amit Goyal

    2012-01-01

    Full Text Available Temporary anchorage devices popularly called mini-implants or miniscrews are the latest addition to an orthodontist′s armamentarium. The following case report describes the treatment of a 16-year-old girl with a pleasant profile, moderate crowding and Angle′s Class II molar relationship. Maxillary molar distalization was planned and mini-implants were used to preserve the anterior anchorage. After 13 months of treatment, Class I molar and canine relation was achieved bilaterally and there was no anterior proclination. Thus, mini-implants provide a viable option to the clinician to carry out difficult tooth movements without any side effects.

  1. The MiniBooNE detector

    International Nuclear Information System (INIS)

    Aguilar-Arevalo, A.A.; Anderson, C.E.; Bartoszek, L.M.; Bazarko, A.O.; Brice, S.J.; Brown, B.C.; Bugel, L.; Cao, J.; Coney, L.; Conrad, J.M.; Cox, D.C.; Curioni, A.; Djurcic, Z.; Finley, D.A.; Fleming, B.T.; Ford, R.; Garcia, F.G.; Garvey, G.T.; Green, C.; Green, J.A.

    2009-01-01

    The MiniBooNE neutrino detector was designed and built to look for ν μ →ν e oscillations in the (sin 2 2θ,Δm 2 ) parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  2. The MiniBooNE Detector

    OpenAIRE

    MiniBooNE Collaboration

    2008-01-01

    The MiniBooNE neutrino detector was designed and built to look for muon-neutrino to electron-neutrino oscillations in the mixing parameter space region where the LSND experiment reported a signal. The MiniBooNE experiment used a beam energy and baseline that were an order of magnitude larger than those of LSND so that the backgrounds and systematic errors would be completely different. This paper provides a detailed description of the design, function, and performance of the MiniBooNE detector.

  3. Quality Assurance Framework for Mini-Grids

    Energy Technology Data Exchange (ETDEWEB)

    Esterly, Sean; Baring-Gould, Ian; Booth, Samuel

    2017-05-04

    To address the root challenges of providing quality power to remote consumers through financially viable mini-grids, the Global Lighting and Energy Access Partnership (Global LEAP) initiative of the Clean Energy Ministerial and the U.S. Department of Energy teamed with the National Renewable Energy Laboratory (NREL) and Power Africa to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The framework addresses both alternating current (AC) and direct current (DC) mini-grids, and is applicable to renewable, fossil-fuel, and hybrid systems.

  4. Anti-glaucoma potential of Heliotropium indicum Linn in experimentally-induced glaucoma.

    Science.gov (United States)

    Kyei, Samuel; Koffuor, George Asumeng; Ramkissoon, Paul; Owusu-Afriyie, Osei

    2015-01-01

    Heliotropium indicum is used as a traditional remedy for hypertension in Ghana. The aim of the study was to evaluate the anti-glaucoma potential of an aqueous whole plant extract of H. indicum to manage experimentally-induced glaucoma. The percentage change in intraocular pressure (IOP), after inducing acute glaucoma (15 mLkg(-1) of 5 % dextrose, i.v.), in New Zealand White rabbits pretreated with Heliotropium indicum aqueous extract (HIE) (30-300 mgkg(-1)), acetazolamide (5 mgkg(-1)), and normal saline (10 mLkg(-1)) per os were measured. IOPs were also monitored in chronic glaucoma in rabbits (induced by 1 % prednisolone acetate drops, 12 hourly for 21 days) after treatments with the same doses of HIE, acetazolamide, and normal saline for 2 weeks. The anti-oxidant property of the extract was assessed by assaying for glutathione levels in the aqueous humour. Glutamate concentration in the vitreous humour was also determined using ELISA technique. Histopathological assessment of the ciliary bodies was made. The extract significantly reduced intraocular pressure (p ≤ 0.05-0.001) in acute and chronic glaucoma, preserved glutathione levels and glutamate concentration (p ≤ 0.01-0.001). Histological assessment of the ciliary body showed a decrease in inflammatory infiltration in the extract and acetazolamide-treated group compared with the normal saline-treated group. The aqueous whole plant extract of Heliotropium indicum has ocular hypotensive, anti-oxidant and possible neuro-protective effects, which therefore underscore its plausible utility as an anti-glaucoma drug with further investigation.

  5. Effect of phacoemulsification on intraocular pressure in patients with primary open angle glaucoma and pseudoexfoliation glaucoma

    Directory of Open Access Journals (Sweden)

    Jesus Jimenez-Roman

    2017-09-01

    Full Text Available AIM: To compare the effect of phacoemulsification on intraocular pressure (IOP in patients with primary open angle glaucoma (POAG and pseudoexfoliation glaucoma (PXG. METHODS: A retrospective comparative case series conducted at the Glaucoma Department at the Association to Prevent Blindness in Mexico. The study enrolled consecutive patients having phacoemulsification with intraocular lens (IOL implantation and a diagnosis of POAG or PXG. Data about IOP values and number of glaucoma medications used was collected at baseline, 1, 3, 6 and 12mo postoperatively. RESULTS: The study enrolled 88 patients (88 eyes. After phacoemulsification, there was a statistically significant reduction in IOP values and glaucoma medications use compared to baseline in both POAG and PXG patients (P<0.001. In the POAG group, a 20% decrease in IOP values was evidenced, and a 56.5% reduction in the number of medications used at the one-year follow-up. The PXG group showed a 20.39%, and a 34.46% decrease in IOP and number of medications used, respectively. A significant difference in the mean ΔIOP (postoperative changes in IOP was evidenced between groups (P=0.005. The reduction of the postsurgical IOP mean values in both groups, the POAG group showed a greater reduction in IOP values compared to the PXG group. CONCLUSION: In both types of glaucoma, phacoemulsification cataract surgery can result in a significant IOP reduction (20% over a 12mo follow-up period. The number of medications used is also significantly reduced up to 12mo after surgery, especially in the PXG group.

  6. Surgical outcomes of trabeculectomy and glaucoma drainage implant for uveitic glaucoma and relationship with uveitis activity.

    Science.gov (United States)

    Kwon, Hye Jin; Kong, Yu Xiang George; Tao, Lingwei William; Lim, Lyndell L; Martin, Keith R; Green, Catherine; Ruddle, Jonathan; Crowston, Jonathan G

    2017-07-01

    This study provides ophthalmologists who manage uveitic glaucoma with important information on factors that can affect the success of surgical management of this challenging disease. This study examines surgical outcomes of trabeculectomy and glaucoma device implant (GDI) surgery for uveitic glaucoma, in particular the effect of uveitis activity on surgical outcomes. Retrospective chart review at a tertiary institution. Eighty-two cases with uveitic glaucoma (54 trabeculectomies and 28 (GDI) surgeries) performed between 1 December 2006 and 30 November 2014. Associations of factors with surgical outcomes were examined using univariate and multivariate analysis. Surgical outcomes as defined in Guidelines from World Glaucoma Association. Average follow up was 26.4 ± 21.5 months. Overall qualified success rate of the trabeculectomies was not statistically different from GDI, being 67% and 75%, respectively (P = 0.60). Primary and secondary GDI operations showed similar success rates. The most common postoperative complication was hypotony (~30%). Active uveitis at the time of operation was higher in trabeculectomy compared with GDI group (35% vs. 14%). Active uveitis at the time of surgery did not significantly increase risk of failure for trabeculectomies. Recurrence of uveitis was significantly associated with surgical failure in trabeculectomy group (odds ratio 4.8, P = 0.02) but not in GDI group. Surgical success rate of GDI was not significantly different from trabeculectomy for uveitic glaucoma in this study. Regular monitoring, early and prolonged intensive treatment of ocular inflammation is important for surgical success particularly following trabeculectomy. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  7. Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat

    2016-10-01

    To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.

  8. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  9. Glaucoma in Costa Rica: Initial approaches

    Directory of Open Access Journals (Sweden)

    Gabriela Chavarría-Soley

    2004-09-01

    Full Text Available Glaucoma is the second most frequent cause of irreversible blindness worldwide. Genetic factors have been implicated in the development of the disease. So far six loci (GLC1A-GLC1F and two genes (TIGR/MYOC and OPTN are involved in the development of juvenile (JOAG and adult onset or chronic primary open angle glaucoma (COAG, while two loci (GLC3A,GLC3B and one gene (CYP1B1 are known for primary congenital glaucoma (PCG. Here we summarize the results of the first genetic studies of glaucoma in Costa Rica. Nine families: 1 with JOAG, 1 with PCG and 7 with COAG were screened for mutations at the known genes. A10 bp duplication, 1546-1555dupTCATGCCACC, at the CYP1B1 gene, causes, in homozygous state, glaucoma in the consanguineous PCG family. This mutation has been found in different countries and generates an early stop codon that termitates protein synthesis 140 amino acids earlier than the normal allele. In exon 1 of the TIGR/MYOC the innocuous Arg76Lys variant was found in two of the COAG families. In the OPTN gene two variants in the coding region (Thr34Thr, Met 98Lys and 7 intronic changes were found in other Costa Rican glaucoma patients. One of the COAG families was chosen for a genome scan with 379 microsatellite markers and linkage analysis. LOD scores "suggestive" of linkage were obtained for several chromosomal regions. Evidence indicates that hereditary glaucoma in Costa Rica is highly heterogeneous and that further studies in the country will probably disclose some up to now unknown genes responsible for the disease. Rev. Biol. Trop. 52(3: 507-520. Epub 2004 Dic 15.El glaucoma es la segunda causa de ceguera irreversible en el mundo. El componente genético de algunos de los distintos tipos ha sido demostrado: seis loci (GLC1A-GLC1F y dos genes (TIGR/MYOC y OPTN se conocen, hasta ahora, como responsables de la aparición de glaucomas primarios de ángulo abierto tanto del tipo juvenil (JOAG como de l tipo de adultos (COAG. Además, dos

  10. Automatic CDR Estimation for Early Glaucoma Diagnosis

    Science.gov (United States)

    Sarmiento, A.; Sanchez-Morillo, D.; Jiménez, S.; Alemany, P.

    2017-01-01

    Glaucoma is a degenerative disease that constitutes the second cause of blindness in developed countries. Although it cannot be cured, its progression can be prevented through early diagnosis. In this paper, we propose a new algorithm for automatic glaucoma diagnosis based on retinal colour images. We focus on capturing the inherent colour changes of optic disc (OD) and cup borders by computing several colour derivatives in CIE L∗a∗b∗ colour space with CIE94 colour distance. In addition, we consider spatial information retaining these colour derivatives and the original CIE L∗a∗b∗ values of the pixel and adding other characteristics such as its distance to the OD centre. The proposed strategy is robust due to a simple structure that does not need neither initial segmentation nor removal of the vascular tree or detection of vessel bends. The method has been extensively validated with two datasets (one public and one private), each one comprising 60 images of high variability of appearances. Achieved class-wise-averaged accuracy of 95.02% and 81.19% demonstrates that this automated approach could support physicians in the diagnosis of glaucoma in its early stage, and therefore, it could be seen as an opportunity for developing low-cost solutions for mass screening programs. PMID:29279773

  11. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.

    Science.gov (United States)

    Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg

    2015-01-01

    Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.

  12. Shunted Piezoelectric Vibration Damping Analysis Including Centrifugal Loading Effects

    Science.gov (United States)

    Min, James B.; Duffy, Kirsten P.; Provenza, Andrew J.

    2011-01-01

    Excessive vibration of turbomachinery blades causes high cycle fatigue problems which require damping treatments to mitigate vibration levels. One method is the use of piezoelectric materials as passive or active dampers. Based on the technical challenges and requirements learned from previous turbomachinery rotor blades research, an effort has been made to investigate the effectiveness of a shunted piezoelectric for the turbomachinery rotor blades vibration control, specifically for a condition with centrifugal rotation. While ample research has been performed on the use of a piezoelectric material with electric circuits to attempt to control the structural vibration damping, very little study has been done regarding rotational effects. The present study attempts to fill this void. Specifically, the objectives of this study are: (a) to create and analyze finite element models for harmonic forced response vibration analysis coupled with shunted piezoelectric circuits for engine blade operational conditions, (b) to validate the experimental test approaches with numerical results and vice versa, and (c) to establish a numerical modeling capability for vibration control using shunted piezoelectric circuits under rotation. Study has focused on a resonant damping control using shunted piezoelectric patches on plate specimens. Tests and analyses were performed for both non-spinning and spinning conditions. The finite element (FE) shunted piezoelectric circuit damping simulations were performed using the ANSYS Multiphysics code for the resistive and inductive circuit piezoelectric simulations of both conditions. The FE results showed a good correlation with experimental test results. Tests and analyses of shunted piezoelectric damping control, demonstrating with plate specimens, show a great potential to reduce blade vibrations under centrifugal loading.

  13. Percutaneous gastrostomy tube placement in patients with ventriculoperitoneal shunts

    Energy Technology Data Exchange (ETDEWEB)

    Sane, S.S.; Towbin, A.; Bergey, E.A.; Kaye, R.D.; Fitz, C.R.; Albright, L.; Towbin, R.B. [Department of Radiology, Children`s Hospital of Pittsburgh, 3705 Fifth Avenue, Pittsburgh, PA 15213 (United States)

    1998-07-01

    Objective. The purpose of this study is to determine the risk of CNS and/or peritoneal infection in children with ventriculoperitoneal shunts in whom a percutaneous gastrostomy tube is placed. Materials and methods. We placed 205 gastrostomy or gastrojejunostomy tubes from January of 1991 to December 1996. Twenty-three patients (10 boys, 13 girls) had ventriculoperitoneal shunts at the time of placement. All shunts were placed at least 1 month prior to placement of the gastrostomy tube. The patients ranged in age from 8 months to 16 years with a mean age of 6 years, 9 months. Patient weight ranged from 2 kg to 60 kg. All 23 children required long-term nutritional support due to severe neurologic impairment. No prophylactic antibiotics were given prior to the procedure. Of the patients, 21/23 had a 14-F Sacks-Vine gastrostomy tube with a fixed terminal retention device inserted, using percutaneous fluoroscopic antegrade technique. Two of the 23 patients had a Ross 14-F Flexi-flo gastrostomy tube which required a retrograde technique due to a small caliber esophagus in these children. Results. All 23 children had technically successful placements of percutaneous gastrostomy (7) or gastrojejunostomy (16) tubes. Of the children, 21/23 (91 %) had no complications from the procedure. Two of 23 (9 %) patients demonstrated signs of peritonitis after placement of their gastrostomy tubes and subsequently had shunt infections. In both, children CSF culture grew gram-positive cocci. The antegrade technique was used in both children who developed peritonitis. Conclusion. Our study indicates children with ventriculoperitoneal shunts who undergo percutaneous gastrostomy are at greater risk for infection and subsequent shunt malfunction. Therefore, we recommend prophylactic antibiotic therapy to cover for skin and oral flora. (orig.) With 1 fig., 7 refs.

  14. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Directory of Open Access Journals (Sweden)

    Huang J

    2015-06-01

    Full Text Available Jingjing Huang,1 Jialiu Lin,1 Ziqiang Wu,2 Hongzhi Xu,3 Chengguo Zuo,1 Jian Ge1 1State Key Laboratory of Ophthalmology, Department of Glaucoma, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People’s Republic of China; 2Center for Advanced Eye Care, Carson City, NV, USA; 3Institute of Child Health Policy, University of Florida, Gainesville, FL, USA Purpose: The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries.Patients and methods: Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1 intraocular pressure (IOP ≥6 and ≤21 mmHg; 2 IOP reduction of at least 30% relative to preoperative values; and 3 without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications.Results: Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80 mm, corneal diameter was 14.71±1.07 (13.0–16.0 mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0, and IOP was 39.5±5.7 (30–55 mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18 months. There were significant reductions in IOPs and the number of glaucoma medications (P<0.001 postoperatively. The IOPs after operation were 11.3±3.4, 13.6±5.1, 16.3±2.7, and 16.1±2.6 mmHg at 1 month, 6 months, 12 months, and 18 months, respectively. Kaplan–Meier estimates of the cumulative probability of valve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28

  15. Supra-Tenon Capsule Implantation of the Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma.

    Science.gov (United States)

    Elhefney, Eman M; Al-Sharkawy, Hossam T; Kishk, Hanem M

    2016-09-01

    To evaluate the efficacy of supra-Tenon capsule implantation of an Ahmed glaucoma valve (AGV) as a measure to decrease the fibrotic potential of the Tenon capsule on bleb formation and its subsequent effect on intraocular pressure (IOP) control in children with refractory glaucoma. Mansoura Ophthalmic Centre, Faculty of Medicine, Mansoura University, Egypt. A prospective interventional study. Twenty-two eyes of 12 children with refractory glaucoma underwent supra-Tenon capsule implantation of AGV. Ophthalmic examinations under general anesthesia including measurement of the corneal diameter and the IOP with Perkin's tonometer were performed preoperatively, on the first postoperative day, the first postoperative week, weekly for the first month, 2-weekly for the following 3 months, and monthly for at least 18 months. Postoperative complications and the number of glaucoma medications used preoperatively and postoperatively were recorded. The paired Student t test was used to compare preoperative and postoperative data. There were 12 eyes (54.6%) with refractory congenital glaucoma, 7 eyes (31.8%) with refractory pseudophakic glaucoma, and 3 eyes (13.6%) with refractory aphakic glaucoma. Patients included 10 male (83.3%) and 2 female (16.7%) children with a mean age of 16.3±9.7 months. The mean follow-up duration was 24.1±4.3 months. There was a statistically significant difference between the mean preoperative IOP (30.7±2.88 mm Hg) and the mean postoperative IOP (16.1±3.60 mm Hg) (t=16.22 and P=0.000, with a mean decrease in the IOP by 47.6%). The difference between the mean number of antiglaucoma medications before surgery (1.86±0.4) and after surgery (1.0±0.9) was also statistically significant (t=4.31 and P=0.000). Total success was achieved in 18 eyes (81.9%). Postoperative complications included tube exposure and slippage (10%), hypotony (10%), and hyphema (5%). Supra-Tenon capsule implantation of the AGV was successful in controlling the IOP with few

  16. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yang Min [Sejong General Hospital, Bucheon (Korea, Republic of)

    2006-08-15

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 {+-} 0.50 by radionuclide, and 1.74 {+-} 0.51 by oxymetry. The overall correlation coefficient was 0.86 ({rho} 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

  17. Measurement of shunt amount using radionuclide angiocardiography: accuracy according to level of shunt and associated lesion

    International Nuclear Information System (INIS)

    Kim, Yang Min

    2006-01-01

    Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. The mean Qp/Qs was 1.83 ± 0.50 by radionuclide, and 1.74 ± 0.51 by oxymetry. The overall correlation coefficient was 0.86 (ρ 0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44 and Bland-Altman range was 1.52, 0.74, 0.96, 1.57 and 1.50, respectively. There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably

  18. Isolation and characterization of Salmonella typhimurium glyoxylate shunt mutants.

    OpenAIRE

    Wilson, R B; Maloy, S R

    1987-01-01

    Growth of Salmonella typhimurium on acetate as a sole carbon source requires expression of the glyoxylate shunt; however, the genes for the glyoxylate shunt enzymes have not been previously identified in S. typhimurium. In this study, we isolated transposon insertions in the genes for the two unique enzymes of this pathway, aceA (isocitrate lyase) and aceB (malate synthase). The aceA and aceB genes were located at 89.5 min on the S. typhimurium genetic map. Genetic linkage to nearby loci indi...

  19. Controversy about Management of Hydrocephalus - Shunt vs. Endoscopic Third Ventriculostomy.

    Science.gov (United States)

    Kumar, Vikas; Bodeliwala, Shaam; Singh, Daljit

    2017-08-01

    The best management of hydrocephalus is still controversial in the twenty-first century. Shunt treatment for hydrocephalus is the most common procedure performed in neurosurgical practice and is associated with the highest complications rate. But during the last 2 decades, the treatment of hydrocephalus has improved with better shunt devices available today, increased facilities for investigations and newer approaches like endoscopic third ventriculostomy. The recent advances in development of better endoscopes have provided the patient and treating doctor with an option for an alternative surgery for treatment of hydrocephalus.

  20. Cryptococcal cerebrospinal fluid shunt infection treated with fluconazole

    Directory of Open Access Journals (Sweden)

    Daniel Eymard

    1993-01-01

    Full Text Available A 37-year-old woman with a cadaveric renal allotransplantation required intra-cranial shunting devices after a presumptive episode of tuberculous meningitis. Six months later, she developed a culture-proven cryptococcal meningitis. Without having her ventriculo-auricular shunt removed, she was successfully treated with a short course of amphotericin B (335 mg and flucytosine (nine days followed by prolonged therapy with oral fluconazole (400 mg daily for 72 days. Three years post treatment she had no evidence of relapse, and normal renal graft function.

  1. New and improved ways to treat hydrocephalus: Pursuit of a smart shunt.

    Science.gov (United States)

    Lutz, Barry R; Venkataraman, Pranav; Browd, Samuel R

    2013-01-01

    The most common treatment for hydrocephalus is placement of a cerebrospinal fluid shunt to supplement or replace lost drainage capacity. Shunts are life-saving devices but are notorious for high failure rates, difficulty of diagnosing failure, and limited control options. Shunt designs have changed little since their introduction in 1950s, and the few changes introduced have had little to no impact on these long-standing problems. For decades, the community has envisioned a "smart shunt" that could provide advanced control, diagnostics, and communication based on implanted sensors, feedback control, and telemetry. The most emphasized contribution of smart shunts is the potential for advanced control algorithms, such as weaning from shunt dependency and personalized control. With sensor-based control comes the opportunity to provide data to the physician on patient condition and shunt function, perhaps even by a smart phone. An often ignored but highly valuable contribution would be designs that correct the high failure rates of existing shunts. Despite the long history and increasing development activity in the past decade, patients are yet to see a commercialized smart shunt. Most smart shunt development focuses on concepts or on isolated technical features, but successful smart shunt designs will be a balance between technical feasibility, economic viability, and acceptable regulatory risk. Here, we present the status of this effort and a framework for understanding the challenges and opportunities that will guide introduction of smart shunts into patient care.

  2. Successful Embolization of a Spontaneous Mesocaval Shunt Using the Amplatzer Vascular Plug II

    International Nuclear Information System (INIS)

    Boixadera, Helena; Tomasello, Alejandro; Quiroga, Sergi; Cordoba, Joan; Perez, Mercedes; Segarra, Antoni

    2010-01-01

    A 48-year-old man with alcoholic liver cirrhosis and hepatic encephalopathy was found to have a large, spontaneous mesocaval shunt. The shunt was successfully occluded with the use of an Amplatzer Vascular Plug. To our knowledge, this is the first report of the use of this device to embolize a mesocaval shunt involving the superior mesenteric vein.

  3. Posthemorrhagic Hydrocephalus in Newborns: Clinical Characteristics and Role of Ventriculoperitoneal Shunts

    Directory of Open Access Journals (Sweden)

    Inn-Chi Lee

    2009-02-01

    Conclusion: Patients who were shunt-dependent had worse neurodevelopmental outcomes and greater mortality than those without shunts. The results appeared to depend on how far the hydrocephalus had progressed and on the degree of IVH, but the necessity of VP shunts requires reevaluation before they are implanted.

  4. Shoulder tip pain: an under-reported complication of ventriculoperitoneal shunt.

    LENUS (Irish Health Repository)

    Lim, C

    2012-02-03

    Ventriculoperitoneal (VP) shunt insertion is the commonest form of treatment for hydrocephalus. Shoulder tip pain after VP shunt insertion is unusual and has only recently been reported. We present a case of excruciating shoulder tip pain due to diaphragmatic irritation after VP shunt insertion.

  5. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  6. Psychometric properties of a sign language version of the Mini International Neuropsychiatric Interview (MINI)

    OpenAIRE

    Øhre, Beate; Saltnes, Hege; von Tetzchner, Stephen; Falkum, Erik

    2014-01-01

    Background There is a need for psychiatric assessment instruments that enable reliable diagnoses in persons with hearing loss who have sign language as their primary language. The objective of this study was to assess the validity of the Norwegian Sign Language (NSL) version of the Mini International Neuropsychiatric Interview (MINI). Methods The MINI was translated into NSL. Forty-one signing patients consecutively referred to two specialised psychiatric units were assessed with a diagnos...

  7. Spurious RF signals emitted by mini-UAVs

    NARCIS (Netherlands)

    Schleijpen, R.; Voogt, V.; Zwamborn, P.; Oever, J. van den

    2016-01-01

    This paper presents experimental work on the detection of spurious RF emissions of mini Unmanned Aerial Vehicles (mini-UAV). Many recent events have shown that mini-UAVs can be considered as a potential threat for civil security. For this reason the detection of mini-UAVs has become of interest to

  8. Caracterización del glaucoma juvenil

    Directory of Open Access Journals (Sweden)

    Silvia Roche Caso

    2011-03-01

    Full Text Available INTRODUCCIÓN. El glaucoma no es frecuente en los niños, pero cuando ocurre sus síntomas son poco perceptibles y produce graves consecuencias para la salud visual. El objetivo de este estudio fue caracterizar, desde las aristas clínica y epidemiológica, a los pacientes con glaucoma juvenil atendidos en los servicios de oftalmología de los Hospitales Pediátricos del Cerro y «Pedro Borrás», en Ciudad de La Habana, en el período comprendido entre enero de 2008 y diciembre de 2009. MÉTODOS. Se realizó un estudio epidemiológico longitudinal y prospectivo, cuyo universo estuvo constituido por 176 pacientes entre 5 y 18 años de edad, con presunto glaucoma. La muestra, después de aplicados los criterios de inclusión y exclusión, quedó conformada por 38 casos. Se analizaron las variables: edad al momento del diagnóstico, sexo, color de la piel, antecedentes familiares según grado de parentesco, agudeza visual máxima corregida, tipo de defecto refractivo, características del ángulo camerular, espesor corneal central, valor de la presión intraocular, alteraciones fundoscópicas y campimétricas. RESULTADOS. En la mayoría de los pacientes el diagnóstico de glaucoma juvenil constituyó un hallazgo. La mediana de edad al momento del diagnóstico fue de 12,5 años, con ligero predominio de varones y de la piel no blanca. Fue más frecuente el antecedente de glaucoma en familiares de segundo grado de consanguinidad. La mayoría de los casos tenía visión óptima, algún grado de miopía y ángulo abierto sin alteraciones evidentes del ángulo camerular, entre las cuales la más frecuente fue la presencia de procesos iridianos prominentes. CONCLUSIONES. Predominaron la disminución moderada del espesor corneal y valores medios de presión intraocular de 26,91 mm Hg. La alteración fundoscópica encontrada con mayor frecuencia fue la excavación papilar moderada (entre 0,4 y 0,5 y como lesión campimétrica, el aumento de la mancha

  9. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  10. The impact of available anti-glaucoma therapy on the volume and age profile of patients undergoing glaucoma filtration surgery.

    LENUS (Irish Health Repository)

    Keane, P A

    2012-02-01

    PURPOSE: To investigate whether new classes of glaucoma medication have influenced glaucoma filtration surgery over a 20-year period in the southeast region of Ireland. METHODS: All patients undergoing glaucoma filtration surgery between January 1986 and December 2005 in Waterford Regional Hospital were identified. The following data were recorded for each patient: age; sex; and type of filtration procedure. RESULTS: Over the 20-year study period two consultant ophthalmic surgeons performed a total of 760 glaucoma filtration procedures on patients aged over 20 years. The annual average number of glaucoma surgeries declined steadily, defined by availability of different topical anti-glaucoma medications, from an average of 23.75 surgeries per surgeon per year in the subperiod 1986-1995, to 21 in 1996, 20 in 1997, and 12.69 surgeries per surgeon per year in 1998-2005, these differences being statistically significant (general linear model, P<0.001). The age profile of patients did not change significantly over the course of the study period. CONCLUSIONS: The volume of patients requiring glaucoma filtration surgery under the care of two consultant ophthalmic surgeons decreased over the 20-year study period, an era in which three classes of anti-glaucoma medications were made available. However, an increase in the age profile of patients undergoing glaucoma filtration surgery during the same period was not observed. Further study is required to resolve whether introduction of the new topical anti-glaucoma medications has led to a real reduction in the demand for glaucoma filtration surgery, or has just led to the deferral of such a demand.

  11. Costs of a community-based glaucoma detection programme: analysis of the Philadelphia Glaucoma Detection and Treatment Project.

    Science.gov (United States)

    Pizzi, Laura T; Waisbourd, Michael; Hark, Lisa; Sembhi, Harjeet; Lee, Paul; Crews, John E; Saaddine, Jinan B; Steele, Deon; Katz, L Jay

    2018-02-01

    Glaucoma is the foremost cause of irreversible blindness, and more than 50% of cases remain undiagnosed. Our objective was to report the costs of a glaucoma detection programme operationalised through Philadelphia community centres. The analysis was performed using a healthcare system perspective in 2013 US dollars. Costs of examination and educational workshops were captured. Measures were total programme costs, cost/case of glaucoma detected and cost/case of any ocular disease detected (including glaucoma). Diagnoses are reported at the individual level (therefore representing a diagnosis made in one or both eyes). Staff time was captured during site visits to 15 of 43 sites and included time to deliver examinations and workshops, supervision, training and travel. Staff time was converted to costs by applying wage and fringe benefit costs from the US Bureau of Labor Statistics. Non-staff costs (equipment and mileage) were collected using study logs. Participants with previously diagnosed glaucoma were excluded. 1649 participants were examined. Mean total per-participant examination time was 56 min (SD 4). Mean total examination cost/participant was $139. The cost/case of glaucoma newly identified (open-angle glaucoma, angle-closure glaucoma, glaucoma suspect, or primary angle closure) was $420 and cost/case for any ocular disease identified was $273. Glaucoma examinations delivered through this programme provided significant health benefit to hard-to-reach communities. On a per-person basis, examinations were fairly low cost, though opportunities exist to improve efficiency. Findings serve as an important benchmark for planning future community-based glaucoma examination programmes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. MINI-SLAR delivery system

    International Nuclear Information System (INIS)

    Alstein, D.

    1996-01-01

    In the Spring of 1993, a need to complete Spacer Location and Repositioning (SLAR) on the Bruce 'A', Unit 1 Reactor was identified. An alternate SLAR delivery system was required due to conversion constraints that prevented the existing Bruce SLAR System from being used in Unit 1. A Portable SLAR Delivery System called MINI-SLAR Delivery System was developed, designed and fabricated in a 14 month period, then used to successfully SLAR 109 channels. The system is a portable remotely operated Nuclear Class 1 registered fitting that is independent of the Fuelling Machine, allowing the station to continue normal Fuelling and Maintenance activities. It is designed to a Level 'D' faulted condition of HPECI Pressure thus minimizing PHT Heat Sink configuration requirements and minimizing outage set-up times. The system is based on a modular design allowing for easy fabrication, assembly and repair. It consists of a Snout Assembly, a Closure Plug Assembly, Shield Plug Assembly, SLAR Ram assembly, Work Table Assembly and Control Panel. Controls are through a Programmable Logic Controller with software tested and certified to a Software Quality Assurance of Level Ill. (author). 2 refs., 2 figs

  13. MINI-SLAR delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Alstein, D [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A; Dalton, K [Spectrum Engineering, Peterborough, ON (Canada)

    1997-12-31

    In the Spring of 1993, a need to complete Spacer Location and Repositioning (SLAR) on the Bruce `A`, Unit 1 Reactor was identified. An alternate SLAR delivery system was required due to conversion constraints that prevented the existing Bruce SLAR System from being used in Unit 1. A Portable SLAR Delivery System called MINI-SLAR Delivery System was developed, designed and fabricated in a 14 month period, then used to successfully SLAR 109 channels. The system is a portable remotely operated Nuclear Class 1 registered fitting that is independent of the Fuelling Machine, allowing the station to continue normal Fuelling and Maintenance activities. It is designed to a Level `D` faulted condition of HPECI Pressure thus minimizing PHT Heat Sink configuration requirements and minimizing outage set-up times. The system is based on a modular design allowing for easy fabrication, assembly and repair. It consists of a Snout Assembly, a Closure Plug Assembly, Shield Plug Assembly, SLAR Ram assembly, Work Table Assembly and Control Panel. Controls are through a Programmable Logic Controller with software tested and certified to a Software Quality Assurance of Level Ill. (author). 2 refs., 2 figs.

  14. Latanoprost systemic exposure in pediatric and adult patients with glaucoma

    DEFF Research Database (Denmark)

    Raber, Susan; Courtney, Rachel; Maeda-Chubachi, Tomoko

    2011-01-01

    To evaluate short-term safety and steady-state systemic pharmacokinetics (PK) of latanoprost acid in pediatric subjects with glaucoma or ocular hypertension who received the adult latanoprost dose.......To evaluate short-term safety and steady-state systemic pharmacokinetics (PK) of latanoprost acid in pediatric subjects with glaucoma or ocular hypertension who received the adult latanoprost dose....

  15. Some diagnostic and therapeutic controversies in glaucoma addressed

    NARCIS (Netherlands)

    Müskens, Rogier Peter Hendrik Maria

    2008-01-01

    In the five studies contained in this thesis, several controversies on the diagnosis of and therapy for glaucoma have been addressed. The first part of this thesis consisted of three studies that aimed tot improve existing technologies for diagnosing glaucoma. The latter part consisted of two

  16. Traumatic glaucoma with features of unilateral pigment dispersion.

    Science.gov (United States)

    Bowler, Gordon; Ellul, Antony; Gouws, Pieter

    2014-01-01

    We report a patient with traumatic glaucoma with features of unilateral pigment dispersion. This rare form of secondary glaucoma has only been reported twice previously, with both patients demonstrating angle recession, indicating associated damage to the trabecular meshwork. To our knowledge, this is the first such case reported in which angle recession was absent.

  17. Clinical Features of Primary Glaucoma in South East Nigeria ...

    African Journals Online (AJOL)

    Background: The clinical course of glaucoma depends on the type, onset, severity and response to treatment. The intraocular pressure and heredity also play a role in its presentation as members of the same family tend to have the same type of glaucoma. This paper seeks to address the problem of primary open angle ...

  18. Are Ducted Mini-Splits Worth It?

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Jonathan M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Maguire, Jeffrey B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Metzger, Cheryn E. [Pacific Northwest National Laboratory; Zhang, Jason [Pacific Northwest National Laboratory

    2018-02-01

    Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

  19. Frontoplastia mini-invasiva Mini-invasive forehead-plasty

    Directory of Open Access Journals (Sweden)

    A. Fuente del Campo

    2009-06-01

    Full Text Available Una de las causas mas importantes de la flacidez y caída de la piel y de las partes blandas de la cara es la disminución del volumen de su estructura esquelética. Un factor fundamental en la restauración del envejecimiento facial seria el poder recuperar este volumen. Dado que en la actualidad no se cuenta con un recurso efectivo para recuperar el volumen óseo, lo indicado es restaurar la relación entre las partes blandas y el volumen óseo vigente. Esta es la meta mas importante de la ritidectomía subperióstica. Con una vasta experiencia en este método y buscando minimizar las cicatrices resultantes, hemos desarrollado el enfoque mini-invasivo de este procedimiento de restauración facial. En el presente trabajo describimos la aplicación de nuestro procedimiento para la restauración de la región frontal. Desde 1998 hemos realizado este procedimiento, con diversas combinaciones y variantes y dependiendo de las necesidades de cada caso, en un total de 521 pacientes: 419 mujeres y 102 hombres de edades comprendidas entre los 45 y los 73 años. Planteamos las metas y describimos los medios para realizar este procedimiento por vía frontal, transpalpebral y combinando ambas vías, a la vez que damos orientación para lograr los objetivos del procedimiento y evitar complicaciones basándonos en la Anatomía Quirúrgica. Referimos los procedimientos auxiliares que se pueden asociar a este método y describimos los detalles del manejo postoperatorio. Los resultados obtenidos han sido en general muy satisfactorios tanto para los pacientes como para el cirujano. Mencionamos también las complicaciones observadas. En conclusión, describimos las observaciones resultantes de nuestra experiencia con este método a lo largo de 10 años, con resultados tan buenos o mejores que con la ritidectomía subperióstica abierta y el porqué es actualmente nuestro procedimiento de elección.The reduction of the bony structure of the face is the main reason

  20. Shared Care in Monitoring Stable Glaucoma Patients: A Randomized Controlled Trial

    NARCIS (Netherlands)

    Holtzer-Goor, Kim M.; van Vliet, Ellen J.; van Sprundel, Esther; Plochg, Thomas; Koopmanschap, Marc A.; Klazinga, Niek S.; Lemij, Hans G.

    2016-01-01

    Comparing the quality of care provided by a hospital-based shared care glaucoma follow-up unit with care as usual. This randomized controlled trial included stable glaucoma patients and patients at risk for developing glaucoma. Patients in the Usual Care group (n=410) were seen by glaucoma

  1. Prevalence and determinants of glaucoma : an epidemiologic approach (The Rotterdam Study)

    NARCIS (Netherlands)

    I. Dielemans (Ida)

    1995-01-01

    textabstractGlaucoma is an eye disease characterized by damage to the optic nerve head and related visual field defects, often accompanied by elevated intraocular pressure. Glaucoma is an important cause of blindness, particularly in the elderly. One may divide glaucoma in primary glaucoma without

  2. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  3. [Bone remodeling and modeling/mini-modeling.

    Science.gov (United States)

    Hasegawa, Tomoka; Amizuka, Norio

    Modeling, adapting structures to loading by changing bone size and shapes, often takes place in bone of the fetal and developmental stages, while bone remodeling-replacement of old bone into new bone-is predominant in the adult stage. Modeling can be divided into macro-modeling(macroscopic modeling)and mini-modeling(microscopic modeling). In the cellular process of mini-modeling, unlike bone remodeling, bone lining cells, i.e., resting flattened osteoblasts covering bone surfaces will become active form of osteoblasts, and then, deposit new bone onto the old bone without mediating osteoclastic bone resorption. Among the drugs for osteoporotic treatment, eldecalcitol(a vitamin D3 analog)and teriparatide(human PTH[1-34])could show mini-modeling based bone formation. Histologically, mature, active form of osteoblasts are localized on the new bone induced by mini-modeling, however, only a few cell layer of preosteoblasts are formed over the newly-formed bone, and accordingly, few osteoclasts are present in the region of mini-modeling. In this review, histological characteristics of bone remodeling and modeling including mini-modeling will be introduced.

  4. MiniCNT - A Tabletop Stellarator

    Science.gov (United States)

    Dugan, Chris; Pedersen, Thomas; Berkery, John

    2006-10-01

    MiniCNT is a scaled down version of the Columbia Non-Neutral Torus, a stellarator built to study confinement of non-neutral plasmas on magnetic surfaces. MiniCNT is a glass vacuum chamber capable of holding pressures six orders of magnitude below atmospheric pressure. Unlike CNT, in which plasmas are invisible, MiniCNT allows some collisions with neutrals, causing it to glow. Using two twelve-volt car batteries to power four magnetic coils, MiniCNT generates a 0.02 Tesla magnetic field. While CNT, being larger, is obviously more accurate, there are multiple benefits in MiniCNT. First, it is more flexible and can be adjusted to fit many scenarios easily. The car batteries can be switched for other power sources, the coils can be realigned, and the chamber can be pumped to various pressures of various gases. Also, it is visually accessible; while CNT has glass viewing ports and its plasma is dark, MiniCNT is made of glass and its plasma glows, allowing visualization of the magnetic surfaces.

  5. The Psychometrics of the Mini-K.

    Science.gov (United States)

    Richardson, George B; Chen, Ching-Chen; Dai, Chia-Liang; Brubaker, Michael D; Nedelec, Joseph L

    2017-01-01

    Many published studies have employed the Mini-K to measure a single fast-slow life history dimension. However, the internal structure of the Mini-K has not been determined and it is not clear that a single higher order K-factor fits the data. It is also not clear that the Mini-K is measurement invariant across groups such as the sexes. To establish the construct validity of K as well as the broader usefulness of applying life history theory to humans, it is crucial that these psychometric issues are addressed as a part of measure validation efforts. Here we report on three studies that used latent variable modeling and data drawn from two college student samples ( ns = 361 and 300) to elucidate the psychometrics of the Mini-K. We found that (a) the Mini-K had a six dimensional first-order structure, (b) the K-factor provided a parsimonious explanation of the associations among the lower order factors at no significant cost to fit, (c) the Mini-K measured the same K-factor across the sexes, (d) K-factor means did not have the same meaning across the sexes and thus the first-order factors should be used in studies of mean sex differences, and finally, (e) the K-factor was only associated with environment and aspects of mating competition in females. Implications and future directions for life history research are discussed.

  6. Risk factors for shunt malfunction in pediatric hydrocephalus: a multicenter prospective cohort study.

    Science.gov (United States)

    Riva-Cambrin, Jay; Kestle, John R W; Holubkov, Richard; Butler, Jerry; Kulkarni, Abhaya V; Drake, James; Whitehead, William E; Wellons, John C; Shannon, Chevis N; Tamber, Mandeep S; Limbrick, David D; Rozzelle, Curtis; Browd, Samuel R; Simon, Tamara D

    2016-04-01

    OBJECT The rate of CSF shunt failure remains unacceptably high. The Hydrocephalus Clinical Research Network (HCRN) conducted a comprehensive prospective observational study of hydrocephalus management, the aim of which was to isolate specific risk factors for shunt failure. METHODS The study followed all first-time shunt insertions in children younger than 19 years at 6 HCRN centers. The HCRN Investigator Committee selected, a priori, 21 variables to be examined, including clinical, radiographic, and shunt design variables. Shunt failure was defined as shunt revision, subsequent endoscopic third ventriculostomy, or shunt infection. Important a priori-defined risk factors as well as those significant in univariate analyses were then tested for independence using multivariate Cox proportional hazard modeling. RESULTS A total of 1036 children underwent initial CSF shunt placement between April 2008 and December 2011. Of these, 344 patients experienced shunt failure, including 265 malfunctions and 79 infections. The mean and median length of follow-up for the entire cohort was 400 days and 264 days, respectively. The Cox model found that age younger than 6 months at first shunt placement (HR 1.6 [95% CI 1.1-2.1]), a cardiac comorbidity (HR 1.4 [95% CI 1.0-2.1]), and endoscopic placement (HR 1.9 [95% CI 1.2-2.9]) were independently associated with reduced shunt survival. The following had no independent associations with shunt survival: etiology, payer, center, valve design, valve programmability, the use of ultrasound or stereotactic guidance, and surgeon experience and volume. CONCLUSIONS This is the largest prospective study reported on children with CSF shunts for hydrocephalus. It confirms that a young age and the use of the endoscope are risk factors for first shunt failure and that valve type has no impact. A new risk factor-an existing cardiac comorbidity-was also associated with shunt failure.

  7. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Faraj, Walid, E-mail: wf07@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Khalife, Mohammad, E-mail: mk12@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); El-Merhi, Fadi, E-mail: fe19@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Saade, Charbel, E-mail: cs39@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Hallal, Ali, E-mail: ah05@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Haydar, Ali, E-mail: ah24@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon)

    2015-08-15

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications.

  8. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Faraj, Walid; Khalife, Mohammad; Al-Kutoubi, Aghiad; El-Merhi, Fadi; Saade, Charbel; Hallal, Ali; Haydar, Ali

    2015-01-01

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications

  9. Marijuana for Glaucoma: A Recipe for Disaster or Treatment?

    Science.gov (United States)

    Sun, Xiaoshen; Xu, Chaoying S; Chadha, Nisha; Chen, Allshine; Liu, Ji

    2015-09-01

    Marijuana has been shown to lower intraocular pressure (IOP) but with limited duration of action and numerous adverse effects. Use of marijuana to lower IOP as a means of glaucoma treatment would require frequent use throughout the day, leading to significant adverse effects, possible progression toward Cannabis Use Disorder (CUD), and/or withdrawal symptoms. The treatment of glaucoma based on the cannabis plant or drugs based on the cannabinoid molecule should be considered carefully before being prescribed. Considerations should include the adverse physical and psychological adverse effects, including substance abuse. Currently, the deleterious effects of marijuana outweigh the benefits of its IOP-lowering capacity in most glaucoma patients. Under extremely rare circumstances, a few categories of glaucoma patients may be potential candidates for treatment with medical marijuana. Further studies on alternate routes and more focused means of cannabinoid molecule delivery to the eye for glaucoma treatment are needed.

  10. No evidence of a causal relationship between hypothyroidism and glaucoma

    DEFF Research Database (Denmark)

    Thvilum, Marianne; Brandt, Frans; Brix, Thomas Heiberg

    2018-01-01

    Background An interrelationship between hypothyroidism and glaucoma, due to a shared autoimmune background or based on deposition of mucopolysaccharides in the trabecular meshwork in the eye, has been suggested but is at present unsubstantiated. Therefore, our objective was to investigate......-hypothyroid controls according to age and sex. Prevalence of glaucoma was recorded and cases and controls were followed over a mean of 7.1 years (range 0±17). Logistic and Cox regression models were used to assess the risk of glaucoma before and after the diagnosis of hypothyroidism, respectively. Results Overall, we...... found a higher prevalence of glaucoma in subjects with hypothyroidism as compared to controls (4.6% vs. 4.3%, p glaucoma [1.09; 95% confidence interval (CI): 1.04-1.13]. Based on the Cox regression...

  11. Retinal oxygen saturation before and after glaucoma surgery.

    Science.gov (United States)

    Nitta, Eri; Hirooka, Kazuyuki; Shimazaki, Takeru; Sato, Shino; Ukegawa, Kaori; Nakano, Yuki; Tsujikawa, Akitaka

    2017-08-01

    This study compared retinal vessel oxygen saturation before and after glaucoma surgery. Retinal oxygen saturation in glaucoma patients was measured using a non-invasive spectrophotometric retinal oximeter. Adequate image quality was found in 49 of the 108 consecutive glaucoma patients recruited, with 30 undergoing trabeculectomy, 11 EX-PRESS and eight trabeculotomy. Retinal oxygen saturation measurements in the retinal arterioles and venules were performed at 1 day prior to and at approximately 10 days after surgery. Statistical analysis was performed using a Student's t-test. After glaucoma surgery, intraocular pressure (IOP) decreased from 19.8 ± 7.7 mmHg to 9.0 ± 5.7 mmHg (p glaucoma surgery had an effect on the retinal venous oxygen saturation. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  12. Visual disability and quality of life in glaucoma patients.

    Science.gov (United States)

    Cesareo, Massimo; Ciuffoletti, Elena; Ricci, Federico; Missiroli, Filippo; Giuliano, Mario Alberto; Mancino, Raffaele; Nucci, Carlo

    2015-01-01

    Glaucoma is an optic neuropathy that can result in progressive and irreversible vision loss, thereby affecting quality of life (QoL) of patients. Several studies have shown a strong correlation between visual field damage and visual disability in patients with glaucoma, even in the early stages of the disease. Visual impairment due to glaucoma affects normal daily activities required for independent living, such as driving, walking, and reading. There is no generally accepted instrument for assessing quality of life in glaucoma patients; different factors involved in visual disability from the disease are difficult to quantify and not easily standardized. This chapter summarizes recent works from clinical and epidemiological studies, which describe how glaucoma affects the performance of important vision-related activities and QoL. © 2015 Elsevier B.V. All rights reserved.

  13. A Review of the Ahmed Glaucoma Valve Implant and Comparison with Other Surgical Operations.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Katsanos, Andreas; Oddone, Francesco; Quaranta, Luciano

    2017-04-01

    The Ahmed glaucoma valve (AGV) is a popular glaucoma drainage implant used for the control of intraocular pressure in patients with glaucoma. While in the past AGV implantation was reserved for glaucoma patients poorly controlled after one or more filtration procedures, mounting evidence has recently encouraged its use as a primary surgery in selected cases. AGV has been demonstrated to be safe and effective in reducing intraocular pressure in patients with primary or secondary refractory glaucoma. Compared to other glaucoma surgeries, AGV implantation has shown favorable efficacy and safety. The aim of this article is to review the results of studies directly comparing AGV with other surgical procedures in patients with glaucoma.

  14. Clinical observation of Ahmed glaucoma valve implantation for refractory glaucoma by directly puncturing the sclerotic tunnel

    Directory of Open Access Journals (Sweden)

    Zhi-Ke Xu

    2015-02-01

    Full Text Available AIM: To observe the clinic effects and complication of Ahmed glaucoma valve(AGVimplantation in refractory glaucoma by using the 23G syringe needle direct puncture the sclerotic tunnel.METHODS: Forty-four cases(44 eyesof refractory glaucoma underwent AGV implantation by useing the 23G syringe needle direct puncture the sclerotic tunnel. The intraocular pressure(IOP, visual acuity, and complication of post-operation were contrasted with those of pre-operation. RESULTS:The success rate was 84.1%, the mean preoperative IOP in research group was 52.1±10.1mmHg, and the last follow up mean IOP was 15.6±6.9mmHg. Compared with the preoperative visual acuity, 11 eyes increased, 27 eyes had no changes and 6 eyes decreased. The main post-operative complications included shallow anterior chamber(4 eyes, choroidal detachment(3 eyes, drainage tube shift(1 eye, hyphema(6 eyes, drainage tube blockage(1 eye, expulsive choroidal hemorrhage(1 eye, and fiber wrap of drainage tray(5 eyes.CONCLUSION: AGV implantation by direct puncture the sclerotic tunnel is feasible and easy. It avoids of making sclerotic petal and the xenogenic sclera transplanting, simplified the operation technique, prevent the leakage of around tube. The shallow anterior chamber rate is lower. It is an effective procedure for refractory glaucoma.

  15. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pglaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  16. Nanotechnology and glaucoma: a review of the potential implications of glaucoma nanomedicine.

    Science.gov (United States)

    Kim, Nathaniel J; Harris, Alon; Gerber, Austin; Tobe, Leslie Abrams; Amireskandari, Annahita; Huck, Andrew; Siesky, Brent

    2014-04-01

    The purpose of this review is to discuss the evolution of nanotechnology and its potential diagnostic and therapeutic applications in the field of ophthalmology, particularly as it pertains to glaucoma. We reviewed literature using MEDLINE and PubMed databases with the following search terms: glaucoma, nanotechnology, nanomedicine, nanoparticles, ophthalmology and liposomes. We also reviewed pertinent references from articles found in this search. A brief history of nanotechnology and nanomedicine will be covered, followed by a discussion of the advantages and concerns of using this technology in the field of glaucoma. We will look at various studies concerning the development of nanomedicine, its potential applications in ocular drug delivery, diagnostic and imaging modalities and, surgical techniques. In particular, the challenges of assuring safety and efficacy of nanomedicine will be examined. We conclude that nanotechnology offers a novel approach to expanding diagnostic, imaging and surgical modalities in glaucoma and may contribute to the knowledge of disease pathogenesis at a molecular level. However, more research is needed to better elucidate the mechanism of cellular entry, the potential for nanoparticle cytotoxicity and the assurance of clinical efficacy.

  17. Comparison of axial lengths in occludable angle and angle-closure glaucoma-The Bhaktapur Glaucoma Study

    NARCIS (Netherlands)

    Thapa, S.S.; Paudyal, I.; Khanal, S.; Paudel, N.; van Rens, G.H.M.B.

    2011-01-01

    Purpose. To compare the anterior chamber depth (ACD) and axial length of eyes in a population-based sample among normal, occludable angle, and primary angle-closure glaucoma (PACG) groups. Methods. Totally, 3979 subjects from a population-based glaucoma prevalence study underwent complete ocular

  18. Understanding practice patterns of glaucoma sub-specialists in India

    Directory of Open Access Journals (Sweden)

    Nikhil S. Choudhari

    2017-10-01

    Full Text Available AIM: To obtain information on the prevailing practice patterns of glaucoma specialists in India. METHODS: Glaucoma specialists attending the Annual Conference of the Glaucoma Society of India (GSI were surveyed. This survey, conducted in 2013, was based on an interactive audience response system. RESULTS: The information was obtained from 146 glaucoma specialists. Approximately half (n=83; 57% had ≥10y of experience in managing glaucoma and were in institutional practice (n=74, 51%. Goldmann applanation tonometry was preferred by 103 (72% specialists whilst n=25 (17.4% used non-contact tonometer. Indentation gonioscopy was favoured by two-thirds (n=90, 66% whereas stereoscopic optic disc examination and visual fields using Humphrey perimeter was performed by a majority of the specialists surveyed (n=115, 86% and n=114; 83% respectively. Nearly three quarter specialists (n=96; 72% preferred optical coherence tomography for imaging. The primary choice for treatment of angle closure disease and primary open angle glaucoma was laser (iridotomy, n=117; 93% and medical management (prostaglandin analogue, n=104; 78%, respectively. Approximately only a third of the specialists surveyed (n=37; 28% were performing both trabeculectomy and implantation of a glaucoma drainage device and about half (n=64; 47% were not operating on congenital glaucoma at all. CONCLUSION: This survey has found conformance with preferred practice patterns in several areas of diagnosis and management of glaucoma, but there was diversity in a few areas. The information is a significant step towards improvement of glaucoma care in India, including planning for future strategies.

  19. Shunt hybrid active power filter for harmonic mitigation: A practical ...

    Indian Academy of Sciences (India)

    shunt HAPF, APF is connected in series with PPF and the whole system is connected in parallel to the load. ... LC filter, it will force a fundamental reactive current to flow into it. ..... Since SHAPF is operating as a boost rectifier, d.c. voltage.

  20. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...